source: trunk/MagicSoft/Mars/NEWS@ 8670

Last change on this file since 8670 was 8670, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 104.4 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Now the output files (calib*.root, etc) also contain the
11 resource file (to check it open it in the TBrowser and choose Print()
12 from the context menu)
13
14 - general: Dataset files now allow to overwrite the default path
15 to search for sequence and data files. Note, that the program
16 option and individual resources will overwrite it. For example:
17 SequencePath: /magic/montecarlo/sequences
18 DataPath: /magic/montecarlo/star
19
20 - general: Fixed a problem with variables in MDataPhrase. It seems
21 that only optimdisp (didn't work) was effected.
22
23 - general: Some improvements to the optim and train processing. For
24 example the ststud window now got a proper title.
25
26 - general: The "Status Display: " was removed from the window title
27 within an Eventloop.
28
29 - merpp: Merpp can read file format version 9 now. Please realize
30 that for file format version 9 the extraction range is different
31 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
32 the first and last 15 slices have been removed from all MUX data.
33
34 - mars: Similar to writing movies you can now select events which
35 should be displayed in your display. Therefore add the following
36 lines to your mars.rc:
37 MFEvtNumber.FileName: ganymed00223552.root
38 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
39 The input file can be a ganymed-file after (ganymed*.root) or
40 before (ganymed*-summary.root) file. For example to select all events
41 from your on sample after cuts (excluding the ThetaSq cut) use
42 MFEvtNumber.Selector: DataType.fVal>0.5
43 To show all events from your on-sample after quality cuts
44 use the summary file instead.
45
46 - mars: new ways to call mars are implemented. Instead
47 of calling
48 mars filename.root
49 you can now also use
50 mars sequence.txt
51 or
52 mars sequence.txt inputpath
53 or replace sequence.txt by the sequence number if the default
54 sequence file should be used.
55
56 - mars: The default size has been increased
57
58 - mars: There are two new heckboxes which allow to switch off
59 the calculated image parameters
60
61 - callisto: was broken for MCs... fixed.
62
63 - callisto: improved calculation of spline coefficients a lot. This
64 leads to a further improvement of the event rate calibrating MUX
65 data of about 15% (175evt/s instead of 150evt/s)
66
67 - callisto: finally the raw data we read is now real 16bit (with
68 10bit precision) for MUX data and not a stripped 8bit number
69 anymore. Due to scaling of the numbers (without precision loss
70 into an [0-256[ range, the final numbers for pedestal, pedestalrms
71 and extacted signal don't change. However, at all places where
72 raw data is directly accessed (eg. saturation and variation
73 limits in the signal- and pedestal-extraction) the numbers
74 refer still to the data's 16bit range.
75
76 - callisto: The maximum arrival time difference used in the bad
77 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
78 for both, old FADC and MUX-FADC, data.
79
80 - callisto: Be aware that callisto is now calibrating the arrival time
81 in nanoseconds rather than time slices. Also all following tasks
82 have been changed to assume ns units now. If you star data
83 calibrated with an older version it might be necessary to adapt
84 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
85 to obtain optimal results. The plot in the PulsePos tab
86 will now be in ns, too. This might also mean that the Muon
87 analysis in star might not work as perfect as expected as long
88 as old files read in.
89
90 - star: For speed reasons events suitable for the muon analysis
91 are now also preselected by fConcCOG<0.1 which seems to be a very
92 good preselector for muons.
93
94 - star: is now calculating a new timing parameter the Slope along
95 the major and minor axis of the shower. Therefore a numerical
96 solution of a line-fit is used. To use MHillasExt.fSlopeLong
97 and MHillasExt.fSlopeTrans don't forget to multiply it with
98 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
99
100 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
101 have been removed from MNewImagePar. They have never been good for
102 anything.
103
104 - star: Implemented a new recursive algorithm which is supposed to be
105 faster. Also implemented new cleaning oiptions, which are:
106 + CleanLevel0:
107 The cleaning level above single core pixels can be kept
108 + KeepIsolatedPixels:
109 Define whether single core pixels should be kept
110 + TimeLevel1:
111 The coincidence window in nanoseconds to single used neighbors
112 + TimeLevel2:
113 The coincidence window in nanoseconds to two used neighbors
114 + PostCleanType:
115 MOde in which a time dependent post cleaning should be applied
116 0: No post cleaning
117 1: Require for each used pixels at least one used neighbor
118 within a time-window of CleanLevel1
119 2: Require for each used pixels at least two used neighbor
120 within a time-window of CleanLevel2
121 3: Require first two and second one used neighbor
122 within a time-window of CleanLevel1 and fCleanLevel2
123 respectively
124 + RecoverIsolatedPixels:
125 - recoveres isolated core pixels if they have a used neighbor
126
127 - mars/star: The new default cleaning is:
128 + CleanLevel1: 6.0
129 + CleanLevel2: 3.0
130 + CleanTime1: 1.75
131 + CleanTime2: 1.75
132 + PostCleanType: 3
133
134 - star/ganymed: The old spark-cuts have been replaced by new ones.
135 These new spark cuts have been cross checked with the sequences
136 84720 (before splitter), 101041 (after splitter) and 223539 (new
137 FADCs). In all cases they seperate pretty well, but of course not
138 perfect. Monte Carlos have suggested to tighten the cuts a little
139 bit further at low sizes. This has been done.
140
141 - ganymed: The old hadronness and size cuts have gotten new indices
142 (10, 11). The old indices 8 and 9 now mean an additional condition
143 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
144 If you want to switch off this cut just move the line far away enough,
145 e.g. by setting c[9] to -500. Please update your ganymed.rc files
146 accordingly!
147 The unit of c[9] is deg. It is the dist at which your cut will
148 cross the slope==0. The unit of the slope is ns/deg. So if
149 you readin files calibrated with an older Mars-version you
150 have to adapt the default value for c[9] to the FADCs:
151 - Multiply by two for the MUX FADCs (run number > 200.000)
152 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
153 - Multiply by 42 for the meaning of life (run number = 200.000)
154
155 - ganymed: The old Cut0 is now called CutQ and is calculated before
156 the source position is caluclated. If you need a quality cut
157 including source dependant data (be very carefull with this!)
158 you have to use Cut0 instead.
159
160 - ganymed: now properly supports three off regions in wobble mode.
161 It will be the default from now on in ganymed_wobble.rc. To change
162 the number of off-regions use
163 NumOffSourcePositions: 1
164 in your ganymed.rc. Also by default no off-theta cut will be done
165 anymore so that you will get a background level higher than the
166 signal level in your ThetaSq plot for ThetaSq>0.2.
167 Due to this be carefull changing the scaling mode away from
168 "None". You will underestimate your signal if your scale interval
169 is not properly set.
170 (Rem: ThetaSqN is no longer needed)
171
172 - ganymed: is now storing the events of all source (on- and off-
173 source positions) even in the case of more than one off-source
174 position. This should allow sponde to work properly and the
175 energy estimation is done correctly in all cases (without any
176 "nearest position" trick)
177
178 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
179 with a real pointing model for the starguider is done, calibrated
180 with more than thousand tpoints taken from this date on.
181
182 - ganymed: was broken for Wobble-MCs... fixed.
183
184 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
185 has changed. Note that your old ganymed.rc will be incompatible
186 with the new algorithms! Please check the ganymed.rc files and
187 the class description of MFMagicCuts for more information.
188 It is recommended at the moment to use identical Disp-Parametrizations
189 for on/off- and wobble-mode. If cuts are optimized only
190 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
191 should be optimized. All other values should be kept as they are.
192 If you want to do an anylsis without timing a parameters, you can
193 switch off the timing cuts by seeting parameter 7 to a very small
194 value (eg. -99). To remove the slope parameter from the disp
195 paremtrization set parameter 8 to 0.
196
197 - ganymed: IMPORTANT - The spark cuts have been removed from the
198 resource files because there is currently no proper known
199 cut. Whenever you do an analysis you have to find proper cuts
200 yourself!
201
202 - ganymed: The distribution of observation time versus zenith
203 angle is now shown for off- AND on-data.
204
205 - optim, sponde: should now properly support three off-regions.
206 Just produce your ganymed summary files with three off-regions.
207 optim and sponde will automatically get all off events from
208 all off-regions from this file. Please do not forget to
209 set the scaling in optimwobble.C properly:
210 fit.SetScaleMode(MAlphaFitter::kNone);
211 fit.SetScaleUser(1./3);
212 it is not yet read in automatically (will follow soon).
213 In the case of fixed Scale you can also use
214 cuts.SetThetaCut(MFMagicCuts::kOn);
215 no off-cut needed.
216 Be carefull in case of three off-regions when switching on
217 scale mode. Make sure that the scale interval is set correctly.
218
219 - sponde: In the estimated energy versus monte carlo energy plot the
220 contents where exchanged.... fixed.
221
222
223
224 *** Version 1.2 (2007/05/14)
225
226 - database: The database now has two new values Unsuitable50 and
227 Unsuitable01. They express the number of pixels which are
228 unsuitable for more than 50%, respectively more than 1%, of
229 all calibrated event. It is a more accurate number than the
230 previously used numbers, because they only take the first
231 calibration (ignoring the interleaved calibrations) into account.
232
233 - database: The database now has two other new values UnsuitableMax and
234 DeadMax. They express the maximum number of pixels which were
235 unsuitable, respectively dead, during the sequence. Because
236 of high pedestal rms (cars passing) a few events with very high
237 numbers of unsuitable pixels can happen. Not to suffer from this
238 effect we don't take the highest 0.1% of the numbers into account.
239
240 - general: fixed a bug which caused callisto and star to stop working
241 properly because the callisto output was currupted
242
243 - general: a script called scripts/makemovie has been added which
244 simplified the process of producing several movies from a single
245 sequence with different setup.
246
247 - callisto: Some more code cleanup. Started to remove old obsolete
248 code from cvs.
249
250 - callisto: The extraction of the pedestal with the extractor was
251 not random. It seems that extracting at one position is still biased
252 (for example in the first or last slices we could still suffer from
253 switching noise) Now it is completely random.
254
255 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
256 pedestal files) individual pixels could be skipped due to high
257 variations. This was already the case for the pedestal extraction
258 from the lo-gains since the beginning and properly handled
259 there, but was introduced in the extraction from the pedestal files
260 a while ago. To calculate the average value it was still divided
261 by the number of events procesed not by the number of summands
262 really summed. This let to a pedestal which was a tiny amount too
263 small (for a few piels in the order of 0.1%). This led to an slightly
264 positive offset of the randomly extracted pedestal for a few pixels.
265 I doubt that this has a big effect on the result, because the effect
266 on the individual numbers is quite small. Due to this it is suggested
267 that you rerun your calibration to make sure you are without any
268 avoidable bias.
269
270 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
271 the median rms of the absolute arrival time and expressed in significance
272 levels. This replaces the old meaning of an abolute upper limit. An
273 absolute upper limit doesn't make much sense, because in our data
274 all arrival times are shifted at the same time (in fact it might be
275 a shift of the artificial trigger w.r.t. to the light flash).
276
277 - callisto: Added a new tab "BadPixTm" which shows the time evolution
278 of the number of unsuitable pixels over the whole sequence. This
279 is usefull mainly to judge if an intermediate calibration had
280 problems.
281
282 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
283 of the number of dead pixels over the whole sequence. Dead pixels
284 in this context are unmapped pixels, i.e. pixels which could not
285 be interpolated, and thus are ignored in the further analysis.
286
287 - callisto: It is now possible to use the position of the maximum
288 of the spline as arrival time instead of the leading edge even
289 when using the integral for the signal. Therefor set the extraction
290 type to kIntegralRel ("IntegralRelative") and the relative height
291 ("HeightTm") to -1:
292 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
293 MJPedestalC1.ExtractSignal.HeightTm: -1
294
295
296
297
298 *** Version 1.1 (2007/04/27)
299
300 - general: The new class MGeomCamDwarf contains the camera geometry
301 for our prefered Dwarf camera and can be used to create general
302 geometries of roundish or hexagonal cameras.
303
304 - mars: The default cleaning is now abolute 8.5/4.0.
305
306 - mars: The resource file mars.rc now contains examples for MUX data
307
308 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
309 data containing only 10-bit information is still cooked down to
310 8-bit, by cutting away the lowest 8-bit.
311
312 - merpp: When reading raw data the data is now stored in a single
313 array. The lo-gain array is obsolete. The interface stays the same.
314
315 - callisto: To process the new MUX data use the resource file
316 callisto_mux.rc
317
318 - callisto: The -root and -raw options to read merpped raw data have
319 been removed
320
321 - callisto: If the -mc option is given the sequence-name can now be
322 replaced by the MC sequence number
323
324 - callisto: If the sequence file contains "MonteCarlo: Yes" the
325 -mc option can now be omitted
326
327 - callisto: Started further simplification by removing obsolete
328 dependancies on MCalibIntensity*Cams.
329
330 - callisto: removed unsused intensity calibration from MJCalibration
331 for further simplification
332
333 - callisto: for simplification removed references to
334 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
335 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
336 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
337 (this should at minimum change nothing at all, and at maximum
338 improve thing if these containers where somewhere not handled
339 properly)
340
341 - callisto: Added the option to write an event movie. Please use
342 this option with care (huge files) but exessively to understand
343 our events. For further documentation please refer to the
344 IACT wiki
345 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
346
347 - callisto: Improved binning for the pulse position check histogram
348
349 - callisto: The code calculating the pulse position checknow takes
350 the pedestal into account
351
352 - callisto: The arrival time is now stored with full precision this
353 helps to get rid of artefacts in histograms. For the signal this
354 is not necessray because it is displayed in log-scale anyhow
355
356 - callisto: Fixed a problem with internal exclusions. Pixels which
357 have once been marked as unsuitable didn't get the necessary
358 histograms filled anymore to be rechecked with each interleaved
359 calibration.
360
361 - callisto: The relative arrival time resolution (the rms of the
362 relative arrival time offset) is now checked against its
363 median and the median deviation, instead of the average
364 plus an absolute offset.
365
366 - callisto: The relative arrival time offset is now calculated
367 w.r.t. its median not w.r.t. to an artificial reference pixel.
368
369 - callisto: The relative time calibration now marks pixels with
370 outlaying offset as unsuitable
371
372 - callisto: The interleaved relative time calibration has been switched
373 on. The advantage is that pixels which are marked as outliers
374 now can recover. An improvement over time is not expected, because
375 the relative time calibration seems stable.
376
377 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
378 option can now be omitted.
379
380 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
381 or the option "-mc" is specified as default the monte carlo datacenter
382 paths (/magic/montecarlo/...) are used if not overwritten in the
383 dataset file.
384
385 - ganymed: The output files now contain run- and event-number for all
386 events, accessible as RunNumber.fVal and EvtNumber.fVal
387
388 - ganymed: Added a plot showing the source position in the camera also
389 for wobble mode
390
391 - ganymed: In addition to the existing task which can be setup to
392 be executed after Cut1 a final task called "EstimateEnergy"
393 has been added, executed before writing the final output
394 (ganymed00000000.root). The task setup in all three cases
395 can be choosen individually. (For all three(!) cases you
396 can for example choose MRanForestCalc. For examples see all
397 sponde*.rc and all ganymed*rc)
398
399 - ganymed: If a container "MEstimatedEnergy" is found in the
400 parameter list (eg. because it was setup by MEstimateEnergy)
401 it will be written to the output file.
402
403
404
405 *** Version 1.0 (2007/02/16)
406
407 - database: Website to plot values from the database has been added.
408
409 - database: The rate of spark events as found by star is now kept
410 and the rate after cleaning is now with spark events subtracted
411
412 - general: The changes to the interpretation of phrases lead to
413 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
414
415 - general: Added example files how you can create your own calendar
416 (eg. as christmas present) with Mars. Just run
417 root macros/tutorials/calendar.C
418
419 - general: Added a possibility to display grouped data in the plotdb.C
420 macro (and similar macros). This allows to plot hourly, nightly,
421 weekly, monthly and yearly averages.
422 For more details see the plotall function of the macro
423
424 - general: fixed the error display of the camera display. It showed
425 wrong results.
426
427 - general: fixed a memory leak when reading many MStatusDisplays
428
429 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
430 between a spherical and a parabolic mirror
431
432 - callisto: We have a new pulse position check which takes the properties
433 of the extractor automatically into account. So no need to set
434 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
435 left is done. If possible the lo-gain extraction start and hi-gain
436 extraction end is changed accordingly. If no proper extraction range
437 can be set (hi-gain too much to the left) an error is raised.
438
439 - callisto: New swapped pixels have been found and corrected
440
441 - callisto: Redone the signal extraction this includes:
442 + Unified the algorithms to extract the pedestal for all pedestal
443 extractions done
444 + Unification of hi- and lo-gain into one array
445 + Unification of hi- and lo-gain extraction for Spline and
446 Digital Filter (means now exactly the same algorithm is used,
447 not a copy-and-pasted one)
448 + Store pedestal subtracted data in a common place
449 + Improved extraction algorithms. If the algorithms search a
450 maximum but don't find one they don't return the maximum anymore
451 + Improved the extraction such that a information for signal
452 and time which is consistent is returned
453 + replaced the numerical spline with a (not slower) analytical
454 solution
455 + Lowered the saturation limit from 250 to 245 to make sure that
456 we are far away in all pixels from problems with the clock-noise
457 + The start of the lo-gain extraction is calculated from the hi-gain
458 arrival time. In case of saturation an estimation is used.
459 + the hi-gain window was extended to slice 16. This allows extraction
460 of very late pulses in single pixels or of huge hadron showers.
461 + Now uses the lo-gain extraction range for pedestal extraction,
462 not the hi-gain range in the lo-gain
463
464 - callisto: New hi-/lo-gain calibration constants have been produced
465 for all periods from the statistic of the whole period. They are
466 now used automatically depending on the periods. The old constants
467 where deviation in avarega about 2%-3%. The constants are very
468 stable from period to period (<<1%) except for exchanged channels.
469 In a few cases the constants used so far were off by 1%-2% (maybe
470 temperature effects?)
471
472 - callisto: To gain obsolete space we do not write the
473 MPedestalFundamental anymore. Also calibration and bad pixel
474 treatment is not done for it anymore because it has never been used.
475
476 - callisto: Fixed a bug in the seuqence handling which caused the
477 light condition to be ignored
478
479 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
480 basically the same as "Cleaned" but the distribution devided into
481 the events fullfilling a spark cut or being rejected by it.
482 This cut can be changed from star.rc (see example inside) by
483 the "SparkCut" directive
484
485 - star: Star displays now the average individual pixel-rate (IPR) versus
486 time and the average discriminator threshold (DT) of all pixels.
487
488 - optim: fixed a problem with the optim-macros which was due to a bug
489 in the new phrase parsing
490
491 - ganymed: To get a nice FalseSource plot (instead of the all-information
492 debug plot displayed as a standard plot) use the context menu
493 somewhere between the two upper plots, click on "DrawNicePlot"
494 and enjoy the result. (It is the same context menu which contains
495 the other options)
496 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
497
498 - ganymed/optim/train: The cut program, trainings- and optimization
499 macros could run with less files found than expected from the
500 sequence-files. No the execution is stopped in this case.
501
502 - ganymed: now stores the dataset in the output file with all information
503 contained (as sequence number, sequence path, data path) so that the
504 used dataset file can be recreated complete from the output
505
506 - sponde: now also allows the uasge of random forest
507
508 - sponde: added a plot showing the cut efficiency
509
510 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
511 errors (eg. effecting the collection area) because the errors of the
512 two histograms were swapped in the calculation, which makes a difference
513 in the case the histograms contains weighted events. Aditionally the
514 totalarea was incorrectly taken into account, which results in too small
515 errors, which makes a difference at low statistics were the errors
516 or the collection area dominate.
517
518
519
520 *** Version 0.10.3 (2006/10/23)
521
522 - database: Implemented ObservationMode flag in websites.
523
524 - database: For sequences there is now also the stoptime available on the
525 websites.
526
527 - database: Removed ManuallyChanged flag from sequence-info websites,
528 as it is not needed anymore with the new sequence building algorithm.
529
530 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
531 Class for calculation of confidence intervals (upper limits).
532 Use model 3 or 4 for upper limit calculation for MAGIC observations.
533 Please read the class instruction of TRolke for more information.
534
535 - general: The programs now return 0xfe if the requested resource file
536 doesn't exist.
537
538 - general: Errors comming from root itself are now not output to
539 stderr anymore but to our default (colored) log-stream.
540
541 - general: Changed the interface to TFormula such that now everything
542 is parsed by TFormula, which should allow to use phrases even
543 without paranthesis correctly parsed.
544
545 - callisto: replaced the AdHoc number of effective integration slices
546 in the digital filter by an average of the correct number, averaged
547 over all possible set of weights. This also gives correct numbers
548 for the lo-gains which were totally wrong before.
549
550 - callisto: drastically reduced memory consumption by not storing
551 all intermediate calibration results in memory anymore (we might
552 write them into a file in the future)
553
554 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
555 debug plot displayed as a standard plot) use the context menu
556 somewhere between the two upper plots, click on "DrawNicePlot"
557 and enjoy the result. (It is the same context menu which contains
558 the "DrawAll" option)
559 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
560
561
562
563 *** Version 0.10.2 (2006/10/15)
564
565 - general: changed the building of the sequence files such, that
566 the source-/project name in case of wobble-sources is not the
567 source/project of the first data run anymore but the new generalized
568 wobble source/project
569
570 - general: Added some functions to MAstro to calculate sun and
571 moon properties
572
573 - general: Added two new macros (starvisday.C and starvisyear.C)
574 which allow to plot the visibility of several stars in one day
575 or of one star along one year
576
577
578
579 *** Version 0.10.1 (2006/10/11)
580
581 - general: HTML logging output was distorted... fixed.
582
583 - general: Changed the writing of the sequencefiles such that only
584 as many pedestal files as giving at least 1000 pedestal events which
585 are nearby the first calibration run are used as pedestal runs
586
587 - sponde: In the calculation of the collection area(s) and the
588 distribution for MOnte Carlo and estimated energy the error
589 calculation was wrong because root didn't take the errors
590 properly into account... fixed.
591
592
593
594 *** Version 0.10 (2006/10/10)
595
596 - general: all executables now check consistency of the root version
597 installed with the root version used for compilation. The return
598 code in this case is 255.
599
600 - general: The algorithm to build seqeunces has been redesigned
601 completly. It is now more flexible in terms of a resource file
602 resources/sequences.rc which can be used to partly overwrite
603 the default algorithm and defined the important part of the
604 algorithm. It also takes correctly into account several ways
605 of taking wobble-data. Currently the new algorithm doesn't take
606 the number of pedestal events anymore into account (so a sequence
607 could have much less than 1000 pedestal events and data runs are
608 no-more used instead)
609
610 - general: a lot of small changes to make the code compatible with
611 root 5.12/00 and gcc 4.1
612
613 - general: Fixed some warnings thrown if more warnings are switched
614 on in the compiler
615
616 - general: Added a function to MMath which returns the Median of
617 the distribution abs(y[i]-median) but at 68:32 division instead
618 of 50:50, which is somehow the median counterpart of the rms.
619
620 - general: MAstroCatalog allows now to read calatog files (as bsc5)
621 even if they are compressed with gzip (recommended compression
622 is with "-1")
623
624 - showplot:
625 + batch mode creation of image files now works with root 5.12/00
626 + added support for writing bmp (though it never produces
627 bmp which can be read by programs like xv or gimp)
628 + added support for xml
629 + added new option to start the display with a different size, by
630 --display-width=nnn or --display-height=nnn
631 + added options to define the canvas size when the display is started
632 --canvas-width=nnn or --canvas-height=nnn
633 the option can also be used for batch-mode conversion
634 + added an option which automatically fits the display size to the
635 desktop-size: --auto-size
636
637 - merpp: didn't recognize files with the extension .raw.gz - fixed.
638
639 - merpp: allow the reports to have 1000ms due to a bug in the camera
640 program.
641
642 - callisto: New swapped pixels have been found and corrected. For
643 details see MRawRunHeader::FixAssignment()
644
645 - callisto: Callisto now raises an error if one of the input files could
646 not be opened.
647
648 - callisto: In some rare cases it could happen that in the signal
649 extraction of the digital filter the extractor returned nonsense
650 results due a wrong initializion of a variable (this happens in
651 cases in which the extracted signal is exactly zero or the
652 digital filter couldn't slide because of a too small extraction
653 window, which could happen in the lo-gain extraction)
654
655 - callisto: The lo-gains have been marked as valid in some cases
656 when they got not extracted at all (deltsumlo=deltatimelo=0) because
657 the allowed extraction range (fLoGainLast-fLoGainFirst) was
658 smaller than the number of slices (fLoGainWindowSize) needed
659 by the lo-gain extractor
660
661 - callisto: Updated absolute calibration constants (muon calibration)
662
663 - callisto: fixed a bug which caused the hi-gain saturation not
664 to be handled properly in the spline (the position of the
665 saturation was calculated incorrectly)
666
667 - callisto: fixed a bug which gave weird results if hi- _and_
668 lo-gain could not be extracted properly. In some cases hi-
669 and lo-gain have not been extracted at all and the random result
670 got calibrated. In other cases the hi-gain was saturating and the
671 lo-gain has not been extracted. For this a completly arbitraty
672 scale factor was applied to the result from extracting the
673 charge of the saturating hi-gain.
674
675 - callisto: improves handling of extracted signal if lo- and/or
676 hi-gain could not be extracted properly. If no appropriate
677 calibration of either the signal or the arrival time is possible
678 the pixel is now markes as unsuitable instead of estimated.
679
680 - callisto: Fixed a problem in the spline extraction which gave
681 weird results if the signal was extracted from the first (and
682 highest) slice (as a workaround extraction from the first
683 slice has been forbidden)
684
685 - callisto: Fixed a bug regarding the use of the QE which doesn't
686 effect the result because the default is used anyhow.
687 (The bug was there since 14/07/2005)
688
689 - callisto: Changed the default for fgLoGainStartShift to -2.4
690
691 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
692 factors to be always 10 for all pixels as soon as the first
693 calibration update has happend.
694
695 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
696 was off by more than one slice (which gives wrong values for
697 pixels which have saturated the hi-gain) This was a problem
698 mainly for timing studies, not so much for the automatic standard
699 analysis. Also the values for the Spline have been changed slightly:
700 + Digital Filter from 1.70 to 0.95
701 + Spline from 1.39 to 1.30
702 The numbers were sorted out by an extensive test in the
703 test-database.
704
705 - callisto: Removed the tab showing the average calibrated arrival
706 time. It never gave useful information.
707
708 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
709 lo-gain pulse for data pulses if hi- and lo-gain have saturated
710 and both were extracted because the hi-gain was above the
711 LoGainSwitch.
712
713 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
714 lo-gain pulse position (after application of LoGainOffset, which
715 means in the ideal case it is 0) for data pulses if hi- and lo-gain
716 have saturated and both were extracted because the hi-gain was above
717 the LoGainSwitch.
718
719 - callisto: After extensive tests a new threshold level for determination
720 of the pulse position has been found at 50phe. This is due to the
721 fact that for lower pulses the arrival time changes its average
722 behaviour dramatically. It tends to the average of the extraction
723 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
724
725 - callisto: Added two more plots to the calibration part. The average
726 extracted signal and the average extracted arrival time as
727 extracted by the signal extractor (This can help debugging problems
728 because it doesn't involve a fit)
729
730 - star: changed the fit for the effective on time such that initial
731 values are calculated automatically now instead of using build
732 in values. This makes the fit more indepedant of the underlaying
733 rates. With a test of ~350 sequences in the test database it could
734 be shown that the new fit gives the same result +/-1sek.
735 The highest deviation was +5s the lowest -10s. You can now control
736 the bahaviour with two resource values:
737 MHEffectiveOnTime.FistBin: 3
738 MHEffectiveOnTime.NumEvents: 12000
739 Use FirstBin=1 and NumEvents=120 to fit the effective on time
740 from the resulting gamma candidates
741
742 - star: The Center histogram in MHHillas is now by default displayed
743 with the colz draw-option
744
745 - ganymed: now produces valid error codes if failed
746
747 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
748 with the option "hadronness" instead of "area" or "both" if
749 you want to use both cuts. The hadronness cut includes a fixed
750 cut in hadronness (index 8) and a fixed cut in size (index 9).
751
752 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
753 the M3Long of the anti source to be not properly evaluated
754 (actually is was evaluated as a unique random number) in case
755 of optimization with anti-theta cut switched on. This might have
756 lead to improper, but not necessarily wrong, optimization results.
757
758 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
759 how to use random forest
760
761 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
762 ganymed_onoff.rc. Seems to be unintentional that they were different.
763
764 - sponde: Since the introduction of the possibility to define a
765 normalization energy instead of using the integral the default
766 was not using the integral anymore but a normalization energy of
767 1GeV. It is now the integral again.
768
769 - sponde: Fixed a problem in the weighting which did not allow
770 a MC slope of -1.
771
772
773
774 *** Version 0.9.6 (2006/05/24)
775
776 - general: changed the binning of the azimuthal profile of the camera
777 such that it is aligned with the 60deg boundaries.
778
779 - merpp: better handling of problems with the TH, TD part of the
780 CC-REPORT for files older than 200507190 and 200412210
781 respectively
782
783 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
784
785 - merpp: implementd latest changes in starguider reports (sinc 9th May)
786
787 - callisto: if an arrival time is extracted outside the fadc range is
788 was set to the boundary before. Now a random number is assigned
789 instead to avoid unfortunate coincidences of arrival times just
790 by this arbitrary value.
791
792 - callisto: added a new option to callisto.rc which allows
793 to set the maximum arrival time difference allowed for the
794 badpixel algorithm to determin whether a pixels belongs to a shower:
795 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
796
797 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
798 to 0.9 as suggested by Stefan due to a recent study on the fraction
799 of pixels surviving the image cleaning
800
801 - callisto: switched off error in case of "pulse is too much to the left"
802
803 - callisto: The extraction window is not adapted anymore. This means that
804 the pulse is extracted from the full range. The draw-back is that the
805 background (pedestal) will become slightly higher. Switching on/off
806 the PulsePosCheck in the callisto.rc only effects filling the
807 histograms.
808 WARNING: If the pulse is too much to the left data is calibrated!
809 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
810 in the database to make sure that your data is valid!
811
812 - star: Show also the number of stars correlated correctly by the
813 starguider
814
815 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
816 than one off-source region in wobble-mode. To use it add the following to
817 your ganymed_wobble.rc:
818 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
819 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
820 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
821 + Cut1.ThetaCut: None
822 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
823
824 - ganymed: in the case the latest report is older than a default (currently
825 one minute) and the current report will be skip the starguider
826 correction and calibration will be reset. The maximum age can be
827 setup from ganymed.rc by (minutes):
828 MPointingDevCalc.MaxAge: 1.5
829
830 - ganymed: A first implementation showing all size-bins for the theta-sq
831 resp. alpha-plots in a single tab automatically
832
833
834
835 *** Version 0.9.5.1 (2006/05/05)
836
837 - general: Added a new option "zdiff" to the Makefile which runs
838 "cvs diff" as "make diff" would do, but with compression
839
840 - general: accelerated MTFillMatrix (used for eample in all training
841 and optimization macros) by skipping some obsolete calles in the
842 eventloop the first and second loop could be accelerated by ~20%
843
844 - general: Added a missing feature in the MFilterList class which
845 prevented MFEnergySlope from working correctly in trainenergy.C
846
847 - general: Accelerated the random forest training and usage a bit
848
849 - merpp: Adapted to new raw data file format version 6
850
851 - merpp: fixed a problem with reading the starguider reports
852 after 6.3.2006
853
854 - callisto: At some times six pixels had to be exchanged manually in the
855 data. If the pixels to be swaped are both not found, an error was raised
856 and calibration was stopped. Now it is assumed they are intentially not
857 mapped and the Error has been changed to a Warning.
858
859 - star: Added new image cleaning based on the arrival time of the shower.
860 The new cleaning can be accessed using the parameter "Time" instead of
861 the the old one (like "Absolute) in the star.rc-file.
862 Recommended parameters:
863 + MImgCleanStd.CleanLevel1: 8.2
864 + MImgCleanStd.CleanLevel2: 5
865 + MImgCleanStd.CleanRings: 2
866 + MImgCleanStd.KeepSinglePixels: No
867
868 - star: Simplified the calculation of the effective on time. By letting
869 the fit start in the third bin the result should become more stable.
870 The fit quality is now ignored for the theta-plot which is not used
871 in the analysis later. Still better pre-cut which, for example,
872 remove events triggered by car-light (rate changing on a short
873 time-scale) are missing.
874
875 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
876 for optimization (kWeakSource) which is suggested by the Berlin
877 people for weak sources.
878
879 - macros: plotdb.C:
880 + if no dataset and no time-interval is given only sequences with
881 an effective on-time above five minutes are plotted anymore
882 + added a new tab "RelTime" displaying the relative on-time
883 (effective on-time divided by the observation time)
884
885 - macros: optim*.C: by skipping some obsolete calles in the eventloop
886 the optimization became a lot faster
887
888 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
889 To display them just delete the pads displayed on top.
890
891 - ganymed: fixed a bug which could cause strange behaviour in wobble
892 mode if no starguider information was available due to an incorrect
893 initialization of the starguider calibration
894
895 - ganymed: The scale region in the False Source Plot (MHDisp) can now
896 be changed from within the plot. It can also be setup from the
897 resource file using:
898 + MHDisp.fScaleMin: 0.325
899 + MHDisp.fScaleMax: 0.475
900
901 - ganymed, showplot: Fixed a problem with the fit to the off-data
902 (HistOff) which could cause a time lag or an inifinite loop.
903 The bug did not effect the results at all.
904
905 - sponde: Added a new tab showing the effective collection area after
906 trigger (including the software trigger)
907
908 - sponde: MMcSpectrumWeight has a new option which allows to define
909 the scaling factor not by the integral of the events but at
910 a defined energy:
911 e.g. MMcSpectrumWeight.NormEnergy: 200
912
913 - MTFillMatrix, sponde: by skipping some obsolete calles in the
914 eventloops the loop could be accelerated by ~20%
915
916
917
918 *** Version 0.9.5 (2006/03/13)
919
920 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
921 and added the standard Disp-parametrization
922
923 - macros: added a new macro datacenter/macros/plotstat.C allowing
924 to plot statistics about the data processing
925
926 - macros: added a new macro to plot the muon correction coefficients
927 versus period (macros/plot/mucal.C)
928
929 - showplot: path inflation for ganymed files was broken
930
931 - callisto: Fixed an important bug. When the number of saturating pixels
932 were calculated the bad pixel information already available from the
933 calibration was ignored. This yields wrong values in case pixels
934 are broken and saturate all the time or randomly.
935
936 - callisto: Updated Muon calibration constants. Spline data now also uses
937 different values for different periods
938
939 - star: The time-evolution shown in the effective on-time plot now displays
940 the axis range (if there are no holes it should be similar to the
941 effective on-time)
942
943 - star: Added two new image parameters:
944 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
945 the three pixels next to the center of gravity and the size
946 + MNewImagePar.fConcCore: The ratio of the signals of all
947 pixels inside or touching the ellipse and the size
948
949 - ganymed: now stops in requested source isn't found in catalog file
950
951 - ganymed: Many improvements to the phi-plot in wobble mode:
952 + with a template the ideal background is displayed
953 + a possible camera inhomogeneity is taken into account
954 + the anti theta cut is better supported
955 + the phi cut is automatically calculated from the theta cut
956 See the examples in ganymed_wobble.rc for more details.
957
958 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
959 times the bin-width instead of the absolute energy
960
961 - ganymed: New cuts for on/off and wobble mode
962
963 - ganymed: The smearing of the False Source plot has been increased
964 to 0.06
965
966 - ganymed: The starguider calibration can now be changed from the
967 resource file.
968 See the examples in ganymed*.rc for more details.
969
970 - ganymed: added a new option for on-/off-observations
971 MJCut.RandomSourcePosition
972 If switched on the distribution of observation time of the source
973 position in the camera is calculated from the on-data and randomly
974 applied with this distrbution to the off-data.
975
976 - ganymed: by skipping some obsolete calles in the eventloop the
977 first and second loop could be accelerated by ~20%
978
979 - ganymed: The default in ganymed_onoff.rc is now to determin the source
980 position in the off-data randomly according to its distribution in the
981 on-data.
982
983
984
985 *** Version 0.9.4.3 (2006/02/13)
986
987 - general: Fixed a bug in most of the programs which prevented the
988 compile date in the startup message to be displayed
989
990 - general: Simplified program calls. The following abbreviations
991 are now possible:
992 showlog callisto 55599
993 showplot signal 55599
994 star 55599
995 callisto 55999
996 ganymed 2
997 In this cases the corrsponding root-, log-, sequence- or dataset-
998 filename is automatically compiled using the default datacenter
999 paths ("/magic/*")
1000
1001 - general: Fixed a long outstanding bug which made axis tick marks
1002 disappear if MDataFormula was used (eg. abs(x))
1003
1004 - general: Updated MMath with new functions to calculate the results of
1005 a exponential, logarithmic and powerlaw fits analytically.
1006
1007 - general: Updated some macros with comments:
1008 + macros/optim/optimdisp.C
1009 + macros/optim/optimenergy.C
1010 + macros/optim/optimwobble.C:
1011
1012 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1013 files) now allows adding a pre-cut like in the optimization. E.g. this
1014 is useful to perform g/h-separation cuts before training the random
1015 forest.
1016
1017 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1018 correctly assigned in the raw data assignement table. A fix to correct
1019 the assignment tabel have been implemented.
1020
1021 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1022 by 90, 180 and 270 deg.
1023
1024 - general: the macro plotdb.C now allows to highlight sequences belonging
1025 to a datset. For more details see the descritions in the macro.
1026
1027 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1028 of the display, it gave wrong results espacially for big sizes.
1029 Now the embedded canvas should always have a ratio width/height=3/2.
1030 The "Size" options have been updated with values fitting the 3/2
1031 size ratio.
1032
1033 - RanForest:
1034 + Updated the random forest classes to support also the
1035 regression method implemented by Thomas H.
1036 + added new tutorial macro how to train the random forest
1037 for energy estimation (macros/optim/rfenergyest.C)
1038 + new classes to train the random forest (still in development)
1039 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1040 + new tutorial macros for random forest training in macros/train
1041 trainenergy.C, traindisp.C, trainseparation.C
1042
1043 - mars: now allows to setup a cut in the resource file mars.rc to choose
1044 the events to be displayed, eg:
1045 Cut.Condition: {0} && {1}
1046 Cut.0: MHillas.fSize>100
1047 Cut.1: MHillas.fSize<900
1048
1049 - merpp: Made aware of the new .rep format 200510250. This includes
1050 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1051 the discriminator thresholds (MCameraTD) and the disciminator
1052 delays (MCameraTD). All of them come with the CC report and are therefor
1053 written to the CC tree.
1054
1055 - callisto: fixed a bug in the calculation of the arrival times in
1056 the Digital Filter. They were all shifted by the same amount
1057 fHiGainFirst. This caused an offset in the order of the position of
1058 the left border of the extraction window in the times calculated
1059 from high-gain and from low-gain. The bug effected only the absolute
1060 arrival times. The bug was there since 30.1.2005.
1061
1062 - callisto: Changed the ExtractionWindow for the pulse position check
1063 such that the camera inhomogeneity becomes as less as possible and
1064 comparable to the pulso position check switched off. More details
1065 on the study will be given at our result web-page.
1066
1067 - ganymed: ganymed.rc, ganymed_onoff.rc:
1068 changed to new cuts trained with 1ES1218 and Crab-data
1069 for maximum sigma*log10(excess)
1070
1071 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1072 a new option was implemented to estimate Disp (CalcDisp)
1073
1074 - ganymed: Implemented two new options which allow
1075 to overwrite the default path to search for the sequence files
1076 --ins=/magic/sequences
1077 and where to search for the image data
1078 --ind=/magic/data/star
1079
1080 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1081 dx/dy from the resource file by
1082 MSrcPosCorrect.Dx
1083 MSrcPosCorrect.Dy
1084
1085 - ganymed: fixed reading the source catalog. Only as many chars
1086 as the requested source name had were compared (If a source
1087 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1088 were requested it could happen that the coordinates of
1089 "1ES1218" were read) The source coordinates are now printed
1090 in addition to its name to the logging output.
1091
1092 - ganymed: changed the background fit in the case of a ThetaSq function
1093 from a polynomial to a exponential, this should give a big improvement
1094 for on-only analysis'
1095
1096 - ganymed/sponde: Calculation of the error of single size-/energy-
1097 bins now uses Li/Ma (5) instead of LiMa (17)
1098
1099 - sponde: Added a plot E^2*dN/dE
1100
1101 - sponde: The energy estimator plot should now show values like
1102 they are commonly used.
1103
1104 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1105 (a powerlaw with cutoff didn't work before)
1106
1107
1108
1109 *** Version 0.9.4.2 (2005/10/01)
1110
1111 - general: added new tutorial macro macros/tutorials/threshold.C:
1112 how to calculate the threshold
1113
1114 - general: added a new game. Start it from the interpreter with
1115 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1116 and MagicReversi)
1117
1118 - general: neighbor pixels in MGeoms are now sorted clockwise
1119
1120 - merpp: made aware of new format 20050829-0
1121
1122 - callisto: New scale factors from muon analysis, stored in new
1123 resource file resources/calibration.rc
1124
1125 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1126 the eventloop if something went wrong. This is necessary for the
1127 automatic processing
1128
1129 - callisto: Implemented a new treatment for the time information
1130 developed by S.Ruegamer, this should give much better response than
1131 the old very primitive algorithm. This is especially important
1132 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1133 treatment was buggy! As neighbor pixels to interpolate the
1134 arrival times always the pixels 0 to 5 were taken)
1135
1136 - callisto: In addition to the new treatment of arrival times the
1137 decision of the treatment whether a pixel contains shower
1138 information or not is used to improve the signal interpolation
1139 further. Previously interpolated pixels showed a non-zero signal
1140 do the peak searching signal extractors. Having a signal pixel
1141 beside raised the signal above the cleaning level. Thus the
1142 pixel survived cleaning to often but with a too low mean signal.
1143 By replacing empty pixels with a gaus (mean and rms from the
1144 corresponding Area entries in MPedPhotCam) this effect can
1145 be supressed.
1146
1147 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1148 got lost when the events were stored by the calibration... fixed.
1149 (This was no problem for normal image cleaning because the pixel
1150 content was artificially set to 0 not surviving standard cleaning
1151 algorithm)
1152
1153 - callisto: Fixed a bug which caused the random and peak-search pedestal
1154 extracted with an extractor to be exchanged for the first (roughly)
1155 500 events (*Extractor and *ExtractorRndm).
1156 (They were simply exchanged in callisto.cc) This bug might have been
1157 introduced in Mars 0.9.4 when the order of calculation of the two
1158 types of pedestal in callisto got exchanged. The bug only effects
1159 the first seconds of data of each sequence.
1160
1161 - star: Taking the arrival time of Muons into account the calculation
1162 of the parameters could be made independant of the noise
1163 (pedestal rms). The dependance was due to the bias of the peak search
1164 extractor. Now only a ZA dependamcy is left which is not yet fully
1165 understood.
1166
1167 - ganymed: The sequences were still not sorted correctly in any case,
1168 because they were sorted by the full qualified path name. Now they
1169 are sorted by their sequence number.
1170
1171 - ganymed: new values for the spark-event-cut
1172
1173 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1174
1175
1176
1177 *** Version 0.9.4.1 (2005/08/18)
1178
1179 - callisto: fixed some problems with the calibration in case of
1180 inteleaved events. Therefor the final and some intermediate
1181 fits are skipped which would take place on partly filled #
1182 histograms and gave wrong results or failed completely.
1183
1184 - callisto: If the intermediate finalization of the histograms
1185 calculating the mean charge of the calibration signal fails
1186 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1187
1188 - ganymed: Fixed some bugs which caused problems in On-only mode.
1189 Still the false source plot doesn't give reasonable results.
1190
1191
1192
1193 *** Version 0.9.4 (2005/08/05)
1194
1195 - general: Fixed the ZA binning. It did not correctly fit the
1196 MC binning
1197
1198 - general: Added a class to correct for the missfocussing in
1199 April (MSrcPosCorrect)
1200
1201 - general: Random Forest energy estimator should now work properly
1202
1203 - general: MHCamera now displays the profiles in deg instead of mm
1204
1205 - general: MH::SetPalette offers a lot of new palettes
1206
1207 - general: MHillas - the case of CorrXY==0 is now handled properly
1208
1209 - general: implemented the possibility to change the line and
1210 marker style of a sky-grid drawn by MAstroCatalog
1211
1212 - general: Runs in sequences and datasets are now automatically
1213 ordered (it is assumed that the order of their filenames correctly
1214 represents the order of observations) to ensure correct reading
1215 of the subsystem data
1216
1217 - general: Runs cannot be added to a sequence twice anymore. Also
1218 Sequences cannot be added twice anymore to a dataset.
1219
1220 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1221 It gave wrong results by 1./2pi
1222
1223 - showplot: got a new option to start a root interpreter, too
1224
1225 - mars: now displays a rough estimate of Disp and the third moment
1226
1227 - mars: now displays the event time MTime if available
1228
1229 - mars: show muon parameters graphically
1230
1231 - mars: now the file to open can be given as commandline
1232 argument
1233
1234 - merpp: Added support for new arehucas version >= 200507190
1235 implementing values for three temperature sensors in the
1236 counting house (MCameraAUX) and the name of the HV settings file
1237 (MCameraHV).
1238
1239 - merrp: Also fixed some problems with wrong versions numbers stated
1240 by arehucas and implemented some fixed for old versions (<200407070)
1241
1242 - callisto: MCalibrationHiLoCam can now be printed from its context
1243 menu, eg in the TBrowser
1244
1245 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1246 - 1.39 (MExtractTimeAndChargeSpline)
1247 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1248 This is important mainly for timing studies.
1249
1250 - callisto: Changed limits in MHCalibrationChargeCalc from
1251 - -100.125 to -98 (fgChargeHiGainFirst)
1252 - 1899.875 to 1902. (fgChargeHiGainLast)
1253 - -100.25 to -99 (fgChargeLoGainFirst)
1254 - 899.75 to 901. (fgChargeLoGainLast)
1255 Introduced new limits:
1256 - fgNumLoGainBlackoutLimit: 0.05
1257 - fgLoGainBlackoutLimit: 3.5
1258 - fgLoGainPickupLimit: 3.5
1259
1260 - callisto: The handling of automatic weights for the digital filter
1261 has been improved. There are now new calibration weights special
1262 for Monte Carlo calibrations.
1263
1264 - callisto: Updated Muon scale with latest results (1% difference
1265 for most data, 5% for Mar/Apr'05)
1266
1267 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1268 was saturated and the blackout-events in the low-gain exceed the
1269 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1270 This excludes those pixels which have a saturating high-gain
1271 channel, but the low-gain switch does not switch often enough
1272 to make the distribution reliable.
1273
1274 - callisto: fix a bug counting the number of saturated events. Up to now,
1275 the number of saturated slices was counted (which is one for a not too
1276 high number), but for some (pathological) pixels, many more slices
1277 saturated and produced wrong limits.
1278
1279 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1280 + MCalibrationRelTimeCam.CheckFitResults: Yes
1281 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1282 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1283 + MCalibrationRelTimeCam.CheckOscillations: Yes
1284
1285 - callisto: introduce max. number of events for intercalibration,
1286 the rest gets skipped. Default: 4096
1287 The calibration causes too many un-reliable pixels if more
1288 than about 5000 events are treated (@500 Hz) because of the
1289 mode hopping of the VCSels. However, in the past, some
1290 calibration runs have been taken (erroneously) with more
1291 than 5000 events, especially the intensity scans where
1292 a good precision is needed.
1293
1294 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1295 photo-electrons for the spline extractor by 1-2% (correctly).
1296
1297 - callisto: The intercalibration is now done using a full f-factor
1298 method instead of a simple update. This makes things slower but
1299 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1300 changes.
1301
1302 - callisto: MPedestalY3 now uses the same extraction range as the data
1303 as calculated by MPedestalY2
1304
1305 - callisto: A check of the fraction of allowed unsuitable (10%) and
1306 unreliable (30%) pixels has been addded when the conversion is
1307 calculated from interleaved events
1308
1309 - star: fixed a bug which caused MEffectiveOnTime containers not to
1310 be written. In the worst case they were skipped almost all, in the
1311 best case they were all ok. It depends on how often the new value
1312 was assigned just with an event which was skipped later by another
1313 task
1314
1315 - star: new histograms MHPointing and MHRate
1316
1317 - star: New tab (Currents) displaying the time evolution of the mean
1318 DC currents
1319
1320 - star: New tab (MeanRms) displaying the time volution of the mean
1321 Pedestal Rms
1322
1323 - star: Output now contains MReportStarguider
1324
1325 - star: Improved muon analysis. Due to the absense of a constant
1326 for the gaus fit for arc width and the fact that the arcwidth
1327 plot was a histogram instead of a profile the resulting psf
1328 became pedestal rms dependant
1329
1330 - ganymed: added new plot (MHPhi) for wobble mode as described in
1331 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1332
1333 - ganymed: corrects now (correctly?) for the misspointing in
1334 May/April 05
1335
1336 - ganymed: Two new default templates for ganymed.rc are avilable:
1337 ganymed_onoff.rc and ganymed_wobble.rc
1338
1339 - ganymed: The first version of MFMagicCuts has been released
1340
1341 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1342
1343 - ganymed, sponde: There are two new options to determin the number
1344 of bins for the signal region (NumBinsSignal) and the number of
1345 total bins (NumBinsTotal) in the MHThetaSq histogram
1346
1347 - ganymed: optimized palettes for MHDisp
1348
1349 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1350 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1351 sqrt(2) to large
1352
1353 - ganymed: The false source plot (MHDisp) is now based on Disp
1354 and a background model determined in the first loop is
1355 subtracted
1356
1357 - ganymed: MFMagicCuts are now available in the cvs. The correct
1358 solution for the disp ambiguity problem is now calculated using
1359 the third moment. The third moment cut therefor is skipped.
1360
1361 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1362 already determined by the third moment along the major axis and
1363 so its actual sign is aligned along the major axis of the shower.
1364
1365 - ganymed: If starguider data is available it is taken into account
1366 when calculating the source position. This is especially important
1367 for wobble data at high zenith angles and culmination data.
1368
1369 - ganymed: If available the starguider data is taken into account as
1370 good as it is possible without a starguider calibration. To switch
1371 it off add
1372 MPointingDevCalc.MaxAbsDev: -1
1373 to your ganymed.rc
1374
1375 - sponde: the zenith angle distribution is now weighted instead of
1376 choosen by default. This gurantees higher statistics in the highest
1377 and lowest energy bins. To switch this behaviour off use...
1378
1379 - sponde: now automatically displays the energy threshold
1380
1381
1382
1383 *** Version 0.9.3 (2005/06/03)
1384
1385 - general: MMcEvt now derived from MMcEvtBasic which should
1386 have no influence on compatibility with older camera files
1387
1388 - general: Implemented a new option to MReadReports which allows
1389 to force reading of the first event of some trees (eg. Drive-tree)
1390 before any other tree.
1391
1392 - general: Made a fix to MPointingPosCalc which assumes that the
1393 run-type is real-data if Process is called before ReInit, such
1394 that also the very first Drive-events in a run are treated
1395 correctly.
1396
1397 - shoplot now displays the filename in the title bar of the window
1398
1399 - merpp: new options: --auto-time-start --auto-time-stop which
1400 allow to cut updating with slow-control at the start- or
1401 (previousle --auto-time only allowed: and) stop-time of
1402 the run stored in the runheader.
1403
1404 - callisto: changed default of fgFallTimeHiGain in
1405 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1406 already set as default in callisto_Dec04Jan05.rc
1407
1408 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1409 now changes the filename for new weights automatically for
1410 cosmics, MC and for different calibration colors.
1411
1412 - callisto: a problem with the order of some code cause the
1413 name of the weights file in MPedestalY2 to be ignored.
1414 Wrongly the calibration_UV weights were used instead
1415 of the cosmics weights set in callisto.rc.
1416
1417 - callisto: should allow ct1 pulser data when the color is
1418 explicitly set also for pretty new runs
1419
1420 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1421 to introduce an additional scale factor (should be around 1)
1422 to adapt for slight deviations in different extractors from
1423 the MC calibration. For MC calibrations the scale factor
1424 is fixed to 1
1425
1426 - callisto: MFCosmics should handle very high signals a bit
1427 more accurate now
1428
1429 - callisto: when calculating the mean pedestal rms for different
1430 pixel sizes or sectors also kUnsuitableEvt is now taken into
1431 account - not only kUnsuitableRun
1432
1433 - callisto: '-raw' option is now the default
1434
1435 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1436 This has the advantage that mean values in the calibration (eg
1437 arrival times) are calculated more accuratly.
1438
1439 - callisto: In the resource file callisto_Dec04Jan05.rc
1440 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1441
1442 - callisto: new Hi-/Lo-Gain intercalibration constants
1443 hilocalib_sp1.root and hilocalib_sp1_mc.root
1444
1445 - callisto: changed default for MJPedestalY2.MaxEvents
1446 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1447
1448 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1449 has changed from 9.0 to 6.0. This is necessary to exclude two very
1450 ringing pixels in September which - when kept - destroy the image
1451 cleaning around them (Markus G.)
1452
1453 - callisto: (!) The Muon analysis of all data taken so far has
1454 suggested that different extractors give slightly different
1455 absolute results after calibration, due to there different
1456 handling of the calibration- and cosmics pulse shape. Although
1457 the over all calibration seems to be a bit to pesimistic (or
1458 the MC seems to be a little bit - 3-5% - too much attenuated).
1459 There for correction factors have been introduced which correct
1460 the calibration constants by
1461 0.956937799 for Digital Filter (callisto.rc)
1462 and
1463 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1464 calibration. The main advantage is, that both data types can
1465 be easily analysed together and compared to the same MC sample.
1466 The factors are choosen such, that the reference is now a
1467 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1468
1469 - star: fixed a bug which caused the first bin of the histograms
1470 vs time to disapear in PostProcess. This gave wrong results
1471 on the screen. The output and all following programs not
1472 directly accessing the histograms haven't been affected
1473
1474 - star, ganymed: Made sure that always the first Drive-tree event
1475 is read and Processed before the first data event was read.
1476
1477 - ganymed: implemented the possibility to replace the standard
1478 false source plot with a different one. For example: If
1479 you want to use a Disp based FS plot use the resource:
1480 NameHistFS: MHDisp
1481 For details about the requirements of these plots look
1482 at the corresponding classes
1483
1484 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1485 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1486 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1487 case MAlphaFitter is setup correctly. For On-Only optimization
1488 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1489 RunOn() instead of Run(). For energy estimation MJOptimize
1490 has been replaced by MJOptimizeEnergy
1491
1492 - sponde: The input MC spectrum can now be weighted to fake a
1493 different spectrum. This is done via MMcSpectrumWeight. For
1494 more details see the class description and sponde.rc
1495
1496 - sponde: The paremeter comparsion plots are not scaled by
1497 their entries anymore. Instead the MC plot is scaled by using
1498 the result spectrum of the analysis. If the input MC spectrum
1499 and the result spectrum has different slopes the absolut
1500 normalization is normally wrong.
1501
1502
1503
1504 *** Version 0.9.2 (2005/05/20)
1505
1506 - general: Changed the default paths for calibrated data and image
1507 files. (The implemented access to these files doesn't yet exist)
1508
1509 - general: support for MRunIter has been removed from the job classes
1510 (use the setter functions of MSeqeunce instead)
1511
1512 - general: ProcessFile has been renamed to Process in all job classes,
1513 because ProcessFile is missleading
1514
1515 - general: The storage of the palette in MHCamera is now possible
1516
1517 - general: new bits describing unsuitable and unreliable pixels have
1518 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1519 kDeadPedestalRms, kFluctuatingArrivalTimes
1520
1521 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1522 versions newer than V200404070
1523
1524 - general: support for cc file versions newer than V200504130. Added
1525 support for active loads (MCameraActiveLoad) and central pixel
1526 (MCameraCentralPixel)
1527
1528 - general: added new histograms for image parameters versus size
1529 (MHVsSize)
1530
1531 - general: The eventloop now automatically calls PrintStatistics
1532
1533 - Status Display: Improved support for printing:
1534 + A default can now be set in .rootrc (for more details see
1535 MStatusDisplay::PrintPS)
1536 + A print dialog is opened so that printer and command line
1537 can be canged
1538
1539 - showlog: improved such that it handles different verbosity levels
1540 more accurate now. This mean you can suppress output when
1541 using showlog.
1542
1543 - showplot: improved
1544 + The new graphics formats have been implemented
1545 (pdf, svg, png, jpg and xpm)
1546 + Implemented an interface for printing. Because you can change
1547 the printing command from the command line you can use all
1548 the nice postscript tool. To print a booklet for example call:
1549 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1550 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1551 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1552
1553 - callisto: fixed a bug in the recognition of the calibration bit
1554 pattern. Concerns only intensity calibration. (The strength of the
1555 intensity has been updated in some cases)
1556
1557 - callisto: add a filter against PIN Diode events when running over
1558 calibration runs since some of the recent calibration runs have
1559 been taken with Pin Diode.
1560
1561 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1562 39943, 44833 in the calibration (MCalibColorSet)
1563
1564 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1565 been set to 1e-18 in callisto_Dec04_Jan05.rc
1566
1567 - callisto: in callisto_Dec04Jan05.rc: set value for
1568 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1569 statistics for the calculation of the mean pulse time
1570 of the cosmisc
1571
1572 - callisto: the charge limit in the calibration has been raised
1573 from 2.5 to 4.5
1574
1575 - callisto: new setup read from callisto.rc
1576 + MCalibCalcFromPast.fNumEventsDump
1577 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1578 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1579
1580 - callisto: MExtractTimeAndChargeSpline extractor:
1581 + The integration ranges were shifted by 0.2 FADC slices to the right.
1582 + unreliable handling of floating point values caused different
1583 results on different platform or with different compiler options:
1584 The new algorithm is numerically exact and more accurate because
1585 it doesn't calculate the integration position by multiple times
1586 adding the step-size (which results in numerical uncertanties
1587 exspecially if multiplied with large numbers)
1588 + A lot of fixes have been introduced which effects integrating the
1589 spline at the edges of the valid range. In this case any memory
1590 was randomly accessed. This behaviour can be tested replacing
1591 all MArrayF by TArrayF which perform a range check (but of course
1592 they are a lot slower)
1593 ! No result obtained with the Spline before can be trusted! Due to
1594 random memory access it might by completely random!
1595
1596 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1597 + extraction range in the high gain to 4.
1598 + weights file to cosmics_weights46.dat
1599
1600 - callisto:
1601 + introduce the check for fluctuating arrival times.
1602 + set charge limit to from 2.5 to 4.5
1603 + introduce asymmetric exclusion due to "deviating number of phes":
1604 Default: -9.0 +4.5
1605 + make deviating number of phes unsuitable (see David's findings).
1606
1607 - callisto: fixed the display of unsuitable pixels. The old change
1608 to a real profile in MHCamera broke it.
1609
1610 - callisto: The cosmics filter is used in MJCalibration now
1611 independant of the pulser color (formaly it was used only for
1612 CT1-pulser data). The threshold of number of max empty pixels
1613 has been raised from 2% to 5% in MJCalibration. The maximum
1614 fraction of rejected event is 50% otherwise the calibration has
1615 failed. The filter now ignores unsuitable pixels.
1616 Setup the filter from callisto.rc using "ContCosmics"
1617 (see MFCosmics::ReadEnv)
1618
1619 - callisto: changed default for fgOffsetFromLogain back
1620 from -2.8 to -1.8 in digital filter.
1621
1622 - callisto: for the common extractors
1623 + MExtractFixedWindow
1624 * MExtractTimeAndChargeSlidingWindow
1625 * MExtractTimeAndChargeSpline
1626 * MExtractTimeAndChargeDigitalFilter
1627 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1628 and fResolutionPerPheLoGain
1629
1630 - callisto: Updated the hi-/lo-gain intercalibration constants
1631 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1632 hilocalib_df6.root
1633
1634 - callisto: The default lo-gain extraction window for the
1635 MExtractTimeAndChargeSlidingWindow extractor has been increased
1636 from 6 to 8 to take the stretch of the pusle into account
1637
1638 - callisto (!!!): fixed an important bug in the setting of the
1639 incoming pedestal pointer to the signal extractor extracting
1640 pedestals. This bug caused the pedestals not to be subtracted
1641 correctly in the calibration afterwards. The effect was about 10%
1642 too high conversion factors for the digital filter and the spline
1643 and more than 40% for the sliding window.
1644 The bug existed since end of February! (Markus G.)
1645
1646 - star: added muon support to star. A new tab "MHMuonPar" is
1647 displayed. The lower right plot is an estimate of the point spread
1648 function. A reference value is displayed. To get the real PSF
1649 you must compare with MC. The setup for the muon analysis
1650 is done in star.rc. More informations can be found in
1651 MHSingleMuon and MHCalibParCalc
1652
1653 - star: The weather data is now displayed in star
1654
1655 - star: MEventRateCalc handles the calculation of the event rate more
1656 accurate now in case of the start of a new run inside a sequence
1657
1658 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1659 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1660 changed only minimally
1661
1662 - ganymed: (MJCut and MJOptimize) now displayes the number of
1663 excess events versus size. The energy estimation is done in
1664 MJSpectrum (sponde)
1665
1666 - ganymed: got support for using other variables than Alpha, eg. Theta.
1667 Therefor you need a class deriving from MHAlpha which supports
1668 this variable (one is already existing: MHTheta, which is now the
1669 default in ganymed). It is setup through ganymed.rc
1670
1671 - added a full featured spectrum program (sponde) which reads
1672 ganymed output and monte carlos and compiles a spectrum
1673
1674
1675
1676 *** Version 0.9.1 (2005/04/14)
1677
1678 - Fix bug on the arrival time reconstruction when using Digital
1679 Filter (in some marginal cases (10%) times were reconstructed shifted
1680 by 0.2 slices)
1681
1682 - all executables now return 2 where in previous versions -1 has
1683 been returned (gave problems with shell-scripts)
1684
1685 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1686 also done with a intercalibration input file
1687
1688 - a bug in the time fine adjustment of the digital filter has been fixed
1689
1690 - a lot of small fixes to calling TPad::Divide with a margin==0
1691
1692 - MStatusDisplay now shows the memory usage
1693
1694 - added a memory leak statistic after the eventloop
1695
1696 - MHadronness replaced by MParameterD
1697
1698 - MEnergyEst replaced by MParameterD
1699
1700 - wobble mode can now be switched on from the data-set
1701
1702 - switched on bad pixel detection for a pedestal level
1703 which is more than 5 times the variance
1704
1705 - Fixed default paths to be correct for the new data center
1706
1707 - Fixed handling of drive data. The pointing position in now
1708 copied to MPointingPos inside star for real and MC events
1709
1710 - made sure, that the sequences in a dataset are sorted by
1711 their number to ensure the correct synchronization
1712
1713 - added all resource files necessary to handle spline extraction
1714 of signal for the late 2004 and the early 2005 data
1715
1716 - update the reference lines for the december data
1717
1718 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1719 This is important for the Dec. and Jan. data where the calibration
1720 pulse position changes much.
1721
1722 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1723 filter. This corrects only an defective extraction of the MC at
1724 low-gain signals lower than 90 phes.
1725
1726 - fixed some slowdown in calibrating data with interleaved events from
1727 Jan and Dec. As a workaround made the pretty palette the default.
1728 The inverse Deep Blue Sea has a bug which slows down long calibration
1729 runs a lot.
1730
1731 - implemented new values from new starguider report as defined
1732 in TDAS00-07 V7.1 (eg SkyBrighness)
1733
1734 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1735 in starguider report (If you merpp the same reports with this version
1736 you'll get the correct units (arcmin) but a different result
1737 than with old versions (wrong units))
1738
1739 - Now the status display can also write PNG, JPEG and XPM (other file
1740 formats are still unsupported by root)
1741
1742 - added a lot of scripts and macros in directory datacenter used
1743 for automatic processing
1744
1745
1746
1747 *** Version 0.9 (2005/03/23)
1748
1749 - Calibration is now done autmatically into photo-electrons like
1750 decided by the Collaboration Board
1751
1752 - Reference lines in the display can be read from resource file
1753
1754 - Interlaced calibration events can be handled by callisto
1755
1756 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1757 and applied in callisto.
1758
1759 - class MJCalibTest can be called by callisto
1760
1761 - callisto can now run with three data types: rawdata, rootdata, MC
1762
1763 - added two classes mreport/MReportStarguider.cc and
1764 mreport/MReportStarguider.h for implementing starguider-data
1765
1766 - the output of merpp-update now contains starguider information:
1767 MReportStarguider and MTimeStarguider
1768
1769 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1770 values were lower than they should. This was more visible for high
1771 energy (Size) events.
1772
1773 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1774
1775 - added a new loop to callisto to support the correct extraction of
1776 the pedestal and pedestal rms through the signal extractor
1777
1778 - added class to perform fourier tranformation of a hexagonal structure
1779 (MHexagonalFT)
1780
1781 - added class to perform fourier tranformation of a hexagonal structure
1782 in a tasklist (MHexagonalFTCalc) example: hft.C
1783
1784 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1785 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1786 small pixels, example: extendcam.C
1787
1788 - added possibility to write data to memory (TTree) using MWriteRootFile
1789
1790 - added possibility to read a TTree stored only in memory by MReadTree
1791
1792 - new classes to deal with the interleaved calibration events:
1793 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1794
1795 - implemented filters to callisto to skip calibration events
1796
1797 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1798 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1799 the slices by statistics
1800 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1801 signal extractor without randomization
1802 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1803 with the signal extractor with randomization (extraction window is
1804 randomly fixed)
1805 The three kind of pedestal is not yet implemented (for speed reasons) as
1806 long as nobody really needs it:
1807 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1808 extracted with the signal extractor with randomization
1809
1810 - callisto now finds the pulse position in the data automatically
1811
1812 - implemented data reduction in calibrated data by reducing the precision
1813 of the stored floating point values (pedestal, rms and signal) to
1814 roughly 0.5%
1815
1816 - fixed showplot to make file format conversion (eg. converting a
1817 status display stored in a root file into a postscript file) in
1818 batch mode possible:
1819 showplot -b --save-as-ps[=outfile.ps] infile.root
1820
1821 - Allow class names as part of filter rules, eg
1822 (MFSupercuts) && (MHillas.fSize>100)
1823
1824 - fixed a lot of stuff to allow all programs to process MonteCarlo
1825 camera files.
1826
1827 - enhanced possibility to debug reading of resource file
1828
1829 - MDataChain should handle priorities of operator more
1830 accurate now
1831
1832 - completely revised the container in which the signal is stored
1833 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1834 * the new implementation is faster and
1835 * needs less storage space
1836
1837 - FIRST version which can process Monte Carlos through the
1838 whole chain of programs (callisto, star, etc)
1839
1840 - implemented new image parameters for the border length of
1841 the shower image (MNewImagePar2)
1842
1843 - implemented wobble-mode in ganymed
1844
1845 - new class (MJOptimize) taking care of all optimization processes
1846
1847
1848
1849 *** Version 0.8.6 (2004/10/05)
1850
1851 - New combined signal and time extractor
1852 MExtractTimeAndChargeDigitalFilter
1853
1854 - The Report for the trigger section in the CC run summary has been
1855 updated, and now the IPRs (Individual Pixel Rates) are available.
1856
1857 - new macros for database interaction: filldotrun.C, filldotrbk.C
1858
1859 - added new program which can convert colored output which was redirected
1860 into a file back into colored text (for example to display it with
1861 more): showlog
1862
1863 - added new program to display an MStatusArray of plots (stored with
1864 MStatusDisplay) from a file: showplot
1865
1866 - Added support for Sequences (MSequence). Sequences are blocks of run
1867 files containing the same calibration and belonging to the same
1868 source
1869
1870 - Added a new task (MTaskEnv) which can be used in setup files to switch
1871 between different tasks (for example to choose a signal extractor)
1872
1873 - Implemented automatic file splitting in MWriteRootFile
1874
1875 - After image cleaning an island index is assigned to all used pixels.
1876 The index corresponds to the order of the islands in size.
1877
1878 - added a cleaning which takes signal height _and_ arrival time into
1879 account: probability cleaning (for more details see MImgCleanStd)
1880
1881 - added a cleaning which takes takes the absolute number of photons
1882 times the area ratio as cleaning level
1883 (for more details see MImgCleanStd)
1884
1885 - Changed calculation of image parameters such, that it can be done
1886 for all used pixels or the pixels with a defined island index only
1887
1888 - implemented new image parameters displaying the number of islands,
1889 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1890
1891 - event display in executable changed to support also calibrated files
1892 (done with MJCalibrateSignal)
1893
1894 - added program doing the calibration and the signal extraction
1895 and signal calibration: callisto Most part of the setup is done
1896 by a resource file: callisto.rc
1897
1898 - implemented support for pixels with negative IDs (Raw file format
1899 version 4)
1900
1901 - implemented an new option in merpp (--auto-time) to get the time
1902 range for cc and/or caco data from the run header of the raw data
1903
1904 - New star-program (star and MJStar). Taking calibrated data from
1905 callisto/MJCalibrateSignal as input. The setup is done through
1906 a resource file: star.rc
1907
1908 - Added possibility to setup the eventloop in the mars-executable
1909 Camera Display by a resource file: mars.rc
1910
1911 - The the mars-executable Camera Display can now also read
1912 calibrated data files written by callisto/MJCalibrateSignal
1913
1914 - Added a new class which can calculate the source position in
1915 the camera from a pointing model known to be correct and
1916 the pointing model used for observations (MSrcPosFromModel)
1917
1918 - added a new version of the class calculating the effective on-time
1919 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1920 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1921 MHTimeDiffTheta.
1922
1923 - added the possibility to count how often a signal is above (or
1924 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1925 can replace MHTriggerLvl0)
1926
1927 - added ore convinient ways to set the axis-titles of your histograms
1928 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1929 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1930
1931
1932
1933 *** Version 0.8.5 (2004/08/06)
1934
1935 - new Signal Extractors: MExtractFixedWindowSpline
1936 and MExtractAmplitudeSpline
1937
1938 - implementes interleave in merpp to be able to merpp parts of a file
1939
1940 - implemented force-functionality to merpp
1941
1942 - star display to display star catalogs (MAstroCatalog)
1943
1944 - star display to 'mirror' stars to the camera (MAstroCamera)
1945
1946 - implemented a new cleaning option which allows cleaning scaled with
1947 the real ratio of the rms depending on the pixel size, not only the
1948 square root of the pixelsize (MImgCleanStd, MCameraData)
1949
1950 - removed obsolete MBlind* classes
1951
1952 - Signal extractor taking the AB flag into account implemented (this makes
1953 an odd number of slices for signal extraction possible
1954 (MExtractSignalABcorr)
1955
1956 - implemented a class extracting the pedestal from the raw-data (events)
1957 itself using empty lo-gain (MpedCalcFromLoGain)
1958
1959 - Added mean values to MPedPhotCam
1960
1961 - Added Makefile for Darwin (this OS is NOT officially supported!)
1962
1963
1964
1965 *** Version 0.8.4 (2004/04/19)
1966
1967 - new fast arrival time extractor using cubic splines:
1968 MExtractTimeFastSpline
1969
1970 - implementes multi-argument support in MDataChain
1971 ("pow(a, b)")
1972
1973 - implemented double reference support in MDataChain
1974 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1975
1976 - added support in MF for expressiond like
1977 "MHillas.fWidth<2*<MHillas.fLength"
1978
1979 - MDataChain is now able to support variables like [0], [1], ...
1980 which can be used in fit functions as parameters. The interface
1981 is implemented through the new virtual function
1982 MParContainer::SetVariables
1983
1984 - added new class MArrivalTimeCam/MArrivalTimePix:
1985 Storage containers to hold the ArrivalTime of the camera/pixel
1986
1987 - added new classes for the calibration of relative arrival times:
1988 MCalibrationRelTimePix and MCalibrationRelTimeCam
1989
1990 - added new classes to extract the signal of the blind pixel and the
1991 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1992
1993 - added new classes for the bad-pixels treatment (MBadPixels*)
1994 which are more powerfull than the old ones (MBlindPixel*)
1995 and will replace them.
1996
1997 - added filter against cosmics: MFCosmics
1998
1999 - added new class MArrivalTimeCalc2:
2000 Calculates the arrival time as the signal weighted mean of the time
2001 slices in the maximum window
2002
2003 - added a new macro call pointspreadfucntion.C that fits with a 2D
2004 gaussian the DC spot for an star. It gives you the RMS of
2005 the PSF and the center of the star, very useful for misspointing
2006 studies.
2007
2008 - added support for multi-telescope camera files. Added classes
2009 MStereoCalc and MStereoPar, classes to calculate and store shower
2010 parameters calculated from the data of two telescopes, for the MC
2011 studies regarding the MAGIC clone.
2012
2013 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2014 MC data calibrated in photons instead of ADC counts.
2015
2016 - added three macros to show the calibration and analysis chain of
2017 MC data. The macro starmc.C does both calibration and analysis, producing
2018 an output containing Hillas parameters for each event. The macro
2019 mccalibrate.C does just the calibration and writes out a file containing
2020 pixel information in photons instead of FADC data. The macro starmc2.C
2021 reads in such a file and produces an output with Hillas parameters.
2022
2023 - added MPedPhotCalc to compute pedestals in units of photons, see
2024 macro pedphotcalc.C
2025
2026 - added all class to perform the calibration, see macro calibration.C
2027
2028 - added class MFFT to perform Fast Fourier Transforms
2029
2030 - added class MSimulatedAnnealing to perform simulated annealing
2031 minimizations
2032
2033 - added new macro bootcampstandardanalysis.C which holds the skeleton
2034 of the analysis chain discussed in the december bootcamp.
2035
2036 - added support for DAQ raw data file format V2
2037
2038 - implemented an arbitrary time stamp for the events from raw-data
2039 files with file version<3. It is calculated from the run number,
2040 the date of start and the FADC clock tick from the first module
2041
2042 - implemented the correct decoding of the event time-stamp
2043 coming from the DAQ for raw-data files with file-version>2
2044
2045 - added a new classes storing the pedestals in units of photons:
2046 MPedPhotPix, MPedPhotCam
2047
2048 - added support for DC current files from the camera control
2049
2050 - added support for start- and stop-time when merpping report files
2051
2052 - added MReportCC storing the weather data from the CC-REPORT
2053
2054 - added class to fill trainings and test matrices (MTFillMatrix)
2055
2056 - added a filter performing a software trigger (MFSoftwareTrigger)
2057
2058 - Added classes to perform parts of the standard analysis (Jobs):
2059 + MJPedestals
2060 + MJCalibration
2061 + MJExtractSignal
2062 Note: All of them are preliminary!
2063
2064 - Added Iterator to iterate over files giving only the run-number
2065
2066 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2067 the evolution of a sector vs time
2068
2069
2070
2071 *** Version 0.8.3 (2003/12/05)
2072
2073 - adapted Random Forest classes to allow the use with MC
2074 multi-telescope files which can be produced with the coming
2075 camera version 0.7.
2076
2077 - added classes to read and interprete central control report files
2078 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2079
2080 - enhanced merpp (the executable) to support .raw and .rep files.
2081
2082 - added classes for light calibration (MCalibration* and
2083 MHCalibration*) by Markus Gaug. Further work has to be and will
2084 be done soon.
2085
2086 - Added a preliminary 'synchronizer' (MReadReports) which will
2087 replace MReadMarsFile as soon as it is finished.
2088
2089 - Added a tutorial macro demonstrating how report files are merpped
2090 and how they can be read from the root file in the correct order
2091 of time (readrep.C)
2092
2093 - Added a generalized histogram (similar to MH3) called MVsTime
2094 which allows to plot variables (or rules - MDataChain - of
2095 variables) vs time. For an example have a look at tempvstime.C.
2096
2097 - Changed the name of the event trees:
2098 + Events --> Events
2099 + PedEvents --> Pedestals
2100 + CalEvents --> Calibration
2101
2102 - changed name of MTime in the event trees from MRawEvtTime to MTime
2103
2104 - added displaying the sector indices to the mars event display
2105
2106 - Magic Online Analysis (MOnA) implemented in a first version
2107 (see mona.cc, MOnlineDump and MOnlineDisplay)
2108
2109 - added classes to calculate event rate
2110 (preliminary: MEventRateCalc, MEventRate)
2111
2112 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2113
2114 - added classes dealing with the telescope pointing position (MPointing*)
2115
2116 - implemented the 'final' Mars time stamp based on some experiences with
2117 the new 'Synchonizer'
2118
2119
2120
2121 *** Version 0.8.2 (2003/11/10)
2122
2123 - accelerated standard analysis by a factor of 6-8 ...
2124 + doing precalculations in MGeomCam for the pixel area ratio
2125 + creating a look up table for the single pixels in MCerPhotEvt
2126
2127 - added task to calculates weights in case you want to 'change'
2128 the energy spectrum of a monte carlo file
2129 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2130
2131 - added a new executable star which implements the
2132 star.C macro as precompiled executable. Currently a flexible
2133 setup is not possible, but a 'input card' setup will follow.
2134
2135 - Starting to implement Multi-Telescope-Support based on the
2136 upcomming camera version 0.7. The base for a general support
2137 is implemented and the star-functionality is proven to work.
2138
2139 - Replaced Event-Display in and Camera-Display in the Mars GUI
2140 executable by a more convinient display base on MStatusDisplay.
2141
2142 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2143
2144
2145
2146 *** Version 0.8.1 (2003/10/20)
2147
2148 - added signal subtraction for pure on data by means of fitting
2149 the background in the off region or by performing a combined
2150 signal/background fit. Provides necessary histograms for
2151 obtaining energy spectra and a light curve.
2152
2153 - added classes to perform and study the selection of the
2154 2nd Level Trigger on MC data (example in triglvl2.C macro)
2155
2156 - added pedestal calculation
2157
2158 - implemented "democratic cleaning" (tail cut value proportional
2159 to pixel area) according to Wolfgang's suggestion.
2160
2161 - added Sigmabar treatment (calculation and basic histogramming)
2162
2163 - added basic routines to apply padding
2164
2165 - added first implementation of MARS-based source visibility plotter
2166 (needs to be linked against slalib, preliminary version)
2167
2168 - enhanced functionality of data chains: random numbers, conversion
2169 functions and access to MHMatrix objects
2170
2171 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2172 numbers under certain circumstances (runs with 0 events included)
2173
2174 - fixed a bug in the general filter MF (didn't work on some systems
2175 at all)
2176
2177 - fixed a bug in chaining files, which caused the analysis to crash or
2178 ignore files
2179
2180 - implemented more geometry classes describing the parameters used
2181 to simulate the PMT camera
2182
2183 - added new Monte Carlo classes containing the setup of the different
2184 programs in the MC chain.
2185
2186 - added a (preliminary) general task to evaluate chi-square of a given
2187 parameter in an eventloop.
2188
2189 - first implementation of a container describing the observatory
2190 location (Long, Lat, etc)
2191
2192 - added Random Forest - method for g/h-separation
2193
2194 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2195 (this means, that it is compiling, but not yet fully tested)
2196
2197 - added a new status display which can show the present status
2198 of histograms while an eventloop is running (MStatusDisplay,
2199 an example can be found at status.C)
2200
2201 - reorganized directories:
2202 classes describing the image --> mimage
2203 classes containing Monte Carlo Histograms --> mhistmc
2204 classes for Random Forest method --> mranforest
2205
2206 - added (event-)weights to fill histograms
2207
2208 - colors in logging output to screen
2209
2210 - changes to the Image Parameter declaration:
2211 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2212 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2213 + MHillasExt now derives from MParContainer instead of MHillas
2214 --> Files written with the old definition are more or less unreadable
2215
2216 - reading of reflector files
2217
2218 - display data from reflector files in the camera
2219
2220 - implemented currents (and display them in the camera)
2221
2222 - logarithmic scale in camera
2223
2224 - added class to iterate through directory contents (MDirIter)
2225
2226
2227
2228 *** Version 0.8 (2002/11/18)
2229
2230 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2231
2232 - corrected 48(!) wrong entries in the Next Neighbor table of the
2233 Magic Camera (all in the inner part of the outer ring, mostly
2234 missing a single NN)
2235
2236 - Fixed a bug in the table describing the Next Neighbours of the
2237 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2238 have any neighbour)
2239
2240 - changed trigrate.C: now it calculates the pure NSB triggers from
2241 a camera file (generated with no showers), so there is no need
2242 to introduce them by hand in the BgR array (for more details
2243 please ask Abelardo)
2244
2245 - added MHHadronness (and MHadronness) as a general facility to evaluate
2246 the quality of a gamma-hadron seperation method
2247
2248 - changed MWriteAsciiFile to accept rules (MDataChain)
2249
2250 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2251 must be replaced by calles to MWriteAsciiFile::AddColumn and
2252 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2253 changed.
2254
2255 - Implemented generalized event-matrices (one row per event)
2256 (MHMatrix)
2257
2258 - implemented the one dimensional composite probabilities
2259 (MHCompProb, MCompProbCalc, comprob.C)
2260
2261 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2262 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2263
2264 - Added a camera display displaying the pixel numbers to the
2265 event display gui.
2266
2267 - Added Monte Carlo Informations to event display gui
2268
2269 - Changed the camera display to display the pixel numbering
2270
2271 - Added three buttons to the camera display to change the palette
2272
2273 - Added the number of used and core pixels after image cleaning
2274 to MHillas
2275
2276 - Changed the algorithm used in MHillas according to TDAS 02-03
2277
2278 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2279
2280 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2281
2282 - Added fCosDeltaAlpha to MHillasSrc
2283
2284 - The numbers of photons used to calculate fConc and fConc1 in
2285 MHillasExt are now scaled with the pixel size, so that one get
2286 a four times smaller value for the bigger pixels in the outer ring.
2287
2288 - added new task to smooth the camera contents (MCameraSmooth)
2289
2290 - added possibility to use interpolated pixel values for blind pixels
2291 instead of removing it completely from the analysis
2292
2293 - Implemented the possibility to save the whole eventloop with
2294 its setup to a file. This information can be read and from
2295 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2296 and MEvtLoop::MakeMacro. If you find something not working, please
2297 report - this stuff is still in a beta phase.
2298
2299 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2300 file having crab starfield, but also for all following files - fixed
2301
2302 - MTaskList::PrintStatistics can now be instructud to print also the
2303 title, too: use PrintStatistics(0, kTRUE)
2304
2305 - Changed the image cleaning so that pixels with to many 'used'
2306 neighbors are left used (to get rid of 'holes' in events)
2307
2308 - Introduced more output to the camera displays
2309
2310 - Added an array of histograms (eg one hist per run), MHArray
2311
2312 - Added a _preliminary_ version of the reader for CT1 PreProc files
2313 (MCT1ReadPreProc)
2314
2315 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2316 (thanks to Raquel)
2317
2318 - added the first energy estimator (MEnergyEstParam, estimate.C,
2319 estfit.C) using a parametrization
2320
2321 - Added some new Monte Carlo paremeter containers used to store
2322 setup information from the MC chain (MMcConfigRunHeader,
2323 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2324
2325
2326
2327 *** Version 0.7 (2002/04/30)
2328
2329 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2330 the pedestal mean value was saved incorrectly. For files from
2331 this versions we substract 0.5 from the pedestal mean.
2332 WARNING: This may effect your results, so don't wonder...
2333
2334 - First implementation of an algorithm using only triggered events
2335 for the collection area calculation
2336
2337 - Ascii Output can now also be used for parameter containers which
2338 doesn't overload MParCointainer::AsciiWrite
2339
2340 - The Ascii Output is now also capable of writing single data members
2341 of one container
2342
2343 - You are now able to change the order of the values written to the
2344 ascii file
2345
2346 - You can now specify a conversion factor for each data member written
2347 to an ascii file. This may be usefull to change the units of the
2348 data member (eg. degrees instead of millimeters in case of the
2349 hillas parameters)
2350
2351 - Replaced old MHillas by a new structure which allows you to extend
2352 the parameters stored in MHillas very easily:
2353 see MHillas and MHillasExt
2354
2355 - Added classes to handle source dependancy of image parameters:
2356 see MHillasSrc
2357
2358 - Added container (MBinning) to have a standard input for the binning
2359 in different histograms (eg. the Energy bins should be the same in
2360 all histograms)
2361
2362 - Changed Hillas histograms from mm to deg
2363
2364 - Added the flexible binning to the hillas histograms
2365
2366 - Added a filter for the alpha parameter (MFAlpha)
2367
2368 - It is now possible to write single data members of a class object to
2369 an output stream instead of the whole container only
2370
2371 - Added a generalized filter for a data member:
2372 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2373
2374 - Added a generalized Filter parser for more difficult filter rules
2375 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2376
2377 - Added new Monte Carlo histograms:
2378 MHMcEnergyImpact and MHMcEfficiency
2379
2380 - Added many new histograms needed for the flux calculation.
2381
2382 - Added a generalized histograms which can fill and show up to three
2383 data members in either a one-, two- or three-dimensional histogram, eg:
2384 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2385
2386 - Added:
2387 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2388 * calculation of <Theta> as a function of time (MHThetabarTime)
2389 they are needed in the flux calculation in
2390 order to select for a given bin in Theta (or time) the appropriate
2391 effective collection area, which is assumed to be given as a function
2392 of Theta and the true energy
2393
2394 - Added calculation of the migration matrix in the energy
2395 (MHMcEnergyMigration):
2396 the migration matrix describes the migration from the true (E_true)
2397 to the estimated energy (E_est); it is needed to determine the
2398 distribution of E_true from the measured distribution of E_est
2399 by unfolding
2400
2401 - changed the color palette in the camera display to DeapSea.
2402
2403
2404
2405 *** Version 0.6 (2002/01/15)
2406
2407 - Introduce the option of disable pixels (MBlindPixels and
2408 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2409 able to deal with Star Field NSB.
2410
2411 - Fixed a bug in the pedestals substraction
2412
2413 - Introduced verbosity levels
2414
2415 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2416
2417 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2418 work correctly (thanks to Abelardo)
2419
2420 - Introduced correct treatment of the diffuse Night Sky Background
2421 and NSB (MMcPedestalNSB)
2422
2423 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2424
2425 - Introduced MMcRunHeaders which contains monte carlo run informations
2426
2427 - Added a 'Print'-Task (MPrint) which calls the Print function
2428 of a parameter container for each event
2429
2430 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2431
2432 - changes to be more efficient with root 3.02/06
2433
2434 - root 3.02/06 fixes:
2435 + the memory leak when reading MRawEvtData
2436 + loosing more time than necessary to update the progress bar
2437
2438 - MWriteAsciiFile is now capable of writing more than one container
2439 in a line. For example: To be able to write Monte Carlo and
2440 Hillas values (energy and alpha) in one line.
2441
2442
2443
2444 *** Version 0.5 (2001/11/06)
2445
2446 - Added new GUI functionality (Analysis)
2447
2448 - Added a camera display to be able to display events in the camera
2449 together with the calculated hillas ellipse
2450
2451 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2452 object at any state of the analysis, so that the output are several
2453 states
2454
2455 - Fixed a bug in the collection area error calculation
2456 (Thanks to Ciro and Abelardo)
2457
2458 - Fixed a bug which causes merpp to crash in some environments
2459
2460 - Implemented auto enabling scheme for Branches to speed up reading
2461 a lot (see MReadTree and MTask)
2462
2463 - Fixed a bug in the Histogram classes which caused histograms to
2464 be written to a file by MWriteRootFile without request
2465
2466 - changed the object I/O from the old stylish root I/O to the new
2467 'auto evolution scheme' This was done only for classes which are not
2468 yet used in Monte Carlo files, so that these files are still readable.
2469
2470 - Added support for a progress bar in MEvtLoop and MReadTree
2471 (see the Analysis Window in Mars for an example)
2472
2473 - Fixed a bug in the package creation which disturbed the conversion
2474 between a mars version unpacked from a tar file and the repository.
2475
2476 - Changed the code to writer merpped (converted into root format)
2477 raw files, to get faster (around 10%)
2478
2479
2480
2481 *** Version 0.4 (2001/09/20)
2482
2483 - This release is made to compile on a root version >= 3.00
2484
2485 - Fixed a bug which causes MReadTree to read the first file only
2486
2487 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2488
2489 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2490
2491 - Added a task to write several container to a root file (MWriteRootFile)
2492
2493 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2494
2495 - Added calculation of the collection area (MMcCollectionAreaCalc)
2496
2497 - fixed some bugs in the Hillas calculation
2498
2499 - added filters to be able to control the task execution dependent on
2500 a parameter (for example: the number of level 1 triggers in a MC-file)
2501
2502
2503
2504 *** Version 0.3 (2001/04/23)
2505
2506 - Many demo macros added
2507
2508 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2509
2510 - Hillas Calculation added
2511
2512 - Standard image cleaning available
2513
2514 - MReadTree is now able to handle more than one file
2515 (Remark: of the same structure)
2516
2517 - Now we are able to display events in a first version of the
2518 Camera event display. To do this we must run the macro
2519 "macros/readCT1.C" to read data from CT1.
2520
2521
2522
2523 *** Version 0.2 (2001/01/24)
2524
2525 - First Implementation of a Gui to read the raw data. Start the
2526 gui with the command mars.
2527
2528
2529
2530 *** Version 0.1 (2000/12/20)
2531
2532 - First official release 0.1
2533
2534 - Changes:
2535
2536 + changed calling style of MRawPixelIterator from do...while to
2537 while-loop
Note: See TracBrowser for help on using the repository browser.