source: trunk/MagicSoft/Mars/NEWS@ 8296

Last change on this file since 8296 was 8293, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 84.5 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: Website to plot values from the database has been added.
6
7 - general: The changes to the interpretation of phrases lead to
8 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
9
10 - general: Added a possibility to display grouped data in the plotdb.C
11 macro (and similar macros). This allows to plot hourly, nightly,
12 weekly, monthly and yearly averages.
13 For more details see the plotall function of the macro
14
15 - general: fixed the error display of the camera display. It showed
16 wrong results.
17
18 - general: fixed a memory leak when reading many MStatusDisplays
19
20 - callisto: Redone the signal extraction this includes:
21 + Unified the algorithms to extract the pedestal for all pedestal
22 extractions done
23 + Unification of hi- and lo-gain into one array
24 + Unification of hi- and lo-gain extraction for Spline and
25 Digital Filter (means now exactly the same algorithm is used,
26 not a copy-and-pasted one)
27 + Store pedestal subtracted data in a common place
28 + Improved extraction algorithms. If the algorithms search a
29 maximum but don't find one they don't return the maximum anymore
30 + Improved the extraction such that a information for signal
31 and time which is consistent is returned
32 + replaced the numerical spline with a (not slower) analytical
33 solution
34 + Lowered the saturation limit from 250 to 245 to make sure that
35 we are far away in all pixels from problems with the clock-noise
36 + The start of the lo-gain extraction is calculated from the hi-gain
37 arrival time. In case of saturation an estimation is used.
38 + the hi-gain window was extended to slice 16. This allows extraction
39 of very late pulses in single pixels or of huge hadron showers.
40
41 - callisto: New hi-/lo-gain calibration constants have been produced
42 for all periods from the statistic of the whole period. They are
43 now used automatically depending on the periods. The old constants
44 where deviation in avarega about 2%-3%. The constants are very
45 stable from period to period (<<1%) except for exchanged channels.
46 In a few cases the constants used so far were off by 1%-2% (maybe
47 temperature effects?)
48
49 - callisto: To gain obsolete space we do not write the
50 MPedestalFundamental anymore. Also calibration and bad pixel
51 treatment is not done for it anymore because it has never been used.
52
53 - callisto: Fixed a bug in the seuqence handling which caused the
54 light condition to be ignored
55
56 - optim: fixed a problem with the optim-macros which was due to a bug
57 in the new phrase parsing
58
59 - ganymed: To get a nice FalseSource plot (instead of the all-information
60 debug plot displayed as a standard plot) use the context menu
61 somewhere between the two upper plots, click on "DrawNicePlot"
62 and enjoy the result. (It is the same context menu which contains
63 the other options)
64 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
65
66 - ganymed/optim/train: The cut program, trainings- and optimization
67 macros could run with less files found than expected from the
68 sequence-files. No the execution is stopped in this case.
69
70 - ganymed: now stores the dataset in the output file with all information
71 contained (as sequence number, sequence path, data path) so that the
72 used dataset file can be recreated complete from the output
73
74 - sponde: now also allows the uasge of random forest
75
76 - sponde: added a plot showing the cut efficiency
77
78 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
79 errors (eg. effecting the collection area) because the errors of the
80 two histograms were swapped in the calculation, which makes a difference
81 in the case the histograms contains weighted events. Aditionally the
82 totalarea was incorrectly taken into account, which results in too small
83 errors, which makes a difference at low statistics were the errors
84 or the collection area dominate.
85
86
87
88 *** Version 0.10.3 (2006/10/23)
89
90 - database: Implemented ObservationMode flag in websites.
91
92 - database: For sequences there is now also the stoptime available on the
93 websites.
94
95 - database: Removed ManuallyChanged flag from sequence-info websites,
96 as it is not needed anymore with the new sequence building algorithm.
97
98 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
99 Class for calculation of confidence intervals (upper limits).
100 Use model 3 or 4 for upper limit calculation for MAGIC observations.
101 Please read the class instruction of TRolke for more information.
102
103 - general: The programs now return 0xfe if the requested resource file
104 doesn't exist.
105
106 - general: Errors comming from root itself are now not output to
107 stderr anymore but to our default (colored) log-stream.
108
109 - general: Changed the interface to TFormula such that now everything
110 is parsed by TFormula, which should allow to use phrases even
111 without paranthesis correctly parsed.
112
113 - callisto: replaced the AdHoc number of effective integration slices
114 in the digital filter by an average of the correct number, averaged
115 over all possible set of weights. This also gives correct numbers
116 for the lo-gains which were totally wrong before.
117
118 - callisto: drastically reduced memory consumption by not storing
119 all intermediate calibration results in memory anymore (we might
120 write them into a file in the future)
121
122 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
123 debug plot displayed as a standard plot) use the context menu
124 somewhere between the two upper plots, click on "DrawNicePlot"
125 and enjoy the result. (It is the same context menu which contains
126 the "DrawAll" option)
127 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
128
129
130
131 *** Version 0.10.2 (2006/10/15)
132
133 - general: changed the building of the sequence files such, that
134 the source-/project name in case of wobble-sources is not the
135 source/project of the first data run anymore but the new generalized
136 wobble source/project
137
138 - general: Added some functions to MAstro to calculate sun and
139 moon properties
140
141 - general: Added two new macros (starvisday.C and starvisyear.C)
142 which allow to plot the visibility of several stars in one day
143 or of one star along one year
144
145
146
147 *** Version 0.10.1 (2006/10/11)
148
149 - general: HTML logging output was distorted... fixed.
150
151 - general: Changed the writing of the sequencefiles such that only
152 as many pedestal files as giving at least 1000 pedestal events which
153 are nearby the first calibration run are used as pedestal runs
154
155 - sponde: In the calculation of the collection area(s) and the
156 distribution for MOnte Carlo and estimated energy the error
157 calculation was wrong because root didn't take the errors
158 properly into account... fixed.
159
160
161
162 *** Version 0.10 (2006/10/10)
163
164 - general: all executables now check consistency of the root version
165 installed with the root version used for compilation. The return
166 code in this case is 255.
167
168 - general: The algorithm to build seqeunces has been redesigned
169 completly. It is now more flexible in terms of a resource file
170 resources/sequences.rc which can be used to partly overwrite
171 the default algorithm and defined the important part of the
172 algorithm. It also takes correctly into account several ways
173 of taking wobble-data. Currently the new algorithm doesn't take
174 the number of pedestal events anymore into account (so a sequence
175 could have much less than 1000 pedestal events and data runs are
176 no-more used instead)
177
178 - general: a lot of small changes to make the code compatible with
179 root 5.12/00 and gcc 4.1
180
181 - general: Fixed some warnings thrown if more warnings are switched
182 on in the compiler
183
184 - general: Added a function to MMath which returns the Median of
185 the distribution abs(y[i]-median) but at 68:32 division instead
186 of 50:50, which is somehow the median counterpart of the rms.
187
188 - general: MAstroCatalog allows now to read calatog files (as bsc5)
189 even if they are compressed with gzip (recommended compression
190 is with "-1")
191
192 - showplot:
193 + batch mode creation of image files now works with root 5.12/00
194 + added support for writing bmp (though it never produces
195 bmp which can be read by programs like xv or gimp)
196 + added support for xml
197 + added new option to start the display with a different size, by
198 --display-width=nnn or --display-height=nnn
199 + added options to define the canvas size when the display is started
200 --canvas-width=nnn or --canvas-height=nnn
201 the option can also be used for batch-mode conversion
202 + added an option which automatically fits the display size to the
203 desktop-size: --auto-size
204
205 - merpp: didn't recognize files with the extension .raw.gz - fixed.
206
207 - merpp: allow the reports to have 1000ms due to a bug in the camera
208 program.
209
210 - callisto: New swapped pixels have been found and corrected. For
211 details see MRawRunHeader::FixAssignment()
212
213 - callisto: Callisto now raises an error if one of the input files could
214 not be opened.
215
216 - callisto: In some rare cases it could happen that in the signal
217 extraction of the digital filter the extractor returned nonsense
218 results due a wrong initializion of a variable (this happens in
219 cases in which the extracted signal is exactly zero or the
220 digital filter couldn't slide because of a too small extraction
221 window, which could happen in the lo-gain extraction)
222
223 - callisto: The lo-gains have been marked as valid in some cases
224 when they got not extracted at all (deltsumlo=deltatimelo=0) because
225 the allowed extraction range (fLoGainLast-fLoGainFirst) was
226 smaller than the number of slices (fLoGainWindowSize) needed
227 by the lo-gain extractor
228
229 - callisto: Updated absolute calibration constants (muon calibration)
230
231 - callisto: fixed a bug which caused the hi-gain saturation not
232 to be handled properly in the spline (the position of the
233 saturation was calculated incorrectly)
234
235 - callisto: fixed a bug which gave weird results if hi- _and_
236 lo-gain could not be extracted properly. In some cases hi-
237 and lo-gain have not been extracted at all and the random result
238 got calibrated. In other cases the hi-gain was saturating and the
239 lo-gain has not been extracted. For this a completly arbitraty
240 scale factor was applied to the result from extracting the
241 charge of the saturating hi-gain.
242
243 - callisto: improves handling of extracted signal if lo- and/or
244 hi-gain could not be extracted properly. If no appropriate
245 calibration of either the signal or the arrival time is possible
246 the pixel is now markes as unsuitable instead of estimated.
247
248 - callisto: Fixed a problem in the spline extraction which gave
249 weird results if the signal was extracted from the first (and
250 highest) slice (as a workaround extraction from the first
251 slice has been forbidden)
252
253 - callisto: Fixed a bug regarding the use of the QE which doesn't
254 effect the result because the default is used anyhow.
255 (The bug was there since 14/07/2005)
256
257 - callisto: Changed the default for fgLoGainStartShift to -2.4
258
259 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
260 factors to be always 10 for all pixels as soon as the first
261 calibration update has happend.
262
263 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
264 was off by more than one slice (which gives wrong values for
265 pixels which have saturated the hi-gain) This was a problem
266 mainly for timing studies, not so much for the automatic standard
267 analysis. Also the values for the Spline have been changed slightly:
268 + Digital Filter from 1.70 to 0.95
269 + Spline from 1.39 to 1.30
270 The numbers were sorted out by an extensive test in the
271 test-database.
272
273 - callisto: Removed the tab showing the average calibrated arrival
274 time. It never gave useful information.
275
276 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
277 lo-gain pulse for data pulses if hi- and lo-gain have saturated
278 and both were extracted because the hi-gain was above the
279 LoGainSwitch.
280
281 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
282 lo-gain pulse position (after application of LoGainOffset, which
283 means in the ideal case it is 0) for data pulses if hi- and lo-gain
284 have saturated and both were extracted because the hi-gain was above
285 the LoGainSwitch.
286
287 - callisto: After extensive tests a new threshold level for determination
288 of the pulse position has been found at 50phe. This is due to the
289 fact that for lower pulses the arrival time changes its average
290 behaviour dramatically. It tends to the average of the extraction
291 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
292
293 - callisto: Added two more plots to the calibration part. The average
294 extracted signal and the average extracted arrival time as
295 extracted by the signal extractor (This can help debugging problems
296 because it doesn't involve a fit)
297
298 - star: changed the fit for the effective on time such that initial
299 values are calculated automatically now instead of using build
300 in values. This makes the fit more indepedant of the underlaying
301 rates. With a test of ~350 sequences in the test database it could
302 be shown that the new fit gives the same result +/-1sek.
303 The highest deviation was +5s the lowest -10s. You can now control
304 the bahaviour with two resource values:
305 MHEffectiveOnTime.FistBin: 3
306 MHEffectiveOnTime.NumEvents: 12000
307 Use FirstBin=1 and NumEvents=120 to fit the effective on time
308 from the resulting gamma candidates
309
310 - star: The Center histogram in MHHillas is now by default displayed
311 with the colz draw-option
312
313 - ganymed: now produces valid error codes if failed
314
315 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
316 with the option "hadronness" instead of "area" or "both" if
317 you want to use both cuts. The hadronness cut includes a fixed
318 cut in hadronness (index 8) and a fixed cut in size (index 9).
319
320 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
321 the M3Long of the anti source to be not properly evaluated
322 (actually is was evaluated as a unique random number) in case
323 of optimization with anti-theta cut switched on. This might have
324 lead to improper, but not necessarily wrong, optimization results.
325
326 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
327 how to use random forest
328
329 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
330 ganymed_onoff.rc. Seems to be unintentional that they were different.
331
332 - sponde: Since the introduction of the possibility to define a
333 normalization energy instead of using the integral the default
334 was not using the integral anymore but a normalization energy of
335 1GeV. It is now the integral again.
336
337 - sponde: Fixed a problem in the weighting which did not allow
338 a MC slope of -1.
339
340
341
342 *** Version 0.9.6 (2006/05/24)
343
344 - general: changed the binning of the azimuthal profile of the camera
345 such that it is aligned with the 60deg boundaries.
346
347 - merpp: better handling of problems with the TH, TD part of the
348 CC-REPORT for files older than 200507190 and 200412210
349 respectively
350
351 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
352
353 - merpp: implementd latest changes in starguider reports (sinc 9th May)
354
355 - callisto: if an arrival time is extracted outside the fadc range is
356 was set to the boundary before. Now a random number is assigned
357 instead to avoid unfortunate coincidences of arrival times just
358 by this arbitrary value.
359
360 - callisto: added a new option to callisto.rc which allows
361 to set the maximum arrival time difference allowed for the
362 badpixel algorithm to determin whether a pixels belongs to a shower:
363 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
364
365 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
366 to 0.9 as suggested by Stefan due to a recent study on the fraction
367 of pixels surviving the image cleaning
368
369 - callisto: switched off error in case of "pulse is too much to the left"
370
371 - callisto: The extraction window is not adapted anymore. This means that
372 the pulse is extracted from the full range. The draw-back is that the
373 background (pedestal) will become slightly higher. Switching on/off
374 the PulsePosCheck in the callisto.rc only effects filling the
375 histograms.
376 WARNING: If the pulse is too much to the left data is calibrated!
377 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
378 in the database to make sure that your data is valid!
379
380 - star: Show also the number of stars correlated correctly by the
381 starguider
382
383 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
384 than one off-source region in wobble-mode. To use it add the following to
385 your ganymed_wobble.rc:
386 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
387 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
388 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
389 + Cut1.ThetaCut: None
390 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
391
392 - ganymed: in the case the latest report is older than a default (currently
393 one minute) and the current report will be skip the starguider
394 correction and calibration will be reset. The maximum age can be
395 setup from ganymed.rc by (minutes):
396 MPointingDevCalc.MaxAge: 1.5
397
398 - ganymed: A first implementation showing all size-bins for the theta-sq
399 resp. alpha-plots in a single tab automatically
400
401
402
403 *** Version 0.9.5.1 (2006/05/05)
404
405 - general: Added a new option "zdiff" to the Makefile which runs
406 "cvs diff" as "make diff" would do, but with compression
407
408 - general: accelerated MTFillMatrix (used for eample in all training
409 and optimization macros) by skipping some obsolete calles in the
410 eventloop the first and second loop could be accelerated by ~20%
411
412 - general: Added a missing feature in the MFilterList class which
413 prevented MFEnergySlope from working correctly in trainenergy.C
414
415 - general: Accelerated the random forest training and usage a bit
416
417 - merpp: Adapted to new raw data file format version 6
418
419 - merpp: fixed a problem with reading the starguider reports
420 after 6.3.2006
421
422 - callisto: At some times six pixels had to be exchanged manually in the
423 data. If the pixels to be swaped are both not found, an error was raised
424 and calibration was stopped. Now it is assumed they are intentially not
425 mapped and the Error has been changed to a Warning.
426
427 - star: Added new image cleaning based on the arrival time of the shower.
428 The new cleaning can be accessed using the parameter "Time" instead of
429 the the old one (like "Absolute) in the star.rc-file.
430 Recommended parameters:
431 + MImgCleanStd.CleanLevel1: 8.2
432 + MImgCleanStd.CleanLevel2: 5
433 + MImgCleanStd.CleanRings: 2
434 + MImgCleanStd.KeepSinglePixels: No
435
436 - star: Simplified the calculation of the effective on time. By letting
437 the fit start in the third bin the result should become more stable.
438 The fit quality is now ignored for the theta-plot which is not used
439 in the analysis later. Still better pre-cut which, for example,
440 remove events triggered by car-light (rate changing on a short
441 time-scale) are missing.
442
443 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
444 for optimization (kWeakSource) which is suggested by the Berlin
445 people for weak sources.
446
447 - macros: plotdb.C:
448 + if no dataset and no time-interval is given only sequences with
449 an effective on-time above five minutes are plotted anymore
450 + added a new tab "RelTime" displaying the relative on-time
451 (effective on-time divided by the observation time)
452
453 - macros: optim*.C: by skipping some obsolete calles in the eventloop
454 the optimization became a lot faster
455
456 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
457 To display them just delete the pads displayed on top.
458
459 - ganymed: fixed a bug which could cause strange behaviour in wobble
460 mode if no starguider information was available due to an incorrect
461 initialization of the starguider calibration
462
463 - ganymed: The scale region in the False Source Plot (MHDisp) can now
464 be changed from within the plot. It can also be setup from the
465 resource file using:
466 + MHDisp.fScaleMin: 0.325
467 + MHDisp.fScaleMax: 0.475
468
469 - ganymed, showplot: Fixed a problem with the fit to the off-data
470 (HistOff) which could cause a time lag or an inifinite loop.
471 The bug did not effect the results at all.
472
473 - sponde: Added a new tab showing the effective collection area after
474 trigger (including the software trigger)
475
476 - sponde: MMcSpectrumWeight has a new option which allows to define
477 the scaling factor not by the integral of the events but at
478 a defined energy:
479 e.g. MMcSpectrumWeight.NormEnergy: 200
480
481 - MTFillMatrix, sponde: by skipping some obsolete calles in the
482 eventloops the loop could be accelerated by ~20%
483
484
485
486 *** Version 0.9.5 (2006/03/13)
487
488 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
489 and added the standard Disp-parametrization
490
491 - macros: added a new macro datacenter/macros/plotstat.C allowing
492 to plot statistics about the data processing
493
494 - macros: added a new macro to plot the muon correction coefficients
495 versus period (macros/plot/mucal.C)
496
497 - showplot: path inflation for ganymed files was broken
498
499 - callisto: Fixed an important bug. When the number of saturating pixels
500 were calculated the bad pixel information already available from the
501 calibration was ignored. This yields wrong values in case pixels
502 are broken and saturate all the time or randomly.
503
504 - callisto: Updated Muon calibration constants. Spline data now also uses
505 different values for different periods
506
507 - star: The time-evolution shown in the effective on-time plot now displays
508 the axis range (if there are no holes it should be similar to the
509 effective on-time)
510
511 - star: Added two new image parameters:
512 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
513 the three pixels next to the center of gravity and the size
514 + MNewImagePar.fConcCore: The ratio of the signals of all
515 pixels inside or touching the ellipse and the size
516
517 - ganymed: now stops in requested source isn't found in catalog file
518
519 - ganymed: Many improvements to the phi-plot in wobble mode:
520 + with a template the ideal background is displayed
521 + a possible camera inhomogeneity is taken into account
522 + the anti theta cut is better supported
523 + the phi cut is automatically calculated from the theta cut
524 See the examples in ganymed_wobble.rc for more details.
525
526 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
527 times the bin-width instead of the absolute energy
528
529 - ganymed: New cuts for on/off and wobble mode
530
531 - ganymed: The smearing of the False Source plot has been increased
532 to 0.06
533
534 - ganymed: The starguider calibration can now be changed from the
535 resource file.
536 See the examples in ganymed*.rc for more details.
537
538 - ganymed: added a new option for on-/off-observations
539 MJCut.RandomSourcePosition
540 If switched on the distribution of observation time of the source
541 position in the camera is calculated from the on-data and randomly
542 applied with this distrbution to the off-data.
543
544 - ganymed: by skipping some obsolete calles in the eventloop the
545 first and second loop could be accelerated by ~20%
546
547 - ganymed: The default in ganymed_onoff.rc is now to determin the source
548 position in the off-data randomly according to its distribution in the
549 on-data.
550
551
552
553 *** Version 0.9.4.3 (2006/02/13)
554
555 - general: Fixed a bug in most of the programs which prevented the
556 compile date in the startup message to be displayed
557
558 - general: Simplified program calls. The following abbreviations
559 are now possible:
560 showlog callisto 55599
561 showplot signal 55599
562 star 55599
563 callisto 55999
564 ganymed 2
565 In this cases the corrsponding root-, log-, sequence- or dataset-
566 filename is automatically compiled using the default datacenter
567 paths ("/magic/*")
568
569 - general: Fixed a long outstanding bug which made axis tick marks
570 disappear if MDataFormula was used (eg. abs(x))
571
572 - general: Updated MMath with new functions to calculate the results of
573 a exponential, logarithmic and powerlaw fits analytically.
574
575 - general: Updated some macros with comments:
576 + macros/optim/optimdisp.C
577 + macros/optim/optimenergy.C
578 + macros/optim/optimwobble.C:
579
580 - general: MTFillMatrix (the class to fill one or two MHMatrix from
581 files) now allows adding a pre-cut like in the optimization. E.g. this
582 is useful to perform g/h-separation cuts before training the random
583 forest.
584
585 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
586 correctly assigned in the raw data assignement table. A fix to correct
587 the assignment tabel have been implemented.
588
589 - general: MAstroCatalog now allows rotating of the sky-grid and stars
590 by 90, 180 and 270 deg.
591
592 - general: the macro plotdb.C now allows to highlight sequences belonging
593 to a datset. For more details see the descritions in the macro.
594
595 - StatusDisplay: Fixed the algorithm to calculate the size ratio
596 of the display, it gave wrong results espacially for big sizes.
597 Now the embedded canvas should always have a ratio width/height=3/2.
598 The "Size" options have been updated with values fitting the 3/2
599 size ratio.
600
601 - RanForest:
602 + Updated the random forest classes to support also the
603 regression method implemented by Thomas H.
604 + added new tutorial macro how to train the random forest
605 for energy estimation (macros/optim/rfenergyest.C)
606 + new classes to train the random forest (still in development)
607 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
608 + new tutorial macros for random forest training in macros/train
609 trainenergy.C, traindisp.C, trainseparation.C
610
611 - mars: now allows to setup a cut in the resource file mars.rc to choose
612 the events to be displayed, eg:
613 Cut.Condition: {0} && {1}
614 Cut.0: MHillas.fSize>100
615 Cut.1: MHillas.fSize<900
616
617 - merpp: Made aware of the new .rep format 200510250. This includes
618 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
619 the discriminator thresholds (MCameraTD) and the disciminator
620 delays (MCameraTD). All of them come with the CC report and are therefor
621 written to the CC tree.
622
623 - callisto: fixed a bug in the calculation of the arrival times in
624 the Digital Filter. They were all shifted by the same amount
625 fHiGainFirst. This caused an offset in the order of the position of
626 the left border of the extraction window in the times calculated
627 from high-gain and from low-gain. The bug effected only the absolute
628 arrival times. The bug was there since 30.1.2005.
629
630 - callisto: Changed the ExtractionWindow for the pulse position check
631 such that the camera inhomogeneity becomes as less as possible and
632 comparable to the pulso position check switched off. More details
633 on the study will be given at our result web-page.
634
635 - ganymed: ganymed.rc, ganymed_onoff.rc:
636 changed to new cuts trained with 1ES1218 and Crab-data
637 for maximum sigma*log10(excess)
638
639 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
640 a new option was implemented to estimate Disp (CalcDisp)
641
642 - ganymed: Implemented two new options which allow
643 to overwrite the default path to search for the sequence files
644 --ins=/magic/sequences
645 and where to search for the image data
646 --ind=/magic/data/star
647
648 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
649 dx/dy from the resource file by
650 MSrcPosCorrect.Dx
651 MSrcPosCorrect.Dy
652
653 - ganymed: fixed reading the source catalog. Only as many chars
654 as the requested source name had were compared (If a source
655 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
656 were requested it could happen that the coordinates of
657 "1ES1218" were read) The source coordinates are now printed
658 in addition to its name to the logging output.
659
660 - ganymed: changed the background fit in the case of a ThetaSq function
661 from a polynomial to a exponential, this should give a big improvement
662 for on-only analysis'
663
664 - ganymed/sponde: Calculation of the error of single size-/energy-
665 bins now uses Li/Ma (5) instead of LiMa (17)
666
667 - sponde: Added a plot E^2*dN/dE
668
669 - sponde: The energy estimator plot should now show values like
670 they are commonly used.
671
672 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
673 (a powerlaw with cutoff didn't work before)
674
675
676
677 *** Version 0.9.4.2 (2005/10/01)
678
679 - general: added new tutorial macro macros/tutorials/threshold.C:
680 how to calculate the threshold
681
682 - general: added a new game. Start it from the interpreter with
683 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
684 and MagicReversi)
685
686 - general: neighbor pixels in MGeoms are now sorted clockwise
687
688 - merpp: made aware of new format 20050829-0
689
690 - callisto: New scale factors from muon analysis, stored in new
691 resource file resources/calibration.rc
692
693 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
694 the eventloop if something went wrong. This is necessary for the
695 automatic processing
696
697 - callisto: Implemented a new treatment for the time information
698 developed by S.Ruegamer, this should give much better response than
699 the old very primitive algorithm. This is especially important
700 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
701 treatment was buggy! As neighbor pixels to interpolate the
702 arrival times always the pixels 0 to 5 were taken)
703
704 - callisto: In addition to the new treatment of arrival times the
705 decision of the treatment whether a pixel contains shower
706 information or not is used to improve the signal interpolation
707 further. Previously interpolated pixels showed a non-zero signal
708 do the peak searching signal extractors. Having a signal pixel
709 beside raised the signal above the cleaning level. Thus the
710 pixel survived cleaning to often but with a too low mean signal.
711 By replacing empty pixels with a gaus (mean and rms from the
712 corresponding Area entries in MPedPhotCam) this effect can
713 be supressed.
714
715 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
716 got lost when the events were stored by the calibration... fixed.
717 (This was no problem for normal image cleaning because the pixel
718 content was artificially set to 0 not surviving standard cleaning
719 algorithm)
720
721 - callisto: Fixed a bug which caused the random and peak-search pedestal
722 extracted with an extractor to be exchanged for the first (roughly)
723 500 events (*Extractor and *ExtractorRndm).
724 (They were simply exchanged in callisto.cc) This bug might have been
725 introduced in Mars 0.9.4 when the order of calculation of the two
726 types of pedestal in callisto got exchanged. The bug only effects
727 the first seconds of data of each sequence.
728
729 - star: Taking the arrival time of Muons into account the calculation
730 of the parameters could be made independant of the noise
731 (pedestal rms). The dependance was due to the bias of the peak search
732 extractor. Now only a ZA dependamcy is left which is not yet fully
733 understood.
734
735 - ganymed: The sequences were still not sorted correctly in any case,
736 because they were sorted by the full qualified path name. Now they
737 are sorted by their sequence number.
738
739 - ganymed: new values for the spark-event-cut
740
741 - sponde: required missing MEnergyEst from ganymed.root... fixed.
742
743
744
745 *** Version 0.9.4.1 (2005/08/18)
746
747 - callisto: fixed some problems with the calibration in case of
748 inteleaved events. Therefor the final and some intermediate
749 fits are skipped which would take place on partly filled #
750 histograms and gave wrong results or failed completely.
751
752 - callisto: If the intermediate finalization of the histograms
753 calculating the mean charge of the calibration signal fails
754 it is counted now and printed in PostProcess of MCalibCalcFromPast.
755
756 - ganymed: Fixed some bugs which caused problems in On-only mode.
757 Still the false source plot doesn't give reasonable results.
758
759
760
761 *** Version 0.9.4 (2005/08/05)
762
763 - general: Fixed the ZA binning. It did not correctly fit the
764 MC binning
765
766 - general: Added a class to correct for the missfocussing in
767 April (MSrcPosCorrect)
768
769 - general: Random Forest energy estimator should now work properly
770
771 - general: MHCamera now displays the profiles in deg instead of mm
772
773 - general: MH::SetPalette offers a lot of new palettes
774
775 - general: MHillas - the case of CorrXY==0 is now handled properly
776
777 - general: implemented the possibility to change the line and
778 marker style of a sky-grid drawn by MAstroCatalog
779
780 - general: Runs in sequences and datasets are now automatically
781 ordered (it is assumed that the order of their filenames correctly
782 represents the order of observations) to ensure correct reading
783 of the subsystem data
784
785 - general: Runs cannot be added to a sequence twice anymore. Also
786 Sequences cannot be added twice anymore to a dataset.
787
788 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
789 It gave wrong results by 1./2pi
790
791 - showplot: got a new option to start a root interpreter, too
792
793 - mars: now displays a rough estimate of Disp and the third moment
794
795 - mars: now displays the event time MTime if available
796
797 - mars: show muon parameters graphically
798
799 - mars: now the file to open can be given as commandline
800 argument
801
802 - merpp: Added support for new arehucas version >= 200507190
803 implementing values for three temperature sensors in the
804 counting house (MCameraAUX) and the name of the HV settings file
805 (MCameraHV).
806
807 - merrp: Also fixed some problems with wrong versions numbers stated
808 by arehucas and implemented some fixed for old versions (<200407070)
809
810 - callisto: MCalibrationHiLoCam can now be printed from its context
811 menu, eg in the TBrowser
812
813 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
814 - 1.39 (MExtractTimeAndChargeSpline)
815 - 1.40 (MExtractTimeAndChargeDigitalFilter)
816 This is important mainly for timing studies.
817
818 - callisto: Changed limits in MHCalibrationChargeCalc from
819 - -100.125 to -98 (fgChargeHiGainFirst)
820 - 1899.875 to 1902. (fgChargeHiGainLast)
821 - -100.25 to -99 (fgChargeLoGainFirst)
822 - 899.75 to 901. (fgChargeLoGainLast)
823 Introduced new limits:
824 - fgNumLoGainBlackoutLimit: 0.05
825 - fgLoGainBlackoutLimit: 3.5
826 - fgLoGainPickupLimit: 3.5
827
828 - callisto: The handling of automatic weights for the digital filter
829 has been improved. There are now new calibration weights special
830 for Monte Carlo calibrations.
831
832 - callisto: Updated Muon scale with latest results (1% difference
833 for most data, 5% for Mar/Apr'05)
834
835 - callisto: use a new criterium to exclude bad pixels: If the high-gain
836 was saturated and the blackout-events in the low-gain exceed the
837 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
838 This excludes those pixels which have a saturating high-gain
839 channel, but the low-gain switch does not switch often enough
840 to make the distribution reliable.
841
842 - callisto: fix a bug counting the number of saturated events. Up to now,
843 the number of saturated slices was counted (which is one for a not too
844 high number), but for some (pathological) pixels, many more slices
845 saturated and produced wrong limits.
846
847 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
848 + MCalibrationRelTimeCam.CheckFitResults: Yes
849 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
850 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
851 + MCalibrationRelTimeCam.CheckOscillations: Yes
852
853 - callisto: introduce max. number of events for intercalibration,
854 the rest gets skipped. Default: 4096
855 The calibration causes too many un-reliable pixels if more
856 than about 5000 events are treated (@500 Hz) because of the
857 mode hopping of the VCSels. However, in the past, some
858 calibration runs have been taken (erroneously) with more
859 than 5000 events, especially the intensity scans where
860 a good precision is needed.
861
862 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
863 photo-electrons for the spline extractor by 1-2% (correctly).
864
865 - callisto: The intercalibration is now done using a full f-factor
866 method instead of a simple update. This makes things slower but
867 more reliable in terms of gain-fluctuations and sudden VCSEL gain
868 changes.
869
870 - callisto: MPedestalY3 now uses the same extraction range as the data
871 as calculated by MPedestalY2
872
873 - callisto: A check of the fraction of allowed unsuitable (10%) and
874 unreliable (30%) pixels has been addded when the conversion is
875 calculated from interleaved events
876
877 - star: fixed a bug which caused MEffectiveOnTime containers not to
878 be written. In the worst case they were skipped almost all, in the
879 best case they were all ok. It depends on how often the new value
880 was assigned just with an event which was skipped later by another
881 task
882
883 - star: new histograms MHPointing and MHRate
884
885 - star: New tab (Currents) displaying the time evolution of the mean
886 DC currents
887
888 - star: New tab (MeanRms) displaying the time volution of the mean
889 Pedestal Rms
890
891 - star: Output now contains MReportStarguider
892
893 - star: Improved muon analysis. Due to the absense of a constant
894 for the gaus fit for arc width and the fact that the arcwidth
895 plot was a histogram instead of a profile the resulting psf
896 became pedestal rms dependant
897
898 - ganymed: added new plot (MHPhi) for wobble mode as described in
899 http://www.astro.uni-wuerzburg.de/results/ringmethod/
900
901 - ganymed: corrects now (correctly?) for the misspointing in
902 May/April 05
903
904 - ganymed: Two new default templates for ganymed.rc are avilable:
905 ganymed_onoff.rc and ganymed_wobble.rc
906
907 - ganymed: The first version of MFMagicCuts has been released
908
909 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
910
911 - ganymed, sponde: There are two new options to determin the number
912 of bins for the signal region (NumBinsSignal) and the number of
913 total bins (NumBinsTotal) in the MHThetaSq histogram
914
915 - ganymed: optimized palettes for MHDisp
916
917 - ganymed: Fixed an important bug when using ThetaSq as fit function:
918 The result for the sigma of the gauss(sqrt(x)) fit was a factor
919 sqrt(2) to large
920
921 - ganymed: The false source plot (MHDisp) is now based on Disp
922 and a background model determined in the first loop is
923 subtracted
924
925 - ganymed: MFMagicCuts are now available in the cvs. The correct
926 solution for the disp ambiguity problem is now calculated using
927 the third moment. The third moment cut therefor is skipped.
928
929 - ganymed: Output now contains "Disp [MParameterD]" which sign is
930 already determined by the third moment along the major axis and
931 so its actual sign is aligned along the major axis of the shower.
932
933 - ganymed: If starguider data is available it is taken into account
934 when calculating the source position. This is especially important
935 for wobble data at high zenith angles and culmination data.
936
937 - ganymed: If available the starguider data is taken into account as
938 good as it is possible without a starguider calibration. To switch
939 it off add
940 MPointingDevCalc.MaxAbsDev: -1
941 to your ganymed.rc
942
943 - sponde: the zenith angle distribution is now weighted instead of
944 choosen by default. This gurantees higher statistics in the highest
945 and lowest energy bins. To switch this behaviour off use...
946
947 - sponde: now automatically displays the energy threshold
948
949
950
951 *** Version 0.9.3 (2005/06/03)
952
953 - general: MMcEvt now derived from MMcEvtBasic which should
954 have no influence on compatibility with older camera files
955
956 - general: Implemented a new option to MReadReports which allows
957 to force reading of the first event of some trees (eg. Drive-tree)
958 before any other tree.
959
960 - general: Made a fix to MPointingPosCalc which assumes that the
961 run-type is real-data if Process is called before ReInit, such
962 that also the very first Drive-events in a run are treated
963 correctly.
964
965 - shoplot now displays the filename in the title bar of the window
966
967 - merpp: new options: --auto-time-start --auto-time-stop which
968 allow to cut updating with slow-control at the start- or
969 (previousle --auto-time only allowed: and) stop-time of
970 the run stored in the runheader.
971
972 - callisto: changed default of fgFallTimeHiGain in
973 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
974 already set as default in callisto_Dec04Jan05.rc
975
976 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
977 now changes the filename for new weights automatically for
978 cosmics, MC and for different calibration colors.
979
980 - callisto: a problem with the order of some code cause the
981 name of the weights file in MPedestalY2 to be ignored.
982 Wrongly the calibration_UV weights were used instead
983 of the cosmics weights set in callisto.rc.
984
985 - callisto: should allow ct1 pulser data when the color is
986 explicitly set also for pretty new runs
987
988 - callisto: a new option (MCalibrateData.ScaleFactor) allows
989 to introduce an additional scale factor (should be around 1)
990 to adapt for slight deviations in different extractors from
991 the MC calibration. For MC calibrations the scale factor
992 is fixed to 1
993
994 - callisto: MFCosmics should handle very high signals a bit
995 more accurate now
996
997 - callisto: when calculating the mean pedestal rms for different
998 pixel sizes or sectors also kUnsuitableEvt is now taken into
999 account - not only kUnsuitableRun
1000
1001 - callisto: '-raw' option is now the default
1002
1003 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1004 This has the advantage that mean values in the calibration (eg
1005 arrival times) are calculated more accuratly.
1006
1007 - callisto: In the resource file callisto_Dec04Jan05.rc
1008 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1009
1010 - callisto: new Hi-/Lo-Gain intercalibration constants
1011 hilocalib_sp1.root and hilocalib_sp1_mc.root
1012
1013 - callisto: changed default for MJPedestalY2.MaxEvents
1014 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1015
1016 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1017 has changed from 9.0 to 6.0. This is necessary to exclude two very
1018 ringing pixels in September which - when kept - destroy the image
1019 cleaning around them (Markus G.)
1020
1021 - callisto: (!) The Muon analysis of all data taken so far has
1022 suggested that different extractors give slightly different
1023 absolute results after calibration, due to there different
1024 handling of the calibration- and cosmics pulse shape. Although
1025 the over all calibration seems to be a bit to pesimistic (or
1026 the MC seems to be a little bit - 3-5% - too much attenuated).
1027 There for correction factors have been introduced which correct
1028 the calibration constants by
1029 0.956937799 for Digital Filter (callisto.rc)
1030 and
1031 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1032 calibration. The main advantage is, that both data types can
1033 be easily analysed together and compared to the same MC sample.
1034 The factors are choosen such, that the reference is now a
1035 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1036
1037 - star: fixed a bug which caused the first bin of the histograms
1038 vs time to disapear in PostProcess. This gave wrong results
1039 on the screen. The output and all following programs not
1040 directly accessing the histograms haven't been affected
1041
1042 - star, ganymed: Made sure that always the first Drive-tree event
1043 is read and Processed before the first data event was read.
1044
1045 - ganymed: implemented the possibility to replace the standard
1046 false source plot with a different one. For example: If
1047 you want to use a Disp based FS plot use the resource:
1048 NameHistFS: MHDisp
1049 For details about the requirements of these plots look
1050 at the corresponding classes
1051
1052 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1053 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1054 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1055 case MAlphaFitter is setup correctly. For On-Only optimization
1056 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1057 RunOn() instead of Run(). For energy estimation MJOptimize
1058 has been replaced by MJOptimizeEnergy
1059
1060 - sponde: The input MC spectrum can now be weighted to fake a
1061 different spectrum. This is done via MMcSpectrumWeight. For
1062 more details see the class description and sponde.rc
1063
1064 - sponde: The paremeter comparsion plots are not scaled by
1065 their entries anymore. Instead the MC plot is scaled by using
1066 the result spectrum of the analysis. If the input MC spectrum
1067 and the result spectrum has different slopes the absolut
1068 normalization is normally wrong.
1069
1070
1071
1072 *** Version 0.9.2 (2005/05/20)
1073
1074 - general: Changed the default paths for calibrated data and image
1075 files. (The implemented access to these files doesn't yet exist)
1076
1077 - general: support for MRunIter has been removed from the job classes
1078 (use the setter functions of MSeqeunce instead)
1079
1080 - general: ProcessFile has been renamed to Process in all job classes,
1081 because ProcessFile is missleading
1082
1083 - general: The storage of the palette in MHCamera is now possible
1084
1085 - general: new bits describing unsuitable and unreliable pixels have
1086 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1087 kDeadPedestalRms, kFluctuatingArrivalTimes
1088
1089 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1090 versions newer than V200404070
1091
1092 - general: support for cc file versions newer than V200504130. Added
1093 support for active loads (MCameraActiveLoad) and central pixel
1094 (MCameraCentralPixel)
1095
1096 - general: added new histograms for image parameters versus size
1097 (MHVsSize)
1098
1099 - general: The eventloop now automatically calls PrintStatistics
1100
1101 - Status Display: Improved support for printing:
1102 + A default can now be set in .rootrc (for more details see
1103 MStatusDisplay::PrintPS)
1104 + A print dialog is opened so that printer and command line
1105 can be canged
1106
1107 - showlog: improved such that it handles different verbosity levels
1108 more accurate now. This mean you can suppress output when
1109 using showlog.
1110
1111 - showplot: improved
1112 + The new graphics formats have been implemented
1113 (pdf, svg, png, jpg and xpm)
1114 + Implemented an interface for printing. Because you can change
1115 the printing command from the command line you can use all
1116 the nice postscript tool. To print a booklet for example call:
1117 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1118 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1119 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1120
1121 - callisto: fixed a bug in the recognition of the calibration bit
1122 pattern. Concerns only intensity calibration. (The strength of the
1123 intensity has been updated in some cases)
1124
1125 - callisto: add a filter against PIN Diode events when running over
1126 calibration runs since some of the recent calibration runs have
1127 been taken with Pin Diode.
1128
1129 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1130 39943, 44833 in the calibration (MCalibColorSet)
1131
1132 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1133 been set to 1e-18 in callisto_Dec04_Jan05.rc
1134
1135 - callisto: in callisto_Dec04Jan05.rc: set value for
1136 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1137 statistics for the calculation of the mean pulse time
1138 of the cosmisc
1139
1140 - callisto: the charge limit in the calibration has been raised
1141 from 2.5 to 4.5
1142
1143 - callisto: new setup read from callisto.rc
1144 + MCalibCalcFromPast.fNumEventsDump
1145 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1146 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1147
1148 - callisto: MExtractTimeAndChargeSpline extractor:
1149 + The integration ranges were shifted by 0.2 FADC slices to the right.
1150 + unreliable handling of floating point values caused different
1151 results on different platform or with different compiler options:
1152 The new algorithm is numerically exact and more accurate because
1153 it doesn't calculate the integration position by multiple times
1154 adding the step-size (which results in numerical uncertanties
1155 exspecially if multiplied with large numbers)
1156 + A lot of fixes have been introduced which effects integrating the
1157 spline at the edges of the valid range. In this case any memory
1158 was randomly accessed. This behaviour can be tested replacing
1159 all MArrayF by TArrayF which perform a range check (but of course
1160 they are a lot slower)
1161 ! No result obtained with the Spline before can be trusted! Due to
1162 random memory access it might by completely random!
1163
1164 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1165 + extraction range in the high gain to 4.
1166 + weights file to cosmics_weights46.dat
1167
1168 - callisto:
1169 + introduce the check for fluctuating arrival times.
1170 + set charge limit to from 2.5 to 4.5
1171 + introduce asymmetric exclusion due to "deviating number of phes":
1172 Default: -9.0 +4.5
1173 + make deviating number of phes unsuitable (see David's findings).
1174
1175 - callisto: fixed the display of unsuitable pixels. The old change
1176 to a real profile in MHCamera broke it.
1177
1178 - callisto: The cosmics filter is used in MJCalibration now
1179 independant of the pulser color (formaly it was used only for
1180 CT1-pulser data). The threshold of number of max empty pixels
1181 has been raised from 2% to 5% in MJCalibration. The maximum
1182 fraction of rejected event is 50% otherwise the calibration has
1183 failed. The filter now ignores unsuitable pixels.
1184 Setup the filter from callisto.rc using "ContCosmics"
1185 (see MFCosmics::ReadEnv)
1186
1187 - callisto: changed default for fgOffsetFromLogain back
1188 from -2.8 to -1.8 in digital filter.
1189
1190 - callisto: for the common extractors
1191 + MExtractFixedWindow
1192 * MExtractTimeAndChargeSlidingWindow
1193 * MExtractTimeAndChargeSpline
1194 * MExtractTimeAndChargeDigitalFilter
1195 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1196 and fResolutionPerPheLoGain
1197
1198 - callisto: Updated the hi-/lo-gain intercalibration constants
1199 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1200 hilocalib_df6.root
1201
1202 - callisto: The default lo-gain extraction window for the
1203 MExtractTimeAndChargeSlidingWindow extractor has been increased
1204 from 6 to 8 to take the stretch of the pusle into account
1205
1206 - callisto (!!!): fixed an important bug in the setting of the
1207 incoming pedestal pointer to the signal extractor extracting
1208 pedestals. This bug caused the pedestals not to be subtracted
1209 correctly in the calibration afterwards. The effect was about 10%
1210 too high conversion factors for the digital filter and the spline
1211 and more than 40% for the sliding window.
1212 The bug existed since end of February! (Markus G.)
1213
1214 - star: added muon support to star. A new tab "MHMuonPar" is
1215 displayed. The lower right plot is an estimate of the point spread
1216 function. A reference value is displayed. To get the real PSF
1217 you must compare with MC. The setup for the muon analysis
1218 is done in star.rc. More informations can be found in
1219 MHSingleMuon and MHCalibParCalc
1220
1221 - star: The weather data is now displayed in star
1222
1223 - star: MEventRateCalc handles the calculation of the event rate more
1224 accurate now in case of the start of a new run inside a sequence
1225
1226 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1227 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1228 changed only minimally
1229
1230 - ganymed: (MJCut and MJOptimize) now displayes the number of
1231 excess events versus size. The energy estimation is done in
1232 MJSpectrum (sponde)
1233
1234 - ganymed: got support for using other variables than Alpha, eg. Theta.
1235 Therefor you need a class deriving from MHAlpha which supports
1236 this variable (one is already existing: MHTheta, which is now the
1237 default in ganymed). It is setup through ganymed.rc
1238
1239 - added a full featured spectrum program (sponde) which reads
1240 ganymed output and monte carlos and compiles a spectrum
1241
1242
1243
1244 *** Version 0.9.1 (2005/04/14)
1245
1246 - Fix bug on the arrival time reconstruction when using Digital
1247 Filter (in some marginal cases (10%) times were reconstructed shifted
1248 by 0.2 slices)
1249
1250 - all executables now return 2 where in previous versions -1 has
1251 been returned (gave problems with shell-scripts)
1252
1253 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1254 also done with a intercalibration input file
1255
1256 - a bug in the time fine adjustment of the digital filter has been fixed
1257
1258 - a lot of small fixes to calling TPad::Divide with a margin==0
1259
1260 - MStatusDisplay now shows the memory usage
1261
1262 - added a memory leak statistic after the eventloop
1263
1264 - MHadronness replaced by MParameterD
1265
1266 - MEnergyEst replaced by MParameterD
1267
1268 - wobble mode can now be switched on from the data-set
1269
1270 - switched on bad pixel detection for a pedestal level
1271 which is more than 5 times the variance
1272
1273 - Fixed default paths to be correct for the new data center
1274
1275 - Fixed handling of drive data. The pointing position in now
1276 copied to MPointingPos inside star for real and MC events
1277
1278 - made sure, that the sequences in a dataset are sorted by
1279 their number to ensure the correct synchronization
1280
1281 - added all resource files necessary to handle spline extraction
1282 of signal for the late 2004 and the early 2005 data
1283
1284 - update the reference lines for the december data
1285
1286 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1287 This is important for the Dec. and Jan. data where the calibration
1288 pulse position changes much.
1289
1290 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1291 filter. This corrects only an defective extraction of the MC at
1292 low-gain signals lower than 90 phes.
1293
1294 - fixed some slowdown in calibrating data with interleaved events from
1295 Jan and Dec. As a workaround made the pretty palette the default.
1296 The inverse Deep Blue Sea has a bug which slows down long calibration
1297 runs a lot.
1298
1299 - implemented new values from new starguider report as defined
1300 in TDAS00-07 V7.1 (eg SkyBrighness)
1301
1302 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1303 in starguider report (If you merpp the same reports with this version
1304 you'll get the correct units (arcmin) but a different result
1305 than with old versions (wrong units))
1306
1307 - Now the status display can also write PNG, JPEG and XPM (other file
1308 formats are still unsupported by root)
1309
1310 - added a lot of scripts and macros in directory datacenter used
1311 for automatic processing
1312
1313
1314
1315 *** Version 0.9 (2005/03/23)
1316
1317 - Calibration is now done autmatically into photo-electrons like
1318 decided by the Collaboration Board
1319
1320 - Reference lines in the display can be read from resource file
1321
1322 - Interlaced calibration events can be handled by callisto
1323
1324 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1325 and applied in callisto.
1326
1327 - class MJCalibTest can be called by callisto
1328
1329 - callisto can now run with three data types: rawdata, rootdata, MC
1330
1331 - added two classes mreport/MReportStarguider.cc and
1332 mreport/MReportStarguider.h for implementing starguider-data
1333
1334 - the output of merpp-update now contains starguider information:
1335 MReportStarguider and MTimeStarguider
1336
1337 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1338 values were lower than they should. This was more visible for high
1339 energy (Size) events.
1340
1341 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1342
1343 - added a new loop to callisto to support the correct extraction of
1344 the pedestal and pedestal rms through the signal extractor
1345
1346 - added class to perform fourier tranformation of a hexagonal structure
1347 (MHexagonalFT)
1348
1349 - added class to perform fourier tranformation of a hexagonal structure
1350 in a tasklist (MHexagonalFTCalc) example: hft.C
1351
1352 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1353 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1354 small pixels, example: extendcam.C
1355
1356 - added possibility to write data to memory (TTree) using MWriteRootFile
1357
1358 - added possibility to read a TTree stored only in memory by MReadTree
1359
1360 - new classes to deal with the interleaved calibration events:
1361 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1362
1363 - implemented filters to callisto to skip calibration events
1364
1365 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1366 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1367 the slices by statistics
1368 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1369 signal extractor without randomization
1370 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1371 with the signal extractor with randomization (extraction window is
1372 randomly fixed)
1373 The three kind of pedestal is not yet implemented (for speed reasons) as
1374 long as nobody really needs it:
1375 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1376 extracted with the signal extractor with randomization
1377
1378 - callisto now finds the pulse position in the data automatically
1379
1380 - implemented data reduction in calibrated data by reducing the precision
1381 of the stored floating point values (pedestal, rms and signal) to
1382 roughly 0.5%
1383
1384 - fixed showplot to make file format conversion (eg. converting a
1385 status display stored in a root file into a postscript file) in
1386 batch mode possible:
1387 showplot -b --save-as-ps[=outfile.ps] infile.root
1388
1389 - Allow class names as part of filter rules, eg
1390 (MFSupercuts) && (MHillas.fSize>100)
1391
1392 - fixed a lot of stuff to allow all programs to process MonteCarlo
1393 camera files.
1394
1395 - enhanced possibility to debug reading of resource file
1396
1397 - MDataChain should handle priorities of operator more
1398 accurate now
1399
1400 - completely revised the container in which the signal is stored
1401 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1402 * the new implementation is faster and
1403 * needs less storage space
1404
1405 - FIRST version which can process Monte Carlos through the
1406 whole chain of programs (callisto, star, etc)
1407
1408 - implemented new image parameters for the border length of
1409 the shower image (MNewImagePar2)
1410
1411 - implemented wobble-mode in ganymed
1412
1413 - new class (MJOptimize) taking care of all optimization processes
1414
1415
1416
1417 *** Version 0.8.6 (2004/10/05)
1418
1419 - New combined signal and time extractor
1420 MExtractTimeAndChargeDigitalFilter
1421
1422 - The Report for the trigger section in the CC run summary has been
1423 updated, and now the IPRs (Individual Pixel Rates) are available.
1424
1425 - new macros for database interaction: filldotrun.C, filldotrbk.C
1426
1427 - added new program which can convert colored output which was redirected
1428 into a file back into colored text (for example to display it with
1429 more): showlog
1430
1431 - added new program to display an MStatusArray of plots (stored with
1432 MStatusDisplay) from a file: showplot
1433
1434 - Added support for Sequences (MSequence). Sequences are blocks of run
1435 files containing the same calibration and belonging to the same
1436 source
1437
1438 - Added a new task (MTaskEnv) which can be used in setup files to switch
1439 between different tasks (for example to choose a signal extractor)
1440
1441 - Implemented automatic file splitting in MWriteRootFile
1442
1443 - After image cleaning an island index is assigned to all used pixels.
1444 The index corresponds to the order of the islands in size.
1445
1446 - added a cleaning which takes signal height _and_ arrival time into
1447 account: probability cleaning (for more details see MImgCleanStd)
1448
1449 - added a cleaning which takes takes the absolute number of photons
1450 times the area ratio as cleaning level
1451 (for more details see MImgCleanStd)
1452
1453 - Changed calculation of image parameters such, that it can be done
1454 for all used pixels or the pixels with a defined island index only
1455
1456 - implemented new image parameters displaying the number of islands,
1457 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1458
1459 - event display in executable changed to support also calibrated files
1460 (done with MJCalibrateSignal)
1461
1462 - added program doing the calibration and the signal extraction
1463 and signal calibration: callisto Most part of the setup is done
1464 by a resource file: callisto.rc
1465
1466 - implemented support for pixels with negative IDs (Raw file format
1467 version 4)
1468
1469 - implemented an new option in merpp (--auto-time) to get the time
1470 range for cc and/or caco data from the run header of the raw data
1471
1472 - New star-program (star and MJStar). Taking calibrated data from
1473 callisto/MJCalibrateSignal as input. The setup is done through
1474 a resource file: star.rc
1475
1476 - Added possibility to setup the eventloop in the mars-executable
1477 Camera Display by a resource file: mars.rc
1478
1479 - The the mars-executable Camera Display can now also read
1480 calibrated data files written by callisto/MJCalibrateSignal
1481
1482 - Added a new class which can calculate the source position in
1483 the camera from a pointing model known to be correct and
1484 the pointing model used for observations (MSrcPosFromModel)
1485
1486 - added a new version of the class calculating the effective on-time
1487 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1488 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1489 MHTimeDiffTheta.
1490
1491 - added the possibility to count how often a signal is above (or
1492 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1493 can replace MHTriggerLvl0)
1494
1495 - added ore convinient ways to set the axis-titles of your histograms
1496 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1497 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1498
1499
1500
1501 *** Version 0.8.5 (2004/08/06)
1502
1503 - new Signal Extractors: MExtractFixedWindowSpline
1504 and MExtractAmplitudeSpline
1505
1506 - implementes interleave in merpp to be able to merpp parts of a file
1507
1508 - implemented force-functionality to merpp
1509
1510 - star display to display star catalogs (MAstroCatalog)
1511
1512 - star display to 'mirror' stars to the camera (MAstroCamera)
1513
1514 - implemented a new cleaning option which allows cleaning scaled with
1515 the real ratio of the rms depending on the pixel size, not only the
1516 square root of the pixelsize (MImgCleanStd, MCameraData)
1517
1518 - removed obsolete MBlind* classes
1519
1520 - Signal extractor taking the AB flag into account implemented (this makes
1521 an odd number of slices for signal extraction possible
1522 (MExtractSignalABcorr)
1523
1524 - implemented a class extracting the pedestal from the raw-data (events)
1525 itself using empty lo-gain (MpedCalcFromLoGain)
1526
1527 - Added mean values to MPedPhotCam
1528
1529 - Added Makefile for Darwin (this OS is NOT officially supported!)
1530
1531
1532
1533 *** Version 0.8.4 (2004/04/19)
1534
1535 - new fast arrival time extractor using cubic splines:
1536 MExtractTimeFastSpline
1537
1538 - implementes multi-argument support in MDataChain
1539 ("pow(a, b)")
1540
1541 - implemented double reference support in MDataChain
1542 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1543
1544 - added support in MF for expressiond like
1545 "MHillas.fWidth<2*<MHillas.fLength"
1546
1547 - MDataChain is now able to support variables like [0], [1], ...
1548 which can be used in fit functions as parameters. The interface
1549 is implemented through the new virtual function
1550 MParContainer::SetVariables
1551
1552 - added new class MArrivalTimeCam/MArrivalTimePix:
1553 Storage containers to hold the ArrivalTime of the camera/pixel
1554
1555 - added new classes for the calibration of relative arrival times:
1556 MCalibrationRelTimePix and MCalibrationRelTimeCam
1557
1558 - added new classes to extract the signal of the blind pixel and the
1559 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1560
1561 - added new classes for the bad-pixels treatment (MBadPixels*)
1562 which are more powerfull than the old ones (MBlindPixel*)
1563 and will replace them.
1564
1565 - added filter against cosmics: MFCosmics
1566
1567 - added new class MArrivalTimeCalc2:
1568 Calculates the arrival time as the signal weighted mean of the time
1569 slices in the maximum window
1570
1571 - added a new macro call pointspreadfucntion.C that fits with a 2D
1572 gaussian the DC spot for an star. It gives you the RMS of
1573 the PSF and the center of the star, very useful for misspointing
1574 studies.
1575
1576 - added support for multi-telescope camera files. Added classes
1577 MStereoCalc and MStereoPar, classes to calculate and store shower
1578 parameters calculated from the data of two telescopes, for the MC
1579 studies regarding the MAGIC clone.
1580
1581 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1582 MC data calibrated in photons instead of ADC counts.
1583
1584 - added three macros to show the calibration and analysis chain of
1585 MC data. The macro starmc.C does both calibration and analysis, producing
1586 an output containing Hillas parameters for each event. The macro
1587 mccalibrate.C does just the calibration and writes out a file containing
1588 pixel information in photons instead of FADC data. The macro starmc2.C
1589 reads in such a file and produces an output with Hillas parameters.
1590
1591 - added MPedPhotCalc to compute pedestals in units of photons, see
1592 macro pedphotcalc.C
1593
1594 - added all class to perform the calibration, see macro calibration.C
1595
1596 - added class MFFT to perform Fast Fourier Transforms
1597
1598 - added class MSimulatedAnnealing to perform simulated annealing
1599 minimizations
1600
1601 - added new macro bootcampstandardanalysis.C which holds the skeleton
1602 of the analysis chain discussed in the december bootcamp.
1603
1604 - added support for DAQ raw data file format V2
1605
1606 - implemented an arbitrary time stamp for the events from raw-data
1607 files with file version<3. It is calculated from the run number,
1608 the date of start and the FADC clock tick from the first module
1609
1610 - implemented the correct decoding of the event time-stamp
1611 coming from the DAQ for raw-data files with file-version>2
1612
1613 - added a new classes storing the pedestals in units of photons:
1614 MPedPhotPix, MPedPhotCam
1615
1616 - added support for DC current files from the camera control
1617
1618 - added support for start- and stop-time when merpping report files
1619
1620 - added MReportCC storing the weather data from the CC-REPORT
1621
1622 - added class to fill trainings and test matrices (MTFillMatrix)
1623
1624 - added a filter performing a software trigger (MFSoftwareTrigger)
1625
1626 - Added classes to perform parts of the standard analysis (Jobs):
1627 + MJPedestals
1628 + MJCalibration
1629 + MJExtractSignal
1630 Note: All of them are preliminary!
1631
1632 - Added Iterator to iterate over files giving only the run-number
1633
1634 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1635 the evolution of a sector vs time
1636
1637
1638
1639 *** Version 0.8.3 (2003/12/05)
1640
1641 - adapted Random Forest classes to allow the use with MC
1642 multi-telescope files which can be produced with the coming
1643 camera version 0.7.
1644
1645 - added classes to read and interprete central control report files
1646 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1647
1648 - enhanced merpp (the executable) to support .raw and .rep files.
1649
1650 - added classes for light calibration (MCalibration* and
1651 MHCalibration*) by Markus Gaug. Further work has to be and will
1652 be done soon.
1653
1654 - Added a preliminary 'synchronizer' (MReadReports) which will
1655 replace MReadMarsFile as soon as it is finished.
1656
1657 - Added a tutorial macro demonstrating how report files are merpped
1658 and how they can be read from the root file in the correct order
1659 of time (readrep.C)
1660
1661 - Added a generalized histogram (similar to MH3) called MVsTime
1662 which allows to plot variables (or rules - MDataChain - of
1663 variables) vs time. For an example have a look at tempvstime.C.
1664
1665 - Changed the name of the event trees:
1666 + Events --> Events
1667 + PedEvents --> Pedestals
1668 + CalEvents --> Calibration
1669
1670 - changed name of MTime in the event trees from MRawEvtTime to MTime
1671
1672 - added displaying the sector indices to the mars event display
1673
1674 - Magic Online Analysis (MOnA) implemented in a first version
1675 (see mona.cc, MOnlineDump and MOnlineDisplay)
1676
1677 - added classes to calculate event rate
1678 (preliminary: MEventRateCalc, MEventRate)
1679
1680 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1681
1682 - added classes dealing with the telescope pointing position (MPointing*)
1683
1684 - implemented the 'final' Mars time stamp based on some experiences with
1685 the new 'Synchonizer'
1686
1687
1688
1689 *** Version 0.8.2 (2003/11/10)
1690
1691 - accelerated standard analysis by a factor of 6-8 ...
1692 + doing precalculations in MGeomCam for the pixel area ratio
1693 + creating a look up table for the single pixels in MCerPhotEvt
1694
1695 - added task to calculates weights in case you want to 'change'
1696 the energy spectrum of a monte carlo file
1697 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1698
1699 - added a new executable star which implements the
1700 star.C macro as precompiled executable. Currently a flexible
1701 setup is not possible, but a 'input card' setup will follow.
1702
1703 - Starting to implement Multi-Telescope-Support based on the
1704 upcomming camera version 0.7. The base for a general support
1705 is implemented and the star-functionality is proven to work.
1706
1707 - Replaced Event-Display in and Camera-Display in the Mars GUI
1708 executable by a more convinient display base on MStatusDisplay.
1709
1710 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1711
1712
1713
1714 *** Version 0.8.1 (2003/10/20)
1715
1716 - added signal subtraction for pure on data by means of fitting
1717 the background in the off region or by performing a combined
1718 signal/background fit. Provides necessary histograms for
1719 obtaining energy spectra and a light curve.
1720
1721 - added classes to perform and study the selection of the
1722 2nd Level Trigger on MC data (example in triglvl2.C macro)
1723
1724 - added pedestal calculation
1725
1726 - implemented "democratic cleaning" (tail cut value proportional
1727 to pixel area) according to Wolfgang's suggestion.
1728
1729 - added Sigmabar treatment (calculation and basic histogramming)
1730
1731 - added basic routines to apply padding
1732
1733 - added first implementation of MARS-based source visibility plotter
1734 (needs to be linked against slalib, preliminary version)
1735
1736 - enhanced functionality of data chains: random numbers, conversion
1737 functions and access to MHMatrix objects
1738
1739 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1740 numbers under certain circumstances (runs with 0 events included)
1741
1742 - fixed a bug in the general filter MF (didn't work on some systems
1743 at all)
1744
1745 - fixed a bug in chaining files, which caused the analysis to crash or
1746 ignore files
1747
1748 - implemented more geometry classes describing the parameters used
1749 to simulate the PMT camera
1750
1751 - added new Monte Carlo classes containing the setup of the different
1752 programs in the MC chain.
1753
1754 - added a (preliminary) general task to evaluate chi-square of a given
1755 parameter in an eventloop.
1756
1757 - first implementation of a container describing the observatory
1758 location (Long, Lat, etc)
1759
1760 - added Random Forest - method for g/h-separation
1761
1762 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1763 (this means, that it is compiling, but not yet fully tested)
1764
1765 - added a new status display which can show the present status
1766 of histograms while an eventloop is running (MStatusDisplay,
1767 an example can be found at status.C)
1768
1769 - reorganized directories:
1770 classes describing the image --> mimage
1771 classes containing Monte Carlo Histograms --> mhistmc
1772 classes for Random Forest method --> mranforest
1773
1774 - added (event-)weights to fill histograms
1775
1776 - colors in logging output to screen
1777
1778 - changes to the Image Parameter declaration:
1779 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1780 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1781 + MHillasExt now derives from MParContainer instead of MHillas
1782 --> Files written with the old definition are more or less unreadable
1783
1784 - reading of reflector files
1785
1786 - display data from reflector files in the camera
1787
1788 - implemented currents (and display them in the camera)
1789
1790 - logarithmic scale in camera
1791
1792 - added class to iterate through directory contents (MDirIter)
1793
1794
1795
1796 *** Version 0.8 (2002/11/18)
1797
1798 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1799
1800 - corrected 48(!) wrong entries in the Next Neighbor table of the
1801 Magic Camera (all in the inner part of the outer ring, mostly
1802 missing a single NN)
1803
1804 - Fixed a bug in the table describing the Next Neighbours of the
1805 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1806 have any neighbour)
1807
1808 - changed trigrate.C: now it calculates the pure NSB triggers from
1809 a camera file (generated with no showers), so there is no need
1810 to introduce them by hand in the BgR array (for more details
1811 please ask Abelardo)
1812
1813 - added MHHadronness (and MHadronness) as a general facility to evaluate
1814 the quality of a gamma-hadron seperation method
1815
1816 - changed MWriteAsciiFile to accept rules (MDataChain)
1817
1818 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1819 must be replaced by calles to MWriteAsciiFile::AddColumn and
1820 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1821 changed.
1822
1823 - Implemented generalized event-matrices (one row per event)
1824 (MHMatrix)
1825
1826 - implemented the one dimensional composite probabilities
1827 (MHCompProb, MCompProbCalc, comprob.C)
1828
1829 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1830 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1831
1832 - Added a camera display displaying the pixel numbers to the
1833 event display gui.
1834
1835 - Added Monte Carlo Informations to event display gui
1836
1837 - Changed the camera display to display the pixel numbering
1838
1839 - Added three buttons to the camera display to change the palette
1840
1841 - Added the number of used and core pixels after image cleaning
1842 to MHillas
1843
1844 - Changed the algorithm used in MHillas according to TDAS 02-03
1845
1846 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1847
1848 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1849
1850 - Added fCosDeltaAlpha to MHillasSrc
1851
1852 - The numbers of photons used to calculate fConc and fConc1 in
1853 MHillasExt are now scaled with the pixel size, so that one get
1854 a four times smaller value for the bigger pixels in the outer ring.
1855
1856 - added new task to smooth the camera contents (MCameraSmooth)
1857
1858 - added possibility to use interpolated pixel values for blind pixels
1859 instead of removing it completely from the analysis
1860
1861 - Implemented the possibility to save the whole eventloop with
1862 its setup to a file. This information can be read and from
1863 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1864 and MEvtLoop::MakeMacro. If you find something not working, please
1865 report - this stuff is still in a beta phase.
1866
1867 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1868 file having crab starfield, but also for all following files - fixed
1869
1870 - MTaskList::PrintStatistics can now be instructud to print also the
1871 title, too: use PrintStatistics(0, kTRUE)
1872
1873 - Changed the image cleaning so that pixels with to many 'used'
1874 neighbors are left used (to get rid of 'holes' in events)
1875
1876 - Introduced more output to the camera displays
1877
1878 - Added an array of histograms (eg one hist per run), MHArray
1879
1880 - Added a _preliminary_ version of the reader for CT1 PreProc files
1881 (MCT1ReadPreProc)
1882
1883 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1884 (thanks to Raquel)
1885
1886 - added the first energy estimator (MEnergyEstParam, estimate.C,
1887 estfit.C) using a parametrization
1888
1889 - Added some new Monte Carlo paremeter containers used to store
1890 setup information from the MC chain (MMcConfigRunHeader,
1891 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1892
1893
1894
1895 *** Version 0.7 (2002/04/30)
1896
1897 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1898 the pedestal mean value was saved incorrectly. For files from
1899 this versions we substract 0.5 from the pedestal mean.
1900 WARNING: This may effect your results, so don't wonder...
1901
1902 - First implementation of an algorithm using only triggered events
1903 for the collection area calculation
1904
1905 - Ascii Output can now also be used for parameter containers which
1906 doesn't overload MParCointainer::AsciiWrite
1907
1908 - The Ascii Output is now also capable of writing single data members
1909 of one container
1910
1911 - You are now able to change the order of the values written to the
1912 ascii file
1913
1914 - You can now specify a conversion factor for each data member written
1915 to an ascii file. This may be usefull to change the units of the
1916 data member (eg. degrees instead of millimeters in case of the
1917 hillas parameters)
1918
1919 - Replaced old MHillas by a new structure which allows you to extend
1920 the parameters stored in MHillas very easily:
1921 see MHillas and MHillasExt
1922
1923 - Added classes to handle source dependancy of image parameters:
1924 see MHillasSrc
1925
1926 - Added container (MBinning) to have a standard input for the binning
1927 in different histograms (eg. the Energy bins should be the same in
1928 all histograms)
1929
1930 - Changed Hillas histograms from mm to deg
1931
1932 - Added the flexible binning to the hillas histograms
1933
1934 - Added a filter for the alpha parameter (MFAlpha)
1935
1936 - It is now possible to write single data members of a class object to
1937 an output stream instead of the whole container only
1938
1939 - Added a generalized filter for a data member:
1940 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1941
1942 - Added a generalized Filter parser for more difficult filter rules
1943 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1944
1945 - Added new Monte Carlo histograms:
1946 MHMcEnergyImpact and MHMcEfficiency
1947
1948 - Added many new histograms needed for the flux calculation.
1949
1950 - Added a generalized histograms which can fill and show up to three
1951 data members in either a one-, two- or three-dimensional histogram, eg:
1952 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1953
1954 - Added:
1955 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1956 * calculation of <Theta> as a function of time (MHThetabarTime)
1957 they are needed in the flux calculation in
1958 order to select for a given bin in Theta (or time) the appropriate
1959 effective collection area, which is assumed to be given as a function
1960 of Theta and the true energy
1961
1962 - Added calculation of the migration matrix in the energy
1963 (MHMcEnergyMigration):
1964 the migration matrix describes the migration from the true (E_true)
1965 to the estimated energy (E_est); it is needed to determine the
1966 distribution of E_true from the measured distribution of E_est
1967 by unfolding
1968
1969 - changed the color palette in the camera display to DeapSea.
1970
1971
1972
1973 *** Version 0.6 (2002/01/15)
1974
1975 - Introduce the option of disable pixels (MBlindPixels and
1976 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1977 able to deal with Star Field NSB.
1978
1979 - Fixed a bug in the pedestals substraction
1980
1981 - Introduced verbosity levels
1982
1983 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1984
1985 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1986 work correctly (thanks to Abelardo)
1987
1988 - Introduced correct treatment of the diffuse Night Sky Background
1989 and NSB (MMcPedestalNSB)
1990
1991 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1992
1993 - Introduced MMcRunHeaders which contains monte carlo run informations
1994
1995 - Added a 'Print'-Task (MPrint) which calls the Print function
1996 of a parameter container for each event
1997
1998 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1999
2000 - changes to be more efficient with root 3.02/06
2001
2002 - root 3.02/06 fixes:
2003 + the memory leak when reading MRawEvtData
2004 + loosing more time than necessary to update the progress bar
2005
2006 - MWriteAsciiFile is now capable of writing more than one container
2007 in a line. For example: To be able to write Monte Carlo and
2008 Hillas values (energy and alpha) in one line.
2009
2010
2011
2012 *** Version 0.5 (2001/11/06)
2013
2014 - Added new GUI functionality (Analysis)
2015
2016 - Added a camera display to be able to display events in the camera
2017 together with the calculated hillas ellipse
2018
2019 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2020 object at any state of the analysis, so that the output are several
2021 states
2022
2023 - Fixed a bug in the collection area error calculation
2024 (Thanks to Ciro and Abelardo)
2025
2026 - Fixed a bug which causes merpp to crash in some environments
2027
2028 - Implemented auto enabling scheme for Branches to speed up reading
2029 a lot (see MReadTree and MTask)
2030
2031 - Fixed a bug in the Histogram classes which caused histograms to
2032 be written to a file by MWriteRootFile without request
2033
2034 - changed the object I/O from the old stylish root I/O to the new
2035 'auto evolution scheme' This was done only for classes which are not
2036 yet used in Monte Carlo files, so that these files are still readable.
2037
2038 - Added support for a progress bar in MEvtLoop and MReadTree
2039 (see the Analysis Window in Mars for an example)
2040
2041 - Fixed a bug in the package creation which disturbed the conversion
2042 between a mars version unpacked from a tar file and the repository.
2043
2044 - Changed the code to writer merpped (converted into root format)
2045 raw files, to get faster (around 10%)
2046
2047
2048
2049 *** Version 0.4 (2001/09/20)
2050
2051 - This release is made to compile on a root version >= 3.00
2052
2053 - Fixed a bug which causes MReadTree to read the first file only
2054
2055 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2056
2057 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2058
2059 - Added a task to write several container to a root file (MWriteRootFile)
2060
2061 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2062
2063 - Added calculation of the collection area (MMcCollectionAreaCalc)
2064
2065 - fixed some bugs in the Hillas calculation
2066
2067 - added filters to be able to control the task execution dependent on
2068 a parameter (for example: the number of level 1 triggers in a MC-file)
2069
2070
2071
2072 *** Version 0.3 (2001/04/23)
2073
2074 - Many demo macros added
2075
2076 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2077
2078 - Hillas Calculation added
2079
2080 - Standard image cleaning available
2081
2082 - MReadTree is now able to handle more than one file
2083 (Remark: of the same structure)
2084
2085 - Now we are able to display events in a first version of the
2086 Camera event display. To do this we must run the macro
2087 "macros/readCT1.C" to read data from CT1.
2088
2089
2090
2091 *** Version 0.2 (2001/01/24)
2092
2093 - First Implementation of a Gui to read the raw data. Start the
2094 gui with the command mars.
2095
2096
2097
2098 *** Version 0.1 (2000/12/20)
2099
2100 - First official release 0.1
2101
2102 - Changes:
2103
2104 + changed calling style of MRawPixelIterator from do...while to
2105 while-loop
Note: See TracBrowser for help on using the repository browser.