source: trunk/MagicSoft/Mars/NEWS@ 8431

Last change on this file since 8431 was 8431, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 88.0 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - general: The new class MGeomCamDwarf contains the camera geometry
6 for our prefered Dwarf camera and can be used to create general
7 geometries of roundish or hexagonal cameras.
8
9 - mars: The default cleaning is now abolute 8.5/4.0.
10
11 - mars: The resource file mars.rc now contains examples for MUX data
12
13 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
14 data containing only 10-bit information is still cooked down to
15 8-bit, by cutting away the lowest 8-bit.
16
17 - merpp: When reading raw data the data is now stored in a single
18 array. The lo-gain array is obsolete. The interface stays the same.
19
20 - callisto: Started further simplification by removing obsolete
21 dependancies on MCalibIntensity*Cams.
22
23 - callisto: removed unsused intensity calibration from MJCalibration
24 for further simplification
25
26 - callisto: for simplification removed references to MBadPixelsIntensityCam,
27 MCalibrationIntensityQECam, MCalibrationIntensityRelTimeCam,
28 MCalibrationIntensityTestCam, and MCalibrationIntensityBlindCam
29
30 - callisto: Added the option to write an event movie. Please use
31 this option with care (huge files) but exessively to understand
32 our events. For further documentation please refer to the
33 IACT wiki
34 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
35
36 - callisto: Improved binning for the pulse position check histogram
37
38 - callisto: The code calculating the pulse position checknow takes
39 the pedestal into account
40
41 - callisto: The arrival time is now stored with full precision this
42 helps to get rid of artefacts in histograms. For the signal this
43 is not necessray because it is displayed in log-scale anyhow
44
45 - ganymed: The output files now contain run- and event-number for all
46 events, accessible as RunNumber.fVal and EvtNumber.fVal
47
48 - ganymed: Added a plot showing the source position in the camera also
49 for wobble mode
50
51
52
53 *** Version 1.0 (2007/02/16)
54
55 - database: Website to plot values from the database has been added.
56
57 - database: The rate of spark events as found by star is now kept
58 and the rate after cleaning is now with spark events subtracted
59
60 - general: The changes to the interpretation of phrases lead to
61 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
62
63 - general: Added example files how you can create your own calendar
64 (eg. as christmas present) with Mars. Just run
65 root macros/tutorials/calendar.C
66
67 - general: Added a possibility to display grouped data in the plotdb.C
68 macro (and similar macros). This allows to plot hourly, nightly,
69 weekly, monthly and yearly averages.
70 For more details see the plotall function of the macro
71
72 - general: fixed the error display of the camera display. It showed
73 wrong results.
74
75 - general: fixed a memory leak when reading many MStatusDisplays
76
77 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
78 between a spherical and a parabolic mirror
79
80 - callisto: We have a new pulse position check which takes the properties
81 of the extractor automatically into account. So no need to set
82 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
83 left is done. If possible the lo-gain extraction start and hi-gain
84 extraction end is changed accordingly. If no proper extraction range
85 can be set (hi-gain too much to the left) an error is raised.
86
87 - callisto: New swapped pixels have been found and corrected
88
89 - callisto: Redone the signal extraction this includes:
90 + Unified the algorithms to extract the pedestal for all pedestal
91 extractions done
92 + Unification of hi- and lo-gain into one array
93 + Unification of hi- and lo-gain extraction for Spline and
94 Digital Filter (means now exactly the same algorithm is used,
95 not a copy-and-pasted one)
96 + Store pedestal subtracted data in a common place
97 + Improved extraction algorithms. If the algorithms search a
98 maximum but don't find one they don't return the maximum anymore
99 + Improved the extraction such that a information for signal
100 and time which is consistent is returned
101 + replaced the numerical spline with a (not slower) analytical
102 solution
103 + Lowered the saturation limit from 250 to 245 to make sure that
104 we are far away in all pixels from problems with the clock-noise
105 + The start of the lo-gain extraction is calculated from the hi-gain
106 arrival time. In case of saturation an estimation is used.
107 + the hi-gain window was extended to slice 16. This allows extraction
108 of very late pulses in single pixels or of huge hadron showers.
109 + Now uses the lo-gain extraction range for pedestal extraction,
110 not the hi-gain range in the lo-gain
111
112 - callisto: New hi-/lo-gain calibration constants have been produced
113 for all periods from the statistic of the whole period. They are
114 now used automatically depending on the periods. The old constants
115 where deviation in avarega about 2%-3%. The constants are very
116 stable from period to period (<<1%) except for exchanged channels.
117 In a few cases the constants used so far were off by 1%-2% (maybe
118 temperature effects?)
119
120 - callisto: To gain obsolete space we do not write the
121 MPedestalFundamental anymore. Also calibration and bad pixel
122 treatment is not done for it anymore because it has never been used.
123
124 - callisto: Fixed a bug in the seuqence handling which caused the
125 light condition to be ignored
126
127 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
128 basically the same as "Cleaned" but the distribution devided into
129 the events fullfilling a spark cut or being rejected by it.
130 This cut can be changed from star.rc (see example inside) by
131 the "SparkCut" directive
132
133 - star: Star displays now the average individual pixel-rate (IPR) versus
134 time and the average discriminator threshold (DT) of all pixels.
135
136 - optim: fixed a problem with the optim-macros which was due to a bug
137 in the new phrase parsing
138
139 - ganymed: To get a nice FalseSource plot (instead of the all-information
140 debug plot displayed as a standard plot) use the context menu
141 somewhere between the two upper plots, click on "DrawNicePlot"
142 and enjoy the result. (It is the same context menu which contains
143 the other options)
144 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
145
146 - ganymed/optim/train: The cut program, trainings- and optimization
147 macros could run with less files found than expected from the
148 sequence-files. No the execution is stopped in this case.
149
150 - ganymed: now stores the dataset in the output file with all information
151 contained (as sequence number, sequence path, data path) so that the
152 used dataset file can be recreated complete from the output
153
154 - sponde: now also allows the uasge of random forest
155
156 - sponde: added a plot showing the cut efficiency
157
158 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
159 errors (eg. effecting the collection area) because the errors of the
160 two histograms were swapped in the calculation, which makes a difference
161 in the case the histograms contains weighted events. Aditionally the
162 totalarea was incorrectly taken into account, which results in too small
163 errors, which makes a difference at low statistics were the errors
164 or the collection area dominate.
165
166
167
168 *** Version 0.10.3 (2006/10/23)
169
170 - database: Implemented ObservationMode flag in websites.
171
172 - database: For sequences there is now also the stoptime available on the
173 websites.
174
175 - database: Removed ManuallyChanged flag from sequence-info websites,
176 as it is not needed anymore with the new sequence building algorithm.
177
178 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
179 Class for calculation of confidence intervals (upper limits).
180 Use model 3 or 4 for upper limit calculation for MAGIC observations.
181 Please read the class instruction of TRolke for more information.
182
183 - general: The programs now return 0xfe if the requested resource file
184 doesn't exist.
185
186 - general: Errors comming from root itself are now not output to
187 stderr anymore but to our default (colored) log-stream.
188
189 - general: Changed the interface to TFormula such that now everything
190 is parsed by TFormula, which should allow to use phrases even
191 without paranthesis correctly parsed.
192
193 - callisto: replaced the AdHoc number of effective integration slices
194 in the digital filter by an average of the correct number, averaged
195 over all possible set of weights. This also gives correct numbers
196 for the lo-gains which were totally wrong before.
197
198 - callisto: drastically reduced memory consumption by not storing
199 all intermediate calibration results in memory anymore (we might
200 write them into a file in the future)
201
202 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
203 debug plot displayed as a standard plot) use the context menu
204 somewhere between the two upper plots, click on "DrawNicePlot"
205 and enjoy the result. (It is the same context menu which contains
206 the "DrawAll" option)
207 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
208
209
210
211 *** Version 0.10.2 (2006/10/15)
212
213 - general: changed the building of the sequence files such, that
214 the source-/project name in case of wobble-sources is not the
215 source/project of the first data run anymore but the new generalized
216 wobble source/project
217
218 - general: Added some functions to MAstro to calculate sun and
219 moon properties
220
221 - general: Added two new macros (starvisday.C and starvisyear.C)
222 which allow to plot the visibility of several stars in one day
223 or of one star along one year
224
225
226
227 *** Version 0.10.1 (2006/10/11)
228
229 - general: HTML logging output was distorted... fixed.
230
231 - general: Changed the writing of the sequencefiles such that only
232 as many pedestal files as giving at least 1000 pedestal events which
233 are nearby the first calibration run are used as pedestal runs
234
235 - sponde: In the calculation of the collection area(s) and the
236 distribution for MOnte Carlo and estimated energy the error
237 calculation was wrong because root didn't take the errors
238 properly into account... fixed.
239
240
241
242 *** Version 0.10 (2006/10/10)
243
244 - general: all executables now check consistency of the root version
245 installed with the root version used for compilation. The return
246 code in this case is 255.
247
248 - general: The algorithm to build seqeunces has been redesigned
249 completly. It is now more flexible in terms of a resource file
250 resources/sequences.rc which can be used to partly overwrite
251 the default algorithm and defined the important part of the
252 algorithm. It also takes correctly into account several ways
253 of taking wobble-data. Currently the new algorithm doesn't take
254 the number of pedestal events anymore into account (so a sequence
255 could have much less than 1000 pedestal events and data runs are
256 no-more used instead)
257
258 - general: a lot of small changes to make the code compatible with
259 root 5.12/00 and gcc 4.1
260
261 - general: Fixed some warnings thrown if more warnings are switched
262 on in the compiler
263
264 - general: Added a function to MMath which returns the Median of
265 the distribution abs(y[i]-median) but at 68:32 division instead
266 of 50:50, which is somehow the median counterpart of the rms.
267
268 - general: MAstroCatalog allows now to read calatog files (as bsc5)
269 even if they are compressed with gzip (recommended compression
270 is with "-1")
271
272 - showplot:
273 + batch mode creation of image files now works with root 5.12/00
274 + added support for writing bmp (though it never produces
275 bmp which can be read by programs like xv or gimp)
276 + added support for xml
277 + added new option to start the display with a different size, by
278 --display-width=nnn or --display-height=nnn
279 + added options to define the canvas size when the display is started
280 --canvas-width=nnn or --canvas-height=nnn
281 the option can also be used for batch-mode conversion
282 + added an option which automatically fits the display size to the
283 desktop-size: --auto-size
284
285 - merpp: didn't recognize files with the extension .raw.gz - fixed.
286
287 - merpp: allow the reports to have 1000ms due to a bug in the camera
288 program.
289
290 - callisto: New swapped pixels have been found and corrected. For
291 details see MRawRunHeader::FixAssignment()
292
293 - callisto: Callisto now raises an error if one of the input files could
294 not be opened.
295
296 - callisto: In some rare cases it could happen that in the signal
297 extraction of the digital filter the extractor returned nonsense
298 results due a wrong initializion of a variable (this happens in
299 cases in which the extracted signal is exactly zero or the
300 digital filter couldn't slide because of a too small extraction
301 window, which could happen in the lo-gain extraction)
302
303 - callisto: The lo-gains have been marked as valid in some cases
304 when they got not extracted at all (deltsumlo=deltatimelo=0) because
305 the allowed extraction range (fLoGainLast-fLoGainFirst) was
306 smaller than the number of slices (fLoGainWindowSize) needed
307 by the lo-gain extractor
308
309 - callisto: Updated absolute calibration constants (muon calibration)
310
311 - callisto: fixed a bug which caused the hi-gain saturation not
312 to be handled properly in the spline (the position of the
313 saturation was calculated incorrectly)
314
315 - callisto: fixed a bug which gave weird results if hi- _and_
316 lo-gain could not be extracted properly. In some cases hi-
317 and lo-gain have not been extracted at all and the random result
318 got calibrated. In other cases the hi-gain was saturating and the
319 lo-gain has not been extracted. For this a completly arbitraty
320 scale factor was applied to the result from extracting the
321 charge of the saturating hi-gain.
322
323 - callisto: improves handling of extracted signal if lo- and/or
324 hi-gain could not be extracted properly. If no appropriate
325 calibration of either the signal or the arrival time is possible
326 the pixel is now markes as unsuitable instead of estimated.
327
328 - callisto: Fixed a problem in the spline extraction which gave
329 weird results if the signal was extracted from the first (and
330 highest) slice (as a workaround extraction from the first
331 slice has been forbidden)
332
333 - callisto: Fixed a bug regarding the use of the QE which doesn't
334 effect the result because the default is used anyhow.
335 (The bug was there since 14/07/2005)
336
337 - callisto: Changed the default for fgLoGainStartShift to -2.4
338
339 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
340 factors to be always 10 for all pixels as soon as the first
341 calibration update has happend.
342
343 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
344 was off by more than one slice (which gives wrong values for
345 pixels which have saturated the hi-gain) This was a problem
346 mainly for timing studies, not so much for the automatic standard
347 analysis. Also the values for the Spline have been changed slightly:
348 + Digital Filter from 1.70 to 0.95
349 + Spline from 1.39 to 1.30
350 The numbers were sorted out by an extensive test in the
351 test-database.
352
353 - callisto: Removed the tab showing the average calibrated arrival
354 time. It never gave useful information.
355
356 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
357 lo-gain pulse for data pulses if hi- and lo-gain have saturated
358 and both were extracted because the hi-gain was above the
359 LoGainSwitch.
360
361 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
362 lo-gain pulse position (after application of LoGainOffset, which
363 means in the ideal case it is 0) for data pulses if hi- and lo-gain
364 have saturated and both were extracted because the hi-gain was above
365 the LoGainSwitch.
366
367 - callisto: After extensive tests a new threshold level for determination
368 of the pulse position has been found at 50phe. This is due to the
369 fact that for lower pulses the arrival time changes its average
370 behaviour dramatically. It tends to the average of the extraction
371 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
372
373 - callisto: Added two more plots to the calibration part. The average
374 extracted signal and the average extracted arrival time as
375 extracted by the signal extractor (This can help debugging problems
376 because it doesn't involve a fit)
377
378 - star: changed the fit for the effective on time such that initial
379 values are calculated automatically now instead of using build
380 in values. This makes the fit more indepedant of the underlaying
381 rates. With a test of ~350 sequences in the test database it could
382 be shown that the new fit gives the same result +/-1sek.
383 The highest deviation was +5s the lowest -10s. You can now control
384 the bahaviour with two resource values:
385 MHEffectiveOnTime.FistBin: 3
386 MHEffectiveOnTime.NumEvents: 12000
387 Use FirstBin=1 and NumEvents=120 to fit the effective on time
388 from the resulting gamma candidates
389
390 - star: The Center histogram in MHHillas is now by default displayed
391 with the colz draw-option
392
393 - ganymed: now produces valid error codes if failed
394
395 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
396 with the option "hadronness" instead of "area" or "both" if
397 you want to use both cuts. The hadronness cut includes a fixed
398 cut in hadronness (index 8) and a fixed cut in size (index 9).
399
400 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
401 the M3Long of the anti source to be not properly evaluated
402 (actually is was evaluated as a unique random number) in case
403 of optimization with anti-theta cut switched on. This might have
404 lead to improper, but not necessarily wrong, optimization results.
405
406 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
407 how to use random forest
408
409 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
410 ganymed_onoff.rc. Seems to be unintentional that they were different.
411
412 - sponde: Since the introduction of the possibility to define a
413 normalization energy instead of using the integral the default
414 was not using the integral anymore but a normalization energy of
415 1GeV. It is now the integral again.
416
417 - sponde: Fixed a problem in the weighting which did not allow
418 a MC slope of -1.
419
420
421
422 *** Version 0.9.6 (2006/05/24)
423
424 - general: changed the binning of the azimuthal profile of the camera
425 such that it is aligned with the 60deg boundaries.
426
427 - merpp: better handling of problems with the TH, TD part of the
428 CC-REPORT for files older than 200507190 and 200412210
429 respectively
430
431 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
432
433 - merpp: implementd latest changes in starguider reports (sinc 9th May)
434
435 - callisto: if an arrival time is extracted outside the fadc range is
436 was set to the boundary before. Now a random number is assigned
437 instead to avoid unfortunate coincidences of arrival times just
438 by this arbitrary value.
439
440 - callisto: added a new option to callisto.rc which allows
441 to set the maximum arrival time difference allowed for the
442 badpixel algorithm to determin whether a pixels belongs to a shower:
443 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
444
445 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
446 to 0.9 as suggested by Stefan due to a recent study on the fraction
447 of pixels surviving the image cleaning
448
449 - callisto: switched off error in case of "pulse is too much to the left"
450
451 - callisto: The extraction window is not adapted anymore. This means that
452 the pulse is extracted from the full range. The draw-back is that the
453 background (pedestal) will become slightly higher. Switching on/off
454 the PulsePosCheck in the callisto.rc only effects filling the
455 histograms.
456 WARNING: If the pulse is too much to the left data is calibrated!
457 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
458 in the database to make sure that your data is valid!
459
460 - star: Show also the number of stars correlated correctly by the
461 starguider
462
463 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
464 than one off-source region in wobble-mode. To use it add the following to
465 your ganymed_wobble.rc:
466 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
467 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
468 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
469 + Cut1.ThetaCut: None
470 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
471
472 - ganymed: in the case the latest report is older than a default (currently
473 one minute) and the current report will be skip the starguider
474 correction and calibration will be reset. The maximum age can be
475 setup from ganymed.rc by (minutes):
476 MPointingDevCalc.MaxAge: 1.5
477
478 - ganymed: A first implementation showing all size-bins for the theta-sq
479 resp. alpha-plots in a single tab automatically
480
481
482
483 *** Version 0.9.5.1 (2006/05/05)
484
485 - general: Added a new option "zdiff" to the Makefile which runs
486 "cvs diff" as "make diff" would do, but with compression
487
488 - general: accelerated MTFillMatrix (used for eample in all training
489 and optimization macros) by skipping some obsolete calles in the
490 eventloop the first and second loop could be accelerated by ~20%
491
492 - general: Added a missing feature in the MFilterList class which
493 prevented MFEnergySlope from working correctly in trainenergy.C
494
495 - general: Accelerated the random forest training and usage a bit
496
497 - merpp: Adapted to new raw data file format version 6
498
499 - merpp: fixed a problem with reading the starguider reports
500 after 6.3.2006
501
502 - callisto: At some times six pixels had to be exchanged manually in the
503 data. If the pixels to be swaped are both not found, an error was raised
504 and calibration was stopped. Now it is assumed they are intentially not
505 mapped and the Error has been changed to a Warning.
506
507 - star: Added new image cleaning based on the arrival time of the shower.
508 The new cleaning can be accessed using the parameter "Time" instead of
509 the the old one (like "Absolute) in the star.rc-file.
510 Recommended parameters:
511 + MImgCleanStd.CleanLevel1: 8.2
512 + MImgCleanStd.CleanLevel2: 5
513 + MImgCleanStd.CleanRings: 2
514 + MImgCleanStd.KeepSinglePixels: No
515
516 - star: Simplified the calculation of the effective on time. By letting
517 the fit start in the third bin the result should become more stable.
518 The fit quality is now ignored for the theta-plot which is not used
519 in the analysis later. Still better pre-cut which, for example,
520 remove events triggered by car-light (rate changing on a short
521 time-scale) are missing.
522
523 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
524 for optimization (kWeakSource) which is suggested by the Berlin
525 people for weak sources.
526
527 - macros: plotdb.C:
528 + if no dataset and no time-interval is given only sequences with
529 an effective on-time above five minutes are plotted anymore
530 + added a new tab "RelTime" displaying the relative on-time
531 (effective on-time divided by the observation time)
532
533 - macros: optim*.C: by skipping some obsolete calles in the eventloop
534 the optimization became a lot faster
535
536 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
537 To display them just delete the pads displayed on top.
538
539 - ganymed: fixed a bug which could cause strange behaviour in wobble
540 mode if no starguider information was available due to an incorrect
541 initialization of the starguider calibration
542
543 - ganymed: The scale region in the False Source Plot (MHDisp) can now
544 be changed from within the plot. It can also be setup from the
545 resource file using:
546 + MHDisp.fScaleMin: 0.325
547 + MHDisp.fScaleMax: 0.475
548
549 - ganymed, showplot: Fixed a problem with the fit to the off-data
550 (HistOff) which could cause a time lag or an inifinite loop.
551 The bug did not effect the results at all.
552
553 - sponde: Added a new tab showing the effective collection area after
554 trigger (including the software trigger)
555
556 - sponde: MMcSpectrumWeight has a new option which allows to define
557 the scaling factor not by the integral of the events but at
558 a defined energy:
559 e.g. MMcSpectrumWeight.NormEnergy: 200
560
561 - MTFillMatrix, sponde: by skipping some obsolete calles in the
562 eventloops the loop could be accelerated by ~20%
563
564
565
566 *** Version 0.9.5 (2006/03/13)
567
568 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
569 and added the standard Disp-parametrization
570
571 - macros: added a new macro datacenter/macros/plotstat.C allowing
572 to plot statistics about the data processing
573
574 - macros: added a new macro to plot the muon correction coefficients
575 versus period (macros/plot/mucal.C)
576
577 - showplot: path inflation for ganymed files was broken
578
579 - callisto: Fixed an important bug. When the number of saturating pixels
580 were calculated the bad pixel information already available from the
581 calibration was ignored. This yields wrong values in case pixels
582 are broken and saturate all the time or randomly.
583
584 - callisto: Updated Muon calibration constants. Spline data now also uses
585 different values for different periods
586
587 - star: The time-evolution shown in the effective on-time plot now displays
588 the axis range (if there are no holes it should be similar to the
589 effective on-time)
590
591 - star: Added two new image parameters:
592 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
593 the three pixels next to the center of gravity and the size
594 + MNewImagePar.fConcCore: The ratio of the signals of all
595 pixels inside or touching the ellipse and the size
596
597 - ganymed: now stops in requested source isn't found in catalog file
598
599 - ganymed: Many improvements to the phi-plot in wobble mode:
600 + with a template the ideal background is displayed
601 + a possible camera inhomogeneity is taken into account
602 + the anti theta cut is better supported
603 + the phi cut is automatically calculated from the theta cut
604 See the examples in ganymed_wobble.rc for more details.
605
606 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
607 times the bin-width instead of the absolute energy
608
609 - ganymed: New cuts for on/off and wobble mode
610
611 - ganymed: The smearing of the False Source plot has been increased
612 to 0.06
613
614 - ganymed: The starguider calibration can now be changed from the
615 resource file.
616 See the examples in ganymed*.rc for more details.
617
618 - ganymed: added a new option for on-/off-observations
619 MJCut.RandomSourcePosition
620 If switched on the distribution of observation time of the source
621 position in the camera is calculated from the on-data and randomly
622 applied with this distrbution to the off-data.
623
624 - ganymed: by skipping some obsolete calles in the eventloop the
625 first and second loop could be accelerated by ~20%
626
627 - ganymed: The default in ganymed_onoff.rc is now to determin the source
628 position in the off-data randomly according to its distribution in the
629 on-data.
630
631
632
633 *** Version 0.9.4.3 (2006/02/13)
634
635 - general: Fixed a bug in most of the programs which prevented the
636 compile date in the startup message to be displayed
637
638 - general: Simplified program calls. The following abbreviations
639 are now possible:
640 showlog callisto 55599
641 showplot signal 55599
642 star 55599
643 callisto 55999
644 ganymed 2
645 In this cases the corrsponding root-, log-, sequence- or dataset-
646 filename is automatically compiled using the default datacenter
647 paths ("/magic/*")
648
649 - general: Fixed a long outstanding bug which made axis tick marks
650 disappear if MDataFormula was used (eg. abs(x))
651
652 - general: Updated MMath with new functions to calculate the results of
653 a exponential, logarithmic and powerlaw fits analytically.
654
655 - general: Updated some macros with comments:
656 + macros/optim/optimdisp.C
657 + macros/optim/optimenergy.C
658 + macros/optim/optimwobble.C:
659
660 - general: MTFillMatrix (the class to fill one or two MHMatrix from
661 files) now allows adding a pre-cut like in the optimization. E.g. this
662 is useful to perform g/h-separation cuts before training the random
663 forest.
664
665 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
666 correctly assigned in the raw data assignement table. A fix to correct
667 the assignment tabel have been implemented.
668
669 - general: MAstroCatalog now allows rotating of the sky-grid and stars
670 by 90, 180 and 270 deg.
671
672 - general: the macro plotdb.C now allows to highlight sequences belonging
673 to a datset. For more details see the descritions in the macro.
674
675 - StatusDisplay: Fixed the algorithm to calculate the size ratio
676 of the display, it gave wrong results espacially for big sizes.
677 Now the embedded canvas should always have a ratio width/height=3/2.
678 The "Size" options have been updated with values fitting the 3/2
679 size ratio.
680
681 - RanForest:
682 + Updated the random forest classes to support also the
683 regression method implemented by Thomas H.
684 + added new tutorial macro how to train the random forest
685 for energy estimation (macros/optim/rfenergyest.C)
686 + new classes to train the random forest (still in development)
687 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
688 + new tutorial macros for random forest training in macros/train
689 trainenergy.C, traindisp.C, trainseparation.C
690
691 - mars: now allows to setup a cut in the resource file mars.rc to choose
692 the events to be displayed, eg:
693 Cut.Condition: {0} && {1}
694 Cut.0: MHillas.fSize>100
695 Cut.1: MHillas.fSize<900
696
697 - merpp: Made aware of the new .rep format 200510250. This includes
698 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
699 the discriminator thresholds (MCameraTD) and the disciminator
700 delays (MCameraTD). All of them come with the CC report and are therefor
701 written to the CC tree.
702
703 - callisto: fixed a bug in the calculation of the arrival times in
704 the Digital Filter. They were all shifted by the same amount
705 fHiGainFirst. This caused an offset in the order of the position of
706 the left border of the extraction window in the times calculated
707 from high-gain and from low-gain. The bug effected only the absolute
708 arrival times. The bug was there since 30.1.2005.
709
710 - callisto: Changed the ExtractionWindow for the pulse position check
711 such that the camera inhomogeneity becomes as less as possible and
712 comparable to the pulso position check switched off. More details
713 on the study will be given at our result web-page.
714
715 - ganymed: ganymed.rc, ganymed_onoff.rc:
716 changed to new cuts trained with 1ES1218 and Crab-data
717 for maximum sigma*log10(excess)
718
719 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
720 a new option was implemented to estimate Disp (CalcDisp)
721
722 - ganymed: Implemented two new options which allow
723 to overwrite the default path to search for the sequence files
724 --ins=/magic/sequences
725 and where to search for the image data
726 --ind=/magic/data/star
727
728 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
729 dx/dy from the resource file by
730 MSrcPosCorrect.Dx
731 MSrcPosCorrect.Dy
732
733 - ganymed: fixed reading the source catalog. Only as many chars
734 as the requested source name had were compared (If a source
735 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
736 were requested it could happen that the coordinates of
737 "1ES1218" were read) The source coordinates are now printed
738 in addition to its name to the logging output.
739
740 - ganymed: changed the background fit in the case of a ThetaSq function
741 from a polynomial to a exponential, this should give a big improvement
742 for on-only analysis'
743
744 - ganymed/sponde: Calculation of the error of single size-/energy-
745 bins now uses Li/Ma (5) instead of LiMa (17)
746
747 - sponde: Added a plot E^2*dN/dE
748
749 - sponde: The energy estimator plot should now show values like
750 they are commonly used.
751
752 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
753 (a powerlaw with cutoff didn't work before)
754
755
756
757 *** Version 0.9.4.2 (2005/10/01)
758
759 - general: added new tutorial macro macros/tutorials/threshold.C:
760 how to calculate the threshold
761
762 - general: added a new game. Start it from the interpreter with
763 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
764 and MagicReversi)
765
766 - general: neighbor pixels in MGeoms are now sorted clockwise
767
768 - merpp: made aware of new format 20050829-0
769
770 - callisto: New scale factors from muon analysis, stored in new
771 resource file resources/calibration.rc
772
773 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
774 the eventloop if something went wrong. This is necessary for the
775 automatic processing
776
777 - callisto: Implemented a new treatment for the time information
778 developed by S.Ruegamer, this should give much better response than
779 the old very primitive algorithm. This is especially important
780 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
781 treatment was buggy! As neighbor pixels to interpolate the
782 arrival times always the pixels 0 to 5 were taken)
783
784 - callisto: In addition to the new treatment of arrival times the
785 decision of the treatment whether a pixel contains shower
786 information or not is used to improve the signal interpolation
787 further. Previously interpolated pixels showed a non-zero signal
788 do the peak searching signal extractors. Having a signal pixel
789 beside raised the signal above the cleaning level. Thus the
790 pixel survived cleaning to often but with a too low mean signal.
791 By replacing empty pixels with a gaus (mean and rms from the
792 corresponding Area entries in MPedPhotCam) this effect can
793 be supressed.
794
795 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
796 got lost when the events were stored by the calibration... fixed.
797 (This was no problem for normal image cleaning because the pixel
798 content was artificially set to 0 not surviving standard cleaning
799 algorithm)
800
801 - callisto: Fixed a bug which caused the random and peak-search pedestal
802 extracted with an extractor to be exchanged for the first (roughly)
803 500 events (*Extractor and *ExtractorRndm).
804 (They were simply exchanged in callisto.cc) This bug might have been
805 introduced in Mars 0.9.4 when the order of calculation of the two
806 types of pedestal in callisto got exchanged. The bug only effects
807 the first seconds of data of each sequence.
808
809 - star: Taking the arrival time of Muons into account the calculation
810 of the parameters could be made independant of the noise
811 (pedestal rms). The dependance was due to the bias of the peak search
812 extractor. Now only a ZA dependamcy is left which is not yet fully
813 understood.
814
815 - ganymed: The sequences were still not sorted correctly in any case,
816 because they were sorted by the full qualified path name. Now they
817 are sorted by their sequence number.
818
819 - ganymed: new values for the spark-event-cut
820
821 - sponde: required missing MEnergyEst from ganymed.root... fixed.
822
823
824
825 *** Version 0.9.4.1 (2005/08/18)
826
827 - callisto: fixed some problems with the calibration in case of
828 inteleaved events. Therefor the final and some intermediate
829 fits are skipped which would take place on partly filled #
830 histograms and gave wrong results or failed completely.
831
832 - callisto: If the intermediate finalization of the histograms
833 calculating the mean charge of the calibration signal fails
834 it is counted now and printed in PostProcess of MCalibCalcFromPast.
835
836 - ganymed: Fixed some bugs which caused problems in On-only mode.
837 Still the false source plot doesn't give reasonable results.
838
839
840
841 *** Version 0.9.4 (2005/08/05)
842
843 - general: Fixed the ZA binning. It did not correctly fit the
844 MC binning
845
846 - general: Added a class to correct for the missfocussing in
847 April (MSrcPosCorrect)
848
849 - general: Random Forest energy estimator should now work properly
850
851 - general: MHCamera now displays the profiles in deg instead of mm
852
853 - general: MH::SetPalette offers a lot of new palettes
854
855 - general: MHillas - the case of CorrXY==0 is now handled properly
856
857 - general: implemented the possibility to change the line and
858 marker style of a sky-grid drawn by MAstroCatalog
859
860 - general: Runs in sequences and datasets are now automatically
861 ordered (it is assumed that the order of their filenames correctly
862 represents the order of observations) to ensure correct reading
863 of the subsystem data
864
865 - general: Runs cannot be added to a sequence twice anymore. Also
866 Sequences cannot be added twice anymore to a dataset.
867
868 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
869 It gave wrong results by 1./2pi
870
871 - showplot: got a new option to start a root interpreter, too
872
873 - mars: now displays a rough estimate of Disp and the third moment
874
875 - mars: now displays the event time MTime if available
876
877 - mars: show muon parameters graphically
878
879 - mars: now the file to open can be given as commandline
880 argument
881
882 - merpp: Added support for new arehucas version >= 200507190
883 implementing values for three temperature sensors in the
884 counting house (MCameraAUX) and the name of the HV settings file
885 (MCameraHV).
886
887 - merrp: Also fixed some problems with wrong versions numbers stated
888 by arehucas and implemented some fixed for old versions (<200407070)
889
890 - callisto: MCalibrationHiLoCam can now be printed from its context
891 menu, eg in the TBrowser
892
893 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
894 - 1.39 (MExtractTimeAndChargeSpline)
895 - 1.40 (MExtractTimeAndChargeDigitalFilter)
896 This is important mainly for timing studies.
897
898 - callisto: Changed limits in MHCalibrationChargeCalc from
899 - -100.125 to -98 (fgChargeHiGainFirst)
900 - 1899.875 to 1902. (fgChargeHiGainLast)
901 - -100.25 to -99 (fgChargeLoGainFirst)
902 - 899.75 to 901. (fgChargeLoGainLast)
903 Introduced new limits:
904 - fgNumLoGainBlackoutLimit: 0.05
905 - fgLoGainBlackoutLimit: 3.5
906 - fgLoGainPickupLimit: 3.5
907
908 - callisto: The handling of automatic weights for the digital filter
909 has been improved. There are now new calibration weights special
910 for Monte Carlo calibrations.
911
912 - callisto: Updated Muon scale with latest results (1% difference
913 for most data, 5% for Mar/Apr'05)
914
915 - callisto: use a new criterium to exclude bad pixels: If the high-gain
916 was saturated and the blackout-events in the low-gain exceed the
917 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
918 This excludes those pixels which have a saturating high-gain
919 channel, but the low-gain switch does not switch often enough
920 to make the distribution reliable.
921
922 - callisto: fix a bug counting the number of saturated events. Up to now,
923 the number of saturated slices was counted (which is one for a not too
924 high number), but for some (pathological) pixels, many more slices
925 saturated and produced wrong limits.
926
927 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
928 + MCalibrationRelTimeCam.CheckFitResults: Yes
929 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
930 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
931 + MCalibrationRelTimeCam.CheckOscillations: Yes
932
933 - callisto: introduce max. number of events for intercalibration,
934 the rest gets skipped. Default: 4096
935 The calibration causes too many un-reliable pixels if more
936 than about 5000 events are treated (@500 Hz) because of the
937 mode hopping of the VCSels. However, in the past, some
938 calibration runs have been taken (erroneously) with more
939 than 5000 events, especially the intensity scans where
940 a good precision is needed.
941
942 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
943 photo-electrons for the spline extractor by 1-2% (correctly).
944
945 - callisto: The intercalibration is now done using a full f-factor
946 method instead of a simple update. This makes things slower but
947 more reliable in terms of gain-fluctuations and sudden VCSEL gain
948 changes.
949
950 - callisto: MPedestalY3 now uses the same extraction range as the data
951 as calculated by MPedestalY2
952
953 - callisto: A check of the fraction of allowed unsuitable (10%) and
954 unreliable (30%) pixels has been addded when the conversion is
955 calculated from interleaved events
956
957 - star: fixed a bug which caused MEffectiveOnTime containers not to
958 be written. In the worst case they were skipped almost all, in the
959 best case they were all ok. It depends on how often the new value
960 was assigned just with an event which was skipped later by another
961 task
962
963 - star: new histograms MHPointing and MHRate
964
965 - star: New tab (Currents) displaying the time evolution of the mean
966 DC currents
967
968 - star: New tab (MeanRms) displaying the time volution of the mean
969 Pedestal Rms
970
971 - star: Output now contains MReportStarguider
972
973 - star: Improved muon analysis. Due to the absense of a constant
974 for the gaus fit for arc width and the fact that the arcwidth
975 plot was a histogram instead of a profile the resulting psf
976 became pedestal rms dependant
977
978 - ganymed: added new plot (MHPhi) for wobble mode as described in
979 http://www.astro.uni-wuerzburg.de/results/ringmethod/
980
981 - ganymed: corrects now (correctly?) for the misspointing in
982 May/April 05
983
984 - ganymed: Two new default templates for ganymed.rc are avilable:
985 ganymed_onoff.rc and ganymed_wobble.rc
986
987 - ganymed: The first version of MFMagicCuts has been released
988
989 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
990
991 - ganymed, sponde: There are two new options to determin the number
992 of bins for the signal region (NumBinsSignal) and the number of
993 total bins (NumBinsTotal) in the MHThetaSq histogram
994
995 - ganymed: optimized palettes for MHDisp
996
997 - ganymed: Fixed an important bug when using ThetaSq as fit function:
998 The result for the sigma of the gauss(sqrt(x)) fit was a factor
999 sqrt(2) to large
1000
1001 - ganymed: The false source plot (MHDisp) is now based on Disp
1002 and a background model determined in the first loop is
1003 subtracted
1004
1005 - ganymed: MFMagicCuts are now available in the cvs. The correct
1006 solution for the disp ambiguity problem is now calculated using
1007 the third moment. The third moment cut therefor is skipped.
1008
1009 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1010 already determined by the third moment along the major axis and
1011 so its actual sign is aligned along the major axis of the shower.
1012
1013 - ganymed: If starguider data is available it is taken into account
1014 when calculating the source position. This is especially important
1015 for wobble data at high zenith angles and culmination data.
1016
1017 - ganymed: If available the starguider data is taken into account as
1018 good as it is possible without a starguider calibration. To switch
1019 it off add
1020 MPointingDevCalc.MaxAbsDev: -1
1021 to your ganymed.rc
1022
1023 - sponde: the zenith angle distribution is now weighted instead of
1024 choosen by default. This gurantees higher statistics in the highest
1025 and lowest energy bins. To switch this behaviour off use...
1026
1027 - sponde: now automatically displays the energy threshold
1028
1029
1030
1031 *** Version 0.9.3 (2005/06/03)
1032
1033 - general: MMcEvt now derived from MMcEvtBasic which should
1034 have no influence on compatibility with older camera files
1035
1036 - general: Implemented a new option to MReadReports which allows
1037 to force reading of the first event of some trees (eg. Drive-tree)
1038 before any other tree.
1039
1040 - general: Made a fix to MPointingPosCalc which assumes that the
1041 run-type is real-data if Process is called before ReInit, such
1042 that also the very first Drive-events in a run are treated
1043 correctly.
1044
1045 - shoplot now displays the filename in the title bar of the window
1046
1047 - merpp: new options: --auto-time-start --auto-time-stop which
1048 allow to cut updating with slow-control at the start- or
1049 (previousle --auto-time only allowed: and) stop-time of
1050 the run stored in the runheader.
1051
1052 - callisto: changed default of fgFallTimeHiGain in
1053 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1054 already set as default in callisto_Dec04Jan05.rc
1055
1056 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1057 now changes the filename for new weights automatically for
1058 cosmics, MC and for different calibration colors.
1059
1060 - callisto: a problem with the order of some code cause the
1061 name of the weights file in MPedestalY2 to be ignored.
1062 Wrongly the calibration_UV weights were used instead
1063 of the cosmics weights set in callisto.rc.
1064
1065 - callisto: should allow ct1 pulser data when the color is
1066 explicitly set also for pretty new runs
1067
1068 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1069 to introduce an additional scale factor (should be around 1)
1070 to adapt for slight deviations in different extractors from
1071 the MC calibration. For MC calibrations the scale factor
1072 is fixed to 1
1073
1074 - callisto: MFCosmics should handle very high signals a bit
1075 more accurate now
1076
1077 - callisto: when calculating the mean pedestal rms for different
1078 pixel sizes or sectors also kUnsuitableEvt is now taken into
1079 account - not only kUnsuitableRun
1080
1081 - callisto: '-raw' option is now the default
1082
1083 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1084 This has the advantage that mean values in the calibration (eg
1085 arrival times) are calculated more accuratly.
1086
1087 - callisto: In the resource file callisto_Dec04Jan05.rc
1088 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1089
1090 - callisto: new Hi-/Lo-Gain intercalibration constants
1091 hilocalib_sp1.root and hilocalib_sp1_mc.root
1092
1093 - callisto: changed default for MJPedestalY2.MaxEvents
1094 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1095
1096 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1097 has changed from 9.0 to 6.0. This is necessary to exclude two very
1098 ringing pixels in September which - when kept - destroy the image
1099 cleaning around them (Markus G.)
1100
1101 - callisto: (!) The Muon analysis of all data taken so far has
1102 suggested that different extractors give slightly different
1103 absolute results after calibration, due to there different
1104 handling of the calibration- and cosmics pulse shape. Although
1105 the over all calibration seems to be a bit to pesimistic (or
1106 the MC seems to be a little bit - 3-5% - too much attenuated).
1107 There for correction factors have been introduced which correct
1108 the calibration constants by
1109 0.956937799 for Digital Filter (callisto.rc)
1110 and
1111 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1112 calibration. The main advantage is, that both data types can
1113 be easily analysed together and compared to the same MC sample.
1114 The factors are choosen such, that the reference is now a
1115 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1116
1117 - star: fixed a bug which caused the first bin of the histograms
1118 vs time to disapear in PostProcess. This gave wrong results
1119 on the screen. The output and all following programs not
1120 directly accessing the histograms haven't been affected
1121
1122 - star, ganymed: Made sure that always the first Drive-tree event
1123 is read and Processed before the first data event was read.
1124
1125 - ganymed: implemented the possibility to replace the standard
1126 false source plot with a different one. For example: If
1127 you want to use a Disp based FS plot use the resource:
1128 NameHistFS: MHDisp
1129 For details about the requirements of these plots look
1130 at the corresponding classes
1131
1132 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1133 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1134 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1135 case MAlphaFitter is setup correctly. For On-Only optimization
1136 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1137 RunOn() instead of Run(). For energy estimation MJOptimize
1138 has been replaced by MJOptimizeEnergy
1139
1140 - sponde: The input MC spectrum can now be weighted to fake a
1141 different spectrum. This is done via MMcSpectrumWeight. For
1142 more details see the class description and sponde.rc
1143
1144 - sponde: The paremeter comparsion plots are not scaled by
1145 their entries anymore. Instead the MC plot is scaled by using
1146 the result spectrum of the analysis. If the input MC spectrum
1147 and the result spectrum has different slopes the absolut
1148 normalization is normally wrong.
1149
1150
1151
1152 *** Version 0.9.2 (2005/05/20)
1153
1154 - general: Changed the default paths for calibrated data and image
1155 files. (The implemented access to these files doesn't yet exist)
1156
1157 - general: support for MRunIter has been removed from the job classes
1158 (use the setter functions of MSeqeunce instead)
1159
1160 - general: ProcessFile has been renamed to Process in all job classes,
1161 because ProcessFile is missleading
1162
1163 - general: The storage of the palette in MHCamera is now possible
1164
1165 - general: new bits describing unsuitable and unreliable pixels have
1166 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1167 kDeadPedestalRms, kFluctuatingArrivalTimes
1168
1169 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1170 versions newer than V200404070
1171
1172 - general: support for cc file versions newer than V200504130. Added
1173 support for active loads (MCameraActiveLoad) and central pixel
1174 (MCameraCentralPixel)
1175
1176 - general: added new histograms for image parameters versus size
1177 (MHVsSize)
1178
1179 - general: The eventloop now automatically calls PrintStatistics
1180
1181 - Status Display: Improved support for printing:
1182 + A default can now be set in .rootrc (for more details see
1183 MStatusDisplay::PrintPS)
1184 + A print dialog is opened so that printer and command line
1185 can be canged
1186
1187 - showlog: improved such that it handles different verbosity levels
1188 more accurate now. This mean you can suppress output when
1189 using showlog.
1190
1191 - showplot: improved
1192 + The new graphics formats have been implemented
1193 (pdf, svg, png, jpg and xpm)
1194 + Implemented an interface for printing. Because you can change
1195 the printing command from the command line you can use all
1196 the nice postscript tool. To print a booklet for example call:
1197 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1198 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1199 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1200
1201 - callisto: fixed a bug in the recognition of the calibration bit
1202 pattern. Concerns only intensity calibration. (The strength of the
1203 intensity has been updated in some cases)
1204
1205 - callisto: add a filter against PIN Diode events when running over
1206 calibration runs since some of the recent calibration runs have
1207 been taken with Pin Diode.
1208
1209 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1210 39943, 44833 in the calibration (MCalibColorSet)
1211
1212 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1213 been set to 1e-18 in callisto_Dec04_Jan05.rc
1214
1215 - callisto: in callisto_Dec04Jan05.rc: set value for
1216 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1217 statistics for the calculation of the mean pulse time
1218 of the cosmisc
1219
1220 - callisto: the charge limit in the calibration has been raised
1221 from 2.5 to 4.5
1222
1223 - callisto: new setup read from callisto.rc
1224 + MCalibCalcFromPast.fNumEventsDump
1225 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1226 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1227
1228 - callisto: MExtractTimeAndChargeSpline extractor:
1229 + The integration ranges were shifted by 0.2 FADC slices to the right.
1230 + unreliable handling of floating point values caused different
1231 results on different platform or with different compiler options:
1232 The new algorithm is numerically exact and more accurate because
1233 it doesn't calculate the integration position by multiple times
1234 adding the step-size (which results in numerical uncertanties
1235 exspecially if multiplied with large numbers)
1236 + A lot of fixes have been introduced which effects integrating the
1237 spline at the edges of the valid range. In this case any memory
1238 was randomly accessed. This behaviour can be tested replacing
1239 all MArrayF by TArrayF which perform a range check (but of course
1240 they are a lot slower)
1241 ! No result obtained with the Spline before can be trusted! Due to
1242 random memory access it might by completely random!
1243
1244 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1245 + extraction range in the high gain to 4.
1246 + weights file to cosmics_weights46.dat
1247
1248 - callisto:
1249 + introduce the check for fluctuating arrival times.
1250 + set charge limit to from 2.5 to 4.5
1251 + introduce asymmetric exclusion due to "deviating number of phes":
1252 Default: -9.0 +4.5
1253 + make deviating number of phes unsuitable (see David's findings).
1254
1255 - callisto: fixed the display of unsuitable pixels. The old change
1256 to a real profile in MHCamera broke it.
1257
1258 - callisto: The cosmics filter is used in MJCalibration now
1259 independant of the pulser color (formaly it was used only for
1260 CT1-pulser data). The threshold of number of max empty pixels
1261 has been raised from 2% to 5% in MJCalibration. The maximum
1262 fraction of rejected event is 50% otherwise the calibration has
1263 failed. The filter now ignores unsuitable pixels.
1264 Setup the filter from callisto.rc using "ContCosmics"
1265 (see MFCosmics::ReadEnv)
1266
1267 - callisto: changed default for fgOffsetFromLogain back
1268 from -2.8 to -1.8 in digital filter.
1269
1270 - callisto: for the common extractors
1271 + MExtractFixedWindow
1272 * MExtractTimeAndChargeSlidingWindow
1273 * MExtractTimeAndChargeSpline
1274 * MExtractTimeAndChargeDigitalFilter
1275 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1276 and fResolutionPerPheLoGain
1277
1278 - callisto: Updated the hi-/lo-gain intercalibration constants
1279 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1280 hilocalib_df6.root
1281
1282 - callisto: The default lo-gain extraction window for the
1283 MExtractTimeAndChargeSlidingWindow extractor has been increased
1284 from 6 to 8 to take the stretch of the pusle into account
1285
1286 - callisto (!!!): fixed an important bug in the setting of the
1287 incoming pedestal pointer to the signal extractor extracting
1288 pedestals. This bug caused the pedestals not to be subtracted
1289 correctly in the calibration afterwards. The effect was about 10%
1290 too high conversion factors for the digital filter and the spline
1291 and more than 40% for the sliding window.
1292 The bug existed since end of February! (Markus G.)
1293
1294 - star: added muon support to star. A new tab "MHMuonPar" is
1295 displayed. The lower right plot is an estimate of the point spread
1296 function. A reference value is displayed. To get the real PSF
1297 you must compare with MC. The setup for the muon analysis
1298 is done in star.rc. More informations can be found in
1299 MHSingleMuon and MHCalibParCalc
1300
1301 - star: The weather data is now displayed in star
1302
1303 - star: MEventRateCalc handles the calculation of the event rate more
1304 accurate now in case of the start of a new run inside a sequence
1305
1306 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1307 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1308 changed only minimally
1309
1310 - ganymed: (MJCut and MJOptimize) now displayes the number of
1311 excess events versus size. The energy estimation is done in
1312 MJSpectrum (sponde)
1313
1314 - ganymed: got support for using other variables than Alpha, eg. Theta.
1315 Therefor you need a class deriving from MHAlpha which supports
1316 this variable (one is already existing: MHTheta, which is now the
1317 default in ganymed). It is setup through ganymed.rc
1318
1319 - added a full featured spectrum program (sponde) which reads
1320 ganymed output and monte carlos and compiles a spectrum
1321
1322
1323
1324 *** Version 0.9.1 (2005/04/14)
1325
1326 - Fix bug on the arrival time reconstruction when using Digital
1327 Filter (in some marginal cases (10%) times were reconstructed shifted
1328 by 0.2 slices)
1329
1330 - all executables now return 2 where in previous versions -1 has
1331 been returned (gave problems with shell-scripts)
1332
1333 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1334 also done with a intercalibration input file
1335
1336 - a bug in the time fine adjustment of the digital filter has been fixed
1337
1338 - a lot of small fixes to calling TPad::Divide with a margin==0
1339
1340 - MStatusDisplay now shows the memory usage
1341
1342 - added a memory leak statistic after the eventloop
1343
1344 - MHadronness replaced by MParameterD
1345
1346 - MEnergyEst replaced by MParameterD
1347
1348 - wobble mode can now be switched on from the data-set
1349
1350 - switched on bad pixel detection for a pedestal level
1351 which is more than 5 times the variance
1352
1353 - Fixed default paths to be correct for the new data center
1354
1355 - Fixed handling of drive data. The pointing position in now
1356 copied to MPointingPos inside star for real and MC events
1357
1358 - made sure, that the sequences in a dataset are sorted by
1359 their number to ensure the correct synchronization
1360
1361 - added all resource files necessary to handle spline extraction
1362 of signal for the late 2004 and the early 2005 data
1363
1364 - update the reference lines for the december data
1365
1366 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1367 This is important for the Dec. and Jan. data where the calibration
1368 pulse position changes much.
1369
1370 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1371 filter. This corrects only an defective extraction of the MC at
1372 low-gain signals lower than 90 phes.
1373
1374 - fixed some slowdown in calibrating data with interleaved events from
1375 Jan and Dec. As a workaround made the pretty palette the default.
1376 The inverse Deep Blue Sea has a bug which slows down long calibration
1377 runs a lot.
1378
1379 - implemented new values from new starguider report as defined
1380 in TDAS00-07 V7.1 (eg SkyBrighness)
1381
1382 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1383 in starguider report (If you merpp the same reports with this version
1384 you'll get the correct units (arcmin) but a different result
1385 than with old versions (wrong units))
1386
1387 - Now the status display can also write PNG, JPEG and XPM (other file
1388 formats are still unsupported by root)
1389
1390 - added a lot of scripts and macros in directory datacenter used
1391 for automatic processing
1392
1393
1394
1395 *** Version 0.9 (2005/03/23)
1396
1397 - Calibration is now done autmatically into photo-electrons like
1398 decided by the Collaboration Board
1399
1400 - Reference lines in the display can be read from resource file
1401
1402 - Interlaced calibration events can be handled by callisto
1403
1404 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1405 and applied in callisto.
1406
1407 - class MJCalibTest can be called by callisto
1408
1409 - callisto can now run with three data types: rawdata, rootdata, MC
1410
1411 - added two classes mreport/MReportStarguider.cc and
1412 mreport/MReportStarguider.h for implementing starguider-data
1413
1414 - the output of merpp-update now contains starguider information:
1415 MReportStarguider and MTimeStarguider
1416
1417 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1418 values were lower than they should. This was more visible for high
1419 energy (Size) events.
1420
1421 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1422
1423 - added a new loop to callisto to support the correct extraction of
1424 the pedestal and pedestal rms through the signal extractor
1425
1426 - added class to perform fourier tranformation of a hexagonal structure
1427 (MHexagonalFT)
1428
1429 - added class to perform fourier tranformation of a hexagonal structure
1430 in a tasklist (MHexagonalFTCalc) example: hft.C
1431
1432 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1433 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1434 small pixels, example: extendcam.C
1435
1436 - added possibility to write data to memory (TTree) using MWriteRootFile
1437
1438 - added possibility to read a TTree stored only in memory by MReadTree
1439
1440 - new classes to deal with the interleaved calibration events:
1441 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1442
1443 - implemented filters to callisto to skip calibration events
1444
1445 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1446 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1447 the slices by statistics
1448 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1449 signal extractor without randomization
1450 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1451 with the signal extractor with randomization (extraction window is
1452 randomly fixed)
1453 The three kind of pedestal is not yet implemented (for speed reasons) as
1454 long as nobody really needs it:
1455 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1456 extracted with the signal extractor with randomization
1457
1458 - callisto now finds the pulse position in the data automatically
1459
1460 - implemented data reduction in calibrated data by reducing the precision
1461 of the stored floating point values (pedestal, rms and signal) to
1462 roughly 0.5%
1463
1464 - fixed showplot to make file format conversion (eg. converting a
1465 status display stored in a root file into a postscript file) in
1466 batch mode possible:
1467 showplot -b --save-as-ps[=outfile.ps] infile.root
1468
1469 - Allow class names as part of filter rules, eg
1470 (MFSupercuts) && (MHillas.fSize>100)
1471
1472 - fixed a lot of stuff to allow all programs to process MonteCarlo
1473 camera files.
1474
1475 - enhanced possibility to debug reading of resource file
1476
1477 - MDataChain should handle priorities of operator more
1478 accurate now
1479
1480 - completely revised the container in which the signal is stored
1481 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1482 * the new implementation is faster and
1483 * needs less storage space
1484
1485 - FIRST version which can process Monte Carlos through the
1486 whole chain of programs (callisto, star, etc)
1487
1488 - implemented new image parameters for the border length of
1489 the shower image (MNewImagePar2)
1490
1491 - implemented wobble-mode in ganymed
1492
1493 - new class (MJOptimize) taking care of all optimization processes
1494
1495
1496
1497 *** Version 0.8.6 (2004/10/05)
1498
1499 - New combined signal and time extractor
1500 MExtractTimeAndChargeDigitalFilter
1501
1502 - The Report for the trigger section in the CC run summary has been
1503 updated, and now the IPRs (Individual Pixel Rates) are available.
1504
1505 - new macros for database interaction: filldotrun.C, filldotrbk.C
1506
1507 - added new program which can convert colored output which was redirected
1508 into a file back into colored text (for example to display it with
1509 more): showlog
1510
1511 - added new program to display an MStatusArray of plots (stored with
1512 MStatusDisplay) from a file: showplot
1513
1514 - Added support for Sequences (MSequence). Sequences are blocks of run
1515 files containing the same calibration and belonging to the same
1516 source
1517
1518 - Added a new task (MTaskEnv) which can be used in setup files to switch
1519 between different tasks (for example to choose a signal extractor)
1520
1521 - Implemented automatic file splitting in MWriteRootFile
1522
1523 - After image cleaning an island index is assigned to all used pixels.
1524 The index corresponds to the order of the islands in size.
1525
1526 - added a cleaning which takes signal height _and_ arrival time into
1527 account: probability cleaning (for more details see MImgCleanStd)
1528
1529 - added a cleaning which takes takes the absolute number of photons
1530 times the area ratio as cleaning level
1531 (for more details see MImgCleanStd)
1532
1533 - Changed calculation of image parameters such, that it can be done
1534 for all used pixels or the pixels with a defined island index only
1535
1536 - implemented new image parameters displaying the number of islands,
1537 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1538
1539 - event display in executable changed to support also calibrated files
1540 (done with MJCalibrateSignal)
1541
1542 - added program doing the calibration and the signal extraction
1543 and signal calibration: callisto Most part of the setup is done
1544 by a resource file: callisto.rc
1545
1546 - implemented support for pixels with negative IDs (Raw file format
1547 version 4)
1548
1549 - implemented an new option in merpp (--auto-time) to get the time
1550 range for cc and/or caco data from the run header of the raw data
1551
1552 - New star-program (star and MJStar). Taking calibrated data from
1553 callisto/MJCalibrateSignal as input. The setup is done through
1554 a resource file: star.rc
1555
1556 - Added possibility to setup the eventloop in the mars-executable
1557 Camera Display by a resource file: mars.rc
1558
1559 - The the mars-executable Camera Display can now also read
1560 calibrated data files written by callisto/MJCalibrateSignal
1561
1562 - Added a new class which can calculate the source position in
1563 the camera from a pointing model known to be correct and
1564 the pointing model used for observations (MSrcPosFromModel)
1565
1566 - added a new version of the class calculating the effective on-time
1567 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1568 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1569 MHTimeDiffTheta.
1570
1571 - added the possibility to count how often a signal is above (or
1572 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1573 can replace MHTriggerLvl0)
1574
1575 - added ore convinient ways to set the axis-titles of your histograms
1576 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1577 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1578
1579
1580
1581 *** Version 0.8.5 (2004/08/06)
1582
1583 - new Signal Extractors: MExtractFixedWindowSpline
1584 and MExtractAmplitudeSpline
1585
1586 - implementes interleave in merpp to be able to merpp parts of a file
1587
1588 - implemented force-functionality to merpp
1589
1590 - star display to display star catalogs (MAstroCatalog)
1591
1592 - star display to 'mirror' stars to the camera (MAstroCamera)
1593
1594 - implemented a new cleaning option which allows cleaning scaled with
1595 the real ratio of the rms depending on the pixel size, not only the
1596 square root of the pixelsize (MImgCleanStd, MCameraData)
1597
1598 - removed obsolete MBlind* classes
1599
1600 - Signal extractor taking the AB flag into account implemented (this makes
1601 an odd number of slices for signal extraction possible
1602 (MExtractSignalABcorr)
1603
1604 - implemented a class extracting the pedestal from the raw-data (events)
1605 itself using empty lo-gain (MpedCalcFromLoGain)
1606
1607 - Added mean values to MPedPhotCam
1608
1609 - Added Makefile for Darwin (this OS is NOT officially supported!)
1610
1611
1612
1613 *** Version 0.8.4 (2004/04/19)
1614
1615 - new fast arrival time extractor using cubic splines:
1616 MExtractTimeFastSpline
1617
1618 - implementes multi-argument support in MDataChain
1619 ("pow(a, b)")
1620
1621 - implemented double reference support in MDataChain
1622 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1623
1624 - added support in MF for expressiond like
1625 "MHillas.fWidth<2*<MHillas.fLength"
1626
1627 - MDataChain is now able to support variables like [0], [1], ...
1628 which can be used in fit functions as parameters. The interface
1629 is implemented through the new virtual function
1630 MParContainer::SetVariables
1631
1632 - added new class MArrivalTimeCam/MArrivalTimePix:
1633 Storage containers to hold the ArrivalTime of the camera/pixel
1634
1635 - added new classes for the calibration of relative arrival times:
1636 MCalibrationRelTimePix and MCalibrationRelTimeCam
1637
1638 - added new classes to extract the signal of the blind pixel and the
1639 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1640
1641 - added new classes for the bad-pixels treatment (MBadPixels*)
1642 which are more powerfull than the old ones (MBlindPixel*)
1643 and will replace them.
1644
1645 - added filter against cosmics: MFCosmics
1646
1647 - added new class MArrivalTimeCalc2:
1648 Calculates the arrival time as the signal weighted mean of the time
1649 slices in the maximum window
1650
1651 - added a new macro call pointspreadfucntion.C that fits with a 2D
1652 gaussian the DC spot for an star. It gives you the RMS of
1653 the PSF and the center of the star, very useful for misspointing
1654 studies.
1655
1656 - added support for multi-telescope camera files. Added classes
1657 MStereoCalc and MStereoPar, classes to calculate and store shower
1658 parameters calculated from the data of two telescopes, for the MC
1659 studies regarding the MAGIC clone.
1660
1661 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1662 MC data calibrated in photons instead of ADC counts.
1663
1664 - added three macros to show the calibration and analysis chain of
1665 MC data. The macro starmc.C does both calibration and analysis, producing
1666 an output containing Hillas parameters for each event. The macro
1667 mccalibrate.C does just the calibration and writes out a file containing
1668 pixel information in photons instead of FADC data. The macro starmc2.C
1669 reads in such a file and produces an output with Hillas parameters.
1670
1671 - added MPedPhotCalc to compute pedestals in units of photons, see
1672 macro pedphotcalc.C
1673
1674 - added all class to perform the calibration, see macro calibration.C
1675
1676 - added class MFFT to perform Fast Fourier Transforms
1677
1678 - added class MSimulatedAnnealing to perform simulated annealing
1679 minimizations
1680
1681 - added new macro bootcampstandardanalysis.C which holds the skeleton
1682 of the analysis chain discussed in the december bootcamp.
1683
1684 - added support for DAQ raw data file format V2
1685
1686 - implemented an arbitrary time stamp for the events from raw-data
1687 files with file version<3. It is calculated from the run number,
1688 the date of start and the FADC clock tick from the first module
1689
1690 - implemented the correct decoding of the event time-stamp
1691 coming from the DAQ for raw-data files with file-version>2
1692
1693 - added a new classes storing the pedestals in units of photons:
1694 MPedPhotPix, MPedPhotCam
1695
1696 - added support for DC current files from the camera control
1697
1698 - added support for start- and stop-time when merpping report files
1699
1700 - added MReportCC storing the weather data from the CC-REPORT
1701
1702 - added class to fill trainings and test matrices (MTFillMatrix)
1703
1704 - added a filter performing a software trigger (MFSoftwareTrigger)
1705
1706 - Added classes to perform parts of the standard analysis (Jobs):
1707 + MJPedestals
1708 + MJCalibration
1709 + MJExtractSignal
1710 Note: All of them are preliminary!
1711
1712 - Added Iterator to iterate over files giving only the run-number
1713
1714 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1715 the evolution of a sector vs time
1716
1717
1718
1719 *** Version 0.8.3 (2003/12/05)
1720
1721 - adapted Random Forest classes to allow the use with MC
1722 multi-telescope files which can be produced with the coming
1723 camera version 0.7.
1724
1725 - added classes to read and interprete central control report files
1726 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1727
1728 - enhanced merpp (the executable) to support .raw and .rep files.
1729
1730 - added classes for light calibration (MCalibration* and
1731 MHCalibration*) by Markus Gaug. Further work has to be and will
1732 be done soon.
1733
1734 - Added a preliminary 'synchronizer' (MReadReports) which will
1735 replace MReadMarsFile as soon as it is finished.
1736
1737 - Added a tutorial macro demonstrating how report files are merpped
1738 and how they can be read from the root file in the correct order
1739 of time (readrep.C)
1740
1741 - Added a generalized histogram (similar to MH3) called MVsTime
1742 which allows to plot variables (or rules - MDataChain - of
1743 variables) vs time. For an example have a look at tempvstime.C.
1744
1745 - Changed the name of the event trees:
1746 + Events --> Events
1747 + PedEvents --> Pedestals
1748 + CalEvents --> Calibration
1749
1750 - changed name of MTime in the event trees from MRawEvtTime to MTime
1751
1752 - added displaying the sector indices to the mars event display
1753
1754 - Magic Online Analysis (MOnA) implemented in a first version
1755 (see mona.cc, MOnlineDump and MOnlineDisplay)
1756
1757 - added classes to calculate event rate
1758 (preliminary: MEventRateCalc, MEventRate)
1759
1760 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1761
1762 - added classes dealing with the telescope pointing position (MPointing*)
1763
1764 - implemented the 'final' Mars time stamp based on some experiences with
1765 the new 'Synchonizer'
1766
1767
1768
1769 *** Version 0.8.2 (2003/11/10)
1770
1771 - accelerated standard analysis by a factor of 6-8 ...
1772 + doing precalculations in MGeomCam for the pixel area ratio
1773 + creating a look up table for the single pixels in MCerPhotEvt
1774
1775 - added task to calculates weights in case you want to 'change'
1776 the energy spectrum of a monte carlo file
1777 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1778
1779 - added a new executable star which implements the
1780 star.C macro as precompiled executable. Currently a flexible
1781 setup is not possible, but a 'input card' setup will follow.
1782
1783 - Starting to implement Multi-Telescope-Support based on the
1784 upcomming camera version 0.7. The base for a general support
1785 is implemented and the star-functionality is proven to work.
1786
1787 - Replaced Event-Display in and Camera-Display in the Mars GUI
1788 executable by a more convinient display base on MStatusDisplay.
1789
1790 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1791
1792
1793
1794 *** Version 0.8.1 (2003/10/20)
1795
1796 - added signal subtraction for pure on data by means of fitting
1797 the background in the off region or by performing a combined
1798 signal/background fit. Provides necessary histograms for
1799 obtaining energy spectra and a light curve.
1800
1801 - added classes to perform and study the selection of the
1802 2nd Level Trigger on MC data (example in triglvl2.C macro)
1803
1804 - added pedestal calculation
1805
1806 - implemented "democratic cleaning" (tail cut value proportional
1807 to pixel area) according to Wolfgang's suggestion.
1808
1809 - added Sigmabar treatment (calculation and basic histogramming)
1810
1811 - added basic routines to apply padding
1812
1813 - added first implementation of MARS-based source visibility plotter
1814 (needs to be linked against slalib, preliminary version)
1815
1816 - enhanced functionality of data chains: random numbers, conversion
1817 functions and access to MHMatrix objects
1818
1819 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1820 numbers under certain circumstances (runs with 0 events included)
1821
1822 - fixed a bug in the general filter MF (didn't work on some systems
1823 at all)
1824
1825 - fixed a bug in chaining files, which caused the analysis to crash or
1826 ignore files
1827
1828 - implemented more geometry classes describing the parameters used
1829 to simulate the PMT camera
1830
1831 - added new Monte Carlo classes containing the setup of the different
1832 programs in the MC chain.
1833
1834 - added a (preliminary) general task to evaluate chi-square of a given
1835 parameter in an eventloop.
1836
1837 - first implementation of a container describing the observatory
1838 location (Long, Lat, etc)
1839
1840 - added Random Forest - method for g/h-separation
1841
1842 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1843 (this means, that it is compiling, but not yet fully tested)
1844
1845 - added a new status display which can show the present status
1846 of histograms while an eventloop is running (MStatusDisplay,
1847 an example can be found at status.C)
1848
1849 - reorganized directories:
1850 classes describing the image --> mimage
1851 classes containing Monte Carlo Histograms --> mhistmc
1852 classes for Random Forest method --> mranforest
1853
1854 - added (event-)weights to fill histograms
1855
1856 - colors in logging output to screen
1857
1858 - changes to the Image Parameter declaration:
1859 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1860 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1861 + MHillasExt now derives from MParContainer instead of MHillas
1862 --> Files written with the old definition are more or less unreadable
1863
1864 - reading of reflector files
1865
1866 - display data from reflector files in the camera
1867
1868 - implemented currents (and display them in the camera)
1869
1870 - logarithmic scale in camera
1871
1872 - added class to iterate through directory contents (MDirIter)
1873
1874
1875
1876 *** Version 0.8 (2002/11/18)
1877
1878 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1879
1880 - corrected 48(!) wrong entries in the Next Neighbor table of the
1881 Magic Camera (all in the inner part of the outer ring, mostly
1882 missing a single NN)
1883
1884 - Fixed a bug in the table describing the Next Neighbours of the
1885 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1886 have any neighbour)
1887
1888 - changed trigrate.C: now it calculates the pure NSB triggers from
1889 a camera file (generated with no showers), so there is no need
1890 to introduce them by hand in the BgR array (for more details
1891 please ask Abelardo)
1892
1893 - added MHHadronness (and MHadronness) as a general facility to evaluate
1894 the quality of a gamma-hadron seperation method
1895
1896 - changed MWriteAsciiFile to accept rules (MDataChain)
1897
1898 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1899 must be replaced by calles to MWriteAsciiFile::AddColumn and
1900 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1901 changed.
1902
1903 - Implemented generalized event-matrices (one row per event)
1904 (MHMatrix)
1905
1906 - implemented the one dimensional composite probabilities
1907 (MHCompProb, MCompProbCalc, comprob.C)
1908
1909 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1910 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1911
1912 - Added a camera display displaying the pixel numbers to the
1913 event display gui.
1914
1915 - Added Monte Carlo Informations to event display gui
1916
1917 - Changed the camera display to display the pixel numbering
1918
1919 - Added three buttons to the camera display to change the palette
1920
1921 - Added the number of used and core pixels after image cleaning
1922 to MHillas
1923
1924 - Changed the algorithm used in MHillas according to TDAS 02-03
1925
1926 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1927
1928 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1929
1930 - Added fCosDeltaAlpha to MHillasSrc
1931
1932 - The numbers of photons used to calculate fConc and fConc1 in
1933 MHillasExt are now scaled with the pixel size, so that one get
1934 a four times smaller value for the bigger pixels in the outer ring.
1935
1936 - added new task to smooth the camera contents (MCameraSmooth)
1937
1938 - added possibility to use interpolated pixel values for blind pixels
1939 instead of removing it completely from the analysis
1940
1941 - Implemented the possibility to save the whole eventloop with
1942 its setup to a file. This information can be read and from
1943 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1944 and MEvtLoop::MakeMacro. If you find something not working, please
1945 report - this stuff is still in a beta phase.
1946
1947 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1948 file having crab starfield, but also for all following files - fixed
1949
1950 - MTaskList::PrintStatistics can now be instructud to print also the
1951 title, too: use PrintStatistics(0, kTRUE)
1952
1953 - Changed the image cleaning so that pixels with to many 'used'
1954 neighbors are left used (to get rid of 'holes' in events)
1955
1956 - Introduced more output to the camera displays
1957
1958 - Added an array of histograms (eg one hist per run), MHArray
1959
1960 - Added a _preliminary_ version of the reader for CT1 PreProc files
1961 (MCT1ReadPreProc)
1962
1963 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1964 (thanks to Raquel)
1965
1966 - added the first energy estimator (MEnergyEstParam, estimate.C,
1967 estfit.C) using a parametrization
1968
1969 - Added some new Monte Carlo paremeter containers used to store
1970 setup information from the MC chain (MMcConfigRunHeader,
1971 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1972
1973
1974
1975 *** Version 0.7 (2002/04/30)
1976
1977 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1978 the pedestal mean value was saved incorrectly. For files from
1979 this versions we substract 0.5 from the pedestal mean.
1980 WARNING: This may effect your results, so don't wonder...
1981
1982 - First implementation of an algorithm using only triggered events
1983 for the collection area calculation
1984
1985 - Ascii Output can now also be used for parameter containers which
1986 doesn't overload MParCointainer::AsciiWrite
1987
1988 - The Ascii Output is now also capable of writing single data members
1989 of one container
1990
1991 - You are now able to change the order of the values written to the
1992 ascii file
1993
1994 - You can now specify a conversion factor for each data member written
1995 to an ascii file. This may be usefull to change the units of the
1996 data member (eg. degrees instead of millimeters in case of the
1997 hillas parameters)
1998
1999 - Replaced old MHillas by a new structure which allows you to extend
2000 the parameters stored in MHillas very easily:
2001 see MHillas and MHillasExt
2002
2003 - Added classes to handle source dependancy of image parameters:
2004 see MHillasSrc
2005
2006 - Added container (MBinning) to have a standard input for the binning
2007 in different histograms (eg. the Energy bins should be the same in
2008 all histograms)
2009
2010 - Changed Hillas histograms from mm to deg
2011
2012 - Added the flexible binning to the hillas histograms
2013
2014 - Added a filter for the alpha parameter (MFAlpha)
2015
2016 - It is now possible to write single data members of a class object to
2017 an output stream instead of the whole container only
2018
2019 - Added a generalized filter for a data member:
2020 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2021
2022 - Added a generalized Filter parser for more difficult filter rules
2023 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2024
2025 - Added new Monte Carlo histograms:
2026 MHMcEnergyImpact and MHMcEfficiency
2027
2028 - Added many new histograms needed for the flux calculation.
2029
2030 - Added a generalized histograms which can fill and show up to three
2031 data members in either a one-, two- or three-dimensional histogram, eg:
2032 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2033
2034 - Added:
2035 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2036 * calculation of <Theta> as a function of time (MHThetabarTime)
2037 they are needed in the flux calculation in
2038 order to select for a given bin in Theta (or time) the appropriate
2039 effective collection area, which is assumed to be given as a function
2040 of Theta and the true energy
2041
2042 - Added calculation of the migration matrix in the energy
2043 (MHMcEnergyMigration):
2044 the migration matrix describes the migration from the true (E_true)
2045 to the estimated energy (E_est); it is needed to determine the
2046 distribution of E_true from the measured distribution of E_est
2047 by unfolding
2048
2049 - changed the color palette in the camera display to DeapSea.
2050
2051
2052
2053 *** Version 0.6 (2002/01/15)
2054
2055 - Introduce the option of disable pixels (MBlindPixels and
2056 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2057 able to deal with Star Field NSB.
2058
2059 - Fixed a bug in the pedestals substraction
2060
2061 - Introduced verbosity levels
2062
2063 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2064
2065 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2066 work correctly (thanks to Abelardo)
2067
2068 - Introduced correct treatment of the diffuse Night Sky Background
2069 and NSB (MMcPedestalNSB)
2070
2071 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2072
2073 - Introduced MMcRunHeaders which contains monte carlo run informations
2074
2075 - Added a 'Print'-Task (MPrint) which calls the Print function
2076 of a parameter container for each event
2077
2078 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2079
2080 - changes to be more efficient with root 3.02/06
2081
2082 - root 3.02/06 fixes:
2083 + the memory leak when reading MRawEvtData
2084 + loosing more time than necessary to update the progress bar
2085
2086 - MWriteAsciiFile is now capable of writing more than one container
2087 in a line. For example: To be able to write Monte Carlo and
2088 Hillas values (energy and alpha) in one line.
2089
2090
2091
2092 *** Version 0.5 (2001/11/06)
2093
2094 - Added new GUI functionality (Analysis)
2095
2096 - Added a camera display to be able to display events in the camera
2097 together with the calculated hillas ellipse
2098
2099 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2100 object at any state of the analysis, so that the output are several
2101 states
2102
2103 - Fixed a bug in the collection area error calculation
2104 (Thanks to Ciro and Abelardo)
2105
2106 - Fixed a bug which causes merpp to crash in some environments
2107
2108 - Implemented auto enabling scheme for Branches to speed up reading
2109 a lot (see MReadTree and MTask)
2110
2111 - Fixed a bug in the Histogram classes which caused histograms to
2112 be written to a file by MWriteRootFile without request
2113
2114 - changed the object I/O from the old stylish root I/O to the new
2115 'auto evolution scheme' This was done only for classes which are not
2116 yet used in Monte Carlo files, so that these files are still readable.
2117
2118 - Added support for a progress bar in MEvtLoop and MReadTree
2119 (see the Analysis Window in Mars for an example)
2120
2121 - Fixed a bug in the package creation which disturbed the conversion
2122 between a mars version unpacked from a tar file and the repository.
2123
2124 - Changed the code to writer merpped (converted into root format)
2125 raw files, to get faster (around 10%)
2126
2127
2128
2129 *** Version 0.4 (2001/09/20)
2130
2131 - This release is made to compile on a root version >= 3.00
2132
2133 - Fixed a bug which causes MReadTree to read the first file only
2134
2135 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2136
2137 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2138
2139 - Added a task to write several container to a root file (MWriteRootFile)
2140
2141 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2142
2143 - Added calculation of the collection area (MMcCollectionAreaCalc)
2144
2145 - fixed some bugs in the Hillas calculation
2146
2147 - added filters to be able to control the task execution dependent on
2148 a parameter (for example: the number of level 1 triggers in a MC-file)
2149
2150
2151
2152 *** Version 0.3 (2001/04/23)
2153
2154 - Many demo macros added
2155
2156 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2157
2158 - Hillas Calculation added
2159
2160 - Standard image cleaning available
2161
2162 - MReadTree is now able to handle more than one file
2163 (Remark: of the same structure)
2164
2165 - Now we are able to display events in a first version of the
2166 Camera event display. To do this we must run the macro
2167 "macros/readCT1.C" to read data from CT1.
2168
2169
2170
2171 *** Version 0.2 (2001/01/24)
2172
2173 - First Implementation of a Gui to read the raw data. Start the
2174 gui with the command mars.
2175
2176
2177
2178 *** Version 0.1 (2000/12/20)
2179
2180 - First official release 0.1
2181
2182 - Changes:
2183
2184 + changed calling style of MRawPixelIterator from do...while to
2185 while-loop