1 | /**
|
---|
2 | * @fileOverview This file has functions related to documenting JavaScript.
|
---|
3 | * @author <a href="mailto:thomas.bretz@epfl.ch">Thomas Bretz</a>
|
---|
4 | */
|
---|
5 | 'use strict';
|
---|
6 |
|
---|
7 | dim.log("Start: "+__FILE__+" ["+__DATE__+"]");
|
---|
8 |
|
---|
9 | //dimctrl.defineState(37, "TimeOutBeforeTakingData", "MCP took more than 5minutes to start TakingData");
|
---|
10 |
|
---|
11 | // ================================================================
|
---|
12 | // Code related to the schedule
|
---|
13 | // ================================================================
|
---|
14 |
|
---|
15 | //this is just the class implementation of 'Observation'
|
---|
16 | include('scripts/Observation_class.js');
|
---|
17 |
|
---|
18 | // this file just contains the definition of
|
---|
19 | // the variable observations, which builds our nightly schedule, hence the filename
|
---|
20 | include('scripts/schedule.js');
|
---|
21 |
|
---|
22 | // make Observation objects from user input and check if 'date' is increasing.
|
---|
23 | for (var i=0; i<observations.length; i++)
|
---|
24 | {
|
---|
25 | observations[i] = new Observation(observations[i]);
|
---|
26 |
|
---|
27 | // check if the start date given by the user is increasing.
|
---|
28 | if (i>0 && observations[i].start <= observations[i-1].start)
|
---|
29 | {
|
---|
30 | throw new Error("Start time '"+ observations[i].start.toUTCString()+
|
---|
31 | "' in row "+i+" exceeds start time in row "+(i-1));
|
---|
32 | }
|
---|
33 | }
|
---|
34 |
|
---|
35 | // Get the observation scheduled for 'now' from the table and
|
---|
36 | // return its index
|
---|
37 | function getObservation(now)
|
---|
38 | {
|
---|
39 | if (now==undefined)
|
---|
40 | now = new Date();
|
---|
41 |
|
---|
42 | if (isNaN(now.valueOf()))
|
---|
43 | throw new Error("Date argument in getObservation invalid.");
|
---|
44 |
|
---|
45 | for (var i=0; i<observations.length; i++)
|
---|
46 | if (now<observations[i].start)
|
---|
47 | return i-1;
|
---|
48 |
|
---|
49 | return observations.length-1;
|
---|
50 | }
|
---|
51 |
|
---|
52 | // ================================================================
|
---|
53 | // Code to check whether observation is allowed
|
---|
54 | // ================================================================
|
---|
55 | /*
|
---|
56 | function currentEst(source)
|
---|
57 | {
|
---|
58 | var moon = new Moon();
|
---|
59 | if (!moon.isUp)
|
---|
60 | return 7.7;
|
---|
61 |
|
---|
62 | var dist = Sky.dist(moon, source);
|
---|
63 |
|
---|
64 | var alt = 90-moon.toLocal().zd;
|
---|
65 |
|
---|
66 | var lc = dist*alt*pow(Moon.disk(), 6)/360/360;
|
---|
67 |
|
---|
68 | var cur = 7.7+4942*lc;
|
---|
69 |
|
---|
70 | return cur;
|
---|
71 | }
|
---|
72 |
|
---|
73 | function thresholdEst(source) // relative threshold (ratio)
|
---|
74 | {
|
---|
75 | // Assumption:
|
---|
76 | // atmosphere is 70km, shower taks place after 60km, earth radius 6400km
|
---|
77 | // just using the cosine law
|
---|
78 | // This fits very well with MC results: See Roger Firpo, p.45
|
---|
79 | // "Study of the MAGIC telescope sensitivity for Large Zenith Angle observations"
|
---|
80 |
|
---|
81 | var c = Math.cos(Math.Pi-source.zd);
|
---|
82 | var ratio = (10*sqrt(409600*c*c+9009) + 6400*c - 60)/10;
|
---|
83 |
|
---|
84 | // assumption: Energy threshold increases linearily with current
|
---|
85 | // assumption: Energy threshold increases linearily with distance
|
---|
86 |
|
---|
87 | return ratio*currentEst(source)/7.7;
|
---|
88 | }
|
---|
89 | */
|
---|
90 |
|
---|
91 | // ----------------------------------------------------------------
|
---|
92 |
|
---|
93 | // ================================================================
|
---|
94 | // Code related to monitoring the fad system
|
---|
95 | // ================================================================
|
---|
96 |
|
---|
97 | var sub_incomplete = new Subscription("FAD_CONTROL/INCOMPLETE");
|
---|
98 |
|
---|
99 | var incomplete = 0;
|
---|
100 |
|
---|
101 | sub_incomplete.onchange = function(evt)
|
---|
102 | {
|
---|
103 | if (!evt.data)
|
---|
104 | return;
|
---|
105 |
|
---|
106 | var inc = evt.obj['incomplete'];
|
---|
107 | if (!inc || inc>0xffffffffff)
|
---|
108 | return;
|
---|
109 |
|
---|
110 | if (incomplete>0)
|
---|
111 | return;
|
---|
112 |
|
---|
113 | if (dim.state("MCP").name!="TakingData")
|
---|
114 | return;
|
---|
115 |
|
---|
116 | incomplete = inc;
|
---|
117 |
|
---|
118 | console.out("Sending MCP/STOP");
|
---|
119 | dim.send("MCP/STOP");
|
---|
120 | }
|
---|
121 |
|
---|
122 | var sub_connections = new Subscription("FAD_CONTROL/CONNECTIONS");
|
---|
123 |
|
---|
124 | /**
|
---|
125 | * call-back function of FAD_CONTROL/CONNECTIONS
|
---|
126 | * store IDs of problematic FADs
|
---|
127 | *
|
---|
128 | */
|
---|
129 | /*
|
---|
130 | sub_connections.onchange = function(evt)
|
---|
131 | {
|
---|
132 | // This happens, but why?
|
---|
133 | if (!evt.obj['status'])
|
---|
134 | return;
|
---|
135 |
|
---|
136 | this.reset = [ ];
|
---|
137 |
|
---|
138 | for (var x=0; x<40; x++)
|
---|
139 | if (evt.obj['status'][x]!=66 && evt.obj['status'][x]!=67)
|
---|
140 | this.reset.push(x);
|
---|
141 |
|
---|
142 | if (this.reset.length==0)
|
---|
143 | return;
|
---|
144 |
|
---|
145 | //m.alarm("FAD board loss detected...");
|
---|
146 | dim.send("MCP/RESET");
|
---|
147 | dim.send("FAD_CONTROL/CLOSE_OPEN_FILES");
|
---|
148 | }
|
---|
149 | */
|
---|
150 |
|
---|
151 | /**
|
---|
152 | * reconnect to problematic FADs
|
---|
153 | *
|
---|
154 | * Dis- and Reconnects to FADs, found to be problematic by call-back function
|
---|
155 | * onchange() to have a different CONNECTION value than 66 or 67.
|
---|
156 | *
|
---|
157 | * @returns
|
---|
158 | * a boolean is returned.
|
---|
159 | * reconnect returns true if:
|
---|
160 | * * nothing needed to be reset --> no problems found by onchange()
|
---|
161 | * * the reconnection went fine.
|
---|
162 | *
|
---|
163 | * reconnect *never returns false* so far.
|
---|
164 | *
|
---|
165 | * @example
|
---|
166 | * if (!sub_connections.reconnect())
|
---|
167 | * exit();
|
---|
168 | */
|
---|
169 | sub_connections.reconnect = function()
|
---|
170 | {
|
---|
171 | // this.reset is a list containing the IDs of FADs,
|
---|
172 | // which have neither CONNECTION==66 nor ==67, whatever this means :-)
|
---|
173 | if (this.reset.length==0)
|
---|
174 | return true;
|
---|
175 |
|
---|
176 | console.out(" Reconnect: start ["+this.reset.length+"]");
|
---|
177 |
|
---|
178 | for (var i=0; i<this.reset.length; i++)
|
---|
179 | dim.send("FAD_CONTROL/DISCONNECT", this.reset[i]);
|
---|
180 |
|
---|
181 | v8.sleep(3000);
|
---|
182 |
|
---|
183 | while (this.reset.length)
|
---|
184 | dim.send("FAD_CONTROL/CONNECT", this.reset.pop());
|
---|
185 |
|
---|
186 | v8.sleep(1000);
|
---|
187 | dim.wait("FAD_CONTROL", "Connected", 3000);
|
---|
188 |
|
---|
189 | console.out(" Reconnect: end");
|
---|
190 |
|
---|
191 | return true;
|
---|
192 | }
|
---|
193 |
|
---|
194 | // ================================================================
|
---|
195 | // Code related to taking data
|
---|
196 | // ================================================================
|
---|
197 |
|
---|
198 | var startrun = new Subscription("FAD_CONTROL/START_RUN");
|
---|
199 | startrun.get(5000);
|
---|
200 |
|
---|
201 | function reconnect(list, txt)
|
---|
202 | { /*
|
---|
203 | var reset = [ ];
|
---|
204 |
|
---|
205 | for (var i=0; i<list.length; i++)
|
---|
206 | {
|
---|
207 | console.out(" FAD %2d".$(list[i])+" lost during "+txt);
|
---|
208 | reset.push(parseInt(list[i]/10));
|
---|
209 | }
|
---|
210 |
|
---|
211 | reset = reset.filter(function(elem,pos){return reset.indexOf(elem)==pos;});
|
---|
212 |
|
---|
213 | console.out("");
|
---|
214 | console.out(" FADs belong to crate(s): "+reset);
|
---|
215 | console.out("");
|
---|
216 | */
|
---|
217 | console.out("");
|
---|
218 | console.out("Trying automatic reconnect ["+txt+"]...");
|
---|
219 |
|
---|
220 | for (var i=0; i<list.length; i++)
|
---|
221 | {
|
---|
222 | console.out(" ...disconnect "+list[i]);
|
---|
223 | dim.send("FAD_CONTROL/DISCONNECT", list[i]);
|
---|
224 | }
|
---|
225 |
|
---|
226 | console.out(" ...waiting for 5s");
|
---|
227 | v8.sleep(5000);
|
---|
228 |
|
---|
229 | for (var i=0; i<list.length; i++)
|
---|
230 | {
|
---|
231 | console.out(" ...reconnect "+list[i]);
|
---|
232 | dim.send("FAD_CONTROL/CONNECT", list[i]);
|
---|
233 | }
|
---|
234 |
|
---|
235 | console.out(" ...waiting for 1s");
|
---|
236 | v8.sleep(1000);
|
---|
237 | console.out("");
|
---|
238 | }
|
---|
239 |
|
---|
240 | function takeRun(type, count, time)
|
---|
241 | {
|
---|
242 | if (!count)
|
---|
243 | count = -1;
|
---|
244 | if (!time)
|
---|
245 | time = -1;
|
---|
246 |
|
---|
247 | var nextrun = startrun.get().obj['next'];
|
---|
248 | console.out(" Take run %3d".$(nextrun)+": N="+count+" T="+time+"s ["+type+"]");
|
---|
249 |
|
---|
250 | incomplete = 0;
|
---|
251 | dim.send("MCP/START", time?time:-1, count?count:-1, type);
|
---|
252 |
|
---|
253 | // FIXME: Replace by callback?
|
---|
254 | //
|
---|
255 | // DN: I believe instead of waiting for 'TakingData' one could split this
|
---|
256 | // up into two checks with an extra condition:
|
---|
257 | // if type == 'data':
|
---|
258 | // wait until ThresholdCalibration starts:
|
---|
259 | // --> this time should be pretty identical for each run
|
---|
260 | // if this takes longer than say 3s:
|
---|
261 | // there might be a problem with one/more FADs
|
---|
262 | //
|
---|
263 | // wait until "TakingData":
|
---|
264 | // --> this seems to take even some minutes sometimes...
|
---|
265 | // (might be optimized rather soon, but still in the moment...)
|
---|
266 | // if this takes way too long:
|
---|
267 | // there might be something broken,
|
---|
268 | // so maybe a very high time limit is ok here.
|
---|
269 | // I think there is not much that can go wrong,
|
---|
270 | // when the Thr-Calib has already started. Still it might be nice
|
---|
271 | // If in the future RateControl is written so to find out that
|
---|
272 | // in case the threshold finding algorithm does
|
---|
273 | // *not converge as usual*
|
---|
274 | // it can complain, and in this way give a hint, that the weather
|
---|
275 | // might be a little bit too bad.
|
---|
276 | // else:
|
---|
277 | // wait until "TakingData":
|
---|
278 | // --> in a non-data run this time should be pretty short again
|
---|
279 | // if this takes longer than say 3s:
|
---|
280 | // there might be a problem with one/more FADs
|
---|
281 | //
|
---|
282 |
|
---|
283 | // Use this if you use the rate control to calibrate by rates
|
---|
284 | //if (!dim.wait("MCP", "TakingData", -300000) )
|
---|
285 | //{
|
---|
286 | // throw new Error("MCP took longer than 5 minutes to start TakingData"+
|
---|
287 | // "maybe this idicates a problem with one of the FADs?");
|
---|
288 | //}
|
---|
289 |
|
---|
290 | // Here we could check and handle fad losses
|
---|
291 |
|
---|
292 | try
|
---|
293 | {
|
---|
294 | dim.wait("MCP", "TakingData", 15000);
|
---|
295 | }
|
---|
296 | catch (e)
|
---|
297 | {
|
---|
298 | console.out("");
|
---|
299 | console.out("MCP: "+dim.state("MCP").name);
|
---|
300 | console.out("FAD_CONTROL: "+dim.state("FAD_CONTROL").name);
|
---|
301 | console.out("FTM_CONTROL: "+dim.state("FTM_CONTROL").name);
|
---|
302 | console.out("");
|
---|
303 |
|
---|
304 | if (dim.state("MCP").name!="Configuring3" ||
|
---|
305 | dim.state("FAD_CONTROL").name!="Configuring2")
|
---|
306 | throw e;
|
---|
307 |
|
---|
308 | console.out("");
|
---|
309 | console.out("Waiting for fadctrl to get configured timed out... checking for in-run FAD loss.");
|
---|
310 |
|
---|
311 | var con = sub_connections.get();
|
---|
312 | var stat = con.obj['status'];
|
---|
313 |
|
---|
314 | console.out("Sending MCP/RESET");
|
---|
315 | dim.send("MCP/RESET");
|
---|
316 |
|
---|
317 | dim.wait("FTM_CONTROL", "Idle", 3000);
|
---|
318 | dim.wait("FAD_CONTROL", "Connected", 3000);
|
---|
319 | dim.wait("MCP", "Idle", 3000);
|
---|
320 |
|
---|
321 | /*** FOR REMOVE ***/
|
---|
322 | var reset = [ ];
|
---|
323 |
|
---|
324 | for (var i=0; i<40; i++)
|
---|
325 | if (stat[i]!=0x43)
|
---|
326 | {
|
---|
327 | console.out(" FAD %2d".$(i)+" not in Configured state.");
|
---|
328 | reset.push(parseInt(i/10));
|
---|
329 | }
|
---|
330 |
|
---|
331 | reset = reset.filter(function(elem,pos){return reset.indexOf(elem)==pos;});
|
---|
332 |
|
---|
333 | if (reset.length>0)
|
---|
334 | {
|
---|
335 | console.out("");
|
---|
336 | console.out(" FADs belong to crate(s): "+reset);
|
---|
337 | console.out("");
|
---|
338 | }
|
---|
339 | /**** FOR REMOVE ****/
|
---|
340 |
|
---|
341 | var list = [];
|
---|
342 | for (var i=0; i<40; i++)
|
---|
343 | if (stat[i]!=0x43)
|
---|
344 | list.push(i);
|
---|
345 |
|
---|
346 | reconnect(list, "configuration");
|
---|
347 |
|
---|
348 | throw e;
|
---|
349 | }
|
---|
350 |
|
---|
351 | dim.wait("MCP", "Idle", time>0 ? time*1250 : undefined); // run time plus 25%
|
---|
352 |
|
---|
353 | if (incomplete)
|
---|
354 | {
|
---|
355 | console.out("Incomplete: "+incomplete);
|
---|
356 |
|
---|
357 | console.out("");
|
---|
358 | console.out("MCP: "+dim.state("MCP").name);
|
---|
359 | console.out("FAD_CONTROL: "+dim.state("FAD_CONTROL").name);
|
---|
360 | console.out("FTM_CONTROL: "+dim.state("FTM_CONTROL").name);
|
---|
361 | console.out("");
|
---|
362 |
|
---|
363 | dim.wait("MCP", "Idle", 3000);
|
---|
364 | dim.wait("FTM_CONTROL", "Idle", 3000);
|
---|
365 |
|
---|
366 | // Necessary to allow the disconnect, reconnect
|
---|
367 | dim.send("FAD_CONTROL/CLOSE_OPEN_FILES");
|
---|
368 | dim.wait("FAD_CONTROL", "Connected", 3000);
|
---|
369 |
|
---|
370 | var list = [];
|
---|
371 | for (var i=0; i<40; i++)
|
---|
372 | if (incomplete&(1<<i))
|
---|
373 | list.push(i);
|
---|
374 |
|
---|
375 | reconnect(list, "data taking");
|
---|
376 |
|
---|
377 | throw new Error("In-run FAD loss detected.");
|
---|
378 | }
|
---|
379 |
|
---|
380 | //console.out(" Take run: end");
|
---|
381 |
|
---|
382 | // DN: currently reconnect() never returns false
|
---|
383 | // .. but it can fail of course.
|
---|
384 | //if (!sub_connections.reconnect())
|
---|
385 | // exit();
|
---|
386 |
|
---|
387 | return true;//sub_connections.reconnect();
|
---|
388 | }
|
---|
389 |
|
---|
390 | // ----------------------------------------------------------------
|
---|
391 |
|
---|
392 | function doDrsCalibration(where)
|
---|
393 | {
|
---|
394 | console.out(" Take DRS calibration ["+where+"]");
|
---|
395 |
|
---|
396 | service_feedback.voltageOff();
|
---|
397 |
|
---|
398 | var tm = new Date();
|
---|
399 |
|
---|
400 | while (1)
|
---|
401 | {
|
---|
402 | dim.send("FAD_CONTROL/START_DRS_CALIBRATION");
|
---|
403 | if (!takeRun("drs-pedestal", 1000)) // 40 / 20s (50Hz)
|
---|
404 | continue;
|
---|
405 |
|
---|
406 | // Does that fix the runopen before runclose problem?
|
---|
407 | //dim.wait("FAD_CONTROL", "Connected", 3000);
|
---|
408 | //v8.sleep(1000);
|
---|
409 |
|
---|
410 | if (!takeRun("drs-gain", 1000)) // 40 / 20s (50Hz)
|
---|
411 | continue;
|
---|
412 |
|
---|
413 | // Does that fix the runopen before runclose problem?
|
---|
414 | //dim.wait("FAD_CONTROL", "Connected", 3000);
|
---|
415 | //v8.sleep(1000);
|
---|
416 |
|
---|
417 | if (!takeRun("drs-pedestal", 1000)) // 40 / 20s (50Hz)
|
---|
418 | continue;
|
---|
419 |
|
---|
420 | dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
---|
421 | if (!takeRun("drs-pedestal", 1000)) // 40 / 20s (50Hz)
|
---|
422 | continue;
|
---|
423 | if (!takeRun("drs-time", 1000)) // 40 / 20s (50Hz)
|
---|
424 | continue;
|
---|
425 |
|
---|
426 | dim.send("FAD_CONTROL/RESET_SECONDARY_DRS_BASELINE");
|
---|
427 | if (!takeRun("pedestal", 1000)) // 40 / 10s (80Hz)
|
---|
428 | continue;
|
---|
429 |
|
---|
430 | dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
---|
431 | if (!takeRun("pedestal", 1000)) // 40 / 10s (80Hz)
|
---|
432 | continue;
|
---|
433 | // -----------
|
---|
434 | // 4'40 / 2'00
|
---|
435 |
|
---|
436 | break;
|
---|
437 | }
|
---|
438 |
|
---|
439 | console.out(" DRS calibration done [%.1f]".$((new Date()-tm)/1000));
|
---|
440 | }
|
---|
441 |
|
---|
442 | // ================================================================
|
---|
443 | // Code related to the lid
|
---|
444 | // ================================================================
|
---|
445 |
|
---|
446 | function OpenLid()
|
---|
447 | {
|
---|
448 | /*
|
---|
449 | while (Sun.horizon(-13).isUp)
|
---|
450 | {
|
---|
451 | var now = new Date();
|
---|
452 | var minutes_until_sunset = (Sun.horizon(-13).set - now)/60000;
|
---|
453 | console.out(now.toUTCString()+": Sun above FACT-horizon, lid cannot be opened: sleeping 1min, remaining %.1fmin".$(minutes_until_sunset));
|
---|
454 | v8.sleep(60000);
|
---|
455 | }*/
|
---|
456 |
|
---|
457 | var isClosed = dim.state("LID_CONTROL").name=="Closed";
|
---|
458 |
|
---|
459 | var tm = new Date();
|
---|
460 |
|
---|
461 | // Wait for lid to be open
|
---|
462 | if (isClosed)
|
---|
463 | {
|
---|
464 | console.out(" Open lid: start");
|
---|
465 | dim.send("LID_CONTROL/OPEN");
|
---|
466 | }
|
---|
467 | dim.wait("LID_CONTROL", "Open", 30000);
|
---|
468 |
|
---|
469 | if (isClosed)
|
---|
470 | console.out(" Open lid: done [%.1fs]".$((new Date()-tm)/1000));
|
---|
471 | }
|
---|
472 |
|
---|
473 | function CloseLid()
|
---|
474 | {
|
---|
475 | var isOpen = dim.state("LID_CONTROL").name=="Open";
|
---|
476 |
|
---|
477 | var tm = new Date();
|
---|
478 |
|
---|
479 | // Wait for lid to be open
|
---|
480 | if (isOpen)
|
---|
481 | {
|
---|
482 | console.out(" Close lid: start");
|
---|
483 | dim.send("LID_CONTROL/CLOSE");
|
---|
484 | }
|
---|
485 | dim.wait("LID_CONTROL", "Closed", 30000);
|
---|
486 |
|
---|
487 | if (isOpen)
|
---|
488 | console.out(" Close lid: end [%.1fs]".$((new Date()-tm)/1000));
|
---|
489 | }
|
---|
490 |
|
---|
491 | // ================================================================
|
---|
492 | // Code related to switching bias voltage on and off
|
---|
493 | // ================================================================
|
---|
494 |
|
---|
495 | var service_feedback = new Subscription("FEEDBACK/DEVIATION");
|
---|
496 |
|
---|
497 | service_feedback.onchange = function(evt)
|
---|
498 | {
|
---|
499 | if (this.cnt && evt.counter>this.cnt+12)
|
---|
500 | return;
|
---|
501 |
|
---|
502 | this.voltageStep = null;
|
---|
503 | if (!evt.data)
|
---|
504 | return;
|
---|
505 |
|
---|
506 | var delta = evt.obj['DeltaBias'];
|
---|
507 |
|
---|
508 | var avg = 0;
|
---|
509 | for (var i=0; i<320; i++)
|
---|
510 | avg += delta[i];
|
---|
511 | avg /= 320;
|
---|
512 |
|
---|
513 | if (this.previous)
|
---|
514 | this.voltageStep = Math.abs(avg-this.previous);
|
---|
515 |
|
---|
516 | this.previous = avg;
|
---|
517 |
|
---|
518 | console.out(" DeltaV="+this.voltageStep);
|
---|
519 | }
|
---|
520 |
|
---|
521 | // DN: Why is voltageOff() implemented as
|
---|
522 | // a method of a Subscription to a specific Service
|
---|
523 | // I naively would think of voltageOff() as an unbound function.
|
---|
524 | // I seems to me it has to be a method of a Subscription object, in order
|
---|
525 | // to use the update counting method. But does it have to be
|
---|
526 | // a Subscription to FEEDBACK/DEVIATION, or could it work with other services as well?
|
---|
527 | service_feedback.voltageOff = function()
|
---|
528 | {
|
---|
529 | var state = dim.state("BIAS_CONTROL").name;
|
---|
530 |
|
---|
531 | // check of feedback has to be switched on
|
---|
532 | var isOn = state=="VoltageOn" || state=="Ramping";
|
---|
533 | if (isOn)
|
---|
534 | {
|
---|
535 | console.out(" Voltage off: start");
|
---|
536 |
|
---|
537 | // Supress the possibility that the bias control is
|
---|
538 | // ramping and will reject the command to switch the
|
---|
539 | // voltage off
|
---|
540 | var isControl = dim.state("FEEDBACK").name=="CurrentControl";
|
---|
541 | if (isControl)
|
---|
542 | {
|
---|
543 | console.out(" Suspending feedback.");
|
---|
544 | dim.send("FEEDBACK/ENABLE_OUTPUT", false);
|
---|
545 | dim.wait("FEEDBACK", "CurrentCtrlIdle", 3000);
|
---|
546 | }
|
---|
547 |
|
---|
548 | // Switch voltage off
|
---|
549 | console.out(" Voltage on: switch off");
|
---|
550 | dim.send("BIAS_CONTROL/SET_ZERO_VOLTAGE");
|
---|
551 |
|
---|
552 | // If the feedback was enabled, re-enable it
|
---|
553 | if (isControl)
|
---|
554 | {
|
---|
555 | console.out(" Resuming feedback.");
|
---|
556 | dim.send("FEEDBACK/ENABLE_OUTPUT", true);
|
---|
557 | dim.wait("FEEDBACK", "CurrentControl", 3000);
|
---|
558 | }
|
---|
559 | }
|
---|
560 |
|
---|
561 | dim.wait("BIAS_CONTROL", "VoltageOff", 5000);
|
---|
562 |
|
---|
563 | // FEEDBACK stays in CurrentCtrl when Voltage is off but output enabled
|
---|
564 | // dim.wait("FEEDBACK", "CurrentCtrlIdle", 1000);
|
---|
565 |
|
---|
566 | if (isOn)
|
---|
567 | console.out(" Voltage off: end");
|
---|
568 | }
|
---|
569 |
|
---|
570 | // DN: The name of the method voltageOn() in the context of the method
|
---|
571 | // voltageOff() is a little bit misleading, since when voltageOff() returns
|
---|
572 | // the caller can be sure the voltage is off, but when voltageOn() return
|
---|
573 | // this is not the case, in the sense, that the caller can now take data.
|
---|
574 | // instead the caller of voltageOn() *must* call waitForVoltageOn() afterwards
|
---|
575 | // in order to safely take good-quality data.
|
---|
576 | // This could lead to nasty bugs in the sense, that the second call might
|
---|
577 | // be forgotten by somebody
|
---|
578 | //
|
---|
579 | // so I suggest to rename voltageOn() --> prepareVoltageOn()
|
---|
580 | // waitForVoltageOn() stays as it is
|
---|
581 | // and one creates a third method called:voltageOn() like this
|
---|
582 | /* service_feedback.voltageOn = function()
|
---|
583 | * {
|
---|
584 | * this.prepareVoltageOn();
|
---|
585 | * this.waitForVoltageOn();
|
---|
586 | * }
|
---|
587 | *
|
---|
588 | * */
|
---|
589 | // For convenience.
|
---|
590 |
|
---|
591 | service_feedback.voltageOn = function()
|
---|
592 | {
|
---|
593 | //if (Sun.horizon("FACT").isUp)
|
---|
594 | // throw new Error("Sun is above FACT-horizon, voltage cannot be switched on.");
|
---|
595 |
|
---|
596 | var isOff = dim.state("BIAS_CONTROL").name=="VoltageOff";
|
---|
597 | if (isOff)
|
---|
598 | {
|
---|
599 | console.out(" Voltage on: switch on");
|
---|
600 | //console.out(JSON.stringify(dim.state("BIAS_CONTROL")));
|
---|
601 |
|
---|
602 | dim.send("BIAS_CONTROL/SET_GLOBAL_DAC", 1);
|
---|
603 | }
|
---|
604 |
|
---|
605 | // Wait until voltage on
|
---|
606 | dim.wait("BIAS_CONTROL", "VoltageOn", 5000);
|
---|
607 |
|
---|
608 | // From now on the feedback waits for a valid report from the FSC
|
---|
609 | // and than switchs to CurrentControl
|
---|
610 | dim.wait("FEEDBACK", "CurrentControl", 60000);
|
---|
611 |
|
---|
612 | if (isOff)
|
---|
613 | {
|
---|
614 | console.out(" Voltage on: cnt="+this.cnt);
|
---|
615 |
|
---|
616 | this.previous = undefined;
|
---|
617 | this.cnt = this.get().counter;
|
---|
618 | this.voltageStep = undefined;
|
---|
619 | }
|
---|
620 | }
|
---|
621 |
|
---|
622 | service_feedback.waitForVoltageOn = function()
|
---|
623 | {
|
---|
624 | // waiting 45sec for the current control to stabilize...
|
---|
625 | // v8.sleep(45000);
|
---|
626 |
|
---|
627 | // ----- Wait for at least three updates -----
|
---|
628 | // The feedback is started as if the camera where at 0deg
|
---|
629 | // Then after the first temp update, the temperature will be set to the
|
---|
630 | // correct value (this has already happened)
|
---|
631 | // So we only have to wait for the current to get stable.
|
---|
632 | // This should happen after three to five current updates.
|
---|
633 | // So we want one recent temperature update
|
---|
634 | // and three recent current updates
|
---|
635 |
|
---|
636 | // Avoid output if condition is already fulfilled
|
---|
637 | if (this.cnt && this.get().counter>this.cnt+10)
|
---|
638 | return;
|
---|
639 |
|
---|
640 | // FIXME: timeout missing
|
---|
641 | console.out(" Feedback wait: start");
|
---|
642 |
|
---|
643 | function func(service)
|
---|
644 | {
|
---|
645 | if ((service.cnt!=undefined && service.get().counter>service.cnt+10) ||
|
---|
646 | (service.voltageStep && service.voltageStep<0.02))
|
---|
647 | return true;
|
---|
648 | }
|
---|
649 |
|
---|
650 | var now = new Date();
|
---|
651 | //v8.timeout(5*60000, func, this);
|
---|
652 | while ((this.cnt==undefined || this.get().counter<=this.cnt+10) && (!this.voltageStep || this.voltageStep>0.02))
|
---|
653 | v8.sleep();
|
---|
654 |
|
---|
655 | console.out(" Feedback wait: end [dV=%.3f, cnt=%d, %.2fs]".$(this.voltageStep, this.get().counter, (new Date()-now)/1000));
|
---|
656 | }
|
---|
657 |
|
---|
658 | // ================================================================
|
---|
659 | // Function to shutdown the system
|
---|
660 | // ================================================================
|
---|
661 |
|
---|
662 | function Shutdown()
|
---|
663 | {
|
---|
664 | console.out("Shutdown: start");
|
---|
665 |
|
---|
666 | service_feedback.voltageOff();
|
---|
667 | CloseLid();
|
---|
668 | dim.send("DRIVE_CONTROL/PARK");
|
---|
669 |
|
---|
670 | console.out("Waiting for telescope to park. This may take a while.");
|
---|
671 |
|
---|
672 | // FIXME: This might not work is the drive is already close to park position
|
---|
673 | dim.wait("DRIVE_CONTROL", "Locked", 3000);
|
---|
674 |
|
---|
675 | var sub = new Subscription("DRIVE_CONTROL/POINTING_POSITION");
|
---|
676 | sub.get(5000); // FIXME: Proper error message in case of failure
|
---|
677 |
|
---|
678 | function func()
|
---|
679 | {
|
---|
680 | var report = sub.get();
|
---|
681 |
|
---|
682 | var zd = report.obj['Zd'];
|
---|
683 | var az = report.obj['Az'];
|
---|
684 |
|
---|
685 | if (zd>100 && Math.abs(az)<1)
|
---|
686 | return true;
|
---|
687 |
|
---|
688 | return undefined;
|
---|
689 | }
|
---|
690 |
|
---|
691 | var now = new Date();
|
---|
692 | v8.timeout(150000, func);
|
---|
693 |
|
---|
694 | //dim.send("FEEDBACK/STOP");
|
---|
695 | dim.send("FEEDBACK/ENABLE_OUTPUT", false);
|
---|
696 | dim.send("FTM_CONTROL/STOP_TRIGGER");
|
---|
697 |
|
---|
698 | dim.wait("FEEDBACK", "CurrentCtrlIdle", 3000);
|
---|
699 | dim.wait("FTM_CONTROL", "Idle", 3000);
|
---|
700 |
|
---|
701 | var report = sub.get();
|
---|
702 |
|
---|
703 | console.out("");
|
---|
704 | console.out("Shutdown procedure seems to be finished...");
|
---|
705 | console.out(" Telescope at Zd=%.1fdeg Az=%.1fdeg".$(report.obj['Zd'], report.obj['Az']));
|
---|
706 | console.out(" Please make sure the park position was reached");
|
---|
707 | console.out(" and the telescope is not moving anymore.");
|
---|
708 | console.out(" Please check that the lid is closed and the voltage switched off.");
|
---|
709 | console.out("");
|
---|
710 | console.out("Shutdown: end ["+(new Date()-now)/1000+"s]");
|
---|
711 |
|
---|
712 | sub.close();
|
---|
713 | }
|
---|
714 |
|
---|
715 | // ================================================================
|
---|
716 | // Check datalogger subscriptions
|
---|
717 | // ================================================================
|
---|
718 |
|
---|
719 | var datalogger_subscriptions = new Subscription("DATA_LOGGER/SUBSCRIPTIONS");
|
---|
720 | datalogger_subscriptions.get(3000, false);
|
---|
721 |
|
---|
722 | datalogger_subscriptions.check = function()
|
---|
723 | {
|
---|
724 | var obj = this.get();
|
---|
725 | if (!obj.data)
|
---|
726 | throw new Error("DATA_LOGGER/SUBSCRIPTIONS not available.");
|
---|
727 |
|
---|
728 | var expected =
|
---|
729 | [
|
---|
730 | "BIAS_CONTROL/CURRENT",
|
---|
731 | "BIAS_CONTROL/DAC",
|
---|
732 | "BIAS_CONTROL/NOMINAL",
|
---|
733 | "BIAS_CONTROL/VOLTAGE",
|
---|
734 | "DRIVE_CONTROL/POINTING_POSITION",
|
---|
735 | "DRIVE_CONTROL/SOURCE_POSITION",
|
---|
736 | "DRIVE_CONTROL/STATUS",
|
---|
737 | "DRIVE_CONTROL/TRACKING_POSITION",
|
---|
738 | "FAD_CONTROL/CONNECTIONS",
|
---|
739 | "FAD_CONTROL/DAC",
|
---|
740 | "FAD_CONTROL/DNA",
|
---|
741 | "FAD_CONTROL/DRS_RUNS",
|
---|
742 | "FAD_CONTROL/EVENTS",
|
---|
743 | "FAD_CONTROL/FEEDBACK_DATA",
|
---|
744 | "FAD_CONTROL/FILE_FORMAT",
|
---|
745 | "FAD_CONTROL/FIRMWARE_VERSION",
|
---|
746 | "FAD_CONTROL/INCOMPLETE",
|
---|
747 | "FAD_CONTROL/PRESCALER",
|
---|
748 | "FAD_CONTROL/REFERENCE_CLOCK",
|
---|
749 | "FAD_CONTROL/REGION_OF_INTEREST",
|
---|
750 | "FAD_CONTROL/RUNS",
|
---|
751 | "FAD_CONTROL/RUN_NUMBER",
|
---|
752 | "FAD_CONTROL/START_RUN",
|
---|
753 | "FAD_CONTROL/STATISTICS1",
|
---|
754 | "FAD_CONTROL/STATISTICS2",
|
---|
755 | "FAD_CONTROL/STATS",
|
---|
756 | "FAD_CONTROL/STATUS",
|
---|
757 | "FAD_CONTROL/TEMPERATURE",
|
---|
758 | "FEEDBACK/CALIBRATED_CURRENTS",
|
---|
759 | "FEEDBACK/CALIBRATION",
|
---|
760 | "FEEDBACK/DEVIATION",
|
---|
761 | "FEEDBACK/REFERENCE",
|
---|
762 | "FSC_CONTROL/CURRENT",
|
---|
763 | "FSC_CONTROL/HUMIDITY",
|
---|
764 | "FSC_CONTROL/TEMPERATURE",
|
---|
765 | "FSC_CONTROL/VOLTAGE",
|
---|
766 | "FTM_CONTROL/COUNTER",
|
---|
767 | "FTM_CONTROL/DYNAMIC_DATA",
|
---|
768 | "FTM_CONTROL/ERROR",
|
---|
769 | "FTM_CONTROL/FTU_LIST",
|
---|
770 | "FTM_CONTROL/PASSPORT",
|
---|
771 | "FTM_CONTROL/STATIC_DATA",
|
---|
772 | "FTM_CONTROL/TRIGGER_RATES",
|
---|
773 | "LID_CONTROL/DATA",
|
---|
774 | "MAGIC_LIDAR/DATA",
|
---|
775 | "MAGIC_WEATHER/DATA",
|
---|
776 | "MCP/CONFIGURATION",
|
---|
777 | "PWR_CONTROL/DATA",
|
---|
778 | "RATE_CONTROL/THRESHOLD",
|
---|
779 | "RATE_SCAN/DATA",
|
---|
780 | "RATE_SCAN/PROCESS_DATA",
|
---|
781 | "TEMPERATURE/DATA",
|
---|
782 | "TIME_CHECK/OFFSET",
|
---|
783 | "TNG_WEATHER/DATA",
|
---|
784 | "TNG_WEATHER/DUST",
|
---|
785 | ];
|
---|
786 |
|
---|
787 | function map(entry)
|
---|
788 | {
|
---|
789 | if (entry.length==0)
|
---|
790 | return undefined;
|
---|
791 |
|
---|
792 | var rc = entry.split(',');
|
---|
793 | if (rc.length!=2)
|
---|
794 | throw new Error("Subscription list entry '"+entry+"' has wrong number of elements.");
|
---|
795 | return rc;
|
---|
796 | }
|
---|
797 |
|
---|
798 | var list = obj.data.split('\n').map(map);
|
---|
799 |
|
---|
800 | function check(name)
|
---|
801 | {
|
---|
802 | if (list.every(function(el){return el[0]!=name;}))
|
---|
803 | throw new Error("Subscription to '"+name+"' not available.");
|
---|
804 | }
|
---|
805 |
|
---|
806 | expected.forEach(check);
|
---|
807 | }
|
---|
808 |
|
---|
809 |
|
---|
810 |
|
---|
811 | // ================================================================
|
---|
812 | // Crosscheck all states
|
---|
813 | // ================================================================
|
---|
814 |
|
---|
815 | // ----------------------------------------------------------------
|
---|
816 | // Do a standard startup to bring the system in into a well
|
---|
817 | // defined state
|
---|
818 | // ----------------------------------------------------------------
|
---|
819 | include('scripts/Startup.js');
|
---|
820 |
|
---|
821 | // ----------------------------------------------------------------
|
---|
822 | // Check that everything we need is availabel to receive commands
|
---|
823 | // (FIXME: Should that go to the general CheckState?)
|
---|
824 | // ----------------------------------------------------------------
|
---|
825 | console.out("Checking send.");
|
---|
826 | checkSend(["MCP", "DRIVE_CONTROL", "LID_CONTROL", "FAD_CONTROL", "FEEDBACK"]);
|
---|
827 | console.out("Checking send: done");
|
---|
828 |
|
---|
829 | // ----------------------------------------------------------------
|
---|
830 | // Bring feedback into the correct operational state
|
---|
831 | // ----------------------------------------------------------------
|
---|
832 | console.out("Feedback init: start.");
|
---|
833 | service_feedback.get(5000);
|
---|
834 |
|
---|
835 | dim.send("FEEDBACK/ENABLE_OUTPUT", true);
|
---|
836 | dim.send("FEEDBACK/START_CURRENT_CONTROL", 0.);
|
---|
837 |
|
---|
838 | v8.timeout(3000, function() { var n = dim.state("FEEDBACK").name; if (n=="CurrentCtrlIdle" || n=="CurrentControl") return true; });
|
---|
839 |
|
---|
840 | // ----------------------------------------------------------------
|
---|
841 | // Connect to the DRS_RUNS service
|
---|
842 | // ----------------------------------------------------------------
|
---|
843 | console.out("Drs runs init: start.");
|
---|
844 |
|
---|
845 | var sub_drsruns = new Subscription("FAD_CONTROL/DRS_RUNS");
|
---|
846 | sub_drsruns.get(5000);
|
---|
847 | // FIXME: Check if the last DRS calibration was complete?
|
---|
848 |
|
---|
849 | function getTimeSinceLastDrsCalib()
|
---|
850 | {
|
---|
851 | // ----- Time since last DRS Calibration [min] ------
|
---|
852 | var runs = sub_drsruns.get(0);
|
---|
853 | var diff = (new Date()-runs.time)/60000;
|
---|
854 |
|
---|
855 | // Warning: 'roi=300' is a number which is not intrisically fixed
|
---|
856 | // but can change depending on the taste of the observers
|
---|
857 | var valid = runs.obj['run'][2]>0 && runs.obj['roi']==300;
|
---|
858 |
|
---|
859 | if (valid)
|
---|
860 | console.out(" Last DRS calib: %.1fmin ago".$(diff));
|
---|
861 | else
|
---|
862 | console.out(" No valid drs calibration available");
|
---|
863 |
|
---|
864 | return valid ? diff : null;
|
---|
865 | }
|
---|
866 |
|
---|
867 | // ----------------------------------------------------------------
|
---|
868 | // Make sure we will write files
|
---|
869 | // ----------------------------------------------------------------
|
---|
870 | dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
---|
871 |
|
---|
872 | // ----------------------------------------------------------------
|
---|
873 | // Print some information for the user about the
|
---|
874 | // expected first oberservation
|
---|
875 | // ----------------------------------------------------------------
|
---|
876 | var test = getObservation();
|
---|
877 | if (test!=undefined)
|
---|
878 | {
|
---|
879 | var n = new Date();
|
---|
880 | if (test==-1)
|
---|
881 | console.out(n.toUTCString()+": First observation scheduled for "+observations[0].start.toUTCString());
|
---|
882 | if (test>=0 && test<observations.length)
|
---|
883 | console.out(n.toUTCString()+": First observation should start immediately.");
|
---|
884 | if (observations[0].start>n+12*3600*1000)
|
---|
885 | console.out(n.toUTCString()+": No observations scheduled for the next 12 hours!");
|
---|
886 | }
|
---|
887 |
|
---|
888 | // ----------------------------------------------------------------
|
---|
889 | // Start main loop
|
---|
890 | // ----------------------------------------------------------------
|
---|
891 | console.out("Start main loop.");
|
---|
892 |
|
---|
893 | var run = -2; // getObservation never called
|
---|
894 | var sub;
|
---|
895 | var lastObs;
|
---|
896 | var sun = Sun.horizon(-13);
|
---|
897 | var system_on; // undefined
|
---|
898 |
|
---|
899 | while (1)
|
---|
900 | {
|
---|
901 | // Check if observation position is still valid
|
---|
902 | // If source position has changed, set run=0
|
---|
903 | var idxObs = getObservation();
|
---|
904 | if (idxObs===undefined)
|
---|
905 | break;
|
---|
906 |
|
---|
907 | // we are still waiting for the first observation in the schedule
|
---|
908 | if (idxObs==-1)
|
---|
909 | {
|
---|
910 | // flag that the first observation will be in the future
|
---|
911 | run = -1;
|
---|
912 | v8.sleep(1000);
|
---|
913 | continue;
|
---|
914 | }
|
---|
915 |
|
---|
916 | // Check if we have to take action do to sun-rise
|
---|
917 | var was_up = sun.isUp;
|
---|
918 | sun = Sun.horizon(-13);
|
---|
919 | if (!was_up && sun.isUp)
|
---|
920 | {
|
---|
921 | console.out("", "Sun rise detected.... automatic shutdown initiated!");
|
---|
922 | // FIXME: State check?
|
---|
923 | Shutdown();
|
---|
924 | system_on = false;
|
---|
925 | continue;
|
---|
926 | }
|
---|
927 |
|
---|
928 | // Current and next observation target
|
---|
929 | var obs = observations[idxObs];
|
---|
930 | var nextObs = observations[idxObs+1];
|
---|
931 |
|
---|
932 | // Check if observation target has changed
|
---|
933 | if (lastObs!=idxObs) // !Object.isEqual(obs, nextObs)
|
---|
934 | {
|
---|
935 | console.out("--- "+idxObs+" ---");
|
---|
936 | console.out("Current time: "+new Date().toUTCString());
|
---|
937 | console.out("Current observation: "+obs.start.toUTCString());
|
---|
938 | if (nextObs!=undefined)
|
---|
939 | console.out("Next observation: "+nextObs.start.toUTCString());
|
---|
940 | console.out("");
|
---|
941 |
|
---|
942 | // This is the first source, but we do not come from
|
---|
943 | // a scheduled 'START', so we have to check if the
|
---|
944 | // telescop is operational already
|
---|
945 | sub = 0;
|
---|
946 | if (run<0)
|
---|
947 | {
|
---|
948 | //Startup(); // -> Bias On/Off?, Lid open/closed?
|
---|
949 | //CloseLid();
|
---|
950 | }
|
---|
951 |
|
---|
952 | // The first observation had a start-time in the past...
|
---|
953 | // In this particular case start with the last entry
|
---|
954 | // in the list of measurements
|
---|
955 | if (run==-2)
|
---|
956 | sub = obs.length-1;
|
---|
957 |
|
---|
958 | run = 0;
|
---|
959 | }
|
---|
960 | lastObs = idxObs;
|
---|
961 |
|
---|
962 | if (nextObs==undefined && obs[obs.length-1].task!="SHUTDOWN")
|
---|
963 | throw Error("Last scheduled measurement must be a shutdown.");
|
---|
964 |
|
---|
965 | // We are done with all measurement slots for this
|
---|
966 | // observation... wait for next observation
|
---|
967 | if (sub>=obs.length)
|
---|
968 | {
|
---|
969 | v8.sleep(1000);
|
---|
970 | continue;
|
---|
971 | }
|
---|
972 |
|
---|
973 | var task = obs[sub].task;
|
---|
974 |
|
---|
975 | if (system_on===false && task!="STARTUP")
|
---|
976 | {
|
---|
977 | v8.sleep(1000);
|
---|
978 | continue;
|
---|
979 | }
|
---|
980 |
|
---|
981 | // Check if sun is still up... only DATA and RATESCAN must be suppressed
|
---|
982 | if ((task=="DATA" || task=="RATESCAN") && sun.isUp)
|
---|
983 | {
|
---|
984 | var now = new Date();
|
---|
985 | var remaining = (sun.set - now)/60000;
|
---|
986 | console.out(now.toUTCString()+" - "+obs[sub].task+": Sun above FACT-horizon: sleeping 1min, remaining %.1fmin".$(remaining));
|
---|
987 | v8.sleep(60000);
|
---|
988 | continue;
|
---|
989 | }
|
---|
990 |
|
---|
991 | console.out("\n"+(new Date()).toUTCString()+": Current measurement: "+obs[sub]);
|
---|
992 |
|
---|
993 | var power_states = sun.isUp || system_on===false ? [ "DriveOff" ] : [ "SystemOn" ];
|
---|
994 | var drive_states = sun.isUp || system_on===false ? undefined : [ "Armed", "Tracking", "OnTrack" ];
|
---|
995 |
|
---|
996 | // A scheduled task was found, lets check if all servers are
|
---|
997 | // still only and in reasonable states. If this is not the case,
|
---|
998 | // something unexpected must have happend and the script is aborted.
|
---|
999 | //console.out(" Checking states [general]");
|
---|
1000 | var table =
|
---|
1001 | [
|
---|
1002 | [ "TNG_WEATHER" ],
|
---|
1003 | [ "MAGIC_WEATHER" ],
|
---|
1004 | [ "CHAT" ],
|
---|
1005 | [ "SMART_FACT" ],
|
---|
1006 | [ "TEMPERATURE" ],
|
---|
1007 | [ "DATA_LOGGER", [ "NightlyFileOpen", "WaitForRun", "Logging" ] ],
|
---|
1008 | [ "FSC_CONTROL", [ "Connected" ] ],
|
---|
1009 | [ "MCP", [ "Idle" ] ],
|
---|
1010 | [ "TIME_CHECK", [ "Valid" ] ],
|
---|
1011 | [ "PWR_CONTROL", power_states/*[ "SystemOn" ]*/ ],
|
---|
1012 | // [ "AGILENT_CONTROL", [ "VoltageOn" ] ],
|
---|
1013 | [ "BIAS_CONTROL", [ "VoltageOff", "VoltageOn", "Ramping" ] ],
|
---|
1014 | [ "FEEDBACK", [ "CurrentControl", "CurrentCtrlIdle" ] ],
|
---|
1015 | [ "LID_CONTROL", [ "Open", "Closed" ] ],
|
---|
1016 | [ "DRIVE_CONTROL", drive_states/*[ "Armed", "Tracking", "OnTrack" ]*/ ],
|
---|
1017 | [ "FTM_CONTROL", [ "Idle", "TriggerOn" ] ],
|
---|
1018 | [ "FAD_CONTROL", [ "Connected", "WritingData" ] ],
|
---|
1019 | [ "RATE_SCAN", [ "Connected" ] ],
|
---|
1020 | [ "RATE_CONTROL", [ "Connected", "GlobalThresholdSet", "InProgress" ] ],
|
---|
1021 | ];
|
---|
1022 |
|
---|
1023 | if (!checkStates(table))
|
---|
1024 | {
|
---|
1025 | throw new Error("Something unexpected has happened. One of the servers"+
|
---|
1026 | "is in a state in which it should not be. Please,"+
|
---|
1027 | "try to find out what happened...");
|
---|
1028 | }
|
---|
1029 |
|
---|
1030 | datalogger_subscriptions.check();
|
---|
1031 |
|
---|
1032 | // Check if obs.task is one of the one-time-tasks
|
---|
1033 | switch (obs[sub].task)
|
---|
1034 | {
|
---|
1035 | case "STARTUP":
|
---|
1036 | console.out(" STARTUP", "");
|
---|
1037 | CloseLid();
|
---|
1038 |
|
---|
1039 | doDrsCalibration("startup"); // will switch the voltage off
|
---|
1040 |
|
---|
1041 | service_feedback.voltageOn();
|
---|
1042 | service_feedback.waitForVoltageOn();
|
---|
1043 |
|
---|
1044 | // Before we can switch to 3000 we have to make the right DRS calibration
|
---|
1045 | console.out(" Take single p.e. run.");
|
---|
1046 | while (!takeRun("pedestal", 5000));
|
---|
1047 |
|
---|
1048 | // It is unclear what comes next, so we better switch off the voltage
|
---|
1049 | service_feedback.voltageOff();
|
---|
1050 | system_on = true;
|
---|
1051 | break;
|
---|
1052 |
|
---|
1053 | case "SHUTDOWN":
|
---|
1054 | console.out(" SHUTDOWN", "");
|
---|
1055 | Shutdown();
|
---|
1056 | system_on = false;
|
---|
1057 |
|
---|
1058 | // FIXME: Avoid new observations after a shutdown until
|
---|
1059 | // the next startup (set run back to -2?)
|
---|
1060 | console.out(" Waiting for next startup.", "");
|
---|
1061 | sub++;
|
---|
1062 | continue;
|
---|
1063 |
|
---|
1064 | case "IDLE":
|
---|
1065 | v8.sleep(1000);
|
---|
1066 | continue;
|
---|
1067 |
|
---|
1068 | case "DRSCALIB":
|
---|
1069 | console.out(" DRSCALIB", "");
|
---|
1070 | doDrsCalibration("drscalib"); // will switch the voltage off
|
---|
1071 | break;
|
---|
1072 |
|
---|
1073 | case "SINGLEPE":
|
---|
1074 | console.out(" SINGLE-PE", "");
|
---|
1075 |
|
---|
1076 | // The lid must be closes
|
---|
1077 | CloseLid();
|
---|
1078 |
|
---|
1079 | // Check if DRS calibration is necessary
|
---|
1080 | var diff = getTimeSinceLastDrsCalib();
|
---|
1081 | if (diff>30 || diff==null)
|
---|
1082 | doDrsCalibration("singlepe"); // will turn voltage off
|
---|
1083 |
|
---|
1084 | // The voltage must be on
|
---|
1085 | service_feedback.voltageOn();
|
---|
1086 | service_feedback.waitForVoltageOn();
|
---|
1087 |
|
---|
1088 | // Before we can switch to 3000 we have to make the right DRS calibration
|
---|
1089 | console.out(" Take single p.e. run.");
|
---|
1090 | while (!takeRun("pedestal", 5000));
|
---|
1091 |
|
---|
1092 | // It is unclear what comes next, so we better switch off the voltage
|
---|
1093 | service_feedback.voltageOff();
|
---|
1094 | break;
|
---|
1095 |
|
---|
1096 | case "RATESCAN":
|
---|
1097 | console.out(" RATESCAN", "");
|
---|
1098 |
|
---|
1099 | var tm1 = new Date();
|
---|
1100 |
|
---|
1101 | // This is a workaround to make sure that we really catch
|
---|
1102 | // the new state and not the old one
|
---|
1103 | dim.send("DRIVE_CONTROL/STOP");
|
---|
1104 | dim.wait("DRIVE_CONTROL", "Armed", 5000);
|
---|
1105 |
|
---|
1106 | // The lid must be open
|
---|
1107 | OpenLid();
|
---|
1108 |
|
---|
1109 | // The voltage must be switched on
|
---|
1110 | service_feedback.voltageOn();
|
---|
1111 |
|
---|
1112 | if (obs.source != undefined)
|
---|
1113 | dim.send("DRIVE_CONTROL/TRACK_ON", obs[sub].source);
|
---|
1114 | else
|
---|
1115 | dim.send("DRIVE_CONTROL/TRACK", obs[sub].ra, obs[sub].dec);
|
---|
1116 |
|
---|
1117 | dim.wait("DRIVE_CONTROL", "OnTrack", 150000); // 110s for turning and 30s for stabilizing
|
---|
1118 |
|
---|
1119 | service_feedback.waitForVoltageOn();
|
---|
1120 |
|
---|
1121 | var tm2 = new Date();
|
---|
1122 |
|
---|
1123 | // Start rate scan
|
---|
1124 | dim.send("RATE_SCAN/START_THRESHOLD_SCAN", 50, 1000, -10);
|
---|
1125 |
|
---|
1126 | // Lets wait if the ratescan really starts... this might take a few
|
---|
1127 | // seconds because RATE_SCAN configures the ftm and is waiting for
|
---|
1128 | // it to be configured.
|
---|
1129 | dim.wait("RATE_SCAN", "InProgress", 10000);
|
---|
1130 | dim.wait("RATE_SCAN", "Connected", 2700000);
|
---|
1131 |
|
---|
1132 | // this line is actually some kind of hack.
|
---|
1133 | // after the Ratescan, no data is written to disk. I don't know why, but it happens all the time
|
---|
1134 | // So I decided to put this line here as a kind of patchwork....
|
---|
1135 | //dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
---|
1136 |
|
---|
1137 | console.out(" Ratescan done [%.1fs, %.1fs]".$((tm2-tm1)/1000, (new Date()-tm2)/1000));
|
---|
1138 | break; // case "RATESCAN"
|
---|
1139 |
|
---|
1140 | case "DATA":
|
---|
1141 |
|
---|
1142 | // ========================== case "DATA" ============================
|
---|
1143 | /*
|
---|
1144 | if (Sun.horizon("FACT").isUp)
|
---|
1145 | {
|
---|
1146 | console.out(" SHUTDOWN","");
|
---|
1147 | Shutdown();
|
---|
1148 | console.out(" Exit forced due to broken schedule", "");
|
---|
1149 | exit();
|
---|
1150 | }
|
---|
1151 | */
|
---|
1152 | // Calculate remaining time for this observation in minutes
|
---|
1153 | var remaining = nextObs==undefined ? 0 : (nextObs.start-new Date())/60000;
|
---|
1154 |
|
---|
1155 | // ------------------------------------------------------------
|
---|
1156 |
|
---|
1157 | console.out(" Run #"+run+" (remaining "+parseInt(remaining)+"min)");
|
---|
1158 |
|
---|
1159 | // ----- Time since last DRS Calibration [min] ------
|
---|
1160 | var diff = getTimeSinceLastDrsCalib();
|
---|
1161 |
|
---|
1162 | // Changine pointing position and take calibration...
|
---|
1163 | // ...every four runs (every ~20min)
|
---|
1164 | // ...if at least ten minutes of observation time are left
|
---|
1165 | // ...if this is the first run on the source
|
---|
1166 | var point = (run%4==0 && remaining>10) || run==0;
|
---|
1167 |
|
---|
1168 | // Take DRS Calib...
|
---|
1169 | // ...every four runs (every ~20min)
|
---|
1170 | // ...at last every two hours
|
---|
1171 | // ...when DRS temperature has changed by more than 2deg (?)
|
---|
1172 | // ...when more than 15min of observation are left
|
---|
1173 | // ...no drs calibration was done yet
|
---|
1174 | var drscal = (run%4==0 && (remaining>15 && diff>70)) || diff==null;
|
---|
1175 |
|
---|
1176 | if (point)
|
---|
1177 | {
|
---|
1178 | // Change wobble position every four runs,
|
---|
1179 | // start with alternating wobble positions each day
|
---|
1180 | var wobble = (parseInt(run/4) + parseInt(new Date()/1000/3600/24-0.5))%2+1;
|
---|
1181 |
|
---|
1182 | //console.out(" Move telescope to '"+source+"' "+offset+" "+wobble);
|
---|
1183 | console.out(" Move telescope to '"+obs[sub].source+"' ["+wobble+"]");
|
---|
1184 |
|
---|
1185 | //var offset = observations[obs][2];
|
---|
1186 | //var wobble = observations[obs][3 + parseInt(run/4)%2];
|
---|
1187 |
|
---|
1188 | //dim.send("DRIVE_CONTROL/TRACK_SOURCE", offset, wobble, source);
|
---|
1189 |
|
---|
1190 | dim.send("DRIVE_CONTROL/TRACK_WOBBLE", wobble, obs[sub].source);
|
---|
1191 |
|
---|
1192 | // Do we have to check if the telescope is really moving?
|
---|
1193 | // We can cross-check the SOURCE service later
|
---|
1194 | }
|
---|
1195 |
|
---|
1196 | if (drscal)
|
---|
1197 | doDrsCalibration("data"); // will turn voltage off
|
---|
1198 |
|
---|
1199 | OpenLid();
|
---|
1200 |
|
---|
1201 | // voltage must be switched on after the lid is open for the
|
---|
1202 | // feedback to adapt the voltage properly to the night-sky
|
---|
1203 | // background light level.
|
---|
1204 | service_feedback.voltageOn();
|
---|
1205 |
|
---|
1206 | // This is now th right time to wait for th drive to be stable
|
---|
1207 | dim.wait("DRIVE_CONTROL", "OnTrack", 150000); // 110s for turning and 30s for stabilizing
|
---|
1208 |
|
---|
1209 | // Now we have to be prepared for data-taking:
|
---|
1210 | // make sure voltage is on
|
---|
1211 | service_feedback.waitForVoltageOn();
|
---|
1212 |
|
---|
1213 | // If pointing had changed, do calibration
|
---|
1214 | if (point)
|
---|
1215 | {
|
---|
1216 | console.out(" Calibration.");
|
---|
1217 |
|
---|
1218 | // Calibration (2% of 20')
|
---|
1219 | while (1)
|
---|
1220 | {
|
---|
1221 | if (!takeRun("pedestal", 1000)) // 80 Hz -> 10s
|
---|
1222 | continue;
|
---|
1223 | if (!takeRun("light-pulser-ext", 1000)) // 80 Hz -> 10s
|
---|
1224 | continue;
|
---|
1225 | break;
|
---|
1226 | }
|
---|
1227 | }
|
---|
1228 |
|
---|
1229 | console.out(" Taking data: start [5min]");
|
---|
1230 |
|
---|
1231 | var len = 300;
|
---|
1232 | while (len>0)
|
---|
1233 | {
|
---|
1234 | var time = new Date();
|
---|
1235 | if (takeRun("data", -1, len)) // Take data (5min)
|
---|
1236 | break;
|
---|
1237 |
|
---|
1238 | len -= parseInt((new Date()-time)/1000);
|
---|
1239 | }
|
---|
1240 |
|
---|
1241 | console.out(" Taking data: done");
|
---|
1242 | run++;
|
---|
1243 |
|
---|
1244 | continue; // case "DATA"
|
---|
1245 | }
|
---|
1246 |
|
---|
1247 | if (nextObs!=undefined && sub==obs.length-1)
|
---|
1248 | console.out(" Waiting for next observation scheduled for "+nextObs.start.toUTCString(),"");
|
---|
1249 |
|
---|
1250 | sub++;
|
---|
1251 | }
|
---|
1252 |
|
---|
1253 | sub_drsruns.close();
|
---|
1254 |
|
---|
1255 | // ================================================================
|
---|
1256 | // Comments and ToDo goes here
|
---|
1257 | // ================================================================
|
---|
1258 |
|
---|
1259 | // error handline : http://www.sitepoint.com/exceptional-exception-handling-in-javascript/
|
---|
1260 | // classes: http://www.phpied.com/3-ways-to-define-a-javascript-class/
|
---|
1261 | //
|
---|
1262 | // Arguments: TakeFirstDrsCalib
|
---|
1263 | // To be determined: How to stop the script without foreceful interruption?
|
---|