1 | \documentclass[a4paper]{article}
|
---|
2 |
|
---|
3 | %\setlength{\topmargin}{0mm} %1 inch is always there!
|
---|
4 | %\setlength{\oddsidemargin}{0mm} %1 inch is always there!
|
---|
5 | %\setlength{\evensidemargin}{0mm} %1 inch is always there!
|
---|
6 |
|
---|
7 | %\setlength{\textwidth}{16cm}
|
---|
8 |
|
---|
9 | % keine Kopfzeile?
|
---|
10 | %\setlength{\headheight}{0mm}
|
---|
11 | %\setlength{\headsep}{0mm}
|
---|
12 |
|
---|
13 |
|
---|
14 | %um die deutschen Umlaute eingeben zu können
|
---|
15 | % müssen diese 3 Pakete eingebunden werden.
|
---|
16 | % welches der Pakete was macht, weiss ich nicht.
|
---|
17 | \usepackage[T1]{fontenc}
|
---|
18 | \usepackage[latin1]{inputenc}
|
---|
19 | %\usepackage{ngerman} % nur wenn z.B. 'Inhaltsverzeichnis' auch deutsch sein soll.
|
---|
20 |
|
---|
21 | \usepackage{graphicx} % for pictures
|
---|
22 | \usepackage{float} % for figures with english descriptions
|
---|
23 |
|
---|
24 | \restylefloat{figure} % can nor force it with H
|
---|
25 | \restylefloat{table} % can nor force it with H
|
---|
26 |
|
---|
27 | \title{FSC - facts about the board}
|
---|
28 | \author{D. Neise}
|
---|
29 | \date{07.02.2011}
|
---|
30 |
|
---|
31 | \begin{document}
|
---|
32 |
|
---|
33 | %title page contains TOC
|
---|
34 | \maketitle
|
---|
35 | \tableofcontents
|
---|
36 | \newpage
|
---|
37 |
|
---|
38 | %\listoffigures
|
---|
39 | %\listoftables
|
---|
40 |
|
---|
41 | \section{Basic Facts and Purpose}
|
---|
42 | % no pictures in SVN repos ... no space.
|
---|
43 | %\emph{picture here - 3D model of FSC}
|
---|
44 |
|
---|
45 | This document presents electronic facts and figures of FACTs FSC board, which stands for {\bf F}act {\bf S}low {\bf C}ontrol. The name is a bit misleading, since the boards sole purpose is to monitor slowly changing parameters, such as:
|
---|
46 | \begin{itemize}
|
---|
47 | \item up to 64 temperatures (RTD like sensors, e.g. Pt1000 or Pt100),
|
---|
48 | \item up to 4 humidities (designed for Honeywell HIH-40xx family),
|
---|
49 | \item the DC levels of all FACT low voltage supply channels(32 ??? channels),
|
---|
50 | \item the current drawn from each of these channels (converted to a voltage inside LV-supply).
|
---|
51 | \end{itemize}
|
---|
52 |
|
---|
53 | FSC therefor brings an 8MHz ATmega32L micro controller(MCU), used to readout the muxed 24bit sigma delta ADC (AD7719) which is connected to the RTDs. In addition the ATmegas internal 10bit ADC is used to monitor the humidity, LV-voltages and LV-currents. The muxers on FSC belong to analog devices ADG77xx family, and are controlled by the MCU according to the users needs. The User has access to FSC via Ethernet Interface, comprised(?) by wiznets W5100, the younger brother of W5300, which is used on FACTs FAD boards. AD7719 and W5100 communicate with the MCU via an SPI bus, which results in the fact, that User interaction might slow down temperature measurement or vice versa. Additionally the user should be aware, that sigma delta ADCs have a long settling, when muxed. Redout of all 64 temperature channels takes about 13s, while the one channel might be readout with >10Hz. In addition FSC runs a 32bit timer, counting seconds since timer init. The timer is initialized to zero, when FSC is powered. User may synchronize FSCs timer to Unix time. \newline
|
---|
54 | We do not talk here about the accelerometer on the FSC, since this piece it not part of the original proposal.
|
---|
55 |
|
---|
56 | \subsection{measurement modes}
|
---|
57 | FSC knows two measurement modes. The first is \emph{on demand}. When FSC measures on demand, user may send a command telling FSC, what to measure. FSC will measure it and return the result, only after the measurement was finished. It is possible to tell FSC to measure several sensors at a time.
|
---|
58 | If the user asked for a temperature measurement and FSC had to change the muxer setting, this might take up to 300ms.
|
---|
59 | During a measurement on demand, FSC is not checking for incoming commands. So new commands will pile up in W5100 input FIFO. So sending a lot of on demand commands can easily delay FSC reaction a lot.
|
---|
60 |
|
---|
61 | The second mode is \emph{free running}. In free running mode FSC measures all activated sensors and stores the value and time tuples. Once all sensors were measured, FSC returns a measurement telegram. The user can define which sensors should be measured and which should be left out. Additionally one can tell FSC how often it should start a measurement cycle.
|
---|
62 | \section{Ethernet Interface}
|
---|
63 | FSC runs as a TCP/IP server, this means after W5100 was initialized, FSC will listen on one Port, but will not attempt to connect to any other server. Since W5100 does not support DHCP, FSC has a fix IP\footnote{see FACT Elogbook / doc}. The Port is not yet defined, but since FADs use Ports 5000-5007, there is a high probability, that you can access FSC via Port 5000 as well.
|
---|
64 | For simplicity of firmware coding, the UI is non human readable, commands from User to FCS may look like this.
|
---|
65 | \begin{table}[htpb]
|
---|
66 | \begin{tabular}{|l|l|l|}
|
---|
67 | \hline
|
---|
68 | address & mnemonic & description \\
|
---|
69 | \hline
|
---|
70 | byte 0 & command & see reference to next subsection\\
|
---|
71 | byte 1 & ticket no & number of commands - upcounting \\
|
---|
72 | byte 2 & length & length of data section - if apropriate\\
|
---|
73 | byte 3..1k & data & parameters for command - if apropriate\\
|
---|
74 | \hline
|
---|
75 | \end{tabular}
|
---|
76 | \caption{composition of FSC commands}
|
---|
77 | \label{tbl_UserCommand}
|
---|
78 | \end{table}
|
---|
79 |
|
---|
80 | FSCs answers might be eigther a short acknowledgement, in case the user changed a just setting, or a measurement telegram.
|
---|
81 | An acknowledgement contains the number of the command, which caused the FSC to answer and looks like this.
|
---|
82 | \begin{table}[htpb]
|
---|
83 | \begin{tabular}{|l|l|l|}
|
---|
84 | \hline
|
---|
85 | address & mnemonic & description \\
|
---|
86 | \hline
|
---|
87 | byte 0 & ticket no & number of the command, \\
|
---|
88 | &&causing this answer: range: 0x01 .. 0xFF \\
|
---|
89 | byte 1 & length & length of data section \\
|
---|
90 | byte 2 & command & first byte in data section: repeated command \\
|
---|
91 | byte 3..1k & data & parameters for command - repetition as well\\
|
---|
92 | \hline
|
---|
93 | \end{tabular}
|
---|
94 | \caption{composition of FSCs answer - acknowledgement}
|
---|
95 | \label{tbl_FSC_ACK}
|
---|
96 | \end{table}
|
---|
97 |
|
---|
98 | If the user asked for a measurement on demand, the acknowledgement contains the measurement telegram inside the data section.
|
---|
99 | For a detailed description of the telegram refer to \emph{the right subsection}.
|
---|
100 | In case the FSC returns data measured, because it was switched to free running mode, the message looks slightly different.
|
---|
101 |
|
---|
102 | \begin{table}[htpb]
|
---|
103 | \begin{tabular}{|l|l|l|}
|
---|
104 | \hline
|
---|
105 | address & mnemonic & description \\
|
---|
106 | \hline
|
---|
107 | byte 0 & free run code & 0x00 - is defined not to \\
|
---|
108 | &&be a legal ticket number \\
|
---|
109 | byte 1 & length & length of data section \\
|
---|
110 | byte 2..1k & telegram & see \emph{the right subsection}\\
|
---|
111 | \hline
|
---|
112 | \end{tabular}
|
---|
113 | \caption{composition of FSCs free running massage}
|
---|
114 | \label{tbl_FSC_MESS}
|
---|
115 | \end{table}
|
---|
116 |
|
---|
117 | \newpage
|
---|
118 | \subsection{FSC registers}
|
---|
119 |
|
---|
120 | FSC uses the following registers.
|
---|
121 | \begin{table}[htpb]
|
---|
122 | \begin{tabular}{|l|l|l|}
|
---|
123 | \hline
|
---|
124 | {\bf address} & {\bf name} & {\bf description } \\
|
---|
125 | \hline
|
---|
126 | 0x00 & status & stats register - TBR (e.g. mode; timer synched?; ) \\
|
---|
127 | 0x01 & error & error register - \\
|
---|
128 | && TBR (AD7719 found disconnected sensor, \\
|
---|
129 | &&HUM or TEMP too high, V or I out of range)\\
|
---|
130 | 0x02 & timer3 & \\
|
---|
131 | 0x03 & timer2 & \\
|
---|
132 | 0x04 & timer1 & \\
|
---|
133 | 0x05 & timer0 & current time\\
|
---|
134 | 0x06 & TempEn7 & \\
|
---|
135 | 0x07 & TempEn6 & \\
|
---|
136 | 0x08 & TempEn5 & \\
|
---|
137 | 0x09 & TempEn4 & \\
|
---|
138 | 0x0A & TempEn3 & \\
|
---|
139 | 0x0B & TempEn2 & \\
|
---|
140 | 0x0C & TempEn1 & \\
|
---|
141 | 0x0D & TempEn0 & \\
|
---|
142 | 0x0E & HumiEn0 & \\
|
---|
143 | 0x0F & AcceEn0 & \\
|
---|
144 | 0x10 & VoltEn4 & \\
|
---|
145 | 0x11 & VoltEn3 & \\
|
---|
146 | 0x12 & VoltEn2 & \\
|
---|
147 | 0x13 & VoltEn1 & \\
|
---|
148 | 0x14 & VoltEn0 & \\
|
---|
149 | 0x15 & CurrEn4 & \\
|
---|
150 | 0x16 & CurrEn3 & \\
|
---|
151 | 0x17 & CurrEn2 & \\
|
---|
152 | 0x18 & CurrEn1 & \\
|
---|
153 | 0x19 & CurrEn0 & \\
|
---|
154 | ... & ... & to be completed \\
|
---|
155 | \hline
|
---|
156 | \end{tabular}
|
---|
157 | \caption{FSC registers}
|
---|
158 | \label{tbl_REG_overview}
|
---|
159 | \end{table}
|
---|
160 |
|
---|
161 |
|
---|
162 | \subsection{getting out results - the telegram}
|
---|
163 | Most probably not every input channel will be connected to a sensor. In order not to measure unconnected channels, the user may define, which sensor is active.
|
---|
164 |
|
---|
165 |
|
---|