source: trunk/MagicSoft/Mars/NEWS@ 8056

Last change on this file since 8056 was 8056, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 77.5 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5
6
7 *** Version 0.10.1 (2006/10/11)
8
9 - general: HTML logging output was distorted... fixed.
10
11 - general: Changed the writing of the sequencefiles such that only
12 as many pedestal files as giving at least 1000 pedestal events which
13 are nearby the first calibration run are used as pedestal runs
14
15 - sponde: In the calculation of the collection area(s) and the
16 distribution for MOnte Carlo and estimated energy the error
17 calculation was wrong because root didn't take the errors
18 properly into account... fixed.
19
20
21
22 *** Version 0.10 (2006/10/10)
23
24 - general: all executables now check consistency of the root version
25 installed with the root version used for compilation. The return
26 code in this case is 255.
27
28 - general: The algorithm to build seqeunces has been redesigned
29 completly. It is now more flexible in terms of a resource file
30 resources/sequences.rc which can be used to partly overwrite
31 the default algorithm and defined the important part of the
32 algorithm. It also takes correctly into account several ways
33 of taking wobble-data. Currently the new algorithm doesn't take
34 the number of pedestal events anymore into account (so a sequence
35 could have much less than 1000 pedestal events and data runs are
36 no-more used instead)
37
38 - general: a lot of small changes to make the code compatible with
39 root 5.12/00 and gcc 4.1
40
41 - general: Fixed some warnings thrown if more warnings are switched
42 on in the compiler
43
44 - general: Added a function to MMath which returns the Median of
45 the distribution abs(y[i]-median) but at 68:32 division instead
46 of 50:50, which is somehow the median counterpart of the rms.
47
48 - general: MAstroCatalog allows now to read calatog files (as bsc5)
49 even if they are compressed with gzip (recommended compression
50 is with "-1")
51
52 - showplot:
53 + batch mode creation of image files now works with root 5.12/00
54 + added support for writing bmp (though it never produces
55 bmp which can be read by programs like xv or gimp)
56 + added support for xml
57 + added new option to start the display with a different size, by
58 --display-width=nnn or --display-height=nnn
59 + added options to define the canvas size when the display is started
60 --canvas-width=nnn or --canvas-height=nnn
61 the option can also be used for batch-mode conversion
62 + added an option which automatically fits the display size to the
63 desktop-size: --auto-size
64
65 - merpp: didn't recognize files with the extension .raw.gz - fixed.
66
67 - merpp: allow the reports to have 1000ms due to a bug in the camera
68 program.
69
70 - callisto: New swapped pixels have been found and corrected. For
71 details see MRawRunHeader::FixAssignment()
72
73 - callisto: Callisto now raises an error if one of the input files could
74 not be opened.
75
76 - callisto: In some rare cases it could happen that in the hi-gain
77 extraction of the digital filter the extractor returned nonsense
78 results due a wrong initializion of a variable
79
80 - callisto: The lo-gains have been marked as valid in some cases
81 when they got not extracted at all (deltsumlo=deltatimelo=0) because
82 the allowed extraction range (fLoGainLast-fLoGainFirst) was
83 smaller than the number of slices (fLoGainWindowSize) needed
84 by the lo-gain extractor
85
86 - callisto: Updated absolute calibration constants (muon calibration)
87
88 - callisto: fixed a bug which caused the hi-gain saturation not
89 to be handled properly
90
91 - callisto: fixed a bug which gave weird results if hi- _and_
92 lo-gain could not be extracted properly
93
94 - callisto: improves handling of extracted signal if lo- and/or
95 hi-gain could not be extracted properly. If no appropriate
96 calibration of either the signal or the arrival time is possible
97 the pixel is now markes as unsuitable instead of estimated.
98
99 - callisto: Fixed a problem in the spline extraction which gave
100 weird results if the signal was extracted from the first (and
101 highest) slice
102
103 - callisto: Fixed a bug regarding the use of the QE which doesn't
104 effect the result because the default is used anyhow.
105 (The bug was there since 14/07/2005)
106
107 - callisto: Changed the default for fgLoGainStartShift
108
109 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
110 factors to be always 10 for all pixels as soon as the first
111 calibration update has happend.
112
113 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
114 was off by more than one slice (which gives wrong values for
115 pixels which have saturated the hi-gain) This was a problem
116 mainly for timing studies, not so much for the automatic standard
117 analysis. Also the values for the Spline have been changed slightly:
118 + Digital Filter from 1.70 to 0.95
119 + Spline from 1.39 to 1.30
120 The numbers were sorted out by an extensive test in the
121 test-database.
122
123 - callisto: Removed the tab showing the average calibrated arrival
124 time. It never gave useful information.
125
126 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
127 lo-gain pulse for data pulses if hi- and lo-gain have saturated
128 and both were extracted because the hi-gain was above the
129 LoGainSwitch.
130
131 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
132 lo-gain pulse position (after application of LoGainOffset, which
133 means in the ideal case it is 0) for data pulses if hi- and lo-gain
134 have saturated and both were extracted because the hi-gain was above
135 the LoGainSwitch.
136
137 - callisto: After extensive tests a new threshold level for determination
138 of the pulse position has been found at 50phe. This is due to the
139 fact that for lower pulses the arrival time changes its average
140 behaviour dramatically. It tends to the average of the extraction
141 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
142
143 - callisto: Added two more plots to the calibration part. The average
144 extracted signal and the average extracted arrival time as
145 extracted by the signal extractor (This can help debugging problems
146 because it doesn't involve a fit)
147
148 - star: changed the fit for the effective on time such that initial
149 values are calculated automatically now instead of using build
150 in values. This makes the fit more indepedant of the underlaying
151 rates. With a test of ~350 sequences in the test database it could
152 be shown that the new fit gives the same result +/-1sek.
153 The highest deviation was +5s the lowest -10s. You can now control
154 the bahaviour with two resource values:
155 MHEffectiveOnTime.FistBin: 3
156 MHEffectiveOnTime.NumEvents: 12000
157 Use FirstBin=1 and NumEvents=120 to fit the effective on time
158 from the resulting gamma candidates
159
160 - star: The Center histogram in MHHillas is now by default displayed
161 with the colz draw-option
162
163 - ganymed: now produces valid error codes if failed
164
165 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
166 with the option "hadronness" instead of "area" or "both" if
167 you want to use both cuts. The hadronness cut includes a fixed
168 cut in hadronness (index 8) and a fixed cut in size (index 9).
169
170 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
171 the M3Long of the anti source to be not properly evaluated
172 (actually is was evaluated as a unique random number) in case
173 of optimization with anti-theta cut switched on. This might have
174 lead to improper, but not necessarily wrong, optimization results.
175
176 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
177 how to use random forest
178
179 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
180 ganymed_onoff.rc. Seems to be unintentional that they were different.
181
182 - sponde: Since the introduction of the possibility to define a
183 normalization energy instead of using the integral the default
184 was not using the integral anymore but a normalization energy of
185 1GeV. It is now the integral again.
186
187 - sponde: Fixed a problem in the weighting which did not allow
188 a MC slope of -1.
189
190
191
192 *** Version 0.9.6 (2006/05/24)
193
194 - general: changed the binning of the azimuthal profile of the camera
195 such that it is aligned with the 60deg boundaries.
196
197 - merpp: better handling of problems with the TH, TD part of the
198 CC-REPORT for files older than 200507190 and 200412210
199 respectively
200
201 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
202
203 - merpp: implementd latest changes in starguider reports (sinc 9th May)
204
205 - callisto: if an arrival time is extracted outside the fadc range is
206 was set to the boundary before. Now a random number is assigned
207 instead to avoid unfortunate coincidences of arrival times just
208 by this arbitrary value.
209
210 - callisto: added a new option to callisto.rc which allows
211 to set the maximum arrival time difference allowed for the
212 badpixel algorithm to determin whether a pixels belongs to a shower:
213 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
214
215 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
216 to 0.9 as suggested by Stefan due to a recent study on the fraction
217 of pixels surviving the image cleaning
218
219 - callisto: switched off error in case of "pulse is too much to the left"
220
221 - callisto: The extraction window is not adapted anymore. This means that
222 the pulse is extracted from the full range. The draw-back is that the
223 background (pedestal) will become slightly higher. Switching on/off
224 the PulsePosCheck in the callisto.rc only effects filling the
225 histograms.
226 WARNING: If the pulse is too much to the left data is calibrated!
227 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
228 in the database to make sure that your data is valid!
229
230 - star: Show also the number of stars correlated correctly by the
231 starguider
232
233 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
234 than one off-source region in wobble-mode. To use it add the following to
235 your ganymed_wobble.rc:
236 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
237 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
238 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
239 + Cut1.ThetaCut: None
240 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
241
242 - ganymed: in the case the latest report is older than a default (currently
243 one minute) and the current report will be skip the starguider
244 correction and calibration will be reset. The maximum age can be
245 setup from ganymed.rc by (minutes):
246 MPointingDevCalc.MaxAge: 1.5
247
248 - ganymed: A first implementation showing all size-bins for the theta-sq
249 resp. alpha-plots in a single tab automatically
250
251
252
253 *** Version 0.9.5.1 (2006/05/05)
254
255 - general: Added a new option "zdiff" to the Makefile which runs
256 "cvs diff" as "make diff" would do, but with compression
257
258 - general: accelerated MTFillMatrix (used for eample in all training
259 and optimization macros) by skipping some obsolete calles in the
260 eventloop the first and second loop could be accelerated by ~20%
261
262 - general: Added a missing feature in the MFilterList class which
263 prevented MFEnergySlope from working correctly in trainenergy.C
264
265 - general: Accelerated the random forest training and usage a bit
266
267 - merpp: Adapted to new raw data file format version 6
268
269 - merpp: fixed a problem with reading the starguider reports
270 after 6.3.2006
271
272 - callisto: At some times six pixels had to be exchanged manually in the
273 data. If the pixels to be swaped are both not found, an error was raised
274 and calibration was stopped. Now it is assumed they are intentially not
275 mapped and the Error has been changed to a Warning.
276
277 - star: Added new image cleaning based on the arrival time of the shower.
278 The new cleaning can be accessed using the parameter "Time" instead of
279 the the old one (like "Absolute) in the star.rc-file.
280 Recommended parameters:
281 + MImgCleanStd.CleanLevel1: 8.2
282 + MImgCleanStd.CleanLevel2: 5
283 + MImgCleanStd.CleanRings: 2
284 + MImgCleanStd.KeepSinglePixels: No
285
286 - star: Simplified the calculation of the effective on time. By letting
287 the fit start in the third bin the result should become more stable.
288 The fit quality is now ignored for the theta-plot which is not used
289 in the analysis later. Still better pre-cut which, for example,
290 remove events triggered by car-light (rate changing on a short
291 time-scale) are missing.
292
293 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
294 for optimization (kWeakSource) which is suggested by the Berlin
295 people for weak sources.
296
297 - macros: plotdb.C:
298 + if no dataset and no time-interval is given only sequences with
299 an effective on-time above five minutes are plotted anymore
300 + added a new tab "RelTime" displaying the relative on-time
301 (effective on-time divided by the observation time)
302
303 - macros: optim*.C: by skipping some obsolete calles in the eventloop
304 the optimization became a lot faster
305
306 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
307 To display them just delete the pads displayed on top.
308
309 - ganymed: fixed a bug which could cause strange behaviour in wobble
310 mode if no starguider information was available due to an incorrect
311 initialization of the starguider calibration
312
313 - ganymed: The scale region in the False Source Plot (MHDisp) can now
314 be changed from within the plot. It can also be setup from the
315 resource file using:
316 + MHDisp.fScaleMin: 0.325
317 + MHDisp.fScaleMax: 0.475
318
319 - ganymed, showplot: Fixed a problem with the fit to the off-data
320 (HistOff) which could cause a time lag or an inifinite loop.
321 The bug did not effect the results at all.
322
323 - sponde: Added a new tab showing the effective collection area after
324 trigger (including the software trigger)
325
326 - sponde: MMcSpectrumWeight has a new option which allows to define
327 the scaling factor not by the integral of the events but at
328 a defined energy:
329 e.g. MMcSpectrumWeight.NormEnergy: 200
330
331 - MTFillMatrix, sponde: by skipping some obsolete calles in the
332 eventloops the loop could be accelerated by ~20%
333
334
335
336 *** Version 0.9.5 (2006/03/13)
337
338 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
339 and added the standard Disp-parametrization
340
341 - macros: added a new macro datacenter/macros/plotstat.C allowing
342 to plot statistics about the data processing
343
344 - macros: added a new macro to plot the muon correction coefficients
345 versus period (macros/plot/mucal.C)
346
347 - showplot: path inflation for ganymed files was broken
348
349 - callisto: Fixed an important bug. When the number of saturating pixels
350 were calculated the bad pixel information already available from the
351 calibration was ignored. This yields wrong values in case pixels
352 are broken and saturate all the time or randomly.
353
354 - callisto: Updated Muon calibration constants. Spline data now also uses
355 different values for different periods
356
357 - star: The time-evolution shown in the effective on-time plot now displays
358 the axis range (if there are no holes it should be similar to the
359 effective on-time)
360
361 - star: Added two new image parameters:
362 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
363 the three pixels next to the center of gravity and the size
364 + MNewImagePar.fConcCore: The ratio of the signals of all
365 pixels inside or touching the ellipse and the size
366
367 - ganymed: now stops in requested source isn't found in catalog file
368
369 - ganymed: Many improvements to the phi-plot in wobble mode:
370 + with a template the ideal background is displayed
371 + a possible camera inhomogeneity is taken into account
372 + the anti theta cut is better supported
373 + the phi cut is automatically calculated from the theta cut
374 See the examples in ganymed_wobble.rc for more details.
375
376 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
377 times the bin-width instead of the absolute energy
378
379 - ganymed: New cuts for on/off and wobble mode
380
381 - ganymed: The smearing of the False Source plot has been increased
382 to 0.06
383
384 - ganymed: The starguider calibration can now be changed from the
385 resource file.
386 See the examples in ganymed*.rc for more details.
387
388 - ganymed: added a new option for on-/off-observations
389 MJCut.RandomSourcePosition
390 If switched on the distribution of observation time of the source
391 position in the camera is calculated from the on-data and randomly
392 applied with this distrbution to the off-data.
393
394 - ganymed: by skipping some obsolete calles in the eventloop the
395 first and second loop could be accelerated by ~20%
396
397 - ganymed: The default in ganymed_onoff.rc is now to determin the source
398 position in the off-data randomly according to its distribution in the
399 on-data.
400
401
402
403 *** Version 0.9.4.3 (2006/02/13)
404
405 - general: Fixed a bug in most of the programs which prevented the
406 compile date in the startup message to be displayed
407
408 - general: Simplified program calls. The following abbreviations
409 are now possible:
410 showlog callisto 55599
411 showplot signal 55599
412 star 55599
413 callisto 55999
414 ganymed 2
415 In this cases the corrsponding root-, log-, sequence- or dataset-
416 filename is automatically compiled using the default datacenter
417 paths ("/magic/*")
418
419 - general: Fixed a long outstanding bug which made axis tick marks
420 disappear if MDataFormula was used (eg. abs(x))
421
422 - general: Updated MMath with new functions to calculate the results of
423 a exponential, logarithmic and powerlaw fits analytically.
424
425 - general: Updated some macros with comments:
426 + macros/optim/optimdisp.C
427 + macros/optim/optimenergy.C
428 + macros/optim/optimwobble.C:
429
430 - general: MTFillMatrix (the class to fill one or two MHMatrix from
431 files) now allows adding a pre-cut like in the optimization. E.g. this
432 is useful to perform g/h-separation cuts before training the random
433 forest.
434
435 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
436 correctly assigned in the raw data assignement table. A fix to correct
437 the assignment tabel have been implemented.
438
439 - general: MAstroCatalog now allows rotating of the sky-grid and stars
440 by 90, 180 and 270 deg.
441
442 - general: the macro plotdb.C now allows to highlight sequences belonging
443 to a datset. For more details see the descritions in the macro.
444
445 - StatusDisplay: Fixed the algorithm to calculate the size ratio
446 of the display, it gave wrong results espacially for big sizes.
447 Now the embedded canvas should always have a ratio width/height=3/2.
448 The "Size" options have been updated with values fitting the 3/2
449 size ratio.
450
451 - RanForest:
452 + Updated the random forest classes to support also the
453 regression method implemented by Thomas H.
454 + added new tutorial macro how to train the random forest
455 for energy estimation (macros/optim/rfenergyest.C)
456 + new classes to train the random forest (still in development)
457 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
458 + new tutorial macros for random forest training in macros/train
459 trainenergy.C, traindisp.C, trainseparation.C
460
461 - mars: now allows to setup a cut in the resource file mars.rc to choose
462 the events to be displayed, eg:
463 Cut.Condition: {0} && {1}
464 Cut.0: MHillas.fSize>100
465 Cut.1: MHillas.fSize<900
466
467 - merpp: Made aware of the new .rep format 200510250. This includes
468 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
469 the discriminator thresholds (MCameraTD) and the disciminator
470 delays (MCameraTD). All of them come with the CC report and are therefor
471 written to the CC tree.
472
473 - callisto: fixed a bug in the calculation of the arrival times in
474 the Digital Filter. They were all shifted by the same amount
475 fHiGainFirst. This caused an offset in the order of the position of
476 the left border of the extraction window in the times calculated
477 from high-gain and from low-gain. The bug effected only the absolute
478 arrival times. The bug was there since 30.1.2005.
479
480 - callisto: Changed the ExtractionWindow for the pulse position check
481 such that the camera inhomogeneity becomes as less as possible and
482 comparable to the pulso position check switched off. More details
483 on the study will be given at our result web-page.
484
485 - ganymed: ganymed.rc, ganymed_onoff.rc:
486 changed to new cuts trained with 1ES1218 and Crab-data
487 for maximum sigma*log10(excess)
488
489 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
490 a new option was implemented to estimate Disp (CalcDisp)
491
492 - ganymed: Implemented two new options which allow
493 to overwrite the default path to search for the sequence files
494 --ins=/magic/sequences
495 and where to search for the image data
496 --ind=/magic/data/star
497
498 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
499 dx/dy from the resource file by
500 MSrcPosCorrect.Dx
501 MSrcPosCorrect.Dy
502
503 - ganymed: fixed reading the source catalog. Only as many chars
504 as the requested source name had were compared (If a source
505 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
506 were requested it could happen that the coordinates of
507 "1ES1218" were read) The source coordinates are now printed
508 in addition to its name to the logging output.
509
510 - ganymed: changed the background fit in the case of a ThetaSq function
511 from a polynomial to a exponential, this should give a big improvement
512 for on-only analysis'
513
514 - ganymed/sponde: Calculation of the error of single size-/energy-
515 bins now uses Li/Ma (5) instead of LiMa (17)
516
517 - sponde: Added a plot E^2*dN/dE
518
519 - sponde: The energy estimator plot should now show values like
520 they are commonly used.
521
522 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
523 (a powerlaw with cutoff didn't work before)
524
525
526
527 *** Version 0.9.4.2 (2005/10/01)
528
529 - general: added new tutorial macro macros/tutorials/threshold.C:
530 how to calculate the threshold
531
532 - general: added a new game. Start it from the interpreter with
533 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
534 and MagicReversi)
535
536 - general: neighbor pixels in MGeoms are now sorted clockwise
537
538 - merpp: made aware of new format 20050829-0
539
540 - callisto: New scale factors from muon analysis, stored in new
541 resource file resources/calibration.rc
542
543 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
544 the eventloop if something went wrong. This is necessary for the
545 automatic processing
546
547 - callisto: Implemented a new treatment for the time information
548 developed by S.Ruegamer, this should give much better response than
549 the old very primitive algorithm. This is especially important
550 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
551 treatment was buggy! As neighbor pixels to interpolate the
552 arrival times always the pixels 0 to 5 were taken)
553
554 - callisto: In addition to the new treatment of arrival times the
555 decision of the treatment whether a pixel contains shower
556 information or not is used to improve the signal interpolation
557 further. Previously interpolated pixels showed a non-zero signal
558 do the peak searching signal extractors. Having a signal pixel
559 beside raised the signal above the cleaning level. Thus the
560 pixel survived cleaning to often but with a too low mean signal.
561 By replacing empty pixels with a gaus (mean and rms from the
562 corresponding Area entries in MPedPhotCam) this effect can
563 be supressed.
564
565 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
566 got lost when the events were stored by the calibration... fixed.
567 (This was no problem for normal image cleaning because the pixel
568 content was artificially set to 0 not surviving standard cleaning
569 algorithm)
570
571 - callisto: Fixed a bug which caused the random and peak-search pedestal
572 extracted with an extractor to be exchanged for the first (roughly)
573 500 events (*Extractor and *ExtractorRndm).
574 (They were simply exchanged in callisto.cc) This bug might have been
575 introduced in Mars 0.9.4 when the order of calculation of the two
576 types of pedestal in callisto got exchanged. The bug only effects
577 the first seconds of data of each sequence.
578
579 - star: Taking the arrival time of Muons into account the calculation
580 of the parameters could be made independant of the noise
581 (pedestal rms). The dependance was due to the bias of the peak search
582 extractor. Now only a ZA dependamcy is left which is not yet fully
583 understood.
584
585 - ganymed: The sequences were still not sorted correctly in any case,
586 because they were sorted by the full qualified path name. Now they
587 are sorted by their sequence number.
588
589 - ganymed: new values for the spark-event-cut
590
591 - sponde: required missing MEnergyEst from ganymed.root... fixed.
592
593
594
595 *** Version 0.9.4.1 (2005/08/18)
596
597 - callisto: fixed some problems with the calibration in case of
598 inteleaved events. Therefor the final and some intermediate
599 fits are skipped which would take place on partly filled #
600 histograms and gave wrong results or failed completely.
601
602 - callisto: If the intermediate finalization of the histograms
603 calculating the mean charge of the calibration signal fails
604 it is counted now and printed in PostProcess of MCalibCalcFromPast.
605
606 - ganymed: Fixed some bugs which caused problems in On-only mode.
607 Still the false source plot doesn't give reasonable results.
608
609
610
611 *** Version 0.9.4 (2005/08/05)
612
613 - general: Fixed the ZA binning. It did not correctly fit the
614 MC binning
615
616 - general: Added a class to correct for the missfocussing in
617 April (MSrcPosCorrect)
618
619 - general: Random Forest energy estimator should now work properly
620
621 - general: MHCamera now displays the profiles in deg instead of mm
622
623 - general: MH::SetPalette offers a lot of new palettes
624
625 - general: MHillas - the case of CorrXY==0 is now handled properly
626
627 - general: implemented the possibility to change the line and
628 marker style of a sky-grid drawn by MAstroCatalog
629
630 - general: Runs in sequences and datasets are now automatically
631 ordered (it is assumed that the order of their filenames correctly
632 represents the order of observations) to ensure correct reading
633 of the subsystem data
634
635 - general: Runs cannot be added to a sequence twice anymore. Also
636 Sequences cannot be added twice anymore to a dataset.
637
638 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
639 It gave wrong results by 1./2pi
640
641 - showplot: got a new option to start a root interpreter, too
642
643 - mars: now displays a rough estimate of Disp and the third moment
644
645 - mars: now displays the event time MTime if available
646
647 - mars: show muon parameters graphically
648
649 - mars: now the file to open can be given as commandline
650 argument
651
652 - merpp: Added support for new arehucas version >= 200507190
653 implementing values for three temperature sensors in the
654 counting house (MCameraAUX) and the name of the HV settings file
655 (MCameraHV).
656
657 - merrp: Also fixed some problems with wrong versions numbers stated
658 by arehucas and implemented some fixed for old versions (<200407070)
659
660 - callisto: MCalibrationHiLoCam can now be printed from its context
661 menu, eg in the TBrowser
662
663 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
664 - 1.39 (MExtractTimeAndChargeSpline)
665 - 1.40 (MExtractTimeAndChargeDigitalFilter)
666 This is important mainly for timing studies.
667
668 - callisto: Changed limits in MHCalibrationChargeCalc from
669 - -100.125 to -98 (fgChargeHiGainFirst)
670 - 1899.875 to 1902. (fgChargeHiGainLast)
671 - -100.25 to -99 (fgChargeLoGainFirst)
672 - 899.75 to 901. (fgChargeLoGainLast)
673 Introduced new limits:
674 - fgNumLoGainBlackoutLimit: 0.05
675 - fgLoGainBlackoutLimit: 3.5
676 - fgLoGainPickupLimit: 3.5
677
678 - callisto: The handling of automatic weights for the digital filter
679 has been improved. There are now new calibration weights special
680 for Monte Carlo calibrations.
681
682 - callisto: Updated Muon scale with latest results (1% difference
683 for most data, 5% for Mar/Apr'05)
684
685 - callisto: use a new criterium to exclude bad pixels: If the high-gain
686 was saturated and the blackout-events in the low-gain exceed the
687 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
688 This excludes those pixels which have a saturating high-gain
689 channel, but the low-gain switch does not switch often enough
690 to make the distribution reliable.
691
692 - callisto: fix a bug counting the number of saturated events. Up to now,
693 the number of saturated slices was counted (which is one for a not too
694 high number), but for some (pathological) pixels, many more slices
695 saturated and produced wrong limits.
696
697 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
698 + MCalibrationRelTimeCam.CheckFitResults: Yes
699 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
700 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
701 + MCalibrationRelTimeCam.CheckOscillations: Yes
702
703 - callisto: introduce max. number of events for intercalibration,
704 the rest gets skipped. Default: 4096
705 The calibration causes too many un-reliable pixels if more
706 than about 5000 events are treated (@500 Hz) because of the
707 mode hopping of the VCSels. However, in the past, some
708 calibration runs have been taken (erroneously) with more
709 than 5000 events, especially the intensity scans where
710 a good precision is needed.
711
712 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
713 photo-electrons for the spline extractor by 1-2% (correctly).
714
715 - callisto: The intercalibration is now done using a full f-factor
716 method instead of a simple update. This makes things slower but
717 more reliable in terms of gain-fluctuations and sudden VCSEL gain
718 changes.
719
720 - callisto: MPedestalY3 now uses the same extraction range as the data
721 as calculated by MPedestalY2
722
723 - callisto: A check of the fraction of allowed unsuitable (10%) and
724 unreliable (30%) pixels has been addded when the conversion is
725 calculated from interleaved events
726
727 - star: fixed a bug which caused MEffectiveOnTime containers not to
728 be written. In the worst case they were skipped almost all, in the
729 best case they were all ok. It depends on how often the new value
730 was assigned just with an event which was skipped later by another
731 task
732
733 - star: new histograms MHPointing and MHRate
734
735 - star: New tab (Currents) displaying the time evolution of the mean
736 DC currents
737
738 - star: New tab (MeanRms) displaying the time volution of the mean
739 Pedestal Rms
740
741 - star: Output now contains MReportStarguider
742
743 - star: Improved muon analysis. Due to the absense of a constant
744 for the gaus fit for arc width and the fact that the arcwidth
745 plot was a histogram instead of a profile the resulting psf
746 became pedestal rms dependant
747
748 - ganymed: added new plot (MHPhi) for wobble mode as described in
749 http://www.astro.uni-wuerzburg.de/results/ringmethod/
750
751 - ganymed: corrects now (correctly?) for the misspointing in
752 May/April 05
753
754 - ganymed: Two new default templates for ganymed.rc are avilable:
755 ganymed_onoff.rc and ganymed_wobble.rc
756
757 - ganymed: The first version of MFMagicCuts has been released
758
759 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
760
761 - ganymed, sponde: There are two new options to determin the number
762 of bins for the signal region (NumBinsSignal) and the number of
763 total bins (NumBinsTotal) in the MHThetaSq histogram
764
765 - ganymed: optimized palettes for MHDisp
766
767 - ganymed: Fixed an important bug when using ThetaSq as fit function:
768 The result for the sigma of the gauss(sqrt(x)) fit was a factor
769 sqrt(2) to large
770
771 - ganymed: The false source plot (MHDisp) is now based on Disp
772 and a background model determined in the first loop is
773 subtracted
774
775 - ganymed: MFMagicCuts are now available in the cvs. The correct
776 solution for the disp ambiguity problem is now calculated using
777 the third moment. The third moment cut therefor is skipped.
778
779 - ganymed: Output now contains "Disp [MParameterD]" which sign is
780 already determined by the third moment along the major axis and
781 so its actual sign is aligned along the major axis of the shower.
782
783 - ganymed: If starguider data is available it is taken into account
784 when calculating the source position. This is especially important
785 for wobble data at high zenith angles and culmination data.
786
787 - ganymed: If available the starguider data is taken into account as
788 good as it is possible without a starguider calibration. To switch
789 it off add
790 MPointingDevCalc.MaxAbsDev: -1
791 to your ganymed.rc
792
793 - sponde: the zenith angle distribution is now weighted instead of
794 choosen by default. This gurantees higher statistics in the highest
795 and lowest energy bins. To switch this behaviour off use...
796
797 - sponde: now automatically displays the energy threshold
798
799
800
801 *** Version 0.9.3 (2005/06/03)
802
803 - general: MMcEvt now derived from MMcEvtBasic which should
804 have no influence on compatibility with older camera files
805
806 - general: Implemented a new option to MReadReports which allows
807 to force reading of the first event of some trees (eg. Drive-tree)
808 before any other tree.
809
810 - general: Made a fix to MPointingPosCalc which assumes that the
811 run-type is real-data if Process is called before ReInit, such
812 that also the very first Drive-events in a run are treated
813 correctly.
814
815 - shoplot now displays the filename in the title bar of the window
816
817 - merpp: new options: --auto-time-start --auto-time-stop which
818 allow to cut updating with slow-control at the start- or
819 (previousle --auto-time only allowed: and) stop-time of
820 the run stored in the runheader.
821
822 - callisto: changed default of fgFallTimeHiGain in
823 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
824 already set as default in callisto_Dec04Jan05.rc
825
826 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
827 now changes the filename for new weights automatically for
828 cosmics, MC and for different calibration colors.
829
830 - callisto: a problem with the order of some code cause the
831 name of the weights file in MPedestalY2 to be ignored.
832 Wrongly the calibration_UV weights were used instead
833 of the cosmics weights set in callisto.rc.
834
835 - callisto: should allow ct1 pulser data when the color is
836 explicitly set also for pretty new runs
837
838 - callisto: a new option (MCalibrateData.ScaleFactor) allows
839 to introduce an additional scale factor (should be around 1)
840 to adapt for slight deviations in different extractors from
841 the MC calibration. For MC calibrations the scale factor
842 is fixed to 1
843
844 - callisto: MFCosmics should handle very high signals a bit
845 more accurate now
846
847 - callisto: when calculating the mean pedestal rms for different
848 pixel sizes or sectors also kUnsuitableEvt is now taken into
849 account - not only kUnsuitableRun
850
851 - callisto: '-raw' option is now the default
852
853 - callisto: A dead pixel check has been implemented in MJPedestalC2.
854 This has the advantage that mean values in the calibration (eg
855 arrival times) are calculated more accuratly.
856
857 - callisto: In the resource file callisto_Dec04Jan05.rc
858 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
859
860 - callisto: new Hi-/Lo-Gain intercalibration constants
861 hilocalib_sp1.root and hilocalib_sp1_mc.root
862
863 - callisto: changed default for MJPedestalY2.MaxEvents
864 from 2000 to 5000 like in callisto_Dec04Jan05.txt
865
866 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
867 has changed from 9.0 to 6.0. This is necessary to exclude two very
868 ringing pixels in September which - when kept - destroy the image
869 cleaning around them (Markus G.)
870
871 - callisto: (!) The Muon analysis of all data taken so far has
872 suggested that different extractors give slightly different
873 absolute results after calibration, due to there different
874 handling of the calibration- and cosmics pulse shape. Although
875 the over all calibration seems to be a bit to pesimistic (or
876 the MC seems to be a little bit - 3-5% - too much attenuated).
877 There for correction factors have been introduced which correct
878 the calibration constants by
879 0.956937799 for Digital Filter (callisto.rc)
880 and
881 0.904159132 for Spline (callisto_Dec04Jan05.rc)
882 calibration. The main advantage is, that both data types can
883 be easily analysed together and compared to the same MC sample.
884 The factors are choosen such, that the reference is now a
885 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
886
887 - star: fixed a bug which caused the first bin of the histograms
888 vs time to disapear in PostProcess. This gave wrong results
889 on the screen. The output and all following programs not
890 directly accessing the histograms haven't been affected
891
892 - star, ganymed: Made sure that always the first Drive-tree event
893 is read and Processed before the first data event was read.
894
895 - ganymed: implemented the possibility to replace the standard
896 false source plot with a different one. For example: If
897 you want to use a Disp based FS plot use the resource:
898 NameHistFS: MHDisp
899 For details about the requirements of these plots look
900 at the corresponding classes
901
902 - MJOptimize: For On/Off and Wobble optimization MJOptimize
903 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
904 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
905 case MAlphaFitter is setup correctly. For On-Only optimization
906 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
907 RunOn() instead of Run(). For energy estimation MJOptimize
908 has been replaced by MJOptimizeEnergy
909
910 - sponde: The input MC spectrum can now be weighted to fake a
911 different spectrum. This is done via MMcSpectrumWeight. For
912 more details see the class description and sponde.rc
913
914 - sponde: The paremeter comparsion plots are not scaled by
915 their entries anymore. Instead the MC plot is scaled by using
916 the result spectrum of the analysis. If the input MC spectrum
917 and the result spectrum has different slopes the absolut
918 normalization is normally wrong.
919
920
921
922 *** Version 0.9.2 (2005/05/20)
923
924 - general: Changed the default paths for calibrated data and image
925 files. (The implemented access to these files doesn't yet exist)
926
927 - general: support for MRunIter has been removed from the job classes
928 (use the setter functions of MSeqeunce instead)
929
930 - general: ProcessFile has been renamed to Process in all job classes,
931 because ProcessFile is missleading
932
933 - general: The storage of the palette in MHCamera is now possible
934
935 - general: new bits describing unsuitable and unreliable pixels have
936 been introduced in MBadPixelsPix: kPreviouslyExcluded,
937 kDeadPedestalRms, kFluctuatingArrivalTimes
938
939 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
940 versions newer than V200404070
941
942 - general: support for cc file versions newer than V200504130. Added
943 support for active loads (MCameraActiveLoad) and central pixel
944 (MCameraCentralPixel)
945
946 - general: added new histograms for image parameters versus size
947 (MHVsSize)
948
949 - general: The eventloop now automatically calls PrintStatistics
950
951 - Status Display: Improved support for printing:
952 + A default can now be set in .rootrc (for more details see
953 MStatusDisplay::PrintPS)
954 + A print dialog is opened so that printer and command line
955 can be canged
956
957 - showlog: improved such that it handles different verbosity levels
958 more accurate now. This mean you can suppress output when
959 using showlog.
960
961 - showplot: improved
962 + The new graphics formats have been implemented
963 (pdf, svg, png, jpg and xpm)
964 + Implemented an interface for printing. Because you can change
965 the printing command from the command line you can use all
966 the nice postscript tool. To print a booklet for example call:
967 showplot -b --print --print-cmd="cat %f" filename.root | lpr
968 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
969 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
970
971 - callisto: fixed a bug in the recognition of the calibration bit
972 pattern. Concerns only intensity calibration. (The strength of the
973 intensity has been updated in some cases)
974
975 - callisto: add a filter against PIN Diode events when running over
976 calibration runs since some of the recent calibration runs have
977 been taken with Pin Diode.
978
979 - callisto: added support for the runs 39942, 39944, 44834, 39941,
980 39943, 44833 in the calibration (MCalibColorSet)
981
982 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
983 been set to 1e-18 in callisto_Dec04_Jan05.rc
984
985 - callisto: in callisto_Dec04Jan05.rc: set value for
986 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
987 statistics for the calculation of the mean pulse time
988 of the cosmisc
989
990 - callisto: the charge limit in the calibration has been raised
991 from 2.5 to 4.5
992
993 - callisto: new setup read from callisto.rc
994 + MCalibCalcFromPast.fNumEventsDump
995 + MHCalibrationChargeCam.NumHiGainSaturationLimit
996 + MHCalibrationChargeCam.NumLoGainSaturationLimit
997
998 - callisto: MExtractTimeAndChargeSpline extractor:
999 + The integration ranges were shifted by 0.2 FADC slices to the right.
1000 + unreliable handling of floating point values caused different
1001 results on different platform or with different compiler options:
1002 The new algorithm is numerically exact and more accurate because
1003 it doesn't calculate the integration position by multiple times
1004 adding the step-size (which results in numerical uncertanties
1005 exspecially if multiplied with large numbers)
1006 + A lot of fixes have been introduced which effects integrating the
1007 spline at the edges of the valid range. In this case any memory
1008 was randomly accessed. This behaviour can be tested replacing
1009 all MArrayF by TArrayF which perform a range check (but of course
1010 they are a lot slower)
1011 ! No result obtained with the Spline before can be trusted! Due to
1012 random memory access it might by completely random!
1013
1014 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1015 + extraction range in the high gain to 4.
1016 + weights file to cosmics_weights46.dat
1017
1018 - callisto:
1019 + introduce the check for fluctuating arrival times.
1020 + set charge limit to from 2.5 to 4.5
1021 + introduce asymmetric exclusion due to "deviating number of phes":
1022 Default: -9.0 +4.5
1023 + make deviating number of phes unsuitable (see David's findings).
1024
1025 - callisto: fixed the display of unsuitable pixels. The old change
1026 to a real profile in MHCamera broke it.
1027
1028 - callisto: The cosmics filter is used in MJCalibration now
1029 independant of the pulser color (formaly it was used only for
1030 CT1-pulser data). The threshold of number of max empty pixels
1031 has been raised from 2% to 5% in MJCalibration. The maximum
1032 fraction of rejected event is 50% otherwise the calibration has
1033 failed. The filter now ignores unsuitable pixels.
1034 Setup the filter from callisto.rc using "ContCosmics"
1035 (see MFCosmics::ReadEnv)
1036
1037 - callisto: changed default for fgOffsetFromLogain back
1038 from -2.8 to -1.8 in digital filter.
1039
1040 - callisto: for the common extractors
1041 + MExtractFixedWindow
1042 * MExtractTimeAndChargeSlidingWindow
1043 * MExtractTimeAndChargeSpline
1044 * MExtractTimeAndChargeDigitalFilter
1045 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1046 and fResolutionPerPheLoGain
1047
1048 - callisto: Updated the hi-/lo-gain intercalibration constants
1049 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1050 hilocalib_df6.root
1051
1052 - callisto: The default lo-gain extraction window for the
1053 MExtractTimeAndChargeSlidingWindow extractor has been increased
1054 from 6 to 8 to take the stretch of the pusle into account
1055
1056 - callisto (!!!): fixed an important bug in the setting of the
1057 incoming pedestal pointer to the signal extractor extracting
1058 pedestals. This bug caused the pedestals not to be subtracted
1059 correctly in the calibration afterwards. The effect was about 10%
1060 too high conversion factors for the digital filter and the spline
1061 and more than 40% for the sliding window.
1062 The bug existed since end of February! (Markus G.)
1063
1064 - star: added muon support to star. A new tab "MHMuonPar" is
1065 displayed. The lower right plot is an estimate of the point spread
1066 function. A reference value is displayed. To get the real PSF
1067 you must compare with MC. The setup for the muon analysis
1068 is done in star.rc. More informations can be found in
1069 MHSingleMuon and MHCalibParCalc
1070
1071 - star: The weather data is now displayed in star
1072
1073 - star: MEventRateCalc handles the calculation of the event rate more
1074 accurate now in case of the start of a new run inside a sequence
1075
1076 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1077 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1078 changed only minimally
1079
1080 - ganymed: (MJCut and MJOptimize) now displayes the number of
1081 excess events versus size. The energy estimation is done in
1082 MJSpectrum (sponde)
1083
1084 - ganymed: got support for using other variables than Alpha, eg. Theta.
1085 Therefor you need a class deriving from MHAlpha which supports
1086 this variable (one is already existing: MHTheta, which is now the
1087 default in ganymed). It is setup through ganymed.rc
1088
1089 - added a full featured spectrum program (sponde) which reads
1090 ganymed output and monte carlos and compiles a spectrum
1091
1092
1093
1094 *** Version 0.9.1 (2005/04/14)
1095
1096 - Fix bug on the arrival time reconstruction when using Digital
1097 Filter (in some marginal cases (10%) times were reconstructed shifted
1098 by 0.2 slices)
1099
1100 - all executables now return 2 where in previous versions -1 has
1101 been returned (gave problems with shell-scripts)
1102
1103 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1104 also done with a intercalibration input file
1105
1106 - a bug in the time fine adjustment of the digital filter has been fixed
1107
1108 - a lot of small fixes to calling TPad::Divide with a margin==0
1109
1110 - MStatusDisplay now shows the memory usage
1111
1112 - added a memory leak statistic after the eventloop
1113
1114 - MHadronness replaced by MParameterD
1115
1116 - MEnergyEst replaced by MParameterD
1117
1118 - wobble mode can now be switched on from the data-set
1119
1120 - switched on bad pixel detection for a pedestal level
1121 which is more than 5 times the variance
1122
1123 - Fixed default paths to be correct for the new data center
1124
1125 - Fixed handling of drive data. The pointing position in now
1126 copied to MPointingPos inside star for real and MC events
1127
1128 - made sure, that the sequences in a dataset are sorted by
1129 their number to ensure the correct synchronization
1130
1131 - added all resource files necessary to handle spline extraction
1132 of signal for the late 2004 and the early 2005 data
1133
1134 - update the reference lines for the december data
1135
1136 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1137 This is important for the Dec. and Jan. data where the calibration
1138 pulse position changes much.
1139
1140 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1141 filter. This corrects only an defective extraction of the MC at
1142 low-gain signals lower than 90 phes.
1143
1144 - fixed some slowdown in calibrating data with interleaved events from
1145 Jan and Dec. As a workaround made the pretty palette the default.
1146 The inverse Deep Blue Sea has a bug which slows down long calibration
1147 runs a lot.
1148
1149 - implemented new values from new starguider report as defined
1150 in TDAS00-07 V7.1 (eg SkyBrighness)
1151
1152 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1153 in starguider report (If you merpp the same reports with this version
1154 you'll get the correct units (arcmin) but a different result
1155 than with old versions (wrong units))
1156
1157 - Now the status display can also write PNG, JPEG and XPM (other file
1158 formats are still unsupported by root)
1159
1160 - added a lot of scripts and macros in directory datacenter used
1161 for automatic processing
1162
1163
1164
1165 *** Version 0.9 (2005/03/23)
1166
1167 - Calibration is now done autmatically into photo-electrons like
1168 decided by the Collaboration Board
1169
1170 - Reference lines in the display can be read from resource file
1171
1172 - Interlaced calibration events can be handled by callisto
1173
1174 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1175 and applied in callisto.
1176
1177 - class MJCalibTest can be called by callisto
1178
1179 - callisto can now run with three data types: rawdata, rootdata, MC
1180
1181 - added two classes mreport/MReportStarguider.cc and
1182 mreport/MReportStarguider.h for implementing starguider-data
1183
1184 - the output of merpp-update now contains starguider information:
1185 MReportStarguider and MTimeStarguider
1186
1187 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1188 values were lower than they should. This was more visible for high
1189 energy (Size) events.
1190
1191 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1192
1193 - added a new loop to callisto to support the correct extraction of
1194 the pedestal and pedestal rms through the signal extractor
1195
1196 - added class to perform fourier tranformation of a hexagonal structure
1197 (MHexagonalFT)
1198
1199 - added class to perform fourier tranformation of a hexagonal structure
1200 in a tasklist (MHexagonalFTCalc) example: hft.C
1201
1202 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1203 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1204 small pixels, example: extendcam.C
1205
1206 - added possibility to write data to memory (TTree) using MWriteRootFile
1207
1208 - added possibility to read a TTree stored only in memory by MReadTree
1209
1210 - new classes to deal with the interleaved calibration events:
1211 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1212
1213 - implemented filters to callisto to skip calibration events
1214
1215 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1216 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1217 the slices by statistics
1218 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1219 signal extractor without randomization
1220 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1221 with the signal extractor with randomization (extraction window is
1222 randomly fixed)
1223 The three kind of pedestal is not yet implemented (for speed reasons) as
1224 long as nobody really needs it:
1225 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1226 extracted with the signal extractor with randomization
1227
1228 - callisto now finds the pulse position in the data automatically
1229
1230 - implemented data reduction in calibrated data by reducing the precision
1231 of the stored floating point values (pedestal, rms and signal) to
1232 roughly 0.5%
1233
1234 - fixed showplot to make file format conversion (eg. converting a
1235 status display stored in a root file into a postscript file) in
1236 batch mode possible:
1237 showplot -b --save-as-ps[=outfile.ps] infile.root
1238
1239 - Allow class names as part of filter rules, eg
1240 (MFSupercuts) && (MHillas.fSize>100)
1241
1242 - fixed a lot of stuff to allow all programs to process MonteCarlo
1243 camera files.
1244
1245 - enhanced possibility to debug reading of resource file
1246
1247 - MDataChain should handle priorities of operator more
1248 accurate now
1249
1250 - completely revised the container in which the signal is stored
1251 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1252 * the new implementation is faster and
1253 * needs less storage space
1254
1255 - FIRST version which can process Monte Carlos through the
1256 whole chain of programs (callisto, star, etc)
1257
1258 - implemented new image parameters for the border length of
1259 the shower image (MNewImagePar2)
1260
1261 - implemented wobble-mode in ganymed
1262
1263 - new class (MJOptimize) taking care of all optimization processes
1264
1265
1266
1267 *** Version 0.8.6 (2004/10/05)
1268
1269 - New combined signal and time extractor
1270 MExtractTimeAndChargeDigitalFilter
1271
1272 - The Report for the trigger section in the CC run summary has been
1273 updated, and now the IPRs (Individual Pixel Rates) are available.
1274
1275 - new macros for database interaction: filldotrun.C, filldotrbk.C
1276
1277 - added new program which can convert colored output which was redirected
1278 into a file back into colored text (for example to display it with
1279 more): showlog
1280
1281 - added new program to display an MStatusArray of plots (stored with
1282 MStatusDisplay) from a file: showplot
1283
1284 - Added support for Sequences (MSequence). Sequences are blocks of run
1285 files containing the same calibration and belonging to the same
1286 source
1287
1288 - Added a new task (MTaskEnv) which can be used in setup files to switch
1289 between different tasks (for example to choose a signal extractor)
1290
1291 - Implemented automatic file splitting in MWriteRootFile
1292
1293 - After image cleaning an island index is assigned to all used pixels.
1294 The index corresponds to the order of the islands in size.
1295
1296 - added a cleaning which takes signal height _and_ arrival time into
1297 account: probability cleaning (for more details see MImgCleanStd)
1298
1299 - added a cleaning which takes takes the absolute number of photons
1300 times the area ratio as cleaning level
1301 (for more details see MImgCleanStd)
1302
1303 - Changed calculation of image parameters such, that it can be done
1304 for all used pixels or the pixels with a defined island index only
1305
1306 - implemented new image parameters displaying the number of islands,
1307 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1308
1309 - event display in executable changed to support also calibrated files
1310 (done with MJCalibrateSignal)
1311
1312 - added program doing the calibration and the signal extraction
1313 and signal calibration: callisto Most part of the setup is done
1314 by a resource file: callisto.rc
1315
1316 - implemented support for pixels with negative IDs (Raw file format
1317 version 4)
1318
1319 - implemented an new option in merpp (--auto-time) to get the time
1320 range for cc and/or caco data from the run header of the raw data
1321
1322 - New star-program (star and MJStar). Taking calibrated data from
1323 callisto/MJCalibrateSignal as input. The setup is done through
1324 a resource file: star.rc
1325
1326 - Added possibility to setup the eventloop in the mars-executable
1327 Camera Display by a resource file: mars.rc
1328
1329 - The the mars-executable Camera Display can now also read
1330 calibrated data files written by callisto/MJCalibrateSignal
1331
1332 - Added a new class which can calculate the source position in
1333 the camera from a pointing model known to be correct and
1334 the pointing model used for observations (MSrcPosFromModel)
1335
1336 - added a new version of the class calculating the effective on-time
1337 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1338 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1339 MHTimeDiffTheta.
1340
1341 - added the possibility to count how often a signal is above (or
1342 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1343 can replace MHTriggerLvl0)
1344
1345 - added ore convinient ways to set the axis-titles of your histograms
1346 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1347 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1348
1349
1350
1351 *** Version 0.8.5 (2004/08/06)
1352
1353 - new Signal Extractors: MExtractFixedWindowSpline
1354 and MExtractAmplitudeSpline
1355
1356 - implementes interleave in merpp to be able to merpp parts of a file
1357
1358 - implemented force-functionality to merpp
1359
1360 - star display to display star catalogs (MAstroCatalog)
1361
1362 - star display to 'mirror' stars to the camera (MAstroCamera)
1363
1364 - implemented a new cleaning option which allows cleaning scaled with
1365 the real ratio of the rms depending on the pixel size, not only the
1366 square root of the pixelsize (MImgCleanStd, MCameraData)
1367
1368 - removed obsolete MBlind* classes
1369
1370 - Signal extractor taking the AB flag into account implemented (this makes
1371 an odd number of slices for signal extraction possible
1372 (MExtractSignalABcorr)
1373
1374 - implemented a class extracting the pedestal from the raw-data (events)
1375 itself using empty lo-gain (MpedCalcFromLoGain)
1376
1377 - Added mean values to MPedPhotCam
1378
1379 - Added Makefile for Darwin (this OS is NOT officially supported!)
1380
1381
1382
1383 *** Version 0.8.4 (2004/04/19)
1384
1385 - new fast arrival time extractor using cubic splines:
1386 MExtractTimeFastSpline
1387
1388 - implementes multi-argument support in MDataChain
1389 ("pow(a, b)")
1390
1391 - implemented double reference support in MDataChain
1392 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1393
1394 - added support in MF for expressiond like
1395 "MHillas.fWidth<2*<MHillas.fLength"
1396
1397 - MDataChain is now able to support variables like [0], [1], ...
1398 which can be used in fit functions as parameters. The interface
1399 is implemented through the new virtual function
1400 MParContainer::SetVariables
1401
1402 - added new class MArrivalTimeCam/MArrivalTimePix:
1403 Storage containers to hold the ArrivalTime of the camera/pixel
1404
1405 - added new classes for the calibration of relative arrival times:
1406 MCalibrationRelTimePix and MCalibrationRelTimeCam
1407
1408 - added new classes to extract the signal of the blind pixel and the
1409 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1410
1411 - added new classes for the bad-pixels treatment (MBadPixels*)
1412 which are more powerfull than the old ones (MBlindPixel*)
1413 and will replace them.
1414
1415 - added filter against cosmics: MFCosmics
1416
1417 - added new class MArrivalTimeCalc2:
1418 Calculates the arrival time as the signal weighted mean of the time
1419 slices in the maximum window
1420
1421 - added a new macro call pointspreadfucntion.C that fits with a 2D
1422 gaussian the DC spot for an star. It gives you the RMS of
1423 the PSF and the center of the star, very useful for misspointing
1424 studies.
1425
1426 - added support for multi-telescope camera files. Added classes
1427 MStereoCalc and MStereoPar, classes to calculate and store shower
1428 parameters calculated from the data of two telescopes, for the MC
1429 studies regarding the MAGIC clone.
1430
1431 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1432 MC data calibrated in photons instead of ADC counts.
1433
1434 - added three macros to show the calibration and analysis chain of
1435 MC data. The macro starmc.C does both calibration and analysis, producing
1436 an output containing Hillas parameters for each event. The macro
1437 mccalibrate.C does just the calibration and writes out a file containing
1438 pixel information in photons instead of FADC data. The macro starmc2.C
1439 reads in such a file and produces an output with Hillas parameters.
1440
1441 - added MPedPhotCalc to compute pedestals in units of photons, see
1442 macro pedphotcalc.C
1443
1444 - added all class to perform the calibration, see macro calibration.C
1445
1446 - added class MFFT to perform Fast Fourier Transforms
1447
1448 - added class MSimulatedAnnealing to perform simulated annealing
1449 minimizations
1450
1451 - added new macro bootcampstandardanalysis.C which holds the skeleton
1452 of the analysis chain discussed in the december bootcamp.
1453
1454 - added support for DAQ raw data file format V2
1455
1456 - implemented an arbitrary time stamp for the events from raw-data
1457 files with file version<3. It is calculated from the run number,
1458 the date of start and the FADC clock tick from the first module
1459
1460 - implemented the correct decoding of the event time-stamp
1461 coming from the DAQ for raw-data files with file-version>2
1462
1463 - added a new classes storing the pedestals in units of photons:
1464 MPedPhotPix, MPedPhotCam
1465
1466 - added support for DC current files from the camera control
1467
1468 - added support for start- and stop-time when merpping report files
1469
1470 - added MReportCC storing the weather data from the CC-REPORT
1471
1472 - added class to fill trainings and test matrices (MTFillMatrix)
1473
1474 - added a filter performing a software trigger (MFSoftwareTrigger)
1475
1476 - Added classes to perform parts of the standard analysis (Jobs):
1477 + MJPedestals
1478 + MJCalibration
1479 + MJExtractSignal
1480 Note: All of them are preliminary!
1481
1482 - Added Iterator to iterate over files giving only the run-number
1483
1484 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1485 the evolution of a sector vs time
1486
1487
1488
1489 *** Version 0.8.3 (2003/12/05)
1490
1491 - adapted Random Forest classes to allow the use with MC
1492 multi-telescope files which can be produced with the coming
1493 camera version 0.7.
1494
1495 - added classes to read and interprete central control report files
1496 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1497
1498 - enhanced merpp (the executable) to support .raw and .rep files.
1499
1500 - added classes for light calibration (MCalibration* and
1501 MHCalibration*) by Markus Gaug. Further work has to be and will
1502 be done soon.
1503
1504 - Added a preliminary 'synchronizer' (MReadReports) which will
1505 replace MReadMarsFile as soon as it is finished.
1506
1507 - Added a tutorial macro demonstrating how report files are merpped
1508 and how they can be read from the root file in the correct order
1509 of time (readrep.C)
1510
1511 - Added a generalized histogram (similar to MH3) called MVsTime
1512 which allows to plot variables (or rules - MDataChain - of
1513 variables) vs time. For an example have a look at tempvstime.C.
1514
1515 - Changed the name of the event trees:
1516 + Events --> Events
1517 + PedEvents --> Pedestals
1518 + CalEvents --> Calibration
1519
1520 - changed name of MTime in the event trees from MRawEvtTime to MTime
1521
1522 - added displaying the sector indices to the mars event display
1523
1524 - Magic Online Analysis (MOnA) implemented in a first version
1525 (see mona.cc, MOnlineDump and MOnlineDisplay)
1526
1527 - added classes to calculate event rate
1528 (preliminary: MEventRateCalc, MEventRate)
1529
1530 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1531
1532 - added classes dealing with the telescope pointing position (MPointing*)
1533
1534 - implemented the 'final' Mars time stamp based on some experiences with
1535 the new 'Synchonizer'
1536
1537
1538
1539 *** Version 0.8.2 (2003/11/10)
1540
1541 - accelerated standard analysis by a factor of 6-8 ...
1542 + doing precalculations in MGeomCam for the pixel area ratio
1543 + creating a look up table for the single pixels in MCerPhotEvt
1544
1545 - added task to calculates weights in case you want to 'change'
1546 the energy spectrum of a monte carlo file
1547 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1548
1549 - added a new executable star which implements the
1550 star.C macro as precompiled executable. Currently a flexible
1551 setup is not possible, but a 'input card' setup will follow.
1552
1553 - Starting to implement Multi-Telescope-Support based on the
1554 upcomming camera version 0.7. The base for a general support
1555 is implemented and the star-functionality is proven to work.
1556
1557 - Replaced Event-Display in and Camera-Display in the Mars GUI
1558 executable by a more convinient display base on MStatusDisplay.
1559
1560 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1561
1562
1563
1564 *** Version 0.8.1 (2003/10/20)
1565
1566 - added signal subtraction for pure on data by means of fitting
1567 the background in the off region or by performing a combined
1568 signal/background fit. Provides necessary histograms for
1569 obtaining energy spectra and a light curve.
1570
1571 - added classes to perform and study the selection of the
1572 2nd Level Trigger on MC data (example in triglvl2.C macro)
1573
1574 - added pedestal calculation
1575
1576 - implemented "democratic cleaning" (tail cut value proportional
1577 to pixel area) according to Wolfgang's suggestion.
1578
1579 - added Sigmabar treatment (calculation and basic histogramming)
1580
1581 - added basic routines to apply padding
1582
1583 - added first implementation of MARS-based source visibility plotter
1584 (needs to be linked against slalib, preliminary version)
1585
1586 - enhanced functionality of data chains: random numbers, conversion
1587 functions and access to MHMatrix objects
1588
1589 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1590 numbers under certain circumstances (runs with 0 events included)
1591
1592 - fixed a bug in the general filter MF (didn't work on some systems
1593 at all)
1594
1595 - fixed a bug in chaining files, which caused the analysis to crash or
1596 ignore files
1597
1598 - implemented more geometry classes describing the parameters used
1599 to simulate the PMT camera
1600
1601 - added new Monte Carlo classes containing the setup of the different
1602 programs in the MC chain.
1603
1604 - added a (preliminary) general task to evaluate chi-square of a given
1605 parameter in an eventloop.
1606
1607 - first implementation of a container describing the observatory
1608 location (Long, Lat, etc)
1609
1610 - added Random Forest - method for g/h-separation
1611
1612 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1613 (this means, that it is compiling, but not yet fully tested)
1614
1615 - added a new status display which can show the present status
1616 of histograms while an eventloop is running (MStatusDisplay,
1617 an example can be found at status.C)
1618
1619 - reorganized directories:
1620 classes describing the image --> mimage
1621 classes containing Monte Carlo Histograms --> mhistmc
1622 classes for Random Forest method --> mranforest
1623
1624 - added (event-)weights to fill histograms
1625
1626 - colors in logging output to screen
1627
1628 - changes to the Image Parameter declaration:
1629 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1630 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1631 + MHillasExt now derives from MParContainer instead of MHillas
1632 --> Files written with the old definition are more or less unreadable
1633
1634 - reading of reflector files
1635
1636 - display data from reflector files in the camera
1637
1638 - implemented currents (and display them in the camera)
1639
1640 - logarithmic scale in camera
1641
1642 - added class to iterate through directory contents (MDirIter)
1643
1644
1645
1646 *** Version 0.8 (2002/11/18)
1647
1648 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1649
1650 - corrected 48(!) wrong entries in the Next Neighbor table of the
1651 Magic Camera (all in the inner part of the outer ring, mostly
1652 missing a single NN)
1653
1654 - Fixed a bug in the table describing the Next Neighbours of the
1655 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1656 have any neighbour)
1657
1658 - changed trigrate.C: now it calculates the pure NSB triggers from
1659 a camera file (generated with no showers), so there is no need
1660 to introduce them by hand in the BgR array (for more details
1661 please ask Abelardo)
1662
1663 - added MHHadronness (and MHadronness) as a general facility to evaluate
1664 the quality of a gamma-hadron seperation method
1665
1666 - changed MWriteAsciiFile to accept rules (MDataChain)
1667
1668 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1669 must be replaced by calles to MWriteAsciiFile::AddColumn and
1670 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1671 changed.
1672
1673 - Implemented generalized event-matrices (one row per event)
1674 (MHMatrix)
1675
1676 - implemented the one dimensional composite probabilities
1677 (MHCompProb, MCompProbCalc, comprob.C)
1678
1679 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1680 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1681
1682 - Added a camera display displaying the pixel numbers to the
1683 event display gui.
1684
1685 - Added Monte Carlo Informations to event display gui
1686
1687 - Changed the camera display to display the pixel numbering
1688
1689 - Added three buttons to the camera display to change the palette
1690
1691 - Added the number of used and core pixels after image cleaning
1692 to MHillas
1693
1694 - Changed the algorithm used in MHillas according to TDAS 02-03
1695
1696 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1697
1698 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1699
1700 - Added fCosDeltaAlpha to MHillasSrc
1701
1702 - The numbers of photons used to calculate fConc and fConc1 in
1703 MHillasExt are now scaled with the pixel size, so that one get
1704 a four times smaller value for the bigger pixels in the outer ring.
1705
1706 - added new task to smooth the camera contents (MCameraSmooth)
1707
1708 - added possibility to use interpolated pixel values for blind pixels
1709 instead of removing it completely from the analysis
1710
1711 - Implemented the possibility to save the whole eventloop with
1712 its setup to a file. This information can be read and from
1713 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1714 and MEvtLoop::MakeMacro. If you find something not working, please
1715 report - this stuff is still in a beta phase.
1716
1717 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1718 file having crab starfield, but also for all following files - fixed
1719
1720 - MTaskList::PrintStatistics can now be instructud to print also the
1721 title, too: use PrintStatistics(0, kTRUE)
1722
1723 - Changed the image cleaning so that pixels with to many 'used'
1724 neighbors are left used (to get rid of 'holes' in events)
1725
1726 - Introduced more output to the camera displays
1727
1728 - Added an array of histograms (eg one hist per run), MHArray
1729
1730 - Added a _preliminary_ version of the reader for CT1 PreProc files
1731 (MCT1ReadPreProc)
1732
1733 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1734 (thanks to Raquel)
1735
1736 - added the first energy estimator (MEnergyEstParam, estimate.C,
1737 estfit.C) using a parametrization
1738
1739 - Added some new Monte Carlo paremeter containers used to store
1740 setup information from the MC chain (MMcConfigRunHeader,
1741 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1742
1743
1744
1745 *** Version 0.7 (2002/04/30)
1746
1747 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1748 the pedestal mean value was saved incorrectly. For files from
1749 this versions we substract 0.5 from the pedestal mean.
1750 WARNING: This may effect your results, so don't wonder...
1751
1752 - First implementation of an algorithm using only triggered events
1753 for the collection area calculation
1754
1755 - Ascii Output can now also be used for parameter containers which
1756 doesn't overload MParCointainer::AsciiWrite
1757
1758 - The Ascii Output is now also capable of writing single data members
1759 of one container
1760
1761 - You are now able to change the order of the values written to the
1762 ascii file
1763
1764 - You can now specify a conversion factor for each data member written
1765 to an ascii file. This may be usefull to change the units of the
1766 data member (eg. degrees instead of millimeters in case of the
1767 hillas parameters)
1768
1769 - Replaced old MHillas by a new structure which allows you to extend
1770 the parameters stored in MHillas very easily:
1771 see MHillas and MHillasExt
1772
1773 - Added classes to handle source dependancy of image parameters:
1774 see MHillasSrc
1775
1776 - Added container (MBinning) to have a standard input for the binning
1777 in different histograms (eg. the Energy bins should be the same in
1778 all histograms)
1779
1780 - Changed Hillas histograms from mm to deg
1781
1782 - Added the flexible binning to the hillas histograms
1783
1784 - Added a filter for the alpha parameter (MFAlpha)
1785
1786 - It is now possible to write single data members of a class object to
1787 an output stream instead of the whole container only
1788
1789 - Added a generalized filter for a data member:
1790 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1791
1792 - Added a generalized Filter parser for more difficult filter rules
1793 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1794
1795 - Added new Monte Carlo histograms:
1796 MHMcEnergyImpact and MHMcEfficiency
1797
1798 - Added many new histograms needed for the flux calculation.
1799
1800 - Added a generalized histograms which can fill and show up to three
1801 data members in either a one-, two- or three-dimensional histogram, eg:
1802 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1803
1804 - Added:
1805 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1806 * calculation of <Theta> as a function of time (MHThetabarTime)
1807 they are needed in the flux calculation in
1808 order to select for a given bin in Theta (or time) the appropriate
1809 effective collection area, which is assumed to be given as a function
1810 of Theta and the true energy
1811
1812 - Added calculation of the migration matrix in the energy
1813 (MHMcEnergyMigration):
1814 the migration matrix describes the migration from the true (E_true)
1815 to the estimated energy (E_est); it is needed to determine the
1816 distribution of E_true from the measured distribution of E_est
1817 by unfolding
1818
1819 - changed the color palette in the camera display to DeapSea.
1820
1821
1822
1823 *** Version 0.6 (2002/01/15)
1824
1825 - Introduce the option of disable pixels (MBlindPixels and
1826 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1827 able to deal with Star Field NSB.
1828
1829 - Fixed a bug in the pedestals substraction
1830
1831 - Introduced verbosity levels
1832
1833 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1834
1835 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1836 work correctly (thanks to Abelardo)
1837
1838 - Introduced correct treatment of the diffuse Night Sky Background
1839 and NSB (MMcPedestalNSB)
1840
1841 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1842
1843 - Introduced MMcRunHeaders which contains monte carlo run informations
1844
1845 - Added a 'Print'-Task (MPrint) which calls the Print function
1846 of a parameter container for each event
1847
1848 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1849
1850 - changes to be more efficient with root 3.02/06
1851
1852 - root 3.02/06 fixes:
1853 + the memory leak when reading MRawEvtData
1854 + loosing more time than necessary to update the progress bar
1855
1856 - MWriteAsciiFile is now capable of writing more than one container
1857 in a line. For example: To be able to write Monte Carlo and
1858 Hillas values (energy and alpha) in one line.
1859
1860
1861
1862 *** Version 0.5 (2001/11/06)
1863
1864 - Added new GUI functionality (Analysis)
1865
1866 - Added a camera display to be able to display events in the camera
1867 together with the calculated hillas ellipse
1868
1869 - Added a 'Clone'-Task (MClone) which can clone a parameter container
1870 object at any state of the analysis, so that the output are several
1871 states
1872
1873 - Fixed a bug in the collection area error calculation
1874 (Thanks to Ciro and Abelardo)
1875
1876 - Fixed a bug which causes merpp to crash in some environments
1877
1878 - Implemented auto enabling scheme for Branches to speed up reading
1879 a lot (see MReadTree and MTask)
1880
1881 - Fixed a bug in the Histogram classes which caused histograms to
1882 be written to a file by MWriteRootFile without request
1883
1884 - changed the object I/O from the old stylish root I/O to the new
1885 'auto evolution scheme' This was done only for classes which are not
1886 yet used in Monte Carlo files, so that these files are still readable.
1887
1888 - Added support for a progress bar in MEvtLoop and MReadTree
1889 (see the Analysis Window in Mars for an example)
1890
1891 - Fixed a bug in the package creation which disturbed the conversion
1892 between a mars version unpacked from a tar file and the repository.
1893
1894 - Changed the code to writer merpped (converted into root format)
1895 raw files, to get faster (around 10%)
1896
1897
1898
1899 *** Version 0.4 (2001/09/20)
1900
1901 - This release is made to compile on a root version >= 3.00
1902
1903 - Fixed a bug which causes MReadTree to read the first file only
1904
1905 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
1906
1907 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
1908
1909 - Added a task to write several container to a root file (MWriteRootFile)
1910
1911 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
1912
1913 - Added calculation of the collection area (MMcCollectionAreaCalc)
1914
1915 - fixed some bugs in the Hillas calculation
1916
1917 - added filters to be able to control the task execution dependent on
1918 a parameter (for example: the number of level 1 triggers in a MC-file)
1919
1920
1921
1922 *** Version 0.3 (2001/04/23)
1923
1924 - Many demo macros added
1925
1926 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
1927
1928 - Hillas Calculation added
1929
1930 - Standard image cleaning available
1931
1932 - MReadTree is now able to handle more than one file
1933 (Remark: of the same structure)
1934
1935 - Now we are able to display events in a first version of the
1936 Camera event display. To do this we must run the macro
1937 "macros/readCT1.C" to read data from CT1.
1938
1939
1940
1941 *** Version 0.2 (2001/01/24)
1942
1943 - First Implementation of a Gui to read the raw data. Start the
1944 gui with the command mars.
1945
1946
1947
1948 *** Version 0.1 (2000/12/20)
1949
1950 - First official release 0.1
1951
1952 - Changes:
1953
1954 + changed calling style of MRawPixelIterator from do...while to
1955 while-loop
Note: See TracBrowser for help on using the repository browser.