source: trunk/MagicSoft/Mars/NEWS@ 9520

Last change on this file since 9520 was 9520, checked in by tbretz, 15 years ago
*** empty log message ***
File size: 136.4 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 * Added consistency check for two consecutive runs
11
12 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
13 has been disconnected and the L1 (L1TPU) has directly been connected
14 to another bit in the trigger pattern. This has been fixed by an
15 update of the decoding. Both bits are now or'ed together.
16
17 * Added a new camera layout MGeomCamFact which is the "four rectangular
18 pixels ordered in a hexagonal geometry" layout
19
20 * All programs now store the command line as TNamed "CommandLine"
21
22 * the environment variable OSTYPE should now be obsolete. Instead
23 the output of "uname -s" converted to lower cases is used
24
25 * The Makefiles should now detect the OSTYPE automatically using
26 uname. This should make the setting of OSTYPE obsolete
27
28 ;showplot:
29
30 * If a file without a MStatusArray is opened all object (not just
31 canvases) found in the file are drawn. Note that this may result
32 in empty tabs.
33
34 ;ceres:
35
36 * The night sky noise is now scaled with the sensitive area and
37 is given in units per square centimeter
38
39 * Added the possibility to add a cut after the image parameter
40 calculation (''Cut'')
41
42 * updated the PDE of the GAPDs with a more reliable curve from
43 the meeting page (linear extrapolate below 350nm)
44
45 * The impact distribution in the event distrbutions is now
46 perpendicular to Alt/Az and the histogram is displayed in 1D
47
48 * The GAPD PDE has been updated
49
50 * PDEs and mirror reflectivities have been linearily extrapolated
51 to match the wavelegth range between 290nm and 900nm
52
53 * There is no default pulse shape anymoe it must be given in
54 the resource file
55
56 * Fixed a bug which caused the aerosol coefficient to be incorrectly
57 initialized. The effect might be random but seems to be small.
58
59 * Now accepts sequence files as input
60
61 * creation of pedestal and calibration files is now steered by
62 --mode (see ceres help)
63
64 * Instead of initializing the whole G-APD chip (all cells) before
65 each event (which is rather time consuming) a time evolution before
66 each event is now simulated which is enough to recovere every cell
67 to 99.999% of its response taking the background rate into account.
68 This is in total about a factor of ten faster and should not be
69 less accurate because under normal conditions the recovering cells
70 and the newly hitten cells will hardly be identical (due to
71 statistical reasons)
72
73 * improved the trigger algorithm which is now faster and allows easily
74 for multiplicity triggers
75
76 * The PDC flag in the file name is now correctly written
77
78 * A "PreCut" has been added which can be used after reading the events
79 to select them even before any calculation is done.
80
81 ;merpp:
82
83 * The new drive reports which contain also the status of the starguider
84 are now implemented, but the starting date (17/05/09) is preliminary.
85
86 ;callisto:
87
88 * Fixed a bug which prevented MAGIC Monte Carlo file from being
89 calibrated (ceres files worked)
90
91 ;star:
92
93 * allow to run thru even if discriminator threshold are missing
94 (they are not used for analysis so far anyway)
95
96 ;ganymed:
97
98 * added new starguider calibration for sequences since 1000534
99
100 ;database:
101
102 * added possiblity to query/plot data from certain source (with
103 regular expressions) in plotdb.php
104
105 * new feature in showplots*.php: on mouse-over additional information
106 on the sequence is displayed
107
108 * tables on database website have also 'Last' link now
109
110 * new version of builddatasets.php with more comfortable sequence
111 selection
112
113 * new features in builddatasets.php:
114 - user management
115 - 'Get Data Set File' button
116 - 'Display Selected Sequences' button
117 - 'Display Not Selected Sequences' button
118 - 'Select all' buttons
119
120 * builddatasets.php: added possibility to update data sets in the
121 database
122
123 * added limit for cloudiness for sequences in the tab 'Limits'
124
125 ;automation:
126
127 * jobmanager can be used more flexible now: via environnent variable
128 $AUTOMATIONSETUP more than one jobmanager per user can be started
129 using the same MARS version
130 Usage: export AUTOMATIONSETUP=mysetup ; /fullpath/jobmanager
131 and provide a file Mars/datacenter/scripts/setup.mysetup
132
133
134
135== Version 2.3 (2009/03/07) ==
136
137 ;SUGGESTION
138
139 * There is no need to re-run any data because no change took place which
140 could have an effect on the output. However, if you want a
141 meaningful SrcPos plot for your MCs in sponde you must re-process
142 star for your MCs first.
143
144 ;REMARK
145
146 * File produced with this release containing a camera geometry (which
147 are basically all files were produced as default) will not be readable
148 by older releases.
149
150 ;general
151
152 * fixed a few small bugs which could cause the display to crash in ganymed
153 and sponde
154
155 * in sequence file the date can now be omittet. In this case the
156 leading date with the underscore is missing in the expected filename
157
158 * the geometry class now also supports other geometries than just hexagons
159
160 ;automation
161
162 * added magnetic field Azimuth direction (ARRANG), currently
163 at ~ -7deg at La Palma
164
165 ;database
166
167 * plotdb.php: added default (sequences) for startup, added possibility
168 to set size of plot
169
170 * added a new table ''RunDataCheck'' which containes the rates after
171 image cleaning for every run which succeeded star. It can be
172 plotted using ''plotrundb.C''
173
174 ;merpp
175
176 * added support for Arehucas Version >= 200812140
177
178 * added support for Arehucas Version >= 200809030
179
180 ;mars
181
182 * The display now also displays the trigger pattern
183
184 * The display can now display ceres reflector (_R_) files
185
186 ;ceres
187
188 * added a uniformly distributed one-bin time jitter for the start of the
189 digitization. Otherwise the first photon would be digitized always with
190 the same alignment to the bins
191
192 * Added a plot showing the production height of the photons
193
194 * Moved the particle id from the event header to the run header
195
196 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
197
198 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
199
200 * Added many new options to control the tasks. For deatils see ''ceres.rc''
201
202 * Removed obsolete plots in pedestal and calibration mode
203
204 * Removed the non-NightSky photons from the plots where they are just
205 disturbing
206
207 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
208
209 * The daq event number now represents the readout number
210
211 * The camera ''electronics'' can now be ''switched off''
212
213 * A new tab ''Info'' now display basic things like the reflector
214 layout
215
216 * Improved reading speed for corsika files
217
218 * Improved memory handling (if a large ampount of memory was needed
219 for a single event all further events were stored in the same
220 memory and it was never freed, so the program took this memory
221 until the end)
222
223 * Converted the code from MMCS' reflector program to MSimAtmosphere
224 (instead of the tables build in for MAGIC Winter and Summer
225 atmosphere we use the values written by Corsika fitted to the
226 tabulated atmosphere given as input)
227
228 * For caluclating the displayed image parameters in ceres a basic
229 image cleaning removing isolated pixels is now done.
230
231 * The magnetic field direction (ARRANG) is now taken into account
232
233 * Added plot for the energy threshold after trigger ''Threshold''
234
235 * Added plot for the effective collection area after trigger ''TrigArea''
236
237 ;star
238
239 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
240
241 * The definition of fConcCore has slightly changed. The numbers
242 might decrease a little bit (the effect should be rather small)
243
244 ;ganymed
245
246 * added pointing model 328198
247
248 ;sponde
249
250 * The SrcPos plot for your MCs was so far meaningless because it just
251 displayes the MSrcPosCam data from the input star-files. Unfortunately,
252 this containes was never written to the star-files yet.
253
254 * A new Tab 'OnTime' is available which is an effective on-time
255 fit as in star but for all data. This is mainly for manual cross-check
256 of the effective on-time
257
258 * In some circumstances it might be necessary to re-calculate the
259 eff. on-time from the fit in the new tab, e.g. when a zenith distance
260 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
261
262 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
263 it to its own output file (for convinience)
264
265
266
267== Version 2.2 (2009/01/30) ==
268
269 ;SUGGESTION
270
271 * This release doesn't contain a major change which is expected to
272 change your results. Nevertheless there are small changes to
273 the calibration which can effect at least the first few hundred
274 events in any (mainly MUX and even more SUM) sequence a little bit.
275 So it is recommended although not necessary to reset your sequences
276 in the database before further processing.
277
278 ;NEW
279
280 * A first implementation of a Monte Carlo simulation program
281 (ceres - Camera Electronics and REflector Simulation) has been
282 implemented. It can simulate a full telescope already including
283 a complete reflector simulation and a flexible trigger and readout
284 simulation. Currently, no perfect setup is implemented and
285 especially the output of the program (data structure) should
286 be considered alpha state. Also the user interface is not yet
287 ready.
288
289 ;general
290
291 * All command line options after -- are now interpreted as
292 arguments (usually everything which doesn't start with a minus)
293 rather than options (usually everything which starts with a
294 minus). This allows to use file names starting with a -
295
296 * In all resource files you can now initialize the random number
297 generator. For details see: MJob::InitRandomNumberGenerator
298
299 * added a new program called ''readcorsika''. It's purpose is (in analogy
300 to readraw and readdaq) to read a Corsika output file (for now
301 only cherenkov output is supported) and print its contents in a
302 human readable form. It can also write the contents of this file
303 into a root-file.
304
305 * The calculation of the maximum distance to the origin in a MGeomCam
306 has been improved (edges might be further away than the sides).
307 This is just a tiny change but it might change the appearance of
308 the radial profiles a little bit.
309
310 * The default binning of the center-of-gravity plot has slightly been
311 increased
312
313 ;Database
314
315 * Added informations about the DC currents (fMinCurrents, fMedCurrents
316 and fMaxCurrents). The values are retrieved from the plots showing
317 the average DC currents of all pixels versus time.
318
319 * Websites with tables have now the opportunity to remove lines
320 ('-' button at beginning of each line) and get all lines back
321 ('+' at top of the column)
322
323 * Websites: added option to query only sequences containing sumtrigger
324 events
325
326 * Websites: added option to group by date (year, month, night) for runs
327 and sequences and enabled that combining of different group-bys,
328 e.g. status, date and source is possible
329
330 ;automatic analyis
331
332 * Rewritten producing plots in the web.
333 New plots, namely the output of plotoptical.C (extinction curve from
334 KVA), plotstat.C (status of the automatic analysis (percentage of
335 processed, analysed data etc.)) and plotusage.C (statistics of the
336 condor usage in the data center) has been are available now next to the
337 plots of plotdb.C
338 Mean values from the plots (output of the macro) are provided in a
339 txt file now.
340 The creation of the plots for callisto, star and ganymed in the web is
341 now steered via database. Consequently the plots are faster and
342 reliable up-to-date.
343 For all plots, a new layout is available facilitating the browsing
344 through the plots and providing additional information on the
345 displayed values. (tabs.php) These plots are linked from the DB
346 websites and the wiki.
347
348 ;statusdisplay
349
350 * The ''Loop'' entry in the menu bar now contains an option to pause
351 the loop and to process single events.
352
353 ;merpp
354
355 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
356 instead of RunHeaders)
357
358 * Now allows to merpp files newer than 2008/09/03.
359
360 * Added fixes for wrong (wrong or double) run- and file-numbers
361 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
362
363 ;callisto
364
365 * Extracting the pulse position for the pulse position check events
366 with sum trigger were denied. This decreased the statistics
367 extremely and therefor the resulting puse position was calculated
368 quite weak. Now sum events pass the calculation if and only if they
369 have also a level 1 trigger.
370
371 * the extraction of pedestal events and pulse position from the
372 first data events is now more automatic and makes sure that
373 a more precise number of events is extracted independent of
374 the ratio with which pedestal events or events with signals
375 are contained in the data.
376
377 * Updated Muon calibration constants for all MUX data (teh changes were
378 all smaller than 5%)
379
380 ;star
381
382 * For the calculation of the effective on time all sum-triggered events
383 were skipped. Now all Level1-triggeres events will pass. This might
384 result in a slight inaccuracy of the effective on time.
385
386 ;ganymed
387
388 * If the source position is more than 1deg away from the camera
389 center an error is raised now.
390
391 * Hopefully fixed the bug ''ganymed crashes when resized''
392
393 ;sponde
394
395 * Fixed a problem which causes the fitted spectral slope to be displayed
396 incorrectly. If you use MJSpectrum::FormFlux in your macros make
397 sure that the parameter 0 of your fit is negative.
398
399 * Added a histogram showing the read source position of your MCs
400
401
402
403== Version 2.1.1 (2008/08/04) ==
404
405 ;Database
406
407 * Added the median number of photo electrons from the calibration
408 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
409 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
410
411 * Added fTotOnTime, which is the on-time as given by the run-headers
412 (in contradiction to fAbsOnTime which comes from CC)
413
414 * Added new primaries for the new data structure (Magic II): for the
415 tables dealing with sequences (SequenceBuild Status, Sequences,
416 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
417 this is the telescope number (fTelescopeNumber) for the tables dealing
418 with runs (RunData and RunProcessStatus) this is in addition the file
419 number (fFileNumber)
420
421 * Added column fPriority to the status tables to be able to steer the order
422 in which the data is processed. As default the run, sequence and dataset
423 number are used.
424
425 ;automatic analyis
426
427 * Adapted scripts to the new data structure: They can handle now different
428 telescopes (getting the information as usual from the database).
429 The paths for Magic 2 are not yet implemented.
430
431 ;general
432
433 * should work now with root 5.20/00 (please note that root 5.20/00
434 we encounter crahses in the status display which are ot yet
435 understood)
436
437 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
438 instead of the base name of the file. This makes them easier to
439 access from the code
440
441 * Default Monte Carlo names in MSequence do not require the _E at
442 the end anymore
443
444 * where abrrevating a sequence file with a sequence number is possible
445 also "telescope:sequence" is now accepted, e.g.:
446 star 2:2000123 --out=output
447 see the programs' help for more details.
448
449 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
450 from the database. See the constructors for more details.
451
452 * MReadTree now supports friends
453
454 * MReadTree can now read also files not written by MARS and store
455 the data encapsulated in emulated MParContainers
456
457 * added a new starguider calibration valid since 15.1.08
458
459 ;showplot
460
461 * showplot can now read more than one file at once. This is especially
462 inetersting if reading files containing pure canvases
463
464 ;merpp
465
466 * we merpp the dc currents now also from the camera reports (they have
467 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
468
469 * In the automatic analysis we omit merpping of the currents from the
470 caco files and use the lower rate camera reports from the cc files
471 instead
472
473 * merpp has been redisigned to allow merpping of the cc-reports
474 of a whole sequence. This allows to design a very simple analysis:
475 mkdir output
476 ./callisto 100776 --out=output
477 ./merpp 100776 output
478 ./star 100776 --ind=output --out=output
479 Instead of the sequence number also sequence files are accepted.
480
481 * Implemented a fix for run-numbers between 1001348 and 1001396
482 which were incorrectly assigned by the cc.
483
484
485 ;callisto
486
487 * added a filter again which was was removed in the last release.
488 it removed the most brightest events. This should not change
489 any analysis result because these events are so bright that
490 they cannot be analysed anyway, but the bad-pixel plots doesn't
491 show outliers.
492
493 * updated muon calibration constants for the periods 51-57,
494 58-63 and 67-
495
496 ;star
497
498 * The camera currents are now displayed with the rate of the camera
499 reports instead of the caco reports
500
501 ;ganymed
502
503 * if mc camera files are new enough (>=8) the source position in the
504 camera is now calculated from the stored telscope and shower
505 orientation (Note, that this might not be suitable in all cases
506 depending on the aim of the study. These case still needs
507 implementation)
508
509
510
511== Version 2.1 (2008/06/18) ==
512
513 ;Database
514
515 * introduced average temperature and wind speed from star-files
516
517 * introduced average values from Pyrometer (mainly Cloudiness)
518
519 * introduced the ratio of accepted calibration events in the
520 calibration run
521
522 * introduced the average rates of the different trigger pattern,
523 e.g. the rate of pedestal and calibration events, from the signal-file
524
525 ;general
526
527 * fixed GroupBy options in plot*.C macros
528
529 * only display KVA points (not the Tuorla points) in plotoptical.C
530
531 * all programs now allow to add resources to the ones from the resource
532 file or overwrite them from the command line. This can be done like this
533 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
534 if something seems to be wrong you can debug what the program is doing
535 using the option --debug-env=3
536
537 * increased the diversity of debug levels. That also means that with -v3
538 you get now less output, i.e. only the output which is important for
539 an analysis. To get more output which helps for debugging try 4, 5 and 6.
540
541 * fixed a problem in the task synchronizing the reading of the reports
542 and the data stream. The effect was that in some circumstances the last
543 events of some trees could have been skipped. Since this is only a
544 very tiny part of the data no severe effect to your analysis results
545 is expected (an exception might be very short, i.e. singel runs,
546 datasets).
547
548 * Dataset file now allow to include the sequence file directly within
549 the dataset file and also allow to exclude single runs from the dataset.
550 (for more details see Class reference of MDataSet)
551
552 * Sequence files now allow for excluding runs from the analysis
553 (for more details see Class reference of MSequence)
554
555 * added code to process the sum-trigger flag
556
557 * the histogram classes MH3 and MHn now support profile histograms
558
559 * the histogram classes MH3 and MHn now support labels at the axis
560
561 * the Random Forest Train-classes (MJTRain*) now store the used datasets
562 in the output file
563
564 * the MFMagicCuts have a new option to allow a linear area cut (for
565 special studies)
566
567 * The liniking of the shared object is now done into a file defined
568 by 'mktemp'. This should be a local file system which accelerates
569 liniking a lot.
570
571 * The code has been prepared for compilation with root 5.18/00d
572
573 * The MHEnergyEst histogram now shows the distribution of
574 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
575 and (Eest-Emc)/Emc vs Emc.
576
577 * fixed mars (event display) for merpped raw-data and MC data
578
579 * adapted the synatx of sequence files to allow for the new run/file
580 scheme. For more details see class description of MSequence
581
582 ;showplot
583
584 * Added support for tiff files
585
586 * Added support for csv files (tables containing tab number,
587 name and title)
588
589 * Tabs now can have a title which is displayed in the postscript file
590
591 * When multiple file are written at once (e.g. pngs from a display)
592 it is now possible to use the tab name and or tab number in the
593 file name. For details see showplos's help.
594
595 ;merpp
596
597 * Implemented cc file version 2008-02-20/0
598
599 * Implemented cc file version 2008-05-19/0
600
601 * With new options merpping can be restricted (in addition to the
602 run-number) also by telescope and file number.
603 For details see "merpp --help"
604
605 * Implemented raw data format 11 (the most important change, except
606 from plenty of changes in the format definition, is the addition
607 of the file-number in the header) If nobody makes a mistake this
608 format should have the advantage that it is by definition forward
609 compatible, so old programs will be able to read newer formats.
610
611 * Added Pyrometer information to default output (stored in a new Tree
612 Pyrometer, needs a complete new merpp, i.e. new calibration)
613
614 * Merpping (also update) can now be restricted to one single report.
615 For example:
616 If you want to update an old file with Pyrometer information call
617 merpp --only=Pyrometer --update
618
619 ;callisto
620
621 * in the pedestal processing now at least 50 processed events are
622 required for succeeding.
623
624 * the signal and calib files now contain also the sequence information
625
626 * the two MPedestalCam in the calib file now have proper names
627 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
628
629 * Both pedestal cams now contain the number of events processed
630
631 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
632 i.e. for the extraction of the calibration pulses basically the average
633 over all events of the first slice instead of all slices was used.
634 Since pedestal and calibration constants are continously recalculated
635 this only effected the very first events of every sequence.
636
637 * For the extraction of the position of the maximum sample now the
638 extraction range is set automatically to the extraction window,
639 before the whole accessible range was used.
640
641 * If the number of samples in the events and the number of samples
642 in the run-header disagrees now an error is raised (this can
643 happen in not well simulated Monte Carlo files)
644
645 * In the case of MUX-data pedestal events with the lvl1 trigger flag
646 could survive into the pedestal calculation -- fixed.
647
648 * Tab "TrigPat" added showing the distribution of the trigger pattern
649 as found in the run-files (normalized with the run length)
650
651 * The selection of events from the trigger pattern has been improved.
652 If the trigger pattern is corrupted events won't pass anymore.
653
654 * Added a new command line option --dev-null to suppress output of
655 Y-files (this is useful for test cases)
656
657 * added a new tab "CalPos" showing the arrival time of extracted
658 interleaved calibration events
659
660 * Using the new --test switch you can now calibrate the calibration
661 file
662
663 ;star
664
665 * the star file now contains also the sequence information
666
667 * Added a new command line option --dev-null to suppress output of
668 I-files (this is useful for test cases)
669
670 * Tab "Rate" added showing the distribution of the trigger pattern
671 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
672 the Y-files (normalized with the run length)
673
674 * The effective on-time calculation doesn't use events with only
675 sum-trigger anymore
676
677 * The data in the MHWeather tab has been reorganized. The never
678 working solar radiation has been removed and the data from
679 the pyrometer (cloudiness, air and sky temperature) is
680 displayed in addition.
681
682 ;ganymed/sponde
683
684 * Now data points are even shown correctly if they have error bars larger
685 than one sigma. Points with null or negative significances are omitted.
686
687 * DrawNicePlot now allows to set a projection range
688
689 * Updates pointing models. One is applied after the implementation
690 of the new LUTS in August, the other one is applied after the
691 next major change of the pointing model in October. Note that
692 these models are preliminary and give wrong results below Zd=65deg
693
694 ;sponde
695
696 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
697
698 * a new option "--force-runtime" is available. In case of very short
699 datasets (for light-curves) which are in the order of a few
700 minutes the calculated effective on-time is not very acurate because
701 it is quantizised in the order of a minute. Therefore you can switch
702 to using the real run-time instead (remakrt: this ignores any
703 dead-time!)
704
705 * a more analytical way is used to "fill" Monte Carlos into regions
706 of impact parameters which have not been simulated because the
707 trigger efficiency is assumed to be 0.
708
709 * estimated sensitivity curves for hi and lo zenith angles are shown
710 scaled to the correct observation time and collection area
711
712 * the Monte Carlo events after cuts are now written to the output file
713 if an output file given
714
715
716
717 *** Version 2.0 (2007/09/03)
718
719 - database: the position used for the pulse pos check was missing
720 in the callisto output and could thus not be filled into the DB.
721 Also the old values seemed not exactly the PulsePos used for
722 teh check.
723
724 - general: Resource file now allow an Include-Resource, i.e. you can
725 read a resource file with default settings, include it in your
726 resource file and overwrite the settings in your file. More than
727 one include file is allowed. Inclusions can be iterative.
728 Include: mydefaults.rc yourdefaults.rc
729 The resources in the first file have higher priority than the
730 second file.
731
732 - general: Now the output files (calib*.root, etc) also contain the
733 resource file (to check it open it in the TBrowser and choose Print()
734 from the context menu)
735
736 - general: Dataset files now allow to overwrite the default path
737 to search for sequence and data files. Note, that the program
738 option and individual resources will overwrite it. For example:
739 SequencePath: /magic/montecarlo/sequences
740 DataPath: /magic/montecarlo/star
741
742 - general: Fixed a problem with variables in MDataPhrase. It seems
743 that only optimdisp (didn't work) was effected.
744
745 - general: Some improvements to the optim and train processing. For
746 example the ststud window now got a proper title.
747
748 - general: The "Status Display: " was removed from the window title
749 within an Eventloop.
750
751 - general: added a new flexible histogram-class (MHn) which can be used
752 for example in testing after optimizations or training to produce
753 user defined histograms.
754
755 - general: The Random Forest now allows attaching an evaluation
756 function which is applied to its output. This allows to train
757 on whatever you like (eg. train on log10(energy), but return
758 energy)
759
760 - general: The Random Forest training of energy (trainenergy.c) and
761 disp (traindisp.C) has been improved by more graphical output to
762 judge the result.
763
764 - general: The training of energy (trainenergy.C) has been improved
765 a lot by training on a different quantity than energy. It gives
766 a result which is highly independant of the source spectrum
767 and shows lower bias than all other options.
768
769 - general: Dataset files are allowed to contain collections of
770 datasets. For more details see the class reference of MDataSet.
771
772 - general: The default WobbleMode in a datset file now (if not
773 overwritten) is "auto", i.e. wobble mode is set if the dataset
774 doesn't contain off-sequences.
775
776 - merpp: Merpp can read file format version 9 now. Please realize
777 that for file format version 9 the extraction range is different
778 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
779 the first and last 15 slices have been removed from all MUX data.
780
781 - mars: Similar to writing movies you can now select events which
782 should be displayed in your display. Therefore add the following
783 lines to your mars.rc:
784 MFEvtNumber.FileName: ganymed00223552.root
785 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
786 The input file can be a ganymed-file after (ganymed*.root) or
787 before (ganymed*-summary.root) file. For example to select all events
788 from your on sample after cuts (excluding the ThetaSq cut) use
789 MFEvtNumber.Selector: DataType.fVal>0.5
790 To show all events from your on-sample after quality cuts
791 use the summary file instead.
792
793 - mars: new ways to call mars are implemented. Instead
794 of calling
795 mars filename.root
796 you can now also use
797 mars sequence.txt
798 or
799 mars sequence.txt inputpath
800 or replace sequence.txt by the sequence number if the default
801 sequence file should be used.
802
803 - mars: The default size has been increased
804
805 - mars: There are two new heckboxes which allow to switch off
806 the calculated image parameters
807
808 - callisto: was broken for MCs... fixed.
809
810 - callisto: improved calculation of spline coefficients a lot. This
811 leads to a further improvement of the event rate calibrating MUX
812 data of about 15% (175evt/s instead of 150evt/s)
813
814 - callisto: finally the raw data we read is now real 16bit (with
815 10bit precision) for MUX data and not a stripped 8bit number
816 anymore. Due to scaling of the numbers (without precision loss
817 into an [0-256[ range, the final numbers for pedestal, pedestalrms
818 and extacted signal don't change. However, at all places where
819 raw data is directly accessed (eg. saturation and variation
820 limits in the signal- and pedestal-extraction) the numbers
821 refer still to the data's 16bit range.
822
823 - callisto: The maximum arrival time difference used in the bad
824 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
825 for both, old FADC and MUX-FADC, data.
826
827 - callisto: Be aware that callisto is now calibrating the arrival time
828 in nanoseconds rather than time slices. Also all following tasks
829 have been changed to assume ns units now. If you star data
830 calibrated with an older version it might be necessary to adapt
831 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
832 to obtain optimal results. The plot in the PulsePos tab
833 will now be in ns, too. This might also mean that the Muon
834 analysis in star might not work as perfect as expected as long
835 as old files read in.
836
837 - callisto: The calibration constants of earlier updates got lost
838 somehow. All constants have been updated.
839
840 - star: The PSF is now determined from the profile of the ArcWidth
841 instead of arcwidth/radius. The old way gave to much weight
842 to the bins with low statistics. The reference lines have been
843 updated.
844
845 - star: For speed reasons events suitable for the muon analysis
846 are now also preselected by fConcCOG<0.1 which seems to be a very
847 good preselector for muons.
848
849 - star: is now calculating a new timing parameter the Slope along
850 the major and minor axis of the shower. Therefore a numerical
851 solution of a line-fit is used. To use MHillasExt.fSlopeLong
852 and MHillasExt.fSlopeTrans don't forget to multiply it with
853 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
854
855 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
856 have been removed from MNewImagePar. They have never been good for
857 anything.
858
859 - star: Implemented a new recursive algorithm which is supposed to be
860 faster. Also implemented new cleaning oiptions, which are:
861 + CleanLevel0:
862 The cleaning level above single core pixels can be kept
863 + KeepIsolatedPixels:
864 Define whether single core pixels should be kept
865 + TimeLevel1:
866 The coincidence window in nanoseconds to single used neighbors
867 + TimeLevel2:
868 The coincidence window in nanoseconds to two used neighbors
869 + PostCleanType:
870 MOde in which a time dependent post cleaning should be applied
871 0: No post cleaning
872 1: Require for each used pixels at least one used neighbor
873 within a time-window of CleanLevel1
874 2: Require for each used pixels at least two used neighbor
875 within a time-window of CleanLevel2
876 3: Require first two and second one used neighbor
877 within a time-window of CleanLevel1 and fCleanLevel2
878 respectively
879 + RecoverIsolatedPixels:
880 - recoveres isolated core pixels if they have a used neighbor
881
882 - mars/star: The new default cleaning is:
883 + CleanLevel1: 6.0
884 + CleanLevel2: 3.0
885 + CleanTime1: 1.75
886 + CleanTime2: 1.75
887 + PostCleanType: 3
888
889 - star/ganymed: The old spark-cuts have been replaced by new ones.
890 These new spark cuts have been cross checked with the sequences
891 84720 (before splitter), 101041 (after splitter) and 223539 (new
892 FADCs). In all cases they seperate pretty well, but of course not
893 perfect. Monte Carlos have suggested to tighten the cuts a little
894 bit further at low sizes. This has been done.
895
896 - ganymed: IMPORTANT - The spark cuts have been changed to match
897 all available data more or less well. This might mean that for
898 YOUR data there are still sparks visible.
899 Whenever you do an analysis you have to make sure that NO sparks
900 survive your cuts!
901
902 - ganymed: The old hadronness and size cuts have gotten new indices
903 (10, 11). The old indices 8 and 9 now mean an additional condition
904 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
905 If you want to switch off this cut just move the line far away enough,
906 e.g. by setting c[9] to -500. Please update your ganymed.rc files
907 accordingly!
908 The unit of c[9] is deg. It is the dist at which your cut will
909 cross the slope==0. The unit of the slope is ns/deg. So if
910 you readin files calibrated with an older Mars-version you
911 have to adapt the default value for c[9] to the FADCs:
912 - Multiply by two for the MUX FADCs (run number > 200.000)
913 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
914 - Multiply by 42 for the meaning of life (run number = 200.000)
915
916 - ganymed: The old Cut0 is now called CutQ and is calculated before
917 the source position is caluclated. If you need a quality cut
918 including source dependant data (be very carefull with this!)
919 you have to use Cut0 instead.
920
921 - ganymed: now properly supports three off regions in wobble mode.
922 It will be the default from now on in ganymed_wobble.rc. To change
923 the number of off-regions use
924 NumOffSourcePositions: 1
925 in your ganymed.rc. Also by default no off-theta cut will be done
926 anymore so that you will get a background level higher than the
927 signal level in your ThetaSq plot for ThetaSq>0.2.
928 Due to this be carefull changing the scaling mode away from
929 "None". You will underestimate your signal if your scale interval
930 is not properly set.
931 (Rem: ThetaSqN is no longer needed)
932
933 - ganymed: is now storing the events of all (on- and off-)
934 source positions even in the case of more than one off-source
935 position. This should allow sponde to work properly and the
936 energy estimation is done correctly in all cases (without any
937 "nearest position" trick)
938
939 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
940 with a real pointing model for the starguider is done, calibrated
941 with more than thousand tpoints taken from this date on.
942
943 - ganymed: was broken for Wobble-MCs... fixed.
944
945 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
946 has changed. Note that your old ganymed.rc will be incompatible
947 with the new algorithms! Please check the ganymed.rc files and
948 the class description of MFMagicCuts for more information.
949 It is recommended at the moment to use identical Disp-Parametrizations
950 for on/off- and wobble-mode. If cuts are optimized only
951 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
952 should be optimized. All other values should be kept as they are.
953 If you want to do an anylsis without timing a parameters, you can
954 switch off the timing cuts by seeting parameter 7 to a very small
955 value (eg. -99). To remove the slope parameter from the disp
956 paremtrization set parameter 8 to 0.
957
958 - ganymed: The distribution of observation time versus zenith
959 angle is now shown for off- AND on-data.
960
961 - ganymed: The contents of the source position plot are no longer
962 averaged, thus a lot of (fake) events between the two wobble
963 positions have disappeared.
964
965 - ganymed: There is a new tab "CutT" it contains the VsSize plots
966 with the CutT, whihc is defined in ganymed.rc, applied. It
967 is resonable to use your theta-cut for it, to see if there is
968 something strange (sparks!) in your signal-region.
969
970 - ganymed: To choose a dataset from a collection in a dataset file
971 use the new command line option "--dataset=12345"
972
973 - optim, sponde: should now properly support three off-regions.
974 Just produce your ganymed summary files with three off-regions.
975 optim and sponde will automatically get all off events from
976 all off-regions from this file. Please do not forget to
977 set the scaling in optimwobble.C properly:
978 fit.SetScaleUser(1./3);
979 it is not yet read in automatically (will follow soon).
980 In the case of fixed Scale you can also use
981 cuts.SetThetaCut(MFMagicCuts::kOn);
982 no off-cut needed.
983 Be carefull in case of three off-regions when switching on
984 scale mode. Make sure that the scale interval is set correctly.
985
986 - sponde: sponde.rc and sponde_onoff.rc are now idetical
987
988 - sponde: the resouce files have been rewritten with a lot of
989 comments and a well working parametrization for an energy estimator
990
991 - sponde: In the estimated energy versus monte carlo energy plot the
992 contents where exchanged.... fixed.
993
994 - sponde: the so called "accurate"-mode has been removed. It didn't
995 give any improvement in accuracy, only decreased execution speed.
996
997 - sponde: the so called "simple"-mode has been removed. It didn't
998 give any improvement in simple.
999
1000 - sponde: the so called "refill"-mode has been removed. It was anyhow
1001 not implemented.
1002
1003 - sponde: now checks whether the theta distribution of your on-data
1004 and the theta-distribution of your Monte Carlo sample (after
1005 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
1006 sample is incomplete) execution is stopped. Execution can be forced
1007 using the new option --force-theta. Use this option with care!
1008
1009 - sponde: Proper collection areas can now be constructed also from
1010 Monte Carlo samples generated with different maximum impact
1011 parameters. Note that in previous version you neither got
1012 a warning or failure, nor was there any obvious sign that the
1013 collection area was overestimated due to usage of files with
1014 different maximum impact parameters.
1015
1016 - sponde: If MC files with different lower energy limits are used
1017 the primary MC spectrum is artificially completed down to the
1018 lowest energy used at all. WARNING: that this gives correct
1019 collection areas ONLY if none of the events in this region would
1020 survive your cuts at all.
1021
1022 - sponde: the output file now contains more information about
1023 the spectrum (eg. the full 2D collection area histogram).
1024 Note, that this information can only be written to the file
1025 if it is stored automatically via command line argument.
1026 If you only store the status display from within the display
1027 the information is lost.
1028
1029 - sponde: added a new tab "Disp". It shows the residual of the disp
1030 (Disp-Dist) versus several parameters and it is meant to judge the
1031 quality of the disp estimator. In the ideal case the residual is zero
1032 and doesn't depend on any variable. The tab is displayed after
1033 CutQ and Cut0.
1034
1035 - sponde: added a new tab "Energy". It shows the residual of the
1036 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1037 several parameters and it is meant to judge the quality of the
1038 energy estimator. In the ideal case the residual is zero
1039 and doesn't depend on any variable. In reality even a good estimator
1040 can show residuals versus Monte Carlo energy. The tab is displayed
1041 after all cuts.
1042
1043 - sponde: added a new tab "EventDist" showing the unweighted real
1044 absolute number of events of your sample after cuts. This tells
1045 you how many events with this energy you had in your MC files.
1046 The same information you get from the error bars of the weighted
1047 histograms, but this is less intuitive.
1048
1049 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1050 for comparison. It is not meant to show these curves in
1051 publications, they are only for production.
1052
1053 - sponde: The OriginalMC tree with the events produced by corsika
1054 is now processed only once
1055
1056 - sponde: Finally fixed most annoying bug, which has effected the
1057 last bin of the collection area. It was the problem that binnings
1058 of root histograms are from 1 to n (included) but there was a C-like
1059 loop in sponde from 0 to n (excluded). Now the loop also includes
1060 correctly under- and overflow-bins. The worse thing with this is,
1061 that for the events in the highest bin not only the bin-content
1062 was wrong, but also the weights applied to these events, which could
1063 in pricipal effect also other parts of the distribution (eg. due
1064 to energy estimation). Fortunately it effected only a few events
1065 in most cases.
1066
1067
1068
1069 *** Version 1.2 (2007/05/14)
1070
1071 - database: The database now has two new values Unsuitable50 and
1072 Unsuitable01. They express the number of pixels which are
1073 unsuitable for more than 50%, respectively more than 1%, of
1074 all calibrated event. It is a more accurate number than the
1075 previously used numbers, because they only take the first
1076 calibration (ignoring the interleaved calibrations) into account.
1077
1078 - database: The database now has two other new values UnsuitableMax and
1079 DeadMax. They express the maximum number of pixels which were
1080 unsuitable, respectively dead, during the sequence. Because
1081 of high pedestal rms (cars passing) a few events with very high
1082 numbers of unsuitable pixels can happen. Not to suffer from this
1083 effect we don't take the highest 0.1% of the numbers into account.
1084
1085 - general: fixed a bug which caused callisto and star to stop working
1086 properly because the callisto output was currupted
1087
1088 - general: a script called scripts/makemovie has been added which
1089 simplified the process of producing several movies from a single
1090 sequence with different setup.
1091
1092 - callisto: Some more code cleanup. Started to remove old obsolete
1093 code from cvs.
1094
1095 - callisto: The extraction of the pedestal with the extractor was
1096 not random. It seems that extracting at one position is still biased
1097 (for example in the first or last slices we could still suffer from
1098 switching noise) Now it is completely random.
1099
1100 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1101 pedestal files) individual pixels could be skipped due to high
1102 variations. This was already the case for the pedestal extraction
1103 from the lo-gains since the beginning and properly handled
1104 there, but was introduced in the extraction from the pedestal files
1105 a while ago. To calculate the average value it was still divided
1106 by the number of events procesed not by the number of summands
1107 really summed. This let to a pedestal which was a tiny amount too
1108 small (for a few piels in the order of 0.1%). This led to an slightly
1109 positive offset of the randomly extracted pedestal for a few pixels.
1110 I doubt that this has a big effect on the result, because the effect
1111 on the individual numbers is quite small. Due to this it is suggested
1112 that you rerun your calibration to make sure you are without any
1113 avoidable bias.
1114
1115 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1116 the median rms of the absolute arrival time and expressed in significance
1117 levels. This replaces the old meaning of an abolute upper limit. An
1118 absolute upper limit doesn't make much sense, because in our data
1119 all arrival times are shifted at the same time (in fact it might be
1120 a shift of the artificial trigger w.r.t. to the light flash).
1121
1122 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1123 of the number of unsuitable pixels over the whole sequence. This
1124 is usefull mainly to judge if an intermediate calibration had
1125 problems.
1126
1127 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1128 of the number of dead pixels over the whole sequence. Dead pixels
1129 in this context are unmapped pixels, i.e. pixels which could not
1130 be interpolated, and thus are ignored in the further analysis.
1131
1132 - callisto: It is now possible to use the position of the maximum
1133 of the spline as arrival time instead of the leading edge even
1134 when using the integral for the signal. Therefor set the extraction
1135 type to kIntegralRel ("IntegralRelative") and the relative height
1136 ("HeightTm") to -1:
1137 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1138 MJPedestalC1.ExtractSignal.HeightTm: -1
1139
1140
1141
1142
1143 *** Version 1.1 (2007/04/27)
1144
1145 - general: The new class MGeomCamDwarf contains the camera geometry
1146 for our prefered Dwarf camera and can be used to create general
1147 geometries of roundish or hexagonal cameras.
1148
1149 - mars: The default cleaning is now abolute 8.5/4.0.
1150
1151 - mars: The resource file mars.rc now contains examples for MUX data
1152
1153 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1154 data containing only 10-bit information is still cooked down to
1155 8-bit, by cutting away the lowest 8-bit.
1156
1157 - merpp: When reading raw data the data is now stored in a single
1158 array. The lo-gain array is obsolete. The interface stays the same.
1159
1160 - callisto: To process the new MUX data use the resource file
1161 callisto_mux.rc
1162
1163 - callisto: The -root and -raw options to read merpped raw data have
1164 been removed
1165
1166 - callisto: If the -mc option is given the sequence-name can now be
1167 replaced by the MC sequence number
1168
1169 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1170 -mc option can now be omitted
1171
1172 - callisto: Started further simplification by removing obsolete
1173 dependancies on MCalibIntensity*Cams.
1174
1175 - callisto: removed unsused intensity calibration from MJCalibration
1176 for further simplification
1177
1178 - callisto: for simplification removed references to
1179 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1180 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1181 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1182 (this should at minimum change nothing at all, and at maximum
1183 improve thing if these containers where somewhere not handled
1184 properly)
1185
1186 - callisto: Added the option to write an event movie. Please use
1187 this option with care (huge files) but exessively to understand
1188 our events. For further documentation please refer to the
1189 IACT wiki
1190 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1191
1192 - callisto: Improved binning for the pulse position check histogram
1193
1194 - callisto: The code calculating the pulse position checknow takes
1195 the pedestal into account
1196
1197 - callisto: The arrival time is now stored with full precision this
1198 helps to get rid of artefacts in histograms. For the signal this
1199 is not necessray because it is displayed in log-scale anyhow
1200
1201 - callisto: Fixed a problem with internal exclusions. Pixels which
1202 have once been marked as unsuitable didn't get the necessary
1203 histograms filled anymore to be rechecked with each interleaved
1204 calibration.
1205
1206 - callisto: The relative arrival time resolution (the rms of the
1207 relative arrival time offset) is now checked against its
1208 median and the median deviation, instead of the average
1209 plus an absolute offset.
1210
1211 - callisto: The relative arrival time offset is now calculated
1212 w.r.t. its median not w.r.t. to an artificial reference pixel.
1213
1214 - callisto: The relative time calibration now marks pixels with
1215 outlaying offset as unsuitable
1216
1217 - callisto: The interleaved relative time calibration has been switched
1218 on. The advantage is that pixels which are marked as outliers
1219 now can recover. An improvement over time is not expected, because
1220 the relative time calibration seems stable.
1221
1222 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1223 option can now be omitted.
1224
1225 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1226 or the option "-mc" is specified as default the monte carlo datacenter
1227 paths (/magic/montecarlo/...) are used if not overwritten in the
1228 dataset file.
1229
1230 - ganymed: The output files now contain run- and event-number for all
1231 events, accessible as RunNumber.fVal and EvtNumber.fVal
1232
1233 - ganymed: Added a plot showing the source position in the camera also
1234 for wobble mode
1235
1236 - ganymed: In addition to the existing task which can be setup to
1237 be executed after Cut1 a final task called "EstimateEnergy"
1238 has been added, executed before writing the final output
1239 (ganymed00000000.root). The task setup in all three cases
1240 can be choosen individually. (For all three(!) cases you
1241 can for example choose MRanForestCalc. For examples see all
1242 sponde*.rc and all ganymed*rc)
1243
1244 - ganymed: If a container "MEstimatedEnergy" is found in the
1245 parameter list (eg. because it was setup by MEstimateEnergy)
1246 it will be written to the output file.
1247
1248
1249
1250 *** Version 1.0 (2007/02/16)
1251
1252 - database: Website to plot values from the database has been added.
1253
1254 - database: The rate of spark events as found by star is now kept
1255 and the rate after cleaning is now with spark events subtracted
1256
1257 - general: The changes to the interpretation of phrases lead to
1258 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1259
1260 - general: Added example files how you can create your own calendar
1261 (eg. as christmas present) with Mars. Just run
1262 root macros/tutorials/calendar.C
1263
1264 - general: Added a possibility to display grouped data in the plotdb.C
1265 macro (and similar macros). This allows to plot hourly, nightly,
1266 weekly, monthly and yearly averages.
1267 For more details see the plotall function of the macro
1268
1269 - general: fixed the error display of the camera display. It showed
1270 wrong results.
1271
1272 - general: fixed a memory leak when reading many MStatusDisplays
1273
1274 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1275 between a spherical and a parabolic mirror
1276
1277 - callisto: We have a new pulse position check which takes the properties
1278 of the extractor automatically into account. So no need to set
1279 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1280 left is done. If possible the lo-gain extraction start and hi-gain
1281 extraction end is changed accordingly. If no proper extraction range
1282 can be set (hi-gain too much to the left) an error is raised.
1283
1284 - callisto: New swapped pixels have been found and corrected
1285
1286 - callisto: Redone the signal extraction this includes:
1287 + Unified the algorithms to extract the pedestal for all pedestal
1288 extractions done
1289 + Unification of hi- and lo-gain into one array
1290 + Unification of hi- and lo-gain extraction for Spline and
1291 Digital Filter (means now exactly the same algorithm is used,
1292 not a copy-and-pasted one)
1293 + Store pedestal subtracted data in a common place
1294 + Improved extraction algorithms. If the algorithms search a
1295 maximum but don't find one they don't return the maximum anymore
1296 + Improved the extraction such that a information for signal
1297 and time which is consistent is returned
1298 + replaced the numerical spline with a (not slower) analytical
1299 solution
1300 + Lowered the saturation limit from 250 to 245 to make sure that
1301 we are far away in all pixels from problems with the clock-noise
1302 + The start of the lo-gain extraction is calculated from the hi-gain
1303 arrival time. In case of saturation an estimation is used.
1304 + the hi-gain window was extended to slice 16. This allows extraction
1305 of very late pulses in single pixels or of huge hadron showers.
1306 + Now uses the lo-gain extraction range for pedestal extraction,
1307 not the hi-gain range in the lo-gain
1308
1309 - callisto: New hi-/lo-gain calibration constants have been produced
1310 for all periods from the statistic of the whole period. They are
1311 now used automatically depending on the periods. The old constants
1312 where deviation in avarega about 2%-3%. The constants are very
1313 stable from period to period (<<1%) except for exchanged channels.
1314 In a few cases the constants used so far were off by 1%-2% (maybe
1315 temperature effects?)
1316
1317 - callisto: To gain obsolete space we do not write the
1318 MPedestalFundamental anymore. Also calibration and bad pixel
1319 treatment is not done for it anymore because it has never been used.
1320
1321 - callisto: Fixed a bug in the seuqence handling which caused the
1322 light condition to be ignored
1323
1324 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1325 basically the same as "Cleaned" but the distribution devided into
1326 the events fullfilling a spark cut or being rejected by it.
1327 This cut can be changed from star.rc (see example inside) by
1328 the "SparkCut" directive
1329
1330 - star: Star displays now the average individual pixel-rate (IPR) versus
1331 time and the average discriminator threshold (DT) of all pixels.
1332
1333 - optim: fixed a problem with the optim-macros which was due to a bug
1334 in the new phrase parsing
1335
1336 - ganymed: To get a nice FalseSource plot (instead of the all-information
1337 debug plot displayed as a standard plot) use the context menu
1338 somewhere between the two upper plots, click on "DrawNicePlot"
1339 and enjoy the result. (It is the same context menu which contains
1340 the other options)
1341 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1342
1343 - ganymed/optim/train: The cut program, trainings- and optimization
1344 macros could run with less files found than expected from the
1345 sequence-files. No the execution is stopped in this case.
1346
1347 - ganymed: now stores the dataset in the output file with all information
1348 contained (as sequence number, sequence path, data path) so that the
1349 used dataset file can be recreated complete from the output
1350
1351 - sponde: now also allows the uasge of random forest
1352
1353 - sponde: added a plot showing the cut efficiency
1354
1355 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1356 errors (eg. effecting the collection area) because the errors of the
1357 two histograms were swapped in the calculation, which makes a difference
1358 in the case the histograms contains weighted events. Aditionally the
1359 totalarea was incorrectly taken into account, which results in too small
1360 errors, which makes a difference at low statistics were the errors
1361 or the collection area dominate.
1362
1363
1364
1365 *** Version 0.10.3 (2006/10/23)
1366
1367 - database: Implemented ObservationMode flag in websites.
1368
1369 - database: For sequences there is now also the stoptime available on the
1370 websites.
1371
1372 - database: Removed ManuallyChanged flag from sequence-info websites,
1373 as it is not needed anymore with the new sequence building algorithm.
1374
1375 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1376 Class for calculation of confidence intervals (upper limits).
1377 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1378 Please read the class instruction of TRolke for more information.
1379
1380 - general: The programs now return 0xfe if the requested resource file
1381 doesn't exist.
1382
1383 - general: Errors comming from root itself are now not output to
1384 stderr anymore but to our default (colored) log-stream.
1385
1386 - general: Changed the interface to TFormula such that now everything
1387 is parsed by TFormula, which should allow to use phrases even
1388 without paranthesis correctly parsed.
1389
1390 - callisto: replaced the AdHoc number of effective integration slices
1391 in the digital filter by an average of the correct number, averaged
1392 over all possible set of weights. This also gives correct numbers
1393 for the lo-gains which were totally wrong before.
1394
1395 - callisto: drastically reduced memory consumption by not storing
1396 all intermediate calibration results in memory anymore (we might
1397 write them into a file in the future)
1398
1399 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1400 debug plot displayed as a standard plot) use the context menu
1401 somewhere between the two upper plots, click on "DrawNicePlot"
1402 and enjoy the result. (It is the same context menu which contains
1403 the "DrawAll" option)
1404 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1405
1406
1407
1408 *** Version 0.10.2 (2006/10/15)
1409
1410 - general: changed the building of the sequence files such, that
1411 the source-/project name in case of wobble-sources is not the
1412 source/project of the first data run anymore but the new generalized
1413 wobble source/project
1414
1415 - general: Added some functions to MAstro to calculate sun and
1416 moon properties
1417
1418 - general: Added two new macros (starvisday.C and starvisyear.C)
1419 which allow to plot the visibility of several stars in one day
1420 or of one star along one year
1421
1422
1423
1424 *** Version 0.10.1 (2006/10/11)
1425
1426 - general: HTML logging output was distorted... fixed.
1427
1428 - general: Changed the writing of the sequencefiles such that only
1429 as many pedestal files as giving at least 1000 pedestal events which
1430 are nearby the first calibration run are used as pedestal runs
1431
1432 - sponde: In the calculation of the collection area(s) and the
1433 distribution for MOnte Carlo and estimated energy the error
1434 calculation was wrong because root didn't take the errors
1435 properly into account... fixed.
1436
1437
1438
1439 *** Version 0.10 (2006/10/10)
1440
1441 - general: all executables now check consistency of the root version
1442 installed with the root version used for compilation. The return
1443 code in this case is 255.
1444
1445 - general: The algorithm to build seqeunces has been redesigned
1446 completly. It is now more flexible in terms of a resource file
1447 resources/sequences.rc which can be used to partly overwrite
1448 the default algorithm and defined the important part of the
1449 algorithm. It also takes correctly into account several ways
1450 of taking wobble-data. Currently the new algorithm doesn't take
1451 the number of pedestal events anymore into account (so a sequence
1452 could have much less than 1000 pedestal events and data runs are
1453 no-more used instead)
1454
1455 - general: a lot of small changes to make the code compatible with
1456 root 5.12/00 and gcc 4.1
1457
1458 - general: Fixed some warnings thrown if more warnings are switched
1459 on in the compiler
1460
1461 - general: Added a function to MMath which returns the Median of
1462 the distribution abs(y[i]-median) but at 68:32 division instead
1463 of 50:50, which is somehow the median counterpart of the rms.
1464
1465 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1466 even if they are compressed with gzip (recommended compression
1467 is with "-1")
1468
1469 - showplot:
1470 + batch mode creation of image files now works with root 5.12/00
1471 + added support for writing bmp (though it never produces
1472 bmp which can be read by programs like xv or gimp)
1473 + added support for xml
1474 + added new option to start the display with a different size, by
1475 --display-width=nnn or --display-height=nnn
1476 + added options to define the canvas size when the display is started
1477 --canvas-width=nnn or --canvas-height=nnn
1478 the option can also be used for batch-mode conversion
1479 + added an option which automatically fits the display size to the
1480 desktop-size: --auto-size
1481
1482 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1483
1484 - merpp: allow the reports to have 1000ms due to a bug in the camera
1485 program.
1486
1487 - callisto: New swapped pixels have been found and corrected. For
1488 details see MRawRunHeader::FixAssignment()
1489
1490 - callisto: Callisto now raises an error if one of the input files could
1491 not be opened.
1492
1493 - callisto: In some rare cases it could happen that in the signal
1494 extraction of the digital filter the extractor returned nonsense
1495 results due a wrong initializion of a variable (this happens in
1496 cases in which the extracted signal is exactly zero or the
1497 digital filter couldn't slide because of a too small extraction
1498 window, which could happen in the lo-gain extraction)
1499
1500 - callisto: The lo-gains have been marked as valid in some cases
1501 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1502 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1503 smaller than the number of slices (fLoGainWindowSize) needed
1504 by the lo-gain extractor
1505
1506 - callisto: Updated absolute calibration constants (muon calibration)
1507
1508 - callisto: fixed a bug which caused the hi-gain saturation not
1509 to be handled properly in the spline (the position of the
1510 saturation was calculated incorrectly)
1511
1512 - callisto: fixed a bug which gave weird results if hi- _and_
1513 lo-gain could not be extracted properly. In some cases hi-
1514 and lo-gain have not been extracted at all and the random result
1515 got calibrated. In other cases the hi-gain was saturating and the
1516 lo-gain has not been extracted. For this a completly arbitraty
1517 scale factor was applied to the result from extracting the
1518 charge of the saturating hi-gain.
1519
1520 - callisto: improves handling of extracted signal if lo- and/or
1521 hi-gain could not be extracted properly. If no appropriate
1522 calibration of either the signal or the arrival time is possible
1523 the pixel is now markes as unsuitable instead of estimated.
1524
1525 - callisto: Fixed a problem in the spline extraction which gave
1526 weird results if the signal was extracted from the first (and
1527 highest) slice (as a workaround extraction from the first
1528 slice has been forbidden)
1529
1530 - callisto: Fixed a bug regarding the use of the QE which doesn't
1531 effect the result because the default is used anyhow.
1532 (The bug was there since 14/07/2005)
1533
1534 - callisto: Changed the default for fgLoGainStartShift to -2.4
1535
1536 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1537 factors to be always 10 for all pixels as soon as the first
1538 calibration update has happend.
1539
1540 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1541 was off by more than one slice (which gives wrong values for
1542 pixels which have saturated the hi-gain) This was a problem
1543 mainly for timing studies, not so much for the automatic standard
1544 analysis. Also the values for the Spline have been changed slightly:
1545 + Digital Filter from 1.70 to 0.95
1546 + Spline from 1.39 to 1.30
1547 The numbers were sorted out by an extensive test in the
1548 test-database.
1549
1550 - callisto: Removed the tab showing the average calibrated arrival
1551 time. It never gave useful information.
1552
1553 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1554 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1555 and both were extracted because the hi-gain was above the
1556 LoGainSwitch.
1557
1558 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1559 lo-gain pulse position (after application of LoGainOffset, which
1560 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1561 have saturated and both were extracted because the hi-gain was above
1562 the LoGainSwitch.
1563
1564 - callisto: After extensive tests a new threshold level for determination
1565 of the pulse position has been found at 50phe. This is due to the
1566 fact that for lower pulses the arrival time changes its average
1567 behaviour dramatically. It tends to the average of the extraction
1568 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1569
1570 - callisto: Added two more plots to the calibration part. The average
1571 extracted signal and the average extracted arrival time as
1572 extracted by the signal extractor (This can help debugging problems
1573 because it doesn't involve a fit)
1574
1575 - star: changed the fit for the effective on time such that initial
1576 values are calculated automatically now instead of using build
1577 in values. This makes the fit more indepedant of the underlaying
1578 rates. With a test of ~350 sequences in the test database it could
1579 be shown that the new fit gives the same result +/-1sek.
1580 The highest deviation was +5s the lowest -10s. You can now control
1581 the bahaviour with two resource values:
1582 MHEffectiveOnTime.FistBin: 3
1583 MHEffectiveOnTime.NumEvents: 12000
1584 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1585 from the resulting gamma candidates
1586
1587 - star: The Center histogram in MHHillas is now by default displayed
1588 with the colz draw-option
1589
1590 - ganymed: now produces valid error codes if failed
1591
1592 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1593 with the option "hadronness" instead of "area" or "both" if
1594 you want to use both cuts. The hadronness cut includes a fixed
1595 cut in hadronness (index 8) and a fixed cut in size (index 9).
1596
1597 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1598 the M3Long of the anti source to be not properly evaluated
1599 (actually is was evaluated as a unique random number) in case
1600 of optimization with anti-theta cut switched on. This might have
1601 lead to improper, but not necessarily wrong, optimization results.
1602
1603 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1604 how to use random forest
1605
1606 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1607 ganymed_onoff.rc. Seems to be unintentional that they were different.
1608
1609 - sponde: Since the introduction of the possibility to define a
1610 normalization energy instead of using the integral the default
1611 was not using the integral anymore but a normalization energy of
1612 1GeV. It is now the integral again.
1613
1614 - sponde: Fixed a problem in the weighting which did not allow
1615 a MC slope of -1.
1616
1617
1618
1619 *** Version 0.9.6 (2006/05/24)
1620
1621 - general: changed the binning of the azimuthal profile of the camera
1622 such that it is aligned with the 60deg boundaries.
1623
1624 - merpp: better handling of problems with the TH, TD part of the
1625 CC-REPORT for files older than 200507190 and 200412210
1626 respectively
1627
1628 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1629
1630 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1631
1632 - callisto: if an arrival time is extracted outside the fadc range is
1633 was set to the boundary before. Now a random number is assigned
1634 instead to avoid unfortunate coincidences of arrival times just
1635 by this arbitrary value.
1636
1637 - callisto: added a new option to callisto.rc which allows
1638 to set the maximum arrival time difference allowed for the
1639 badpixel algorithm to determin whether a pixels belongs to a shower:
1640 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1641
1642 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1643 to 0.9 as suggested by Stefan due to a recent study on the fraction
1644 of pixels surviving the image cleaning
1645
1646 - callisto: switched off error in case of "pulse is too much to the left"
1647
1648 - callisto: The extraction window is not adapted anymore. This means that
1649 the pulse is extracted from the full range. The draw-back is that the
1650 background (pedestal) will become slightly higher. Switching on/off
1651 the PulsePosCheck in the callisto.rc only effects filling the
1652 histograms.
1653 WARNING: If the pulse is too much to the left data is calibrated!
1654 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1655 in the database to make sure that your data is valid!
1656
1657 - star: Show also the number of stars correlated correctly by the
1658 starguider
1659
1660 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1661 than one off-source region in wobble-mode. To use it add the following to
1662 your ganymed_wobble.rc:
1663 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1664 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1665 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1666 + Cut1.ThetaCut: None
1667 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1668
1669 - ganymed: in the case the latest report is older than a default (currently
1670 one minute) and the current report will be skip the starguider
1671 correction and calibration will be reset. The maximum age can be
1672 setup from ganymed.rc by (minutes):
1673 MPointingDevCalc.MaxAge: 1.5
1674
1675 - ganymed: A first implementation showing all size-bins for the theta-sq
1676 resp. alpha-plots in a single tab automatically
1677
1678
1679
1680 *** Version 0.9.5.1 (2006/05/05)
1681
1682 - general: Added a new option "zdiff" to the Makefile which runs
1683 "cvs diff" as "make diff" would do, but with compression
1684
1685 - general: accelerated MTFillMatrix (used for eample in all training
1686 and optimization macros) by skipping some obsolete calles in the
1687 eventloop the first and second loop could be accelerated by ~20%
1688
1689 - general: Added a missing feature in the MFilterList class which
1690 prevented MFEnergySlope from working correctly in trainenergy.C
1691
1692 - general: Accelerated the random forest training and usage a bit
1693
1694 - merpp: Adapted to new raw data file format version 6
1695
1696 - merpp: fixed a problem with reading the starguider reports
1697 after 6.3.2006
1698
1699 - callisto: At some times six pixels had to be exchanged manually in the
1700 data. If the pixels to be swaped are both not found, an error was raised
1701 and calibration was stopped. Now it is assumed they are intentially not
1702 mapped and the Error has been changed to a Warning.
1703
1704 - star: Added new image cleaning based on the arrival time of the shower.
1705 The new cleaning can be accessed using the parameter "Time" instead of
1706 the the old one (like "Absolute) in the star.rc-file.
1707 Recommended parameters:
1708 + MImgCleanStd.CleanLevel1: 8.2
1709 + MImgCleanStd.CleanLevel2: 5
1710 + MImgCleanStd.CleanRings: 2
1711 + MImgCleanStd.KeepSinglePixels: No
1712
1713 - star: Simplified the calculation of the effective on time. By letting
1714 the fit start in the third bin the result should become more stable.
1715 The fit quality is now ignored for the theta-plot which is not used
1716 in the analysis later. Still better pre-cut which, for example,
1717 remove events triggered by car-light (rate changing on a short
1718 time-scale) are missing.
1719
1720 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1721 for optimization (kWeakSource) which is suggested by the Berlin
1722 people for weak sources.
1723
1724 - macros: plotdb.C:
1725 + if no dataset and no time-interval is given only sequences with
1726 an effective on-time above five minutes are plotted anymore
1727 + added a new tab "RelTime" displaying the relative on-time
1728 (effective on-time divided by the observation time)
1729
1730 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1731 the optimization became a lot faster
1732
1733 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1734 To display them just delete the pads displayed on top.
1735
1736 - ganymed: fixed a bug which could cause strange behaviour in wobble
1737 mode if no starguider information was available due to an incorrect
1738 initialization of the starguider calibration
1739
1740 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1741 be changed from within the plot. It can also be setup from the
1742 resource file using:
1743 + MHDisp.fScaleMin: 0.325
1744 + MHDisp.fScaleMax: 0.475
1745
1746 - ganymed, showplot: Fixed a problem with the fit to the off-data
1747 (HistOff) which could cause a time lag or an inifinite loop.
1748 The bug did not effect the results at all.
1749
1750 - sponde: Added a new tab showing the effective collection area after
1751 trigger (including the software trigger)
1752
1753 - sponde: MMcSpectrumWeight has a new option which allows to define
1754 the scaling factor not by the integral of the events but at
1755 a defined energy:
1756 e.g. MMcSpectrumWeight.NormEnergy: 200
1757
1758 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1759 eventloops the loop could be accelerated by ~20%
1760
1761
1762
1763 *** Version 0.9.5 (2006/03/13)
1764
1765 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1766 and added the standard Disp-parametrization
1767
1768 - macros: added a new macro datacenter/macros/plotstat.C allowing
1769 to plot statistics about the data processing
1770
1771 - macros: added a new macro to plot the muon correction coefficients
1772 versus period (macros/plot/mucal.C)
1773
1774 - showplot: path inflation for ganymed files was broken
1775
1776 - callisto: Fixed an important bug. When the number of saturating pixels
1777 were calculated the bad pixel information already available from the
1778 calibration was ignored. This yields wrong values in case pixels
1779 are broken and saturate all the time or randomly.
1780
1781 - callisto: Updated Muon calibration constants. Spline data now also uses
1782 different values for different periods
1783
1784 - star: The time-evolution shown in the effective on-time plot now displays
1785 the axis range (if there are no holes it should be similar to the
1786 effective on-time)
1787
1788 - star: Added two new image parameters:
1789 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1790 the three pixels next to the center of gravity and the size
1791 + MNewImagePar.fConcCore: The ratio of the signals of all
1792 pixels inside or touching the ellipse and the size
1793
1794 - ganymed: now stops in requested source isn't found in catalog file
1795
1796 - ganymed: Many improvements to the phi-plot in wobble mode:
1797 + with a template the ideal background is displayed
1798 + a possible camera inhomogeneity is taken into account
1799 + the anti theta cut is better supported
1800 + the phi cut is automatically calculated from the theta cut
1801 See the examples in ganymed_wobble.rc for more details.
1802
1803 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1804 times the bin-width instead of the absolute energy
1805
1806 - ganymed: New cuts for on/off and wobble mode
1807
1808 - ganymed: The smearing of the False Source plot has been increased
1809 to 0.06
1810
1811 - ganymed: The starguider calibration can now be changed from the
1812 resource file.
1813 See the examples in ganymed*.rc for more details.
1814
1815 - ganymed: added a new option for on-/off-observations
1816 MJCut.RandomSourcePosition
1817 If switched on the distribution of observation time of the source
1818 position in the camera is calculated from the on-data and randomly
1819 applied with this distrbution to the off-data.
1820
1821 - ganymed: by skipping some obsolete calles in the eventloop the
1822 first and second loop could be accelerated by ~20%
1823
1824 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1825 position in the off-data randomly according to its distribution in the
1826 on-data.
1827
1828
1829
1830 *** Version 0.9.4.3 (2006/02/13)
1831
1832 - general: Fixed a bug in most of the programs which prevented the
1833 compile date in the startup message to be displayed
1834
1835 - general: Simplified program calls. The following abbreviations
1836 are now possible:
1837 showlog callisto 55599
1838 showplot signal 55599
1839 star 55599
1840 callisto 55999
1841 ganymed 2
1842 In this cases the corrsponding root-, log-, sequence- or dataset-
1843 filename is automatically compiled using the default datacenter
1844 paths ("/magic/*")
1845
1846 - general: Fixed a long outstanding bug which made axis tick marks
1847 disappear if MDataFormula was used (eg. abs(x))
1848
1849 - general: Updated MMath with new functions to calculate the results of
1850 a exponential, logarithmic and powerlaw fits analytically.
1851
1852 - general: Updated some macros with comments:
1853 + macros/optim/optimdisp.C
1854 + macros/optim/optimenergy.C
1855 + macros/optim/optimwobble.C:
1856
1857 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1858 files) now allows adding a pre-cut like in the optimization. E.g. this
1859 is useful to perform g/h-separation cuts before training the random
1860 forest.
1861
1862 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1863 correctly assigned in the raw data assignement table. A fix to correct
1864 the assignment tabel have been implemented.
1865
1866 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1867 by 90, 180 and 270 deg.
1868
1869 - general: the macro plotdb.C now allows to highlight sequences belonging
1870 to a datset. For more details see the descritions in the macro.
1871
1872 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1873 of the display, it gave wrong results espacially for big sizes.
1874 Now the embedded canvas should always have a ratio width/height=3/2.
1875 The "Size" options have been updated with values fitting the 3/2
1876 size ratio.
1877
1878 - RanForest:
1879 + Updated the random forest classes to support also the
1880 regression method implemented by Thomas H.
1881 + added new tutorial macro how to train the random forest
1882 for energy estimation (macros/optim/rfenergyest.C)
1883 + new classes to train the random forest (still in development)
1884 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1885 + new tutorial macros for random forest training in macros/train
1886 trainenergy.C, traindisp.C, trainseparation.C
1887
1888 - mars: now allows to setup a cut in the resource file mars.rc to choose
1889 the events to be displayed, eg:
1890 Cut.Condition: {0} && {1}
1891 Cut.0: MHillas.fSize>100
1892 Cut.1: MHillas.fSize<900
1893
1894 - merpp: Made aware of the new .rep format 200510250. This includes
1895 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1896 the discriminator thresholds (MCameraTD) and the disciminator
1897 delays (MCameraTD). All of them come with the CC report and are therefor
1898 written to the CC tree.
1899
1900 - callisto: fixed a bug in the calculation of the arrival times in
1901 the Digital Filter. They were all shifted by the same amount
1902 fHiGainFirst. This caused an offset in the order of the position of
1903 the left border of the extraction window in the times calculated
1904 from high-gain and from low-gain. The bug effected only the absolute
1905 arrival times. The bug was there since 30.1.2005.
1906
1907 - callisto: Changed the ExtractionWindow for the pulse position check
1908 such that the camera inhomogeneity becomes as less as possible and
1909 comparable to the pulso position check switched off. More details
1910 on the study will be given at our result web-page.
1911
1912 - ganymed: ganymed.rc, ganymed_onoff.rc:
1913 changed to new cuts trained with 1ES1218 and Crab-data
1914 for maximum sigma*log10(excess)
1915
1916 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1917 a new option was implemented to estimate Disp (CalcDisp)
1918
1919 - ganymed: Implemented two new options which allow
1920 to overwrite the default path to search for the sequence files
1921 --ins=/magic/sequences
1922 and where to search for the image data
1923 --ind=/magic/data/star
1924
1925 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1926 dx/dy from the resource file by
1927 MSrcPosCorrect.Dx
1928 MSrcPosCorrect.Dy
1929
1930 - ganymed: fixed reading the source catalog. Only as many chars
1931 as the requested source name had were compared (If a source
1932 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1933 were requested it could happen that the coordinates of
1934 "1ES1218" were read) The source coordinates are now printed
1935 in addition to its name to the logging output.
1936
1937 - ganymed: changed the background fit in the case of a ThetaSq function
1938 from a polynomial to a exponential, this should give a big improvement
1939 for on-only analysis'
1940
1941 - ganymed/sponde: Calculation of the error of single size-/energy-
1942 bins now uses Li/Ma (5) instead of LiMa (17)
1943
1944 - sponde: Added a plot E^2*dN/dE
1945
1946 - sponde: The energy estimator plot should now show values like
1947 they are commonly used.
1948
1949 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1950 (a powerlaw with cutoff didn't work before)
1951
1952
1953
1954 *** Version 0.9.4.2 (2005/10/01)
1955
1956 - general: added new tutorial macro macros/tutorials/threshold.C:
1957 how to calculate the threshold
1958
1959 - general: added a new game. Start it from the interpreter with
1960 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1961 and MagicReversi)
1962
1963 - general: neighbor pixels in MGeoms are now sorted clockwise
1964
1965 - merpp: made aware of new format 20050829-0
1966
1967 - callisto: New scale factors from muon analysis, stored in new
1968 resource file resources/calibration.rc
1969
1970 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1971 the eventloop if something went wrong. This is necessary for the
1972 automatic processing
1973
1974 - callisto: Implemented a new treatment for the time information
1975 developed by S.Ruegamer, this should give much better response than
1976 the old very primitive algorithm. This is especially important
1977 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1978 treatment was buggy! As neighbor pixels to interpolate the
1979 arrival times always the pixels 0 to 5 were taken)
1980
1981 - callisto: In addition to the new treatment of arrival times the
1982 decision of the treatment whether a pixel contains shower
1983 information or not is used to improve the signal interpolation
1984 further. Previously interpolated pixels showed a non-zero signal
1985 do the peak searching signal extractors. Having a signal pixel
1986 beside raised the signal above the cleaning level. Thus the
1987 pixel survived cleaning to often but with a too low mean signal.
1988 By replacing empty pixels with a gaus (mean and rms from the
1989 corresponding Area entries in MPedPhotCam) this effect can
1990 be supressed.
1991
1992 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1993 got lost when the events were stored by the calibration... fixed.
1994 (This was no problem for normal image cleaning because the pixel
1995 content was artificially set to 0 not surviving standard cleaning
1996 algorithm)
1997
1998 - callisto: Fixed a bug which caused the random and peak-search pedestal
1999 extracted with an extractor to be exchanged for the first (roughly)
2000 500 events (*Extractor and *ExtractorRndm).
2001 (They were simply exchanged in callisto.cc) This bug might have been
2002 introduced in Mars 0.9.4 when the order of calculation of the two
2003 types of pedestal in callisto got exchanged. The bug only effects
2004 the first seconds of data of each sequence.
2005
2006 - star: Taking the arrival time of Muons into account the calculation
2007 of the parameters could be made independant of the noise
2008 (pedestal rms). The dependance was due to the bias of the peak search
2009 extractor. Now only a ZA dependamcy is left which is not yet fully
2010 understood.
2011
2012 - ganymed: The sequences were still not sorted correctly in any case,
2013 because they were sorted by the full qualified path name. Now they
2014 are sorted by their sequence number.
2015
2016 - ganymed: new values for the spark-event-cut
2017
2018 - sponde: required missing MEnergyEst from ganymed.root... fixed.
2019
2020
2021
2022 *** Version 0.9.4.1 (2005/08/18)
2023
2024 - callisto: fixed some problems with the calibration in case of
2025 inteleaved events. Therefor the final and some intermediate
2026 fits are skipped which would take place on partly filled #
2027 histograms and gave wrong results or failed completely.
2028
2029 - callisto: If the intermediate finalization of the histograms
2030 calculating the mean charge of the calibration signal fails
2031 it is counted now and printed in PostProcess of MCalibCalcFromPast.
2032
2033 - ganymed: Fixed some bugs which caused problems in On-only mode.
2034 Still the false source plot doesn't give reasonable results.
2035
2036
2037
2038 *** Version 0.9.4 (2005/08/05)
2039
2040 - general: Fixed the ZA binning. It did not correctly fit the
2041 MC binning
2042
2043 - general: Added a class to correct for the missfocussing in
2044 April (MSrcPosCorrect)
2045
2046 - general: Random Forest energy estimator should now work properly
2047
2048 - general: MHCamera now displays the profiles in deg instead of mm
2049
2050 - general: MH::SetPalette offers a lot of new palettes
2051
2052 - general: MHillas - the case of CorrXY==0 is now handled properly
2053
2054 - general: implemented the possibility to change the line and
2055 marker style of a sky-grid drawn by MAstroCatalog
2056
2057 - general: Runs in sequences and datasets are now automatically
2058 ordered (it is assumed that the order of their filenames correctly
2059 represents the order of observations) to ensure correct reading
2060 of the subsystem data
2061
2062 - general: Runs cannot be added to a sequence twice anymore. Also
2063 Sequences cannot be added twice anymore to a dataset.
2064
2065 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2066 It gave wrong results by 1./2pi
2067
2068 - showplot: got a new option to start a root interpreter, too
2069
2070 - mars: now displays a rough estimate of Disp and the third moment
2071
2072 - mars: now displays the event time MTime if available
2073
2074 - mars: show muon parameters graphically
2075
2076 - mars: now the file to open can be given as commandline
2077 argument
2078
2079 - merpp: Added support for new arehucas version >= 200507190
2080 implementing values for three temperature sensors in the
2081 counting house (MCameraAUX) and the name of the HV settings file
2082 (MCameraHV).
2083
2084 - merrp: Also fixed some problems with wrong versions numbers stated
2085 by arehucas and implemented some fixed for old versions (<200407070)
2086
2087 - callisto: MCalibrationHiLoCam can now be printed from its context
2088 menu, eg in the TBrowser
2089
2090 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2091 - 1.39 (MExtractTimeAndChargeSpline)
2092 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2093 This is important mainly for timing studies.
2094
2095 - callisto: Changed limits in MHCalibrationChargeCalc from
2096 - -100.125 to -98 (fgChargeHiGainFirst)
2097 - 1899.875 to 1902. (fgChargeHiGainLast)
2098 - -100.25 to -99 (fgChargeLoGainFirst)
2099 - 899.75 to 901. (fgChargeLoGainLast)
2100 Introduced new limits:
2101 - fgNumLoGainBlackoutLimit: 0.05
2102 - fgLoGainBlackoutLimit: 3.5
2103 - fgLoGainPickupLimit: 3.5
2104
2105 - callisto: The handling of automatic weights for the digital filter
2106 has been improved. There are now new calibration weights special
2107 for Monte Carlo calibrations.
2108
2109 - callisto: Updated Muon scale with latest results (1% difference
2110 for most data, 5% for Mar/Apr'05)
2111
2112 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2113 was saturated and the blackout-events in the low-gain exceed the
2114 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2115 This excludes those pixels which have a saturating high-gain
2116 channel, but the low-gain switch does not switch often enough
2117 to make the distribution reliable.
2118
2119 - callisto: fix a bug counting the number of saturated events. Up to now,
2120 the number of saturated slices was counted (which is one for a not too
2121 high number), but for some (pathological) pixels, many more slices
2122 saturated and produced wrong limits.
2123
2124 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2125 + MCalibrationRelTimeCam.CheckFitResults: Yes
2126 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2127 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2128 + MCalibrationRelTimeCam.CheckOscillations: Yes
2129
2130 - callisto: introduce max. number of events for intercalibration,
2131 the rest gets skipped. Default: 4096
2132 The calibration causes too many un-reliable pixels if more
2133 than about 5000 events are treated (@500 Hz) because of the
2134 mode hopping of the VCSels. However, in the past, some
2135 calibration runs have been taken (erroneously) with more
2136 than 5000 events, especially the intensity scans where
2137 a good precision is needed.
2138
2139 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2140 photo-electrons for the spline extractor by 1-2% (correctly).
2141
2142 - callisto: The intercalibration is now done using a full f-factor
2143 method instead of a simple update. This makes things slower but
2144 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2145 changes.
2146
2147 - callisto: MPedestalY3 now uses the same extraction range as the data
2148 as calculated by MPedestalY2
2149
2150 - callisto: A check of the fraction of allowed unsuitable (10%) and
2151 unreliable (30%) pixels has been addded when the conversion is
2152 calculated from interleaved events
2153
2154 - star: fixed a bug which caused MEffectiveOnTime containers not to
2155 be written. In the worst case they were skipped almost all, in the
2156 best case they were all ok. It depends on how often the new value
2157 was assigned just with an event which was skipped later by another
2158 task
2159
2160 - star: new histograms MHPointing and MHRate
2161
2162 - star: New tab (Currents) displaying the time evolution of the mean
2163 DC currents
2164
2165 - star: New tab (MeanRms) displaying the time volution of the mean
2166 Pedestal Rms
2167
2168 - star: Output now contains MReportStarguider
2169
2170 - star: Improved muon analysis. Due to the absense of a constant
2171 for the gaus fit for arc width and the fact that the arcwidth
2172 plot was a histogram instead of a profile the resulting psf
2173 became pedestal rms dependant
2174
2175 - ganymed: added new plot (MHPhi) for wobble mode as described in
2176 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2177
2178 - ganymed: corrects now (correctly?) for the misspointing in
2179 May/April 05
2180
2181 - ganymed: Two new default templates for ganymed.rc are avilable:
2182 ganymed_onoff.rc and ganymed_wobble.rc
2183
2184 - ganymed: The first version of MFMagicCuts has been released
2185
2186 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2187
2188 - ganymed, sponde: There are two new options to determin the number
2189 of bins for the signal region (NumBinsSignal) and the number of
2190 total bins (NumBinsTotal) in the MHThetaSq histogram
2191
2192 - ganymed: optimized palettes for MHDisp
2193
2194 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2195 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2196 sqrt(2) to large
2197
2198 - ganymed: The false source plot (MHDisp) is now based on Disp
2199 and a background model determined in the first loop is
2200 subtracted
2201
2202 - ganymed: MFMagicCuts are now available in the cvs. The correct
2203 solution for the disp ambiguity problem is now calculated using
2204 the third moment. The third moment cut therefor is skipped.
2205
2206 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2207 already determined by the third moment along the major axis and
2208 so its actual sign is aligned along the major axis of the shower.
2209
2210 - ganymed: If starguider data is available it is taken into account
2211 when calculating the source position. This is especially important
2212 for wobble data at high zenith angles and culmination data.
2213
2214 - ganymed: If available the starguider data is taken into account as
2215 good as it is possible without a starguider calibration. To switch
2216 it off add
2217 MPointingDevCalc.MaxAbsDev: -1
2218 to your ganymed.rc
2219
2220 - sponde: the zenith angle distribution is now weighted instead of
2221 choosen by default. This gurantees higher statistics in the highest
2222 and lowest energy bins. To switch this behaviour off use...
2223
2224 - sponde: now automatically displays the energy threshold
2225
2226
2227
2228 *** Version 0.9.3 (2005/06/03)
2229
2230 - general: MMcEvt now derived from MMcEvtBasic which should
2231 have no influence on compatibility with older camera files
2232
2233 - general: Implemented a new option to MReadReports which allows
2234 to force reading of the first event of some trees (eg. Drive-tree)
2235 before any other tree.
2236
2237 - general: Made a fix to MPointingPosCalc which assumes that the
2238 run-type is real-data if Process is called before ReInit, such
2239 that also the very first Drive-events in a run are treated
2240 correctly.
2241
2242 - shoplot now displays the filename in the title bar of the window
2243
2244 - merpp: new options: --auto-time-start --auto-time-stop which
2245 allow to cut updating with slow-control at the start- or
2246 (previousle --auto-time only allowed: and) stop-time of
2247 the run stored in the runheader.
2248
2249 - callisto: changed default of fgFallTimeHiGain in
2250 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2251 already set as default in callisto_Dec04Jan05.rc
2252
2253 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2254 now changes the filename for new weights automatically for
2255 cosmics, MC and for different calibration colors.
2256
2257 - callisto: a problem with the order of some code cause the
2258 name of the weights file in MPedestalY2 to be ignored.
2259 Wrongly the calibration_UV weights were used instead
2260 of the cosmics weights set in callisto.rc.
2261
2262 - callisto: should allow ct1 pulser data when the color is
2263 explicitly set also for pretty new runs
2264
2265 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2266 to introduce an additional scale factor (should be around 1)
2267 to adapt for slight deviations in different extractors from
2268 the MC calibration. For MC calibrations the scale factor
2269 is fixed to 1
2270
2271 - callisto: MFCosmics should handle very high signals a bit
2272 more accurate now
2273
2274 - callisto: when calculating the mean pedestal rms for different
2275 pixel sizes or sectors also kUnsuitableEvt is now taken into
2276 account - not only kUnsuitableRun
2277
2278 - callisto: '-raw' option is now the default
2279
2280 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2281 This has the advantage that mean values in the calibration (eg
2282 arrival times) are calculated more accuratly.
2283
2284 - callisto: In the resource file callisto_Dec04Jan05.rc
2285 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2286
2287 - callisto: new Hi-/Lo-Gain intercalibration constants
2288 hilocalib_sp1.root and hilocalib_sp1_mc.root
2289
2290 - callisto: changed default for MJPedestalY2.MaxEvents
2291 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2292
2293 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2294 has changed from 9.0 to 6.0. This is necessary to exclude two very
2295 ringing pixels in September which - when kept - destroy the image
2296 cleaning around them (Markus G.)
2297
2298 - callisto: (!) The Muon analysis of all data taken so far has
2299 suggested that different extractors give slightly different
2300 absolute results after calibration, due to there different
2301 handling of the calibration- and cosmics pulse shape. Although
2302 the over all calibration seems to be a bit to pesimistic (or
2303 the MC seems to be a little bit - 3-5% - too much attenuated).
2304 There for correction factors have been introduced which correct
2305 the calibration constants by
2306 0.956937799 for Digital Filter (callisto.rc)
2307 and
2308 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2309 calibration. The main advantage is, that both data types can
2310 be easily analysed together and compared to the same MC sample.
2311 The factors are choosen such, that the reference is now a
2312 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2313
2314 - star: fixed a bug which caused the first bin of the histograms
2315 vs time to disapear in PostProcess. This gave wrong results
2316 on the screen. The output and all following programs not
2317 directly accessing the histograms haven't been affected
2318
2319 - star, ganymed: Made sure that always the first Drive-tree event
2320 is read and Processed before the first data event was read.
2321
2322 - ganymed: implemented the possibility to replace the standard
2323 false source plot with a different one. For example: If
2324 you want to use a Disp based FS plot use the resource:
2325 NameHistFS: MHDisp
2326 For details about the requirements of these plots look
2327 at the corresponding classes
2328
2329 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2330 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2331 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2332 case MAlphaFitter is setup correctly. For On-Only optimization
2333 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2334 RunOn() instead of Run(). For energy estimation MJOptimize
2335 has been replaced by MJOptimizeEnergy
2336
2337 - sponde: The input MC spectrum can now be weighted to fake a
2338 different spectrum. This is done via MMcSpectrumWeight. For
2339 more details see the class description and sponde.rc
2340
2341 - sponde: The paremeter comparsion plots are not scaled by
2342 their entries anymore. Instead the MC plot is scaled by using
2343 the result spectrum of the analysis. If the input MC spectrum
2344 and the result spectrum has different slopes the absolut
2345 normalization is normally wrong.
2346
2347
2348
2349 *** Version 0.9.2 (2005/05/20)
2350
2351 - general: Changed the default paths for calibrated data and image
2352 files. (The implemented access to these files doesn't yet exist)
2353
2354 - general: support for MRunIter has been removed from the job classes
2355 (use the setter functions of MSeqeunce instead)
2356
2357 - general: ProcessFile has been renamed to Process in all job classes,
2358 because ProcessFile is missleading
2359
2360 - general: The storage of the palette in MHCamera is now possible
2361
2362 - general: new bits describing unsuitable and unreliable pixels have
2363 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2364 kDeadPedestalRms, kFluctuatingArrivalTimes
2365
2366 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2367 versions newer than V200404070
2368
2369 - general: support for cc file versions newer than V200504130. Added
2370 support for active loads (MCameraActiveLoad) and central pixel
2371 (MCameraCentralPixel)
2372
2373 - general: added new histograms for image parameters versus size
2374 (MHVsSize)
2375
2376 - general: The eventloop now automatically calls PrintStatistics
2377
2378 - Status Display: Improved support for printing:
2379 + A default can now be set in .rootrc (for more details see
2380 MStatusDisplay::PrintPS)
2381 + A print dialog is opened so that printer and command line
2382 can be canged
2383
2384 - showlog: improved such that it handles different verbosity levels
2385 more accurate now. This mean you can suppress output when
2386 using showlog.
2387
2388 - showplot: improved
2389 + The new graphics formats have been implemented
2390 (pdf, svg, png, jpg and xpm)
2391 + Implemented an interface for printing. Because you can change
2392 the printing command from the command line you can use all
2393 the nice postscript tool. To print a booklet for example call:
2394 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2395 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2396 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2397
2398 - callisto: fixed a bug in the recognition of the calibration bit
2399 pattern. Concerns only intensity calibration. (The strength of the
2400 intensity has been updated in some cases)
2401
2402 - callisto: add a filter against PIN Diode events when running over
2403 calibration runs since some of the recent calibration runs have
2404 been taken with Pin Diode.
2405
2406 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2407 39943, 44833 in the calibration (MCalibColorSet)
2408
2409 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2410 been set to 1e-18 in callisto_Dec04_Jan05.rc
2411
2412 - callisto: in callisto_Dec04Jan05.rc: set value for
2413 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2414 statistics for the calculation of the mean pulse time
2415 of the cosmisc
2416
2417 - callisto: the charge limit in the calibration has been raised
2418 from 2.5 to 4.5
2419
2420 - callisto: new setup read from callisto.rc
2421 + MCalibCalcFromPast.fNumEventsDump
2422 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2423 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2424
2425 - callisto: MExtractTimeAndChargeSpline extractor:
2426 + The integration ranges were shifted by 0.2 FADC slices to the right.
2427 + unreliable handling of floating point values caused different
2428 results on different platform or with different compiler options:
2429 The new algorithm is numerically exact and more accurate because
2430 it doesn't calculate the integration position by multiple times
2431 adding the step-size (which results in numerical uncertanties
2432 exspecially if multiplied with large numbers)
2433 + A lot of fixes have been introduced which effects integrating the
2434 spline at the edges of the valid range. In this case any memory
2435 was randomly accessed. This behaviour can be tested replacing
2436 all MArrayF by TArrayF which perform a range check (but of course
2437 they are a lot slower)
2438 ! No result obtained with the Spline before can be trusted! Due to
2439 random memory access it might by completely random!
2440
2441 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2442 + extraction range in the high gain to 4.
2443 + weights file to cosmics_weights46.dat
2444
2445 - callisto:
2446 + introduce the check for fluctuating arrival times.
2447 + set charge limit to from 2.5 to 4.5
2448 + introduce asymmetric exclusion due to "deviating number of phes":
2449 Default: -9.0 +4.5
2450 + make deviating number of phes unsuitable (see David's findings).
2451
2452 - callisto: fixed the display of unsuitable pixels. The old change
2453 to a real profile in MHCamera broke it.
2454
2455 - callisto: The cosmics filter is used in MJCalibration now
2456 independant of the pulser color (formaly it was used only for
2457 CT1-pulser data). The threshold of number of max empty pixels
2458 has been raised from 2% to 5% in MJCalibration. The maximum
2459 fraction of rejected event is 50% otherwise the calibration has
2460 failed. The filter now ignores unsuitable pixels.
2461 Setup the filter from callisto.rc using "ContCosmics"
2462 (see MFCosmics::ReadEnv)
2463
2464 - callisto: changed default for fgOffsetFromLogain back
2465 from -2.8 to -1.8 in digital filter.
2466
2467 - callisto: for the common extractors
2468 + MExtractFixedWindow
2469 * MExtractTimeAndChargeSlidingWindow
2470 * MExtractTimeAndChargeSpline
2471 * MExtractTimeAndChargeDigitalFilter
2472 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2473 and fResolutionPerPheLoGain
2474
2475 - callisto: Updated the hi-/lo-gain intercalibration constants
2476 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2477 hilocalib_df6.root
2478
2479 - callisto: The default lo-gain extraction window for the
2480 MExtractTimeAndChargeSlidingWindow extractor has been increased
2481 from 6 to 8 to take the stretch of the pusle into account
2482
2483 - callisto (!!!): fixed an important bug in the setting of the
2484 incoming pedestal pointer to the signal extractor extracting
2485 pedestals. This bug caused the pedestals not to be subtracted
2486 correctly in the calibration afterwards. The effect was about 10%
2487 too high conversion factors for the digital filter and the spline
2488 and more than 40% for the sliding window.
2489 The bug existed since end of February! (Markus G.)
2490
2491 - star: added muon support to star. A new tab "MHMuonPar" is
2492 displayed. The lower right plot is an estimate of the point spread
2493 function. A reference value is displayed. To get the real PSF
2494 you must compare with MC. The setup for the muon analysis
2495 is done in star.rc. More informations can be found in
2496 MHSingleMuon and MHCalibParCalc
2497
2498 - star: The weather data is now displayed in star
2499
2500 - star: MEventRateCalc handles the calculation of the event rate more
2501 accurate now in case of the start of a new run inside a sequence
2502
2503 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2504 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2505 changed only minimally
2506
2507 - ganymed: (MJCut and MJOptimize) now displayes the number of
2508 excess events versus size. The energy estimation is done in
2509 MJSpectrum (sponde)
2510
2511 - ganymed: got support for using other variables than Alpha, eg. Theta.
2512 Therefor you need a class deriving from MHAlpha which supports
2513 this variable (one is already existing: MHTheta, which is now the
2514 default in ganymed). It is setup through ganymed.rc
2515
2516 - added a full featured spectrum program (sponde) which reads
2517 ganymed output and monte carlos and compiles a spectrum
2518
2519
2520
2521 *** Version 0.9.1 (2005/04/14)
2522
2523 - Fix bug on the arrival time reconstruction when using Digital
2524 Filter (in some marginal cases (10%) times were reconstructed shifted
2525 by 0.2 slices)
2526
2527 - all executables now return 2 where in previous versions -1 has
2528 been returned (gave problems with shell-scripts)
2529
2530 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2531 also done with a intercalibration input file
2532
2533 - a bug in the time fine adjustment of the digital filter has been fixed
2534
2535 - a lot of small fixes to calling TPad::Divide with a margin==0
2536
2537 - MStatusDisplay now shows the memory usage
2538
2539 - added a memory leak statistic after the eventloop
2540
2541 - MHadronness replaced by MParameterD
2542
2543 - MEnergyEst replaced by MParameterD
2544
2545 - wobble mode can now be switched on from the data-set
2546
2547 - switched on bad pixel detection for a pedestal level
2548 which is more than 5 times the variance
2549
2550 - Fixed default paths to be correct for the new data center
2551
2552 - Fixed handling of drive data. The pointing position in now
2553 copied to MPointingPos inside star for real and MC events
2554
2555 - made sure, that the sequences in a dataset are sorted by
2556 their number to ensure the correct synchronization
2557
2558 - added all resource files necessary to handle spline extraction
2559 of signal for the late 2004 and the early 2005 data
2560
2561 - update the reference lines for the december data
2562
2563 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2564 This is important for the Dec. and Jan. data where the calibration
2565 pulse position changes much.
2566
2567 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2568 filter. This corrects only an defective extraction of the MC at
2569 low-gain signals lower than 90 phes.
2570
2571 - fixed some slowdown in calibrating data with interleaved events from
2572 Jan and Dec. As a workaround made the pretty palette the default.
2573 The inverse Deep Blue Sea has a bug which slows down long calibration
2574 runs a lot.
2575
2576 - implemented new values from new starguider report as defined
2577 in TDAS00-07 V7.1 (eg SkyBrighness)
2578
2579 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2580 in starguider report (If you merpp the same reports with this version
2581 you'll get the correct units (arcmin) but a different result
2582 than with old versions (wrong units))
2583
2584 - Now the status display can also write PNG, JPEG and XPM (other file
2585 formats are still unsupported by root)
2586
2587 - added a lot of scripts and macros in directory datacenter used
2588 for automatic processing
2589
2590
2591
2592 *** Version 0.9 (2005/03/23)
2593
2594 - Calibration is now done autmatically into photo-electrons like
2595 decided by the Collaboration Board
2596
2597 - Reference lines in the display can be read from resource file
2598
2599 - Interlaced calibration events can be handled by callisto
2600
2601 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2602 and applied in callisto.
2603
2604 - class MJCalibTest can be called by callisto
2605
2606 - callisto can now run with three data types: rawdata, rootdata, MC
2607
2608 - added two classes mreport/MReportStarguider.cc and
2609 mreport/MReportStarguider.h for implementing starguider-data
2610
2611 - the output of merpp-update now contains starguider information:
2612 MReportStarguider and MTimeStarguider
2613
2614 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2615 values were lower than they should. This was more visible for high
2616 energy (Size) events.
2617
2618 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2619
2620 - added a new loop to callisto to support the correct extraction of
2621 the pedestal and pedestal rms through the signal extractor
2622
2623 - added class to perform fourier tranformation of a hexagonal structure
2624 (MHexagonalFT)
2625
2626 - added class to perform fourier tranformation of a hexagonal structure
2627 in a tasklist (MHexagonalFTCalc) example: hft.C
2628
2629 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2630 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2631 small pixels, example: extendcam.C
2632
2633 - added possibility to write data to memory (TTree) using MWriteRootFile
2634
2635 - added possibility to read a TTree stored only in memory by MReadTree
2636
2637 - new classes to deal with the interleaved calibration events:
2638 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2639
2640 - implemented filters to callisto to skip calibration events
2641
2642 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2643 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2644 the slices by statistics
2645 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2646 signal extractor without randomization
2647 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2648 with the signal extractor with randomization (extraction window is
2649 randomly fixed)
2650 The three kind of pedestal is not yet implemented (for speed reasons) as
2651 long as nobody really needs it:
2652 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2653 extracted with the signal extractor with randomization
2654
2655 - callisto now finds the pulse position in the data automatically
2656
2657 - implemented data reduction in calibrated data by reducing the precision
2658 of the stored floating point values (pedestal, rms and signal) to
2659 roughly 0.5%
2660
2661 - fixed showplot to make file format conversion (eg. converting a
2662 status display stored in a root file into a postscript file) in
2663 batch mode possible:
2664 showplot -b --save-as-ps[=outfile.ps] infile.root
2665
2666 - Allow class names as part of filter rules, eg
2667 (MFSupercuts) && (MHillas.fSize>100)
2668
2669 - fixed a lot of stuff to allow all programs to process MonteCarlo
2670 camera files.
2671
2672 - enhanced possibility to debug reading of resource file
2673
2674 - MDataChain should handle priorities of operator more
2675 accurate now
2676
2677 - completely revised the container in which the signal is stored
2678 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2679 * the new implementation is faster and
2680 * needs less storage space
2681
2682 - FIRST version which can process Monte Carlos through the
2683 whole chain of programs (callisto, star, etc)
2684
2685 - implemented new image parameters for the border length of
2686 the shower image (MNewImagePar2)
2687
2688 - implemented wobble-mode in ganymed
2689
2690 - new class (MJOptimize) taking care of all optimization processes
2691
2692
2693
2694 *** Version 0.8.6 (2004/10/05)
2695
2696 - New combined signal and time extractor
2697 MExtractTimeAndChargeDigitalFilter
2698
2699 - The Report for the trigger section in the CC run summary has been
2700 updated, and now the IPRs (Individual Pixel Rates) are available.
2701
2702 - new macros for database interaction: filldotrun.C, filldotrbk.C
2703
2704 - added new program which can convert colored output which was redirected
2705 into a file back into colored text (for example to display it with
2706 more): showlog
2707
2708 - added new program to display an MStatusArray of plots (stored with
2709 MStatusDisplay) from a file: showplot
2710
2711 - Added support for Sequences (MSequence). Sequences are blocks of run
2712 files containing the same calibration and belonging to the same
2713 source
2714
2715 - Added a new task (MTaskEnv) which can be used in setup files to switch
2716 between different tasks (for example to choose a signal extractor)
2717
2718 - Implemented automatic file splitting in MWriteRootFile
2719
2720 - After image cleaning an island index is assigned to all used pixels.
2721 The index corresponds to the order of the islands in size.
2722
2723 - added a cleaning which takes signal height _and_ arrival time into
2724 account: probability cleaning (for more details see MImgCleanStd)
2725
2726 - added a cleaning which takes takes the absolute number of photons
2727 times the area ratio as cleaning level
2728 (for more details see MImgCleanStd)
2729
2730 - Changed calculation of image parameters such, that it can be done
2731 for all used pixels or the pixels with a defined island index only
2732
2733 - implemented new image parameters displaying the number of islands,
2734 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2735
2736 - event display in executable changed to support also calibrated files
2737 (done with MJCalibrateSignal)
2738
2739 - added program doing the calibration and the signal extraction
2740 and signal calibration: callisto Most part of the setup is done
2741 by a resource file: callisto.rc
2742
2743 - implemented support for pixels with negative IDs (Raw file format
2744 version 4)
2745
2746 - implemented an new option in merpp (--auto-time) to get the time
2747 range for cc and/or caco data from the run header of the raw data
2748
2749 - New star-program (star and MJStar). Taking calibrated data from
2750 callisto/MJCalibrateSignal as input. The setup is done through
2751 a resource file: star.rc
2752
2753 - Added possibility to setup the eventloop in the mars-executable
2754 Camera Display by a resource file: mars.rc
2755
2756 - The the mars-executable Camera Display can now also read
2757 calibrated data files written by callisto/MJCalibrateSignal
2758
2759 - Added a new class which can calculate the source position in
2760 the camera from a pointing model known to be correct and
2761 the pointing model used for observations (MSrcPosFromModel)
2762
2763 - added a new version of the class calculating the effective on-time
2764 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2765 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2766 MHTimeDiffTheta.
2767
2768 - added the possibility to count how often a signal is above (or
2769 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2770 can replace MHTriggerLvl0)
2771
2772 - added ore convinient ways to set the axis-titles of your histograms
2773 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2774 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2775
2776
2777
2778 *** Version 0.8.5 (2004/08/06)
2779
2780 - new Signal Extractors: MExtractFixedWindowSpline
2781 and MExtractAmplitudeSpline
2782
2783 - implementes interleave in merpp to be able to merpp parts of a file
2784
2785 - implemented force-functionality to merpp
2786
2787 - star display to display star catalogs (MAstroCatalog)
2788
2789 - star display to 'mirror' stars to the camera (MAstroCamera)
2790
2791 - implemented a new cleaning option which allows cleaning scaled with
2792 the real ratio of the rms depending on the pixel size, not only the
2793 square root of the pixelsize (MImgCleanStd, MCameraData)
2794
2795 - removed obsolete MBlind* classes
2796
2797 - Signal extractor taking the AB flag into account implemented (this makes
2798 an odd number of slices for signal extraction possible
2799 (MExtractSignalABcorr)
2800
2801 - implemented a class extracting the pedestal from the raw-data (events)
2802 itself using empty lo-gain (MpedCalcFromLoGain)
2803
2804 - Added mean values to MPedPhotCam
2805
2806 - Added Makefile for Darwin (this OS is NOT officially supported!)
2807
2808
2809
2810 *** Version 0.8.4 (2004/04/19)
2811
2812 - new fast arrival time extractor using cubic splines:
2813 MExtractTimeFastSpline
2814
2815 - implementes multi-argument support in MDataChain
2816 ("pow(a, b)")
2817
2818 - implemented double reference support in MDataChain
2819 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2820
2821 - added support in MF for expressiond like
2822 "MHillas.fWidth<2*<MHillas.fLength"
2823
2824 - MDataChain is now able to support variables like [0], [1], ...
2825 which can be used in fit functions as parameters. The interface
2826 is implemented through the new virtual function
2827 MParContainer::SetVariables
2828
2829 - added new class MArrivalTimeCam/MArrivalTimePix:
2830 Storage containers to hold the ArrivalTime of the camera/pixel
2831
2832 - added new classes for the calibration of relative arrival times:
2833 MCalibrationRelTimePix and MCalibrationRelTimeCam
2834
2835 - added new classes to extract the signal of the blind pixel and the
2836 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2837
2838 - added new classes for the bad-pixels treatment (MBadPixels*)
2839 which are more powerfull than the old ones (MBlindPixel*)
2840 and will replace them.
2841
2842 - added filter against cosmics: MFCosmics
2843
2844 - added new class MArrivalTimeCalc2:
2845 Calculates the arrival time as the signal weighted mean of the time
2846 slices in the maximum window
2847
2848 - added a new macro call pointspreadfucntion.C that fits with a 2D
2849 gaussian the DC spot for an star. It gives you the RMS of
2850 the PSF and the center of the star, very useful for misspointing
2851 studies.
2852
2853 - added support for multi-telescope camera files. Added classes
2854 MStereoCalc and MStereoPar, classes to calculate and store shower
2855 parameters calculated from the data of two telescopes, for the MC
2856 studies regarding the MAGIC clone.
2857
2858 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2859 MC data calibrated in photons instead of ADC counts.
2860
2861 - added three macros to show the calibration and analysis chain of
2862 MC data. The macro starmc.C does both calibration and analysis, producing
2863 an output containing Hillas parameters for each event. The macro
2864 mccalibrate.C does just the calibration and writes out a file containing
2865 pixel information in photons instead of FADC data. The macro starmc2.C
2866 reads in such a file and produces an output with Hillas parameters.
2867
2868 - added MPedPhotCalc to compute pedestals in units of photons, see
2869 macro pedphotcalc.C
2870
2871 - added all class to perform the calibration, see macro calibration.C
2872
2873 - added class MFFT to perform Fast Fourier Transforms
2874
2875 - added class MSimulatedAnnealing to perform simulated annealing
2876 minimizations
2877
2878 - added new macro bootcampstandardanalysis.C which holds the skeleton
2879 of the analysis chain discussed in the december bootcamp.
2880
2881 - added support for DAQ raw data file format V2
2882
2883 - implemented an arbitrary time stamp for the events from raw-data
2884 files with file version<3. It is calculated from the run number,
2885 the date of start and the FADC clock tick from the first module
2886
2887 - implemented the correct decoding of the event time-stamp
2888 coming from the DAQ for raw-data files with file-version>2
2889
2890 - added a new classes storing the pedestals in units of photons:
2891 MPedPhotPix, MPedPhotCam
2892
2893 - added support for DC current files from the camera control
2894
2895 - added support for start- and stop-time when merpping report files
2896
2897 - added MReportCC storing the weather data from the CC-REPORT
2898
2899 - added class to fill trainings and test matrices (MTFillMatrix)
2900
2901 - added a filter performing a software trigger (MFSoftwareTrigger)
2902
2903 - Added classes to perform parts of the standard analysis (Jobs):
2904 + MJPedestals
2905 + MJCalibration
2906 + MJExtractSignal
2907 Note: All of them are preliminary!
2908
2909 - Added Iterator to iterate over files giving only the run-number
2910
2911 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2912 the evolution of a sector vs time
2913
2914
2915
2916 *** Version 0.8.3 (2003/12/05)
2917
2918 - adapted Random Forest classes to allow the use with MC
2919 multi-telescope files which can be produced with the coming
2920 camera version 0.7.
2921
2922 - added classes to read and interprete central control report files
2923 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2924
2925 - enhanced merpp (the executable) to support .raw and .rep files.
2926
2927 - added classes for light calibration (MCalibration* and
2928 MHCalibration*) by Markus Gaug. Further work has to be and will
2929 be done soon.
2930
2931 - Added a preliminary 'synchronizer' (MReadReports) which will
2932 replace MReadMarsFile as soon as it is finished.
2933
2934 - Added a tutorial macro demonstrating how report files are merpped
2935 and how they can be read from the root file in the correct order
2936 of time (readrep.C)
2937
2938 - Added a generalized histogram (similar to MH3) called MVsTime
2939 which allows to plot variables (or rules - MDataChain - of
2940 variables) vs time. For an example have a look at tempvstime.C.
2941
2942 - Changed the name of the event trees:
2943 + Events --> Events
2944 + PedEvents --> Pedestals
2945 + CalEvents --> Calibration
2946
2947 - changed name of MTime in the event trees from MRawEvtTime to MTime
2948
2949 - added displaying the sector indices to the mars event display
2950
2951 - Magic Online Analysis (MOnA) implemented in a first version
2952 (see mona.cc, MOnlineDump and MOnlineDisplay)
2953
2954 - added classes to calculate event rate
2955 (preliminary: MEventRateCalc, MEventRate)
2956
2957 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2958
2959 - added classes dealing with the telescope pointing position (MPointing*)
2960
2961 - implemented the 'final' Mars time stamp based on some experiences with
2962 the new 'Synchonizer'
2963
2964
2965
2966 *** Version 0.8.2 (2003/11/10)
2967
2968 - accelerated standard analysis by a factor of 6-8 ...
2969 + doing precalculations in MGeomCam for the pixel area ratio
2970 + creating a look up table for the single pixels in MCerPhotEvt
2971
2972 - added task to calculates weights in case you want to 'change'
2973 the energy spectrum of a monte carlo file
2974 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2975
2976 - added a new executable star which implements the
2977 star.C macro as precompiled executable. Currently a flexible
2978 setup is not possible, but a 'input card' setup will follow.
2979
2980 - Starting to implement Multi-Telescope-Support based on the
2981 upcomming camera version 0.7. The base for a general support
2982 is implemented and the star-functionality is proven to work.
2983
2984 - Replaced Event-Display in and Camera-Display in the Mars GUI
2985 executable by a more convinient display base on MStatusDisplay.
2986
2987 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2988
2989
2990
2991 *** Version 0.8.1 (2003/10/20)
2992
2993 - added signal subtraction for pure on data by means of fitting
2994 the background in the off region or by performing a combined
2995 signal/background fit. Provides necessary histograms for
2996 obtaining energy spectra and a light curve.
2997
2998 - added classes to perform and study the selection of the
2999 2nd Level Trigger on MC data (example in triglvl2.C macro)
3000
3001 - added pedestal calculation
3002
3003 - implemented "democratic cleaning" (tail cut value proportional
3004 to pixel area) according to Wolfgang's suggestion.
3005
3006 - added Sigmabar treatment (calculation and basic histogramming)
3007
3008 - added basic routines to apply padding
3009
3010 - added first implementation of MARS-based source visibility plotter
3011 (needs to be linked against slalib, preliminary version)
3012
3013 - enhanced functionality of data chains: random numbers, conversion
3014 functions and access to MHMatrix objects
3015
3016 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
3017 numbers under certain circumstances (runs with 0 events included)
3018
3019 - fixed a bug in the general filter MF (didn't work on some systems
3020 at all)
3021
3022 - fixed a bug in chaining files, which caused the analysis to crash or
3023 ignore files
3024
3025 - implemented more geometry classes describing the parameters used
3026 to simulate the PMT camera
3027
3028 - added new Monte Carlo classes containing the setup of the different
3029 programs in the MC chain.
3030
3031 - added a (preliminary) general task to evaluate chi-square of a given
3032 parameter in an eventloop.
3033
3034 - first implementation of a container describing the observatory
3035 location (Long, Lat, etc)
3036
3037 - added Random Forest - method for g/h-separation
3038
3039 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3040 (this means, that it is compiling, but not yet fully tested)
3041
3042 - added a new status display which can show the present status
3043 of histograms while an eventloop is running (MStatusDisplay,
3044 an example can be found at status.C)
3045
3046 - reorganized directories:
3047 classes describing the image --> mimage
3048 classes containing Monte Carlo Histograms --> mhistmc
3049 classes for Random Forest method --> mranforest
3050
3051 - added (event-)weights to fill histograms
3052
3053 - colors in logging output to screen
3054
3055 - changes to the Image Parameter declaration:
3056 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3057 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3058 + MHillasExt now derives from MParContainer instead of MHillas
3059 --> Files written with the old definition are more or less unreadable
3060
3061 - reading of reflector files
3062
3063 - display data from reflector files in the camera
3064
3065 - implemented currents (and display them in the camera)
3066
3067 - logarithmic scale in camera
3068
3069 - added class to iterate through directory contents (MDirIter)
3070
3071
3072
3073 *** Version 0.8 (2002/11/18)
3074
3075 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3076
3077 - corrected 48(!) wrong entries in the Next Neighbor table of the
3078 Magic Camera (all in the inner part of the outer ring, mostly
3079 missing a single NN)
3080
3081 - Fixed a bug in the table describing the Next Neighbours of the
3082 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3083 have any neighbour)
3084
3085 - changed trigrate.C: now it calculates the pure NSB triggers from
3086 a camera file (generated with no showers), so there is no need
3087 to introduce them by hand in the BgR array (for more details
3088 please ask Abelardo)
3089
3090 - added MHHadronness (and MHadronness) as a general facility to evaluate
3091 the quality of a gamma-hadron seperation method
3092
3093 - changed MWriteAsciiFile to accept rules (MDataChain)
3094
3095 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3096 must be replaced by calles to MWriteAsciiFile::AddColumn and
3097 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3098 changed.
3099
3100 - Implemented generalized event-matrices (one row per event)
3101 (MHMatrix)
3102
3103 - implemented the one dimensional composite probabilities
3104 (MHCompProb, MCompProbCalc, comprob.C)
3105
3106 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3107 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3108
3109 - Added a camera display displaying the pixel numbers to the
3110 event display gui.
3111
3112 - Added Monte Carlo Informations to event display gui
3113
3114 - Changed the camera display to display the pixel numbering
3115
3116 - Added three buttons to the camera display to change the palette
3117
3118 - Added the number of used and core pixels after image cleaning
3119 to MHillas
3120
3121 - Changed the algorithm used in MHillas according to TDAS 02-03
3122
3123 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3124
3125 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3126
3127 - Added fCosDeltaAlpha to MHillasSrc
3128
3129 - The numbers of photons used to calculate fConc and fConc1 in
3130 MHillasExt are now scaled with the pixel size, so that one get
3131 a four times smaller value for the bigger pixels in the outer ring.
3132
3133 - added new task to smooth the camera contents (MCameraSmooth)
3134
3135 - added possibility to use interpolated pixel values for blind pixels
3136 instead of removing it completely from the analysis
3137
3138 - Implemented the possibility to save the whole eventloop with
3139 its setup to a file. This information can be read and from
3140 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3141 and MEvtLoop::MakeMacro. If you find something not working, please
3142 report - this stuff is still in a beta phase.
3143
3144 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3145 file having crab starfield, but also for all following files - fixed
3146
3147 - MTaskList::PrintStatistics can now be instructud to print also the
3148 title, too: use PrintStatistics(0, kTRUE)
3149
3150 - Changed the image cleaning so that pixels with to many 'used'
3151 neighbors are left used (to get rid of 'holes' in events)
3152
3153 - Introduced more output to the camera displays
3154
3155 - Added an array of histograms (eg one hist per run), MHArray
3156
3157 - Added a _preliminary_ version of the reader for CT1 PreProc files
3158 (MCT1ReadPreProc)
3159
3160 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3161 (thanks to Raquel)
3162
3163 - added the first energy estimator (MEnergyEstParam, estimate.C,
3164 estfit.C) using a parametrization
3165
3166 - Added some new Monte Carlo paremeter containers used to store
3167 setup information from the MC chain (MMcConfigRunHeader,
3168 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3169
3170
3171
3172 *** Version 0.7 (2002/04/30)
3173
3174 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3175 the pedestal mean value was saved incorrectly. For files from
3176 this versions we substract 0.5 from the pedestal mean.
3177 WARNING: This may effect your results, so don't wonder...
3178
3179 - First implementation of an algorithm using only triggered events
3180 for the collection area calculation
3181
3182 - Ascii Output can now also be used for parameter containers which
3183 doesn't overload MParCointainer::AsciiWrite
3184
3185 - The Ascii Output is now also capable of writing single data members
3186 of one container
3187
3188 - You are now able to change the order of the values written to the
3189 ascii file
3190
3191 - You can now specify a conversion factor for each data member written
3192 to an ascii file. This may be usefull to change the units of the
3193 data member (eg. degrees instead of millimeters in case of the
3194 hillas parameters)
3195
3196 - Replaced old MHillas by a new structure which allows you to extend
3197 the parameters stored in MHillas very easily:
3198 see MHillas and MHillasExt
3199
3200 - Added classes to handle source dependancy of image parameters:
3201 see MHillasSrc
3202
3203 - Added container (MBinning) to have a standard input for the binning
3204 in different histograms (eg. the Energy bins should be the same in
3205 all histograms)
3206
3207 - Changed Hillas histograms from mm to deg
3208
3209 - Added the flexible binning to the hillas histograms
3210
3211 - Added a filter for the alpha parameter (MFAlpha)
3212
3213 - It is now possible to write single data members of a class object to
3214 an output stream instead of the whole container only
3215
3216 - Added a generalized filter for a data member:
3217 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3218
3219 - Added a generalized Filter parser for more difficult filter rules
3220 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3221
3222 - Added new Monte Carlo histograms:
3223 MHMcEnergyImpact and MHMcEfficiency
3224
3225 - Added many new histograms needed for the flux calculation.
3226
3227 - Added a generalized histograms which can fill and show up to three
3228 data members in either a one-, two- or three-dimensional histogram, eg:
3229 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3230
3231 - Added:
3232 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3233 * calculation of <Theta> as a function of time (MHThetabarTime)
3234 they are needed in the flux calculation in
3235 order to select for a given bin in Theta (or time) the appropriate
3236 effective collection area, which is assumed to be given as a function
3237 of Theta and the true energy
3238
3239 - Added calculation of the migration matrix in the energy
3240 (MHMcEnergyMigration):
3241 the migration matrix describes the migration from the true (E_true)
3242 to the estimated energy (E_est); it is needed to determine the
3243 distribution of E_true from the measured distribution of E_est
3244 by unfolding
3245
3246 - changed the color palette in the camera display to DeapSea.
3247
3248
3249
3250 *** Version 0.6 (2002/01/15)
3251
3252 - Introduce the option of disable pixels (MBlindPixels and
3253 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3254 able to deal with Star Field NSB.
3255
3256 - Fixed a bug in the pedestals substraction
3257
3258 - Introduced verbosity levels
3259
3260 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3261
3262 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3263 work correctly (thanks to Abelardo)
3264
3265 - Introduced correct treatment of the diffuse Night Sky Background
3266 and NSB (MMcPedestalNSB)
3267
3268 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3269
3270 - Introduced MMcRunHeaders which contains monte carlo run informations
3271
3272 - Added a 'Print'-Task (MPrint) which calls the Print function
3273 of a parameter container for each event
3274
3275 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3276
3277 - changes to be more efficient with root 3.02/06
3278
3279 - root 3.02/06 fixes:
3280 + the memory leak when reading MRawEvtData
3281 + loosing more time than necessary to update the progress bar
3282
3283 - MWriteAsciiFile is now capable of writing more than one container
3284 in a line. For example: To be able to write Monte Carlo and
3285 Hillas values (energy and alpha) in one line.
3286
3287
3288
3289 *** Version 0.5 (2001/11/06)
3290
3291 - Added new GUI functionality (Analysis)
3292
3293 - Added a camera display to be able to display events in the camera
3294 together with the calculated hillas ellipse
3295
3296 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3297 object at any state of the analysis, so that the output are several
3298 states
3299
3300 - Fixed a bug in the collection area error calculation
3301 (Thanks to Ciro and Abelardo)
3302
3303 - Fixed a bug which causes merpp to crash in some environments
3304
3305 - Implemented auto enabling scheme for Branches to speed up reading
3306 a lot (see MReadTree and MTask)
3307
3308 - Fixed a bug in the Histogram classes which caused histograms to
3309 be written to a file by MWriteRootFile without request
3310
3311 - changed the object I/O from the old stylish root I/O to the new
3312 'auto evolution scheme' This was done only for classes which are not
3313 yet used in Monte Carlo files, so that these files are still readable.
3314
3315 - Added support for a progress bar in MEvtLoop and MReadTree
3316 (see the Analysis Window in Mars for an example)
3317
3318 - Fixed a bug in the package creation which disturbed the conversion
3319 between a mars version unpacked from a tar file and the repository.
3320
3321 - Changed the code to writer merpped (converted into root format)
3322 raw files, to get faster (around 10%)
3323
3324
3325
3326 *** Version 0.4 (2001/09/20)
3327
3328 - This release is made to compile on a root version >= 3.00
3329
3330 - Fixed a bug which causes MReadTree to read the first file only
3331
3332 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3333
3334 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3335
3336 - Added a task to write several container to a root file (MWriteRootFile)
3337
3338 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3339
3340 - Added calculation of the collection area (MMcCollectionAreaCalc)
3341
3342 - fixed some bugs in the Hillas calculation
3343
3344 - added filters to be able to control the task execution dependent on
3345 a parameter (for example: the number of level 1 triggers in a MC-file)
3346
3347
3348
3349 *** Version 0.3 (2001/04/23)
3350
3351 - Many demo macros added
3352
3353 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3354
3355 - Hillas Calculation added
3356
3357 - Standard image cleaning available
3358
3359 - MReadTree is now able to handle more than one file
3360 (Remark: of the same structure)
3361
3362 - Now we are able to display events in a first version of the
3363 Camera event display. To do this we must run the macro
3364 "macros/readCT1.C" to read data from CT1.
3365
3366
3367
3368 *** Version 0.2 (2001/01/24)
3369
3370 - First Implementation of a Gui to read the raw data. Start the
3371 gui with the command mars.
3372
3373
3374
3375 *** Version 0.1 (2000/12/20)
3376
3377 - First official release 0.1
3378
3379 - Changes:
3380
3381 + changed calling style of MRawPixelIterator from do...while to
3382 while-loop
Note: See TracBrowser for help on using the repository browser.