Last change
on this file since 14390 was 14276, checked in by Jens Buss, 12 years ago |
initial commit: switch on feedback and bias
|
File size:
1.5 KB
|
Line | |
---|
1 | #!dimctrl --exec
|
---|
2 |
|
---|
3 | # ==========================================================================
|
---|
4 | # bring Feedback to state CurrentContro Idle and switch on Bias
|
---|
5 | # ==========================================================================
|
---|
6 |
|
---|
7 | > switching on current controll feedback
|
---|
8 | FEEDBACK/STOP
|
---|
9 |
|
---|
10 | > ... starting current control feedback
|
---|
11 | FEEDBACK/START_CURRENT_CONTROL 0.0
|
---|
12 | FEEDBACK/ENABLE_OUTPUT yes
|
---|
13 |
|
---|
14 | # the feedback should be in state 'CurrentCtrlIdle'(9) now since 30.05.12
|
---|
15 | > ...waiting for FEEDBACK to be in state 9: CurrentCtrlIdle
|
---|
16 | .s FEEDBACK 9
|
---|
17 | > ... done, feedback running
|
---|
18 | >
|
---|
19 | > switching bias on, sending one DAC globally
|
---|
20 |
|
---|
21 | # now we give the feedback a hint, that it may ramp ...
|
---|
22 | BIAS_CONTROL/SET_GLOBAL_DAC 1
|
---|
23 | # after this command the bias_ctrl should be in state 'VoltageOn'(9) after a second or so
|
---|
24 |
|
---|
25 | > ...waiting for BIAS to be in state 9: VoltageOn
|
---|
26 | .s BIAS_CONTROL 9
|
---|
27 | > ...1 DAC globally set
|
---|
28 |
|
---|
29 | # then usually it takes some time until the feedback has enough information to really start controlling the voltage
|
---|
30 | # when the feedback actually kicks in, the bias is first in state 'Ramping'(5) for some seconds and finally in 'VoltageOn'(9)
|
---|
31 | # again
|
---|
32 |
|
---|
33 | > ...waiting for BIAS to be in state 5: Ramping
|
---|
34 | .s BIAS_CONTROL 5
|
---|
35 | > ...ramping to nominal voltage
|
---|
36 |
|
---|
37 | > ...waiting for BIAS to be in state 9: VoltageOn
|
---|
38 | .s BIAS_CONTROL 9
|
---|
39 | > ...bias on
|
---|
40 |
|
---|
41 | # here we should wait 45 sec in order for the current control to get enough current readings and temp readings to stabilize..
|
---|
42 | > waiting 45sec for the current control to stabilize...
|
---|
43 | .w 45000
|
---|
44 | > ... done, bias on
|
---|
Note:
See
TracBrowser
for help on using the repository browser.