# Configuration data for the Evidence Control System # # The first entry of each line gives the requester for the parameter in # the second entry. The remaining text of the line is send in reponse # to the configuration request. # A plus sign before the line break signals continuation of the line. # # Sky Quality Monitor # SQM address sqm.ethz.ch SQM port 10001 SQM period 20 # # Central Data Collector # # Minumum absolute change to include in history buffer. Standard regular # expressions are supported. Negative value means do not to disk. DColl minchange SQM/NSB:0.2 Alarm/MasterAlarm:-1 Alarm/Summary:-1 + BIAS/VOLT/ID00/*-*:0.01 BIAS/Textout:-1 + ARDUINO/VAL*:0.2 ARDUINO/VAL0[79]:0.5 DColl datadir ../../../no_back/EvidenceData DColl logfile ../../../no_back/EvidenceData/Evidence.log DColl sizeupdate 30 # Min delay in seconds between file size updates DColl histsize 5000 # Number of items in history buffer # # Alarm Handler # Alarm servers DIS_DNS DColl SQM Config BIAS ARDUINO # Servers to watch Alarm period 30 # Check interval in seconds # # Bias control # Bias PixMapTable ../config/PixelMap.txt Bias TimeOut 0.50 # Timeout to return from read (0.01,...5.00) s Bias StatusRefreshRate 2.00 # Status update rate (0.01,...50.00) Hz Bias CCPort 3000 # Socket port Bias DACMin 11008 # Starting point of DAC to voltage calibration Bias DACMax 12496 # End point Bias HVCalibOffset 67.000000 # Calibration of DAC to voltage values Bias HVCalibSlope 0.006400 # Calibration of DAC to voltage values Bias HVMaxDiff 500 # Maximum change of DAC value per iteration Bias Boards FTCVIP44 # List of HV boards