source: trunk/MagicSoft/Mars/NEWS@ 7724

Last change on this file since 7724 was 7720, checked in by tbretz, 19 years ago
*** empty log message ***
File size: 67.3 KB
Line 
1 -*-*- END -*-*-
2
3 *** Version <cvs>
4
5 - merpp: better handling of problems with the TH and TD part of the
6 CC-REPORT for files older than 200507190 and 200412210
7 respectively
8
9 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
10 than one off-source region in wobble-mode. To use it add the following to
11 your ganymed_wobble.rc:
12 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
13 + MHThetaSqN.NumOffSourcePos: 3 (define the number of off-regions)
14 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
15 + Cut1.ThetaCut: None
16 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
17
18
19
20 *** Version 0.9.5.1 (2006/05/05)
21
22 - general: Added a new option "zdiff" to the Makefile which runs
23 "cvs diff" as "make diff" would do, but with compression
24
25 - general: accelerated MTFillMatrix (used for eample in all training
26 and optimization macros) by skipping some obsolete calles in the
27 eventloop the first and second loop could be accelerated by ~20%
28
29 - general: Added a missing feature in the MFilterLIst class which
30 prevented MFEnergySlope from working correctly in trainenergy.C
31
32 - general: Accelerated the random forest training and usage a bit
33
34 - merpp: Adapted to new raw data file format version 6
35
36 - merpp: fixed a problem with reading the starguider reports
37 after 6.3.2006
38
39 - callisto: At some times six pixels had to be exchanged manually in the
40 data. If the pixels to be swaped are both not found, an error was raised
41 and calibration was stopped. Now it is assumed they are intentially not
42 mapped and the Error has been changed to a Warning.
43
44 - star: Added new image cleaning based on the arrival time of the shower.
45 The new cleaning can be accessed using the parameter "Time" instead of
46 the the old one (like "Absolute) in the star.rc-file.
47 Recommended parameters:
48 + MImgCleanStd.CleanLevel1: 8.2
49 + MImgCleanStd.CleanLevel2: 5
50 + MImgCleanStd.CleanRings: 2
51 + MImgCleanStd.KeepSinglePixels: No
52
53 - star: Simplified the calculation of the effective on time. By letting
54 the fit start in the third bin the result should become more stable.
55 The fit quality is now ignored for the theta-plot which is not used
56 in the analysis later. Still better pre-cut which, for example,
57 remove events triggered by car-light (rate changing on a short
58 time-scale) are missing.
59
60 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
61 for optimization (kWeakSource) which is suggested by the Berlin
62 people for weak sources.
63
64 - macros: plotdb.C:
65 + if no dataset and no time-interval is given only sequences with
66 an effective on-time above five minutes are plotted anymore
67 + added a new tab "RelTime" displaying the relative on-time
68 (effective on-time divided by the observation time)
69
70 - macros: optim*.C: by skipping some obsolete calles in the eventloop
71 the optimization became a lot faster
72
73 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
74 To display them just delete the pads displayed on top.
75
76 - ganymed: fixed a bug which could cause strange behaviour in wobble
77 mode if no starguider information was available due to an incorrect
78 initialization of the starguider calibration
79
80 - ganymed: The scale region in the False Source Plot (MHDisp) can now
81 be changed from within the plot. It can also be setup from the
82 resource file using:
83 + MHDisp.fScaleMin: 0.325
84 + MHDisp.fScaleMax: 0.475
85
86 - ganymed, showplot: Fixed a problem with the fit to the off-data
87 (HistOff) which could cause a time lag or an inifinite loop.
88 The bug did not effect the results at all.
89
90 - sponde: Added a new tab showing the effective collection area after
91 trigger (including the software trigger)
92
93 - sponde: MMcSpectrumWeight has a new option which allows to define
94 the scaling factor not by the integral of the events but at
95 a defined energy:
96 e.g. MMcSpectrumWeight.NormEnergy: 200
97
98 - MTFillMatrix, sponde: by skipping some obsolete calles in the
99 eventloops the loop could be accelerated by ~20%
100
101
102
103 *** Version 0.9.5 (2006/03/13)
104
105 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
106 and added the standard Disp-parametrization
107
108 - macros: added a new macro datacenter/macros/plotstat.C allowing
109 to plot statistics about the data processing
110
111 - macros: added a new macro to plot the muon correction coefficients
112 versus period (macros/plot/mucal.C)
113
114 - showplot: path inflation for ganymed files was broken
115
116 - callisto: Fixed an important bug. When the number of saturating pixels
117 were calculated the bad pixel information already available from the
118 calibration was ignored. This yields wrong values in case pixels
119 are broken and saturate all the time or randomly.
120
121 - callisto: Updated Muon calibration constants. Spline data now also uses
122 different values for different periods
123
124 - star: The time-evolution shown in the effective on-time plot now displays
125 the axis range (if there are no holes it should be similar to the
126 effective on-time)
127
128 - star: Added two new image parameters:
129 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
130 the three pixels next to the center of gravity and the size
131 + MNewImagePar.fConcCore: The ratio of the signals of all
132 pixels inside or touching the ellipse and the size
133
134 - ganymed: now stops in requested source isn't found in catalog file
135
136 - ganymed: Many improvements to the phi-plot in wobble mode:
137 + with a template the ideal background is displayed
138 + a possible camera inhomogeneity is taken into account
139 + the anti theta cut is better supported
140 + the phi cut is automatically calculated from the theta cut
141 See the examples in ganymed_wobble.rc for more details.
142
143 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
144 times the bin-width instead of the absolute energy
145
146 - ganymed: New cuts for on/off and wobble mode
147
148 - ganymed: The smearing of the False Source plot has been increased
149 to 0.06
150
151 - ganymed: The starguider calibration can now be changed from the
152 resource file.
153 See the examples in ganymed*.rc for more details.
154
155 - ganymed: added a new option for on-/off-observations
156 MJCut.RandomSourcePosition
157 If switched on the distribution of observation time of the source
158 position in the camera is calculated from the on-data and randomly
159 applied with this distrbution to the off-data.
160
161 - ganymed: by skipping some obsolete calles in the eventloop the
162 first and second loop could be accelerated by ~20%
163
164 - ganymed: The default in ganymed_onoff.rc is now to determin the source
165 position in the off-data randomly according to its distribution in the
166 on-data.
167
168
169
170 *** Version 0.9.4.3 (2006/02/13)
171
172 - general: Fixed a bug in most of the programs which prevented the
173 compile date in the startup message to be displayed
174
175 - general: Simplified program calls. The following abbreviations
176 are now possible:
177 showlog callisto 55599
178 showplot signal 55599
179 star 55599
180 callisto 55999
181 ganymed 2
182 In this cases the corrsponding root-, log-, sequence- or dataset-
183 filename is automatically compiled using the default datacenter
184 paths ("/magic/*")
185
186 - general: Fixed a long outstanding bug which made axis tick marks
187 disappear if MDataFormula was used (eg. abs(x))
188
189 - general: Updated MMath with new functions to calculate the results of
190 a exponential, logarithmic and powerlaw fits analytically.
191
192 - general: Updated some macros with comments:
193 + macros/optim/optimdisp.C
194 + macros/optim/optimenergy.C
195 + macros/optim/optimwobble.C:
196
197 - general: MTFillMatrix (the class to fill one or two MHMatrix from
198 files) now allows adding a pre-cut like in the optimization. E.g. this
199 is useful to perform g/h-separation cuts before training the random
200 forest.
201
202 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
203 correctly assigned in the raw data assignement table. A fix to correct
204 the assignment tabel have been implemented.
205
206 - general: MAstroCatalog now allows rotating of the sky-grid and stars
207 by 90, 180 and 270 deg.
208
209 - general: the macro plotdb.C now allows to highlight sequences belonging
210 to a datset. For more details see the descritions in the macro.
211
212 - StatusDisplay: Fixed the algorithm to calculate the size ratio
213 of the display, it gave wrong results espacially for big sizes.
214 Now the embedded canvas should always have a ratio width/height=3/2.
215 The "Size" options have been updated with values fitting the 3/2
216 size ratio.
217
218 - RanForest:
219 + Updated the random forest classes to support also the
220 regression method implemented by Thomas H.
221 + added new tutorial macro how to train the random forest
222 for energy estimation (macros/optim/rfenergyest.C)
223 + new classes to train the random forest (still in development)
224 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
225 + new tutorial macros for random forest training in macros/train
226 trainenergy.C, traindisp.C, trainseparation.C
227
228 - mars: now allows to setup a cut in the resource file mars.rc to choose
229 the events to be displayed, eg:
230 Cut.Condition: {0} && {1}
231 Cut.0: MHillas.fSize>100
232 Cut.1: MHillas.fSize<900
233
234 - merpp: Made aware of the new .rep format 200510250. This includes
235 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
236 the discriminator thresholds (MCameraTD) and the disciminator
237 delays (MCameraTD). All of them come with the CC report and are therefor
238 written to the CC tree.
239
240 - callisto: fixed a bug in the calculation of the arrival times in
241 the Digital Filter. They were all shifted by the same amount
242 fHiGainFirst. This caused an offset in the order of the position of
243 the left border of the extraction window in the times calculated
244 from high-gain and from low-gain. The bug effected only the absolute
245 arrival times. The bug was there since 30.1.2005.
246
247 - callisto: Changed the ExtractionWindow for the pulse position check
248 such that the camera inhomogeneity becomes as less as possible and
249 comparable to the pulso position check switched off. More details
250 on the study will be given at our result web-page.
251
252 - ganymed: ganymed.rc, ganymed_onoff.rc:
253 changed to new cuts trained with 1ES1218 and Crab-data
254 for maximum sigma*log10(excess)
255
256 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
257 a new option was implemented to estimate Disp (CalcDisp)
258
259 - ganymed: Implemented two new options which allow
260 to overwrite the default path to search for the sequence files
261 --ins=/magic/sequences
262 and where to search for the image data
263 --ind=/magic/data/star
264
265 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
266 dx/dy from the resource file by
267 MSrcPosCorrect.Dx
268 MSrcPosCorrect.Dy
269
270 - ganymed: fixed reading the source catalog. Only as many chars
271 as the requested source name had were compared (If a source
272 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
273 were requested it could happen that the coordinates of
274 "1ES1218" were read) The source coordinates are now printed
275 in addition to its name to the logging output.
276
277 - ganymed: changed the background fit in the case of a ThetaSq function
278 from a polynomial to a exponential, this should give a big improvement
279 for on-only analysis'
280
281 - ganymed/sponde: Calculation of the error of single size-/energy-
282 bins now uses Li/Ma (5) instead of LiMa (17)
283
284 - sponde: Added a plot E^2*dN/dE
285
286 - sponde: The energy estimator plot should now show values like
287 they are commonly used.
288
289 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
290 (a powerlaw with cutoff didn't work before)
291
292
293
294 *** Version 0.9.4.2 (2005/10/01)
295
296 - general: added new tutorial macro macros/tutorials/threshold.C:
297 how to calculate the threshold
298
299 - general: added a new game. Start it from the interpreter with
300 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
301 and MagicReversi)
302
303 - general: neighbor pixels in MGeoms are now sorted clockwise
304
305 - merpp: made aware of new format 20050829-0
306
307 - callisto: New scale factors from muon analysis, stored in new
308 resource file resources/calibration.rc
309
310 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
311 the eventloop if something went wrong. This is necessary for the
312 automatic processing
313
314 - callisto: Implemented a new treatment for the time information
315 developed by S.Ruegamer, this should give much better response than
316 the old very primitive algorithm. This is especially important
317 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
318 treatment was buggy! As neighbor pixels to interpolate the
319 arrival times always the pixels 0 to 5 were taken)
320
321 - callisto: In addition to the new treatment of arrival times the
322 decision of the treatment whether a pixel contains shower
323 information or not is used to improve the signal interpolation
324 further. Previously interpolated pixels showed a non-zero signal
325 do the peak searching signal extractors. Having a signal pixel
326 beside raised the signal above the cleaning level. Thus the
327 pixel survived cleaning to often but with a too low mean signal.
328 By replacing empty pixels with a gaus (mean and rms from the
329 corresponding Area entries in MPedPhotCam) this effect can
330 be supressed.
331
332 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
333 got lost when the events were stored by the calibration... fixed.
334 (This was no problem for normal image cleaning because the pixel
335 content was artificially set to 0 not surviving standard cleaning
336 algorithm)
337
338 - callisto: Fixed a bug which caused the random and peak-search pedestal
339 extracted with an extractor to be exchanged for the first (roughly)
340 500 events (*Extractor and *ExtractorRndm).
341 (They were simply exchanged in callisto.cc) This bug might have been
342 introduced in Mars 0.9.4 when the order of calculation of the two
343 types of pedestal in callisto got exchanged. The bug only effects
344 the first seconds of data of each sequence.
345
346 - star: Taking the arrival time of Muons into account the calculation
347 of the parameters could be made independant of the noise
348 (pedestal rms). The dependance was due to the bias of the peak search
349 extractor. Now only a ZA dependamcy is left which is not yet fully
350 understood.
351
352 - ganymed: The sequences were still not sorted correctly in any case,
353 because they were sorted by the full qualified path name. Now they
354 are sorted by their sequence number.
355
356 - ganymed: new values for the spark-event-cut
357
358 - sponde: required missing MEnergyEst from ganymed.root... fixed.
359
360
361
362 *** Version 0.9.4.1 (2005/08/18)
363
364 - callisto: fixed some problems with the calibration in case of
365 inteleaved events. Therefor the final and some intermediate
366 fits are skipped which would take place on partly filled #
367 histograms and gave wrong results or failed completely.
368
369 - callisto: If the intermediate finalization of the histograms
370 calculating the mean charge of the calibration signal fails
371 it is counted now and printed in PostProcess of MCalibCalcFromPast.
372
373 - ganymed: Fixed some bugs which caused problems in On-only mode.
374 Still the false source plot doesn't give reasonable results.
375
376
377
378 *** Version 0.9.4 (2005/08/05)
379
380 - general: Fixed the ZA binning. It did not correctly fit the
381 MC binning
382
383 - general: Added a class to correct for the missfocussing in
384 April (MSrcPosCorrect)
385
386 - general: Random Forest energy estimator should now work properly
387
388 - general: MHCamera now displays the profiles in deg instead of mm
389
390 - general: MH::SetPalette offers a lot of new palettes
391
392 - general: MHillas - the case of CorrXY==0 is now handled properly
393
394 - general: implemented the possibility to change the line and
395 marker style of a sky-grid drawn by MAstroCatalog
396
397 - general: Runs in sequences and datasets are now automatically
398 ordered (it is assumed that the order of their filenames correctly
399 represents the order of observations) to ensure correct reading
400 of the subsystem data
401
402 - general: Runs cannot be added to a sequence twice anymore. Also
403 Sequences cannot be added twice anymore to a dataset.
404
405 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
406 It gave wrong results by 1./2pi
407
408 - showplot: got a new option to start a root interpreter, too
409
410 - mars: now displays a rough estimate of Disp and the third moment
411
412 - mars: now displays the event time MTime if available
413
414 - mars: show muon parameters graphically
415
416 - mars: now the file to open can be given as commandline
417 argument
418
419 - merpp: Added support for new arehucas version >= 200507190
420 implementing values for three temperature sensors in the
421 counting house (MCameraAUX) and the name of the HV settings file
422 (MCameraHV).
423
424 - merrp: Also fixed some problems with wrong versions numbers stated
425 by arehucas and implemented some fixed for old versions (<200407070)
426
427 - callisto: MCalibrationHiLoCam can now be printed from its context
428 menu, eg in the TBrowser
429
430 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
431 - 1.39 (MExtractTimeAndChargeSpline)
432 - 1.40 (MExtractTimeAndChargeDigitalFilter)
433 This is important mainly for timing studies.
434
435 - callisto: Changed limits in MHCalibrationChargeCalc from
436 - -100.125 to -98 (fgChargeHiGainFirst)
437 - 1899.875 to 1902. (fgChargeHiGainLast)
438 - -100.25 to -99 (fgChargeLoGainFirst)
439 - 899.75 to 901. (fgChargeLoGainLast)
440 Introduced new limits:
441 - fgNumLoGainBlackoutLimit: 0.05
442 - fgLoGainBlackoutLimit: 3.5
443 - fgLoGainPickupLimit: 3.5
444
445 - callisto: The handling of automatic weights for the digital filter
446 has been improved. There are now new calibration weights special
447 for Monte Carlo calibrations.
448
449 - callisto: Updated Muon scale with latest results (1% difference
450 for most data, 5% for Mar/Apr'05)
451
452 - callisto: use a new criterium to exclude bad pixels: If the high-gain
453 was saturated and the blackout-events in the low-gain exceed the
454 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
455 This excludes those pixels which have a saturating high-gain
456 channel, but the low-gain switch does not switch often enough
457 to make the distribution reliable.
458
459 - callisto: fix a bug counting the number of saturated events. Up to now,
460 the number of saturated slices was counted (which is one for a not too
461 high number), but for some (pathological) pixels, many more slices
462 saturated and produced wrong limits.
463
464 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
465 + MCalibrationRelTimeCam.CheckFitResults: Yes
466 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
467 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
468 + MCalibrationRelTimeCam.CheckOscillations: Yes
469
470 - callisto: introduce max. number of events for intercalibration,
471 the rest gets skipped. Default: 4096
472 The calibration causes too many un-reliable pixels if more
473 than about 5000 events are treated (@500 Hz) because of the
474 mode hopping of the VCSels. However, in the past, some
475 calibration runs have been taken (erroneously) with more
476 than 5000 events, especially the intensity scans where
477 a good precision is needed.
478
479 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
480 photo-electrons for the spline extractor by 1-2% (correctly).
481
482 - callisto: The intercalibration is now done using a full f-factor
483 method instead of a simple update. This makes things slower but
484 more reliable in terms of gain-fluctuations and sudden VCSEL gain
485 changes.
486
487 - callisto: MPedestalY3 now uses the same extraction range as the data
488 as calculated by MPedestalY2
489
490 - callisto: A check of the fraction of allowed unsuitable (10%) and
491 unreliable (30%) pixels has been addded when the conversion is
492 calculated from interleaved events
493
494 - star: fixed a bug which caused MEffectiveOnTime containers not to
495 be written. In the worst case they were skipped almost all, in the
496 best case they were all ok. It depends on how often the new value
497 was assigned just with an event which was skipped later by another
498 task
499
500 - star: new histograms MHPointing and MHRate
501
502 - star: New tab (Currents) displaying the time evolution of the mean
503 DC currents
504
505 - star: New tab (MeanRms) displaying the time volution of the mean
506 Pedestal Rms
507
508 - star: Output now contains MReportStarguider
509
510 - star: Improved muon analysis. Due to the absense of a constant
511 for the gaus fit for arc width and the fact that the arcwidth
512 plot was a histogram instead of a profile the resulting psf
513 became pedestal rms dependant
514
515 - ganymed: added new plot (MHPhi) for wobble mode as described in
516 http://www.astro.uni-wuerzburg.de/results/ringmethod/
517
518 - ganymed: corrects now (correctly?) for the misspointing in
519 May/April 05
520
521 - ganymed: Two new default templates for ganymed.rc are avilable:
522 ganymed_onoff.rc and ganymed_wobble.rc
523
524 - ganymed: The first version of MFMagicCuts has been released
525
526 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
527
528 - ganymed, sponde: There are two new options to determin the number
529 of bins for the signal region (NumBinsSignal) and the number of
530 total bins (NumBinsTotal) in the MHThetaSq histogram
531
532 - ganymed: optimized palettes for MHDisp
533
534 - ganymed: Fixed an important bug when using ThetaSq as fit function:
535 The result for the sigma of the gauss(sqrt(x)) fit was a factor
536 sqrt(2) to large
537
538 - ganymed: The false source plot (MHDisp) is now based on Disp
539 and a background model determined in the first loop is
540 subtracted
541
542 - ganymed: MFMagicCuts are now available in the cvs. The correct
543 solution for the disp ambiguity problem is now calculated using
544 the third moment. The third moment cut therefor is skipped.
545
546 - ganymed: Output now contains "Disp [MParameterD]" which sign is
547 already determined by the third moment along the major axis and
548 so its actual sign is aligned along the major axis of the shower.
549
550 - ganymed: If starguider data is available it is taken into account
551 when calculating the source position. This is especially important
552 for wobble data at high zenith angles and culmination data.
553
554 - ganymed: If available the starguider data is taken into account as
555 good as it is possible without a starguider calibration. To switch
556 it off add
557 MPointingDevCalc.MaxAbsDev: -1
558 to your ganymed.rc
559
560 - sponde: the zenith angle distribution is now weighted instead of
561 choosen by default. This gurantees higher statistics in the highest
562 and lowest energy bins. To switch this behaviour off use...
563
564 - sponde: now automatically displays the energy threshold
565
566
567
568 *** Version 0.9.3 (2005/06/03)
569
570 - general: MMcEvt now derived from MMcEvtBasic which should
571 have no influence on compatibility with older camera files
572
573 - general: Implemented a new option to MReadReports which allows
574 to force reading of the first event of some trees (eg. Drive-tree)
575 before any other tree.
576
577 - general: Made a fix to MPointingPosCalc which assumes that the
578 run-type is real-data if Process is called before ReInit, such
579 that also the very first Drive-events in a run are treated
580 correctly.
581
582 - shoplot now displays the filename in the title bar of the window
583
584 - merpp: new options: --auto-time-start --auto-time-stop which
585 allow to cut updating with slow-control at the start- or
586 (previousle --auto-time only allowed: and) stop-time of
587 the run stored in the runheader.
588
589 - callisto: changed default of fgFallTimeHiGain in
590 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
591 already set as default in callisto_Dec04Jan05.rc
592
593 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
594 now changes the filename for new weights automatically for
595 cosmics, MC and for different calibration colors.
596
597 - callisto: a problem with the order of some code cause the
598 name of the weights file in MPedestalY2 to be ignored.
599 Wrongly the calibration_UV weights were used instead
600 of the cosmics weights set in callisto.rc.
601
602 - callisto: should allow ct1 pulser data when the color is
603 explicitly set also for pretty new runs
604
605 - callisto: a new option (MCalibrateData.ScaleFactor) allows
606 to introduce an additional scale factor (should be around 1)
607 to adapt for slight deviations in different extractors from
608 the MC calibration. For MC calibrations the scale factor
609 is fixed to 1
610
611 - callisto: MFCosmics should handle very high signals a bit
612 more accurate now
613
614 - callisto: when calculating the mean pedestal rms for different
615 pixel sizes or sectors also kUnsuitableEvt is now taken into
616 account - not only kUnsuitableRun
617
618 - callisto: '-raw' option is now the default
619
620 - callisto: A dead pixel check has been implemented in MJPedestalC2.
621 This has the advantage that mean values in the calibration (eg
622 arrival times) are calculated more accuratly.
623
624 - callisto: In the resource file callisto_Dec04Jan05.rc
625 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
626
627 - callisto: new Hi-/Lo-Gain intercalibration constants
628 hilocalib_sp1.root and hilocalib_sp1_mc.root
629
630 - callisto: changed default for MJPedestalY2.MaxEvents
631 from 2000 to 5000 like in callisto_Dec04Jan05.txt
632
633 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
634 has changed from 9.0 to 6.0. This is necessary to exclude two very
635 ringing pixels in September which - when kept - destroy the image
636 cleaning around them (Markus G.)
637
638 - callisto: (!) The Muon analysis of all data taken so far has
639 suggested that different extractors give slightly different
640 absolute results after calibration, due to there different
641 handling of the calibration- and cosmics pulse shape. Although
642 the over all calibration seems to be a bit to pesimistic (or
643 the MC seems to be a little bit - 3-5% - too much attenuated).
644 There for correction factors have been introduced which correct
645 the calibration constants by
646 0.956937799 for Digital Filter (callisto.rc)
647 and
648 0.904159132 for Spline (callisto_Dec04Jan05.rc)
649 calibration. The main advantage is, that both data types can
650 be easily analysed together and compared to the same MC sample.
651 The factors are choosen such, that the reference is now a
652 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
653
654 - star: fixed a bug which caused the first bin of the histograms
655 vs time to disapear in PostProcess. This gave wrong results
656 on the screen. The output and all following programs not
657 directly accessing the histograms haven't been affected
658
659 - star, ganymed: Made sure that always the first Drive-tree event
660 is read and Processed before the first data event was read.
661
662 - ganymed: implemented the possibility to replace the standard
663 false source plot with a different one. For example: If
664 you want to use a Disp based FS plot use the resource:
665 NameHistFS: MHDisp
666 For details about the requirements of these plots look
667 at the corresponding classes
668
669 - MJOptimize: For On/Off and Wobble optimization MJOptimize
670 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
671 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
672 case MAlphaFitter is setup correctly. For On-Only optimization
673 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
674 RunOn() instead of Run(). For energy estimation MJOptimize
675 has been replaced by MJOptimizeEnergy
676
677 - sponde: The input MC spectrum can now be weighted to fake a
678 different spectrum. This is done via MMcSpectrumWeight. For
679 more details see the class description and sponde.rc
680
681 - sponde: The paremeter comparsion plots are not scaled by
682 their entries anymore. Instead the MC plot is scaled by using
683 the result spectrum of the analysis. If the input MC spectrum
684 and the result spectrum has different slopes the absolut
685 normalization is normally wrong.
686
687
688
689 *** Version 0.9.2 (2005/05/20)
690
691 - general: Changed the default paths for calibrated data and image
692 files. (The implemented access to these files doesn't yet exist)
693
694 - general: support for MRunIter has been removed from the job classes
695 (use the setter functions of MSeqeunce instead)
696
697 - general: ProcessFile has been renamed to Process in all job classes,
698 because ProcessFile is missleading
699
700 - general: The storage of the palette in MHCamera is now possible
701
702 - general: new bits describing unsuitable and unreliable pixels have
703 been introduced in MBadPixelsPix: kPreviouslyExcluded,
704 kDeadPedestalRms, kFluctuatingArrivalTimes
705
706 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
707 versions newer than V200404070
708
709 - general: support for cc file versions newer than V200504130. Added
710 support for active loads (MCameraActiveLoad) and central pixel
711 (MCameraCentralPixel)
712
713 - general: added new histograms for image parameters versus size
714 (MHVsSize)
715
716 - general: The eventloop now automatically calls PrintStatistics
717
718 - Status Display: Improved support for printing:
719 + A default can now be set in .rootrc (for more details see
720 MStatusDisplay::PrintPS)
721 + A print dialog is opened so that printer and command line
722 can be canged
723
724 - showlog: improved such that it handles different verbosity levels
725 more accurate now. This mean you can suppress output when
726 using showlog.
727
728 - showplot: improved
729 + The new graphics formats have been implemented
730 (pdf, svg, png, jpg and xpm)
731 + Implemented an interface for printing. Because you can change
732 the printing command from the command line you can use all
733 the nice postscript tool. To print a booklet for example call:
734 showplot -b --print --print-cmd="cat %f" filename.root | lpr
735 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
736 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
737
738 - callisto: fixed a bug in the recognition of the calibration bit
739 pattern. Concerns only intensity calibration. (The strength of the
740 intensity has been updated in some cases)
741
742 - callisto: add a filter against PIN Diode events when running over
743 calibration runs since some of the recent calibration runs have
744 been taken with Pin Diode.
745
746 - callisto: added support for the runs 39942, 39944, 44834, 39941,
747 39943, 44833 in the calibration (MCalibColorSet)
748
749 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
750 been set to 1e-18 in callisto_Dec04_Jan05.rc
751
752 - callisto: in callisto_Dec04Jan05.rc: set value for
753 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
754 statistics for the calculation of the mean pulse time
755 of the cosmisc
756
757 - callisto: the charge limit in the calibration has been raised
758 from 2.5 to 4.5
759
760 - callisto: new setup read from callisto.rc
761 + MCalibCalcFromPast.fNumEventsDump
762 + MHCalibrationChargeCam.NumHiGainSaturationLimit
763 + MHCalibrationChargeCam.NumLoGainSaturationLimit
764
765 - callisto: MExtractTimeAndChargeSpline extractor:
766 + The integration ranges were shifted by 0.2 FADC slices to the right.
767 + unreliable handling of floating point values caused different
768 results on different platform or with different compiler options:
769 The new algorithm is numerically exact and more accurate because
770 it doesn't calculate the integration position by multiple times
771 adding the step-size (which results in numerical uncertanties
772 exspecially if multiplied with large numbers)
773 + A lot of fixes have been introduced which effects integrating the
774 spline at the edges of the valid range. In this case any memory
775 was randomly accessed. This behaviour can be tested replacing
776 all MArrayF by TArrayF which perform a range check (but of course
777 they are a lot slower)
778 ! No result obtained with the Spline before can be trusted! Due to
779 random memory access it might by completely random!
780
781 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
782 + extraction range in the high gain to 4.
783 + weights file to cosmics_weights46.dat
784
785 - callisto:
786 + introduce the check for fluctuating arrival times.
787 + set charge limit to from 2.5 to 4.5
788 + introduce asymmetric exclusion due to "deviating number of phes":
789 Default: -9.0 +4.5
790 + make deviating number of phes unsuitable (see David's findings).
791
792 - callisto: fixed the display of unsuitable pixels. The old change
793 to a real profile in MHCamera broke it.
794
795 - callisto: The cosmics filter is used in MJCalibration now
796 independant of the pulser color (formaly it was used only for
797 CT1-pulser data). The threshold of number of max empty pixels
798 has been raised from 2% to 5% in MJCalibration. The maximum
799 fraction of rejected event is 50% otherwise the calibration has
800 failed. The filter now ignores unsuitable pixels.
801 Setup the filter from callisto.rc using "ContCosmics"
802 (see MFCosmics::ReadEnv)
803
804 - callisto: changed default for fgOffsetFromLogain back
805 from -2.8 to -1.8 in digital filter.
806
807 - callisto: for the common extractors
808 + MExtractFixedWindow
809 * MExtractTimeAndChargeSlidingWindow
810 * MExtractTimeAndChargeSpline
811 * MExtractTimeAndChargeDigitalFilter
812 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
813 and fResolutionPerPheLoGain
814
815 - callisto: Updated the hi-/lo-gain intercalibration constants
816 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
817 hilocalib_df6.root
818
819 - callisto: The default lo-gain extraction window for the
820 MExtractTimeAndChargeSlidingWindow extractor has been increased
821 from 6 to 8 to take the stretch of the pusle into account
822
823 - callisto (!!!): fixed an important bug in the setting of the
824 incoming pedestal pointer to the signal extractor extracting
825 pedestals. This bug caused the pedestals not to be subtracted
826 correctly in the calibration afterwards. The effect was about 10%
827 too high conversion factors for the digital filter and the spline
828 and more than 40% for the sliding window.
829 The bug existed since end of February! (Markus G.)
830
831 - star: added muon support to star. A new tab "MHMuonPar" is
832 displayed. The lower right plot is an estimate of the point spread
833 function. A reference value is displayed. To get the real PSF
834 you must compare with MC. The setup for the muon analysis
835 is done in star.rc. More informations can be found in
836 MHSingleMuon and MHCalibParCalc
837
838 - star: The weather data is now displayed in star
839
840 - star: MEventRateCalc handles the calculation of the event rate more
841 accurate now in case of the start of a new run inside a sequence
842
843 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
844 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
845 changed only minimally
846
847 - ganymed: (MJCut and MJOptimize) now displayes the number of
848 excess events versus size. The energy estimation is done in
849 MJSpectrum (sponde)
850
851 - ganymed: got support for using other variables than Alpha, eg. Theta.
852 Therefor you need a class deriving from MHAlpha which supports
853 this variable (one is already existing: MHTheta, which is now the
854 default in ganymed). It is setup through ganymed.rc
855
856 - added a full featured spectrum program (sponde) which reads
857 ganymed output and monte carlos and compiles a spectrum
858
859
860
861 *** Version 0.9.1 (2005/04/14)
862
863 - Fix bug on the arrival time reconstruction when using Digital
864 Filter (in some marginal cases (10%) times were reconstructed shifted
865 by 0.2 slices)
866
867 - all executables now return 2 where in previous versions -1 has
868 been returned (gave problems with shell-scripts)
869
870 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
871 also done with a intercalibration input file
872
873 - a bug in the time fine adjustment of the digital filter has been fixed
874
875 - a lot of small fixes to calling TPad::Divide with a margin==0
876
877 - MStatusDisplay now shows the memory usage
878
879 - added a memory leak statistic after the eventloop
880
881 - MHadronness replaced by MParameterD
882
883 - MEnergyEst replaced by MParameterD
884
885 - wobble mode can now be switched on from the data-set
886
887 - switched on bad pixel detection for a pedestal level
888 which is more than 5 times the variance
889
890 - Fixed default paths to be correct for the new data center
891
892 - Fixed handling of drive data. The pointing position in now
893 copied to MPointingPos inside star for real and MC events
894
895 - made sure, that the sequences in a dataset are sorted by
896 their number to ensure the correct synchronization
897
898 - added all resource files necessary to handle spline extraction
899 of signal for the late 2004 and the early 2005 data
900
901 - update the reference lines for the december data
902
903 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
904 This is important for the Dec. and Jan. data where the calibration
905 pulse position changes much.
906
907 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
908 filter. This corrects only an defective extraction of the MC at
909 low-gain signals lower than 90 phes.
910
911 - fixed some slowdown in calibrating data with interleaved events from
912 Jan and Dec. As a workaround made the pretty palette the default.
913 The inverse Deep Blue Sea has a bug which slows down long calibration
914 runs a lot.
915
916 - implemented new values from new starguider report as defined
917 in TDAS00-07 V7.1 (eg SkyBrighness)
918
919 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
920 in starguider report (If you merpp the same reports with this version
921 you'll get the correct units (arcmin) but a different result
922 than with old versions (wrong units))
923
924 - Now the status display can also write PNG, JPEG and XPM (other file
925 formats are still unsupported by root)
926
927 - added a lot of scripts and macros in directory datacenter used
928 for automatic processing
929
930
931
932 *** Version 0.9 (2005/03/23)
933
934 - Calibration is now done autmatically into photo-electrons like
935 decided by the Collaboration Board
936
937 - Reference lines in the display can be read from resource file
938
939 - Interlaced calibration events can be handled by callisto
940
941 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
942 and applied in callisto.
943
944 - class MJCalibTest can be called by callisto
945
946 - callisto can now run with three data types: rawdata, rootdata, MC
947
948 - added two classes mreport/MReportStarguider.cc and
949 mreport/MReportStarguider.h for implementing starguider-data
950
951 - the output of merpp-update now contains starguider information:
952 MReportStarguider and MTimeStarguider
953
954 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
955 values were lower than they should. This was more visible for high
956 energy (Size) events.
957
958 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
959
960 - added a new loop to callisto to support the correct extraction of
961 the pedestal and pedestal rms through the signal extractor
962
963 - added class to perform fourier tranformation of a hexagonal structure
964 (MHexagonalFT)
965
966 - added class to perform fourier tranformation of a hexagonal structure
967 in a tasklist (MHexagonalFTCalc) example: hft.C
968
969 - added class to enhance the MCerPhotEvt from the Magic camera geometry
970 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
971 small pixels, example: extendcam.C
972
973 - added possibility to write data to memory (TTree) using MWriteRootFile
974
975 - added possibility to read a TTree stored only in memory by MReadTree
976
977 - new classes to deal with the interleaved calibration events:
978 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
979
980 - implemented filters to callisto to skip calibration events
981
982 - changed callisto to calculate three kinds of pedestals and pedestal rms:
983 + fundamental pedestal (MPedPhotFundamental): extracted directly from
984 the slices by statistics
985 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
986 signal extractor without randomization
987 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
988 with the signal extractor with randomization (extraction window is
989 randomly fixed)
990 The three kind of pedestal is not yet implemented (for speed reasons) as
991 long as nobody really needs it:
992 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
993 extracted with the signal extractor with randomization
994
995 - callisto now finds the pulse position in the data automatically
996
997 - implemented data reduction in calibrated data by reducing the precision
998 of the stored floating point values (pedestal, rms and signal) to
999 roughly 0.5%
1000
1001 - fixed showplot to make file format conversion (eg. converting a
1002 status display stored in a root file into a postscript file) in
1003 batch mode possible:
1004 showplot -b --save-as-ps[=outfile.ps] infile.root
1005
1006 - Allow class names as part of filter rules, eg
1007 (MFSupercuts) && (MHillas.fSize>100)
1008
1009 - fixed a lot of stuff to allow all programs to process MonteCarlo
1010 camera files.
1011
1012 - enhanced possibility to debug reading of resource file
1013
1014 - MDataChain should handle priorities of operator more
1015 accurate now
1016
1017 - completely revised the container in which the signal is stored
1018 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1019 * the new implementation is faster and
1020 * needs less storage space
1021
1022 - FIRST version which can process Monte Carlos through the
1023 whole chain of programs (callisto, star, etc)
1024
1025 - implemented new image parameters for the border length of
1026 the shower image (MNewImagePar2)
1027
1028 - implemented wobble-mode in ganymed
1029
1030 - new class (MJOptimize) taking care of all optimization processes
1031
1032
1033
1034 *** Version 0.8.6 (2004/10/05)
1035
1036 - New combined signal and time extractor
1037 MExtractTimeAndChargeDigitalFilter
1038
1039 - The Report for the trigger section in the CC run summary has been
1040 updated, and now the IPRs (Individual Pixel Rates) are available.
1041
1042 - new macros for database interaction: filldotrun.C, filldotrbk.C
1043
1044 - added new program which can convert colored output which was redirected
1045 into a file back into colored text (for example to display it with
1046 more): showlog
1047
1048 - added new program to display an MStatusArray of plots (stored with
1049 MStatusDisplay) from a file: showplot
1050
1051 - Added support for Sequences (MSequence). Sequences are blocks of run
1052 files containing the same calibration and belonging to the same
1053 source
1054
1055 - Added a new task (MTaskEnv) which can be used in setup files to switch
1056 between different tasks (for example to choose a signal extractor)
1057
1058 - Implemented automatic file splitting in MWriteRootFile
1059
1060 - After image cleaning an island index is assigned to all used pixels.
1061 The index corresponds to the order of the islands in size.
1062
1063 - added a cleaning which takes signal height _and_ arrival time into
1064 account: probability cleaning (for more details see MImgCleanStd)
1065
1066 - added a cleaning which takes takes the absolute number of photons
1067 times the area ratio as cleaning level
1068 (for more details see MImgCleanStd)
1069
1070 - Changed calculation of image parameters such, that it can be done
1071 for all used pixels or the pixels with a defined island index only
1072
1073 - implemented new image parameters displaying the number of islands,
1074 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1075
1076 - event display in executable changed to support also calibrated files
1077 (done with MJCalibrateSignal)
1078
1079 - added program doing the calibration and the signal extraction
1080 and signal calibration: callisto Most part of the setup is done
1081 by a resource file: callisto.rc
1082
1083 - implemented support for pixels with negative IDs (Raw file format
1084 version 4)
1085
1086 - implemented an new option in merpp (--auto-time) to get the time
1087 range for cc and/or caco data from the run header of the raw data
1088
1089 - New star-program (star and MJStar). Taking calibrated data from
1090 callisto/MJCalibrateSignal as input. The setup is done through
1091 a resource file: star.rc
1092
1093 - Added possibility to setup the eventloop in the mars-executable
1094 Camera Display by a resource file: mars.rc
1095
1096 - The the mars-executable Camera Display can now also read
1097 calibrated data files written by callisto/MJCalibrateSignal
1098
1099 - Added a new class which can calculate the source position in
1100 the camera from a pointing model known to be correct and
1101 the pointing model used for observations (MSrcPosFromModel)
1102
1103 - added a new version of the class calculating the effective on-time
1104 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1105 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1106 MHTimeDiffTheta.
1107
1108 - added the possibility to count how often a signal is above (or
1109 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1110 can replace MHTriggerLvl0)
1111
1112 - added ore convinient ways to set the axis-titles of your histograms
1113 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1114 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1115
1116
1117
1118 *** Version 0.8.5 (2004/08/06)
1119
1120 - new Signal Extractors: MExtractFixedWindowSpline
1121 and MExtractAmplitudeSpline
1122
1123 - implementes interleave in merpp to be able to merpp parts of a file
1124
1125 - implemented force-functionality to merpp
1126
1127 - star display to display star catalogs (MAstroCatalog)
1128
1129 - star display to 'mirror' stars to the camera (MAstroCamera)
1130
1131 - implemented a new cleaning option which allows cleaning scaled with
1132 the real ratio of the rms depending on the pixel size, not only the
1133 square root of the pixelsize (MImgCleanStd, MCameraData)
1134
1135 - removed obsolete MBlind* classes
1136
1137 - Signal extractor taking the AB flag into account implemented (this makes
1138 an odd number of slices for signal extraction possible
1139 (MExtractSignalABcorr)
1140
1141 - implemented a class extracting the pedestal from the raw-data (events)
1142 itself using empty lo-gain (MpedCalcFromLoGain)
1143
1144 - Added mean values to MPedPhotCam
1145
1146 - Added Makefile for Darwin (this OS is NOT officially supported!)
1147
1148
1149
1150 *** Version 0.8.4 (2004/04/19)
1151
1152 - new fast arrival time extractor using cubic splines:
1153 MExtractTimeFastSpline
1154
1155 - implementes multi-argument support in MDataChain
1156 ("pow(a, b)")
1157
1158 - implemented double reference support in MDataChain
1159 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1160
1161 - added support in MF for expressiond like
1162 "MHillas.fWidth<2*<MHillas.fLength"
1163
1164 - MDataChain is now able to support variables like [0], [1], ...
1165 which can be used in fit functions as parameters. The interface
1166 is implemented through the new virtual function
1167 MParContainer::SetVariables
1168
1169 - added new class MArrivalTimeCam/MArrivalTimePix:
1170 Storage containers to hold the ArrivalTime of the camera/pixel
1171
1172 - added new classes for the calibration of relative arrival times:
1173 MCalibrationRelTimePix and MCalibrationRelTimeCam
1174
1175 - added new classes to extract the signal of the blind pixel and the
1176 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1177
1178 - added new classes for the bad-pixels treatment (MBadPixels*)
1179 which are more powerfull than the old ones (MBlindPixel*)
1180 and will replace them.
1181
1182 - added filter against cosmics: MFCosmics
1183
1184 - added new class MArrivalTimeCalc2:
1185 Calculates the arrival time as the signal weighted mean of the time
1186 slices in the maximum window
1187
1188 - added a new macro call pointspreadfucntion.C that fits with a 2D
1189 gaussian the DC spot for an star. It gives you the RMS of
1190 the PSF and the center of the star, very useful for misspointing
1191 studies.
1192
1193 - added support for multi-telescope camera files. Added classes
1194 MStereoCalc and MStereoPar, classes to calculate and store shower
1195 parameters calculated from the data of two telescopes, for the MC
1196 studies regarding the MAGIC clone.
1197
1198 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1199 MC data calibrated in photons instead of ADC counts.
1200
1201 - added three macros to show the calibration and analysis chain of
1202 MC data. The macro starmc.C does both calibration and analysis, producing
1203 an output containing Hillas parameters for each event. The macro
1204 mccalibrate.C does just the calibration and writes out a file containing
1205 pixel information in photons instead of FADC data. The macro starmc2.C
1206 reads in such a file and produces an output with Hillas parameters.
1207
1208 - added MPedPhotCalc to compute pedestals in units of photons, see
1209 macro pedphotcalc.C
1210
1211 - added all class to perform the calibration, see macro calibration.C
1212
1213 - added class MFFT to perform Fast Fourier Transforms
1214
1215 - added class MSimulatedAnnealing to perform simulated annealing
1216 minimizations
1217
1218 - added new macro bootcampstandardanalysis.C which holds the skeleton
1219 of the analysis chain discussed in the december bootcamp.
1220
1221 - added support for DAQ raw data file format V2
1222
1223 - implemented an arbitrary time stamp for the events from raw-data
1224 files with file version<3. It is calculated from the run number,
1225 the date of start and the FADC clock tick from the first module
1226
1227 - implemented the correct decoding of the event time-stamp
1228 coming from the DAQ for raw-data files with file-version>2
1229
1230 - added a new classes storing the pedestals in units of photons:
1231 MPedPhotPix, MPedPhotCam
1232
1233 - added support for DC current files from the camera control
1234
1235 - added support for start- and stop-time when merpping report files
1236
1237 - added MReportCC storing the weather data from the CC-REPORT
1238
1239 - added class to fill trainings and test matrices (MTFillMatrix)
1240
1241 - added a filter performing a software trigger (MFSoftwareTrigger)
1242
1243 - Added classes to perform parts of the standard analysis (Jobs):
1244 + MJPedestals
1245 + MJCalibration
1246 + MJExtractSignal
1247 Note: All of them are preliminary!
1248
1249 - Added Iterator to iterate over files giving only the run-number
1250
1251 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1252 the evolution of a sector vs time
1253
1254
1255
1256 *** Version 0.8.3 (2003/12/05)
1257
1258 - adapted Random Forest classes to allow the use with MC
1259 multi-telescope files which can be produced with the coming
1260 camera version 0.7.
1261
1262 - added classes to read and interprete central control report files
1263 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1264
1265 - enhanced merpp (the executable) to support .raw and .rep files.
1266
1267 - added classes for light calibration (MCalibration* and
1268 MHCalibration*) by Markus Gaug. Further work has to be and will
1269 be done soon.
1270
1271 - Added a preliminary 'synchronizer' (MReadReports) which will
1272 replace MReadMarsFile as soon as it is finished.
1273
1274 - Added a tutorial macro demonstrating how report files are merpped
1275 and how they can be read from the root file in the correct order
1276 of time (readrep.C)
1277
1278 - Added a generalized histogram (similar to MH3) called MVsTime
1279 which allows to plot variables (or rules - MDataChain - of
1280 variables) vs time. For an example have a look at tempvstime.C.
1281
1282 - Changed the name of the event trees:
1283 + Events --> Events
1284 + PedEvents --> Pedestals
1285 + CalEvents --> Calibration
1286
1287 - changed name of MTime in the event trees from MRawEvtTime to MTime
1288
1289 - added displaying the sector indices to the mars event display
1290
1291 - Magic Online Analysis (MOnA) implemented in a first version
1292 (see mona.cc, MOnlineDump and MOnlineDisplay)
1293
1294 - added classes to calculate event rate
1295 (preliminary: MEventRateCalc, MEventRate)
1296
1297 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1298
1299 - added classes dealing with the telescope pointing position (MPointing*)
1300
1301 - implemented the 'final' Mars time stamp based on some experiences with
1302 the new 'Synchonizer'
1303
1304
1305
1306 *** Version 0.8.2 (2003/11/10)
1307
1308 - accelerated standard analysis by a factor of 6-8 ...
1309 + doing precalculations in MGeomCam for the pixel area ratio
1310 + creating a look up table for the single pixels in MCerPhotEvt
1311
1312 - added task to calculates weights in case you want to 'change'
1313 the energy spectrum of a monte carlo file
1314 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1315
1316 - added a new executable star which implements the
1317 star.C macro as precompiled executable. Currently a flexible
1318 setup is not possible, but a 'input card' setup will follow.
1319
1320 - Starting to implement Multi-Telescope-Support based on the
1321 upcomming camera version 0.7. The base for a general support
1322 is implemented and the star-functionality is proven to work.
1323
1324 - Replaced Event-Display in and Camera-Display in the Mars GUI
1325 executable by a more convinient display base on MStatusDisplay.
1326
1327 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1328
1329
1330
1331 *** Version 0.8.1 (2003/10/20)
1332
1333 - added signal subtraction for pure on data by means of fitting
1334 the background in the off region or by performing a combined
1335 signal/background fit. Provides necessary histograms for
1336 obtaining energy spectra and a light curve.
1337
1338 - added classes to perform and study the selection of the
1339 2nd Level Trigger on MC data (example in triglvl2.C macro)
1340
1341 - added pedestal calculation
1342
1343 - implemented "democratic cleaning" (tail cut value proportional
1344 to pixel area) according to Wolfgang's suggestion.
1345
1346 - added Sigmabar treatment (calculation and basic histogramming)
1347
1348 - added basic routines to apply padding
1349
1350 - added first implementation of MARS-based source visibility plotter
1351 (needs to be linked against slalib, preliminary version)
1352
1353 - enhanced functionality of data chains: random numbers, conversion
1354 functions and access to MHMatrix objects
1355
1356 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1357 numbers under certain circumstances (runs with 0 events included)
1358
1359 - fixed a bug in the general filter MF (didn't work on some systems
1360 at all)
1361
1362 - fixed a bug in chaining files, which caused the analysis to crash or
1363 ignore files
1364
1365 - implemented more geometry classes describing the parameters used
1366 to simulate the PMT camera
1367
1368 - added new Monte Carlo classes containing the setup of the different
1369 programs in the MC chain.
1370
1371 - added a (preliminary) general task to evaluate chi-square of a given
1372 parameter in an eventloop.
1373
1374 - first implementation of a container describing the observatory
1375 location (Long, Lat, etc)
1376
1377 - added Random Forest - method for g/h-separation
1378
1379 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1380 (this means, that it is compiling, but not yet fully tested)
1381
1382 - added a new status display which can show the present status
1383 of histograms while an eventloop is running (MStatusDisplay,
1384 an example can be found at status.C)
1385
1386 - reorganized directories:
1387 classes describing the image --> mimage
1388 classes containing Monte Carlo Histograms --> mhistmc
1389 classes for Random Forest method --> mranforest
1390
1391 - added (event-)weights to fill histograms
1392
1393 - colors in logging output to screen
1394
1395 - changes to the Image Parameter declaration:
1396 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1397 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1398 + MHillasExt now derives from MParContainer instead of MHillas
1399 --> Files written with the old definition are more or less unreadable
1400
1401 - reading of reflector files
1402
1403 - display data from reflector files in the camera
1404
1405 - implemented currents (and display them in the camera)
1406
1407 - logarithmic scale in camera
1408
1409 - added class to iterate through directory contents (MDirIter)
1410
1411
1412
1413 *** Version 0.8 (2002/11/18)
1414
1415 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1416
1417 - corrected 48(!) wrong entries in the Next Neighbor table of the
1418 Magic Camera (all in the inner part of the outer ring, mostly
1419 missing a single NN)
1420
1421 - Fixed a bug in the table describing the Next Neighbours of the
1422 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1423 have any neighbour)
1424
1425 - changed trigrate.C: now it calculates the pure NSB triggers from
1426 a camera file (generated with no showers), so there is no need
1427 to introduce them by hand in the BgR array (for more details
1428 please ask Abelardo)
1429
1430 - added MHHadronness (and MHadronness) as a general facility to evaluate
1431 the quality of a gamma-hadron seperation method
1432
1433 - changed MWriteAsciiFile to accept rules (MDataChain)
1434
1435 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1436 must be replaced by calles to MWriteAsciiFile::AddColumn and
1437 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1438 changed.
1439
1440 - Implemented generalized event-matrices (one row per event)
1441 (MHMatrix)
1442
1443 - implemented the one dimensional composite probabilities
1444 (MHCompProb, MCompProbCalc, comprob.C)
1445
1446 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1447 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1448
1449 - Added a camera display displaying the pixel numbers to the
1450 event display gui.
1451
1452 - Added Monte Carlo Informations to event display gui
1453
1454 - Changed the camera display to display the pixel numbering
1455
1456 - Added three buttons to the camera display to change the palette
1457
1458 - Added the number of used and core pixels after image cleaning
1459 to MHillas
1460
1461 - Changed the algorithm used in MHillas according to TDAS 02-03
1462
1463 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1464
1465 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1466
1467 - Added fCosDeltaAlpha to MHillasSrc
1468
1469 - The numbers of photons used to calculate fConc and fConc1 in
1470 MHillasExt are now scaled with the pixel size, so that one get
1471 a four times smaller value for the bigger pixels in the outer ring.
1472
1473 - added new task to smooth the camera contents (MCameraSmooth)
1474
1475 - added possibility to use interpolated pixel values for blind pixels
1476 instead of removing it completely from the analysis
1477
1478 - Implemented the possibility to save the whole eventloop with
1479 its setup to a file. This information can be read and from
1480 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1481 and MEvtLoop::MakeMacro. If you find something not working, please
1482 report - this stuff is still in a beta phase.
1483
1484 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1485 file having crab starfield, but also for all following files - fixed
1486
1487 - MTaskList::PrintStatistics can now be instructud to print also the
1488 title, too: use PrintStatistics(0, kTRUE)
1489
1490 - Changed the image cleaning so that pixels with to many 'used'
1491 neighbors are left used (to get rid of 'holes' in events)
1492
1493 - Introduced more output to the camera displays
1494
1495 - Added an array of histograms (eg one hist per run), MHArray
1496
1497 - Added a _preliminary_ version of the reader for CT1 PreProc files
1498 (MCT1ReadPreProc)
1499
1500 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1501 (thanks to Raquel)
1502
1503 - added the first energy estimator (MEnergyEstParam, estimate.C,
1504 estfit.C) using a parametrization
1505
1506 - Added some new Monte Carlo paremeter containers used to store
1507 setup information from the MC chain (MMcConfigRunHeader,
1508 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1509
1510
1511
1512 *** Version 0.7 (2002/04/30)
1513
1514 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1515 the pedestal mean value was saved incorrectly. For files from
1516 this versions we substract 0.5 from the pedestal mean.
1517 WARNING: This may effect your results, so don't wonder...
1518
1519 - First implementation of an algorithm using only triggered events
1520 for the collection area calculation
1521
1522 - Ascii Output can now also be used for parameter containers which
1523 doesn't overload MParCointainer::AsciiWrite
1524
1525 - The Ascii Output is now also capable of writing single data members
1526 of one container
1527
1528 - You are now able to change the order of the values written to the
1529 ascii file
1530
1531 - You can now specify a conversion factor for each data member written
1532 to an ascii file. This may be usefull to change the units of the
1533 data member (eg. degrees instead of millimeters in case of the
1534 hillas parameters)
1535
1536 - Replaced old MHillas by a new structure which allows you to extend
1537 the parameters stored in MHillas very easily:
1538 see MHillas and MHillasExt
1539
1540 - Added classes to handle source dependancy of image parameters:
1541 see MHillasSrc
1542
1543 - Added container (MBinning) to have a standard input for the binning
1544 in different histograms (eg. the Energy bins should be the same in
1545 all histograms)
1546
1547 - Changed Hillas histograms from mm to deg
1548
1549 - Added the flexible binning to the hillas histograms
1550
1551 - Added a filter for the alpha parameter (MFAlpha)
1552
1553 - It is now possible to write single data members of a class object to
1554 an output stream instead of the whole container only
1555
1556 - Added a generalized filter for a data member:
1557 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1558
1559 - Added a generalized Filter parser for more difficult filter rules
1560 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1561
1562 - Added new Monte Carlo histograms:
1563 MHMcEnergyImpact and MHMcEfficiency
1564
1565 - Added many new histograms needed for the flux calculation.
1566
1567 - Added a generalized histograms which can fill and show up to three
1568 data members in either a one-, two- or three-dimensional histogram, eg:
1569 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1570
1571 - Added:
1572 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1573 * calculation of <Theta> as a function of time (MHThetabarTime)
1574 they are needed in the flux calculation in
1575 order to select for a given bin in Theta (or time) the appropriate
1576 effective collection area, which is assumed to be given as a function
1577 of Theta and the true energy
1578
1579 - Added calculation of the migration matrix in the energy
1580 (MHMcEnergyMigration):
1581 the migration matrix describes the migration from the true (E_true)
1582 to the estimated energy (E_est); it is needed to determine the
1583 distribution of E_true from the measured distribution of E_est
1584 by unfolding
1585
1586 - changed the color palette in the camera display to DeapSea.
1587
1588
1589
1590 *** Version 0.6 (2002/01/15)
1591
1592 - Introduce the option of disable pixels (MBlindPixels and
1593 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1594 able to deal with Star Field NSB.
1595
1596 - Fixed a bug in the pedestals substraction
1597
1598 - Introduced verbosity levels
1599
1600 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1601
1602 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1603 work correctly (thanks to Abelardo)
1604
1605 - Introduced correct treatment of the diffuse Night Sky Background
1606 and NSB (MMcPedestalNSB)
1607
1608 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1609
1610 - Introduced MMcRunHeaders which contains monte carlo run informations
1611
1612 - Added a 'Print'-Task (MPrint) which calls the Print function
1613 of a parameter container for each event
1614
1615 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1616
1617 - changes to be more efficient with root 3.02/06
1618
1619 - root 3.02/06 fixes:
1620 + the memory leak when reading MRawEvtData
1621 + loosing more time than necessary to update the progress bar
1622
1623 - MWriteAsciiFile is now capable of writing more than one container
1624 in a line. For example: To be able to write Monte Carlo and
1625 Hillas values (energy and alpha) in one line.
1626
1627
1628
1629 *** Version 0.5 (2001/11/06)
1630
1631 - Added new GUI functionality (Analysis)
1632
1633 - Added a camera display to be able to display events in the camera
1634 together with the calculated hillas ellipse
1635
1636 - Added a 'Clone'-Task (MClone) which can clone a parameter container
1637 object at any state of the analysis, so that the output are several
1638 states
1639
1640 - Fixed a bug in the collection area error calculation
1641 (Thanks to Ciro and Abelardo)
1642
1643 - Fixed a bug which causes merpp to crash in some environments
1644
1645 - Implemented auto enabling scheme for Branches to speed up reading
1646 a lot (see MReadTree and MTask)
1647
1648 - Fixed a bug in the Histogram classes which caused histograms to
1649 be written to a file by MWriteRootFile without request
1650
1651 - changed the object I/O from the old stylish root I/O to the new
1652 'auto evolution scheme' This was done only for classes which are not
1653 yet used in Monte Carlo files, so that these files are still readable.
1654
1655 - Added support for a progress bar in MEvtLoop and MReadTree
1656 (see the Analysis Window in Mars for an example)
1657
1658 - Fixed a bug in the package creation which disturbed the conversion
1659 between a mars version unpacked from a tar file and the repository.
1660
1661 - Changed the code to writer merpped (converted into root format)
1662 raw files, to get faster (around 10%)
1663
1664
1665
1666 *** Version 0.4 (2001/09/20)
1667
1668 - This release is made to compile on a root version >= 3.00
1669
1670 - Fixed a bug which causes MReadTree to read the first file only
1671
1672 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
1673
1674 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
1675
1676 - Added a task to write several container to a root file (MWriteRootFile)
1677
1678 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
1679
1680 - Added calculation of the collection area (MMcCollectionAreaCalc)
1681
1682 - fixed some bugs in the Hillas calculation
1683
1684 - added filters to be able to control the task execution dependent on
1685 a parameter (for example: the number of level 1 triggers in a MC-file)
1686
1687
1688
1689 *** Version 0.3 (2001/04/23)
1690
1691 - Many demo macros added
1692
1693 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
1694
1695 - Hillas Calculation added
1696
1697 - Standard image cleaning available
1698
1699 - MReadTree is now able to handle more than one file
1700 (Remark: of the same structure)
1701
1702 - Now we are able to display events in a first version of the
1703 Camera event display. To do this we must run the macro
1704 "macros/readCT1.C" to read data from CT1.
1705
1706
1707
1708 *** Version 0.2 (2001/01/24)
1709
1710 - First Implementation of a Gui to read the raw data. Start the
1711 gui with the command mars.
1712
1713
1714
1715 *** Version 0.1 (2000/12/20)
1716
1717 - First official release 0.1
1718
1719 - Changes:
1720
1721 + changed calling style of MRawPixelIterator from do...while to
1722 while-loop
Note: See TracBrowser for help on using the repository browser.