source: trunk/MagicSoft/Mars/NEWS@ 8217

Last change on this file since 8217 was 8217, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 82.9 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: Website to plot values from the database has been added.
6
7 - general: The changes to the interpretation of phrases lead to
8 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
9
10 - general: Added a possibility to display grouped data in the plotdb.C
11 macro (and similar macros). This allows to plot hourly, nightly,
12 weekly, monthly and yearly averages.
13 For more details see the plotall function of the macro
14
15 - callisto: Redone the signal extraction this includes:
16 + Unified the algorithms to extract the pedestal for all pedestal
17 extractions done
18 + Unification of hi- and lo-gain into one array
19 + Unification of hi- and lo-gain extraction for Spline and
20 Digital Filter (means now exactly the same algorithm is used,
21 not a copy-and-pasted one)
22 + Store pedestal subtracted data in a common place
23 + Improved extraction algorithms. If the algorithms search a
24 maximum but don't find one they don't return the maximum anymore
25 + Improved the extraction such that a information for signal
26 and time which is consistent is returned
27 + replaced the numerical spline with a (not slower) analytical
28 solution
29 + Lowered the saturation limit from 250 to 245 to make sure that
30 we are far away in all pixels from problems with the clock-noise
31 + The start of the lo-gain extraction is calculated from the hi-gain
32 arrival time. In case of saturation an estimation is used.
33 + the hi-gain window was extended to slice 16. This allows extraction
34 of very late pulses in single pixels or of huge hadron showers.
35
36 - callisto: To gain obsolete space we do not write the
37 MPedestalFundamental anymore. Also calibration and bad pixel
38 treatment is not done for it anymore because it has never been used.
39
40 - optim: fixed a problem with the optim-macros which was due to a bug
41 in the new phrase parsing
42
43 - ganymed: To get a nice FalseSource plot (instead of the all-information
44 debug plot displayed as a standard plot) use the context menu
45 somewhere between the two upper plots, click on "DrawNicePlot"
46 and enjoy the result. (It is the same context menu which contains
47 the other options)
48 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
49
50 - sponde: now also allows the uasge of random forest
51
52 - sponde: added a plot showing the cut efficiency
53
54
55
56 *** Version 0.10.3 (2006/10/23)
57
58 - database: Implemented ObservationMode flag in websites.
59
60 - database: For sequences there is now also the stoptime available on the
61 websites.
62
63 - database: Removed ManuallyChanged flag from sequence-info websites,
64 as it is not needed anymore with the new sequence building algorithm.
65
66 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
67 Class for calculation of confidence intervals (upper limits).
68 Use model 3 or 4 for upper limit calculation for MAGIC observations.
69 Please read the class instruction of TRolke for more information.
70
71 - general: The programs now return 0xfe if the requested resource file
72 doesn't exist.
73
74 - general: Errors comming from root itself are now not output to
75 stderr anymore but to our default (colored) log-stream.
76
77 - general: Changed the interface to TFormula such that now everything
78 is parsed by TFormula, which should allow to use phrases even
79 without paranthesis correctly parsed.
80
81 - callisto: replaced the AdHoc number of effective integration slices
82 in the digital filter by an average of the correct number, averaged
83 over all possible set of weights. This also gives correct numbers
84 for the lo-gains which were totally wrong before.
85
86 - callisto: drastically reduced memory consumption by not storing
87 all intermediate calibration results in memory anymore (we might
88 write them into a file in the future)
89
90 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
91 debug plot displayed as a standard plot) use the context menu
92 somewhere between the two upper plots, click on "DrawNicePlot"
93 and enjoy the result. (It is the same context menu which contains
94 the "DrawAll" option)
95 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
96
97
98
99 *** Version 0.10.2 (2006/10/15)
100
101 - general: changed the building of the sequence files such, that
102 the source-/project name in case of wobble-sources is not the
103 source/project of the first data run anymore but the new generalized
104 wobble source/project
105
106 - general: Added some functions to MAstro to calculate sun and
107 moon properties
108
109 - general: Added two new macros (starvisday.C and starvisyear.C)
110 which allow to plot the visibility of several stars in one day
111 or of one star along one year
112
113
114
115 *** Version 0.10.1 (2006/10/11)
116
117 - general: HTML logging output was distorted... fixed.
118
119 - general: Changed the writing of the sequencefiles such that only
120 as many pedestal files as giving at least 1000 pedestal events which
121 are nearby the first calibration run are used as pedestal runs
122
123 - sponde: In the calculation of the collection area(s) and the
124 distribution for MOnte Carlo and estimated energy the error
125 calculation was wrong because root didn't take the errors
126 properly into account... fixed.
127
128
129
130 *** Version 0.10 (2006/10/10)
131
132 - general: all executables now check consistency of the root version
133 installed with the root version used for compilation. The return
134 code in this case is 255.
135
136 - general: The algorithm to build seqeunces has been redesigned
137 completly. It is now more flexible in terms of a resource file
138 resources/sequences.rc which can be used to partly overwrite
139 the default algorithm and defined the important part of the
140 algorithm. It also takes correctly into account several ways
141 of taking wobble-data. Currently the new algorithm doesn't take
142 the number of pedestal events anymore into account (so a sequence
143 could have much less than 1000 pedestal events and data runs are
144 no-more used instead)
145
146 - general: a lot of small changes to make the code compatible with
147 root 5.12/00 and gcc 4.1
148
149 - general: Fixed some warnings thrown if more warnings are switched
150 on in the compiler
151
152 - general: Added a function to MMath which returns the Median of
153 the distribution abs(y[i]-median) but at 68:32 division instead
154 of 50:50, which is somehow the median counterpart of the rms.
155
156 - general: MAstroCatalog allows now to read calatog files (as bsc5)
157 even if they are compressed with gzip (recommended compression
158 is with "-1")
159
160 - showplot:
161 + batch mode creation of image files now works with root 5.12/00
162 + added support for writing bmp (though it never produces
163 bmp which can be read by programs like xv or gimp)
164 + added support for xml
165 + added new option to start the display with a different size, by
166 --display-width=nnn or --display-height=nnn
167 + added options to define the canvas size when the display is started
168 --canvas-width=nnn or --canvas-height=nnn
169 the option can also be used for batch-mode conversion
170 + added an option which automatically fits the display size to the
171 desktop-size: --auto-size
172
173 - merpp: didn't recognize files with the extension .raw.gz - fixed.
174
175 - merpp: allow the reports to have 1000ms due to a bug in the camera
176 program.
177
178 - callisto: New swapped pixels have been found and corrected. For
179 details see MRawRunHeader::FixAssignment()
180
181 - callisto: Callisto now raises an error if one of the input files could
182 not be opened.
183
184 - callisto: In some rare cases it could happen that in the signal
185 extraction of the digital filter the extractor returned nonsense
186 results due a wrong initializion of a variable (this happens in
187 cases in which the extracted signal is exactly zero or the
188 digital filter couldn't slide because of a too small extraction
189 window, which could happen in the lo-gain extraction)
190
191 - callisto: The lo-gains have been marked as valid in some cases
192 when they got not extracted at all (deltsumlo=deltatimelo=0) because
193 the allowed extraction range (fLoGainLast-fLoGainFirst) was
194 smaller than the number of slices (fLoGainWindowSize) needed
195 by the lo-gain extractor
196
197 - callisto: Updated absolute calibration constants (muon calibration)
198
199 - callisto: fixed a bug which caused the hi-gain saturation not
200 to be handled properly in the spline (the position of the
201 saturation was calculated incorrectly)
202
203 - callisto: fixed a bug which gave weird results if hi- _and_
204 lo-gain could not be extracted properly. In some cases hi-
205 and lo-gain have not been extracted at all and the random result
206 got calibrated. In other cases the hi-gain was saturating and the
207 lo-gain has not been extracted. For this a completly arbitraty
208 scale factor was applied to the result from extracting the
209 charge of the saturating hi-gain.
210
211 - callisto: improves handling of extracted signal if lo- and/or
212 hi-gain could not be extracted properly. If no appropriate
213 calibration of either the signal or the arrival time is possible
214 the pixel is now markes as unsuitable instead of estimated.
215
216 - callisto: Fixed a problem in the spline extraction which gave
217 weird results if the signal was extracted from the first (and
218 highest) slice (as a workaround extraction from the first
219 slice has been forbidden)
220
221 - callisto: Fixed a bug regarding the use of the QE which doesn't
222 effect the result because the default is used anyhow.
223 (The bug was there since 14/07/2005)
224
225 - callisto: Changed the default for fgLoGainStartShift to -2.4
226
227 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
228 factors to be always 10 for all pixels as soon as the first
229 calibration update has happend.
230
231 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
232 was off by more than one slice (which gives wrong values for
233 pixels which have saturated the hi-gain) This was a problem
234 mainly for timing studies, not so much for the automatic standard
235 analysis. Also the values for the Spline have been changed slightly:
236 + Digital Filter from 1.70 to 0.95
237 + Spline from 1.39 to 1.30
238 The numbers were sorted out by an extensive test in the
239 test-database.
240
241 - callisto: Removed the tab showing the average calibrated arrival
242 time. It never gave useful information.
243
244 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
245 lo-gain pulse for data pulses if hi- and lo-gain have saturated
246 and both were extracted because the hi-gain was above the
247 LoGainSwitch.
248
249 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
250 lo-gain pulse position (after application of LoGainOffset, which
251 means in the ideal case it is 0) for data pulses if hi- and lo-gain
252 have saturated and both were extracted because the hi-gain was above
253 the LoGainSwitch.
254
255 - callisto: After extensive tests a new threshold level for determination
256 of the pulse position has been found at 50phe. This is due to the
257 fact that for lower pulses the arrival time changes its average
258 behaviour dramatically. It tends to the average of the extraction
259 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
260
261 - callisto: Added two more plots to the calibration part. The average
262 extracted signal and the average extracted arrival time as
263 extracted by the signal extractor (This can help debugging problems
264 because it doesn't involve a fit)
265
266 - star: changed the fit for the effective on time such that initial
267 values are calculated automatically now instead of using build
268 in values. This makes the fit more indepedant of the underlaying
269 rates. With a test of ~350 sequences in the test database it could
270 be shown that the new fit gives the same result +/-1sek.
271 The highest deviation was +5s the lowest -10s. You can now control
272 the bahaviour with two resource values:
273 MHEffectiveOnTime.FistBin: 3
274 MHEffectiveOnTime.NumEvents: 12000
275 Use FirstBin=1 and NumEvents=120 to fit the effective on time
276 from the resulting gamma candidates
277
278 - star: The Center histogram in MHHillas is now by default displayed
279 with the colz draw-option
280
281 - ganymed: now produces valid error codes if failed
282
283 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
284 with the option "hadronness" instead of "area" or "both" if
285 you want to use both cuts. The hadronness cut includes a fixed
286 cut in hadronness (index 8) and a fixed cut in size (index 9).
287
288 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
289 the M3Long of the anti source to be not properly evaluated
290 (actually is was evaluated as a unique random number) in case
291 of optimization with anti-theta cut switched on. This might have
292 lead to improper, but not necessarily wrong, optimization results.
293
294 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
295 how to use random forest
296
297 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
298 ganymed_onoff.rc. Seems to be unintentional that they were different.
299
300 - sponde: Since the introduction of the possibility to define a
301 normalization energy instead of using the integral the default
302 was not using the integral anymore but a normalization energy of
303 1GeV. It is now the integral again.
304
305 - sponde: Fixed a problem in the weighting which did not allow
306 a MC slope of -1.
307
308
309
310 *** Version 0.9.6 (2006/05/24)
311
312 - general: changed the binning of the azimuthal profile of the camera
313 such that it is aligned with the 60deg boundaries.
314
315 - merpp: better handling of problems with the TH, TD part of the
316 CC-REPORT for files older than 200507190 and 200412210
317 respectively
318
319 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
320
321 - merpp: implementd latest changes in starguider reports (sinc 9th May)
322
323 - callisto: if an arrival time is extracted outside the fadc range is
324 was set to the boundary before. Now a random number is assigned
325 instead to avoid unfortunate coincidences of arrival times just
326 by this arbitrary value.
327
328 - callisto: added a new option to callisto.rc which allows
329 to set the maximum arrival time difference allowed for the
330 badpixel algorithm to determin whether a pixels belongs to a shower:
331 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
332
333 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
334 to 0.9 as suggested by Stefan due to a recent study on the fraction
335 of pixels surviving the image cleaning
336
337 - callisto: switched off error in case of "pulse is too much to the left"
338
339 - callisto: The extraction window is not adapted anymore. This means that
340 the pulse is extracted from the full range. The draw-back is that the
341 background (pedestal) will become slightly higher. Switching on/off
342 the PulsePosCheck in the callisto.rc only effects filling the
343 histograms.
344 WARNING: If the pulse is too much to the left data is calibrated!
345 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
346 in the database to make sure that your data is valid!
347
348 - star: Show also the number of stars correlated correctly by the
349 starguider
350
351 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
352 than one off-source region in wobble-mode. To use it add the following to
353 your ganymed_wobble.rc:
354 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
355 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
356 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
357 + Cut1.ThetaCut: None
358 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
359
360 - ganymed: in the case the latest report is older than a default (currently
361 one minute) and the current report will be skip the starguider
362 correction and calibration will be reset. The maximum age can be
363 setup from ganymed.rc by (minutes):
364 MPointingDevCalc.MaxAge: 1.5
365
366 - ganymed: A first implementation showing all size-bins for the theta-sq
367 resp. alpha-plots in a single tab automatically
368
369
370
371 *** Version 0.9.5.1 (2006/05/05)
372
373 - general: Added a new option "zdiff" to the Makefile which runs
374 "cvs diff" as "make diff" would do, but with compression
375
376 - general: accelerated MTFillMatrix (used for eample in all training
377 and optimization macros) by skipping some obsolete calles in the
378 eventloop the first and second loop could be accelerated by ~20%
379
380 - general: Added a missing feature in the MFilterList class which
381 prevented MFEnergySlope from working correctly in trainenergy.C
382
383 - general: Accelerated the random forest training and usage a bit
384
385 - merpp: Adapted to new raw data file format version 6
386
387 - merpp: fixed a problem with reading the starguider reports
388 after 6.3.2006
389
390 - callisto: At some times six pixels had to be exchanged manually in the
391 data. If the pixels to be swaped are both not found, an error was raised
392 and calibration was stopped. Now it is assumed they are intentially not
393 mapped and the Error has been changed to a Warning.
394
395 - star: Added new image cleaning based on the arrival time of the shower.
396 The new cleaning can be accessed using the parameter "Time" instead of
397 the the old one (like "Absolute) in the star.rc-file.
398 Recommended parameters:
399 + MImgCleanStd.CleanLevel1: 8.2
400 + MImgCleanStd.CleanLevel2: 5
401 + MImgCleanStd.CleanRings: 2
402 + MImgCleanStd.KeepSinglePixels: No
403
404 - star: Simplified the calculation of the effective on time. By letting
405 the fit start in the third bin the result should become more stable.
406 The fit quality is now ignored for the theta-plot which is not used
407 in the analysis later. Still better pre-cut which, for example,
408 remove events triggered by car-light (rate changing on a short
409 time-scale) are missing.
410
411 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
412 for optimization (kWeakSource) which is suggested by the Berlin
413 people for weak sources.
414
415 - macros: plotdb.C:
416 + if no dataset and no time-interval is given only sequences with
417 an effective on-time above five minutes are plotted anymore
418 + added a new tab "RelTime" displaying the relative on-time
419 (effective on-time divided by the observation time)
420
421 - macros: optim*.C: by skipping some obsolete calles in the eventloop
422 the optimization became a lot faster
423
424 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
425 To display them just delete the pads displayed on top.
426
427 - ganymed: fixed a bug which could cause strange behaviour in wobble
428 mode if no starguider information was available due to an incorrect
429 initialization of the starguider calibration
430
431 - ganymed: The scale region in the False Source Plot (MHDisp) can now
432 be changed from within the plot. It can also be setup from the
433 resource file using:
434 + MHDisp.fScaleMin: 0.325
435 + MHDisp.fScaleMax: 0.475
436
437 - ganymed, showplot: Fixed a problem with the fit to the off-data
438 (HistOff) which could cause a time lag or an inifinite loop.
439 The bug did not effect the results at all.
440
441 - sponde: Added a new tab showing the effective collection area after
442 trigger (including the software trigger)
443
444 - sponde: MMcSpectrumWeight has a new option which allows to define
445 the scaling factor not by the integral of the events but at
446 a defined energy:
447 e.g. MMcSpectrumWeight.NormEnergy: 200
448
449 - MTFillMatrix, sponde: by skipping some obsolete calles in the
450 eventloops the loop could be accelerated by ~20%
451
452
453
454 *** Version 0.9.5 (2006/03/13)
455
456 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
457 and added the standard Disp-parametrization
458
459 - macros: added a new macro datacenter/macros/plotstat.C allowing
460 to plot statistics about the data processing
461
462 - macros: added a new macro to plot the muon correction coefficients
463 versus period (macros/plot/mucal.C)
464
465 - showplot: path inflation for ganymed files was broken
466
467 - callisto: Fixed an important bug. When the number of saturating pixels
468 were calculated the bad pixel information already available from the
469 calibration was ignored. This yields wrong values in case pixels
470 are broken and saturate all the time or randomly.
471
472 - callisto: Updated Muon calibration constants. Spline data now also uses
473 different values for different periods
474
475 - star: The time-evolution shown in the effective on-time plot now displays
476 the axis range (if there are no holes it should be similar to the
477 effective on-time)
478
479 - star: Added two new image parameters:
480 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
481 the three pixels next to the center of gravity and the size
482 + MNewImagePar.fConcCore: The ratio of the signals of all
483 pixels inside or touching the ellipse and the size
484
485 - ganymed: now stops in requested source isn't found in catalog file
486
487 - ganymed: Many improvements to the phi-plot in wobble mode:
488 + with a template the ideal background is displayed
489 + a possible camera inhomogeneity is taken into account
490 + the anti theta cut is better supported
491 + the phi cut is automatically calculated from the theta cut
492 See the examples in ganymed_wobble.rc for more details.
493
494 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
495 times the bin-width instead of the absolute energy
496
497 - ganymed: New cuts for on/off and wobble mode
498
499 - ganymed: The smearing of the False Source plot has been increased
500 to 0.06
501
502 - ganymed: The starguider calibration can now be changed from the
503 resource file.
504 See the examples in ganymed*.rc for more details.
505
506 - ganymed: added a new option for on-/off-observations
507 MJCut.RandomSourcePosition
508 If switched on the distribution of observation time of the source
509 position in the camera is calculated from the on-data and randomly
510 applied with this distrbution to the off-data.
511
512 - ganymed: by skipping some obsolete calles in the eventloop the
513 first and second loop could be accelerated by ~20%
514
515 - ganymed: The default in ganymed_onoff.rc is now to determin the source
516 position in the off-data randomly according to its distribution in the
517 on-data.
518
519
520
521 *** Version 0.9.4.3 (2006/02/13)
522
523 - general: Fixed a bug in most of the programs which prevented the
524 compile date in the startup message to be displayed
525
526 - general: Simplified program calls. The following abbreviations
527 are now possible:
528 showlog callisto 55599
529 showplot signal 55599
530 star 55599
531 callisto 55999
532 ganymed 2
533 In this cases the corrsponding root-, log-, sequence- or dataset-
534 filename is automatically compiled using the default datacenter
535 paths ("/magic/*")
536
537 - general: Fixed a long outstanding bug which made axis tick marks
538 disappear if MDataFormula was used (eg. abs(x))
539
540 - general: Updated MMath with new functions to calculate the results of
541 a exponential, logarithmic and powerlaw fits analytically.
542
543 - general: Updated some macros with comments:
544 + macros/optim/optimdisp.C
545 + macros/optim/optimenergy.C
546 + macros/optim/optimwobble.C:
547
548 - general: MTFillMatrix (the class to fill one or two MHMatrix from
549 files) now allows adding a pre-cut like in the optimization. E.g. this
550 is useful to perform g/h-separation cuts before training the random
551 forest.
552
553 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
554 correctly assigned in the raw data assignement table. A fix to correct
555 the assignment tabel have been implemented.
556
557 - general: MAstroCatalog now allows rotating of the sky-grid and stars
558 by 90, 180 and 270 deg.
559
560 - general: the macro plotdb.C now allows to highlight sequences belonging
561 to a datset. For more details see the descritions in the macro.
562
563 - StatusDisplay: Fixed the algorithm to calculate the size ratio
564 of the display, it gave wrong results espacially for big sizes.
565 Now the embedded canvas should always have a ratio width/height=3/2.
566 The "Size" options have been updated with values fitting the 3/2
567 size ratio.
568
569 - RanForest:
570 + Updated the random forest classes to support also the
571 regression method implemented by Thomas H.
572 + added new tutorial macro how to train the random forest
573 for energy estimation (macros/optim/rfenergyest.C)
574 + new classes to train the random forest (still in development)
575 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
576 + new tutorial macros for random forest training in macros/train
577 trainenergy.C, traindisp.C, trainseparation.C
578
579 - mars: now allows to setup a cut in the resource file mars.rc to choose
580 the events to be displayed, eg:
581 Cut.Condition: {0} && {1}
582 Cut.0: MHillas.fSize>100
583 Cut.1: MHillas.fSize<900
584
585 - merpp: Made aware of the new .rep format 200510250. This includes
586 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
587 the discriminator thresholds (MCameraTD) and the disciminator
588 delays (MCameraTD). All of them come with the CC report and are therefor
589 written to the CC tree.
590
591 - callisto: fixed a bug in the calculation of the arrival times in
592 the Digital Filter. They were all shifted by the same amount
593 fHiGainFirst. This caused an offset in the order of the position of
594 the left border of the extraction window in the times calculated
595 from high-gain and from low-gain. The bug effected only the absolute
596 arrival times. The bug was there since 30.1.2005.
597
598 - callisto: Changed the ExtractionWindow for the pulse position check
599 such that the camera inhomogeneity becomes as less as possible and
600 comparable to the pulso position check switched off. More details
601 on the study will be given at our result web-page.
602
603 - ganymed: ganymed.rc, ganymed_onoff.rc:
604 changed to new cuts trained with 1ES1218 and Crab-data
605 for maximum sigma*log10(excess)
606
607 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
608 a new option was implemented to estimate Disp (CalcDisp)
609
610 - ganymed: Implemented two new options which allow
611 to overwrite the default path to search for the sequence files
612 --ins=/magic/sequences
613 and where to search for the image data
614 --ind=/magic/data/star
615
616 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
617 dx/dy from the resource file by
618 MSrcPosCorrect.Dx
619 MSrcPosCorrect.Dy
620
621 - ganymed: fixed reading the source catalog. Only as many chars
622 as the requested source name had were compared (If a source
623 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
624 were requested it could happen that the coordinates of
625 "1ES1218" were read) The source coordinates are now printed
626 in addition to its name to the logging output.
627
628 - ganymed: changed the background fit in the case of a ThetaSq function
629 from a polynomial to a exponential, this should give a big improvement
630 for on-only analysis'
631
632 - ganymed/sponde: Calculation of the error of single size-/energy-
633 bins now uses Li/Ma (5) instead of LiMa (17)
634
635 - sponde: Added a plot E^2*dN/dE
636
637 - sponde: The energy estimator plot should now show values like
638 they are commonly used.
639
640 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
641 (a powerlaw with cutoff didn't work before)
642
643
644
645 *** Version 0.9.4.2 (2005/10/01)
646
647 - general: added new tutorial macro macros/tutorials/threshold.C:
648 how to calculate the threshold
649
650 - general: added a new game. Start it from the interpreter with
651 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
652 and MagicReversi)
653
654 - general: neighbor pixels in MGeoms are now sorted clockwise
655
656 - merpp: made aware of new format 20050829-0
657
658 - callisto: New scale factors from muon analysis, stored in new
659 resource file resources/calibration.rc
660
661 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
662 the eventloop if something went wrong. This is necessary for the
663 automatic processing
664
665 - callisto: Implemented a new treatment for the time information
666 developed by S.Ruegamer, this should give much better response than
667 the old very primitive algorithm. This is especially important
668 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
669 treatment was buggy! As neighbor pixels to interpolate the
670 arrival times always the pixels 0 to 5 were taken)
671
672 - callisto: In addition to the new treatment of arrival times the
673 decision of the treatment whether a pixel contains shower
674 information or not is used to improve the signal interpolation
675 further. Previously interpolated pixels showed a non-zero signal
676 do the peak searching signal extractors. Having a signal pixel
677 beside raised the signal above the cleaning level. Thus the
678 pixel survived cleaning to often but with a too low mean signal.
679 By replacing empty pixels with a gaus (mean and rms from the
680 corresponding Area entries in MPedPhotCam) this effect can
681 be supressed.
682
683 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
684 got lost when the events were stored by the calibration... fixed.
685 (This was no problem for normal image cleaning because the pixel
686 content was artificially set to 0 not surviving standard cleaning
687 algorithm)
688
689 - callisto: Fixed a bug which caused the random and peak-search pedestal
690 extracted with an extractor to be exchanged for the first (roughly)
691 500 events (*Extractor and *ExtractorRndm).
692 (They were simply exchanged in callisto.cc) This bug might have been
693 introduced in Mars 0.9.4 when the order of calculation of the two
694 types of pedestal in callisto got exchanged. The bug only effects
695 the first seconds of data of each sequence.
696
697 - star: Taking the arrival time of Muons into account the calculation
698 of the parameters could be made independant of the noise
699 (pedestal rms). The dependance was due to the bias of the peak search
700 extractor. Now only a ZA dependamcy is left which is not yet fully
701 understood.
702
703 - ganymed: The sequences were still not sorted correctly in any case,
704 because they were sorted by the full qualified path name. Now they
705 are sorted by their sequence number.
706
707 - ganymed: new values for the spark-event-cut
708
709 - sponde: required missing MEnergyEst from ganymed.root... fixed.
710
711
712
713 *** Version 0.9.4.1 (2005/08/18)
714
715 - callisto: fixed some problems with the calibration in case of
716 inteleaved events. Therefor the final and some intermediate
717 fits are skipped which would take place on partly filled #
718 histograms and gave wrong results or failed completely.
719
720 - callisto: If the intermediate finalization of the histograms
721 calculating the mean charge of the calibration signal fails
722 it is counted now and printed in PostProcess of MCalibCalcFromPast.
723
724 - ganymed: Fixed some bugs which caused problems in On-only mode.
725 Still the false source plot doesn't give reasonable results.
726
727
728
729 *** Version 0.9.4 (2005/08/05)
730
731 - general: Fixed the ZA binning. It did not correctly fit the
732 MC binning
733
734 - general: Added a class to correct for the missfocussing in
735 April (MSrcPosCorrect)
736
737 - general: Random Forest energy estimator should now work properly
738
739 - general: MHCamera now displays the profiles in deg instead of mm
740
741 - general: MH::SetPalette offers a lot of new palettes
742
743 - general: MHillas - the case of CorrXY==0 is now handled properly
744
745 - general: implemented the possibility to change the line and
746 marker style of a sky-grid drawn by MAstroCatalog
747
748 - general: Runs in sequences and datasets are now automatically
749 ordered (it is assumed that the order of their filenames correctly
750 represents the order of observations) to ensure correct reading
751 of the subsystem data
752
753 - general: Runs cannot be added to a sequence twice anymore. Also
754 Sequences cannot be added twice anymore to a dataset.
755
756 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
757 It gave wrong results by 1./2pi
758
759 - showplot: got a new option to start a root interpreter, too
760
761 - mars: now displays a rough estimate of Disp and the third moment
762
763 - mars: now displays the event time MTime if available
764
765 - mars: show muon parameters graphically
766
767 - mars: now the file to open can be given as commandline
768 argument
769
770 - merpp: Added support for new arehucas version >= 200507190
771 implementing values for three temperature sensors in the
772 counting house (MCameraAUX) and the name of the HV settings file
773 (MCameraHV).
774
775 - merrp: Also fixed some problems with wrong versions numbers stated
776 by arehucas and implemented some fixed for old versions (<200407070)
777
778 - callisto: MCalibrationHiLoCam can now be printed from its context
779 menu, eg in the TBrowser
780
781 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
782 - 1.39 (MExtractTimeAndChargeSpline)
783 - 1.40 (MExtractTimeAndChargeDigitalFilter)
784 This is important mainly for timing studies.
785
786 - callisto: Changed limits in MHCalibrationChargeCalc from
787 - -100.125 to -98 (fgChargeHiGainFirst)
788 - 1899.875 to 1902. (fgChargeHiGainLast)
789 - -100.25 to -99 (fgChargeLoGainFirst)
790 - 899.75 to 901. (fgChargeLoGainLast)
791 Introduced new limits:
792 - fgNumLoGainBlackoutLimit: 0.05
793 - fgLoGainBlackoutLimit: 3.5
794 - fgLoGainPickupLimit: 3.5
795
796 - callisto: The handling of automatic weights for the digital filter
797 has been improved. There are now new calibration weights special
798 for Monte Carlo calibrations.
799
800 - callisto: Updated Muon scale with latest results (1% difference
801 for most data, 5% for Mar/Apr'05)
802
803 - callisto: use a new criterium to exclude bad pixels: If the high-gain
804 was saturated and the blackout-events in the low-gain exceed the
805 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
806 This excludes those pixels which have a saturating high-gain
807 channel, but the low-gain switch does not switch often enough
808 to make the distribution reliable.
809
810 - callisto: fix a bug counting the number of saturated events. Up to now,
811 the number of saturated slices was counted (which is one for a not too
812 high number), but for some (pathological) pixels, many more slices
813 saturated and produced wrong limits.
814
815 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
816 + MCalibrationRelTimeCam.CheckFitResults: Yes
817 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
818 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
819 + MCalibrationRelTimeCam.CheckOscillations: Yes
820
821 - callisto: introduce max. number of events for intercalibration,
822 the rest gets skipped. Default: 4096
823 The calibration causes too many un-reliable pixels if more
824 than about 5000 events are treated (@500 Hz) because of the
825 mode hopping of the VCSels. However, in the past, some
826 calibration runs have been taken (erroneously) with more
827 than 5000 events, especially the intensity scans where
828 a good precision is needed.
829
830 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
831 photo-electrons for the spline extractor by 1-2% (correctly).
832
833 - callisto: The intercalibration is now done using a full f-factor
834 method instead of a simple update. This makes things slower but
835 more reliable in terms of gain-fluctuations and sudden VCSEL gain
836 changes.
837
838 - callisto: MPedestalY3 now uses the same extraction range as the data
839 as calculated by MPedestalY2
840
841 - callisto: A check of the fraction of allowed unsuitable (10%) and
842 unreliable (30%) pixels has been addded when the conversion is
843 calculated from interleaved events
844
845 - star: fixed a bug which caused MEffectiveOnTime containers not to
846 be written. In the worst case they were skipped almost all, in the
847 best case they were all ok. It depends on how often the new value
848 was assigned just with an event which was skipped later by another
849 task
850
851 - star: new histograms MHPointing and MHRate
852
853 - star: New tab (Currents) displaying the time evolution of the mean
854 DC currents
855
856 - star: New tab (MeanRms) displaying the time volution of the mean
857 Pedestal Rms
858
859 - star: Output now contains MReportStarguider
860
861 - star: Improved muon analysis. Due to the absense of a constant
862 for the gaus fit for arc width and the fact that the arcwidth
863 plot was a histogram instead of a profile the resulting psf
864 became pedestal rms dependant
865
866 - ganymed: added new plot (MHPhi) for wobble mode as described in
867 http://www.astro.uni-wuerzburg.de/results/ringmethod/
868
869 - ganymed: corrects now (correctly?) for the misspointing in
870 May/April 05
871
872 - ganymed: Two new default templates for ganymed.rc are avilable:
873 ganymed_onoff.rc and ganymed_wobble.rc
874
875 - ganymed: The first version of MFMagicCuts has been released
876
877 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
878
879 - ganymed, sponde: There are two new options to determin the number
880 of bins for the signal region (NumBinsSignal) and the number of
881 total bins (NumBinsTotal) in the MHThetaSq histogram
882
883 - ganymed: optimized palettes for MHDisp
884
885 - ganymed: Fixed an important bug when using ThetaSq as fit function:
886 The result for the sigma of the gauss(sqrt(x)) fit was a factor
887 sqrt(2) to large
888
889 - ganymed: The false source plot (MHDisp) is now based on Disp
890 and a background model determined in the first loop is
891 subtracted
892
893 - ganymed: MFMagicCuts are now available in the cvs. The correct
894 solution for the disp ambiguity problem is now calculated using
895 the third moment. The third moment cut therefor is skipped.
896
897 - ganymed: Output now contains "Disp [MParameterD]" which sign is
898 already determined by the third moment along the major axis and
899 so its actual sign is aligned along the major axis of the shower.
900
901 - ganymed: If starguider data is available it is taken into account
902 when calculating the source position. This is especially important
903 for wobble data at high zenith angles and culmination data.
904
905 - ganymed: If available the starguider data is taken into account as
906 good as it is possible without a starguider calibration. To switch
907 it off add
908 MPointingDevCalc.MaxAbsDev: -1
909 to your ganymed.rc
910
911 - sponde: the zenith angle distribution is now weighted instead of
912 choosen by default. This gurantees higher statistics in the highest
913 and lowest energy bins. To switch this behaviour off use...
914
915 - sponde: now automatically displays the energy threshold
916
917
918
919 *** Version 0.9.3 (2005/06/03)
920
921 - general: MMcEvt now derived from MMcEvtBasic which should
922 have no influence on compatibility with older camera files
923
924 - general: Implemented a new option to MReadReports which allows
925 to force reading of the first event of some trees (eg. Drive-tree)
926 before any other tree.
927
928 - general: Made a fix to MPointingPosCalc which assumes that the
929 run-type is real-data if Process is called before ReInit, such
930 that also the very first Drive-events in a run are treated
931 correctly.
932
933 - shoplot now displays the filename in the title bar of the window
934
935 - merpp: new options: --auto-time-start --auto-time-stop which
936 allow to cut updating with slow-control at the start- or
937 (previousle --auto-time only allowed: and) stop-time of
938 the run stored in the runheader.
939
940 - callisto: changed default of fgFallTimeHiGain in
941 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
942 already set as default in callisto_Dec04Jan05.rc
943
944 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
945 now changes the filename for new weights automatically for
946 cosmics, MC and for different calibration colors.
947
948 - callisto: a problem with the order of some code cause the
949 name of the weights file in MPedestalY2 to be ignored.
950 Wrongly the calibration_UV weights were used instead
951 of the cosmics weights set in callisto.rc.
952
953 - callisto: should allow ct1 pulser data when the color is
954 explicitly set also for pretty new runs
955
956 - callisto: a new option (MCalibrateData.ScaleFactor) allows
957 to introduce an additional scale factor (should be around 1)
958 to adapt for slight deviations in different extractors from
959 the MC calibration. For MC calibrations the scale factor
960 is fixed to 1
961
962 - callisto: MFCosmics should handle very high signals a bit
963 more accurate now
964
965 - callisto: when calculating the mean pedestal rms for different
966 pixel sizes or sectors also kUnsuitableEvt is now taken into
967 account - not only kUnsuitableRun
968
969 - callisto: '-raw' option is now the default
970
971 - callisto: A dead pixel check has been implemented in MJPedestalC2.
972 This has the advantage that mean values in the calibration (eg
973 arrival times) are calculated more accuratly.
974
975 - callisto: In the resource file callisto_Dec04Jan05.rc
976 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
977
978 - callisto: new Hi-/Lo-Gain intercalibration constants
979 hilocalib_sp1.root and hilocalib_sp1_mc.root
980
981 - callisto: changed default for MJPedestalY2.MaxEvents
982 from 2000 to 5000 like in callisto_Dec04Jan05.txt
983
984 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
985 has changed from 9.0 to 6.0. This is necessary to exclude two very
986 ringing pixels in September which - when kept - destroy the image
987 cleaning around them (Markus G.)
988
989 - callisto: (!) The Muon analysis of all data taken so far has
990 suggested that different extractors give slightly different
991 absolute results after calibration, due to there different
992 handling of the calibration- and cosmics pulse shape. Although
993 the over all calibration seems to be a bit to pesimistic (or
994 the MC seems to be a little bit - 3-5% - too much attenuated).
995 There for correction factors have been introduced which correct
996 the calibration constants by
997 0.956937799 for Digital Filter (callisto.rc)
998 and
999 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1000 calibration. The main advantage is, that both data types can
1001 be easily analysed together and compared to the same MC sample.
1002 The factors are choosen such, that the reference is now a
1003 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1004
1005 - star: fixed a bug which caused the first bin of the histograms
1006 vs time to disapear in PostProcess. This gave wrong results
1007 on the screen. The output and all following programs not
1008 directly accessing the histograms haven't been affected
1009
1010 - star, ganymed: Made sure that always the first Drive-tree event
1011 is read and Processed before the first data event was read.
1012
1013 - ganymed: implemented the possibility to replace the standard
1014 false source plot with a different one. For example: If
1015 you want to use a Disp based FS plot use the resource:
1016 NameHistFS: MHDisp
1017 For details about the requirements of these plots look
1018 at the corresponding classes
1019
1020 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1021 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1022 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1023 case MAlphaFitter is setup correctly. For On-Only optimization
1024 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1025 RunOn() instead of Run(). For energy estimation MJOptimize
1026 has been replaced by MJOptimizeEnergy
1027
1028 - sponde: The input MC spectrum can now be weighted to fake a
1029 different spectrum. This is done via MMcSpectrumWeight. For
1030 more details see the class description and sponde.rc
1031
1032 - sponde: The paremeter comparsion plots are not scaled by
1033 their entries anymore. Instead the MC plot is scaled by using
1034 the result spectrum of the analysis. If the input MC spectrum
1035 and the result spectrum has different slopes the absolut
1036 normalization is normally wrong.
1037
1038
1039
1040 *** Version 0.9.2 (2005/05/20)
1041
1042 - general: Changed the default paths for calibrated data and image
1043 files. (The implemented access to these files doesn't yet exist)
1044
1045 - general: support for MRunIter has been removed from the job classes
1046 (use the setter functions of MSeqeunce instead)
1047
1048 - general: ProcessFile has been renamed to Process in all job classes,
1049 because ProcessFile is missleading
1050
1051 - general: The storage of the palette in MHCamera is now possible
1052
1053 - general: new bits describing unsuitable and unreliable pixels have
1054 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1055 kDeadPedestalRms, kFluctuatingArrivalTimes
1056
1057 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1058 versions newer than V200404070
1059
1060 - general: support for cc file versions newer than V200504130. Added
1061 support for active loads (MCameraActiveLoad) and central pixel
1062 (MCameraCentralPixel)
1063
1064 - general: added new histograms for image parameters versus size
1065 (MHVsSize)
1066
1067 - general: The eventloop now automatically calls PrintStatistics
1068
1069 - Status Display: Improved support for printing:
1070 + A default can now be set in .rootrc (for more details see
1071 MStatusDisplay::PrintPS)
1072 + A print dialog is opened so that printer and command line
1073 can be canged
1074
1075 - showlog: improved such that it handles different verbosity levels
1076 more accurate now. This mean you can suppress output when
1077 using showlog.
1078
1079 - showplot: improved
1080 + The new graphics formats have been implemented
1081 (pdf, svg, png, jpg and xpm)
1082 + Implemented an interface for printing. Because you can change
1083 the printing command from the command line you can use all
1084 the nice postscript tool. To print a booklet for example call:
1085 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1086 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1087 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1088
1089 - callisto: fixed a bug in the recognition of the calibration bit
1090 pattern. Concerns only intensity calibration. (The strength of the
1091 intensity has been updated in some cases)
1092
1093 - callisto: add a filter against PIN Diode events when running over
1094 calibration runs since some of the recent calibration runs have
1095 been taken with Pin Diode.
1096
1097 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1098 39943, 44833 in the calibration (MCalibColorSet)
1099
1100 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1101 been set to 1e-18 in callisto_Dec04_Jan05.rc
1102
1103 - callisto: in callisto_Dec04Jan05.rc: set value for
1104 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1105 statistics for the calculation of the mean pulse time
1106 of the cosmisc
1107
1108 - callisto: the charge limit in the calibration has been raised
1109 from 2.5 to 4.5
1110
1111 - callisto: new setup read from callisto.rc
1112 + MCalibCalcFromPast.fNumEventsDump
1113 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1114 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1115
1116 - callisto: MExtractTimeAndChargeSpline extractor:
1117 + The integration ranges were shifted by 0.2 FADC slices to the right.
1118 + unreliable handling of floating point values caused different
1119 results on different platform or with different compiler options:
1120 The new algorithm is numerically exact and more accurate because
1121 it doesn't calculate the integration position by multiple times
1122 adding the step-size (which results in numerical uncertanties
1123 exspecially if multiplied with large numbers)
1124 + A lot of fixes have been introduced which effects integrating the
1125 spline at the edges of the valid range. In this case any memory
1126 was randomly accessed. This behaviour can be tested replacing
1127 all MArrayF by TArrayF which perform a range check (but of course
1128 they are a lot slower)
1129 ! No result obtained with the Spline before can be trusted! Due to
1130 random memory access it might by completely random!
1131
1132 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1133 + extraction range in the high gain to 4.
1134 + weights file to cosmics_weights46.dat
1135
1136 - callisto:
1137 + introduce the check for fluctuating arrival times.
1138 + set charge limit to from 2.5 to 4.5
1139 + introduce asymmetric exclusion due to "deviating number of phes":
1140 Default: -9.0 +4.5
1141 + make deviating number of phes unsuitable (see David's findings).
1142
1143 - callisto: fixed the display of unsuitable pixels. The old change
1144 to a real profile in MHCamera broke it.
1145
1146 - callisto: The cosmics filter is used in MJCalibration now
1147 independant of the pulser color (formaly it was used only for
1148 CT1-pulser data). The threshold of number of max empty pixels
1149 has been raised from 2% to 5% in MJCalibration. The maximum
1150 fraction of rejected event is 50% otherwise the calibration has
1151 failed. The filter now ignores unsuitable pixels.
1152 Setup the filter from callisto.rc using "ContCosmics"
1153 (see MFCosmics::ReadEnv)
1154
1155 - callisto: changed default for fgOffsetFromLogain back
1156 from -2.8 to -1.8 in digital filter.
1157
1158 - callisto: for the common extractors
1159 + MExtractFixedWindow
1160 * MExtractTimeAndChargeSlidingWindow
1161 * MExtractTimeAndChargeSpline
1162 * MExtractTimeAndChargeDigitalFilter
1163 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1164 and fResolutionPerPheLoGain
1165
1166 - callisto: Updated the hi-/lo-gain intercalibration constants
1167 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1168 hilocalib_df6.root
1169
1170 - callisto: The default lo-gain extraction window for the
1171 MExtractTimeAndChargeSlidingWindow extractor has been increased
1172 from 6 to 8 to take the stretch of the pusle into account
1173
1174 - callisto (!!!): fixed an important bug in the setting of the
1175 incoming pedestal pointer to the signal extractor extracting
1176 pedestals. This bug caused the pedestals not to be subtracted
1177 correctly in the calibration afterwards. The effect was about 10%
1178 too high conversion factors for the digital filter and the spline
1179 and more than 40% for the sliding window.
1180 The bug existed since end of February! (Markus G.)
1181
1182 - star: added muon support to star. A new tab "MHMuonPar" is
1183 displayed. The lower right plot is an estimate of the point spread
1184 function. A reference value is displayed. To get the real PSF
1185 you must compare with MC. The setup for the muon analysis
1186 is done in star.rc. More informations can be found in
1187 MHSingleMuon and MHCalibParCalc
1188
1189 - star: The weather data is now displayed in star
1190
1191 - star: MEventRateCalc handles the calculation of the event rate more
1192 accurate now in case of the start of a new run inside a sequence
1193
1194 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1195 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1196 changed only minimally
1197
1198 - ganymed: (MJCut and MJOptimize) now displayes the number of
1199 excess events versus size. The energy estimation is done in
1200 MJSpectrum (sponde)
1201
1202 - ganymed: got support for using other variables than Alpha, eg. Theta.
1203 Therefor you need a class deriving from MHAlpha which supports
1204 this variable (one is already existing: MHTheta, which is now the
1205 default in ganymed). It is setup through ganymed.rc
1206
1207 - added a full featured spectrum program (sponde) which reads
1208 ganymed output and monte carlos and compiles a spectrum
1209
1210
1211
1212 *** Version 0.9.1 (2005/04/14)
1213
1214 - Fix bug on the arrival time reconstruction when using Digital
1215 Filter (in some marginal cases (10%) times were reconstructed shifted
1216 by 0.2 slices)
1217
1218 - all executables now return 2 where in previous versions -1 has
1219 been returned (gave problems with shell-scripts)
1220
1221 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1222 also done with a intercalibration input file
1223
1224 - a bug in the time fine adjustment of the digital filter has been fixed
1225
1226 - a lot of small fixes to calling TPad::Divide with a margin==0
1227
1228 - MStatusDisplay now shows the memory usage
1229
1230 - added a memory leak statistic after the eventloop
1231
1232 - MHadronness replaced by MParameterD
1233
1234 - MEnergyEst replaced by MParameterD
1235
1236 - wobble mode can now be switched on from the data-set
1237
1238 - switched on bad pixel detection for a pedestal level
1239 which is more than 5 times the variance
1240
1241 - Fixed default paths to be correct for the new data center
1242
1243 - Fixed handling of drive data. The pointing position in now
1244 copied to MPointingPos inside star for real and MC events
1245
1246 - made sure, that the sequences in a dataset are sorted by
1247 their number to ensure the correct synchronization
1248
1249 - added all resource files necessary to handle spline extraction
1250 of signal for the late 2004 and the early 2005 data
1251
1252 - update the reference lines for the december data
1253
1254 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1255 This is important for the Dec. and Jan. data where the calibration
1256 pulse position changes much.
1257
1258 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1259 filter. This corrects only an defective extraction of the MC at
1260 low-gain signals lower than 90 phes.
1261
1262 - fixed some slowdown in calibrating data with interleaved events from
1263 Jan and Dec. As a workaround made the pretty palette the default.
1264 The inverse Deep Blue Sea has a bug which slows down long calibration
1265 runs a lot.
1266
1267 - implemented new values from new starguider report as defined
1268 in TDAS00-07 V7.1 (eg SkyBrighness)
1269
1270 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1271 in starguider report (If you merpp the same reports with this version
1272 you'll get the correct units (arcmin) but a different result
1273 than with old versions (wrong units))
1274
1275 - Now the status display can also write PNG, JPEG and XPM (other file
1276 formats are still unsupported by root)
1277
1278 - added a lot of scripts and macros in directory datacenter used
1279 for automatic processing
1280
1281
1282
1283 *** Version 0.9 (2005/03/23)
1284
1285 - Calibration is now done autmatically into photo-electrons like
1286 decided by the Collaboration Board
1287
1288 - Reference lines in the display can be read from resource file
1289
1290 - Interlaced calibration events can be handled by callisto
1291
1292 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1293 and applied in callisto.
1294
1295 - class MJCalibTest can be called by callisto
1296
1297 - callisto can now run with three data types: rawdata, rootdata, MC
1298
1299 - added two classes mreport/MReportStarguider.cc and
1300 mreport/MReportStarguider.h for implementing starguider-data
1301
1302 - the output of merpp-update now contains starguider information:
1303 MReportStarguider and MTimeStarguider
1304
1305 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1306 values were lower than they should. This was more visible for high
1307 energy (Size) events.
1308
1309 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1310
1311 - added a new loop to callisto to support the correct extraction of
1312 the pedestal and pedestal rms through the signal extractor
1313
1314 - added class to perform fourier tranformation of a hexagonal structure
1315 (MHexagonalFT)
1316
1317 - added class to perform fourier tranformation of a hexagonal structure
1318 in a tasklist (MHexagonalFTCalc) example: hft.C
1319
1320 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1321 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1322 small pixels, example: extendcam.C
1323
1324 - added possibility to write data to memory (TTree) using MWriteRootFile
1325
1326 - added possibility to read a TTree stored only in memory by MReadTree
1327
1328 - new classes to deal with the interleaved calibration events:
1329 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1330
1331 - implemented filters to callisto to skip calibration events
1332
1333 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1334 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1335 the slices by statistics
1336 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1337 signal extractor without randomization
1338 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1339 with the signal extractor with randomization (extraction window is
1340 randomly fixed)
1341 The three kind of pedestal is not yet implemented (for speed reasons) as
1342 long as nobody really needs it:
1343 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1344 extracted with the signal extractor with randomization
1345
1346 - callisto now finds the pulse position in the data automatically
1347
1348 - implemented data reduction in calibrated data by reducing the precision
1349 of the stored floating point values (pedestal, rms and signal) to
1350 roughly 0.5%
1351
1352 - fixed showplot to make file format conversion (eg. converting a
1353 status display stored in a root file into a postscript file) in
1354 batch mode possible:
1355 showplot -b --save-as-ps[=outfile.ps] infile.root
1356
1357 - Allow class names as part of filter rules, eg
1358 (MFSupercuts) && (MHillas.fSize>100)
1359
1360 - fixed a lot of stuff to allow all programs to process MonteCarlo
1361 camera files.
1362
1363 - enhanced possibility to debug reading of resource file
1364
1365 - MDataChain should handle priorities of operator more
1366 accurate now
1367
1368 - completely revised the container in which the signal is stored
1369 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1370 * the new implementation is faster and
1371 * needs less storage space
1372
1373 - FIRST version which can process Monte Carlos through the
1374 whole chain of programs (callisto, star, etc)
1375
1376 - implemented new image parameters for the border length of
1377 the shower image (MNewImagePar2)
1378
1379 - implemented wobble-mode in ganymed
1380
1381 - new class (MJOptimize) taking care of all optimization processes
1382
1383
1384
1385 *** Version 0.8.6 (2004/10/05)
1386
1387 - New combined signal and time extractor
1388 MExtractTimeAndChargeDigitalFilter
1389
1390 - The Report for the trigger section in the CC run summary has been
1391 updated, and now the IPRs (Individual Pixel Rates) are available.
1392
1393 - new macros for database interaction: filldotrun.C, filldotrbk.C
1394
1395 - added new program which can convert colored output which was redirected
1396 into a file back into colored text (for example to display it with
1397 more): showlog
1398
1399 - added new program to display an MStatusArray of plots (stored with
1400 MStatusDisplay) from a file: showplot
1401
1402 - Added support for Sequences (MSequence). Sequences are blocks of run
1403 files containing the same calibration and belonging to the same
1404 source
1405
1406 - Added a new task (MTaskEnv) which can be used in setup files to switch
1407 between different tasks (for example to choose a signal extractor)
1408
1409 - Implemented automatic file splitting in MWriteRootFile
1410
1411 - After image cleaning an island index is assigned to all used pixels.
1412 The index corresponds to the order of the islands in size.
1413
1414 - added a cleaning which takes signal height _and_ arrival time into
1415 account: probability cleaning (for more details see MImgCleanStd)
1416
1417 - added a cleaning which takes takes the absolute number of photons
1418 times the area ratio as cleaning level
1419 (for more details see MImgCleanStd)
1420
1421 - Changed calculation of image parameters such, that it can be done
1422 for all used pixels or the pixels with a defined island index only
1423
1424 - implemented new image parameters displaying the number of islands,
1425 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1426
1427 - event display in executable changed to support also calibrated files
1428 (done with MJCalibrateSignal)
1429
1430 - added program doing the calibration and the signal extraction
1431 and signal calibration: callisto Most part of the setup is done
1432 by a resource file: callisto.rc
1433
1434 - implemented support for pixels with negative IDs (Raw file format
1435 version 4)
1436
1437 - implemented an new option in merpp (--auto-time) to get the time
1438 range for cc and/or caco data from the run header of the raw data
1439
1440 - New star-program (star and MJStar). Taking calibrated data from
1441 callisto/MJCalibrateSignal as input. The setup is done through
1442 a resource file: star.rc
1443
1444 - Added possibility to setup the eventloop in the mars-executable
1445 Camera Display by a resource file: mars.rc
1446
1447 - The the mars-executable Camera Display can now also read
1448 calibrated data files written by callisto/MJCalibrateSignal
1449
1450 - Added a new class which can calculate the source position in
1451 the camera from a pointing model known to be correct and
1452 the pointing model used for observations (MSrcPosFromModel)
1453
1454 - added a new version of the class calculating the effective on-time
1455 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1456 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1457 MHTimeDiffTheta.
1458
1459 - added the possibility to count how often a signal is above (or
1460 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1461 can replace MHTriggerLvl0)
1462
1463 - added ore convinient ways to set the axis-titles of your histograms
1464 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1465 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1466
1467
1468
1469 *** Version 0.8.5 (2004/08/06)
1470
1471 - new Signal Extractors: MExtractFixedWindowSpline
1472 and MExtractAmplitudeSpline
1473
1474 - implementes interleave in merpp to be able to merpp parts of a file
1475
1476 - implemented force-functionality to merpp
1477
1478 - star display to display star catalogs (MAstroCatalog)
1479
1480 - star display to 'mirror' stars to the camera (MAstroCamera)
1481
1482 - implemented a new cleaning option which allows cleaning scaled with
1483 the real ratio of the rms depending on the pixel size, not only the
1484 square root of the pixelsize (MImgCleanStd, MCameraData)
1485
1486 - removed obsolete MBlind* classes
1487
1488 - Signal extractor taking the AB flag into account implemented (this makes
1489 an odd number of slices for signal extraction possible
1490 (MExtractSignalABcorr)
1491
1492 - implemented a class extracting the pedestal from the raw-data (events)
1493 itself using empty lo-gain (MpedCalcFromLoGain)
1494
1495 - Added mean values to MPedPhotCam
1496
1497 - Added Makefile for Darwin (this OS is NOT officially supported!)
1498
1499
1500
1501 *** Version 0.8.4 (2004/04/19)
1502
1503 - new fast arrival time extractor using cubic splines:
1504 MExtractTimeFastSpline
1505
1506 - implementes multi-argument support in MDataChain
1507 ("pow(a, b)")
1508
1509 - implemented double reference support in MDataChain
1510 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1511
1512 - added support in MF for expressiond like
1513 "MHillas.fWidth<2*<MHillas.fLength"
1514
1515 - MDataChain is now able to support variables like [0], [1], ...
1516 which can be used in fit functions as parameters. The interface
1517 is implemented through the new virtual function
1518 MParContainer::SetVariables
1519
1520 - added new class MArrivalTimeCam/MArrivalTimePix:
1521 Storage containers to hold the ArrivalTime of the camera/pixel
1522
1523 - added new classes for the calibration of relative arrival times:
1524 MCalibrationRelTimePix and MCalibrationRelTimeCam
1525
1526 - added new classes to extract the signal of the blind pixel and the
1527 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1528
1529 - added new classes for the bad-pixels treatment (MBadPixels*)
1530 which are more powerfull than the old ones (MBlindPixel*)
1531 and will replace them.
1532
1533 - added filter against cosmics: MFCosmics
1534
1535 - added new class MArrivalTimeCalc2:
1536 Calculates the arrival time as the signal weighted mean of the time
1537 slices in the maximum window
1538
1539 - added a new macro call pointspreadfucntion.C that fits with a 2D
1540 gaussian the DC spot for an star. It gives you the RMS of
1541 the PSF and the center of the star, very useful for misspointing
1542 studies.
1543
1544 - added support for multi-telescope camera files. Added classes
1545 MStereoCalc and MStereoPar, classes to calculate and store shower
1546 parameters calculated from the data of two telescopes, for the MC
1547 studies regarding the MAGIC clone.
1548
1549 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1550 MC data calibrated in photons instead of ADC counts.
1551
1552 - added three macros to show the calibration and analysis chain of
1553 MC data. The macro starmc.C does both calibration and analysis, producing
1554 an output containing Hillas parameters for each event. The macro
1555 mccalibrate.C does just the calibration and writes out a file containing
1556 pixel information in photons instead of FADC data. The macro starmc2.C
1557 reads in such a file and produces an output with Hillas parameters.
1558
1559 - added MPedPhotCalc to compute pedestals in units of photons, see
1560 macro pedphotcalc.C
1561
1562 - added all class to perform the calibration, see macro calibration.C
1563
1564 - added class MFFT to perform Fast Fourier Transforms
1565
1566 - added class MSimulatedAnnealing to perform simulated annealing
1567 minimizations
1568
1569 - added new macro bootcampstandardanalysis.C which holds the skeleton
1570 of the analysis chain discussed in the december bootcamp.
1571
1572 - added support for DAQ raw data file format V2
1573
1574 - implemented an arbitrary time stamp for the events from raw-data
1575 files with file version<3. It is calculated from the run number,
1576 the date of start and the FADC clock tick from the first module
1577
1578 - implemented the correct decoding of the event time-stamp
1579 coming from the DAQ for raw-data files with file-version>2
1580
1581 - added a new classes storing the pedestals in units of photons:
1582 MPedPhotPix, MPedPhotCam
1583
1584 - added support for DC current files from the camera control
1585
1586 - added support for start- and stop-time when merpping report files
1587
1588 - added MReportCC storing the weather data from the CC-REPORT
1589
1590 - added class to fill trainings and test matrices (MTFillMatrix)
1591
1592 - added a filter performing a software trigger (MFSoftwareTrigger)
1593
1594 - Added classes to perform parts of the standard analysis (Jobs):
1595 + MJPedestals
1596 + MJCalibration
1597 + MJExtractSignal
1598 Note: All of them are preliminary!
1599
1600 - Added Iterator to iterate over files giving only the run-number
1601
1602 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1603 the evolution of a sector vs time
1604
1605
1606
1607 *** Version 0.8.3 (2003/12/05)
1608
1609 - adapted Random Forest classes to allow the use with MC
1610 multi-telescope files which can be produced with the coming
1611 camera version 0.7.
1612
1613 - added classes to read and interprete central control report files
1614 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1615
1616 - enhanced merpp (the executable) to support .raw and .rep files.
1617
1618 - added classes for light calibration (MCalibration* and
1619 MHCalibration*) by Markus Gaug. Further work has to be and will
1620 be done soon.
1621
1622 - Added a preliminary 'synchronizer' (MReadReports) which will
1623 replace MReadMarsFile as soon as it is finished.
1624
1625 - Added a tutorial macro demonstrating how report files are merpped
1626 and how they can be read from the root file in the correct order
1627 of time (readrep.C)
1628
1629 - Added a generalized histogram (similar to MH3) called MVsTime
1630 which allows to plot variables (or rules - MDataChain - of
1631 variables) vs time. For an example have a look at tempvstime.C.
1632
1633 - Changed the name of the event trees:
1634 + Events --> Events
1635 + PedEvents --> Pedestals
1636 + CalEvents --> Calibration
1637
1638 - changed name of MTime in the event trees from MRawEvtTime to MTime
1639
1640 - added displaying the sector indices to the mars event display
1641
1642 - Magic Online Analysis (MOnA) implemented in a first version
1643 (see mona.cc, MOnlineDump and MOnlineDisplay)
1644
1645 - added classes to calculate event rate
1646 (preliminary: MEventRateCalc, MEventRate)
1647
1648 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1649
1650 - added classes dealing with the telescope pointing position (MPointing*)
1651
1652 - implemented the 'final' Mars time stamp based on some experiences with
1653 the new 'Synchonizer'
1654
1655
1656
1657 *** Version 0.8.2 (2003/11/10)
1658
1659 - accelerated standard analysis by a factor of 6-8 ...
1660 + doing precalculations in MGeomCam for the pixel area ratio
1661 + creating a look up table for the single pixels in MCerPhotEvt
1662
1663 - added task to calculates weights in case you want to 'change'
1664 the energy spectrum of a monte carlo file
1665 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1666
1667 - added a new executable star which implements the
1668 star.C macro as precompiled executable. Currently a flexible
1669 setup is not possible, but a 'input card' setup will follow.
1670
1671 - Starting to implement Multi-Telescope-Support based on the
1672 upcomming camera version 0.7. The base for a general support
1673 is implemented and the star-functionality is proven to work.
1674
1675 - Replaced Event-Display in and Camera-Display in the Mars GUI
1676 executable by a more convinient display base on MStatusDisplay.
1677
1678 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1679
1680
1681
1682 *** Version 0.8.1 (2003/10/20)
1683
1684 - added signal subtraction for pure on data by means of fitting
1685 the background in the off region or by performing a combined
1686 signal/background fit. Provides necessary histograms for
1687 obtaining energy spectra and a light curve.
1688
1689 - added classes to perform and study the selection of the
1690 2nd Level Trigger on MC data (example in triglvl2.C macro)
1691
1692 - added pedestal calculation
1693
1694 - implemented "democratic cleaning" (tail cut value proportional
1695 to pixel area) according to Wolfgang's suggestion.
1696
1697 - added Sigmabar treatment (calculation and basic histogramming)
1698
1699 - added basic routines to apply padding
1700
1701 - added first implementation of MARS-based source visibility plotter
1702 (needs to be linked against slalib, preliminary version)
1703
1704 - enhanced functionality of data chains: random numbers, conversion
1705 functions and access to MHMatrix objects
1706
1707 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1708 numbers under certain circumstances (runs with 0 events included)
1709
1710 - fixed a bug in the general filter MF (didn't work on some systems
1711 at all)
1712
1713 - fixed a bug in chaining files, which caused the analysis to crash or
1714 ignore files
1715
1716 - implemented more geometry classes describing the parameters used
1717 to simulate the PMT camera
1718
1719 - added new Monte Carlo classes containing the setup of the different
1720 programs in the MC chain.
1721
1722 - added a (preliminary) general task to evaluate chi-square of a given
1723 parameter in an eventloop.
1724
1725 - first implementation of a container describing the observatory
1726 location (Long, Lat, etc)
1727
1728 - added Random Forest - method for g/h-separation
1729
1730 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1731 (this means, that it is compiling, but not yet fully tested)
1732
1733 - added a new status display which can show the present status
1734 of histograms while an eventloop is running (MStatusDisplay,
1735 an example can be found at status.C)
1736
1737 - reorganized directories:
1738 classes describing the image --> mimage
1739 classes containing Monte Carlo Histograms --> mhistmc
1740 classes for Random Forest method --> mranforest
1741
1742 - added (event-)weights to fill histograms
1743
1744 - colors in logging output to screen
1745
1746 - changes to the Image Parameter declaration:
1747 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1748 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1749 + MHillasExt now derives from MParContainer instead of MHillas
1750 --> Files written with the old definition are more or less unreadable
1751
1752 - reading of reflector files
1753
1754 - display data from reflector files in the camera
1755
1756 - implemented currents (and display them in the camera)
1757
1758 - logarithmic scale in camera
1759
1760 - added class to iterate through directory contents (MDirIter)
1761
1762
1763
1764 *** Version 0.8 (2002/11/18)
1765
1766 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1767
1768 - corrected 48(!) wrong entries in the Next Neighbor table of the
1769 Magic Camera (all in the inner part of the outer ring, mostly
1770 missing a single NN)
1771
1772 - Fixed a bug in the table describing the Next Neighbours of the
1773 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1774 have any neighbour)
1775
1776 - changed trigrate.C: now it calculates the pure NSB triggers from
1777 a camera file (generated with no showers), so there is no need
1778 to introduce them by hand in the BgR array (for more details
1779 please ask Abelardo)
1780
1781 - added MHHadronness (and MHadronness) as a general facility to evaluate
1782 the quality of a gamma-hadron seperation method
1783
1784 - changed MWriteAsciiFile to accept rules (MDataChain)
1785
1786 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1787 must be replaced by calles to MWriteAsciiFile::AddColumn and
1788 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1789 changed.
1790
1791 - Implemented generalized event-matrices (one row per event)
1792 (MHMatrix)
1793
1794 - implemented the one dimensional composite probabilities
1795 (MHCompProb, MCompProbCalc, comprob.C)
1796
1797 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1798 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1799
1800 - Added a camera display displaying the pixel numbers to the
1801 event display gui.
1802
1803 - Added Monte Carlo Informations to event display gui
1804
1805 - Changed the camera display to display the pixel numbering
1806
1807 - Added three buttons to the camera display to change the palette
1808
1809 - Added the number of used and core pixels after image cleaning
1810 to MHillas
1811
1812 - Changed the algorithm used in MHillas according to TDAS 02-03
1813
1814 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1815
1816 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1817
1818 - Added fCosDeltaAlpha to MHillasSrc
1819
1820 - The numbers of photons used to calculate fConc and fConc1 in
1821 MHillasExt are now scaled with the pixel size, so that one get
1822 a four times smaller value for the bigger pixels in the outer ring.
1823
1824 - added new task to smooth the camera contents (MCameraSmooth)
1825
1826 - added possibility to use interpolated pixel values for blind pixels
1827 instead of removing it completely from the analysis
1828
1829 - Implemented the possibility to save the whole eventloop with
1830 its setup to a file. This information can be read and from
1831 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1832 and MEvtLoop::MakeMacro. If you find something not working, please
1833 report - this stuff is still in a beta phase.
1834
1835 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1836 file having crab starfield, but also for all following files - fixed
1837
1838 - MTaskList::PrintStatistics can now be instructud to print also the
1839 title, too: use PrintStatistics(0, kTRUE)
1840
1841 - Changed the image cleaning so that pixels with to many 'used'
1842 neighbors are left used (to get rid of 'holes' in events)
1843
1844 - Introduced more output to the camera displays
1845
1846 - Added an array of histograms (eg one hist per run), MHArray
1847
1848 - Added a _preliminary_ version of the reader for CT1 PreProc files
1849 (MCT1ReadPreProc)
1850
1851 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1852 (thanks to Raquel)
1853
1854 - added the first energy estimator (MEnergyEstParam, estimate.C,
1855 estfit.C) using a parametrization
1856
1857 - Added some new Monte Carlo paremeter containers used to store
1858 setup information from the MC chain (MMcConfigRunHeader,
1859 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1860
1861
1862
1863 *** Version 0.7 (2002/04/30)
1864
1865 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1866 the pedestal mean value was saved incorrectly. For files from
1867 this versions we substract 0.5 from the pedestal mean.
1868 WARNING: This may effect your results, so don't wonder...
1869
1870 - First implementation of an algorithm using only triggered events
1871 for the collection area calculation
1872
1873 - Ascii Output can now also be used for parameter containers which
1874 doesn't overload MParCointainer::AsciiWrite
1875
1876 - The Ascii Output is now also capable of writing single data members
1877 of one container
1878
1879 - You are now able to change the order of the values written to the
1880 ascii file
1881
1882 - You can now specify a conversion factor for each data member written
1883 to an ascii file. This may be usefull to change the units of the
1884 data member (eg. degrees instead of millimeters in case of the
1885 hillas parameters)
1886
1887 - Replaced old MHillas by a new structure which allows you to extend
1888 the parameters stored in MHillas very easily:
1889 see MHillas and MHillasExt
1890
1891 - Added classes to handle source dependancy of image parameters:
1892 see MHillasSrc
1893
1894 - Added container (MBinning) to have a standard input for the binning
1895 in different histograms (eg. the Energy bins should be the same in
1896 all histograms)
1897
1898 - Changed Hillas histograms from mm to deg
1899
1900 - Added the flexible binning to the hillas histograms
1901
1902 - Added a filter for the alpha parameter (MFAlpha)
1903
1904 - It is now possible to write single data members of a class object to
1905 an output stream instead of the whole container only
1906
1907 - Added a generalized filter for a data member:
1908 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1909
1910 - Added a generalized Filter parser for more difficult filter rules
1911 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
1912
1913 - Added new Monte Carlo histograms:
1914 MHMcEnergyImpact and MHMcEfficiency
1915
1916 - Added many new histograms needed for the flux calculation.
1917
1918 - Added a generalized histograms which can fill and show up to three
1919 data members in either a one-, two- or three-dimensional histogram, eg:
1920 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
1921
1922 - Added:
1923 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
1924 * calculation of <Theta> as a function of time (MHThetabarTime)
1925 they are needed in the flux calculation in
1926 order to select for a given bin in Theta (or time) the appropriate
1927 effective collection area, which is assumed to be given as a function
1928 of Theta and the true energy
1929
1930 - Added calculation of the migration matrix in the energy
1931 (MHMcEnergyMigration):
1932 the migration matrix describes the migration from the true (E_true)
1933 to the estimated energy (E_est); it is needed to determine the
1934 distribution of E_true from the measured distribution of E_est
1935 by unfolding
1936
1937 - changed the color palette in the camera display to DeapSea.
1938
1939
1940
1941 *** Version 0.6 (2002/01/15)
1942
1943 - Introduce the option of disable pixels (MBlindPixels and
1944 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
1945 able to deal with Star Field NSB.
1946
1947 - Fixed a bug in the pedestals substraction
1948
1949 - Introduced verbosity levels
1950
1951 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
1952
1953 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
1954 work correctly (thanks to Abelardo)
1955
1956 - Introduced correct treatment of the diffuse Night Sky Background
1957 and NSB (MMcPedestalNSB)
1958
1959 - Corrected treatment of the electronic noise (MMcPedestalCopy)
1960
1961 - Introduced MMcRunHeaders which contains monte carlo run informations
1962
1963 - Added a 'Print'-Task (MPrint) which calls the Print function
1964 of a parameter container for each event
1965
1966 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
1967
1968 - changes to be more efficient with root 3.02/06
1969
1970 - root 3.02/06 fixes:
1971 + the memory leak when reading MRawEvtData
1972 + loosing more time than necessary to update the progress bar
1973
1974 - MWriteAsciiFile is now capable of writing more than one container
1975 in a line. For example: To be able to write Monte Carlo and
1976 Hillas values (energy and alpha) in one line.
1977
1978
1979
1980 *** Version 0.5 (2001/11/06)
1981
1982 - Added new GUI functionality (Analysis)
1983
1984 - Added a camera display to be able to display events in the camera
1985 together with the calculated hillas ellipse
1986
1987 - Added a 'Clone'-Task (MClone) which can clone a parameter container
1988 object at any state of the analysis, so that the output are several
1989 states
1990
1991 - Fixed a bug in the collection area error calculation
1992 (Thanks to Ciro and Abelardo)
1993
1994 - Fixed a bug which causes merpp to crash in some environments
1995
1996 - Implemented auto enabling scheme for Branches to speed up reading
1997 a lot (see MReadTree and MTask)
1998
1999 - Fixed a bug in the Histogram classes which caused histograms to
2000 be written to a file by MWriteRootFile without request
2001
2002 - changed the object I/O from the old stylish root I/O to the new
2003 'auto evolution scheme' This was done only for classes which are not
2004 yet used in Monte Carlo files, so that these files are still readable.
2005
2006 - Added support for a progress bar in MEvtLoop and MReadTree
2007 (see the Analysis Window in Mars for an example)
2008
2009 - Fixed a bug in the package creation which disturbed the conversion
2010 between a mars version unpacked from a tar file and the repository.
2011
2012 - Changed the code to writer merpped (converted into root format)
2013 raw files, to get faster (around 10%)
2014
2015
2016
2017 *** Version 0.4 (2001/09/20)
2018
2019 - This release is made to compile on a root version >= 3.00
2020
2021 - Fixed a bug which causes MReadTree to read the first file only
2022
2023 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2024
2025 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2026
2027 - Added a task to write several container to a root file (MWriteRootFile)
2028
2029 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2030
2031 - Added calculation of the collection area (MMcCollectionAreaCalc)
2032
2033 - fixed some bugs in the Hillas calculation
2034
2035 - added filters to be able to control the task execution dependent on
2036 a parameter (for example: the number of level 1 triggers in a MC-file)
2037
2038
2039
2040 *** Version 0.3 (2001/04/23)
2041
2042 - Many demo macros added
2043
2044 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2045
2046 - Hillas Calculation added
2047
2048 - Standard image cleaning available
2049
2050 - MReadTree is now able to handle more than one file
2051 (Remark: of the same structure)
2052
2053 - Now we are able to display events in a first version of the
2054 Camera event display. To do this we must run the macro
2055 "macros/readCT1.C" to read data from CT1.
2056
2057
2058
2059 *** Version 0.2 (2001/01/24)
2060
2061 - First Implementation of a Gui to read the raw data. Start the
2062 gui with the command mars.
2063
2064
2065
2066 *** Version 0.1 (2000/12/20)
2067
2068 - First official release 0.1
2069
2070 - Changes:
2071
2072 + changed calling style of MRawPixelIterator from do...while to
2073 while-loop
Note: See TracBrowser for help on using the repository browser.