1 | #!dimctrl --exec
|
---|
2 |
|
---|
3 | # ==========================================================================
|
---|
4 | # check feedback state before switching BIAS ON and ramping up to nominal Voltage
|
---|
5 | # ==========================================================================
|
---|
6 |
|
---|
7 | > checking feedback state
|
---|
8 | .s FEEDBACK 12 10000 60 # Current Control?
|
---|
9 | .j 61
|
---|
10 |
|
---|
11 | :60
|
---|
12 | > ===================================================
|
---|
13 | > feedback is not in state "CurrentControl"
|
---|
14 | >
|
---|
15 | > OPERATOR:
|
---|
16 | > goto feedback console and check the state of
|
---|
17 | > feedback by typing [st] to find out what the
|
---|
18 | > current state means and maybe needs to be done
|
---|
19 | >
|
---|
20 | > this script will wait for state "CurrentControl"
|
---|
21 | > ===================================================
|
---|
22 | .s FEEDBACK 12 # Current Control?
|
---|
23 |
|
---|
24 | :61
|
---|
25 | > ... Current/Temp control active and voltage output enabled
|
---|
26 |
|
---|
27 | > switching on bias ...
|
---|
28 | BIAS_CONTROL/SET_GLOBAL_DAC 1
|
---|
29 |
|
---|
30 | > checking biasctrl state
|
---|
31 | .s BIAS_CONTROL 9 10000 70 # Voltage ON
|
---|
32 | .j 71
|
---|
33 |
|
---|
34 | :70
|
---|
35 | > ===================================================
|
---|
36 | > switching on bias not successfull
|
---|
37 | > biasctrl is not in state "VoltageOn"
|
---|
38 | >
|
---|
39 | > OPERATOR:
|
---|
40 | > goto biasctrl console and check the state of
|
---|
41 | > biasctrl by typing [st] to find out what the
|
---|
42 | > current state means and maybe needs to be done
|
---|
43 | >
|
---|
44 | > this script will wait for state "VoltageOn"
|
---|
45 | > ===================================================
|
---|
46 | .s BIAS_CONTROL 9 # Voltage ON
|
---|
47 |
|
---|
48 | :71
|
---|
49 | > ...set 1 DAC
|
---|
50 |
|
---|
51 | .s BIAS_CONTROL 5 # Ramping
|
---|
52 | > ...ramping
|
---|
53 | .s BIAS_CONTROL 9 # Voltage ON
|
---|
54 | > ...bias ON
|
---|
55 |
|
---|
56 |
|
---|
57 | # here one should wait 30..45sec according to TB
|
---|
58 | > bias is on, and feedback-program is working, but we wait 45sec for the current readings...
|
---|
59 | .w 45000
|
---|
60 | > ... done
|
---|