1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: Website to plot values from the database has been added.
6
7 - general: The changes to the interpretation of phrases lead to
8 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
9
10 - callisto: Redone the signal extraction this includes:
11 + Unified the algorithms to extract the pedestal for all pedestal
12 extractions done
13 + Unification of hi- and lo-gain into one array
14 + Unification of hi- and lo-gain extraction for Spline and
15 Digital Filter (means now exactly the same algorithm is used,
16 not a copy-and-pasted one)
17 + Store pedestal subtracted data in a common place
18 + Improved extraction algorithms. If the algorithms search a
19 maximum but don't find one they don't return the maximum anymore
20 + Improved the extraction such that a information for signal
21 and time which is consistent is returned
22 + replaced the numerical spline with a (not slower) analytical
23 solution
24 + Lowered the saturation limit from 250 to 245 to make sure that
25 we are far away in all pixels from problems with the clock-noise
26 + Changed the lo-gain start shift from 2.5 to 6.0 which gives
27 clearly smoother results (to be investigated further)
28
29
30
31 *** Version 0.10.3 (2006/10/23)
32
33 - database: Implemented ObservationMode flag in websites.
34
35 - database: For sequences there is now also the stoptime available on the
36 websites.
37
38 - database: Removed ManuallyChanged flag from sequence-info websites,
39 as it is not needed anymore with the new sequence building algorithm.
40
41 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
42 Class for calculation of confidence intervals (upper limits).
43 Use model 3 or 4 for upper limit calculation for MAGIC observations.
44 Please read the class instruction of TRolke for more information.
45
46 - general: The programs now return 0xfe if the requested resource file
47 doesn't exist.
48
49 - general: Errors comming from root itself are now not output to
50 stderr anymore but to our default (colored) log-stream.
51
52 - general: Changed the interface to TFormula such that now everything
53 is parsed by TFormula, which should allow to use phrases even
54 without paranthesis correctly parsed.
55
56 - callisto: replaced the AdHoc number of effective integration slices
57 in the digital filter by an average of the correct number, averaged
58 over all possible set of weights. This also gives correct numbers
59 for the lo-gains which were totally wrong before.
60
61 - callisto: drastically reduced memory consumption by not storing
62 all intermediate calibration results in memory anymore (we might
63 write them into a file in the future)
64
65 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
66 debug plot displayed as a standard plot) use the context menu
67 somewhere between the two upper plots, click on "DrawNicePlot"
68 and enjoy the result. (It is the same context menu which contains
69 the "DrawAll" option)
70 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
71
72
73
74 *** Version 0.10.2 (2006/10/15)
75
76 - general: changed the building of the sequence files such, that
77 the source-/project name in case of wobble-sources is not the
78 source/project of the first data run anymore but the new generalized
79 wobble source/project
80
81 - general: Added some functions to MAstro to calculate sun and
82 moon properties
83
84 - general: Added two new macros (starvisday.C and starvisyear.C)
85 which allow to plot the visibility of several stars in one day
86 or of one star along one year
87
88
89
90 *** Version 0.10.1 (2006/10/11)
91
92 - general: HTML logging output was distorted... fixed.
93
94 - general: Changed the writing of the sequencefiles such that only
95 as many pedestal files as giving at least 1000 pedestal events which
96 are nearby the first calibration run are used as pedestal runs
97
98 - sponde: In the calculation of the collection area(s) and the
99 distribution for MOnte Carlo and estimated energy the error
100 calculation was wrong because root didn't take the errors
101 properly into account... fixed.
102
103
104
105 *** Version 0.10 (2006/10/10)
106
107 - general: all executables now check consistency of the root version
108 installed with the root version used for compilation. The return
109 code in this case is 255.
110
111 - general: The algorithm to build seqeunces has been redesigned
112 completly. It is now more flexible in terms of a resource file
113 resources/sequences.rc which can be used to partly overwrite
114 the default algorithm and defined the important part of the
115 algorithm. It also takes correctly into account several ways
116 of taking wobble-data. Currently the new algorithm doesn't take
117 the number of pedestal events anymore into account (so a sequence
118 could have much less than 1000 pedestal events and data runs are
119 no-more used instead)
120
121 - general: a lot of small changes to make the code compatible with
122 root 5.12/00 and gcc 4.1
123
124 - general: Fixed some warnings thrown if more warnings are switched
125 on in the compiler
126
127 - general: Added a function to MMath which returns the Median of
128 the distribution abs(y[i]-median) but at 68:32 division instead
129 of 50:50, which is somehow the median counterpart of the rms.
130
131 - general: MAstroCatalog allows now to read calatog files (as bsc5)
132 even if they are compressed with gzip (recommended compression
133 is with "-1")
134
135 - showplot:
136 + batch mode creation of image files now works with root 5.12/00
137 + added support for writing bmp (though it never produces
138 bmp which can be read by programs like xv or gimp)
139 + added support for xml
140 + added new option to start the display with a different size, by
141 --display-width=nnn or --display-height=nnn
142 + added options to define the canvas size when the display is started
143 --canvas-width=nnn or --canvas-height=nnn
144 the option can also be used for batch-mode conversion
145 + added an option which automatically fits the display size to the
146 desktop-size: --auto-size
147
148 - merpp: didn't recognize files with the extension .raw.gz - fixed.
149
150 - merpp: allow the reports to have 1000ms due to a bug in the camera
151 program.
152
153 - callisto: New swapped pixels have been found and corrected. For
154 details see MRawRunHeader::FixAssignment()
155
156 - callisto: Callisto now raises an error if one of the input files could
157 not be opened.
158
159 - callisto: In some rare cases it could happen that in the hi-gain
160 extraction of the digital filter the extractor returned nonsense
161 results due a wrong initializion of a variable
162
163 - callisto: The lo-gains have been marked as valid in some cases
164 when they got not extracted at all (deltsumlo=deltatimelo=0) because
165 the allowed extraction range (fLoGainLast-fLoGainFirst) was
166 smaller than the number of slices (fLoGainWindowSize) needed
167 by the lo-gain extractor
168
169 - callisto: Updated absolute calibration constants (muon calibration)
170
171 - callisto: fixed a bug which caused the hi-gain saturation not
172 to be handled properly
173
174 - callisto: fixed a bug which gave weird results if hi- _and_
175 lo-gain could not be extracted properly
176
177 - callisto: improves handling of extracted signal if lo- and/or
178 hi-gain could not be extracted properly. If no appropriate
179 calibration of either the signal or the arrival time is possible
180 the pixel is now markes as unsuitable instead of estimated.
181
182 - callisto: Fixed a problem in the spline extraction which gave
183 weird results if the signal was extracted from the first (and
184 highest) slice
185
186 - callisto: Fixed a bug regarding the use of the QE which doesn't
187 effect the result because the default is used anyhow.
188 (The bug was there since 14/07/2005)
189
190 - callisto: Changed the default for fgLoGainStartShift
191
192 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
193 factors to be always 10 for all pixels as soon as the first
194 calibration update has happend.
195
196 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
197 was off by more than one slice (which gives wrong values for
198 pixels which have saturated the hi-gain) This was a problem
199 mainly for timing studies, not so much for the automatic standard
200 analysis. Also the values for the Spline have been changed slightly:
201 + Digital Filter from 1.70 to 0.95
202 + Spline from 1.39 to 1.30
203 The numbers were sorted out by an extensive test in the
204 test-database.
205
206 - callisto: Removed the tab showing the average calibrated arrival
207 time. It never gave useful information.
208
209 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
210 lo-gain pulse for data pulses if hi- and lo-gain have saturated
211 and both were extracted because the hi-gain was above the
212 LoGainSwitch.
213
214 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
215 lo-gain pulse position (after application of LoGainOffset, which
216 means in the ideal case it is 0) for data pulses if hi- and lo-gain
217 have saturated and both were extracted because the hi-gain was above
218 the LoGainSwitch.
219
220 - callisto: After extensive tests a new threshold level for determination
221 of the pulse position has been found at 50phe. This is due to the
222 fact that for lower pulses the arrival time changes its average
223 behaviour dramatically. It tends to the average of the extraction
224 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
225
226 - callisto: Added two more plots to the calibration part. The average
227 extracted signal and the average extracted arrival time as
228 extracted by the signal extractor (This can help debugging problems
229 because it doesn't involve a fit)
230
231 - star: changed the fit for the effective on time such that initial
232 values are calculated automatically now instead of using build
233 in values. This makes the fit more indepedant of the underlaying
234 rates. With a test of ~350 sequences in the test database it could
235 be shown that the new fit gives the same result +/-1sek.
236 The highest deviation was +5s the lowest -10s. You can now control
237 the bahaviour with two resource values:
238 MHEffectiveOnTime.FistBin: 3
239 MHEffectiveOnTime.NumEvents: 12000
240 Use FirstBin=1 and NumEvents=120 to fit the effective on time
241 from the resulting gamma candidates
242
243 - star: The Center histogram in MHHillas is now by default displayed
244 with the colz draw-option
245
246 - ganymed: now produces valid error codes if failed
247
248 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
249 with the option "hadronness" instead of "area" or "both" if
250 you want to use both cuts. The hadronness cut includes a fixed
251 cut in hadronness (index 8) and a fixed cut in size (index 9).
252
253 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
254 the M3Long of the anti source to be not properly evaluated
255 (actually is was evaluated as a unique random number) in case
256 of optimization with anti-theta cut switched on. This might have
257 lead to improper, but not necessarily wrong, optimization results.
258
259 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
260 how to use random forest
261
262 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
263 ganymed_onoff.rc. Seems to be unintentional that they were different.
264
265 - sponde: Since the introduction of the possibility to define a
266 normalization energy instead of using the integral the default
267 was not using the integral anymore but a normalization energy of
268 1GeV. It is now the integral again.
269
270 - sponde: Fixed a problem in the weighting which did not allow
271 a MC slope of -1.
272
273
274
275 *** Version 0.9.6 (2006/05/24)
276
277 - general: changed the binning of the azimuthal profile of the camera
278 such that it is aligned with the 60deg boundaries.
279
280 - merpp: better handling of problems with the TH, TD part of the
281 CC-REPORT for files older than 200507190 and 200412210
282 respectively
283
284 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
285
286 - merpp: implementd latest changes in starguider reports (sinc 9th May)
287
288 - callisto: if an arrival time is extracted outside the fadc range is
289 was set to the boundary before. Now a random number is assigned
290 instead to avoid unfortunate coincidences of arrival times just
291 by this arbitrary value.
292
293 - callisto: added a new option to callisto.rc which allows
294 to set the maximum arrival time difference allowed for the
295 badpixel algorithm to determin whether a pixels belongs to a shower:
296 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
297
298 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
299 to 0.9 as suggested by Stefan due to a recent study on the fraction
300 of pixels surviving the image cleaning
301
302 - callisto: switched off error in case of "pulse is too much to the left"
303
304 - callisto: The extraction window is not adapted anymore. This means that
305 the pulse is extracted from the full range. The draw-back is that the
306 background (pedestal) will become slightly higher. Switching on/off
307 the PulsePosCheck in the callisto.rc only effects filling the
308 histograms.
309 WARNING: If the pulse is too much to the left data is calibrated!
310 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
311 in the database to make sure that your data is valid!
312
313 - star: Show also the number of stars correlated correctly by the
314 starguider
315
316 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
317 than one off-source region in wobble-mode. To use it add the following to
318 your ganymed_wobble.rc:
319 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
320 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
321 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
322 + Cut1.ThetaCut: None
323 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
324
325 - ganymed: in the case the latest report is older than a default (currently
326 one minute) and the current report will be skip the starguider
327 correction and calibration will be reset. The maximum age can be
328 setup from ganymed.rc by (minutes):
329 MPointingDevCalc.MaxAge: 1.5
330
331 - ganymed: A first implementation showing all size-bins for the theta-sq
332 resp. alpha-plots in a single tab automatically
333
334
335
336 *** Version 0.9.5.1 (2006/05/05)
337
338 - general: Added a new option "zdiff" to the Makefile which runs
339 "cvs diff" as "make diff" would do, but with compression
340
341 - general: accelerated MTFillMatrix (used for eample in all training
342 and optimization macros) by skipping some obsolete calles in the
343 eventloop the first and second loop could be accelerated by ~20%
344
345 - general: Added a missing feature in the MFilterList class which
346 prevented MFEnergySlope from working correctly in trainenergy.C
347
348 - general: Accelerated the random forest training and usage a bit
349
350 - merpp: Adapted to new raw data file format version 6
351
352 - merpp: fixed a problem with reading the starguider reports
353 after 6.3.2006
354
355 - callisto: At some times six pixels had to be exchanged manually in the
356 data. If the pixels to be swaped are both not found, an error was raised
357 and calibration was stopped. Now it is assumed they are intentially not
358 mapped and the Error has been changed to a Warning.
359
360 - star: Added new image cleaning based on the arrival time of the shower.
361 The new cleaning can be accessed using the parameter "Time" instead of
362 the the old one (like "Absolute) in the star.rc-file.
363 Recommended parameters:
364 + MImgCleanStd.CleanLevel1: 8.2
365 + MImgCleanStd.CleanLevel2: 5
366 + MImgCleanStd.CleanRings: 2
367 + MImgCleanStd.KeepSinglePixels: No
368
369 - star: Simplified the calculation of the effective on time. By letting
370 the fit start in the third bin the result should become more stable.
371 The fit quality is now ignored for the theta-plot which is not used
372 in the analysis later. Still better pre-cut which, for example,
373 remove events triggered by car-light (rate changing on a short
374 time-scale) are missing.
375
376 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
377 for optimization (kWeakSource) which is suggested by the Berlin
378 people for weak sources.
379
380 - macros: plotdb.C:
381 + if no dataset and no time-interval is given only sequences with
382 an effective on-time above five minutes are plotted anymore
383 + added a new tab "RelTime" displaying the relative on-time
384 (effective on-time divided by the observation time)
385
386 - macros: optim*.C: by skipping some obsolete calles in the eventloop
387 the optimization became a lot faster
388
389 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
390 To display them just delete the pads displayed on top.
391
392 - ganymed: fixed a bug which could cause strange behaviour in wobble
393 mode if no starguider information was available due to an incorrect
394 initialization of the starguider calibration
395
396 - ganymed: The scale region in the False Source Plot (MHDisp) can now
397 be changed from within the plot. It can also be setup from the
398 resource file using:
399 + MHDisp.fScaleMin: 0.325
400 + MHDisp.fScaleMax: 0.475
401
402 - ganymed, showplot: Fixed a problem with the fit to the off-data
403 (HistOff) which could cause a time lag or an inifinite loop.
404 The bug did not effect the results at all.
405
406 - sponde: Added a new tab showing the effective collection area after
407 trigger (including the software trigger)
408
409 - sponde: MMcSpectrumWeight has a new option which allows to define
410 the scaling factor not by the integral of the events but at
411 a defined energy:
412 e.g. MMcSpectrumWeight.NormEnergy: 200
413
414 - MTFillMatrix, sponde: by skipping some obsolete calles in the
415 eventloops the loop could be accelerated by ~20%
416
417
418
419 *** Version 0.9.5 (2006/03/13)
420
421 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
422 and added the standard Disp-parametrization
423
424 - macros: added a new macro datacenter/macros/plotstat.C allowing
425 to plot statistics about the data processing
426
427 - macros: added a new macro to plot the muon correction coefficients
428 versus period (macros/plot/mucal.C)
429
430 - showplot: path inflation for ganymed files was broken
431
432 - callisto: Fixed an important bug. When the number of saturating pixels
433 were calculated the bad pixel information already available from the
434 calibration was ignored. This yields wrong values in case pixels
435 are broken and saturate all the time or randomly.
436
437 - callisto: Updated Muon calibration constants. Spline data now also uses
438 different values for different periods
439
440 - star: The time-evolution shown in the effective on-time plot now displays
441 the axis range (if there are no holes it should be similar to the
442 effective on-time)
443
444 - star: Added two new image parameters:
445 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
446 the three pixels next to the center of gravity and the size
447 + MNewImagePar.fConcCore: The ratio of the signals of all
448 pixels inside or touching the ellipse and the size
449
450 - ganymed: now stops in requested source isn't found in catalog file
451
452 - ganymed: Many improvements to the phi-plot in wobble mode:
453 + with a template the ideal background is displayed
454 + a possible camera inhomogeneity is taken into account
455 + the anti theta cut is better supported
456 + the phi cut is automatically calculated from the theta cut
457 See the examples in ganymed_wobble.rc for more details.
458
459 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
460 times the bin-width instead of the absolute energy
461
462 - ganymed: New cuts for on/off and wobble mode
463
464 - ganymed: The smearing of the False Source plot has been increased
465 to 0.06
466
467 - ganymed: The starguider calibration can now be changed from the
468 resource file.
469 See the examples in ganymed*.rc for more details.
470
471 - ganymed: added a new option for on-/off-observations
472 MJCut.RandomSourcePosition
473 If switched on the distribution of observation time of the source
474 position in the camera is calculated from the on-data and randomly
475 applied with this distrbution to the off-data.
476
477 - ganymed: by skipping some obsolete calles in the eventloop the
478 first and second loop could be accelerated by ~20%
479
480 - ganymed: The default in ganymed_onoff.rc is now to determin the source
481 position in the off-data randomly according to its distribution in the
482 on-data.
483
484
485
486 *** Version 0.9.4.3 (2006/02/13)
487
488 - general: Fixed a bug in most of the programs which prevented the
489 compile date in the startup message to be displayed
490
491 - general: Simplified program calls. The following abbreviations
492 are now possible:
493 showlog callisto 55599
494 showplot signal 55599
495 star 55599
496 callisto 55999
497 ganymed 2
498 In this cases the corrsponding root-, log-, sequence- or dataset-
499 filename is automatically compiled using the default datacenter
500 paths ("/magic/*")
501
502 - general: Fixed a long outstanding bug which made axis tick marks
503 disappear if MDataFormula was used (eg. abs(x))
504
505 - general: Updated MMath with new functions to calculate the results of
506 a exponential, logarithmic and powerlaw fits analytically.
507
508 - general: Updated some macros with comments:
509 + macros/optim/optimdisp.C
510 + macros/optim/optimenergy.C
511 + macros/optim/optimwobble.C:
512
513 - general: MTFillMatrix (the class to fill one or two MHMatrix from
514 files) now allows adding a pre-cut like in the optimization. E.g. this
515 is useful to perform g/h-separation cuts before training the random
516 forest.
517
518 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
519 correctly assigned in the raw data assignement table. A fix to correct
520 the assignment tabel have been implemented.
521
522 - general: MAstroCatalog now allows rotating of the sky-grid and stars
523 by 90, 180 and 270 deg.
524
525 - general: the macro plotdb.C now allows to highlight sequences belonging
526 to a datset. For more details see the descritions in the macro.
527
528 - StatusDisplay: Fixed the algorithm to calculate the size ratio
529 of the display, it gave wrong results espacially for big sizes.
530 Now the embedded canvas should always have a ratio width/height=3/2.
531 The "Size" options have been updated with values fitting the 3/2
532 size ratio.
533
534 - RanForest:
535 + Updated the random forest classes to support also the
536 regression method implemented by Thomas H.
537 + added new tutorial macro how to train the random forest
538 for energy estimation (macros/optim/rfenergyest.C)
539 + new classes to train the random forest (still in development)
540 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
541 + new tutorial macros for random forest training in macros/train
542 trainenergy.C, traindisp.C, trainseparation.C
543
544 - mars: now allows to setup a cut in the resource file mars.rc to choose
545 the events to be displayed, eg:
546 Cut.Condition: {0} && {1}
547 Cut.0: MHillas.fSize>100
548 Cut.1: MHillas.fSize<900
549
550 - merpp: Made aware of the new .rep format 200510250. This includes
551 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
552 the discriminator thresholds (MCameraTD) and the disciminator
553 delays (MCameraTD). All of them come with the CC report and are therefor
554 written to the CC tree.
555
556 - callisto: fixed a bug in the calculation of the arrival times in
557 the Digital Filter. They were all shifted by the same amount
558 fHiGainFirst. This caused an offset in the order of the position of
559 the left border of the extraction window in the times calculated
560 from high-gain and from low-gain. The bug effected only the absolute
561 arrival times. The bug was there since 30.1.2005.
562
563 - callisto: Changed the ExtractionWindow for the pulse position check
564 such that the camera inhomogeneity becomes as less as possible and
565 comparable to the pulso position check switched off. More details
566 on the study will be given at our result web-page.
567
568 - ganymed: ganymed.rc, ganymed_onoff.rc:
569 changed to new cuts trained with 1ES1218 and Crab-data
570 for maximum sigma*log10(excess)
571
572 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
573 a new option was implemented to estimate Disp (CalcDisp)
574
575 - ganymed: Implemented two new options which allow
576 to overwrite the default path to search for the sequence files
577 --ins=/magic/sequences
578 and where to search for the image data
579 --ind=/magic/data/star
580
581 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
582 dx/dy from the resource file by
583 MSrcPosCorrect.Dx
584 MSrcPosCorrect.Dy
585
586 - ganymed: fixed reading the source catalog. Only as many chars
587 as the requested source name had were compared (If a source
588 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
589 were requested it could happen that the coordinates of
590 "1ES1218" were read) The source coordinates are now printed
591 in addition to its name to the logging output.
592
593 - ganymed: changed the background fit in the case of a ThetaSq function
594 from a polynomial to a exponential, this should give a big improvement
595 for on-only analysis'
596
597 - ganymed/sponde: Calculation of the error of single size-/energy-
598 bins now uses Li/Ma (5) instead of LiMa (17)
599
600 - sponde: Added a plot E^2*dN/dE
601
602 - sponde: The energy estimator plot should now show values like
603 they are commonly used.
604
605 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
606 (a powerlaw with cutoff didn't work before)
607
608
609
610 *** Version 0.9.4.2 (2005/10/01)
611
612 - general: added new tutorial macro macros/tutorials/threshold.C:
613 how to calculate the threshold
614
615 - general: added a new game. Start it from the interpreter with
616 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
617 and MagicReversi)
618
619 - general: neighbor pixels in MGeoms are now sorted clockwise
620
621 - merpp: made aware of new format 20050829-0
622
623 - callisto: New scale factors from muon analysis, stored in new
624 resource file resources/calibration.rc
625
626 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
627 the eventloop if something went wrong. This is necessary for the
628 automatic processing
629
630 - callisto: Implemented a new treatment for the time information
631 developed by S.Ruegamer, this should give much better response than
632 the old very primitive algorithm. This is especially important
633 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
634 treatment was buggy! As neighbor pixels to interpolate the
635 arrival times always the pixels 0 to 5 were taken)
636
637 - callisto: In addition to the new treatment of arrival times the
638 decision of the treatment whether a pixel contains shower
639 information or not is used to improve the signal interpolation
640 further. Previously interpolated pixels showed a non-zero signal
641 do the peak searching signal extractors. Having a signal pixel
642 beside raised the signal above the cleaning level. Thus the
643 pixel survived cleaning to often but with a too low mean signal.
644 By replacing empty pixels with a gaus (mean and rms from the
645 corresponding Area entries in MPedPhotCam) this effect can
646 be supressed.
647
648 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
649 got lost when the events were stored by the calibration... fixed.
650 (This was no problem for normal image cleaning because the pixel
651 content was artificially set to 0 not surviving standard cleaning
652 algorithm)
653
654 - callisto: Fixed a bug which caused the random and peak-search pedestal
655 extracted with an extractor to be exchanged for the first (roughly)
656 500 events (*Extractor and *ExtractorRndm).
657 (They were simply exchanged in callisto.cc) This bug might have been
658 introduced in Mars 0.9.4 when the order of calculation of the two
659 types of pedestal in callisto got exchanged. The bug only effects
660 the first seconds of data of each sequence.
661
662 - star: Taking the arrival time of Muons into account the calculation
663 of the parameters could be made independant of the noise
664 (pedestal rms). The dependance was due to the bias of the peak search
665 extractor. Now only a ZA dependamcy is left which is not yet fully
666 understood.
667
668 - ganymed: The sequences were still not sorted correctly in any case,
669 because they were sorted by the full qualified path name. Now they
670 are sorted by their sequence number.
671
672 - ganymed: new values for the spark-event-cut
673
674 - sponde: required missing MEnergyEst from ganymed.root... fixed.
675
676
677
678 *** Version 0.9.4.1 (2005/08/18)
679
680 - callisto: fixed some problems with the calibration in case of
681 inteleaved events. Therefor the final and some intermediate
682 fits are skipped which would take place on partly filled #
683 histograms and gave wrong results or failed completely.
684
685 - callisto: If the intermediate finalization of the histograms
686 calculating the mean charge of the calibration signal fails
687 it is counted now and printed in PostProcess of MCalibCalcFromPast.
688
689 - ganymed: Fixed some bugs which caused problems in On-only mode.
690 Still the false source plot doesn't give reasonable results.
691
692
693
694 *** Version 0.9.4 (2005/08/05)
695
696 - general: Fixed the ZA binning. It did not correctly fit the
697 MC binning
698
699 - general: Added a class to correct for the missfocussing in
700 April (MSrcPosCorrect)
701
702 - general: Random Forest energy estimator should now work properly
703
704 - general: MHCamera now displays the profiles in deg instead of mm
705
706 - general: MH::SetPalette offers a lot of new palettes
707
708 - general: MHillas - the case of CorrXY==0 is now handled properly
709
710 - general: implemented the possibility to change the line and
711 marker style of a sky-grid drawn by MAstroCatalog
712
713 - general: Runs in sequences and datasets are now automatically
714 ordered (it is assumed that the order of their filenames correctly
715 represents the order of observations) to ensure correct reading
716 of the subsystem data
717
718 - general: Runs cannot be added to a sequence twice anymore. Also
719 Sequences cannot be added twice anymore to a dataset.
720
721 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
722 It gave wrong results by 1./2pi
723
724 - showplot: got a new option to start a root interpreter, too
725
726 - mars: now displays a rough estimate of Disp and the third moment
727
728 - mars: now displays the event time MTime if available
729
730 - mars: show muon parameters graphically
731
732 - mars: now the file to open can be given as commandline
733 argument
734
735 - merpp: Added support for new arehucas version >= 200507190
736 implementing values for three temperature sensors in the
737 counting house (MCameraAUX) and the name of the HV settings file
738 (MCameraHV).
739
740 - merrp: Also fixed some problems with wrong versions numbers stated
741 by arehucas and implemented some fixed for old versions (<200407070)
742
743 - callisto: MCalibrationHiLoCam can now be printed from its context
744 menu, eg in the TBrowser
745
746 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
747 - 1.39 (MExtractTimeAndChargeSpline)
748 - 1.40 (MExtractTimeAndChargeDigitalFilter)
749 This is important mainly for timing studies.
750
751 - callisto: Changed limits in MHCalibrationChargeCalc from
752 - -100.125 to -98 (fgChargeHiGainFirst)
753 - 1899.875 to 1902. (fgChargeHiGainLast)
754 - -100.25 to -99 (fgChargeLoGainFirst)
755 - 899.75 to 901. (fgChargeLoGainLast)
756 Introduced new limits:
757 - fgNumLoGainBlackoutLimit: 0.05
758 - fgLoGainBlackoutLimit: 3.5
759 - fgLoGainPickupLimit: 3.5
760
761 - callisto: The handling of automatic weights for the digital filter
762 has been improved. There are now new calibration weights special
763 for Monte Carlo calibrations.
764
765 - callisto: Updated Muon scale with latest results (1% difference
766 for most data, 5% for Mar/Apr'05)
767
768 - callisto: use a new criterium to exclude bad pixels: If the high-gain
769 was saturated and the blackout-events in the low-gain exceed the
770 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
771 This excludes those pixels which have a saturating high-gain
772 channel, but the low-gain switch does not switch often enough
773 to make the distribution reliable.
774
775 - callisto: fix a bug counting the number of saturated events. Up to now,
776 the number of saturated slices was counted (which is one for a not too
777 high number), but for some (pathological) pixels, many more slices
778 saturated and produced wrong limits.
779
780 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
781 + MCalibrationRelTimeCam.CheckFitResults: Yes
782 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
783 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
784 + MCalibrationRelTimeCam.CheckOscillations: Yes
785
786 - callisto: introduce max. number of events for intercalibration,
787 the rest gets skipped. Default: 4096
788 The calibration causes too many un-reliable pixels if more
789 than about 5000 events are treated (@500 Hz) because of the
790 mode hopping of the VCSels. However, in the past, some
791 calibration runs have been taken (erroneously) with more
792 than 5000 events, especially the intensity scans where
793 a good precision is needed.
794
795 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
796 photo-electrons for the spline extractor by 1-2% (correctly).
797
798 - callisto: The intercalibration is now done using a full f-factor
799 method instead of a simple update. This makes things slower but
800 more reliable in terms of gain-fluctuations and sudden VCSEL gain
801 changes.
802
803 - callisto: MPedestalY3 now uses the same extraction range as the data
804 as calculated by MPedestalY2
805
806 - callisto: A check of the fraction of allowed unsuitable (10%) and
807 unreliable (30%) pixels has been addded when the conversion is
808 calculated from interleaved events
809
810 - star: fixed a bug which caused MEffectiveOnTime containers not to
811 be written. In the worst case they were skipped almost all, in the
812 best case they were all ok. It depends on how often the new value
813 was assigned just with an event which was skipped later by another
814 task
815
816 - star: new histograms MHPointing and MHRate
817
818 - star: New tab (Currents) displaying the time evolution of the mean
819 DC currents
820
821 - star: New tab (MeanRms) displaying the time volution of the mean
822 Pedestal Rms
823
824 - star: Output now contains MReportStarguider
825
826 - star: Improved muon analysis. Due to the absense of a constant
827 for the gaus fit for arc width and the fact that the arcwidth
828 plot was a histogram instead of a profile the resulting psf
829 became pedestal rms dependant
830
831 - ganymed: added new plot (MHPhi) for wobble mode as described in
832 http://www.astro.uni-wuerzburg.de/results/ringmethod/
833
834 - ganymed: corrects now (correctly?) for the misspointing in
835 May/April 05
836
837 - ganymed: Two new default templates for ganymed.rc are avilable:
838 ganymed_onoff.rc and ganymed_wobble.rc
839
840 - ganymed: The first version of MFMagicCuts has been released
841
842 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
843
844 - ganymed, sponde: There are two new options to determin the number
845 of bins for the signal region (NumBinsSignal) and the number of
846 total bins (NumBinsTotal) in the MHThetaSq histogram
847
848 - ganymed: optimized palettes for MHDisp
849
850 - ganymed: Fixed an important bug when using ThetaSq as fit function:
851 The result for the sigma of the gauss(sqrt(x)) fit was a factor
852 sqrt(2) to large
853
854 - ganymed: The false source plot (MHDisp) is now based on Disp
855 and a background model determined in the first loop is
856 subtracted
857
858 - ganymed: MFMagicCuts are now available in the cvs. The correct
859 solution for the disp ambiguity problem is now calculated using
860 the third moment. The third moment cut therefor is skipped.
861
862 - ganymed: Output now contains "Disp [MParameterD]" which sign is
863 already determined by the third moment along the major axis and
864 so its actual sign is aligned along the major axis of the shower.
865
866 - ganymed: If starguider data is available it is taken into account
867 when calculating the source position. This is especially important
868 for wobble data at high zenith angles and culmination data.
869
870 - ganymed: If available the starguider data is taken into account as
871 good as it is possible without a starguider calibration. To switch
872 it off add
873 MPointingDevCalc.MaxAbsDev: -1
874 to your ganymed.rc
875
876 - sponde: the zenith angle distribution is now weighted instead of
877 choosen by default. This gurantees higher statistics in the highest
878 and lowest energy bins. To switch this behaviour off use...
879
880 - sponde: now automatically displays the energy threshold
881
882
883
884 *** Version 0.9.3 (2005/06/03)
885
886 - general: MMcEvt now derived from MMcEvtBasic which should
887 have no influence on compatibility with older camera files
888
889 - general: Implemented a new option to MReadReports which allows
890 to force reading of the first event of some trees (eg. Drive-tree)
891 before any other tree.
892
893 - general: Made a fix to MPointingPosCalc which assumes that the
894 run-type is real-data if Process is called before ReInit, such
895 that also the very first Drive-events in a run are treated
896 correctly.
897
898 - shoplot now displays the filename in the title bar of the window
899
900 - merpp: new options: --auto-time-start --auto-time-stop which
901 allow to cut updating with slow-control at the start- or
902 (previousle --auto-time only allowed: and) stop-time of
903 the run stored in the runheader.
904
905 - callisto: changed default of fgFallTimeHiGain in
906 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
907 already set as default in callisto_Dec04Jan05.rc
908
909 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
910 now changes the filename for new weights automatically for
911 cosmics, MC and for different calibration colors.
912
913 - callisto: a problem with the order of some code cause the
914 name of the weights file in MPedestalY2 to be ignored.
915 Wrongly the calibration_UV weights were used instead
916 of the cosmics weights set in callisto.rc.
917
918 - callisto: should allow ct1 pulser data when the color is
919 explicitly set also for pretty new runs
920
921 - callisto: a new option (MCalibrateData.ScaleFactor) allows
922 to introduce an additional scale factor (should be around 1)
923 to adapt for slight deviations in different extractors from
924 the MC calibration. For MC calibrations the scale factor
925 is fixed to 1
926
927 - callisto: MFCosmics should handle very high signals a bit
928 more accurate now
929
930 - callisto: when calculating the mean pedestal rms for different
931 pixel sizes or sectors also kUnsuitableEvt is now taken into
932 account - not only kUnsuitableRun
933
934 - callisto: '-raw' option is now the default
935
936 - callisto: A dead pixel check has been implemented in MJPedestalC2.
937 This has the advantage that mean values in the calibration (eg
938 arrival times) are calculated more accuratly.
939
940 - callisto: In the resource file callisto_Dec04Jan05.rc
941 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
942
943 - callisto: new Hi-/Lo-Gain intercalibration constants
944 hilocalib_sp1.root and hilocalib_sp1_mc.root
945
946 - callisto: changed default for MJPedestalY2.MaxEvents
947 from 2000 to 5000 like in callisto_Dec04Jan05.txt
948
949 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
950 has changed from 9.0 to 6.0. This is necessary to exclude two very
951 ringing pixels in September which - when kept - destroy the image
952 cleaning around them (Markus G.)
953
954 - callisto: (!) The Muon analysis of all data taken so far has
955 suggested that different extractors give slightly different
956 absolute results after calibration, due to there different
957 handling of the calibration- and cosmics pulse shape. Although
958 the over all calibration seems to be a bit to pesimistic (or
959 the MC seems to be a little bit - 3-5% - too much attenuated).
960 There for correction factors have been introduced which correct
961 the calibration constants by
962 0.956937799 for Digital Filter (callisto.rc)
963 and
964 0.904159132 for Spline (callisto_Dec04Jan05.rc)
965 calibration. The main advantage is, that both data types can
966 be easily analysed together and compared to the same MC sample.
967 The factors are choosen such, that the reference is now a
968 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
969
970 - star: fixed a bug which caused the first bin of the histograms
971 vs time to disapear in PostProcess. This gave wrong results
972 on the screen. The output and all following programs not
973 directly accessing the histograms haven't been affected
974
975 - star, ganymed: Made sure that always the first Drive-tree event
976 is read and Processed before the first data event was read.
977
978 - ganymed: implemented the possibility to replace the standard
979 false source plot with a different one. For example: If
980 you want to use a Disp based FS plot use the resource:
981 NameHistFS: MHDisp
982 For details about the requirements of these plots look
983 at the corresponding classes
984
985 - MJOptimize: For On/Off and Wobble optimization MJOptimize
986 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
987 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
988 case MAlphaFitter is setup correctly. For On-Only optimization
989 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
990 RunOn() instead of Run(). For energy estimation MJOptimize
991 has been replaced by MJOptimizeEnergy
992
993 - sponde: The input MC spectrum can now be weighted to fake a
994 different spectrum. This is done via MMcSpectrumWeight. For
995 more details see the class description and sponde.rc
996
997 - sponde: The paremeter comparsion plots are not scaled by
998 their entries anymore. Instead the MC plot is scaled by using
999 the result spectrum of the analysis. If the input MC spectrum
1000 and the result spectrum has different slopes the absolut
1001 normalization is normally wrong.
1002
1003
1004
1005 *** Version 0.9.2 (2005/05/20)
1006
1007 - general: Changed the default paths for calibrated data and image
1008 files. (The implemented access to these files doesn't yet exist)
1009
1010 - general: support for MRunIter has been removed from the job classes
1011 (use the setter functions of MSeqeunce instead)
1012
1013 - general: ProcessFile has been renamed to Process in all job classes,
1014 because ProcessFile is missleading
1015
1016 - general: The storage of the palette in MHCamera is now possible
1017
1018 - general: new bits describing unsuitable and unreliable pixels have
1019 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1020 kDeadPedestalRms, kFluctuatingArrivalTimes
1021
1022 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1023 versions newer than V200404070
1024
1025 - general: support for cc file versions newer than V200504130. Added
1026 support for active loads (MCameraActiveLoad) and central pixel
1027 (MCameraCentralPixel)
1028
1029 - general: added new histograms for image parameters versus size
1030 (MHVsSize)
1031
1032 - general: The eventloop now automatically calls PrintStatistics
1033
1034 - Status Display: Improved support for printing:
1035 + A default can now be set in .rootrc (for more details see
1036 MStatusDisplay::PrintPS)
1037 + A print dialog is opened so that printer and command line
1038 can be canged
1039
1040 - showlog: improved such that it handles different verbosity levels
1041 more accurate now. This mean you can suppress output when
1042 using showlog.
1043
1044 - showplot: improved
1045 + The new graphics formats have been implemented
1046 (pdf, svg, png, jpg and xpm)
1047 + Implemented an interface for printing. Because you can change
1048 the printing command from the command line you can use all
1049 the nice postscript tool. To print a booklet for example call:
1050 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1051 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1052 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1053
1054 - callisto: fixed a bug in the recognition of the calibration bit
1055 pattern. Concerns only intensity calibration. (The strength of the
1056 intensity has been updated in some cases)
1057
1058 - callisto: add a filter against PIN Diode events when running over
1059 calibration runs since some of the recent calibration runs have
1060 been taken with Pin Diode.
1061
1062 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1063 39943, 44833 in the calibration (MCalibColorSet)
1064
1065 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1066 been set to 1e-18 in callisto_Dec04_Jan05.rc
1067
1068 - callisto: in callisto_Dec04Jan05.rc: set value for
1069 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1070 statistics for the calculation of the mean pulse time
1071 of the cosmisc
1072
1073 - callisto: the charge limit in the calibration has been raised
1074 from 2.5 to 4.5
1075
1076 - callisto: new setup read from callisto.rc
1077 + MCalibCalcFromPast.fNumEventsDump
1078 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1079 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1080
1081 - callisto: MExtractTimeAndChargeSpline extractor:
1082 + The integration ranges were shifted by 0.2 FADC slices to the right.
1083 + unreliable handling of floating point values caused different
1084 results on different platform or with different compiler options:
1085 The new algorithm is numerically exact and more accurate because
1086 it doesn't calculate the integration position by multiple times
1087 adding the step-size (which results in numerical uncertanties
1088 exspecially if multiplied with large numbers)
1089 + A lot of fixes have been introduced which effects integrating the
1090 spline at the edges of the valid range. In this case any memory
1091 was randomly accessed. This behaviour can be tested replacing
1092 all MArrayF by TArrayF which perform a range check (but of course
1093 they are a lot slower)
1094 ! No result obtained with the Spline before can be trusted! Due to
1095 random memory access it might by completely random!
1096
1097 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1098 + extraction range in the high gain to 4.
1099 + weights file to cosmics_weights46.dat
1100
1101 - callisto:
1102 + introduce the check for fluctuating arrival times.
1103 + set charge limit to from 2.5 to 4.5
1104 + introduce asymmetric exclusion due to "deviating number of phes":
1105 Default: -9.0 +4.5
1106 + make deviating number of phes unsuitable (see David's findings).
1107
1108 - callisto: fixed the display of unsuitable pixels. The old change
1109 to a real profile in MHCamera broke it.
1110
1111 - callisto: The cosmics filter is used in MJCalibration now
1112 independant of the pulser color (formaly it was used only for
1113 CT1-pulser data). The threshold of number of max empty pixels
1114 has been raised from 2% to 5% in MJCalibration. The maximum
1115 fraction of rejected event is 50% otherwise the calibration has
1116 failed. The filter now ignores unsuitable pixels.
1117 Setup the filter from callisto.rc using "ContCosmics"
1118 (see MFCosmics::ReadEnv)
1119
1120 - callisto: changed default for fgOffsetFromLogain back
1121 from -2.8 to -1.8 in digital filter.
1122
1123 - callisto: for the common extractors
1124 + MExtractFixedWindow
1125 * MExtractTimeAndChargeSlidingWindow
1126 * MExtractTimeAndChargeSpline
1127 * MExtractTimeAndChargeDigitalFilter
1128 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1129 and fResolutionPerPheLoGain
1130
1131 - callisto: Updated the hi-/lo-gain intercalibration constants
1132 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1133 hilocalib_df6.root
1134
1135 - callisto: The default lo-gain extraction window for the
1136 MExtractTimeAndChargeSlidingWindow extractor has been increased
1137 from 6 to 8 to take the stretch of the pusle into account
1138
1139 - callisto (!!!): fixed an important bug in the setting of the
1140 incoming pedestal pointer to the signal extractor extracting
1141 pedestals. This bug caused the pedestals not to be subtracted
1142 correctly in the calibration afterwards. The effect was about 10%
1143 too high conversion factors for the digital filter and the spline
1144 and more than 40% for the sliding window.
1145 The bug existed since end of February! (Markus G.)
1146
1147 - star: added muon support to star. A new tab "MHMuonPar" is
1148 displayed. The lower right plot is an estimate of the point spread
1149 function. A reference value is displayed. To get the real PSF
1150 you must compare with MC. The setup for the muon analysis
1151 is done in star.rc. More informations can be found in
1152 MHSingleMuon and MHCalibParCalc
1153
1154 - star: The weather data is now displayed in star
1155
1156 - star: MEventRateCalc handles the calculation of the event rate more
1157 accurate now in case of the start of a new run inside a sequence
1158
1159 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1160 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1161 changed only minimally
1162
1163 - ganymed: (MJCut and MJOptimize) now displayes the number of
1164 excess events versus size. The energy estimation is done in
1165 MJSpectrum (sponde)
1166
1167 - ganymed: got support for using other variables than Alpha, eg. Theta.
1168 Therefor you need a class deriving from MHAlpha which supports
1169 this variable (one is already existing: MHTheta, which is now the
1170 default in ganymed). It is setup through ganymed.rc
1171
1172 - added a full featured spectrum program (sponde) which reads
1173 ganymed output and monte carlos and compiles a spectrum
1174
1175
1176
1177 *** Version 0.9.1 (2005/04/14)
1178
1179 - Fix bug on the arrival time reconstruction when using Digital
1180 Filter (in some marginal cases (10%) times were reconstructed shifted
1181 by 0.2 slices)
1182
1183 - all executables now return 2 where in previous versions -1 has
1184 been returned (gave problems with shell-scripts)
1185
1186 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1187 also done with a intercalibration input file
1188
1189 - a bug in the time fine adjustment of the digital filter has been fixed
1190
1191 - a lot of small fixes to calling TPad::Divide with a margin==0
1192
1193 - MStatusDisplay now shows the memory usage
1194
1195 - added a memory leak statistic after the eventloop
1196
1197 - MHadronness replaced by MParameterD
1198
1199 - MEnergyEst replaced by MParameterD
1200
1201 - wobble mode can now be switched on from the data-set
1202
1203 - switched on bad pixel detection for a pedestal level
1204 which is more than 5 times the variance
1205
1206 - Fixed default paths to be correct for the new data center
1207
1208 - Fixed handling of drive data. The pointing position in now
1209 copied to MPointingPos inside star for real and MC events
1210
1211 - made sure, that the sequences in a dataset are sorted by
1212 their number to ensure the correct synchronization
1213
1214 - added all resource files necessary to handle spline extraction
1215 of signal for the late 2004 and the early 2005 data
1216
1217 - update the reference lines for the december data
1218
1219 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1220 This is important for the Dec. and Jan. data where the calibration
1221 pulse position changes much.
1222
1223 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1224 filter. This corrects only an defective extraction of the MC at
1225 low-gain signals lower than 90 phes.
1226
1227 - fixed some slowdown in calibrating data with interleaved events from
1228 Jan and Dec. As a workaround made the pretty palette the default.
1229 The inverse Deep Blue Sea has a bug which slows down long calibration
1230 runs a lot.
1231
1232 - implemented new values from new starguider report as defined
1233 in TDAS00-07 V7.1 (eg SkyBrighness)
1234
1235 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1236 in starguider report (If you merpp the same reports with this version
1237 you'll get the correct units (arcmin) but a different result
1238 than with old versions (wrong units))
1239
1240 - Now the status display can also write PNG, JPEG and XPM (other file
1241 formats are still unsupported by root)
1242
1243 - added a lot of scripts and macros in directory datacenter used
1244 for automatic processing
1245
1246
1247
1248 *** Version 0.9 (2005/03/23)
1249
1250 - Calibration is now done autmatically into photo-electrons like
1251 decided by the Collaboration Board
1252
1253 - Reference lines in the display can be read from resource file
1254
1255 - Interlaced calibration events can be handled by callisto
1256
1257 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1258 and applied in callisto.
1259
1260 - class MJCalibTest can be called by callisto
1261
1262 - callisto can now run with three data types: rawdata, rootdata, MC
1263
1264 - added two classes mreport/MReportStarguider.cc and
1265 mreport/MReportStarguider.h for implementing starguider-data
1266
1267 - the output of merpp-update now contains starguider information:
1268 MReportStarguider and MTimeStarguider
1269
1270 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1271 values were lower than they should. This was more visible for high
1272 energy (Size) events.
1273
1274 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1275
1276 - added a new loop to callisto to support the correct extraction of
1277 the pedestal and pedestal rms through the signal extractor
1278
1279 - added class to perform fourier tranformation of a hexagonal structure
1280 (MHexagonalFT)
1281
1282 - added class to perform fourier tranformation of a hexagonal structure
1283 in a tasklist (MHexagonalFTCalc) example: hft.C
1284
1285 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1286 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1287 small pixels, example: extendcam.C
1288
1289 - added possibility to write data to memory (TTree) using MWriteRootFile
1290
1291 - added possibility to read a TTree stored only in memory by MReadTree
1292
1293 - new classes to deal with the interleaved calibration events:
1294 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1295
1296 - implemented filters to callisto to skip calibration events
1297
1298 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1299 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1300 the slices by statistics
1301 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1302 signal extractor without randomization
1303 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1304 with the signal extractor with randomization (extraction window is
1305 randomly fixed)
1306 The three kind of pedestal is not yet implemented (for speed reasons) as
1307 long as nobody really needs it:
1308 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1309 extracted with the signal extractor with randomization
1310
1311 - callisto now finds the pulse position in the data automatically
1312
1313 - implemented data reduction in calibrated data by reducing the precision
1314 of the stored floating point values (pedestal, rms and signal) to
1315 roughly 0.5%
1316
1317 - fixed showplot to make file format conversion (eg. converting a
1318 status display stored in a root file into a postscript file) in
1319 batch mode possible:
1320 showplot -b --save-as-ps[=outfile.ps] infile.root
1321
1322 - Allow class names as part of filter rules, eg
1323 (MFSupercuts) && (MHillas.fSize>100)
1324
1325 - fixed a lot of stuff to allow all programs to process MonteCarlo
1326 camera files.
1327
1328 - enhanced possibility to debug reading of resource file
1329
1330 - MDataChain should handle priorities of operator more
1331 accurate now
1332
1333 - completely revised the container in which the signal is stored
1334 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1335 * the new implementation is faster and
1336 * needs less storage space
1337
1338 - FIRST version which can process Monte Carlos through the
1339 whole chain of programs (callisto, star, etc)
1340
1341 - implemented new image parameters for the border length of
1342 the shower image (MNewImagePar2)
1343
1344 - implemented wobble-mode in ganymed
1345
1346 - new class (MJOptimize) taking care of all optimization processes
1347
1348
1349
1350 *** Version 0.8.6 (2004/10/05)
1351
1352 - New combined signal and time extractor
1353 MExtractTimeAndChargeDigitalFilter
1354
1355 - The Report for the trigger section in the CC run summary has been
1356 updated, and now the IPRs (Individual Pixel Rates) are available.
1357
1358 - new macros for database interaction: filldotrun.C, filldotrbk.C
1359
1360 - added new program which can convert colored output which was redirected
1361 into a file back into colored text (for example to display it with
1362 more): showlog
1363
1364 - added new program to display an MStatusArray of plots (stored with
1365 MStatusDisplay) from a file: showplot
1366
1367 - Added support for Sequences (MSequence). Sequences are blocks of run
1368 files containing the same calibration and belonging to the same
1369 source
1370
1371 - Added a new task (MTaskEnv) which can be used in setup files to switch
1372 between different tasks (for example to choose a signal extractor)
1373
1374 - Implemented automatic file splitting in MWriteRootFile
1375
1376 - After image cleaning an island index is assigned to all used pixels.
1377 The index corresponds to the order of the islands in size.
1378
1379 - added a cleaning which takes signal height _and_ arrival time into
1380 account: probability cleaning (for more details see MImgCleanStd)
1381
1382 - added a cleaning which takes takes the absolute number of photons
1383 times the area ratio as cleaning level
1384 (for more details see MImgCleanStd)
1385
1386 - Changed calculation of image parameters such, that it can be done
1387 for all used pixels or the pixels with a defined island index only
1388
1389 - implemented new image parameters displaying the number of islands,
1390 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1391
1392 - event display in executable changed to support also calibrated files
1393 (done with MJCalibrateSignal)
1394
1395 - added program doing the calibration and the signal extraction
1396 and signal calibration: callisto Most part of the setup is done
1397 by a resource file: callisto.rc
1398
1399 - implemented support for pixels with negative IDs (Raw file format
1400 version 4)
1401
1402 - implemented an new option in merpp (--auto-time) to get the time
1403 range for cc and/or caco data from the run header of the raw data
1404
1405 - New star-program (star and MJStar). Taking calibrated data from
1406 callisto/MJCalibrateSignal as input. The setup is done through
1407 a resource file: star.rc
1408
1409 - Added possibility to setup the eventloop in the mars-executable
1410 Camera Display by a resource file: mars.rc
1411
1412 - The the mars-executable Camera Display can now also read
1413 calibrated data files written by callisto/MJCalibrateSignal
1414
1415 - Added a new class which can calculate the source position in
1416 the camera from a pointing model known to be correct and
1417 the pointing model used for observations (MSrcPosFromModel)
1418
1419 - added a new version of the class calculating the effective on-time
1420 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1421 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1422 MHTimeDiffTheta.
1423
1424 - added the possibility to count how often a signal is above (or
1425 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1426 can replace MHTriggerLvl0)
1427
1428 - added ore convinient ways to set the axis-titles of your histograms
1429 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1430 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1431
1432
1433
1434 *** Version 0.8.5 (2004/08/06)
1435
1436 - new Signal Extractors: MExtractFixedWindowSpline
1437 and MExtractAmplitudeSpline
1438
1439 - implementes interleave in merpp to be able to merpp parts of a file
1440
1441 - implemented force-functionality to merpp
1442
1443 - star display to display star catalogs (MAstroCatalog)
1444
1445 - star display to 'mirror' stars to the camera (MAstroCamera)
1446
1447 - implemented a new cleaning option which allows cleaning scaled with
1448 the real ratio of the rms depending on the pixel size, not only the
1449 square root of the pixelsize (MImgCleanStd, MCameraData)
1450
1451 - removed obsolete MBlind* classes
1452
1453 - Signal extractor taking the AB flag into account implemented (this makes
1454 an odd number of slices for signal extraction possible
1455 (MExtractSignalABcorr)
1456
1457 - implemented a class extracting the pedestal from the raw-data (events)
1458 itself using empty lo-gain (MpedCalcFromLoGain)
1459
1460 - Added mean values to MPedPhotCam
1461
1462 - Added Makefile for Darwin (this OS is NOT officially supported!)
1463
1464
1465
1466 *** Version 0.8.4 (2004/04/19)
1467
1468 - new fast arrival time extractor using cubic splines:
1469 MExtractTimeFastSpline
1470
1471 - implementes multi-argument support in MDataChain
1472 ("pow(a, b)")
1473
1474 - implemented double reference support in MDataChain
1475 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1476
1477 - added support in MF for expressiond like
1478 "MHillas.fWidth<2*<MHillas.fLength"
1479
1480 - MDataChain is now able to support variables like [0], [1], ...
1481 which can be used in fit functions as parameters. The interface
1482 is implemented through the new virtual function
1483 MParContainer::SetVariables
1484
1485 - added new class MArrivalTimeCam/MArrivalTimePix:
1486 Storage containers to hold the ArrivalTime of the camera/pixel
1487
1488 - added new classes for the calibration of relative arrival times:
1489 MCalibrationRelTimePix and MCalibrationRelTimeCam
1490
1491 - added new classes to extract the signal of the blind pixel and the
1492 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1493
1494 - added new classes for the bad-pixels treatment (MBadPixels*)
1495 which are more powerfull than the old ones (MBlindPixel*)
1496 and will replace them.
1497
1498 - added filter against cosmics: MFCosmics
1499
1500 - added new class MArrivalTimeCalc2:
1501 Calculates the arrival time as the signal weighted mean of the time
1502 slices in the maximum window
1503
1504 - added a new macro call pointspreadfucntion.C that fits with a 2D
1505 gaussian the DC spot for an star. It gives you the RMS of
1506 the PSF and the center of the star, very useful for misspointing
1507 studies.
1508
1509 - added support for multi-telescope camera files. Added classes
1510 MStereoCalc and MStereoPar, classes to calculate and store shower
1511 parameters calculated from the data of two telescopes, for the MC
1512 studies regarding the MAGIC clone.
1513
1514 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1515 MC data calibrated in photons instead of ADC counts.
1516
1517 - added three macros to show the calibration and analysis chain of
1518 MC data. The macro starmc.C does both calibration and analysis, producing
1519 an output containing Hillas parameters for each event. The macro
1520 mccalibrate.C does just the calibration and writes out a file containing
1521 pixel information in photons instead of FADC data. The macro starmc2.C
1522 reads in such a file and produces an output with Hillas parameters.
1523
1524 - added MPedPhotCalc to compute pedestals in units of photons, see
1525 macro pedphotcalc.C
1526
1527 - added all class to perform the calibration, see macro calibration.C
1528
1529 - added class MFFT to perform Fast Fourier Transforms
1530
1531 - added class MSimulatedAnnealing to perform simulated annealing
1532 minimizations
1533
1534 - added new macro bootcampstandardanalysis.C which holds the skeleton
1535 of the analysis chain discussed in the december bootcamp.
1536
1537 - added support for DAQ raw data file format V2
1538
1539 - implemented an arbitrary time stamp for the events from raw-data
1540 files with file version<3. It is calculated from the run number,
1541 the date of start and the FADC clock tick from the first module
1542
1543 - implemented the correct decoding of the event time-stamp
1544 coming from the DAQ for raw-data files with file-version>2
1545
1546 - added a new classes storing the pedestals in units of photons:
1547 MPedPhotPix, MPedPhotCam
1548
1549 - added support for DC current files from the camera control
1550
1551 - added support for start- and stop-time when merpping report files
1552
1553 - added MReportCC storing the weather data from the CC-REPORT
1554
1555 - added class to fill trainings and test matrices (MTFillMatrix)
1556
1557 - added a filter performing a software trigger (MFSoftwareTrigger)
1558
1559 - Added classes to perform parts of the standard analysis (Jobs):
1560 + MJPedestals
1561 + MJCalibration
1562 + MJExtractSignal
1563 Note: All of them are preliminary!
1564
1565 - Added Iterator to iterate over files giving only the run-number
1566
1567 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1568 the evolution of a sector vs time
1569
1570
1571
1572 *** Version 0.8.3 (2003/12/05)
1573
1574 - adapted Random Forest classes to allow the use with MC
1575 multi-telescope files which can be produced with the coming
1576 camera version 0.7.
1577
1578 - added classes to read and interprete central control report files
1579 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1580
1581 - enhanced merpp (the executable) to support .raw and .rep files.
1582
1583 - added classes for light calibration (MCalibration* and
1584 MHCalibration*) by Markus Gaug. Further work has to be and will
1585 be done soon.
1586
1587 - Added a preliminary 'synchronizer' (MReadReports) which will
1588 replace MReadMarsFile as soon as it is finished.
1589
1590 - Added a tutorial macro demonstrating how report files are merpped
1591 and how they can be read from the root file in the correct order
1592 of time (readrep.C)
1593
1594 - Added a generalized histogram (similar to MH3) called MVsTime
1595 which allows to plot variables (or rules - MDataChain - of
1596 variables) vs time. For an example have a look at tempvstime.C.
1597
1598 - Changed the name of the event trees:
1599 + Events --> Events
1600 + PedEvents --> Pedestals
1601 + CalEvents --> Calibration
1602
1603 - changed name of MTime in the event trees from MRawEvtTime to MTime
1604
1605 - added displaying the sector indices to the mars event display
1606
1607 - Magic Online Analysis (MOnA) implemented in a first version
1608 (see mona.cc, MOnlineDump and MOnlineDisplay)
1609
1610 - added classes to calculate event rate
1611 (preliminary: MEventRateCalc, MEventRate)
1612
1613 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1614
1615 - added classes dealing with the telescope pointing position (MPointing*)
1616
1617 - implemented the 'final' Mars time stamp based on some experiences with
1618 the new 'Synchonizer'
1619
1620
1621
1622 *** Version 0.8.2 (2003/11/10)
1623
1624 - accelerated standard analysis by a factor of 6-8 ...
1625 + doing precalculations in MGeomCam for the pixel area ratio
1626 + creating a look up table for the single pixels in MCerPhotEvt
1627
1628 - added task to calculates weights in case you want to 'change'
1629 the energy spectrum of a monte carlo file
1630 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1631
1632 - added a new executable star which implements the
1633 star.C macro as precompiled executable. Currently a flexible
1634 setup is not possible, but a 'input card' setup will follow.
1635
1636 - Starting to implement Multi-Telescope-Support based on the
1637 upcomming camera version 0.7. The base for a general support
1638 is implemented and the star-functionality is proven to work.
1639
1640 - Replaced Event-Display in and Camera-Display in the Mars GUI
1641 executable by a more convinient display base on MStatusDisplay.
1642
1643 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1644
1645
1646
1647 *** Version 0.8.1 (2003/10/20)
1648
1649 - added signal subtraction for pure on data by means of fitting
1650 the background in the off region or by performing a combined
1651 signal/background fit. Provides necessary histograms for
1652 obtaining energy spectra and a light curve.
1653
1654 - added classes to perform and study the selection of the
1655 2nd Level Trigger on MC data (example in triglvl2.C macro)
1656
1657 - added pedestal calculation
1658
1659 - implemented "democratic cleaning" (tail cut value proportional
1660 to pixel area) according to Wolfgang's suggestion.
1661
1662 - added Sigmabar treatment (calculation and basic histogramming)
1663
1664 - added basic routines to apply padding
1665
1666 - added first implementation of MARS-based source visibility plotter
1667 (needs to be linked against slalib, preliminary version)
1668
1669 - enhanced functionality of data chains: random numbers, conversion
1670 functions and access to MHMatrix objects
1671
1672 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1673 numbers under certain circumstances (runs with 0 events included)
1674
1675 - fixed a bug in the general filter MF (didn't work on some systems
1676 at all)
1677
1678 - fixed a bug in chaining files, which caused the analysis to crash or
1679 ignore files
1680
1681 - implemented more geometry classes describing the parameters used
1682 to simulate the PMT camera
1683
1684 - added new Monte Carlo classes containing the setup of the different
1685 programs in the MC chain.
1686
1687 - added a (preliminary) general task to evaluate chi-square of a given
1688 parameter in an eventloop.
1689
1690 - first implementation of a container describing the observatory
1691 location (Long, Lat, etc)
1692
1693 - added Random Forest - method for g/h-separation
1694
1695 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1696 (this means, that it is compiling, but not yet fully tested)
1697
1698 - added a new status display which can show the present status
1699 of histograms while an eventloop is running (MStatusDisplay,
1700 an example can be found at status.C)
1701
1702 - reorganized directories:
1703 classes describing the image --> mimage
1704 classes containing Monte Carlo Histograms --> mhistmc
1705 classes for Random Forest method --> mranforest
1706
1707 - added (event-)weights to fill histograms
1708
1709 - colors in logging output to screen
1710
1711 - changes to the Image Parameter declaration:
1712 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1713 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1714 + MHillasExt now derives from MParContainer instead of MHillas
1715 --> Files written with the old definition are more or less unreadable
1716
1717 - reading of reflector files
1718
1719 - display data from reflector files in the camera
1720
1721 - implemented currents (and display them in the camera)
1722
1723 - logarithmic scale in camera
1724
1725 - added class to iterate through directory contents (MDirIter)
1726
1727
1728
1729 *** Version 0.8 (2002/11/18)
1730
1731 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1732
1733 - corrected 48(!) wrong entries in the Next Neighbor table of the
1734 Magic Camera (all in the inner part of the outer ring, mostly
1735 missing a single NN)
1736
1737 - Fixed a bug in the table describing the Next Neighbours of the
1738 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1739 have any neighbour)
1740
1741 - changed trigrate.C: now it calculates the pure NSB triggers from
1742 a camera file (generated with no showers), so there is no need
1743 to introduce them by hand in the BgR array (for more details
1744 please ask Abelardo)
1745
1746 - added MHHadronness (and MHadronness) as a general facility to evaluate
1747 the quality of a gamma-hadron seperation method
1748
1749 - changed MWriteAsciiFile to accept rules (MDataChain)
1750
1751 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1752 must be replaced by calles to MWriteAsciiFile::AddColumn and
1753 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1754 changed.
1755
1756 - Implemented generalized event-matrices (one row per event)
1757 (MHMatrix)
1758
1759 - implemented the one dimensional composite probabilities
1760 (MHCompProb, MCompProbCalc, comprob.C)
1761
1762 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1763 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1764
1765 - Added a camera display displaying the pixel numbers to the
1766 event display gui.
1767
1768 - Added Monte Carlo Informations to event display gui
1769
1770 - Changed the camera display to display the pixel numbering
1771
1772 - Added three buttons to the camera display to change the palette
1773
1774 - Added the number of used and core pixels after image cleaning
1775 to MHillas
1776
1777 - Changed the algorithm used in MHillas according to TDAS 02-03
1778
1779 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1780
1781 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1782
1783 - Added fCosDeltaAlpha to MHillasSrc
1784
1785 - The numbers of photons used to calculate fConc and fConc1 in
1786 MHillasExt are now scaled with the pixel size, so that one get
1787 a four times smaller value for the bigger pixels in the outer ring.
1788
1789 - added new task to smooth the camera contents (MCameraSmooth)
1790
1791 - added possibility to use interpolated pixel values for blind pixels
1792 instead of removing it completely from the analysis
1793
1794 - Implemented the possibility to save the whole eventloop with
1795 its setup to a file. This information can be read and from
1796 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1797 and MEvtLoop::MakeMacro. If you find something not working, please
1798 report - this stuff is still in a beta phase.
1799
1800 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1801 file having crab starfield, but also for all following files - fixed
1802
1803 - MTaskList::PrintStatistics can now be instructud to print also the
1804 title, too: use PrintStatistics(0, kTRUE)
1805
1806 - Changed the image cleaning so that pixels with to many 'used'
1807 neighbors are left used (to get rid of 'holes' in events)
1808
1809 - Introduced more output to the camera displays
1810
1811 - Added an array of histograms (eg one hist per run), MHArray
1812
1813 - Added a _preliminary_ version of the reader for CT1 PreProc files
1814 (MCT1ReadPreProc)
1815
1816 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1817 (thanks to Raquel)
1818
1819 - added the first energy estimator (MEnergyEstParam, estimate.C,
1820 estfit.C) using a parametrization
1821
1822 - Added some new Monte Carlo paremeter containers used to store
1823 setup information from the MC chain (MMcConfigRunHeader,
1824 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1825
1826
1827
1828 *** Version 0.7 (2002/04/30)
1829
1830 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1831 the pedestal mean value was saved incorrectly. For files from
1832 this versions we substract 0.5 from the pedestal mean.
1833 WARNING: This may effect your results, so don't wonder...
1834
1835 - First implementation of an algorithm using only triggered events
1836 for the collection area calculation
1837
1838 - Ascii Output can now also be used for parameter containers which
1839 doesn't overload MParCointainer::AsciiWrite
1840
1841 - The Ascii Output is now also capable of writing single data members
1842 of one container
1843
1844 - You are now able to change the order of the values written to the
1845 ascii file
1846
1847 - You can now specify a conversion factor for each data member written
1848 to an ascii file. This may be usefull to change the units of the
1849 data member (eg. degrees instead of millimeters in case of the
1850 hillas parameters)
1851
1852 - Replaced old MHillas by a new structure which allows you to extend
1853 the parameters stored in MHillas very easily:
1854 see MHillas and MHillasExt
1855
1856 - Added classes to handle source dependancy of image parameters:
1857 see MHillasSrc
1858
1859 - Added container (MBinning) to have a standard input for the binning
1860 in different histograms (eg. the Energy bins should be the same in
1861 all histograms)
1862
1863 - Changed Hillas histograms from mm to deg
1864
1865 - Added the flexible binning to the hillas histograms
1866
1867 - Added a filter for the alpha parameter (MFAlpha)
1868
1869 - It is now possible to write single data members of a class object to
1870 an output stream instead of the whole container only
1871
1872 - Added a generalized filter for a data member:
1873 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1874
1875 - Added a generalized Filter parser for more difficult filter rules
1876 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1877
1878 - Added new Monte Carlo histograms:
1879 MHMcEnergyImpact and MHMcEfficiency
1880
1881 - Added many new histograms needed for the flux calculation.
1882
1883 - Added a generalized histograms which can fill and show up to three
1884 data members in either a one-, two- or three-dimensional histogram, eg:
1885 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1886
1887 - Added:
1888 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1889 * calculation of <Theta> as a function of time (MHThetabarTime)
1890 they are needed in the flux calculation in
1891 order to select for a given bin in Theta (or time) the appropriate
1892 effective collection area, which is assumed to be given as a function
1893 of Theta and the true energy
1894
1895 - Added calculation of the migration matrix in the energy
1896 (MHMcEnergyMigration):
1897 the migration matrix describes the migration from the true (E_true)
1898 to the estimated energy (E_est); it is needed to determine the
1899 distribution of E_true from the measured distribution of E_est
1900 by unfolding
1901
1902 - changed the color palette in the camera display to DeapSea.
1903
1904
1905
1906 *** Version 0.6 (2002/01/15)
1907
1908 - Introduce the option of disable pixels (MBlindPixels and
1909 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1910 able to deal with Star Field NSB.
1911
1912 - Fixed a bug in the pedestals substraction
1913
1914 - Introduced verbosity levels
1915
1916 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1917
1918 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1919 work correctly (thanks to Abelardo)
1920
1921 - Introduced correct treatment of the diffuse Night Sky Background
1922 and NSB (MMcPedestalNSB)
1923
1924 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1925
1926 - Introduced MMcRunHeaders which contains monte carlo run informations
1927
1928 - Added a 'Print'-Task (MPrint) which calls the Print function
1929 of a parameter container for each event
1930
1931 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1932
1933 - changes to be more efficient with root 3.02/06
1934
1935 - root 3.02/06 fixes:
1936 + the memory leak when reading MRawEvtData
1937 + loosing more time than necessary to update the progress bar
1938
1939 - MWriteAsciiFile is now capable of writing more than one container
1940 in a line. For example: To be able to write Monte Carlo and
1941 Hillas values (energy and alpha) in one line.
1942
1943
1944
1945 *** Version 0.5 (2001/11/06)
1946
1947 - Added new GUI functionality (Analysis)
1948
1949 - Added a camera display to be able to display events in the camera
1950 together with the calculated hillas ellipse
1951
1952 - Added a 'Clone'-Task (MClone) which can clone a parameter container
1953 object at any state of the analysis, so that the output are several
1954 states
1955
1956 - Fixed a bug in the collection area error calculation
1957 (Thanks to Ciro and Abelardo)
1958
1959 - Fixed a bug which causes merpp to crash in some environments
1960
1961 - Implemented auto enabling scheme for Branches to speed up reading
1962 a lot (see MReadTree and MTask)
1963
1964 - Fixed a bug in the Histogram classes which caused histograms to
1965 be written to a file by MWriteRootFile without request
1966
1967 - changed the object I/O from the old stylish root I/O to the new
1968 'auto evolution scheme' This was done only for classes which are not
1969 yet used in Monte Carlo files, so that these files are still readable.
1970
1971 - Added support for a progress bar in MEvtLoop and MReadTree
1972 (see the Analysis Window in Mars for an example)
1973
1974 - Fixed a bug in the package creation which disturbed the conversion
1975 between a mars version unpacked from a tar file and the repository.
1976
1977 - Changed the code to writer merpped (converted into root format)
1978 raw files, to get faster (around 10%)
1979
1980
1981
1982 *** Version 0.4 (2001/09/20)
1983
1984 - This release is made to compile on a root version >= 3.00
1985
1986 - Fixed a bug which causes MReadTree to read the first file only
1987
1988 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
1989
1990 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
1991
1992 - Added a task to write several container to a root file (MWriteRootFile)
1993
1994 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
1995
1996 - Added calculation of the collection area (MMcCollectionAreaCalc)
1997
1998 - fixed some bugs in the Hillas calculation
1999
2000 - added filters to be able to control the task execution dependent on
2001 a parameter (for example: the number of level 1 triggers in a MC-file)
2002
2003
2004
2005 *** Version 0.3 (2001/04/23)
2006
2007 - Many demo macros added
2008
2009 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2010
2011 - Hillas Calculation added
2012
2013 - Standard image cleaning available
2014
2015 - MReadTree is now able to handle more than one file
2016 (Remark: of the same structure)
2017
2018 - Now we are able to display events in a first version of the
2019 Camera event display. To do this we must run the macro
2020 "macros/readCT1.C" to read data from CT1.
2021
2022
2023
2024 *** Version 0.2 (2001/01/24)
2025
2026 - First Implementation of a Gui to read the raw data. Start the
2027 gui with the command mars.
2028
2029
2030
2031 *** Version 0.1 (2000/12/20)
2032
2033 - First official release 0.1
2034
2035 - Changes:
2036
2037 + changed calling style of MRawPixelIterator from do...while to
2038 while-loop
Note: See TracBrowser for help on using the repository browser.