source: trunk/FACT++/ScriptsForDimCtrl/ResumeDataTaking.dim

Last change on this file was 14338, checked in by Jens Buss, 12 years ago
optimized output to 40 signs textwidth
File size: 2.0 KB
Line 
1#!dimctrl --exec
2
3# ==========================================================================
4# resume data taking
5# ==========================================================================
6# Script to resume data taking after it had to be aborted
7# during first run of four data runs
8
9# call it by: .x ScriptsForDimCtrl/ResumeDataTaking.dim N=<number of runs>
10# N = 1...4
11
12# ----------------------------------------------------
13
14> ======================================
15> resume taking ${N} data runs after
16> DataTaking was aborted...
17> ======================================
18> OPERATOR:
19> + make sure bias is switched on
20> + make sure feedback is running!!!
21> --------------------------------------
22
23# check if bias is ramped up and if feedback is running
24
25> ...waiting for BIAS_CONTROL
26> to be in state 9: VoltageOn
27.s BIAS_CONTROL 9
28
29> ...waiting for FEEDBACK
30> to be in state 12: CurrentControl
31.s FEEDBACK 12
32
33> ...waiting for BIAS_CONTROL
34> to be in state 9: VoltageOn
35.s BIAS_CONTROL 9
36
37> ...bias is on
38> ...feedback-program is working
39> waiting 45sec for the current readings
40> --------------------------------------
41.w 45000
42
43.j ${N}
44
45#Data Taking with Full Trigger Area (4x5min)
46
47:4
48.x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim
49> taking Data:FullTriggerArea 5min Run
50MCP/START 300 -1 data
51.s FAD_CONTROL 8
52.s FAD_CONTROL 4
53> ... done
54
55:3
56.x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim
57> taking Data:FullTriggerArea 5min Run
58MCP/START 300 -1 data
59.s FAD_CONTROL 8
60.s FAD_CONTROL 4
61> ... done
62
63:2
64.x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim
65> taking Data:FullTriggerArea 5min Run
66MCP/START 300 -1 data
67.s FAD_CONTROL 8
68.s FAD_CONTROL 4
69> ... done
70
71:1
72.x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim
73> taking Data:FullTriggerArea 5min Run
74MCP/START 300 -1 data
75.s FAD_CONTROL 8
76.s FAD_CONTROL 4
77> ... done
78
79> ======================================
80> resumed data taking finished
81> ======================================
82
Note: See TracBrowser for help on using the repository browser.