# Move Telescope to Wobble Position 1 > > data taking script for Wobble 1 starting up... > ---------------------------------------------------- > > Operator: make sure that telescope is tracking wobble position 1 of source > #> ... This script will wait 10sec for you #.w 10000 FEEDBACK/ENABLE_OUTPUT 1 # Making sure bias is off BIAS_CONTROL/SET_ZERO_VOLTAGE .s BIAS_CONTROL 7 FAD_CONTROL/START_DRS_CALIBRATION > bias voltage is switched off > > taking DRS:Pedestal 1000 ... .s FAD_CONTROL 4 MCP/START -1 1000 drs-pedestal .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > taking DRS:Gain 1000 ... MCP/START -1 1000 drs-gain .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > taking DRS:Pedestal 1000 ... MCP/START -1 1000 drs-pedestal .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > taking crosscheck DRS:Pedestal 1000 ... FAD_CONTROL/SET_FILE_FORMAT 2 MCP/START -1 1000 drs-pedestal .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > taking DRS:Time 1000 ... MCP/START -1 1000 drs-time .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > taking DRS:Time upshifted 1000 ... MCP/START -1 1000 drs-time-upshifted .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > taking Pedestal 1000 for secondary baseline... FAD_CONTROL/RESET_SECONDARY_DRS_BASELINE MCP/START -1 1000 pedestal .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > taking crosscheck Pedestal 1000 ... FAD_CONTROL/SET_FILE_FORMAT 2 MCP/START -1 1000 pedestal .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > Operator: Measure Sky Brightness # switch BIAS ON and ramp to nominal Voltage > checking feedback state .s FEEDBACK 12 > ... Current/Temp control active and voltage output enabled > switching on bias ... BIAS_CONTROL/SET_GLOBAL_DAC 1 .s BIAS_CONTROL 9 # Voltage ON > ...set 1 DAC .s BIAS_CONTROL 5 # Ramping > ...ramping .s BIAS_CONTROL 9 # Voltage ON > ...bias ON # here one should wait 30..45sec according to TB > bias is on, and feedback-program is working, but we wait 45sec for the current readings... .w 45000 > ... done # check if all subsystems are in the correct state .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking > taking Pedestal with BIAS on 1000 ... MCP/START -1 1000 pedestal .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done # check if all subsystems are in the correct state .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking > taking External Light Pulser with BIAS on 1000 ... MCP/START -1 1000 light-pulser-ext .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done #Data Taking with Full Trigger Area (4x5min) # check if all subsystems are in the correct state .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking > taking Data:FullTriggerArea 5min Run 1 ... MCP/START 300 -1 data .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done # check if all subsystems are in the correct state .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking > taking Data:FullTriggerArea 5min Run 2 ... MCP/START 300 -1 data .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done # check if all subsystems are in the correct state .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking > taking Data:FullTriggerArea 5min Run 3 ... MCP/START 300 -1 data .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done # check if all subsystems are in the correct state .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking > taking Data:FullTriggerArea 5min Run 4 ... MCP/START 300 -1 data .s FAD_CONTROL 8 .s FAD_CONTROL 4 > ... done > ---------------------------------------------------- > This is the end of data taking of Wobble 1 > ----------------------------------------------------