1 | ----------------------------------------------------------------------------------
|
---|
2 | -- Company: TU Dortmund, Lehrstuhl fuer experimentelle Physik 5b, Astroteilchenphysik
|
---|
3 | -- Engineer: D.Neise
|
---|
4 | --
|
---|
5 | -- Create Date: April 2011
|
---|
6 | -- Design Name:
|
---|
7 | -- Module Name: fad_rs485_definitions
|
---|
8 | -- Project Name:
|
---|
9 | -- Target Devices:
|
---|
10 | -- Tool versions:
|
---|
11 | -- Description: library file for FAD design
|
---|
12 | --
|
---|
13 | -- Dependencies:
|
---|
14 | --
|
---|
15 | -- Revision:
|
---|
16 | -- Revision 0.01 - File Created
|
---|
17 | --
|
---|
18 | -- Additional Comments:
|
---|
19 | -- Many thanks to Q. Weitzel
|
---|
20 | ----------------------------------------------------------------------------------
|
---|
21 |
|
---|
22 |
|
---|
23 | library IEEE;
|
---|
24 | use IEEE.STD_LOGIC_1164.all;
|
---|
25 | use IEEE.STD_LOGIC_ARITH.ALL;
|
---|
26 | -- use IEEE.STD_LOGIC_UNSIGNED.ALL;
|
---|
27 | -- use IEEE.NUMERIC_STD.ALL;
|
---|
28 |
|
---|
29 | package fad_rs485_constants is
|
---|
30 |
|
---|
31 | constant FAD_RS485_INPUT_CLK_F : integer := 50000000; -- 50MHz
|
---|
32 | --communication with FTM
|
---|
33 | constant RS485_BAUD_RATE : integer := 250000; -- bits / sec in our case
|
---|
34 | constant RS485_MESSAGE_LEN_BYTES : integer := 7; -- @250kbaud --> 308us in total or (@50Mhz) 15400 clk cycles.
|
---|
35 | -- notes about the timeout:
|
---|
36 | -- the timeout is measured *after* the receiption of the 1st byte ... not after the 1st startbit.
|
---|
37 | -- one byte consists of 1 startbit, 8 databits, 2 stopbit2 --> 11 bits in total.
|
---|
38 | -- in order to have some ~10% contingency, we decided to put 13 bits instead of 11
|
---|
39 | --
|
---|
40 | -- so this timeout evaluates to 18200 clk cycles or 364us *after* the 1st byte was received.
|
---|
41 | -- this means, one message is trunkated only, if it is longer than ~356us in total.
|
---|
42 | -- this might be subject to changes.
|
---|
43 | -- keep in mind that, there is an additional timeout
|
---|
44 | constant RS485_TIMEOUT : integer := (RS485_MESSAGE_LEN_BYTES * 13) * (FAD_RS485_INPUT_CLK_F / RS485_BAUD_RATE);
|
---|
45 |
|
---|
46 | end fad_rs485_constants;
|
---|