source: tags/Mars-V0.9.6/NEWS@ 10058

Last change on this file since 10058 was 7746, checked in by tbretz, 19 years ago
*** empty log message ***
File size: 69.4 KB
Line 
1 -*-*- END -*-*-
2
3 *** Version 0.9.6 (2006/05/24)
4
5 - general: changed the binning of the azimuthal profile of the camera
6 such that it is aligned with the 60deg boundaries.
7
8 - merpp: better handling of problems with the TH, TD part of the
9 CC-REPORT for files older than 200507190 and 200412210
10 respectively
11
12 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
13
14 - merpp: implementd latest changes in starguider reports (sinc 9th May)
15
16 - callisto: if an arrival time is extracted outside the fadc range is
17 was set to the boundary before. Now a random number is assigned
18 instead to avoid unfortunate coincidences of arrival times just
19 by this arbitrary value.
20
21 - callisto: added a new option to callisto.rc which allows
22 to set the maximum arrival time difference allowed for the
23 badpixel algorithm to determin whether a pixels belongs to a shower:
24 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
25
26 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
27 to 0.9 as suggested by Stefan due to a recent study on the fraction
28 of pixels surviving the image cleaning
29
30 - callisto: switched off error in case of "pulse is too much to the left"
31
32 - callisto: The extraction window is not adapted anymore. This means that
33 the pulse is extracted from the full range. The draw-back is that the
34 background (pedestal) will become slightly higher. Switching on/off
35 the PulsePosCheck in the callisto.rc only effects filling the
36 histograms.
37 WARNING: If the pulse is too much to the left data is calibrated!
38 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
39 in the database to make sure that your data is valid!
40
41 - star: Show also the number of stars correlated correctly by the
42 starguider
43
44 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
45 than one off-source region in wobble-mode. To use it add the following to
46 your ganymed_wobble.rc:
47 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
48 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
49 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
50 + Cut1.ThetaCut: None
51 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
52
53 - ganymed: in the case the latest report is older than a default (currently
54 one minute) and the current report will be skip the starguider
55 correction and calibration will be reset. The maximum age can be
56 setup from ganymed.rc by (minutes):
57 MPointingDevCalc.MaxAge: 1.5
58
59 - ganymed: A first implementation showing all size-bins for the theta-sq
60 resp. alpha-plots in a single tab automatically
61
62
63
64 *** Version 0.9.5.1 (2006/05/05)
65
66 - general: Added a new option "zdiff" to the Makefile which runs
67 "cvs diff" as "make diff" would do, but with compression
68
69 - general: accelerated MTFillMatrix (used for eample in all training
70 and optimization macros) by skipping some obsolete calles in the
71 eventloop the first and second loop could be accelerated by ~20%
72
73 - general: Added a missing feature in the MFilterList class which
74 prevented MFEnergySlope from working correctly in trainenergy.C
75
76 - general: Accelerated the random forest training and usage a bit
77
78 - merpp: Adapted to new raw data file format version 6
79
80 - merpp: fixed a problem with reading the starguider reports
81 after 6.3.2006
82
83 - callisto: At some times six pixels had to be exchanged manually in the
84 data. If the pixels to be swaped are both not found, an error was raised
85 and calibration was stopped. Now it is assumed they are intentially not
86 mapped and the Error has been changed to a Warning.
87
88 - star: Added new image cleaning based on the arrival time of the shower.
89 The new cleaning can be accessed using the parameter "Time" instead of
90 the the old one (like "Absolute) in the star.rc-file.
91 Recommended parameters:
92 + MImgCleanStd.CleanLevel1: 8.2
93 + MImgCleanStd.CleanLevel2: 5
94 + MImgCleanStd.CleanRings: 2
95 + MImgCleanStd.KeepSinglePixels: No
96
97 - star: Simplified the calculation of the effective on time. By letting
98 the fit start in the third bin the result should become more stable.
99 The fit quality is now ignored for the theta-plot which is not used
100 in the analysis later. Still better pre-cut which, for example,
101 remove events triggered by car-light (rate changing on a short
102 time-scale) are missing.
103
104 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
105 for optimization (kWeakSource) which is suggested by the Berlin
106 people for weak sources.
107
108 - macros: plotdb.C:
109 + if no dataset and no time-interval is given only sequences with
110 an effective on-time above five minutes are plotted anymore
111 + added a new tab "RelTime" displaying the relative on-time
112 (effective on-time divided by the observation time)
113
114 - macros: optim*.C: by skipping some obsolete calles in the eventloop
115 the optimization became a lot faster
116
117 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
118 To display them just delete the pads displayed on top.
119
120 - ganymed: fixed a bug which could cause strange behaviour in wobble
121 mode if no starguider information was available due to an incorrect
122 initialization of the starguider calibration
123
124 - ganymed: The scale region in the False Source Plot (MHDisp) can now
125 be changed from within the plot. It can also be setup from the
126 resource file using:
127 + MHDisp.fScaleMin: 0.325
128 + MHDisp.fScaleMax: 0.475
129
130 - ganymed, showplot: Fixed a problem with the fit to the off-data
131 (HistOff) which could cause a time lag or an inifinite loop.
132 The bug did not effect the results at all.
133
134 - sponde: Added a new tab showing the effective collection area after
135 trigger (including the software trigger)
136
137 - sponde: MMcSpectrumWeight has a new option which allows to define
138 the scaling factor not by the integral of the events but at
139 a defined energy:
140 e.g. MMcSpectrumWeight.NormEnergy: 200
141
142 - MTFillMatrix, sponde: by skipping some obsolete calles in the
143 eventloops the loop could be accelerated by ~20%
144
145
146
147 *** Version 0.9.5 (2006/03/13)
148
149 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
150 and added the standard Disp-parametrization
151
152 - macros: added a new macro datacenter/macros/plotstat.C allowing
153 to plot statistics about the data processing
154
155 - macros: added a new macro to plot the muon correction coefficients
156 versus period (macros/plot/mucal.C)
157
158 - showplot: path inflation for ganymed files was broken
159
160 - callisto: Fixed an important bug. When the number of saturating pixels
161 were calculated the bad pixel information already available from the
162 calibration was ignored. This yields wrong values in case pixels
163 are broken and saturate all the time or randomly.
164
165 - callisto: Updated Muon calibration constants. Spline data now also uses
166 different values for different periods
167
168 - star: The time-evolution shown in the effective on-time plot now displays
169 the axis range (if there are no holes it should be similar to the
170 effective on-time)
171
172 - star: Added two new image parameters:
173 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
174 the three pixels next to the center of gravity and the size
175 + MNewImagePar.fConcCore: The ratio of the signals of all
176 pixels inside or touching the ellipse and the size
177
178 - ganymed: now stops in requested source isn't found in catalog file
179
180 - ganymed: Many improvements to the phi-plot in wobble mode:
181 + with a template the ideal background is displayed
182 + a possible camera inhomogeneity is taken into account
183 + the anti theta cut is better supported
184 + the phi cut is automatically calculated from the theta cut
185 See the examples in ganymed_wobble.rc for more details.
186
187 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
188 times the bin-width instead of the absolute energy
189
190 - ganymed: New cuts for on/off and wobble mode
191
192 - ganymed: The smearing of the False Source plot has been increased
193 to 0.06
194
195 - ganymed: The starguider calibration can now be changed from the
196 resource file.
197 See the examples in ganymed*.rc for more details.
198
199 - ganymed: added a new option for on-/off-observations
200 MJCut.RandomSourcePosition
201 If switched on the distribution of observation time of the source
202 position in the camera is calculated from the on-data and randomly
203 applied with this distrbution to the off-data.
204
205 - ganymed: by skipping some obsolete calles in the eventloop the
206 first and second loop could be accelerated by ~20%
207
208 - ganymed: The default in ganymed_onoff.rc is now to determin the source
209 position in the off-data randomly according to its distribution in the
210 on-data.
211
212
213
214 *** Version 0.9.4.3 (2006/02/13)
215
216 - general: Fixed a bug in most of the programs which prevented the
217 compile date in the startup message to be displayed
218
219 - general: Simplified program calls. The following abbreviations
220 are now possible:
221 showlog callisto 55599
222 showplot signal 55599
223 star 55599
224 callisto 55999
225 ganymed 2
226 In this cases the corrsponding root-, log-, sequence- or dataset-
227 filename is automatically compiled using the default datacenter
228 paths ("/magic/*")
229
230 - general: Fixed a long outstanding bug which made axis tick marks
231 disappear if MDataFormula was used (eg. abs(x))
232
233 - general: Updated MMath with new functions to calculate the results of
234 a exponential, logarithmic and powerlaw fits analytically.
235
236 - general: Updated some macros with comments:
237 + macros/optim/optimdisp.C
238 + macros/optim/optimenergy.C
239 + macros/optim/optimwobble.C:
240
241 - general: MTFillMatrix (the class to fill one or two MHMatrix from
242 files) now allows adding a pre-cut like in the optimization. E.g. this
243 is useful to perform g/h-separation cuts before training the random
244 forest.
245
246 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
247 correctly assigned in the raw data assignement table. A fix to correct
248 the assignment tabel have been implemented.
249
250 - general: MAstroCatalog now allows rotating of the sky-grid and stars
251 by 90, 180 and 270 deg.
252
253 - general: the macro plotdb.C now allows to highlight sequences belonging
254 to a datset. For more details see the descritions in the macro.
255
256 - StatusDisplay: Fixed the algorithm to calculate the size ratio
257 of the display, it gave wrong results espacially for big sizes.
258 Now the embedded canvas should always have a ratio width/height=3/2.
259 The "Size" options have been updated with values fitting the 3/2
260 size ratio.
261
262 - RanForest:
263 + Updated the random forest classes to support also the
264 regression method implemented by Thomas H.
265 + added new tutorial macro how to train the random forest
266 for energy estimation (macros/optim/rfenergyest.C)
267 + new classes to train the random forest (still in development)
268 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
269 + new tutorial macros for random forest training in macros/train
270 trainenergy.C, traindisp.C, trainseparation.C
271
272 - mars: now allows to setup a cut in the resource file mars.rc to choose
273 the events to be displayed, eg:
274 Cut.Condition: {0} && {1}
275 Cut.0: MHillas.fSize>100
276 Cut.1: MHillas.fSize<900
277
278 - merpp: Made aware of the new .rep format 200510250. This includes
279 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
280 the discriminator thresholds (MCameraTD) and the disciminator
281 delays (MCameraTD). All of them come with the CC report and are therefor
282 written to the CC tree.
283
284 - callisto: fixed a bug in the calculation of the arrival times in
285 the Digital Filter. They were all shifted by the same amount
286 fHiGainFirst. This caused an offset in the order of the position of
287 the left border of the extraction window in the times calculated
288 from high-gain and from low-gain. The bug effected only the absolute
289 arrival times. The bug was there since 30.1.2005.
290
291 - callisto: Changed the ExtractionWindow for the pulse position check
292 such that the camera inhomogeneity becomes as less as possible and
293 comparable to the pulso position check switched off. More details
294 on the study will be given at our result web-page.
295
296 - ganymed: ganymed.rc, ganymed_onoff.rc:
297 changed to new cuts trained with 1ES1218 and Crab-data
298 for maximum sigma*log10(excess)
299
300 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
301 a new option was implemented to estimate Disp (CalcDisp)
302
303 - ganymed: Implemented two new options which allow
304 to overwrite the default path to search for the sequence files
305 --ins=/magic/sequences
306 and where to search for the image data
307 --ind=/magic/data/star
308
309 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
310 dx/dy from the resource file by
311 MSrcPosCorrect.Dx
312 MSrcPosCorrect.Dy
313
314 - ganymed: fixed reading the source catalog. Only as many chars
315 as the requested source name had were compared (If a source
316 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
317 were requested it could happen that the coordinates of
318 "1ES1218" were read) The source coordinates are now printed
319 in addition to its name to the logging output.
320
321 - ganymed: changed the background fit in the case of a ThetaSq function
322 from a polynomial to a exponential, this should give a big improvement
323 for on-only analysis'
324
325 - ganymed/sponde: Calculation of the error of single size-/energy-
326 bins now uses Li/Ma (5) instead of LiMa (17)
327
328 - sponde: Added a plot E^2*dN/dE
329
330 - sponde: The energy estimator plot should now show values like
331 they are commonly used.
332
333 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
334 (a powerlaw with cutoff didn't work before)
335
336
337
338 *** Version 0.9.4.2 (2005/10/01)
339
340 - general: added new tutorial macro macros/tutorials/threshold.C:
341 how to calculate the threshold
342
343 - general: added a new game. Start it from the interpreter with
344 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
345 and MagicReversi)
346
347 - general: neighbor pixels in MGeoms are now sorted clockwise
348
349 - merpp: made aware of new format 20050829-0
350
351 - callisto: New scale factors from muon analysis, stored in new
352 resource file resources/calibration.rc
353
354 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
355 the eventloop if something went wrong. This is necessary for the
356 automatic processing
357
358 - callisto: Implemented a new treatment for the time information
359 developed by S.Ruegamer, this should give much better response than
360 the old very primitive algorithm. This is especially important
361 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
362 treatment was buggy! As neighbor pixels to interpolate the
363 arrival times always the pixels 0 to 5 were taken)
364
365 - callisto: In addition to the new treatment of arrival times the
366 decision of the treatment whether a pixel contains shower
367 information or not is used to improve the signal interpolation
368 further. Previously interpolated pixels showed a non-zero signal
369 do the peak searching signal extractors. Having a signal pixel
370 beside raised the signal above the cleaning level. Thus the
371 pixel survived cleaning to often but with a too low mean signal.
372 By replacing empty pixels with a gaus (mean and rms from the
373 corresponding Area entries in MPedPhotCam) this effect can
374 be supressed.
375
376 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
377 got lost when the events were stored by the calibration... fixed.
378 (This was no problem for normal image cleaning because the pixel
379 content was artificially set to 0 not surviving standard cleaning
380 algorithm)
381
382 - callisto: Fixed a bug which caused the random and peak-search pedestal
383 extracted with an extractor to be exchanged for the first (roughly)
384 500 events (*Extractor and *ExtractorRndm).
385 (They were simply exchanged in callisto.cc) This bug might have been
386 introduced in Mars 0.9.4 when the order of calculation of the two
387 types of pedestal in callisto got exchanged. The bug only effects
388 the first seconds of data of each sequence.
389
390 - star: Taking the arrival time of Muons into account the calculation
391 of the parameters could be made independant of the noise
392 (pedestal rms). The dependance was due to the bias of the peak search
393 extractor. Now only a ZA dependamcy is left which is not yet fully
394 understood.
395
396 - ganymed: The sequences were still not sorted correctly in any case,
397 because they were sorted by the full qualified path name. Now they
398 are sorted by their sequence number.
399
400 - ganymed: new values for the spark-event-cut
401
402 - sponde: required missing MEnergyEst from ganymed.root... fixed.
403
404
405
406 *** Version 0.9.4.1 (2005/08/18)
407
408 - callisto: fixed some problems with the calibration in case of
409 inteleaved events. Therefor the final and some intermediate
410 fits are skipped which would take place on partly filled #
411 histograms and gave wrong results or failed completely.
412
413 - callisto: If the intermediate finalization of the histograms
414 calculating the mean charge of the calibration signal fails
415 it is counted now and printed in PostProcess of MCalibCalcFromPast.
416
417 - ganymed: Fixed some bugs which caused problems in On-only mode.
418 Still the false source plot doesn't give reasonable results.
419
420
421
422 *** Version 0.9.4 (2005/08/05)
423
424 - general: Fixed the ZA binning. It did not correctly fit the
425 MC binning
426
427 - general: Added a class to correct for the missfocussing in
428 April (MSrcPosCorrect)
429
430 - general: Random Forest energy estimator should now work properly
431
432 - general: MHCamera now displays the profiles in deg instead of mm
433
434 - general: MH::SetPalette offers a lot of new palettes
435
436 - general: MHillas - the case of CorrXY==0 is now handled properly
437
438 - general: implemented the possibility to change the line and
439 marker style of a sky-grid drawn by MAstroCatalog
440
441 - general: Runs in sequences and datasets are now automatically
442 ordered (it is assumed that the order of their filenames correctly
443 represents the order of observations) to ensure correct reading
444 of the subsystem data
445
446 - general: Runs cannot be added to a sequence twice anymore. Also
447 Sequences cannot be added twice anymore to a dataset.
448
449 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
450 It gave wrong results by 1./2pi
451
452 - showplot: got a new option to start a root interpreter, too
453
454 - mars: now displays a rough estimate of Disp and the third moment
455
456 - mars: now displays the event time MTime if available
457
458 - mars: show muon parameters graphically
459
460 - mars: now the file to open can be given as commandline
461 argument
462
463 - merpp: Added support for new arehucas version >= 200507190
464 implementing values for three temperature sensors in the
465 counting house (MCameraAUX) and the name of the HV settings file
466 (MCameraHV).
467
468 - merrp: Also fixed some problems with wrong versions numbers stated
469 by arehucas and implemented some fixed for old versions (<200407070)
470
471 - callisto: MCalibrationHiLoCam can now be printed from its context
472 menu, eg in the TBrowser
473
474 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
475 - 1.39 (MExtractTimeAndChargeSpline)
476 - 1.40 (MExtractTimeAndChargeDigitalFilter)
477 This is important mainly for timing studies.
478
479 - callisto: Changed limits in MHCalibrationChargeCalc from
480 - -100.125 to -98 (fgChargeHiGainFirst)
481 - 1899.875 to 1902. (fgChargeHiGainLast)
482 - -100.25 to -99 (fgChargeLoGainFirst)
483 - 899.75 to 901. (fgChargeLoGainLast)
484 Introduced new limits:
485 - fgNumLoGainBlackoutLimit: 0.05
486 - fgLoGainBlackoutLimit: 3.5
487 - fgLoGainPickupLimit: 3.5
488
489 - callisto: The handling of automatic weights for the digital filter
490 has been improved. There are now new calibration weights special
491 for Monte Carlo calibrations.
492
493 - callisto: Updated Muon scale with latest results (1% difference
494 for most data, 5% for Mar/Apr'05)
495
496 - callisto: use a new criterium to exclude bad pixels: If the high-gain
497 was saturated and the blackout-events in the low-gain exceed the
498 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
499 This excludes those pixels which have a saturating high-gain
500 channel, but the low-gain switch does not switch often enough
501 to make the distribution reliable.
502
503 - callisto: fix a bug counting the number of saturated events. Up to now,
504 the number of saturated slices was counted (which is one for a not too
505 high number), but for some (pathological) pixels, many more slices
506 saturated and produced wrong limits.
507
508 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
509 + MCalibrationRelTimeCam.CheckFitResults: Yes
510 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
511 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
512 + MCalibrationRelTimeCam.CheckOscillations: Yes
513
514 - callisto: introduce max. number of events for intercalibration,
515 the rest gets skipped. Default: 4096
516 The calibration causes too many un-reliable pixels if more
517 than about 5000 events are treated (@500 Hz) because of the
518 mode hopping of the VCSels. However, in the past, some
519 calibration runs have been taken (erroneously) with more
520 than 5000 events, especially the intensity scans where
521 a good precision is needed.
522
523 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
524 photo-electrons for the spline extractor by 1-2% (correctly).
525
526 - callisto: The intercalibration is now done using a full f-factor
527 method instead of a simple update. This makes things slower but
528 more reliable in terms of gain-fluctuations and sudden VCSEL gain
529 changes.
530
531 - callisto: MPedestalY3 now uses the same extraction range as the data
532 as calculated by MPedestalY2
533
534 - callisto: A check of the fraction of allowed unsuitable (10%) and
535 unreliable (30%) pixels has been addded when the conversion is
536 calculated from interleaved events
537
538 - star: fixed a bug which caused MEffectiveOnTime containers not to
539 be written. In the worst case they were skipped almost all, in the
540 best case they were all ok. It depends on how often the new value
541 was assigned just with an event which was skipped later by another
542 task
543
544 - star: new histograms MHPointing and MHRate
545
546 - star: New tab (Currents) displaying the time evolution of the mean
547 DC currents
548
549 - star: New tab (MeanRms) displaying the time volution of the mean
550 Pedestal Rms
551
552 - star: Output now contains MReportStarguider
553
554 - star: Improved muon analysis. Due to the absense of a constant
555 for the gaus fit for arc width and the fact that the arcwidth
556 plot was a histogram instead of a profile the resulting psf
557 became pedestal rms dependant
558
559 - ganymed: added new plot (MHPhi) for wobble mode as described in
560 http://www.astro.uni-wuerzburg.de/results/ringmethod/
561
562 - ganymed: corrects now (correctly?) for the misspointing in
563 May/April 05
564
565 - ganymed: Two new default templates for ganymed.rc are avilable:
566 ganymed_onoff.rc and ganymed_wobble.rc
567
568 - ganymed: The first version of MFMagicCuts has been released
569
570 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
571
572 - ganymed, sponde: There are two new options to determin the number
573 of bins for the signal region (NumBinsSignal) and the number of
574 total bins (NumBinsTotal) in the MHThetaSq histogram
575
576 - ganymed: optimized palettes for MHDisp
577
578 - ganymed: Fixed an important bug when using ThetaSq as fit function:
579 The result for the sigma of the gauss(sqrt(x)) fit was a factor
580 sqrt(2) to large
581
582 - ganymed: The false source plot (MHDisp) is now based on Disp
583 and a background model determined in the first loop is
584 subtracted
585
586 - ganymed: MFMagicCuts are now available in the cvs. The correct
587 solution for the disp ambiguity problem is now calculated using
588 the third moment. The third moment cut therefor is skipped.
589
590 - ganymed: Output now contains "Disp [MParameterD]" which sign is
591 already determined by the third moment along the major axis and
592 so its actual sign is aligned along the major axis of the shower.
593
594 - ganymed: If starguider data is available it is taken into account
595 when calculating the source position. This is especially important
596 for wobble data at high zenith angles and culmination data.
597
598 - ganymed: If available the starguider data is taken into account as
599 good as it is possible without a starguider calibration. To switch
600 it off add
601 MPointingDevCalc.MaxAbsDev: -1
602 to your ganymed.rc
603
604 - sponde: the zenith angle distribution is now weighted instead of
605 choosen by default. This gurantees higher statistics in the highest
606 and lowest energy bins. To switch this behaviour off use...
607
608 - sponde: now automatically displays the energy threshold
609
610
611
612 *** Version 0.9.3 (2005/06/03)
613
614 - general: MMcEvt now derived from MMcEvtBasic which should
615 have no influence on compatibility with older camera files
616
617 - general: Implemented a new option to MReadReports which allows
618 to force reading of the first event of some trees (eg. Drive-tree)
619 before any other tree.
620
621 - general: Made a fix to MPointingPosCalc which assumes that the
622 run-type is real-data if Process is called before ReInit, such
623 that also the very first Drive-events in a run are treated
624 correctly.
625
626 - shoplot now displays the filename in the title bar of the window
627
628 - merpp: new options: --auto-time-start --auto-time-stop which
629 allow to cut updating with slow-control at the start- or
630 (previousle --auto-time only allowed: and) stop-time of
631 the run stored in the runheader.
632
633 - callisto: changed default of fgFallTimeHiGain in
634 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
635 already set as default in callisto_Dec04Jan05.rc
636
637 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
638 now changes the filename for new weights automatically for
639 cosmics, MC and for different calibration colors.
640
641 - callisto: a problem with the order of some code cause the
642 name of the weights file in MPedestalY2 to be ignored.
643 Wrongly the calibration_UV weights were used instead
644 of the cosmics weights set in callisto.rc.
645
646 - callisto: should allow ct1 pulser data when the color is
647 explicitly set also for pretty new runs
648
649 - callisto: a new option (MCalibrateData.ScaleFactor) allows
650 to introduce an additional scale factor (should be around 1)
651 to adapt for slight deviations in different extractors from
652 the MC calibration. For MC calibrations the scale factor
653 is fixed to 1
654
655 - callisto: MFCosmics should handle very high signals a bit
656 more accurate now
657
658 - callisto: when calculating the mean pedestal rms for different
659 pixel sizes or sectors also kUnsuitableEvt is now taken into
660 account - not only kUnsuitableRun
661
662 - callisto: '-raw' option is now the default
663
664 - callisto: A dead pixel check has been implemented in MJPedestalC2.
665 This has the advantage that mean values in the calibration (eg
666 arrival times) are calculated more accuratly.
667
668 - callisto: In the resource file callisto_Dec04Jan05.rc
669 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
670
671 - callisto: new Hi-/Lo-Gain intercalibration constants
672 hilocalib_sp1.root and hilocalib_sp1_mc.root
673
674 - callisto: changed default for MJPedestalY2.MaxEvents
675 from 2000 to 5000 like in callisto_Dec04Jan05.txt
676
677 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
678 has changed from 9.0 to 6.0. This is necessary to exclude two very
679 ringing pixels in September which - when kept - destroy the image
680 cleaning around them (Markus G.)
681
682 - callisto: (!) The Muon analysis of all data taken so far has
683 suggested that different extractors give slightly different
684 absolute results after calibration, due to there different
685 handling of the calibration- and cosmics pulse shape. Although
686 the over all calibration seems to be a bit to pesimistic (or
687 the MC seems to be a little bit - 3-5% - too much attenuated).
688 There for correction factors have been introduced which correct
689 the calibration constants by
690 0.956937799 for Digital Filter (callisto.rc)
691 and
692 0.904159132 for Spline (callisto_Dec04Jan05.rc)
693 calibration. The main advantage is, that both data types can
694 be easily analysed together and compared to the same MC sample.
695 The factors are choosen such, that the reference is now a
696 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
697
698 - star: fixed a bug which caused the first bin of the histograms
699 vs time to disapear in PostProcess. This gave wrong results
700 on the screen. The output and all following programs not
701 directly accessing the histograms haven't been affected
702
703 - star, ganymed: Made sure that always the first Drive-tree event
704 is read and Processed before the first data event was read.
705
706 - ganymed: implemented the possibility to replace the standard
707 false source plot with a different one. For example: If
708 you want to use a Disp based FS plot use the resource:
709 NameHistFS: MHDisp
710 For details about the requirements of these plots look
711 at the corresponding classes
712
713 - MJOptimize: For On/Off and Wobble optimization MJOptimize
714 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
715 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
716 case MAlphaFitter is setup correctly. For On-Only optimization
717 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
718 RunOn() instead of Run(). For energy estimation MJOptimize
719 has been replaced by MJOptimizeEnergy
720
721 - sponde: The input MC spectrum can now be weighted to fake a
722 different spectrum. This is done via MMcSpectrumWeight. For
723 more details see the class description and sponde.rc
724
725 - sponde: The paremeter comparsion plots are not scaled by
726 their entries anymore. Instead the MC plot is scaled by using
727 the result spectrum of the analysis. If the input MC spectrum
728 and the result spectrum has different slopes the absolut
729 normalization is normally wrong.
730
731
732
733 *** Version 0.9.2 (2005/05/20)
734
735 - general: Changed the default paths for calibrated data and image
736 files. (The implemented access to these files doesn't yet exist)
737
738 - general: support for MRunIter has been removed from the job classes
739 (use the setter functions of MSeqeunce instead)
740
741 - general: ProcessFile has been renamed to Process in all job classes,
742 because ProcessFile is missleading
743
744 - general: The storage of the palette in MHCamera is now possible
745
746 - general: new bits describing unsuitable and unreliable pixels have
747 been introduced in MBadPixelsPix: kPreviouslyExcluded,
748 kDeadPedestalRms, kFluctuatingArrivalTimes
749
750 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
751 versions newer than V200404070
752
753 - general: support for cc file versions newer than V200504130. Added
754 support for active loads (MCameraActiveLoad) and central pixel
755 (MCameraCentralPixel)
756
757 - general: added new histograms for image parameters versus size
758 (MHVsSize)
759
760 - general: The eventloop now automatically calls PrintStatistics
761
762 - Status Display: Improved support for printing:
763 + A default can now be set in .rootrc (for more details see
764 MStatusDisplay::PrintPS)
765 + A print dialog is opened so that printer and command line
766 can be canged
767
768 - showlog: improved such that it handles different verbosity levels
769 more accurate now. This mean you can suppress output when
770 using showlog.
771
772 - showplot: improved
773 + The new graphics formats have been implemented
774 (pdf, svg, png, jpg and xpm)
775 + Implemented an interface for printing. Because you can change
776 the printing command from the command line you can use all
777 the nice postscript tool. To print a booklet for example call:
778 showplot -b --print --print-cmd="cat %f" filename.root | lpr
779 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
780 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
781
782 - callisto: fixed a bug in the recognition of the calibration bit
783 pattern. Concerns only intensity calibration. (The strength of the
784 intensity has been updated in some cases)
785
786 - callisto: add a filter against PIN Diode events when running over
787 calibration runs since some of the recent calibration runs have
788 been taken with Pin Diode.
789
790 - callisto: added support for the runs 39942, 39944, 44834, 39941,
791 39943, 44833 in the calibration (MCalibColorSet)
792
793 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
794 been set to 1e-18 in callisto_Dec04_Jan05.rc
795
796 - callisto: in callisto_Dec04Jan05.rc: set value for
797 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
798 statistics for the calculation of the mean pulse time
799 of the cosmisc
800
801 - callisto: the charge limit in the calibration has been raised
802 from 2.5 to 4.5
803
804 - callisto: new setup read from callisto.rc
805 + MCalibCalcFromPast.fNumEventsDump
806 + MHCalibrationChargeCam.NumHiGainSaturationLimit
807 + MHCalibrationChargeCam.NumLoGainSaturationLimit
808
809 - callisto: MExtractTimeAndChargeSpline extractor:
810 + The integration ranges were shifted by 0.2 FADC slices to the right.
811 + unreliable handling of floating point values caused different
812 results on different platform or with different compiler options:
813 The new algorithm is numerically exact and more accurate because
814 it doesn't calculate the integration position by multiple times
815 adding the step-size (which results in numerical uncertanties
816 exspecially if multiplied with large numbers)
817 + A lot of fixes have been introduced which effects integrating the
818 spline at the edges of the valid range. In this case any memory
819 was randomly accessed. This behaviour can be tested replacing
820 all MArrayF by TArrayF which perform a range check (but of course
821 they are a lot slower)
822 ! No result obtained with the Spline before can be trusted! Due to
823 random memory access it might by completely random!
824
825 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
826 + extraction range in the high gain to 4.
827 + weights file to cosmics_weights46.dat
828
829 - callisto:
830 + introduce the check for fluctuating arrival times.
831 + set charge limit to from 2.5 to 4.5
832 + introduce asymmetric exclusion due to "deviating number of phes":
833 Default: -9.0 +4.5
834 + make deviating number of phes unsuitable (see David's findings).
835
836 - callisto: fixed the display of unsuitable pixels. The old change
837 to a real profile in MHCamera broke it.
838
839 - callisto: The cosmics filter is used in MJCalibration now
840 independant of the pulser color (formaly it was used only for
841 CT1-pulser data). The threshold of number of max empty pixels
842 has been raised from 2% to 5% in MJCalibration. The maximum
843 fraction of rejected event is 50% otherwise the calibration has
844 failed. The filter now ignores unsuitable pixels.
845 Setup the filter from callisto.rc using "ContCosmics"
846 (see MFCosmics::ReadEnv)
847
848 - callisto: changed default for fgOffsetFromLogain back
849 from -2.8 to -1.8 in digital filter.
850
851 - callisto: for the common extractors
852 + MExtractFixedWindow
853 * MExtractTimeAndChargeSlidingWindow
854 * MExtractTimeAndChargeSpline
855 * MExtractTimeAndChargeDigitalFilter
856 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
857 and fResolutionPerPheLoGain
858
859 - callisto: Updated the hi-/lo-gain intercalibration constants
860 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
861 hilocalib_df6.root
862
863 - callisto: The default lo-gain extraction window for the
864 MExtractTimeAndChargeSlidingWindow extractor has been increased
865 from 6 to 8 to take the stretch of the pusle into account
866
867 - callisto (!!!): fixed an important bug in the setting of the
868 incoming pedestal pointer to the signal extractor extracting
869 pedestals. This bug caused the pedestals not to be subtracted
870 correctly in the calibration afterwards. The effect was about 10%
871 too high conversion factors for the digital filter and the spline
872 and more than 40% for the sliding window.
873 The bug existed since end of February! (Markus G.)
874
875 - star: added muon support to star. A new tab "MHMuonPar" is
876 displayed. The lower right plot is an estimate of the point spread
877 function. A reference value is displayed. To get the real PSF
878 you must compare with MC. The setup for the muon analysis
879 is done in star.rc. More informations can be found in
880 MHSingleMuon and MHCalibParCalc
881
882 - star: The weather data is now displayed in star
883
884 - star: MEventRateCalc handles the calculation of the event rate more
885 accurate now in case of the start of a new run inside a sequence
886
887 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
888 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
889 changed only minimally
890
891 - ganymed: (MJCut and MJOptimize) now displayes the number of
892 excess events versus size. The energy estimation is done in
893 MJSpectrum (sponde)
894
895 - ganymed: got support for using other variables than Alpha, eg. Theta.
896 Therefor you need a class deriving from MHAlpha which supports
897 this variable (one is already existing: MHTheta, which is now the
898 default in ganymed). It is setup through ganymed.rc
899
900 - added a full featured spectrum program (sponde) which reads
901 ganymed output and monte carlos and compiles a spectrum
902
903
904
905 *** Version 0.9.1 (2005/04/14)
906
907 - Fix bug on the arrival time reconstruction when using Digital
908 Filter (in some marginal cases (10%) times were reconstructed shifted
909 by 0.2 slices)
910
911 - all executables now return 2 where in previous versions -1 has
912 been returned (gave problems with shell-scripts)
913
914 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
915 also done with a intercalibration input file
916
917 - a bug in the time fine adjustment of the digital filter has been fixed
918
919 - a lot of small fixes to calling TPad::Divide with a margin==0
920
921 - MStatusDisplay now shows the memory usage
922
923 - added a memory leak statistic after the eventloop
924
925 - MHadronness replaced by MParameterD
926
927 - MEnergyEst replaced by MParameterD
928
929 - wobble mode can now be switched on from the data-set
930
931 - switched on bad pixel detection for a pedestal level
932 which is more than 5 times the variance
933
934 - Fixed default paths to be correct for the new data center
935
936 - Fixed handling of drive data. The pointing position in now
937 copied to MPointingPos inside star for real and MC events
938
939 - made sure, that the sequences in a dataset are sorted by
940 their number to ensure the correct synchronization
941
942 - added all resource files necessary to handle spline extraction
943 of signal for the late 2004 and the early 2005 data
944
945 - update the reference lines for the december data
946
947 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
948 This is important for the Dec. and Jan. data where the calibration
949 pulse position changes much.
950
951 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
952 filter. This corrects only an defective extraction of the MC at
953 low-gain signals lower than 90 phes.
954
955 - fixed some slowdown in calibrating data with interleaved events from
956 Jan and Dec. As a workaround made the pretty palette the default.
957 The inverse Deep Blue Sea has a bug which slows down long calibration
958 runs a lot.
959
960 - implemented new values from new starguider report as defined
961 in TDAS00-07 V7.1 (eg SkyBrighness)
962
963 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
964 in starguider report (If you merpp the same reports with this version
965 you'll get the correct units (arcmin) but a different result
966 than with old versions (wrong units))
967
968 - Now the status display can also write PNG, JPEG and XPM (other file
969 formats are still unsupported by root)
970
971 - added a lot of scripts and macros in directory datacenter used
972 for automatic processing
973
974
975
976 *** Version 0.9 (2005/03/23)
977
978 - Calibration is now done autmatically into photo-electrons like
979 decided by the Collaboration Board
980
981 - Reference lines in the display can be read from resource file
982
983 - Interlaced calibration events can be handled by callisto
984
985 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
986 and applied in callisto.
987
988 - class MJCalibTest can be called by callisto
989
990 - callisto can now run with three data types: rawdata, rootdata, MC
991
992 - added two classes mreport/MReportStarguider.cc and
993 mreport/MReportStarguider.h for implementing starguider-data
994
995 - the output of merpp-update now contains starguider information:
996 MReportStarguider and MTimeStarguider
997
998 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
999 values were lower than they should. This was more visible for high
1000 energy (Size) events.
1001
1002 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1003
1004 - added a new loop to callisto to support the correct extraction of
1005 the pedestal and pedestal rms through the signal extractor
1006
1007 - added class to perform fourier tranformation of a hexagonal structure
1008 (MHexagonalFT)
1009
1010 - added class to perform fourier tranformation of a hexagonal structure
1011 in a tasklist (MHexagonalFTCalc) example: hft.C
1012
1013 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1014 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1015 small pixels, example: extendcam.C
1016
1017 - added possibility to write data to memory (TTree) using MWriteRootFile
1018
1019 - added possibility to read a TTree stored only in memory by MReadTree
1020
1021 - new classes to deal with the interleaved calibration events:
1022 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1023
1024 - implemented filters to callisto to skip calibration events
1025
1026 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1027 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1028 the slices by statistics
1029 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1030 signal extractor without randomization
1031 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1032 with the signal extractor with randomization (extraction window is
1033 randomly fixed)
1034 The three kind of pedestal is not yet implemented (for speed reasons) as
1035 long as nobody really needs it:
1036 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1037 extracted with the signal extractor with randomization
1038
1039 - callisto now finds the pulse position in the data automatically
1040
1041 - implemented data reduction in calibrated data by reducing the precision
1042 of the stored floating point values (pedestal, rms and signal) to
1043 roughly 0.5%
1044
1045 - fixed showplot to make file format conversion (eg. converting a
1046 status display stored in a root file into a postscript file) in
1047 batch mode possible:
1048 showplot -b --save-as-ps[=outfile.ps] infile.root
1049
1050 - Allow class names as part of filter rules, eg
1051 (MFSupercuts) && (MHillas.fSize>100)
1052
1053 - fixed a lot of stuff to allow all programs to process MonteCarlo
1054 camera files.
1055
1056 - enhanced possibility to debug reading of resource file
1057
1058 - MDataChain should handle priorities of operator more
1059 accurate now
1060
1061 - completely revised the container in which the signal is stored
1062 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1063 * the new implementation is faster and
1064 * needs less storage space
1065
1066 - FIRST version which can process Monte Carlos through the
1067 whole chain of programs (callisto, star, etc)
1068
1069 - implemented new image parameters for the border length of
1070 the shower image (MNewImagePar2)
1071
1072 - implemented wobble-mode in ganymed
1073
1074 - new class (MJOptimize) taking care of all optimization processes
1075
1076
1077
1078 *** Version 0.8.6 (2004/10/05)
1079
1080 - New combined signal and time extractor
1081 MExtractTimeAndChargeDigitalFilter
1082
1083 - The Report for the trigger section in the CC run summary has been
1084 updated, and now the IPRs (Individual Pixel Rates) are available.
1085
1086 - new macros for database interaction: filldotrun.C, filldotrbk.C
1087
1088 - added new program which can convert colored output which was redirected
1089 into a file back into colored text (for example to display it with
1090 more): showlog
1091
1092 - added new program to display an MStatusArray of plots (stored with
1093 MStatusDisplay) from a file: showplot
1094
1095 - Added support for Sequences (MSequence). Sequences are blocks of run
1096 files containing the same calibration and belonging to the same
1097 source
1098
1099 - Added a new task (MTaskEnv) which can be used in setup files to switch
1100 between different tasks (for example to choose a signal extractor)
1101
1102 - Implemented automatic file splitting in MWriteRootFile
1103
1104 - After image cleaning an island index is assigned to all used pixels.
1105 The index corresponds to the order of the islands in size.
1106
1107 - added a cleaning which takes signal height _and_ arrival time into
1108 account: probability cleaning (for more details see MImgCleanStd)
1109
1110 - added a cleaning which takes takes the absolute number of photons
1111 times the area ratio as cleaning level
1112 (for more details see MImgCleanStd)
1113
1114 - Changed calculation of image parameters such, that it can be done
1115 for all used pixels or the pixels with a defined island index only
1116
1117 - implemented new image parameters displaying the number of islands,
1118 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1119
1120 - event display in executable changed to support also calibrated files
1121 (done with MJCalibrateSignal)
1122
1123 - added program doing the calibration and the signal extraction
1124 and signal calibration: callisto Most part of the setup is done
1125 by a resource file: callisto.rc
1126
1127 - implemented support for pixels with negative IDs (Raw file format
1128 version 4)
1129
1130 - implemented an new option in merpp (--auto-time) to get the time
1131 range for cc and/or caco data from the run header of the raw data
1132
1133 - New star-program (star and MJStar). Taking calibrated data from
1134 callisto/MJCalibrateSignal as input. The setup is done through
1135 a resource file: star.rc
1136
1137 - Added possibility to setup the eventloop in the mars-executable
1138 Camera Display by a resource file: mars.rc
1139
1140 - The the mars-executable Camera Display can now also read
1141 calibrated data files written by callisto/MJCalibrateSignal
1142
1143 - Added a new class which can calculate the source position in
1144 the camera from a pointing model known to be correct and
1145 the pointing model used for observations (MSrcPosFromModel)
1146
1147 - added a new version of the class calculating the effective on-time
1148 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1149 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1150 MHTimeDiffTheta.
1151
1152 - added the possibility to count how often a signal is above (or
1153 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1154 can replace MHTriggerLvl0)
1155
1156 - added ore convinient ways to set the axis-titles of your histograms
1157 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1158 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1159
1160
1161
1162 *** Version 0.8.5 (2004/08/06)
1163
1164 - new Signal Extractors: MExtractFixedWindowSpline
1165 and MExtractAmplitudeSpline
1166
1167 - implementes interleave in merpp to be able to merpp parts of a file
1168
1169 - implemented force-functionality to merpp
1170
1171 - star display to display star catalogs (MAstroCatalog)
1172
1173 - star display to 'mirror' stars to the camera (MAstroCamera)
1174
1175 - implemented a new cleaning option which allows cleaning scaled with
1176 the real ratio of the rms depending on the pixel size, not only the
1177 square root of the pixelsize (MImgCleanStd, MCameraData)
1178
1179 - removed obsolete MBlind* classes
1180
1181 - Signal extractor taking the AB flag into account implemented (this makes
1182 an odd number of slices for signal extraction possible
1183 (MExtractSignalABcorr)
1184
1185 - implemented a class extracting the pedestal from the raw-data (events)
1186 itself using empty lo-gain (MpedCalcFromLoGain)
1187
1188 - Added mean values to MPedPhotCam
1189
1190 - Added Makefile for Darwin (this OS is NOT officially supported!)
1191
1192
1193
1194 *** Version 0.8.4 (2004/04/19)
1195
1196 - new fast arrival time extractor using cubic splines:
1197 MExtractTimeFastSpline
1198
1199 - implementes multi-argument support in MDataChain
1200 ("pow(a, b)")
1201
1202 - implemented double reference support in MDataChain
1203 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1204
1205 - added support in MF for expressiond like
1206 "MHillas.fWidth<2*<MHillas.fLength"
1207
1208 - MDataChain is now able to support variables like [0], [1], ...
1209 which can be used in fit functions as parameters. The interface
1210 is implemented through the new virtual function
1211 MParContainer::SetVariables
1212
1213 - added new class MArrivalTimeCam/MArrivalTimePix:
1214 Storage containers to hold the ArrivalTime of the camera/pixel
1215
1216 - added new classes for the calibration of relative arrival times:
1217 MCalibrationRelTimePix and MCalibrationRelTimeCam
1218
1219 - added new classes to extract the signal of the blind pixel and the
1220 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1221
1222 - added new classes for the bad-pixels treatment (MBadPixels*)
1223 which are more powerfull than the old ones (MBlindPixel*)
1224 and will replace them.
1225
1226 - added filter against cosmics: MFCosmics
1227
1228 - added new class MArrivalTimeCalc2:
1229 Calculates the arrival time as the signal weighted mean of the time
1230 slices in the maximum window
1231
1232 - added a new macro call pointspreadfucntion.C that fits with a 2D
1233 gaussian the DC spot for an star. It gives you the RMS of
1234 the PSF and the center of the star, very useful for misspointing
1235 studies.
1236
1237 - added support for multi-telescope camera files. Added classes
1238 MStereoCalc and MStereoPar, classes to calculate and store shower
1239 parameters calculated from the data of two telescopes, for the MC
1240 studies regarding the MAGIC clone.
1241
1242 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1243 MC data calibrated in photons instead of ADC counts.
1244
1245 - added three macros to show the calibration and analysis chain of
1246 MC data. The macro starmc.C does both calibration and analysis, producing
1247 an output containing Hillas parameters for each event. The macro
1248 mccalibrate.C does just the calibration and writes out a file containing
1249 pixel information in photons instead of FADC data. The macro starmc2.C
1250 reads in such a file and produces an output with Hillas parameters.
1251
1252 - added MPedPhotCalc to compute pedestals in units of photons, see
1253 macro pedphotcalc.C
1254
1255 - added all class to perform the calibration, see macro calibration.C
1256
1257 - added class MFFT to perform Fast Fourier Transforms
1258
1259 - added class MSimulatedAnnealing to perform simulated annealing
1260 minimizations
1261
1262 - added new macro bootcampstandardanalysis.C which holds the skeleton
1263 of the analysis chain discussed in the december bootcamp.
1264
1265 - added support for DAQ raw data file format V2
1266
1267 - implemented an arbitrary time stamp for the events from raw-data
1268 files with file version<3. It is calculated from the run number,
1269 the date of start and the FADC clock tick from the first module
1270
1271 - implemented the correct decoding of the event time-stamp
1272 coming from the DAQ for raw-data files with file-version>2
1273
1274 - added a new classes storing the pedestals in units of photons:
1275 MPedPhotPix, MPedPhotCam
1276
1277 - added support for DC current files from the camera control
1278
1279 - added support for start- and stop-time when merpping report files
1280
1281 - added MReportCC storing the weather data from the CC-REPORT
1282
1283 - added class to fill trainings and test matrices (MTFillMatrix)
1284
1285 - added a filter performing a software trigger (MFSoftwareTrigger)
1286
1287 - Added classes to perform parts of the standard analysis (Jobs):
1288 + MJPedestals
1289 + MJCalibration
1290 + MJExtractSignal
1291 Note: All of them are preliminary!
1292
1293 - Added Iterator to iterate over files giving only the run-number
1294
1295 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1296 the evolution of a sector vs time
1297
1298
1299
1300 *** Version 0.8.3 (2003/12/05)
1301
1302 - adapted Random Forest classes to allow the use with MC
1303 multi-telescope files which can be produced with the coming
1304 camera version 0.7.
1305
1306 - added classes to read and interprete central control report files
1307 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1308
1309 - enhanced merpp (the executable) to support .raw and .rep files.
1310
1311 - added classes for light calibration (MCalibration* and
1312 MHCalibration*) by Markus Gaug. Further work has to be and will
1313 be done soon.
1314
1315 - Added a preliminary 'synchronizer' (MReadReports) which will
1316 replace MReadMarsFile as soon as it is finished.
1317
1318 - Added a tutorial macro demonstrating how report files are merpped
1319 and how they can be read from the root file in the correct order
1320 of time (readrep.C)
1321
1322 - Added a generalized histogram (similar to MH3) called MVsTime
1323 which allows to plot variables (or rules - MDataChain - of
1324 variables) vs time. For an example have a look at tempvstime.C.
1325
1326 - Changed the name of the event trees:
1327 + Events --> Events
1328 + PedEvents --> Pedestals
1329 + CalEvents --> Calibration
1330
1331 - changed name of MTime in the event trees from MRawEvtTime to MTime
1332
1333 - added displaying the sector indices to the mars event display
1334
1335 - Magic Online Analysis (MOnA) implemented in a first version
1336 (see mona.cc, MOnlineDump and MOnlineDisplay)
1337
1338 - added classes to calculate event rate
1339 (preliminary: MEventRateCalc, MEventRate)
1340
1341 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1342
1343 - added classes dealing with the telescope pointing position (MPointing*)
1344
1345 - implemented the 'final' Mars time stamp based on some experiences with
1346 the new 'Synchonizer'
1347
1348
1349
1350 *** Version 0.8.2 (2003/11/10)
1351
1352 - accelerated standard analysis by a factor of 6-8 ...
1353 + doing precalculations in MGeomCam for the pixel area ratio
1354 + creating a look up table for the single pixels in MCerPhotEvt
1355
1356 - added task to calculates weights in case you want to 'change'
1357 the energy spectrum of a monte carlo file
1358 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1359
1360 - added a new executable star which implements the
1361 star.C macro as precompiled executable. Currently a flexible
1362 setup is not possible, but a 'input card' setup will follow.
1363
1364 - Starting to implement Multi-Telescope-Support based on the
1365 upcomming camera version 0.7. The base for a general support
1366 is implemented and the star-functionality is proven to work.
1367
1368 - Replaced Event-Display in and Camera-Display in the Mars GUI
1369 executable by a more convinient display base on MStatusDisplay.
1370
1371 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1372
1373
1374
1375 *** Version 0.8.1 (2003/10/20)
1376
1377 - added signal subtraction for pure on data by means of fitting
1378 the background in the off region or by performing a combined
1379 signal/background fit. Provides necessary histograms for
1380 obtaining energy spectra and a light curve.
1381
1382 - added classes to perform and study the selection of the
1383 2nd Level Trigger on MC data (example in triglvl2.C macro)
1384
1385 - added pedestal calculation
1386
1387 - implemented "democratic cleaning" (tail cut value proportional
1388 to pixel area) according to Wolfgang's suggestion.
1389
1390 - added Sigmabar treatment (calculation and basic histogramming)
1391
1392 - added basic routines to apply padding
1393
1394 - added first implementation of MARS-based source visibility plotter
1395 (needs to be linked against slalib, preliminary version)
1396
1397 - enhanced functionality of data chains: random numbers, conversion
1398 functions and access to MHMatrix objects
1399
1400 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1401 numbers under certain circumstances (runs with 0 events included)
1402
1403 - fixed a bug in the general filter MF (didn't work on some systems
1404 at all)
1405
1406 - fixed a bug in chaining files, which caused the analysis to crash or
1407 ignore files
1408
1409 - implemented more geometry classes describing the parameters used
1410 to simulate the PMT camera
1411
1412 - added new Monte Carlo classes containing the setup of the different
1413 programs in the MC chain.
1414
1415 - added a (preliminary) general task to evaluate chi-square of a given
1416 parameter in an eventloop.
1417
1418 - first implementation of a container describing the observatory
1419 location (Long, Lat, etc)
1420
1421 - added Random Forest - method for g/h-separation
1422
1423 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1424 (this means, that it is compiling, but not yet fully tested)
1425
1426 - added a new status display which can show the present status
1427 of histograms while an eventloop is running (MStatusDisplay,
1428 an example can be found at status.C)
1429
1430 - reorganized directories:
1431 classes describing the image --> mimage
1432 classes containing Monte Carlo Histograms --> mhistmc
1433 classes for Random Forest method --> mranforest
1434
1435 - added (event-)weights to fill histograms
1436
1437 - colors in logging output to screen
1438
1439 - changes to the Image Parameter declaration:
1440 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1441 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1442 + MHillasExt now derives from MParContainer instead of MHillas
1443 --> Files written with the old definition are more or less unreadable
1444
1445 - reading of reflector files
1446
1447 - display data from reflector files in the camera
1448
1449 - implemented currents (and display them in the camera)
1450
1451 - logarithmic scale in camera
1452
1453 - added class to iterate through directory contents (MDirIter)
1454
1455
1456
1457 *** Version 0.8 (2002/11/18)
1458
1459 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1460
1461 - corrected 48(!) wrong entries in the Next Neighbor table of the
1462 Magic Camera (all in the inner part of the outer ring, mostly
1463 missing a single NN)
1464
1465 - Fixed a bug in the table describing the Next Neighbours of the
1466 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1467 have any neighbour)
1468
1469 - changed trigrate.C: now it calculates the pure NSB triggers from
1470 a camera file (generated with no showers), so there is no need
1471 to introduce them by hand in the BgR array (for more details
1472 please ask Abelardo)
1473
1474 - added MHHadronness (and MHadronness) as a general facility to evaluate
1475 the quality of a gamma-hadron seperation method
1476
1477 - changed MWriteAsciiFile to accept rules (MDataChain)
1478
1479 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1480 must be replaced by calles to MWriteAsciiFile::AddColumn and
1481 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1482 changed.
1483
1484 - Implemented generalized event-matrices (one row per event)
1485 (MHMatrix)
1486
1487 - implemented the one dimensional composite probabilities
1488 (MHCompProb, MCompProbCalc, comprob.C)
1489
1490 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1491 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1492
1493 - Added a camera display displaying the pixel numbers to the
1494 event display gui.
1495
1496 - Added Monte Carlo Informations to event display gui
1497
1498 - Changed the camera display to display the pixel numbering
1499
1500 - Added three buttons to the camera display to change the palette
1501
1502 - Added the number of used and core pixels after image cleaning
1503 to MHillas
1504
1505 - Changed the algorithm used in MHillas according to TDAS 02-03
1506
1507 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1508
1509 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1510
1511 - Added fCosDeltaAlpha to MHillasSrc
1512
1513 - The numbers of photons used to calculate fConc and fConc1 in
1514 MHillasExt are now scaled with the pixel size, so that one get
1515 a four times smaller value for the bigger pixels in the outer ring.
1516
1517 - added new task to smooth the camera contents (MCameraSmooth)
1518
1519 - added possibility to use interpolated pixel values for blind pixels
1520 instead of removing it completely from the analysis
1521
1522 - Implemented the possibility to save the whole eventloop with
1523 its setup to a file. This information can be read and from
1524 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1525 and MEvtLoop::MakeMacro. If you find something not working, please
1526 report - this stuff is still in a beta phase.
1527
1528 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1529 file having crab starfield, but also for all following files - fixed
1530
1531 - MTaskList::PrintStatistics can now be instructud to print also the
1532 title, too: use PrintStatistics(0, kTRUE)
1533
1534 - Changed the image cleaning so that pixels with to many 'used'
1535 neighbors are left used (to get rid of 'holes' in events)
1536
1537 - Introduced more output to the camera displays
1538
1539 - Added an array of histograms (eg one hist per run), MHArray
1540
1541 - Added a _preliminary_ version of the reader for CT1 PreProc files
1542 (MCT1ReadPreProc)
1543
1544 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1545 (thanks to Raquel)
1546
1547 - added the first energy estimator (MEnergyEstParam, estimate.C,
1548 estfit.C) using a parametrization
1549
1550 - Added some new Monte Carlo paremeter containers used to store
1551 setup information from the MC chain (MMcConfigRunHeader,
1552 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1553
1554
1555
1556 *** Version 0.7 (2002/04/30)
1557
1558 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1559 the pedestal mean value was saved incorrectly. For files from
1560 this versions we substract 0.5 from the pedestal mean.
1561 WARNING: This may effect your results, so don't wonder...
1562
1563 - First implementation of an algorithm using only triggered events
1564 for the collection area calculation
1565
1566 - Ascii Output can now also be used for parameter containers which
1567 doesn't overload MParCointainer::AsciiWrite
1568
1569 - The Ascii Output is now also capable of writing single data members
1570 of one container
1571
1572 - You are now able to change the order of the values written to the
1573 ascii file
1574
1575 - You can now specify a conversion factor for each data member written
1576 to an ascii file. This may be usefull to change the units of the
1577 data member (eg. degrees instead of millimeters in case of the
1578 hillas parameters)
1579
1580 - Replaced old MHillas by a new structure which allows you to extend
1581 the parameters stored in MHillas very easily:
1582 see MHillas and MHillasExt
1583
1584 - Added classes to handle source dependancy of image parameters:
1585 see MHillasSrc
1586
1587 - Added container (MBinning) to have a standard input for the binning
1588 in different histograms (eg. the Energy bins should be the same in
1589 all histograms)
1590
1591 - Changed Hillas histograms from mm to deg
1592
1593 - Added the flexible binning to the hillas histograms
1594
1595 - Added a filter for the alpha parameter (MFAlpha)
1596
1597 - It is now possible to write single data members of a class object to
1598 an output stream instead of the whole container only
1599
1600 - Added a generalized filter for a data member:
1601 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1602
1603 - Added a generalized Filter parser for more difficult filter rules
1604 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1605
1606 - Added new Monte Carlo histograms:
1607 MHMcEnergyImpact and MHMcEfficiency
1608
1609 - Added many new histograms needed for the flux calculation.
1610
1611 - Added a generalized histograms which can fill and show up to three
1612 data members in either a one-, two- or three-dimensional histogram, eg:
1613 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1614
1615 - Added:
1616 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1617 * calculation of <Theta> as a function of time (MHThetabarTime)
1618 they are needed in the flux calculation in
1619 order to select for a given bin in Theta (or time) the appropriate
1620 effective collection area, which is assumed to be given as a function
1621 of Theta and the true energy
1622
1623 - Added calculation of the migration matrix in the energy
1624 (MHMcEnergyMigration):
1625 the migration matrix describes the migration from the true (E_true)
1626 to the estimated energy (E_est); it is needed to determine the
1627 distribution of E_true from the measured distribution of E_est
1628 by unfolding
1629
1630 - changed the color palette in the camera display to DeapSea.
1631
1632
1633
1634 *** Version 0.6 (2002/01/15)
1635
1636 - Introduce the option of disable pixels (MBlindPixels and
1637 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1638 able to deal with Star Field NSB.
1639
1640 - Fixed a bug in the pedestals substraction
1641
1642 - Introduced verbosity levels
1643
1644 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1645
1646 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1647 work correctly (thanks to Abelardo)
1648
1649 - Introduced correct treatment of the diffuse Night Sky Background
1650 and NSB (MMcPedestalNSB)
1651
1652 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1653
1654 - Introduced MMcRunHeaders which contains monte carlo run informations
1655
1656 - Added a 'Print'-Task (MPrint) which calls the Print function
1657 of a parameter container for each event
1658
1659 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1660
1661 - changes to be more efficient with root 3.02/06
1662
1663 - root 3.02/06 fixes:
1664 + the memory leak when reading MRawEvtData
1665 + loosing more time than necessary to update the progress bar
1666
1667 - MWriteAsciiFile is now capable of writing more than one container
1668 in a line. For example: To be able to write Monte Carlo and
1669 Hillas values (energy and alpha) in one line.
1670
1671
1672
1673 *** Version 0.5 (2001/11/06)
1674
1675 - Added new GUI functionality (Analysis)
1676
1677 - Added a camera display to be able to display events in the camera
1678 together with the calculated hillas ellipse
1679
1680 - Added a 'Clone'-Task (MClone) which can clone a parameter container
1681 object at any state of the analysis, so that the output are several
1682 states
1683
1684 - Fixed a bug in the collection area error calculation
1685 (Thanks to Ciro and Abelardo)
1686
1687 - Fixed a bug which causes merpp to crash in some environments
1688
1689 - Implemented auto enabling scheme for Branches to speed up reading
1690 a lot (see MReadTree and MTask)
1691
1692 - Fixed a bug in the Histogram classes which caused histograms to
1693 be written to a file by MWriteRootFile without request
1694
1695 - changed the object I/O from the old stylish root I/O to the new
1696 'auto evolution scheme' This was done only for classes which are not
1697 yet used in Monte Carlo files, so that these files are still readable.
1698
1699 - Added support for a progress bar in MEvtLoop and MReadTree
1700 (see the Analysis Window in Mars for an example)
1701
1702 - Fixed a bug in the package creation which disturbed the conversion
1703 between a mars version unpacked from a tar file and the repository.
1704
1705 - Changed the code to writer merpped (converted into root format)
1706 raw files, to get faster (around 10%)
1707
1708
1709
1710 *** Version 0.4 (2001/09/20)
1711
1712 - This release is made to compile on a root version >= 3.00
1713
1714 - Fixed a bug which causes MReadTree to read the first file only
1715
1716 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
1717
1718 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
1719
1720 - Added a task to write several container to a root file (MWriteRootFile)
1721
1722 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
1723
1724 - Added calculation of the collection area (MMcCollectionAreaCalc)
1725
1726 - fixed some bugs in the Hillas calculation
1727
1728 - added filters to be able to control the task execution dependent on
1729 a parameter (for example: the number of level 1 triggers in a MC-file)
1730
1731
1732
1733 *** Version 0.3 (2001/04/23)
1734
1735 - Many demo macros added
1736
1737 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
1738
1739 - Hillas Calculation added
1740
1741 - Standard image cleaning available
1742
1743 - MReadTree is now able to handle more than one file
1744 (Remark: of the same structure)
1745
1746 - Now we are able to display events in a first version of the
1747 Camera event display. To do this we must run the macro
1748 "macros/readCT1.C" to read data from CT1.
1749
1750
1751
1752 *** Version 0.2 (2001/01/24)
1753
1754 - First Implementation of a Gui to read the raw data. Start the
1755 gui with the command mars.
1756
1757
1758
1759 *** Version 0.1 (2000/12/20)
1760
1761 - First official release 0.1
1762
1763 - Changes:
1764
1765 + changed calling style of MRawPixelIterator from do...while to
1766 while-loop
Note: See TracBrowser for help on using the repository browser.