1 | -*-*- END -*-*-
|
---|
2 |
|
---|
3 | *** Version 0.10 (2006/10/10)
|
---|
4 |
|
---|
5 | - general: all executables now check consistency of the root version
|
---|
6 | installed with the root version used for compilation. The return
|
---|
7 | code in this ace is 255.
|
---|
8 |
|
---|
9 | - general: The algorithm to build seqeunces has been redesigned
|
---|
10 | completly. It is now more flexible in terms of a resource file
|
---|
11 | resources/sequences.rc which can be used to partly overwrite
|
---|
12 | the default algorithm and defined the important part of the
|
---|
13 | algorithm. It also takes correctly into account several ways
|
---|
14 | of taking wobble-data. Currently the new algorithm doesn't take
|
---|
15 | the number of pedestal events anymore into account (so a sequence
|
---|
16 | could have much less than 1000 pedestal events and data runs are
|
---|
17 | no-more used instead)
|
---|
18 |
|
---|
19 | - general: a lot of small changes to make the code compatible with
|
---|
20 | root 5.12/00 and gcc 4.1
|
---|
21 |
|
---|
22 | - general: Fixed some warnings thrown if more warnings are switched
|
---|
23 | on in the compiler
|
---|
24 |
|
---|
25 | - general: Added a function to MMath which returns the Median of
|
---|
26 | the distribution abs(y[i]-median) but at 68:32 division instead
|
---|
27 | of 50:50, which is somehow the mediani counterpart of the rms.
|
---|
28 |
|
---|
29 | - general: MAstroCatalog allows now to read calatog files (as bsc5)
|
---|
30 | even if they are compressed with gzip (recommended compression
|
---|
31 | is with "-1")
|
---|
32 |
|
---|
33 | - showplot:
|
---|
34 | + batch mode creation of image files now works with root 5.12/00
|
---|
35 | + added support for writing bmp (though it never produces
|
---|
36 | bmp which can be read by programs like xv or gimp)
|
---|
37 | + added support for xml
|
---|
38 | + added new option to start the display with a different size, by
|
---|
39 | --display-width=nnn or --display-height=nnn
|
---|
40 | + added options to define the canvas size when the display is started
|
---|
41 | --canvas-width=nnn or --canvas-height=nnn
|
---|
42 | the option can also be used for batch-mode conversion
|
---|
43 | + added an option which automatically fits the display size to the
|
---|
44 | desktop-size: --auto-size
|
---|
45 |
|
---|
46 | - merpp: didn't recognize files with the extension .raw.gz - fixed.
|
---|
47 |
|
---|
48 | - merpp: allow the reports to have 1000ms due to a bug in the camera
|
---|
49 | program.
|
---|
50 |
|
---|
51 | - callisto: New swapped pixels have been found and corrected. For
|
---|
52 | details see MRawRunHeader::FixAssignment()
|
---|
53 |
|
---|
54 | - callisto: Callisto now raises an error if one of the input files could
|
---|
55 | not be opened.
|
---|
56 |
|
---|
57 | - callisto: In some rare cases it could happen that in the hi-gain
|
---|
58 | extraction of the digital filter the extractor returned nonsense
|
---|
59 | results due a wrong initializion of a variable
|
---|
60 |
|
---|
61 | - callisto: The lo-gains have been marked as valid in some cases
|
---|
62 | when they got not extracted at all (deltsumlo=deltatimelo=0) because
|
---|
63 | the allowed extraction range (fLoGainLast-fLoGainFirst) was
|
---|
64 | smaller than the number of slices (fLoGainWindowSize) needed
|
---|
65 | by the lo-gain extractor
|
---|
66 |
|
---|
67 | - callisto: Updated absolute calibration constants (muon calibration)
|
---|
68 |
|
---|
69 | - callisto: fixed a bug which caused the hi-gain saturation not
|
---|
70 | to be handled properly
|
---|
71 |
|
---|
72 | - callisto: fixed a bug which gave weird results if hi- _and_
|
---|
73 | lo-gain could not be extracted properly
|
---|
74 |
|
---|
75 | - callisto: improves handling of extracted signal if lo- and/or
|
---|
76 | hi-gain could not be extracted properly. If no appropriate
|
---|
77 | calibration of either the signal or the arrival time is possible
|
---|
78 | the pixel is now markes as unsuitable instead of estimated.
|
---|
79 |
|
---|
80 | - callisto: Fixed a problem in the spline extraction which gave
|
---|
81 | weird results if the signal was extracted from the first (and
|
---|
82 | highest) slice
|
---|
83 |
|
---|
84 | - callisto: Fixed a bug regarding the use of the QE which doesn't
|
---|
85 | effect the result because the default is used anyhow.
|
---|
86 | (The bug was there since 14/07/2005)
|
---|
87 |
|
---|
88 | - callisto: Changed the default for fgLoGainStartShift
|
---|
89 |
|
---|
90 | - callisto: Fixed a bug which caused all hi-/lo-gain calibration
|
---|
91 | factors to be always 10 for all pixels as soon as the first
|
---|
92 | calibration update has happend.
|
---|
93 |
|
---|
94 | - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
|
---|
95 | was off by more than one slice (which gives wrong values for
|
---|
96 | pixels which have saturated the hi-gain) This was a problem
|
---|
97 | mainly for timing studies, not so much for the automatic standard
|
---|
98 | analysis. Also the values for the Spline have been changed slightly:
|
---|
99 | + Digital Filter from 1.70 to 0.95
|
---|
100 | + Spline from 1.39 to 1.30
|
---|
101 | The numbers were sorted out by an extensive test in the
|
---|
102 | test-database.
|
---|
103 |
|
---|
104 | - callisto: Removed the tab showing the average calibrated arrival
|
---|
105 | time. It never gave useful information.
|
---|
106 |
|
---|
107 | - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
|
---|
108 | lo-gain pulse for data pulses if hi- and lo-gain have saturated
|
---|
109 | and both were extracted because the hi-gain was above the
|
---|
110 | LoGainSwitch.
|
---|
111 |
|
---|
112 | - callisto: Now tab "HiLoOff" which shows the offset between hi- and
|
---|
113 | lo-gain pulse position (after application of LoGainOffset, which
|
---|
114 | means in the ideal case it is 0) for data pulses if hi- and lo-gain
|
---|
115 | have saturated and both were extracted because the hi-gain was above
|
---|
116 | the LoGainSwitch.
|
---|
117 |
|
---|
118 | - callisto: After extensive tests a new threshold level for determination
|
---|
119 | of the pulse position has been found at 50phe. This is due to the
|
---|
120 | fact that for lower pulses the arrival time changes its average
|
---|
121 | behaviour dramatically. It tends to the average of the extraction
|
---|
122 | range and starts sticking to non-floating point numbers (5, 6, 7, ...)
|
---|
123 |
|
---|
124 | - callisto: Added two more plots to the calibration part. The average
|
---|
125 | extracted signal and the average extracted arrival time as
|
---|
126 | extracted by the signal extractor (This can help debugging problems
|
---|
127 | because it doesn't involve a fit)
|
---|
128 |
|
---|
129 | - star: changed the fit for the effective on time such that initial
|
---|
130 | values are calculated automatically now instead of using build
|
---|
131 | in values. This makes the fit more indepedant of the underlaying
|
---|
132 | rates. With a test of ~350 sequences in the test database it could
|
---|
133 | be shown that the new fit gives the same result +/-1sek.
|
---|
134 | The highest deviation was +5s the lowest -10s. You can now control
|
---|
135 | the bahaviour with two resource values:
|
---|
136 | MHEffectiveOnTime.FistBin: 3
|
---|
137 | MHEffectiveOnTime.NumEvents: 12000
|
---|
138 | Use FirstBin=1 and NumEvents=120 to fit the effective on time
|
---|
139 | from the resulting gamma candidates
|
---|
140 |
|
---|
141 | - star: The Center histogram in MHHillas is now by default displayed
|
---|
142 | with the colz draw-option
|
---|
143 |
|
---|
144 | - ganymed: now produces valid error codes if failed
|
---|
145 |
|
---|
146 | - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
|
---|
147 | with the option "hadronness" instead of "area" or "both" if
|
---|
148 | you want to use both cuts. The hadronness cut includes a fixed
|
---|
149 | cut in hadronness (index 8) and a fixed cut in size (index 9).
|
---|
150 |
|
---|
151 | - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
|
---|
152 | the M3Long of the anti source to be not properly evaluated
|
---|
153 | (actually is was evaluated as a unique random number) in case
|
---|
154 | of optimization with anti-theta cut switched on. This might have
|
---|
155 | lead to improper, but not necessarily wrong, optimization results.
|
---|
156 |
|
---|
157 | - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
|
---|
158 | how to use random forest
|
---|
159 |
|
---|
160 | - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
|
---|
161 | ganymed_onoff.rc. Seems to be unintentional that they were different.
|
---|
162 |
|
---|
163 | - sponde: Since the introduction of the possibility to define a
|
---|
164 | normalization energy instead of using the integral the default
|
---|
165 | was not using the integral anymore but a normalization energy of
|
---|
166 | 1GeV. It is now the integral again.
|
---|
167 |
|
---|
168 | - sponde: Fixed a problem in the weighting which did not allow
|
---|
169 | a MC slope of -1.
|
---|
170 |
|
---|
171 |
|
---|
172 |
|
---|
173 | *** Version 0.9.6 (2006/05/24)
|
---|
174 |
|
---|
175 | - general: changed the binning of the azimuthal profile of the camera
|
---|
176 | such that it is aligned with the 60deg boundaries.
|
---|
177 |
|
---|
178 | - merpp: better handling of problems with the TH, TD part of the
|
---|
179 | CC-REPORT for files older than 200507190 and 200412210
|
---|
180 | respectively
|
---|
181 |
|
---|
182 | - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
|
---|
183 |
|
---|
184 | - merpp: implementd latest changes in starguider reports (sinc 9th May)
|
---|
185 |
|
---|
186 | - callisto: if an arrival time is extracted outside the fadc range is
|
---|
187 | was set to the boundary before. Now a random number is assigned
|
---|
188 | instead to avoid unfortunate coincidences of arrival times just
|
---|
189 | by this arbitrary value.
|
---|
190 |
|
---|
191 | - callisto: added a new option to callisto.rc which allows
|
---|
192 | to set the maximum arrival time difference allowed for the
|
---|
193 | badpixel algorithm to determin whether a pixels belongs to a shower:
|
---|
194 | MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
|
---|
195 |
|
---|
196 | - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
|
---|
197 | to 0.9 as suggested by Stefan due to a recent study on the fraction
|
---|
198 | of pixels surviving the image cleaning
|
---|
199 |
|
---|
200 | - callisto: switched off error in case of "pulse is too much to the left"
|
---|
201 |
|
---|
202 | - callisto: The extraction window is not adapted anymore. This means that
|
---|
203 | the pulse is extracted from the full range. The draw-back is that the
|
---|
204 | background (pedestal) will become slightly higher. Switching on/off
|
---|
205 | the PulsePosCheck in the callisto.rc only effects filling the
|
---|
206 | histograms.
|
---|
207 | WARNING: If the pulse is too much to the left data is calibrated!
|
---|
208 | Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
|
---|
209 | in the database to make sure that your data is valid!
|
---|
210 |
|
---|
211 | - star: Show also the number of stars correlated correctly by the
|
---|
212 | starguider
|
---|
213 |
|
---|
214 | - ganymed: implemented a new class (MHThetaSqN) which allows to use more
|
---|
215 | than one off-source region in wobble-mode. To use it add the following to
|
---|
216 | your ganymed_wobble.rc:
|
---|
217 | + MJCut.NameHist: MHThetaSqN (switch the new feature on)
|
---|
218 | + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
|
---|
219 | + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
|
---|
220 | + Cut1.ThetaCut: None
|
---|
221 | + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
|
---|
222 |
|
---|
223 | - ganymed: in the case the latest report is older than a default (currently
|
---|
224 | one minute) and the current report will be skip the starguider
|
---|
225 | correction and calibration will be reset. The maximum age can be
|
---|
226 | setup from ganymed.rc by (minutes):
|
---|
227 | MPointingDevCalc.MaxAge: 1.5
|
---|
228 |
|
---|
229 | - ganymed: A first implementation showing all size-bins for the theta-sq
|
---|
230 | resp. alpha-plots in a single tab automatically
|
---|
231 |
|
---|
232 |
|
---|
233 |
|
---|
234 | *** Version 0.9.5.1 (2006/05/05)
|
---|
235 |
|
---|
236 | - general: Added a new option "zdiff" to the Makefile which runs
|
---|
237 | "cvs diff" as "make diff" would do, but with compression
|
---|
238 |
|
---|
239 | - general: accelerated MTFillMatrix (used for eample in all training
|
---|
240 | and optimization macros) by skipping some obsolete calles in the
|
---|
241 | eventloop the first and second loop could be accelerated by ~20%
|
---|
242 |
|
---|
243 | - general: Added a missing feature in the MFilterList class which
|
---|
244 | prevented MFEnergySlope from working correctly in trainenergy.C
|
---|
245 |
|
---|
246 | - general: Accelerated the random forest training and usage a bit
|
---|
247 |
|
---|
248 | - merpp: Adapted to new raw data file format version 6
|
---|
249 |
|
---|
250 | - merpp: fixed a problem with reading the starguider reports
|
---|
251 | after 6.3.2006
|
---|
252 |
|
---|
253 | - callisto: At some times six pixels had to be exchanged manually in the
|
---|
254 | data. If the pixels to be swaped are both not found, an error was raised
|
---|
255 | and calibration was stopped. Now it is assumed they are intentially not
|
---|
256 | mapped and the Error has been changed to a Warning.
|
---|
257 |
|
---|
258 | - star: Added new image cleaning based on the arrival time of the shower.
|
---|
259 | The new cleaning can be accessed using the parameter "Time" instead of
|
---|
260 | the the old one (like "Absolute) in the star.rc-file.
|
---|
261 | Recommended parameters:
|
---|
262 | + MImgCleanStd.CleanLevel1: 8.2
|
---|
263 | + MImgCleanStd.CleanLevel2: 5
|
---|
264 | + MImgCleanStd.CleanRings: 2
|
---|
265 | + MImgCleanStd.KeepSinglePixels: No
|
---|
266 |
|
---|
267 | - star: Simplified the calculation of the effective on time. By letting
|
---|
268 | the fit start in the third bin the result should become more stable.
|
---|
269 | The fit quality is now ignored for the theta-plot which is not used
|
---|
270 | in the analysis later. Still better pre-cut which, for example,
|
---|
271 | remove events triggered by car-light (rate changing on a short
|
---|
272 | time-scale) are missing.
|
---|
273 |
|
---|
274 | - macros: optimonoff.C, optimwobble.C: implemented a new strategy
|
---|
275 | for optimization (kWeakSource) which is suggested by the Berlin
|
---|
276 | people for weak sources.
|
---|
277 |
|
---|
278 | - macros: plotdb.C:
|
---|
279 | + if no dataset and no time-interval is given only sequences with
|
---|
280 | an effective on-time above five minutes are plotted anymore
|
---|
281 | + added a new tab "RelTime" displaying the relative on-time
|
---|
282 | (effective on-time divided by the observation time)
|
---|
283 |
|
---|
284 | - macros: optim*.C: by skipping some obsolete calles in the eventloop
|
---|
285 | the optimization became a lot faster
|
---|
286 |
|
---|
287 | - ganymed: In the second loop the MHNewImagePar histograms disapeared.
|
---|
288 | To display them just delete the pads displayed on top.
|
---|
289 |
|
---|
290 | - ganymed: fixed a bug which could cause strange behaviour in wobble
|
---|
291 | mode if no starguider information was available due to an incorrect
|
---|
292 | initialization of the starguider calibration
|
---|
293 |
|
---|
294 | - ganymed: The scale region in the False Source Plot (MHDisp) can now
|
---|
295 | be changed from within the plot. It can also be setup from the
|
---|
296 | resource file using:
|
---|
297 | + MHDisp.fScaleMin: 0.325
|
---|
298 | + MHDisp.fScaleMax: 0.475
|
---|
299 |
|
---|
300 | - ganymed, showplot: Fixed a problem with the fit to the off-data
|
---|
301 | (HistOff) which could cause a time lag or an inifinite loop.
|
---|
302 | The bug did not effect the results at all.
|
---|
303 |
|
---|
304 | - sponde: Added a new tab showing the effective collection area after
|
---|
305 | trigger (including the software trigger)
|
---|
306 |
|
---|
307 | - sponde: MMcSpectrumWeight has a new option which allows to define
|
---|
308 | the scaling factor not by the integral of the events but at
|
---|
309 | a defined energy:
|
---|
310 | e.g. MMcSpectrumWeight.NormEnergy: 200
|
---|
311 |
|
---|
312 | - MTFillMatrix, sponde: by skipping some obsolete calles in the
|
---|
313 | eventloops the loop could be accelerated by ~20%
|
---|
314 |
|
---|
315 |
|
---|
316 |
|
---|
317 | *** Version 0.9.5 (2006/03/13)
|
---|
318 |
|
---|
319 | - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
|
---|
320 | and added the standard Disp-parametrization
|
---|
321 |
|
---|
322 | - macros: added a new macro datacenter/macros/plotstat.C allowing
|
---|
323 | to plot statistics about the data processing
|
---|
324 |
|
---|
325 | - macros: added a new macro to plot the muon correction coefficients
|
---|
326 | versus period (macros/plot/mucal.C)
|
---|
327 |
|
---|
328 | - showplot: path inflation for ganymed files was broken
|
---|
329 |
|
---|
330 | - callisto: Fixed an important bug. When the number of saturating pixels
|
---|
331 | were calculated the bad pixel information already available from the
|
---|
332 | calibration was ignored. This yields wrong values in case pixels
|
---|
333 | are broken and saturate all the time or randomly.
|
---|
334 |
|
---|
335 | - callisto: Updated Muon calibration constants. Spline data now also uses
|
---|
336 | different values for different periods
|
---|
337 |
|
---|
338 | - star: The time-evolution shown in the effective on-time plot now displays
|
---|
339 | the axis range (if there are no holes it should be similar to the
|
---|
340 | effective on-time)
|
---|
341 |
|
---|
342 | - star: Added two new image parameters:
|
---|
343 | + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
|
---|
344 | the three pixels next to the center of gravity and the size
|
---|
345 | + MNewImagePar.fConcCore: The ratio of the signals of all
|
---|
346 | pixels inside or touching the ellipse and the size
|
---|
347 |
|
---|
348 | - ganymed: now stops in requested source isn't found in catalog file
|
---|
349 |
|
---|
350 | - ganymed: Many improvements to the phi-plot in wobble mode:
|
---|
351 | + with a template the ideal background is displayed
|
---|
352 | + a possible camera inhomogeneity is taken into account
|
---|
353 | + the anti theta cut is better supported
|
---|
354 | + the phi cut is automatically calculated from the theta cut
|
---|
355 | See the examples in ganymed_wobble.rc for more details.
|
---|
356 |
|
---|
357 | - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
|
---|
358 | times the bin-width instead of the absolute energy
|
---|
359 |
|
---|
360 | - ganymed: New cuts for on/off and wobble mode
|
---|
361 |
|
---|
362 | - ganymed: The smearing of the False Source plot has been increased
|
---|
363 | to 0.06
|
---|
364 |
|
---|
365 | - ganymed: The starguider calibration can now be changed from the
|
---|
366 | resource file.
|
---|
367 | See the examples in ganymed*.rc for more details.
|
---|
368 |
|
---|
369 | - ganymed: added a new option for on-/off-observations
|
---|
370 | MJCut.RandomSourcePosition
|
---|
371 | If switched on the distribution of observation time of the source
|
---|
372 | position in the camera is calculated from the on-data and randomly
|
---|
373 | applied with this distrbution to the off-data.
|
---|
374 |
|
---|
375 | - ganymed: by skipping some obsolete calles in the eventloop the
|
---|
376 | first and second loop could be accelerated by ~20%
|
---|
377 |
|
---|
378 | - ganymed: The default in ganymed_onoff.rc is now to determin the source
|
---|
379 | position in the off-data randomly according to its distribution in the
|
---|
380 | on-data.
|
---|
381 |
|
---|
382 |
|
---|
383 |
|
---|
384 | *** Version 0.9.4.3 (2006/02/13)
|
---|
385 |
|
---|
386 | - general: Fixed a bug in most of the programs which prevented the
|
---|
387 | compile date in the startup message to be displayed
|
---|
388 |
|
---|
389 | - general: Simplified program calls. The following abbreviations
|
---|
390 | are now possible:
|
---|
391 | showlog callisto 55599
|
---|
392 | showplot signal 55599
|
---|
393 | star 55599
|
---|
394 | callisto 55999
|
---|
395 | ganymed 2
|
---|
396 | In this cases the corrsponding root-, log-, sequence- or dataset-
|
---|
397 | filename is automatically compiled using the default datacenter
|
---|
398 | paths ("/magic/*")
|
---|
399 |
|
---|
400 | - general: Fixed a long outstanding bug which made axis tick marks
|
---|
401 | disappear if MDataFormula was used (eg. abs(x))
|
---|
402 |
|
---|
403 | - general: Updated MMath with new functions to calculate the results of
|
---|
404 | a exponential, logarithmic and powerlaw fits analytically.
|
---|
405 |
|
---|
406 | - general: Updated some macros with comments:
|
---|
407 | + macros/optim/optimdisp.C
|
---|
408 | + macros/optim/optimenergy.C
|
---|
409 | + macros/optim/optimwobble.C:
|
---|
410 |
|
---|
411 | - general: MTFillMatrix (the class to fill one or two MHMatrix from
|
---|
412 | files) now allows adding a pre-cut like in the optimization. E.g. this
|
---|
413 | is useful to perform g/h-separation cuts before training the random
|
---|
414 | forest.
|
---|
415 |
|
---|
416 | - general: Between the rund 53300 and 68754 the pixels 553-558 were not
|
---|
417 | correctly assigned in the raw data assignement table. A fix to correct
|
---|
418 | the assignment tabel have been implemented.
|
---|
419 |
|
---|
420 | - general: MAstroCatalog now allows rotating of the sky-grid and stars
|
---|
421 | by 90, 180 and 270 deg.
|
---|
422 |
|
---|
423 | - general: the macro plotdb.C now allows to highlight sequences belonging
|
---|
424 | to a datset. For more details see the descritions in the macro.
|
---|
425 |
|
---|
426 | - StatusDisplay: Fixed the algorithm to calculate the size ratio
|
---|
427 | of the display, it gave wrong results espacially for big sizes.
|
---|
428 | Now the embedded canvas should always have a ratio width/height=3/2.
|
---|
429 | The "Size" options have been updated with values fitting the 3/2
|
---|
430 | size ratio.
|
---|
431 |
|
---|
432 | - RanForest:
|
---|
433 | + Updated the random forest classes to support also the
|
---|
434 | regression method implemented by Thomas H.
|
---|
435 | + added new tutorial macro how to train the random forest
|
---|
436 | for energy estimation (macros/optim/rfenergyest.C)
|
---|
437 | + new classes to train the random forest (still in development)
|
---|
438 | mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
|
---|
439 | + new tutorial macros for random forest training in macros/train
|
---|
440 | trainenergy.C, traindisp.C, trainseparation.C
|
---|
441 |
|
---|
442 | - mars: now allows to setup a cut in the resource file mars.rc to choose
|
---|
443 | the events to be displayed, eg:
|
---|
444 | Cut.Condition: {0} && {1}
|
---|
445 | Cut.0: MHillas.fSize>100
|
---|
446 | Cut.1: MHillas.fSize<900
|
---|
447 |
|
---|
448 | - merpp: Made aware of the new .rep format 200510250. This includes
|
---|
449 | interpretation of the Receiver Board Temperatures (MCameraRecTemp),
|
---|
450 | the discriminator thresholds (MCameraTD) and the disciminator
|
---|
451 | delays (MCameraTD). All of them come with the CC report and are therefor
|
---|
452 | written to the CC tree.
|
---|
453 |
|
---|
454 | - callisto: fixed a bug in the calculation of the arrival times in
|
---|
455 | the Digital Filter. They were all shifted by the same amount
|
---|
456 | fHiGainFirst. This caused an offset in the order of the position of
|
---|
457 | the left border of the extraction window in the times calculated
|
---|
458 | from high-gain and from low-gain. The bug effected only the absolute
|
---|
459 | arrival times. The bug was there since 30.1.2005.
|
---|
460 |
|
---|
461 | - callisto: Changed the ExtractionWindow for the pulse position check
|
---|
462 | such that the camera inhomogeneity becomes as less as possible and
|
---|
463 | comparable to the pulso position check switched off. More details
|
---|
464 | on the study will be given at our result web-page.
|
---|
465 |
|
---|
466 | - ganymed: ganymed.rc, ganymed_onoff.rc:
|
---|
467 | changed to new cuts trained with 1ES1218 and Crab-data
|
---|
468 | for maximum sigma*log10(excess)
|
---|
469 |
|
---|
470 | - ganymed: In addition to the Hadronness calculator (CalcHadronness)
|
---|
471 | a new option was implemented to estimate Disp (CalcDisp)
|
---|
472 |
|
---|
473 | - ganymed: Implemented two new options which allow
|
---|
474 | to overwrite the default path to search for the sequence files
|
---|
475 | --ins=/magic/sequences
|
---|
476 | and where to search for the image data
|
---|
477 | --ind=/magic/data/star
|
---|
478 |
|
---|
479 | - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
|
---|
480 | dx/dy from the resource file by
|
---|
481 | MSrcPosCorrect.Dx
|
---|
482 | MSrcPosCorrect.Dy
|
---|
483 |
|
---|
484 | - ganymed: fixed reading the source catalog. Only as many chars
|
---|
485 | as the requested source name had were compared (If a source
|
---|
486 | "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
|
---|
487 | were requested it could happen that the coordinates of
|
---|
488 | "1ES1218" were read) The source coordinates are now printed
|
---|
489 | in addition to its name to the logging output.
|
---|
490 |
|
---|
491 | - ganymed: changed the background fit in the case of a ThetaSq function
|
---|
492 | from a polynomial to a exponential, this should give a big improvement
|
---|
493 | for on-only analysis'
|
---|
494 |
|
---|
495 | - ganymed/sponde: Calculation of the error of single size-/energy-
|
---|
496 | bins now uses Li/Ma (5) instead of LiMa (17)
|
---|
497 |
|
---|
498 | - sponde: Added a plot E^2*dN/dE
|
---|
499 |
|
---|
500 | - sponde: The energy estimator plot should now show values like
|
---|
501 | they are commonly used.
|
---|
502 |
|
---|
503 | - sponde: Now MMcSpectrumWeight also excepts formulas with two X
|
---|
504 | (a powerlaw with cutoff didn't work before)
|
---|
505 |
|
---|
506 |
|
---|
507 |
|
---|
508 | *** Version 0.9.4.2 (2005/10/01)
|
---|
509 |
|
---|
510 | - general: added new tutorial macro macros/tutorials/threshold.C:
|
---|
511 | how to calculate the threshold
|
---|
512 |
|
---|
513 | - general: added a new game. Start it from the interpreter with
|
---|
514 | MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
|
---|
515 | and MagicReversi)
|
---|
516 |
|
---|
517 | - general: neighbor pixels in MGeoms are now sorted clockwise
|
---|
518 |
|
---|
519 | - merpp: made aware of new format 20050829-0
|
---|
520 |
|
---|
521 | - callisto: New scale factors from muon analysis, stored in new
|
---|
522 | resource file resources/calibration.rc
|
---|
523 |
|
---|
524 | - callisto: MBadPixelsCalc now raises an error instead of simply stopping
|
---|
525 | the eventloop if something went wrong. This is necessary for the
|
---|
526 | automatic processing
|
---|
527 |
|
---|
528 | - callisto: Implemented a new treatment for the time information
|
---|
529 | developed by S.Ruegamer, this should give much better response than
|
---|
530 | the old very primitive algorithm. This is especially important
|
---|
531 | for bad pixels due to bright stars as Ceta-Tauri (btw: the old
|
---|
532 | treatment was buggy! As neighbor pixels to interpolate the
|
---|
533 | arrival times always the pixels 0 to 5 were taken)
|
---|
534 |
|
---|
535 | - callisto: In addition to the new treatment of arrival times the
|
---|
536 | decision of the treatment whether a pixel contains shower
|
---|
537 | information or not is used to improve the signal interpolation
|
---|
538 | further. Previously interpolated pixels showed a non-zero signal
|
---|
539 | do the peak searching signal extractors. Having a signal pixel
|
---|
540 | beside raised the signal above the cleaning level. Thus the
|
---|
541 | pixel survived cleaning to often but with a too low mean signal.
|
---|
542 | By replacing empty pixels with a gaus (mean and rms from the
|
---|
543 | corresponding Area entries in MPedPhotCam) this effect can
|
---|
544 | be supressed.
|
---|
545 |
|
---|
546 | - callisto: The status "unmapped" (for pixel which cannot be interpolated)
|
---|
547 | got lost when the events were stored by the calibration... fixed.
|
---|
548 | (This was no problem for normal image cleaning because the pixel
|
---|
549 | content was artificially set to 0 not surviving standard cleaning
|
---|
550 | algorithm)
|
---|
551 |
|
---|
552 | - callisto: Fixed a bug which caused the random and peak-search pedestal
|
---|
553 | extracted with an extractor to be exchanged for the first (roughly)
|
---|
554 | 500 events (*Extractor and *ExtractorRndm).
|
---|
555 | (They were simply exchanged in callisto.cc) This bug might have been
|
---|
556 | introduced in Mars 0.9.4 when the order of calculation of the two
|
---|
557 | types of pedestal in callisto got exchanged. The bug only effects
|
---|
558 | the first seconds of data of each sequence.
|
---|
559 |
|
---|
560 | - star: Taking the arrival time of Muons into account the calculation
|
---|
561 | of the parameters could be made independant of the noise
|
---|
562 | (pedestal rms). The dependance was due to the bias of the peak search
|
---|
563 | extractor. Now only a ZA dependamcy is left which is not yet fully
|
---|
564 | understood.
|
---|
565 |
|
---|
566 | - ganymed: The sequences were still not sorted correctly in any case,
|
---|
567 | because they were sorted by the full qualified path name. Now they
|
---|
568 | are sorted by their sequence number.
|
---|
569 |
|
---|
570 | - ganymed: new values for the spark-event-cut
|
---|
571 |
|
---|
572 | - sponde: required missing MEnergyEst from ganymed.root... fixed.
|
---|
573 |
|
---|
574 |
|
---|
575 |
|
---|
576 | *** Version 0.9.4.1 (2005/08/18)
|
---|
577 |
|
---|
578 | - callisto: fixed some problems with the calibration in case of
|
---|
579 | inteleaved events. Therefor the final and some intermediate
|
---|
580 | fits are skipped which would take place on partly filled #
|
---|
581 | histograms and gave wrong results or failed completely.
|
---|
582 |
|
---|
583 | - callisto: If the intermediate finalization of the histograms
|
---|
584 | calculating the mean charge of the calibration signal fails
|
---|
585 | it is counted now and printed in PostProcess of MCalibCalcFromPast.
|
---|
586 |
|
---|
587 | - ganymed: Fixed some bugs which caused problems in On-only mode.
|
---|
588 | Still the false source plot doesn't give reasonable results.
|
---|
589 |
|
---|
590 |
|
---|
591 |
|
---|
592 | *** Version 0.9.4 (2005/08/05)
|
---|
593 |
|
---|
594 | - general: Fixed the ZA binning. It did not correctly fit the
|
---|
595 | MC binning
|
---|
596 |
|
---|
597 | - general: Added a class to correct for the missfocussing in
|
---|
598 | April (MSrcPosCorrect)
|
---|
599 |
|
---|
600 | - general: Random Forest energy estimator should now work properly
|
---|
601 |
|
---|
602 | - general: MHCamera now displays the profiles in deg instead of mm
|
---|
603 |
|
---|
604 | - general: MH::SetPalette offers a lot of new palettes
|
---|
605 |
|
---|
606 | - general: MHillas - the case of CorrXY==0 is now handled properly
|
---|
607 |
|
---|
608 | - general: implemented the possibility to change the line and
|
---|
609 | marker style of a sky-grid drawn by MAstroCatalog
|
---|
610 |
|
---|
611 | - general: Runs in sequences and datasets are now automatically
|
---|
612 | ordered (it is assumed that the order of their filenames correctly
|
---|
613 | represents the order of observations) to ensure correct reading
|
---|
614 | of the subsystem data
|
---|
615 |
|
---|
616 | - general: Runs cannot be added to a sequence twice anymore. Also
|
---|
617 | Sequences cannot be added twice anymore to a dataset.
|
---|
618 |
|
---|
619 | - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
|
---|
620 | It gave wrong results by 1./2pi
|
---|
621 |
|
---|
622 | - showplot: got a new option to start a root interpreter, too
|
---|
623 |
|
---|
624 | - mars: now displays a rough estimate of Disp and the third moment
|
---|
625 |
|
---|
626 | - mars: now displays the event time MTime if available
|
---|
627 |
|
---|
628 | - mars: show muon parameters graphically
|
---|
629 |
|
---|
630 | - mars: now the file to open can be given as commandline
|
---|
631 | argument
|
---|
632 |
|
---|
633 | - merpp: Added support for new arehucas version >= 200507190
|
---|
634 | implementing values for three temperature sensors in the
|
---|
635 | counting house (MCameraAUX) and the name of the HV settings file
|
---|
636 | (MCameraHV).
|
---|
637 |
|
---|
638 | - merrp: Also fixed some problems with wrong versions numbers stated
|
---|
639 | by arehucas and implemented some fixed for old versions (<200407070)
|
---|
640 |
|
---|
641 | - callisto: MCalibrationHiLoCam can now be printed from its context
|
---|
642 | menu, eg in the TBrowser
|
---|
643 |
|
---|
644 | - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
|
---|
645 | - 1.39 (MExtractTimeAndChargeSpline)
|
---|
646 | - 1.40 (MExtractTimeAndChargeDigitalFilter)
|
---|
647 | This is important mainly for timing studies.
|
---|
648 |
|
---|
649 | - callisto: Changed limits in MHCalibrationChargeCalc from
|
---|
650 | - -100.125 to -98 (fgChargeHiGainFirst)
|
---|
651 | - 1899.875 to 1902. (fgChargeHiGainLast)
|
---|
652 | - -100.25 to -99 (fgChargeLoGainFirst)
|
---|
653 | - 899.75 to 901. (fgChargeLoGainLast)
|
---|
654 | Introduced new limits:
|
---|
655 | - fgNumLoGainBlackoutLimit: 0.05
|
---|
656 | - fgLoGainBlackoutLimit: 3.5
|
---|
657 | - fgLoGainPickupLimit: 3.5
|
---|
658 |
|
---|
659 | - callisto: The handling of automatic weights for the digital filter
|
---|
660 | has been improved. There are now new calibration weights special
|
---|
661 | for Monte Carlo calibrations.
|
---|
662 |
|
---|
663 | - callisto: Updated Muon scale with latest results (1% difference
|
---|
664 | for most data, 5% for Mar/Apr'05)
|
---|
665 |
|
---|
666 | - callisto: use a new criterium to exclude bad pixels: If the high-gain
|
---|
667 | was saturated and the blackout-events in the low-gain exceed the
|
---|
668 | fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
|
---|
669 | This excludes those pixels which have a saturating high-gain
|
---|
670 | channel, but the low-gain switch does not switch often enough
|
---|
671 | to make the distribution reliable.
|
---|
672 |
|
---|
673 | - callisto: fix a bug counting the number of saturated events. Up to now,
|
---|
674 | the number of saturated slices was counted (which is one for a not too
|
---|
675 | high number), but for some (pathological) pixels, many more slices
|
---|
676 | saturated and produced wrong limits.
|
---|
677 |
|
---|
678 | - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
|
---|
679 | + MCalibrationRelTimeCam.CheckFitResults: Yes
|
---|
680 | + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
|
---|
681 | + MCalibrationRelTimeCam.CheckHistOverflow: Yes
|
---|
682 | + MCalibrationRelTimeCam.CheckOscillations: Yes
|
---|
683 |
|
---|
684 | - callisto: introduce max. number of events for intercalibration,
|
---|
685 | the rest gets skipped. Default: 4096
|
---|
686 | The calibration causes too many un-reliable pixels if more
|
---|
687 | than about 5000 events are treated (@500 Hz) because of the
|
---|
688 | mode hopping of the VCSels. However, in the past, some
|
---|
689 | calibration runs have been taken (erroneously) with more
|
---|
690 | than 5000 events, especially the intensity scans where
|
---|
691 | a good precision is needed.
|
---|
692 |
|
---|
693 | - callisto: Set UseExtractorRes to kTRUE, will raise the number of
|
---|
694 | photo-electrons for the spline extractor by 1-2% (correctly).
|
---|
695 |
|
---|
696 | - callisto: The intercalibration is now done using a full f-factor
|
---|
697 | method instead of a simple update. This makes things slower but
|
---|
698 | more reliable in terms of gain-fluctuations and sudden VCSEL gain
|
---|
699 | changes.
|
---|
700 |
|
---|
701 | - callisto: MPedestalY3 now uses the same extraction range as the data
|
---|
702 | as calculated by MPedestalY2
|
---|
703 |
|
---|
704 | - callisto: A check of the fraction of allowed unsuitable (10%) and
|
---|
705 | unreliable (30%) pixels has been addded when the conversion is
|
---|
706 | calculated from interleaved events
|
---|
707 |
|
---|
708 | - star: fixed a bug which caused MEffectiveOnTime containers not to
|
---|
709 | be written. In the worst case they were skipped almost all, in the
|
---|
710 | best case they were all ok. It depends on how often the new value
|
---|
711 | was assigned just with an event which was skipped later by another
|
---|
712 | task
|
---|
713 |
|
---|
714 | - star: new histograms MHPointing and MHRate
|
---|
715 |
|
---|
716 | - star: New tab (Currents) displaying the time evolution of the mean
|
---|
717 | DC currents
|
---|
718 |
|
---|
719 | - star: New tab (MeanRms) displaying the time volution of the mean
|
---|
720 | Pedestal Rms
|
---|
721 |
|
---|
722 | - star: Output now contains MReportStarguider
|
---|
723 |
|
---|
724 | - star: Improved muon analysis. Due to the absense of a constant
|
---|
725 | for the gaus fit for arc width and the fact that the arcwidth
|
---|
726 | plot was a histogram instead of a profile the resulting psf
|
---|
727 | became pedestal rms dependant
|
---|
728 |
|
---|
729 | - ganymed: added new plot (MHPhi) for wobble mode as described in
|
---|
730 | http://www.astro.uni-wuerzburg.de/results/ringmethod/
|
---|
731 |
|
---|
732 | - ganymed: corrects now (correctly?) for the misspointing in
|
---|
733 | May/April 05
|
---|
734 |
|
---|
735 | - ganymed: Two new default templates for ganymed.rc are avilable:
|
---|
736 | ganymed_onoff.rc and ganymed_wobble.rc
|
---|
737 |
|
---|
738 | - ganymed: The first version of MFMagicCuts has been released
|
---|
739 |
|
---|
740 | - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
|
---|
741 |
|
---|
742 | - ganymed, sponde: There are two new options to determin the number
|
---|
743 | of bins for the signal region (NumBinsSignal) and the number of
|
---|
744 | total bins (NumBinsTotal) in the MHThetaSq histogram
|
---|
745 |
|
---|
746 | - ganymed: optimized palettes for MHDisp
|
---|
747 |
|
---|
748 | - ganymed: Fixed an important bug when using ThetaSq as fit function:
|
---|
749 | The result for the sigma of the gauss(sqrt(x)) fit was a factor
|
---|
750 | sqrt(2) to large
|
---|
751 |
|
---|
752 | - ganymed: The false source plot (MHDisp) is now based on Disp
|
---|
753 | and a background model determined in the first loop is
|
---|
754 | subtracted
|
---|
755 |
|
---|
756 | - ganymed: MFMagicCuts are now available in the cvs. The correct
|
---|
757 | solution for the disp ambiguity problem is now calculated using
|
---|
758 | the third moment. The third moment cut therefor is skipped.
|
---|
759 |
|
---|
760 | - ganymed: Output now contains "Disp [MParameterD]" which sign is
|
---|
761 | already determined by the third moment along the major axis and
|
---|
762 | so its actual sign is aligned along the major axis of the shower.
|
---|
763 |
|
---|
764 | - ganymed: If starguider data is available it is taken into account
|
---|
765 | when calculating the source position. This is especially important
|
---|
766 | for wobble data at high zenith angles and culmination data.
|
---|
767 |
|
---|
768 | - ganymed: If available the starguider data is taken into account as
|
---|
769 | good as it is possible without a starguider calibration. To switch
|
---|
770 | it off add
|
---|
771 | MPointingDevCalc.MaxAbsDev: -1
|
---|
772 | to your ganymed.rc
|
---|
773 |
|
---|
774 | - sponde: the zenith angle distribution is now weighted instead of
|
---|
775 | choosen by default. This gurantees higher statistics in the highest
|
---|
776 | and lowest energy bins. To switch this behaviour off use...
|
---|
777 |
|
---|
778 | - sponde: now automatically displays the energy threshold
|
---|
779 |
|
---|
780 |
|
---|
781 |
|
---|
782 | *** Version 0.9.3 (2005/06/03)
|
---|
783 |
|
---|
784 | - general: MMcEvt now derived from MMcEvtBasic which should
|
---|
785 | have no influence on compatibility with older camera files
|
---|
786 |
|
---|
787 | - general: Implemented a new option to MReadReports which allows
|
---|
788 | to force reading of the first event of some trees (eg. Drive-tree)
|
---|
789 | before any other tree.
|
---|
790 |
|
---|
791 | - general: Made a fix to MPointingPosCalc which assumes that the
|
---|
792 | run-type is real-data if Process is called before ReInit, such
|
---|
793 | that also the very first Drive-events in a run are treated
|
---|
794 | correctly.
|
---|
795 |
|
---|
796 | - shoplot now displays the filename in the title bar of the window
|
---|
797 |
|
---|
798 | - merpp: new options: --auto-time-start --auto-time-stop which
|
---|
799 | allow to cut updating with slow-control at the start- or
|
---|
800 | (previousle --auto-time only allowed: and) stop-time of
|
---|
801 | the run stored in the runheader.
|
---|
802 |
|
---|
803 | - callisto: changed default of fgFallTimeHiGain in
|
---|
804 | MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
|
---|
805 | already set as default in callisto_Dec04Jan05.rc
|
---|
806 |
|
---|
807 | - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
|
---|
808 | now changes the filename for new weights automatically for
|
---|
809 | cosmics, MC and for different calibration colors.
|
---|
810 |
|
---|
811 | - callisto: a problem with the order of some code cause the
|
---|
812 | name of the weights file in MPedestalY2 to be ignored.
|
---|
813 | Wrongly the calibration_UV weights were used instead
|
---|
814 | of the cosmics weights set in callisto.rc.
|
---|
815 |
|
---|
816 | - callisto: should allow ct1 pulser data when the color is
|
---|
817 | explicitly set also for pretty new runs
|
---|
818 |
|
---|
819 | - callisto: a new option (MCalibrateData.ScaleFactor) allows
|
---|
820 | to introduce an additional scale factor (should be around 1)
|
---|
821 | to adapt for slight deviations in different extractors from
|
---|
822 | the MC calibration. For MC calibrations the scale factor
|
---|
823 | is fixed to 1
|
---|
824 |
|
---|
825 | - callisto: MFCosmics should handle very high signals a bit
|
---|
826 | more accurate now
|
---|
827 |
|
---|
828 | - callisto: when calculating the mean pedestal rms for different
|
---|
829 | pixel sizes or sectors also kUnsuitableEvt is now taken into
|
---|
830 | account - not only kUnsuitableRun
|
---|
831 |
|
---|
832 | - callisto: '-raw' option is now the default
|
---|
833 |
|
---|
834 | - callisto: A dead pixel check has been implemented in MJPedestalC2.
|
---|
835 | This has the advantage that mean values in the calibration (eg
|
---|
836 | arrival times) are calculated more accuratly.
|
---|
837 |
|
---|
838 | - callisto: In the resource file callisto_Dec04Jan05.rc
|
---|
839 | MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
|
---|
840 |
|
---|
841 | - callisto: new Hi-/Lo-Gain intercalibration constants
|
---|
842 | hilocalib_sp1.root and hilocalib_sp1_mc.root
|
---|
843 |
|
---|
844 | - callisto: changed default for MJPedestalY2.MaxEvents
|
---|
845 | from 2000 to 5000 like in callisto_Dec04Jan05.txt
|
---|
846 |
|
---|
847 | - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
|
---|
848 | has changed from 9.0 to 6.0. This is necessary to exclude two very
|
---|
849 | ringing pixels in September which - when kept - destroy the image
|
---|
850 | cleaning around them (Markus G.)
|
---|
851 |
|
---|
852 | - callisto: (!) The Muon analysis of all data taken so far has
|
---|
853 | suggested that different extractors give slightly different
|
---|
854 | absolute results after calibration, due to there different
|
---|
855 | handling of the calibration- and cosmics pulse shape. Although
|
---|
856 | the over all calibration seems to be a bit to pesimistic (or
|
---|
857 | the MC seems to be a little bit - 3-5% - too much attenuated).
|
---|
858 | There for correction factors have been introduced which correct
|
---|
859 | the calibration constants by
|
---|
860 | 0.956937799 for Digital Filter (callisto.rc)
|
---|
861 | and
|
---|
862 | 0.904159132 for Spline (callisto_Dec04Jan05.rc)
|
---|
863 | calibration. The main advantage is, that both data types can
|
---|
864 | be easily analysed together and compared to the same MC sample.
|
---|
865 | The factors are choosen such, that the reference is now a
|
---|
866 | Monte Carlo sample calibrated with Digital Filter (callisto.rc)
|
---|
867 |
|
---|
868 | - star: fixed a bug which caused the first bin of the histograms
|
---|
869 | vs time to disapear in PostProcess. This gave wrong results
|
---|
870 | on the screen. The output and all following programs not
|
---|
871 | directly accessing the histograms haven't been affected
|
---|
872 |
|
---|
873 | - star, ganymed: Made sure that always the first Drive-tree event
|
---|
874 | is read and Processed before the first data event was read.
|
---|
875 |
|
---|
876 | - ganymed: implemented the possibility to replace the standard
|
---|
877 | false source plot with a different one. For example: If
|
---|
878 | you want to use a Disp based FS plot use the resource:
|
---|
879 | NameHistFS: MHDisp
|
---|
880 | For details about the requirements of these plots look
|
---|
881 | at the corresponding classes
|
---|
882 |
|
---|
883 | - MJOptimize: For On/Off and Wobble optimization MJOptimize
|
---|
884 | has been replaced by MJOptimizeCuts. To use MHThetaSq instead
|
---|
885 | of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
|
---|
886 | case MAlphaFitter is setup correctly. For On-Only optimization
|
---|
887 | MJOptimize has been Replaced by MJOptimizeCuts, too. Call
|
---|
888 | RunOn() instead of Run(). For energy estimation MJOptimize
|
---|
889 | has been replaced by MJOptimizeEnergy
|
---|
890 |
|
---|
891 | - sponde: The input MC spectrum can now be weighted to fake a
|
---|
892 | different spectrum. This is done via MMcSpectrumWeight. For
|
---|
893 | more details see the class description and sponde.rc
|
---|
894 |
|
---|
895 | - sponde: The paremeter comparsion plots are not scaled by
|
---|
896 | their entries anymore. Instead the MC plot is scaled by using
|
---|
897 | the result spectrum of the analysis. If the input MC spectrum
|
---|
898 | and the result spectrum has different slopes the absolut
|
---|
899 | normalization is normally wrong.
|
---|
900 |
|
---|
901 |
|
---|
902 |
|
---|
903 | *** Version 0.9.2 (2005/05/20)
|
---|
904 |
|
---|
905 | - general: Changed the default paths for calibrated data and image
|
---|
906 | files. (The implemented access to these files doesn't yet exist)
|
---|
907 |
|
---|
908 | - general: support for MRunIter has been removed from the job classes
|
---|
909 | (use the setter functions of MSeqeunce instead)
|
---|
910 |
|
---|
911 | - general: ProcessFile has been renamed to Process in all job classes,
|
---|
912 | because ProcessFile is missleading
|
---|
913 |
|
---|
914 | - general: The storage of the palette in MHCamera is now possible
|
---|
915 |
|
---|
916 | - general: new bits describing unsuitable and unreliable pixels have
|
---|
917 | been introduced in MBadPixelsPix: kPreviouslyExcluded,
|
---|
918 | kDeadPedestalRms, kFluctuatingArrivalTimes
|
---|
919 |
|
---|
920 | - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
|
---|
921 | versions newer than V200404070
|
---|
922 |
|
---|
923 | - general: support for cc file versions newer than V200504130. Added
|
---|
924 | support for active loads (MCameraActiveLoad) and central pixel
|
---|
925 | (MCameraCentralPixel)
|
---|
926 |
|
---|
927 | - general: added new histograms for image parameters versus size
|
---|
928 | (MHVsSize)
|
---|
929 |
|
---|
930 | - general: The eventloop now automatically calls PrintStatistics
|
---|
931 |
|
---|
932 | - Status Display: Improved support for printing:
|
---|
933 | + A default can now be set in .rootrc (for more details see
|
---|
934 | MStatusDisplay::PrintPS)
|
---|
935 | + A print dialog is opened so that printer and command line
|
---|
936 | can be canged
|
---|
937 |
|
---|
938 | - showlog: improved such that it handles different verbosity levels
|
---|
939 | more accurate now. This mean you can suppress output when
|
---|
940 | using showlog.
|
---|
941 |
|
---|
942 | - showplot: improved
|
---|
943 | + The new graphics formats have been implemented
|
---|
944 | (pdf, svg, png, jpg and xpm)
|
---|
945 | + Implemented an interface for printing. Because you can change
|
---|
946 | the printing command from the command line you can use all
|
---|
947 | the nice postscript tool. To print a booklet for example call:
|
---|
948 | showplot -b --print --print-cmd="cat %f" filename.root | lpr
|
---|
949 | showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
|
---|
950 | showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
|
---|
951 |
|
---|
952 | - callisto: fixed a bug in the recognition of the calibration bit
|
---|
953 | pattern. Concerns only intensity calibration. (The strength of the
|
---|
954 | intensity has been updated in some cases)
|
---|
955 |
|
---|
956 | - callisto: add a filter against PIN Diode events when running over
|
---|
957 | calibration runs since some of the recent calibration runs have
|
---|
958 | been taken with Pin Diode.
|
---|
959 |
|
---|
960 | - callisto: added support for the runs 39942, 39944, 44834, 39941,
|
---|
961 | 39943, 44833 in the calibration (MCalibColorSet)
|
---|
962 |
|
---|
963 | - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
|
---|
964 | been set to 1e-18 in callisto_Dec04_Jan05.rc
|
---|
965 |
|
---|
966 | - callisto: in callisto_Dec04Jan05.rc: set value for
|
---|
967 | MJPedestalY2.MaxEvents from 2000 to 5000 to get better
|
---|
968 | statistics for the calculation of the mean pulse time
|
---|
969 | of the cosmisc
|
---|
970 |
|
---|
971 | - callisto: the charge limit in the calibration has been raised
|
---|
972 | from 2.5 to 4.5
|
---|
973 |
|
---|
974 | - callisto: new setup read from callisto.rc
|
---|
975 | + MCalibCalcFromPast.fNumEventsDump
|
---|
976 | + MHCalibrationChargeCam.NumHiGainSaturationLimit
|
---|
977 | + MHCalibrationChargeCam.NumLoGainSaturationLimit
|
---|
978 |
|
---|
979 | - callisto: MExtractTimeAndChargeSpline extractor:
|
---|
980 | + The integration ranges were shifted by 0.2 FADC slices to the right.
|
---|
981 | + unreliable handling of floating point values caused different
|
---|
982 | results on different platform or with different compiler options:
|
---|
983 | The new algorithm is numerically exact and more accurate because
|
---|
984 | it doesn't calculate the integration position by multiple times
|
---|
985 | adding the step-size (which results in numerical uncertanties
|
---|
986 | exspecially if multiplied with large numbers)
|
---|
987 | + A lot of fixes have been introduced which effects integrating the
|
---|
988 | spline at the edges of the valid range. In this case any memory
|
---|
989 | was randomly accessed. This behaviour can be tested replacing
|
---|
990 | all MArrayF by TArrayF which perform a range check (but of course
|
---|
991 | they are a lot slower)
|
---|
992 | ! No result obtained with the Spline before can be trusted! Due to
|
---|
993 | random memory access it might by completely random!
|
---|
994 |
|
---|
995 | - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
|
---|
996 | + extraction range in the high gain to 4.
|
---|
997 | + weights file to cosmics_weights46.dat
|
---|
998 |
|
---|
999 | - callisto:
|
---|
1000 | + introduce the check for fluctuating arrival times.
|
---|
1001 | + set charge limit to from 2.5 to 4.5
|
---|
1002 | + introduce asymmetric exclusion due to "deviating number of phes":
|
---|
1003 | Default: -9.0 +4.5
|
---|
1004 | + make deviating number of phes unsuitable (see David's findings).
|
---|
1005 |
|
---|
1006 | - callisto: fixed the display of unsuitable pixels. The old change
|
---|
1007 | to a real profile in MHCamera broke it.
|
---|
1008 |
|
---|
1009 | - callisto: The cosmics filter is used in MJCalibration now
|
---|
1010 | independant of the pulser color (formaly it was used only for
|
---|
1011 | CT1-pulser data). The threshold of number of max empty pixels
|
---|
1012 | has been raised from 2% to 5% in MJCalibration. The maximum
|
---|
1013 | fraction of rejected event is 50% otherwise the calibration has
|
---|
1014 | failed. The filter now ignores unsuitable pixels.
|
---|
1015 | Setup the filter from callisto.rc using "ContCosmics"
|
---|
1016 | (see MFCosmics::ReadEnv)
|
---|
1017 |
|
---|
1018 | - callisto: changed default for fgOffsetFromLogain back
|
---|
1019 | from -2.8 to -1.8 in digital filter.
|
---|
1020 |
|
---|
1021 | - callisto: for the common extractors
|
---|
1022 | + MExtractFixedWindow
|
---|
1023 | * MExtractTimeAndChargeSlidingWindow
|
---|
1024 | * MExtractTimeAndChargeSpline
|
---|
1025 | * MExtractTimeAndChargeDigitalFilter
|
---|
1026 | the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
|
---|
1027 | and fResolutionPerPheLoGain
|
---|
1028 |
|
---|
1029 | - callisto: Updated the hi-/lo-gain intercalibration constants
|
---|
1030 | hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
|
---|
1031 | hilocalib_df6.root
|
---|
1032 |
|
---|
1033 | - callisto: The default lo-gain extraction window for the
|
---|
1034 | MExtractTimeAndChargeSlidingWindow extractor has been increased
|
---|
1035 | from 6 to 8 to take the stretch of the pusle into account
|
---|
1036 |
|
---|
1037 | - callisto (!!!): fixed an important bug in the setting of the
|
---|
1038 | incoming pedestal pointer to the signal extractor extracting
|
---|
1039 | pedestals. This bug caused the pedestals not to be subtracted
|
---|
1040 | correctly in the calibration afterwards. The effect was about 10%
|
---|
1041 | too high conversion factors for the digital filter and the spline
|
---|
1042 | and more than 40% for the sliding window.
|
---|
1043 | The bug existed since end of February! (Markus G.)
|
---|
1044 |
|
---|
1045 | - star: added muon support to star. A new tab "MHMuonPar" is
|
---|
1046 | displayed. The lower right plot is an estimate of the point spread
|
---|
1047 | function. A reference value is displayed. To get the real PSF
|
---|
1048 | you must compare with MC. The setup for the muon analysis
|
---|
1049 | is done in star.rc. More informations can be found in
|
---|
1050 | MHSingleMuon and MHCalibParCalc
|
---|
1051 |
|
---|
1052 | - star: The weather data is now displayed in star
|
---|
1053 |
|
---|
1054 | - star: MEventRateCalc handles the calculation of the event rate more
|
---|
1055 | accurate now in case of the start of a new run inside a sequence
|
---|
1056 |
|
---|
1057 | - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
|
---|
1058 | from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
|
---|
1059 | changed only minimally
|
---|
1060 |
|
---|
1061 | - ganymed: (MJCut and MJOptimize) now displayes the number of
|
---|
1062 | excess events versus size. The energy estimation is done in
|
---|
1063 | MJSpectrum (sponde)
|
---|
1064 |
|
---|
1065 | - ganymed: got support for using other variables than Alpha, eg. Theta.
|
---|
1066 | Therefor you need a class deriving from MHAlpha which supports
|
---|
1067 | this variable (one is already existing: MHTheta, which is now the
|
---|
1068 | default in ganymed). It is setup through ganymed.rc
|
---|
1069 |
|
---|
1070 | - added a full featured spectrum program (sponde) which reads
|
---|
1071 | ganymed output and monte carlos and compiles a spectrum
|
---|
1072 |
|
---|
1073 |
|
---|
1074 |
|
---|
1075 | *** Version 0.9.1 (2005/04/14)
|
---|
1076 |
|
---|
1077 | - Fix bug on the arrival time reconstruction when using Digital
|
---|
1078 | Filter (in some marginal cases (10%) times were reconstructed shifted
|
---|
1079 | by 0.2 slices)
|
---|
1080 |
|
---|
1081 | - all executables now return 2 where in previous versions -1 has
|
---|
1082 | been returned (gave problems with shell-scripts)
|
---|
1083 |
|
---|
1084 | - the Hi-/Lo-Gain intercalibration for monte carlo files is now
|
---|
1085 | also done with a intercalibration input file
|
---|
1086 |
|
---|
1087 | - a bug in the time fine adjustment of the digital filter has been fixed
|
---|
1088 |
|
---|
1089 | - a lot of small fixes to calling TPad::Divide with a margin==0
|
---|
1090 |
|
---|
1091 | - MStatusDisplay now shows the memory usage
|
---|
1092 |
|
---|
1093 | - added a memory leak statistic after the eventloop
|
---|
1094 |
|
---|
1095 | - MHadronness replaced by MParameterD
|
---|
1096 |
|
---|
1097 | - MEnergyEst replaced by MParameterD
|
---|
1098 |
|
---|
1099 | - wobble mode can now be switched on from the data-set
|
---|
1100 |
|
---|
1101 | - switched on bad pixel detection for a pedestal level
|
---|
1102 | which is more than 5 times the variance
|
---|
1103 |
|
---|
1104 | - Fixed default paths to be correct for the new data center
|
---|
1105 |
|
---|
1106 | - Fixed handling of drive data. The pointing position in now
|
---|
1107 | copied to MPointingPos inside star for real and MC events
|
---|
1108 |
|
---|
1109 | - made sure, that the sequences in a dataset are sorted by
|
---|
1110 | their number to ensure the correct synchronization
|
---|
1111 |
|
---|
1112 | - added all resource files necessary to handle spline extraction
|
---|
1113 | of signal for the late 2004 and the early 2005 data
|
---|
1114 |
|
---|
1115 | - update the reference lines for the december data
|
---|
1116 |
|
---|
1117 | - changed default for fgHiGainFirst from 2 to 0 in spline extractor
|
---|
1118 | This is important for the Dec. and Jan. data where the calibration
|
---|
1119 | pulse position changes much.
|
---|
1120 |
|
---|
1121 | - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
|
---|
1122 | filter. This corrects only an defective extraction of the MC at
|
---|
1123 | low-gain signals lower than 90 phes.
|
---|
1124 |
|
---|
1125 | - fixed some slowdown in calibrating data with interleaved events from
|
---|
1126 | Jan and Dec. As a workaround made the pretty palette the default.
|
---|
1127 | The inverse Deep Blue Sea has a bug which slows down long calibration
|
---|
1128 | runs a lot.
|
---|
1129 |
|
---|
1130 | - implemented new values from new starguider report as defined
|
---|
1131 | in TDAS00-07 V7.1 (eg SkyBrighness)
|
---|
1132 |
|
---|
1133 | - Fixed the formerly wrong unit of azimuth and zenith angle deviation
|
---|
1134 | in starguider report (If you merpp the same reports with this version
|
---|
1135 | you'll get the correct units (arcmin) but a different result
|
---|
1136 | than with old versions (wrong units))
|
---|
1137 |
|
---|
1138 | - Now the status display can also write PNG, JPEG and XPM (other file
|
---|
1139 | formats are still unsupported by root)
|
---|
1140 |
|
---|
1141 | - added a lot of scripts and macros in directory datacenter used
|
---|
1142 | for automatic processing
|
---|
1143 |
|
---|
1144 |
|
---|
1145 |
|
---|
1146 | *** Version 0.9 (2005/03/23)
|
---|
1147 |
|
---|
1148 | - Calibration is now done autmatically into photo-electrons like
|
---|
1149 | decided by the Collaboration Board
|
---|
1150 |
|
---|
1151 | - Reference lines in the display can be read from resource file
|
---|
1152 |
|
---|
1153 | - Interlaced calibration events can be handled by callisto
|
---|
1154 |
|
---|
1155 | - Hi-Gain vs. Lo-Gain calibration constants can be calculated
|
---|
1156 | and applied in callisto.
|
---|
1157 |
|
---|
1158 | - class MJCalibTest can be called by callisto
|
---|
1159 |
|
---|
1160 | - callisto can now run with three data types: rawdata, rootdata, MC
|
---|
1161 |
|
---|
1162 | - added two classes mreport/MReportStarguider.cc and
|
---|
1163 | mreport/MReportStarguider.h for implementing starguider-data
|
---|
1164 |
|
---|
1165 | - the output of merpp-update now contains starguider information:
|
---|
1166 | MReportStarguider and MTimeStarguider
|
---|
1167 |
|
---|
1168 | - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
|
---|
1169 | values were lower than they should. This was more visible for high
|
---|
1170 | energy (Size) events.
|
---|
1171 |
|
---|
1172 | - Made MExtractTimeAndChargeDigitalFilter the default for callisto
|
---|
1173 |
|
---|
1174 | - added a new loop to callisto to support the correct extraction of
|
---|
1175 | the pedestal and pedestal rms through the signal extractor
|
---|
1176 |
|
---|
1177 | - added class to perform fourier tranformation of a hexagonal structure
|
---|
1178 | (MHexagonalFT)
|
---|
1179 |
|
---|
1180 | - added class to perform fourier tranformation of a hexagonal structure
|
---|
1181 | in a tasklist (MHexagonalFTCalc) example: hft.C
|
---|
1182 |
|
---|
1183 | - added class to enhance the MCerPhotEvt from the Magic camera geometry
|
---|
1184 | MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
|
---|
1185 | small pixels, example: extendcam.C
|
---|
1186 |
|
---|
1187 | - added possibility to write data to memory (TTree) using MWriteRootFile
|
---|
1188 |
|
---|
1189 | - added possibility to read a TTree stored only in memory by MReadTree
|
---|
1190 |
|
---|
1191 | - new classes to deal with the interleaved calibration events:
|
---|
1192 | MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
|
---|
1193 |
|
---|
1194 | - implemented filters to callisto to skip calibration events
|
---|
1195 |
|
---|
1196 | - changed callisto to calculate three kinds of pedestals and pedestal rms:
|
---|
1197 | + fundamental pedestal (MPedPhotFundamental): extracted directly from
|
---|
1198 | the slices by statistics
|
---|
1199 | + pedestal from extractor (MPedPhotFromExtractor): extracted with the
|
---|
1200 | signal extractor without randomization
|
---|
1201 | + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
|
---|
1202 | with the signal extractor with randomization (extraction window is
|
---|
1203 | randomly fixed)
|
---|
1204 | The three kind of pedestal is not yet implemented (for speed reasons) as
|
---|
1205 | long as nobody really needs it:
|
---|
1206 | + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
|
---|
1207 | extracted with the signal extractor with randomization
|
---|
1208 |
|
---|
1209 | - callisto now finds the pulse position in the data automatically
|
---|
1210 |
|
---|
1211 | - implemented data reduction in calibrated data by reducing the precision
|
---|
1212 | of the stored floating point values (pedestal, rms and signal) to
|
---|
1213 | roughly 0.5%
|
---|
1214 |
|
---|
1215 | - fixed showplot to make file format conversion (eg. converting a
|
---|
1216 | status display stored in a root file into a postscript file) in
|
---|
1217 | batch mode possible:
|
---|
1218 | showplot -b --save-as-ps[=outfile.ps] infile.root
|
---|
1219 |
|
---|
1220 | - Allow class names as part of filter rules, eg
|
---|
1221 | (MFSupercuts) && (MHillas.fSize>100)
|
---|
1222 |
|
---|
1223 | - fixed a lot of stuff to allow all programs to process MonteCarlo
|
---|
1224 | camera files.
|
---|
1225 |
|
---|
1226 | - enhanced possibility to debug reading of resource file
|
---|
1227 |
|
---|
1228 | - MDataChain should handle priorities of operator more
|
---|
1229 | accurate now
|
---|
1230 |
|
---|
1231 | - completely revised the container in which the signal is stored
|
---|
1232 | MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
|
---|
1233 | * the new implementation is faster and
|
---|
1234 | * needs less storage space
|
---|
1235 |
|
---|
1236 | - FIRST version which can process Monte Carlos through the
|
---|
1237 | whole chain of programs (callisto, star, etc)
|
---|
1238 |
|
---|
1239 | - implemented new image parameters for the border length of
|
---|
1240 | the shower image (MNewImagePar2)
|
---|
1241 |
|
---|
1242 | - implemented wobble-mode in ganymed
|
---|
1243 |
|
---|
1244 | - new class (MJOptimize) taking care of all optimization processes
|
---|
1245 |
|
---|
1246 |
|
---|
1247 |
|
---|
1248 | *** Version 0.8.6 (2004/10/05)
|
---|
1249 |
|
---|
1250 | - New combined signal and time extractor
|
---|
1251 | MExtractTimeAndChargeDigitalFilter
|
---|
1252 |
|
---|
1253 | - The Report for the trigger section in the CC run summary has been
|
---|
1254 | updated, and now the IPRs (Individual Pixel Rates) are available.
|
---|
1255 |
|
---|
1256 | - new macros for database interaction: filldotrun.C, filldotrbk.C
|
---|
1257 |
|
---|
1258 | - added new program which can convert colored output which was redirected
|
---|
1259 | into a file back into colored text (for example to display it with
|
---|
1260 | more): showlog
|
---|
1261 |
|
---|
1262 | - added new program to display an MStatusArray of plots (stored with
|
---|
1263 | MStatusDisplay) from a file: showplot
|
---|
1264 |
|
---|
1265 | - Added support for Sequences (MSequence). Sequences are blocks of run
|
---|
1266 | files containing the same calibration and belonging to the same
|
---|
1267 | source
|
---|
1268 |
|
---|
1269 | - Added a new task (MTaskEnv) which can be used in setup files to switch
|
---|
1270 | between different tasks (for example to choose a signal extractor)
|
---|
1271 |
|
---|
1272 | - Implemented automatic file splitting in MWriteRootFile
|
---|
1273 |
|
---|
1274 | - After image cleaning an island index is assigned to all used pixels.
|
---|
1275 | The index corresponds to the order of the islands in size.
|
---|
1276 |
|
---|
1277 | - added a cleaning which takes signal height _and_ arrival time into
|
---|
1278 | account: probability cleaning (for more details see MImgCleanStd)
|
---|
1279 |
|
---|
1280 | - added a cleaning which takes takes the absolute number of photons
|
---|
1281 | times the area ratio as cleaning level
|
---|
1282 | (for more details see MImgCleanStd)
|
---|
1283 |
|
---|
1284 | - Changed calculation of image parameters such, that it can be done
|
---|
1285 | for all used pixels or the pixels with a defined island index only
|
---|
1286 |
|
---|
1287 | - implemented new image parameters displaying the number of islands,
|
---|
1288 | saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
|
---|
1289 |
|
---|
1290 | - event display in executable changed to support also calibrated files
|
---|
1291 | (done with MJCalibrateSignal)
|
---|
1292 |
|
---|
1293 | - added program doing the calibration and the signal extraction
|
---|
1294 | and signal calibration: callisto Most part of the setup is done
|
---|
1295 | by a resource file: callisto.rc
|
---|
1296 |
|
---|
1297 | - implemented support for pixels with negative IDs (Raw file format
|
---|
1298 | version 4)
|
---|
1299 |
|
---|
1300 | - implemented an new option in merpp (--auto-time) to get the time
|
---|
1301 | range for cc and/or caco data from the run header of the raw data
|
---|
1302 |
|
---|
1303 | - New star-program (star and MJStar). Taking calibrated data from
|
---|
1304 | callisto/MJCalibrateSignal as input. The setup is done through
|
---|
1305 | a resource file: star.rc
|
---|
1306 |
|
---|
1307 | - Added possibility to setup the eventloop in the mars-executable
|
---|
1308 | Camera Display by a resource file: mars.rc
|
---|
1309 |
|
---|
1310 | - The the mars-executable Camera Display can now also read
|
---|
1311 | calibrated data files written by callisto/MJCalibrateSignal
|
---|
1312 |
|
---|
1313 | - Added a new class which can calculate the source position in
|
---|
1314 | the camera from a pointing model known to be correct and
|
---|
1315 | the pointing model used for observations (MSrcPosFromModel)
|
---|
1316 |
|
---|
1317 | - added a new version of the class calculating the effective on-time
|
---|
1318 | MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
|
---|
1319 | MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
|
---|
1320 | MHTimeDiffTheta.
|
---|
1321 |
|
---|
1322 | - added the possibility to count how often a signal is above (or
|
---|
1323 | below) a certain threshold in MHCamEvent and MHCamEventRot (this
|
---|
1324 | can replace MHTriggerLvl0)
|
---|
1325 |
|
---|
1326 | - added ore convinient ways to set the axis-titles of your histograms
|
---|
1327 | in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
|
---|
1328 | MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
|
---|
1329 |
|
---|
1330 |
|
---|
1331 |
|
---|
1332 | *** Version 0.8.5 (2004/08/06)
|
---|
1333 |
|
---|
1334 | - new Signal Extractors: MExtractFixedWindowSpline
|
---|
1335 | and MExtractAmplitudeSpline
|
---|
1336 |
|
---|
1337 | - implementes interleave in merpp to be able to merpp parts of a file
|
---|
1338 |
|
---|
1339 | - implemented force-functionality to merpp
|
---|
1340 |
|
---|
1341 | - star display to display star catalogs (MAstroCatalog)
|
---|
1342 |
|
---|
1343 | - star display to 'mirror' stars to the camera (MAstroCamera)
|
---|
1344 |
|
---|
1345 | - implemented a new cleaning option which allows cleaning scaled with
|
---|
1346 | the real ratio of the rms depending on the pixel size, not only the
|
---|
1347 | square root of the pixelsize (MImgCleanStd, MCameraData)
|
---|
1348 |
|
---|
1349 | - removed obsolete MBlind* classes
|
---|
1350 |
|
---|
1351 | - Signal extractor taking the AB flag into account implemented (this makes
|
---|
1352 | an odd number of slices for signal extraction possible
|
---|
1353 | (MExtractSignalABcorr)
|
---|
1354 |
|
---|
1355 | - implemented a class extracting the pedestal from the raw-data (events)
|
---|
1356 | itself using empty lo-gain (MpedCalcFromLoGain)
|
---|
1357 |
|
---|
1358 | - Added mean values to MPedPhotCam
|
---|
1359 |
|
---|
1360 | - Added Makefile for Darwin (this OS is NOT officially supported!)
|
---|
1361 |
|
---|
1362 |
|
---|
1363 |
|
---|
1364 | *** Version 0.8.4 (2004/04/19)
|
---|
1365 |
|
---|
1366 | - new fast arrival time extractor using cubic splines:
|
---|
1367 | MExtractTimeFastSpline
|
---|
1368 |
|
---|
1369 | - implementes multi-argument support in MDataChain
|
---|
1370 | ("pow(a, b)")
|
---|
1371 |
|
---|
1372 | - implemented double reference support in MDataChain
|
---|
1373 | ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
|
---|
1374 |
|
---|
1375 | - added support in MF for expressiond like
|
---|
1376 | "MHillas.fWidth<2*<MHillas.fLength"
|
---|
1377 |
|
---|
1378 | - MDataChain is now able to support variables like [0], [1], ...
|
---|
1379 | which can be used in fit functions as parameters. The interface
|
---|
1380 | is implemented through the new virtual function
|
---|
1381 | MParContainer::SetVariables
|
---|
1382 |
|
---|
1383 | - added new class MArrivalTimeCam/MArrivalTimePix:
|
---|
1384 | Storage containers to hold the ArrivalTime of the camera/pixel
|
---|
1385 |
|
---|
1386 | - added new classes for the calibration of relative arrival times:
|
---|
1387 | MCalibrationRelTimePix and MCalibrationRelTimeCam
|
---|
1388 |
|
---|
1389 | - added new classes to extract the signal of the blind pixel and the
|
---|
1390 | PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
|
---|
1391 |
|
---|
1392 | - added new classes for the bad-pixels treatment (MBadPixels*)
|
---|
1393 | which are more powerfull than the old ones (MBlindPixel*)
|
---|
1394 | and will replace them.
|
---|
1395 |
|
---|
1396 | - added filter against cosmics: MFCosmics
|
---|
1397 |
|
---|
1398 | - added new class MArrivalTimeCalc2:
|
---|
1399 | Calculates the arrival time as the signal weighted mean of the time
|
---|
1400 | slices in the maximum window
|
---|
1401 |
|
---|
1402 | - added a new macro call pointspreadfucntion.C that fits with a 2D
|
---|
1403 | gaussian the DC spot for an star. It gives you the RMS of
|
---|
1404 | the PSF and the center of the star, very useful for misspointing
|
---|
1405 | studies.
|
---|
1406 |
|
---|
1407 | - added support for multi-telescope camera files. Added classes
|
---|
1408 | MStereoCalc and MStereoPar, classes to calculate and store shower
|
---|
1409 | parameters calculated from the data of two telescopes, for the MC
|
---|
1410 | studies regarding the MAGIC clone.
|
---|
1411 |
|
---|
1412 | - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
|
---|
1413 | MC data calibrated in photons instead of ADC counts.
|
---|
1414 |
|
---|
1415 | - added three macros to show the calibration and analysis chain of
|
---|
1416 | MC data. The macro starmc.C does both calibration and analysis, producing
|
---|
1417 | an output containing Hillas parameters for each event. The macro
|
---|
1418 | mccalibrate.C does just the calibration and writes out a file containing
|
---|
1419 | pixel information in photons instead of FADC data. The macro starmc2.C
|
---|
1420 | reads in such a file and produces an output with Hillas parameters.
|
---|
1421 |
|
---|
1422 | - added MPedPhotCalc to compute pedestals in units of photons, see
|
---|
1423 | macro pedphotcalc.C
|
---|
1424 |
|
---|
1425 | - added all class to perform the calibration, see macro calibration.C
|
---|
1426 |
|
---|
1427 | - added class MFFT to perform Fast Fourier Transforms
|
---|
1428 |
|
---|
1429 | - added class MSimulatedAnnealing to perform simulated annealing
|
---|
1430 | minimizations
|
---|
1431 |
|
---|
1432 | - added new macro bootcampstandardanalysis.C which holds the skeleton
|
---|
1433 | of the analysis chain discussed in the december bootcamp.
|
---|
1434 |
|
---|
1435 | - added support for DAQ raw data file format V2
|
---|
1436 |
|
---|
1437 | - implemented an arbitrary time stamp for the events from raw-data
|
---|
1438 | files with file version<3. It is calculated from the run number,
|
---|
1439 | the date of start and the FADC clock tick from the first module
|
---|
1440 |
|
---|
1441 | - implemented the correct decoding of the event time-stamp
|
---|
1442 | coming from the DAQ for raw-data files with file-version>2
|
---|
1443 |
|
---|
1444 | - added a new classes storing the pedestals in units of photons:
|
---|
1445 | MPedPhotPix, MPedPhotCam
|
---|
1446 |
|
---|
1447 | - added support for DC current files from the camera control
|
---|
1448 |
|
---|
1449 | - added support for start- and stop-time when merpping report files
|
---|
1450 |
|
---|
1451 | - added MReportCC storing the weather data from the CC-REPORT
|
---|
1452 |
|
---|
1453 | - added class to fill trainings and test matrices (MTFillMatrix)
|
---|
1454 |
|
---|
1455 | - added a filter performing a software trigger (MFSoftwareTrigger)
|
---|
1456 |
|
---|
1457 | - Added classes to perform parts of the standard analysis (Jobs):
|
---|
1458 | + MJPedestals
|
---|
1459 | + MJCalibration
|
---|
1460 | + MJExtractSignal
|
---|
1461 | Note: All of them are preliminary!
|
---|
1462 |
|
---|
1463 | - Added Iterator to iterate over files giving only the run-number
|
---|
1464 |
|
---|
1465 | - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
|
---|
1466 | the evolution of a sector vs time
|
---|
1467 |
|
---|
1468 |
|
---|
1469 |
|
---|
1470 | *** Version 0.8.3 (2003/12/05)
|
---|
1471 |
|
---|
1472 | - adapted Random Forest classes to allow the use with MC
|
---|
1473 | multi-telescope files which can be produced with the coming
|
---|
1474 | camera version 0.7.
|
---|
1475 |
|
---|
1476 | - added classes to read and interprete central control report files
|
---|
1477 | (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
|
---|
1478 |
|
---|
1479 | - enhanced merpp (the executable) to support .raw and .rep files.
|
---|
1480 |
|
---|
1481 | - added classes for light calibration (MCalibration* and
|
---|
1482 | MHCalibration*) by Markus Gaug. Further work has to be and will
|
---|
1483 | be done soon.
|
---|
1484 |
|
---|
1485 | - Added a preliminary 'synchronizer' (MReadReports) which will
|
---|
1486 | replace MReadMarsFile as soon as it is finished.
|
---|
1487 |
|
---|
1488 | - Added a tutorial macro demonstrating how report files are merpped
|
---|
1489 | and how they can be read from the root file in the correct order
|
---|
1490 | of time (readrep.C)
|
---|
1491 |
|
---|
1492 | - Added a generalized histogram (similar to MH3) called MVsTime
|
---|
1493 | which allows to plot variables (or rules - MDataChain - of
|
---|
1494 | variables) vs time. For an example have a look at tempvstime.C.
|
---|
1495 |
|
---|
1496 | - Changed the name of the event trees:
|
---|
1497 | + Events --> Events
|
---|
1498 | + PedEvents --> Pedestals
|
---|
1499 | + CalEvents --> Calibration
|
---|
1500 |
|
---|
1501 | - changed name of MTime in the event trees from MRawEvtTime to MTime
|
---|
1502 |
|
---|
1503 | - added displaying the sector indices to the mars event display
|
---|
1504 |
|
---|
1505 | - Magic Online Analysis (MOnA) implemented in a first version
|
---|
1506 | (see mona.cc, MOnlineDump and MOnlineDisplay)
|
---|
1507 |
|
---|
1508 | - added classes to calculate event rate
|
---|
1509 | (preliminary: MEventRateCalc, MEventRate)
|
---|
1510 |
|
---|
1511 | - added new executable 'readdaq' to read *.raw files from the DAQ directly
|
---|
1512 |
|
---|
1513 | - added classes dealing with the telescope pointing position (MPointing*)
|
---|
1514 |
|
---|
1515 | - implemented the 'final' Mars time stamp based on some experiences with
|
---|
1516 | the new 'Synchonizer'
|
---|
1517 |
|
---|
1518 |
|
---|
1519 |
|
---|
1520 | *** Version 0.8.2 (2003/11/10)
|
---|
1521 |
|
---|
1522 | - accelerated standard analysis by a factor of 6-8 ...
|
---|
1523 | + doing precalculations in MGeomCam for the pixel area ratio
|
---|
1524 | + creating a look up table for the single pixels in MCerPhotEvt
|
---|
1525 |
|
---|
1526 | - added task to calculates weights in case you want to 'change'
|
---|
1527 | the energy spectrum of a monte carlo file
|
---|
1528 | (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
|
---|
1529 |
|
---|
1530 | - added a new executable star which implements the
|
---|
1531 | star.C macro as precompiled executable. Currently a flexible
|
---|
1532 | setup is not possible, but a 'input card' setup will follow.
|
---|
1533 |
|
---|
1534 | - Starting to implement Multi-Telescope-Support based on the
|
---|
1535 | upcomming camera version 0.7. The base for a general support
|
---|
1536 | is implemented and the star-functionality is proven to work.
|
---|
1537 |
|
---|
1538 | - Replaced Event-Display in and Camera-Display in the Mars GUI
|
---|
1539 | executable by a more convinient display base on MStatusDisplay.
|
---|
1540 |
|
---|
1541 | - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
|
---|
1542 |
|
---|
1543 |
|
---|
1544 |
|
---|
1545 | *** Version 0.8.1 (2003/10/20)
|
---|
1546 |
|
---|
1547 | - added signal subtraction for pure on data by means of fitting
|
---|
1548 | the background in the off region or by performing a combined
|
---|
1549 | signal/background fit. Provides necessary histograms for
|
---|
1550 | obtaining energy spectra and a light curve.
|
---|
1551 |
|
---|
1552 | - added classes to perform and study the selection of the
|
---|
1553 | 2nd Level Trigger on MC data (example in triglvl2.C macro)
|
---|
1554 |
|
---|
1555 | - added pedestal calculation
|
---|
1556 |
|
---|
1557 | - implemented "democratic cleaning" (tail cut value proportional
|
---|
1558 | to pixel area) according to Wolfgang's suggestion.
|
---|
1559 |
|
---|
1560 | - added Sigmabar treatment (calculation and basic histogramming)
|
---|
1561 |
|
---|
1562 | - added basic routines to apply padding
|
---|
1563 |
|
---|
1564 | - added first implementation of MARS-based source visibility plotter
|
---|
1565 | (needs to be linked against slalib, preliminary version)
|
---|
1566 |
|
---|
1567 | - enhanced functionality of data chains: random numbers, conversion
|
---|
1568 | functions and access to MHMatrix objects
|
---|
1569 |
|
---|
1570 | - fixed some bugs in the CT1 Preproc file reader, which gave wrong
|
---|
1571 | numbers under certain circumstances (runs with 0 events included)
|
---|
1572 |
|
---|
1573 | - fixed a bug in the general filter MF (didn't work on some systems
|
---|
1574 | at all)
|
---|
1575 |
|
---|
1576 | - fixed a bug in chaining files, which caused the analysis to crash or
|
---|
1577 | ignore files
|
---|
1578 |
|
---|
1579 | - implemented more geometry classes describing the parameters used
|
---|
1580 | to simulate the PMT camera
|
---|
1581 |
|
---|
1582 | - added new Monte Carlo classes containing the setup of the different
|
---|
1583 | programs in the MC chain.
|
---|
1584 |
|
---|
1585 | - added a (preliminary) general task to evaluate chi-square of a given
|
---|
1586 | parameter in an eventloop.
|
---|
1587 |
|
---|
1588 | - first implementation of a container describing the observatory
|
---|
1589 | location (Long, Lat, etc)
|
---|
1590 |
|
---|
1591 | - added Random Forest - method for g/h-separation
|
---|
1592 |
|
---|
1593 | - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
|
---|
1594 | (this means, that it is compiling, but not yet fully tested)
|
---|
1595 |
|
---|
1596 | - added a new status display which can show the present status
|
---|
1597 | of histograms while an eventloop is running (MStatusDisplay,
|
---|
1598 | an example can be found at status.C)
|
---|
1599 |
|
---|
1600 | - reorganized directories:
|
---|
1601 | classes describing the image --> mimage
|
---|
1602 | classes containing Monte Carlo Histograms --> mhistmc
|
---|
1603 | classes for Random Forest method --> mranforest
|
---|
1604 |
|
---|
1605 | - added (event-)weights to fill histograms
|
---|
1606 |
|
---|
1607 | - colors in logging output to screen
|
---|
1608 |
|
---|
1609 | - changes to the Image Parameter declaration:
|
---|
1610 | + moved fConc, fConc1 from MHillasSrc to MNewImagePar
|
---|
1611 | + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
|
---|
1612 | + MHillasExt now derives from MParContainer instead of MHillas
|
---|
1613 | --> Files written with the old definition are more or less unreadable
|
---|
1614 |
|
---|
1615 | - reading of reflector files
|
---|
1616 |
|
---|
1617 | - display data from reflector files in the camera
|
---|
1618 |
|
---|
1619 | - implemented currents (and display them in the camera)
|
---|
1620 |
|
---|
1621 | - logarithmic scale in camera
|
---|
1622 |
|
---|
1623 | - added class to iterate through directory contents (MDirIter)
|
---|
1624 |
|
---|
1625 |
|
---|
1626 |
|
---|
1627 | *** Version 0.8 (2002/11/18)
|
---|
1628 |
|
---|
1629 | - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
|
---|
1630 |
|
---|
1631 | - corrected 48(!) wrong entries in the Next Neighbor table of the
|
---|
1632 | Magic Camera (all in the inner part of the outer ring, mostly
|
---|
1633 | missing a single NN)
|
---|
1634 |
|
---|
1635 | - Fixed a bug in the table describing the Next Neighbours of the
|
---|
1636 | CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
|
---|
1637 | have any neighbour)
|
---|
1638 |
|
---|
1639 | - changed trigrate.C: now it calculates the pure NSB triggers from
|
---|
1640 | a camera file (generated with no showers), so there is no need
|
---|
1641 | to introduce them by hand in the BgR array (for more details
|
---|
1642 | please ask Abelardo)
|
---|
1643 |
|
---|
1644 | - added MHHadronness (and MHadronness) as a general facility to evaluate
|
---|
1645 | the quality of a gamma-hadron seperation method
|
---|
1646 |
|
---|
1647 | - changed MWriteAsciiFile to accept rules (MDataChain)
|
---|
1648 |
|
---|
1649 | - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
|
---|
1650 | must be replaced by calles to MWriteAsciiFile::AddColumn and
|
---|
1651 | MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
|
---|
1652 | changed.
|
---|
1653 |
|
---|
1654 | - Implemented generalized event-matrices (one row per event)
|
---|
1655 | (MHMatrix)
|
---|
1656 |
|
---|
1657 | - implemented the one dimensional composite probabilities
|
---|
1658 | (MHCompProb, MCompProbCalc, comprob.C)
|
---|
1659 |
|
---|
1660 | - implemented the Multidimensional Distances (Next Neighbours, Kernel)
|
---|
1661 | (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
|
---|
1662 |
|
---|
1663 | - Added a camera display displaying the pixel numbers to the
|
---|
1664 | event display gui.
|
---|
1665 |
|
---|
1666 | - Added Monte Carlo Informations to event display gui
|
---|
1667 |
|
---|
1668 | - Changed the camera display to display the pixel numbering
|
---|
1669 |
|
---|
1670 | - Added three buttons to the camera display to change the palette
|
---|
1671 |
|
---|
1672 | - Added the number of used and core pixels after image cleaning
|
---|
1673 | to MHillas
|
---|
1674 |
|
---|
1675 | - Changed the algorithm used in MHillas according to TDAS 02-03
|
---|
1676 |
|
---|
1677 | - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
|
---|
1678 |
|
---|
1679 | - Changed the algorithm used in MHillasSrc according to TDAS 02-03
|
---|
1680 |
|
---|
1681 | - Added fCosDeltaAlpha to MHillasSrc
|
---|
1682 |
|
---|
1683 | - The numbers of photons used to calculate fConc and fConc1 in
|
---|
1684 | MHillasExt are now scaled with the pixel size, so that one get
|
---|
1685 | a four times smaller value for the bigger pixels in the outer ring.
|
---|
1686 |
|
---|
1687 | - added new task to smooth the camera contents (MCameraSmooth)
|
---|
1688 |
|
---|
1689 | - added possibility to use interpolated pixel values for blind pixels
|
---|
1690 | instead of removing it completely from the analysis
|
---|
1691 |
|
---|
1692 | - Implemented the possibility to save the whole eventloop with
|
---|
1693 | its setup to a file. This information can be read and from
|
---|
1694 | it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
|
---|
1695 | and MEvtLoop::MakeMacro. If you find something not working, please
|
---|
1696 | report - this stuff is still in a beta phase.
|
---|
1697 |
|
---|
1698 | - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
|
---|
1699 | file having crab starfield, but also for all following files - fixed
|
---|
1700 |
|
---|
1701 | - MTaskList::PrintStatistics can now be instructud to print also the
|
---|
1702 | title, too: use PrintStatistics(0, kTRUE)
|
---|
1703 |
|
---|
1704 | - Changed the image cleaning so that pixels with to many 'used'
|
---|
1705 | neighbors are left used (to get rid of 'holes' in events)
|
---|
1706 |
|
---|
1707 | - Introduced more output to the camera displays
|
---|
1708 |
|
---|
1709 | - Added an array of histograms (eg one hist per run), MHArray
|
---|
1710 |
|
---|
1711 | - Added a _preliminary_ version of the reader for CT1 PreProc files
|
---|
1712 | (MCT1ReadPreProc)
|
---|
1713 |
|
---|
1714 | - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
|
---|
1715 | (thanks to Raquel)
|
---|
1716 |
|
---|
1717 | - added the first energy estimator (MEnergyEstParam, estimate.C,
|
---|
1718 | estfit.C) using a parametrization
|
---|
1719 |
|
---|
1720 | - Added some new Monte Carlo paremeter containers used to store
|
---|
1721 | setup information from the MC chain (MMcConfigRunHeader,
|
---|
1722 | MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
|
---|
1723 |
|
---|
1724 |
|
---|
1725 |
|
---|
1726 | *** Version 0.7 (2002/04/30)
|
---|
1727 |
|
---|
1728 | - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
|
---|
1729 | the pedestal mean value was saved incorrectly. For files from
|
---|
1730 | this versions we substract 0.5 from the pedestal mean.
|
---|
1731 | WARNING: This may effect your results, so don't wonder...
|
---|
1732 |
|
---|
1733 | - First implementation of an algorithm using only triggered events
|
---|
1734 | for the collection area calculation
|
---|
1735 |
|
---|
1736 | - Ascii Output can now also be used for parameter containers which
|
---|
1737 | doesn't overload MParCointainer::AsciiWrite
|
---|
1738 |
|
---|
1739 | - The Ascii Output is now also capable of writing single data members
|
---|
1740 | of one container
|
---|
1741 |
|
---|
1742 | - You are now able to change the order of the values written to the
|
---|
1743 | ascii file
|
---|
1744 |
|
---|
1745 | - You can now specify a conversion factor for each data member written
|
---|
1746 | to an ascii file. This may be usefull to change the units of the
|
---|
1747 | data member (eg. degrees instead of millimeters in case of the
|
---|
1748 | hillas parameters)
|
---|
1749 |
|
---|
1750 | - Replaced old MHillas by a new structure which allows you to extend
|
---|
1751 | the parameters stored in MHillas very easily:
|
---|
1752 | see MHillas and MHillasExt
|
---|
1753 |
|
---|
1754 | - Added classes to handle source dependancy of image parameters:
|
---|
1755 | see MHillasSrc
|
---|
1756 |
|
---|
1757 | - Added container (MBinning) to have a standard input for the binning
|
---|
1758 | in different histograms (eg. the Energy bins should be the same in
|
---|
1759 | all histograms)
|
---|
1760 |
|
---|
1761 | - Changed Hillas histograms from mm to deg
|
---|
1762 |
|
---|
1763 | - Added the flexible binning to the hillas histograms
|
---|
1764 |
|
---|
1765 | - Added a filter for the alpha parameter (MFAlpha)
|
---|
1766 |
|
---|
1767 | - It is now possible to write single data members of a class object to
|
---|
1768 | an output stream instead of the whole container only
|
---|
1769 |
|
---|
1770 | - Added a generalized filter for a data member:
|
---|
1771 | MFDataMember filter("MHillas.fWidth", '<', 0.5);
|
---|
1772 |
|
---|
1773 | - Added a generalized Filter parser for more difficult filter rules
|
---|
1774 | MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
|
---|
1775 |
|
---|
1776 | - Added new Monte Carlo histograms:
|
---|
1777 | MHMcEnergyImpact and MHMcEfficiency
|
---|
1778 |
|
---|
1779 | - Added many new histograms needed for the flux calculation.
|
---|
1780 |
|
---|
1781 | - Added a generalized histograms which can fill and show up to three
|
---|
1782 | data members in either a one-, two- or three-dimensional histogram, eg:
|
---|
1783 | MH3 mh3("MHillas.fWidth", "MHillas.fLength");
|
---|
1784 |
|
---|
1785 | - Added:
|
---|
1786 | * calculation of <Theta> as a function of Theta (MHThetabarTheta)
|
---|
1787 | * calculation of <Theta> as a function of time (MHThetabarTime)
|
---|
1788 | they are needed in the flux calculation in
|
---|
1789 | order to select for a given bin in Theta (or time) the appropriate
|
---|
1790 | effective collection area, which is assumed to be given as a function
|
---|
1791 | of Theta and the true energy
|
---|
1792 |
|
---|
1793 | - Added calculation of the migration matrix in the energy
|
---|
1794 | (MHMcEnergyMigration):
|
---|
1795 | the migration matrix describes the migration from the true (E_true)
|
---|
1796 | to the estimated energy (E_est); it is needed to determine the
|
---|
1797 | distribution of E_true from the measured distribution of E_est
|
---|
1798 | by unfolding
|
---|
1799 |
|
---|
1800 | - changed the color palette in the camera display to DeapSea.
|
---|
1801 |
|
---|
1802 |
|
---|
1803 |
|
---|
1804 | *** Version 0.6 (2002/01/15)
|
---|
1805 |
|
---|
1806 | - Introduce the option of disable pixels (MBlindPixels and
|
---|
1807 | MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
|
---|
1808 | able to deal with Star Field NSB.
|
---|
1809 |
|
---|
1810 | - Fixed a bug in the pedestals substraction
|
---|
1811 |
|
---|
1812 | - Introduced verbosity levels
|
---|
1813 |
|
---|
1814 | - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
|
---|
1815 |
|
---|
1816 | - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
|
---|
1817 | work correctly (thanks to Abelardo)
|
---|
1818 |
|
---|
1819 | - Introduced correct treatment of the diffuse Night Sky Background
|
---|
1820 | and NSB (MMcPedestalNSB)
|
---|
1821 |
|
---|
1822 | - Corrected treatment of the electronic noise (MMcPedestalCopy)
|
---|
1823 |
|
---|
1824 | - Introduced MMcRunHeaders which contains monte carlo run informations
|
---|
1825 |
|
---|
1826 | - Added a 'Print'-Task (MPrint) which calls the Print function
|
---|
1827 | of a parameter container for each event
|
---|
1828 |
|
---|
1829 | - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
|
---|
1830 |
|
---|
1831 | - changes to be more efficient with root 3.02/06
|
---|
1832 |
|
---|
1833 | - root 3.02/06 fixes:
|
---|
1834 | + the memory leak when reading MRawEvtData
|
---|
1835 | + loosing more time than necessary to update the progress bar
|
---|
1836 |
|
---|
1837 | - MWriteAsciiFile is now capable of writing more than one container
|
---|
1838 | in a line. For example: To be able to write Monte Carlo and
|
---|
1839 | Hillas values (energy and alpha) in one line.
|
---|
1840 |
|
---|
1841 |
|
---|
1842 |
|
---|
1843 | *** Version 0.5 (2001/11/06)
|
---|
1844 |
|
---|
1845 | - Added new GUI functionality (Analysis)
|
---|
1846 |
|
---|
1847 | - Added a camera display to be able to display events in the camera
|
---|
1848 | together with the calculated hillas ellipse
|
---|
1849 |
|
---|
1850 | - Added a 'Clone'-Task (MClone) which can clone a parameter container
|
---|
1851 | object at any state of the analysis, so that the output are several
|
---|
1852 | states
|
---|
1853 |
|
---|
1854 | - Fixed a bug in the collection area error calculation
|
---|
1855 | (Thanks to Ciro and Abelardo)
|
---|
1856 |
|
---|
1857 | - Fixed a bug which causes merpp to crash in some environments
|
---|
1858 |
|
---|
1859 | - Implemented auto enabling scheme for Branches to speed up reading
|
---|
1860 | a lot (see MReadTree and MTask)
|
---|
1861 |
|
---|
1862 | - Fixed a bug in the Histogram classes which caused histograms to
|
---|
1863 | be written to a file by MWriteRootFile without request
|
---|
1864 |
|
---|
1865 | - changed the object I/O from the old stylish root I/O to the new
|
---|
1866 | 'auto evolution scheme' This was done only for classes which are not
|
---|
1867 | yet used in Monte Carlo files, so that these files are still readable.
|
---|
1868 |
|
---|
1869 | - Added support for a progress bar in MEvtLoop and MReadTree
|
---|
1870 | (see the Analysis Window in Mars for an example)
|
---|
1871 |
|
---|
1872 | - Fixed a bug in the package creation which disturbed the conversion
|
---|
1873 | between a mars version unpacked from a tar file and the repository.
|
---|
1874 |
|
---|
1875 | - Changed the code to writer merpped (converted into root format)
|
---|
1876 | raw files, to get faster (around 10%)
|
---|
1877 |
|
---|
1878 |
|
---|
1879 |
|
---|
1880 | *** Version 0.4 (2001/09/20)
|
---|
1881 |
|
---|
1882 | - This release is made to compile on a root version >= 3.00
|
---|
1883 |
|
---|
1884 | - Fixed a bug which causes MReadTree to read the first file only
|
---|
1885 |
|
---|
1886 | - Added a task to compute the trigger rate (MMcTriggerRateCalc)
|
---|
1887 |
|
---|
1888 | - Added a task to write a container to an Ascii file (MWriteAsciiFile)
|
---|
1889 |
|
---|
1890 | - Added a task to write several container to a root file (MWriteRootFile)
|
---|
1891 |
|
---|
1892 | - Added calculation of the Enegry Threshold (MMcThresholdCalc)
|
---|
1893 |
|
---|
1894 | - Added calculation of the collection area (MMcCollectionAreaCalc)
|
---|
1895 |
|
---|
1896 | - fixed some bugs in the Hillas calculation
|
---|
1897 |
|
---|
1898 | - added filters to be able to control the task execution dependent on
|
---|
1899 | a parameter (for example: the number of level 1 triggers in a MC-file)
|
---|
1900 |
|
---|
1901 |
|
---|
1902 |
|
---|
1903 | *** Version 0.3 (2001/04/23)
|
---|
1904 |
|
---|
1905 | - Many demo macros added
|
---|
1906 |
|
---|
1907 | - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
|
---|
1908 |
|
---|
1909 | - Hillas Calculation added
|
---|
1910 |
|
---|
1911 | - Standard image cleaning available
|
---|
1912 |
|
---|
1913 | - MReadTree is now able to handle more than one file
|
---|
1914 | (Remark: of the same structure)
|
---|
1915 |
|
---|
1916 | - Now we are able to display events in a first version of the
|
---|
1917 | Camera event display. To do this we must run the macro
|
---|
1918 | "macros/readCT1.C" to read data from CT1.
|
---|
1919 |
|
---|
1920 |
|
---|
1921 |
|
---|
1922 | *** Version 0.2 (2001/01/24)
|
---|
1923 |
|
---|
1924 | - First Implementation of a Gui to read the raw data. Start the
|
---|
1925 | gui with the command mars.
|
---|
1926 |
|
---|
1927 |
|
---|
1928 |
|
---|
1929 | *** Version 0.1 (2000/12/20)
|
---|
1930 |
|
---|
1931 | - First official release 0.1
|
---|
1932 |
|
---|
1933 | - Changes:
|
---|
1934 |
|
---|
1935 | + changed calling style of MRawPixelIterator from do...while to
|
---|
1936 | while-loop
|
---|