| 1 | voltageOff = function() | 
|---|
| 2 | { | 
|---|
| 3 | var state = dim.state("BIAS_CONTROL").name; | 
|---|
| 4 |  | 
|---|
| 5 | if (state=="Disconnected") | 
|---|
| 6 | { | 
|---|
| 7 | console.out("  Voltage off: bias crate disconnected!"); | 
|---|
| 8 | return; | 
|---|
| 9 | } | 
|---|
| 10 |  | 
|---|
| 11 | // check of feedback has to be switched on | 
|---|
| 12 | var isOn = state=="VoltageOn" || state=="Ramping"; | 
|---|
| 13 | if (isOn) | 
|---|
| 14 | { | 
|---|
| 15 | dim.log("Switching voltage off."); | 
|---|
| 16 |  | 
|---|
| 17 | if (dim.state("FTM_CONTROL").name=="TriggerOn") | 
|---|
| 18 | { | 
|---|
| 19 | dim.send("FTM_CONTROL/STOP_TRIGGER"); | 
|---|
| 20 | dim.wait("FTM_CONTROL", "Valid", 3000); | 
|---|
| 21 | } | 
|---|
| 22 |  | 
|---|
| 23 | // Supress the possibility that the bias control is | 
|---|
| 24 | // ramping and will reject the command to switch the | 
|---|
| 25 | // voltage off | 
|---|
| 26 | //dim.send("FEEDBACK/STOP"); | 
|---|
| 27 | //dim.wait("FEEDBACK", "Calibrated", 3000); | 
|---|
| 28 |  | 
|---|
| 29 | // Make sure we are not in Ramping anymore | 
|---|
| 30 | //dim.wait("BIAS_CONTROL", "VoltageOn", 3000); | 
|---|
| 31 |  | 
|---|
| 32 | // Switch voltage off | 
|---|
| 33 | dim.send("BIAS_CONTROL/SET_ZERO_VOLTAGE"); | 
|---|
| 34 | } | 
|---|
| 35 |  | 
|---|
| 36 | dim.wait("BIAS_CONTROL", "VoltageOff", 60000); // FIXME: 30000? | 
|---|
| 37 | dim.wait("FEEDBACK",     "Calibrated",  3000); | 
|---|
| 38 |  | 
|---|
| 39 | // FEEDBACK stays in CurrentCtrl when Voltage is off but output enabled | 
|---|
| 40 | // dim.wait("FEEDBACK", "CurrentCtrlIdle", 1000); | 
|---|
| 41 |  | 
|---|
| 42 | if (isOn) | 
|---|
| 43 | dim.log("Voltage off."); | 
|---|
| 44 | } | 
|---|
| 45 |  | 
|---|
| 46 | waitForVoltageOn = function() | 
|---|
| 47 | { | 
|---|
| 48 | // Avoid output if condition is already fulfilled | 
|---|
| 49 | dim.log("Waiting for voltage to be stable."); | 
|---|
| 50 |  | 
|---|
| 51 | function func() | 
|---|
| 52 | { | 
|---|
| 53 | if (this.ok==true) | 
|---|
| 54 | return true; | 
|---|
| 55 | } | 
|---|
| 56 |  | 
|---|
| 57 | var now = new Date(); | 
|---|
| 58 |  | 
|---|
| 59 | this.last = undefined; | 
|---|
| 60 | this.ok = false; | 
|---|
| 61 | v8.timeout(4*60000, func, this); // FIMXE: Remove 4! | 
|---|
| 62 | this.ok = undefined; | 
|---|
| 63 |  | 
|---|
| 64 | dim.log("Voltage On(?)"); | 
|---|
| 65 |  | 
|---|
| 66 | //if (irq) | 
|---|
| 67 | //dim.log("Waiting for stable voltage interrupted."); | 
|---|
| 68 | //else | 
|---|
| 69 | //dim.log("Voltage stable within limits"); | 
|---|
| 70 | } | 
|---|
| 71 |  | 
|---|
| 72 |  | 
|---|
| 73 | voltageOn = function(ov) | 
|---|
| 74 | { | 
|---|
| 75 | if (isNaN(ov)) | 
|---|
| 76 | ov = 1.1; | 
|---|
| 77 |  | 
|---|
| 78 | if (this.ov!=ov && dim.state("FEEDBACK").name=="InProgress") // FIXME: Warning, OnStandby, Critical if (ov<this.ov) | 
|---|
| 79 | { | 
|---|
| 80 | dim.log("Stoping feedback."); | 
|---|
| 81 | if (dim.state("FTM_CONTROL").name=="TriggerOn") | 
|---|
| 82 | { | 
|---|
| 83 | dim.send("FTM_CONTROL/STOP_TRIGGER"); | 
|---|
| 84 | dim.wait("FTM_CONTROL", "Valid", 3000); | 
|---|
| 85 | } | 
|---|
| 86 |  | 
|---|
| 87 | dim.send("FEEDBACK/STOP"); | 
|---|
| 88 | dim.wait("FEEDBACK", "Calibrated", 3000); | 
|---|
| 89 |  | 
|---|
| 90 | // Make sure we are not in Ramping anymore | 
|---|
| 91 | dim.wait("BIAS_CONTROL", "VoltageOn", 3000); | 
|---|
| 92 | } | 
|---|
| 93 |  | 
|---|
| 94 | var isOff = dim.state("FEEDBACK").name=="Calibrated"; | 
|---|
| 95 | if (isOff) | 
|---|
| 96 | { | 
|---|
| 97 | dim.log("Switching voltage to Uov="+ov+"V."); | 
|---|
| 98 |  | 
|---|
| 99 | dim.send("FEEDBACK/START", ov); | 
|---|
| 100 |  | 
|---|
| 101 | // FIXME: We could miss "InProgress" if it immediately changes to "Warning" | 
|---|
| 102 | //        Maybe a dim.timeout state>8 ? | 
|---|
| 103 | dim.wait("FEEDBACK", "InProgress", 45000); | 
|---|
| 104 |  | 
|---|
| 105 | this.ov = ov; | 
|---|
| 106 | } | 
|---|
| 107 |  | 
|---|
| 108 | // Wait until voltage on | 
|---|
| 109 | dim.wait("BIAS_CONTROL", "VoltageOn", 60000); // FIXME: 30000? | 
|---|
| 110 | } | 
|---|
| 111 |  | 
|---|
| 112 | dim.log("STARTING SCRIPT closed_lid_ratescan"); | 
|---|
| 113 |  | 
|---|
| 114 | // dim.log("Sending Voltage On"); | 
|---|
| 115 | // voltageOn(); | 
|---|
| 116 | v8.sleep(10000); | 
|---|
| 117 |  | 
|---|
| 118 | var tm = new Date(); | 
|---|
| 119 |  | 
|---|
| 120 | dim.log("Starting ratescan."); | 
|---|
| 121 |  | 
|---|
| 122 | // Start rate scan | 
|---|
| 123 | //dim.send("RATE_SCAN/START_THRESHOLD_SCAN", 200, 900, 20); | 
|---|
| 124 | dim.send("RATE_SCAN/START_THRESHOLD_SCAN", 100, 900, 10); | 
|---|
| 125 |  | 
|---|
| 126 | // PAUSE | 
|---|
| 127 | dim.log("PAUSE 10s"); | 
|---|
| 128 | v8.sleep(10000); | 
|---|
| 129 | dim.log("Start Ratescan"); | 
|---|
| 130 |  | 
|---|
| 131 | // Lets wait if the ratescan really starts... this might take a few | 
|---|
| 132 | dim.wait("RATE_SCAN", "InProgress", 10000); | 
|---|
| 133 | //dim.wait("RATE_SCAN", "Connected", 2700000); | 
|---|
| 134 | dim.wait("RATE_SCAN", "Connected", 3500000); | 
|---|
| 135 |  | 
|---|
| 136 | dim.log("Ratescan done"); | 
|---|
| 137 |  | 
|---|
| 138 |  | 
|---|
| 139 | // voltageOff(); | 
|---|
| 140 |  | 
|---|
| 141 | dim.log("Task finished [RATESCAN]"); | 
|---|
| 142 | console.out(""); | 
|---|
| 143 |  | 
|---|