1 -*-*- END -*-*-
2
3 *** Version <cvs>
4
5 - merpp: better handling of problems with the TH, TD part of the
6 CC-REPORT for files older than 200507190 and 200412210
7 respectively
8
9 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
10
11 - merpp: implementd latest changes in starguider reports (sinc 9th May)
12
13 - star: Show also the number of stars correlated correctly by the
14 starguider
15
16 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
17 than one off-source region in wobble-mode. To use it add the following to
18 your ganymed_wobble.rc:
19 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
20 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
21 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
22 + Cut1.ThetaCut: None
23 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
24
25
26
27 *** Version 0.9.5.1 (2006/05/05)
28
29 - general: Added a new option "zdiff" to the Makefile which runs
30 "cvs diff" as "make diff" would do, but with compression
31
32 - general: accelerated MTFillMatrix (used for eample in all training
33 and optimization macros) by skipping some obsolete calles in the
34 eventloop the first and second loop could be accelerated by ~20%
35
36 - general: Added a missing feature in the MFilterLIst class which
37 prevented MFEnergySlope from working correctly in trainenergy.C
38
39 - general: Accelerated the random forest training and usage a bit
40
41 - merpp: Adapted to new raw data file format version 6
42
43 - merpp: fixed a problem with reading the starguider reports
44 after 6.3.2006
45
46 - callisto: At some times six pixels had to be exchanged manually in the
47 data. If the pixels to be swaped are both not found, an error was raised
48 and calibration was stopped. Now it is assumed they are intentially not
49 mapped and the Error has been changed to a Warning.
50
51 - star: Added new image cleaning based on the arrival time of the shower.
52 The new cleaning can be accessed using the parameter "Time" instead of
53 the the old one (like "Absolute) in the star.rc-file.
54 Recommended parameters:
55 + MImgCleanStd.CleanLevel1: 8.2
56 + MImgCleanStd.CleanLevel2: 5
57 + MImgCleanStd.CleanRings: 2
58 + MImgCleanStd.KeepSinglePixels: No
59
60 - star: Simplified the calculation of the effective on time. By letting
61 the fit start in the third bin the result should become more stable.
62 The fit quality is now ignored for the theta-plot which is not used
63 in the analysis later. Still better pre-cut which, for example,
64 remove events triggered by car-light (rate changing on a short
65 time-scale) are missing.
66
67 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
68 for optimization (kWeakSource) which is suggested by the Berlin
69 people for weak sources.
70
71 - macros: plotdb.C:
72 + if no dataset and no time-interval is given only sequences with
73 an effective on-time above five minutes are plotted anymore
74 + added a new tab "RelTime" displaying the relative on-time
75 (effective on-time divided by the observation time)
76
77 - macros: optim*.C: by skipping some obsolete calles in the eventloop
78 the optimization became a lot faster
79
80 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
81 To display them just delete the pads displayed on top.
82
83 - ganymed: fixed a bug which could cause strange behaviour in wobble
84 mode if no starguider information was available due to an incorrect
85 initialization of the starguider calibration
86
87 - ganymed: The scale region in the False Source Plot (MHDisp) can now
88 be changed from within the plot. It can also be setup from the
89 resource file using:
90 + MHDisp.fScaleMin: 0.325
91 + MHDisp.fScaleMax: 0.475
92
93 - ganymed, showplot: Fixed a problem with the fit to the off-data
94 (HistOff) which could cause a time lag or an inifinite loop.
95 The bug did not effect the results at all.
96
97 - sponde: Added a new tab showing the effective collection area after
98 trigger (including the software trigger)
99
100 - sponde: MMcSpectrumWeight has a new option which allows to define
101 the scaling factor not by the integral of the events but at
102 a defined energy:
103 e.g. MMcSpectrumWeight.NormEnergy: 200
104
105 - MTFillMatrix, sponde: by skipping some obsolete calles in the
106 eventloops the loop could be accelerated by ~20%
107
108
109
110 *** Version 0.9.5 (2006/03/13)
111
112 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
113 and added the standard Disp-parametrization
114
115 - macros: added a new macro datacenter/macros/plotstat.C allowing
116 to plot statistics about the data processing
117
118 - macros: added a new macro to plot the muon correction coefficients
119 versus period (macros/plot/mucal.C)
120
121 - showplot: path inflation for ganymed files was broken
122
123 - callisto: Fixed an important bug. When the number of saturating pixels
124 were calculated the bad pixel information already available from the
125 calibration was ignored. This yields wrong values in case pixels
126 are broken and saturate all the time or randomly.
127
128 - callisto: Updated Muon calibration constants. Spline data now also uses
129 different values for different periods
130
131 - star: The time-evolution shown in the effective on-time plot now displays
132 the axis range (if there are no holes it should be similar to the
133 effective on-time)
134
135 - star: Added two new image parameters:
136 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
137 the three pixels next to the center of gravity and the size
138 + MNewImagePar.fConcCore: The ratio of the signals of all
139 pixels inside or touching the ellipse and the size
140
141 - ganymed: now stops in requested source isn't found in catalog file
142
143 - ganymed: Many improvements to the phi-plot in wobble mode:
144 + with a template the ideal background is displayed
145 + a possible camera inhomogeneity is taken into account
146 + the anti theta cut is better supported
147 + the phi cut is automatically calculated from the theta cut
148 See the examples in ganymed_wobble.rc for more details.
149
150 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
151 times the bin-width instead of the absolute energy
152
153 - ganymed: New cuts for on/off and wobble mode
154
155 - ganymed: The smearing of the False Source plot has been increased
156 to 0.06
157
158 - ganymed: The starguider calibration can now be changed from the
159 resource file.
160 See the examples in ganymed*.rc for more details.
161
162 - ganymed: added a new option for on-/off-observations
163 MJCut.RandomSourcePosition
164 If switched on the distribution of observation time of the source
165 position in the camera is calculated from the on-data and randomly
166 applied with this distrbution to the off-data.
167
168 - ganymed: by skipping some obsolete calles in the eventloop the
169 first and second loop could be accelerated by ~20%
170
171 - ganymed: The default in ganymed_onoff.rc is now to determin the source
172 position in the off-data randomly according to its distribution in the
173 on-data.
174
175
176
177 *** Version 0.9.4.3 (2006/02/13)
178
179 - general: Fixed a bug in most of the programs which prevented the
180 compile date in the startup message to be displayed
181
182 - general: Simplified program calls. The following abbreviations
183 are now possible:
184 showlog callisto 55599
185 showplot signal 55599
186 star 55599
187 callisto 55999
188 ganymed 2
189 In this cases the corrsponding root-, log-, sequence- or dataset-
190 filename is automatically compiled using the default datacenter
191 paths ("/magic/*")
192
193 - general: Fixed a long outstanding bug which made axis tick marks
194 disappear if MDataFormula was used (eg. abs(x))
195
196 - general: Updated MMath with new functions to calculate the results of
197 a exponential, logarithmic and powerlaw fits analytically.
198
199 - general: Updated some macros with comments:
200 + macros/optim/optimdisp.C
201 + macros/optim/optimenergy.C
202 + macros/optim/optimwobble.C:
203
204 - general: MTFillMatrix (the class to fill one or two MHMatrix from
205 files) now allows adding a pre-cut like in the optimization. E.g. this
206 is useful to perform g/h-separation cuts before training the random
207 forest.
208
209 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
210 correctly assigned in the raw data assignement table. A fix to correct
211 the assignment tabel have been implemented.
212
213 - general: MAstroCatalog now allows rotating of the sky-grid and stars
214 by 90, 180 and 270 deg.
215
216 - general: the macro plotdb.C now allows to highlight sequences belonging
217 to a datset. For more details see the descritions in the macro.
218
219 - StatusDisplay: Fixed the algorithm to calculate the size ratio
220 of the display, it gave wrong results espacially for big sizes.
221 Now the embedded canvas should always have a ratio width/height=3/2.
222 The "Size" options have been updated with values fitting the 3/2
223 size ratio.
224
225 - RanForest:
226 + Updated the random forest classes to support also the
227 regression method implemented by Thomas H.
228 + added new tutorial macro how to train the random forest
229 for energy estimation (macros/optim/rfenergyest.C)
230 + new classes to train the random forest (still in development)
231 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
232 + new tutorial macros for random forest training in macros/train
233 trainenergy.C, traindisp.C, trainseparation.C
234
235 - mars: now allows to setup a cut in the resource file mars.rc to choose
236 the events to be displayed, eg:
237 Cut.Condition: {0} && {1}
238 Cut.0: MHillas.fSize>100
239 Cut.1: MHillas.fSize<900
240
241 - merpp: Made aware of the new .rep format 200510250. This includes
242 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
243 the discriminator thresholds (MCameraTD) and the disciminator
244 delays (MCameraTD). All of them come with the CC report and are therefor
245 written to the CC tree.
246
247 - callisto: fixed a bug in the calculation of the arrival times in
248 the Digital Filter. They were all shifted by the same amount
249 fHiGainFirst. This caused an offset in the order of the position of
250 the left border of the extraction window in the times calculated
251 from high-gain and from low-gain. The bug effected only the absolute
252 arrival times. The bug was there since 30.1.2005.
253
254 - callisto: Changed the ExtractionWindow for the pulse position check
255 such that the camera inhomogeneity becomes as less as possible and
256 comparable to the pulso position check switched off. More details
257 on the study will be given at our result web-page.
258
259 - ganymed: ganymed.rc, ganymed_onoff.rc:
260 changed to new cuts trained with 1ES1218 and Crab-data
261 for maximum sigma*log10(excess)
262
263 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
264 a new option was implemented to estimate Disp (CalcDisp)
265
266 - ganymed: Implemented two new options which allow
267 to overwrite the default path to search for the sequence files
268 --ins=/magic/sequences
269 and where to search for the image data
270 --ind=/magic/data/star
271
272 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
273 dx/dy from the resource file by
274 MSrcPosCorrect.Dx
275 MSrcPosCorrect.Dy
276
277 - ganymed: fixed reading the source catalog. Only as many chars
278 as the requested source name had were compared (If a source
279 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
280 were requested it could happen that the coordinates of
281 "1ES1218" were read) The source coordinates are now printed
282 in addition to its name to the logging output.
283
284 - ganymed: changed the background fit in the case of a ThetaSq function
285 from a polynomial to a exponential, this should give a big improvement
286 for on-only analysis'
287
288 - ganymed/sponde: Calculation of the error of single size-/energy-
289 bins now uses Li/Ma (5) instead of LiMa (17)
290
291 - sponde: Added a plot E^2*dN/dE
292
293 - sponde: The energy estimator plot should now show values like
294 they are commonly used.
295
296 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
297 (a powerlaw with cutoff didn't work before)
298
299
300
301 *** Version 0.9.4.2 (2005/10/01)
302
303 - general: added new tutorial macro macros/tutorials/threshold.C:
304 how to calculate the threshold
305
306 - general: added a new game. Start it from the interpreter with
307 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
308 and MagicReversi)
309
310 - general: neighbor pixels in MGeoms are now sorted clockwise
311
312 - merpp: made aware of new format 20050829-0
313
314 - callisto: New scale factors from muon analysis, stored in new
315 resource file resources/calibration.rc
316
317 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
318 the eventloop if something went wrong. This is necessary for the
319 automatic processing
320
321 - callisto: Implemented a new treatment for the time information
322 developed by S.Ruegamer, this should give much better response than
323 the old very primitive algorithm. This is especially important
324 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
325 treatment was buggy! As neighbor pixels to interpolate the
326 arrival times always the pixels 0 to 5 were taken)
327
328 - callisto: In addition to the new treatment of arrival times the
329 decision of the treatment whether a pixel contains shower
330 information or not is used to improve the signal interpolation
331 further. Previously interpolated pixels showed a non-zero signal
332 do the peak searching signal extractors. Having a signal pixel
333 beside raised the signal above the cleaning level. Thus the
334 pixel survived cleaning to often but with a too low mean signal.
335 By replacing empty pixels with a gaus (mean and rms from the
336 corresponding Area entries in MPedPhotCam) this effect can
337 be supressed.
338
339 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
340 got lost when the events were stored by the calibration... fixed.
341 (This was no problem for normal image cleaning because the pixel
342 content was artificially set to 0 not surviving standard cleaning
343 algorithm)
344
345 - callisto: Fixed a bug which caused the random and peak-search pedestal
346 extracted with an extractor to be exchanged for the first (roughly)
347 500 events (*Extractor and *ExtractorRndm).
348 (They were simply exchanged in callisto.cc) This bug might have been
349 introduced in Mars 0.9.4 when the order of calculation of the two
350 types of pedestal in callisto got exchanged. The bug only effects
351 the first seconds of data of each sequence.
352
353 - star: Taking the arrival time of Muons into account the calculation
354 of the parameters could be made independant of the noise
355 (pedestal rms). The dependance was due to the bias of the peak search
356 extractor. Now only a ZA dependamcy is left which is not yet fully
357 understood.
358
359 - ganymed: The sequences were still not sorted correctly in any case,
360 because they were sorted by the full qualified path name. Now they
361 are sorted by their sequence number.
362
363 - ganymed: new values for the spark-event-cut
364
365 - sponde: required missing MEnergyEst from ganymed.root... fixed.
366
367
368
369 *** Version 0.9.4.1 (2005/08/18)
370
371 - callisto: fixed some problems with the calibration in case of
372 inteleaved events. Therefor the final and some intermediate
373 fits are skipped which would take place on partly filled #
374 histograms and gave wrong results or failed completely.
375
376 - callisto: If the intermediate finalization of the histograms
377 calculating the mean charge of the calibration signal fails
378 it is counted now and printed in PostProcess of MCalibCalcFromPast.
379
380 - ganymed: Fixed some bugs which caused problems in On-only mode.
381 Still the false source plot doesn't give reasonable results.
382
383
384
385 *** Version 0.9.4 (2005/08/05)
386
387 - general: Fixed the ZA binning. It did not correctly fit the
388 MC binning
389
390 - general: Added a class to correct for the missfocussing in
391 April (MSrcPosCorrect)
392
393 - general: Random Forest energy estimator should now work properly
394
395 - general: MHCamera now displays the profiles in deg instead of mm
396
397 - general: MH::SetPalette offers a lot of new palettes
398
399 - general: MHillas - the case of CorrXY==0 is now handled properly
400
401 - general: implemented the possibility to change the line and
402 marker style of a sky-grid drawn by MAstroCatalog
403
404 - general: Runs in sequences and datasets are now automatically
405 ordered (it is assumed that the order of their filenames correctly
406 represents the order of observations) to ensure correct reading
407 of the subsystem data
408
409 - general: Runs cannot be added to a sequence twice anymore. Also
410 Sequences cannot be added twice anymore to a dataset.
411
412 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
413 It gave wrong results by 1./2pi
414
415 - showplot: got a new option to start a root interpreter, too
416
417 - mars: now displays a rough estimate of Disp and the third moment
418
419 - mars: now displays the event time MTime if available
420
421 - mars: show muon parameters graphically
422
423 - mars: now the file to open can be given as commandline
424 argument
425
426 - merpp: Added support for new arehucas version >= 200507190
427 implementing values for three temperature sensors in the
428 counting house (MCameraAUX) and the name of the HV settings file
429 (MCameraHV).
430
431 - merrp: Also fixed some problems with wrong versions numbers stated
432 by arehucas and implemented some fixed for old versions (<200407070)
433
434 - callisto: MCalibrationHiLoCam can now be printed from its context
435 menu, eg in the TBrowser
436
437 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
438 - 1.39 (MExtractTimeAndChargeSpline)
439 - 1.40 (MExtractTimeAndChargeDigitalFilter)
440 This is important mainly for timing studies.
441
442 - callisto: Changed limits in MHCalibrationChargeCalc from
443 - -100.125 to -98 (fgChargeHiGainFirst)
444 - 1899.875 to 1902. (fgChargeHiGainLast)
445 - -100.25 to -99 (fgChargeLoGainFirst)
446 - 899.75 to 901. (fgChargeLoGainLast)
447 Introduced new limits:
448 - fgNumLoGainBlackoutLimit: 0.05
449 - fgLoGainBlackoutLimit: 3.5
450 - fgLoGainPickupLimit: 3.5
451
452 - callisto: The handling of automatic weights for the digital filter
453 has been improved. There are now new calibration weights special
454 for Monte Carlo calibrations.
455
456 - callisto: Updated Muon scale with latest results (1% difference
457 for most data, 5% for Mar/Apr'05)
458
459 - callisto: use a new criterium to exclude bad pixels: If the high-gain
460 was saturated and the blackout-events in the low-gain exceed the
461 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
462 This excludes those pixels which have a saturating high-gain
463 channel, but the low-gain switch does not switch often enough
464 to make the distribution reliable.
465
466 - callisto: fix a bug counting the number of saturated events. Up to now,
467 the number of saturated slices was counted (which is one for a not too
468 high number), but for some (pathological) pixels, many more slices
469 saturated and produced wrong limits.
470
471 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
472 + MCalibrationRelTimeCam.CheckFitResults: Yes
473 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
474 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
475 + MCalibrationRelTimeCam.CheckOscillations: Yes
476
477 - callisto: introduce max. number of events for intercalibration,
478 the rest gets skipped. Default: 4096
479 The calibration causes too many un-reliable pixels if more
480 than about 5000 events are treated (@500 Hz) because of the
481 mode hopping of the VCSels. However, in the past, some
482 calibration runs have been taken (erroneously) with more
483 than 5000 events, especially the intensity scans where
484 a good precision is needed.
485
486 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
487 photo-electrons for the spline extractor by 1-2% (correctly).
488
489 - callisto: The intercalibration is now done using a full f-factor
490 method instead of a simple update. This makes things slower but
491 more reliable in terms of gain-fluctuations and sudden VCSEL gain
492 changes.
493
494 - callisto: MPedestalY3 now uses the same extraction range as the data
495 as calculated by MPedestalY2
496
497 - callisto: A check of the fraction of allowed unsuitable (10%) and
498 unreliable (30%) pixels has been addded when the conversion is
499 calculated from interleaved events
500
501 - star: fixed a bug which caused MEffectiveOnTime containers not to
502 be written. In the worst case they were skipped almost all, in the
503 best case they were all ok. It depends on how often the new value
504 was assigned just with an event which was skipped later by another
505 task
506
507 - star: new histograms MHPointing and MHRate
508
509 - star: New tab (Currents) displaying the time evolution of the mean
510 DC currents
511
512 - star: New tab (MeanRms) displaying the time volution of the mean
513 Pedestal Rms
514
515 - star: Output now contains MReportStarguider
516
517 - star: Improved muon analysis. Due to the absense of a constant
518 for the gaus fit for arc width and the fact that the arcwidth
519 plot was a histogram instead of a profile the resulting psf
520 became pedestal rms dependant
521
522 - ganymed: added new plot (MHPhi) for wobble mode as described in
523 http://www.astro.uni-wuerzburg.de/results/ringmethod/
524
525 - ganymed: corrects now (correctly?) for the misspointing in
526 May/April 05
527
528 - ganymed: Two new default templates for ganymed.rc are avilable:
529 ganymed_onoff.rc and ganymed_wobble.rc
530
531 - ganymed: The first version of MFMagicCuts has been released
532
533 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
534
535 - ganymed, sponde: There are two new options to determin the number
536 of bins for the signal region (NumBinsSignal) and the number of
537 total bins (NumBinsTotal) in the MHThetaSq histogram
538
539 - ganymed: optimized palettes for MHDisp
540
541 - ganymed: Fixed an important bug when using ThetaSq as fit function:
542 The result for the sigma of the gauss(sqrt(x)) fit was a factor
543 sqrt(2) to large
544
545 - ganymed: The false source plot (MHDisp) is now based on Disp
546 and a background model determined in the first loop is
547 subtracted
548
549 - ganymed: MFMagicCuts are now available in the cvs. The correct
550 solution for the disp ambiguity problem is now calculated using
551 the third moment. The third moment cut therefor is skipped.
552
553 - ganymed: Output now contains "Disp [MParameterD]" which sign is
554 already determined by the third moment along the major axis and
555 so its actual sign is aligned along the major axis of the shower.
556
557 - ganymed: If starguider data is available it is taken into account
558 when calculating the source position. This is especially important
559 for wobble data at high zenith angles and culmination data.
560
561 - ganymed: If available the starguider data is taken into account as
562 good as it is possible without a starguider calibration. To switch
563 it off add
564 MPointingDevCalc.MaxAbsDev: -1
565 to your ganymed.rc
566
567 - sponde: the zenith angle distribution is now weighted instead of
568 choosen by default. This gurantees higher statistics in the highest
569 and lowest energy bins. To switch this behaviour off use...
570
571 - sponde: now automatically displays the energy threshold
572
573
574
575 *** Version 0.9.3 (2005/06/03)
576
577 - general: MMcEvt now derived from MMcEvtBasic which should
578 have no influence on compatibility with older camera files
579
580 - general: Implemented a new option to MReadReports which allows
581 to force reading of the first event of some trees (eg. Drive-tree)
582 before any other tree.
583
584 - general: Made a fix to MPointingPosCalc which assumes that the
585 run-type is real-data if Process is called before ReInit, such
586 that also the very first Drive-events in a run are treated
587 correctly.
588
589 - shoplot now displays the filename in the title bar of the window
590
591 - merpp: new options: --auto-time-start --auto-time-stop which
592 allow to cut updating with slow-control at the start- or
593 (previousle --auto-time only allowed: and) stop-time of
594 the run stored in the runheader.
595
596 - callisto: changed default of fgFallTimeHiGain in
597 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
598 already set as default in callisto_Dec04Jan05.rc
599
600 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
601 now changes the filename for new weights automatically for
602 cosmics, MC and for different calibration colors.
603
604 - callisto: a problem with the order of some code cause the
605 name of the weights file in MPedestalY2 to be ignored.
606 Wrongly the calibration_UV weights were used instead
607 of the cosmics weights set in callisto.rc.
608
609 - callisto: should allow ct1 pulser data when the color is
610 explicitly set also for pretty new runs
611
612 - callisto: a new option (MCalibrateData.ScaleFactor) allows
613 to introduce an additional scale factor (should be around 1)
614 to adapt for slight deviations in different extractors from
615 the MC calibration. For MC calibrations the scale factor
616 is fixed to 1
617
618 - callisto: MFCosmics should handle very high signals a bit
619 more accurate now
620
621 - callisto: when calculating the mean pedestal rms for different
622 pixel sizes or sectors also kUnsuitableEvt is now taken into
623 account - not only kUnsuitableRun
624
625 - callisto: '-raw' option is now the default
626
627 - callisto: A dead pixel check has been implemented in MJPedestalC2.
628 This has the advantage that mean values in the calibration (eg
629 arrival times) are calculated more accuratly.
630
631 - callisto: In the resource file callisto_Dec04Jan05.rc
632 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
633
634 - callisto: new Hi-/Lo-Gain intercalibration constants
635 hilocalib_sp1.root and hilocalib_sp1_mc.root
636
637 - callisto: changed default for MJPedestalY2.MaxEvents
638 from 2000 to 5000 like in callisto_Dec04Jan05.txt
639
640 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
641 has changed from 9.0 to 6.0. This is necessary to exclude two very
642 ringing pixels in September which - when kept - destroy the image
643 cleaning around them (Markus G.)
644
645 - callisto: (!) The Muon analysis of all data taken so far has
646 suggested that different extractors give slightly different
647 absolute results after calibration, due to there different
648 handling of the calibration- and cosmics pulse shape. Although
649 the over all calibration seems to be a bit to pesimistic (or
650 the MC seems to be a little bit - 3-5% - too much attenuated).
651 There for correction factors have been introduced which correct
652 the calibration constants by
653 0.956937799 for Digital Filter (callisto.rc)
654 and
655 0.904159132 for Spline (callisto_Dec04Jan05.rc)
656 calibration. The main advantage is, that both data types can
657 be easily analysed together and compared to the same MC sample.
658 The factors are choosen such, that the reference is now a
659 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
660
661 - star: fixed a bug which caused the first bin of the histograms
662 vs time to disapear in PostProcess. This gave wrong results
663 on the screen. The output and all following programs not
664 directly accessing the histograms haven't been affected
665
666 - star, ganymed: Made sure that always the first Drive-tree event
667 is read and Processed before the first data event was read.
668
669 - ganymed: implemented the possibility to replace the standard
670 false source plot with a different one. For example: If
671 you want to use a Disp based FS plot use the resource:
672 NameHistFS: MHDisp
673 For details about the requirements of these plots look
674 at the corresponding classes
675
676 - MJOptimize: For On/Off and Wobble optimization MJOptimize
677 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
678 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
679 case MAlphaFitter is setup correctly. For On-Only optimization
680 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
681 RunOn() instead of Run(). For energy estimation MJOptimize
682 has been replaced by MJOptimizeEnergy
683
684 - sponde: The input MC spectrum can now be weighted to fake a
685 different spectrum. This is done via MMcSpectrumWeight. For
686 more details see the class description and sponde.rc
687
688 - sponde: The paremeter comparsion plots are not scaled by
689 their entries anymore. Instead the MC plot is scaled by using
690 the result spectrum of the analysis. If the input MC spectrum
691 and the result spectrum has different slopes the absolut
692 normalization is normally wrong.
693
694
695
696 *** Version 0.9.2 (2005/05/20)
697
698 - general: Changed the default paths for calibrated data and image
699 files. (The implemented access to these files doesn't yet exist)
700
701 - general: support for MRunIter has been removed from the job classes
702 (use the setter functions of MSeqeunce instead)
703
704 - general: ProcessFile has been renamed to Process in all job classes,
705 because ProcessFile is missleading
706
707 - general: The storage of the palette in MHCamera is now possible
708
709 - general: new bits describing unsuitable and unreliable pixels have
710 been introduced in MBadPixelsPix: kPreviouslyExcluded,
711 kDeadPedestalRms, kFluctuatingArrivalTimes
712
713 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
714 versions newer than V200404070
715
716 - general: support for cc file versions newer than V200504130. Added
717 support for active loads (MCameraActiveLoad) and central pixel
718 (MCameraCentralPixel)
719
720 - general: added new histograms for image parameters versus size
721 (MHVsSize)
722
723 - general: The eventloop now automatically calls PrintStatistics
724
725 - Status Display: Improved support for printing:
726 + A default can now be set in .rootrc (for more details see
727 MStatusDisplay::PrintPS)
728 + A print dialog is opened so that printer and command line
729 can be canged
730
731 - showlog: improved such that it handles different verbosity levels
732 more accurate now. This mean you can suppress output when
733 using showlog.
734
735 - showplot: improved
736 + The new graphics formats have been implemented
737 (pdf, svg, png, jpg and xpm)
738 + Implemented an interface for printing. Because you can change
739 the printing command from the command line you can use all
740 the nice postscript tool. To print a booklet for example call:
741 showplot -b --print --print-cmd="cat %f" filename.root | lpr
742 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
743 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
744
745 - callisto: fixed a bug in the recognition of the calibration bit
746 pattern. Concerns only intensity calibration. (The strength of the
747 intensity has been updated in some cases)
748
749 - callisto: add a filter against PIN Diode events when running over
750 calibration runs since some of the recent calibration runs have
751 been taken with Pin Diode.
752
753 - callisto: added support for the runs 39942, 39944, 44834, 39941,
754 39943, 44833 in the calibration (MCalibColorSet)
755
756 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
757 been set to 1e-18 in callisto_Dec04_Jan05.rc
758
759 - callisto: in callisto_Dec04Jan05.rc: set value for
760 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
761 statistics for the calculation of the mean pulse time
762 of the cosmisc
763
764 - callisto: the charge limit in the calibration has been raised
765 from 2.5 to 4.5
766
767 - callisto: new setup read from callisto.rc
768 + MCalibCalcFromPast.fNumEventsDump
769 + MHCalibrationChargeCam.NumHiGainSaturationLimit
770 + MHCalibrationChargeCam.NumLoGainSaturationLimit
771
772 - callisto: MExtractTimeAndChargeSpline extractor:
773 + The integration ranges were shifted by 0.2 FADC slices to the right.
774 + unreliable handling of floating point values caused different
775 results on different platform or with different compiler options:
776 The new algorithm is numerically exact and more accurate because
777 it doesn't calculate the integration position by multiple times
778 adding the step-size (which results in numerical uncertanties
779 exspecially if multiplied with large numbers)
780 + A lot of fixes have been introduced which effects integrating the
781 spline at the edges of the valid range. In this case any memory
782 was randomly accessed. This behaviour can be tested replacing
783 all MArrayF by TArrayF which perform a range check (but of course
784 they are a lot slower)
785 ! No result obtained with the Spline before can be trusted! Due to
786 random memory access it might by completely random!
787
788 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
789 + extraction range in the high gain to 4.
790 + weights file to cosmics_weights46.dat
791
792 - callisto:
793 + introduce the check for fluctuating arrival times.
794 + set charge limit to from 2.5 to 4.5
795 + introduce asymmetric exclusion due to "deviating number of phes":
796 Default: -9.0 +4.5
797 + make deviating number of phes unsuitable (see David's findings).
798
799 - callisto: fixed the display of unsuitable pixels. The old change
800 to a real profile in MHCamera broke it.
801
802 - callisto: The cosmics filter is used in MJCalibration now
803 independant of the pulser color (formaly it was used only for
804 CT1-pulser data). The threshold of number of max empty pixels
805 has been raised from 2% to 5% in MJCalibration. The maximum
806 fraction of rejected event is 50% otherwise the calibration has
807 failed. The filter now ignores unsuitable pixels.
808 Setup the filter from callisto.rc using "ContCosmics"
809 (see MFCosmics::ReadEnv)
810
811 - callisto: changed default for fgOffsetFromLogain back
812 from -2.8 to -1.8 in digital filter.
813
814 - callisto: for the common extractors
815 + MExtractFixedWindow
816 * MExtractTimeAndChargeSlidingWindow
817 * MExtractTimeAndChargeSpline
818 * MExtractTimeAndChargeDigitalFilter
819 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
820 and fResolutionPerPheLoGain
821
822 - callisto: Updated the hi-/lo-gain intercalibration constants
823 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
824 hilocalib_df6.root
825
826 - callisto: The default lo-gain extraction window for the
827 MExtractTimeAndChargeSlidingWindow extractor has been increased
828 from 6 to 8 to take the stretch of the pusle into account
829
830 - callisto (!!!): fixed an important bug in the setting of the
831 incoming pedestal pointer to the signal extractor extracting
832 pedestals. This bug caused the pedestals not to be subtracted
833 correctly in the calibration afterwards. The effect was about 10%
834 too high conversion factors for the digital filter and the spline
835 and more than 40% for the sliding window.
836 The bug existed since end of February! (Markus G.)
837
838 - star: added muon support to star. A new tab "MHMuonPar" is
839 displayed. The lower right plot is an estimate of the point spread
840 function. A reference value is displayed. To get the real PSF
841 you must compare with MC. The setup for the muon analysis
842 is done in star.rc. More informations can be found in
843 MHSingleMuon and MHCalibParCalc
844
845 - star: The weather data is now displayed in star
846
847 - star: MEventRateCalc handles the calculation of the event rate more
848 accurate now in case of the start of a new run inside a sequence
849
850 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
851 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
852 changed only minimally
853
854 - ganymed: (MJCut and MJOptimize) now displayes the number of
855 excess events versus size. The energy estimation is done in
856 MJSpectrum (sponde)
857
858 - ganymed: got support for using other variables than Alpha, eg. Theta.
859 Therefor you need a class deriving from MHAlpha which supports
860 this variable (one is already existing: MHTheta, which is now the
861 default in ganymed). It is setup through ganymed.rc
862
863 - added a full featured spectrum program (sponde) which reads
864 ganymed output and monte carlos and compiles a spectrum
865
866
867
868 *** Version 0.9.1 (2005/04/14)
869
870 - Fix bug on the arrival time reconstruction when using Digital
871 Filter (in some marginal cases (10%) times were reconstructed shifted
872 by 0.2 slices)
873
874 - all executables now return 2 where in previous versions -1 has
875 been returned (gave problems with shell-scripts)
876
877 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
878 also done with a intercalibration input file
879
880 - a bug in the time fine adjustment of the digital filter has been fixed
881
882 - a lot of small fixes to calling TPad::Divide with a margin==0
883
884 - MStatusDisplay now shows the memory usage
885
886 - added a memory leak statistic after the eventloop
887
888 - MHadronness replaced by MParameterD
889
890 - MEnergyEst replaced by MParameterD
891
892 - wobble mode can now be switched on from the data-set
893
894 - switched on bad pixel detection for a pedestal level
895 which is more than 5 times the variance
896
897 - Fixed default paths to be correct for the new data center
898
899 - Fixed handling of drive data. The pointing position in now
900 copied to MPointingPos inside star for real and MC events
901
902 - made sure, that the sequences in a dataset are sorted by
903 their number to ensure the correct synchronization
904
905 - added all resource files necessary to handle spline extraction
906 of signal for the late 2004 and the early 2005 data
907
908 - update the reference lines for the december data
909
910 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
911 This is important for the Dec. and Jan. data where the calibration
912 pulse position changes much.
913
914 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
915 filter. This corrects only an defective extraction of the MC at
916 low-gain signals lower than 90 phes.
917
918 - fixed some slowdown in calibrating data with interleaved events from
919 Jan and Dec. As a workaround made the pretty palette the default.
920 The inverse Deep Blue Sea has a bug which slows down long calibration
921 runs a lot.
922
923 - implemented new values from new starguider report as defined
924 in TDAS00-07 V7.1 (eg SkyBrighness)
925
926 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
927 in starguider report (If you merpp the same reports with this version
928 you'll get the correct units (arcmin) but a different result
929 than with old versions (wrong units))
930
931 - Now the status display can also write PNG, JPEG and XPM (other file
932 formats are still unsupported by root)
933
934 - added a lot of scripts and macros in directory datacenter used
935 for automatic processing
936
937
938
939 *** Version 0.9 (2005/03/23)
940
941 - Calibration is now done autmatically into photo-electrons like
942 decided by the Collaboration Board
943
944 - Reference lines in the display can be read from resource file
945
946 - Interlaced calibration events can be handled by callisto
947
948 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
949 and applied in callisto.
950
951 - class MJCalibTest can be called by callisto
952
953 - callisto can now run with three data types: rawdata, rootdata, MC
954
955 - added two classes mreport/MReportStarguider.cc and
956 mreport/MReportStarguider.h for implementing starguider-data
957
958 - the output of merpp-update now contains starguider information:
959 MReportStarguider and MTimeStarguider
960
961 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
962 values were lower than they should. This was more visible for high
963 energy (Size) events.
964
965 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
966
967 - added a new loop to callisto to support the correct extraction of
968 the pedestal and pedestal rms through the signal extractor
969
970 - added class to perform fourier tranformation of a hexagonal structure
971 (MHexagonalFT)
972
973 - added class to perform fourier tranformation of a hexagonal structure
974 in a tasklist (MHexagonalFTCalc) example: hft.C
975
976 - added class to enhance the MCerPhotEvt from the Magic camera geometry
977 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
978 small pixels, example: extendcam.C
979
980 - added possibility to write data to memory (TTree) using MWriteRootFile
981
982 - added possibility to read a TTree stored only in memory by MReadTree
983
984 - new classes to deal with the interleaved calibration events:
985 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
986
987 - implemented filters to callisto to skip calibration events
988
989 - changed callisto to calculate three kinds of pedestals and pedestal rms:
990 + fundamental pedestal (MPedPhotFundamental): extracted directly from
991 the slices by statistics
992 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
993 signal extractor without randomization
994 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
995 with the signal extractor with randomization (extraction window is
996 randomly fixed)
997 The three kind of pedestal is not yet implemented (for speed reasons) as
998 long as nobody really needs it:
999 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1000 extracted with the signal extractor with randomization
1001
1002 - callisto now finds the pulse position in the data automatically
1003
1004 - implemented data reduction in calibrated data by reducing the precision
1005 of the stored floating point values (pedestal, rms and signal) to
1006 roughly 0.5%
1007
1008 - fixed showplot to make file format conversion (eg. converting a
1009 status display stored in a root file into a postscript file) in
1010 batch mode possible:
1011 showplot -b --save-as-ps[=outfile.ps] infile.root
1012
1013 - Allow class names as part of filter rules, eg
1014 (MFSupercuts) && (MHillas.fSize>100)
1015
1016 - fixed a lot of stuff to allow all programs to process MonteCarlo
1017 camera files.
1018
1019 - enhanced possibility to debug reading of resource file
1020
1021 - MDataChain should handle priorities of operator more
1022 accurate now
1023
1024 - completely revised the container in which the signal is stored
1025 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1026 * the new implementation is faster and
1027 * needs less storage space
1028
1029 - FIRST version which can process Monte Carlos through the
1030 whole chain of programs (callisto, star, etc)
1031
1032 - implemented new image parameters for the border length of
1033 the shower image (MNewImagePar2)
1034
1035 - implemented wobble-mode in ganymed
1036
1037 - new class (MJOptimize) taking care of all optimization processes
1038
1039
1040
1041 *** Version 0.8.6 (2004/10/05)
1042
1043 - New combined signal and time extractor
1044 MExtractTimeAndChargeDigitalFilter
1045
1046 - The Report for the trigger section in the CC run summary has been
1047 updated, and now the IPRs (Individual Pixel Rates) are available.
1048
1049 - new macros for database interaction: filldotrun.C, filldotrbk.C
1050
1051 - added new program which can convert colored output which was redirected
1052 into a file back into colored text (for example to display it with
1053 more): showlog
1054
1055 - added new program to display an MStatusArray of plots (stored with
1056 MStatusDisplay) from a file: showplot
1057
1058 - Added support for Sequences (MSequence). Sequences are blocks of run
1059 files containing the same calibration and belonging to the same
1060 source
1061
1062 - Added a new task (MTaskEnv) which can be used in setup files to switch
1063 between different tasks (for example to choose a signal extractor)
1064
1065 - Implemented automatic file splitting in MWriteRootFile
1066
1067 - After image cleaning an island index is assigned to all used pixels.
1068 The index corresponds to the order of the islands in size.
1069
1070 - added a cleaning which takes signal height _and_ arrival time into
1071 account: probability cleaning (for more details see MImgCleanStd)
1072
1073 - added a cleaning which takes takes the absolute number of photons
1074 times the area ratio as cleaning level
1075 (for more details see MImgCleanStd)
1076
1077 - Changed calculation of image parameters such, that it can be done
1078 for all used pixels or the pixels with a defined island index only
1079
1080 - implemented new image parameters displaying the number of islands,
1081 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1082
1083 - event display in executable changed to support also calibrated files
1084 (done with MJCalibrateSignal)
1085
1086 - added program doing the calibration and the signal extraction
1087 and signal calibration: callisto Most part of the setup is done
1088 by a resource file: callisto.rc
1089
1090 - implemented support for pixels with negative IDs (Raw file format
1091 version 4)
1092
1093 - implemented an new option in merpp (--auto-time) to get the time
1094 range for cc and/or caco data from the run header of the raw data
1095
1096 - New star-program (star and MJStar). Taking calibrated data from
1097 callisto/MJCalibrateSignal as input. The setup is done through
1098 a resource file: star.rc
1099
1100 - Added possibility to setup the eventloop in the mars-executable
1101 Camera Display by a resource file: mars.rc
1102
1103 - The the mars-executable Camera Display can now also read
1104 calibrated data files written by callisto/MJCalibrateSignal
1105
1106 - Added a new class which can calculate the source position in
1107 the camera from a pointing model known to be correct and
1108 the pointing model used for observations (MSrcPosFromModel)
1109
1110 - added a new version of the class calculating the effective on-time
1111 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1112 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1113 MHTimeDiffTheta.
1114
1115 - added the possibility to count how often a signal is above (or
1116 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1117 can replace MHTriggerLvl0)
1118
1119 - added ore convinient ways to set the axis-titles of your histograms
1120 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1121 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1122
1123
1124
1125 *** Version 0.8.5 (2004/08/06)
1126
1127 - new Signal Extractors: MExtractFixedWindowSpline
1128 and MExtractAmplitudeSpline
1129
1130 - implementes interleave in merpp to be able to merpp parts of a file
1131
1132 - implemented force-functionality to merpp
1133
1134 - star display to display star catalogs (MAstroCatalog)
1135
1136 - star display to 'mirror' stars to the camera (MAstroCamera)
1137
1138 - implemented a new cleaning option which allows cleaning scaled with
1139 the real ratio of the rms depending on the pixel size, not only the
1140 square root of the pixelsize (MImgCleanStd, MCameraData)
1141
1142 - removed obsolete MBlind* classes
1143
1144 - Signal extractor taking the AB flag into account implemented (this makes
1145 an odd number of slices for signal extraction possible
1146 (MExtractSignalABcorr)
1147
1148 - implemented a class extracting the pedestal from the raw-data (events)
1149 itself using empty lo-gain (MpedCalcFromLoGain)
1150
1151 - Added mean values to MPedPhotCam
1152
1153 - Added Makefile for Darwin (this OS is NOT officially supported!)
1154
1155
1156
1157 *** Version 0.8.4 (2004/04/19)
1158
1159 - new fast arrival time extractor using cubic splines:
1160 MExtractTimeFastSpline
1161
1162 - implementes multi-argument support in MDataChain
1163 ("pow(a, b)")
1164
1165 - implemented double reference support in MDataChain
1166 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1167
1168 - added support in MF for expressiond like
1169 "MHillas.fWidth<2*<MHillas.fLength"
1170
1171 - MDataChain is now able to support variables like [0], [1], ...
1172 which can be used in fit functions as parameters. The interface
1173 is implemented through the new virtual function
1174 MParContainer::SetVariables
1175
1176 - added new class MArrivalTimeCam/MArrivalTimePix:
1177 Storage containers to hold the ArrivalTime of the camera/pixel
1178
1179 - added new classes for the calibration of relative arrival times:
1180 MCalibrationRelTimePix and MCalibrationRelTimeCam
1181
1182 - added new classes to extract the signal of the blind pixel and the
1183 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1184
1185 - added new classes for the bad-pixels treatment (MBadPixels*)
1186 which are more powerfull than the old ones (MBlindPixel*)
1187 and will replace them.
1188
1189 - added filter against cosmics: MFCosmics
1190
1191 - added new class MArrivalTimeCalc2:
1192 Calculates the arrival time as the signal weighted mean of the time
1193 slices in the maximum window
1194
1195 - added a new macro call pointspreadfucntion.C that fits with a 2D
1196 gaussian the DC spot for an star. It gives you the RMS of
1197 the PSF and the center of the star, very useful for misspointing
1198 studies.
1199
1200 - added support for multi-telescope camera files. Added classes
1201 MStereoCalc and MStereoPar, classes to calculate and store shower
1202 parameters calculated from the data of two telescopes, for the MC
1203 studies regarding the MAGIC clone.
1204
1205 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1206 MC data calibrated in photons instead of ADC counts.
1207
1208 - added three macros to show the calibration and analysis chain of
1209 MC data. The macro starmc.C does both calibration and analysis, producing
1210 an output containing Hillas parameters for each event. The macro
1211 mccalibrate.C does just the calibration and writes out a file containing
1212 pixel information in photons instead of FADC data. The macro starmc2.C
1213 reads in such a file and produces an output with Hillas parameters.
1214
1215 - added MPedPhotCalc to compute pedestals in units of photons, see
1216 macro pedphotcalc.C
1217
1218 - added all class to perform the calibration, see macro calibration.C
1219
1220 - added class MFFT to perform Fast Fourier Transforms
1221
1222 - added class MSimulatedAnnealing to perform simulated annealing
1223 minimizations
1224
1225 - added new macro bootcampstandardanalysis.C which holds the skeleton
1226 of the analysis chain discussed in the december bootcamp.
1227
1228 - added support for DAQ raw data file format V2
1229
1230 - implemented an arbitrary time stamp for the events from raw-data
1231 files with file version<3. It is calculated from the run number,
1232 the date of start and the FADC clock tick from the first module
1233
1234 - implemented the correct decoding of the event time-stamp
1235 coming from the DAQ for raw-data files with file-version>2
1236
1237 - added a new classes storing the pedestals in units of photons:
1238 MPedPhotPix, MPedPhotCam
1239
1240 - added support for DC current files from the camera control
1241
1242 - added support for start- and stop-time when merpping report files
1243
1244 - added MReportCC storing the weather data from the CC-REPORT
1245
1246 - added class to fill trainings and test matrices (MTFillMatrix)
1247
1248 - added a filter performing a software trigger (MFSoftwareTrigger)
1249
1250 - Added classes to perform parts of the standard analysis (Jobs):
1251 + MJPedestals
1252 + MJCalibration
1253 + MJExtractSignal
1254 Note: All of them are preliminary!
1255
1256 - Added Iterator to iterate over files giving only the run-number
1257
1258 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1259 the evolution of a sector vs time
1260
1261
1262
1263 *** Version 0.8.3 (2003/12/05)
1264
1265 - adapted Random Forest classes to allow the use with MC
1266 multi-telescope files which can be produced with the coming
1267 camera version 0.7.
1268
1269 - added classes to read and interprete central control report files
1270 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1271
1272 - enhanced merpp (the executable) to support .raw and .rep files.
1273
1274 - added classes for light calibration (MCalibration* and
1275 MHCalibration*) by Markus Gaug. Further work has to be and will
1276 be done soon.
1277
1278 - Added a preliminary 'synchronizer' (MReadReports) which will
1279 replace MReadMarsFile as soon as it is finished.
1280
1281 - Added a tutorial macro demonstrating how report files are merpped
1282 and how they can be read from the root file in the correct order
1283 of time (readrep.C)
1284
1285 - Added a generalized histogram (similar to MH3) called MVsTime
1286 which allows to plot variables (or rules - MDataChain - of
1287 variables) vs time. For an example have a look at tempvstime.C.
1288
1289 - Changed the name of the event trees:
1290 + Events --> Events
1291 + PedEvents --> Pedestals
1292 + CalEvents --> Calibration
1293
1294 - changed name of MTime in the event trees from MRawEvtTime to MTime
1295
1296 - added displaying the sector indices to the mars event display
1297
1298 - Magic Online Analysis (MOnA) implemented in a first version
1299 (see mona.cc, MOnlineDump and MOnlineDisplay)
1300
1301 - added classes to calculate event rate
1302 (preliminary: MEventRateCalc, MEventRate)
1303
1304 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1305
1306 - added classes dealing with the telescope pointing position (MPointing*)
1307
1308 - implemented the 'final' Mars time stamp based on some experiences with
1309 the new 'Synchonizer'
1310
1311
1312
1313 *** Version 0.8.2 (2003/11/10)
1314
1315 - accelerated standard analysis by a factor of 6-8 ...
1316 + doing precalculations in MGeomCam for the pixel area ratio
1317 + creating a look up table for the single pixels in MCerPhotEvt
1318
1319 - added task to calculates weights in case you want to 'change'
1320 the energy spectrum of a monte carlo file
1321 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1322
1323 - added a new executable star which implements the
1324 star.C macro as precompiled executable. Currently a flexible
1325 setup is not possible, but a 'input card' setup will follow.
1326
1327 - Starting to implement Multi-Telescope-Support based on the
1328 upcomming camera version 0.7. The base for a general support
1329 is implemented and the star-functionality is proven to work.
1330
1331 - Replaced Event-Display in and Camera-Display in the Mars GUI
1332 executable by a more convinient display base on MStatusDisplay.
1333
1334 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1335
1336
1337
1338 *** Version 0.8.1 (2003/10/20)
1339
1340 - added signal subtraction for pure on data by means of fitting
1341 the background in the off region or by performing a combined
1342 signal/background fit. Provides necessary histograms for
1343 obtaining energy spectra and a light curve.
1344
1345 - added classes to perform and study the selection of the
1346 2nd Level Trigger on MC data (example in triglvl2.C macro)
1347
1348 - added pedestal calculation
1349
1350 - implemented "democratic cleaning" (tail cut value proportional
1351 to pixel area) according to Wolfgang's suggestion.
1352
1353 - added Sigmabar treatment (calculation and basic histogramming)
1354
1355 - added basic routines to apply padding
1356
1357 - added first implementation of MARS-based source visibility plotter
1358 (needs to be linked against slalib, preliminary version)
1359
1360 - enhanced functionality of data chains: random numbers, conversion
1361 functions and access to MHMatrix objects
1362
1363 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1364 numbers under certain circumstances (runs with 0 events included)
1365
1366 - fixed a bug in the general filter MF (didn't work on some systems
1367 at all)
1368
1369 - fixed a bug in chaining files, which caused the analysis to crash or
1370 ignore files
1371
1372 - implemented more geometry classes describing the parameters used
1373 to simulate the PMT camera
1374
1375 - added new Monte Carlo classes containing the setup of the different
1376 programs in the MC chain.
1377
1378 - added a (preliminary) general task to evaluate chi-square of a given
1379 parameter in an eventloop.
1380
1381 - first implementation of a container describing the observatory
1382 location (Long, Lat, etc)
1383
1384 - added Random Forest - method for g/h-separation
1385
1386 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1387 (this means, that it is compiling, but not yet fully tested)
1388
1389 - added a new status display which can show the present status
1390 of histograms while an eventloop is running (MStatusDisplay,
1391 an example can be found at status.C)
1392
1393 - reorganized directories:
1394 classes describing the image --> mimage
1395 classes containing Monte Carlo Histograms --> mhistmc
1396 classes for Random Forest method --> mranforest
1397
1398 - added (event-)weights to fill histograms
1399
1400 - colors in logging output to screen
1401
1402 - changes to the Image Parameter declaration:
1403 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1404 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1405 + MHillasExt now derives from MParContainer instead of MHillas
1406 --> Files written with the old definition are more or less unreadable
1407
1408 - reading of reflector files
1409
1410 - display data from reflector files in the camera
1411
1412 - implemented currents (and display them in the camera)
1413
1414 - logarithmic scale in camera
1415
1416 - added class to iterate through directory contents (MDirIter)
1417
1418
1419
1420 *** Version 0.8 (2002/11/18)
1421
1422 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1423
1424 - corrected 48(!) wrong entries in the Next Neighbor table of the
1425 Magic Camera (all in the inner part of the outer ring, mostly
1426 missing a single NN)
1427
1428 - Fixed a bug in the table describing the Next Neighbours of the
1429 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1430 have any neighbour)
1431
1432 - changed trigrate.C: now it calculates the pure NSB triggers from
1433 a camera file (generated with no showers), so there is no need
1434 to introduce them by hand in the BgR array (for more details
1435 please ask Abelardo)
1436
1437 - added MHHadronness (and MHadronness) as a general facility to evaluate
1438 the quality of a gamma-hadron seperation method
1439
1440 - changed MWriteAsciiFile to accept rules (MDataChain)
1441
1442 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1443 must be replaced by calles to MWriteAsciiFile::AddColumn and
1444 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1445 changed.
1446
1447 - Implemented generalized event-matrices (one row per event)
1448 (MHMatrix)
1449
1450 - implemented the one dimensional composite probabilities
1451 (MHCompProb, MCompProbCalc, comprob.C)
1452
1453 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1454 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1455
1456 - Added a camera display displaying the pixel numbers to the
1457 event display gui.
1458
1459 - Added Monte Carlo Informations to event display gui
1460
1461 - Changed the camera display to display the pixel numbering
1462
1463 - Added three buttons to the camera display to change the palette
1464
1465 - Added the number of used and core pixels after image cleaning
1466 to MHillas
1467
1468 - Changed the algorithm used in MHillas according to TDAS 02-03
1469
1470 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1471
1472 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1473
1474 - Added fCosDeltaAlpha to MHillasSrc
1475
1476 - The numbers of photons used to calculate fConc and fConc1 in
1477 MHillasExt are now scaled with the pixel size, so that one get
1478 a four times smaller value for the bigger pixels in the outer ring.
1479
1480 - added new task to smooth the camera contents (MCameraSmooth)
1481
1482 - added possibility to use interpolated pixel values for blind pixels
1483 instead of removing it completely from the analysis
1484
1485 - Implemented the possibility to save the whole eventloop with
1486 its setup to a file. This information can be read and from
1487 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1488 and MEvtLoop::MakeMacro. If you find something not working, please
1489 report - this stuff is still in a beta phase.
1490
1491 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1492 file having crab starfield, but also for all following files - fixed
1493
1494 - MTaskList::PrintStatistics can now be instructud to print also the
1495 title, too: use PrintStatistics(0, kTRUE)
1496
1497 - Changed the image cleaning so that pixels with to many 'used'
1498 neighbors are left used (to get rid of 'holes' in events)
1499
1500 - Introduced more output to the camera displays
1501
1502 - Added an array of histograms (eg one hist per run), MHArray
1503
1504 - Added a _preliminary_ version of the reader for CT1 PreProc files
1505 (MCT1ReadPreProc)
1506
1507 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1508 (thanks to Raquel)
1509
1510 - added the first energy estimator (MEnergyEstParam, estimate.C,
1511 estfit.C) using a parametrization
1512
1513 - Added some new Monte Carlo paremeter containers used to store
1514 setup information from the MC chain (MMcConfigRunHeader,
1515 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1516
1517
1518
1519 *** Version 0.7 (2002/04/30)
1520
1521 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1522 the pedestal mean value was saved incorrectly. For files from
1523 this versions we substract 0.5 from the pedestal mean.
1524 WARNING: This may effect your results, so don't wonder...
1525
1526 - First implementation of an algorithm using only triggered events
1527 for the collection area calculation
1528
1529 - Ascii Output can now also be used for parameter containers which
1530 doesn't overload MParCointainer::AsciiWrite
1531
1532 - The Ascii Output is now also capable of writing single data members
1533 of one container
1534
1535 - You are now able to change the order of the values written to the
1536 ascii file
1537
1538 - You can now specify a conversion factor for each data member written
1539 to an ascii file. This may be usefull to change the units of the
1540 data member (eg. degrees instead of millimeters in case of the
1541 hillas parameters)
1542
1543 - Replaced old MHillas by a new structure which allows you to extend
1544 the parameters stored in MHillas very easily:
1545 see MHillas and MHillasExt
1546
1547 - Added classes to handle source dependancy of image parameters:
1548 see MHillasSrc
1549
1550 - Added container (MBinning) to have a standard input for the binning
1551 in different histograms (eg. the Energy bins should be the same in
1552 all histograms)
1553
1554 - Changed Hillas histograms from mm to deg
1555
1556 - Added the flexible binning to the hillas histograms
1557
1558 - Added a filter for the alpha parameter (MFAlpha)
1559
1560 - It is now possible to write single data members of a class object to
1561 an output stream instead of the whole container only
1562
1563 - Added a generalized filter for a data member:
1564 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1565
1566 - Added a generalized Filter parser for more difficult filter rules
1567 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1568
1569 - Added new Monte Carlo histograms:
1570 MHMcEnergyImpact and MHMcEfficiency
1571
1572 - Added many new histograms needed for the flux calculation.
1573
1574 - Added a generalized histograms which can fill and show up to three
1575 data members in either a one-, two- or three-dimensional histogram, eg:
1576 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1577
1578 - Added:
1579 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1580 * calculation of <Theta> as a function of time (MHThetabarTime)
1581 they are needed in the flux calculation in
1582 order to select for a given bin in Theta (or time) the appropriate
1583 effective collection area, which is assumed to be given as a function
1584 of Theta and the true energy
1585
1586 - Added calculation of the migration matrix in the energy
1587 (MHMcEnergyMigration):
1588 the migration matrix describes the migration from the true (E_true)
1589 to the estimated energy (E_est); it is needed to determine the
1590 distribution of E_true from the measured distribution of E_est
1591 by unfolding
1592
1593 - changed the color palette in the camera display to DeapSea.
1594
1595
1596
1597 *** Version 0.6 (2002/01/15)
1598
1599 - Introduce the option of disable pixels (MBlindPixels and
1600 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1601 able to deal with Star Field NSB.
1602
1603 - Fixed a bug in the pedestals substraction
1604
1605 - Introduced verbosity levels
1606
1607 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1608
1609 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1610 work correctly (thanks to Abelardo)
1611
1612 - Introduced correct treatment of the diffuse Night Sky Background
1613 and NSB (MMcPedestalNSB)
1614
1615 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1616
1617 - Introduced MMcRunHeaders which contains monte carlo run informations
1618
1619 - Added a 'Print'-Task (MPrint) which calls the Print function
1620 of a parameter container for each event
1621
1622 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1623
1624 - changes to be more efficient with root 3.02/06
1625
1626 - root 3.02/06 fixes:
1627 + the memory leak when reading MRawEvtData
1628 + loosing more time than necessary to update the progress bar
1629
1630 - MWriteAsciiFile is now capable of writing more than one container
1631 in a line. For example: To be able to write Monte Carlo and
1632 Hillas values (energy and alpha) in one line.
1633
1634
1635
1636 *** Version 0.5 (2001/11/06)
1637
1638 - Added new GUI functionality (Analysis)
1639
1640 - Added a camera display to be able to display events in the camera
1641 together with the calculated hillas ellipse
1642
1643 - Added a 'Clone'-Task (MClone) which can clone a parameter container
1644 object at any state of the analysis, so that the output are several
1645 states
1646
1647 - Fixed a bug in the collection area error calculation
1648 (Thanks to Ciro and Abelardo)
1649
1650 - Fixed a bug which causes merpp to crash in some environments
1651
1652 - Implemented auto enabling scheme for Branches to speed up reading
1653 a lot (see MReadTree and MTask)
1654
1655 - Fixed a bug in the Histogram classes which caused histograms to
1656 be written to a file by MWriteRootFile without request
1657
1658 - changed the object I/O from the old stylish root I/O to the new
1659 'auto evolution scheme' This was done only for classes which are not
1660 yet used in Monte Carlo files, so that these files are still readable.
1661
1662 - Added support for a progress bar in MEvtLoop and MReadTree
1663 (see the Analysis Window in Mars for an example)
1664
1665 - Fixed a bug in the package creation which disturbed the conversion
1666 between a mars version unpacked from a tar file and the repository.
1667
1668 - Changed the code to writer merpped (converted into root format)
1669 raw files, to get faster (around 10%)
1670
1671
1672
1673 *** Version 0.4 (2001/09/20)
1674
1675 - This release is made to compile on a root version >= 3.00
1676
1677 - Fixed a bug which causes MReadTree to read the first file only
1678
1679 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
1680
1681 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
1682
1683 - Added a task to write several container to a root file (MWriteRootFile)
1684
1685 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
1686
1687 - Added calculation of the collection area (MMcCollectionAreaCalc)
1688
1689 - fixed some bugs in the Hillas calculation
1690
1691 - added filters to be able to control the task execution dependent on
1692 a parameter (for example: the number of level 1 triggers in a MC-file)
1693
1694
1695
1696 *** Version 0.3 (2001/04/23)
1697
1698 - Many demo macros added
1699
1700 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
1701
1702 - Hillas Calculation added
1703
1704 - Standard image cleaning available
1705
1706 - MReadTree is now able to handle more than one file
1707 (Remark: of the same structure)
1708
1709 - Now we are able to display events in a first version of the
1710 Camera event display. To do this we must run the macro
1711 "macros/readCT1.C" to read data from CT1.
1712
1713
1714
1715 *** Version 0.2 (2001/01/24)
1716
1717 - First Implementation of a Gui to read the raw data. Start the
1718 gui with the command mars.
1719
1720
1721
1722 *** Version 0.1 (2000/12/20)
1723
1724 - First official release 0.1
1725
1726 - Changes:
1727
1728 + changed calling style of MRawPixelIterator from do...while to
1729 while-loop