1 | -*-*- END -*-*-
|
---|
2 |
|
---|
3 | *** Version 1.1 (2007/04/27)
|
---|
4 |
|
---|
5 | - general: The new class MGeomCamDwarf contains the camera geometry
|
---|
6 | for our prefered Dwarf camera and can be used to create general
|
---|
7 | geometries of roundish or hexagonal cameras.
|
---|
8 |
|
---|
9 | - mars: The default cleaning is now abolute 8.5/4.0.
|
---|
10 |
|
---|
11 | - mars: The resource file mars.rc now contains examples for MUX data
|
---|
12 |
|
---|
13 | - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
|
---|
14 | data containing only 10-bit information is still cooked down to
|
---|
15 | 8-bit, by cutting away the lowest 8-bit.
|
---|
16 |
|
---|
17 | - merpp: When reading raw data the data is now stored in a single
|
---|
18 | array. The lo-gain array is obsolete. The interface stays the same.
|
---|
19 |
|
---|
20 | - callisto: To process the new MUX data use the resource file
|
---|
21 | callisto_mux.rc
|
---|
22 |
|
---|
23 | - callisto: The -root and -raw options to read merpped raw data have
|
---|
24 | been removed
|
---|
25 |
|
---|
26 | - callisto: If the -mc option is given the sequence-name can now be
|
---|
27 | replaced by the MC sequence number
|
---|
28 |
|
---|
29 | - callisto: If the sequence file contains "MonteCarlo: Yes" the
|
---|
30 | -mc option can now be omitted
|
---|
31 |
|
---|
32 | - callisto: Started further simplification by removing obsolete
|
---|
33 | dependancies on MCalibIntensity*Cams.
|
---|
34 |
|
---|
35 | - callisto: removed unsused intensity calibration from MJCalibration
|
---|
36 | for further simplification
|
---|
37 |
|
---|
38 | - callisto: for simplification removed references to MBadPixelsIntensityCam,
|
---|
39 | MCalibrationIntensityQECam, MCalibrationIntensityRelTimeCam,
|
---|
40 | MCalibrationIntensityTestCam, and MCalibrationIntensityBlindCam
|
---|
41 | (this should at minimum change nothing at all, and at maximum
|
---|
42 | improve thing if these containers where somewhere not handled properly)
|
---|
43 |
|
---|
44 | - callisto: Added the option to write an event movie. Please use
|
---|
45 | this option with care (huge files) but exessively to understand
|
---|
46 | our events. For further documentation please refer to the
|
---|
47 | IACT wiki
|
---|
48 | (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
|
---|
49 |
|
---|
50 | - callisto: Improved binning for the pulse position check histogram
|
---|
51 |
|
---|
52 | - callisto: The code calculating the pulse position checknow takes
|
---|
53 | the pedestal into account
|
---|
54 |
|
---|
55 | - callisto: The arrival time is now stored with full precision this
|
---|
56 | helps to get rid of artefacts in histograms. For the signal this
|
---|
57 | is not necessray because it is displayed in log-scale anyhow
|
---|
58 |
|
---|
59 | - callisto: Fixed a problem with internal exclusions. Pixels which
|
---|
60 | have once been marked as unsuitable didn't get the necessary
|
---|
61 | histograms filled anymore to be rechecked with each interleaved
|
---|
62 | calibration.
|
---|
63 |
|
---|
64 | - callisto: The relative arrival time resolution (the rms of the
|
---|
65 | relative arrival time offset) is now checked against its
|
---|
66 | median and the median deviation, instead of the average
|
---|
67 | plus an absolute offset.
|
---|
68 |
|
---|
69 | - callisto: The relative arrival time offset is now calculated
|
---|
70 | w.r.t. its median not w.r.t. to an artificial reference pixel.
|
---|
71 |
|
---|
72 | - callisto: The relative time calibration now marks pixels with
|
---|
73 | outlaying offset as unsuitable
|
---|
74 |
|
---|
75 | - callisto: The interleaved relative time calibration has been switched
|
---|
76 | on. The advantage is that pixels which are marked as outliers
|
---|
77 | now can recover. An improvement over time is not expected, because
|
---|
78 | the relative time calibration seems stable.
|
---|
79 |
|
---|
80 | - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
|
---|
81 | option can now be omitted.
|
---|
82 |
|
---|
83 | - ganymed: If either the dataset file containes "MonteCarlo: Yes"
|
---|
84 | or the option "-mc" is specified as default the monte carlo datacenter
|
---|
85 | paths (/magic/montecarlo/...) are used if not overwritten in the
|
---|
86 | dataset file.
|
---|
87 |
|
---|
88 | - ganymed: The output files now contain run- and event-number for all
|
---|
89 | events, accessible as RunNumber.fVal and EvtNumber.fVal
|
---|
90 |
|
---|
91 | - ganymed: Added a plot showing the source position in the camera also
|
---|
92 | for wobble mode
|
---|
93 |
|
---|
94 | - ganymed: In addition to the existing task which can be setup to
|
---|
95 | be executed after Cut1 a final task called "EstimateEnergy"
|
---|
96 | has been added, executed before writing the final output
|
---|
97 | (ganymed00000000.root). The task setup in all three cases
|
---|
98 | can be choosen individually. (For all three(!) cases you
|
---|
99 | can for example choose MRanForestCalc. For examples see all
|
---|
100 | sponde*.rc and all ganymed*rc)
|
---|
101 |
|
---|
102 | - ganymed: If a container "MEstimatedEnergy" is found in the
|
---|
103 | parameter list (eg. because it was setup by MEstimateEnergy)
|
---|
104 | it will be written to the output file.
|
---|
105 |
|
---|
106 |
|
---|
107 |
|
---|
108 | *** Version 1.0 (2007/02/16)
|
---|
109 |
|
---|
110 | - database: Website to plot values from the database has been added.
|
---|
111 |
|
---|
112 | - database: The rate of spark events as found by star is now kept
|
---|
113 | and the rate after cleaning is now with spark events subtracted
|
---|
114 |
|
---|
115 | - general: The changes to the interpretation of phrases lead to
|
---|
116 | a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
|
---|
117 |
|
---|
118 | - general: Added example files how you can create your own calendar
|
---|
119 | (eg. as christmas present) with Mars. Just run
|
---|
120 | root macros/tutorials/calendar.C
|
---|
121 |
|
---|
122 | - general: Added a possibility to display grouped data in the plotdb.C
|
---|
123 | macro (and similar macros). This allows to plot hourly, nightly,
|
---|
124 | weekly, monthly and yearly averages.
|
---|
125 | For more details see the plotall function of the macro
|
---|
126 |
|
---|
127 | - general: fixed the error display of the camera display. It showed
|
---|
128 | wrong results.
|
---|
129 |
|
---|
130 | - general: fixed a memory leak when reading many MStatusDisplays
|
---|
131 |
|
---|
132 | - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
|
---|
133 | between a spherical and a parabolic mirror
|
---|
134 |
|
---|
135 | - callisto: We have a new pulse position check which takes the properties
|
---|
136 | of the extractor automatically into account. So no need to set
|
---|
137 | ExtractWinLeft/Right anymore. Again a check for pulses too much to the
|
---|
138 | left is done. If possible the lo-gain extraction start and hi-gain
|
---|
139 | extraction end is changed accordingly. If no proper extraction range
|
---|
140 | can be set (hi-gain too much to the left) an error is raised.
|
---|
141 |
|
---|
142 | - callisto: New swapped pixels have been found and corrected
|
---|
143 |
|
---|
144 | - callisto: Redone the signal extraction this includes:
|
---|
145 | + Unified the algorithms to extract the pedestal for all pedestal
|
---|
146 | extractions done
|
---|
147 | + Unification of hi- and lo-gain into one array
|
---|
148 | + Unification of hi- and lo-gain extraction for Spline and
|
---|
149 | Digital Filter (means now exactly the same algorithm is used,
|
---|
150 | not a copy-and-pasted one)
|
---|
151 | + Store pedestal subtracted data in a common place
|
---|
152 | + Improved extraction algorithms. If the algorithms search a
|
---|
153 | maximum but don't find one they don't return the maximum anymore
|
---|
154 | + Improved the extraction such that a information for signal
|
---|
155 | and time which is consistent is returned
|
---|
156 | + replaced the numerical spline with a (not slower) analytical
|
---|
157 | solution
|
---|
158 | + Lowered the saturation limit from 250 to 245 to make sure that
|
---|
159 | we are far away in all pixels from problems with the clock-noise
|
---|
160 | + The start of the lo-gain extraction is calculated from the hi-gain
|
---|
161 | arrival time. In case of saturation an estimation is used.
|
---|
162 | + the hi-gain window was extended to slice 16. This allows extraction
|
---|
163 | of very late pulses in single pixels or of huge hadron showers.
|
---|
164 | + Now uses the lo-gain extraction range for pedestal extraction,
|
---|
165 | not the hi-gain range in the lo-gain
|
---|
166 |
|
---|
167 | - callisto: New hi-/lo-gain calibration constants have been produced
|
---|
168 | for all periods from the statistic of the whole period. They are
|
---|
169 | now used automatically depending on the periods. The old constants
|
---|
170 | where deviation in avarega about 2%-3%. The constants are very
|
---|
171 | stable from period to period (<<1%) except for exchanged channels.
|
---|
172 | In a few cases the constants used so far were off by 1%-2% (maybe
|
---|
173 | temperature effects?)
|
---|
174 |
|
---|
175 | - callisto: To gain obsolete space we do not write the
|
---|
176 | MPedestalFundamental anymore. Also calibration and bad pixel
|
---|
177 | treatment is not done for it anymore because it has never been used.
|
---|
178 |
|
---|
179 | - callisto: Fixed a bug in the seuqence handling which caused the
|
---|
180 | light condition to be ignored
|
---|
181 |
|
---|
182 | - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
|
---|
183 | basically the same as "Cleaned" but the distribution devided into
|
---|
184 | the events fullfilling a spark cut or being rejected by it.
|
---|
185 | This cut can be changed from star.rc (see example inside) by
|
---|
186 | the "SparkCut" directive
|
---|
187 |
|
---|
188 | - star: Star displays now the average individual pixel-rate (IPR) versus
|
---|
189 | time and the average discriminator threshold (DT) of all pixels.
|
---|
190 |
|
---|
191 | - optim: fixed a problem with the optim-macros which was due to a bug
|
---|
192 | in the new phrase parsing
|
---|
193 |
|
---|
194 | - ganymed: To get a nice FalseSource plot (instead of the all-information
|
---|
195 | debug plot displayed as a standard plot) use the context menu
|
---|
196 | somewhere between the two upper plots, click on "DrawNicePlot"
|
---|
197 | and enjoy the result. (It is the same context menu which contains
|
---|
198 | the other options)
|
---|
199 | PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
|
---|
200 |
|
---|
201 | - ganymed/optim/train: The cut program, trainings- and optimization
|
---|
202 | macros could run with less files found than expected from the
|
---|
203 | sequence-files. No the execution is stopped in this case.
|
---|
204 |
|
---|
205 | - ganymed: now stores the dataset in the output file with all information
|
---|
206 | contained (as sequence number, sequence path, data path) so that the
|
---|
207 | used dataset file can be recreated complete from the output
|
---|
208 |
|
---|
209 | - sponde: now also allows the uasge of random forest
|
---|
210 |
|
---|
211 | - sponde: added a plot showing the cut efficiency
|
---|
212 |
|
---|
213 | - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
|
---|
214 | errors (eg. effecting the collection area) because the errors of the
|
---|
215 | two histograms were swapped in the calculation, which makes a difference
|
---|
216 | in the case the histograms contains weighted events. Aditionally the
|
---|
217 | totalarea was incorrectly taken into account, which results in too small
|
---|
218 | errors, which makes a difference at low statistics were the errors
|
---|
219 | or the collection area dominate.
|
---|
220 |
|
---|
221 |
|
---|
222 |
|
---|
223 | *** Version 0.10.3 (2006/10/23)
|
---|
224 |
|
---|
225 | - database: Implemented ObservationMode flag in websites.
|
---|
226 |
|
---|
227 | - database: For sequences there is now also the stoptime available on the
|
---|
228 | websites.
|
---|
229 |
|
---|
230 | - database: Removed ManuallyChanged flag from sequence-info websites,
|
---|
231 | as it is not needed anymore with the new sequence building algorithm.
|
---|
232 |
|
---|
233 | - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
|
---|
234 | Class for calculation of confidence intervals (upper limits).
|
---|
235 | Use model 3 or 4 for upper limit calculation for MAGIC observations.
|
---|
236 | Please read the class instruction of TRolke for more information.
|
---|
237 |
|
---|
238 | - general: The programs now return 0xfe if the requested resource file
|
---|
239 | doesn't exist.
|
---|
240 |
|
---|
241 | - general: Errors comming from root itself are now not output to
|
---|
242 | stderr anymore but to our default (colored) log-stream.
|
---|
243 |
|
---|
244 | - general: Changed the interface to TFormula such that now everything
|
---|
245 | is parsed by TFormula, which should allow to use phrases even
|
---|
246 | without paranthesis correctly parsed.
|
---|
247 |
|
---|
248 | - callisto: replaced the AdHoc number of effective integration slices
|
---|
249 | in the digital filter by an average of the correct number, averaged
|
---|
250 | over all possible set of weights. This also gives correct numbers
|
---|
251 | for the lo-gains which were totally wrong before.
|
---|
252 |
|
---|
253 | - callisto: drastically reduced memory consumption by not storing
|
---|
254 | all intermediate calibration results in memory anymore (we might
|
---|
255 | write them into a file in the future)
|
---|
256 |
|
---|
257 | - ganymed: To get a nice Theta-Sq plot (instead of the all-information
|
---|
258 | debug plot displayed as a standard plot) use the context menu
|
---|
259 | somewhere between the two upper plots, click on "DrawNicePlot"
|
---|
260 | and enjoy the result. (It is the same context menu which contains
|
---|
261 | the "DrawAll" option)
|
---|
262 | PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
|
---|
263 |
|
---|
264 |
|
---|
265 |
|
---|
266 | *** Version 0.10.2 (2006/10/15)
|
---|
267 |
|
---|
268 | - general: changed the building of the sequence files such, that
|
---|
269 | the source-/project name in case of wobble-sources is not the
|
---|
270 | source/project of the first data run anymore but the new generalized
|
---|
271 | wobble source/project
|
---|
272 |
|
---|
273 | - general: Added some functions to MAstro to calculate sun and
|
---|
274 | moon properties
|
---|
275 |
|
---|
276 | - general: Added two new macros (starvisday.C and starvisyear.C)
|
---|
277 | which allow to plot the visibility of several stars in one day
|
---|
278 | or of one star along one year
|
---|
279 |
|
---|
280 |
|
---|
281 |
|
---|
282 | *** Version 0.10.1 (2006/10/11)
|
---|
283 |
|
---|
284 | - general: HTML logging output was distorted... fixed.
|
---|
285 |
|
---|
286 | - general: Changed the writing of the sequencefiles such that only
|
---|
287 | as many pedestal files as giving at least 1000 pedestal events which
|
---|
288 | are nearby the first calibration run are used as pedestal runs
|
---|
289 |
|
---|
290 | - sponde: In the calculation of the collection area(s) and the
|
---|
291 | distribution for MOnte Carlo and estimated energy the error
|
---|
292 | calculation was wrong because root didn't take the errors
|
---|
293 | properly into account... fixed.
|
---|
294 |
|
---|
295 |
|
---|
296 |
|
---|
297 | *** Version 0.10 (2006/10/10)
|
---|
298 |
|
---|
299 | - general: all executables now check consistency of the root version
|
---|
300 | installed with the root version used for compilation. The return
|
---|
301 | code in this case is 255.
|
---|
302 |
|
---|
303 | - general: The algorithm to build seqeunces has been redesigned
|
---|
304 | completly. It is now more flexible in terms of a resource file
|
---|
305 | resources/sequences.rc which can be used to partly overwrite
|
---|
306 | the default algorithm and defined the important part of the
|
---|
307 | algorithm. It also takes correctly into account several ways
|
---|
308 | of taking wobble-data. Currently the new algorithm doesn't take
|
---|
309 | the number of pedestal events anymore into account (so a sequence
|
---|
310 | could have much less than 1000 pedestal events and data runs are
|
---|
311 | no-more used instead)
|
---|
312 |
|
---|
313 | - general: a lot of small changes to make the code compatible with
|
---|
314 | root 5.12/00 and gcc 4.1
|
---|
315 |
|
---|
316 | - general: Fixed some warnings thrown if more warnings are switched
|
---|
317 | on in the compiler
|
---|
318 |
|
---|
319 | - general: Added a function to MMath which returns the Median of
|
---|
320 | the distribution abs(y[i]-median) but at 68:32 division instead
|
---|
321 | of 50:50, which is somehow the median counterpart of the rms.
|
---|
322 |
|
---|
323 | - general: MAstroCatalog allows now to read calatog files (as bsc5)
|
---|
324 | even if they are compressed with gzip (recommended compression
|
---|
325 | is with "-1")
|
---|
326 |
|
---|
327 | - showplot:
|
---|
328 | + batch mode creation of image files now works with root 5.12/00
|
---|
329 | + added support for writing bmp (though it never produces
|
---|
330 | bmp which can be read by programs like xv or gimp)
|
---|
331 | + added support for xml
|
---|
332 | + added new option to start the display with a different size, by
|
---|
333 | --display-width=nnn or --display-height=nnn
|
---|
334 | + added options to define the canvas size when the display is started
|
---|
335 | --canvas-width=nnn or --canvas-height=nnn
|
---|
336 | the option can also be used for batch-mode conversion
|
---|
337 | + added an option which automatically fits the display size to the
|
---|
338 | desktop-size: --auto-size
|
---|
339 |
|
---|
340 | - merpp: didn't recognize files with the extension .raw.gz - fixed.
|
---|
341 |
|
---|
342 | - merpp: allow the reports to have 1000ms due to a bug in the camera
|
---|
343 | program.
|
---|
344 |
|
---|
345 | - callisto: New swapped pixels have been found and corrected. For
|
---|
346 | details see MRawRunHeader::FixAssignment()
|
---|
347 |
|
---|
348 | - callisto: Callisto now raises an error if one of the input files could
|
---|
349 | not be opened.
|
---|
350 |
|
---|
351 | - callisto: In some rare cases it could happen that in the signal
|
---|
352 | extraction of the digital filter the extractor returned nonsense
|
---|
353 | results due a wrong initializion of a variable (this happens in
|
---|
354 | cases in which the extracted signal is exactly zero or the
|
---|
355 | digital filter couldn't slide because of a too small extraction
|
---|
356 | window, which could happen in the lo-gain extraction)
|
---|
357 |
|
---|
358 | - callisto: The lo-gains have been marked as valid in some cases
|
---|
359 | when they got not extracted at all (deltsumlo=deltatimelo=0) because
|
---|
360 | the allowed extraction range (fLoGainLast-fLoGainFirst) was
|
---|
361 | smaller than the number of slices (fLoGainWindowSize) needed
|
---|
362 | by the lo-gain extractor
|
---|
363 |
|
---|
364 | - callisto: Updated absolute calibration constants (muon calibration)
|
---|
365 |
|
---|
366 | - callisto: fixed a bug which caused the hi-gain saturation not
|
---|
367 | to be handled properly in the spline (the position of the
|
---|
368 | saturation was calculated incorrectly)
|
---|
369 |
|
---|
370 | - callisto: fixed a bug which gave weird results if hi- _and_
|
---|
371 | lo-gain could not be extracted properly. In some cases hi-
|
---|
372 | and lo-gain have not been extracted at all and the random result
|
---|
373 | got calibrated. In other cases the hi-gain was saturating and the
|
---|
374 | lo-gain has not been extracted. For this a completly arbitraty
|
---|
375 | scale factor was applied to the result from extracting the
|
---|
376 | charge of the saturating hi-gain.
|
---|
377 |
|
---|
378 | - callisto: improves handling of extracted signal if lo- and/or
|
---|
379 | hi-gain could not be extracted properly. If no appropriate
|
---|
380 | calibration of either the signal or the arrival time is possible
|
---|
381 | the pixel is now markes as unsuitable instead of estimated.
|
---|
382 |
|
---|
383 | - callisto: Fixed a problem in the spline extraction which gave
|
---|
384 | weird results if the signal was extracted from the first (and
|
---|
385 | highest) slice (as a workaround extraction from the first
|
---|
386 | slice has been forbidden)
|
---|
387 |
|
---|
388 | - callisto: Fixed a bug regarding the use of the QE which doesn't
|
---|
389 | effect the result because the default is used anyhow.
|
---|
390 | (The bug was there since 14/07/2005)
|
---|
391 |
|
---|
392 | - callisto: Changed the default for fgLoGainStartShift to -2.4
|
---|
393 |
|
---|
394 | - callisto: Fixed a bug which caused all hi-/lo-gain calibration
|
---|
395 | factors to be always 10 for all pixels as soon as the first
|
---|
396 | calibration update has happend.
|
---|
397 |
|
---|
398 | - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
|
---|
399 | was off by more than one slice (which gives wrong values for
|
---|
400 | pixels which have saturated the hi-gain) This was a problem
|
---|
401 | mainly for timing studies, not so much for the automatic standard
|
---|
402 | analysis. Also the values for the Spline have been changed slightly:
|
---|
403 | + Digital Filter from 1.70 to 0.95
|
---|
404 | + Spline from 1.39 to 1.30
|
---|
405 | The numbers were sorted out by an extensive test in the
|
---|
406 | test-database.
|
---|
407 |
|
---|
408 | - callisto: Removed the tab showing the average calibrated arrival
|
---|
409 | time. It never gave useful information.
|
---|
410 |
|
---|
411 | - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
|
---|
412 | lo-gain pulse for data pulses if hi- and lo-gain have saturated
|
---|
413 | and both were extracted because the hi-gain was above the
|
---|
414 | LoGainSwitch.
|
---|
415 |
|
---|
416 | - callisto: Now tab "HiLoOff" which shows the offset between hi- and
|
---|
417 | lo-gain pulse position (after application of LoGainOffset, which
|
---|
418 | means in the ideal case it is 0) for data pulses if hi- and lo-gain
|
---|
419 | have saturated and both were extracted because the hi-gain was above
|
---|
420 | the LoGainSwitch.
|
---|
421 |
|
---|
422 | - callisto: After extensive tests a new threshold level for determination
|
---|
423 | of the pulse position has been found at 50phe. This is due to the
|
---|
424 | fact that for lower pulses the arrival time changes its average
|
---|
425 | behaviour dramatically. It tends to the average of the extraction
|
---|
426 | range and starts sticking to non-floating point numbers (5, 6, 7, ...)
|
---|
427 |
|
---|
428 | - callisto: Added two more plots to the calibration part. The average
|
---|
429 | extracted signal and the average extracted arrival time as
|
---|
430 | extracted by the signal extractor (This can help debugging problems
|
---|
431 | because it doesn't involve a fit)
|
---|
432 |
|
---|
433 | - star: changed the fit for the effective on time such that initial
|
---|
434 | values are calculated automatically now instead of using build
|
---|
435 | in values. This makes the fit more indepedant of the underlaying
|
---|
436 | rates. With a test of ~350 sequences in the test database it could
|
---|
437 | be shown that the new fit gives the same result +/-1sek.
|
---|
438 | The highest deviation was +5s the lowest -10s. You can now control
|
---|
439 | the bahaviour with two resource values:
|
---|
440 | MHEffectiveOnTime.FistBin: 3
|
---|
441 | MHEffectiveOnTime.NumEvents: 12000
|
---|
442 | Use FirstBin=1 and NumEvents=120 to fit the effective on time
|
---|
443 | from the resulting gamma candidates
|
---|
444 |
|
---|
445 | - star: The Center histogram in MHHillas is now by default displayed
|
---|
446 | with the colz draw-option
|
---|
447 |
|
---|
448 | - ganymed: now produces valid error codes if failed
|
---|
449 |
|
---|
450 | - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
|
---|
451 | with the option "hadronness" instead of "area" or "both" if
|
---|
452 | you want to use both cuts. The hadronness cut includes a fixed
|
---|
453 | cut in hadronness (index 8) and a fixed cut in size (index 9).
|
---|
454 |
|
---|
455 | - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
|
---|
456 | the M3Long of the anti source to be not properly evaluated
|
---|
457 | (actually is was evaluated as a unique random number) in case
|
---|
458 | of optimization with anti-theta cut switched on. This might have
|
---|
459 | lead to improper, but not necessarily wrong, optimization results.
|
---|
460 |
|
---|
461 | - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
|
---|
462 | how to use random forest
|
---|
463 |
|
---|
464 | - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
|
---|
465 | ganymed_onoff.rc. Seems to be unintentional that they were different.
|
---|
466 |
|
---|
467 | - sponde: Since the introduction of the possibility to define a
|
---|
468 | normalization energy instead of using the integral the default
|
---|
469 | was not using the integral anymore but a normalization energy of
|
---|
470 | 1GeV. It is now the integral again.
|
---|
471 |
|
---|
472 | - sponde: Fixed a problem in the weighting which did not allow
|
---|
473 | a MC slope of -1.
|
---|
474 |
|
---|
475 |
|
---|
476 |
|
---|
477 | *** Version 0.9.6 (2006/05/24)
|
---|
478 |
|
---|
479 | - general: changed the binning of the azimuthal profile of the camera
|
---|
480 | such that it is aligned with the 60deg boundaries.
|
---|
481 |
|
---|
482 | - merpp: better handling of problems with the TH, TD part of the
|
---|
483 | CC-REPORT for files older than 200507190 and 200412210
|
---|
484 | respectively
|
---|
485 |
|
---|
486 | - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
|
---|
487 |
|
---|
488 | - merpp: implementd latest changes in starguider reports (sinc 9th May)
|
---|
489 |
|
---|
490 | - callisto: if an arrival time is extracted outside the fadc range is
|
---|
491 | was set to the boundary before. Now a random number is assigned
|
---|
492 | instead to avoid unfortunate coincidences of arrival times just
|
---|
493 | by this arbitrary value.
|
---|
494 |
|
---|
495 | - callisto: added a new option to callisto.rc which allows
|
---|
496 | to set the maximum arrival time difference allowed for the
|
---|
497 | badpixel algorithm to determin whether a pixels belongs to a shower:
|
---|
498 | MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
|
---|
499 |
|
---|
500 | - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
|
---|
501 | to 0.9 as suggested by Stefan due to a recent study on the fraction
|
---|
502 | of pixels surviving the image cleaning
|
---|
503 |
|
---|
504 | - callisto: switched off error in case of "pulse is too much to the left"
|
---|
505 |
|
---|
506 | - callisto: The extraction window is not adapted anymore. This means that
|
---|
507 | the pulse is extracted from the full range. The draw-back is that the
|
---|
508 | background (pedestal) will become slightly higher. Switching on/off
|
---|
509 | the PulsePosCheck in the callisto.rc only effects filling the
|
---|
510 | histograms.
|
---|
511 | WARNING: If the pulse is too much to the left data is calibrated!
|
---|
512 | Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
|
---|
513 | in the database to make sure that your data is valid!
|
---|
514 |
|
---|
515 | - star: Show also the number of stars correlated correctly by the
|
---|
516 | starguider
|
---|
517 |
|
---|
518 | - ganymed: implemented a new class (MHThetaSqN) which allows to use more
|
---|
519 | than one off-source region in wobble-mode. To use it add the following to
|
---|
520 | your ganymed_wobble.rc:
|
---|
521 | + MJCut.NameHist: MHThetaSqN (switch the new feature on)
|
---|
522 | + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
|
---|
523 | + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
|
---|
524 | + Cut1.ThetaCut: None
|
---|
525 | + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
|
---|
526 |
|
---|
527 | - ganymed: in the case the latest report is older than a default (currently
|
---|
528 | one minute) and the current report will be skip the starguider
|
---|
529 | correction and calibration will be reset. The maximum age can be
|
---|
530 | setup from ganymed.rc by (minutes):
|
---|
531 | MPointingDevCalc.MaxAge: 1.5
|
---|
532 |
|
---|
533 | - ganymed: A first implementation showing all size-bins for the theta-sq
|
---|
534 | resp. alpha-plots in a single tab automatically
|
---|
535 |
|
---|
536 |
|
---|
537 |
|
---|
538 | *** Version 0.9.5.1 (2006/05/05)
|
---|
539 |
|
---|
540 | - general: Added a new option "zdiff" to the Makefile which runs
|
---|
541 | "cvs diff" as "make diff" would do, but with compression
|
---|
542 |
|
---|
543 | - general: accelerated MTFillMatrix (used for eample in all training
|
---|
544 | and optimization macros) by skipping some obsolete calles in the
|
---|
545 | eventloop the first and second loop could be accelerated by ~20%
|
---|
546 |
|
---|
547 | - general: Added a missing feature in the MFilterList class which
|
---|
548 | prevented MFEnergySlope from working correctly in trainenergy.C
|
---|
549 |
|
---|
550 | - general: Accelerated the random forest training and usage a bit
|
---|
551 |
|
---|
552 | - merpp: Adapted to new raw data file format version 6
|
---|
553 |
|
---|
554 | - merpp: fixed a problem with reading the starguider reports
|
---|
555 | after 6.3.2006
|
---|
556 |
|
---|
557 | - callisto: At some times six pixels had to be exchanged manually in the
|
---|
558 | data. If the pixels to be swaped are both not found, an error was raised
|
---|
559 | and calibration was stopped. Now it is assumed they are intentially not
|
---|
560 | mapped and the Error has been changed to a Warning.
|
---|
561 |
|
---|
562 | - star: Added new image cleaning based on the arrival time of the shower.
|
---|
563 | The new cleaning can be accessed using the parameter "Time" instead of
|
---|
564 | the the old one (like "Absolute) in the star.rc-file.
|
---|
565 | Recommended parameters:
|
---|
566 | + MImgCleanStd.CleanLevel1: 8.2
|
---|
567 | + MImgCleanStd.CleanLevel2: 5
|
---|
568 | + MImgCleanStd.CleanRings: 2
|
---|
569 | + MImgCleanStd.KeepSinglePixels: No
|
---|
570 |
|
---|
571 | - star: Simplified the calculation of the effective on time. By letting
|
---|
572 | the fit start in the third bin the result should become more stable.
|
---|
573 | The fit quality is now ignored for the theta-plot which is not used
|
---|
574 | in the analysis later. Still better pre-cut which, for example,
|
---|
575 | remove events triggered by car-light (rate changing on a short
|
---|
576 | time-scale) are missing.
|
---|
577 |
|
---|
578 | - macros: optimonoff.C, optimwobble.C: implemented a new strategy
|
---|
579 | for optimization (kWeakSource) which is suggested by the Berlin
|
---|
580 | people for weak sources.
|
---|
581 |
|
---|
582 | - macros: plotdb.C:
|
---|
583 | + if no dataset and no time-interval is given only sequences with
|
---|
584 | an effective on-time above five minutes are plotted anymore
|
---|
585 | + added a new tab "RelTime" displaying the relative on-time
|
---|
586 | (effective on-time divided by the observation time)
|
---|
587 |
|
---|
588 | - macros: optim*.C: by skipping some obsolete calles in the eventloop
|
---|
589 | the optimization became a lot faster
|
---|
590 |
|
---|
591 | - ganymed: In the second loop the MHNewImagePar histograms disapeared.
|
---|
592 | To display them just delete the pads displayed on top.
|
---|
593 |
|
---|
594 | - ganymed: fixed a bug which could cause strange behaviour in wobble
|
---|
595 | mode if no starguider information was available due to an incorrect
|
---|
596 | initialization of the starguider calibration
|
---|
597 |
|
---|
598 | - ganymed: The scale region in the False Source Plot (MHDisp) can now
|
---|
599 | be changed from within the plot. It can also be setup from the
|
---|
600 | resource file using:
|
---|
601 | + MHDisp.fScaleMin: 0.325
|
---|
602 | + MHDisp.fScaleMax: 0.475
|
---|
603 |
|
---|
604 | - ganymed, showplot: Fixed a problem with the fit to the off-data
|
---|
605 | (HistOff) which could cause a time lag or an inifinite loop.
|
---|
606 | The bug did not effect the results at all.
|
---|
607 |
|
---|
608 | - sponde: Added a new tab showing the effective collection area after
|
---|
609 | trigger (including the software trigger)
|
---|
610 |
|
---|
611 | - sponde: MMcSpectrumWeight has a new option which allows to define
|
---|
612 | the scaling factor not by the integral of the events but at
|
---|
613 | a defined energy:
|
---|
614 | e.g. MMcSpectrumWeight.NormEnergy: 200
|
---|
615 |
|
---|
616 | - MTFillMatrix, sponde: by skipping some obsolete calles in the
|
---|
617 | eventloops the loop could be accelerated by ~20%
|
---|
618 |
|
---|
619 |
|
---|
620 |
|
---|
621 | *** Version 0.9.5 (2006/03/13)
|
---|
622 |
|
---|
623 | - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
|
---|
624 | and added the standard Disp-parametrization
|
---|
625 |
|
---|
626 | - macros: added a new macro datacenter/macros/plotstat.C allowing
|
---|
627 | to plot statistics about the data processing
|
---|
628 |
|
---|
629 | - macros: added a new macro to plot the muon correction coefficients
|
---|
630 | versus period (macros/plot/mucal.C)
|
---|
631 |
|
---|
632 | - showplot: path inflation for ganymed files was broken
|
---|
633 |
|
---|
634 | - callisto: Fixed an important bug. When the number of saturating pixels
|
---|
635 | were calculated the bad pixel information already available from the
|
---|
636 | calibration was ignored. This yields wrong values in case pixels
|
---|
637 | are broken and saturate all the time or randomly.
|
---|
638 |
|
---|
639 | - callisto: Updated Muon calibration constants. Spline data now also uses
|
---|
640 | different values for different periods
|
---|
641 |
|
---|
642 | - star: The time-evolution shown in the effective on-time plot now displays
|
---|
643 | the axis range (if there are no holes it should be similar to the
|
---|
644 | effective on-time)
|
---|
645 |
|
---|
646 | - star: Added two new image parameters:
|
---|
647 | + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
|
---|
648 | the three pixels next to the center of gravity and the size
|
---|
649 | + MNewImagePar.fConcCore: The ratio of the signals of all
|
---|
650 | pixels inside or touching the ellipse and the size
|
---|
651 |
|
---|
652 | - ganymed: now stops in requested source isn't found in catalog file
|
---|
653 |
|
---|
654 | - ganymed: Many improvements to the phi-plot in wobble mode:
|
---|
655 | + with a template the ideal background is displayed
|
---|
656 | + a possible camera inhomogeneity is taken into account
|
---|
657 | + the anti theta cut is better supported
|
---|
658 | + the phi cut is automatically calculated from the theta cut
|
---|
659 | See the examples in ganymed_wobble.rc for more details.
|
---|
660 |
|
---|
661 | - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
|
---|
662 | times the bin-width instead of the absolute energy
|
---|
663 |
|
---|
664 | - ganymed: New cuts for on/off and wobble mode
|
---|
665 |
|
---|
666 | - ganymed: The smearing of the False Source plot has been increased
|
---|
667 | to 0.06
|
---|
668 |
|
---|
669 | - ganymed: The starguider calibration can now be changed from the
|
---|
670 | resource file.
|
---|
671 | See the examples in ganymed*.rc for more details.
|
---|
672 |
|
---|
673 | - ganymed: added a new option for on-/off-observations
|
---|
674 | MJCut.RandomSourcePosition
|
---|
675 | If switched on the distribution of observation time of the source
|
---|
676 | position in the camera is calculated from the on-data and randomly
|
---|
677 | applied with this distrbution to the off-data.
|
---|
678 |
|
---|
679 | - ganymed: by skipping some obsolete calles in the eventloop the
|
---|
680 | first and second loop could be accelerated by ~20%
|
---|
681 |
|
---|
682 | - ganymed: The default in ganymed_onoff.rc is now to determin the source
|
---|
683 | position in the off-data randomly according to its distribution in the
|
---|
684 | on-data.
|
---|
685 |
|
---|
686 |
|
---|
687 |
|
---|
688 | *** Version 0.9.4.3 (2006/02/13)
|
---|
689 |
|
---|
690 | - general: Fixed a bug in most of the programs which prevented the
|
---|
691 | compile date in the startup message to be displayed
|
---|
692 |
|
---|
693 | - general: Simplified program calls. The following abbreviations
|
---|
694 | are now possible:
|
---|
695 | showlog callisto 55599
|
---|
696 | showplot signal 55599
|
---|
697 | star 55599
|
---|
698 | callisto 55999
|
---|
699 | ganymed 2
|
---|
700 | In this cases the corrsponding root-, log-, sequence- or dataset-
|
---|
701 | filename is automatically compiled using the default datacenter
|
---|
702 | paths ("/magic/*")
|
---|
703 |
|
---|
704 | - general: Fixed a long outstanding bug which made axis tick marks
|
---|
705 | disappear if MDataFormula was used (eg. abs(x))
|
---|
706 |
|
---|
707 | - general: Updated MMath with new functions to calculate the results of
|
---|
708 | a exponential, logarithmic and powerlaw fits analytically.
|
---|
709 |
|
---|
710 | - general: Updated some macros with comments:
|
---|
711 | + macros/optim/optimdisp.C
|
---|
712 | + macros/optim/optimenergy.C
|
---|
713 | + macros/optim/optimwobble.C:
|
---|
714 |
|
---|
715 | - general: MTFillMatrix (the class to fill one or two MHMatrix from
|
---|
716 | files) now allows adding a pre-cut like in the optimization. E.g. this
|
---|
717 | is useful to perform g/h-separation cuts before training the random
|
---|
718 | forest.
|
---|
719 |
|
---|
720 | - general: Between the rund 53300 and 68754 the pixels 553-558 were not
|
---|
721 | correctly assigned in the raw data assignement table. A fix to correct
|
---|
722 | the assignment tabel have been implemented.
|
---|
723 |
|
---|
724 | - general: MAstroCatalog now allows rotating of the sky-grid and stars
|
---|
725 | by 90, 180 and 270 deg.
|
---|
726 |
|
---|
727 | - general: the macro plotdb.C now allows to highlight sequences belonging
|
---|
728 | to a datset. For more details see the descritions in the macro.
|
---|
729 |
|
---|
730 | - StatusDisplay: Fixed the algorithm to calculate the size ratio
|
---|
731 | of the display, it gave wrong results espacially for big sizes.
|
---|
732 | Now the embedded canvas should always have a ratio width/height=3/2.
|
---|
733 | The "Size" options have been updated with values fitting the 3/2
|
---|
734 | size ratio.
|
---|
735 |
|
---|
736 | - RanForest:
|
---|
737 | + Updated the random forest classes to support also the
|
---|
738 | regression method implemented by Thomas H.
|
---|
739 | + added new tutorial macro how to train the random forest
|
---|
740 | for energy estimation (macros/optim/rfenergyest.C)
|
---|
741 | + new classes to train the random forest (still in development)
|
---|
742 | mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
|
---|
743 | + new tutorial macros for random forest training in macros/train
|
---|
744 | trainenergy.C, traindisp.C, trainseparation.C
|
---|
745 |
|
---|
746 | - mars: now allows to setup a cut in the resource file mars.rc to choose
|
---|
747 | the events to be displayed, eg:
|
---|
748 | Cut.Condition: {0} && {1}
|
---|
749 | Cut.0: MHillas.fSize>100
|
---|
750 | Cut.1: MHillas.fSize<900
|
---|
751 |
|
---|
752 | - merpp: Made aware of the new .rep format 200510250. This includes
|
---|
753 | interpretation of the Receiver Board Temperatures (MCameraRecTemp),
|
---|
754 | the discriminator thresholds (MCameraTD) and the disciminator
|
---|
755 | delays (MCameraTD). All of them come with the CC report and are therefor
|
---|
756 | written to the CC tree.
|
---|
757 |
|
---|
758 | - callisto: fixed a bug in the calculation of the arrival times in
|
---|
759 | the Digital Filter. They were all shifted by the same amount
|
---|
760 | fHiGainFirst. This caused an offset in the order of the position of
|
---|
761 | the left border of the extraction window in the times calculated
|
---|
762 | from high-gain and from low-gain. The bug effected only the absolute
|
---|
763 | arrival times. The bug was there since 30.1.2005.
|
---|
764 |
|
---|
765 | - callisto: Changed the ExtractionWindow for the pulse position check
|
---|
766 | such that the camera inhomogeneity becomes as less as possible and
|
---|
767 | comparable to the pulso position check switched off. More details
|
---|
768 | on the study will be given at our result web-page.
|
---|
769 |
|
---|
770 | - ganymed: ganymed.rc, ganymed_onoff.rc:
|
---|
771 | changed to new cuts trained with 1ES1218 and Crab-data
|
---|
772 | for maximum sigma*log10(excess)
|
---|
773 |
|
---|
774 | - ganymed: In addition to the Hadronness calculator (CalcHadronness)
|
---|
775 | a new option was implemented to estimate Disp (CalcDisp)
|
---|
776 |
|
---|
777 | - ganymed: Implemented two new options which allow
|
---|
778 | to overwrite the default path to search for the sequence files
|
---|
779 | --ins=/magic/sequences
|
---|
780 | and where to search for the image data
|
---|
781 | --ind=/magic/data/star
|
---|
782 |
|
---|
783 | - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
|
---|
784 | dx/dy from the resource file by
|
---|
785 | MSrcPosCorrect.Dx
|
---|
786 | MSrcPosCorrect.Dy
|
---|
787 |
|
---|
788 | - ganymed: fixed reading the source catalog. Only as many chars
|
---|
789 | as the requested source name had were compared (If a source
|
---|
790 | "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
|
---|
791 | were requested it could happen that the coordinates of
|
---|
792 | "1ES1218" were read) The source coordinates are now printed
|
---|
793 | in addition to its name to the logging output.
|
---|
794 |
|
---|
795 | - ganymed: changed the background fit in the case of a ThetaSq function
|
---|
796 | from a polynomial to a exponential, this should give a big improvement
|
---|
797 | for on-only analysis'
|
---|
798 |
|
---|
799 | - ganymed/sponde: Calculation of the error of single size-/energy-
|
---|
800 | bins now uses Li/Ma (5) instead of LiMa (17)
|
---|
801 |
|
---|
802 | - sponde: Added a plot E^2*dN/dE
|
---|
803 |
|
---|
804 | - sponde: The energy estimator plot should now show values like
|
---|
805 | they are commonly used.
|
---|
806 |
|
---|
807 | - sponde: Now MMcSpectrumWeight also excepts formulas with two X
|
---|
808 | (a powerlaw with cutoff didn't work before)
|
---|
809 |
|
---|
810 |
|
---|
811 |
|
---|
812 | *** Version 0.9.4.2 (2005/10/01)
|
---|
813 |
|
---|
814 | - general: added new tutorial macro macros/tutorials/threshold.C:
|
---|
815 | how to calculate the threshold
|
---|
816 |
|
---|
817 | - general: added a new game. Start it from the interpreter with
|
---|
818 | MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
|
---|
819 | and MagicReversi)
|
---|
820 |
|
---|
821 | - general: neighbor pixels in MGeoms are now sorted clockwise
|
---|
822 |
|
---|
823 | - merpp: made aware of new format 20050829-0
|
---|
824 |
|
---|
825 | - callisto: New scale factors from muon analysis, stored in new
|
---|
826 | resource file resources/calibration.rc
|
---|
827 |
|
---|
828 | - callisto: MBadPixelsCalc now raises an error instead of simply stopping
|
---|
829 | the eventloop if something went wrong. This is necessary for the
|
---|
830 | automatic processing
|
---|
831 |
|
---|
832 | - callisto: Implemented a new treatment for the time information
|
---|
833 | developed by S.Ruegamer, this should give much better response than
|
---|
834 | the old very primitive algorithm. This is especially important
|
---|
835 | for bad pixels due to bright stars as Ceta-Tauri (btw: the old
|
---|
836 | treatment was buggy! As neighbor pixels to interpolate the
|
---|
837 | arrival times always the pixels 0 to 5 were taken)
|
---|
838 |
|
---|
839 | - callisto: In addition to the new treatment of arrival times the
|
---|
840 | decision of the treatment whether a pixel contains shower
|
---|
841 | information or not is used to improve the signal interpolation
|
---|
842 | further. Previously interpolated pixels showed a non-zero signal
|
---|
843 | do the peak searching signal extractors. Having a signal pixel
|
---|
844 | beside raised the signal above the cleaning level. Thus the
|
---|
845 | pixel survived cleaning to often but with a too low mean signal.
|
---|
846 | By replacing empty pixels with a gaus (mean and rms from the
|
---|
847 | corresponding Area entries in MPedPhotCam) this effect can
|
---|
848 | be supressed.
|
---|
849 |
|
---|
850 | - callisto: The status "unmapped" (for pixel which cannot be interpolated)
|
---|
851 | got lost when the events were stored by the calibration... fixed.
|
---|
852 | (This was no problem for normal image cleaning because the pixel
|
---|
853 | content was artificially set to 0 not surviving standard cleaning
|
---|
854 | algorithm)
|
---|
855 |
|
---|
856 | - callisto: Fixed a bug which caused the random and peak-search pedestal
|
---|
857 | extracted with an extractor to be exchanged for the first (roughly)
|
---|
858 | 500 events (*Extractor and *ExtractorRndm).
|
---|
859 | (They were simply exchanged in callisto.cc) This bug might have been
|
---|
860 | introduced in Mars 0.9.4 when the order of calculation of the two
|
---|
861 | types of pedestal in callisto got exchanged. The bug only effects
|
---|
862 | the first seconds of data of each sequence.
|
---|
863 |
|
---|
864 | - star: Taking the arrival time of Muons into account the calculation
|
---|
865 | of the parameters could be made independant of the noise
|
---|
866 | (pedestal rms). The dependance was due to the bias of the peak search
|
---|
867 | extractor. Now only a ZA dependamcy is left which is not yet fully
|
---|
868 | understood.
|
---|
869 |
|
---|
870 | - ganymed: The sequences were still not sorted correctly in any case,
|
---|
871 | because they were sorted by the full qualified path name. Now they
|
---|
872 | are sorted by their sequence number.
|
---|
873 |
|
---|
874 | - ganymed: new values for the spark-event-cut
|
---|
875 |
|
---|
876 | - sponde: required missing MEnergyEst from ganymed.root... fixed.
|
---|
877 |
|
---|
878 |
|
---|
879 |
|
---|
880 | *** Version 0.9.4.1 (2005/08/18)
|
---|
881 |
|
---|
882 | - callisto: fixed some problems with the calibration in case of
|
---|
883 | inteleaved events. Therefor the final and some intermediate
|
---|
884 | fits are skipped which would take place on partly filled #
|
---|
885 | histograms and gave wrong results or failed completely.
|
---|
886 |
|
---|
887 | - callisto: If the intermediate finalization of the histograms
|
---|
888 | calculating the mean charge of the calibration signal fails
|
---|
889 | it is counted now and printed in PostProcess of MCalibCalcFromPast.
|
---|
890 |
|
---|
891 | - ganymed: Fixed some bugs which caused problems in On-only mode.
|
---|
892 | Still the false source plot doesn't give reasonable results.
|
---|
893 |
|
---|
894 |
|
---|
895 |
|
---|
896 | *** Version 0.9.4 (2005/08/05)
|
---|
897 |
|
---|
898 | - general: Fixed the ZA binning. It did not correctly fit the
|
---|
899 | MC binning
|
---|
900 |
|
---|
901 | - general: Added a class to correct for the missfocussing in
|
---|
902 | April (MSrcPosCorrect)
|
---|
903 |
|
---|
904 | - general: Random Forest energy estimator should now work properly
|
---|
905 |
|
---|
906 | - general: MHCamera now displays the profiles in deg instead of mm
|
---|
907 |
|
---|
908 | - general: MH::SetPalette offers a lot of new palettes
|
---|
909 |
|
---|
910 | - general: MHillas - the case of CorrXY==0 is now handled properly
|
---|
911 |
|
---|
912 | - general: implemented the possibility to change the line and
|
---|
913 | marker style of a sky-grid drawn by MAstroCatalog
|
---|
914 |
|
---|
915 | - general: Runs in sequences and datasets are now automatically
|
---|
916 | ordered (it is assumed that the order of their filenames correctly
|
---|
917 | represents the order of observations) to ensure correct reading
|
---|
918 | of the subsystem data
|
---|
919 |
|
---|
920 | - general: Runs cannot be added to a sequence twice anymore. Also
|
---|
921 | Sequences cannot be added twice anymore to a dataset.
|
---|
922 |
|
---|
923 | - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
|
---|
924 | It gave wrong results by 1./2pi
|
---|
925 |
|
---|
926 | - showplot: got a new option to start a root interpreter, too
|
---|
927 |
|
---|
928 | - mars: now displays a rough estimate of Disp and the third moment
|
---|
929 |
|
---|
930 | - mars: now displays the event time MTime if available
|
---|
931 |
|
---|
932 | - mars: show muon parameters graphically
|
---|
933 |
|
---|
934 | - mars: now the file to open can be given as commandline
|
---|
935 | argument
|
---|
936 |
|
---|
937 | - merpp: Added support for new arehucas version >= 200507190
|
---|
938 | implementing values for three temperature sensors in the
|
---|
939 | counting house (MCameraAUX) and the name of the HV settings file
|
---|
940 | (MCameraHV).
|
---|
941 |
|
---|
942 | - merrp: Also fixed some problems with wrong versions numbers stated
|
---|
943 | by arehucas and implemented some fixed for old versions (<200407070)
|
---|
944 |
|
---|
945 | - callisto: MCalibrationHiLoCam can now be printed from its context
|
---|
946 | menu, eg in the TBrowser
|
---|
947 |
|
---|
948 | - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
|
---|
949 | - 1.39 (MExtractTimeAndChargeSpline)
|
---|
950 | - 1.40 (MExtractTimeAndChargeDigitalFilter)
|
---|
951 | This is important mainly for timing studies.
|
---|
952 |
|
---|
953 | - callisto: Changed limits in MHCalibrationChargeCalc from
|
---|
954 | - -100.125 to -98 (fgChargeHiGainFirst)
|
---|
955 | - 1899.875 to 1902. (fgChargeHiGainLast)
|
---|
956 | - -100.25 to -99 (fgChargeLoGainFirst)
|
---|
957 | - 899.75 to 901. (fgChargeLoGainLast)
|
---|
958 | Introduced new limits:
|
---|
959 | - fgNumLoGainBlackoutLimit: 0.05
|
---|
960 | - fgLoGainBlackoutLimit: 3.5
|
---|
961 | - fgLoGainPickupLimit: 3.5
|
---|
962 |
|
---|
963 | - callisto: The handling of automatic weights for the digital filter
|
---|
964 | has been improved. There are now new calibration weights special
|
---|
965 | for Monte Carlo calibrations.
|
---|
966 |
|
---|
967 | - callisto: Updated Muon scale with latest results (1% difference
|
---|
968 | for most data, 5% for Mar/Apr'05)
|
---|
969 |
|
---|
970 | - callisto: use a new criterium to exclude bad pixels: If the high-gain
|
---|
971 | was saturated and the blackout-events in the low-gain exceed the
|
---|
972 | fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
|
---|
973 | This excludes those pixels which have a saturating high-gain
|
---|
974 | channel, but the low-gain switch does not switch often enough
|
---|
975 | to make the distribution reliable.
|
---|
976 |
|
---|
977 | - callisto: fix a bug counting the number of saturated events. Up to now,
|
---|
978 | the number of saturated slices was counted (which is one for a not too
|
---|
979 | high number), but for some (pathological) pixels, many more slices
|
---|
980 | saturated and produced wrong limits.
|
---|
981 |
|
---|
982 | - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
|
---|
983 | + MCalibrationRelTimeCam.CheckFitResults: Yes
|
---|
984 | + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
|
---|
985 | + MCalibrationRelTimeCam.CheckHistOverflow: Yes
|
---|
986 | + MCalibrationRelTimeCam.CheckOscillations: Yes
|
---|
987 |
|
---|
988 | - callisto: introduce max. number of events for intercalibration,
|
---|
989 | the rest gets skipped. Default: 4096
|
---|
990 | The calibration causes too many un-reliable pixels if more
|
---|
991 | than about 5000 events are treated (@500 Hz) because of the
|
---|
992 | mode hopping of the VCSels. However, in the past, some
|
---|
993 | calibration runs have been taken (erroneously) with more
|
---|
994 | than 5000 events, especially the intensity scans where
|
---|
995 | a good precision is needed.
|
---|
996 |
|
---|
997 | - callisto: Set UseExtractorRes to kTRUE, will raise the number of
|
---|
998 | photo-electrons for the spline extractor by 1-2% (correctly).
|
---|
999 |
|
---|
1000 | - callisto: The intercalibration is now done using a full f-factor
|
---|
1001 | method instead of a simple update. This makes things slower but
|
---|
1002 | more reliable in terms of gain-fluctuations and sudden VCSEL gain
|
---|
1003 | changes.
|
---|
1004 |
|
---|
1005 | - callisto: MPedestalY3 now uses the same extraction range as the data
|
---|
1006 | as calculated by MPedestalY2
|
---|
1007 |
|
---|
1008 | - callisto: A check of the fraction of allowed unsuitable (10%) and
|
---|
1009 | unreliable (30%) pixels has been addded when the conversion is
|
---|
1010 | calculated from interleaved events
|
---|
1011 |
|
---|
1012 | - star: fixed a bug which caused MEffectiveOnTime containers not to
|
---|
1013 | be written. In the worst case they were skipped almost all, in the
|
---|
1014 | best case they were all ok. It depends on how often the new value
|
---|
1015 | was assigned just with an event which was skipped later by another
|
---|
1016 | task
|
---|
1017 |
|
---|
1018 | - star: new histograms MHPointing and MHRate
|
---|
1019 |
|
---|
1020 | - star: New tab (Currents) displaying the time evolution of the mean
|
---|
1021 | DC currents
|
---|
1022 |
|
---|
1023 | - star: New tab (MeanRms) displaying the time volution of the mean
|
---|
1024 | Pedestal Rms
|
---|
1025 |
|
---|
1026 | - star: Output now contains MReportStarguider
|
---|
1027 |
|
---|
1028 | - star: Improved muon analysis. Due to the absense of a constant
|
---|
1029 | for the gaus fit for arc width and the fact that the arcwidth
|
---|
1030 | plot was a histogram instead of a profile the resulting psf
|
---|
1031 | became pedestal rms dependant
|
---|
1032 |
|
---|
1033 | - ganymed: added new plot (MHPhi) for wobble mode as described in
|
---|
1034 | http://www.astro.uni-wuerzburg.de/results/ringmethod/
|
---|
1035 |
|
---|
1036 | - ganymed: corrects now (correctly?) for the misspointing in
|
---|
1037 | May/April 05
|
---|
1038 |
|
---|
1039 | - ganymed: Two new default templates for ganymed.rc are avilable:
|
---|
1040 | ganymed_onoff.rc and ganymed_wobble.rc
|
---|
1041 |
|
---|
1042 | - ganymed: The first version of MFMagicCuts has been released
|
---|
1043 |
|
---|
1044 | - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
|
---|
1045 |
|
---|
1046 | - ganymed, sponde: There are two new options to determin the number
|
---|
1047 | of bins for the signal region (NumBinsSignal) and the number of
|
---|
1048 | total bins (NumBinsTotal) in the MHThetaSq histogram
|
---|
1049 |
|
---|
1050 | - ganymed: optimized palettes for MHDisp
|
---|
1051 |
|
---|
1052 | - ganymed: Fixed an important bug when using ThetaSq as fit function:
|
---|
1053 | The result for the sigma of the gauss(sqrt(x)) fit was a factor
|
---|
1054 | sqrt(2) to large
|
---|
1055 |
|
---|
1056 | - ganymed: The false source plot (MHDisp) is now based on Disp
|
---|
1057 | and a background model determined in the first loop is
|
---|
1058 | subtracted
|
---|
1059 |
|
---|
1060 | - ganymed: MFMagicCuts are now available in the cvs. The correct
|
---|
1061 | solution for the disp ambiguity problem is now calculated using
|
---|
1062 | the third moment. The third moment cut therefor is skipped.
|
---|
1063 |
|
---|
1064 | - ganymed: Output now contains "Disp [MParameterD]" which sign is
|
---|
1065 | already determined by the third moment along the major axis and
|
---|
1066 | so its actual sign is aligned along the major axis of the shower.
|
---|
1067 |
|
---|
1068 | - ganymed: If starguider data is available it is taken into account
|
---|
1069 | when calculating the source position. This is especially important
|
---|
1070 | for wobble data at high zenith angles and culmination data.
|
---|
1071 |
|
---|
1072 | - ganymed: If available the starguider data is taken into account as
|
---|
1073 | good as it is possible without a starguider calibration. To switch
|
---|
1074 | it off add
|
---|
1075 | MPointingDevCalc.MaxAbsDev: -1
|
---|
1076 | to your ganymed.rc
|
---|
1077 |
|
---|
1078 | - sponde: the zenith angle distribution is now weighted instead of
|
---|
1079 | choosen by default. This gurantees higher statistics in the highest
|
---|
1080 | and lowest energy bins. To switch this behaviour off use...
|
---|
1081 |
|
---|
1082 | - sponde: now automatically displays the energy threshold
|
---|
1083 |
|
---|
1084 |
|
---|
1085 |
|
---|
1086 | *** Version 0.9.3 (2005/06/03)
|
---|
1087 |
|
---|
1088 | - general: MMcEvt now derived from MMcEvtBasic which should
|
---|
1089 | have no influence on compatibility with older camera files
|
---|
1090 |
|
---|
1091 | - general: Implemented a new option to MReadReports which allows
|
---|
1092 | to force reading of the first event of some trees (eg. Drive-tree)
|
---|
1093 | before any other tree.
|
---|
1094 |
|
---|
1095 | - general: Made a fix to MPointingPosCalc which assumes that the
|
---|
1096 | run-type is real-data if Process is called before ReInit, such
|
---|
1097 | that also the very first Drive-events in a run are treated
|
---|
1098 | correctly.
|
---|
1099 |
|
---|
1100 | - shoplot now displays the filename in the title bar of the window
|
---|
1101 |
|
---|
1102 | - merpp: new options: --auto-time-start --auto-time-stop which
|
---|
1103 | allow to cut updating with slow-control at the start- or
|
---|
1104 | (previousle --auto-time only allowed: and) stop-time of
|
---|
1105 | the run stored in the runheader.
|
---|
1106 |
|
---|
1107 | - callisto: changed default of fgFallTimeHiGain in
|
---|
1108 | MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
|
---|
1109 | already set as default in callisto_Dec04Jan05.rc
|
---|
1110 |
|
---|
1111 | - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
|
---|
1112 | now changes the filename for new weights automatically for
|
---|
1113 | cosmics, MC and for different calibration colors.
|
---|
1114 |
|
---|
1115 | - callisto: a problem with the order of some code cause the
|
---|
1116 | name of the weights file in MPedestalY2 to be ignored.
|
---|
1117 | Wrongly the calibration_UV weights were used instead
|
---|
1118 | of the cosmics weights set in callisto.rc.
|
---|
1119 |
|
---|
1120 | - callisto: should allow ct1 pulser data when the color is
|
---|
1121 | explicitly set also for pretty new runs
|
---|
1122 |
|
---|
1123 | - callisto: a new option (MCalibrateData.ScaleFactor) allows
|
---|
1124 | to introduce an additional scale factor (should be around 1)
|
---|
1125 | to adapt for slight deviations in different extractors from
|
---|
1126 | the MC calibration. For MC calibrations the scale factor
|
---|
1127 | is fixed to 1
|
---|
1128 |
|
---|
1129 | - callisto: MFCosmics should handle very high signals a bit
|
---|
1130 | more accurate now
|
---|
1131 |
|
---|
1132 | - callisto: when calculating the mean pedestal rms for different
|
---|
1133 | pixel sizes or sectors also kUnsuitableEvt is now taken into
|
---|
1134 | account - not only kUnsuitableRun
|
---|
1135 |
|
---|
1136 | - callisto: '-raw' option is now the default
|
---|
1137 |
|
---|
1138 | - callisto: A dead pixel check has been implemented in MJPedestalC2.
|
---|
1139 | This has the advantage that mean values in the calibration (eg
|
---|
1140 | arrival times) are calculated more accuratly.
|
---|
1141 |
|
---|
1142 | - callisto: In the resource file callisto_Dec04Jan05.rc
|
---|
1143 | MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
|
---|
1144 |
|
---|
1145 | - callisto: new Hi-/Lo-Gain intercalibration constants
|
---|
1146 | hilocalib_sp1.root and hilocalib_sp1_mc.root
|
---|
1147 |
|
---|
1148 | - callisto: changed default for MJPedestalY2.MaxEvents
|
---|
1149 | from 2000 to 5000 like in callisto_Dec04Jan05.txt
|
---|
1150 |
|
---|
1151 | - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
|
---|
1152 | has changed from 9.0 to 6.0. This is necessary to exclude two very
|
---|
1153 | ringing pixels in September which - when kept - destroy the image
|
---|
1154 | cleaning around them (Markus G.)
|
---|
1155 |
|
---|
1156 | - callisto: (!) The Muon analysis of all data taken so far has
|
---|
1157 | suggested that different extractors give slightly different
|
---|
1158 | absolute results after calibration, due to there different
|
---|
1159 | handling of the calibration- and cosmics pulse shape. Although
|
---|
1160 | the over all calibration seems to be a bit to pesimistic (or
|
---|
1161 | the MC seems to be a little bit - 3-5% - too much attenuated).
|
---|
1162 | There for correction factors have been introduced which correct
|
---|
1163 | the calibration constants by
|
---|
1164 | 0.956937799 for Digital Filter (callisto.rc)
|
---|
1165 | and
|
---|
1166 | 0.904159132 for Spline (callisto_Dec04Jan05.rc)
|
---|
1167 | calibration. The main advantage is, that both data types can
|
---|
1168 | be easily analysed together and compared to the same MC sample.
|
---|
1169 | The factors are choosen such, that the reference is now a
|
---|
1170 | Monte Carlo sample calibrated with Digital Filter (callisto.rc)
|
---|
1171 |
|
---|
1172 | - star: fixed a bug which caused the first bin of the histograms
|
---|
1173 | vs time to disapear in PostProcess. This gave wrong results
|
---|
1174 | on the screen. The output and all following programs not
|
---|
1175 | directly accessing the histograms haven't been affected
|
---|
1176 |
|
---|
1177 | - star, ganymed: Made sure that always the first Drive-tree event
|
---|
1178 | is read and Processed before the first data event was read.
|
---|
1179 |
|
---|
1180 | - ganymed: implemented the possibility to replace the standard
|
---|
1181 | false source plot with a different one. For example: If
|
---|
1182 | you want to use a Disp based FS plot use the resource:
|
---|
1183 | NameHistFS: MHDisp
|
---|
1184 | For details about the requirements of these plots look
|
---|
1185 | at the corresponding classes
|
---|
1186 |
|
---|
1187 | - MJOptimize: For On/Off and Wobble optimization MJOptimize
|
---|
1188 | has been replaced by MJOptimizeCuts. To use MHThetaSq instead
|
---|
1189 | of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
|
---|
1190 | case MAlphaFitter is setup correctly. For On-Only optimization
|
---|
1191 | MJOptimize has been Replaced by MJOptimizeCuts, too. Call
|
---|
1192 | RunOn() instead of Run(). For energy estimation MJOptimize
|
---|
1193 | has been replaced by MJOptimizeEnergy
|
---|
1194 |
|
---|
1195 | - sponde: The input MC spectrum can now be weighted to fake a
|
---|
1196 | different spectrum. This is done via MMcSpectrumWeight. For
|
---|
1197 | more details see the class description and sponde.rc
|
---|
1198 |
|
---|
1199 | - sponde: The paremeter comparsion plots are not scaled by
|
---|
1200 | their entries anymore. Instead the MC plot is scaled by using
|
---|
1201 | the result spectrum of the analysis. If the input MC spectrum
|
---|
1202 | and the result spectrum has different slopes the absolut
|
---|
1203 | normalization is normally wrong.
|
---|
1204 |
|
---|
1205 |
|
---|
1206 |
|
---|
1207 | *** Version 0.9.2 (2005/05/20)
|
---|
1208 |
|
---|
1209 | - general: Changed the default paths for calibrated data and image
|
---|
1210 | files. (The implemented access to these files doesn't yet exist)
|
---|
1211 |
|
---|
1212 | - general: support for MRunIter has been removed from the job classes
|
---|
1213 | (use the setter functions of MSeqeunce instead)
|
---|
1214 |
|
---|
1215 | - general: ProcessFile has been renamed to Process in all job classes,
|
---|
1216 | because ProcessFile is missleading
|
---|
1217 |
|
---|
1218 | - general: The storage of the palette in MHCamera is now possible
|
---|
1219 |
|
---|
1220 | - general: new bits describing unsuitable and unreliable pixels have
|
---|
1221 | been introduced in MBadPixelsPix: kPreviouslyExcluded,
|
---|
1222 | kDeadPedestalRms, kFluctuatingArrivalTimes
|
---|
1223 |
|
---|
1224 | - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
|
---|
1225 | versions newer than V200404070
|
---|
1226 |
|
---|
1227 | - general: support for cc file versions newer than V200504130. Added
|
---|
1228 | support for active loads (MCameraActiveLoad) and central pixel
|
---|
1229 | (MCameraCentralPixel)
|
---|
1230 |
|
---|
1231 | - general: added new histograms for image parameters versus size
|
---|
1232 | (MHVsSize)
|
---|
1233 |
|
---|
1234 | - general: The eventloop now automatically calls PrintStatistics
|
---|
1235 |
|
---|
1236 | - Status Display: Improved support for printing:
|
---|
1237 | + A default can now be set in .rootrc (for more details see
|
---|
1238 | MStatusDisplay::PrintPS)
|
---|
1239 | + A print dialog is opened so that printer and command line
|
---|
1240 | can be canged
|
---|
1241 |
|
---|
1242 | - showlog: improved such that it handles different verbosity levels
|
---|
1243 | more accurate now. This mean you can suppress output when
|
---|
1244 | using showlog.
|
---|
1245 |
|
---|
1246 | - showplot: improved
|
---|
1247 | + The new graphics formats have been implemented
|
---|
1248 | (pdf, svg, png, jpg and xpm)
|
---|
1249 | + Implemented an interface for printing. Because you can change
|
---|
1250 | the printing command from the command line you can use all
|
---|
1251 | the nice postscript tool. To print a booklet for example call:
|
---|
1252 | showplot -b --print --print-cmd="cat %f" filename.root | lpr
|
---|
1253 | showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
|
---|
1254 | showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
|
---|
1255 |
|
---|
1256 | - callisto: fixed a bug in the recognition of the calibration bit
|
---|
1257 | pattern. Concerns only intensity calibration. (The strength of the
|
---|
1258 | intensity has been updated in some cases)
|
---|
1259 |
|
---|
1260 | - callisto: add a filter against PIN Diode events when running over
|
---|
1261 | calibration runs since some of the recent calibration runs have
|
---|
1262 | been taken with Pin Diode.
|
---|
1263 |
|
---|
1264 | - callisto: added support for the runs 39942, 39944, 44834, 39941,
|
---|
1265 | 39943, 44833 in the calibration (MCalibColorSet)
|
---|
1266 |
|
---|
1267 | - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
|
---|
1268 | been set to 1e-18 in callisto_Dec04_Jan05.rc
|
---|
1269 |
|
---|
1270 | - callisto: in callisto_Dec04Jan05.rc: set value for
|
---|
1271 | MJPedestalY2.MaxEvents from 2000 to 5000 to get better
|
---|
1272 | statistics for the calculation of the mean pulse time
|
---|
1273 | of the cosmisc
|
---|
1274 |
|
---|
1275 | - callisto: the charge limit in the calibration has been raised
|
---|
1276 | from 2.5 to 4.5
|
---|
1277 |
|
---|
1278 | - callisto: new setup read from callisto.rc
|
---|
1279 | + MCalibCalcFromPast.fNumEventsDump
|
---|
1280 | + MHCalibrationChargeCam.NumHiGainSaturationLimit
|
---|
1281 | + MHCalibrationChargeCam.NumLoGainSaturationLimit
|
---|
1282 |
|
---|
1283 | - callisto: MExtractTimeAndChargeSpline extractor:
|
---|
1284 | + The integration ranges were shifted by 0.2 FADC slices to the right.
|
---|
1285 | + unreliable handling of floating point values caused different
|
---|
1286 | results on different platform or with different compiler options:
|
---|
1287 | The new algorithm is numerically exact and more accurate because
|
---|
1288 | it doesn't calculate the integration position by multiple times
|
---|
1289 | adding the step-size (which results in numerical uncertanties
|
---|
1290 | exspecially if multiplied with large numbers)
|
---|
1291 | + A lot of fixes have been introduced which effects integrating the
|
---|
1292 | spline at the edges of the valid range. In this case any memory
|
---|
1293 | was randomly accessed. This behaviour can be tested replacing
|
---|
1294 | all MArrayF by TArrayF which perform a range check (but of course
|
---|
1295 | they are a lot slower)
|
---|
1296 | ! No result obtained with the Spline before can be trusted! Due to
|
---|
1297 | random memory access it might by completely random!
|
---|
1298 |
|
---|
1299 | - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
|
---|
1300 | + extraction range in the high gain to 4.
|
---|
1301 | + weights file to cosmics_weights46.dat
|
---|
1302 |
|
---|
1303 | - callisto:
|
---|
1304 | + introduce the check for fluctuating arrival times.
|
---|
1305 | + set charge limit to from 2.5 to 4.5
|
---|
1306 | + introduce asymmetric exclusion due to "deviating number of phes":
|
---|
1307 | Default: -9.0 +4.5
|
---|
1308 | + make deviating number of phes unsuitable (see David's findings).
|
---|
1309 |
|
---|
1310 | - callisto: fixed the display of unsuitable pixels. The old change
|
---|
1311 | to a real profile in MHCamera broke it.
|
---|
1312 |
|
---|
1313 | - callisto: The cosmics filter is used in MJCalibration now
|
---|
1314 | independant of the pulser color (formaly it was used only for
|
---|
1315 | CT1-pulser data). The threshold of number of max empty pixels
|
---|
1316 | has been raised from 2% to 5% in MJCalibration. The maximum
|
---|
1317 | fraction of rejected event is 50% otherwise the calibration has
|
---|
1318 | failed. The filter now ignores unsuitable pixels.
|
---|
1319 | Setup the filter from callisto.rc using "ContCosmics"
|
---|
1320 | (see MFCosmics::ReadEnv)
|
---|
1321 |
|
---|
1322 | - callisto: changed default for fgOffsetFromLogain back
|
---|
1323 | from -2.8 to -1.8 in digital filter.
|
---|
1324 |
|
---|
1325 | - callisto: for the common extractors
|
---|
1326 | + MExtractFixedWindow
|
---|
1327 | * MExtractTimeAndChargeSlidingWindow
|
---|
1328 | * MExtractTimeAndChargeSpline
|
---|
1329 | * MExtractTimeAndChargeDigitalFilter
|
---|
1330 | the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
|
---|
1331 | and fResolutionPerPheLoGain
|
---|
1332 |
|
---|
1333 | - callisto: Updated the hi-/lo-gain intercalibration constants
|
---|
1334 | hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
|
---|
1335 | hilocalib_df6.root
|
---|
1336 |
|
---|
1337 | - callisto: The default lo-gain extraction window for the
|
---|
1338 | MExtractTimeAndChargeSlidingWindow extractor has been increased
|
---|
1339 | from 6 to 8 to take the stretch of the pusle into account
|
---|
1340 |
|
---|
1341 | - callisto (!!!): fixed an important bug in the setting of the
|
---|
1342 | incoming pedestal pointer to the signal extractor extracting
|
---|
1343 | pedestals. This bug caused the pedestals not to be subtracted
|
---|
1344 | correctly in the calibration afterwards. The effect was about 10%
|
---|
1345 | too high conversion factors for the digital filter and the spline
|
---|
1346 | and more than 40% for the sliding window.
|
---|
1347 | The bug existed since end of February! (Markus G.)
|
---|
1348 |
|
---|
1349 | - star: added muon support to star. A new tab "MHMuonPar" is
|
---|
1350 | displayed. The lower right plot is an estimate of the point spread
|
---|
1351 | function. A reference value is displayed. To get the real PSF
|
---|
1352 | you must compare with MC. The setup for the muon analysis
|
---|
1353 | is done in star.rc. More informations can be found in
|
---|
1354 | MHSingleMuon and MHCalibParCalc
|
---|
1355 |
|
---|
1356 | - star: The weather data is now displayed in star
|
---|
1357 |
|
---|
1358 | - star: MEventRateCalc handles the calculation of the event rate more
|
---|
1359 | accurate now in case of the start of a new run inside a sequence
|
---|
1360 |
|
---|
1361 | - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
|
---|
1362 | from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
|
---|
1363 | changed only minimally
|
---|
1364 |
|
---|
1365 | - ganymed: (MJCut and MJOptimize) now displayes the number of
|
---|
1366 | excess events versus size. The energy estimation is done in
|
---|
1367 | MJSpectrum (sponde)
|
---|
1368 |
|
---|
1369 | - ganymed: got support for using other variables than Alpha, eg. Theta.
|
---|
1370 | Therefor you need a class deriving from MHAlpha which supports
|
---|
1371 | this variable (one is already existing: MHTheta, which is now the
|
---|
1372 | default in ganymed). It is setup through ganymed.rc
|
---|
1373 |
|
---|
1374 | - added a full featured spectrum program (sponde) which reads
|
---|
1375 | ganymed output and monte carlos and compiles a spectrum
|
---|
1376 |
|
---|
1377 |
|
---|
1378 |
|
---|
1379 | *** Version 0.9.1 (2005/04/14)
|
---|
1380 |
|
---|
1381 | - Fix bug on the arrival time reconstruction when using Digital
|
---|
1382 | Filter (in some marginal cases (10%) times were reconstructed shifted
|
---|
1383 | by 0.2 slices)
|
---|
1384 |
|
---|
1385 | - all executables now return 2 where in previous versions -1 has
|
---|
1386 | been returned (gave problems with shell-scripts)
|
---|
1387 |
|
---|
1388 | - the Hi-/Lo-Gain intercalibration for monte carlo files is now
|
---|
1389 | also done with a intercalibration input file
|
---|
1390 |
|
---|
1391 | - a bug in the time fine adjustment of the digital filter has been fixed
|
---|
1392 |
|
---|
1393 | - a lot of small fixes to calling TPad::Divide with a margin==0
|
---|
1394 |
|
---|
1395 | - MStatusDisplay now shows the memory usage
|
---|
1396 |
|
---|
1397 | - added a memory leak statistic after the eventloop
|
---|
1398 |
|
---|
1399 | - MHadronness replaced by MParameterD
|
---|
1400 |
|
---|
1401 | - MEnergyEst replaced by MParameterD
|
---|
1402 |
|
---|
1403 | - wobble mode can now be switched on from the data-set
|
---|
1404 |
|
---|
1405 | - switched on bad pixel detection for a pedestal level
|
---|
1406 | which is more than 5 times the variance
|
---|
1407 |
|
---|
1408 | - Fixed default paths to be correct for the new data center
|
---|
1409 |
|
---|
1410 | - Fixed handling of drive data. The pointing position in now
|
---|
1411 | copied to MPointingPos inside star for real and MC events
|
---|
1412 |
|
---|
1413 | - made sure, that the sequences in a dataset are sorted by
|
---|
1414 | their number to ensure the correct synchronization
|
---|
1415 |
|
---|
1416 | - added all resource files necessary to handle spline extraction
|
---|
1417 | of signal for the late 2004 and the early 2005 data
|
---|
1418 |
|
---|
1419 | - update the reference lines for the december data
|
---|
1420 |
|
---|
1421 | - changed default for fgHiGainFirst from 2 to 0 in spline extractor
|
---|
1422 | This is important for the Dec. and Jan. data where the calibration
|
---|
1423 | pulse position changes much.
|
---|
1424 |
|
---|
1425 | - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
|
---|
1426 | filter. This corrects only an defective extraction of the MC at
|
---|
1427 | low-gain signals lower than 90 phes.
|
---|
1428 |
|
---|
1429 | - fixed some slowdown in calibrating data with interleaved events from
|
---|
1430 | Jan and Dec. As a workaround made the pretty palette the default.
|
---|
1431 | The inverse Deep Blue Sea has a bug which slows down long calibration
|
---|
1432 | runs a lot.
|
---|
1433 |
|
---|
1434 | - implemented new values from new starguider report as defined
|
---|
1435 | in TDAS00-07 V7.1 (eg SkyBrighness)
|
---|
1436 |
|
---|
1437 | - Fixed the formerly wrong unit of azimuth and zenith angle deviation
|
---|
1438 | in starguider report (If you merpp the same reports with this version
|
---|
1439 | you'll get the correct units (arcmin) but a different result
|
---|
1440 | than with old versions (wrong units))
|
---|
1441 |
|
---|
1442 | - Now the status display can also write PNG, JPEG and XPM (other file
|
---|
1443 | formats are still unsupported by root)
|
---|
1444 |
|
---|
1445 | - added a lot of scripts and macros in directory datacenter used
|
---|
1446 | for automatic processing
|
---|
1447 |
|
---|
1448 |
|
---|
1449 |
|
---|
1450 | *** Version 0.9 (2005/03/23)
|
---|
1451 |
|
---|
1452 | - Calibration is now done autmatically into photo-electrons like
|
---|
1453 | decided by the Collaboration Board
|
---|
1454 |
|
---|
1455 | - Reference lines in the display can be read from resource file
|
---|
1456 |
|
---|
1457 | - Interlaced calibration events can be handled by callisto
|
---|
1458 |
|
---|
1459 | - Hi-Gain vs. Lo-Gain calibration constants can be calculated
|
---|
1460 | and applied in callisto.
|
---|
1461 |
|
---|
1462 | - class MJCalibTest can be called by callisto
|
---|
1463 |
|
---|
1464 | - callisto can now run with three data types: rawdata, rootdata, MC
|
---|
1465 |
|
---|
1466 | - added two classes mreport/MReportStarguider.cc and
|
---|
1467 | mreport/MReportStarguider.h for implementing starguider-data
|
---|
1468 |
|
---|
1469 | - the output of merpp-update now contains starguider information:
|
---|
1470 | MReportStarguider and MTimeStarguider
|
---|
1471 |
|
---|
1472 | - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
|
---|
1473 | values were lower than they should. This was more visible for high
|
---|
1474 | energy (Size) events.
|
---|
1475 |
|
---|
1476 | - Made MExtractTimeAndChargeDigitalFilter the default for callisto
|
---|
1477 |
|
---|
1478 | - added a new loop to callisto to support the correct extraction of
|
---|
1479 | the pedestal and pedestal rms through the signal extractor
|
---|
1480 |
|
---|
1481 | - added class to perform fourier tranformation of a hexagonal structure
|
---|
1482 | (MHexagonalFT)
|
---|
1483 |
|
---|
1484 | - added class to perform fourier tranformation of a hexagonal structure
|
---|
1485 | in a tasklist (MHexagonalFTCalc) example: hft.C
|
---|
1486 |
|
---|
1487 | - added class to enhance the MCerPhotEvt from the Magic camera geometry
|
---|
1488 | MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
|
---|
1489 | small pixels, example: extendcam.C
|
---|
1490 |
|
---|
1491 | - added possibility to write data to memory (TTree) using MWriteRootFile
|
---|
1492 |
|
---|
1493 | - added possibility to read a TTree stored only in memory by MReadTree
|
---|
1494 |
|
---|
1495 | - new classes to deal with the interleaved calibration events:
|
---|
1496 | MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
|
---|
1497 |
|
---|
1498 | - implemented filters to callisto to skip calibration events
|
---|
1499 |
|
---|
1500 | - changed callisto to calculate three kinds of pedestals and pedestal rms:
|
---|
1501 | + fundamental pedestal (MPedPhotFundamental): extracted directly from
|
---|
1502 | the slices by statistics
|
---|
1503 | + pedestal from extractor (MPedPhotFromExtractor): extracted with the
|
---|
1504 | signal extractor without randomization
|
---|
1505 | + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
|
---|
1506 | with the signal extractor with randomization (extraction window is
|
---|
1507 | randomly fixed)
|
---|
1508 | The three kind of pedestal is not yet implemented (for speed reasons) as
|
---|
1509 | long as nobody really needs it:
|
---|
1510 | + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
|
---|
1511 | extracted with the signal extractor with randomization
|
---|
1512 |
|
---|
1513 | - callisto now finds the pulse position in the data automatically
|
---|
1514 |
|
---|
1515 | - implemented data reduction in calibrated data by reducing the precision
|
---|
1516 | of the stored floating point values (pedestal, rms and signal) to
|
---|
1517 | roughly 0.5%
|
---|
1518 |
|
---|
1519 | - fixed showplot to make file format conversion (eg. converting a
|
---|
1520 | status display stored in a root file into a postscript file) in
|
---|
1521 | batch mode possible:
|
---|
1522 | showplot -b --save-as-ps[=outfile.ps] infile.root
|
---|
1523 |
|
---|
1524 | - Allow class names as part of filter rules, eg
|
---|
1525 | (MFSupercuts) && (MHillas.fSize>100)
|
---|
1526 |
|
---|
1527 | - fixed a lot of stuff to allow all programs to process MonteCarlo
|
---|
1528 | camera files.
|
---|
1529 |
|
---|
1530 | - enhanced possibility to debug reading of resource file
|
---|
1531 |
|
---|
1532 | - MDataChain should handle priorities of operator more
|
---|
1533 | accurate now
|
---|
1534 |
|
---|
1535 | - completely revised the container in which the signal is stored
|
---|
1536 | MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
|
---|
1537 | * the new implementation is faster and
|
---|
1538 | * needs less storage space
|
---|
1539 |
|
---|
1540 | - FIRST version which can process Monte Carlos through the
|
---|
1541 | whole chain of programs (callisto, star, etc)
|
---|
1542 |
|
---|
1543 | - implemented new image parameters for the border length of
|
---|
1544 | the shower image (MNewImagePar2)
|
---|
1545 |
|
---|
1546 | - implemented wobble-mode in ganymed
|
---|
1547 |
|
---|
1548 | - new class (MJOptimize) taking care of all optimization processes
|
---|
1549 |
|
---|
1550 |
|
---|
1551 |
|
---|
1552 | *** Version 0.8.6 (2004/10/05)
|
---|
1553 |
|
---|
1554 | - New combined signal and time extractor
|
---|
1555 | MExtractTimeAndChargeDigitalFilter
|
---|
1556 |
|
---|
1557 | - The Report for the trigger section in the CC run summary has been
|
---|
1558 | updated, and now the IPRs (Individual Pixel Rates) are available.
|
---|
1559 |
|
---|
1560 | - new macros for database interaction: filldotrun.C, filldotrbk.C
|
---|
1561 |
|
---|
1562 | - added new program which can convert colored output which was redirected
|
---|
1563 | into a file back into colored text (for example to display it with
|
---|
1564 | more): showlog
|
---|
1565 |
|
---|
1566 | - added new program to display an MStatusArray of plots (stored with
|
---|
1567 | MStatusDisplay) from a file: showplot
|
---|
1568 |
|
---|
1569 | - Added support for Sequences (MSequence). Sequences are blocks of run
|
---|
1570 | files containing the same calibration and belonging to the same
|
---|
1571 | source
|
---|
1572 |
|
---|
1573 | - Added a new task (MTaskEnv) which can be used in setup files to switch
|
---|
1574 | between different tasks (for example to choose a signal extractor)
|
---|
1575 |
|
---|
1576 | - Implemented automatic file splitting in MWriteRootFile
|
---|
1577 |
|
---|
1578 | - After image cleaning an island index is assigned to all used pixels.
|
---|
1579 | The index corresponds to the order of the islands in size.
|
---|
1580 |
|
---|
1581 | - added a cleaning which takes signal height _and_ arrival time into
|
---|
1582 | account: probability cleaning (for more details see MImgCleanStd)
|
---|
1583 |
|
---|
1584 | - added a cleaning which takes takes the absolute number of photons
|
---|
1585 | times the area ratio as cleaning level
|
---|
1586 | (for more details see MImgCleanStd)
|
---|
1587 |
|
---|
1588 | - Changed calculation of image parameters such, that it can be done
|
---|
1589 | for all used pixels or the pixels with a defined island index only
|
---|
1590 |
|
---|
1591 | - implemented new image parameters displaying the number of islands,
|
---|
1592 | saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
|
---|
1593 |
|
---|
1594 | - event display in executable changed to support also calibrated files
|
---|
1595 | (done with MJCalibrateSignal)
|
---|
1596 |
|
---|
1597 | - added program doing the calibration and the signal extraction
|
---|
1598 | and signal calibration: callisto Most part of the setup is done
|
---|
1599 | by a resource file: callisto.rc
|
---|
1600 |
|
---|
1601 | - implemented support for pixels with negative IDs (Raw file format
|
---|
1602 | version 4)
|
---|
1603 |
|
---|
1604 | - implemented an new option in merpp (--auto-time) to get the time
|
---|
1605 | range for cc and/or caco data from the run header of the raw data
|
---|
1606 |
|
---|
1607 | - New star-program (star and MJStar). Taking calibrated data from
|
---|
1608 | callisto/MJCalibrateSignal as input. The setup is done through
|
---|
1609 | a resource file: star.rc
|
---|
1610 |
|
---|
1611 | - Added possibility to setup the eventloop in the mars-executable
|
---|
1612 | Camera Display by a resource file: mars.rc
|
---|
1613 |
|
---|
1614 | - The the mars-executable Camera Display can now also read
|
---|
1615 | calibrated data files written by callisto/MJCalibrateSignal
|
---|
1616 |
|
---|
1617 | - Added a new class which can calculate the source position in
|
---|
1618 | the camera from a pointing model known to be correct and
|
---|
1619 | the pointing model used for observations (MSrcPosFromModel)
|
---|
1620 |
|
---|
1621 | - added a new version of the class calculating the effective on-time
|
---|
1622 | MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
|
---|
1623 | MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
|
---|
1624 | MHTimeDiffTheta.
|
---|
1625 |
|
---|
1626 | - added the possibility to count how often a signal is above (or
|
---|
1627 | below) a certain threshold in MHCamEvent and MHCamEventRot (this
|
---|
1628 | can replace MHTriggerLvl0)
|
---|
1629 |
|
---|
1630 | - added ore convinient ways to set the axis-titles of your histograms
|
---|
1631 | in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
|
---|
1632 | MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
|
---|
1633 |
|
---|
1634 |
|
---|
1635 |
|
---|
1636 | *** Version 0.8.5 (2004/08/06)
|
---|
1637 |
|
---|
1638 | - new Signal Extractors: MExtractFixedWindowSpline
|
---|
1639 | and MExtractAmplitudeSpline
|
---|
1640 |
|
---|
1641 | - implementes interleave in merpp to be able to merpp parts of a file
|
---|
1642 |
|
---|
1643 | - implemented force-functionality to merpp
|
---|
1644 |
|
---|
1645 | - star display to display star catalogs (MAstroCatalog)
|
---|
1646 |
|
---|
1647 | - star display to 'mirror' stars to the camera (MAstroCamera)
|
---|
1648 |
|
---|
1649 | - implemented a new cleaning option which allows cleaning scaled with
|
---|
1650 | the real ratio of the rms depending on the pixel size, not only the
|
---|
1651 | square root of the pixelsize (MImgCleanStd, MCameraData)
|
---|
1652 |
|
---|
1653 | - removed obsolete MBlind* classes
|
---|
1654 |
|
---|
1655 | - Signal extractor taking the AB flag into account implemented (this makes
|
---|
1656 | an odd number of slices for signal extraction possible
|
---|
1657 | (MExtractSignalABcorr)
|
---|
1658 |
|
---|
1659 | - implemented a class extracting the pedestal from the raw-data (events)
|
---|
1660 | itself using empty lo-gain (MpedCalcFromLoGain)
|
---|
1661 |
|
---|
1662 | - Added mean values to MPedPhotCam
|
---|
1663 |
|
---|
1664 | - Added Makefile for Darwin (this OS is NOT officially supported!)
|
---|
1665 |
|
---|
1666 |
|
---|
1667 |
|
---|
1668 | *** Version 0.8.4 (2004/04/19)
|
---|
1669 |
|
---|
1670 | - new fast arrival time extractor using cubic splines:
|
---|
1671 | MExtractTimeFastSpline
|
---|
1672 |
|
---|
1673 | - implementes multi-argument support in MDataChain
|
---|
1674 | ("pow(a, b)")
|
---|
1675 |
|
---|
1676 | - implemented double reference support in MDataChain
|
---|
1677 | ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
|
---|
1678 |
|
---|
1679 | - added support in MF for expressiond like
|
---|
1680 | "MHillas.fWidth<2*<MHillas.fLength"
|
---|
1681 |
|
---|
1682 | - MDataChain is now able to support variables like [0], [1], ...
|
---|
1683 | which can be used in fit functions as parameters. The interface
|
---|
1684 | is implemented through the new virtual function
|
---|
1685 | MParContainer::SetVariables
|
---|
1686 |
|
---|
1687 | - added new class MArrivalTimeCam/MArrivalTimePix:
|
---|
1688 | Storage containers to hold the ArrivalTime of the camera/pixel
|
---|
1689 |
|
---|
1690 | - added new classes for the calibration of relative arrival times:
|
---|
1691 | MCalibrationRelTimePix and MCalibrationRelTimeCam
|
---|
1692 |
|
---|
1693 | - added new classes to extract the signal of the blind pixel and the
|
---|
1694 | PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
|
---|
1695 |
|
---|
1696 | - added new classes for the bad-pixels treatment (MBadPixels*)
|
---|
1697 | which are more powerfull than the old ones (MBlindPixel*)
|
---|
1698 | and will replace them.
|
---|
1699 |
|
---|
1700 | - added filter against cosmics: MFCosmics
|
---|
1701 |
|
---|
1702 | - added new class MArrivalTimeCalc2:
|
---|
1703 | Calculates the arrival time as the signal weighted mean of the time
|
---|
1704 | slices in the maximum window
|
---|
1705 |
|
---|
1706 | - added a new macro call pointspreadfucntion.C that fits with a 2D
|
---|
1707 | gaussian the DC spot for an star. It gives you the RMS of
|
---|
1708 | the PSF and the center of the star, very useful for misspointing
|
---|
1709 | studies.
|
---|
1710 |
|
---|
1711 | - added support for multi-telescope camera files. Added classes
|
---|
1712 | MStereoCalc and MStereoPar, classes to calculate and store shower
|
---|
1713 | parameters calculated from the data of two telescopes, for the MC
|
---|
1714 | studies regarding the MAGIC clone.
|
---|
1715 |
|
---|
1716 | - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
|
---|
1717 | MC data calibrated in photons instead of ADC counts.
|
---|
1718 |
|
---|
1719 | - added three macros to show the calibration and analysis chain of
|
---|
1720 | MC data. The macro starmc.C does both calibration and analysis, producing
|
---|
1721 | an output containing Hillas parameters for each event. The macro
|
---|
1722 | mccalibrate.C does just the calibration and writes out a file containing
|
---|
1723 | pixel information in photons instead of FADC data. The macro starmc2.C
|
---|
1724 | reads in such a file and produces an output with Hillas parameters.
|
---|
1725 |
|
---|
1726 | - added MPedPhotCalc to compute pedestals in units of photons, see
|
---|
1727 | macro pedphotcalc.C
|
---|
1728 |
|
---|
1729 | - added all class to perform the calibration, see macro calibration.C
|
---|
1730 |
|
---|
1731 | - added class MFFT to perform Fast Fourier Transforms
|
---|
1732 |
|
---|
1733 | - added class MSimulatedAnnealing to perform simulated annealing
|
---|
1734 | minimizations
|
---|
1735 |
|
---|
1736 | - added new macro bootcampstandardanalysis.C which holds the skeleton
|
---|
1737 | of the analysis chain discussed in the december bootcamp.
|
---|
1738 |
|
---|
1739 | - added support for DAQ raw data file format V2
|
---|
1740 |
|
---|
1741 | - implemented an arbitrary time stamp for the events from raw-data
|
---|
1742 | files with file version<3. It is calculated from the run number,
|
---|
1743 | the date of start and the FADC clock tick from the first module
|
---|
1744 |
|
---|
1745 | - implemented the correct decoding of the event time-stamp
|
---|
1746 | coming from the DAQ for raw-data files with file-version>2
|
---|
1747 |
|
---|
1748 | - added a new classes storing the pedestals in units of photons:
|
---|
1749 | MPedPhotPix, MPedPhotCam
|
---|
1750 |
|
---|
1751 | - added support for DC current files from the camera control
|
---|
1752 |
|
---|
1753 | - added support for start- and stop-time when merpping report files
|
---|
1754 |
|
---|
1755 | - added MReportCC storing the weather data from the CC-REPORT
|
---|
1756 |
|
---|
1757 | - added class to fill trainings and test matrices (MTFillMatrix)
|
---|
1758 |
|
---|
1759 | - added a filter performing a software trigger (MFSoftwareTrigger)
|
---|
1760 |
|
---|
1761 | - Added classes to perform parts of the standard analysis (Jobs):
|
---|
1762 | + MJPedestals
|
---|
1763 | + MJCalibration
|
---|
1764 | + MJExtractSignal
|
---|
1765 | Note: All of them are preliminary!
|
---|
1766 |
|
---|
1767 | - Added Iterator to iterate over files giving only the run-number
|
---|
1768 |
|
---|
1769 | - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
|
---|
1770 | the evolution of a sector vs time
|
---|
1771 |
|
---|
1772 |
|
---|
1773 |
|
---|
1774 | *** Version 0.8.3 (2003/12/05)
|
---|
1775 |
|
---|
1776 | - adapted Random Forest classes to allow the use with MC
|
---|
1777 | multi-telescope files which can be produced with the coming
|
---|
1778 | camera version 0.7.
|
---|
1779 |
|
---|
1780 | - added classes to read and interprete central control report files
|
---|
1781 | (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
|
---|
1782 |
|
---|
1783 | - enhanced merpp (the executable) to support .raw and .rep files.
|
---|
1784 |
|
---|
1785 | - added classes for light calibration (MCalibration* and
|
---|
1786 | MHCalibration*) by Markus Gaug. Further work has to be and will
|
---|
1787 | be done soon.
|
---|
1788 |
|
---|
1789 | - Added a preliminary 'synchronizer' (MReadReports) which will
|
---|
1790 | replace MReadMarsFile as soon as it is finished.
|
---|
1791 |
|
---|
1792 | - Added a tutorial macro demonstrating how report files are merpped
|
---|
1793 | and how they can be read from the root file in the correct order
|
---|
1794 | of time (readrep.C)
|
---|
1795 |
|
---|
1796 | - Added a generalized histogram (similar to MH3) called MVsTime
|
---|
1797 | which allows to plot variables (or rules - MDataChain - of
|
---|
1798 | variables) vs time. For an example have a look at tempvstime.C.
|
---|
1799 |
|
---|
1800 | - Changed the name of the event trees:
|
---|
1801 | + Events --> Events
|
---|
1802 | + PedEvents --> Pedestals
|
---|
1803 | + CalEvents --> Calibration
|
---|
1804 |
|
---|
1805 | - changed name of MTime in the event trees from MRawEvtTime to MTime
|
---|
1806 |
|
---|
1807 | - added displaying the sector indices to the mars event display
|
---|
1808 |
|
---|
1809 | - Magic Online Analysis (MOnA) implemented in a first version
|
---|
1810 | (see mona.cc, MOnlineDump and MOnlineDisplay)
|
---|
1811 |
|
---|
1812 | - added classes to calculate event rate
|
---|
1813 | (preliminary: MEventRateCalc, MEventRate)
|
---|
1814 |
|
---|
1815 | - added new executable 'readdaq' to read *.raw files from the DAQ directly
|
---|
1816 |
|
---|
1817 | - added classes dealing with the telescope pointing position (MPointing*)
|
---|
1818 |
|
---|
1819 | - implemented the 'final' Mars time stamp based on some experiences with
|
---|
1820 | the new 'Synchonizer'
|
---|
1821 |
|
---|
1822 |
|
---|
1823 |
|
---|
1824 | *** Version 0.8.2 (2003/11/10)
|
---|
1825 |
|
---|
1826 | - accelerated standard analysis by a factor of 6-8 ...
|
---|
1827 | + doing precalculations in MGeomCam for the pixel area ratio
|
---|
1828 | + creating a look up table for the single pixels in MCerPhotEvt
|
---|
1829 |
|
---|
1830 | - added task to calculates weights in case you want to 'change'
|
---|
1831 | the energy spectrum of a monte carlo file
|
---|
1832 | (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
|
---|
1833 |
|
---|
1834 | - added a new executable star which implements the
|
---|
1835 | star.C macro as precompiled executable. Currently a flexible
|
---|
1836 | setup is not possible, but a 'input card' setup will follow.
|
---|
1837 |
|
---|
1838 | - Starting to implement Multi-Telescope-Support based on the
|
---|
1839 | upcomming camera version 0.7. The base for a general support
|
---|
1840 | is implemented and the star-functionality is proven to work.
|
---|
1841 |
|
---|
1842 | - Replaced Event-Display in and Camera-Display in the Mars GUI
|
---|
1843 | executable by a more convinient display base on MStatusDisplay.
|
---|
1844 |
|
---|
1845 | - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
|
---|
1846 |
|
---|
1847 |
|
---|
1848 |
|
---|
1849 | *** Version 0.8.1 (2003/10/20)
|
---|
1850 |
|
---|
1851 | - added signal subtraction for pure on data by means of fitting
|
---|
1852 | the background in the off region or by performing a combined
|
---|
1853 | signal/background fit. Provides necessary histograms for
|
---|
1854 | obtaining energy spectra and a light curve.
|
---|
1855 |
|
---|
1856 | - added classes to perform and study the selection of the
|
---|
1857 | 2nd Level Trigger on MC data (example in triglvl2.C macro)
|
---|
1858 |
|
---|
1859 | - added pedestal calculation
|
---|
1860 |
|
---|
1861 | - implemented "democratic cleaning" (tail cut value proportional
|
---|
1862 | to pixel area) according to Wolfgang's suggestion.
|
---|
1863 |
|
---|
1864 | - added Sigmabar treatment (calculation and basic histogramming)
|
---|
1865 |
|
---|
1866 | - added basic routines to apply padding
|
---|
1867 |
|
---|
1868 | - added first implementation of MARS-based source visibility plotter
|
---|
1869 | (needs to be linked against slalib, preliminary version)
|
---|
1870 |
|
---|
1871 | - enhanced functionality of data chains: random numbers, conversion
|
---|
1872 | functions and access to MHMatrix objects
|
---|
1873 |
|
---|
1874 | - fixed some bugs in the CT1 Preproc file reader, which gave wrong
|
---|
1875 | numbers under certain circumstances (runs with 0 events included)
|
---|
1876 |
|
---|
1877 | - fixed a bug in the general filter MF (didn't work on some systems
|
---|
1878 | at all)
|
---|
1879 |
|
---|
1880 | - fixed a bug in chaining files, which caused the analysis to crash or
|
---|
1881 | ignore files
|
---|
1882 |
|
---|
1883 | - implemented more geometry classes describing the parameters used
|
---|
1884 | to simulate the PMT camera
|
---|
1885 |
|
---|
1886 | - added new Monte Carlo classes containing the setup of the different
|
---|
1887 | programs in the MC chain.
|
---|
1888 |
|
---|
1889 | - added a (preliminary) general task to evaluate chi-square of a given
|
---|
1890 | parameter in an eventloop.
|
---|
1891 |
|
---|
1892 | - first implementation of a container describing the observatory
|
---|
1893 | location (Long, Lat, etc)
|
---|
1894 |
|
---|
1895 | - added Random Forest - method for g/h-separation
|
---|
1896 |
|
---|
1897 | - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
|
---|
1898 | (this means, that it is compiling, but not yet fully tested)
|
---|
1899 |
|
---|
1900 | - added a new status display which can show the present status
|
---|
1901 | of histograms while an eventloop is running (MStatusDisplay,
|
---|
1902 | an example can be found at status.C)
|
---|
1903 |
|
---|
1904 | - reorganized directories:
|
---|
1905 | classes describing the image --> mimage
|
---|
1906 | classes containing Monte Carlo Histograms --> mhistmc
|
---|
1907 | classes for Random Forest method --> mranforest
|
---|
1908 |
|
---|
1909 | - added (event-)weights to fill histograms
|
---|
1910 |
|
---|
1911 | - colors in logging output to screen
|
---|
1912 |
|
---|
1913 | - changes to the Image Parameter declaration:
|
---|
1914 | + moved fConc, fConc1 from MHillasSrc to MNewImagePar
|
---|
1915 | + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
|
---|
1916 | + MHillasExt now derives from MParContainer instead of MHillas
|
---|
1917 | --> Files written with the old definition are more or less unreadable
|
---|
1918 |
|
---|
1919 | - reading of reflector files
|
---|
1920 |
|
---|
1921 | - display data from reflector files in the camera
|
---|
1922 |
|
---|
1923 | - implemented currents (and display them in the camera)
|
---|
1924 |
|
---|
1925 | - logarithmic scale in camera
|
---|
1926 |
|
---|
1927 | - added class to iterate through directory contents (MDirIter)
|
---|
1928 |
|
---|
1929 |
|
---|
1930 |
|
---|
1931 | *** Version 0.8 (2002/11/18)
|
---|
1932 |
|
---|
1933 | - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
|
---|
1934 |
|
---|
1935 | - corrected 48(!) wrong entries in the Next Neighbor table of the
|
---|
1936 | Magic Camera (all in the inner part of the outer ring, mostly
|
---|
1937 | missing a single NN)
|
---|
1938 |
|
---|
1939 | - Fixed a bug in the table describing the Next Neighbours of the
|
---|
1940 | CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
|
---|
1941 | have any neighbour)
|
---|
1942 |
|
---|
1943 | - changed trigrate.C: now it calculates the pure NSB triggers from
|
---|
1944 | a camera file (generated with no showers), so there is no need
|
---|
1945 | to introduce them by hand in the BgR array (for more details
|
---|
1946 | please ask Abelardo)
|
---|
1947 |
|
---|
1948 | - added MHHadronness (and MHadronness) as a general facility to evaluate
|
---|
1949 | the quality of a gamma-hadron seperation method
|
---|
1950 |
|
---|
1951 | - changed MWriteAsciiFile to accept rules (MDataChain)
|
---|
1952 |
|
---|
1953 | - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
|
---|
1954 | must be replaced by calles to MWriteAsciiFile::AddColumn and
|
---|
1955 | MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
|
---|
1956 | changed.
|
---|
1957 |
|
---|
1958 | - Implemented generalized event-matrices (one row per event)
|
---|
1959 | (MHMatrix)
|
---|
1960 |
|
---|
1961 | - implemented the one dimensional composite probabilities
|
---|
1962 | (MHCompProb, MCompProbCalc, comprob.C)
|
---|
1963 |
|
---|
1964 | - implemented the Multidimensional Distances (Next Neighbours, Kernel)
|
---|
1965 | (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
|
---|
1966 |
|
---|
1967 | - Added a camera display displaying the pixel numbers to the
|
---|
1968 | event display gui.
|
---|
1969 |
|
---|
1970 | - Added Monte Carlo Informations to event display gui
|
---|
1971 |
|
---|
1972 | - Changed the camera display to display the pixel numbering
|
---|
1973 |
|
---|
1974 | - Added three buttons to the camera display to change the palette
|
---|
1975 |
|
---|
1976 | - Added the number of used and core pixels after image cleaning
|
---|
1977 | to MHillas
|
---|
1978 |
|
---|
1979 | - Changed the algorithm used in MHillas according to TDAS 02-03
|
---|
1980 |
|
---|
1981 | - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
|
---|
1982 |
|
---|
1983 | - Changed the algorithm used in MHillasSrc according to TDAS 02-03
|
---|
1984 |
|
---|
1985 | - Added fCosDeltaAlpha to MHillasSrc
|
---|
1986 |
|
---|
1987 | - The numbers of photons used to calculate fConc and fConc1 in
|
---|
1988 | MHillasExt are now scaled with the pixel size, so that one get
|
---|
1989 | a four times smaller value for the bigger pixels in the outer ring.
|
---|
1990 |
|
---|
1991 | - added new task to smooth the camera contents (MCameraSmooth)
|
---|
1992 |
|
---|
1993 | - added possibility to use interpolated pixel values for blind pixels
|
---|
1994 | instead of removing it completely from the analysis
|
---|
1995 |
|
---|
1996 | - Implemented the possibility to save the whole eventloop with
|
---|
1997 | its setup to a file. This information can be read and from
|
---|
1998 | it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
|
---|
1999 | and MEvtLoop::MakeMacro. If you find something not working, please
|
---|
2000 | report - this stuff is still in a beta phase.
|
---|
2001 |
|
---|
2002 | - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
|
---|
2003 | file having crab starfield, but also for all following files - fixed
|
---|
2004 |
|
---|
2005 | - MTaskList::PrintStatistics can now be instructud to print also the
|
---|
2006 | title, too: use PrintStatistics(0, kTRUE)
|
---|
2007 |
|
---|
2008 | - Changed the image cleaning so that pixels with to many 'used'
|
---|
2009 | neighbors are left used (to get rid of 'holes' in events)
|
---|
2010 |
|
---|
2011 | - Introduced more output to the camera displays
|
---|
2012 |
|
---|
2013 | - Added an array of histograms (eg one hist per run), MHArray
|
---|
2014 |
|
---|
2015 | - Added a _preliminary_ version of the reader for CT1 PreProc files
|
---|
2016 | (MCT1ReadPreProc)
|
---|
2017 |
|
---|
2018 | - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
|
---|
2019 | (thanks to Raquel)
|
---|
2020 |
|
---|
2021 | - added the first energy estimator (MEnergyEstParam, estimate.C,
|
---|
2022 | estfit.C) using a parametrization
|
---|
2023 |
|
---|
2024 | - Added some new Monte Carlo paremeter containers used to store
|
---|
2025 | setup information from the MC chain (MMcConfigRunHeader,
|
---|
2026 | MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
|
---|
2027 |
|
---|
2028 |
|
---|
2029 |
|
---|
2030 | *** Version 0.7 (2002/04/30)
|
---|
2031 |
|
---|
2032 | - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
|
---|
2033 | the pedestal mean value was saved incorrectly. For files from
|
---|
2034 | this versions we substract 0.5 from the pedestal mean.
|
---|
2035 | WARNING: This may effect your results, so don't wonder...
|
---|
2036 |
|
---|
2037 | - First implementation of an algorithm using only triggered events
|
---|
2038 | for the collection area calculation
|
---|
2039 |
|
---|
2040 | - Ascii Output can now also be used for parameter containers which
|
---|
2041 | doesn't overload MParCointainer::AsciiWrite
|
---|
2042 |
|
---|
2043 | - The Ascii Output is now also capable of writing single data members
|
---|
2044 | of one container
|
---|
2045 |
|
---|
2046 | - You are now able to change the order of the values written to the
|
---|
2047 | ascii file
|
---|
2048 |
|
---|
2049 | - You can now specify a conversion factor for each data member written
|
---|
2050 | to an ascii file. This may be usefull to change the units of the
|
---|
2051 | data member (eg. degrees instead of millimeters in case of the
|
---|
2052 | hillas parameters)
|
---|
2053 |
|
---|
2054 | - Replaced old MHillas by a new structure which allows you to extend
|
---|
2055 | the parameters stored in MHillas very easily:
|
---|
2056 | see MHillas and MHillasExt
|
---|
2057 |
|
---|
2058 | - Added classes to handle source dependancy of image parameters:
|
---|
2059 | see MHillasSrc
|
---|
2060 |
|
---|
2061 | - Added container (MBinning) to have a standard input for the binning
|
---|
2062 | in different histograms (eg. the Energy bins should be the same in
|
---|
2063 | all histograms)
|
---|
2064 |
|
---|
2065 | - Changed Hillas histograms from mm to deg
|
---|
2066 |
|
---|
2067 | - Added the flexible binning to the hillas histograms
|
---|
2068 |
|
---|
2069 | - Added a filter for the alpha parameter (MFAlpha)
|
---|
2070 |
|
---|
2071 | - It is now possible to write single data members of a class object to
|
---|
2072 | an output stream instead of the whole container only
|
---|
2073 |
|
---|
2074 | - Added a generalized filter for a data member:
|
---|
2075 | MFDataMember filter("MHillas.fWidth", '<', 0.5);
|
---|
2076 |
|
---|
2077 | - Added a generalized Filter parser for more difficult filter rules
|
---|
2078 | MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
|
---|
2079 |
|
---|
2080 | - Added new Monte Carlo histograms:
|
---|
2081 | MHMcEnergyImpact and MHMcEfficiency
|
---|
2082 |
|
---|
2083 | - Added many new histograms needed for the flux calculation.
|
---|
2084 |
|
---|
2085 | - Added a generalized histograms which can fill and show up to three
|
---|
2086 | data members in either a one-, two- or three-dimensional histogram, eg:
|
---|
2087 | MH3 mh3("MHillas.fWidth", "MHillas.fLength");
|
---|
2088 |
|
---|
2089 | - Added:
|
---|
2090 | * calculation of <Theta> as a function of Theta (MHThetabarTheta)
|
---|
2091 | * calculation of <Theta> as a function of time (MHThetabarTime)
|
---|
2092 | they are needed in the flux calculation in
|
---|
2093 | order to select for a given bin in Theta (or time) the appropriate
|
---|
2094 | effective collection area, which is assumed to be given as a function
|
---|
2095 | of Theta and the true energy
|
---|
2096 |
|
---|
2097 | - Added calculation of the migration matrix in the energy
|
---|
2098 | (MHMcEnergyMigration):
|
---|
2099 | the migration matrix describes the migration from the true (E_true)
|
---|
2100 | to the estimated energy (E_est); it is needed to determine the
|
---|
2101 | distribution of E_true from the measured distribution of E_est
|
---|
2102 | by unfolding
|
---|
2103 |
|
---|
2104 | - changed the color palette in the camera display to DeapSea.
|
---|
2105 |
|
---|
2106 |
|
---|
2107 |
|
---|
2108 | *** Version 0.6 (2002/01/15)
|
---|
2109 |
|
---|
2110 | - Introduce the option of disable pixels (MBlindPixels and
|
---|
2111 | MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
|
---|
2112 | able to deal with Star Field NSB.
|
---|
2113 |
|
---|
2114 | - Fixed a bug in the pedestals substraction
|
---|
2115 |
|
---|
2116 | - Introduced verbosity levels
|
---|
2117 |
|
---|
2118 | - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
|
---|
2119 |
|
---|
2120 | - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
|
---|
2121 | work correctly (thanks to Abelardo)
|
---|
2122 |
|
---|
2123 | - Introduced correct treatment of the diffuse Night Sky Background
|
---|
2124 | and NSB (MMcPedestalNSB)
|
---|
2125 |
|
---|
2126 | - Corrected treatment of the electronic noise (MMcPedestalCopy)
|
---|
2127 |
|
---|
2128 | - Introduced MMcRunHeaders which contains monte carlo run informations
|
---|
2129 |
|
---|
2130 | - Added a 'Print'-Task (MPrint) which calls the Print function
|
---|
2131 | of a parameter container for each event
|
---|
2132 |
|
---|
2133 | - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
|
---|
2134 |
|
---|
2135 | - changes to be more efficient with root 3.02/06
|
---|
2136 |
|
---|
2137 | - root 3.02/06 fixes:
|
---|
2138 | + the memory leak when reading MRawEvtData
|
---|
2139 | + loosing more time than necessary to update the progress bar
|
---|
2140 |
|
---|
2141 | - MWriteAsciiFile is now capable of writing more than one container
|
---|
2142 | in a line. For example: To be able to write Monte Carlo and
|
---|
2143 | Hillas values (energy and alpha) in one line.
|
---|
2144 |
|
---|
2145 |
|
---|
2146 |
|
---|
2147 | *** Version 0.5 (2001/11/06)
|
---|
2148 |
|
---|
2149 | - Added new GUI functionality (Analysis)
|
---|
2150 |
|
---|
2151 | - Added a camera display to be able to display events in the camera
|
---|
2152 | together with the calculated hillas ellipse
|
---|
2153 |
|
---|
2154 | - Added a 'Clone'-Task (MClone) which can clone a parameter container
|
---|
2155 | object at any state of the analysis, so that the output are several
|
---|
2156 | states
|
---|
2157 |
|
---|
2158 | - Fixed a bug in the collection area error calculation
|
---|
2159 | (Thanks to Ciro and Abelardo)
|
---|
2160 |
|
---|
2161 | - Fixed a bug which causes merpp to crash in some environments
|
---|
2162 |
|
---|
2163 | - Implemented auto enabling scheme for Branches to speed up reading
|
---|
2164 | a lot (see MReadTree and MTask)
|
---|
2165 |
|
---|
2166 | - Fixed a bug in the Histogram classes which caused histograms to
|
---|
2167 | be written to a file by MWriteRootFile without request
|
---|
2168 |
|
---|
2169 | - changed the object I/O from the old stylish root I/O to the new
|
---|
2170 | 'auto evolution scheme' This was done only for classes which are not
|
---|
2171 | yet used in Monte Carlo files, so that these files are still readable.
|
---|
2172 |
|
---|
2173 | - Added support for a progress bar in MEvtLoop and MReadTree
|
---|
2174 | (see the Analysis Window in Mars for an example)
|
---|
2175 |
|
---|
2176 | - Fixed a bug in the package creation which disturbed the conversion
|
---|
2177 | between a mars version unpacked from a tar file and the repository.
|
---|
2178 |
|
---|
2179 | - Changed the code to writer merpped (converted into root format)
|
---|
2180 | raw files, to get faster (around 10%)
|
---|
2181 |
|
---|
2182 |
|
---|
2183 |
|
---|
2184 | *** Version 0.4 (2001/09/20)
|
---|
2185 |
|
---|
2186 | - This release is made to compile on a root version >= 3.00
|
---|
2187 |
|
---|
2188 | - Fixed a bug which causes MReadTree to read the first file only
|
---|
2189 |
|
---|
2190 | - Added a task to compute the trigger rate (MMcTriggerRateCalc)
|
---|
2191 |
|
---|
2192 | - Added a task to write a container to an Ascii file (MWriteAsciiFile)
|
---|
2193 |
|
---|
2194 | - Added a task to write several container to a root file (MWriteRootFile)
|
---|
2195 |
|
---|
2196 | - Added calculation of the Enegry Threshold (MMcThresholdCalc)
|
---|
2197 |
|
---|
2198 | - Added calculation of the collection area (MMcCollectionAreaCalc)
|
---|
2199 |
|
---|
2200 | - fixed some bugs in the Hillas calculation
|
---|
2201 |
|
---|
2202 | - added filters to be able to control the task execution dependent on
|
---|
2203 | a parameter (for example: the number of level 1 triggers in a MC-file)
|
---|
2204 |
|
---|
2205 |
|
---|
2206 |
|
---|
2207 | *** Version 0.3 (2001/04/23)
|
---|
2208 |
|
---|
2209 | - Many demo macros added
|
---|
2210 |
|
---|
2211 | - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
|
---|
2212 |
|
---|
2213 | - Hillas Calculation added
|
---|
2214 |
|
---|
2215 | - Standard image cleaning available
|
---|
2216 |
|
---|
2217 | - MReadTree is now able to handle more than one file
|
---|
2218 | (Remark: of the same structure)
|
---|
2219 |
|
---|
2220 | - Now we are able to display events in a first version of the
|
---|
2221 | Camera event display. To do this we must run the macro
|
---|
2222 | "macros/readCT1.C" to read data from CT1.
|
---|
2223 |
|
---|
2224 |
|
---|
2225 |
|
---|
2226 | *** Version 0.2 (2001/01/24)
|
---|
2227 |
|
---|
2228 | - First Implementation of a Gui to read the raw data. Start the
|
---|
2229 | gui with the command mars.
|
---|
2230 |
|
---|
2231 |
|
---|
2232 |
|
---|
2233 | *** Version 0.1 (2000/12/20)
|
---|
2234 |
|
---|
2235 | - First official release 0.1
|
---|
2236 |
|
---|
2237 | - Changes:
|
---|
2238 |
|
---|
2239 | + changed calling style of MRawPixelIterator from do...while to
|
---|
2240 | while-loop
|
---|