| 1 | /**
|
|---|
| 2 | * @fileOverview This file has functions related to documenting JavaScript.
|
|---|
| 3 | * @author <a href="mailto:thomas.bretz@epfl.ch">Thomas Bretz</a>
|
|---|
| 4 | */
|
|---|
| 5 | 'use strict';
|
|---|
| 6 |
|
|---|
| 7 | //this is just the class implementation of 'Observation'
|
|---|
| 8 | include('scripts/Observation_class.js');
|
|---|
| 9 |
|
|---|
| 10 | // this file just contains the definition of
|
|---|
| 11 | // the variable observations, which builds our nightly schedule, hence the filename
|
|---|
| 12 | include('scripts/schedule.js');
|
|---|
| 13 |
|
|---|
| 14 | // make Observation objects from user input and check if 'date' is increasing.
|
|---|
| 15 | for (var i=0; i<observations.length; i++)
|
|---|
| 16 | {
|
|---|
| 17 | observations[i] = new Observation(observations[i]);
|
|---|
| 18 |
|
|---|
| 19 | // check if the start date given by the user is increasing.
|
|---|
| 20 | if (i>0 && observations[i].start <= observations[i-1].start)
|
|---|
| 21 | {
|
|---|
| 22 | throw new Error("Start time '"+ observations[i].start.toUTCString()+
|
|---|
| 23 | "' in row "+i+" exceeds start time in row "+(i-1));
|
|---|
| 24 | }
|
|---|
| 25 | }
|
|---|
| 26 |
|
|---|
| 27 | // ----------------------------------------------------------------
|
|---|
| 28 | // ================================================================
|
|---|
| 29 | // ----------------------------------------------------------------
|
|---|
| 30 |
|
|---|
| 31 | dimctrl.defineState(37, "TimeOutBeforeTakingData", "MCP took more than 5minutes to start TakingData");
|
|---|
| 32 |
|
|---|
| 33 |
|
|---|
| 34 | // error handline : http://www.sitepoint.com/exceptional-exception-handling-in-javascript/
|
|---|
| 35 | // classes: http://www.phpied.com/3-ways-to-define-a-javascript-class/
|
|---|
| 36 | //
|
|---|
| 37 | // Arguments: TakeFirstDrsCalib
|
|---|
| 38 | // To be determined: How to stop the script without foreceful interruption?
|
|---|
| 39 |
|
|---|
| 40 | //
|
|---|
| 41 | // SCRIPTS:
|
|---|
| 42 | //
|
|---|
| 43 | // - Startup, e.g. do not open LID
|
|---|
| 44 | //
|
|---|
| 45 | // - Bring telescop to state 'operational', e.g. open lid,
|
|---|
| 46 | // when first run != START is detected in the loop
|
|---|
| 47 | //
|
|---|
| 48 | // - Take data
|
|---|
| 49 | //
|
|---|
| 50 | // - Shutdown
|
|---|
| 51 | //
|
|---|
| 52 | // ----> Does smartfact display alarm messages already?
|
|---|
| 53 | // ----> How to display errors in smartfact? Is that necessary at all?
|
|---|
| 54 | // (red output? maybe just <red>...</red>?
|
|---|
| 55 | //
|
|---|
| 56 | // ----------------------------------------------------------------
|
|---|
| 57 |
|
|---|
| 58 | function currentEst(source)
|
|---|
| 59 | {
|
|---|
| 60 | var moon = new Moon();
|
|---|
| 61 | if (!moon.isUp)
|
|---|
| 62 | return 7.7;
|
|---|
| 63 |
|
|---|
| 64 | var dist = Sky.dist(moon, source);
|
|---|
| 65 |
|
|---|
| 66 | var alt = 90-moon.toLocal().zd;
|
|---|
| 67 |
|
|---|
| 68 | var lc = dist*alt*pow(Moon.disk(), 6)/360/360;
|
|---|
| 69 |
|
|---|
| 70 | var cur = 7.7+4942*lc;
|
|---|
| 71 |
|
|---|
| 72 | return cur;
|
|---|
| 73 | }
|
|---|
| 74 |
|
|---|
| 75 | function thresholdEst(source) // relative threshold (ratio)
|
|---|
| 76 | {
|
|---|
| 77 | // Assumption:
|
|---|
| 78 | // atmosphere is 70km, shower taks place after 60km, earth radius 6400km
|
|---|
| 79 | // just using the cosine law
|
|---|
| 80 | // This fits very well with MC results: See Roger Firpo, p.45
|
|---|
| 81 | // "Study of the MAGIC telescope sensitivity for Large Zenith Angle observations"
|
|---|
| 82 |
|
|---|
| 83 | var c = Math.cos(Math.Pi-source.zd);
|
|---|
| 84 | var ratio = (10*sqrt(409600*c*c+9009) + 6400*c - 60)/10;
|
|---|
| 85 |
|
|---|
| 86 | // assumption: Energy threshold increases linearily with current
|
|---|
| 87 | // assumption: Energy threshold increases linearily with distance
|
|---|
| 88 |
|
|---|
| 89 | return ratio*currentEst(source)/7.7;
|
|---|
| 90 | }
|
|---|
| 91 |
|
|---|
| 92 | // Ratio in rate would be (estimate, not precise calculation)
|
|---|
| 93 | // pow(ratio, -0.7)
|
|---|
| 94 |
|
|---|
| 95 | // ----------------------------------------------------------------
|
|---|
| 96 |
|
|---|
| 97 | //DN: the name of the Subscription object 'service_con' is not really
|
|---|
| 98 | // telling that its a subscription to FAD_CONTROL/CONNECTIONS
|
|---|
| 99 | // fad_connections sound ok for be, since
|
|---|
| 100 | // fad_connections.onchange() is pretty clear
|
|---|
| 101 | // fad_connections.reconnect() is not really good, but at least it has FAD in it.
|
|---|
| 102 | var service_con = new Subscription("FAD_CONTROL/CONNECTIONS");
|
|---|
| 103 |
|
|---|
| 104 | /**
|
|---|
| 105 | * call-back function of FAD_CONTROL/CONNECTIONS
|
|---|
| 106 | * store IDs of problematic FADs
|
|---|
| 107 | *
|
|---|
| 108 | */
|
|---|
| 109 | service_con.onchange = function(evt)
|
|---|
| 110 | {
|
|---|
| 111 | // This happens, but why?
|
|---|
| 112 | if (!evt.obj['status'])
|
|---|
| 113 | return;
|
|---|
| 114 |
|
|---|
| 115 | this.reset = [ ];
|
|---|
| 116 |
|
|---|
| 117 | for (var x=0; x<40; x++)
|
|---|
| 118 | if (evt.obj['status'][x]!=66 && evt.obj['status'][x]!=67)
|
|---|
| 119 | this.reset.push(x);
|
|---|
| 120 |
|
|---|
| 121 | if (this.reset.length==0)
|
|---|
| 122 | return;
|
|---|
| 123 |
|
|---|
| 124 | //m.alarm("FAD board loss detected...");
|
|---|
| 125 | dim.send("MCP/RESET");
|
|---|
| 126 | dim.send("FAD_CONTROL/CLOSE_OPEN_FILES");
|
|---|
| 127 | }
|
|---|
| 128 |
|
|---|
| 129 | /**
|
|---|
| 130 | * reconnect to problematic FADs
|
|---|
| 131 | *
|
|---|
| 132 | * Dis- and Reconnects to FADs, found to be problematic by call-back function
|
|---|
| 133 | * onchange() to have a different CONNECTION value than 66 or 67.
|
|---|
| 134 | *
|
|---|
| 135 | * @returns
|
|---|
| 136 | * a boolean is returned.
|
|---|
| 137 | * reconnect returns true if:
|
|---|
| 138 | * * nothing needed to be reset --> no problems found by onchange()
|
|---|
| 139 | * * the reconnection went fine.
|
|---|
| 140 | *
|
|---|
| 141 | * reconnect *never returns false* so far.
|
|---|
| 142 | *
|
|---|
| 143 | * @example
|
|---|
| 144 | * if (!service_con.reconnect())
|
|---|
| 145 | * exit();
|
|---|
| 146 | */
|
|---|
| 147 | service_con.reconnect = function()
|
|---|
| 148 | {
|
|---|
| 149 | // this.reset is a list containing the IDs of FADs,
|
|---|
| 150 | // which have neither CONNECTION==66 nor ==67, whatever this means :-)
|
|---|
| 151 | if (this.reset.length==0)
|
|---|
| 152 | return true;
|
|---|
| 153 |
|
|---|
| 154 | console.out(" Reconnect: start ["+this.reset.length+"]");
|
|---|
| 155 |
|
|---|
| 156 | for (var i=0; i<this.reset.length; i++)
|
|---|
| 157 | dim.send("FAD_CONTROL/DISCONNECT", this.reset[i]);
|
|---|
| 158 |
|
|---|
| 159 | v8.sleep(3000);
|
|---|
| 160 |
|
|---|
| 161 | while (this.reset.length)
|
|---|
| 162 | dim.send("FAD_CONTROL/CONNECT", this.reset.pop());
|
|---|
| 163 |
|
|---|
| 164 | v8.sleep(1000);
|
|---|
| 165 | dim.wait("FAD_CONTROL", "Connected", 3000);
|
|---|
| 166 |
|
|---|
| 167 | console.out(" Reconnect: end");
|
|---|
| 168 |
|
|---|
| 169 | return true;
|
|---|
| 170 | }
|
|---|
| 171 |
|
|---|
| 172 | function takeRun(type, count, time)
|
|---|
| 173 | {
|
|---|
| 174 | if (!count)
|
|---|
| 175 | count = -1;
|
|---|
| 176 | if (!time)
|
|---|
| 177 | time = -1;
|
|---|
| 178 |
|
|---|
| 179 | console.out(" Take run: N="+count+" T="+time+"s ["+type+"]");
|
|---|
| 180 |
|
|---|
| 181 | dim.send("MCP/START", time?time:-1, count?count:-1, type);
|
|---|
| 182 |
|
|---|
| 183 | // What could be a reasonable timeout here?
|
|---|
| 184 | // FIXME: Replace by callback?
|
|---|
| 185 | //
|
|---|
| 186 | // DN: I believe instead of waiting for 'TakingData' one could split this
|
|---|
| 187 | // up into two checks with an extra condition:
|
|---|
| 188 | // if type == 'data':
|
|---|
| 189 | // wait until ThresholdCalibration starts:
|
|---|
| 190 | // --> this time should be pretty identical for each run
|
|---|
| 191 | // if this takes longer than say 3s:
|
|---|
| 192 | // there might be a problem with one/more FADs
|
|---|
| 193 | //
|
|---|
| 194 | // wait until "TakingData":
|
|---|
| 195 | // --> this seems to take even some minutes sometimes...
|
|---|
| 196 | // (might be optimized rather soon, but still in the moment...)
|
|---|
| 197 | // if this takes way too long:
|
|---|
| 198 | // there might be something broken,
|
|---|
| 199 | // so maybe a very high time limit is ok here.
|
|---|
| 200 | // I think there is not much that can go wrong,
|
|---|
| 201 | // when the Thr-Calib has already started. Still it might be nice
|
|---|
| 202 | // If in the future RateControl is written so to find out that
|
|---|
| 203 | // in case the threshold finding algorithm does
|
|---|
| 204 | // *not converge as usual*
|
|---|
| 205 | // it can complain, and in this way give a hint, that the weather
|
|---|
| 206 | // might be a little bit too bad.
|
|---|
| 207 | // else:
|
|---|
| 208 | // wait until "TakingData":
|
|---|
| 209 | // --> in a non-data run this time should be pretty short again
|
|---|
| 210 | // if this takes longer than say 3s:
|
|---|
| 211 | // there might be a problem with one/more FADs
|
|---|
| 212 | //
|
|---|
| 213 |
|
|---|
| 214 | if (!dim.wait("MCP", "TakingData", -300000) )
|
|---|
| 215 | {
|
|---|
| 216 | console.out("MCP took longer than 5 minutes to start TakingData");
|
|---|
| 217 | console.out("maybe this idicates a problem with one of the FADs?");
|
|---|
| 218 | dimctrl.setState(37);
|
|---|
| 219 | dim.wait("MCP", "TakingData", 500);
|
|---|
| 220 | }
|
|---|
| 221 | dim.wait("MCP", "Idle");
|
|---|
| 222 |
|
|---|
| 223 | console.out(" Take run: end");
|
|---|
| 224 |
|
|---|
| 225 | // DN: currently reconnect() never returns false
|
|---|
| 226 | // .. but it can fail of course.
|
|---|
| 227 | if (!service_con.reconnect())
|
|---|
| 228 | exit();
|
|---|
| 229 |
|
|---|
| 230 | return true;//service_con.reconnect();
|
|---|
| 231 | }
|
|---|
| 232 |
|
|---|
| 233 | // ----------------------------------------------------------------
|
|---|
| 234 |
|
|---|
| 235 | function doDrsCalibration()
|
|---|
| 236 | {
|
|---|
| 237 | console.out(" DRS cal: start");
|
|---|
| 238 | service_feedback.voltageOff();
|
|---|
| 239 |
|
|---|
| 240 | while (1)
|
|---|
| 241 | {
|
|---|
| 242 | dim.send("FAD_CONTROL/START_DRS_CALIBRATION");
|
|---|
| 243 | if (!takeRun("drs-pedestal", 1000)) // 40 / 20s (50Hz)
|
|---|
| 244 | continue;
|
|---|
| 245 | if (!takeRun("drs-gain", 1000)) // 40 / 20s (50Hz)
|
|---|
| 246 | continue;
|
|---|
| 247 | if (!takeRun("drs-pedestal", 1000)) // 40 / 20s (50Hz)
|
|---|
| 248 | continue;
|
|---|
| 249 |
|
|---|
| 250 | dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
|---|
| 251 | if (!takeRun("drs-pedestal", 1000)) // 40 / 20s (50Hz)
|
|---|
| 252 | continue;
|
|---|
| 253 | if (!takeRun("drs-time", 1000)) // 40 / 20s (50Hz)
|
|---|
| 254 | continue;
|
|---|
| 255 |
|
|---|
| 256 | dim.send("FAD_CONTROL/RESET_SECONDARY_DRS_BASELINE");
|
|---|
| 257 | if (!takeRun("pedestal", 1000)) // 40 / 10s (80Hz)
|
|---|
| 258 | continue;
|
|---|
| 259 |
|
|---|
| 260 | dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
|---|
| 261 | if (!takeRun("pedestal", 1000)) // 40 / 10s (80Hz)
|
|---|
| 262 | continue;
|
|---|
| 263 | // -----------
|
|---|
| 264 | // 4'40 / 2'00
|
|---|
| 265 |
|
|---|
| 266 | break;
|
|---|
| 267 | }
|
|---|
| 268 |
|
|---|
| 269 | dim.send("RATE_CONTROL/STOP"); // get out of GlobalThresholdSet
|
|---|
| 270 | dim.wait("RATE_CONTROL", "Connected", 3000);
|
|---|
| 271 |
|
|---|
| 272 | console.out(" DRS cal: end");
|
|---|
| 273 | }
|
|---|
| 274 |
|
|---|
| 275 | // ----------------------------------------------------------------
|
|---|
| 276 |
|
|---|
| 277 | function OpenLid()
|
|---|
| 278 | {
|
|---|
| 279 | var horizon_parameter = "nautical";
|
|---|
| 280 | while (Sun.horizon( horizon_parameter ).isUp)
|
|---|
| 281 | {
|
|---|
| 282 | var now = new Date();
|
|---|
| 283 | var minutes_until_sunset = (Sun.horizon( horizon_parameter ).set - now)/60000;
|
|---|
| 284 | console.out(now.toUTCString()+": Sun above FACT-horizon, lid cannot be opened: sleeping 1min, remaining %.1fmin".$(minutes_until_sunset));
|
|---|
| 285 | v8.sleep(60000);
|
|---|
| 286 | }
|
|---|
| 287 |
|
|---|
| 288 | var isClosed = dim.state("LID_CONTROL").name=="Closed";
|
|---|
| 289 |
|
|---|
| 290 | // Wait for lid to be open
|
|---|
| 291 | if (isClosed)
|
|---|
| 292 | {
|
|---|
| 293 | console.out(" Open lid: start");
|
|---|
| 294 | dim.send("LID_CONTROL/OPEN");
|
|---|
| 295 | }
|
|---|
| 296 | dim.wait("LID_CONTROL", "Open", 30000);
|
|---|
| 297 |
|
|---|
| 298 | if (isClosed)
|
|---|
| 299 | console.out(" Open lid: done");
|
|---|
| 300 | }
|
|---|
| 301 |
|
|---|
| 302 | function CloseLid()
|
|---|
| 303 | {
|
|---|
| 304 | var isOpen = dim.state("LID_CONTROL").name=="Open";
|
|---|
| 305 |
|
|---|
| 306 | // Wait for lid to be open
|
|---|
| 307 | if (isOpen)
|
|---|
| 308 | {
|
|---|
| 309 | console.out(" Close lid: start");
|
|---|
| 310 | dim.send("LID_CONTROL/CLOSE");
|
|---|
| 311 | }
|
|---|
| 312 | dim.wait("LID_CONTROL", "Closed", 30000);
|
|---|
| 313 |
|
|---|
| 314 | if (isOpen)
|
|---|
| 315 | console.out(" Close lid: end");
|
|---|
| 316 | }
|
|---|
| 317 |
|
|---|
| 318 | // ----------------------------------------------------------------
|
|---|
| 319 |
|
|---|
| 320 | var service_feedback = new Subscription("FEEDBACK/DEVIATION");
|
|---|
| 321 |
|
|---|
| 322 | // DN: Why is voltageOff() implemented as
|
|---|
| 323 | // a method of a Subscription to a specific Service
|
|---|
| 324 | // I naively would think of voltageOff() as an unbound function.
|
|---|
| 325 | // I seems to me it has to be a method of a Subscription object, in order
|
|---|
| 326 | // to use the update counting method. But does it have to be
|
|---|
| 327 | // a Subscription to FEEDBACK/DEVIATION, or could it work with other services as well?
|
|---|
| 328 | service_feedback.voltageOff = function()
|
|---|
| 329 | {
|
|---|
| 330 | var state = dim.state("BIAS_CONTROL").name;
|
|---|
| 331 |
|
|---|
| 332 | // check of feedback has to be switched on
|
|---|
| 333 | var isOn = state=="VoltageOn" || state=="Ramping";
|
|---|
| 334 | if (isOn)
|
|---|
| 335 | {
|
|---|
| 336 | console.out(" Voltage off: start");
|
|---|
| 337 |
|
|---|
| 338 | // Supress the possibility that the bias control is
|
|---|
| 339 | // ramping and will reject the command to switch the
|
|---|
| 340 | // voltage off
|
|---|
| 341 | var isControl = dim.state("FEEDBACK").name=="CurrentControl";
|
|---|
| 342 | if (isControl)
|
|---|
| 343 | {
|
|---|
| 344 | console.out(" Suspending feedback.");
|
|---|
| 345 | dim.send("FEEDBACK/ENABLE_OUTPUT", false);
|
|---|
| 346 | dim.wait("FEEDBACK", "CurrentCtrlIdle", 3000);
|
|---|
| 347 | }
|
|---|
| 348 |
|
|---|
| 349 | // Switch voltage off
|
|---|
| 350 | console.out(" Voltage on: switch off");
|
|---|
| 351 | dim.send("BIAS_CONTROL/SET_ZERO_VOLTAGE");
|
|---|
| 352 |
|
|---|
| 353 | // If the feedback was enabled, re-enable it
|
|---|
| 354 | if (isControl)
|
|---|
| 355 | {
|
|---|
| 356 | console.out(" Resuming feedback.");
|
|---|
| 357 | dim.send("FEEDBACK/ENABLE_OUTPUT", true);
|
|---|
| 358 | dim.wait("FEEDBACK", "CurrentControl", 3000);
|
|---|
| 359 | }
|
|---|
| 360 | }
|
|---|
| 361 |
|
|---|
| 362 | dim.wait("BIAS_CONTROL", "VoltageOff", 5000);
|
|---|
| 363 |
|
|---|
| 364 | // FEEDBACK stays in CurrentCtrl when Voltage is off but output enabled
|
|---|
| 365 | // dim.wait("FEEDBACK", "CurrentCtrlIdle", 1000);
|
|---|
| 366 |
|
|---|
| 367 | if (isOn)
|
|---|
| 368 | console.out(" Voltage off: end");
|
|---|
| 369 | }
|
|---|
| 370 |
|
|---|
| 371 | // DN: The name of the method voltageOn() in the context of the method
|
|---|
| 372 | // voltageOff() is a little bit misleading, since when voltageOff() returns
|
|---|
| 373 | // the caller can be sure the voltage is off, but when voltageOn() return
|
|---|
| 374 | // this is not the case, in the sense, that the caller can now take data.
|
|---|
| 375 | // instead the caller of voltageOn() *must* call waitForVoltageOn() afterwards
|
|---|
| 376 | // in order to safely take good-quality data.
|
|---|
| 377 | // This could lead to nasty bugs in the sense, that the second call might
|
|---|
| 378 | // be forgotten by somebody
|
|---|
| 379 | //
|
|---|
| 380 | // so I suggest to rename voltageOn() --> prepareVoltageOn()
|
|---|
| 381 | // waitForVoltageOn() stays as it is
|
|---|
| 382 | // and one creates a third method called:voltageOn() like this
|
|---|
| 383 | /* service_feedback.voltageOn = function()
|
|---|
| 384 | * {
|
|---|
| 385 | * this.prepareVoltageOn();
|
|---|
| 386 | * this.waitForVoltageOn();
|
|---|
| 387 | * }
|
|---|
| 388 | *
|
|---|
| 389 | * */
|
|---|
| 390 | // For convenience.
|
|---|
| 391 |
|
|---|
| 392 | service_feedback.voltageOn = function()
|
|---|
| 393 | {
|
|---|
| 394 | //if (Sun.horizon("FACT").isUp)
|
|---|
| 395 | // throw new Error("Sun is above FACT-horizon, voltage cannot be switched on.");
|
|---|
| 396 |
|
|---|
| 397 | var isOff = dim.state("BIAS_CONTROL").name=="VoltageOff";
|
|---|
| 398 | if (isOff)
|
|---|
| 399 | {
|
|---|
| 400 | console.out(" Voltage on: switch on");
|
|---|
| 401 | //console.out(JSON.stringify(dim.state("BIAS_CONTROL")));
|
|---|
| 402 |
|
|---|
| 403 | dim.send("BIAS_CONTROL/SET_GLOBAL_DAC", 1);
|
|---|
| 404 | }
|
|---|
| 405 |
|
|---|
| 406 | // Wait until voltage on
|
|---|
| 407 | dim.wait("BIAS_CONTROL", "VoltageOn", 5000);
|
|---|
| 408 |
|
|---|
| 409 | // From now on the feedback waits for a valid report from the FSC
|
|---|
| 410 | // and than switchs to CurrentControl
|
|---|
| 411 | dim.wait("FEEDBACK", "CurrentControl", 60000);
|
|---|
| 412 |
|
|---|
| 413 | if (isOff)
|
|---|
| 414 | {
|
|---|
| 415 | this.cnt = this.get().counter;
|
|---|
| 416 | console.out(" Voltage on: cnt="+this.cnt);
|
|---|
| 417 | }
|
|---|
| 418 | }
|
|---|
| 419 |
|
|---|
| 420 | service_feedback.waitForVoltageOn = function()
|
|---|
| 421 | {
|
|---|
| 422 | // waiting 45sec for the current control to stabilize...
|
|---|
| 423 | // v8.sleep(45000);
|
|---|
| 424 |
|
|---|
| 425 | // ----- Wait for at least three updates -----
|
|---|
| 426 | // The feedback is started as if the camera where at 0deg
|
|---|
| 427 | // Then after the first temp update, the temperature will be set to the
|
|---|
| 428 | // correct value (this has already happened)
|
|---|
| 429 | // So we only have to wait for the current to get stable.
|
|---|
| 430 | // This should happen after three to five current updates.
|
|---|
| 431 | // So we want one recent temperature update
|
|---|
| 432 | // and three recent current updates
|
|---|
| 433 |
|
|---|
| 434 | // Avoid output if condition is already fulfilled
|
|---|
| 435 | if (this.cnt && this.get().counter>this.cnt+2)
|
|---|
| 436 | return;
|
|---|
| 437 |
|
|---|
| 438 | // FIXME: timeout missing
|
|---|
| 439 | console.out(" Feedback wait: start");
|
|---|
| 440 |
|
|---|
| 441 | var now = new Date();
|
|---|
| 442 | while (this.cnt==undefined || this.get().counter<=this.cnt+2)
|
|---|
| 443 | v8.sleep();
|
|---|
| 444 |
|
|---|
| 445 | console.out(" Feedback wait: end [cnt=%d, %.2fs]".$(this.get().counter, (new Date()-now)/1000));
|
|---|
| 446 | }
|
|---|
| 447 |
|
|---|
| 448 | // ================================================================
|
|---|
| 449 | // Crosscheck all states
|
|---|
| 450 | // ================================================================
|
|---|
| 451 |
|
|---|
| 452 | include('scripts/Startup.js');//Startup();
|
|---|
| 453 |
|
|---|
| 454 | /*
|
|---|
| 455 | include('scripts/CheckStates.js');
|
|---|
| 456 |
|
|---|
| 457 | var table =
|
|---|
| 458 | [
|
|---|
| 459 | [ "TNG_WEATHER" ],
|
|---|
| 460 | [ "MAGIC_WEATHER" ],
|
|---|
| 461 | [ "CHAT" ],
|
|---|
| 462 | [ "SMART_FACT" ],
|
|---|
| 463 | [ "FSC_CONTROL", [ "Connected" ] ],
|
|---|
| 464 | [ "MCP", [ "Idle" ] ],
|
|---|
| 465 | [ "TIME_CHECK", [ "Valid" ] ],
|
|---|
| 466 | [ "PWR_CONTROL", [ "SystemOn" ] ],
|
|---|
| 467 | [ "AGILENT_CONTROL", [ "VoltageOn" ] ],
|
|---|
| 468 | [ "BIAS_CONTROL", [ "VoltageOff" ] ],
|
|---|
| 469 | [ "FEEDBACK", [ "CurrentControl", "CurrentCtrlIdle", "Connected" ] ],
|
|---|
| 470 | [ "RATE_SCAN", [ "Connected" ] ],
|
|---|
| 471 | [ "RATE_CONTROL", [ "Connected" ] ],
|
|---|
| 472 | [ "LID_CONTROL", [ "Open", "Closed" ] ],
|
|---|
| 473 | [ "DRIVE_CONTROL", [ "Armed", "Tracking", "OnTrack" ] ],
|
|---|
| 474 | [ "FTM_CONTROL", [ "Idle", "TriggerOn" ] ],
|
|---|
| 475 | [ "FAD_CONTROL", [ "Connected", "WritingData" ] ],
|
|---|
| 476 | [ "DATA_LOGGER", [ "NightlyFileOpen", "WaitForRun", "Logging" ] ],
|
|---|
| 477 | ];
|
|---|
| 478 |
|
|---|
| 479 | console.out("Checking states.");
|
|---|
| 480 | if (!checkStates(table, 10000))
|
|---|
| 481 | {
|
|---|
| 482 | throw new Error"Something unexpected has happened. Although the startup-",
|
|---|
| 483 | "procedure has finished, not all servers are in the state",
|
|---|
| 484 | "in which they ought to be. Please, try to find out what",
|
|---|
| 485 | "happened...");
|
|---|
| 486 | }
|
|---|
| 487 |
|
|---|
| 488 | console.out("Checking states: done.");
|
|---|
| 489 | */
|
|---|
| 490 | // ----------------------------------------------------------------
|
|---|
| 491 |
|
|---|
| 492 | console.out("Checking send.");
|
|---|
| 493 | checkSend(["MCP", "DRIVE_CONTROL", "LID_CONTROL", "FAD_CONTROL", "FEEDBACK"]);
|
|---|
| 494 | console.out("Checking send: done");
|
|---|
| 495 |
|
|---|
| 496 | // ----------------------------------------------------------------
|
|---|
| 497 |
|
|---|
| 498 | console.out("Feedback init: start.");
|
|---|
| 499 | service_feedback.get(5000);
|
|---|
| 500 |
|
|---|
| 501 | dim.send("FEEDBACK/ENABLE_OUTPUT", true);
|
|---|
| 502 | dim.send("FEEDBACK/START_CURRENT_CONTROL", 0.);
|
|---|
| 503 |
|
|---|
| 504 | console.out("Feedback init: end.");
|
|---|
| 505 |
|
|---|
| 506 | // ----------------------------------------------------------------
|
|---|
| 507 | // Bring the system into a well defined state
|
|---|
| 508 | // ----------------------------------------------------------------
|
|---|
| 509 |
|
|---|
| 510 | console.out("Drs runs init: start.");
|
|---|
| 511 |
|
|---|
| 512 | // FIMXE: Double subscription is not allowed!
|
|---|
| 513 | // also Startup needs DRS_RUNS
|
|---|
| 514 | var service_drs = new Subscription("FAD_CONTROL/DRS_RUNS");
|
|---|
| 515 | service_drs.get(5000);
|
|---|
| 516 |
|
|---|
| 517 | console.out("Drs runs init: end.");
|
|---|
| 518 |
|
|---|
| 519 | // FIXME: Check if the last DRS calibration was complete?
|
|---|
| 520 | // ----------------------------------------------------------------
|
|---|
| 521 |
|
|---|
| 522 | // We have to stup a few things here which might not by set by Startup.js
|
|---|
| 523 | dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
|---|
| 524 |
|
|---|
| 525 | // ----------------------------------------------------------------
|
|---|
| 526 |
|
|---|
| 527 | console.out("Start main loop.");
|
|---|
| 528 |
|
|---|
| 529 | function Startup()
|
|---|
| 530 | {
|
|---|
| 531 | /**** dummy ****/
|
|---|
| 532 | console.out(" => [STARTUP] called.");
|
|---|
| 533 | }
|
|---|
| 534 |
|
|---|
| 535 | function Shutdown()
|
|---|
| 536 | {
|
|---|
| 537 | /**** dummy ****/
|
|---|
| 538 | //console.out(" => [SHUTDOWN] called.");
|
|---|
| 539 | console.out("Shutdown: start");
|
|---|
| 540 |
|
|---|
| 541 | dim.send("FTM_CONTROL/STOP_TRIGGER");
|
|---|
| 542 | service_feedback.voltageOff();
|
|---|
| 543 | CloseLid();
|
|---|
| 544 | dim.send("DRIVE_CONTROL/PARK");
|
|---|
| 545 |
|
|---|
| 546 | console.out("Waiting for telescope to park. This may take a while.");
|
|---|
| 547 |
|
|---|
| 548 | // FIXME: This might not work is the drive is already close to park position
|
|---|
| 549 | dim.wait("DRIVE_CONTROL", "Moving", 3000);
|
|---|
| 550 | dim.wait("DRIVE_CONTROL", "Armed", 120000);
|
|---|
| 551 |
|
|---|
| 552 | // dim.wait("DRIVE_CONTROL", "Locked", 3000);
|
|---|
| 553 |
|
|---|
| 554 | var sub = new Subscription("DRIVE_CONTROL/POINTING_POSITION");
|
|---|
| 555 | sub.get(5000); // FIXME: Proper error message in case of failure
|
|---|
| 556 |
|
|---|
| 557 | function func()
|
|---|
| 558 | {
|
|---|
| 559 | var report = sub.get();
|
|---|
| 560 |
|
|---|
| 561 | var zd = report.obj['Zd'];
|
|---|
| 562 | var az = report.obj['Az'];
|
|---|
| 563 |
|
|---|
| 564 | if (zd>100 && Math.abs(az)<1)
|
|---|
| 565 | return true;
|
|---|
| 566 |
|
|---|
| 567 | return undefined;
|
|---|
| 568 | }
|
|---|
| 569 |
|
|---|
| 570 | v8.timeout(150000, func);
|
|---|
| 571 |
|
|---|
| 572 | // FIXME: Add a check for the position here!
|
|---|
| 573 |
|
|---|
| 574 | console.out("Shutdown: end");
|
|---|
| 575 | }
|
|---|
| 576 |
|
|---|
| 577 | // Get the observation scheduled for 'now' from the table and
|
|---|
| 578 | // return its index
|
|---|
| 579 | function getObservation(now)
|
|---|
| 580 | {
|
|---|
| 581 | if (now==undefined)
|
|---|
| 582 | now = new Date();
|
|---|
| 583 |
|
|---|
| 584 | if (isNaN(now.valueOf()))
|
|---|
| 585 | throw new Error("Date argument in getObservation invalid.");
|
|---|
| 586 |
|
|---|
| 587 | for (var i=0; i<observations.length; i++)
|
|---|
| 588 | if (now<observations[i].start)
|
|---|
| 589 | return i-1;
|
|---|
| 590 |
|
|---|
| 591 | return observations.length-1;
|
|---|
| 592 | }
|
|---|
| 593 |
|
|---|
| 594 |
|
|---|
| 595 | // DN: using so called magic numbers to encode certain
|
|---|
| 596 | // states of the logic is considered pretty bad coding as far as I understand.
|
|---|
| 597 | // the reader at this point has no idea why run is -2 ... this is the first time she
|
|---|
| 598 | // reads about this variable and there is not a word of explanation found.
|
|---|
| 599 | var run = -2; // getObservation never called
|
|---|
| 600 | var sub;
|
|---|
| 601 | var lastObs;
|
|---|
| 602 |
|
|---|
| 603 | var test = getObservation();
|
|---|
| 604 | if (test!=undefined)
|
|---|
| 605 | {
|
|---|
| 606 | var n = new Date();
|
|---|
| 607 | if (test==-1)
|
|---|
| 608 | console.out(n.toUTCString()+": First observation scheduled for "+observations[0].start.toUTCString());
|
|---|
| 609 | if (test>=0 && test<observations.length)
|
|---|
| 610 | console.out(n.toUTCString()+": First observation should start immediately.");
|
|---|
| 611 | if (observations[0].start>n+12*3600*1000)
|
|---|
| 612 | console.out(n.toUTCString()+": No observations scheduled for the next 12 hours!");
|
|---|
| 613 | }
|
|---|
| 614 |
|
|---|
| 615 | while (1)
|
|---|
| 616 | {
|
|---|
| 617 | // Check if observation position is still valid
|
|---|
| 618 | // If source position has changed, set run=0
|
|---|
| 619 | var idxObs = getObservation();
|
|---|
| 620 | if (idxObs===undefined)
|
|---|
| 621 | exit();
|
|---|
| 622 |
|
|---|
| 623 | // we are still waiting for the first observation in the schedule
|
|---|
| 624 | if (idxObs==-1)
|
|---|
| 625 | {
|
|---|
| 626 | // flag that the first observation will be in the future
|
|---|
| 627 | run = -1;
|
|---|
| 628 | v8.sleep(1000);
|
|---|
| 629 | continue;
|
|---|
| 630 | }
|
|---|
| 631 |
|
|---|
| 632 | var obs = observations[idxObs];
|
|---|
| 633 | var nextObs = observations[idxObs+1];
|
|---|
| 634 |
|
|---|
| 635 | // Check if observation target has changed
|
|---|
| 636 | if (lastObs!=idxObs) // !Object.isEqual(obs, nextObs)
|
|---|
| 637 | {
|
|---|
| 638 | console.out("--- "+idxObs+" ---");
|
|---|
| 639 | console.out("Current time: "+new Date().toUTCString());
|
|---|
| 640 | console.out("Current observation: "+obs.start.toUTCString());
|
|---|
| 641 | if (nextObs!=undefined)
|
|---|
| 642 | console.out("Next observation: "+nextObs.start.toUTCString());
|
|---|
| 643 | console.out("");
|
|---|
| 644 |
|
|---|
| 645 | // This is the first source, but we do not come from
|
|---|
| 646 | // a scheduled 'START', so we have to check if the
|
|---|
| 647 | // telescop is operational already
|
|---|
| 648 | sub = 0;
|
|---|
| 649 | if (run<0)
|
|---|
| 650 | {
|
|---|
| 651 | Startup(); // -> Bias On/Off?, Lid open/closed?
|
|---|
| 652 | CloseLid();
|
|---|
| 653 | }
|
|---|
| 654 |
|
|---|
| 655 | // The first observation had a start-time in the past...
|
|---|
| 656 | // In this particular case start with the last entry
|
|---|
| 657 | // in the list of measurements
|
|---|
| 658 | if (run==-2)
|
|---|
| 659 | sub = obs.length-1;
|
|---|
| 660 |
|
|---|
| 661 | run = 0;
|
|---|
| 662 | }
|
|---|
| 663 | lastObs = idxObs;
|
|---|
| 664 |
|
|---|
| 665 | if (nextObs==undefined && obs[obs.length-1].task!="SHUTDOWN")
|
|---|
| 666 | throw Error("Last scheduled measurement must be a shutdown.");
|
|---|
| 667 |
|
|---|
| 668 | // We are done with all measurement slots for this
|
|---|
| 669 | // observation... wait for next observation
|
|---|
| 670 | if (sub>=obs.length)
|
|---|
| 671 | {
|
|---|
| 672 | v8.sleep(1000);
|
|---|
| 673 | continue;
|
|---|
| 674 | }
|
|---|
| 675 | // add time
|
|---|
| 676 | console.out("\n"+(new Date()).toUTCString()+": Current measurement: "+obs[sub]);
|
|---|
| 677 |
|
|---|
| 678 | // Check if obs.task is one of the one-time-tasks
|
|---|
| 679 | switch (obs[sub].task)
|
|---|
| 680 | {
|
|---|
| 681 | case "STARTUP":
|
|---|
| 682 | console.out(" STARTUP", "");
|
|---|
| 683 | Startup(); // BiasOn/Off?, Lid open/close?
|
|---|
| 684 | CloseLid();
|
|---|
| 685 |
|
|---|
| 686 | console.out(" Take DRS calibration.");
|
|---|
| 687 | doDrsCalibration(); // -> VoltageOff
|
|---|
| 688 |
|
|---|
| 689 | service_feedback.voltageOn();
|
|---|
| 690 | service_feedback.waitForVoltageOn();
|
|---|
| 691 |
|
|---|
| 692 | // Before we can switch to 3000 we have to make the right DRS calibration
|
|---|
| 693 | console.out(" Take single p.e. run.");
|
|---|
| 694 | while (!takeRun("pedestal", 5000));
|
|---|
| 695 |
|
|---|
| 696 | service_feedback.voltageOff();
|
|---|
| 697 |
|
|---|
| 698 | dim.send("RATE_CONTROL/STOP"); // get out of GlobalThresholdSet
|
|---|
| 699 | dim.wait("RATE_CONTROL", "Connected", 3000);
|
|---|
| 700 |
|
|---|
| 701 | console.out(" Waiting for first scheduled observation.","");
|
|---|
| 702 | sub++;
|
|---|
| 703 | continue;
|
|---|
| 704 |
|
|---|
| 705 | case "SHUTDOWN":
|
|---|
| 706 | console.out(" SHUTDOWN","");
|
|---|
| 707 | Shutdown();
|
|---|
| 708 |
|
|---|
| 709 | console.out(" Waiting for next startup.", "");
|
|---|
| 710 | sub++;
|
|---|
| 711 | continue;
|
|---|
| 712 |
|
|---|
| 713 | case "IDLE":
|
|---|
| 714 | // FIXME: Checks missing whether a shutdown is needed...
|
|---|
| 715 | v8.sleep(1000);
|
|---|
| 716 | continue;
|
|---|
| 717 |
|
|---|
| 718 | case "RATESCAN":
|
|---|
| 719 | console.out(" RATESCAN ");
|
|---|
| 720 |
|
|---|
| 721 | if (dim.state("FTM_CONTROL").name=="TriggerOn")
|
|---|
| 722 | {
|
|---|
| 723 | dim.send("FTM_CONTROL/STOP_TRIGGER");
|
|---|
| 724 | dim.wait("FTM_CONTROL", "Idle", 3000);
|
|---|
| 725 | }
|
|---|
| 726 |
|
|---|
| 727 | dim.send("DRIVE_CONTROL/STOP");
|
|---|
| 728 | dim.wait("DRIVE_CONTROL", "Armed", 5000);
|
|---|
| 729 |
|
|---|
| 730 | OpenLid();
|
|---|
| 731 |
|
|---|
| 732 | service_feedback.voltageOn();
|
|---|
| 733 |
|
|---|
| 734 | if (obs.source != undefined)
|
|---|
| 735 | dim.send("DRIVE_CONTROL/TRACK_ON", obs[sub].source);
|
|---|
| 736 | else
|
|---|
| 737 | dim.send("DRIVE_CONTROL/TRACK", obs[sub].ra, obs[sub].dec);
|
|---|
| 738 |
|
|---|
| 739 | dim.wait("DRIVE_CONTROL", "OnTrack", 150000); // 110s for turning and 30s for stabilizing
|
|---|
| 740 |
|
|---|
| 741 | service_feedback.waitForVoltageOn();
|
|---|
| 742 |
|
|---|
| 743 | // Checking if system is Ready for Data Taking, which is in this case
|
|---|
| 744 | // the same as Ready for RateScan.
|
|---|
| 745 | console.out(" Checking states [ratescan]");
|
|---|
| 746 | var table =
|
|---|
| 747 | [
|
|---|
| 748 | [ "TNG_WEATHER" ],
|
|---|
| 749 | [ "MAGIC_WEATHER" ],
|
|---|
| 750 | [ "CHAT" ],
|
|---|
| 751 | [ "SMART_FACT" ],
|
|---|
| 752 | [ "DATA_LOGGER", [ "NightlyFileOpen", "WaitForRun", "Logging" ] ],
|
|---|
| 753 | [ "FSC_CONTROL", [ "Connected" ] ],
|
|---|
| 754 | [ "MCP", [ "Idle" ] ],
|
|---|
| 755 | [ "TIME_CHECK", [ "Valid" ] ],
|
|---|
| 756 | [ "PWR_CONTROL", [ "SystemOn" ] ],
|
|---|
| 757 | [ "AGILENT_CONTROL", [ "VoltageOn" ] ],
|
|---|
| 758 | [ "BIAS_CONTROL", [ "VoltageOn", "Ramping" ] ],
|
|---|
| 759 | [ "FEEDBACK", [ "CurrentControl" ] ],
|
|---|
| 760 | [ "RATE_SCAN", [ "Connected" ] ],
|
|---|
| 761 | [ "RATE_CONTROL", [ "Connected", "InProgress" ] ],
|
|---|
| 762 | [ "LID_CONTROL", [ "Open" ] ],
|
|---|
| 763 | [ "DRIVE_CONTROL", [ "Tracking", "OnTrack" ] ],
|
|---|
| 764 | [ "FTM_CONTROL", [ "Idle", ] ],
|
|---|
| 765 | [ "FAD_CONTROL", [ "Connected", "WritingData" ] ],
|
|---|
| 766 | ];
|
|---|
| 767 |
|
|---|
| 768 | if (!checkStates(table))
|
|---|
| 769 | {
|
|---|
| 770 | throw new Error("Something unexpected has happened. One of the servers"+
|
|---|
| 771 | "is in a state in which it should not be. Please,"+
|
|---|
| 772 | "try to find out what happened...");
|
|---|
| 773 | }
|
|---|
| 774 |
|
|---|
| 775 | // Start rate scan
|
|---|
| 776 | dim.send("RATE_SCAN/START_THRESHOLD_SCAN", 50, 1000, -10);
|
|---|
| 777 |
|
|---|
| 778 | // lets wait if the Ratescan really starts .. it should be started after 10sec max.
|
|---|
| 779 | dim.wait("RATE_SCAN", "InProgress", 10000);
|
|---|
| 780 | dim.wait("RATE_SCAN", "Connected", 2700000);
|
|---|
| 781 |
|
|---|
| 782 | // this line is actually some kind of hack.
|
|---|
| 783 | // after the Ratescan, no data is written to disk. I don't know why, but it happens all the time
|
|---|
| 784 | // So I decided to put this line here as a kind of patchwork....
|
|---|
| 785 | dim.send("FAD_CONTROL/SET_FILE_FORMAT", 2);
|
|---|
| 786 |
|
|---|
| 787 | console.out("Ratescan done.");
|
|---|
| 788 | sub++;
|
|---|
| 789 | continue;
|
|---|
| 790 | }
|
|---|
| 791 |
|
|---|
| 792 | // ========================== case "DATA" ============================
|
|---|
| 793 | /*
|
|---|
| 794 | if (Sun.horizon("FACT").isUp)
|
|---|
| 795 | {
|
|---|
| 796 | console.out(" SHUTDOWN","");
|
|---|
| 797 | Shutdown();
|
|---|
| 798 | console.out(" Exit forced due to broken schedule", "");
|
|---|
| 799 | exit();
|
|---|
| 800 | }
|
|---|
| 801 | */
|
|---|
| 802 | // Calculate remaining time for this observation in minutes
|
|---|
| 803 | var remaining = nextObs==undefined ? 0 : (nextObs.start-new Date())/60000;
|
|---|
| 804 |
|
|---|
| 805 | // ------------------------------------------------------------
|
|---|
| 806 |
|
|---|
| 807 | // Checking for 'Ramping' in the BIAS_CONTROL is not ideal, but at the moment
|
|---|
| 808 | // it is not possible to distinguish between a real ramping and the short
|
|---|
| 809 | // ramping which takes place whenever the feedback updated the voltages.
|
|---|
| 810 |
|
|---|
| 811 | console.out(" Checking states [mainloop]");
|
|---|
| 812 | var table =
|
|---|
| 813 | [
|
|---|
| 814 | [ "TNG_WEATHER" ],
|
|---|
| 815 | [ "MAGIC_WEATHER" ],
|
|---|
| 816 | [ "CHAT" ],
|
|---|
| 817 | [ "SMART_FACT" ],
|
|---|
| 818 | [ "DATA_LOGGER", [ "NightlyFileOpen", "WaitForRun", "Logging" ] ],
|
|---|
| 819 | [ "FSC_CONTROL", [ "Connected" ] ],
|
|---|
| 820 | [ "MCP", [ "Idle" ] ],
|
|---|
| 821 | [ "TIME_CHECK", [ "Valid" ] ],
|
|---|
| 822 | [ "PWR_CONTROL", [ "SystemOn" ] ],
|
|---|
| 823 | [ "AGILENT_CONTROL", [ "VoltageOn" ] ],
|
|---|
| 824 | [ "BIAS_CONTROL", [ "VoltageOff", "VoltageOn", "Ramping" ] ],
|
|---|
| 825 | [ "FEEDBACK", [ "CurrentCtrlIdle", "CurrentControl" ] ],
|
|---|
| 826 | [ "RATE_SCAN", [ "Connected" ] ],
|
|---|
| 827 | [ "RATE_CONTROL", [ "Connected", "InProgress" ] ],
|
|---|
| 828 | [ "LID_CONTROL", [ "Open", "Closed" ] ],
|
|---|
| 829 | [ "DRIVE_CONTROL", [ "Armed", "Tracking", "OnTrack" ] ],
|
|---|
| 830 | [ "FTM_CONTROL", [ "Idle", "TriggerOn" ] ],
|
|---|
| 831 | [ "FAD_CONTROL", [ "Connected", "WritingData" ] ],
|
|---|
| 832 | ];
|
|---|
| 833 |
|
|---|
| 834 | if (!checkStates(table))
|
|---|
| 835 | {
|
|---|
| 836 | //dim.alarm("System inconsistent");
|
|---|
| 837 | //dim.alarm();
|
|---|
| 838 | throw new Error("Something unexpected has happened. One of the servers "+
|
|---|
| 839 | "is in a state in which it should not be. Please, "+
|
|---|
| 840 | "try to find out what happened...");
|
|---|
| 841 | }
|
|---|
| 842 |
|
|---|
| 843 | // ------------------------------------------------------------
|
|---|
| 844 |
|
|---|
| 845 | console.out(" Run #"+run+" (remaining "+parseInt(remaining)+"min)");
|
|---|
| 846 |
|
|---|
| 847 | // ----- Time since last DRS Calibration [min] ------
|
|---|
| 848 | var runs = service_drs.get(0);
|
|---|
| 849 | var diff = (new Date()-runs.time)/60000;
|
|---|
| 850 |
|
|---|
| 851 | // Warning: 'roi=300' is a number which is not intrisically fixed
|
|---|
| 852 | // but can change depending on the taste of the observers
|
|---|
| 853 | var valid = runs.obj['run'][2]>0 && runs.obj['roi']==300;
|
|---|
| 854 |
|
|---|
| 855 | if (valid)
|
|---|
| 856 | console.out(" Last DRS calib: %.1fmin ago".$(diff));
|
|---|
| 857 | else
|
|---|
| 858 | console.out(" No valid drs calibration");
|
|---|
| 859 |
|
|---|
| 860 | // Changine pointing position and take calibration...
|
|---|
| 861 | // ...every four runs (every ~20min)
|
|---|
| 862 | // ...if at least ten minutes of observation time are left
|
|---|
| 863 | // ...if this is the first run on the source
|
|---|
| 864 | var point = (run%4==0 && remaining>10) || run==0;
|
|---|
| 865 |
|
|---|
| 866 | // Take DRS Calib...
|
|---|
| 867 | // ...every four runs (every ~20min)
|
|---|
| 868 | // ...at last every two hours
|
|---|
| 869 | // ...when DRS temperature has changed by more than 2deg (?)
|
|---|
| 870 | // ...when more than 15min of observation are left
|
|---|
| 871 | // ...no drs calibration was done yet
|
|---|
| 872 | var drscal = (run%4==0 && (remaining>15 && diff>70)) || !valid;
|
|---|
| 873 |
|
|---|
| 874 | if (point)
|
|---|
| 875 | {
|
|---|
| 876 | // Change wobble position every four runs,
|
|---|
| 877 | // start with alternating wobble positions each day
|
|---|
| 878 | var wobble = (parseInt(run/4) + parseInt(new Date()/1000/3600/24-0.5))%2;
|
|---|
| 879 |
|
|---|
| 880 | //console.out(" Move telescope to '"+source+"' "+offset+" "+wobble);
|
|---|
| 881 | console.out(" Move telescope to '"+obs[sub].source+"' ["+wobble+"]");
|
|---|
| 882 |
|
|---|
| 883 | //var offset = observations[obs][2];
|
|---|
| 884 | //var wobble = observations[obs][3 + parseInt(run/4)%2];
|
|---|
| 885 |
|
|---|
| 886 | //dim.send("DRIVE_CONTROL/TRACK_SOURCE", offset, wobble, source);
|
|---|
| 887 |
|
|---|
| 888 | dim.send("DRIVE_CONTROL/TRACK_WOBBLE", wobble+1, obs[sub].source);
|
|---|
| 889 |
|
|---|
| 890 | // Do we have to check if the telescope is really moving?
|
|---|
| 891 | // We can cross-check the SOURCE service later
|
|---|
| 892 | }
|
|---|
| 893 |
|
|---|
| 894 | if (drscal)
|
|---|
| 895 | {
|
|---|
| 896 | console.out(" Take DRS calibration.");
|
|---|
| 897 | doDrsCalibration(); // -> VoltageOff
|
|---|
| 898 | }
|
|---|
| 899 |
|
|---|
| 900 | OpenLid();
|
|---|
| 901 |
|
|---|
| 902 | // voltage must be switched on after the lid is open for the
|
|---|
| 903 | // feedback to adapt the voltage properly to the night-sky
|
|---|
| 904 | // background light level.
|
|---|
| 905 | service_feedback.voltageOn();
|
|---|
| 906 |
|
|---|
| 907 | // This is now th right time to wait for th drive to be stable
|
|---|
| 908 | dim.wait("DRIVE_CONTROL", "OnTrack", 150000); // 110s for turning and 30s for stabilizing
|
|---|
| 909 |
|
|---|
| 910 | // Now we have to be prepared for data-taking:
|
|---|
| 911 | // make sure voltage is on
|
|---|
| 912 | service_feedback.waitForVoltageOn();
|
|---|
| 913 |
|
|---|
| 914 | // If pointing had changed, do calibration
|
|---|
| 915 | if (point)
|
|---|
| 916 | {
|
|---|
| 917 | console.out(" Calibration.");
|
|---|
| 918 |
|
|---|
| 919 | // Calibration (2% of 20')
|
|---|
| 920 | while (1)
|
|---|
| 921 | {
|
|---|
| 922 | if (!takeRun("pedestal", 1000)) // 80 Hz -> 10s
|
|---|
| 923 | continue;
|
|---|
| 924 | if (!takeRun("light-pulser-ext", 1000)) // 80 Hz -> 10s
|
|---|
| 925 | continue;
|
|---|
| 926 | break;
|
|---|
| 927 | }
|
|---|
| 928 | }
|
|---|
| 929 |
|
|---|
| 930 | console.out(" Taking data: start [5min]");
|
|---|
| 931 |
|
|---|
| 932 | var len = 300;
|
|---|
| 933 | while (len>0)
|
|---|
| 934 | {
|
|---|
| 935 | var time = new Date();
|
|---|
| 936 | if (takeRun("data", -1, len)) // Take data (5min)
|
|---|
| 937 | break;
|
|---|
| 938 |
|
|---|
| 939 | len -= parseInt((new Date()-time)/1000);
|
|---|
| 940 | }
|
|---|
| 941 |
|
|---|
| 942 | console.out(" Taking data: done");
|
|---|
| 943 | run++;
|
|---|
| 944 | }
|
|---|
| 945 |
|
|---|
| 946 | service_drs.close();
|
|---|