source: trunk/MagicSoft/Mars/NEWS@ 8632

Last change on this file since 8632 was 8632, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 100.5 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Now the output files (calib*.root, etc) also contain the
11 resource file (to check it open it in the TBrowser and choose Print()
12 from the context menu)
13
14 - merpp: Merpp can read file format version 9 now. Please realize
15 that for file format version 9 the extraction range is different
16 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
17 the first and last 15 slices have been removed from all MUX data.
18
19 - mars: Similar to writing movies you can now select events which
20 should be displayed in your display. Therefore add the following
21 lines to your mars.rc:
22 MFEvtNumber.FileName: ganymed00223552.root
23 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
24 The input file can be a ganymed-file after (ganymed*.root) or
25 before (ganymed*-summary.root) file. For example to select all events
26 from your on sample after cuts (excluding the ThetaSq cut) use
27 MFEvtNumber.Selector: DataType.fVal>0.5
28 To show all events from your on-sample after quality cuts
29 use the summary file instead.
30
31 - mars: new ways to call mars are implemented. Instead
32 of calling
33 mars filename.root
34 you can now also use
35 mars sequence.txt
36 or
37 mars sequence.txt inputpath
38 or replace sequence.txt by the sequence number if the default
39 sequence file should be used.
40
41 - mars: The default size has been increased
42
43 - mars: There are two new heckboxes which allow to switch off
44 the calculated image parameters
45
46 - callisto: was broken for MCs... fixed.
47
48 - callisto: improved calculation of spline coefficients a lot. This
49 leads to a further improvement of the event rate calibrating MUX
50 data of about 15% (175evt/s instead of 150evt/s)
51
52 - callisto: finally the raw data we read is now real 16bit (with
53 10bit precision) for MUX data and not a stripped 8bit number
54 anymore. Due to scaling of the numbers (without precision loss
55 into an [0-256[ range, the final numbers for pedestal, pedestalrms
56 and extacted signal don't change. However, at all places where
57 raw data is directly accessed (eg. saturation and variation
58 limits in the signal- and pedestal-extraction) the numbers
59 refer still to the data's 16bit range.
60
61 - callisto: The maximum arrival time difference used in the bad
62 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
63 for both, old FADC and MUX-FADC, data.
64
65 - callisto: Be aware that callisto is now calibrating the arrival time
66 in nanoseconds rather than time slices. Also all following tasks
67 have been changed to assume ns units now. If you star data
68 calibrated with an older version it might be necessary to adapt
69 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
70 to obtain optimal results. The plot in the PulsePos tab
71 will now be in ns, too. This might also mean that the Muon
72 analysis in star might not work as perfect as expected as long
73 as old files read in.
74
75 - star: For speed reasons events suitable for the muon analysis
76 are now also preselected by fConcCOG<0.1 which seems to be a very
77 good preselector for muons.
78
79 - star: is now calculating a new timing parameter the Slope along
80 the major and minor axis of the shower. Therefore a numerical
81 solution of a line-fit is used. To use MHillasExt.fSlopeLong
82 and MHillasExt.fSlopeTrans don't forget to multiply it with
83 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
84
85 - ganymed: The old hadronness and size cuts have gotten new indices
86 (10, 11). The old indices 8 and 9 now mean an additional condition
87 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
88 If you want to switch off this cut just move the line far away enough,
89 e.g. by setting c[9] to -500. Please update your ganymed.rc files
90 accordingly!
91 The unit of c[9] is deg. It is the dist at which your cut will
92 cross the slope==0. The unit of the slope is ns/deg. So if
93 you readin files calibrated with an older Mars-version you
94 have to adapt the default value for c[9] to the FADCs:
95 - Multiply by two for the MUX FADCs (run number > 200.000)
96 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
97 - Multiply by 42 for the meaning of life (run number = 200.000)
98
99 - ganymed: The old Cut0 is now called CutQ and is calculated before
100 the source position is caluclated. If you need a quality cut
101 including source dependant data (be very carefull with this!)
102 you have to use Cut0 instead.
103
104 - ganymed: now properly supports three off regions in wobble mode.
105 It will be the default from now on in ganymed_wobble.rc. To change
106 the number of off-regions use
107 NumOffSourcePositions: 1
108 in your ganymed.rc. Also by default no off-theta cut will be done
109 anymore so that you will get a background level higher than the
110 signal level in your ThetaSq plot for ThetaSq>0.2.
111 Due to this be carefull changing the scaling mode away from
112 "None". You will underestimate your signal if your scale interval
113 is not properly set.
114 (Rem: ThetaSqN is no longer needed)
115
116 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
117 with a real pointing model for the starguider is done, calibrated
118 with more than thousand tpoints taken from this date on.
119
120 - ganymed: was broken for Wobble-MCs... fixed.
121
122 - optim, sponde: should now properly support three off-regions.
123 Just produce your ganymed summary files with three off-regions.
124 optim and sponde will automatically get all off events from
125 all off-regions from this file. Please do not forget to
126 set the scaling in optimwobble.C properly:
127 fit.SetScaleMode(MAlphaFitter::kNone);
128 fit.SetScaleUser(1./3);
129 it is not yet read in automatically (will follow soon).
130 In the case of fixed Scale you can also use
131 cuts.SetThetaCut(MFMagicCuts::kOn);
132 no off-cut needed.
133 Be carefull in case of three off-regions when switching on
134 scale mode. Make sure that the scale interval is set correctly.
135
136
137
138 *** Version 1.2 (2007/05/14)
139
140 - database: The database now has two new values Unsuitable50 and
141 Unsuitable01. They express the number of pixels which are
142 unsuitable for more than 50%, respectively more than 1%, of
143 all calibrated event. It is a more accurate number than the
144 previously used numbers, because they only take the first
145 calibration (ignoring the interleaved calibrations) into account.
146
147 - database: The database now has two other new values UnsuitableMax and
148 DeadMax. They express the maximum number of pixels which were
149 unsuitable, respectively dead, during the sequence. Because
150 of high pedestal rms (cars passing) a few events with very high
151 numbers of unsuitable pixels can happen. Not to suffer from this
152 effect we don't take the highest 0.1% of the numbers into account.
153
154 - general: fixed a bug which caused callisto and star to stop working
155 properly because the callisto output was currupted
156
157 - general: a script called scripts/makemovie has been added which
158 simplified the process of producing several movies from a single
159 sequence with different setup.
160
161 - callisto: Some more code cleanup. Started to remove old obsolete
162 code from cvs.
163
164 - callisto: The extraction of the pedestal with the extractor was
165 not random. It seems that extracting at one position is still biased
166 (for example in the first or last slices we could still suffer from
167 switching noise) Now it is completely random.
168
169 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
170 pedestal files) individual pixels could be skipped due to high
171 variations. This was already the case for the pedestal extraction
172 from the lo-gains since the beginning and properly handled
173 there, but was introduced in the extraction from the pedestal files
174 a while ago. To calculate the average value it was still divided
175 by the number of events procesed not by the number of summands
176 really summed. This let to a pedestal which was a tiny amount too
177 small (for a few piels in the order of 0.1%). This led to an slightly
178 positive offset of the randomly extracted pedestal for a few pixels.
179 I doubt that this has a big effect on the result, because the effect
180 on the individual numbers is quite small. Due to this it is suggested
181 that you rerun your calibration to make sure you are without any
182 avoidable bias.
183
184 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
185 the median rms of the absolute arrival time and expressed in significance
186 levels. This replaces the old meaning of an abolute upper limit. An
187 absolute upper limit doesn't make much sense, because in our data
188 all arrival times are shifted at the same time (in fact it might be
189 a shift of the artificial trigger w.r.t. to the light flash).
190
191 - callisto: Added a new tab "BadPixTm" which shows the time evolution
192 of the number of unsuitable pixels over the whole sequence. This
193 is usefull mainly to judge if an intermediate calibration had
194 problems.
195
196 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
197 of the number of dead pixels over the whole sequence. Dead pixels
198 in this context are unmapped pixels, i.e. pixels which could not
199 be interpolated, and thus are ignored in the further analysis.
200
201 - callisto: It is now possible to use the position of the maximum
202 of the spline as arrival time instead of the leading edge even
203 when using the integral for the signal. Therefor set the extraction
204 type to kIntegralRel ("IntegralRelative") and the relative height
205 ("HeightTm") to -1:
206 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
207 MJPedestalC1.ExtractSignal.HeightTm: -1
208
209
210
211
212 *** Version 1.1 (2007/04/27)
213
214 - general: The new class MGeomCamDwarf contains the camera geometry
215 for our prefered Dwarf camera and can be used to create general
216 geometries of roundish or hexagonal cameras.
217
218 - mars: The default cleaning is now abolute 8.5/4.0.
219
220 - mars: The resource file mars.rc now contains examples for MUX data
221
222 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
223 data containing only 10-bit information is still cooked down to
224 8-bit, by cutting away the lowest 8-bit.
225
226 - merpp: When reading raw data the data is now stored in a single
227 array. The lo-gain array is obsolete. The interface stays the same.
228
229 - callisto: To process the new MUX data use the resource file
230 callisto_mux.rc
231
232 - callisto: The -root and -raw options to read merpped raw data have
233 been removed
234
235 - callisto: If the -mc option is given the sequence-name can now be
236 replaced by the MC sequence number
237
238 - callisto: If the sequence file contains "MonteCarlo: Yes" the
239 -mc option can now be omitted
240
241 - callisto: Started further simplification by removing obsolete
242 dependancies on MCalibIntensity*Cams.
243
244 - callisto: removed unsused intensity calibration from MJCalibration
245 for further simplification
246
247 - callisto: for simplification removed references to
248 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
249 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
250 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
251 (this should at minimum change nothing at all, and at maximum
252 improve thing if these containers where somewhere not handled
253 properly)
254
255 - callisto: Added the option to write an event movie. Please use
256 this option with care (huge files) but exessively to understand
257 our events. For further documentation please refer to the
258 IACT wiki
259 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
260
261 - callisto: Improved binning for the pulse position check histogram
262
263 - callisto: The code calculating the pulse position checknow takes
264 the pedestal into account
265
266 - callisto: The arrival time is now stored with full precision this
267 helps to get rid of artefacts in histograms. For the signal this
268 is not necessray because it is displayed in log-scale anyhow
269
270 - callisto: Fixed a problem with internal exclusions. Pixels which
271 have once been marked as unsuitable didn't get the necessary
272 histograms filled anymore to be rechecked with each interleaved
273 calibration.
274
275 - callisto: The relative arrival time resolution (the rms of the
276 relative arrival time offset) is now checked against its
277 median and the median deviation, instead of the average
278 plus an absolute offset.
279
280 - callisto: The relative arrival time offset is now calculated
281 w.r.t. its median not w.r.t. to an artificial reference pixel.
282
283 - callisto: The relative time calibration now marks pixels with
284 outlaying offset as unsuitable
285
286 - callisto: The interleaved relative time calibration has been switched
287 on. The advantage is that pixels which are marked as outliers
288 now can recover. An improvement over time is not expected, because
289 the relative time calibration seems stable.
290
291 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
292 option can now be omitted.
293
294 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
295 or the option "-mc" is specified as default the monte carlo datacenter
296 paths (/magic/montecarlo/...) are used if not overwritten in the
297 dataset file.
298
299 - ganymed: The output files now contain run- and event-number for all
300 events, accessible as RunNumber.fVal and EvtNumber.fVal
301
302 - ganymed: Added a plot showing the source position in the camera also
303 for wobble mode
304
305 - ganymed: In addition to the existing task which can be setup to
306 be executed after Cut1 a final task called "EstimateEnergy"
307 has been added, executed before writing the final output
308 (ganymed00000000.root). The task setup in all three cases
309 can be choosen individually. (For all three(!) cases you
310 can for example choose MRanForestCalc. For examples see all
311 sponde*.rc and all ganymed*rc)
312
313 - ganymed: If a container "MEstimatedEnergy" is found in the
314 parameter list (eg. because it was setup by MEstimateEnergy)
315 it will be written to the output file.
316
317
318
319 *** Version 1.0 (2007/02/16)
320
321 - database: Website to plot values from the database has been added.
322
323 - database: The rate of spark events as found by star is now kept
324 and the rate after cleaning is now with spark events subtracted
325
326 - general: The changes to the interpretation of phrases lead to
327 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
328
329 - general: Added example files how you can create your own calendar
330 (eg. as christmas present) with Mars. Just run
331 root macros/tutorials/calendar.C
332
333 - general: Added a possibility to display grouped data in the plotdb.C
334 macro (and similar macros). This allows to plot hourly, nightly,
335 weekly, monthly and yearly averages.
336 For more details see the plotall function of the macro
337
338 - general: fixed the error display of the camera display. It showed
339 wrong results.
340
341 - general: fixed a memory leak when reading many MStatusDisplays
342
343 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
344 between a spherical and a parabolic mirror
345
346 - callisto: We have a new pulse position check which takes the properties
347 of the extractor automatically into account. So no need to set
348 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
349 left is done. If possible the lo-gain extraction start and hi-gain
350 extraction end is changed accordingly. If no proper extraction range
351 can be set (hi-gain too much to the left) an error is raised.
352
353 - callisto: New swapped pixels have been found and corrected
354
355 - callisto: Redone the signal extraction this includes:
356 + Unified the algorithms to extract the pedestal for all pedestal
357 extractions done
358 + Unification of hi- and lo-gain into one array
359 + Unification of hi- and lo-gain extraction for Spline and
360 Digital Filter (means now exactly the same algorithm is used,
361 not a copy-and-pasted one)
362 + Store pedestal subtracted data in a common place
363 + Improved extraction algorithms. If the algorithms search a
364 maximum but don't find one they don't return the maximum anymore
365 + Improved the extraction such that a information for signal
366 and time which is consistent is returned
367 + replaced the numerical spline with a (not slower) analytical
368 solution
369 + Lowered the saturation limit from 250 to 245 to make sure that
370 we are far away in all pixels from problems with the clock-noise
371 + The start of the lo-gain extraction is calculated from the hi-gain
372 arrival time. In case of saturation an estimation is used.
373 + the hi-gain window was extended to slice 16. This allows extraction
374 of very late pulses in single pixels or of huge hadron showers.
375 + Now uses the lo-gain extraction range for pedestal extraction,
376 not the hi-gain range in the lo-gain
377
378 - callisto: New hi-/lo-gain calibration constants have been produced
379 for all periods from the statistic of the whole period. They are
380 now used automatically depending on the periods. The old constants
381 where deviation in avarega about 2%-3%. The constants are very
382 stable from period to period (<<1%) except for exchanged channels.
383 In a few cases the constants used so far were off by 1%-2% (maybe
384 temperature effects?)
385
386 - callisto: To gain obsolete space we do not write the
387 MPedestalFundamental anymore. Also calibration and bad pixel
388 treatment is not done for it anymore because it has never been used.
389
390 - callisto: Fixed a bug in the seuqence handling which caused the
391 light condition to be ignored
392
393 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
394 basically the same as "Cleaned" but the distribution devided into
395 the events fullfilling a spark cut or being rejected by it.
396 This cut can be changed from star.rc (see example inside) by
397 the "SparkCut" directive
398
399 - star: Star displays now the average individual pixel-rate (IPR) versus
400 time and the average discriminator threshold (DT) of all pixels.
401
402 - optim: fixed a problem with the optim-macros which was due to a bug
403 in the new phrase parsing
404
405 - ganymed: To get a nice FalseSource plot (instead of the all-information
406 debug plot displayed as a standard plot) use the context menu
407 somewhere between the two upper plots, click on "DrawNicePlot"
408 and enjoy the result. (It is the same context menu which contains
409 the other options)
410 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
411
412 - ganymed/optim/train: The cut program, trainings- and optimization
413 macros could run with less files found than expected from the
414 sequence-files. No the execution is stopped in this case.
415
416 - ganymed: now stores the dataset in the output file with all information
417 contained (as sequence number, sequence path, data path) so that the
418 used dataset file can be recreated complete from the output
419
420 - sponde: now also allows the uasge of random forest
421
422 - sponde: added a plot showing the cut efficiency
423
424 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
425 errors (eg. effecting the collection area) because the errors of the
426 two histograms were swapped in the calculation, which makes a difference
427 in the case the histograms contains weighted events. Aditionally the
428 totalarea was incorrectly taken into account, which results in too small
429 errors, which makes a difference at low statistics were the errors
430 or the collection area dominate.
431
432
433
434 *** Version 0.10.3 (2006/10/23)
435
436 - database: Implemented ObservationMode flag in websites.
437
438 - database: For sequences there is now also the stoptime available on the
439 websites.
440
441 - database: Removed ManuallyChanged flag from sequence-info websites,
442 as it is not needed anymore with the new sequence building algorithm.
443
444 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
445 Class for calculation of confidence intervals (upper limits).
446 Use model 3 or 4 for upper limit calculation for MAGIC observations.
447 Please read the class instruction of TRolke for more information.
448
449 - general: The programs now return 0xfe if the requested resource file
450 doesn't exist.
451
452 - general: Errors comming from root itself are now not output to
453 stderr anymore but to our default (colored) log-stream.
454
455 - general: Changed the interface to TFormula such that now everything
456 is parsed by TFormula, which should allow to use phrases even
457 without paranthesis correctly parsed.
458
459 - callisto: replaced the AdHoc number of effective integration slices
460 in the digital filter by an average of the correct number, averaged
461 over all possible set of weights. This also gives correct numbers
462 for the lo-gains which were totally wrong before.
463
464 - callisto: drastically reduced memory consumption by not storing
465 all intermediate calibration results in memory anymore (we might
466 write them into a file in the future)
467
468 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
469 debug plot displayed as a standard plot) use the context menu
470 somewhere between the two upper plots, click on "DrawNicePlot"
471 and enjoy the result. (It is the same context menu which contains
472 the "DrawAll" option)
473 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
474
475
476
477 *** Version 0.10.2 (2006/10/15)
478
479 - general: changed the building of the sequence files such, that
480 the source-/project name in case of wobble-sources is not the
481 source/project of the first data run anymore but the new generalized
482 wobble source/project
483
484 - general: Added some functions to MAstro to calculate sun and
485 moon properties
486
487 - general: Added two new macros (starvisday.C and starvisyear.C)
488 which allow to plot the visibility of several stars in one day
489 or of one star along one year
490
491
492
493 *** Version 0.10.1 (2006/10/11)
494
495 - general: HTML logging output was distorted... fixed.
496
497 - general: Changed the writing of the sequencefiles such that only
498 as many pedestal files as giving at least 1000 pedestal events which
499 are nearby the first calibration run are used as pedestal runs
500
501 - sponde: In the calculation of the collection area(s) and the
502 distribution for MOnte Carlo and estimated energy the error
503 calculation was wrong because root didn't take the errors
504 properly into account... fixed.
505
506
507
508 *** Version 0.10 (2006/10/10)
509
510 - general: all executables now check consistency of the root version
511 installed with the root version used for compilation. The return
512 code in this case is 255.
513
514 - general: The algorithm to build seqeunces has been redesigned
515 completly. It is now more flexible in terms of a resource file
516 resources/sequences.rc which can be used to partly overwrite
517 the default algorithm and defined the important part of the
518 algorithm. It also takes correctly into account several ways
519 of taking wobble-data. Currently the new algorithm doesn't take
520 the number of pedestal events anymore into account (so a sequence
521 could have much less than 1000 pedestal events and data runs are
522 no-more used instead)
523
524 - general: a lot of small changes to make the code compatible with
525 root 5.12/00 and gcc 4.1
526
527 - general: Fixed some warnings thrown if more warnings are switched
528 on in the compiler
529
530 - general: Added a function to MMath which returns the Median of
531 the distribution abs(y[i]-median) but at 68:32 division instead
532 of 50:50, which is somehow the median counterpart of the rms.
533
534 - general: MAstroCatalog allows now to read calatog files (as bsc5)
535 even if they are compressed with gzip (recommended compression
536 is with "-1")
537
538 - showplot:
539 + batch mode creation of image files now works with root 5.12/00
540 + added support for writing bmp (though it never produces
541 bmp which can be read by programs like xv or gimp)
542 + added support for xml
543 + added new option to start the display with a different size, by
544 --display-width=nnn or --display-height=nnn
545 + added options to define the canvas size when the display is started
546 --canvas-width=nnn or --canvas-height=nnn
547 the option can also be used for batch-mode conversion
548 + added an option which automatically fits the display size to the
549 desktop-size: --auto-size
550
551 - merpp: didn't recognize files with the extension .raw.gz - fixed.
552
553 - merpp: allow the reports to have 1000ms due to a bug in the camera
554 program.
555
556 - callisto: New swapped pixels have been found and corrected. For
557 details see MRawRunHeader::FixAssignment()
558
559 - callisto: Callisto now raises an error if one of the input files could
560 not be opened.
561
562 - callisto: In some rare cases it could happen that in the signal
563 extraction of the digital filter the extractor returned nonsense
564 results due a wrong initializion of a variable (this happens in
565 cases in which the extracted signal is exactly zero or the
566 digital filter couldn't slide because of a too small extraction
567 window, which could happen in the lo-gain extraction)
568
569 - callisto: The lo-gains have been marked as valid in some cases
570 when they got not extracted at all (deltsumlo=deltatimelo=0) because
571 the allowed extraction range (fLoGainLast-fLoGainFirst) was
572 smaller than the number of slices (fLoGainWindowSize) needed
573 by the lo-gain extractor
574
575 - callisto: Updated absolute calibration constants (muon calibration)
576
577 - callisto: fixed a bug which caused the hi-gain saturation not
578 to be handled properly in the spline (the position of the
579 saturation was calculated incorrectly)
580
581 - callisto: fixed a bug which gave weird results if hi- _and_
582 lo-gain could not be extracted properly. In some cases hi-
583 and lo-gain have not been extracted at all and the random result
584 got calibrated. In other cases the hi-gain was saturating and the
585 lo-gain has not been extracted. For this a completly arbitraty
586 scale factor was applied to the result from extracting the
587 charge of the saturating hi-gain.
588
589 - callisto: improves handling of extracted signal if lo- and/or
590 hi-gain could not be extracted properly. If no appropriate
591 calibration of either the signal or the arrival time is possible
592 the pixel is now markes as unsuitable instead of estimated.
593
594 - callisto: Fixed a problem in the spline extraction which gave
595 weird results if the signal was extracted from the first (and
596 highest) slice (as a workaround extraction from the first
597 slice has been forbidden)
598
599 - callisto: Fixed a bug regarding the use of the QE which doesn't
600 effect the result because the default is used anyhow.
601 (The bug was there since 14/07/2005)
602
603 - callisto: Changed the default for fgLoGainStartShift to -2.4
604
605 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
606 factors to be always 10 for all pixels as soon as the first
607 calibration update has happend.
608
609 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
610 was off by more than one slice (which gives wrong values for
611 pixels which have saturated the hi-gain) This was a problem
612 mainly for timing studies, not so much for the automatic standard
613 analysis. Also the values for the Spline have been changed slightly:
614 + Digital Filter from 1.70 to 0.95
615 + Spline from 1.39 to 1.30
616 The numbers were sorted out by an extensive test in the
617 test-database.
618
619 - callisto: Removed the tab showing the average calibrated arrival
620 time. It never gave useful information.
621
622 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
623 lo-gain pulse for data pulses if hi- and lo-gain have saturated
624 and both were extracted because the hi-gain was above the
625 LoGainSwitch.
626
627 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
628 lo-gain pulse position (after application of LoGainOffset, which
629 means in the ideal case it is 0) for data pulses if hi- and lo-gain
630 have saturated and both were extracted because the hi-gain was above
631 the LoGainSwitch.
632
633 - callisto: After extensive tests a new threshold level for determination
634 of the pulse position has been found at 50phe. This is due to the
635 fact that for lower pulses the arrival time changes its average
636 behaviour dramatically. It tends to the average of the extraction
637 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
638
639 - callisto: Added two more plots to the calibration part. The average
640 extracted signal and the average extracted arrival time as
641 extracted by the signal extractor (This can help debugging problems
642 because it doesn't involve a fit)
643
644 - star: changed the fit for the effective on time such that initial
645 values are calculated automatically now instead of using build
646 in values. This makes the fit more indepedant of the underlaying
647 rates. With a test of ~350 sequences in the test database it could
648 be shown that the new fit gives the same result +/-1sek.
649 The highest deviation was +5s the lowest -10s. You can now control
650 the bahaviour with two resource values:
651 MHEffectiveOnTime.FistBin: 3
652 MHEffectiveOnTime.NumEvents: 12000
653 Use FirstBin=1 and NumEvents=120 to fit the effective on time
654 from the resulting gamma candidates
655
656 - star: The Center histogram in MHHillas is now by default displayed
657 with the colz draw-option
658
659 - ganymed: now produces valid error codes if failed
660
661 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
662 with the option "hadronness" instead of "area" or "both" if
663 you want to use both cuts. The hadronness cut includes a fixed
664 cut in hadronness (index 8) and a fixed cut in size (index 9).
665
666 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
667 the M3Long of the anti source to be not properly evaluated
668 (actually is was evaluated as a unique random number) in case
669 of optimization with anti-theta cut switched on. This might have
670 lead to improper, but not necessarily wrong, optimization results.
671
672 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
673 how to use random forest
674
675 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
676 ganymed_onoff.rc. Seems to be unintentional that they were different.
677
678 - sponde: Since the introduction of the possibility to define a
679 normalization energy instead of using the integral the default
680 was not using the integral anymore but a normalization energy of
681 1GeV. It is now the integral again.
682
683 - sponde: Fixed a problem in the weighting which did not allow
684 a MC slope of -1.
685
686
687
688 *** Version 0.9.6 (2006/05/24)
689
690 - general: changed the binning of the azimuthal profile of the camera
691 such that it is aligned with the 60deg boundaries.
692
693 - merpp: better handling of problems with the TH, TD part of the
694 CC-REPORT for files older than 200507190 and 200412210
695 respectively
696
697 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
698
699 - merpp: implementd latest changes in starguider reports (sinc 9th May)
700
701 - callisto: if an arrival time is extracted outside the fadc range is
702 was set to the boundary before. Now a random number is assigned
703 instead to avoid unfortunate coincidences of arrival times just
704 by this arbitrary value.
705
706 - callisto: added a new option to callisto.rc which allows
707 to set the maximum arrival time difference allowed for the
708 badpixel algorithm to determin whether a pixels belongs to a shower:
709 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
710
711 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
712 to 0.9 as suggested by Stefan due to a recent study on the fraction
713 of pixels surviving the image cleaning
714
715 - callisto: switched off error in case of "pulse is too much to the left"
716
717 - callisto: The extraction window is not adapted anymore. This means that
718 the pulse is extracted from the full range. The draw-back is that the
719 background (pedestal) will become slightly higher. Switching on/off
720 the PulsePosCheck in the callisto.rc only effects filling the
721 histograms.
722 WARNING: If the pulse is too much to the left data is calibrated!
723 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
724 in the database to make sure that your data is valid!
725
726 - star: Show also the number of stars correlated correctly by the
727 starguider
728
729 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
730 than one off-source region in wobble-mode. To use it add the following to
731 your ganymed_wobble.rc:
732 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
733 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
734 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
735 + Cut1.ThetaCut: None
736 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
737
738 - ganymed: in the case the latest report is older than a default (currently
739 one minute) and the current report will be skip the starguider
740 correction and calibration will be reset. The maximum age can be
741 setup from ganymed.rc by (minutes):
742 MPointingDevCalc.MaxAge: 1.5
743
744 - ganymed: A first implementation showing all size-bins for the theta-sq
745 resp. alpha-plots in a single tab automatically
746
747
748
749 *** Version 0.9.5.1 (2006/05/05)
750
751 - general: Added a new option "zdiff" to the Makefile which runs
752 "cvs diff" as "make diff" would do, but with compression
753
754 - general: accelerated MTFillMatrix (used for eample in all training
755 and optimization macros) by skipping some obsolete calles in the
756 eventloop the first and second loop could be accelerated by ~20%
757
758 - general: Added a missing feature in the MFilterList class which
759 prevented MFEnergySlope from working correctly in trainenergy.C
760
761 - general: Accelerated the random forest training and usage a bit
762
763 - merpp: Adapted to new raw data file format version 6
764
765 - merpp: fixed a problem with reading the starguider reports
766 after 6.3.2006
767
768 - callisto: At some times six pixels had to be exchanged manually in the
769 data. If the pixels to be swaped are both not found, an error was raised
770 and calibration was stopped. Now it is assumed they are intentially not
771 mapped and the Error has been changed to a Warning.
772
773 - star: Added new image cleaning based on the arrival time of the shower.
774 The new cleaning can be accessed using the parameter "Time" instead of
775 the the old one (like "Absolute) in the star.rc-file.
776 Recommended parameters:
777 + MImgCleanStd.CleanLevel1: 8.2
778 + MImgCleanStd.CleanLevel2: 5
779 + MImgCleanStd.CleanRings: 2
780 + MImgCleanStd.KeepSinglePixels: No
781
782 - star: Simplified the calculation of the effective on time. By letting
783 the fit start in the third bin the result should become more stable.
784 The fit quality is now ignored for the theta-plot which is not used
785 in the analysis later. Still better pre-cut which, for example,
786 remove events triggered by car-light (rate changing on a short
787 time-scale) are missing.
788
789 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
790 for optimization (kWeakSource) which is suggested by the Berlin
791 people for weak sources.
792
793 - macros: plotdb.C:
794 + if no dataset and no time-interval is given only sequences with
795 an effective on-time above five minutes are plotted anymore
796 + added a new tab "RelTime" displaying the relative on-time
797 (effective on-time divided by the observation time)
798
799 - macros: optim*.C: by skipping some obsolete calles in the eventloop
800 the optimization became a lot faster
801
802 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
803 To display them just delete the pads displayed on top.
804
805 - ganymed: fixed a bug which could cause strange behaviour in wobble
806 mode if no starguider information was available due to an incorrect
807 initialization of the starguider calibration
808
809 - ganymed: The scale region in the False Source Plot (MHDisp) can now
810 be changed from within the plot. It can also be setup from the
811 resource file using:
812 + MHDisp.fScaleMin: 0.325
813 + MHDisp.fScaleMax: 0.475
814
815 - ganymed, showplot: Fixed a problem with the fit to the off-data
816 (HistOff) which could cause a time lag or an inifinite loop.
817 The bug did not effect the results at all.
818
819 - sponde: Added a new tab showing the effective collection area after
820 trigger (including the software trigger)
821
822 - sponde: MMcSpectrumWeight has a new option which allows to define
823 the scaling factor not by the integral of the events but at
824 a defined energy:
825 e.g. MMcSpectrumWeight.NormEnergy: 200
826
827 - MTFillMatrix, sponde: by skipping some obsolete calles in the
828 eventloops the loop could be accelerated by ~20%
829
830
831
832 *** Version 0.9.5 (2006/03/13)
833
834 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
835 and added the standard Disp-parametrization
836
837 - macros: added a new macro datacenter/macros/plotstat.C allowing
838 to plot statistics about the data processing
839
840 - macros: added a new macro to plot the muon correction coefficients
841 versus period (macros/plot/mucal.C)
842
843 - showplot: path inflation for ganymed files was broken
844
845 - callisto: Fixed an important bug. When the number of saturating pixels
846 were calculated the bad pixel information already available from the
847 calibration was ignored. This yields wrong values in case pixels
848 are broken and saturate all the time or randomly.
849
850 - callisto: Updated Muon calibration constants. Spline data now also uses
851 different values for different periods
852
853 - star: The time-evolution shown in the effective on-time plot now displays
854 the axis range (if there are no holes it should be similar to the
855 effective on-time)
856
857 - star: Added two new image parameters:
858 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
859 the three pixels next to the center of gravity and the size
860 + MNewImagePar.fConcCore: The ratio of the signals of all
861 pixels inside or touching the ellipse and the size
862
863 - ganymed: now stops in requested source isn't found in catalog file
864
865 - ganymed: Many improvements to the phi-plot in wobble mode:
866 + with a template the ideal background is displayed
867 + a possible camera inhomogeneity is taken into account
868 + the anti theta cut is better supported
869 + the phi cut is automatically calculated from the theta cut
870 See the examples in ganymed_wobble.rc for more details.
871
872 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
873 times the bin-width instead of the absolute energy
874
875 - ganymed: New cuts for on/off and wobble mode
876
877 - ganymed: The smearing of the False Source plot has been increased
878 to 0.06
879
880 - ganymed: The starguider calibration can now be changed from the
881 resource file.
882 See the examples in ganymed*.rc for more details.
883
884 - ganymed: added a new option for on-/off-observations
885 MJCut.RandomSourcePosition
886 If switched on the distribution of observation time of the source
887 position in the camera is calculated from the on-data and randomly
888 applied with this distrbution to the off-data.
889
890 - ganymed: by skipping some obsolete calles in the eventloop the
891 first and second loop could be accelerated by ~20%
892
893 - ganymed: The default in ganymed_onoff.rc is now to determin the source
894 position in the off-data randomly according to its distribution in the
895 on-data.
896
897
898
899 *** Version 0.9.4.3 (2006/02/13)
900
901 - general: Fixed a bug in most of the programs which prevented the
902 compile date in the startup message to be displayed
903
904 - general: Simplified program calls. The following abbreviations
905 are now possible:
906 showlog callisto 55599
907 showplot signal 55599
908 star 55599
909 callisto 55999
910 ganymed 2
911 In this cases the corrsponding root-, log-, sequence- or dataset-
912 filename is automatically compiled using the default datacenter
913 paths ("/magic/*")
914
915 - general: Fixed a long outstanding bug which made axis tick marks
916 disappear if MDataFormula was used (eg. abs(x))
917
918 - general: Updated MMath with new functions to calculate the results of
919 a exponential, logarithmic and powerlaw fits analytically.
920
921 - general: Updated some macros with comments:
922 + macros/optim/optimdisp.C
923 + macros/optim/optimenergy.C
924 + macros/optim/optimwobble.C:
925
926 - general: MTFillMatrix (the class to fill one or two MHMatrix from
927 files) now allows adding a pre-cut like in the optimization. E.g. this
928 is useful to perform g/h-separation cuts before training the random
929 forest.
930
931 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
932 correctly assigned in the raw data assignement table. A fix to correct
933 the assignment tabel have been implemented.
934
935 - general: MAstroCatalog now allows rotating of the sky-grid and stars
936 by 90, 180 and 270 deg.
937
938 - general: the macro plotdb.C now allows to highlight sequences belonging
939 to a datset. For more details see the descritions in the macro.
940
941 - StatusDisplay: Fixed the algorithm to calculate the size ratio
942 of the display, it gave wrong results espacially for big sizes.
943 Now the embedded canvas should always have a ratio width/height=3/2.
944 The "Size" options have been updated with values fitting the 3/2
945 size ratio.
946
947 - RanForest:
948 + Updated the random forest classes to support also the
949 regression method implemented by Thomas H.
950 + added new tutorial macro how to train the random forest
951 for energy estimation (macros/optim/rfenergyest.C)
952 + new classes to train the random forest (still in development)
953 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
954 + new tutorial macros for random forest training in macros/train
955 trainenergy.C, traindisp.C, trainseparation.C
956
957 - mars: now allows to setup a cut in the resource file mars.rc to choose
958 the events to be displayed, eg:
959 Cut.Condition: {0} && {1}
960 Cut.0: MHillas.fSize>100
961 Cut.1: MHillas.fSize<900
962
963 - merpp: Made aware of the new .rep format 200510250. This includes
964 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
965 the discriminator thresholds (MCameraTD) and the disciminator
966 delays (MCameraTD). All of them come with the CC report and are therefor
967 written to the CC tree.
968
969 - callisto: fixed a bug in the calculation of the arrival times in
970 the Digital Filter. They were all shifted by the same amount
971 fHiGainFirst. This caused an offset in the order of the position of
972 the left border of the extraction window in the times calculated
973 from high-gain and from low-gain. The bug effected only the absolute
974 arrival times. The bug was there since 30.1.2005.
975
976 - callisto: Changed the ExtractionWindow for the pulse position check
977 such that the camera inhomogeneity becomes as less as possible and
978 comparable to the pulso position check switched off. More details
979 on the study will be given at our result web-page.
980
981 - ganymed: ganymed.rc, ganymed_onoff.rc:
982 changed to new cuts trained with 1ES1218 and Crab-data
983 for maximum sigma*log10(excess)
984
985 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
986 a new option was implemented to estimate Disp (CalcDisp)
987
988 - ganymed: Implemented two new options which allow
989 to overwrite the default path to search for the sequence files
990 --ins=/magic/sequences
991 and where to search for the image data
992 --ind=/magic/data/star
993
994 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
995 dx/dy from the resource file by
996 MSrcPosCorrect.Dx
997 MSrcPosCorrect.Dy
998
999 - ganymed: fixed reading the source catalog. Only as many chars
1000 as the requested source name had were compared (If a source
1001 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1002 were requested it could happen that the coordinates of
1003 "1ES1218" were read) The source coordinates are now printed
1004 in addition to its name to the logging output.
1005
1006 - ganymed: changed the background fit in the case of a ThetaSq function
1007 from a polynomial to a exponential, this should give a big improvement
1008 for on-only analysis'
1009
1010 - ganymed/sponde: Calculation of the error of single size-/energy-
1011 bins now uses Li/Ma (5) instead of LiMa (17)
1012
1013 - sponde: Added a plot E^2*dN/dE
1014
1015 - sponde: The energy estimator plot should now show values like
1016 they are commonly used.
1017
1018 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1019 (a powerlaw with cutoff didn't work before)
1020
1021
1022
1023 *** Version 0.9.4.2 (2005/10/01)
1024
1025 - general: added new tutorial macro macros/tutorials/threshold.C:
1026 how to calculate the threshold
1027
1028 - general: added a new game. Start it from the interpreter with
1029 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1030 and MagicReversi)
1031
1032 - general: neighbor pixels in MGeoms are now sorted clockwise
1033
1034 - merpp: made aware of new format 20050829-0
1035
1036 - callisto: New scale factors from muon analysis, stored in new
1037 resource file resources/calibration.rc
1038
1039 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1040 the eventloop if something went wrong. This is necessary for the
1041 automatic processing
1042
1043 - callisto: Implemented a new treatment for the time information
1044 developed by S.Ruegamer, this should give much better response than
1045 the old very primitive algorithm. This is especially important
1046 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1047 treatment was buggy! As neighbor pixels to interpolate the
1048 arrival times always the pixels 0 to 5 were taken)
1049
1050 - callisto: In addition to the new treatment of arrival times the
1051 decision of the treatment whether a pixel contains shower
1052 information or not is used to improve the signal interpolation
1053 further. Previously interpolated pixels showed a non-zero signal
1054 do the peak searching signal extractors. Having a signal pixel
1055 beside raised the signal above the cleaning level. Thus the
1056 pixel survived cleaning to often but with a too low mean signal.
1057 By replacing empty pixels with a gaus (mean and rms from the
1058 corresponding Area entries in MPedPhotCam) this effect can
1059 be supressed.
1060
1061 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1062 got lost when the events were stored by the calibration... fixed.
1063 (This was no problem for normal image cleaning because the pixel
1064 content was artificially set to 0 not surviving standard cleaning
1065 algorithm)
1066
1067 - callisto: Fixed a bug which caused the random and peak-search pedestal
1068 extracted with an extractor to be exchanged for the first (roughly)
1069 500 events (*Extractor and *ExtractorRndm).
1070 (They were simply exchanged in callisto.cc) This bug might have been
1071 introduced in Mars 0.9.4 when the order of calculation of the two
1072 types of pedestal in callisto got exchanged. The bug only effects
1073 the first seconds of data of each sequence.
1074
1075 - star: Taking the arrival time of Muons into account the calculation
1076 of the parameters could be made independant of the noise
1077 (pedestal rms). The dependance was due to the bias of the peak search
1078 extractor. Now only a ZA dependamcy is left which is not yet fully
1079 understood.
1080
1081 - ganymed: The sequences were still not sorted correctly in any case,
1082 because they were sorted by the full qualified path name. Now they
1083 are sorted by their sequence number.
1084
1085 - ganymed: new values for the spark-event-cut
1086
1087 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1088
1089
1090
1091 *** Version 0.9.4.1 (2005/08/18)
1092
1093 - callisto: fixed some problems with the calibration in case of
1094 inteleaved events. Therefor the final and some intermediate
1095 fits are skipped which would take place on partly filled #
1096 histograms and gave wrong results or failed completely.
1097
1098 - callisto: If the intermediate finalization of the histograms
1099 calculating the mean charge of the calibration signal fails
1100 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1101
1102 - ganymed: Fixed some bugs which caused problems in On-only mode.
1103 Still the false source plot doesn't give reasonable results.
1104
1105
1106
1107 *** Version 0.9.4 (2005/08/05)
1108
1109 - general: Fixed the ZA binning. It did not correctly fit the
1110 MC binning
1111
1112 - general: Added a class to correct for the missfocussing in
1113 April (MSrcPosCorrect)
1114
1115 - general: Random Forest energy estimator should now work properly
1116
1117 - general: MHCamera now displays the profiles in deg instead of mm
1118
1119 - general: MH::SetPalette offers a lot of new palettes
1120
1121 - general: MHillas - the case of CorrXY==0 is now handled properly
1122
1123 - general: implemented the possibility to change the line and
1124 marker style of a sky-grid drawn by MAstroCatalog
1125
1126 - general: Runs in sequences and datasets are now automatically
1127 ordered (it is assumed that the order of their filenames correctly
1128 represents the order of observations) to ensure correct reading
1129 of the subsystem data
1130
1131 - general: Runs cannot be added to a sequence twice anymore. Also
1132 Sequences cannot be added twice anymore to a dataset.
1133
1134 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1135 It gave wrong results by 1./2pi
1136
1137 - showplot: got a new option to start a root interpreter, too
1138
1139 - mars: now displays a rough estimate of Disp and the third moment
1140
1141 - mars: now displays the event time MTime if available
1142
1143 - mars: show muon parameters graphically
1144
1145 - mars: now the file to open can be given as commandline
1146 argument
1147
1148 - merpp: Added support for new arehucas version >= 200507190
1149 implementing values for three temperature sensors in the
1150 counting house (MCameraAUX) and the name of the HV settings file
1151 (MCameraHV).
1152
1153 - merrp: Also fixed some problems with wrong versions numbers stated
1154 by arehucas and implemented some fixed for old versions (<200407070)
1155
1156 - callisto: MCalibrationHiLoCam can now be printed from its context
1157 menu, eg in the TBrowser
1158
1159 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1160 - 1.39 (MExtractTimeAndChargeSpline)
1161 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1162 This is important mainly for timing studies.
1163
1164 - callisto: Changed limits in MHCalibrationChargeCalc from
1165 - -100.125 to -98 (fgChargeHiGainFirst)
1166 - 1899.875 to 1902. (fgChargeHiGainLast)
1167 - -100.25 to -99 (fgChargeLoGainFirst)
1168 - 899.75 to 901. (fgChargeLoGainLast)
1169 Introduced new limits:
1170 - fgNumLoGainBlackoutLimit: 0.05
1171 - fgLoGainBlackoutLimit: 3.5
1172 - fgLoGainPickupLimit: 3.5
1173
1174 - callisto: The handling of automatic weights for the digital filter
1175 has been improved. There are now new calibration weights special
1176 for Monte Carlo calibrations.
1177
1178 - callisto: Updated Muon scale with latest results (1% difference
1179 for most data, 5% for Mar/Apr'05)
1180
1181 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1182 was saturated and the blackout-events in the low-gain exceed the
1183 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1184 This excludes those pixels which have a saturating high-gain
1185 channel, but the low-gain switch does not switch often enough
1186 to make the distribution reliable.
1187
1188 - callisto: fix a bug counting the number of saturated events. Up to now,
1189 the number of saturated slices was counted (which is one for a not too
1190 high number), but for some (pathological) pixels, many more slices
1191 saturated and produced wrong limits.
1192
1193 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1194 + MCalibrationRelTimeCam.CheckFitResults: Yes
1195 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1196 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1197 + MCalibrationRelTimeCam.CheckOscillations: Yes
1198
1199 - callisto: introduce max. number of events for intercalibration,
1200 the rest gets skipped. Default: 4096
1201 The calibration causes too many un-reliable pixels if more
1202 than about 5000 events are treated (@500 Hz) because of the
1203 mode hopping of the VCSels. However, in the past, some
1204 calibration runs have been taken (erroneously) with more
1205 than 5000 events, especially the intensity scans where
1206 a good precision is needed.
1207
1208 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1209 photo-electrons for the spline extractor by 1-2% (correctly).
1210
1211 - callisto: The intercalibration is now done using a full f-factor
1212 method instead of a simple update. This makes things slower but
1213 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1214 changes.
1215
1216 - callisto: MPedestalY3 now uses the same extraction range as the data
1217 as calculated by MPedestalY2
1218
1219 - callisto: A check of the fraction of allowed unsuitable (10%) and
1220 unreliable (30%) pixels has been addded when the conversion is
1221 calculated from interleaved events
1222
1223 - star: fixed a bug which caused MEffectiveOnTime containers not to
1224 be written. In the worst case they were skipped almost all, in the
1225 best case they were all ok. It depends on how often the new value
1226 was assigned just with an event which was skipped later by another
1227 task
1228
1229 - star: new histograms MHPointing and MHRate
1230
1231 - star: New tab (Currents) displaying the time evolution of the mean
1232 DC currents
1233
1234 - star: New tab (MeanRms) displaying the time volution of the mean
1235 Pedestal Rms
1236
1237 - star: Output now contains MReportStarguider
1238
1239 - star: Improved muon analysis. Due to the absense of a constant
1240 for the gaus fit for arc width and the fact that the arcwidth
1241 plot was a histogram instead of a profile the resulting psf
1242 became pedestal rms dependant
1243
1244 - ganymed: added new plot (MHPhi) for wobble mode as described in
1245 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1246
1247 - ganymed: corrects now (correctly?) for the misspointing in
1248 May/April 05
1249
1250 - ganymed: Two new default templates for ganymed.rc are avilable:
1251 ganymed_onoff.rc and ganymed_wobble.rc
1252
1253 - ganymed: The first version of MFMagicCuts has been released
1254
1255 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1256
1257 - ganymed, sponde: There are two new options to determin the number
1258 of bins for the signal region (NumBinsSignal) and the number of
1259 total bins (NumBinsTotal) in the MHThetaSq histogram
1260
1261 - ganymed: optimized palettes for MHDisp
1262
1263 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1264 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1265 sqrt(2) to large
1266
1267 - ganymed: The false source plot (MHDisp) is now based on Disp
1268 and a background model determined in the first loop is
1269 subtracted
1270
1271 - ganymed: MFMagicCuts are now available in the cvs. The correct
1272 solution for the disp ambiguity problem is now calculated using
1273 the third moment. The third moment cut therefor is skipped.
1274
1275 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1276 already determined by the third moment along the major axis and
1277 so its actual sign is aligned along the major axis of the shower.
1278
1279 - ganymed: If starguider data is available it is taken into account
1280 when calculating the source position. This is especially important
1281 for wobble data at high zenith angles and culmination data.
1282
1283 - ganymed: If available the starguider data is taken into account as
1284 good as it is possible without a starguider calibration. To switch
1285 it off add
1286 MPointingDevCalc.MaxAbsDev: -1
1287 to your ganymed.rc
1288
1289 - sponde: the zenith angle distribution is now weighted instead of
1290 choosen by default. This gurantees higher statistics in the highest
1291 and lowest energy bins. To switch this behaviour off use...
1292
1293 - sponde: now automatically displays the energy threshold
1294
1295
1296
1297 *** Version 0.9.3 (2005/06/03)
1298
1299 - general: MMcEvt now derived from MMcEvtBasic which should
1300 have no influence on compatibility with older camera files
1301
1302 - general: Implemented a new option to MReadReports which allows
1303 to force reading of the first event of some trees (eg. Drive-tree)
1304 before any other tree.
1305
1306 - general: Made a fix to MPointingPosCalc which assumes that the
1307 run-type is real-data if Process is called before ReInit, such
1308 that also the very first Drive-events in a run are treated
1309 correctly.
1310
1311 - shoplot now displays the filename in the title bar of the window
1312
1313 - merpp: new options: --auto-time-start --auto-time-stop which
1314 allow to cut updating with slow-control at the start- or
1315 (previousle --auto-time only allowed: and) stop-time of
1316 the run stored in the runheader.
1317
1318 - callisto: changed default of fgFallTimeHiGain in
1319 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1320 already set as default in callisto_Dec04Jan05.rc
1321
1322 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1323 now changes the filename for new weights automatically for
1324 cosmics, MC and for different calibration colors.
1325
1326 - callisto: a problem with the order of some code cause the
1327 name of the weights file in MPedestalY2 to be ignored.
1328 Wrongly the calibration_UV weights were used instead
1329 of the cosmics weights set in callisto.rc.
1330
1331 - callisto: should allow ct1 pulser data when the color is
1332 explicitly set also for pretty new runs
1333
1334 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1335 to introduce an additional scale factor (should be around 1)
1336 to adapt for slight deviations in different extractors from
1337 the MC calibration. For MC calibrations the scale factor
1338 is fixed to 1
1339
1340 - callisto: MFCosmics should handle very high signals a bit
1341 more accurate now
1342
1343 - callisto: when calculating the mean pedestal rms for different
1344 pixel sizes or sectors also kUnsuitableEvt is now taken into
1345 account - not only kUnsuitableRun
1346
1347 - callisto: '-raw' option is now the default
1348
1349 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1350 This has the advantage that mean values in the calibration (eg
1351 arrival times) are calculated more accuratly.
1352
1353 - callisto: In the resource file callisto_Dec04Jan05.rc
1354 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1355
1356 - callisto: new Hi-/Lo-Gain intercalibration constants
1357 hilocalib_sp1.root and hilocalib_sp1_mc.root
1358
1359 - callisto: changed default for MJPedestalY2.MaxEvents
1360 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1361
1362 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1363 has changed from 9.0 to 6.0. This is necessary to exclude two very
1364 ringing pixels in September which - when kept - destroy the image
1365 cleaning around them (Markus G.)
1366
1367 - callisto: (!) The Muon analysis of all data taken so far has
1368 suggested that different extractors give slightly different
1369 absolute results after calibration, due to there different
1370 handling of the calibration- and cosmics pulse shape. Although
1371 the over all calibration seems to be a bit to pesimistic (or
1372 the MC seems to be a little bit - 3-5% - too much attenuated).
1373 There for correction factors have been introduced which correct
1374 the calibration constants by
1375 0.956937799 for Digital Filter (callisto.rc)
1376 and
1377 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1378 calibration. The main advantage is, that both data types can
1379 be easily analysed together and compared to the same MC sample.
1380 The factors are choosen such, that the reference is now a
1381 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1382
1383 - star: fixed a bug which caused the first bin of the histograms
1384 vs time to disapear in PostProcess. This gave wrong results
1385 on the screen. The output and all following programs not
1386 directly accessing the histograms haven't been affected
1387
1388 - star, ganymed: Made sure that always the first Drive-tree event
1389 is read and Processed before the first data event was read.
1390
1391 - ganymed: implemented the possibility to replace the standard
1392 false source plot with a different one. For example: If
1393 you want to use a Disp based FS plot use the resource:
1394 NameHistFS: MHDisp
1395 For details about the requirements of these plots look
1396 at the corresponding classes
1397
1398 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1399 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1400 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1401 case MAlphaFitter is setup correctly. For On-Only optimization
1402 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1403 RunOn() instead of Run(). For energy estimation MJOptimize
1404 has been replaced by MJOptimizeEnergy
1405
1406 - sponde: The input MC spectrum can now be weighted to fake a
1407 different spectrum. This is done via MMcSpectrumWeight. For
1408 more details see the class description and sponde.rc
1409
1410 - sponde: The paremeter comparsion plots are not scaled by
1411 their entries anymore. Instead the MC plot is scaled by using
1412 the result spectrum of the analysis. If the input MC spectrum
1413 and the result spectrum has different slopes the absolut
1414 normalization is normally wrong.
1415
1416
1417
1418 *** Version 0.9.2 (2005/05/20)
1419
1420 - general: Changed the default paths for calibrated data and image
1421 files. (The implemented access to these files doesn't yet exist)
1422
1423 - general: support for MRunIter has been removed from the job classes
1424 (use the setter functions of MSeqeunce instead)
1425
1426 - general: ProcessFile has been renamed to Process in all job classes,
1427 because ProcessFile is missleading
1428
1429 - general: The storage of the palette in MHCamera is now possible
1430
1431 - general: new bits describing unsuitable and unreliable pixels have
1432 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1433 kDeadPedestalRms, kFluctuatingArrivalTimes
1434
1435 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1436 versions newer than V200404070
1437
1438 - general: support for cc file versions newer than V200504130. Added
1439 support for active loads (MCameraActiveLoad) and central pixel
1440 (MCameraCentralPixel)
1441
1442 - general: added new histograms for image parameters versus size
1443 (MHVsSize)
1444
1445 - general: The eventloop now automatically calls PrintStatistics
1446
1447 - Status Display: Improved support for printing:
1448 + A default can now be set in .rootrc (for more details see
1449 MStatusDisplay::PrintPS)
1450 + A print dialog is opened so that printer and command line
1451 can be canged
1452
1453 - showlog: improved such that it handles different verbosity levels
1454 more accurate now. This mean you can suppress output when
1455 using showlog.
1456
1457 - showplot: improved
1458 + The new graphics formats have been implemented
1459 (pdf, svg, png, jpg and xpm)
1460 + Implemented an interface for printing. Because you can change
1461 the printing command from the command line you can use all
1462 the nice postscript tool. To print a booklet for example call:
1463 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1464 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1465 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1466
1467 - callisto: fixed a bug in the recognition of the calibration bit
1468 pattern. Concerns only intensity calibration. (The strength of the
1469 intensity has been updated in some cases)
1470
1471 - callisto: add a filter against PIN Diode events when running over
1472 calibration runs since some of the recent calibration runs have
1473 been taken with Pin Diode.
1474
1475 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1476 39943, 44833 in the calibration (MCalibColorSet)
1477
1478 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1479 been set to 1e-18 in callisto_Dec04_Jan05.rc
1480
1481 - callisto: in callisto_Dec04Jan05.rc: set value for
1482 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1483 statistics for the calculation of the mean pulse time
1484 of the cosmisc
1485
1486 - callisto: the charge limit in the calibration has been raised
1487 from 2.5 to 4.5
1488
1489 - callisto: new setup read from callisto.rc
1490 + MCalibCalcFromPast.fNumEventsDump
1491 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1492 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1493
1494 - callisto: MExtractTimeAndChargeSpline extractor:
1495 + The integration ranges were shifted by 0.2 FADC slices to the right.
1496 + unreliable handling of floating point values caused different
1497 results on different platform or with different compiler options:
1498 The new algorithm is numerically exact and more accurate because
1499 it doesn't calculate the integration position by multiple times
1500 adding the step-size (which results in numerical uncertanties
1501 exspecially if multiplied with large numbers)
1502 + A lot of fixes have been introduced which effects integrating the
1503 spline at the edges of the valid range. In this case any memory
1504 was randomly accessed. This behaviour can be tested replacing
1505 all MArrayF by TArrayF which perform a range check (but of course
1506 they are a lot slower)
1507 ! No result obtained with the Spline before can be trusted! Due to
1508 random memory access it might by completely random!
1509
1510 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1511 + extraction range in the high gain to 4.
1512 + weights file to cosmics_weights46.dat
1513
1514 - callisto:
1515 + introduce the check for fluctuating arrival times.
1516 + set charge limit to from 2.5 to 4.5
1517 + introduce asymmetric exclusion due to "deviating number of phes":
1518 Default: -9.0 +4.5
1519 + make deviating number of phes unsuitable (see David's findings).
1520
1521 - callisto: fixed the display of unsuitable pixels. The old change
1522 to a real profile in MHCamera broke it.
1523
1524 - callisto: The cosmics filter is used in MJCalibration now
1525 independant of the pulser color (formaly it was used only for
1526 CT1-pulser data). The threshold of number of max empty pixels
1527 has been raised from 2% to 5% in MJCalibration. The maximum
1528 fraction of rejected event is 50% otherwise the calibration has
1529 failed. The filter now ignores unsuitable pixels.
1530 Setup the filter from callisto.rc using "ContCosmics"
1531 (see MFCosmics::ReadEnv)
1532
1533 - callisto: changed default for fgOffsetFromLogain back
1534 from -2.8 to -1.8 in digital filter.
1535
1536 - callisto: for the common extractors
1537 + MExtractFixedWindow
1538 * MExtractTimeAndChargeSlidingWindow
1539 * MExtractTimeAndChargeSpline
1540 * MExtractTimeAndChargeDigitalFilter
1541 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1542 and fResolutionPerPheLoGain
1543
1544 - callisto: Updated the hi-/lo-gain intercalibration constants
1545 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1546 hilocalib_df6.root
1547
1548 - callisto: The default lo-gain extraction window for the
1549 MExtractTimeAndChargeSlidingWindow extractor has been increased
1550 from 6 to 8 to take the stretch of the pusle into account
1551
1552 - callisto (!!!): fixed an important bug in the setting of the
1553 incoming pedestal pointer to the signal extractor extracting
1554 pedestals. This bug caused the pedestals not to be subtracted
1555 correctly in the calibration afterwards. The effect was about 10%
1556 too high conversion factors for the digital filter and the spline
1557 and more than 40% for the sliding window.
1558 The bug existed since end of February! (Markus G.)
1559
1560 - star: added muon support to star. A new tab "MHMuonPar" is
1561 displayed. The lower right plot is an estimate of the point spread
1562 function. A reference value is displayed. To get the real PSF
1563 you must compare with MC. The setup for the muon analysis
1564 is done in star.rc. More informations can be found in
1565 MHSingleMuon and MHCalibParCalc
1566
1567 - star: The weather data is now displayed in star
1568
1569 - star: MEventRateCalc handles the calculation of the event rate more
1570 accurate now in case of the start of a new run inside a sequence
1571
1572 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1573 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1574 changed only minimally
1575
1576 - ganymed: (MJCut and MJOptimize) now displayes the number of
1577 excess events versus size. The energy estimation is done in
1578 MJSpectrum (sponde)
1579
1580 - ganymed: got support for using other variables than Alpha, eg. Theta.
1581 Therefor you need a class deriving from MHAlpha which supports
1582 this variable (one is already existing: MHTheta, which is now the
1583 default in ganymed). It is setup through ganymed.rc
1584
1585 - added a full featured spectrum program (sponde) which reads
1586 ganymed output and monte carlos and compiles a spectrum
1587
1588
1589
1590 *** Version 0.9.1 (2005/04/14)
1591
1592 - Fix bug on the arrival time reconstruction when using Digital
1593 Filter (in some marginal cases (10%) times were reconstructed shifted
1594 by 0.2 slices)
1595
1596 - all executables now return 2 where in previous versions -1 has
1597 been returned (gave problems with shell-scripts)
1598
1599 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1600 also done with a intercalibration input file
1601
1602 - a bug in the time fine adjustment of the digital filter has been fixed
1603
1604 - a lot of small fixes to calling TPad::Divide with a margin==0
1605
1606 - MStatusDisplay now shows the memory usage
1607
1608 - added a memory leak statistic after the eventloop
1609
1610 - MHadronness replaced by MParameterD
1611
1612 - MEnergyEst replaced by MParameterD
1613
1614 - wobble mode can now be switched on from the data-set
1615
1616 - switched on bad pixel detection for a pedestal level
1617 which is more than 5 times the variance
1618
1619 - Fixed default paths to be correct for the new data center
1620
1621 - Fixed handling of drive data. The pointing position in now
1622 copied to MPointingPos inside star for real and MC events
1623
1624 - made sure, that the sequences in a dataset are sorted by
1625 their number to ensure the correct synchronization
1626
1627 - added all resource files necessary to handle spline extraction
1628 of signal for the late 2004 and the early 2005 data
1629
1630 - update the reference lines for the december data
1631
1632 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1633 This is important for the Dec. and Jan. data where the calibration
1634 pulse position changes much.
1635
1636 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1637 filter. This corrects only an defective extraction of the MC at
1638 low-gain signals lower than 90 phes.
1639
1640 - fixed some slowdown in calibrating data with interleaved events from
1641 Jan and Dec. As a workaround made the pretty palette the default.
1642 The inverse Deep Blue Sea has a bug which slows down long calibration
1643 runs a lot.
1644
1645 - implemented new values from new starguider report as defined
1646 in TDAS00-07 V7.1 (eg SkyBrighness)
1647
1648 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1649 in starguider report (If you merpp the same reports with this version
1650 you'll get the correct units (arcmin) but a different result
1651 than with old versions (wrong units))
1652
1653 - Now the status display can also write PNG, JPEG and XPM (other file
1654 formats are still unsupported by root)
1655
1656 - added a lot of scripts and macros in directory datacenter used
1657 for automatic processing
1658
1659
1660
1661 *** Version 0.9 (2005/03/23)
1662
1663 - Calibration is now done autmatically into photo-electrons like
1664 decided by the Collaboration Board
1665
1666 - Reference lines in the display can be read from resource file
1667
1668 - Interlaced calibration events can be handled by callisto
1669
1670 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1671 and applied in callisto.
1672
1673 - class MJCalibTest can be called by callisto
1674
1675 - callisto can now run with three data types: rawdata, rootdata, MC
1676
1677 - added two classes mreport/MReportStarguider.cc and
1678 mreport/MReportStarguider.h for implementing starguider-data
1679
1680 - the output of merpp-update now contains starguider information:
1681 MReportStarguider and MTimeStarguider
1682
1683 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1684 values were lower than they should. This was more visible for high
1685 energy (Size) events.
1686
1687 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1688
1689 - added a new loop to callisto to support the correct extraction of
1690 the pedestal and pedestal rms through the signal extractor
1691
1692 - added class to perform fourier tranformation of a hexagonal structure
1693 (MHexagonalFT)
1694
1695 - added class to perform fourier tranformation of a hexagonal structure
1696 in a tasklist (MHexagonalFTCalc) example: hft.C
1697
1698 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1699 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1700 small pixels, example: extendcam.C
1701
1702 - added possibility to write data to memory (TTree) using MWriteRootFile
1703
1704 - added possibility to read a TTree stored only in memory by MReadTree
1705
1706 - new classes to deal with the interleaved calibration events:
1707 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1708
1709 - implemented filters to callisto to skip calibration events
1710
1711 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1712 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1713 the slices by statistics
1714 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1715 signal extractor without randomization
1716 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1717 with the signal extractor with randomization (extraction window is
1718 randomly fixed)
1719 The three kind of pedestal is not yet implemented (for speed reasons) as
1720 long as nobody really needs it:
1721 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1722 extracted with the signal extractor with randomization
1723
1724 - callisto now finds the pulse position in the data automatically
1725
1726 - implemented data reduction in calibrated data by reducing the precision
1727 of the stored floating point values (pedestal, rms and signal) to
1728 roughly 0.5%
1729
1730 - fixed showplot to make file format conversion (eg. converting a
1731 status display stored in a root file into a postscript file) in
1732 batch mode possible:
1733 showplot -b --save-as-ps[=outfile.ps] infile.root
1734
1735 - Allow class names as part of filter rules, eg
1736 (MFSupercuts) && (MHillas.fSize>100)
1737
1738 - fixed a lot of stuff to allow all programs to process MonteCarlo
1739 camera files.
1740
1741 - enhanced possibility to debug reading of resource file
1742
1743 - MDataChain should handle priorities of operator more
1744 accurate now
1745
1746 - completely revised the container in which the signal is stored
1747 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1748 * the new implementation is faster and
1749 * needs less storage space
1750
1751 - FIRST version which can process Monte Carlos through the
1752 whole chain of programs (callisto, star, etc)
1753
1754 - implemented new image parameters for the border length of
1755 the shower image (MNewImagePar2)
1756
1757 - implemented wobble-mode in ganymed
1758
1759 - new class (MJOptimize) taking care of all optimization processes
1760
1761
1762
1763 *** Version 0.8.6 (2004/10/05)
1764
1765 - New combined signal and time extractor
1766 MExtractTimeAndChargeDigitalFilter
1767
1768 - The Report for the trigger section in the CC run summary has been
1769 updated, and now the IPRs (Individual Pixel Rates) are available.
1770
1771 - new macros for database interaction: filldotrun.C, filldotrbk.C
1772
1773 - added new program which can convert colored output which was redirected
1774 into a file back into colored text (for example to display it with
1775 more): showlog
1776
1777 - added new program to display an MStatusArray of plots (stored with
1778 MStatusDisplay) from a file: showplot
1779
1780 - Added support for Sequences (MSequence). Sequences are blocks of run
1781 files containing the same calibration and belonging to the same
1782 source
1783
1784 - Added a new task (MTaskEnv) which can be used in setup files to switch
1785 between different tasks (for example to choose a signal extractor)
1786
1787 - Implemented automatic file splitting in MWriteRootFile
1788
1789 - After image cleaning an island index is assigned to all used pixels.
1790 The index corresponds to the order of the islands in size.
1791
1792 - added a cleaning which takes signal height _and_ arrival time into
1793 account: probability cleaning (for more details see MImgCleanStd)
1794
1795 - added a cleaning which takes takes the absolute number of photons
1796 times the area ratio as cleaning level
1797 (for more details see MImgCleanStd)
1798
1799 - Changed calculation of image parameters such, that it can be done
1800 for all used pixels or the pixels with a defined island index only
1801
1802 - implemented new image parameters displaying the number of islands,
1803 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1804
1805 - event display in executable changed to support also calibrated files
1806 (done with MJCalibrateSignal)
1807
1808 - added program doing the calibration and the signal extraction
1809 and signal calibration: callisto Most part of the setup is done
1810 by a resource file: callisto.rc
1811
1812 - implemented support for pixels with negative IDs (Raw file format
1813 version 4)
1814
1815 - implemented an new option in merpp (--auto-time) to get the time
1816 range for cc and/or caco data from the run header of the raw data
1817
1818 - New star-program (star and MJStar). Taking calibrated data from
1819 callisto/MJCalibrateSignal as input. The setup is done through
1820 a resource file: star.rc
1821
1822 - Added possibility to setup the eventloop in the mars-executable
1823 Camera Display by a resource file: mars.rc
1824
1825 - The the mars-executable Camera Display can now also read
1826 calibrated data files written by callisto/MJCalibrateSignal
1827
1828 - Added a new class which can calculate the source position in
1829 the camera from a pointing model known to be correct and
1830 the pointing model used for observations (MSrcPosFromModel)
1831
1832 - added a new version of the class calculating the effective on-time
1833 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1834 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1835 MHTimeDiffTheta.
1836
1837 - added the possibility to count how often a signal is above (or
1838 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1839 can replace MHTriggerLvl0)
1840
1841 - added ore convinient ways to set the axis-titles of your histograms
1842 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1843 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1844
1845
1846
1847 *** Version 0.8.5 (2004/08/06)
1848
1849 - new Signal Extractors: MExtractFixedWindowSpline
1850 and MExtractAmplitudeSpline
1851
1852 - implementes interleave in merpp to be able to merpp parts of a file
1853
1854 - implemented force-functionality to merpp
1855
1856 - star display to display star catalogs (MAstroCatalog)
1857
1858 - star display to 'mirror' stars to the camera (MAstroCamera)
1859
1860 - implemented a new cleaning option which allows cleaning scaled with
1861 the real ratio of the rms depending on the pixel size, not only the
1862 square root of the pixelsize (MImgCleanStd, MCameraData)
1863
1864 - removed obsolete MBlind* classes
1865
1866 - Signal extractor taking the AB flag into account implemented (this makes
1867 an odd number of slices for signal extraction possible
1868 (MExtractSignalABcorr)
1869
1870 - implemented a class extracting the pedestal from the raw-data (events)
1871 itself using empty lo-gain (MpedCalcFromLoGain)
1872
1873 - Added mean values to MPedPhotCam
1874
1875 - Added Makefile for Darwin (this OS is NOT officially supported!)
1876
1877
1878
1879 *** Version 0.8.4 (2004/04/19)
1880
1881 - new fast arrival time extractor using cubic splines:
1882 MExtractTimeFastSpline
1883
1884 - implementes multi-argument support in MDataChain
1885 ("pow(a, b)")
1886
1887 - implemented double reference support in MDataChain
1888 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1889
1890 - added support in MF for expressiond like
1891 "MHillas.fWidth<2*<MHillas.fLength"
1892
1893 - MDataChain is now able to support variables like [0], [1], ...
1894 which can be used in fit functions as parameters. The interface
1895 is implemented through the new virtual function
1896 MParContainer::SetVariables
1897
1898 - added new class MArrivalTimeCam/MArrivalTimePix:
1899 Storage containers to hold the ArrivalTime of the camera/pixel
1900
1901 - added new classes for the calibration of relative arrival times:
1902 MCalibrationRelTimePix and MCalibrationRelTimeCam
1903
1904 - added new classes to extract the signal of the blind pixel and the
1905 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1906
1907 - added new classes for the bad-pixels treatment (MBadPixels*)
1908 which are more powerfull than the old ones (MBlindPixel*)
1909 and will replace them.
1910
1911 - added filter against cosmics: MFCosmics
1912
1913 - added new class MArrivalTimeCalc2:
1914 Calculates the arrival time as the signal weighted mean of the time
1915 slices in the maximum window
1916
1917 - added a new macro call pointspreadfucntion.C that fits with a 2D
1918 gaussian the DC spot for an star. It gives you the RMS of
1919 the PSF and the center of the star, very useful for misspointing
1920 studies.
1921
1922 - added support for multi-telescope camera files. Added classes
1923 MStereoCalc and MStereoPar, classes to calculate and store shower
1924 parameters calculated from the data of two telescopes, for the MC
1925 studies regarding the MAGIC clone.
1926
1927 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1928 MC data calibrated in photons instead of ADC counts.
1929
1930 - added three macros to show the calibration and analysis chain of
1931 MC data. The macro starmc.C does both calibration and analysis, producing
1932 an output containing Hillas parameters for each event. The macro
1933 mccalibrate.C does just the calibration and writes out a file containing
1934 pixel information in photons instead of FADC data. The macro starmc2.C
1935 reads in such a file and produces an output with Hillas parameters.
1936
1937 - added MPedPhotCalc to compute pedestals in units of photons, see
1938 macro pedphotcalc.C
1939
1940 - added all class to perform the calibration, see macro calibration.C
1941
1942 - added class MFFT to perform Fast Fourier Transforms
1943
1944 - added class MSimulatedAnnealing to perform simulated annealing
1945 minimizations
1946
1947 - added new macro bootcampstandardanalysis.C which holds the skeleton
1948 of the analysis chain discussed in the december bootcamp.
1949
1950 - added support for DAQ raw data file format V2
1951
1952 - implemented an arbitrary time stamp for the events from raw-data
1953 files with file version<3. It is calculated from the run number,
1954 the date of start and the FADC clock tick from the first module
1955
1956 - implemented the correct decoding of the event time-stamp
1957 coming from the DAQ for raw-data files with file-version>2
1958
1959 - added a new classes storing the pedestals in units of photons:
1960 MPedPhotPix, MPedPhotCam
1961
1962 - added support for DC current files from the camera control
1963
1964 - added support for start- and stop-time when merpping report files
1965
1966 - added MReportCC storing the weather data from the CC-REPORT
1967
1968 - added class to fill trainings and test matrices (MTFillMatrix)
1969
1970 - added a filter performing a software trigger (MFSoftwareTrigger)
1971
1972 - Added classes to perform parts of the standard analysis (Jobs):
1973 + MJPedestals
1974 + MJCalibration
1975 + MJExtractSignal
1976 Note: All of them are preliminary!
1977
1978 - Added Iterator to iterate over files giving only the run-number
1979
1980 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1981 the evolution of a sector vs time
1982
1983
1984
1985 *** Version 0.8.3 (2003/12/05)
1986
1987 - adapted Random Forest classes to allow the use with MC
1988 multi-telescope files which can be produced with the coming
1989 camera version 0.7.
1990
1991 - added classes to read and interprete central control report files
1992 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1993
1994 - enhanced merpp (the executable) to support .raw and .rep files.
1995
1996 - added classes for light calibration (MCalibration* and
1997 MHCalibration*) by Markus Gaug. Further work has to be and will
1998 be done soon.
1999
2000 - Added a preliminary 'synchronizer' (MReadReports) which will
2001 replace MReadMarsFile as soon as it is finished.
2002
2003 - Added a tutorial macro demonstrating how report files are merpped
2004 and how they can be read from the root file in the correct order
2005 of time (readrep.C)
2006
2007 - Added a generalized histogram (similar to MH3) called MVsTime
2008 which allows to plot variables (or rules - MDataChain - of
2009 variables) vs time. For an example have a look at tempvstime.C.
2010
2011 - Changed the name of the event trees:
2012 + Events --> Events
2013 + PedEvents --> Pedestals
2014 + CalEvents --> Calibration
2015
2016 - changed name of MTime in the event trees from MRawEvtTime to MTime
2017
2018 - added displaying the sector indices to the mars event display
2019
2020 - Magic Online Analysis (MOnA) implemented in a first version
2021 (see mona.cc, MOnlineDump and MOnlineDisplay)
2022
2023 - added classes to calculate event rate
2024 (preliminary: MEventRateCalc, MEventRate)
2025
2026 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2027
2028 - added classes dealing with the telescope pointing position (MPointing*)
2029
2030 - implemented the 'final' Mars time stamp based on some experiences with
2031 the new 'Synchonizer'
2032
2033
2034
2035 *** Version 0.8.2 (2003/11/10)
2036
2037 - accelerated standard analysis by a factor of 6-8 ...
2038 + doing precalculations in MGeomCam for the pixel area ratio
2039 + creating a look up table for the single pixels in MCerPhotEvt
2040
2041 - added task to calculates weights in case you want to 'change'
2042 the energy spectrum of a monte carlo file
2043 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2044
2045 - added a new executable star which implements the
2046 star.C macro as precompiled executable. Currently a flexible
2047 setup is not possible, but a 'input card' setup will follow.
2048
2049 - Starting to implement Multi-Telescope-Support based on the
2050 upcomming camera version 0.7. The base for a general support
2051 is implemented and the star-functionality is proven to work.
2052
2053 - Replaced Event-Display in and Camera-Display in the Mars GUI
2054 executable by a more convinient display base on MStatusDisplay.
2055
2056 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2057
2058
2059
2060 *** Version 0.8.1 (2003/10/20)
2061
2062 - added signal subtraction for pure on data by means of fitting
2063 the background in the off region or by performing a combined
2064 signal/background fit. Provides necessary histograms for
2065 obtaining energy spectra and a light curve.
2066
2067 - added classes to perform and study the selection of the
2068 2nd Level Trigger on MC data (example in triglvl2.C macro)
2069
2070 - added pedestal calculation
2071
2072 - implemented "democratic cleaning" (tail cut value proportional
2073 to pixel area) according to Wolfgang's suggestion.
2074
2075 - added Sigmabar treatment (calculation and basic histogramming)
2076
2077 - added basic routines to apply padding
2078
2079 - added first implementation of MARS-based source visibility plotter
2080 (needs to be linked against slalib, preliminary version)
2081
2082 - enhanced functionality of data chains: random numbers, conversion
2083 functions and access to MHMatrix objects
2084
2085 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2086 numbers under certain circumstances (runs with 0 events included)
2087
2088 - fixed a bug in the general filter MF (didn't work on some systems
2089 at all)
2090
2091 - fixed a bug in chaining files, which caused the analysis to crash or
2092 ignore files
2093
2094 - implemented more geometry classes describing the parameters used
2095 to simulate the PMT camera
2096
2097 - added new Monte Carlo classes containing the setup of the different
2098 programs in the MC chain.
2099
2100 - added a (preliminary) general task to evaluate chi-square of a given
2101 parameter in an eventloop.
2102
2103 - first implementation of a container describing the observatory
2104 location (Long, Lat, etc)
2105
2106 - added Random Forest - method for g/h-separation
2107
2108 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2109 (this means, that it is compiling, but not yet fully tested)
2110
2111 - added a new status display which can show the present status
2112 of histograms while an eventloop is running (MStatusDisplay,
2113 an example can be found at status.C)
2114
2115 - reorganized directories:
2116 classes describing the image --> mimage
2117 classes containing Monte Carlo Histograms --> mhistmc
2118 classes for Random Forest method --> mranforest
2119
2120 - added (event-)weights to fill histograms
2121
2122 - colors in logging output to screen
2123
2124 - changes to the Image Parameter declaration:
2125 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2126 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2127 + MHillasExt now derives from MParContainer instead of MHillas
2128 --> Files written with the old definition are more or less unreadable
2129
2130 - reading of reflector files
2131
2132 - display data from reflector files in the camera
2133
2134 - implemented currents (and display them in the camera)
2135
2136 - logarithmic scale in camera
2137
2138 - added class to iterate through directory contents (MDirIter)
2139
2140
2141
2142 *** Version 0.8 (2002/11/18)
2143
2144 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2145
2146 - corrected 48(!) wrong entries in the Next Neighbor table of the
2147 Magic Camera (all in the inner part of the outer ring, mostly
2148 missing a single NN)
2149
2150 - Fixed a bug in the table describing the Next Neighbours of the
2151 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2152 have any neighbour)
2153
2154 - changed trigrate.C: now it calculates the pure NSB triggers from
2155 a camera file (generated with no showers), so there is no need
2156 to introduce them by hand in the BgR array (for more details
2157 please ask Abelardo)
2158
2159 - added MHHadronness (and MHadronness) as a general facility to evaluate
2160 the quality of a gamma-hadron seperation method
2161
2162 - changed MWriteAsciiFile to accept rules (MDataChain)
2163
2164 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2165 must be replaced by calles to MWriteAsciiFile::AddColumn and
2166 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2167 changed.
2168
2169 - Implemented generalized event-matrices (one row per event)
2170 (MHMatrix)
2171
2172 - implemented the one dimensional composite probabilities
2173 (MHCompProb, MCompProbCalc, comprob.C)
2174
2175 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2176 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2177
2178 - Added a camera display displaying the pixel numbers to the
2179 event display gui.
2180
2181 - Added Monte Carlo Informations to event display gui
2182
2183 - Changed the camera display to display the pixel numbering
2184
2185 - Added three buttons to the camera display to change the palette
2186
2187 - Added the number of used and core pixels after image cleaning
2188 to MHillas
2189
2190 - Changed the algorithm used in MHillas according to TDAS 02-03
2191
2192 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2193
2194 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2195
2196 - Added fCosDeltaAlpha to MHillasSrc
2197
2198 - The numbers of photons used to calculate fConc and fConc1 in
2199 MHillasExt are now scaled with the pixel size, so that one get
2200 a four times smaller value for the bigger pixels in the outer ring.
2201
2202 - added new task to smooth the camera contents (MCameraSmooth)
2203
2204 - added possibility to use interpolated pixel values for blind pixels
2205 instead of removing it completely from the analysis
2206
2207 - Implemented the possibility to save the whole eventloop with
2208 its setup to a file. This information can be read and from
2209 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2210 and MEvtLoop::MakeMacro. If you find something not working, please
2211 report - this stuff is still in a beta phase.
2212
2213 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2214 file having crab starfield, but also for all following files - fixed
2215
2216 - MTaskList::PrintStatistics can now be instructud to print also the
2217 title, too: use PrintStatistics(0, kTRUE)
2218
2219 - Changed the image cleaning so that pixels with to many 'used'
2220 neighbors are left used (to get rid of 'holes' in events)
2221
2222 - Introduced more output to the camera displays
2223
2224 - Added an array of histograms (eg one hist per run), MHArray
2225
2226 - Added a _preliminary_ version of the reader for CT1 PreProc files
2227 (MCT1ReadPreProc)
2228
2229 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2230 (thanks to Raquel)
2231
2232 - added the first energy estimator (MEnergyEstParam, estimate.C,
2233 estfit.C) using a parametrization
2234
2235 - Added some new Monte Carlo paremeter containers used to store
2236 setup information from the MC chain (MMcConfigRunHeader,
2237 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2238
2239
2240
2241 *** Version 0.7 (2002/04/30)
2242
2243 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2244 the pedestal mean value was saved incorrectly. For files from
2245 this versions we substract 0.5 from the pedestal mean.
2246 WARNING: This may effect your results, so don't wonder...
2247
2248 - First implementation of an algorithm using only triggered events
2249 for the collection area calculation
2250
2251 - Ascii Output can now also be used for parameter containers which
2252 doesn't overload MParCointainer::AsciiWrite
2253
2254 - The Ascii Output is now also capable of writing single data members
2255 of one container
2256
2257 - You are now able to change the order of the values written to the
2258 ascii file
2259
2260 - You can now specify a conversion factor for each data member written
2261 to an ascii file. This may be usefull to change the units of the
2262 data member (eg. degrees instead of millimeters in case of the
2263 hillas parameters)
2264
2265 - Replaced old MHillas by a new structure which allows you to extend
2266 the parameters stored in MHillas very easily:
2267 see MHillas and MHillasExt
2268
2269 - Added classes to handle source dependancy of image parameters:
2270 see MHillasSrc
2271
2272 - Added container (MBinning) to have a standard input for the binning
2273 in different histograms (eg. the Energy bins should be the same in
2274 all histograms)
2275
2276 - Changed Hillas histograms from mm to deg
2277
2278 - Added the flexible binning to the hillas histograms
2279
2280 - Added a filter for the alpha parameter (MFAlpha)
2281
2282 - It is now possible to write single data members of a class object to
2283 an output stream instead of the whole container only
2284
2285 - Added a generalized filter for a data member:
2286 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2287
2288 - Added a generalized Filter parser for more difficult filter rules
2289 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2290
2291 - Added new Monte Carlo histograms:
2292 MHMcEnergyImpact and MHMcEfficiency
2293
2294 - Added many new histograms needed for the flux calculation.
2295
2296 - Added a generalized histograms which can fill and show up to three
2297 data members in either a one-, two- or three-dimensional histogram, eg:
2298 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2299
2300 - Added:
2301 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2302 * calculation of <Theta> as a function of time (MHThetabarTime)
2303 they are needed in the flux calculation in
2304 order to select for a given bin in Theta (or time) the appropriate
2305 effective collection area, which is assumed to be given as a function
2306 of Theta and the true energy
2307
2308 - Added calculation of the migration matrix in the energy
2309 (MHMcEnergyMigration):
2310 the migration matrix describes the migration from the true (E_true)
2311 to the estimated energy (E_est); it is needed to determine the
2312 distribution of E_true from the measured distribution of E_est
2313 by unfolding
2314
2315 - changed the color palette in the camera display to DeapSea.
2316
2317
2318
2319 *** Version 0.6 (2002/01/15)
2320
2321 - Introduce the option of disable pixels (MBlindPixels and
2322 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2323 able to deal with Star Field NSB.
2324
2325 - Fixed a bug in the pedestals substraction
2326
2327 - Introduced verbosity levels
2328
2329 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2330
2331 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2332 work correctly (thanks to Abelardo)
2333
2334 - Introduced correct treatment of the diffuse Night Sky Background
2335 and NSB (MMcPedestalNSB)
2336
2337 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2338
2339 - Introduced MMcRunHeaders which contains monte carlo run informations
2340
2341 - Added a 'Print'-Task (MPrint) which calls the Print function
2342 of a parameter container for each event
2343
2344 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2345
2346 - changes to be more efficient with root 3.02/06
2347
2348 - root 3.02/06 fixes:
2349 + the memory leak when reading MRawEvtData
2350 + loosing more time than necessary to update the progress bar
2351
2352 - MWriteAsciiFile is now capable of writing more than one container
2353 in a line. For example: To be able to write Monte Carlo and
2354 Hillas values (energy and alpha) in one line.
2355
2356
2357
2358 *** Version 0.5 (2001/11/06)
2359
2360 - Added new GUI functionality (Analysis)
2361
2362 - Added a camera display to be able to display events in the camera
2363 together with the calculated hillas ellipse
2364
2365 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2366 object at any state of the analysis, so that the output are several
2367 states
2368
2369 - Fixed a bug in the collection area error calculation
2370 (Thanks to Ciro and Abelardo)
2371
2372 - Fixed a bug which causes merpp to crash in some environments
2373
2374 - Implemented auto enabling scheme for Branches to speed up reading
2375 a lot (see MReadTree and MTask)
2376
2377 - Fixed a bug in the Histogram classes which caused histograms to
2378 be written to a file by MWriteRootFile without request
2379
2380 - changed the object I/O from the old stylish root I/O to the new
2381 'auto evolution scheme' This was done only for classes which are not
2382 yet used in Monte Carlo files, so that these files are still readable.
2383
2384 - Added support for a progress bar in MEvtLoop and MReadTree
2385 (see the Analysis Window in Mars for an example)
2386
2387 - Fixed a bug in the package creation which disturbed the conversion
2388 between a mars version unpacked from a tar file and the repository.
2389
2390 - Changed the code to writer merpped (converted into root format)
2391 raw files, to get faster (around 10%)
2392
2393
2394
2395 *** Version 0.4 (2001/09/20)
2396
2397 - This release is made to compile on a root version >= 3.00
2398
2399 - Fixed a bug which causes MReadTree to read the first file only
2400
2401 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2402
2403 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2404
2405 - Added a task to write several container to a root file (MWriteRootFile)
2406
2407 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2408
2409 - Added calculation of the collection area (MMcCollectionAreaCalc)
2410
2411 - fixed some bugs in the Hillas calculation
2412
2413 - added filters to be able to control the task execution dependent on
2414 a parameter (for example: the number of level 1 triggers in a MC-file)
2415
2416
2417
2418 *** Version 0.3 (2001/04/23)
2419
2420 - Many demo macros added
2421
2422 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2423
2424 - Hillas Calculation added
2425
2426 - Standard image cleaning available
2427
2428 - MReadTree is now able to handle more than one file
2429 (Remark: of the same structure)
2430
2431 - Now we are able to display events in a first version of the
2432 Camera event display. To do this we must run the macro
2433 "macros/readCT1.C" to read data from CT1.
2434
2435
2436
2437 *** Version 0.2 (2001/01/24)
2438
2439 - First Implementation of a Gui to read the raw data. Start the
2440 gui with the command mars.
2441
2442
2443
2444 *** Version 0.1 (2000/12/20)
2445
2446 - First official release 0.1
2447
2448 - Changes:
2449
2450 + changed calling style of MRawPixelIterator from do...while to
2451 while-loop
Note: See TracBrowser for help on using the repository browser.