source: trunk/MagicSoft/Mars/NEWS@ 9402

Last change on this file since 9402 was 9402, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 132.0 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;ganymed:
6
7 * added new starguider calibration for sequences since 1000534
8
9
10
11== Version 2.3 (2009/03/07) ==
12
13 ;SUGGESTION
14
15 * There is no need to re-run any data because no change took place which
16 could have an effect on the output. However, if you want a
17 meaningful SrcPos plot for your MCs in sponde you must re-process
18 star for your MCs first.
19
20 ;REMARK
21
22 * File produced with this release containing a gamera geometry (which
23 are basically all files we produce per default) will not be readable
24 by older releases.
25
26 ;general
27
28 * fixed a few small bugs which could cause the display to crash in ganymed
29 and sponde
30
31 * in sequence file the date can now be omittet. In this case the
32 leading date with the underscore is missing in the expected filename
33
34 * the geometry class now also supports other geometries than just hexagons
35
36 ;automation
37
38 * added magnetic field Azimuth direction (ARRANG), currently
39 at ~ -7deg at La Palma
40
41 ;database
42
43 * plotdb.php: added default (sequences) for startup, added possibility
44 to set size of plot
45
46 * added a new table ''RunDataCheck'' which containes the rates after
47 image cleaning for every run which succeeded star. It can be
48 plotted using ''plotrundb.C''
49
50 ;merpp
51
52 * added support for Arehucas Version >= 200812140
53
54 * added support for Arehucas Version >= 200809030
55
56 ;mars
57
58 * The display now also displays the trigger pattern
59
60 * The display can now display ceres reflector (_R_) files
61
62 ;ceres
63
64 * added a uniformly distributed one-bin time jitter for the start of the
65 digitization. Otherwise the first photon would be digitized always with
66 the same alignment to the bins
67
68 * Added a plot showing the production height of the photons
69
70 * Moved the particle id from the event header to the run header
71
72 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
73
74 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
75
76 * Added many new options to control the tasks. For deatils see ''ceres.rc''
77
78 * Removed obsolete plots in pedestal and calibration mode
79
80 * Removed the non-NightSky photons from the plots where they are just
81 disturbing
82
83 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
84
85 * The daq event number now represents the readout number
86
87 * The camera ''electronics'' can now be ''switched off''
88
89 * A new tab ''Info'' now display basic things like the reflector
90 layout
91
92 * Improved reading speed for corsika files
93
94 * Improved memory handling (if a large ampount of memory was needed
95 for a single event all further events were stored in the same
96 memory and it was never freed, so the program took this memory
97 until the end)
98
99 * Converted the code from MMCS' reflector program to MSimAtmosphere
100 (instead of the tables build in for MAGIC Winter and Summer
101 atmosphere we use the values written by Corsika fitted to the
102 tabulated atmosphere given as input)
103
104 * For caluclating the displayed image parameters in ceres a basic
105 image cleaning removing isolated pixels is now done.
106
107 * The magnetic field direction (ARRANG) is now taken into account
108
109 * Added plot for the energy threshold after trigger ''Threshold''
110
111 * Added plot for the effective collection area after trigger ''TrigArea''
112
113 ;star
114
115 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
116
117 * The definition of fConcCore has slightly changed. The numbers
118 might decrease a little bit (the effect should be rather small)
119
120 ;ganymed
121
122 * added pointing model 328198
123
124 ;sponde
125
126 * The SrcPos plot for your MCs was so far meaningless because it just
127 displayes the MSrcPosCam data from the input star-files. Unfortunately,
128 this containes was never written to the star-files yet.
129
130 * A new Tab 'OnTime' is available which is an effective on-time
131 fit as in star but for all data. This is mainly for manual cross-check
132 of the effective on-time
133
134 * In some circumstances it might be necessary to re-calculate the
135 eff. on-time from the fit in the new tab, e.g. when a zenith distance
136 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
137
138 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
139 it to its own output file (for convinience)
140
141
142
143== Version 2.2 (2009/01/30) ==
144
145 ;SUGGESTION
146
147 * This release doesn't contain a major change which is expected to
148 change your results. Nevertheless there are small changes to
149 the calibration which can effect at least the first few hundred
150 events in any (mainly MUX and even more SUM) sequence a little bit.
151 So it is recommended although not necessary to reset your sequences
152 in the database before further processing.
153
154 ;NEW
155
156 * A first implementation of a Monte Carlo simulation program
157 (ceres - Camera Electronics and REflector Simulation) has been
158 implemented. It can simulate a full telescope already including
159 a complete reflector simulation and a flexible trigger and readout
160 simulation. Currently, no perfect setup is implemented and
161 especially the output of the program (data structure) should
162 be considered alpha state. Also the user interface is not yet
163 ready.
164
165 ;general
166
167 * All command line options after -- are now interpreted as
168 arguments (usually everything which doesn't start with a minus)
169 rather than options (usually everything which starts with a
170 minus). This allows to use file names starting with a -
171
172 * In all resource files you can now initialize the random number
173 generator. For details see: MJob::InitRandomNumberGenerator
174
175 * added a new program called ''readcorsika''. It's purpose is (in analogy
176 to readraw and readdaq) to read a Corsika output file (for now
177 only cherenkov output is supported) and print its contents in a
178 human readable form. It can also write the contents of this file
179 into a root-file.
180
181 * The calculation of the maximum distance to the origin in a MGeomCam
182 has been improved (edges might be further away than the sides).
183 This is just a tiny change but it might change the appearance of
184 the radial profiles a little bit.
185
186 * The default binning of the center-of-gravity plot has slightly been
187 increased
188
189 ;Database
190
191 * Added informations about the DC currents (fMinCurrents, fMedCurrents
192 and fMaxCurrents). The values are retrieved from the plots showing
193 the average DC currents of all pixels versus time.
194
195 * Websites with tables have now the opportunity to remove lines
196 ('-' button at beginning of each line) and get all lines back
197 ('+' at top of the column)
198
199 * Websites: added option to query only sequences containing sumtrigger
200 events
201
202 * Websites: added option to group by date (year, month, night) for runs
203 and sequences and enabled that combining of different group-bys,
204 e.g. status, date and source is possible
205
206 ;automatic analyis
207
208 * Rewritten producing plots in the web.
209 New plots, namely the output of plotoptical.C (extinction curve from
210 KVA), plotstat.C (status of the automatic analysis (percentage of
211 processed, analysed data etc.)) and plotusage.C (statistics of the
212 condor usage in the data center) has been are available now next to the
213 plots of plotdb.C
214 Mean values from the plots (output of the macro) are provided in a
215 txt file now.
216 The creation of the plots for callisto, star and ganymed in the web is
217 now steered via database. Consequently the plots are faster and
218 reliable up-to-date.
219 For all plots, a new layout is available facilitating the browsing
220 through the plots and providing additional information on the
221 displayed values. (tabs.php) These plots are linked from the DB
222 websites and the wiki.
223
224 ;statusdisplay
225
226 * The ''Loop'' entry in the menu bar now contains an option to pause
227 the loop and to process single events.
228
229 ;merpp
230
231 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
232 instead of RunHeaders)
233
234 * Now allows to merpp files newer than 2008/09/03.
235
236 * Added fixes for wrong (wrong or double) run- and file-numbers
237 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
238
239 ;callisto
240
241 * Extracting the pulse position for the pulse position check events
242 with sum trigger were denied. This decreased the statistics
243 extremely and therefor the resulting puse position was calculated
244 quite weak. Now sum events pass the calculation if and only if they
245 have also a level 1 trigger.
246
247 * the extraction of pedestal events and pulse position from the
248 first data events is now more automatic and makes sure that
249 a more precise number of events is extracted independent of
250 the ratio with which pedestal events or events with signals
251 are contained in the data.
252
253 * Updated Muon calibration constants for all MUX data (teh changes were
254 all smaller than 5%)
255
256 ;star
257
258 * For the calculation of the effective on time all sum-triggered events
259 were skipped. Now all Level1-triggeres events will pass. This might
260 result in a slight inaccuracy of the effective on time.
261
262 ;ganymed
263
264 * If the source position is more than 1deg away from the camera
265 center an error is raised now.
266
267 * Hopefully fixed the bug ''ganymed crashes when resized''
268
269 ;sponde
270
271 * Fixed a problem which causes the fitted spectral slope to be displayed
272 incorrectly. If you use MJSpectrum::FormFlux in your macros make
273 sure that the parameter 0 of your fit is negative.
274
275 * Added a histogram showing the read source position of your MCs
276
277
278
279== Version 2.1.1 (2008/08/04) ==
280
281 ;Database
282
283 * Added the median number of photo electrons from the calibration
284 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
285 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
286
287 * Added fTotOnTime, which is the on-time as given by the run-headers
288 (in contradiction to fAbsOnTime which comes from CC)
289
290 * Added new primaries for the new data structure (Magic II): for the
291 tables dealing with sequences (SequenceBuild Status, Sequences,
292 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
293 this is the telescope number (fTelescopeNumber) for the tables dealing
294 with runs (RunData and RunProcessStatus) this is in addition the file
295 number (fFileNumber)
296
297 * Added column fPriority to the status tables to be able to steer the order
298 in which the data is processed. As default the run, sequence and dataset
299 number are used.
300
301 ;automatic analyis
302
303 * Adapted scripts to the new data structure: They can handle now different
304 telescopes (getting the information as usual from the database).
305 The paths for Magic 2 are not yet implemented.
306
307 ;general
308
309 * should work now with root 5.20/00 (please note that root 5.20/00
310 we encounter crahses in the status display which are ot yet
311 understood)
312
313 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
314 instead of the base name of the file. This makes them easier to
315 access from the code
316
317 * Default Monte Carlo names in MSequence do not require the _E at
318 the end anymore
319
320 * where abrrevating a sequence file with a sequence number is possible
321 also "telescope:sequence" is now accepted, e.g.:
322 star 2:2000123 --out=output
323 see the programs' help for more details.
324
325 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
326 from the database. See the constructors for more details.
327
328 * MReadTree now supports friends
329
330 * MReadTree can now read also files not written by MARS and store
331 the data encapsulated in emulated MParContainers
332
333 * added a new starguider calibration valid since 15.1.08
334
335 ;showplot
336
337 * showplot can now read more than one file at once. This is especially
338 inetersting if reading files containing pure canvases
339
340 ;merpp
341
342 * we merpp the dc currents now also from the camera reports (they have
343 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
344
345 * In the automatic analysis we omit merpping of the currents from the
346 caco files and use the lower rate camera reports from the cc files
347 instead
348
349 * merpp has been redisigned to allow merpping of the cc-reports
350 of a whole sequence. This allows to design a very simple analysis:
351 mkdir output
352 ./callisto 100776 --out=output
353 ./merpp 100776 output
354 ./star 100776 --ind=output --out=output
355 Instead of the sequence number also sequence files are accepted.
356
357 * Implemented a fix for run-numbers between 1001348 and 1001396
358 which were incorrectly assigned by the cc.
359
360
361 ;callisto
362
363 * added a filter again which was was removed in the last release.
364 it removed the most brightest events. This should not change
365 any analysis result because these events are so bright that
366 they cannot be analysed anyway, but the bad-pixel plots doesn't
367 show outliers.
368
369 * updated muon calibration constants for the periods 51-57,
370 58-63 and 67-
371
372 ;star
373
374 * The camera currents are now displayed with the rate of the camera
375 reports instead of the caco reports
376
377 ;ganymed
378
379 * if mc camera files are new enough (>=8) the source position in the
380 camera is now calculated from the stored telscope and shower
381 orientation (Note, that this might not be suitable in all cases
382 depending on the aim of the study. These case still needs
383 implementation)
384
385
386
387== Version 2.1 (2008/06/18) ==
388
389 ;Database
390
391 * introduced average temperature and wind speed from star-files
392
393 * introduced average values from Pyrometer (mainly Cloudiness)
394
395 * introduced the ratio of accepted calibration events in the
396 calibration run
397
398 * introduced the average rates of the different trigger pattern,
399 e.g. the rate of pedestal and calibration events, from the signal-file
400
401 ;general
402
403 * fixed GroupBy options in plot*.C macros
404
405 * only display KVA points (not the Tuorla points) in plotoptical.C
406
407 * all programs now allow to add resources to the ones from the resource
408 file or overwrite them from the command line. This can be done like this
409 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
410 if something seems to be wrong you can debug what the program is doing
411 using the option --debug-env=3
412
413 * increased the diversity of debug levels. That also means that with -v3
414 you get now less output, i.e. only the output which is important for
415 an analysis. To get more output which helps for debugging try 4, 5 and 6.
416
417 * fixed a problem in the task synchronizing the reading of the reports
418 and the data stream. The effect was that in some circumstances the last
419 events of some trees could have been skipped. Since this is only a
420 very tiny part of the data no severe effect to your analysis results
421 is expected (an exception might be very short, i.e. singel runs,
422 datasets).
423
424 * Dataset file now allow to include the sequence file directly within
425 the dataset file and also allow to exclude single runs from the dataset.
426 (for more details see Class reference of MDataSet)
427
428 * Sequence files now allow for excluding runs from the analysis
429 (for more details see Class reference of MSequence)
430
431 * added code to process the sum-trigger flag
432
433 * the histogram classes MH3 and MHn now support profile histograms
434
435 * the histogram classes MH3 and MHn now support labels at the axis
436
437 * the Random Forest Train-classes (MJTRain*) now store the used datasets
438 in the output file
439
440 * the MFMagicCuts have a new option to allow a linear area cut (for
441 special studies)
442
443 * The liniking of the shared object is now done into a file defined
444 by 'mktemp'. This should be a local file system which accelerates
445 liniking a lot.
446
447 * The code has been prepared for compilation with root 5.18/00d
448
449 * The MHEnergyEst histogram now shows the distribution of
450 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
451 and (Eest-Emc)/Emc vs Emc.
452
453 * fixed mars (event display) for merpped raw-data and MC data
454
455 * adapted the synatx of sequence files to allow for the new run/file
456 scheme. For more details see class description of MSequence
457
458 ;showplot
459
460 * Added support for tiff files
461
462 * Added support for csv files (tables containing tab number,
463 name and title)
464
465 * Tabs now can have a title which is displayed in the postscript file
466
467 * When multiple file are written at once (e.g. pngs from a display)
468 it is now possible to use the tab name and or tab number in the
469 file name. For details see showplos's help.
470
471 ;merpp
472
473 * Implemented cc file version 2008-02-20/0
474
475 * Implemented cc file version 2008-05-19/0
476
477 * With new options merpping can be restricted (in addition to the
478 run-number) also by telescope and file number.
479 For details see "merpp --help"
480
481 * Implemented raw data format 11 (the most important change, except
482 from plenty of changes in the format definition, is the addition
483 of the file-number in the header) If nobody makes a mistake this
484 format should have the advantage that it is by definition forward
485 compatible, so old programs will be able to read newer formats.
486
487 * Added Pyrometer information to default output (stored in a new Tree
488 Pyrometer, needs a complete new merpp, i.e. new calibration)
489
490 * Merpping (also update) can now be restricted to one single report.
491 For example:
492 If you want to update an old file with Pyrometer information call
493 merpp --only=Pyrometer --update
494
495 ;callisto
496
497 * in the pedestal processing now at least 50 processed events are
498 required for succeeding.
499
500 * the signal and calib files now contain also the sequence information
501
502 * the two MPedestalCam in the calib file now have proper names
503 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
504
505 * Both pedestal cams now contain the number of events processed
506
507 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
508 i.e. for the extraction of the calibration pulses basically the average
509 over all events of the first slice instead of all slices was used.
510 Since pedestal and calibration constants are continously recalculated
511 this only effected the very first events of every sequence.
512
513 * For the extraction of the position of the maximum sample now the
514 extraction range is set automatically to the extraction window,
515 before the whole accessible range was used.
516
517 * If the number of samples in the events and the number of samples
518 in the run-header disagrees now an error is raised (this can
519 happen in not well simulated Monte Carlo files)
520
521 * In the case of MUX-data pedestal events with the lvl1 trigger flag
522 could survive into the pedestal calculation -- fixed.
523
524 * Tab "TrigPat" added showing the distribution of the trigger pattern
525 as found in the run-files (normalized with the run length)
526
527 * The selection of events from the trigger pattern has been improved.
528 If the trigger pattern is corrupted events won't pass anymore.
529
530 * Added a new command line option --dev-null to suppress output of
531 Y-files (this is useful for test cases)
532
533 * added a new tab "CalPos" showing the arrival time of extracted
534 interleaved calibration events
535
536 ;star
537
538 * the star file now contains also the sequence information
539
540 * Added a new command line option --dev-null to suppress output of
541 I-files (this is useful for test cases)
542
543 * Tab "Rate" added showing the distribution of the trigger pattern
544 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
545 the Y-files (normalized with the run length)
546
547 * The effective on-time calculation doesn't use events with only
548 sum-trigger anymore
549
550 * The data in the MHWeather tab has been reorganized. The never
551 working solar radiation has been removed and the data from
552 the pyrometer (cloudiness, air and sky temperature) is
553 displayed in addition.
554
555 ;ganymed/sponde
556
557 * Now data points are even shown correctly if they have error bars larger
558 than one sigma. Points with null or negative significances are omitted.
559
560 * DrawNicePlot now allows to set a projection range
561
562 * Updates pointing models. One is applied after the implementation
563 of the new LUTS in August, the other one is applied after the
564 next major change of the pointing model in October. Note that
565 these models are preliminary and give wrong results below Zd=65deg
566
567 ;sponde
568
569 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
570
571 * a new option "--force-runtime" is available. In case of very short
572 datasets (for light-curves) which are in the order of a few
573 minutes the calculated effective on-time is not very acurate because
574 it is quantizised in the order of a minute. Therefore you can switch
575 to using the real run-time instead (remakrt: this ignores any
576 dead-time!)
577
578 * a more analytical way is used to "fill" Monte Carlos into regions
579 of impact parameters which have not been simulated because the
580 trigger efficiency is assumed to be 0.
581
582 * estimated sensitivity curves for hi and lo zenith angles are shown
583 scaled to the correct observation time and collection area
584
585 * the Monte Carlo events after cuts are now written to the output file
586 if an output file given
587
588
589
590 *** Version 2.0 (2007/09/03)
591
592 - database: the position used for the pulse pos check was missing
593 in the callisto output and could thus not be filled into the DB.
594 Also the old values seemed not exactly the PulsePos used for
595 teh check.
596
597 - general: Resource file now allow an Include-Resource, i.e. you can
598 read a resource file with default settings, include it in your
599 resource file and overwrite the settings in your file. More than
600 one include file is allowed. Inclusions can be iterative.
601 Include: mydefaults.rc yourdefaults.rc
602 The resources in the first file have higher priority than the
603 second file.
604
605 - general: Now the output files (calib*.root, etc) also contain the
606 resource file (to check it open it in the TBrowser and choose Print()
607 from the context menu)
608
609 - general: Dataset files now allow to overwrite the default path
610 to search for sequence and data files. Note, that the program
611 option and individual resources will overwrite it. For example:
612 SequencePath: /magic/montecarlo/sequences
613 DataPath: /magic/montecarlo/star
614
615 - general: Fixed a problem with variables in MDataPhrase. It seems
616 that only optimdisp (didn't work) was effected.
617
618 - general: Some improvements to the optim and train processing. For
619 example the ststud window now got a proper title.
620
621 - general: The "Status Display: " was removed from the window title
622 within an Eventloop.
623
624 - general: added a new flexible histogram-class (MHn) which can be used
625 for example in testing after optimizations or training to produce
626 user defined histograms.
627
628 - general: The Random Forest now allows attaching an evaluation
629 function which is applied to its output. This allows to train
630 on whatever you like (eg. train on log10(energy), but return
631 energy)
632
633 - general: The Random Forest training of energy (trainenergy.c) and
634 disp (traindisp.C) has been improved by more graphical output to
635 judge the result.
636
637 - general: The training of energy (trainenergy.C) has been improved
638 a lot by training on a different quantity than energy. It gives
639 a result which is highly independant of the source spectrum
640 and shows lower bias than all other options.
641
642 - general: Dataset files are allowed to contain collections of
643 datasets. For more details see the class reference of MDataSet.
644
645 - general: The default WobbleMode in a datset file now (if not
646 overwritten) is "auto", i.e. wobble mode is set if the dataset
647 doesn't contain off-sequences.
648
649 - merpp: Merpp can read file format version 9 now. Please realize
650 that for file format version 9 the extraction range is different
651 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
652 the first and last 15 slices have been removed from all MUX data.
653
654 - mars: Similar to writing movies you can now select events which
655 should be displayed in your display. Therefore add the following
656 lines to your mars.rc:
657 MFEvtNumber.FileName: ganymed00223552.root
658 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
659 The input file can be a ganymed-file after (ganymed*.root) or
660 before (ganymed*-summary.root) file. For example to select all events
661 from your on sample after cuts (excluding the ThetaSq cut) use
662 MFEvtNumber.Selector: DataType.fVal>0.5
663 To show all events from your on-sample after quality cuts
664 use the summary file instead.
665
666 - mars: new ways to call mars are implemented. Instead
667 of calling
668 mars filename.root
669 you can now also use
670 mars sequence.txt
671 or
672 mars sequence.txt inputpath
673 or replace sequence.txt by the sequence number if the default
674 sequence file should be used.
675
676 - mars: The default size has been increased
677
678 - mars: There are two new heckboxes which allow to switch off
679 the calculated image parameters
680
681 - callisto: was broken for MCs... fixed.
682
683 - callisto: improved calculation of spline coefficients a lot. This
684 leads to a further improvement of the event rate calibrating MUX
685 data of about 15% (175evt/s instead of 150evt/s)
686
687 - callisto: finally the raw data we read is now real 16bit (with
688 10bit precision) for MUX data and not a stripped 8bit number
689 anymore. Due to scaling of the numbers (without precision loss
690 into an [0-256[ range, the final numbers for pedestal, pedestalrms
691 and extacted signal don't change. However, at all places where
692 raw data is directly accessed (eg. saturation and variation
693 limits in the signal- and pedestal-extraction) the numbers
694 refer still to the data's 16bit range.
695
696 - callisto: The maximum arrival time difference used in the bad
697 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
698 for both, old FADC and MUX-FADC, data.
699
700 - callisto: Be aware that callisto is now calibrating the arrival time
701 in nanoseconds rather than time slices. Also all following tasks
702 have been changed to assume ns units now. If you star data
703 calibrated with an older version it might be necessary to adapt
704 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
705 to obtain optimal results. The plot in the PulsePos tab
706 will now be in ns, too. This might also mean that the Muon
707 analysis in star might not work as perfect as expected as long
708 as old files read in.
709
710 - callisto: The calibration constants of earlier updates got lost
711 somehow. All constants have been updated.
712
713 - star: The PSF is now determined from the profile of the ArcWidth
714 instead of arcwidth/radius. The old way gave to much weight
715 to the bins with low statistics. The reference lines have been
716 updated.
717
718 - star: For speed reasons events suitable for the muon analysis
719 are now also preselected by fConcCOG<0.1 which seems to be a very
720 good preselector for muons.
721
722 - star: is now calculating a new timing parameter the Slope along
723 the major and minor axis of the shower. Therefore a numerical
724 solution of a line-fit is used. To use MHillasExt.fSlopeLong
725 and MHillasExt.fSlopeTrans don't forget to multiply it with
726 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
727
728 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
729 have been removed from MNewImagePar. They have never been good for
730 anything.
731
732 - star: Implemented a new recursive algorithm which is supposed to be
733 faster. Also implemented new cleaning oiptions, which are:
734 + CleanLevel0:
735 The cleaning level above single core pixels can be kept
736 + KeepIsolatedPixels:
737 Define whether single core pixels should be kept
738 + TimeLevel1:
739 The coincidence window in nanoseconds to single used neighbors
740 + TimeLevel2:
741 The coincidence window in nanoseconds to two used neighbors
742 + PostCleanType:
743 MOde in which a time dependent post cleaning should be applied
744 0: No post cleaning
745 1: Require for each used pixels at least one used neighbor
746 within a time-window of CleanLevel1
747 2: Require for each used pixels at least two used neighbor
748 within a time-window of CleanLevel2
749 3: Require first two and second one used neighbor
750 within a time-window of CleanLevel1 and fCleanLevel2
751 respectively
752 + RecoverIsolatedPixels:
753 - recoveres isolated core pixels if they have a used neighbor
754
755 - mars/star: The new default cleaning is:
756 + CleanLevel1: 6.0
757 + CleanLevel2: 3.0
758 + CleanTime1: 1.75
759 + CleanTime2: 1.75
760 + PostCleanType: 3
761
762 - star/ganymed: The old spark-cuts have been replaced by new ones.
763 These new spark cuts have been cross checked with the sequences
764 84720 (before splitter), 101041 (after splitter) and 223539 (new
765 FADCs). In all cases they seperate pretty well, but of course not
766 perfect. Monte Carlos have suggested to tighten the cuts a little
767 bit further at low sizes. This has been done.
768
769 - ganymed: IMPORTANT - The spark cuts have been changed to match
770 all available data more or less well. This might mean that for
771 YOUR data there are still sparks visible.
772 Whenever you do an analysis you have to make sure that NO sparks
773 survive your cuts!
774
775 - ganymed: The old hadronness and size cuts have gotten new indices
776 (10, 11). The old indices 8 and 9 now mean an additional condition
777 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
778 If you want to switch off this cut just move the line far away enough,
779 e.g. by setting c[9] to -500. Please update your ganymed.rc files
780 accordingly!
781 The unit of c[9] is deg. It is the dist at which your cut will
782 cross the slope==0. The unit of the slope is ns/deg. So if
783 you readin files calibrated with an older Mars-version you
784 have to adapt the default value for c[9] to the FADCs:
785 - Multiply by two for the MUX FADCs (run number > 200.000)
786 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
787 - Multiply by 42 for the meaning of life (run number = 200.000)
788
789 - ganymed: The old Cut0 is now called CutQ and is calculated before
790 the source position is caluclated. If you need a quality cut
791 including source dependant data (be very carefull with this!)
792 you have to use Cut0 instead.
793
794 - ganymed: now properly supports three off regions in wobble mode.
795 It will be the default from now on in ganymed_wobble.rc. To change
796 the number of off-regions use
797 NumOffSourcePositions: 1
798 in your ganymed.rc. Also by default no off-theta cut will be done
799 anymore so that you will get a background level higher than the
800 signal level in your ThetaSq plot for ThetaSq>0.2.
801 Due to this be carefull changing the scaling mode away from
802 "None". You will underestimate your signal if your scale interval
803 is not properly set.
804 (Rem: ThetaSqN is no longer needed)
805
806 - ganymed: is now storing the events of all (on- and off-)
807 source positions even in the case of more than one off-source
808 position. This should allow sponde to work properly and the
809 energy estimation is done correctly in all cases (without any
810 "nearest position" trick)
811
812 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
813 with a real pointing model for the starguider is done, calibrated
814 with more than thousand tpoints taken from this date on.
815
816 - ganymed: was broken for Wobble-MCs... fixed.
817
818 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
819 has changed. Note that your old ganymed.rc will be incompatible
820 with the new algorithms! Please check the ganymed.rc files and
821 the class description of MFMagicCuts for more information.
822 It is recommended at the moment to use identical Disp-Parametrizations
823 for on/off- and wobble-mode. If cuts are optimized only
824 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
825 should be optimized. All other values should be kept as they are.
826 If you want to do an anylsis without timing a parameters, you can
827 switch off the timing cuts by seeting parameter 7 to a very small
828 value (eg. -99). To remove the slope parameter from the disp
829 paremtrization set parameter 8 to 0.
830
831 - ganymed: The distribution of observation time versus zenith
832 angle is now shown for off- AND on-data.
833
834 - ganymed: The contents of the source position plot are no longer
835 averaged, thus a lot of (fake) events between the two wobble
836 positions have disappeared.
837
838 - ganymed: There is a new tab "CutT" it contains the VsSize plots
839 with the CutT, whihc is defined in ganymed.rc, applied. It
840 is resonable to use your theta-cut for it, to see if there is
841 something strange (sparks!) in your signal-region.
842
843 - ganymed: To choose a dataset from a collection in a dataset file
844 use the new command line option "--dataset=12345"
845
846 - optim, sponde: should now properly support three off-regions.
847 Just produce your ganymed summary files with three off-regions.
848 optim and sponde will automatically get all off events from
849 all off-regions from this file. Please do not forget to
850 set the scaling in optimwobble.C properly:
851 fit.SetScaleUser(1./3);
852 it is not yet read in automatically (will follow soon).
853 In the case of fixed Scale you can also use
854 cuts.SetThetaCut(MFMagicCuts::kOn);
855 no off-cut needed.
856 Be carefull in case of three off-regions when switching on
857 scale mode. Make sure that the scale interval is set correctly.
858
859 - sponde: sponde.rc and sponde_onoff.rc are now idetical
860
861 - sponde: the resouce files have been rewritten with a lot of
862 comments and a well working parametrization for an energy estimator
863
864 - sponde: In the estimated energy versus monte carlo energy plot the
865 contents where exchanged.... fixed.
866
867 - sponde: the so called "accurate"-mode has been removed. It didn't
868 give any improvement in accuracy, only decreased execution speed.
869
870 - sponde: the so called "simple"-mode has been removed. It didn't
871 give any improvement in simple.
872
873 - sponde: the so called "refill"-mode has been removed. It was anyhow
874 not implemented.
875
876 - sponde: now checks whether the theta distribution of your on-data
877 and the theta-distribution of your Monte Carlo sample (after
878 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
879 sample is incomplete) execution is stopped. Execution can be forced
880 using the new option --force-theta. Use this option with care!
881
882 - sponde: Proper collection areas can now be constructed also from
883 Monte Carlo samples generated with different maximum impact
884 parameters. Note that in previous version you neither got
885 a warning or failure, nor was there any obvious sign that the
886 collection area was overestimated due to usage of files with
887 different maximum impact parameters.
888
889 - sponde: If MC files with different lower energy limits are used
890 the primary MC spectrum is artificially completed down to the
891 lowest energy used at all. WARNING: that this gives correct
892 collection areas ONLY if none of the events in this region would
893 survive your cuts at all.
894
895 - sponde: the output file now contains more information about
896 the spectrum (eg. the full 2D collection area histogram).
897 Note, that this information can only be written to the file
898 if it is stored automatically via command line argument.
899 If you only store the status display from within the display
900 the information is lost.
901
902 - sponde: added a new tab "Disp". It shows the residual of the disp
903 (Disp-Dist) versus several parameters and it is meant to judge the
904 quality of the disp estimator. In the ideal case the residual is zero
905 and doesn't depend on any variable. The tab is displayed after
906 CutQ and Cut0.
907
908 - sponde: added a new tab "Energy". It shows the residual of the
909 energy (lg(estimated energy)-lg(monte carlo energy)) versus
910 several parameters and it is meant to judge the quality of the
911 energy estimator. In the ideal case the residual is zero
912 and doesn't depend on any variable. In reality even a good estimator
913 can show residuals versus Monte Carlo energy. The tab is displayed
914 after all cuts.
915
916 - sponde: added a new tab "EventDist" showing the unweighted real
917 absolute number of events of your sample after cuts. This tells
918 you how many events with this energy you had in your MC files.
919 The same information you get from the error bars of the weighted
920 histograms, but this is less intuitive.
921
922 - sponde: The spectrum plots now show the crab- and 1553-spectrum
923 for comparison. It is not meant to show these curves in
924 publications, they are only for production.
925
926 - sponde: The OriginalMC tree with the events produced by corsika
927 is now processed only once
928
929 - sponde: Finally fixed most annoying bug, which has effected the
930 last bin of the collection area. It was the problem that binnings
931 of root histograms are from 1 to n (included) but there was a C-like
932 loop in sponde from 0 to n (excluded). Now the loop also includes
933 correctly under- and overflow-bins. The worse thing with this is,
934 that for the events in the highest bin not only the bin-content
935 was wrong, but also the weights applied to these events, which could
936 in pricipal effect also other parts of the distribution (eg. due
937 to energy estimation). Fortunately it effected only a few events
938 in most cases.
939
940
941
942 *** Version 1.2 (2007/05/14)
943
944 - database: The database now has two new values Unsuitable50 and
945 Unsuitable01. They express the number of pixels which are
946 unsuitable for more than 50%, respectively more than 1%, of
947 all calibrated event. It is a more accurate number than the
948 previously used numbers, because they only take the first
949 calibration (ignoring the interleaved calibrations) into account.
950
951 - database: The database now has two other new values UnsuitableMax and
952 DeadMax. They express the maximum number of pixels which were
953 unsuitable, respectively dead, during the sequence. Because
954 of high pedestal rms (cars passing) a few events with very high
955 numbers of unsuitable pixels can happen. Not to suffer from this
956 effect we don't take the highest 0.1% of the numbers into account.
957
958 - general: fixed a bug which caused callisto and star to stop working
959 properly because the callisto output was currupted
960
961 - general: a script called scripts/makemovie has been added which
962 simplified the process of producing several movies from a single
963 sequence with different setup.
964
965 - callisto: Some more code cleanup. Started to remove old obsolete
966 code from cvs.
967
968 - callisto: The extraction of the pedestal with the extractor was
969 not random. It seems that extracting at one position is still biased
970 (for example in the first or last slices we could still suffer from
971 switching noise) Now it is completely random.
972
973 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
974 pedestal files) individual pixels could be skipped due to high
975 variations. This was already the case for the pedestal extraction
976 from the lo-gains since the beginning and properly handled
977 there, but was introduced in the extraction from the pedestal files
978 a while ago. To calculate the average value it was still divided
979 by the number of events procesed not by the number of summands
980 really summed. This let to a pedestal which was a tiny amount too
981 small (for a few piels in the order of 0.1%). This led to an slightly
982 positive offset of the randomly extracted pedestal for a few pixels.
983 I doubt that this has a big effect on the result, because the effect
984 on the individual numbers is quite small. Due to this it is suggested
985 that you rerun your calibration to make sure you are without any
986 avoidable bias.
987
988 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
989 the median rms of the absolute arrival time and expressed in significance
990 levels. This replaces the old meaning of an abolute upper limit. An
991 absolute upper limit doesn't make much sense, because in our data
992 all arrival times are shifted at the same time (in fact it might be
993 a shift of the artificial trigger w.r.t. to the light flash).
994
995 - callisto: Added a new tab "BadPixTm" which shows the time evolution
996 of the number of unsuitable pixels over the whole sequence. This
997 is usefull mainly to judge if an intermediate calibration had
998 problems.
999
1000 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1001 of the number of dead pixels over the whole sequence. Dead pixels
1002 in this context are unmapped pixels, i.e. pixels which could not
1003 be interpolated, and thus are ignored in the further analysis.
1004
1005 - callisto: It is now possible to use the position of the maximum
1006 of the spline as arrival time instead of the leading edge even
1007 when using the integral for the signal. Therefor set the extraction
1008 type to kIntegralRel ("IntegralRelative") and the relative height
1009 ("HeightTm") to -1:
1010 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1011 MJPedestalC1.ExtractSignal.HeightTm: -1
1012
1013
1014
1015
1016 *** Version 1.1 (2007/04/27)
1017
1018 - general: The new class MGeomCamDwarf contains the camera geometry
1019 for our prefered Dwarf camera and can be used to create general
1020 geometries of roundish or hexagonal cameras.
1021
1022 - mars: The default cleaning is now abolute 8.5/4.0.
1023
1024 - mars: The resource file mars.rc now contains examples for MUX data
1025
1026 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1027 data containing only 10-bit information is still cooked down to
1028 8-bit, by cutting away the lowest 8-bit.
1029
1030 - merpp: When reading raw data the data is now stored in a single
1031 array. The lo-gain array is obsolete. The interface stays the same.
1032
1033 - callisto: To process the new MUX data use the resource file
1034 callisto_mux.rc
1035
1036 - callisto: The -root and -raw options to read merpped raw data have
1037 been removed
1038
1039 - callisto: If the -mc option is given the sequence-name can now be
1040 replaced by the MC sequence number
1041
1042 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1043 -mc option can now be omitted
1044
1045 - callisto: Started further simplification by removing obsolete
1046 dependancies on MCalibIntensity*Cams.
1047
1048 - callisto: removed unsused intensity calibration from MJCalibration
1049 for further simplification
1050
1051 - callisto: for simplification removed references to
1052 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1053 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1054 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1055 (this should at minimum change nothing at all, and at maximum
1056 improve thing if these containers where somewhere not handled
1057 properly)
1058
1059 - callisto: Added the option to write an event movie. Please use
1060 this option with care (huge files) but exessively to understand
1061 our events. For further documentation please refer to the
1062 IACT wiki
1063 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1064
1065 - callisto: Improved binning for the pulse position check histogram
1066
1067 - callisto: The code calculating the pulse position checknow takes
1068 the pedestal into account
1069
1070 - callisto: The arrival time is now stored with full precision this
1071 helps to get rid of artefacts in histograms. For the signal this
1072 is not necessray because it is displayed in log-scale anyhow
1073
1074 - callisto: Fixed a problem with internal exclusions. Pixels which
1075 have once been marked as unsuitable didn't get the necessary
1076 histograms filled anymore to be rechecked with each interleaved
1077 calibration.
1078
1079 - callisto: The relative arrival time resolution (the rms of the
1080 relative arrival time offset) is now checked against its
1081 median and the median deviation, instead of the average
1082 plus an absolute offset.
1083
1084 - callisto: The relative arrival time offset is now calculated
1085 w.r.t. its median not w.r.t. to an artificial reference pixel.
1086
1087 - callisto: The relative time calibration now marks pixels with
1088 outlaying offset as unsuitable
1089
1090 - callisto: The interleaved relative time calibration has been switched
1091 on. The advantage is that pixels which are marked as outliers
1092 now can recover. An improvement over time is not expected, because
1093 the relative time calibration seems stable.
1094
1095 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1096 option can now be omitted.
1097
1098 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1099 or the option "-mc" is specified as default the monte carlo datacenter
1100 paths (/magic/montecarlo/...) are used if not overwritten in the
1101 dataset file.
1102
1103 - ganymed: The output files now contain run- and event-number for all
1104 events, accessible as RunNumber.fVal and EvtNumber.fVal
1105
1106 - ganymed: Added a plot showing the source position in the camera also
1107 for wobble mode
1108
1109 - ganymed: In addition to the existing task which can be setup to
1110 be executed after Cut1 a final task called "EstimateEnergy"
1111 has been added, executed before writing the final output
1112 (ganymed00000000.root). The task setup in all three cases
1113 can be choosen individually. (For all three(!) cases you
1114 can for example choose MRanForestCalc. For examples see all
1115 sponde*.rc and all ganymed*rc)
1116
1117 - ganymed: If a container "MEstimatedEnergy" is found in the
1118 parameter list (eg. because it was setup by MEstimateEnergy)
1119 it will be written to the output file.
1120
1121
1122
1123 *** Version 1.0 (2007/02/16)
1124
1125 - database: Website to plot values from the database has been added.
1126
1127 - database: The rate of spark events as found by star is now kept
1128 and the rate after cleaning is now with spark events subtracted
1129
1130 - general: The changes to the interpretation of phrases lead to
1131 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1132
1133 - general: Added example files how you can create your own calendar
1134 (eg. as christmas present) with Mars. Just run
1135 root macros/tutorials/calendar.C
1136
1137 - general: Added a possibility to display grouped data in the plotdb.C
1138 macro (and similar macros). This allows to plot hourly, nightly,
1139 weekly, monthly and yearly averages.
1140 For more details see the plotall function of the macro
1141
1142 - general: fixed the error display of the camera display. It showed
1143 wrong results.
1144
1145 - general: fixed a memory leak when reading many MStatusDisplays
1146
1147 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1148 between a spherical and a parabolic mirror
1149
1150 - callisto: We have a new pulse position check which takes the properties
1151 of the extractor automatically into account. So no need to set
1152 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1153 left is done. If possible the lo-gain extraction start and hi-gain
1154 extraction end is changed accordingly. If no proper extraction range
1155 can be set (hi-gain too much to the left) an error is raised.
1156
1157 - callisto: New swapped pixels have been found and corrected
1158
1159 - callisto: Redone the signal extraction this includes:
1160 + Unified the algorithms to extract the pedestal for all pedestal
1161 extractions done
1162 + Unification of hi- and lo-gain into one array
1163 + Unification of hi- and lo-gain extraction for Spline and
1164 Digital Filter (means now exactly the same algorithm is used,
1165 not a copy-and-pasted one)
1166 + Store pedestal subtracted data in a common place
1167 + Improved extraction algorithms. If the algorithms search a
1168 maximum but don't find one they don't return the maximum anymore
1169 + Improved the extraction such that a information for signal
1170 and time which is consistent is returned
1171 + replaced the numerical spline with a (not slower) analytical
1172 solution
1173 + Lowered the saturation limit from 250 to 245 to make sure that
1174 we are far away in all pixels from problems with the clock-noise
1175 + The start of the lo-gain extraction is calculated from the hi-gain
1176 arrival time. In case of saturation an estimation is used.
1177 + the hi-gain window was extended to slice 16. This allows extraction
1178 of very late pulses in single pixels or of huge hadron showers.
1179 + Now uses the lo-gain extraction range for pedestal extraction,
1180 not the hi-gain range in the lo-gain
1181
1182 - callisto: New hi-/lo-gain calibration constants have been produced
1183 for all periods from the statistic of the whole period. They are
1184 now used automatically depending on the periods. The old constants
1185 where deviation in avarega about 2%-3%. The constants are very
1186 stable from period to period (<<1%) except for exchanged channels.
1187 In a few cases the constants used so far were off by 1%-2% (maybe
1188 temperature effects?)
1189
1190 - callisto: To gain obsolete space we do not write the
1191 MPedestalFundamental anymore. Also calibration and bad pixel
1192 treatment is not done for it anymore because it has never been used.
1193
1194 - callisto: Fixed a bug in the seuqence handling which caused the
1195 light condition to be ignored
1196
1197 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1198 basically the same as "Cleaned" but the distribution devided into
1199 the events fullfilling a spark cut or being rejected by it.
1200 This cut can be changed from star.rc (see example inside) by
1201 the "SparkCut" directive
1202
1203 - star: Star displays now the average individual pixel-rate (IPR) versus
1204 time and the average discriminator threshold (DT) of all pixels.
1205
1206 - optim: fixed a problem with the optim-macros which was due to a bug
1207 in the new phrase parsing
1208
1209 - ganymed: To get a nice FalseSource plot (instead of the all-information
1210 debug plot displayed as a standard plot) use the context menu
1211 somewhere between the two upper plots, click on "DrawNicePlot"
1212 and enjoy the result. (It is the same context menu which contains
1213 the other options)
1214 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1215
1216 - ganymed/optim/train: The cut program, trainings- and optimization
1217 macros could run with less files found than expected from the
1218 sequence-files. No the execution is stopped in this case.
1219
1220 - ganymed: now stores the dataset in the output file with all information
1221 contained (as sequence number, sequence path, data path) so that the
1222 used dataset file can be recreated complete from the output
1223
1224 - sponde: now also allows the uasge of random forest
1225
1226 - sponde: added a plot showing the cut efficiency
1227
1228 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1229 errors (eg. effecting the collection area) because the errors of the
1230 two histograms were swapped in the calculation, which makes a difference
1231 in the case the histograms contains weighted events. Aditionally the
1232 totalarea was incorrectly taken into account, which results in too small
1233 errors, which makes a difference at low statistics were the errors
1234 or the collection area dominate.
1235
1236
1237
1238 *** Version 0.10.3 (2006/10/23)
1239
1240 - database: Implemented ObservationMode flag in websites.
1241
1242 - database: For sequences there is now also the stoptime available on the
1243 websites.
1244
1245 - database: Removed ManuallyChanged flag from sequence-info websites,
1246 as it is not needed anymore with the new sequence building algorithm.
1247
1248 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1249 Class for calculation of confidence intervals (upper limits).
1250 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1251 Please read the class instruction of TRolke for more information.
1252
1253 - general: The programs now return 0xfe if the requested resource file
1254 doesn't exist.
1255
1256 - general: Errors comming from root itself are now not output to
1257 stderr anymore but to our default (colored) log-stream.
1258
1259 - general: Changed the interface to TFormula such that now everything
1260 is parsed by TFormula, which should allow to use phrases even
1261 without paranthesis correctly parsed.
1262
1263 - callisto: replaced the AdHoc number of effective integration slices
1264 in the digital filter by an average of the correct number, averaged
1265 over all possible set of weights. This also gives correct numbers
1266 for the lo-gains which were totally wrong before.
1267
1268 - callisto: drastically reduced memory consumption by not storing
1269 all intermediate calibration results in memory anymore (we might
1270 write them into a file in the future)
1271
1272 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1273 debug plot displayed as a standard plot) use the context menu
1274 somewhere between the two upper plots, click on "DrawNicePlot"
1275 and enjoy the result. (It is the same context menu which contains
1276 the "DrawAll" option)
1277 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1278
1279
1280
1281 *** Version 0.10.2 (2006/10/15)
1282
1283 - general: changed the building of the sequence files such, that
1284 the source-/project name in case of wobble-sources is not the
1285 source/project of the first data run anymore but the new generalized
1286 wobble source/project
1287
1288 - general: Added some functions to MAstro to calculate sun and
1289 moon properties
1290
1291 - general: Added two new macros (starvisday.C and starvisyear.C)
1292 which allow to plot the visibility of several stars in one day
1293 or of one star along one year
1294
1295
1296
1297 *** Version 0.10.1 (2006/10/11)
1298
1299 - general: HTML logging output was distorted... fixed.
1300
1301 - general: Changed the writing of the sequencefiles such that only
1302 as many pedestal files as giving at least 1000 pedestal events which
1303 are nearby the first calibration run are used as pedestal runs
1304
1305 - sponde: In the calculation of the collection area(s) and the
1306 distribution for MOnte Carlo and estimated energy the error
1307 calculation was wrong because root didn't take the errors
1308 properly into account... fixed.
1309
1310
1311
1312 *** Version 0.10 (2006/10/10)
1313
1314 - general: all executables now check consistency of the root version
1315 installed with the root version used for compilation. The return
1316 code in this case is 255.
1317
1318 - general: The algorithm to build seqeunces has been redesigned
1319 completly. It is now more flexible in terms of a resource file
1320 resources/sequences.rc which can be used to partly overwrite
1321 the default algorithm and defined the important part of the
1322 algorithm. It also takes correctly into account several ways
1323 of taking wobble-data. Currently the new algorithm doesn't take
1324 the number of pedestal events anymore into account (so a sequence
1325 could have much less than 1000 pedestal events and data runs are
1326 no-more used instead)
1327
1328 - general: a lot of small changes to make the code compatible with
1329 root 5.12/00 and gcc 4.1
1330
1331 - general: Fixed some warnings thrown if more warnings are switched
1332 on in the compiler
1333
1334 - general: Added a function to MMath which returns the Median of
1335 the distribution abs(y[i]-median) but at 68:32 division instead
1336 of 50:50, which is somehow the median counterpart of the rms.
1337
1338 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1339 even if they are compressed with gzip (recommended compression
1340 is with "-1")
1341
1342 - showplot:
1343 + batch mode creation of image files now works with root 5.12/00
1344 + added support for writing bmp (though it never produces
1345 bmp which can be read by programs like xv or gimp)
1346 + added support for xml
1347 + added new option to start the display with a different size, by
1348 --display-width=nnn or --display-height=nnn
1349 + added options to define the canvas size when the display is started
1350 --canvas-width=nnn or --canvas-height=nnn
1351 the option can also be used for batch-mode conversion
1352 + added an option which automatically fits the display size to the
1353 desktop-size: --auto-size
1354
1355 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1356
1357 - merpp: allow the reports to have 1000ms due to a bug in the camera
1358 program.
1359
1360 - callisto: New swapped pixels have been found and corrected. For
1361 details see MRawRunHeader::FixAssignment()
1362
1363 - callisto: Callisto now raises an error if one of the input files could
1364 not be opened.
1365
1366 - callisto: In some rare cases it could happen that in the signal
1367 extraction of the digital filter the extractor returned nonsense
1368 results due a wrong initializion of a variable (this happens in
1369 cases in which the extracted signal is exactly zero or the
1370 digital filter couldn't slide because of a too small extraction
1371 window, which could happen in the lo-gain extraction)
1372
1373 - callisto: The lo-gains have been marked as valid in some cases
1374 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1375 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1376 smaller than the number of slices (fLoGainWindowSize) needed
1377 by the lo-gain extractor
1378
1379 - callisto: Updated absolute calibration constants (muon calibration)
1380
1381 - callisto: fixed a bug which caused the hi-gain saturation not
1382 to be handled properly in the spline (the position of the
1383 saturation was calculated incorrectly)
1384
1385 - callisto: fixed a bug which gave weird results if hi- _and_
1386 lo-gain could not be extracted properly. In some cases hi-
1387 and lo-gain have not been extracted at all and the random result
1388 got calibrated. In other cases the hi-gain was saturating and the
1389 lo-gain has not been extracted. For this a completly arbitraty
1390 scale factor was applied to the result from extracting the
1391 charge of the saturating hi-gain.
1392
1393 - callisto: improves handling of extracted signal if lo- and/or
1394 hi-gain could not be extracted properly. If no appropriate
1395 calibration of either the signal or the arrival time is possible
1396 the pixel is now markes as unsuitable instead of estimated.
1397
1398 - callisto: Fixed a problem in the spline extraction which gave
1399 weird results if the signal was extracted from the first (and
1400 highest) slice (as a workaround extraction from the first
1401 slice has been forbidden)
1402
1403 - callisto: Fixed a bug regarding the use of the QE which doesn't
1404 effect the result because the default is used anyhow.
1405 (The bug was there since 14/07/2005)
1406
1407 - callisto: Changed the default for fgLoGainStartShift to -2.4
1408
1409 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1410 factors to be always 10 for all pixels as soon as the first
1411 calibration update has happend.
1412
1413 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1414 was off by more than one slice (which gives wrong values for
1415 pixels which have saturated the hi-gain) This was a problem
1416 mainly for timing studies, not so much for the automatic standard
1417 analysis. Also the values for the Spline have been changed slightly:
1418 + Digital Filter from 1.70 to 0.95
1419 + Spline from 1.39 to 1.30
1420 The numbers were sorted out by an extensive test in the
1421 test-database.
1422
1423 - callisto: Removed the tab showing the average calibrated arrival
1424 time. It never gave useful information.
1425
1426 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1427 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1428 and both were extracted because the hi-gain was above the
1429 LoGainSwitch.
1430
1431 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1432 lo-gain pulse position (after application of LoGainOffset, which
1433 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1434 have saturated and both were extracted because the hi-gain was above
1435 the LoGainSwitch.
1436
1437 - callisto: After extensive tests a new threshold level for determination
1438 of the pulse position has been found at 50phe. This is due to the
1439 fact that for lower pulses the arrival time changes its average
1440 behaviour dramatically. It tends to the average of the extraction
1441 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1442
1443 - callisto: Added two more plots to the calibration part. The average
1444 extracted signal and the average extracted arrival time as
1445 extracted by the signal extractor (This can help debugging problems
1446 because it doesn't involve a fit)
1447
1448 - star: changed the fit for the effective on time such that initial
1449 values are calculated automatically now instead of using build
1450 in values. This makes the fit more indepedant of the underlaying
1451 rates. With a test of ~350 sequences in the test database it could
1452 be shown that the new fit gives the same result +/-1sek.
1453 The highest deviation was +5s the lowest -10s. You can now control
1454 the bahaviour with two resource values:
1455 MHEffectiveOnTime.FistBin: 3
1456 MHEffectiveOnTime.NumEvents: 12000
1457 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1458 from the resulting gamma candidates
1459
1460 - star: The Center histogram in MHHillas is now by default displayed
1461 with the colz draw-option
1462
1463 - ganymed: now produces valid error codes if failed
1464
1465 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1466 with the option "hadronness" instead of "area" or "both" if
1467 you want to use both cuts. The hadronness cut includes a fixed
1468 cut in hadronness (index 8) and a fixed cut in size (index 9).
1469
1470 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1471 the M3Long of the anti source to be not properly evaluated
1472 (actually is was evaluated as a unique random number) in case
1473 of optimization with anti-theta cut switched on. This might have
1474 lead to improper, but not necessarily wrong, optimization results.
1475
1476 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1477 how to use random forest
1478
1479 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1480 ganymed_onoff.rc. Seems to be unintentional that they were different.
1481
1482 - sponde: Since the introduction of the possibility to define a
1483 normalization energy instead of using the integral the default
1484 was not using the integral anymore but a normalization energy of
1485 1GeV. It is now the integral again.
1486
1487 - sponde: Fixed a problem in the weighting which did not allow
1488 a MC slope of -1.
1489
1490
1491
1492 *** Version 0.9.6 (2006/05/24)
1493
1494 - general: changed the binning of the azimuthal profile of the camera
1495 such that it is aligned with the 60deg boundaries.
1496
1497 - merpp: better handling of problems with the TH, TD part of the
1498 CC-REPORT for files older than 200507190 and 200412210
1499 respectively
1500
1501 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1502
1503 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1504
1505 - callisto: if an arrival time is extracted outside the fadc range is
1506 was set to the boundary before. Now a random number is assigned
1507 instead to avoid unfortunate coincidences of arrival times just
1508 by this arbitrary value.
1509
1510 - callisto: added a new option to callisto.rc which allows
1511 to set the maximum arrival time difference allowed for the
1512 badpixel algorithm to determin whether a pixels belongs to a shower:
1513 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1514
1515 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1516 to 0.9 as suggested by Stefan due to a recent study on the fraction
1517 of pixels surviving the image cleaning
1518
1519 - callisto: switched off error in case of "pulse is too much to the left"
1520
1521 - callisto: The extraction window is not adapted anymore. This means that
1522 the pulse is extracted from the full range. The draw-back is that the
1523 background (pedestal) will become slightly higher. Switching on/off
1524 the PulsePosCheck in the callisto.rc only effects filling the
1525 histograms.
1526 WARNING: If the pulse is too much to the left data is calibrated!
1527 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1528 in the database to make sure that your data is valid!
1529
1530 - star: Show also the number of stars correlated correctly by the
1531 starguider
1532
1533 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1534 than one off-source region in wobble-mode. To use it add the following to
1535 your ganymed_wobble.rc:
1536 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1537 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1538 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1539 + Cut1.ThetaCut: None
1540 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1541
1542 - ganymed: in the case the latest report is older than a default (currently
1543 one minute) and the current report will be skip the starguider
1544 correction and calibration will be reset. The maximum age can be
1545 setup from ganymed.rc by (minutes):
1546 MPointingDevCalc.MaxAge: 1.5
1547
1548 - ganymed: A first implementation showing all size-bins for the theta-sq
1549 resp. alpha-plots in a single tab automatically
1550
1551
1552
1553 *** Version 0.9.5.1 (2006/05/05)
1554
1555 - general: Added a new option "zdiff" to the Makefile which runs
1556 "cvs diff" as "make diff" would do, but with compression
1557
1558 - general: accelerated MTFillMatrix (used for eample in all training
1559 and optimization macros) by skipping some obsolete calles in the
1560 eventloop the first and second loop could be accelerated by ~20%
1561
1562 - general: Added a missing feature in the MFilterList class which
1563 prevented MFEnergySlope from working correctly in trainenergy.C
1564
1565 - general: Accelerated the random forest training and usage a bit
1566
1567 - merpp: Adapted to new raw data file format version 6
1568
1569 - merpp: fixed a problem with reading the starguider reports
1570 after 6.3.2006
1571
1572 - callisto: At some times six pixels had to be exchanged manually in the
1573 data. If the pixels to be swaped are both not found, an error was raised
1574 and calibration was stopped. Now it is assumed they are intentially not
1575 mapped and the Error has been changed to a Warning.
1576
1577 - star: Added new image cleaning based on the arrival time of the shower.
1578 The new cleaning can be accessed using the parameter "Time" instead of
1579 the the old one (like "Absolute) in the star.rc-file.
1580 Recommended parameters:
1581 + MImgCleanStd.CleanLevel1: 8.2
1582 + MImgCleanStd.CleanLevel2: 5
1583 + MImgCleanStd.CleanRings: 2
1584 + MImgCleanStd.KeepSinglePixels: No
1585
1586 - star: Simplified the calculation of the effective on time. By letting
1587 the fit start in the third bin the result should become more stable.
1588 The fit quality is now ignored for the theta-plot which is not used
1589 in the analysis later. Still better pre-cut which, for example,
1590 remove events triggered by car-light (rate changing on a short
1591 time-scale) are missing.
1592
1593 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1594 for optimization (kWeakSource) which is suggested by the Berlin
1595 people for weak sources.
1596
1597 - macros: plotdb.C:
1598 + if no dataset and no time-interval is given only sequences with
1599 an effective on-time above five minutes are plotted anymore
1600 + added a new tab "RelTime" displaying the relative on-time
1601 (effective on-time divided by the observation time)
1602
1603 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1604 the optimization became a lot faster
1605
1606 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1607 To display them just delete the pads displayed on top.
1608
1609 - ganymed: fixed a bug which could cause strange behaviour in wobble
1610 mode if no starguider information was available due to an incorrect
1611 initialization of the starguider calibration
1612
1613 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1614 be changed from within the plot. It can also be setup from the
1615 resource file using:
1616 + MHDisp.fScaleMin: 0.325
1617 + MHDisp.fScaleMax: 0.475
1618
1619 - ganymed, showplot: Fixed a problem with the fit to the off-data
1620 (HistOff) which could cause a time lag or an inifinite loop.
1621 The bug did not effect the results at all.
1622
1623 - sponde: Added a new tab showing the effective collection area after
1624 trigger (including the software trigger)
1625
1626 - sponde: MMcSpectrumWeight has a new option which allows to define
1627 the scaling factor not by the integral of the events but at
1628 a defined energy:
1629 e.g. MMcSpectrumWeight.NormEnergy: 200
1630
1631 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1632 eventloops the loop could be accelerated by ~20%
1633
1634
1635
1636 *** Version 0.9.5 (2006/03/13)
1637
1638 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1639 and added the standard Disp-parametrization
1640
1641 - macros: added a new macro datacenter/macros/plotstat.C allowing
1642 to plot statistics about the data processing
1643
1644 - macros: added a new macro to plot the muon correction coefficients
1645 versus period (macros/plot/mucal.C)
1646
1647 - showplot: path inflation for ganymed files was broken
1648
1649 - callisto: Fixed an important bug. When the number of saturating pixels
1650 were calculated the bad pixel information already available from the
1651 calibration was ignored. This yields wrong values in case pixels
1652 are broken and saturate all the time or randomly.
1653
1654 - callisto: Updated Muon calibration constants. Spline data now also uses
1655 different values for different periods
1656
1657 - star: The time-evolution shown in the effective on-time plot now displays
1658 the axis range (if there are no holes it should be similar to the
1659 effective on-time)
1660
1661 - star: Added two new image parameters:
1662 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1663 the three pixels next to the center of gravity and the size
1664 + MNewImagePar.fConcCore: The ratio of the signals of all
1665 pixels inside or touching the ellipse and the size
1666
1667 - ganymed: now stops in requested source isn't found in catalog file
1668
1669 - ganymed: Many improvements to the phi-plot in wobble mode:
1670 + with a template the ideal background is displayed
1671 + a possible camera inhomogeneity is taken into account
1672 + the anti theta cut is better supported
1673 + the phi cut is automatically calculated from the theta cut
1674 See the examples in ganymed_wobble.rc for more details.
1675
1676 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1677 times the bin-width instead of the absolute energy
1678
1679 - ganymed: New cuts for on/off and wobble mode
1680
1681 - ganymed: The smearing of the False Source plot has been increased
1682 to 0.06
1683
1684 - ganymed: The starguider calibration can now be changed from the
1685 resource file.
1686 See the examples in ganymed*.rc for more details.
1687
1688 - ganymed: added a new option for on-/off-observations
1689 MJCut.RandomSourcePosition
1690 If switched on the distribution of observation time of the source
1691 position in the camera is calculated from the on-data and randomly
1692 applied with this distrbution to the off-data.
1693
1694 - ganymed: by skipping some obsolete calles in the eventloop the
1695 first and second loop could be accelerated by ~20%
1696
1697 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1698 position in the off-data randomly according to its distribution in the
1699 on-data.
1700
1701
1702
1703 *** Version 0.9.4.3 (2006/02/13)
1704
1705 - general: Fixed a bug in most of the programs which prevented the
1706 compile date in the startup message to be displayed
1707
1708 - general: Simplified program calls. The following abbreviations
1709 are now possible:
1710 showlog callisto 55599
1711 showplot signal 55599
1712 star 55599
1713 callisto 55999
1714 ganymed 2
1715 In this cases the corrsponding root-, log-, sequence- or dataset-
1716 filename is automatically compiled using the default datacenter
1717 paths ("/magic/*")
1718
1719 - general: Fixed a long outstanding bug which made axis tick marks
1720 disappear if MDataFormula was used (eg. abs(x))
1721
1722 - general: Updated MMath with new functions to calculate the results of
1723 a exponential, logarithmic and powerlaw fits analytically.
1724
1725 - general: Updated some macros with comments:
1726 + macros/optim/optimdisp.C
1727 + macros/optim/optimenergy.C
1728 + macros/optim/optimwobble.C:
1729
1730 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1731 files) now allows adding a pre-cut like in the optimization. E.g. this
1732 is useful to perform g/h-separation cuts before training the random
1733 forest.
1734
1735 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1736 correctly assigned in the raw data assignement table. A fix to correct
1737 the assignment tabel have been implemented.
1738
1739 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1740 by 90, 180 and 270 deg.
1741
1742 - general: the macro plotdb.C now allows to highlight sequences belonging
1743 to a datset. For more details see the descritions in the macro.
1744
1745 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1746 of the display, it gave wrong results espacially for big sizes.
1747 Now the embedded canvas should always have a ratio width/height=3/2.
1748 The "Size" options have been updated with values fitting the 3/2
1749 size ratio.
1750
1751 - RanForest:
1752 + Updated the random forest classes to support also the
1753 regression method implemented by Thomas H.
1754 + added new tutorial macro how to train the random forest
1755 for energy estimation (macros/optim/rfenergyest.C)
1756 + new classes to train the random forest (still in development)
1757 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1758 + new tutorial macros for random forest training in macros/train
1759 trainenergy.C, traindisp.C, trainseparation.C
1760
1761 - mars: now allows to setup a cut in the resource file mars.rc to choose
1762 the events to be displayed, eg:
1763 Cut.Condition: {0} && {1}
1764 Cut.0: MHillas.fSize>100
1765 Cut.1: MHillas.fSize<900
1766
1767 - merpp: Made aware of the new .rep format 200510250. This includes
1768 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1769 the discriminator thresholds (MCameraTD) and the disciminator
1770 delays (MCameraTD). All of them come with the CC report and are therefor
1771 written to the CC tree.
1772
1773 - callisto: fixed a bug in the calculation of the arrival times in
1774 the Digital Filter. They were all shifted by the same amount
1775 fHiGainFirst. This caused an offset in the order of the position of
1776 the left border of the extraction window in the times calculated
1777 from high-gain and from low-gain. The bug effected only the absolute
1778 arrival times. The bug was there since 30.1.2005.
1779
1780 - callisto: Changed the ExtractionWindow for the pulse position check
1781 such that the camera inhomogeneity becomes as less as possible and
1782 comparable to the pulso position check switched off. More details
1783 on the study will be given at our result web-page.
1784
1785 - ganymed: ganymed.rc, ganymed_onoff.rc:
1786 changed to new cuts trained with 1ES1218 and Crab-data
1787 for maximum sigma*log10(excess)
1788
1789 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1790 a new option was implemented to estimate Disp (CalcDisp)
1791
1792 - ganymed: Implemented two new options which allow
1793 to overwrite the default path to search for the sequence files
1794 --ins=/magic/sequences
1795 and where to search for the image data
1796 --ind=/magic/data/star
1797
1798 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1799 dx/dy from the resource file by
1800 MSrcPosCorrect.Dx
1801 MSrcPosCorrect.Dy
1802
1803 - ganymed: fixed reading the source catalog. Only as many chars
1804 as the requested source name had were compared (If a source
1805 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1806 were requested it could happen that the coordinates of
1807 "1ES1218" were read) The source coordinates are now printed
1808 in addition to its name to the logging output.
1809
1810 - ganymed: changed the background fit in the case of a ThetaSq function
1811 from a polynomial to a exponential, this should give a big improvement
1812 for on-only analysis'
1813
1814 - ganymed/sponde: Calculation of the error of single size-/energy-
1815 bins now uses Li/Ma (5) instead of LiMa (17)
1816
1817 - sponde: Added a plot E^2*dN/dE
1818
1819 - sponde: The energy estimator plot should now show values like
1820 they are commonly used.
1821
1822 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1823 (a powerlaw with cutoff didn't work before)
1824
1825
1826
1827 *** Version 0.9.4.2 (2005/10/01)
1828
1829 - general: added new tutorial macro macros/tutorials/threshold.C:
1830 how to calculate the threshold
1831
1832 - general: added a new game. Start it from the interpreter with
1833 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1834 and MagicReversi)
1835
1836 - general: neighbor pixels in MGeoms are now sorted clockwise
1837
1838 - merpp: made aware of new format 20050829-0
1839
1840 - callisto: New scale factors from muon analysis, stored in new
1841 resource file resources/calibration.rc
1842
1843 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1844 the eventloop if something went wrong. This is necessary for the
1845 automatic processing
1846
1847 - callisto: Implemented a new treatment for the time information
1848 developed by S.Ruegamer, this should give much better response than
1849 the old very primitive algorithm. This is especially important
1850 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1851 treatment was buggy! As neighbor pixels to interpolate the
1852 arrival times always the pixels 0 to 5 were taken)
1853
1854 - callisto: In addition to the new treatment of arrival times the
1855 decision of the treatment whether a pixel contains shower
1856 information or not is used to improve the signal interpolation
1857 further. Previously interpolated pixels showed a non-zero signal
1858 do the peak searching signal extractors. Having a signal pixel
1859 beside raised the signal above the cleaning level. Thus the
1860 pixel survived cleaning to often but with a too low mean signal.
1861 By replacing empty pixels with a gaus (mean and rms from the
1862 corresponding Area entries in MPedPhotCam) this effect can
1863 be supressed.
1864
1865 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1866 got lost when the events were stored by the calibration... fixed.
1867 (This was no problem for normal image cleaning because the pixel
1868 content was artificially set to 0 not surviving standard cleaning
1869 algorithm)
1870
1871 - callisto: Fixed a bug which caused the random and peak-search pedestal
1872 extracted with an extractor to be exchanged for the first (roughly)
1873 500 events (*Extractor and *ExtractorRndm).
1874 (They were simply exchanged in callisto.cc) This bug might have been
1875 introduced in Mars 0.9.4 when the order of calculation of the two
1876 types of pedestal in callisto got exchanged. The bug only effects
1877 the first seconds of data of each sequence.
1878
1879 - star: Taking the arrival time of Muons into account the calculation
1880 of the parameters could be made independant of the noise
1881 (pedestal rms). The dependance was due to the bias of the peak search
1882 extractor. Now only a ZA dependamcy is left which is not yet fully
1883 understood.
1884
1885 - ganymed: The sequences were still not sorted correctly in any case,
1886 because they were sorted by the full qualified path name. Now they
1887 are sorted by their sequence number.
1888
1889 - ganymed: new values for the spark-event-cut
1890
1891 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1892
1893
1894
1895 *** Version 0.9.4.1 (2005/08/18)
1896
1897 - callisto: fixed some problems with the calibration in case of
1898 inteleaved events. Therefor the final and some intermediate
1899 fits are skipped which would take place on partly filled #
1900 histograms and gave wrong results or failed completely.
1901
1902 - callisto: If the intermediate finalization of the histograms
1903 calculating the mean charge of the calibration signal fails
1904 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1905
1906 - ganymed: Fixed some bugs which caused problems in On-only mode.
1907 Still the false source plot doesn't give reasonable results.
1908
1909
1910
1911 *** Version 0.9.4 (2005/08/05)
1912
1913 - general: Fixed the ZA binning. It did not correctly fit the
1914 MC binning
1915
1916 - general: Added a class to correct for the missfocussing in
1917 April (MSrcPosCorrect)
1918
1919 - general: Random Forest energy estimator should now work properly
1920
1921 - general: MHCamera now displays the profiles in deg instead of mm
1922
1923 - general: MH::SetPalette offers a lot of new palettes
1924
1925 - general: MHillas - the case of CorrXY==0 is now handled properly
1926
1927 - general: implemented the possibility to change the line and
1928 marker style of a sky-grid drawn by MAstroCatalog
1929
1930 - general: Runs in sequences and datasets are now automatically
1931 ordered (it is assumed that the order of their filenames correctly
1932 represents the order of observations) to ensure correct reading
1933 of the subsystem data
1934
1935 - general: Runs cannot be added to a sequence twice anymore. Also
1936 Sequences cannot be added twice anymore to a dataset.
1937
1938 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1939 It gave wrong results by 1./2pi
1940
1941 - showplot: got a new option to start a root interpreter, too
1942
1943 - mars: now displays a rough estimate of Disp and the third moment
1944
1945 - mars: now displays the event time MTime if available
1946
1947 - mars: show muon parameters graphically
1948
1949 - mars: now the file to open can be given as commandline
1950 argument
1951
1952 - merpp: Added support for new arehucas version >= 200507190
1953 implementing values for three temperature sensors in the
1954 counting house (MCameraAUX) and the name of the HV settings file
1955 (MCameraHV).
1956
1957 - merrp: Also fixed some problems with wrong versions numbers stated
1958 by arehucas and implemented some fixed for old versions (<200407070)
1959
1960 - callisto: MCalibrationHiLoCam can now be printed from its context
1961 menu, eg in the TBrowser
1962
1963 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1964 - 1.39 (MExtractTimeAndChargeSpline)
1965 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1966 This is important mainly for timing studies.
1967
1968 - callisto: Changed limits in MHCalibrationChargeCalc from
1969 - -100.125 to -98 (fgChargeHiGainFirst)
1970 - 1899.875 to 1902. (fgChargeHiGainLast)
1971 - -100.25 to -99 (fgChargeLoGainFirst)
1972 - 899.75 to 901. (fgChargeLoGainLast)
1973 Introduced new limits:
1974 - fgNumLoGainBlackoutLimit: 0.05
1975 - fgLoGainBlackoutLimit: 3.5
1976 - fgLoGainPickupLimit: 3.5
1977
1978 - callisto: The handling of automatic weights for the digital filter
1979 has been improved. There are now new calibration weights special
1980 for Monte Carlo calibrations.
1981
1982 - callisto: Updated Muon scale with latest results (1% difference
1983 for most data, 5% for Mar/Apr'05)
1984
1985 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1986 was saturated and the blackout-events in the low-gain exceed the
1987 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1988 This excludes those pixels which have a saturating high-gain
1989 channel, but the low-gain switch does not switch often enough
1990 to make the distribution reliable.
1991
1992 - callisto: fix a bug counting the number of saturated events. Up to now,
1993 the number of saturated slices was counted (which is one for a not too
1994 high number), but for some (pathological) pixels, many more slices
1995 saturated and produced wrong limits.
1996
1997 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1998 + MCalibrationRelTimeCam.CheckFitResults: Yes
1999 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2000 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2001 + MCalibrationRelTimeCam.CheckOscillations: Yes
2002
2003 - callisto: introduce max. number of events for intercalibration,
2004 the rest gets skipped. Default: 4096
2005 The calibration causes too many un-reliable pixels if more
2006 than about 5000 events are treated (@500 Hz) because of the
2007 mode hopping of the VCSels. However, in the past, some
2008 calibration runs have been taken (erroneously) with more
2009 than 5000 events, especially the intensity scans where
2010 a good precision is needed.
2011
2012 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2013 photo-electrons for the spline extractor by 1-2% (correctly).
2014
2015 - callisto: The intercalibration is now done using a full f-factor
2016 method instead of a simple update. This makes things slower but
2017 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2018 changes.
2019
2020 - callisto: MPedestalY3 now uses the same extraction range as the data
2021 as calculated by MPedestalY2
2022
2023 - callisto: A check of the fraction of allowed unsuitable (10%) and
2024 unreliable (30%) pixels has been addded when the conversion is
2025 calculated from interleaved events
2026
2027 - star: fixed a bug which caused MEffectiveOnTime containers not to
2028 be written. In the worst case they were skipped almost all, in the
2029 best case they were all ok. It depends on how often the new value
2030 was assigned just with an event which was skipped later by another
2031 task
2032
2033 - star: new histograms MHPointing and MHRate
2034
2035 - star: New tab (Currents) displaying the time evolution of the mean
2036 DC currents
2037
2038 - star: New tab (MeanRms) displaying the time volution of the mean
2039 Pedestal Rms
2040
2041 - star: Output now contains MReportStarguider
2042
2043 - star: Improved muon analysis. Due to the absense of a constant
2044 for the gaus fit for arc width and the fact that the arcwidth
2045 plot was a histogram instead of a profile the resulting psf
2046 became pedestal rms dependant
2047
2048 - ganymed: added new plot (MHPhi) for wobble mode as described in
2049 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2050
2051 - ganymed: corrects now (correctly?) for the misspointing in
2052 May/April 05
2053
2054 - ganymed: Two new default templates for ganymed.rc are avilable:
2055 ganymed_onoff.rc and ganymed_wobble.rc
2056
2057 - ganymed: The first version of MFMagicCuts has been released
2058
2059 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2060
2061 - ganymed, sponde: There are two new options to determin the number
2062 of bins for the signal region (NumBinsSignal) and the number of
2063 total bins (NumBinsTotal) in the MHThetaSq histogram
2064
2065 - ganymed: optimized palettes for MHDisp
2066
2067 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2068 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2069 sqrt(2) to large
2070
2071 - ganymed: The false source plot (MHDisp) is now based on Disp
2072 and a background model determined in the first loop is
2073 subtracted
2074
2075 - ganymed: MFMagicCuts are now available in the cvs. The correct
2076 solution for the disp ambiguity problem is now calculated using
2077 the third moment. The third moment cut therefor is skipped.
2078
2079 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2080 already determined by the third moment along the major axis and
2081 so its actual sign is aligned along the major axis of the shower.
2082
2083 - ganymed: If starguider data is available it is taken into account
2084 when calculating the source position. This is especially important
2085 for wobble data at high zenith angles and culmination data.
2086
2087 - ganymed: If available the starguider data is taken into account as
2088 good as it is possible without a starguider calibration. To switch
2089 it off add
2090 MPointingDevCalc.MaxAbsDev: -1
2091 to your ganymed.rc
2092
2093 - sponde: the zenith angle distribution is now weighted instead of
2094 choosen by default. This gurantees higher statistics in the highest
2095 and lowest energy bins. To switch this behaviour off use...
2096
2097 - sponde: now automatically displays the energy threshold
2098
2099
2100
2101 *** Version 0.9.3 (2005/06/03)
2102
2103 - general: MMcEvt now derived from MMcEvtBasic which should
2104 have no influence on compatibility with older camera files
2105
2106 - general: Implemented a new option to MReadReports which allows
2107 to force reading of the first event of some trees (eg. Drive-tree)
2108 before any other tree.
2109
2110 - general: Made a fix to MPointingPosCalc which assumes that the
2111 run-type is real-data if Process is called before ReInit, such
2112 that also the very first Drive-events in a run are treated
2113 correctly.
2114
2115 - shoplot now displays the filename in the title bar of the window
2116
2117 - merpp: new options: --auto-time-start --auto-time-stop which
2118 allow to cut updating with slow-control at the start- or
2119 (previousle --auto-time only allowed: and) stop-time of
2120 the run stored in the runheader.
2121
2122 - callisto: changed default of fgFallTimeHiGain in
2123 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2124 already set as default in callisto_Dec04Jan05.rc
2125
2126 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2127 now changes the filename for new weights automatically for
2128 cosmics, MC and for different calibration colors.
2129
2130 - callisto: a problem with the order of some code cause the
2131 name of the weights file in MPedestalY2 to be ignored.
2132 Wrongly the calibration_UV weights were used instead
2133 of the cosmics weights set in callisto.rc.
2134
2135 - callisto: should allow ct1 pulser data when the color is
2136 explicitly set also for pretty new runs
2137
2138 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2139 to introduce an additional scale factor (should be around 1)
2140 to adapt for slight deviations in different extractors from
2141 the MC calibration. For MC calibrations the scale factor
2142 is fixed to 1
2143
2144 - callisto: MFCosmics should handle very high signals a bit
2145 more accurate now
2146
2147 - callisto: when calculating the mean pedestal rms for different
2148 pixel sizes or sectors also kUnsuitableEvt is now taken into
2149 account - not only kUnsuitableRun
2150
2151 - callisto: '-raw' option is now the default
2152
2153 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2154 This has the advantage that mean values in the calibration (eg
2155 arrival times) are calculated more accuratly.
2156
2157 - callisto: In the resource file callisto_Dec04Jan05.rc
2158 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2159
2160 - callisto: new Hi-/Lo-Gain intercalibration constants
2161 hilocalib_sp1.root and hilocalib_sp1_mc.root
2162
2163 - callisto: changed default for MJPedestalY2.MaxEvents
2164 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2165
2166 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2167 has changed from 9.0 to 6.0. This is necessary to exclude two very
2168 ringing pixels in September which - when kept - destroy the image
2169 cleaning around them (Markus G.)
2170
2171 - callisto: (!) The Muon analysis of all data taken so far has
2172 suggested that different extractors give slightly different
2173 absolute results after calibration, due to there different
2174 handling of the calibration- and cosmics pulse shape. Although
2175 the over all calibration seems to be a bit to pesimistic (or
2176 the MC seems to be a little bit - 3-5% - too much attenuated).
2177 There for correction factors have been introduced which correct
2178 the calibration constants by
2179 0.956937799 for Digital Filter (callisto.rc)
2180 and
2181 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2182 calibration. The main advantage is, that both data types can
2183 be easily analysed together and compared to the same MC sample.
2184 The factors are choosen such, that the reference is now a
2185 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2186
2187 - star: fixed a bug which caused the first bin of the histograms
2188 vs time to disapear in PostProcess. This gave wrong results
2189 on the screen. The output and all following programs not
2190 directly accessing the histograms haven't been affected
2191
2192 - star, ganymed: Made sure that always the first Drive-tree event
2193 is read and Processed before the first data event was read.
2194
2195 - ganymed: implemented the possibility to replace the standard
2196 false source plot with a different one. For example: If
2197 you want to use a Disp based FS plot use the resource:
2198 NameHistFS: MHDisp
2199 For details about the requirements of these plots look
2200 at the corresponding classes
2201
2202 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2203 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2204 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2205 case MAlphaFitter is setup correctly. For On-Only optimization
2206 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2207 RunOn() instead of Run(). For energy estimation MJOptimize
2208 has been replaced by MJOptimizeEnergy
2209
2210 - sponde: The input MC spectrum can now be weighted to fake a
2211 different spectrum. This is done via MMcSpectrumWeight. For
2212 more details see the class description and sponde.rc
2213
2214 - sponde: The paremeter comparsion plots are not scaled by
2215 their entries anymore. Instead the MC plot is scaled by using
2216 the result spectrum of the analysis. If the input MC spectrum
2217 and the result spectrum has different slopes the absolut
2218 normalization is normally wrong.
2219
2220
2221
2222 *** Version 0.9.2 (2005/05/20)
2223
2224 - general: Changed the default paths for calibrated data and image
2225 files. (The implemented access to these files doesn't yet exist)
2226
2227 - general: support for MRunIter has been removed from the job classes
2228 (use the setter functions of MSeqeunce instead)
2229
2230 - general: ProcessFile has been renamed to Process in all job classes,
2231 because ProcessFile is missleading
2232
2233 - general: The storage of the palette in MHCamera is now possible
2234
2235 - general: new bits describing unsuitable and unreliable pixels have
2236 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2237 kDeadPedestalRms, kFluctuatingArrivalTimes
2238
2239 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2240 versions newer than V200404070
2241
2242 - general: support for cc file versions newer than V200504130. Added
2243 support for active loads (MCameraActiveLoad) and central pixel
2244 (MCameraCentralPixel)
2245
2246 - general: added new histograms for image parameters versus size
2247 (MHVsSize)
2248
2249 - general: The eventloop now automatically calls PrintStatistics
2250
2251 - Status Display: Improved support for printing:
2252 + A default can now be set in .rootrc (for more details see
2253 MStatusDisplay::PrintPS)
2254 + A print dialog is opened so that printer and command line
2255 can be canged
2256
2257 - showlog: improved such that it handles different verbosity levels
2258 more accurate now. This mean you can suppress output when
2259 using showlog.
2260
2261 - showplot: improved
2262 + The new graphics formats have been implemented
2263 (pdf, svg, png, jpg and xpm)
2264 + Implemented an interface for printing. Because you can change
2265 the printing command from the command line you can use all
2266 the nice postscript tool. To print a booklet for example call:
2267 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2268 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2269 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2270
2271 - callisto: fixed a bug in the recognition of the calibration bit
2272 pattern. Concerns only intensity calibration. (The strength of the
2273 intensity has been updated in some cases)
2274
2275 - callisto: add a filter against PIN Diode events when running over
2276 calibration runs since some of the recent calibration runs have
2277 been taken with Pin Diode.
2278
2279 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2280 39943, 44833 in the calibration (MCalibColorSet)
2281
2282 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2283 been set to 1e-18 in callisto_Dec04_Jan05.rc
2284
2285 - callisto: in callisto_Dec04Jan05.rc: set value for
2286 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2287 statistics for the calculation of the mean pulse time
2288 of the cosmisc
2289
2290 - callisto: the charge limit in the calibration has been raised
2291 from 2.5 to 4.5
2292
2293 - callisto: new setup read from callisto.rc
2294 + MCalibCalcFromPast.fNumEventsDump
2295 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2296 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2297
2298 - callisto: MExtractTimeAndChargeSpline extractor:
2299 + The integration ranges were shifted by 0.2 FADC slices to the right.
2300 + unreliable handling of floating point values caused different
2301 results on different platform or with different compiler options:
2302 The new algorithm is numerically exact and more accurate because
2303 it doesn't calculate the integration position by multiple times
2304 adding the step-size (which results in numerical uncertanties
2305 exspecially if multiplied with large numbers)
2306 + A lot of fixes have been introduced which effects integrating the
2307 spline at the edges of the valid range. In this case any memory
2308 was randomly accessed. This behaviour can be tested replacing
2309 all MArrayF by TArrayF which perform a range check (but of course
2310 they are a lot slower)
2311 ! No result obtained with the Spline before can be trusted! Due to
2312 random memory access it might by completely random!
2313
2314 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2315 + extraction range in the high gain to 4.
2316 + weights file to cosmics_weights46.dat
2317
2318 - callisto:
2319 + introduce the check for fluctuating arrival times.
2320 + set charge limit to from 2.5 to 4.5
2321 + introduce asymmetric exclusion due to "deviating number of phes":
2322 Default: -9.0 +4.5
2323 + make deviating number of phes unsuitable (see David's findings).
2324
2325 - callisto: fixed the display of unsuitable pixels. The old change
2326 to a real profile in MHCamera broke it.
2327
2328 - callisto: The cosmics filter is used in MJCalibration now
2329 independant of the pulser color (formaly it was used only for
2330 CT1-pulser data). The threshold of number of max empty pixels
2331 has been raised from 2% to 5% in MJCalibration. The maximum
2332 fraction of rejected event is 50% otherwise the calibration has
2333 failed. The filter now ignores unsuitable pixels.
2334 Setup the filter from callisto.rc using "ContCosmics"
2335 (see MFCosmics::ReadEnv)
2336
2337 - callisto: changed default for fgOffsetFromLogain back
2338 from -2.8 to -1.8 in digital filter.
2339
2340 - callisto: for the common extractors
2341 + MExtractFixedWindow
2342 * MExtractTimeAndChargeSlidingWindow
2343 * MExtractTimeAndChargeSpline
2344 * MExtractTimeAndChargeDigitalFilter
2345 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2346 and fResolutionPerPheLoGain
2347
2348 - callisto: Updated the hi-/lo-gain intercalibration constants
2349 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2350 hilocalib_df6.root
2351
2352 - callisto: The default lo-gain extraction window for the
2353 MExtractTimeAndChargeSlidingWindow extractor has been increased
2354 from 6 to 8 to take the stretch of the pusle into account
2355
2356 - callisto (!!!): fixed an important bug in the setting of the
2357 incoming pedestal pointer to the signal extractor extracting
2358 pedestals. This bug caused the pedestals not to be subtracted
2359 correctly in the calibration afterwards. The effect was about 10%
2360 too high conversion factors for the digital filter and the spline
2361 and more than 40% for the sliding window.
2362 The bug existed since end of February! (Markus G.)
2363
2364 - star: added muon support to star. A new tab "MHMuonPar" is
2365 displayed. The lower right plot is an estimate of the point spread
2366 function. A reference value is displayed. To get the real PSF
2367 you must compare with MC. The setup for the muon analysis
2368 is done in star.rc. More informations can be found in
2369 MHSingleMuon and MHCalibParCalc
2370
2371 - star: The weather data is now displayed in star
2372
2373 - star: MEventRateCalc handles the calculation of the event rate more
2374 accurate now in case of the start of a new run inside a sequence
2375
2376 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2377 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2378 changed only minimally
2379
2380 - ganymed: (MJCut and MJOptimize) now displayes the number of
2381 excess events versus size. The energy estimation is done in
2382 MJSpectrum (sponde)
2383
2384 - ganymed: got support for using other variables than Alpha, eg. Theta.
2385 Therefor you need a class deriving from MHAlpha which supports
2386 this variable (one is already existing: MHTheta, which is now the
2387 default in ganymed). It is setup through ganymed.rc
2388
2389 - added a full featured spectrum program (sponde) which reads
2390 ganymed output and monte carlos and compiles a spectrum
2391
2392
2393
2394 *** Version 0.9.1 (2005/04/14)
2395
2396 - Fix bug on the arrival time reconstruction when using Digital
2397 Filter (in some marginal cases (10%) times were reconstructed shifted
2398 by 0.2 slices)
2399
2400 - all executables now return 2 where in previous versions -1 has
2401 been returned (gave problems with shell-scripts)
2402
2403 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2404 also done with a intercalibration input file
2405
2406 - a bug in the time fine adjustment of the digital filter has been fixed
2407
2408 - a lot of small fixes to calling TPad::Divide with a margin==0
2409
2410 - MStatusDisplay now shows the memory usage
2411
2412 - added a memory leak statistic after the eventloop
2413
2414 - MHadronness replaced by MParameterD
2415
2416 - MEnergyEst replaced by MParameterD
2417
2418 - wobble mode can now be switched on from the data-set
2419
2420 - switched on bad pixel detection for a pedestal level
2421 which is more than 5 times the variance
2422
2423 - Fixed default paths to be correct for the new data center
2424
2425 - Fixed handling of drive data. The pointing position in now
2426 copied to MPointingPos inside star for real and MC events
2427
2428 - made sure, that the sequences in a dataset are sorted by
2429 their number to ensure the correct synchronization
2430
2431 - added all resource files necessary to handle spline extraction
2432 of signal for the late 2004 and the early 2005 data
2433
2434 - update the reference lines for the december data
2435
2436 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2437 This is important for the Dec. and Jan. data where the calibration
2438 pulse position changes much.
2439
2440 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2441 filter. This corrects only an defective extraction of the MC at
2442 low-gain signals lower than 90 phes.
2443
2444 - fixed some slowdown in calibrating data with interleaved events from
2445 Jan and Dec. As a workaround made the pretty palette the default.
2446 The inverse Deep Blue Sea has a bug which slows down long calibration
2447 runs a lot.
2448
2449 - implemented new values from new starguider report as defined
2450 in TDAS00-07 V7.1 (eg SkyBrighness)
2451
2452 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2453 in starguider report (If you merpp the same reports with this version
2454 you'll get the correct units (arcmin) but a different result
2455 than with old versions (wrong units))
2456
2457 - Now the status display can also write PNG, JPEG and XPM (other file
2458 formats are still unsupported by root)
2459
2460 - added a lot of scripts and macros in directory datacenter used
2461 for automatic processing
2462
2463
2464
2465 *** Version 0.9 (2005/03/23)
2466
2467 - Calibration is now done autmatically into photo-electrons like
2468 decided by the Collaboration Board
2469
2470 - Reference lines in the display can be read from resource file
2471
2472 - Interlaced calibration events can be handled by callisto
2473
2474 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2475 and applied in callisto.
2476
2477 - class MJCalibTest can be called by callisto
2478
2479 - callisto can now run with three data types: rawdata, rootdata, MC
2480
2481 - added two classes mreport/MReportStarguider.cc and
2482 mreport/MReportStarguider.h for implementing starguider-data
2483
2484 - the output of merpp-update now contains starguider information:
2485 MReportStarguider and MTimeStarguider
2486
2487 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2488 values were lower than they should. This was more visible for high
2489 energy (Size) events.
2490
2491 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2492
2493 - added a new loop to callisto to support the correct extraction of
2494 the pedestal and pedestal rms through the signal extractor
2495
2496 - added class to perform fourier tranformation of a hexagonal structure
2497 (MHexagonalFT)
2498
2499 - added class to perform fourier tranformation of a hexagonal structure
2500 in a tasklist (MHexagonalFTCalc) example: hft.C
2501
2502 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2503 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2504 small pixels, example: extendcam.C
2505
2506 - added possibility to write data to memory (TTree) using MWriteRootFile
2507
2508 - added possibility to read a TTree stored only in memory by MReadTree
2509
2510 - new classes to deal with the interleaved calibration events:
2511 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2512
2513 - implemented filters to callisto to skip calibration events
2514
2515 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2516 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2517 the slices by statistics
2518 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2519 signal extractor without randomization
2520 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2521 with the signal extractor with randomization (extraction window is
2522 randomly fixed)
2523 The three kind of pedestal is not yet implemented (for speed reasons) as
2524 long as nobody really needs it:
2525 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2526 extracted with the signal extractor with randomization
2527
2528 - callisto now finds the pulse position in the data automatically
2529
2530 - implemented data reduction in calibrated data by reducing the precision
2531 of the stored floating point values (pedestal, rms and signal) to
2532 roughly 0.5%
2533
2534 - fixed showplot to make file format conversion (eg. converting a
2535 status display stored in a root file into a postscript file) in
2536 batch mode possible:
2537 showplot -b --save-as-ps[=outfile.ps] infile.root
2538
2539 - Allow class names as part of filter rules, eg
2540 (MFSupercuts) && (MHillas.fSize>100)
2541
2542 - fixed a lot of stuff to allow all programs to process MonteCarlo
2543 camera files.
2544
2545 - enhanced possibility to debug reading of resource file
2546
2547 - MDataChain should handle priorities of operator more
2548 accurate now
2549
2550 - completely revised the container in which the signal is stored
2551 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2552 * the new implementation is faster and
2553 * needs less storage space
2554
2555 - FIRST version which can process Monte Carlos through the
2556 whole chain of programs (callisto, star, etc)
2557
2558 - implemented new image parameters for the border length of
2559 the shower image (MNewImagePar2)
2560
2561 - implemented wobble-mode in ganymed
2562
2563 - new class (MJOptimize) taking care of all optimization processes
2564
2565
2566
2567 *** Version 0.8.6 (2004/10/05)
2568
2569 - New combined signal and time extractor
2570 MExtractTimeAndChargeDigitalFilter
2571
2572 - The Report for the trigger section in the CC run summary has been
2573 updated, and now the IPRs (Individual Pixel Rates) are available.
2574
2575 - new macros for database interaction: filldotrun.C, filldotrbk.C
2576
2577 - added new program which can convert colored output which was redirected
2578 into a file back into colored text (for example to display it with
2579 more): showlog
2580
2581 - added new program to display an MStatusArray of plots (stored with
2582 MStatusDisplay) from a file: showplot
2583
2584 - Added support for Sequences (MSequence). Sequences are blocks of run
2585 files containing the same calibration and belonging to the same
2586 source
2587
2588 - Added a new task (MTaskEnv) which can be used in setup files to switch
2589 between different tasks (for example to choose a signal extractor)
2590
2591 - Implemented automatic file splitting in MWriteRootFile
2592
2593 - After image cleaning an island index is assigned to all used pixels.
2594 The index corresponds to the order of the islands in size.
2595
2596 - added a cleaning which takes signal height _and_ arrival time into
2597 account: probability cleaning (for more details see MImgCleanStd)
2598
2599 - added a cleaning which takes takes the absolute number of photons
2600 times the area ratio as cleaning level
2601 (for more details see MImgCleanStd)
2602
2603 - Changed calculation of image parameters such, that it can be done
2604 for all used pixels or the pixels with a defined island index only
2605
2606 - implemented new image parameters displaying the number of islands,
2607 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2608
2609 - event display in executable changed to support also calibrated files
2610 (done with MJCalibrateSignal)
2611
2612 - added program doing the calibration and the signal extraction
2613 and signal calibration: callisto Most part of the setup is done
2614 by a resource file: callisto.rc
2615
2616 - implemented support for pixels with negative IDs (Raw file format
2617 version 4)
2618
2619 - implemented an new option in merpp (--auto-time) to get the time
2620 range for cc and/or caco data from the run header of the raw data
2621
2622 - New star-program (star and MJStar). Taking calibrated data from
2623 callisto/MJCalibrateSignal as input. The setup is done through
2624 a resource file: star.rc
2625
2626 - Added possibility to setup the eventloop in the mars-executable
2627 Camera Display by a resource file: mars.rc
2628
2629 - The the mars-executable Camera Display can now also read
2630 calibrated data files written by callisto/MJCalibrateSignal
2631
2632 - Added a new class which can calculate the source position in
2633 the camera from a pointing model known to be correct and
2634 the pointing model used for observations (MSrcPosFromModel)
2635
2636 - added a new version of the class calculating the effective on-time
2637 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2638 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2639 MHTimeDiffTheta.
2640
2641 - added the possibility to count how often a signal is above (or
2642 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2643 can replace MHTriggerLvl0)
2644
2645 - added ore convinient ways to set the axis-titles of your histograms
2646 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2647 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2648
2649
2650
2651 *** Version 0.8.5 (2004/08/06)
2652
2653 - new Signal Extractors: MExtractFixedWindowSpline
2654 and MExtractAmplitudeSpline
2655
2656 - implementes interleave in merpp to be able to merpp parts of a file
2657
2658 - implemented force-functionality to merpp
2659
2660 - star display to display star catalogs (MAstroCatalog)
2661
2662 - star display to 'mirror' stars to the camera (MAstroCamera)
2663
2664 - implemented a new cleaning option which allows cleaning scaled with
2665 the real ratio of the rms depending on the pixel size, not only the
2666 square root of the pixelsize (MImgCleanStd, MCameraData)
2667
2668 - removed obsolete MBlind* classes
2669
2670 - Signal extractor taking the AB flag into account implemented (this makes
2671 an odd number of slices for signal extraction possible
2672 (MExtractSignalABcorr)
2673
2674 - implemented a class extracting the pedestal from the raw-data (events)
2675 itself using empty lo-gain (MpedCalcFromLoGain)
2676
2677 - Added mean values to MPedPhotCam
2678
2679 - Added Makefile for Darwin (this OS is NOT officially supported!)
2680
2681
2682
2683 *** Version 0.8.4 (2004/04/19)
2684
2685 - new fast arrival time extractor using cubic splines:
2686 MExtractTimeFastSpline
2687
2688 - implementes multi-argument support in MDataChain
2689 ("pow(a, b)")
2690
2691 - implemented double reference support in MDataChain
2692 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2693
2694 - added support in MF for expressiond like
2695 "MHillas.fWidth<2*<MHillas.fLength"
2696
2697 - MDataChain is now able to support variables like [0], [1], ...
2698 which can be used in fit functions as parameters. The interface
2699 is implemented through the new virtual function
2700 MParContainer::SetVariables
2701
2702 - added new class MArrivalTimeCam/MArrivalTimePix:
2703 Storage containers to hold the ArrivalTime of the camera/pixel
2704
2705 - added new classes for the calibration of relative arrival times:
2706 MCalibrationRelTimePix and MCalibrationRelTimeCam
2707
2708 - added new classes to extract the signal of the blind pixel and the
2709 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2710
2711 - added new classes for the bad-pixels treatment (MBadPixels*)
2712 which are more powerfull than the old ones (MBlindPixel*)
2713 and will replace them.
2714
2715 - added filter against cosmics: MFCosmics
2716
2717 - added new class MArrivalTimeCalc2:
2718 Calculates the arrival time as the signal weighted mean of the time
2719 slices in the maximum window
2720
2721 - added a new macro call pointspreadfucntion.C that fits with a 2D
2722 gaussian the DC spot for an star. It gives you the RMS of
2723 the PSF and the center of the star, very useful for misspointing
2724 studies.
2725
2726 - added support for multi-telescope camera files. Added classes
2727 MStereoCalc and MStereoPar, classes to calculate and store shower
2728 parameters calculated from the data of two telescopes, for the MC
2729 studies regarding the MAGIC clone.
2730
2731 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2732 MC data calibrated in photons instead of ADC counts.
2733
2734 - added three macros to show the calibration and analysis chain of
2735 MC data. The macro starmc.C does both calibration and analysis, producing
2736 an output containing Hillas parameters for each event. The macro
2737 mccalibrate.C does just the calibration and writes out a file containing
2738 pixel information in photons instead of FADC data. The macro starmc2.C
2739 reads in such a file and produces an output with Hillas parameters.
2740
2741 - added MPedPhotCalc to compute pedestals in units of photons, see
2742 macro pedphotcalc.C
2743
2744 - added all class to perform the calibration, see macro calibration.C
2745
2746 - added class MFFT to perform Fast Fourier Transforms
2747
2748 - added class MSimulatedAnnealing to perform simulated annealing
2749 minimizations
2750
2751 - added new macro bootcampstandardanalysis.C which holds the skeleton
2752 of the analysis chain discussed in the december bootcamp.
2753
2754 - added support for DAQ raw data file format V2
2755
2756 - implemented an arbitrary time stamp for the events from raw-data
2757 files with file version<3. It is calculated from the run number,
2758 the date of start and the FADC clock tick from the first module
2759
2760 - implemented the correct decoding of the event time-stamp
2761 coming from the DAQ for raw-data files with file-version>2
2762
2763 - added a new classes storing the pedestals in units of photons:
2764 MPedPhotPix, MPedPhotCam
2765
2766 - added support for DC current files from the camera control
2767
2768 - added support for start- and stop-time when merpping report files
2769
2770 - added MReportCC storing the weather data from the CC-REPORT
2771
2772 - added class to fill trainings and test matrices (MTFillMatrix)
2773
2774 - added a filter performing a software trigger (MFSoftwareTrigger)
2775
2776 - Added classes to perform parts of the standard analysis (Jobs):
2777 + MJPedestals
2778 + MJCalibration
2779 + MJExtractSignal
2780 Note: All of them are preliminary!
2781
2782 - Added Iterator to iterate over files giving only the run-number
2783
2784 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2785 the evolution of a sector vs time
2786
2787
2788
2789 *** Version 0.8.3 (2003/12/05)
2790
2791 - adapted Random Forest classes to allow the use with MC
2792 multi-telescope files which can be produced with the coming
2793 camera version 0.7.
2794
2795 - added classes to read and interprete central control report files
2796 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2797
2798 - enhanced merpp (the executable) to support .raw and .rep files.
2799
2800 - added classes for light calibration (MCalibration* and
2801 MHCalibration*) by Markus Gaug. Further work has to be and will
2802 be done soon.
2803
2804 - Added a preliminary 'synchronizer' (MReadReports) which will
2805 replace MReadMarsFile as soon as it is finished.
2806
2807 - Added a tutorial macro demonstrating how report files are merpped
2808 and how they can be read from the root file in the correct order
2809 of time (readrep.C)
2810
2811 - Added a generalized histogram (similar to MH3) called MVsTime
2812 which allows to plot variables (or rules - MDataChain - of
2813 variables) vs time. For an example have a look at tempvstime.C.
2814
2815 - Changed the name of the event trees:
2816 + Events --> Events
2817 + PedEvents --> Pedestals
2818 + CalEvents --> Calibration
2819
2820 - changed name of MTime in the event trees from MRawEvtTime to MTime
2821
2822 - added displaying the sector indices to the mars event display
2823
2824 - Magic Online Analysis (MOnA) implemented in a first version
2825 (see mona.cc, MOnlineDump and MOnlineDisplay)
2826
2827 - added classes to calculate event rate
2828 (preliminary: MEventRateCalc, MEventRate)
2829
2830 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2831
2832 - added classes dealing with the telescope pointing position (MPointing*)
2833
2834 - implemented the 'final' Mars time stamp based on some experiences with
2835 the new 'Synchonizer'
2836
2837
2838
2839 *** Version 0.8.2 (2003/11/10)
2840
2841 - accelerated standard analysis by a factor of 6-8 ...
2842 + doing precalculations in MGeomCam for the pixel area ratio
2843 + creating a look up table for the single pixels in MCerPhotEvt
2844
2845 - added task to calculates weights in case you want to 'change'
2846 the energy spectrum of a monte carlo file
2847 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2848
2849 - added a new executable star which implements the
2850 star.C macro as precompiled executable. Currently a flexible
2851 setup is not possible, but a 'input card' setup will follow.
2852
2853 - Starting to implement Multi-Telescope-Support based on the
2854 upcomming camera version 0.7. The base for a general support
2855 is implemented and the star-functionality is proven to work.
2856
2857 - Replaced Event-Display in and Camera-Display in the Mars GUI
2858 executable by a more convinient display base on MStatusDisplay.
2859
2860 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2861
2862
2863
2864 *** Version 0.8.1 (2003/10/20)
2865
2866 - added signal subtraction for pure on data by means of fitting
2867 the background in the off region or by performing a combined
2868 signal/background fit. Provides necessary histograms for
2869 obtaining energy spectra and a light curve.
2870
2871 - added classes to perform and study the selection of the
2872 2nd Level Trigger on MC data (example in triglvl2.C macro)
2873
2874 - added pedestal calculation
2875
2876 - implemented "democratic cleaning" (tail cut value proportional
2877 to pixel area) according to Wolfgang's suggestion.
2878
2879 - added Sigmabar treatment (calculation and basic histogramming)
2880
2881 - added basic routines to apply padding
2882
2883 - added first implementation of MARS-based source visibility plotter
2884 (needs to be linked against slalib, preliminary version)
2885
2886 - enhanced functionality of data chains: random numbers, conversion
2887 functions and access to MHMatrix objects
2888
2889 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2890 numbers under certain circumstances (runs with 0 events included)
2891
2892 - fixed a bug in the general filter MF (didn't work on some systems
2893 at all)
2894
2895 - fixed a bug in chaining files, which caused the analysis to crash or
2896 ignore files
2897
2898 - implemented more geometry classes describing the parameters used
2899 to simulate the PMT camera
2900
2901 - added new Monte Carlo classes containing the setup of the different
2902 programs in the MC chain.
2903
2904 - added a (preliminary) general task to evaluate chi-square of a given
2905 parameter in an eventloop.
2906
2907 - first implementation of a container describing the observatory
2908 location (Long, Lat, etc)
2909
2910 - added Random Forest - method for g/h-separation
2911
2912 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2913 (this means, that it is compiling, but not yet fully tested)
2914
2915 - added a new status display which can show the present status
2916 of histograms while an eventloop is running (MStatusDisplay,
2917 an example can be found at status.C)
2918
2919 - reorganized directories:
2920 classes describing the image --> mimage
2921 classes containing Monte Carlo Histograms --> mhistmc
2922 classes for Random Forest method --> mranforest
2923
2924 - added (event-)weights to fill histograms
2925
2926 - colors in logging output to screen
2927
2928 - changes to the Image Parameter declaration:
2929 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2930 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2931 + MHillasExt now derives from MParContainer instead of MHillas
2932 --> Files written with the old definition are more or less unreadable
2933
2934 - reading of reflector files
2935
2936 - display data from reflector files in the camera
2937
2938 - implemented currents (and display them in the camera)
2939
2940 - logarithmic scale in camera
2941
2942 - added class to iterate through directory contents (MDirIter)
2943
2944
2945
2946 *** Version 0.8 (2002/11/18)
2947
2948 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2949
2950 - corrected 48(!) wrong entries in the Next Neighbor table of the
2951 Magic Camera (all in the inner part of the outer ring, mostly
2952 missing a single NN)
2953
2954 - Fixed a bug in the table describing the Next Neighbours of the
2955 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2956 have any neighbour)
2957
2958 - changed trigrate.C: now it calculates the pure NSB triggers from
2959 a camera file (generated with no showers), so there is no need
2960 to introduce them by hand in the BgR array (for more details
2961 please ask Abelardo)
2962
2963 - added MHHadronness (and MHadronness) as a general facility to evaluate
2964 the quality of a gamma-hadron seperation method
2965
2966 - changed MWriteAsciiFile to accept rules (MDataChain)
2967
2968 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2969 must be replaced by calles to MWriteAsciiFile::AddColumn and
2970 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2971 changed.
2972
2973 - Implemented generalized event-matrices (one row per event)
2974 (MHMatrix)
2975
2976 - implemented the one dimensional composite probabilities
2977 (MHCompProb, MCompProbCalc, comprob.C)
2978
2979 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2980 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2981
2982 - Added a camera display displaying the pixel numbers to the
2983 event display gui.
2984
2985 - Added Monte Carlo Informations to event display gui
2986
2987 - Changed the camera display to display the pixel numbering
2988
2989 - Added three buttons to the camera display to change the palette
2990
2991 - Added the number of used and core pixels after image cleaning
2992 to MHillas
2993
2994 - Changed the algorithm used in MHillas according to TDAS 02-03
2995
2996 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2997
2998 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2999
3000 - Added fCosDeltaAlpha to MHillasSrc
3001
3002 - The numbers of photons used to calculate fConc and fConc1 in
3003 MHillasExt are now scaled with the pixel size, so that one get
3004 a four times smaller value for the bigger pixels in the outer ring.
3005
3006 - added new task to smooth the camera contents (MCameraSmooth)
3007
3008 - added possibility to use interpolated pixel values for blind pixels
3009 instead of removing it completely from the analysis
3010
3011 - Implemented the possibility to save the whole eventloop with
3012 its setup to a file. This information can be read and from
3013 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3014 and MEvtLoop::MakeMacro. If you find something not working, please
3015 report - this stuff is still in a beta phase.
3016
3017 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3018 file having crab starfield, but also for all following files - fixed
3019
3020 - MTaskList::PrintStatistics can now be instructud to print also the
3021 title, too: use PrintStatistics(0, kTRUE)
3022
3023 - Changed the image cleaning so that pixels with to many 'used'
3024 neighbors are left used (to get rid of 'holes' in events)
3025
3026 - Introduced more output to the camera displays
3027
3028 - Added an array of histograms (eg one hist per run), MHArray
3029
3030 - Added a _preliminary_ version of the reader for CT1 PreProc files
3031 (MCT1ReadPreProc)
3032
3033 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3034 (thanks to Raquel)
3035
3036 - added the first energy estimator (MEnergyEstParam, estimate.C,
3037 estfit.C) using a parametrization
3038
3039 - Added some new Monte Carlo paremeter containers used to store
3040 setup information from the MC chain (MMcConfigRunHeader,
3041 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3042
3043
3044
3045 *** Version 0.7 (2002/04/30)
3046
3047 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3048 the pedestal mean value was saved incorrectly. For files from
3049 this versions we substract 0.5 from the pedestal mean.
3050 WARNING: This may effect your results, so don't wonder...
3051
3052 - First implementation of an algorithm using only triggered events
3053 for the collection area calculation
3054
3055 - Ascii Output can now also be used for parameter containers which
3056 doesn't overload MParCointainer::AsciiWrite
3057
3058 - The Ascii Output is now also capable of writing single data members
3059 of one container
3060
3061 - You are now able to change the order of the values written to the
3062 ascii file
3063
3064 - You can now specify a conversion factor for each data member written
3065 to an ascii file. This may be usefull to change the units of the
3066 data member (eg. degrees instead of millimeters in case of the
3067 hillas parameters)
3068
3069 - Replaced old MHillas by a new structure which allows you to extend
3070 the parameters stored in MHillas very easily:
3071 see MHillas and MHillasExt
3072
3073 - Added classes to handle source dependancy of image parameters:
3074 see MHillasSrc
3075
3076 - Added container (MBinning) to have a standard input for the binning
3077 in different histograms (eg. the Energy bins should be the same in
3078 all histograms)
3079
3080 - Changed Hillas histograms from mm to deg
3081
3082 - Added the flexible binning to the hillas histograms
3083
3084 - Added a filter for the alpha parameter (MFAlpha)
3085
3086 - It is now possible to write single data members of a class object to
3087 an output stream instead of the whole container only
3088
3089 - Added a generalized filter for a data member:
3090 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3091
3092 - Added a generalized Filter parser for more difficult filter rules
3093 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3094
3095 - Added new Monte Carlo histograms:
3096 MHMcEnergyImpact and MHMcEfficiency
3097
3098 - Added many new histograms needed for the flux calculation.
3099
3100 - Added a generalized histograms which can fill and show up to three
3101 data members in either a one-, two- or three-dimensional histogram, eg:
3102 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3103
3104 - Added:
3105 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3106 * calculation of <Theta> as a function of time (MHThetabarTime)
3107 they are needed in the flux calculation in
3108 order to select for a given bin in Theta (or time) the appropriate
3109 effective collection area, which is assumed to be given as a function
3110 of Theta and the true energy
3111
3112 - Added calculation of the migration matrix in the energy
3113 (MHMcEnergyMigration):
3114 the migration matrix describes the migration from the true (E_true)
3115 to the estimated energy (E_est); it is needed to determine the
3116 distribution of E_true from the measured distribution of E_est
3117 by unfolding
3118
3119 - changed the color palette in the camera display to DeapSea.
3120
3121
3122
3123 *** Version 0.6 (2002/01/15)
3124
3125 - Introduce the option of disable pixels (MBlindPixels and
3126 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3127 able to deal with Star Field NSB.
3128
3129 - Fixed a bug in the pedestals substraction
3130
3131 - Introduced verbosity levels
3132
3133 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3134
3135 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3136 work correctly (thanks to Abelardo)
3137
3138 - Introduced correct treatment of the diffuse Night Sky Background
3139 and NSB (MMcPedestalNSB)
3140
3141 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3142
3143 - Introduced MMcRunHeaders which contains monte carlo run informations
3144
3145 - Added a 'Print'-Task (MPrint) which calls the Print function
3146 of a parameter container for each event
3147
3148 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3149
3150 - changes to be more efficient with root 3.02/06
3151
3152 - root 3.02/06 fixes:
3153 + the memory leak when reading MRawEvtData
3154 + loosing more time than necessary to update the progress bar
3155
3156 - MWriteAsciiFile is now capable of writing more than one container
3157 in a line. For example: To be able to write Monte Carlo and
3158 Hillas values (energy and alpha) in one line.
3159
3160
3161
3162 *** Version 0.5 (2001/11/06)
3163
3164 - Added new GUI functionality (Analysis)
3165
3166 - Added a camera display to be able to display events in the camera
3167 together with the calculated hillas ellipse
3168
3169 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3170 object at any state of the analysis, so that the output are several
3171 states
3172
3173 - Fixed a bug in the collection area error calculation
3174 (Thanks to Ciro and Abelardo)
3175
3176 - Fixed a bug which causes merpp to crash in some environments
3177
3178 - Implemented auto enabling scheme for Branches to speed up reading
3179 a lot (see MReadTree and MTask)
3180
3181 - Fixed a bug in the Histogram classes which caused histograms to
3182 be written to a file by MWriteRootFile without request
3183
3184 - changed the object I/O from the old stylish root I/O to the new
3185 'auto evolution scheme' This was done only for classes which are not
3186 yet used in Monte Carlo files, so that these files are still readable.
3187
3188 - Added support for a progress bar in MEvtLoop and MReadTree
3189 (see the Analysis Window in Mars for an example)
3190
3191 - Fixed a bug in the package creation which disturbed the conversion
3192 between a mars version unpacked from a tar file and the repository.
3193
3194 - Changed the code to writer merpped (converted into root format)
3195 raw files, to get faster (around 10%)
3196
3197
3198
3199 *** Version 0.4 (2001/09/20)
3200
3201 - This release is made to compile on a root version >= 3.00
3202
3203 - Fixed a bug which causes MReadTree to read the first file only
3204
3205 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3206
3207 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3208
3209 - Added a task to write several container to a root file (MWriteRootFile)
3210
3211 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3212
3213 - Added calculation of the collection area (MMcCollectionAreaCalc)
3214
3215 - fixed some bugs in the Hillas calculation
3216
3217 - added filters to be able to control the task execution dependent on
3218 a parameter (for example: the number of level 1 triggers in a MC-file)
3219
3220
3221
3222 *** Version 0.3 (2001/04/23)
3223
3224 - Many demo macros added
3225
3226 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3227
3228 - Hillas Calculation added
3229
3230 - Standard image cleaning available
3231
3232 - MReadTree is now able to handle more than one file
3233 (Remark: of the same structure)
3234
3235 - Now we are able to display events in a first version of the
3236 Camera event display. To do this we must run the macro
3237 "macros/readCT1.C" to read data from CT1.
3238
3239
3240
3241 *** Version 0.2 (2001/01/24)
3242
3243 - First Implementation of a Gui to read the raw data. Start the
3244 gui with the command mars.
3245
3246
3247
3248 *** Version 0.1 (2000/12/20)
3249
3250 - First official release 0.1
3251
3252 - Changes:
3253
3254 + changed calling style of MRawPixelIterator from do...while to
3255 while-loop
Note: See TracBrowser for help on using the repository browser.