source: trunk/MagicSoft/Mars/NEWS@ 7850

Last change on this file since 7850 was 7850, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 73.0 KB
Line 
1 -*-*- END -*-*-
2
3 *** Version <cvs>
4
5 - general: a lot of small changes to make the code compatible with
6 root 5.12/00 and gcc 4.1
7
8 - general: Fixed some warnings thrown if more warnings are switched
9 on in the compiler
10
11 - showplot:
12 + batch mode creation of image files now works with root 5.12/00
13 + added support for writing bmp (though it never produces
14 bmp which can be read by programs like xv or gimp)
15 + added support for xml
16 + added new option to start the display with a different size, by
17 --display-width=nnn or --display-height=nnn
18 + added options to define the canvas size when the display is started
19 --canvas-width=nnn or --canvas-height=nnn
20 the option can also be used for batch-mode conversion
21 + added an option which automatically fits the display size to the
22 desktop-size: --auto-size
23
24 - merpp: didn't recognize files with the extension .raw.gz - fixed.
25
26 - callisto: Callisto now raises an error if one of the input files could
27 not be opened.
28
29 - callisto: Updated absolute calibration constants (muon calibration)
30
31 - callisto: fixed a bug which caused the hi-gain saturation not
32 to be handled properly
33
34 - callisto fixed a bug which gave weird results if hi- and lo-gain
35 could not be extracted properly
36
37 - callisto: Fixed a bug regarding the use of the QE which doesn't
38 effect the result because the default is used anyhow.
39 (The bug was there since 14/07/2005)
40
41 - callisto: Changed the default for fgLoGainStartShift
42
43 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
44 factors to be 10 after the first calibration update.
45
46 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
47 was off by more than one slice (which gives wrong values for
48 pixels which have saturated the hi-gain) This was a problem
49 mainly for timing studies, not for the automatic standard analysis.
50
51 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
52 lo-gain pulse for data pulses if hi- and lo-gain have saturated
53 and both were extracted because the hi-gain was above the
54 LoGainSwitch.
55
56 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
57 lo-gain pulse position (after application of LoGainOffset, which
58 means in the ideal case it is 0) for data pulses if hi- and lo-gain
59 have saturated and both were extracted because the hi-gain was above
60 the LoGainSwitch.
61
62 - callisto: After extensive tests a new threshold level for determination
63 of the pulse position has been found at 50phe. This is due to the
64 fact that for lower pulses the arrival time changes its average
65 behaviour dramatically. It tends to the average of the extraction
66 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
67
68 - star: changed the fit for the effective on time such that initial
69 values are calculated automatically now instead of using build
70 in values. This makes the fit more indepedant of the underlaying
71 rates. With a test of ~350 sequences in the test database it could
72 be shown that the new fit gives the same result +/-1sek.
73 The highest deviation was +5s the lowest -10s. You can now control
74 the bahaviour with two resource values:
75 MHEffectiveOnTime.FistBin: 3
76 MHEffectiveOnTime.NumEvents: 12000
77 Use FirstBin=1 and NumEvents=120 to fit the effective on time
78 from the resulting gamma candidates
79
80 - star: The Center histogram in MHHillas is now by default displayed
81 with the colz draw-option
82
83 - ganymed: now pruduces valid error codes if failed
84
85
86
87 *** Version 0.9.6 (2006/05/24)
88
89 - general: changed the binning of the azimuthal profile of the camera
90 such that it is aligned with the 60deg boundaries.
91
92 - merpp: better handling of problems with the TH, TD part of the
93 CC-REPORT for files older than 200507190 and 200412210
94 respectively
95
96 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
97
98 - merpp: implementd latest changes in starguider reports (sinc 9th May)
99
100 - callisto: if an arrival time is extracted outside the fadc range is
101 was set to the boundary before. Now a random number is assigned
102 instead to avoid unfortunate coincidences of arrival times just
103 by this arbitrary value.
104
105 - callisto: added a new option to callisto.rc which allows
106 to set the maximum arrival time difference allowed for the
107 badpixel algorithm to determin whether a pixels belongs to a shower:
108 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
109
110 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
111 to 0.9 as suggested by Stefan due to a recent study on the fraction
112 of pixels surviving the image cleaning
113
114 - callisto: switched off error in case of "pulse is too much to the left"
115
116 - callisto: The extraction window is not adapted anymore. This means that
117 the pulse is extracted from the full range. The draw-back is that the
118 background (pedestal) will become slightly higher. Switching on/off
119 the PulsePosCheck in the callisto.rc only effects filling the
120 histograms.
121 WARNING: If the pulse is too much to the left data is calibrated!
122 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
123 in the database to make sure that your data is valid!
124
125 - star: Show also the number of stars correlated correctly by the
126 starguider
127
128 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
129 than one off-source region in wobble-mode. To use it add the following to
130 your ganymed_wobble.rc:
131 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
132 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
133 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
134 + Cut1.ThetaCut: None
135 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
136
137 - ganymed: in the case the latest report is older than a default (currently
138 one minute) and the current report will be skip the starguider
139 correction and calibration will be reset. The maximum age can be
140 setup from ganymed.rc by (minutes):
141 MPointingDevCalc.MaxAge: 1.5
142
143 - ganymed: A first implementation showing all size-bins for the theta-sq
144 resp. alpha-plots in a single tab automatically
145
146
147
148 *** Version 0.9.5.1 (2006/05/05)
149
150 - general: Added a new option "zdiff" to the Makefile which runs
151 "cvs diff" as "make diff" would do, but with compression
152
153 - general: accelerated MTFillMatrix (used for eample in all training
154 and optimization macros) by skipping some obsolete calles in the
155 eventloop the first and second loop could be accelerated by ~20%
156
157 - general: Added a missing feature in the MFilterList class which
158 prevented MFEnergySlope from working correctly in trainenergy.C
159
160 - general: Accelerated the random forest training and usage a bit
161
162 - merpp: Adapted to new raw data file format version 6
163
164 - merpp: fixed a problem with reading the starguider reports
165 after 6.3.2006
166
167 - callisto: At some times six pixels had to be exchanged manually in the
168 data. If the pixels to be swaped are both not found, an error was raised
169 and calibration was stopped. Now it is assumed they are intentially not
170 mapped and the Error has been changed to a Warning.
171
172 - star: Added new image cleaning based on the arrival time of the shower.
173 The new cleaning can be accessed using the parameter "Time" instead of
174 the the old one (like "Absolute) in the star.rc-file.
175 Recommended parameters:
176 + MImgCleanStd.CleanLevel1: 8.2
177 + MImgCleanStd.CleanLevel2: 5
178 + MImgCleanStd.CleanRings: 2
179 + MImgCleanStd.KeepSinglePixels: No
180
181 - star: Simplified the calculation of the effective on time. By letting
182 the fit start in the third bin the result should become more stable.
183 The fit quality is now ignored for the theta-plot which is not used
184 in the analysis later. Still better pre-cut which, for example,
185 remove events triggered by car-light (rate changing on a short
186 time-scale) are missing.
187
188 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
189 for optimization (kWeakSource) which is suggested by the Berlin
190 people for weak sources.
191
192 - macros: plotdb.C:
193 + if no dataset and no time-interval is given only sequences with
194 an effective on-time above five minutes are plotted anymore
195 + added a new tab "RelTime" displaying the relative on-time
196 (effective on-time divided by the observation time)
197
198 - macros: optim*.C: by skipping some obsolete calles in the eventloop
199 the optimization became a lot faster
200
201 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
202 To display them just delete the pads displayed on top.
203
204 - ganymed: fixed a bug which could cause strange behaviour in wobble
205 mode if no starguider information was available due to an incorrect
206 initialization of the starguider calibration
207
208 - ganymed: The scale region in the False Source Plot (MHDisp) can now
209 be changed from within the plot. It can also be setup from the
210 resource file using:
211 + MHDisp.fScaleMin: 0.325
212 + MHDisp.fScaleMax: 0.475
213
214 - ganymed, showplot: Fixed a problem with the fit to the off-data
215 (HistOff) which could cause a time lag or an inifinite loop.
216 The bug did not effect the results at all.
217
218 - sponde: Added a new tab showing the effective collection area after
219 trigger (including the software trigger)
220
221 - sponde: MMcSpectrumWeight has a new option which allows to define
222 the scaling factor not by the integral of the events but at
223 a defined energy:
224 e.g. MMcSpectrumWeight.NormEnergy: 200
225
226 - MTFillMatrix, sponde: by skipping some obsolete calles in the
227 eventloops the loop could be accelerated by ~20%
228
229
230
231 *** Version 0.9.5 (2006/03/13)
232
233 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
234 and added the standard Disp-parametrization
235
236 - macros: added a new macro datacenter/macros/plotstat.C allowing
237 to plot statistics about the data processing
238
239 - macros: added a new macro to plot the muon correction coefficients
240 versus period (macros/plot/mucal.C)
241
242 - showplot: path inflation for ganymed files was broken
243
244 - callisto: Fixed an important bug. When the number of saturating pixels
245 were calculated the bad pixel information already available from the
246 calibration was ignored. This yields wrong values in case pixels
247 are broken and saturate all the time or randomly.
248
249 - callisto: Updated Muon calibration constants. Spline data now also uses
250 different values for different periods
251
252 - star: The time-evolution shown in the effective on-time plot now displays
253 the axis range (if there are no holes it should be similar to the
254 effective on-time)
255
256 - star: Added two new image parameters:
257 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
258 the three pixels next to the center of gravity and the size
259 + MNewImagePar.fConcCore: The ratio of the signals of all
260 pixels inside or touching the ellipse and the size
261
262 - ganymed: now stops in requested source isn't found in catalog file
263
264 - ganymed: Many improvements to the phi-plot in wobble mode:
265 + with a template the ideal background is displayed
266 + a possible camera inhomogeneity is taken into account
267 + the anti theta cut is better supported
268 + the phi cut is automatically calculated from the theta cut
269 See the examples in ganymed_wobble.rc for more details.
270
271 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
272 times the bin-width instead of the absolute energy
273
274 - ganymed: New cuts for on/off and wobble mode
275
276 - ganymed: The smearing of the False Source plot has been increased
277 to 0.06
278
279 - ganymed: The starguider calibration can now be changed from the
280 resource file.
281 See the examples in ganymed*.rc for more details.
282
283 - ganymed: added a new option for on-/off-observations
284 MJCut.RandomSourcePosition
285 If switched on the distribution of observation time of the source
286 position in the camera is calculated from the on-data and randomly
287 applied with this distrbution to the off-data.
288
289 - ganymed: by skipping some obsolete calles in the eventloop the
290 first and second loop could be accelerated by ~20%
291
292 - ganymed: The default in ganymed_onoff.rc is now to determin the source
293 position in the off-data randomly according to its distribution in the
294 on-data.
295
296
297
298 *** Version 0.9.4.3 (2006/02/13)
299
300 - general: Fixed a bug in most of the programs which prevented the
301 compile date in the startup message to be displayed
302
303 - general: Simplified program calls. The following abbreviations
304 are now possible:
305 showlog callisto 55599
306 showplot signal 55599
307 star 55599
308 callisto 55999
309 ganymed 2
310 In this cases the corrsponding root-, log-, sequence- or dataset-
311 filename is automatically compiled using the default datacenter
312 paths ("/magic/*")
313
314 - general: Fixed a long outstanding bug which made axis tick marks
315 disappear if MDataFormula was used (eg. abs(x))
316
317 - general: Updated MMath with new functions to calculate the results of
318 a exponential, logarithmic and powerlaw fits analytically.
319
320 - general: Updated some macros with comments:
321 + macros/optim/optimdisp.C
322 + macros/optim/optimenergy.C
323 + macros/optim/optimwobble.C:
324
325 - general: MTFillMatrix (the class to fill one or two MHMatrix from
326 files) now allows adding a pre-cut like in the optimization. E.g. this
327 is useful to perform g/h-separation cuts before training the random
328 forest.
329
330 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
331 correctly assigned in the raw data assignement table. A fix to correct
332 the assignment tabel have been implemented.
333
334 - general: MAstroCatalog now allows rotating of the sky-grid and stars
335 by 90, 180 and 270 deg.
336
337 - general: the macro plotdb.C now allows to highlight sequences belonging
338 to a datset. For more details see the descritions in the macro.
339
340 - StatusDisplay: Fixed the algorithm to calculate the size ratio
341 of the display, it gave wrong results espacially for big sizes.
342 Now the embedded canvas should always have a ratio width/height=3/2.
343 The "Size" options have been updated with values fitting the 3/2
344 size ratio.
345
346 - RanForest:
347 + Updated the random forest classes to support also the
348 regression method implemented by Thomas H.
349 + added new tutorial macro how to train the random forest
350 for energy estimation (macros/optim/rfenergyest.C)
351 + new classes to train the random forest (still in development)
352 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
353 + new tutorial macros for random forest training in macros/train
354 trainenergy.C, traindisp.C, trainseparation.C
355
356 - mars: now allows to setup a cut in the resource file mars.rc to choose
357 the events to be displayed, eg:
358 Cut.Condition: {0} && {1}
359 Cut.0: MHillas.fSize>100
360 Cut.1: MHillas.fSize<900
361
362 - merpp: Made aware of the new .rep format 200510250. This includes
363 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
364 the discriminator thresholds (MCameraTD) and the disciminator
365 delays (MCameraTD). All of them come with the CC report and are therefor
366 written to the CC tree.
367
368 - callisto: fixed a bug in the calculation of the arrival times in
369 the Digital Filter. They were all shifted by the same amount
370 fHiGainFirst. This caused an offset in the order of the position of
371 the left border of the extraction window in the times calculated
372 from high-gain and from low-gain. The bug effected only the absolute
373 arrival times. The bug was there since 30.1.2005.
374
375 - callisto: Changed the ExtractionWindow for the pulse position check
376 such that the camera inhomogeneity becomes as less as possible and
377 comparable to the pulso position check switched off. More details
378 on the study will be given at our result web-page.
379
380 - ganymed: ganymed.rc, ganymed_onoff.rc:
381 changed to new cuts trained with 1ES1218 and Crab-data
382 for maximum sigma*log10(excess)
383
384 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
385 a new option was implemented to estimate Disp (CalcDisp)
386
387 - ganymed: Implemented two new options which allow
388 to overwrite the default path to search for the sequence files
389 --ins=/magic/sequences
390 and where to search for the image data
391 --ind=/magic/data/star
392
393 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
394 dx/dy from the resource file by
395 MSrcPosCorrect.Dx
396 MSrcPosCorrect.Dy
397
398 - ganymed: fixed reading the source catalog. Only as many chars
399 as the requested source name had were compared (If a source
400 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
401 were requested it could happen that the coordinates of
402 "1ES1218" were read) The source coordinates are now printed
403 in addition to its name to the logging output.
404
405 - ganymed: changed the background fit in the case of a ThetaSq function
406 from a polynomial to a exponential, this should give a big improvement
407 for on-only analysis'
408
409 - ganymed/sponde: Calculation of the error of single size-/energy-
410 bins now uses Li/Ma (5) instead of LiMa (17)
411
412 - sponde: Added a plot E^2*dN/dE
413
414 - sponde: The energy estimator plot should now show values like
415 they are commonly used.
416
417 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
418 (a powerlaw with cutoff didn't work before)
419
420
421
422 *** Version 0.9.4.2 (2005/10/01)
423
424 - general: added new tutorial macro macros/tutorials/threshold.C:
425 how to calculate the threshold
426
427 - general: added a new game. Start it from the interpreter with
428 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
429 and MagicReversi)
430
431 - general: neighbor pixels in MGeoms are now sorted clockwise
432
433 - merpp: made aware of new format 20050829-0
434
435 - callisto: New scale factors from muon analysis, stored in new
436 resource file resources/calibration.rc
437
438 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
439 the eventloop if something went wrong. This is necessary for the
440 automatic processing
441
442 - callisto: Implemented a new treatment for the time information
443 developed by S.Ruegamer, this should give much better response than
444 the old very primitive algorithm. This is especially important
445 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
446 treatment was buggy! As neighbor pixels to interpolate the
447 arrival times always the pixels 0 to 5 were taken)
448
449 - callisto: In addition to the new treatment of arrival times the
450 decision of the treatment whether a pixel contains shower
451 information or not is used to improve the signal interpolation
452 further. Previously interpolated pixels showed a non-zero signal
453 do the peak searching signal extractors. Having a signal pixel
454 beside raised the signal above the cleaning level. Thus the
455 pixel survived cleaning to often but with a too low mean signal.
456 By replacing empty pixels with a gaus (mean and rms from the
457 corresponding Area entries in MPedPhotCam) this effect can
458 be supressed.
459
460 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
461 got lost when the events were stored by the calibration... fixed.
462 (This was no problem for normal image cleaning because the pixel
463 content was artificially set to 0 not surviving standard cleaning
464 algorithm)
465
466 - callisto: Fixed a bug which caused the random and peak-search pedestal
467 extracted with an extractor to be exchanged for the first (roughly)
468 500 events (*Extractor and *ExtractorRndm).
469 (They were simply exchanged in callisto.cc) This bug might have been
470 introduced in Mars 0.9.4 when the order of calculation of the two
471 types of pedestal in callisto got exchanged. The bug only effects
472 the first seconds of data of each sequence.
473
474 - star: Taking the arrival time of Muons into account the calculation
475 of the parameters could be made independant of the noise
476 (pedestal rms). The dependance was due to the bias of the peak search
477 extractor. Now only a ZA dependamcy is left which is not yet fully
478 understood.
479
480 - ganymed: The sequences were still not sorted correctly in any case,
481 because they were sorted by the full qualified path name. Now they
482 are sorted by their sequence number.
483
484 - ganymed: new values for the spark-event-cut
485
486 - sponde: required missing MEnergyEst from ganymed.root... fixed.
487
488
489
490 *** Version 0.9.4.1 (2005/08/18)
491
492 - callisto: fixed some problems with the calibration in case of
493 inteleaved events. Therefor the final and some intermediate
494 fits are skipped which would take place on partly filled #
495 histograms and gave wrong results or failed completely.
496
497 - callisto: If the intermediate finalization of the histograms
498 calculating the mean charge of the calibration signal fails
499 it is counted now and printed in PostProcess of MCalibCalcFromPast.
500
501 - ganymed: Fixed some bugs which caused problems in On-only mode.
502 Still the false source plot doesn't give reasonable results.
503
504
505
506 *** Version 0.9.4 (2005/08/05)
507
508 - general: Fixed the ZA binning. It did not correctly fit the
509 MC binning
510
511 - general: Added a class to correct for the missfocussing in
512 April (MSrcPosCorrect)
513
514 - general: Random Forest energy estimator should now work properly
515
516 - general: MHCamera now displays the profiles in deg instead of mm
517
518 - general: MH::SetPalette offers a lot of new palettes
519
520 - general: MHillas - the case of CorrXY==0 is now handled properly
521
522 - general: implemented the possibility to change the line and
523 marker style of a sky-grid drawn by MAstroCatalog
524
525 - general: Runs in sequences and datasets are now automatically
526 ordered (it is assumed that the order of their filenames correctly
527 represents the order of observations) to ensure correct reading
528 of the subsystem data
529
530 - general: Runs cannot be added to a sequence twice anymore. Also
531 Sequences cannot be added twice anymore to a dataset.
532
533 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
534 It gave wrong results by 1./2pi
535
536 - showplot: got a new option to start a root interpreter, too
537
538 - mars: now displays a rough estimate of Disp and the third moment
539
540 - mars: now displays the event time MTime if available
541
542 - mars: show muon parameters graphically
543
544 - mars: now the file to open can be given as commandline
545 argument
546
547 - merpp: Added support for new arehucas version >= 200507190
548 implementing values for three temperature sensors in the
549 counting house (MCameraAUX) and the name of the HV settings file
550 (MCameraHV).
551
552 - merrp: Also fixed some problems with wrong versions numbers stated
553 by arehucas and implemented some fixed for old versions (<200407070)
554
555 - callisto: MCalibrationHiLoCam can now be printed from its context
556 menu, eg in the TBrowser
557
558 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
559 - 1.39 (MExtractTimeAndChargeSpline)
560 - 1.40 (MExtractTimeAndChargeDigitalFilter)
561 This is important mainly for timing studies.
562
563 - callisto: Changed limits in MHCalibrationChargeCalc from
564 - -100.125 to -98 (fgChargeHiGainFirst)
565 - 1899.875 to 1902. (fgChargeHiGainLast)
566 - -100.25 to -99 (fgChargeLoGainFirst)
567 - 899.75 to 901. (fgChargeLoGainLast)
568 Introduced new limits:
569 - fgNumLoGainBlackoutLimit: 0.05
570 - fgLoGainBlackoutLimit: 3.5
571 - fgLoGainPickupLimit: 3.5
572
573 - callisto: The handling of automatic weights for the digital filter
574 has been improved. There are now new calibration weights special
575 for Monte Carlo calibrations.
576
577 - callisto: Updated Muon scale with latest results (1% difference
578 for most data, 5% for Mar/Apr'05)
579
580 - callisto: use a new criterium to exclude bad pixels: If the high-gain
581 was saturated and the blackout-events in the low-gain exceed the
582 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
583 This excludes those pixels which have a saturating high-gain
584 channel, but the low-gain switch does not switch often enough
585 to make the distribution reliable.
586
587 - callisto: fix a bug counting the number of saturated events. Up to now,
588 the number of saturated slices was counted (which is one for a not too
589 high number), but for some (pathological) pixels, many more slices
590 saturated and produced wrong limits.
591
592 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
593 + MCalibrationRelTimeCam.CheckFitResults: Yes
594 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
595 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
596 + MCalibrationRelTimeCam.CheckOscillations: Yes
597
598 - callisto: introduce max. number of events for intercalibration,
599 the rest gets skipped. Default: 4096
600 The calibration causes too many un-reliable pixels if more
601 than about 5000 events are treated (@500 Hz) because of the
602 mode hopping of the VCSels. However, in the past, some
603 calibration runs have been taken (erroneously) with more
604 than 5000 events, especially the intensity scans where
605 a good precision is needed.
606
607 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
608 photo-electrons for the spline extractor by 1-2% (correctly).
609
610 - callisto: The intercalibration is now done using a full f-factor
611 method instead of a simple update. This makes things slower but
612 more reliable in terms of gain-fluctuations and sudden VCSEL gain
613 changes.
614
615 - callisto: MPedestalY3 now uses the same extraction range as the data
616 as calculated by MPedestalY2
617
618 - callisto: A check of the fraction of allowed unsuitable (10%) and
619 unreliable (30%) pixels has been addded when the conversion is
620 calculated from interleaved events
621
622 - star: fixed a bug which caused MEffectiveOnTime containers not to
623 be written. In the worst case they were skipped almost all, in the
624 best case they were all ok. It depends on how often the new value
625 was assigned just with an event which was skipped later by another
626 task
627
628 - star: new histograms MHPointing and MHRate
629
630 - star: New tab (Currents) displaying the time evolution of the mean
631 DC currents
632
633 - star: New tab (MeanRms) displaying the time volution of the mean
634 Pedestal Rms
635
636 - star: Output now contains MReportStarguider
637
638 - star: Improved muon analysis. Due to the absense of a constant
639 for the gaus fit for arc width and the fact that the arcwidth
640 plot was a histogram instead of a profile the resulting psf
641 became pedestal rms dependant
642
643 - ganymed: added new plot (MHPhi) for wobble mode as described in
644 http://www.astro.uni-wuerzburg.de/results/ringmethod/
645
646 - ganymed: corrects now (correctly?) for the misspointing in
647 May/April 05
648
649 - ganymed: Two new default templates for ganymed.rc are avilable:
650 ganymed_onoff.rc and ganymed_wobble.rc
651
652 - ganymed: The first version of MFMagicCuts has been released
653
654 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
655
656 - ganymed, sponde: There are two new options to determin the number
657 of bins for the signal region (NumBinsSignal) and the number of
658 total bins (NumBinsTotal) in the MHThetaSq histogram
659
660 - ganymed: optimized palettes for MHDisp
661
662 - ganymed: Fixed an important bug when using ThetaSq as fit function:
663 The result for the sigma of the gauss(sqrt(x)) fit was a factor
664 sqrt(2) to large
665
666 - ganymed: The false source plot (MHDisp) is now based on Disp
667 and a background model determined in the first loop is
668 subtracted
669
670 - ganymed: MFMagicCuts are now available in the cvs. The correct
671 solution for the disp ambiguity problem is now calculated using
672 the third moment. The third moment cut therefor is skipped.
673
674 - ganymed: Output now contains "Disp [MParameterD]" which sign is
675 already determined by the third moment along the major axis and
676 so its actual sign is aligned along the major axis of the shower.
677
678 - ganymed: If starguider data is available it is taken into account
679 when calculating the source position. This is especially important
680 for wobble data at high zenith angles and culmination data.
681
682 - ganymed: If available the starguider data is taken into account as
683 good as it is possible without a starguider calibration. To switch
684 it off add
685 MPointingDevCalc.MaxAbsDev: -1
686 to your ganymed.rc
687
688 - sponde: the zenith angle distribution is now weighted instead of
689 choosen by default. This gurantees higher statistics in the highest
690 and lowest energy bins. To switch this behaviour off use...
691
692 - sponde: now automatically displays the energy threshold
693
694
695
696 *** Version 0.9.3 (2005/06/03)
697
698 - general: MMcEvt now derived from MMcEvtBasic which should
699 have no influence on compatibility with older camera files
700
701 - general: Implemented a new option to MReadReports which allows
702 to force reading of the first event of some trees (eg. Drive-tree)
703 before any other tree.
704
705 - general: Made a fix to MPointingPosCalc which assumes that the
706 run-type is real-data if Process is called before ReInit, such
707 that also the very first Drive-events in a run are treated
708 correctly.
709
710 - shoplot now displays the filename in the title bar of the window
711
712 - merpp: new options: --auto-time-start --auto-time-stop which
713 allow to cut updating with slow-control at the start- or
714 (previousle --auto-time only allowed: and) stop-time of
715 the run stored in the runheader.
716
717 - callisto: changed default of fgFallTimeHiGain in
718 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
719 already set as default in callisto_Dec04Jan05.rc
720
721 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
722 now changes the filename for new weights automatically for
723 cosmics, MC and for different calibration colors.
724
725 - callisto: a problem with the order of some code cause the
726 name of the weights file in MPedestalY2 to be ignored.
727 Wrongly the calibration_UV weights were used instead
728 of the cosmics weights set in callisto.rc.
729
730 - callisto: should allow ct1 pulser data when the color is
731 explicitly set also for pretty new runs
732
733 - callisto: a new option (MCalibrateData.ScaleFactor) allows
734 to introduce an additional scale factor (should be around 1)
735 to adapt for slight deviations in different extractors from
736 the MC calibration. For MC calibrations the scale factor
737 is fixed to 1
738
739 - callisto: MFCosmics should handle very high signals a bit
740 more accurate now
741
742 - callisto: when calculating the mean pedestal rms for different
743 pixel sizes or sectors also kUnsuitableEvt is now taken into
744 account - not only kUnsuitableRun
745
746 - callisto: '-raw' option is now the default
747
748 - callisto: A dead pixel check has been implemented in MJPedestalC2.
749 This has the advantage that mean values in the calibration (eg
750 arrival times) are calculated more accuratly.
751
752 - callisto: In the resource file callisto_Dec04Jan05.rc
753 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
754
755 - callisto: new Hi-/Lo-Gain intercalibration constants
756 hilocalib_sp1.root and hilocalib_sp1_mc.root
757
758 - callisto: changed default for MJPedestalY2.MaxEvents
759 from 2000 to 5000 like in callisto_Dec04Jan05.txt
760
761 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
762 has changed from 9.0 to 6.0. This is necessary to exclude two very
763 ringing pixels in September which - when kept - destroy the image
764 cleaning around them (Markus G.)
765
766 - callisto: (!) The Muon analysis of all data taken so far has
767 suggested that different extractors give slightly different
768 absolute results after calibration, due to there different
769 handling of the calibration- and cosmics pulse shape. Although
770 the over all calibration seems to be a bit to pesimistic (or
771 the MC seems to be a little bit - 3-5% - too much attenuated).
772 There for correction factors have been introduced which correct
773 the calibration constants by
774 0.956937799 for Digital Filter (callisto.rc)
775 and
776 0.904159132 for Spline (callisto_Dec04Jan05.rc)
777 calibration. The main advantage is, that both data types can
778 be easily analysed together and compared to the same MC sample.
779 The factors are choosen such, that the reference is now a
780 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
781
782 - star: fixed a bug which caused the first bin of the histograms
783 vs time to disapear in PostProcess. This gave wrong results
784 on the screen. The output and all following programs not
785 directly accessing the histograms haven't been affected
786
787 - star, ganymed: Made sure that always the first Drive-tree event
788 is read and Processed before the first data event was read.
789
790 - ganymed: implemented the possibility to replace the standard
791 false source plot with a different one. For example: If
792 you want to use a Disp based FS plot use the resource:
793 NameHistFS: MHDisp
794 For details about the requirements of these plots look
795 at the corresponding classes
796
797 - MJOptimize: For On/Off and Wobble optimization MJOptimize
798 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
799 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
800 case MAlphaFitter is setup correctly. For On-Only optimization
801 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
802 RunOn() instead of Run(). For energy estimation MJOptimize
803 has been replaced by MJOptimizeEnergy
804
805 - sponde: The input MC spectrum can now be weighted to fake a
806 different spectrum. This is done via MMcSpectrumWeight. For
807 more details see the class description and sponde.rc
808
809 - sponde: The paremeter comparsion plots are not scaled by
810 their entries anymore. Instead the MC plot is scaled by using
811 the result spectrum of the analysis. If the input MC spectrum
812 and the result spectrum has different slopes the absolut
813 normalization is normally wrong.
814
815
816
817 *** Version 0.9.2 (2005/05/20)
818
819 - general: Changed the default paths for calibrated data and image
820 files. (The implemented access to these files doesn't yet exist)
821
822 - general: support for MRunIter has been removed from the job classes
823 (use the setter functions of MSeqeunce instead)
824
825 - general: ProcessFile has been renamed to Process in all job classes,
826 because ProcessFile is missleading
827
828 - general: The storage of the palette in MHCamera is now possible
829
830 - general: new bits describing unsuitable and unreliable pixels have
831 been introduced in MBadPixelsPix: kPreviouslyExcluded,
832 kDeadPedestalRms, kFluctuatingArrivalTimes
833
834 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
835 versions newer than V200404070
836
837 - general: support for cc file versions newer than V200504130. Added
838 support for active loads (MCameraActiveLoad) and central pixel
839 (MCameraCentralPixel)
840
841 - general: added new histograms for image parameters versus size
842 (MHVsSize)
843
844 - general: The eventloop now automatically calls PrintStatistics
845
846 - Status Display: Improved support for printing:
847 + A default can now be set in .rootrc (for more details see
848 MStatusDisplay::PrintPS)
849 + A print dialog is opened so that printer and command line
850 can be canged
851
852 - showlog: improved such that it handles different verbosity levels
853 more accurate now. This mean you can suppress output when
854 using showlog.
855
856 - showplot: improved
857 + The new graphics formats have been implemented
858 (pdf, svg, png, jpg and xpm)
859 + Implemented an interface for printing. Because you can change
860 the printing command from the command line you can use all
861 the nice postscript tool. To print a booklet for example call:
862 showplot -b --print --print-cmd="cat %f" filename.root | lpr
863 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
864 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
865
866 - callisto: fixed a bug in the recognition of the calibration bit
867 pattern. Concerns only intensity calibration. (The strength of the
868 intensity has been updated in some cases)
869
870 - callisto: add a filter against PIN Diode events when running over
871 calibration runs since some of the recent calibration runs have
872 been taken with Pin Diode.
873
874 - callisto: added support for the runs 39942, 39944, 44834, 39941,
875 39943, 44833 in the calibration (MCalibColorSet)
876
877 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
878 been set to 1e-18 in callisto_Dec04_Jan05.rc
879
880 - callisto: in callisto_Dec04Jan05.rc: set value for
881 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
882 statistics for the calculation of the mean pulse time
883 of the cosmisc
884
885 - callisto: the charge limit in the calibration has been raised
886 from 2.5 to 4.5
887
888 - callisto: new setup read from callisto.rc
889 + MCalibCalcFromPast.fNumEventsDump
890 + MHCalibrationChargeCam.NumHiGainSaturationLimit
891 + MHCalibrationChargeCam.NumLoGainSaturationLimit
892
893 - callisto: MExtractTimeAndChargeSpline extractor:
894 + The integration ranges were shifted by 0.2 FADC slices to the right.
895 + unreliable handling of floating point values caused different
896 results on different platform or with different compiler options:
897 The new algorithm is numerically exact and more accurate because
898 it doesn't calculate the integration position by multiple times
899 adding the step-size (which results in numerical uncertanties
900 exspecially if multiplied with large numbers)
901 + A lot of fixes have been introduced which effects integrating the
902 spline at the edges of the valid range. In this case any memory
903 was randomly accessed. This behaviour can be tested replacing
904 all MArrayF by TArrayF which perform a range check (but of course
905 they are a lot slower)
906 ! No result obtained with the Spline before can be trusted! Due to
907 random memory access it might by completely random!
908
909 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
910 + extraction range in the high gain to 4.
911 + weights file to cosmics_weights46.dat
912
913 - callisto:
914 + introduce the check for fluctuating arrival times.
915 + set charge limit to from 2.5 to 4.5
916 + introduce asymmetric exclusion due to "deviating number of phes":
917 Default: -9.0 +4.5
918 + make deviating number of phes unsuitable (see David's findings).
919
920 - callisto: fixed the display of unsuitable pixels. The old change
921 to a real profile in MHCamera broke it.
922
923 - callisto: The cosmics filter is used in MJCalibration now
924 independant of the pulser color (formaly it was used only for
925 CT1-pulser data). The threshold of number of max empty pixels
926 has been raised from 2% to 5% in MJCalibration. The maximum
927 fraction of rejected event is 50% otherwise the calibration has
928 failed. The filter now ignores unsuitable pixels.
929 Setup the filter from callisto.rc using "ContCosmics"
930 (see MFCosmics::ReadEnv)
931
932 - callisto: changed default for fgOffsetFromLogain back
933 from -2.8 to -1.8 in digital filter.
934
935 - callisto: for the common extractors
936 + MExtractFixedWindow
937 * MExtractTimeAndChargeSlidingWindow
938 * MExtractTimeAndChargeSpline
939 * MExtractTimeAndChargeDigitalFilter
940 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
941 and fResolutionPerPheLoGain
942
943 - callisto: Updated the hi-/lo-gain intercalibration constants
944 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
945 hilocalib_df6.root
946
947 - callisto: The default lo-gain extraction window for the
948 MExtractTimeAndChargeSlidingWindow extractor has been increased
949 from 6 to 8 to take the stretch of the pusle into account
950
951 - callisto (!!!): fixed an important bug in the setting of the
952 incoming pedestal pointer to the signal extractor extracting
953 pedestals. This bug caused the pedestals not to be subtracted
954 correctly in the calibration afterwards. The effect was about 10%
955 too high conversion factors for the digital filter and the spline
956 and more than 40% for the sliding window.
957 The bug existed since end of February! (Markus G.)
958
959 - star: added muon support to star. A new tab "MHMuonPar" is
960 displayed. The lower right plot is an estimate of the point spread
961 function. A reference value is displayed. To get the real PSF
962 you must compare with MC. The setup for the muon analysis
963 is done in star.rc. More informations can be found in
964 MHSingleMuon and MHCalibParCalc
965
966 - star: The weather data is now displayed in star
967
968 - star: MEventRateCalc handles the calculation of the event rate more
969 accurate now in case of the start of a new run inside a sequence
970
971 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
972 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
973 changed only minimally
974
975 - ganymed: (MJCut and MJOptimize) now displayes the number of
976 excess events versus size. The energy estimation is done in
977 MJSpectrum (sponde)
978
979 - ganymed: got support for using other variables than Alpha, eg. Theta.
980 Therefor you need a class deriving from MHAlpha which supports
981 this variable (one is already existing: MHTheta, which is now the
982 default in ganymed). It is setup through ganymed.rc
983
984 - added a full featured spectrum program (sponde) which reads
985 ganymed output and monte carlos and compiles a spectrum
986
987
988
989 *** Version 0.9.1 (2005/04/14)
990
991 - Fix bug on the arrival time reconstruction when using Digital
992 Filter (in some marginal cases (10%) times were reconstructed shifted
993 by 0.2 slices)
994
995 - all executables now return 2 where in previous versions -1 has
996 been returned (gave problems with shell-scripts)
997
998 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
999 also done with a intercalibration input file
1000
1001 - a bug in the time fine adjustment of the digital filter has been fixed
1002
1003 - a lot of small fixes to calling TPad::Divide with a margin==0
1004
1005 - MStatusDisplay now shows the memory usage
1006
1007 - added a memory leak statistic after the eventloop
1008
1009 - MHadronness replaced by MParameterD
1010
1011 - MEnergyEst replaced by MParameterD
1012
1013 - wobble mode can now be switched on from the data-set
1014
1015 - switched on bad pixel detection for a pedestal level
1016 which is more than 5 times the variance
1017
1018 - Fixed default paths to be correct for the new data center
1019
1020 - Fixed handling of drive data. The pointing position in now
1021 copied to MPointingPos inside star for real and MC events
1022
1023 - made sure, that the sequences in a dataset are sorted by
1024 their number to ensure the correct synchronization
1025
1026 - added all resource files necessary to handle spline extraction
1027 of signal for the late 2004 and the early 2005 data
1028
1029 - update the reference lines for the december data
1030
1031 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1032 This is important for the Dec. and Jan. data where the calibration
1033 pulse position changes much.
1034
1035 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1036 filter. This corrects only an defective extraction of the MC at
1037 low-gain signals lower than 90 phes.
1038
1039 - fixed some slowdown in calibrating data with interleaved events from
1040 Jan and Dec. As a workaround made the pretty palette the default.
1041 The inverse Deep Blue Sea has a bug which slows down long calibration
1042 runs a lot.
1043
1044 - implemented new values from new starguider report as defined
1045 in TDAS00-07 V7.1 (eg SkyBrighness)
1046
1047 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1048 in starguider report (If you merpp the same reports with this version
1049 you'll get the correct units (arcmin) but a different result
1050 than with old versions (wrong units))
1051
1052 - Now the status display can also write PNG, JPEG and XPM (other file
1053 formats are still unsupported by root)
1054
1055 - added a lot of scripts and macros in directory datacenter used
1056 for automatic processing
1057
1058
1059
1060 *** Version 0.9 (2005/03/23)
1061
1062 - Calibration is now done autmatically into photo-electrons like
1063 decided by the Collaboration Board
1064
1065 - Reference lines in the display can be read from resource file
1066
1067 - Interlaced calibration events can be handled by callisto
1068
1069 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1070 and applied in callisto.
1071
1072 - class MJCalibTest can be called by callisto
1073
1074 - callisto can now run with three data types: rawdata, rootdata, MC
1075
1076 - added two classes mreport/MReportStarguider.cc and
1077 mreport/MReportStarguider.h for implementing starguider-data
1078
1079 - the output of merpp-update now contains starguider information:
1080 MReportStarguider and MTimeStarguider
1081
1082 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1083 values were lower than they should. This was more visible for high
1084 energy (Size) events.
1085
1086 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1087
1088 - added a new loop to callisto to support the correct extraction of
1089 the pedestal and pedestal rms through the signal extractor
1090
1091 - added class to perform fourier tranformation of a hexagonal structure
1092 (MHexagonalFT)
1093
1094 - added class to perform fourier tranformation of a hexagonal structure
1095 in a tasklist (MHexagonalFTCalc) example: hft.C
1096
1097 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1098 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1099 small pixels, example: extendcam.C
1100
1101 - added possibility to write data to memory (TTree) using MWriteRootFile
1102
1103 - added possibility to read a TTree stored only in memory by MReadTree
1104
1105 - new classes to deal with the interleaved calibration events:
1106 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1107
1108 - implemented filters to callisto to skip calibration events
1109
1110 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1111 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1112 the slices by statistics
1113 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1114 signal extractor without randomization
1115 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1116 with the signal extractor with randomization (extraction window is
1117 randomly fixed)
1118 The three kind of pedestal is not yet implemented (for speed reasons) as
1119 long as nobody really needs it:
1120 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1121 extracted with the signal extractor with randomization
1122
1123 - callisto now finds the pulse position in the data automatically
1124
1125 - implemented data reduction in calibrated data by reducing the precision
1126 of the stored floating point values (pedestal, rms and signal) to
1127 roughly 0.5%
1128
1129 - fixed showplot to make file format conversion (eg. converting a
1130 status display stored in a root file into a postscript file) in
1131 batch mode possible:
1132 showplot -b --save-as-ps[=outfile.ps] infile.root
1133
1134 - Allow class names as part of filter rules, eg
1135 (MFSupercuts) && (MHillas.fSize>100)
1136
1137 - fixed a lot of stuff to allow all programs to process MonteCarlo
1138 camera files.
1139
1140 - enhanced possibility to debug reading of resource file
1141
1142 - MDataChain should handle priorities of operator more
1143 accurate now
1144
1145 - completely revised the container in which the signal is stored
1146 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1147 * the new implementation is faster and
1148 * needs less storage space
1149
1150 - FIRST version which can process Monte Carlos through the
1151 whole chain of programs (callisto, star, etc)
1152
1153 - implemented new image parameters for the border length of
1154 the shower image (MNewImagePar2)
1155
1156 - implemented wobble-mode in ganymed
1157
1158 - new class (MJOptimize) taking care of all optimization processes
1159
1160
1161
1162 *** Version 0.8.6 (2004/10/05)
1163
1164 - New combined signal and time extractor
1165 MExtractTimeAndChargeDigitalFilter
1166
1167 - The Report for the trigger section in the CC run summary has been
1168 updated, and now the IPRs (Individual Pixel Rates) are available.
1169
1170 - new macros for database interaction: filldotrun.C, filldotrbk.C
1171
1172 - added new program which can convert colored output which was redirected
1173 into a file back into colored text (for example to display it with
1174 more): showlog
1175
1176 - added new program to display an MStatusArray of plots (stored with
1177 MStatusDisplay) from a file: showplot
1178
1179 - Added support for Sequences (MSequence). Sequences are blocks of run
1180 files containing the same calibration and belonging to the same
1181 source
1182
1183 - Added a new task (MTaskEnv) which can be used in setup files to switch
1184 between different tasks (for example to choose a signal extractor)
1185
1186 - Implemented automatic file splitting in MWriteRootFile
1187
1188 - After image cleaning an island index is assigned to all used pixels.
1189 The index corresponds to the order of the islands in size.
1190
1191 - added a cleaning which takes signal height _and_ arrival time into
1192 account: probability cleaning (for more details see MImgCleanStd)
1193
1194 - added a cleaning which takes takes the absolute number of photons
1195 times the area ratio as cleaning level
1196 (for more details see MImgCleanStd)
1197
1198 - Changed calculation of image parameters such, that it can be done
1199 for all used pixels or the pixels with a defined island index only
1200
1201 - implemented new image parameters displaying the number of islands,
1202 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1203
1204 - event display in executable changed to support also calibrated files
1205 (done with MJCalibrateSignal)
1206
1207 - added program doing the calibration and the signal extraction
1208 and signal calibration: callisto Most part of the setup is done
1209 by a resource file: callisto.rc
1210
1211 - implemented support for pixels with negative IDs (Raw file format
1212 version 4)
1213
1214 - implemented an new option in merpp (--auto-time) to get the time
1215 range for cc and/or caco data from the run header of the raw data
1216
1217 - New star-program (star and MJStar). Taking calibrated data from
1218 callisto/MJCalibrateSignal as input. The setup is done through
1219 a resource file: star.rc
1220
1221 - Added possibility to setup the eventloop in the mars-executable
1222 Camera Display by a resource file: mars.rc
1223
1224 - The the mars-executable Camera Display can now also read
1225 calibrated data files written by callisto/MJCalibrateSignal
1226
1227 - Added a new class which can calculate the source position in
1228 the camera from a pointing model known to be correct and
1229 the pointing model used for observations (MSrcPosFromModel)
1230
1231 - added a new version of the class calculating the effective on-time
1232 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1233 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1234 MHTimeDiffTheta.
1235
1236 - added the possibility to count how often a signal is above (or
1237 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1238 can replace MHTriggerLvl0)
1239
1240 - added ore convinient ways to set the axis-titles of your histograms
1241 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1242 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1243
1244
1245
1246 *** Version 0.8.5 (2004/08/06)
1247
1248 - new Signal Extractors: MExtractFixedWindowSpline
1249 and MExtractAmplitudeSpline
1250
1251 - implementes interleave in merpp to be able to merpp parts of a file
1252
1253 - implemented force-functionality to merpp
1254
1255 - star display to display star catalogs (MAstroCatalog)
1256
1257 - star display to 'mirror' stars to the camera (MAstroCamera)
1258
1259 - implemented a new cleaning option which allows cleaning scaled with
1260 the real ratio of the rms depending on the pixel size, not only the
1261 square root of the pixelsize (MImgCleanStd, MCameraData)
1262
1263 - removed obsolete MBlind* classes
1264
1265 - Signal extractor taking the AB flag into account implemented (this makes
1266 an odd number of slices for signal extraction possible
1267 (MExtractSignalABcorr)
1268
1269 - implemented a class extracting the pedestal from the raw-data (events)
1270 itself using empty lo-gain (MpedCalcFromLoGain)
1271
1272 - Added mean values to MPedPhotCam
1273
1274 - Added Makefile for Darwin (this OS is NOT officially supported!)
1275
1276
1277
1278 *** Version 0.8.4 (2004/04/19)
1279
1280 - new fast arrival time extractor using cubic splines:
1281 MExtractTimeFastSpline
1282
1283 - implementes multi-argument support in MDataChain
1284 ("pow(a, b)")
1285
1286 - implemented double reference support in MDataChain
1287 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1288
1289 - added support in MF for expressiond like
1290 "MHillas.fWidth<2*<MHillas.fLength"
1291
1292 - MDataChain is now able to support variables like [0], [1], ...
1293 which can be used in fit functions as parameters. The interface
1294 is implemented through the new virtual function
1295 MParContainer::SetVariables
1296
1297 - added new class MArrivalTimeCam/MArrivalTimePix:
1298 Storage containers to hold the ArrivalTime of the camera/pixel
1299
1300 - added new classes for the calibration of relative arrival times:
1301 MCalibrationRelTimePix and MCalibrationRelTimeCam
1302
1303 - added new classes to extract the signal of the blind pixel and the
1304 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1305
1306 - added new classes for the bad-pixels treatment (MBadPixels*)
1307 which are more powerfull than the old ones (MBlindPixel*)
1308 and will replace them.
1309
1310 - added filter against cosmics: MFCosmics
1311
1312 - added new class MArrivalTimeCalc2:
1313 Calculates the arrival time as the signal weighted mean of the time
1314 slices in the maximum window
1315
1316 - added a new macro call pointspreadfucntion.C that fits with a 2D
1317 gaussian the DC spot for an star. It gives you the RMS of
1318 the PSF and the center of the star, very useful for misspointing
1319 studies.
1320
1321 - added support for multi-telescope camera files. Added classes
1322 MStereoCalc and MStereoPar, classes to calculate and store shower
1323 parameters calculated from the data of two telescopes, for the MC
1324 studies regarding the MAGIC clone.
1325
1326 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1327 MC data calibrated in photons instead of ADC counts.
1328
1329 - added three macros to show the calibration and analysis chain of
1330 MC data. The macro starmc.C does both calibration and analysis, producing
1331 an output containing Hillas parameters for each event. The macro
1332 mccalibrate.C does just the calibration and writes out a file containing
1333 pixel information in photons instead of FADC data. The macro starmc2.C
1334 reads in such a file and produces an output with Hillas parameters.
1335
1336 - added MPedPhotCalc to compute pedestals in units of photons, see
1337 macro pedphotcalc.C
1338
1339 - added all class to perform the calibration, see macro calibration.C
1340
1341 - added class MFFT to perform Fast Fourier Transforms
1342
1343 - added class MSimulatedAnnealing to perform simulated annealing
1344 minimizations
1345
1346 - added new macro bootcampstandardanalysis.C which holds the skeleton
1347 of the analysis chain discussed in the december bootcamp.
1348
1349 - added support for DAQ raw data file format V2
1350
1351 - implemented an arbitrary time stamp for the events from raw-data
1352 files with file version<3. It is calculated from the run number,
1353 the date of start and the FADC clock tick from the first module
1354
1355 - implemented the correct decoding of the event time-stamp
1356 coming from the DAQ for raw-data files with file-version>2
1357
1358 - added a new classes storing the pedestals in units of photons:
1359 MPedPhotPix, MPedPhotCam
1360
1361 - added support for DC current files from the camera control
1362
1363 - added support for start- and stop-time when merpping report files
1364
1365 - added MReportCC storing the weather data from the CC-REPORT
1366
1367 - added class to fill trainings and test matrices (MTFillMatrix)
1368
1369 - added a filter performing a software trigger (MFSoftwareTrigger)
1370
1371 - Added classes to perform parts of the standard analysis (Jobs):
1372 + MJPedestals
1373 + MJCalibration
1374 + MJExtractSignal
1375 Note: All of them are preliminary!
1376
1377 - Added Iterator to iterate over files giving only the run-number
1378
1379 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1380 the evolution of a sector vs time
1381
1382
1383
1384 *** Version 0.8.3 (2003/12/05)
1385
1386 - adapted Random Forest classes to allow the use with MC
1387 multi-telescope files which can be produced with the coming
1388 camera version 0.7.
1389
1390 - added classes to read and interprete central control report files
1391 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1392
1393 - enhanced merpp (the executable) to support .raw and .rep files.
1394
1395 - added classes for light calibration (MCalibration* and
1396 MHCalibration*) by Markus Gaug. Further work has to be and will
1397 be done soon.
1398
1399 - Added a preliminary 'synchronizer' (MReadReports) which will
1400 replace MReadMarsFile as soon as it is finished.
1401
1402 - Added a tutorial macro demonstrating how report files are merpped
1403 and how they can be read from the root file in the correct order
1404 of time (readrep.C)
1405
1406 - Added a generalized histogram (similar to MH3) called MVsTime
1407 which allows to plot variables (or rules - MDataChain - of
1408 variables) vs time. For an example have a look at tempvstime.C.
1409
1410 - Changed the name of the event trees:
1411 + Events --> Events
1412 + PedEvents --> Pedestals
1413 + CalEvents --> Calibration
1414
1415 - changed name of MTime in the event trees from MRawEvtTime to MTime
1416
1417 - added displaying the sector indices to the mars event display
1418
1419 - Magic Online Analysis (MOnA) implemented in a first version
1420 (see mona.cc, MOnlineDump and MOnlineDisplay)
1421
1422 - added classes to calculate event rate
1423 (preliminary: MEventRateCalc, MEventRate)
1424
1425 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1426
1427 - added classes dealing with the telescope pointing position (MPointing*)
1428
1429 - implemented the 'final' Mars time stamp based on some experiences with
1430 the new 'Synchonizer'
1431
1432
1433
1434 *** Version 0.8.2 (2003/11/10)
1435
1436 - accelerated standard analysis by a factor of 6-8 ...
1437 + doing precalculations in MGeomCam for the pixel area ratio
1438 + creating a look up table for the single pixels in MCerPhotEvt
1439
1440 - added task to calculates weights in case you want to 'change'
1441 the energy spectrum of a monte carlo file
1442 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1443
1444 - added a new executable star which implements the
1445 star.C macro as precompiled executable. Currently a flexible
1446 setup is not possible, but a 'input card' setup will follow.
1447
1448 - Starting to implement Multi-Telescope-Support based on the
1449 upcomming camera version 0.7. The base for a general support
1450 is implemented and the star-functionality is proven to work.
1451
1452 - Replaced Event-Display in and Camera-Display in the Mars GUI
1453 executable by a more convinient display base on MStatusDisplay.
1454
1455 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1456
1457
1458
1459 *** Version 0.8.1 (2003/10/20)
1460
1461 - added signal subtraction for pure on data by means of fitting
1462 the background in the off region or by performing a combined
1463 signal/background fit. Provides necessary histograms for
1464 obtaining energy spectra and a light curve.
1465
1466 - added classes to perform and study the selection of the
1467 2nd Level Trigger on MC data (example in triglvl2.C macro)
1468
1469 - added pedestal calculation
1470
1471 - implemented "democratic cleaning" (tail cut value proportional
1472 to pixel area) according to Wolfgang's suggestion.
1473
1474 - added Sigmabar treatment (calculation and basic histogramming)
1475
1476 - added basic routines to apply padding
1477
1478 - added first implementation of MARS-based source visibility plotter
1479 (needs to be linked against slalib, preliminary version)
1480
1481 - enhanced functionality of data chains: random numbers, conversion
1482 functions and access to MHMatrix objects
1483
1484 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1485 numbers under certain circumstances (runs with 0 events included)
1486
1487 - fixed a bug in the general filter MF (didn't work on some systems
1488 at all)
1489
1490 - fixed a bug in chaining files, which caused the analysis to crash or
1491 ignore files
1492
1493 - implemented more geometry classes describing the parameters used
1494 to simulate the PMT camera
1495
1496 - added new Monte Carlo classes containing the setup of the different
1497 programs in the MC chain.
1498
1499 - added a (preliminary) general task to evaluate chi-square of a given
1500 parameter in an eventloop.
1501
1502 - first implementation of a container describing the observatory
1503 location (Long, Lat, etc)
1504
1505 - added Random Forest - method for g/h-separation
1506
1507 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1508 (this means, that it is compiling, but not yet fully tested)
1509
1510 - added a new status display which can show the present status
1511 of histograms while an eventloop is running (MStatusDisplay,
1512 an example can be found at status.C)
1513
1514 - reorganized directories:
1515 classes describing the image --> mimage
1516 classes containing Monte Carlo Histograms --> mhistmc
1517 classes for Random Forest method --> mranforest
1518
1519 - added (event-)weights to fill histograms
1520
1521 - colors in logging output to screen
1522
1523 - changes to the Image Parameter declaration:
1524 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1525 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1526 + MHillasExt now derives from MParContainer instead of MHillas
1527 --> Files written with the old definition are more or less unreadable
1528
1529 - reading of reflector files
1530
1531 - display data from reflector files in the camera
1532
1533 - implemented currents (and display them in the camera)
1534
1535 - logarithmic scale in camera
1536
1537 - added class to iterate through directory contents (MDirIter)
1538
1539
1540
1541 *** Version 0.8 (2002/11/18)
1542
1543 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1544
1545 - corrected 48(!) wrong entries in the Next Neighbor table of the
1546 Magic Camera (all in the inner part of the outer ring, mostly
1547 missing a single NN)
1548
1549 - Fixed a bug in the table describing the Next Neighbours of the
1550 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1551 have any neighbour)
1552
1553 - changed trigrate.C: now it calculates the pure NSB triggers from
1554 a camera file (generated with no showers), so there is no need
1555 to introduce them by hand in the BgR array (for more details
1556 please ask Abelardo)
1557
1558 - added MHHadronness (and MHadronness) as a general facility to evaluate
1559 the quality of a gamma-hadron seperation method
1560
1561 - changed MWriteAsciiFile to accept rules (MDataChain)
1562
1563 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1564 must be replaced by calles to MWriteAsciiFile::AddColumn and
1565 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1566 changed.
1567
1568 - Implemented generalized event-matrices (one row per event)
1569 (MHMatrix)
1570
1571 - implemented the one dimensional composite probabilities
1572 (MHCompProb, MCompProbCalc, comprob.C)
1573
1574 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1575 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1576
1577 - Added a camera display displaying the pixel numbers to the
1578 event display gui.
1579
1580 - Added Monte Carlo Informations to event display gui
1581
1582 - Changed the camera display to display the pixel numbering
1583
1584 - Added three buttons to the camera display to change the palette
1585
1586 - Added the number of used and core pixels after image cleaning
1587 to MHillas
1588
1589 - Changed the algorithm used in MHillas according to TDAS 02-03
1590
1591 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1592
1593 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1594
1595 - Added fCosDeltaAlpha to MHillasSrc
1596
1597 - The numbers of photons used to calculate fConc and fConc1 in
1598 MHillasExt are now scaled with the pixel size, so that one get
1599 a four times smaller value for the bigger pixels in the outer ring.
1600
1601 - added new task to smooth the camera contents (MCameraSmooth)
1602
1603 - added possibility to use interpolated pixel values for blind pixels
1604 instead of removing it completely from the analysis
1605
1606 - Implemented the possibility to save the whole eventloop with
1607 its setup to a file. This information can be read and from
1608 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1609 and MEvtLoop::MakeMacro. If you find something not working, please
1610 report - this stuff is still in a beta phase.
1611
1612 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1613 file having crab starfield, but also for all following files - fixed
1614
1615 - MTaskList::PrintStatistics can now be instructud to print also the
1616 title, too: use PrintStatistics(0, kTRUE)
1617
1618 - Changed the image cleaning so that pixels with to many 'used'
1619 neighbors are left used (to get rid of 'holes' in events)
1620
1621 - Introduced more output to the camera displays
1622
1623 - Added an array of histograms (eg one hist per run), MHArray
1624
1625 - Added a _preliminary_ version of the reader for CT1 PreProc files
1626 (MCT1ReadPreProc)
1627
1628 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1629 (thanks to Raquel)
1630
1631 - added the first energy estimator (MEnergyEstParam, estimate.C,
1632 estfit.C) using a parametrization
1633
1634 - Added some new Monte Carlo paremeter containers used to store
1635 setup information from the MC chain (MMcConfigRunHeader,
1636 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1637
1638
1639
1640 *** Version 0.7 (2002/04/30)
1641
1642 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1643 the pedestal mean value was saved incorrectly. For files from
1644 this versions we substract 0.5 from the pedestal mean.
1645 WARNING: This may effect your results, so don't wonder...
1646
1647 - First implementation of an algorithm using only triggered events
1648 for the collection area calculation
1649
1650 - Ascii Output can now also be used for parameter containers which
1651 doesn't overload MParCointainer::AsciiWrite
1652
1653 - The Ascii Output is now also capable of writing single data members
1654 of one container
1655
1656 - You are now able to change the order of the values written to the
1657 ascii file
1658
1659 - You can now specify a conversion factor for each data member written
1660 to an ascii file. This may be usefull to change the units of the
1661 data member (eg. degrees instead of millimeters in case of the
1662 hillas parameters)
1663
1664 - Replaced old MHillas by a new structure which allows you to extend
1665 the parameters stored in MHillas very easily:
1666 see MHillas and MHillasExt
1667
1668 - Added classes to handle source dependancy of image parameters:
1669 see MHillasSrc
1670
1671 - Added container (MBinning) to have a standard input for the binning
1672 in different histograms (eg. the Energy bins should be the same in
1673 all histograms)
1674
1675 - Changed Hillas histograms from mm to deg
1676
1677 - Added the flexible binning to the hillas histograms
1678
1679 - Added a filter for the alpha parameter (MFAlpha)
1680
1681 - It is now possible to write single data members of a class object to
1682 an output stream instead of the whole container only
1683
1684 - Added a generalized filter for a data member:
1685 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1686
1687 - Added a generalized Filter parser for more difficult filter rules
1688 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1689
1690 - Added new Monte Carlo histograms:
1691 MHMcEnergyImpact and MHMcEfficiency
1692
1693 - Added many new histograms needed for the flux calculation.
1694
1695 - Added a generalized histograms which can fill and show up to three
1696 data members in either a one-, two- or three-dimensional histogram, eg:
1697 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1698
1699 - Added:
1700 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1701 * calculation of <Theta> as a function of time (MHThetabarTime)
1702 they are needed in the flux calculation in
1703 order to select for a given bin in Theta (or time) the appropriate
1704 effective collection area, which is assumed to be given as a function
1705 of Theta and the true energy
1706
1707 - Added calculation of the migration matrix in the energy
1708 (MHMcEnergyMigration):
1709 the migration matrix describes the migration from the true (E_true)
1710 to the estimated energy (E_est); it is needed to determine the
1711 distribution of E_true from the measured distribution of E_est
1712 by unfolding
1713
1714 - changed the color palette in the camera display to DeapSea.
1715
1716
1717
1718 *** Version 0.6 (2002/01/15)
1719
1720 - Introduce the option of disable pixels (MBlindPixels and
1721 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1722 able to deal with Star Field NSB.
1723
1724 - Fixed a bug in the pedestals substraction
1725
1726 - Introduced verbosity levels
1727
1728 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1729
1730 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1731 work correctly (thanks to Abelardo)
1732
1733 - Introduced correct treatment of the diffuse Night Sky Background
1734 and NSB (MMcPedestalNSB)
1735
1736 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1737
1738 - Introduced MMcRunHeaders which contains monte carlo run informations
1739
1740 - Added a 'Print'-Task (MPrint) which calls the Print function
1741 of a parameter container for each event
1742
1743 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1744
1745 - changes to be more efficient with root 3.02/06
1746
1747 - root 3.02/06 fixes:
1748 + the memory leak when reading MRawEvtData
1749 + loosing more time than necessary to update the progress bar
1750
1751 - MWriteAsciiFile is now capable of writing more than one container
1752 in a line. For example: To be able to write Monte Carlo and
1753 Hillas values (energy and alpha) in one line.
1754
1755
1756
1757 *** Version 0.5 (2001/11/06)
1758
1759 - Added new GUI functionality (Analysis)
1760
1761 - Added a camera display to be able to display events in the camera
1762 together with the calculated hillas ellipse
1763
1764 - Added a 'Clone'-Task (MClone) which can clone a parameter container
1765 object at any state of the analysis, so that the output are several
1766 states
1767
1768 - Fixed a bug in the collection area error calculation
1769 (Thanks to Ciro and Abelardo)
1770
1771 - Fixed a bug which causes merpp to crash in some environments
1772
1773 - Implemented auto enabling scheme for Branches to speed up reading
1774 a lot (see MReadTree and MTask)
1775
1776 - Fixed a bug in the Histogram classes which caused histograms to
1777 be written to a file by MWriteRootFile without request
1778
1779 - changed the object I/O from the old stylish root I/O to the new
1780 'auto evolution scheme' This was done only for classes which are not
1781 yet used in Monte Carlo files, so that these files are still readable.
1782
1783 - Added support for a progress bar in MEvtLoop and MReadTree
1784 (see the Analysis Window in Mars for an example)
1785
1786 - Fixed a bug in the package creation which disturbed the conversion
1787 between a mars version unpacked from a tar file and the repository.
1788
1789 - Changed the code to writer merpped (converted into root format)
1790 raw files, to get faster (around 10%)
1791
1792
1793
1794 *** Version 0.4 (2001/09/20)
1795
1796 - This release is made to compile on a root version >= 3.00
1797
1798 - Fixed a bug which causes MReadTree to read the first file only
1799
1800 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
1801
1802 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
1803
1804 - Added a task to write several container to a root file (MWriteRootFile)
1805
1806 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
1807
1808 - Added calculation of the collection area (MMcCollectionAreaCalc)
1809
1810 - fixed some bugs in the Hillas calculation
1811
1812 - added filters to be able to control the task execution dependent on
1813 a parameter (for example: the number of level 1 triggers in a MC-file)
1814
1815
1816
1817 *** Version 0.3 (2001/04/23)
1818
1819 - Many demo macros added
1820
1821 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
1822
1823 - Hillas Calculation added
1824
1825 - Standard image cleaning available
1826
1827 - MReadTree is now able to handle more than one file
1828 (Remark: of the same structure)
1829
1830 - Now we are able to display events in a first version of the
1831 Camera event display. To do this we must run the macro
1832 "macros/readCT1.C" to read data from CT1.
1833
1834
1835
1836 *** Version 0.2 (2001/01/24)
1837
1838 - First Implementation of a Gui to read the raw data. Start the
1839 gui with the command mars.
1840
1841
1842
1843 *** Version 0.1 (2000/12/20)
1844
1845 - First official release 0.1
1846
1847 - Changes:
1848
1849 + changed calling style of MRawPixelIterator from do...while to
1850 while-loop
Note: See TracBrowser for help on using the repository browser.