source: trunk/MagicSoft/Mars/NEWS@ 9178

Last change on this file since 9178 was 9178, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 125.6 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * This release doesn't contain a major changed which is expected to
8 change your result. Nevertheless there are small changes to
9 the calibration which can effect at least the first few hundred
10 events in any (mainly MUX and even more SUM) sequence a little bit.
11 So it is recommended although not necessary to reset your sequences
12 in the database before further processing.
13
14 ;general
15
16 * All command line options after -- are now interpreted as
17 arguments (usually everything which doesn't start with a minus)
18 rather than options (usually everything which starts with a
19 minus). This allows to use file names starting with a -
20
21 ;Database
22
23 * Added informations about the DC currents (fMinCurrents, fMedCurrents
24 and fMaxCurrents). The values are retrieved from the plots showing
25 the average DC currents of all pixels versus time.
26
27 * Websites with tables have now the opportunity to remove lines
28 ('-' button at beginning of each line) and get all lines back
29 ('+' at top of the column)
30
31 * Websites: added option to query only sequences containing sumtrigger
32 events
33
34 ;automatic analyis
35
36 * Rewritten producing plots in the web.
37 New plots, namely the output of plotoptical.C (extinction curve from
38 KVA), plotstat.C (status of the automatic analysis (percentage of
39 processed, analysed data etc.)) and plotusage.C (statistics of the
40 condor usage in the data center) has been are available now next to the
41 plots of plotdb.C
42 Mean values from the plots (output of the macro) are provided in a
43 txt file now.
44 The creation of the plots for callisto, star and ganymed in the web is
45 now steered via database. Consequently the plots are faster and
46 reliable up-to-date.
47 For all plots, a new layout is available facilitating the browsing
48 through the plots and providing additional information on the
49 displayed values. (tabs.php) These plots are linked from the DB
50 websites and the wiki.
51
52 ;merpp
53
54 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
55 instead of RunHeaders)
56
57 * Now allows to merpp files newer than 2008/09/03.
58
59 ;callisto
60
61 * Extracting the pulse position for the pulse position check events
62 with sum trigger were denied. This decreased the statistics
63 extremely and therefor the resulting puse position was calculated
64 quite weak. Now sum events pass the calculation if and only if they
65 have also a level 1 trigger.
66
67 * the extraction of pedestal events and pulse position from the
68 first data events is now more automatic and makes sure that
69 a more precise number of events is extracted independent of
70 the ratio with which pedestal events or events with signals
71 are contained in the data.
72
73 ;star
74
75 * For the calculation of the effective on time all sum-triggered events
76 were skipped. Now all Level1-triggeres events will pass. This might
77 result in a slight inaccuracy of the effective on time.
78
79 ;ganymed
80
81 * If the source position is more than 1deg away from the camera
82 center an error is raised now.
83
84
85
86== Version 2.1.1 (2008/08/04) ==
87
88 ;Database
89
90 * Added the median number of photo electrons from the calibration
91 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
92 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
93
94 * Added fTotOnTime, which is the on-time as given by the run-headers
95 (in contradiction to fAbsOnTime which comes from CC)
96
97 * Added new primaries for the new data structure (Magic II): for the
98 tables dealing with sequences (SequenceBuild Status, Sequences,
99 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
100 this is the telescope number (fTelescopeNumber) for the tables dealing
101 with runs (RunData and RunProcessStatus) this is in addition the file
102 number (fFileNumber)
103
104 * Added column fPriority to the status tables to be able to steer the order
105 in which the data is processed. As default the run, sequence and dataset
106 number are used.
107
108 ;automatic analyis
109
110 * Adapted scripts to the new data structure: They can handle now different
111 telescopes (getting the information as usual from the database).
112 The paths for Magic 2 are not yet implemented.
113
114 ;general
115
116 * should work now with root 5.20/00 (please note that root 5.20/00
117 we encounter crahses in the status display which are ot yet
118 understood)
119
120 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
121 instead of the base name of the file. This makes them easier to
122 access from the code
123
124 * Default Monte Carlo names in MSequence do not require the _E at
125 the end anymore
126
127 * where abrrevating a sequence file with a sequence number is possible
128 also "telescope:sequence" is now accepted, e.g.:
129 star 2:2000123 --out=output
130 see the programs' help for more details.
131
132 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
133 from the database. See the constructors for more details.
134
135 * MReadTree now supports friends
136
137 * MReadTree can now read also files not written by MARS and store
138 the data encapsulated in emulated MParContainers
139
140 * added a new starguider calibration valid since 15.1.08
141
142 ;showplot
143
144 * showplot can now read more than one file at once. This is especially
145 inetersting if reading files containing pure canvases
146
147 ;merpp
148
149 * we merpp the dc currents now also from the camera reports (they have
150 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
151
152 * In the automatic analysis we omit merpping of the currents from the
153 caco files and use the lower rate camera reports from the cc files
154 instead
155
156 * merpp has been redisigned to allow merpping of the cc-reports
157 of a whole sequence. This allows to design a very simple analysis:
158 mkdir output
159 ./callisto 100776 --out=output
160 ./merpp 100776 output
161 ./star 100776 --ind=output --out=output
162 Instead of the sequence number also sequence files are accepted.
163
164 * Implemented a fix for run-numbers between 1001348 and 1001396
165 which were incorrectly assigned by the cc.
166
167
168 ;callisto
169
170 * added a filter again which was was removed in the last release.
171 it removed the most brightest events. This should not change
172 any analysis result because these events are so bright that
173 they cannot be analysed anyway, but the bad-pixel plots doesn't
174 show outliers.
175
176 * updated muon calibration constants for the periods 51-57,
177 58-63 and 67-
178
179 ;star
180
181 * The camera currents are now displayed with the rate of the camera
182 reports instead of the caco reports
183
184 ;ganymed
185
186 * if mc camera files are new enough (>=8) the source position in the
187 camera is now calculated from the stored telscope and shower
188 orientation (Note, that this might not be suitable in all cases
189 depending on the aim of the study. These case still needs
190 implementation)
191
192
193
194== Version 2.1 (2008/06/18) ==
195
196 ;Database
197
198 * introduced average temperature and wind speed from star-files
199
200 * introduced average values from Pyrometer (mainly Cloudiness)
201
202 * introduced the ratio of accepted calibration events in the
203 calibration run
204
205 * introduced the average rates of the different trigger pattern,
206 e.g. the rate of pedestal and calibration events, from the signal-file
207
208 ;general
209
210 * fixed GroupBy options in plot*.C macros
211
212 * only display KVA points (not the Tuorla points) in plotoptical.C
213
214 * all programs now allow to add resources to the ones from the resource
215 file or overwrite them from the command line. This can be done like this
216 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
217 if something seems to be wrong you can debug what the program is doing
218 using the option --debug-env=3
219
220 * increased the diversity of debug levels. That also means that with -v3
221 you get now less output, i.e. only the output which is important for
222 an analysis. To get more output which helps for debugging try 4, 5 and 6.
223
224 * fixed a problem in the task synchronizing the reading of the reports
225 and the data stream. The effect was that in some circumstances the last
226 events of some trees could have been skipped. Since this is only a
227 very tiny part of the data no severe effect to your analysis results
228 is expected (an exception might be very short, i.e. singel runs,
229 datasets).
230
231 * Dataset file now allow to include the sequence file directly within
232 the dataset file and also allow to exclude single runs from the dataset.
233 (for more details see Class reference of MDataSet)
234
235 * Sequence files now allow for excluding runs from the analysis
236 (for more details see Class reference of MSequence)
237
238 * added code to process the sum-trigger flag
239
240 * the histogram classes MH3 and MHn now support profile histograms
241
242 * the histogram classes MH3 and MHn now support labels at the axis
243
244 * the Random Forest Train-classes (MJTRain*) now store the used datasets
245 in the output file
246
247 * the MFMagicCuts have a new option to allow a linear area cut (for
248 special studies)
249
250 * The liniking of the shared object is now done into a file defined
251 by 'mktemp'. This should be a local file system which accelerates
252 liniking a lot.
253
254 * The code has been prepared for compilation with root 5.18/00d
255
256 * The MHEnergyEst histogram now shows the distribution of
257 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
258 and (Eest-Emc)/Emc vs Emc.
259
260 * fixed mars (event display) for merpped raw-data and MC data
261
262 * adapted the synatx of sequence files to allow for the new run/file
263 scheme. For more details see class description of MSequence
264
265 ;showplot
266
267 * Added support for tiff files
268
269 * Added support for csv files (tables containing tab number,
270 name and title)
271
272 * Tabs now can have a title which is displayed in the postscript file
273
274 * When multiple file are written at once (e.g. pngs from a display)
275 it is now possible to use the tab name and or tab number in the
276 file name. For details see showplos's help.
277
278 ;merpp
279
280 * Implemented cc file version 2008-02-20/0
281
282 * Implemented cc file version 2008-05-19/0
283
284 * With new options merpping can be restricted (in addition to the
285 run-number) also by telescope and file number.
286 For details see "merpp --help"
287
288 * Implemented raw data format 11 (the most important change, except
289 from plenty of changes in the format definition, is the addition
290 of the file-number in the header) If nobody makes a mistake this
291 format should have the advantage that it is by definition forward
292 compatible, so old programs will be able to read newer formats.
293
294 * Added Pyrometer information to default output (stored in a new Tree
295 Pyrometer, needs a complete new merpp, i.e. new calibration)
296
297 * Merpping (also update) can now be restricted to one single report.
298 For example:
299 If you want to update an old file with Pyrometer information call
300 merpp --only=Pyrometer --update
301
302 ;callisto
303
304 * in the pedestal processing now at least 50 processed events are
305 required for succeeding.
306
307 * the signal and calib files now contain also the sequence information
308
309 * the two MPedestalCam in the calib file now have proper names
310 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
311
312 * Both pedestal cams now contain the number of events processed
313
314 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
315 i.e. for the extraction of the calibration pulses basically the average
316 over all events of the first slice instead of all slices was used.
317 Since pedestal and calibration constants are continously recalculated
318 this only effected the very first events of every sequence.
319
320 * For the extraction of the position of the maximum sample now the
321 extraction range is set automatically to the extraction window,
322 before the whole accessible range was used.
323
324 * If the number of samples in the events and the number of samples
325 in the run-header disagrees now an error is raised (this can
326 happen in not well simulated Monte Carlo files)
327
328 * In the case of MUX-data pedestal events with the lvl1 trigger flag
329 could survive into the pedestal calculation -- fixed.
330
331 * Tab "TrigPat" added showing the distribution of the trigger pattern
332 as found in the run-files (normalized with the run length)
333
334 * The selection of events from the trigger pattern has been improved.
335 If the trigger pattern is corrupted events won't pass anymore.
336
337 * Added a new command line option --dev-null to suppress output of
338 Y-files (this is useful for test cases)
339
340 * added a new tab "CalPos" showing the arrival time of extracted
341 interleaved calibration events
342
343 ;star
344
345 * the star file now contains also the sequence information
346
347 * Added a new command line option --dev-null to suppress output of
348 I-files (this is useful for test cases)
349
350 * Tab "Rate" added showing the distribution of the trigger pattern
351 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
352 the Y-files (normalized with the run length)
353
354 * The effective on-time calculation doesn't use events with only
355 sum-trigger anymore
356
357 * The data in the MHWeather tab has been reorganized. The never
358 working solar radiation has been removed and the data from
359 the pyrometer (cloudiness, air and sky temperature) is
360 displayed in addition.
361
362 ;ganymed/sponde
363
364 * Now data points are even shown correctly if they have error bars larger
365 than one sigma. Points with null or negative significances are omitted.
366
367 * DrawNicePlot now allows to set a projection range
368
369 * Updates pointing models. One is applied after the implementation
370 of the new LUTS in August, the other one is applied after the
371 next major change of the pointing model in October. Note that
372 these models are preliminary and give wrong results below Zd=65deg
373
374 ;sponde
375
376 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
377
378 * a new option "--force-runtime" is available. In case of very short
379 datasets (for light-curves) which are in the order of a few
380 minutes the calculated effective on-time is not very acurate because
381 it is quantizised in the order of a minute. Therefore you can switch
382 to using the real run-time instead (remakrt: this ignores any
383 dead-time!)
384
385 * a more analytical way is used to "fill" Monte Carlos into regions
386 of impact parameters which have not been simulated because the
387 trigger efficiency is assumed to be 0.
388
389 * estimated sensitivity curves for hi and lo zenith angles are shown
390 scaled to the correct observation time and collection area
391
392 * the Monte Carlo events after cuts are now written to the output file
393 if an output file given
394
395
396
397 *** Version 2.0 (2007/09/03)
398
399 - database: the position used for the pulse pos check was missing
400 in the callisto output and could thus not be filled into the DB.
401 Also the old values seemed not exactly the PulsePos used for
402 teh check.
403
404 - general: Resource file now allow an Include-Resource, i.e. you can
405 read a resource file with default settings, include it in your
406 resource file and overwrite the settings in your file. More than
407 one include file is allowed. Inclusions can be iterative.
408 Include: mydefaults.rc yourdefaults.rc
409 The resources in the first file have higher priority than the
410 second file.
411
412 - general: Now the output files (calib*.root, etc) also contain the
413 resource file (to check it open it in the TBrowser and choose Print()
414 from the context menu)
415
416 - general: Dataset files now allow to overwrite the default path
417 to search for sequence and data files. Note, that the program
418 option and individual resources will overwrite it. For example:
419 SequencePath: /magic/montecarlo/sequences
420 DataPath: /magic/montecarlo/star
421
422 - general: Fixed a problem with variables in MDataPhrase. It seems
423 that only optimdisp (didn't work) was effected.
424
425 - general: Some improvements to the optim and train processing. For
426 example the ststud window now got a proper title.
427
428 - general: The "Status Display: " was removed from the window title
429 within an Eventloop.
430
431 - general: added a new flexible histogram-class (MHn) which can be used
432 for example in testing after optimizations or training to produce
433 user defined histograms.
434
435 - general: The Random Forest now allows attaching an evaluation
436 function which is applied to its output. This allows to train
437 on whatever you like (eg. train on log10(energy), but return
438 energy)
439
440 - general: The Random Forest training of energy (trainenergy.c) and
441 disp (traindisp.C) has been improved by more graphical output to
442 judge the result.
443
444 - general: The training of energy (trainenergy.C) has been improved
445 a lot by training on a different quantity than energy. It gives
446 a result which is highly independant of the source spectrum
447 and shows lower bias than all other options.
448
449 - general: Dataset files are allowed to contain collections of
450 datasets. For more details see the class reference of MDataSet.
451
452 - general: The default WobbleMode in a datset file now (if not
453 overwritten) is "auto", i.e. wobble mode is set if the dataset
454 doesn't contain off-sequences.
455
456 - merpp: Merpp can read file format version 9 now. Please realize
457 that for file format version 9 the extraction range is different
458 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
459 the first and last 15 slices have been removed from all MUX data.
460
461 - mars: Similar to writing movies you can now select events which
462 should be displayed in your display. Therefore add the following
463 lines to your mars.rc:
464 MFEvtNumber.FileName: ganymed00223552.root
465 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
466 The input file can be a ganymed-file after (ganymed*.root) or
467 before (ganymed*-summary.root) file. For example to select all events
468 from your on sample after cuts (excluding the ThetaSq cut) use
469 MFEvtNumber.Selector: DataType.fVal>0.5
470 To show all events from your on-sample after quality cuts
471 use the summary file instead.
472
473 - mars: new ways to call mars are implemented. Instead
474 of calling
475 mars filename.root
476 you can now also use
477 mars sequence.txt
478 or
479 mars sequence.txt inputpath
480 or replace sequence.txt by the sequence number if the default
481 sequence file should be used.
482
483 - mars: The default size has been increased
484
485 - mars: There are two new heckboxes which allow to switch off
486 the calculated image parameters
487
488 - callisto: was broken for MCs... fixed.
489
490 - callisto: improved calculation of spline coefficients a lot. This
491 leads to a further improvement of the event rate calibrating MUX
492 data of about 15% (175evt/s instead of 150evt/s)
493
494 - callisto: finally the raw data we read is now real 16bit (with
495 10bit precision) for MUX data and not a stripped 8bit number
496 anymore. Due to scaling of the numbers (without precision loss
497 into an [0-256[ range, the final numbers for pedestal, pedestalrms
498 and extacted signal don't change. However, at all places where
499 raw data is directly accessed (eg. saturation and variation
500 limits in the signal- and pedestal-extraction) the numbers
501 refer still to the data's 16bit range.
502
503 - callisto: The maximum arrival time difference used in the bad
504 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
505 for both, old FADC and MUX-FADC, data.
506
507 - callisto: Be aware that callisto is now calibrating the arrival time
508 in nanoseconds rather than time slices. Also all following tasks
509 have been changed to assume ns units now. If you star data
510 calibrated with an older version it might be necessary to adapt
511 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
512 to obtain optimal results. The plot in the PulsePos tab
513 will now be in ns, too. This might also mean that the Muon
514 analysis in star might not work as perfect as expected as long
515 as old files read in.
516
517 - callisto: The calibration constants of earlier updates got lost
518 somehow. All constants have been updated.
519
520 - star: The PSF is now determined from the profile of the ArcWidth
521 instead of arcwidth/radius. The old way gave to much weight
522 to the bins with low statistics. The reference lines have been
523 updated.
524
525 - star: For speed reasons events suitable for the muon analysis
526 are now also preselected by fConcCOG<0.1 which seems to be a very
527 good preselector for muons.
528
529 - star: is now calculating a new timing parameter the Slope along
530 the major and minor axis of the shower. Therefore a numerical
531 solution of a line-fit is used. To use MHillasExt.fSlopeLong
532 and MHillasExt.fSlopeTrans don't forget to multiply it with
533 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
534
535 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
536 have been removed from MNewImagePar. They have never been good for
537 anything.
538
539 - star: Implemented a new recursive algorithm which is supposed to be
540 faster. Also implemented new cleaning oiptions, which are:
541 + CleanLevel0:
542 The cleaning level above single core pixels can be kept
543 + KeepIsolatedPixels:
544 Define whether single core pixels should be kept
545 + TimeLevel1:
546 The coincidence window in nanoseconds to single used neighbors
547 + TimeLevel2:
548 The coincidence window in nanoseconds to two used neighbors
549 + PostCleanType:
550 MOde in which a time dependent post cleaning should be applied
551 0: No post cleaning
552 1: Require for each used pixels at least one used neighbor
553 within a time-window of CleanLevel1
554 2: Require for each used pixels at least two used neighbor
555 within a time-window of CleanLevel2
556 3: Require first two and second one used neighbor
557 within a time-window of CleanLevel1 and fCleanLevel2
558 respectively
559 + RecoverIsolatedPixels:
560 - recoveres isolated core pixels if they have a used neighbor
561
562 - mars/star: The new default cleaning is:
563 + CleanLevel1: 6.0
564 + CleanLevel2: 3.0
565 + CleanTime1: 1.75
566 + CleanTime2: 1.75
567 + PostCleanType: 3
568
569 - star/ganymed: The old spark-cuts have been replaced by new ones.
570 These new spark cuts have been cross checked with the sequences
571 84720 (before splitter), 101041 (after splitter) and 223539 (new
572 FADCs). In all cases they seperate pretty well, but of course not
573 perfect. Monte Carlos have suggested to tighten the cuts a little
574 bit further at low sizes. This has been done.
575
576 - ganymed: IMPORTANT - The spark cuts have been changed to match
577 all available data more or less well. This might mean that for
578 YOUR data there are still sparks visible.
579 Whenever you do an analysis you have to make sure that NO sparks
580 survive your cuts!
581
582 - ganymed: The old hadronness and size cuts have gotten new indices
583 (10, 11). The old indices 8 and 9 now mean an additional condition
584 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
585 If you want to switch off this cut just move the line far away enough,
586 e.g. by setting c[9] to -500. Please update your ganymed.rc files
587 accordingly!
588 The unit of c[9] is deg. It is the dist at which your cut will
589 cross the slope==0. The unit of the slope is ns/deg. So if
590 you readin files calibrated with an older Mars-version you
591 have to adapt the default value for c[9] to the FADCs:
592 - Multiply by two for the MUX FADCs (run number > 200.000)
593 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
594 - Multiply by 42 for the meaning of life (run number = 200.000)
595
596 - ganymed: The old Cut0 is now called CutQ and is calculated before
597 the source position is caluclated. If you need a quality cut
598 including source dependant data (be very carefull with this!)
599 you have to use Cut0 instead.
600
601 - ganymed: now properly supports three off regions in wobble mode.
602 It will be the default from now on in ganymed_wobble.rc. To change
603 the number of off-regions use
604 NumOffSourcePositions: 1
605 in your ganymed.rc. Also by default no off-theta cut will be done
606 anymore so that you will get a background level higher than the
607 signal level in your ThetaSq plot for ThetaSq>0.2.
608 Due to this be carefull changing the scaling mode away from
609 "None". You will underestimate your signal if your scale interval
610 is not properly set.
611 (Rem: ThetaSqN is no longer needed)
612
613 - ganymed: is now storing the events of all (on- and off-)
614 source positions even in the case of more than one off-source
615 position. This should allow sponde to work properly and the
616 energy estimation is done correctly in all cases (without any
617 "nearest position" trick)
618
619 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
620 with a real pointing model for the starguider is done, calibrated
621 with more than thousand tpoints taken from this date on.
622
623 - ganymed: was broken for Wobble-MCs... fixed.
624
625 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
626 has changed. Note that your old ganymed.rc will be incompatible
627 with the new algorithms! Please check the ganymed.rc files and
628 the class description of MFMagicCuts for more information.
629 It is recommended at the moment to use identical Disp-Parametrizations
630 for on/off- and wobble-mode. If cuts are optimized only
631 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
632 should be optimized. All other values should be kept as they are.
633 If you want to do an anylsis without timing a parameters, you can
634 switch off the timing cuts by seeting parameter 7 to a very small
635 value (eg. -99). To remove the slope parameter from the disp
636 paremtrization set parameter 8 to 0.
637
638 - ganymed: The distribution of observation time versus zenith
639 angle is now shown for off- AND on-data.
640
641 - ganymed: The contents of the source position plot are no longer
642 averaged, thus a lot of (fake) events between the two wobble
643 positions have disappeared.
644
645 - ganymed: There is a new tab "CutT" it contains the VsSize plots
646 with the CutT, whihc is defined in ganymed.rc, applied. It
647 is resonable to use your theta-cut for it, to see if there is
648 something strange (sparks!) in your signal-region.
649
650 - ganymed: To choose a dataset from a collection in a dataset file
651 use the new command line option "--dataset=12345"
652
653 - optim, sponde: should now properly support three off-regions.
654 Just produce your ganymed summary files with three off-regions.
655 optim and sponde will automatically get all off events from
656 all off-regions from this file. Please do not forget to
657 set the scaling in optimwobble.C properly:
658 fit.SetScaleUser(1./3);
659 it is not yet read in automatically (will follow soon).
660 In the case of fixed Scale you can also use
661 cuts.SetThetaCut(MFMagicCuts::kOn);
662 no off-cut needed.
663 Be carefull in case of three off-regions when switching on
664 scale mode. Make sure that the scale interval is set correctly.
665
666 - sponde: sponde.rc and sponde_onoff.rc are now idetical
667
668 - sponde: the resouce files have been rewritten with a lot of
669 comments and a well working parametrization for an energy estimator
670
671 - sponde: In the estimated energy versus monte carlo energy plot the
672 contents where exchanged.... fixed.
673
674 - sponde: the so called "accurate"-mode has been removed. It didn't
675 give any improvement in accuracy, only decreased execution speed.
676
677 - sponde: the so called "simple"-mode has been removed. It didn't
678 give any improvement in simple.
679
680 - sponde: the so called "refill"-mode has been removed. It was anyhow
681 not implemented.
682
683 - sponde: now checks whether the theta distribution of your on-data
684 and the theta-distribution of your Monte Carlo sample (after
685 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
686 sample is incomplete) execution is stopped. Execution can be forced
687 using the new option --force-theta. Use this option with care!
688
689 - sponde: Proper collection areas can now be constructed also from
690 Monte Carlo samples generated with different maximum impact
691 parameters. Note that in previous version you neither got
692 a warning or failure, nor was there any obvious sign that the
693 collection area was overestimated due to usage of files with
694 different maximum impact parameters.
695
696 - sponde: If MC files with different lower energy limits are used
697 the primary MC spectrum is artificially completed down to the
698 lowest energy used at all. WARNING: that this gives correct
699 collection areas ONLY if none of the events in this region would
700 survive your cuts at all.
701
702 - sponde: the output file now contains more information about
703 the spectrum (eg. the full 2D collection area histogram).
704 Note, that this information can only be written to the file
705 if it is stored automatically via command line argument.
706 If you only store the status display from within the display
707 the information is lost.
708
709 - sponde: added a new tab "Disp". It shows the residual of the disp
710 (Disp-Dist) versus several parameters and it is meant to judge the
711 quality of the disp estimator. In the ideal case the residual is zero
712 and doesn't depend on any variable. The tab is displayed after
713 CutQ and Cut0.
714
715 - sponde: added a new tab "Energy". It shows the residual of the
716 energy (lg(estimated energy)-lg(monte carlo energy)) versus
717 several parameters and it is meant to judge the quality of the
718 energy estimator. In the ideal case the residual is zero
719 and doesn't depend on any variable. In reality even a good estimator
720 can show residuals versus Monte Carlo energy. The tab is displayed
721 after all cuts.
722
723 - sponde: added a new tab "EventDist" showing the unweighted real
724 absolute number of events of your sample after cuts. This tells
725 you how many events with this energy you had in your MC files.
726 The same information you get from the error bars of the weighted
727 histograms, but this is less intuitive.
728
729 - sponde: The spectrum plots now show the crab- and 1553-spectrum
730 for comparison. It is not meant to show these curves in
731 publications, they are only for production.
732
733 - sponde: The OriginalMC tree with the events produced by corsika
734 is now processed only once
735
736 - sponde: Finally fixed most annoying bug, which has effected the
737 last bin of the collection area. It was the problem that binnings
738 of root histograms are from 1 to n (included) but there was a C-like
739 loop in sponde from 0 to n (excluded). Now the loop also includes
740 correctly under- and overflow-bins. The worse thing with this is,
741 that for the events in the highest bin not only the bin-content
742 was wrong, but also the weights applied to these events, which could
743 in pricipal effect also other parts of the distribution (eg. due
744 to energy estimation). Fortunately it effected only a few events
745 in most cases.
746
747
748
749 *** Version 1.2 (2007/05/14)
750
751 - database: The database now has two new values Unsuitable50 and
752 Unsuitable01. They express the number of pixels which are
753 unsuitable for more than 50%, respectively more than 1%, of
754 all calibrated event. It is a more accurate number than the
755 previously used numbers, because they only take the first
756 calibration (ignoring the interleaved calibrations) into account.
757
758 - database: The database now has two other new values UnsuitableMax and
759 DeadMax. They express the maximum number of pixels which were
760 unsuitable, respectively dead, during the sequence. Because
761 of high pedestal rms (cars passing) a few events with very high
762 numbers of unsuitable pixels can happen. Not to suffer from this
763 effect we don't take the highest 0.1% of the numbers into account.
764
765 - general: fixed a bug which caused callisto and star to stop working
766 properly because the callisto output was currupted
767
768 - general: a script called scripts/makemovie has been added which
769 simplified the process of producing several movies from a single
770 sequence with different setup.
771
772 - callisto: Some more code cleanup. Started to remove old obsolete
773 code from cvs.
774
775 - callisto: The extraction of the pedestal with the extractor was
776 not random. It seems that extracting at one position is still biased
777 (for example in the first or last slices we could still suffer from
778 switching noise) Now it is completely random.
779
780 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
781 pedestal files) individual pixels could be skipped due to high
782 variations. This was already the case for the pedestal extraction
783 from the lo-gains since the beginning and properly handled
784 there, but was introduced in the extraction from the pedestal files
785 a while ago. To calculate the average value it was still divided
786 by the number of events procesed not by the number of summands
787 really summed. This let to a pedestal which was a tiny amount too
788 small (for a few piels in the order of 0.1%). This led to an slightly
789 positive offset of the randomly extracted pedestal for a few pixels.
790 I doubt that this has a big effect on the result, because the effect
791 on the individual numbers is quite small. Due to this it is suggested
792 that you rerun your calibration to make sure you are without any
793 avoidable bias.
794
795 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
796 the median rms of the absolute arrival time and expressed in significance
797 levels. This replaces the old meaning of an abolute upper limit. An
798 absolute upper limit doesn't make much sense, because in our data
799 all arrival times are shifted at the same time (in fact it might be
800 a shift of the artificial trigger w.r.t. to the light flash).
801
802 - callisto: Added a new tab "BadPixTm" which shows the time evolution
803 of the number of unsuitable pixels over the whole sequence. This
804 is usefull mainly to judge if an intermediate calibration had
805 problems.
806
807 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
808 of the number of dead pixels over the whole sequence. Dead pixels
809 in this context are unmapped pixels, i.e. pixels which could not
810 be interpolated, and thus are ignored in the further analysis.
811
812 - callisto: It is now possible to use the position of the maximum
813 of the spline as arrival time instead of the leading edge even
814 when using the integral for the signal. Therefor set the extraction
815 type to kIntegralRel ("IntegralRelative") and the relative height
816 ("HeightTm") to -1:
817 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
818 MJPedestalC1.ExtractSignal.HeightTm: -1
819
820
821
822
823 *** Version 1.1 (2007/04/27)
824
825 - general: The new class MGeomCamDwarf contains the camera geometry
826 for our prefered Dwarf camera and can be used to create general
827 geometries of roundish or hexagonal cameras.
828
829 - mars: The default cleaning is now abolute 8.5/4.0.
830
831 - mars: The resource file mars.rc now contains examples for MUX data
832
833 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
834 data containing only 10-bit information is still cooked down to
835 8-bit, by cutting away the lowest 8-bit.
836
837 - merpp: When reading raw data the data is now stored in a single
838 array. The lo-gain array is obsolete. The interface stays the same.
839
840 - callisto: To process the new MUX data use the resource file
841 callisto_mux.rc
842
843 - callisto: The -root and -raw options to read merpped raw data have
844 been removed
845
846 - callisto: If the -mc option is given the sequence-name can now be
847 replaced by the MC sequence number
848
849 - callisto: If the sequence file contains "MonteCarlo: Yes" the
850 -mc option can now be omitted
851
852 - callisto: Started further simplification by removing obsolete
853 dependancies on MCalibIntensity*Cams.
854
855 - callisto: removed unsused intensity calibration from MJCalibration
856 for further simplification
857
858 - callisto: for simplification removed references to
859 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
860 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
861 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
862 (this should at minimum change nothing at all, and at maximum
863 improve thing if these containers where somewhere not handled
864 properly)
865
866 - callisto: Added the option to write an event movie. Please use
867 this option with care (huge files) but exessively to understand
868 our events. For further documentation please refer to the
869 IACT wiki
870 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
871
872 - callisto: Improved binning for the pulse position check histogram
873
874 - callisto: The code calculating the pulse position checknow takes
875 the pedestal into account
876
877 - callisto: The arrival time is now stored with full precision this
878 helps to get rid of artefacts in histograms. For the signal this
879 is not necessray because it is displayed in log-scale anyhow
880
881 - callisto: Fixed a problem with internal exclusions. Pixels which
882 have once been marked as unsuitable didn't get the necessary
883 histograms filled anymore to be rechecked with each interleaved
884 calibration.
885
886 - callisto: The relative arrival time resolution (the rms of the
887 relative arrival time offset) is now checked against its
888 median and the median deviation, instead of the average
889 plus an absolute offset.
890
891 - callisto: The relative arrival time offset is now calculated
892 w.r.t. its median not w.r.t. to an artificial reference pixel.
893
894 - callisto: The relative time calibration now marks pixels with
895 outlaying offset as unsuitable
896
897 - callisto: The interleaved relative time calibration has been switched
898 on. The advantage is that pixels which are marked as outliers
899 now can recover. An improvement over time is not expected, because
900 the relative time calibration seems stable.
901
902 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
903 option can now be omitted.
904
905 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
906 or the option "-mc" is specified as default the monte carlo datacenter
907 paths (/magic/montecarlo/...) are used if not overwritten in the
908 dataset file.
909
910 - ganymed: The output files now contain run- and event-number for all
911 events, accessible as RunNumber.fVal and EvtNumber.fVal
912
913 - ganymed: Added a plot showing the source position in the camera also
914 for wobble mode
915
916 - ganymed: In addition to the existing task which can be setup to
917 be executed after Cut1 a final task called "EstimateEnergy"
918 has been added, executed before writing the final output
919 (ganymed00000000.root). The task setup in all three cases
920 can be choosen individually. (For all three(!) cases you
921 can for example choose MRanForestCalc. For examples see all
922 sponde*.rc and all ganymed*rc)
923
924 - ganymed: If a container "MEstimatedEnergy" is found in the
925 parameter list (eg. because it was setup by MEstimateEnergy)
926 it will be written to the output file.
927
928
929
930 *** Version 1.0 (2007/02/16)
931
932 - database: Website to plot values from the database has been added.
933
934 - database: The rate of spark events as found by star is now kept
935 and the rate after cleaning is now with spark events subtracted
936
937 - general: The changes to the interpretation of phrases lead to
938 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
939
940 - general: Added example files how you can create your own calendar
941 (eg. as christmas present) with Mars. Just run
942 root macros/tutorials/calendar.C
943
944 - general: Added a possibility to display grouped data in the plotdb.C
945 macro (and similar macros). This allows to plot hourly, nightly,
946 weekly, monthly and yearly averages.
947 For more details see the plotall function of the macro
948
949 - general: fixed the error display of the camera display. It showed
950 wrong results.
951
952 - general: fixed a memory leak when reading many MStatusDisplays
953
954 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
955 between a spherical and a parabolic mirror
956
957 - callisto: We have a new pulse position check which takes the properties
958 of the extractor automatically into account. So no need to set
959 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
960 left is done. If possible the lo-gain extraction start and hi-gain
961 extraction end is changed accordingly. If no proper extraction range
962 can be set (hi-gain too much to the left) an error is raised.
963
964 - callisto: New swapped pixels have been found and corrected
965
966 - callisto: Redone the signal extraction this includes:
967 + Unified the algorithms to extract the pedestal for all pedestal
968 extractions done
969 + Unification of hi- and lo-gain into one array
970 + Unification of hi- and lo-gain extraction for Spline and
971 Digital Filter (means now exactly the same algorithm is used,
972 not a copy-and-pasted one)
973 + Store pedestal subtracted data in a common place
974 + Improved extraction algorithms. If the algorithms search a
975 maximum but don't find one they don't return the maximum anymore
976 + Improved the extraction such that a information for signal
977 and time which is consistent is returned
978 + replaced the numerical spline with a (not slower) analytical
979 solution
980 + Lowered the saturation limit from 250 to 245 to make sure that
981 we are far away in all pixels from problems with the clock-noise
982 + The start of the lo-gain extraction is calculated from the hi-gain
983 arrival time. In case of saturation an estimation is used.
984 + the hi-gain window was extended to slice 16. This allows extraction
985 of very late pulses in single pixels or of huge hadron showers.
986 + Now uses the lo-gain extraction range for pedestal extraction,
987 not the hi-gain range in the lo-gain
988
989 - callisto: New hi-/lo-gain calibration constants have been produced
990 for all periods from the statistic of the whole period. They are
991 now used automatically depending on the periods. The old constants
992 where deviation in avarega about 2%-3%. The constants are very
993 stable from period to period (<<1%) except for exchanged channels.
994 In a few cases the constants used so far were off by 1%-2% (maybe
995 temperature effects?)
996
997 - callisto: To gain obsolete space we do not write the
998 MPedestalFundamental anymore. Also calibration and bad pixel
999 treatment is not done for it anymore because it has never been used.
1000
1001 - callisto: Fixed a bug in the seuqence handling which caused the
1002 light condition to be ignored
1003
1004 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1005 basically the same as "Cleaned" but the distribution devided into
1006 the events fullfilling a spark cut or being rejected by it.
1007 This cut can be changed from star.rc (see example inside) by
1008 the "SparkCut" directive
1009
1010 - star: Star displays now the average individual pixel-rate (IPR) versus
1011 time and the average discriminator threshold (DT) of all pixels.
1012
1013 - optim: fixed a problem with the optim-macros which was due to a bug
1014 in the new phrase parsing
1015
1016 - ganymed: To get a nice FalseSource plot (instead of the all-information
1017 debug plot displayed as a standard plot) use the context menu
1018 somewhere between the two upper plots, click on "DrawNicePlot"
1019 and enjoy the result. (It is the same context menu which contains
1020 the other options)
1021 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1022
1023 - ganymed/optim/train: The cut program, trainings- and optimization
1024 macros could run with less files found than expected from the
1025 sequence-files. No the execution is stopped in this case.
1026
1027 - ganymed: now stores the dataset in the output file with all information
1028 contained (as sequence number, sequence path, data path) so that the
1029 used dataset file can be recreated complete from the output
1030
1031 - sponde: now also allows the uasge of random forest
1032
1033 - sponde: added a plot showing the cut efficiency
1034
1035 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1036 errors (eg. effecting the collection area) because the errors of the
1037 two histograms were swapped in the calculation, which makes a difference
1038 in the case the histograms contains weighted events. Aditionally the
1039 totalarea was incorrectly taken into account, which results in too small
1040 errors, which makes a difference at low statistics were the errors
1041 or the collection area dominate.
1042
1043
1044
1045 *** Version 0.10.3 (2006/10/23)
1046
1047 - database: Implemented ObservationMode flag in websites.
1048
1049 - database: For sequences there is now also the stoptime available on the
1050 websites.
1051
1052 - database: Removed ManuallyChanged flag from sequence-info websites,
1053 as it is not needed anymore with the new sequence building algorithm.
1054
1055 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1056 Class for calculation of confidence intervals (upper limits).
1057 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1058 Please read the class instruction of TRolke for more information.
1059
1060 - general: The programs now return 0xfe if the requested resource file
1061 doesn't exist.
1062
1063 - general: Errors comming from root itself are now not output to
1064 stderr anymore but to our default (colored) log-stream.
1065
1066 - general: Changed the interface to TFormula such that now everything
1067 is parsed by TFormula, which should allow to use phrases even
1068 without paranthesis correctly parsed.
1069
1070 - callisto: replaced the AdHoc number of effective integration slices
1071 in the digital filter by an average of the correct number, averaged
1072 over all possible set of weights. This also gives correct numbers
1073 for the lo-gains which were totally wrong before.
1074
1075 - callisto: drastically reduced memory consumption by not storing
1076 all intermediate calibration results in memory anymore (we might
1077 write them into a file in the future)
1078
1079 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1080 debug plot displayed as a standard plot) use the context menu
1081 somewhere between the two upper plots, click on "DrawNicePlot"
1082 and enjoy the result. (It is the same context menu which contains
1083 the "DrawAll" option)
1084 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1085
1086
1087
1088 *** Version 0.10.2 (2006/10/15)
1089
1090 - general: changed the building of the sequence files such, that
1091 the source-/project name in case of wobble-sources is not the
1092 source/project of the first data run anymore but the new generalized
1093 wobble source/project
1094
1095 - general: Added some functions to MAstro to calculate sun and
1096 moon properties
1097
1098 - general: Added two new macros (starvisday.C and starvisyear.C)
1099 which allow to plot the visibility of several stars in one day
1100 or of one star along one year
1101
1102
1103
1104 *** Version 0.10.1 (2006/10/11)
1105
1106 - general: HTML logging output was distorted... fixed.
1107
1108 - general: Changed the writing of the sequencefiles such that only
1109 as many pedestal files as giving at least 1000 pedestal events which
1110 are nearby the first calibration run are used as pedestal runs
1111
1112 - sponde: In the calculation of the collection area(s) and the
1113 distribution for MOnte Carlo and estimated energy the error
1114 calculation was wrong because root didn't take the errors
1115 properly into account... fixed.
1116
1117
1118
1119 *** Version 0.10 (2006/10/10)
1120
1121 - general: all executables now check consistency of the root version
1122 installed with the root version used for compilation. The return
1123 code in this case is 255.
1124
1125 - general: The algorithm to build seqeunces has been redesigned
1126 completly. It is now more flexible in terms of a resource file
1127 resources/sequences.rc which can be used to partly overwrite
1128 the default algorithm and defined the important part of the
1129 algorithm. It also takes correctly into account several ways
1130 of taking wobble-data. Currently the new algorithm doesn't take
1131 the number of pedestal events anymore into account (so a sequence
1132 could have much less than 1000 pedestal events and data runs are
1133 no-more used instead)
1134
1135 - general: a lot of small changes to make the code compatible with
1136 root 5.12/00 and gcc 4.1
1137
1138 - general: Fixed some warnings thrown if more warnings are switched
1139 on in the compiler
1140
1141 - general: Added a function to MMath which returns the Median of
1142 the distribution abs(y[i]-median) but at 68:32 division instead
1143 of 50:50, which is somehow the median counterpart of the rms.
1144
1145 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1146 even if they are compressed with gzip (recommended compression
1147 is with "-1")
1148
1149 - showplot:
1150 + batch mode creation of image files now works with root 5.12/00
1151 + added support for writing bmp (though it never produces
1152 bmp which can be read by programs like xv or gimp)
1153 + added support for xml
1154 + added new option to start the display with a different size, by
1155 --display-width=nnn or --display-height=nnn
1156 + added options to define the canvas size when the display is started
1157 --canvas-width=nnn or --canvas-height=nnn
1158 the option can also be used for batch-mode conversion
1159 + added an option which automatically fits the display size to the
1160 desktop-size: --auto-size
1161
1162 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1163
1164 - merpp: allow the reports to have 1000ms due to a bug in the camera
1165 program.
1166
1167 - callisto: New swapped pixels have been found and corrected. For
1168 details see MRawRunHeader::FixAssignment()
1169
1170 - callisto: Callisto now raises an error if one of the input files could
1171 not be opened.
1172
1173 - callisto: In some rare cases it could happen that in the signal
1174 extraction of the digital filter the extractor returned nonsense
1175 results due a wrong initializion of a variable (this happens in
1176 cases in which the extracted signal is exactly zero or the
1177 digital filter couldn't slide because of a too small extraction
1178 window, which could happen in the lo-gain extraction)
1179
1180 - callisto: The lo-gains have been marked as valid in some cases
1181 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1182 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1183 smaller than the number of slices (fLoGainWindowSize) needed
1184 by the lo-gain extractor
1185
1186 - callisto: Updated absolute calibration constants (muon calibration)
1187
1188 - callisto: fixed a bug which caused the hi-gain saturation not
1189 to be handled properly in the spline (the position of the
1190 saturation was calculated incorrectly)
1191
1192 - callisto: fixed a bug which gave weird results if hi- _and_
1193 lo-gain could not be extracted properly. In some cases hi-
1194 and lo-gain have not been extracted at all and the random result
1195 got calibrated. In other cases the hi-gain was saturating and the
1196 lo-gain has not been extracted. For this a completly arbitraty
1197 scale factor was applied to the result from extracting the
1198 charge of the saturating hi-gain.
1199
1200 - callisto: improves handling of extracted signal if lo- and/or
1201 hi-gain could not be extracted properly. If no appropriate
1202 calibration of either the signal or the arrival time is possible
1203 the pixel is now markes as unsuitable instead of estimated.
1204
1205 - callisto: Fixed a problem in the spline extraction which gave
1206 weird results if the signal was extracted from the first (and
1207 highest) slice (as a workaround extraction from the first
1208 slice has been forbidden)
1209
1210 - callisto: Fixed a bug regarding the use of the QE which doesn't
1211 effect the result because the default is used anyhow.
1212 (The bug was there since 14/07/2005)
1213
1214 - callisto: Changed the default for fgLoGainStartShift to -2.4
1215
1216 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1217 factors to be always 10 for all pixels as soon as the first
1218 calibration update has happend.
1219
1220 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1221 was off by more than one slice (which gives wrong values for
1222 pixels which have saturated the hi-gain) This was a problem
1223 mainly for timing studies, not so much for the automatic standard
1224 analysis. Also the values for the Spline have been changed slightly:
1225 + Digital Filter from 1.70 to 0.95
1226 + Spline from 1.39 to 1.30
1227 The numbers were sorted out by an extensive test in the
1228 test-database.
1229
1230 - callisto: Removed the tab showing the average calibrated arrival
1231 time. It never gave useful information.
1232
1233 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1234 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1235 and both were extracted because the hi-gain was above the
1236 LoGainSwitch.
1237
1238 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1239 lo-gain pulse position (after application of LoGainOffset, which
1240 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1241 have saturated and both were extracted because the hi-gain was above
1242 the LoGainSwitch.
1243
1244 - callisto: After extensive tests a new threshold level for determination
1245 of the pulse position has been found at 50phe. This is due to the
1246 fact that for lower pulses the arrival time changes its average
1247 behaviour dramatically. It tends to the average of the extraction
1248 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1249
1250 - callisto: Added two more plots to the calibration part. The average
1251 extracted signal and the average extracted arrival time as
1252 extracted by the signal extractor (This can help debugging problems
1253 because it doesn't involve a fit)
1254
1255 - star: changed the fit for the effective on time such that initial
1256 values are calculated automatically now instead of using build
1257 in values. This makes the fit more indepedant of the underlaying
1258 rates. With a test of ~350 sequences in the test database it could
1259 be shown that the new fit gives the same result +/-1sek.
1260 The highest deviation was +5s the lowest -10s. You can now control
1261 the bahaviour with two resource values:
1262 MHEffectiveOnTime.FistBin: 3
1263 MHEffectiveOnTime.NumEvents: 12000
1264 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1265 from the resulting gamma candidates
1266
1267 - star: The Center histogram in MHHillas is now by default displayed
1268 with the colz draw-option
1269
1270 - ganymed: now produces valid error codes if failed
1271
1272 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1273 with the option "hadronness" instead of "area" or "both" if
1274 you want to use both cuts. The hadronness cut includes a fixed
1275 cut in hadronness (index 8) and a fixed cut in size (index 9).
1276
1277 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1278 the M3Long of the anti source to be not properly evaluated
1279 (actually is was evaluated as a unique random number) in case
1280 of optimization with anti-theta cut switched on. This might have
1281 lead to improper, but not necessarily wrong, optimization results.
1282
1283 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1284 how to use random forest
1285
1286 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1287 ganymed_onoff.rc. Seems to be unintentional that they were different.
1288
1289 - sponde: Since the introduction of the possibility to define a
1290 normalization energy instead of using the integral the default
1291 was not using the integral anymore but a normalization energy of
1292 1GeV. It is now the integral again.
1293
1294 - sponde: Fixed a problem in the weighting which did not allow
1295 a MC slope of -1.
1296
1297
1298
1299 *** Version 0.9.6 (2006/05/24)
1300
1301 - general: changed the binning of the azimuthal profile of the camera
1302 such that it is aligned with the 60deg boundaries.
1303
1304 - merpp: better handling of problems with the TH, TD part of the
1305 CC-REPORT for files older than 200507190 and 200412210
1306 respectively
1307
1308 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1309
1310 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1311
1312 - callisto: if an arrival time is extracted outside the fadc range is
1313 was set to the boundary before. Now a random number is assigned
1314 instead to avoid unfortunate coincidences of arrival times just
1315 by this arbitrary value.
1316
1317 - callisto: added a new option to callisto.rc which allows
1318 to set the maximum arrival time difference allowed for the
1319 badpixel algorithm to determin whether a pixels belongs to a shower:
1320 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1321
1322 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1323 to 0.9 as suggested by Stefan due to a recent study on the fraction
1324 of pixels surviving the image cleaning
1325
1326 - callisto: switched off error in case of "pulse is too much to the left"
1327
1328 - callisto: The extraction window is not adapted anymore. This means that
1329 the pulse is extracted from the full range. The draw-back is that the
1330 background (pedestal) will become slightly higher. Switching on/off
1331 the PulsePosCheck in the callisto.rc only effects filling the
1332 histograms.
1333 WARNING: If the pulse is too much to the left data is calibrated!
1334 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1335 in the database to make sure that your data is valid!
1336
1337 - star: Show also the number of stars correlated correctly by the
1338 starguider
1339
1340 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1341 than one off-source region in wobble-mode. To use it add the following to
1342 your ganymed_wobble.rc:
1343 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1344 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1345 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1346 + Cut1.ThetaCut: None
1347 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1348
1349 - ganymed: in the case the latest report is older than a default (currently
1350 one minute) and the current report will be skip the starguider
1351 correction and calibration will be reset. The maximum age can be
1352 setup from ganymed.rc by (minutes):
1353 MPointingDevCalc.MaxAge: 1.5
1354
1355 - ganymed: A first implementation showing all size-bins for the theta-sq
1356 resp. alpha-plots in a single tab automatically
1357
1358
1359
1360 *** Version 0.9.5.1 (2006/05/05)
1361
1362 - general: Added a new option "zdiff" to the Makefile which runs
1363 "cvs diff" as "make diff" would do, but with compression
1364
1365 - general: accelerated MTFillMatrix (used for eample in all training
1366 and optimization macros) by skipping some obsolete calles in the
1367 eventloop the first and second loop could be accelerated by ~20%
1368
1369 - general: Added a missing feature in the MFilterList class which
1370 prevented MFEnergySlope from working correctly in trainenergy.C
1371
1372 - general: Accelerated the random forest training and usage a bit
1373
1374 - merpp: Adapted to new raw data file format version 6
1375
1376 - merpp: fixed a problem with reading the starguider reports
1377 after 6.3.2006
1378
1379 - callisto: At some times six pixels had to be exchanged manually in the
1380 data. If the pixels to be swaped are both not found, an error was raised
1381 and calibration was stopped. Now it is assumed they are intentially not
1382 mapped and the Error has been changed to a Warning.
1383
1384 - star: Added new image cleaning based on the arrival time of the shower.
1385 The new cleaning can be accessed using the parameter "Time" instead of
1386 the the old one (like "Absolute) in the star.rc-file.
1387 Recommended parameters:
1388 + MImgCleanStd.CleanLevel1: 8.2
1389 + MImgCleanStd.CleanLevel2: 5
1390 + MImgCleanStd.CleanRings: 2
1391 + MImgCleanStd.KeepSinglePixels: No
1392
1393 - star: Simplified the calculation of the effective on time. By letting
1394 the fit start in the third bin the result should become more stable.
1395 The fit quality is now ignored for the theta-plot which is not used
1396 in the analysis later. Still better pre-cut which, for example,
1397 remove events triggered by car-light (rate changing on a short
1398 time-scale) are missing.
1399
1400 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1401 for optimization (kWeakSource) which is suggested by the Berlin
1402 people for weak sources.
1403
1404 - macros: plotdb.C:
1405 + if no dataset and no time-interval is given only sequences with
1406 an effective on-time above five minutes are plotted anymore
1407 + added a new tab "RelTime" displaying the relative on-time
1408 (effective on-time divided by the observation time)
1409
1410 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1411 the optimization became a lot faster
1412
1413 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1414 To display them just delete the pads displayed on top.
1415
1416 - ganymed: fixed a bug which could cause strange behaviour in wobble
1417 mode if no starguider information was available due to an incorrect
1418 initialization of the starguider calibration
1419
1420 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1421 be changed from within the plot. It can also be setup from the
1422 resource file using:
1423 + MHDisp.fScaleMin: 0.325
1424 + MHDisp.fScaleMax: 0.475
1425
1426 - ganymed, showplot: Fixed a problem with the fit to the off-data
1427 (HistOff) which could cause a time lag or an inifinite loop.
1428 The bug did not effect the results at all.
1429
1430 - sponde: Added a new tab showing the effective collection area after
1431 trigger (including the software trigger)
1432
1433 - sponde: MMcSpectrumWeight has a new option which allows to define
1434 the scaling factor not by the integral of the events but at
1435 a defined energy:
1436 e.g. MMcSpectrumWeight.NormEnergy: 200
1437
1438 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1439 eventloops the loop could be accelerated by ~20%
1440
1441
1442
1443 *** Version 0.9.5 (2006/03/13)
1444
1445 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1446 and added the standard Disp-parametrization
1447
1448 - macros: added a new macro datacenter/macros/plotstat.C allowing
1449 to plot statistics about the data processing
1450
1451 - macros: added a new macro to plot the muon correction coefficients
1452 versus period (macros/plot/mucal.C)
1453
1454 - showplot: path inflation for ganymed files was broken
1455
1456 - callisto: Fixed an important bug. When the number of saturating pixels
1457 were calculated the bad pixel information already available from the
1458 calibration was ignored. This yields wrong values in case pixels
1459 are broken and saturate all the time or randomly.
1460
1461 - callisto: Updated Muon calibration constants. Spline data now also uses
1462 different values for different periods
1463
1464 - star: The time-evolution shown in the effective on-time plot now displays
1465 the axis range (if there are no holes it should be similar to the
1466 effective on-time)
1467
1468 - star: Added two new image parameters:
1469 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1470 the three pixels next to the center of gravity and the size
1471 + MNewImagePar.fConcCore: The ratio of the signals of all
1472 pixels inside or touching the ellipse and the size
1473
1474 - ganymed: now stops in requested source isn't found in catalog file
1475
1476 - ganymed: Many improvements to the phi-plot in wobble mode:
1477 + with a template the ideal background is displayed
1478 + a possible camera inhomogeneity is taken into account
1479 + the anti theta cut is better supported
1480 + the phi cut is automatically calculated from the theta cut
1481 See the examples in ganymed_wobble.rc for more details.
1482
1483 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1484 times the bin-width instead of the absolute energy
1485
1486 - ganymed: New cuts for on/off and wobble mode
1487
1488 - ganymed: The smearing of the False Source plot has been increased
1489 to 0.06
1490
1491 - ganymed: The starguider calibration can now be changed from the
1492 resource file.
1493 See the examples in ganymed*.rc for more details.
1494
1495 - ganymed: added a new option for on-/off-observations
1496 MJCut.RandomSourcePosition
1497 If switched on the distribution of observation time of the source
1498 position in the camera is calculated from the on-data and randomly
1499 applied with this distrbution to the off-data.
1500
1501 - ganymed: by skipping some obsolete calles in the eventloop the
1502 first and second loop could be accelerated by ~20%
1503
1504 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1505 position in the off-data randomly according to its distribution in the
1506 on-data.
1507
1508
1509
1510 *** Version 0.9.4.3 (2006/02/13)
1511
1512 - general: Fixed a bug in most of the programs which prevented the
1513 compile date in the startup message to be displayed
1514
1515 - general: Simplified program calls. The following abbreviations
1516 are now possible:
1517 showlog callisto 55599
1518 showplot signal 55599
1519 star 55599
1520 callisto 55999
1521 ganymed 2
1522 In this cases the corrsponding root-, log-, sequence- or dataset-
1523 filename is automatically compiled using the default datacenter
1524 paths ("/magic/*")
1525
1526 - general: Fixed a long outstanding bug which made axis tick marks
1527 disappear if MDataFormula was used (eg. abs(x))
1528
1529 - general: Updated MMath with new functions to calculate the results of
1530 a exponential, logarithmic and powerlaw fits analytically.
1531
1532 - general: Updated some macros with comments:
1533 + macros/optim/optimdisp.C
1534 + macros/optim/optimenergy.C
1535 + macros/optim/optimwobble.C:
1536
1537 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1538 files) now allows adding a pre-cut like in the optimization. E.g. this
1539 is useful to perform g/h-separation cuts before training the random
1540 forest.
1541
1542 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1543 correctly assigned in the raw data assignement table. A fix to correct
1544 the assignment tabel have been implemented.
1545
1546 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1547 by 90, 180 and 270 deg.
1548
1549 - general: the macro plotdb.C now allows to highlight sequences belonging
1550 to a datset. For more details see the descritions in the macro.
1551
1552 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1553 of the display, it gave wrong results espacially for big sizes.
1554 Now the embedded canvas should always have a ratio width/height=3/2.
1555 The "Size" options have been updated with values fitting the 3/2
1556 size ratio.
1557
1558 - RanForest:
1559 + Updated the random forest classes to support also the
1560 regression method implemented by Thomas H.
1561 + added new tutorial macro how to train the random forest
1562 for energy estimation (macros/optim/rfenergyest.C)
1563 + new classes to train the random forest (still in development)
1564 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1565 + new tutorial macros for random forest training in macros/train
1566 trainenergy.C, traindisp.C, trainseparation.C
1567
1568 - mars: now allows to setup a cut in the resource file mars.rc to choose
1569 the events to be displayed, eg:
1570 Cut.Condition: {0} && {1}
1571 Cut.0: MHillas.fSize>100
1572 Cut.1: MHillas.fSize<900
1573
1574 - merpp: Made aware of the new .rep format 200510250. This includes
1575 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1576 the discriminator thresholds (MCameraTD) and the disciminator
1577 delays (MCameraTD). All of them come with the CC report and are therefor
1578 written to the CC tree.
1579
1580 - callisto: fixed a bug in the calculation of the arrival times in
1581 the Digital Filter. They were all shifted by the same amount
1582 fHiGainFirst. This caused an offset in the order of the position of
1583 the left border of the extraction window in the times calculated
1584 from high-gain and from low-gain. The bug effected only the absolute
1585 arrival times. The bug was there since 30.1.2005.
1586
1587 - callisto: Changed the ExtractionWindow for the pulse position check
1588 such that the camera inhomogeneity becomes as less as possible and
1589 comparable to the pulso position check switched off. More details
1590 on the study will be given at our result web-page.
1591
1592 - ganymed: ganymed.rc, ganymed_onoff.rc:
1593 changed to new cuts trained with 1ES1218 and Crab-data
1594 for maximum sigma*log10(excess)
1595
1596 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1597 a new option was implemented to estimate Disp (CalcDisp)
1598
1599 - ganymed: Implemented two new options which allow
1600 to overwrite the default path to search for the sequence files
1601 --ins=/magic/sequences
1602 and where to search for the image data
1603 --ind=/magic/data/star
1604
1605 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1606 dx/dy from the resource file by
1607 MSrcPosCorrect.Dx
1608 MSrcPosCorrect.Dy
1609
1610 - ganymed: fixed reading the source catalog. Only as many chars
1611 as the requested source name had were compared (If a source
1612 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1613 were requested it could happen that the coordinates of
1614 "1ES1218" were read) The source coordinates are now printed
1615 in addition to its name to the logging output.
1616
1617 - ganymed: changed the background fit in the case of a ThetaSq function
1618 from a polynomial to a exponential, this should give a big improvement
1619 for on-only analysis'
1620
1621 - ganymed/sponde: Calculation of the error of single size-/energy-
1622 bins now uses Li/Ma (5) instead of LiMa (17)
1623
1624 - sponde: Added a plot E^2*dN/dE
1625
1626 - sponde: The energy estimator plot should now show values like
1627 they are commonly used.
1628
1629 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1630 (a powerlaw with cutoff didn't work before)
1631
1632
1633
1634 *** Version 0.9.4.2 (2005/10/01)
1635
1636 - general: added new tutorial macro macros/tutorials/threshold.C:
1637 how to calculate the threshold
1638
1639 - general: added a new game. Start it from the interpreter with
1640 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1641 and MagicReversi)
1642
1643 - general: neighbor pixels in MGeoms are now sorted clockwise
1644
1645 - merpp: made aware of new format 20050829-0
1646
1647 - callisto: New scale factors from muon analysis, stored in new
1648 resource file resources/calibration.rc
1649
1650 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1651 the eventloop if something went wrong. This is necessary for the
1652 automatic processing
1653
1654 - callisto: Implemented a new treatment for the time information
1655 developed by S.Ruegamer, this should give much better response than
1656 the old very primitive algorithm. This is especially important
1657 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1658 treatment was buggy! As neighbor pixels to interpolate the
1659 arrival times always the pixels 0 to 5 were taken)
1660
1661 - callisto: In addition to the new treatment of arrival times the
1662 decision of the treatment whether a pixel contains shower
1663 information or not is used to improve the signal interpolation
1664 further. Previously interpolated pixels showed a non-zero signal
1665 do the peak searching signal extractors. Having a signal pixel
1666 beside raised the signal above the cleaning level. Thus the
1667 pixel survived cleaning to often but with a too low mean signal.
1668 By replacing empty pixels with a gaus (mean and rms from the
1669 corresponding Area entries in MPedPhotCam) this effect can
1670 be supressed.
1671
1672 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1673 got lost when the events were stored by the calibration... fixed.
1674 (This was no problem for normal image cleaning because the pixel
1675 content was artificially set to 0 not surviving standard cleaning
1676 algorithm)
1677
1678 - callisto: Fixed a bug which caused the random and peak-search pedestal
1679 extracted with an extractor to be exchanged for the first (roughly)
1680 500 events (*Extractor and *ExtractorRndm).
1681 (They were simply exchanged in callisto.cc) This bug might have been
1682 introduced in Mars 0.9.4 when the order of calculation of the two
1683 types of pedestal in callisto got exchanged. The bug only effects
1684 the first seconds of data of each sequence.
1685
1686 - star: Taking the arrival time of Muons into account the calculation
1687 of the parameters could be made independant of the noise
1688 (pedestal rms). The dependance was due to the bias of the peak search
1689 extractor. Now only a ZA dependamcy is left which is not yet fully
1690 understood.
1691
1692 - ganymed: The sequences were still not sorted correctly in any case,
1693 because they were sorted by the full qualified path name. Now they
1694 are sorted by their sequence number.
1695
1696 - ganymed: new values for the spark-event-cut
1697
1698 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1699
1700
1701
1702 *** Version 0.9.4.1 (2005/08/18)
1703
1704 - callisto: fixed some problems with the calibration in case of
1705 inteleaved events. Therefor the final and some intermediate
1706 fits are skipped which would take place on partly filled #
1707 histograms and gave wrong results or failed completely.
1708
1709 - callisto: If the intermediate finalization of the histograms
1710 calculating the mean charge of the calibration signal fails
1711 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1712
1713 - ganymed: Fixed some bugs which caused problems in On-only mode.
1714 Still the false source plot doesn't give reasonable results.
1715
1716
1717
1718 *** Version 0.9.4 (2005/08/05)
1719
1720 - general: Fixed the ZA binning. It did not correctly fit the
1721 MC binning
1722
1723 - general: Added a class to correct for the missfocussing in
1724 April (MSrcPosCorrect)
1725
1726 - general: Random Forest energy estimator should now work properly
1727
1728 - general: MHCamera now displays the profiles in deg instead of mm
1729
1730 - general: MH::SetPalette offers a lot of new palettes
1731
1732 - general: MHillas - the case of CorrXY==0 is now handled properly
1733
1734 - general: implemented the possibility to change the line and
1735 marker style of a sky-grid drawn by MAstroCatalog
1736
1737 - general: Runs in sequences and datasets are now automatically
1738 ordered (it is assumed that the order of their filenames correctly
1739 represents the order of observations) to ensure correct reading
1740 of the subsystem data
1741
1742 - general: Runs cannot be added to a sequence twice anymore. Also
1743 Sequences cannot be added twice anymore to a dataset.
1744
1745 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1746 It gave wrong results by 1./2pi
1747
1748 - showplot: got a new option to start a root interpreter, too
1749
1750 - mars: now displays a rough estimate of Disp and the third moment
1751
1752 - mars: now displays the event time MTime if available
1753
1754 - mars: show muon parameters graphically
1755
1756 - mars: now the file to open can be given as commandline
1757 argument
1758
1759 - merpp: Added support for new arehucas version >= 200507190
1760 implementing values for three temperature sensors in the
1761 counting house (MCameraAUX) and the name of the HV settings file
1762 (MCameraHV).
1763
1764 - merrp: Also fixed some problems with wrong versions numbers stated
1765 by arehucas and implemented some fixed for old versions (<200407070)
1766
1767 - callisto: MCalibrationHiLoCam can now be printed from its context
1768 menu, eg in the TBrowser
1769
1770 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1771 - 1.39 (MExtractTimeAndChargeSpline)
1772 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1773 This is important mainly for timing studies.
1774
1775 - callisto: Changed limits in MHCalibrationChargeCalc from
1776 - -100.125 to -98 (fgChargeHiGainFirst)
1777 - 1899.875 to 1902. (fgChargeHiGainLast)
1778 - -100.25 to -99 (fgChargeLoGainFirst)
1779 - 899.75 to 901. (fgChargeLoGainLast)
1780 Introduced new limits:
1781 - fgNumLoGainBlackoutLimit: 0.05
1782 - fgLoGainBlackoutLimit: 3.5
1783 - fgLoGainPickupLimit: 3.5
1784
1785 - callisto: The handling of automatic weights for the digital filter
1786 has been improved. There are now new calibration weights special
1787 for Monte Carlo calibrations.
1788
1789 - callisto: Updated Muon scale with latest results (1% difference
1790 for most data, 5% for Mar/Apr'05)
1791
1792 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1793 was saturated and the blackout-events in the low-gain exceed the
1794 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1795 This excludes those pixels which have a saturating high-gain
1796 channel, but the low-gain switch does not switch often enough
1797 to make the distribution reliable.
1798
1799 - callisto: fix a bug counting the number of saturated events. Up to now,
1800 the number of saturated slices was counted (which is one for a not too
1801 high number), but for some (pathological) pixels, many more slices
1802 saturated and produced wrong limits.
1803
1804 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1805 + MCalibrationRelTimeCam.CheckFitResults: Yes
1806 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1807 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1808 + MCalibrationRelTimeCam.CheckOscillations: Yes
1809
1810 - callisto: introduce max. number of events for intercalibration,
1811 the rest gets skipped. Default: 4096
1812 The calibration causes too many un-reliable pixels if more
1813 than about 5000 events are treated (@500 Hz) because of the
1814 mode hopping of the VCSels. However, in the past, some
1815 calibration runs have been taken (erroneously) with more
1816 than 5000 events, especially the intensity scans where
1817 a good precision is needed.
1818
1819 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1820 photo-electrons for the spline extractor by 1-2% (correctly).
1821
1822 - callisto: The intercalibration is now done using a full f-factor
1823 method instead of a simple update. This makes things slower but
1824 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1825 changes.
1826
1827 - callisto: MPedestalY3 now uses the same extraction range as the data
1828 as calculated by MPedestalY2
1829
1830 - callisto: A check of the fraction of allowed unsuitable (10%) and
1831 unreliable (30%) pixels has been addded when the conversion is
1832 calculated from interleaved events
1833
1834 - star: fixed a bug which caused MEffectiveOnTime containers not to
1835 be written. In the worst case they were skipped almost all, in the
1836 best case they were all ok. It depends on how often the new value
1837 was assigned just with an event which was skipped later by another
1838 task
1839
1840 - star: new histograms MHPointing and MHRate
1841
1842 - star: New tab (Currents) displaying the time evolution of the mean
1843 DC currents
1844
1845 - star: New tab (MeanRms) displaying the time volution of the mean
1846 Pedestal Rms
1847
1848 - star: Output now contains MReportStarguider
1849
1850 - star: Improved muon analysis. Due to the absense of a constant
1851 for the gaus fit for arc width and the fact that the arcwidth
1852 plot was a histogram instead of a profile the resulting psf
1853 became pedestal rms dependant
1854
1855 - ganymed: added new plot (MHPhi) for wobble mode as described in
1856 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1857
1858 - ganymed: corrects now (correctly?) for the misspointing in
1859 May/April 05
1860
1861 - ganymed: Two new default templates for ganymed.rc are avilable:
1862 ganymed_onoff.rc and ganymed_wobble.rc
1863
1864 - ganymed: The first version of MFMagicCuts has been released
1865
1866 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1867
1868 - ganymed, sponde: There are two new options to determin the number
1869 of bins for the signal region (NumBinsSignal) and the number of
1870 total bins (NumBinsTotal) in the MHThetaSq histogram
1871
1872 - ganymed: optimized palettes for MHDisp
1873
1874 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1875 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1876 sqrt(2) to large
1877
1878 - ganymed: The false source plot (MHDisp) is now based on Disp
1879 and a background model determined in the first loop is
1880 subtracted
1881
1882 - ganymed: MFMagicCuts are now available in the cvs. The correct
1883 solution for the disp ambiguity problem is now calculated using
1884 the third moment. The third moment cut therefor is skipped.
1885
1886 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1887 already determined by the third moment along the major axis and
1888 so its actual sign is aligned along the major axis of the shower.
1889
1890 - ganymed: If starguider data is available it is taken into account
1891 when calculating the source position. This is especially important
1892 for wobble data at high zenith angles and culmination data.
1893
1894 - ganymed: If available the starguider data is taken into account as
1895 good as it is possible without a starguider calibration. To switch
1896 it off add
1897 MPointingDevCalc.MaxAbsDev: -1
1898 to your ganymed.rc
1899
1900 - sponde: the zenith angle distribution is now weighted instead of
1901 choosen by default. This gurantees higher statistics in the highest
1902 and lowest energy bins. To switch this behaviour off use...
1903
1904 - sponde: now automatically displays the energy threshold
1905
1906
1907
1908 *** Version 0.9.3 (2005/06/03)
1909
1910 - general: MMcEvt now derived from MMcEvtBasic which should
1911 have no influence on compatibility with older camera files
1912
1913 - general: Implemented a new option to MReadReports which allows
1914 to force reading of the first event of some trees (eg. Drive-tree)
1915 before any other tree.
1916
1917 - general: Made a fix to MPointingPosCalc which assumes that the
1918 run-type is real-data if Process is called before ReInit, such
1919 that also the very first Drive-events in a run are treated
1920 correctly.
1921
1922 - shoplot now displays the filename in the title bar of the window
1923
1924 - merpp: new options: --auto-time-start --auto-time-stop which
1925 allow to cut updating with slow-control at the start- or
1926 (previousle --auto-time only allowed: and) stop-time of
1927 the run stored in the runheader.
1928
1929 - callisto: changed default of fgFallTimeHiGain in
1930 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1931 already set as default in callisto_Dec04Jan05.rc
1932
1933 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1934 now changes the filename for new weights automatically for
1935 cosmics, MC and for different calibration colors.
1936
1937 - callisto: a problem with the order of some code cause the
1938 name of the weights file in MPedestalY2 to be ignored.
1939 Wrongly the calibration_UV weights were used instead
1940 of the cosmics weights set in callisto.rc.
1941
1942 - callisto: should allow ct1 pulser data when the color is
1943 explicitly set also for pretty new runs
1944
1945 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1946 to introduce an additional scale factor (should be around 1)
1947 to adapt for slight deviations in different extractors from
1948 the MC calibration. For MC calibrations the scale factor
1949 is fixed to 1
1950
1951 - callisto: MFCosmics should handle very high signals a bit
1952 more accurate now
1953
1954 - callisto: when calculating the mean pedestal rms for different
1955 pixel sizes or sectors also kUnsuitableEvt is now taken into
1956 account - not only kUnsuitableRun
1957
1958 - callisto: '-raw' option is now the default
1959
1960 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1961 This has the advantage that mean values in the calibration (eg
1962 arrival times) are calculated more accuratly.
1963
1964 - callisto: In the resource file callisto_Dec04Jan05.rc
1965 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1966
1967 - callisto: new Hi-/Lo-Gain intercalibration constants
1968 hilocalib_sp1.root and hilocalib_sp1_mc.root
1969
1970 - callisto: changed default for MJPedestalY2.MaxEvents
1971 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1972
1973 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1974 has changed from 9.0 to 6.0. This is necessary to exclude two very
1975 ringing pixels in September which - when kept - destroy the image
1976 cleaning around them (Markus G.)
1977
1978 - callisto: (!) The Muon analysis of all data taken so far has
1979 suggested that different extractors give slightly different
1980 absolute results after calibration, due to there different
1981 handling of the calibration- and cosmics pulse shape. Although
1982 the over all calibration seems to be a bit to pesimistic (or
1983 the MC seems to be a little bit - 3-5% - too much attenuated).
1984 There for correction factors have been introduced which correct
1985 the calibration constants by
1986 0.956937799 for Digital Filter (callisto.rc)
1987 and
1988 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1989 calibration. The main advantage is, that both data types can
1990 be easily analysed together and compared to the same MC sample.
1991 The factors are choosen such, that the reference is now a
1992 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1993
1994 - star: fixed a bug which caused the first bin of the histograms
1995 vs time to disapear in PostProcess. This gave wrong results
1996 on the screen. The output and all following programs not
1997 directly accessing the histograms haven't been affected
1998
1999 - star, ganymed: Made sure that always the first Drive-tree event
2000 is read and Processed before the first data event was read.
2001
2002 - ganymed: implemented the possibility to replace the standard
2003 false source plot with a different one. For example: If
2004 you want to use a Disp based FS plot use the resource:
2005 NameHistFS: MHDisp
2006 For details about the requirements of these plots look
2007 at the corresponding classes
2008
2009 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2010 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2011 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2012 case MAlphaFitter is setup correctly. For On-Only optimization
2013 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2014 RunOn() instead of Run(). For energy estimation MJOptimize
2015 has been replaced by MJOptimizeEnergy
2016
2017 - sponde: The input MC spectrum can now be weighted to fake a
2018 different spectrum. This is done via MMcSpectrumWeight. For
2019 more details see the class description and sponde.rc
2020
2021 - sponde: The paremeter comparsion plots are not scaled by
2022 their entries anymore. Instead the MC plot is scaled by using
2023 the result spectrum of the analysis. If the input MC spectrum
2024 and the result spectrum has different slopes the absolut
2025 normalization is normally wrong.
2026
2027
2028
2029 *** Version 0.9.2 (2005/05/20)
2030
2031 - general: Changed the default paths for calibrated data and image
2032 files. (The implemented access to these files doesn't yet exist)
2033
2034 - general: support for MRunIter has been removed from the job classes
2035 (use the setter functions of MSeqeunce instead)
2036
2037 - general: ProcessFile has been renamed to Process in all job classes,
2038 because ProcessFile is missleading
2039
2040 - general: The storage of the palette in MHCamera is now possible
2041
2042 - general: new bits describing unsuitable and unreliable pixels have
2043 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2044 kDeadPedestalRms, kFluctuatingArrivalTimes
2045
2046 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2047 versions newer than V200404070
2048
2049 - general: support for cc file versions newer than V200504130. Added
2050 support for active loads (MCameraActiveLoad) and central pixel
2051 (MCameraCentralPixel)
2052
2053 - general: added new histograms for image parameters versus size
2054 (MHVsSize)
2055
2056 - general: The eventloop now automatically calls PrintStatistics
2057
2058 - Status Display: Improved support for printing:
2059 + A default can now be set in .rootrc (for more details see
2060 MStatusDisplay::PrintPS)
2061 + A print dialog is opened so that printer and command line
2062 can be canged
2063
2064 - showlog: improved such that it handles different verbosity levels
2065 more accurate now. This mean you can suppress output when
2066 using showlog.
2067
2068 - showplot: improved
2069 + The new graphics formats have been implemented
2070 (pdf, svg, png, jpg and xpm)
2071 + Implemented an interface for printing. Because you can change
2072 the printing command from the command line you can use all
2073 the nice postscript tool. To print a booklet for example call:
2074 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2075 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2076 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2077
2078 - callisto: fixed a bug in the recognition of the calibration bit
2079 pattern. Concerns only intensity calibration. (The strength of the
2080 intensity has been updated in some cases)
2081
2082 - callisto: add a filter against PIN Diode events when running over
2083 calibration runs since some of the recent calibration runs have
2084 been taken with Pin Diode.
2085
2086 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2087 39943, 44833 in the calibration (MCalibColorSet)
2088
2089 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2090 been set to 1e-18 in callisto_Dec04_Jan05.rc
2091
2092 - callisto: in callisto_Dec04Jan05.rc: set value for
2093 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2094 statistics for the calculation of the mean pulse time
2095 of the cosmisc
2096
2097 - callisto: the charge limit in the calibration has been raised
2098 from 2.5 to 4.5
2099
2100 - callisto: new setup read from callisto.rc
2101 + MCalibCalcFromPast.fNumEventsDump
2102 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2103 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2104
2105 - callisto: MExtractTimeAndChargeSpline extractor:
2106 + The integration ranges were shifted by 0.2 FADC slices to the right.
2107 + unreliable handling of floating point values caused different
2108 results on different platform or with different compiler options:
2109 The new algorithm is numerically exact and more accurate because
2110 it doesn't calculate the integration position by multiple times
2111 adding the step-size (which results in numerical uncertanties
2112 exspecially if multiplied with large numbers)
2113 + A lot of fixes have been introduced which effects integrating the
2114 spline at the edges of the valid range. In this case any memory
2115 was randomly accessed. This behaviour can be tested replacing
2116 all MArrayF by TArrayF which perform a range check (but of course
2117 they are a lot slower)
2118 ! No result obtained with the Spline before can be trusted! Due to
2119 random memory access it might by completely random!
2120
2121 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2122 + extraction range in the high gain to 4.
2123 + weights file to cosmics_weights46.dat
2124
2125 - callisto:
2126 + introduce the check for fluctuating arrival times.
2127 + set charge limit to from 2.5 to 4.5
2128 + introduce asymmetric exclusion due to "deviating number of phes":
2129 Default: -9.0 +4.5
2130 + make deviating number of phes unsuitable (see David's findings).
2131
2132 - callisto: fixed the display of unsuitable pixels. The old change
2133 to a real profile in MHCamera broke it.
2134
2135 - callisto: The cosmics filter is used in MJCalibration now
2136 independant of the pulser color (formaly it was used only for
2137 CT1-pulser data). The threshold of number of max empty pixels
2138 has been raised from 2% to 5% in MJCalibration. The maximum
2139 fraction of rejected event is 50% otherwise the calibration has
2140 failed. The filter now ignores unsuitable pixels.
2141 Setup the filter from callisto.rc using "ContCosmics"
2142 (see MFCosmics::ReadEnv)
2143
2144 - callisto: changed default for fgOffsetFromLogain back
2145 from -2.8 to -1.8 in digital filter.
2146
2147 - callisto: for the common extractors
2148 + MExtractFixedWindow
2149 * MExtractTimeAndChargeSlidingWindow
2150 * MExtractTimeAndChargeSpline
2151 * MExtractTimeAndChargeDigitalFilter
2152 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2153 and fResolutionPerPheLoGain
2154
2155 - callisto: Updated the hi-/lo-gain intercalibration constants
2156 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2157 hilocalib_df6.root
2158
2159 - callisto: The default lo-gain extraction window for the
2160 MExtractTimeAndChargeSlidingWindow extractor has been increased
2161 from 6 to 8 to take the stretch of the pusle into account
2162
2163 - callisto (!!!): fixed an important bug in the setting of the
2164 incoming pedestal pointer to the signal extractor extracting
2165 pedestals. This bug caused the pedestals not to be subtracted
2166 correctly in the calibration afterwards. The effect was about 10%
2167 too high conversion factors for the digital filter and the spline
2168 and more than 40% for the sliding window.
2169 The bug existed since end of February! (Markus G.)
2170
2171 - star: added muon support to star. A new tab "MHMuonPar" is
2172 displayed. The lower right plot is an estimate of the point spread
2173 function. A reference value is displayed. To get the real PSF
2174 you must compare with MC. The setup for the muon analysis
2175 is done in star.rc. More informations can be found in
2176 MHSingleMuon and MHCalibParCalc
2177
2178 - star: The weather data is now displayed in star
2179
2180 - star: MEventRateCalc handles the calculation of the event rate more
2181 accurate now in case of the start of a new run inside a sequence
2182
2183 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2184 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2185 changed only minimally
2186
2187 - ganymed: (MJCut and MJOptimize) now displayes the number of
2188 excess events versus size. The energy estimation is done in
2189 MJSpectrum (sponde)
2190
2191 - ganymed: got support for using other variables than Alpha, eg. Theta.
2192 Therefor you need a class deriving from MHAlpha which supports
2193 this variable (one is already existing: MHTheta, which is now the
2194 default in ganymed). It is setup through ganymed.rc
2195
2196 - added a full featured spectrum program (sponde) which reads
2197 ganymed output and monte carlos and compiles a spectrum
2198
2199
2200
2201 *** Version 0.9.1 (2005/04/14)
2202
2203 - Fix bug on the arrival time reconstruction when using Digital
2204 Filter (in some marginal cases (10%) times were reconstructed shifted
2205 by 0.2 slices)
2206
2207 - all executables now return 2 where in previous versions -1 has
2208 been returned (gave problems with shell-scripts)
2209
2210 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2211 also done with a intercalibration input file
2212
2213 - a bug in the time fine adjustment of the digital filter has been fixed
2214
2215 - a lot of small fixes to calling TPad::Divide with a margin==0
2216
2217 - MStatusDisplay now shows the memory usage
2218
2219 - added a memory leak statistic after the eventloop
2220
2221 - MHadronness replaced by MParameterD
2222
2223 - MEnergyEst replaced by MParameterD
2224
2225 - wobble mode can now be switched on from the data-set
2226
2227 - switched on bad pixel detection for a pedestal level
2228 which is more than 5 times the variance
2229
2230 - Fixed default paths to be correct for the new data center
2231
2232 - Fixed handling of drive data. The pointing position in now
2233 copied to MPointingPos inside star for real and MC events
2234
2235 - made sure, that the sequences in a dataset are sorted by
2236 their number to ensure the correct synchronization
2237
2238 - added all resource files necessary to handle spline extraction
2239 of signal for the late 2004 and the early 2005 data
2240
2241 - update the reference lines for the december data
2242
2243 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2244 This is important for the Dec. and Jan. data where the calibration
2245 pulse position changes much.
2246
2247 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2248 filter. This corrects only an defective extraction of the MC at
2249 low-gain signals lower than 90 phes.
2250
2251 - fixed some slowdown in calibrating data with interleaved events from
2252 Jan and Dec. As a workaround made the pretty palette the default.
2253 The inverse Deep Blue Sea has a bug which slows down long calibration
2254 runs a lot.
2255
2256 - implemented new values from new starguider report as defined
2257 in TDAS00-07 V7.1 (eg SkyBrighness)
2258
2259 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2260 in starguider report (If you merpp the same reports with this version
2261 you'll get the correct units (arcmin) but a different result
2262 than with old versions (wrong units))
2263
2264 - Now the status display can also write PNG, JPEG and XPM (other file
2265 formats are still unsupported by root)
2266
2267 - added a lot of scripts and macros in directory datacenter used
2268 for automatic processing
2269
2270
2271
2272 *** Version 0.9 (2005/03/23)
2273
2274 - Calibration is now done autmatically into photo-electrons like
2275 decided by the Collaboration Board
2276
2277 - Reference lines in the display can be read from resource file
2278
2279 - Interlaced calibration events can be handled by callisto
2280
2281 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2282 and applied in callisto.
2283
2284 - class MJCalibTest can be called by callisto
2285
2286 - callisto can now run with three data types: rawdata, rootdata, MC
2287
2288 - added two classes mreport/MReportStarguider.cc and
2289 mreport/MReportStarguider.h for implementing starguider-data
2290
2291 - the output of merpp-update now contains starguider information:
2292 MReportStarguider and MTimeStarguider
2293
2294 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2295 values were lower than they should. This was more visible for high
2296 energy (Size) events.
2297
2298 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2299
2300 - added a new loop to callisto to support the correct extraction of
2301 the pedestal and pedestal rms through the signal extractor
2302
2303 - added class to perform fourier tranformation of a hexagonal structure
2304 (MHexagonalFT)
2305
2306 - added class to perform fourier tranformation of a hexagonal structure
2307 in a tasklist (MHexagonalFTCalc) example: hft.C
2308
2309 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2310 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2311 small pixels, example: extendcam.C
2312
2313 - added possibility to write data to memory (TTree) using MWriteRootFile
2314
2315 - added possibility to read a TTree stored only in memory by MReadTree
2316
2317 - new classes to deal with the interleaved calibration events:
2318 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2319
2320 - implemented filters to callisto to skip calibration events
2321
2322 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2323 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2324 the slices by statistics
2325 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2326 signal extractor without randomization
2327 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2328 with the signal extractor with randomization (extraction window is
2329 randomly fixed)
2330 The three kind of pedestal is not yet implemented (for speed reasons) as
2331 long as nobody really needs it:
2332 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2333 extracted with the signal extractor with randomization
2334
2335 - callisto now finds the pulse position in the data automatically
2336
2337 - implemented data reduction in calibrated data by reducing the precision
2338 of the stored floating point values (pedestal, rms and signal) to
2339 roughly 0.5%
2340
2341 - fixed showplot to make file format conversion (eg. converting a
2342 status display stored in a root file into a postscript file) in
2343 batch mode possible:
2344 showplot -b --save-as-ps[=outfile.ps] infile.root
2345
2346 - Allow class names as part of filter rules, eg
2347 (MFSupercuts) && (MHillas.fSize>100)
2348
2349 - fixed a lot of stuff to allow all programs to process MonteCarlo
2350 camera files.
2351
2352 - enhanced possibility to debug reading of resource file
2353
2354 - MDataChain should handle priorities of operator more
2355 accurate now
2356
2357 - completely revised the container in which the signal is stored
2358 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2359 * the new implementation is faster and
2360 * needs less storage space
2361
2362 - FIRST version which can process Monte Carlos through the
2363 whole chain of programs (callisto, star, etc)
2364
2365 - implemented new image parameters for the border length of
2366 the shower image (MNewImagePar2)
2367
2368 - implemented wobble-mode in ganymed
2369
2370 - new class (MJOptimize) taking care of all optimization processes
2371
2372
2373
2374 *** Version 0.8.6 (2004/10/05)
2375
2376 - New combined signal and time extractor
2377 MExtractTimeAndChargeDigitalFilter
2378
2379 - The Report for the trigger section in the CC run summary has been
2380 updated, and now the IPRs (Individual Pixel Rates) are available.
2381
2382 - new macros for database interaction: filldotrun.C, filldotrbk.C
2383
2384 - added new program which can convert colored output which was redirected
2385 into a file back into colored text (for example to display it with
2386 more): showlog
2387
2388 - added new program to display an MStatusArray of plots (stored with
2389 MStatusDisplay) from a file: showplot
2390
2391 - Added support for Sequences (MSequence). Sequences are blocks of run
2392 files containing the same calibration and belonging to the same
2393 source
2394
2395 - Added a new task (MTaskEnv) which can be used in setup files to switch
2396 between different tasks (for example to choose a signal extractor)
2397
2398 - Implemented automatic file splitting in MWriteRootFile
2399
2400 - After image cleaning an island index is assigned to all used pixels.
2401 The index corresponds to the order of the islands in size.
2402
2403 - added a cleaning which takes signal height _and_ arrival time into
2404 account: probability cleaning (for more details see MImgCleanStd)
2405
2406 - added a cleaning which takes takes the absolute number of photons
2407 times the area ratio as cleaning level
2408 (for more details see MImgCleanStd)
2409
2410 - Changed calculation of image parameters such, that it can be done
2411 for all used pixels or the pixels with a defined island index only
2412
2413 - implemented new image parameters displaying the number of islands,
2414 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2415
2416 - event display in executable changed to support also calibrated files
2417 (done with MJCalibrateSignal)
2418
2419 - added program doing the calibration and the signal extraction
2420 and signal calibration: callisto Most part of the setup is done
2421 by a resource file: callisto.rc
2422
2423 - implemented support for pixels with negative IDs (Raw file format
2424 version 4)
2425
2426 - implemented an new option in merpp (--auto-time) to get the time
2427 range for cc and/or caco data from the run header of the raw data
2428
2429 - New star-program (star and MJStar). Taking calibrated data from
2430 callisto/MJCalibrateSignal as input. The setup is done through
2431 a resource file: star.rc
2432
2433 - Added possibility to setup the eventloop in the mars-executable
2434 Camera Display by a resource file: mars.rc
2435
2436 - The the mars-executable Camera Display can now also read
2437 calibrated data files written by callisto/MJCalibrateSignal
2438
2439 - Added a new class which can calculate the source position in
2440 the camera from a pointing model known to be correct and
2441 the pointing model used for observations (MSrcPosFromModel)
2442
2443 - added a new version of the class calculating the effective on-time
2444 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2445 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2446 MHTimeDiffTheta.
2447
2448 - added the possibility to count how often a signal is above (or
2449 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2450 can replace MHTriggerLvl0)
2451
2452 - added ore convinient ways to set the axis-titles of your histograms
2453 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2454 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2455
2456
2457
2458 *** Version 0.8.5 (2004/08/06)
2459
2460 - new Signal Extractors: MExtractFixedWindowSpline
2461 and MExtractAmplitudeSpline
2462
2463 - implementes interleave in merpp to be able to merpp parts of a file
2464
2465 - implemented force-functionality to merpp
2466
2467 - star display to display star catalogs (MAstroCatalog)
2468
2469 - star display to 'mirror' stars to the camera (MAstroCamera)
2470
2471 - implemented a new cleaning option which allows cleaning scaled with
2472 the real ratio of the rms depending on the pixel size, not only the
2473 square root of the pixelsize (MImgCleanStd, MCameraData)
2474
2475 - removed obsolete MBlind* classes
2476
2477 - Signal extractor taking the AB flag into account implemented (this makes
2478 an odd number of slices for signal extraction possible
2479 (MExtractSignalABcorr)
2480
2481 - implemented a class extracting the pedestal from the raw-data (events)
2482 itself using empty lo-gain (MpedCalcFromLoGain)
2483
2484 - Added mean values to MPedPhotCam
2485
2486 - Added Makefile for Darwin (this OS is NOT officially supported!)
2487
2488
2489
2490 *** Version 0.8.4 (2004/04/19)
2491
2492 - new fast arrival time extractor using cubic splines:
2493 MExtractTimeFastSpline
2494
2495 - implementes multi-argument support in MDataChain
2496 ("pow(a, b)")
2497
2498 - implemented double reference support in MDataChain
2499 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2500
2501 - added support in MF for expressiond like
2502 "MHillas.fWidth<2*<MHillas.fLength"
2503
2504 - MDataChain is now able to support variables like [0], [1], ...
2505 which can be used in fit functions as parameters. The interface
2506 is implemented through the new virtual function
2507 MParContainer::SetVariables
2508
2509 - added new class MArrivalTimeCam/MArrivalTimePix:
2510 Storage containers to hold the ArrivalTime of the camera/pixel
2511
2512 - added new classes for the calibration of relative arrival times:
2513 MCalibrationRelTimePix and MCalibrationRelTimeCam
2514
2515 - added new classes to extract the signal of the blind pixel and the
2516 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2517
2518 - added new classes for the bad-pixels treatment (MBadPixels*)
2519 which are more powerfull than the old ones (MBlindPixel*)
2520 and will replace them.
2521
2522 - added filter against cosmics: MFCosmics
2523
2524 - added new class MArrivalTimeCalc2:
2525 Calculates the arrival time as the signal weighted mean of the time
2526 slices in the maximum window
2527
2528 - added a new macro call pointspreadfucntion.C that fits with a 2D
2529 gaussian the DC spot for an star. It gives you the RMS of
2530 the PSF and the center of the star, very useful for misspointing
2531 studies.
2532
2533 - added support for multi-telescope camera files. Added classes
2534 MStereoCalc and MStereoPar, classes to calculate and store shower
2535 parameters calculated from the data of two telescopes, for the MC
2536 studies regarding the MAGIC clone.
2537
2538 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2539 MC data calibrated in photons instead of ADC counts.
2540
2541 - added three macros to show the calibration and analysis chain of
2542 MC data. The macro starmc.C does both calibration and analysis, producing
2543 an output containing Hillas parameters for each event. The macro
2544 mccalibrate.C does just the calibration and writes out a file containing
2545 pixel information in photons instead of FADC data. The macro starmc2.C
2546 reads in such a file and produces an output with Hillas parameters.
2547
2548 - added MPedPhotCalc to compute pedestals in units of photons, see
2549 macro pedphotcalc.C
2550
2551 - added all class to perform the calibration, see macro calibration.C
2552
2553 - added class MFFT to perform Fast Fourier Transforms
2554
2555 - added class MSimulatedAnnealing to perform simulated annealing
2556 minimizations
2557
2558 - added new macro bootcampstandardanalysis.C which holds the skeleton
2559 of the analysis chain discussed in the december bootcamp.
2560
2561 - added support for DAQ raw data file format V2
2562
2563 - implemented an arbitrary time stamp for the events from raw-data
2564 files with file version<3. It is calculated from the run number,
2565 the date of start and the FADC clock tick from the first module
2566
2567 - implemented the correct decoding of the event time-stamp
2568 coming from the DAQ for raw-data files with file-version>2
2569
2570 - added a new classes storing the pedestals in units of photons:
2571 MPedPhotPix, MPedPhotCam
2572
2573 - added support for DC current files from the camera control
2574
2575 - added support for start- and stop-time when merpping report files
2576
2577 - added MReportCC storing the weather data from the CC-REPORT
2578
2579 - added class to fill trainings and test matrices (MTFillMatrix)
2580
2581 - added a filter performing a software trigger (MFSoftwareTrigger)
2582
2583 - Added classes to perform parts of the standard analysis (Jobs):
2584 + MJPedestals
2585 + MJCalibration
2586 + MJExtractSignal
2587 Note: All of them are preliminary!
2588
2589 - Added Iterator to iterate over files giving only the run-number
2590
2591 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2592 the evolution of a sector vs time
2593
2594
2595
2596 *** Version 0.8.3 (2003/12/05)
2597
2598 - adapted Random Forest classes to allow the use with MC
2599 multi-telescope files which can be produced with the coming
2600 camera version 0.7.
2601
2602 - added classes to read and interprete central control report files
2603 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2604
2605 - enhanced merpp (the executable) to support .raw and .rep files.
2606
2607 - added classes for light calibration (MCalibration* and
2608 MHCalibration*) by Markus Gaug. Further work has to be and will
2609 be done soon.
2610
2611 - Added a preliminary 'synchronizer' (MReadReports) which will
2612 replace MReadMarsFile as soon as it is finished.
2613
2614 - Added a tutorial macro demonstrating how report files are merpped
2615 and how they can be read from the root file in the correct order
2616 of time (readrep.C)
2617
2618 - Added a generalized histogram (similar to MH3) called MVsTime
2619 which allows to plot variables (or rules - MDataChain - of
2620 variables) vs time. For an example have a look at tempvstime.C.
2621
2622 - Changed the name of the event trees:
2623 + Events --> Events
2624 + PedEvents --> Pedestals
2625 + CalEvents --> Calibration
2626
2627 - changed name of MTime in the event trees from MRawEvtTime to MTime
2628
2629 - added displaying the sector indices to the mars event display
2630
2631 - Magic Online Analysis (MOnA) implemented in a first version
2632 (see mona.cc, MOnlineDump and MOnlineDisplay)
2633
2634 - added classes to calculate event rate
2635 (preliminary: MEventRateCalc, MEventRate)
2636
2637 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2638
2639 - added classes dealing with the telescope pointing position (MPointing*)
2640
2641 - implemented the 'final' Mars time stamp based on some experiences with
2642 the new 'Synchonizer'
2643
2644
2645
2646 *** Version 0.8.2 (2003/11/10)
2647
2648 - accelerated standard analysis by a factor of 6-8 ...
2649 + doing precalculations in MGeomCam for the pixel area ratio
2650 + creating a look up table for the single pixels in MCerPhotEvt
2651
2652 - added task to calculates weights in case you want to 'change'
2653 the energy spectrum of a monte carlo file
2654 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2655
2656 - added a new executable star which implements the
2657 star.C macro as precompiled executable. Currently a flexible
2658 setup is not possible, but a 'input card' setup will follow.
2659
2660 - Starting to implement Multi-Telescope-Support based on the
2661 upcomming camera version 0.7. The base for a general support
2662 is implemented and the star-functionality is proven to work.
2663
2664 - Replaced Event-Display in and Camera-Display in the Mars GUI
2665 executable by a more convinient display base on MStatusDisplay.
2666
2667 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2668
2669
2670
2671 *** Version 0.8.1 (2003/10/20)
2672
2673 - added signal subtraction for pure on data by means of fitting
2674 the background in the off region or by performing a combined
2675 signal/background fit. Provides necessary histograms for
2676 obtaining energy spectra and a light curve.
2677
2678 - added classes to perform and study the selection of the
2679 2nd Level Trigger on MC data (example in triglvl2.C macro)
2680
2681 - added pedestal calculation
2682
2683 - implemented "democratic cleaning" (tail cut value proportional
2684 to pixel area) according to Wolfgang's suggestion.
2685
2686 - added Sigmabar treatment (calculation and basic histogramming)
2687
2688 - added basic routines to apply padding
2689
2690 - added first implementation of MARS-based source visibility plotter
2691 (needs to be linked against slalib, preliminary version)
2692
2693 - enhanced functionality of data chains: random numbers, conversion
2694 functions and access to MHMatrix objects
2695
2696 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2697 numbers under certain circumstances (runs with 0 events included)
2698
2699 - fixed a bug in the general filter MF (didn't work on some systems
2700 at all)
2701
2702 - fixed a bug in chaining files, which caused the analysis to crash or
2703 ignore files
2704
2705 - implemented more geometry classes describing the parameters used
2706 to simulate the PMT camera
2707
2708 - added new Monte Carlo classes containing the setup of the different
2709 programs in the MC chain.
2710
2711 - added a (preliminary) general task to evaluate chi-square of a given
2712 parameter in an eventloop.
2713
2714 - first implementation of a container describing the observatory
2715 location (Long, Lat, etc)
2716
2717 - added Random Forest - method for g/h-separation
2718
2719 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2720 (this means, that it is compiling, but not yet fully tested)
2721
2722 - added a new status display which can show the present status
2723 of histograms while an eventloop is running (MStatusDisplay,
2724 an example can be found at status.C)
2725
2726 - reorganized directories:
2727 classes describing the image --> mimage
2728 classes containing Monte Carlo Histograms --> mhistmc
2729 classes for Random Forest method --> mranforest
2730
2731 - added (event-)weights to fill histograms
2732
2733 - colors in logging output to screen
2734
2735 - changes to the Image Parameter declaration:
2736 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2737 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2738 + MHillasExt now derives from MParContainer instead of MHillas
2739 --> Files written with the old definition are more or less unreadable
2740
2741 - reading of reflector files
2742
2743 - display data from reflector files in the camera
2744
2745 - implemented currents (and display them in the camera)
2746
2747 - logarithmic scale in camera
2748
2749 - added class to iterate through directory contents (MDirIter)
2750
2751
2752
2753 *** Version 0.8 (2002/11/18)
2754
2755 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2756
2757 - corrected 48(!) wrong entries in the Next Neighbor table of the
2758 Magic Camera (all in the inner part of the outer ring, mostly
2759 missing a single NN)
2760
2761 - Fixed a bug in the table describing the Next Neighbours of the
2762 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2763 have any neighbour)
2764
2765 - changed trigrate.C: now it calculates the pure NSB triggers from
2766 a camera file (generated with no showers), so there is no need
2767 to introduce them by hand in the BgR array (for more details
2768 please ask Abelardo)
2769
2770 - added MHHadronness (and MHadronness) as a general facility to evaluate
2771 the quality of a gamma-hadron seperation method
2772
2773 - changed MWriteAsciiFile to accept rules (MDataChain)
2774
2775 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2776 must be replaced by calles to MWriteAsciiFile::AddColumn and
2777 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2778 changed.
2779
2780 - Implemented generalized event-matrices (one row per event)
2781 (MHMatrix)
2782
2783 - implemented the one dimensional composite probabilities
2784 (MHCompProb, MCompProbCalc, comprob.C)
2785
2786 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2787 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2788
2789 - Added a camera display displaying the pixel numbers to the
2790 event display gui.
2791
2792 - Added Monte Carlo Informations to event display gui
2793
2794 - Changed the camera display to display the pixel numbering
2795
2796 - Added three buttons to the camera display to change the palette
2797
2798 - Added the number of used and core pixels after image cleaning
2799 to MHillas
2800
2801 - Changed the algorithm used in MHillas according to TDAS 02-03
2802
2803 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2804
2805 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2806
2807 - Added fCosDeltaAlpha to MHillasSrc
2808
2809 - The numbers of photons used to calculate fConc and fConc1 in
2810 MHillasExt are now scaled with the pixel size, so that one get
2811 a four times smaller value for the bigger pixels in the outer ring.
2812
2813 - added new task to smooth the camera contents (MCameraSmooth)
2814
2815 - added possibility to use interpolated pixel values for blind pixels
2816 instead of removing it completely from the analysis
2817
2818 - Implemented the possibility to save the whole eventloop with
2819 its setup to a file. This information can be read and from
2820 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2821 and MEvtLoop::MakeMacro. If you find something not working, please
2822 report - this stuff is still in a beta phase.
2823
2824 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2825 file having crab starfield, but also for all following files - fixed
2826
2827 - MTaskList::PrintStatistics can now be instructud to print also the
2828 title, too: use PrintStatistics(0, kTRUE)
2829
2830 - Changed the image cleaning so that pixels with to many 'used'
2831 neighbors are left used (to get rid of 'holes' in events)
2832
2833 - Introduced more output to the camera displays
2834
2835 - Added an array of histograms (eg one hist per run), MHArray
2836
2837 - Added a _preliminary_ version of the reader for CT1 PreProc files
2838 (MCT1ReadPreProc)
2839
2840 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2841 (thanks to Raquel)
2842
2843 - added the first energy estimator (MEnergyEstParam, estimate.C,
2844 estfit.C) using a parametrization
2845
2846 - Added some new Monte Carlo paremeter containers used to store
2847 setup information from the MC chain (MMcConfigRunHeader,
2848 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2849
2850
2851
2852 *** Version 0.7 (2002/04/30)
2853
2854 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2855 the pedestal mean value was saved incorrectly. For files from
2856 this versions we substract 0.5 from the pedestal mean.
2857 WARNING: This may effect your results, so don't wonder...
2858
2859 - First implementation of an algorithm using only triggered events
2860 for the collection area calculation
2861
2862 - Ascii Output can now also be used for parameter containers which
2863 doesn't overload MParCointainer::AsciiWrite
2864
2865 - The Ascii Output is now also capable of writing single data members
2866 of one container
2867
2868 - You are now able to change the order of the values written to the
2869 ascii file
2870
2871 - You can now specify a conversion factor for each data member written
2872 to an ascii file. This may be usefull to change the units of the
2873 data member (eg. degrees instead of millimeters in case of the
2874 hillas parameters)
2875
2876 - Replaced old MHillas by a new structure which allows you to extend
2877 the parameters stored in MHillas very easily:
2878 see MHillas and MHillasExt
2879
2880 - Added classes to handle source dependancy of image parameters:
2881 see MHillasSrc
2882
2883 - Added container (MBinning) to have a standard input for the binning
2884 in different histograms (eg. the Energy bins should be the same in
2885 all histograms)
2886
2887 - Changed Hillas histograms from mm to deg
2888
2889 - Added the flexible binning to the hillas histograms
2890
2891 - Added a filter for the alpha parameter (MFAlpha)
2892
2893 - It is now possible to write single data members of a class object to
2894 an output stream instead of the whole container only
2895
2896 - Added a generalized filter for a data member:
2897 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2898
2899 - Added a generalized Filter parser for more difficult filter rules
2900 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2901
2902 - Added new Monte Carlo histograms:
2903 MHMcEnergyImpact and MHMcEfficiency
2904
2905 - Added many new histograms needed for the flux calculation.
2906
2907 - Added a generalized histograms which can fill and show up to three
2908 data members in either a one-, two- or three-dimensional histogram, eg:
2909 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2910
2911 - Added:
2912 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2913 * calculation of <Theta> as a function of time (MHThetabarTime)
2914 they are needed in the flux calculation in
2915 order to select for a given bin in Theta (or time) the appropriate
2916 effective collection area, which is assumed to be given as a function
2917 of Theta and the true energy
2918
2919 - Added calculation of the migration matrix in the energy
2920 (MHMcEnergyMigration):
2921 the migration matrix describes the migration from the true (E_true)
2922 to the estimated energy (E_est); it is needed to determine the
2923 distribution of E_true from the measured distribution of E_est
2924 by unfolding
2925
2926 - changed the color palette in the camera display to DeapSea.
2927
2928
2929
2930 *** Version 0.6 (2002/01/15)
2931
2932 - Introduce the option of disable pixels (MBlindPixels and
2933 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2934 able to deal with Star Field NSB.
2935
2936 - Fixed a bug in the pedestals substraction
2937
2938 - Introduced verbosity levels
2939
2940 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2941
2942 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2943 work correctly (thanks to Abelardo)
2944
2945 - Introduced correct treatment of the diffuse Night Sky Background
2946 and NSB (MMcPedestalNSB)
2947
2948 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2949
2950 - Introduced MMcRunHeaders which contains monte carlo run informations
2951
2952 - Added a 'Print'-Task (MPrint) which calls the Print function
2953 of a parameter container for each event
2954
2955 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2956
2957 - changes to be more efficient with root 3.02/06
2958
2959 - root 3.02/06 fixes:
2960 + the memory leak when reading MRawEvtData
2961 + loosing more time than necessary to update the progress bar
2962
2963 - MWriteAsciiFile is now capable of writing more than one container
2964 in a line. For example: To be able to write Monte Carlo and
2965 Hillas values (energy and alpha) in one line.
2966
2967
2968
2969 *** Version 0.5 (2001/11/06)
2970
2971 - Added new GUI functionality (Analysis)
2972
2973 - Added a camera display to be able to display events in the camera
2974 together with the calculated hillas ellipse
2975
2976 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2977 object at any state of the analysis, so that the output are several
2978 states
2979
2980 - Fixed a bug in the collection area error calculation
2981 (Thanks to Ciro and Abelardo)
2982
2983 - Fixed a bug which causes merpp to crash in some environments
2984
2985 - Implemented auto enabling scheme for Branches to speed up reading
2986 a lot (see MReadTree and MTask)
2987
2988 - Fixed a bug in the Histogram classes which caused histograms to
2989 be written to a file by MWriteRootFile without request
2990
2991 - changed the object I/O from the old stylish root I/O to the new
2992 'auto evolution scheme' This was done only for classes which are not
2993 yet used in Monte Carlo files, so that these files are still readable.
2994
2995 - Added support for a progress bar in MEvtLoop and MReadTree
2996 (see the Analysis Window in Mars for an example)
2997
2998 - Fixed a bug in the package creation which disturbed the conversion
2999 between a mars version unpacked from a tar file and the repository.
3000
3001 - Changed the code to writer merpped (converted into root format)
3002 raw files, to get faster (around 10%)
3003
3004
3005
3006 *** Version 0.4 (2001/09/20)
3007
3008 - This release is made to compile on a root version >= 3.00
3009
3010 - Fixed a bug which causes MReadTree to read the first file only
3011
3012 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3013
3014 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3015
3016 - Added a task to write several container to a root file (MWriteRootFile)
3017
3018 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3019
3020 - Added calculation of the collection area (MMcCollectionAreaCalc)
3021
3022 - fixed some bugs in the Hillas calculation
3023
3024 - added filters to be able to control the task execution dependent on
3025 a parameter (for example: the number of level 1 triggers in a MC-file)
3026
3027
3028
3029 *** Version 0.3 (2001/04/23)
3030
3031 - Many demo macros added
3032
3033 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3034
3035 - Hillas Calculation added
3036
3037 - Standard image cleaning available
3038
3039 - MReadTree is now able to handle more than one file
3040 (Remark: of the same structure)
3041
3042 - Now we are able to display events in a first version of the
3043 Camera event display. To do this we must run the macro
3044 "macros/readCT1.C" to read data from CT1.
3045
3046
3047
3048 *** Version 0.2 (2001/01/24)
3049
3050 - First Implementation of a Gui to read the raw data. Start the
3051 gui with the command mars.
3052
3053
3054
3055 *** Version 0.1 (2000/12/20)
3056
3057 - First official release 0.1
3058
3059 - Changes:
3060
3061 + changed calling style of MRawPixelIterator from do...while to
3062 while-loop
Note: See TracBrowser for help on using the repository browser.