#!dimctrl --exec # ========================================================================== # Amplitude vs. Voltage Offset Measurement # ========================================================================== # Script for Amplitude vs. Voltage Offset Measurement # call it by: .x ScriptsForDimCtrl/AmplVsOv.dim V = # ---------------------------------------------------- > changing feedback voltage offset to ${V} FEEDBACK/STOP # STOP FEEDBACK .w 1000 # wait 1 second FEEDBACK/START_CURRENT_CONTROL ${V} # set Current_Control to given Offset value > ...checking if Voltage is ON # will ramp if not at nominal, will skip ramping if Voltage on .s BIAS_CONTROL 7 3000 1 > Voltage is OFF, will ramp to nominal Voltage BIAS_CONTROL/SET_GLOBAL_DAC 1 .s BIAS_CONTROL 9 .s BIAS_CONTROL 5 > ...ramping .s BIAS_CONTROL 9 :1 > Voltage is ON, waiting 45 sec for current_control to stabilize .w 42000 # wait 30 second for the current updates > OPERATOR: Write down: V_offset ${V}, Med(V), Med(I) and the Run number to the Excel file > starting LPext with 1000 Events # start external Lightpulser Run with 1000 Events # take a ExtLP run .x ScriptsForDimCtrl/ServiceScripts/TakeExtLpRun.dim FEEDBACK/STOP # STOP FEEDBACK > ...Feedback stopped > > OPERATOR: make sure to restart the feedback with the correct offset when resuming data taking > > ...done