source: trunk/MagicSoft/Mars/NEWS@ 8703

Last change on this file since 8703 was 8703, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 108.1 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Now the output files (calib*.root, etc) also contain the
11 resource file (to check it open it in the TBrowser and choose Print()
12 from the context menu)
13
14 - general: Dataset files now allow to overwrite the default path
15 to search for sequence and data files. Note, that the program
16 option and individual resources will overwrite it. For example:
17 SequencePath: /magic/montecarlo/sequences
18 DataPath: /magic/montecarlo/star
19
20 - general: Fixed a problem with variables in MDataPhrase. It seems
21 that only optimdisp (didn't work) was effected.
22
23 - general: Some improvements to the optim and train processing. For
24 example the ststud window now got a proper title.
25
26 - general: The "Status Display: " was removed from the window title
27 within an Eventloop.
28
29 - general: added a new flexible histogram-class (MHn) which can be used
30 for example in testing after optimizations or training to produce
31 user defined histograms.
32
33 - merpp: Merpp can read file format version 9 now. Please realize
34 that for file format version 9 the extraction range is different
35 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
36 the first and last 15 slices have been removed from all MUX data.
37
38 - mars: Similar to writing movies you can now select events which
39 should be displayed in your display. Therefore add the following
40 lines to your mars.rc:
41 MFEvtNumber.FileName: ganymed00223552.root
42 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
43 The input file can be a ganymed-file after (ganymed*.root) or
44 before (ganymed*-summary.root) file. For example to select all events
45 from your on sample after cuts (excluding the ThetaSq cut) use
46 MFEvtNumber.Selector: DataType.fVal>0.5
47 To show all events from your on-sample after quality cuts
48 use the summary file instead.
49
50 - mars: new ways to call mars are implemented. Instead
51 of calling
52 mars filename.root
53 you can now also use
54 mars sequence.txt
55 or
56 mars sequence.txt inputpath
57 or replace sequence.txt by the sequence number if the default
58 sequence file should be used.
59
60 - mars: The default size has been increased
61
62 - mars: There are two new heckboxes which allow to switch off
63 the calculated image parameters
64
65 - callisto: was broken for MCs... fixed.
66
67 - callisto: improved calculation of spline coefficients a lot. This
68 leads to a further improvement of the event rate calibrating MUX
69 data of about 15% (175evt/s instead of 150evt/s)
70
71 - callisto: finally the raw data we read is now real 16bit (with
72 10bit precision) for MUX data and not a stripped 8bit number
73 anymore. Due to scaling of the numbers (without precision loss
74 into an [0-256[ range, the final numbers for pedestal, pedestalrms
75 and extacted signal don't change. However, at all places where
76 raw data is directly accessed (eg. saturation and variation
77 limits in the signal- and pedestal-extraction) the numbers
78 refer still to the data's 16bit range.
79
80 - callisto: The maximum arrival time difference used in the bad
81 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
82 for both, old FADC and MUX-FADC, data.
83
84 - callisto: Be aware that callisto is now calibrating the arrival time
85 in nanoseconds rather than time slices. Also all following tasks
86 have been changed to assume ns units now. If you star data
87 calibrated with an older version it might be necessary to adapt
88 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
89 to obtain optimal results. The plot in the PulsePos tab
90 will now be in ns, too. This might also mean that the Muon
91 analysis in star might not work as perfect as expected as long
92 as old files read in.
93
94 - star: For speed reasons events suitable for the muon analysis
95 are now also preselected by fConcCOG<0.1 which seems to be a very
96 good preselector for muons.
97
98 - star: is now calculating a new timing parameter the Slope along
99 the major and minor axis of the shower. Therefore a numerical
100 solution of a line-fit is used. To use MHillasExt.fSlopeLong
101 and MHillasExt.fSlopeTrans don't forget to multiply it with
102 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
103
104 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
105 have been removed from MNewImagePar. They have never been good for
106 anything.
107
108 - star: Implemented a new recursive algorithm which is supposed to be
109 faster. Also implemented new cleaning oiptions, which are:
110 + CleanLevel0:
111 The cleaning level above single core pixels can be kept
112 + KeepIsolatedPixels:
113 Define whether single core pixels should be kept
114 + TimeLevel1:
115 The coincidence window in nanoseconds to single used neighbors
116 + TimeLevel2:
117 The coincidence window in nanoseconds to two used neighbors
118 + PostCleanType:
119 MOde in which a time dependent post cleaning should be applied
120 0: No post cleaning
121 1: Require for each used pixels at least one used neighbor
122 within a time-window of CleanLevel1
123 2: Require for each used pixels at least two used neighbor
124 within a time-window of CleanLevel2
125 3: Require first two and second one used neighbor
126 within a time-window of CleanLevel1 and fCleanLevel2
127 respectively
128 + RecoverIsolatedPixels:
129 - recoveres isolated core pixels if they have a used neighbor
130
131 - mars/star: The new default cleaning is:
132 + CleanLevel1: 6.0
133 + CleanLevel2: 3.0
134 + CleanTime1: 1.75
135 + CleanTime2: 1.75
136 + PostCleanType: 3
137
138 - star/ganymed: The old spark-cuts have been replaced by new ones.
139 These new spark cuts have been cross checked with the sequences
140 84720 (before splitter), 101041 (after splitter) and 223539 (new
141 FADCs). In all cases they seperate pretty well, but of course not
142 perfect. Monte Carlos have suggested to tighten the cuts a little
143 bit further at low sizes. This has been done.
144
145 - ganymed: IMPORTANT - The spark cuts have been changed to match
146 all available data more or less well. This might mean that for
147 YOUR data there are still sparks visible.
148 Whenever you do an analysis you have to make sure that NO sparks
149 survive your cuts!
150
151 - ganymed: The old hadronness and size cuts have gotten new indices
152 (10, 11). The old indices 8 and 9 now mean an additional condition
153 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
154 If you want to switch off this cut just move the line far away enough,
155 e.g. by setting c[9] to -500. Please update your ganymed.rc files
156 accordingly!
157 The unit of c[9] is deg. It is the dist at which your cut will
158 cross the slope==0. The unit of the slope is ns/deg. So if
159 you readin files calibrated with an older Mars-version you
160 have to adapt the default value for c[9] to the FADCs:
161 - Multiply by two for the MUX FADCs (run number > 200.000)
162 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
163 - Multiply by 42 for the meaning of life (run number = 200.000)
164
165 - ganymed: The old Cut0 is now called CutQ and is calculated before
166 the source position is caluclated. If you need a quality cut
167 including source dependant data (be very carefull with this!)
168 you have to use Cut0 instead.
169
170 - ganymed: now properly supports three off regions in wobble mode.
171 It will be the default from now on in ganymed_wobble.rc. To change
172 the number of off-regions use
173 NumOffSourcePositions: 1
174 in your ganymed.rc. Also by default no off-theta cut will be done
175 anymore so that you will get a background level higher than the
176 signal level in your ThetaSq plot for ThetaSq>0.2.
177 Due to this be carefull changing the scaling mode away from
178 "None". You will underestimate your signal if your scale interval
179 is not properly set.
180 (Rem: ThetaSqN is no longer needed)
181
182 - ganymed: is now storing the events of all (on- and off-)
183 source positions even in the case of more than one off-source
184 position. This should allow sponde to work properly and the
185 energy estimation is done correctly in all cases (without any
186 "nearest position" trick)
187
188 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
189 with a real pointing model for the starguider is done, calibrated
190 with more than thousand tpoints taken from this date on.
191
192 - ganymed: was broken for Wobble-MCs... fixed.
193
194 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
195 has changed. Note that your old ganymed.rc will be incompatible
196 with the new algorithms! Please check the ganymed.rc files and
197 the class description of MFMagicCuts for more information.
198 It is recommended at the moment to use identical Disp-Parametrizations
199 for on/off- and wobble-mode. If cuts are optimized only
200 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
201 should be optimized. All other values should be kept as they are.
202 If you want to do an anylsis without timing a parameters, you can
203 switch off the timing cuts by seeting parameter 7 to a very small
204 value (eg. -99). To remove the slope parameter from the disp
205 paremtrization set parameter 8 to 0.
206
207 - ganymed: The distribution of observation time versus zenith
208 angle is now shown for off- AND on-data.
209
210 - ganymed: The contents of the source position plot are no longer
211 averaged, thus a lot of (fake) events between the two wobble
212 positions have disappeared.
213
214 - optim, sponde: should now properly support three off-regions.
215 Just produce your ganymed summary files with three off-regions.
216 optim and sponde will automatically get all off events from
217 all off-regions from this file. Please do not forget to
218 set the scaling in optimwobble.C properly:
219 fit.SetScaleUser(1./3);
220 it is not yet read in automatically (will follow soon).
221 In the case of fixed Scale you can also use
222 cuts.SetThetaCut(MFMagicCuts::kOn);
223 no off-cut needed.
224 Be carefull in case of three off-regions when switching on
225 scale mode. Make sure that the scale interval is set correctly.
226
227 - sponde: In the estimated energy versus monte carlo energy plot the
228 contents where exchanged.... fixed.
229
230 - sponde: the so called "accurate"-mode has been removed. It didn't
231 give any improvement in accuracy, only decreased execution speed.
232
233 - sponde: the so called "simple"-mode has been removed. It didn't
234 give any improvement in simple.
235
236 - sponde: the so called "refill"-mode has been removed. It was anyhow
237 not implemented.
238
239 - sponde: now checks whether the theta distribution of your on-data
240 and the theta-distribution of your Monte Carlo sample (after
241 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
242 sample is incomplete) execution is stopped. Execution can be forced
243 using the new option --force-theta. Use this option with care!
244
245 - sponde: Proper collection areas can now be constructed also from
246 Monte Carlo samples generated with different maximum impact
247 parameters. Note that in previous version you neither got
248 a warning or failure, nor was there any obvious sign that the
249 collection area was overestimated due to usage of files with
250 different maximum impact parameters.
251
252 - sponde: If MC files with different lower energy limits are used
253 the primary MC spectrum is artificially completed down to the
254 lowest energy used at all. WARNING: that this gives correct
255 collection areas ONLY if none of the events in this region would
256 survive your cuts at all.
257
258 - sponde: the output file now contains more information about
259 the spectrum (eg. the full 2D collection area histogram).
260 Note, that this information can only be written to the file
261 if it is stored automatically via command line argument.
262 If you only store the status display from within the display
263 the information is lost.
264
265 - sponde: added a new tab "Energy". It shows the residual of the
266 energy (lg(estimated energy)-lg(monte carlo energy)) versus
267 several parameters and it is meant to judge the quality of the
268 energy estimator. In the ideal case the residual is zero
269 and doesn't depend in the variable. In reality even a good estimator
270 can show residuals versus Monte Carlo energy.
271
272 - sponde: added a new tab "EventDist" showing the unweighted real
273 absolute number of events of your sample after cuts. This tells
274 you how many events with this energy you had in your MC files.
275 The same information you get from the error bars of the weighted
276 histograms, but this is less intuitive.
277
278 - sponde: The spectrum plots now show the crab- and 1553-spectrum
279 for comparison. It is not meant to show these curves in
280 publications, they are only for production.
281
282 - sponde: The OriginalMC tree with the events produced by corsika
283 is now processed only once
284
285 - sponde: Finally fixed most annoying bug, which has effected the
286 last bin of the collection area. It was the problem that binnings
287 of root histograms are from 1 to n (included) but there was a C-like
288 loop in sponde from 0 to n (excluded). Now the loop also includes
289 correctly under- and overflow-bins. The worse thing with this is,
290 that for the events in the highest bin not only the bin-content
291 was wrong, but also the weights applied to these events, which could
292 in pricipal effect also other parts of the distribution (eg. due
293 to energy estimation). Fortunately it effected only a few events
294 in most cases.
295
296
297
298 *** Version 1.2 (2007/05/14)
299
300 - database: The database now has two new values Unsuitable50 and
301 Unsuitable01. They express the number of pixels which are
302 unsuitable for more than 50%, respectively more than 1%, of
303 all calibrated event. It is a more accurate number than the
304 previously used numbers, because they only take the first
305 calibration (ignoring the interleaved calibrations) into account.
306
307 - database: The database now has two other new values UnsuitableMax and
308 DeadMax. They express the maximum number of pixels which were
309 unsuitable, respectively dead, during the sequence. Because
310 of high pedestal rms (cars passing) a few events with very high
311 numbers of unsuitable pixels can happen. Not to suffer from this
312 effect we don't take the highest 0.1% of the numbers into account.
313
314 - general: fixed a bug which caused callisto and star to stop working
315 properly because the callisto output was currupted
316
317 - general: a script called scripts/makemovie has been added which
318 simplified the process of producing several movies from a single
319 sequence with different setup.
320
321 - callisto: Some more code cleanup. Started to remove old obsolete
322 code from cvs.
323
324 - callisto: The extraction of the pedestal with the extractor was
325 not random. It seems that extracting at one position is still biased
326 (for example in the first or last slices we could still suffer from
327 switching noise) Now it is completely random.
328
329 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
330 pedestal files) individual pixels could be skipped due to high
331 variations. This was already the case for the pedestal extraction
332 from the lo-gains since the beginning and properly handled
333 there, but was introduced in the extraction from the pedestal files
334 a while ago. To calculate the average value it was still divided
335 by the number of events procesed not by the number of summands
336 really summed. This let to a pedestal which was a tiny amount too
337 small (for a few piels in the order of 0.1%). This led to an slightly
338 positive offset of the randomly extracted pedestal for a few pixels.
339 I doubt that this has a big effect on the result, because the effect
340 on the individual numbers is quite small. Due to this it is suggested
341 that you rerun your calibration to make sure you are without any
342 avoidable bias.
343
344 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
345 the median rms of the absolute arrival time and expressed in significance
346 levels. This replaces the old meaning of an abolute upper limit. An
347 absolute upper limit doesn't make much sense, because in our data
348 all arrival times are shifted at the same time (in fact it might be
349 a shift of the artificial trigger w.r.t. to the light flash).
350
351 - callisto: Added a new tab "BadPixTm" which shows the time evolution
352 of the number of unsuitable pixels over the whole sequence. This
353 is usefull mainly to judge if an intermediate calibration had
354 problems.
355
356 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
357 of the number of dead pixels over the whole sequence. Dead pixels
358 in this context are unmapped pixels, i.e. pixels which could not
359 be interpolated, and thus are ignored in the further analysis.
360
361 - callisto: It is now possible to use the position of the maximum
362 of the spline as arrival time instead of the leading edge even
363 when using the integral for the signal. Therefor set the extraction
364 type to kIntegralRel ("IntegralRelative") and the relative height
365 ("HeightTm") to -1:
366 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
367 MJPedestalC1.ExtractSignal.HeightTm: -1
368
369
370
371
372 *** Version 1.1 (2007/04/27)
373
374 - general: The new class MGeomCamDwarf contains the camera geometry
375 for our prefered Dwarf camera and can be used to create general
376 geometries of roundish or hexagonal cameras.
377
378 - mars: The default cleaning is now abolute 8.5/4.0.
379
380 - mars: The resource file mars.rc now contains examples for MUX data
381
382 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
383 data containing only 10-bit information is still cooked down to
384 8-bit, by cutting away the lowest 8-bit.
385
386 - merpp: When reading raw data the data is now stored in a single
387 array. The lo-gain array is obsolete. The interface stays the same.
388
389 - callisto: To process the new MUX data use the resource file
390 callisto_mux.rc
391
392 - callisto: The -root and -raw options to read merpped raw data have
393 been removed
394
395 - callisto: If the -mc option is given the sequence-name can now be
396 replaced by the MC sequence number
397
398 - callisto: If the sequence file contains "MonteCarlo: Yes" the
399 -mc option can now be omitted
400
401 - callisto: Started further simplification by removing obsolete
402 dependancies on MCalibIntensity*Cams.
403
404 - callisto: removed unsused intensity calibration from MJCalibration
405 for further simplification
406
407 - callisto: for simplification removed references to
408 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
409 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
410 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
411 (this should at minimum change nothing at all, and at maximum
412 improve thing if these containers where somewhere not handled
413 properly)
414
415 - callisto: Added the option to write an event movie. Please use
416 this option with care (huge files) but exessively to understand
417 our events. For further documentation please refer to the
418 IACT wiki
419 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
420
421 - callisto: Improved binning for the pulse position check histogram
422
423 - callisto: The code calculating the pulse position checknow takes
424 the pedestal into account
425
426 - callisto: The arrival time is now stored with full precision this
427 helps to get rid of artefacts in histograms. For the signal this
428 is not necessray because it is displayed in log-scale anyhow
429
430 - callisto: Fixed a problem with internal exclusions. Pixels which
431 have once been marked as unsuitable didn't get the necessary
432 histograms filled anymore to be rechecked with each interleaved
433 calibration.
434
435 - callisto: The relative arrival time resolution (the rms of the
436 relative arrival time offset) is now checked against its
437 median and the median deviation, instead of the average
438 plus an absolute offset.
439
440 - callisto: The relative arrival time offset is now calculated
441 w.r.t. its median not w.r.t. to an artificial reference pixel.
442
443 - callisto: The relative time calibration now marks pixels with
444 outlaying offset as unsuitable
445
446 - callisto: The interleaved relative time calibration has been switched
447 on. The advantage is that pixels which are marked as outliers
448 now can recover. An improvement over time is not expected, because
449 the relative time calibration seems stable.
450
451 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
452 option can now be omitted.
453
454 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
455 or the option "-mc" is specified as default the monte carlo datacenter
456 paths (/magic/montecarlo/...) are used if not overwritten in the
457 dataset file.
458
459 - ganymed: The output files now contain run- and event-number for all
460 events, accessible as RunNumber.fVal and EvtNumber.fVal
461
462 - ganymed: Added a plot showing the source position in the camera also
463 for wobble mode
464
465 - ganymed: In addition to the existing task which can be setup to
466 be executed after Cut1 a final task called "EstimateEnergy"
467 has been added, executed before writing the final output
468 (ganymed00000000.root). The task setup in all three cases
469 can be choosen individually. (For all three(!) cases you
470 can for example choose MRanForestCalc. For examples see all
471 sponde*.rc and all ganymed*rc)
472
473 - ganymed: If a container "MEstimatedEnergy" is found in the
474 parameter list (eg. because it was setup by MEstimateEnergy)
475 it will be written to the output file.
476
477
478
479 *** Version 1.0 (2007/02/16)
480
481 - database: Website to plot values from the database has been added.
482
483 - database: The rate of spark events as found by star is now kept
484 and the rate after cleaning is now with spark events subtracted
485
486 - general: The changes to the interpretation of phrases lead to
487 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
488
489 - general: Added example files how you can create your own calendar
490 (eg. as christmas present) with Mars. Just run
491 root macros/tutorials/calendar.C
492
493 - general: Added a possibility to display grouped data in the plotdb.C
494 macro (and similar macros). This allows to plot hourly, nightly,
495 weekly, monthly and yearly averages.
496 For more details see the plotall function of the macro
497
498 - general: fixed the error display of the camera display. It showed
499 wrong results.
500
501 - general: fixed a memory leak when reading many MStatusDisplays
502
503 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
504 between a spherical and a parabolic mirror
505
506 - callisto: We have a new pulse position check which takes the properties
507 of the extractor automatically into account. So no need to set
508 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
509 left is done. If possible the lo-gain extraction start and hi-gain
510 extraction end is changed accordingly. If no proper extraction range
511 can be set (hi-gain too much to the left) an error is raised.
512
513 - callisto: New swapped pixels have been found and corrected
514
515 - callisto: Redone the signal extraction this includes:
516 + Unified the algorithms to extract the pedestal for all pedestal
517 extractions done
518 + Unification of hi- and lo-gain into one array
519 + Unification of hi- and lo-gain extraction for Spline and
520 Digital Filter (means now exactly the same algorithm is used,
521 not a copy-and-pasted one)
522 + Store pedestal subtracted data in a common place
523 + Improved extraction algorithms. If the algorithms search a
524 maximum but don't find one they don't return the maximum anymore
525 + Improved the extraction such that a information for signal
526 and time which is consistent is returned
527 + replaced the numerical spline with a (not slower) analytical
528 solution
529 + Lowered the saturation limit from 250 to 245 to make sure that
530 we are far away in all pixels from problems with the clock-noise
531 + The start of the lo-gain extraction is calculated from the hi-gain
532 arrival time. In case of saturation an estimation is used.
533 + the hi-gain window was extended to slice 16. This allows extraction
534 of very late pulses in single pixels or of huge hadron showers.
535 + Now uses the lo-gain extraction range for pedestal extraction,
536 not the hi-gain range in the lo-gain
537
538 - callisto: New hi-/lo-gain calibration constants have been produced
539 for all periods from the statistic of the whole period. They are
540 now used automatically depending on the periods. The old constants
541 where deviation in avarega about 2%-3%. The constants are very
542 stable from period to period (<<1%) except for exchanged channels.
543 In a few cases the constants used so far were off by 1%-2% (maybe
544 temperature effects?)
545
546 - callisto: To gain obsolete space we do not write the
547 MPedestalFundamental anymore. Also calibration and bad pixel
548 treatment is not done for it anymore because it has never been used.
549
550 - callisto: Fixed a bug in the seuqence handling which caused the
551 light condition to be ignored
552
553 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
554 basically the same as "Cleaned" but the distribution devided into
555 the events fullfilling a spark cut or being rejected by it.
556 This cut can be changed from star.rc (see example inside) by
557 the "SparkCut" directive
558
559 - star: Star displays now the average individual pixel-rate (IPR) versus
560 time and the average discriminator threshold (DT) of all pixels.
561
562 - optim: fixed a problem with the optim-macros which was due to a bug
563 in the new phrase parsing
564
565 - ganymed: To get a nice FalseSource plot (instead of the all-information
566 debug plot displayed as a standard plot) use the context menu
567 somewhere between the two upper plots, click on "DrawNicePlot"
568 and enjoy the result. (It is the same context menu which contains
569 the other options)
570 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
571
572 - ganymed/optim/train: The cut program, trainings- and optimization
573 macros could run with less files found than expected from the
574 sequence-files. No the execution is stopped in this case.
575
576 - ganymed: now stores the dataset in the output file with all information
577 contained (as sequence number, sequence path, data path) so that the
578 used dataset file can be recreated complete from the output
579
580 - sponde: now also allows the uasge of random forest
581
582 - sponde: added a plot showing the cut efficiency
583
584 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
585 errors (eg. effecting the collection area) because the errors of the
586 two histograms were swapped in the calculation, which makes a difference
587 in the case the histograms contains weighted events. Aditionally the
588 totalarea was incorrectly taken into account, which results in too small
589 errors, which makes a difference at low statistics were the errors
590 or the collection area dominate.
591
592
593
594 *** Version 0.10.3 (2006/10/23)
595
596 - database: Implemented ObservationMode flag in websites.
597
598 - database: For sequences there is now also the stoptime available on the
599 websites.
600
601 - database: Removed ManuallyChanged flag from sequence-info websites,
602 as it is not needed anymore with the new sequence building algorithm.
603
604 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
605 Class for calculation of confidence intervals (upper limits).
606 Use model 3 or 4 for upper limit calculation for MAGIC observations.
607 Please read the class instruction of TRolke for more information.
608
609 - general: The programs now return 0xfe if the requested resource file
610 doesn't exist.
611
612 - general: Errors comming from root itself are now not output to
613 stderr anymore but to our default (colored) log-stream.
614
615 - general: Changed the interface to TFormula such that now everything
616 is parsed by TFormula, which should allow to use phrases even
617 without paranthesis correctly parsed.
618
619 - callisto: replaced the AdHoc number of effective integration slices
620 in the digital filter by an average of the correct number, averaged
621 over all possible set of weights. This also gives correct numbers
622 for the lo-gains which were totally wrong before.
623
624 - callisto: drastically reduced memory consumption by not storing
625 all intermediate calibration results in memory anymore (we might
626 write them into a file in the future)
627
628 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
629 debug plot displayed as a standard plot) use the context menu
630 somewhere between the two upper plots, click on "DrawNicePlot"
631 and enjoy the result. (It is the same context menu which contains
632 the "DrawAll" option)
633 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
634
635
636
637 *** Version 0.10.2 (2006/10/15)
638
639 - general: changed the building of the sequence files such, that
640 the source-/project name in case of wobble-sources is not the
641 source/project of the first data run anymore but the new generalized
642 wobble source/project
643
644 - general: Added some functions to MAstro to calculate sun and
645 moon properties
646
647 - general: Added two new macros (starvisday.C and starvisyear.C)
648 which allow to plot the visibility of several stars in one day
649 or of one star along one year
650
651
652
653 *** Version 0.10.1 (2006/10/11)
654
655 - general: HTML logging output was distorted... fixed.
656
657 - general: Changed the writing of the sequencefiles such that only
658 as many pedestal files as giving at least 1000 pedestal events which
659 are nearby the first calibration run are used as pedestal runs
660
661 - sponde: In the calculation of the collection area(s) and the
662 distribution for MOnte Carlo and estimated energy the error
663 calculation was wrong because root didn't take the errors
664 properly into account... fixed.
665
666
667
668 *** Version 0.10 (2006/10/10)
669
670 - general: all executables now check consistency of the root version
671 installed with the root version used for compilation. The return
672 code in this case is 255.
673
674 - general: The algorithm to build seqeunces has been redesigned
675 completly. It is now more flexible in terms of a resource file
676 resources/sequences.rc which can be used to partly overwrite
677 the default algorithm and defined the important part of the
678 algorithm. It also takes correctly into account several ways
679 of taking wobble-data. Currently the new algorithm doesn't take
680 the number of pedestal events anymore into account (so a sequence
681 could have much less than 1000 pedestal events and data runs are
682 no-more used instead)
683
684 - general: a lot of small changes to make the code compatible with
685 root 5.12/00 and gcc 4.1
686
687 - general: Fixed some warnings thrown if more warnings are switched
688 on in the compiler
689
690 - general: Added a function to MMath which returns the Median of
691 the distribution abs(y[i]-median) but at 68:32 division instead
692 of 50:50, which is somehow the median counterpart of the rms.
693
694 - general: MAstroCatalog allows now to read calatog files (as bsc5)
695 even if they are compressed with gzip (recommended compression
696 is with "-1")
697
698 - showplot:
699 + batch mode creation of image files now works with root 5.12/00
700 + added support for writing bmp (though it never produces
701 bmp which can be read by programs like xv or gimp)
702 + added support for xml
703 + added new option to start the display with a different size, by
704 --display-width=nnn or --display-height=nnn
705 + added options to define the canvas size when the display is started
706 --canvas-width=nnn or --canvas-height=nnn
707 the option can also be used for batch-mode conversion
708 + added an option which automatically fits the display size to the
709 desktop-size: --auto-size
710
711 - merpp: didn't recognize files with the extension .raw.gz - fixed.
712
713 - merpp: allow the reports to have 1000ms due to a bug in the camera
714 program.
715
716 - callisto: New swapped pixels have been found and corrected. For
717 details see MRawRunHeader::FixAssignment()
718
719 - callisto: Callisto now raises an error if one of the input files could
720 not be opened.
721
722 - callisto: In some rare cases it could happen that in the signal
723 extraction of the digital filter the extractor returned nonsense
724 results due a wrong initializion of a variable (this happens in
725 cases in which the extracted signal is exactly zero or the
726 digital filter couldn't slide because of a too small extraction
727 window, which could happen in the lo-gain extraction)
728
729 - callisto: The lo-gains have been marked as valid in some cases
730 when they got not extracted at all (deltsumlo=deltatimelo=0) because
731 the allowed extraction range (fLoGainLast-fLoGainFirst) was
732 smaller than the number of slices (fLoGainWindowSize) needed
733 by the lo-gain extractor
734
735 - callisto: Updated absolute calibration constants (muon calibration)
736
737 - callisto: fixed a bug which caused the hi-gain saturation not
738 to be handled properly in the spline (the position of the
739 saturation was calculated incorrectly)
740
741 - callisto: fixed a bug which gave weird results if hi- _and_
742 lo-gain could not be extracted properly. In some cases hi-
743 and lo-gain have not been extracted at all and the random result
744 got calibrated. In other cases the hi-gain was saturating and the
745 lo-gain has not been extracted. For this a completly arbitraty
746 scale factor was applied to the result from extracting the
747 charge of the saturating hi-gain.
748
749 - callisto: improves handling of extracted signal if lo- and/or
750 hi-gain could not be extracted properly. If no appropriate
751 calibration of either the signal or the arrival time is possible
752 the pixel is now markes as unsuitable instead of estimated.
753
754 - callisto: Fixed a problem in the spline extraction which gave
755 weird results if the signal was extracted from the first (and
756 highest) slice (as a workaround extraction from the first
757 slice has been forbidden)
758
759 - callisto: Fixed a bug regarding the use of the QE which doesn't
760 effect the result because the default is used anyhow.
761 (The bug was there since 14/07/2005)
762
763 - callisto: Changed the default for fgLoGainStartShift to -2.4
764
765 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
766 factors to be always 10 for all pixels as soon as the first
767 calibration update has happend.
768
769 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
770 was off by more than one slice (which gives wrong values for
771 pixels which have saturated the hi-gain) This was a problem
772 mainly for timing studies, not so much for the automatic standard
773 analysis. Also the values for the Spline have been changed slightly:
774 + Digital Filter from 1.70 to 0.95
775 + Spline from 1.39 to 1.30
776 The numbers were sorted out by an extensive test in the
777 test-database.
778
779 - callisto: Removed the tab showing the average calibrated arrival
780 time. It never gave useful information.
781
782 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
783 lo-gain pulse for data pulses if hi- and lo-gain have saturated
784 and both were extracted because the hi-gain was above the
785 LoGainSwitch.
786
787 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
788 lo-gain pulse position (after application of LoGainOffset, which
789 means in the ideal case it is 0) for data pulses if hi- and lo-gain
790 have saturated and both were extracted because the hi-gain was above
791 the LoGainSwitch.
792
793 - callisto: After extensive tests a new threshold level for determination
794 of the pulse position has been found at 50phe. This is due to the
795 fact that for lower pulses the arrival time changes its average
796 behaviour dramatically. It tends to the average of the extraction
797 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
798
799 - callisto: Added two more plots to the calibration part. The average
800 extracted signal and the average extracted arrival time as
801 extracted by the signal extractor (This can help debugging problems
802 because it doesn't involve a fit)
803
804 - star: changed the fit for the effective on time such that initial
805 values are calculated automatically now instead of using build
806 in values. This makes the fit more indepedant of the underlaying
807 rates. With a test of ~350 sequences in the test database it could
808 be shown that the new fit gives the same result +/-1sek.
809 The highest deviation was +5s the lowest -10s. You can now control
810 the bahaviour with two resource values:
811 MHEffectiveOnTime.FistBin: 3
812 MHEffectiveOnTime.NumEvents: 12000
813 Use FirstBin=1 and NumEvents=120 to fit the effective on time
814 from the resulting gamma candidates
815
816 - star: The Center histogram in MHHillas is now by default displayed
817 with the colz draw-option
818
819 - ganymed: now produces valid error codes if failed
820
821 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
822 with the option "hadronness" instead of "area" or "both" if
823 you want to use both cuts. The hadronness cut includes a fixed
824 cut in hadronness (index 8) and a fixed cut in size (index 9).
825
826 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
827 the M3Long of the anti source to be not properly evaluated
828 (actually is was evaluated as a unique random number) in case
829 of optimization with anti-theta cut switched on. This might have
830 lead to improper, but not necessarily wrong, optimization results.
831
832 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
833 how to use random forest
834
835 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
836 ganymed_onoff.rc. Seems to be unintentional that they were different.
837
838 - sponde: Since the introduction of the possibility to define a
839 normalization energy instead of using the integral the default
840 was not using the integral anymore but a normalization energy of
841 1GeV. It is now the integral again.
842
843 - sponde: Fixed a problem in the weighting which did not allow
844 a MC slope of -1.
845
846
847
848 *** Version 0.9.6 (2006/05/24)
849
850 - general: changed the binning of the azimuthal profile of the camera
851 such that it is aligned with the 60deg boundaries.
852
853 - merpp: better handling of problems with the TH, TD part of the
854 CC-REPORT for files older than 200507190 and 200412210
855 respectively
856
857 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
858
859 - merpp: implementd latest changes in starguider reports (sinc 9th May)
860
861 - callisto: if an arrival time is extracted outside the fadc range is
862 was set to the boundary before. Now a random number is assigned
863 instead to avoid unfortunate coincidences of arrival times just
864 by this arbitrary value.
865
866 - callisto: added a new option to callisto.rc which allows
867 to set the maximum arrival time difference allowed for the
868 badpixel algorithm to determin whether a pixels belongs to a shower:
869 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
870
871 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
872 to 0.9 as suggested by Stefan due to a recent study on the fraction
873 of pixels surviving the image cleaning
874
875 - callisto: switched off error in case of "pulse is too much to the left"
876
877 - callisto: The extraction window is not adapted anymore. This means that
878 the pulse is extracted from the full range. The draw-back is that the
879 background (pedestal) will become slightly higher. Switching on/off
880 the PulsePosCheck in the callisto.rc only effects filling the
881 histograms.
882 WARNING: If the pulse is too much to the left data is calibrated!
883 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
884 in the database to make sure that your data is valid!
885
886 - star: Show also the number of stars correlated correctly by the
887 starguider
888
889 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
890 than one off-source region in wobble-mode. To use it add the following to
891 your ganymed_wobble.rc:
892 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
893 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
894 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
895 + Cut1.ThetaCut: None
896 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
897
898 - ganymed: in the case the latest report is older than a default (currently
899 one minute) and the current report will be skip the starguider
900 correction and calibration will be reset. The maximum age can be
901 setup from ganymed.rc by (minutes):
902 MPointingDevCalc.MaxAge: 1.5
903
904 - ganymed: A first implementation showing all size-bins for the theta-sq
905 resp. alpha-plots in a single tab automatically
906
907
908
909 *** Version 0.9.5.1 (2006/05/05)
910
911 - general: Added a new option "zdiff" to the Makefile which runs
912 "cvs diff" as "make diff" would do, but with compression
913
914 - general: accelerated MTFillMatrix (used for eample in all training
915 and optimization macros) by skipping some obsolete calles in the
916 eventloop the first and second loop could be accelerated by ~20%
917
918 - general: Added a missing feature in the MFilterList class which
919 prevented MFEnergySlope from working correctly in trainenergy.C
920
921 - general: Accelerated the random forest training and usage a bit
922
923 - merpp: Adapted to new raw data file format version 6
924
925 - merpp: fixed a problem with reading the starguider reports
926 after 6.3.2006
927
928 - callisto: At some times six pixels had to be exchanged manually in the
929 data. If the pixels to be swaped are both not found, an error was raised
930 and calibration was stopped. Now it is assumed they are intentially not
931 mapped and the Error has been changed to a Warning.
932
933 - star: Added new image cleaning based on the arrival time of the shower.
934 The new cleaning can be accessed using the parameter "Time" instead of
935 the the old one (like "Absolute) in the star.rc-file.
936 Recommended parameters:
937 + MImgCleanStd.CleanLevel1: 8.2
938 + MImgCleanStd.CleanLevel2: 5
939 + MImgCleanStd.CleanRings: 2
940 + MImgCleanStd.KeepSinglePixels: No
941
942 - star: Simplified the calculation of the effective on time. By letting
943 the fit start in the third bin the result should become more stable.
944 The fit quality is now ignored for the theta-plot which is not used
945 in the analysis later. Still better pre-cut which, for example,
946 remove events triggered by car-light (rate changing on a short
947 time-scale) are missing.
948
949 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
950 for optimization (kWeakSource) which is suggested by the Berlin
951 people for weak sources.
952
953 - macros: plotdb.C:
954 + if no dataset and no time-interval is given only sequences with
955 an effective on-time above five minutes are plotted anymore
956 + added a new tab "RelTime" displaying the relative on-time
957 (effective on-time divided by the observation time)
958
959 - macros: optim*.C: by skipping some obsolete calles in the eventloop
960 the optimization became a lot faster
961
962 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
963 To display them just delete the pads displayed on top.
964
965 - ganymed: fixed a bug which could cause strange behaviour in wobble
966 mode if no starguider information was available due to an incorrect
967 initialization of the starguider calibration
968
969 - ganymed: The scale region in the False Source Plot (MHDisp) can now
970 be changed from within the plot. It can also be setup from the
971 resource file using:
972 + MHDisp.fScaleMin: 0.325
973 + MHDisp.fScaleMax: 0.475
974
975 - ganymed, showplot: Fixed a problem with the fit to the off-data
976 (HistOff) which could cause a time lag or an inifinite loop.
977 The bug did not effect the results at all.
978
979 - sponde: Added a new tab showing the effective collection area after
980 trigger (including the software trigger)
981
982 - sponde: MMcSpectrumWeight has a new option which allows to define
983 the scaling factor not by the integral of the events but at
984 a defined energy:
985 e.g. MMcSpectrumWeight.NormEnergy: 200
986
987 - MTFillMatrix, sponde: by skipping some obsolete calles in the
988 eventloops the loop could be accelerated by ~20%
989
990
991
992 *** Version 0.9.5 (2006/03/13)
993
994 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
995 and added the standard Disp-parametrization
996
997 - macros: added a new macro datacenter/macros/plotstat.C allowing
998 to plot statistics about the data processing
999
1000 - macros: added a new macro to plot the muon correction coefficients
1001 versus period (macros/plot/mucal.C)
1002
1003 - showplot: path inflation for ganymed files was broken
1004
1005 - callisto: Fixed an important bug. When the number of saturating pixels
1006 were calculated the bad pixel information already available from the
1007 calibration was ignored. This yields wrong values in case pixels
1008 are broken and saturate all the time or randomly.
1009
1010 - callisto: Updated Muon calibration constants. Spline data now also uses
1011 different values for different periods
1012
1013 - star: The time-evolution shown in the effective on-time plot now displays
1014 the axis range (if there are no holes it should be similar to the
1015 effective on-time)
1016
1017 - star: Added two new image parameters:
1018 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1019 the three pixels next to the center of gravity and the size
1020 + MNewImagePar.fConcCore: The ratio of the signals of all
1021 pixels inside or touching the ellipse and the size
1022
1023 - ganymed: now stops in requested source isn't found in catalog file
1024
1025 - ganymed: Many improvements to the phi-plot in wobble mode:
1026 + with a template the ideal background is displayed
1027 + a possible camera inhomogeneity is taken into account
1028 + the anti theta cut is better supported
1029 + the phi cut is automatically calculated from the theta cut
1030 See the examples in ganymed_wobble.rc for more details.
1031
1032 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1033 times the bin-width instead of the absolute energy
1034
1035 - ganymed: New cuts for on/off and wobble mode
1036
1037 - ganymed: The smearing of the False Source plot has been increased
1038 to 0.06
1039
1040 - ganymed: The starguider calibration can now be changed from the
1041 resource file.
1042 See the examples in ganymed*.rc for more details.
1043
1044 - ganymed: added a new option for on-/off-observations
1045 MJCut.RandomSourcePosition
1046 If switched on the distribution of observation time of the source
1047 position in the camera is calculated from the on-data and randomly
1048 applied with this distrbution to the off-data.
1049
1050 - ganymed: by skipping some obsolete calles in the eventloop the
1051 first and second loop could be accelerated by ~20%
1052
1053 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1054 position in the off-data randomly according to its distribution in the
1055 on-data.
1056
1057
1058
1059 *** Version 0.9.4.3 (2006/02/13)
1060
1061 - general: Fixed a bug in most of the programs which prevented the
1062 compile date in the startup message to be displayed
1063
1064 - general: Simplified program calls. The following abbreviations
1065 are now possible:
1066 showlog callisto 55599
1067 showplot signal 55599
1068 star 55599
1069 callisto 55999
1070 ganymed 2
1071 In this cases the corrsponding root-, log-, sequence- or dataset-
1072 filename is automatically compiled using the default datacenter
1073 paths ("/magic/*")
1074
1075 - general: Fixed a long outstanding bug which made axis tick marks
1076 disappear if MDataFormula was used (eg. abs(x))
1077
1078 - general: Updated MMath with new functions to calculate the results of
1079 a exponential, logarithmic and powerlaw fits analytically.
1080
1081 - general: Updated some macros with comments:
1082 + macros/optim/optimdisp.C
1083 + macros/optim/optimenergy.C
1084 + macros/optim/optimwobble.C:
1085
1086 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1087 files) now allows adding a pre-cut like in the optimization. E.g. this
1088 is useful to perform g/h-separation cuts before training the random
1089 forest.
1090
1091 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1092 correctly assigned in the raw data assignement table. A fix to correct
1093 the assignment tabel have been implemented.
1094
1095 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1096 by 90, 180 and 270 deg.
1097
1098 - general: the macro plotdb.C now allows to highlight sequences belonging
1099 to a datset. For more details see the descritions in the macro.
1100
1101 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1102 of the display, it gave wrong results espacially for big sizes.
1103 Now the embedded canvas should always have a ratio width/height=3/2.
1104 The "Size" options have been updated with values fitting the 3/2
1105 size ratio.
1106
1107 - RanForest:
1108 + Updated the random forest classes to support also the
1109 regression method implemented by Thomas H.
1110 + added new tutorial macro how to train the random forest
1111 for energy estimation (macros/optim/rfenergyest.C)
1112 + new classes to train the random forest (still in development)
1113 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1114 + new tutorial macros for random forest training in macros/train
1115 trainenergy.C, traindisp.C, trainseparation.C
1116
1117 - mars: now allows to setup a cut in the resource file mars.rc to choose
1118 the events to be displayed, eg:
1119 Cut.Condition: {0} && {1}
1120 Cut.0: MHillas.fSize>100
1121 Cut.1: MHillas.fSize<900
1122
1123 - merpp: Made aware of the new .rep format 200510250. This includes
1124 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1125 the discriminator thresholds (MCameraTD) and the disciminator
1126 delays (MCameraTD). All of them come with the CC report and are therefor
1127 written to the CC tree.
1128
1129 - callisto: fixed a bug in the calculation of the arrival times in
1130 the Digital Filter. They were all shifted by the same amount
1131 fHiGainFirst. This caused an offset in the order of the position of
1132 the left border of the extraction window in the times calculated
1133 from high-gain and from low-gain. The bug effected only the absolute
1134 arrival times. The bug was there since 30.1.2005.
1135
1136 - callisto: Changed the ExtractionWindow for the pulse position check
1137 such that the camera inhomogeneity becomes as less as possible and
1138 comparable to the pulso position check switched off. More details
1139 on the study will be given at our result web-page.
1140
1141 - ganymed: ganymed.rc, ganymed_onoff.rc:
1142 changed to new cuts trained with 1ES1218 and Crab-data
1143 for maximum sigma*log10(excess)
1144
1145 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1146 a new option was implemented to estimate Disp (CalcDisp)
1147
1148 - ganymed: Implemented two new options which allow
1149 to overwrite the default path to search for the sequence files
1150 --ins=/magic/sequences
1151 and where to search for the image data
1152 --ind=/magic/data/star
1153
1154 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1155 dx/dy from the resource file by
1156 MSrcPosCorrect.Dx
1157 MSrcPosCorrect.Dy
1158
1159 - ganymed: fixed reading the source catalog. Only as many chars
1160 as the requested source name had were compared (If a source
1161 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1162 were requested it could happen that the coordinates of
1163 "1ES1218" were read) The source coordinates are now printed
1164 in addition to its name to the logging output.
1165
1166 - ganymed: changed the background fit in the case of a ThetaSq function
1167 from a polynomial to a exponential, this should give a big improvement
1168 for on-only analysis'
1169
1170 - ganymed/sponde: Calculation of the error of single size-/energy-
1171 bins now uses Li/Ma (5) instead of LiMa (17)
1172
1173 - sponde: Added a plot E^2*dN/dE
1174
1175 - sponde: The energy estimator plot should now show values like
1176 they are commonly used.
1177
1178 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1179 (a powerlaw with cutoff didn't work before)
1180
1181
1182
1183 *** Version 0.9.4.2 (2005/10/01)
1184
1185 - general: added new tutorial macro macros/tutorials/threshold.C:
1186 how to calculate the threshold
1187
1188 - general: added a new game. Start it from the interpreter with
1189 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1190 and MagicReversi)
1191
1192 - general: neighbor pixels in MGeoms are now sorted clockwise
1193
1194 - merpp: made aware of new format 20050829-0
1195
1196 - callisto: New scale factors from muon analysis, stored in new
1197 resource file resources/calibration.rc
1198
1199 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1200 the eventloop if something went wrong. This is necessary for the
1201 automatic processing
1202
1203 - callisto: Implemented a new treatment for the time information
1204 developed by S.Ruegamer, this should give much better response than
1205 the old very primitive algorithm. This is especially important
1206 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1207 treatment was buggy! As neighbor pixels to interpolate the
1208 arrival times always the pixels 0 to 5 were taken)
1209
1210 - callisto: In addition to the new treatment of arrival times the
1211 decision of the treatment whether a pixel contains shower
1212 information or not is used to improve the signal interpolation
1213 further. Previously interpolated pixels showed a non-zero signal
1214 do the peak searching signal extractors. Having a signal pixel
1215 beside raised the signal above the cleaning level. Thus the
1216 pixel survived cleaning to often but with a too low mean signal.
1217 By replacing empty pixels with a gaus (mean and rms from the
1218 corresponding Area entries in MPedPhotCam) this effect can
1219 be supressed.
1220
1221 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1222 got lost when the events were stored by the calibration... fixed.
1223 (This was no problem for normal image cleaning because the pixel
1224 content was artificially set to 0 not surviving standard cleaning
1225 algorithm)
1226
1227 - callisto: Fixed a bug which caused the random and peak-search pedestal
1228 extracted with an extractor to be exchanged for the first (roughly)
1229 500 events (*Extractor and *ExtractorRndm).
1230 (They were simply exchanged in callisto.cc) This bug might have been
1231 introduced in Mars 0.9.4 when the order of calculation of the two
1232 types of pedestal in callisto got exchanged. The bug only effects
1233 the first seconds of data of each sequence.
1234
1235 - star: Taking the arrival time of Muons into account the calculation
1236 of the parameters could be made independant of the noise
1237 (pedestal rms). The dependance was due to the bias of the peak search
1238 extractor. Now only a ZA dependamcy is left which is not yet fully
1239 understood.
1240
1241 - ganymed: The sequences were still not sorted correctly in any case,
1242 because they were sorted by the full qualified path name. Now they
1243 are sorted by their sequence number.
1244
1245 - ganymed: new values for the spark-event-cut
1246
1247 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1248
1249
1250
1251 *** Version 0.9.4.1 (2005/08/18)
1252
1253 - callisto: fixed some problems with the calibration in case of
1254 inteleaved events. Therefor the final and some intermediate
1255 fits are skipped which would take place on partly filled #
1256 histograms and gave wrong results or failed completely.
1257
1258 - callisto: If the intermediate finalization of the histograms
1259 calculating the mean charge of the calibration signal fails
1260 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1261
1262 - ganymed: Fixed some bugs which caused problems in On-only mode.
1263 Still the false source plot doesn't give reasonable results.
1264
1265
1266
1267 *** Version 0.9.4 (2005/08/05)
1268
1269 - general: Fixed the ZA binning. It did not correctly fit the
1270 MC binning
1271
1272 - general: Added a class to correct for the missfocussing in
1273 April (MSrcPosCorrect)
1274
1275 - general: Random Forest energy estimator should now work properly
1276
1277 - general: MHCamera now displays the profiles in deg instead of mm
1278
1279 - general: MH::SetPalette offers a lot of new palettes
1280
1281 - general: MHillas - the case of CorrXY==0 is now handled properly
1282
1283 - general: implemented the possibility to change the line and
1284 marker style of a sky-grid drawn by MAstroCatalog
1285
1286 - general: Runs in sequences and datasets are now automatically
1287 ordered (it is assumed that the order of their filenames correctly
1288 represents the order of observations) to ensure correct reading
1289 of the subsystem data
1290
1291 - general: Runs cannot be added to a sequence twice anymore. Also
1292 Sequences cannot be added twice anymore to a dataset.
1293
1294 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1295 It gave wrong results by 1./2pi
1296
1297 - showplot: got a new option to start a root interpreter, too
1298
1299 - mars: now displays a rough estimate of Disp and the third moment
1300
1301 - mars: now displays the event time MTime if available
1302
1303 - mars: show muon parameters graphically
1304
1305 - mars: now the file to open can be given as commandline
1306 argument
1307
1308 - merpp: Added support for new arehucas version >= 200507190
1309 implementing values for three temperature sensors in the
1310 counting house (MCameraAUX) and the name of the HV settings file
1311 (MCameraHV).
1312
1313 - merrp: Also fixed some problems with wrong versions numbers stated
1314 by arehucas and implemented some fixed for old versions (<200407070)
1315
1316 - callisto: MCalibrationHiLoCam can now be printed from its context
1317 menu, eg in the TBrowser
1318
1319 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1320 - 1.39 (MExtractTimeAndChargeSpline)
1321 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1322 This is important mainly for timing studies.
1323
1324 - callisto: Changed limits in MHCalibrationChargeCalc from
1325 - -100.125 to -98 (fgChargeHiGainFirst)
1326 - 1899.875 to 1902. (fgChargeHiGainLast)
1327 - -100.25 to -99 (fgChargeLoGainFirst)
1328 - 899.75 to 901. (fgChargeLoGainLast)
1329 Introduced new limits:
1330 - fgNumLoGainBlackoutLimit: 0.05
1331 - fgLoGainBlackoutLimit: 3.5
1332 - fgLoGainPickupLimit: 3.5
1333
1334 - callisto: The handling of automatic weights for the digital filter
1335 has been improved. There are now new calibration weights special
1336 for Monte Carlo calibrations.
1337
1338 - callisto: Updated Muon scale with latest results (1% difference
1339 for most data, 5% for Mar/Apr'05)
1340
1341 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1342 was saturated and the blackout-events in the low-gain exceed the
1343 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1344 This excludes those pixels which have a saturating high-gain
1345 channel, but the low-gain switch does not switch often enough
1346 to make the distribution reliable.
1347
1348 - callisto: fix a bug counting the number of saturated events. Up to now,
1349 the number of saturated slices was counted (which is one for a not too
1350 high number), but for some (pathological) pixels, many more slices
1351 saturated and produced wrong limits.
1352
1353 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1354 + MCalibrationRelTimeCam.CheckFitResults: Yes
1355 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1356 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1357 + MCalibrationRelTimeCam.CheckOscillations: Yes
1358
1359 - callisto: introduce max. number of events for intercalibration,
1360 the rest gets skipped. Default: 4096
1361 The calibration causes too many un-reliable pixels if more
1362 than about 5000 events are treated (@500 Hz) because of the
1363 mode hopping of the VCSels. However, in the past, some
1364 calibration runs have been taken (erroneously) with more
1365 than 5000 events, especially the intensity scans where
1366 a good precision is needed.
1367
1368 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1369 photo-electrons for the spline extractor by 1-2% (correctly).
1370
1371 - callisto: The intercalibration is now done using a full f-factor
1372 method instead of a simple update. This makes things slower but
1373 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1374 changes.
1375
1376 - callisto: MPedestalY3 now uses the same extraction range as the data
1377 as calculated by MPedestalY2
1378
1379 - callisto: A check of the fraction of allowed unsuitable (10%) and
1380 unreliable (30%) pixels has been addded when the conversion is
1381 calculated from interleaved events
1382
1383 - star: fixed a bug which caused MEffectiveOnTime containers not to
1384 be written. In the worst case they were skipped almost all, in the
1385 best case they were all ok. It depends on how often the new value
1386 was assigned just with an event which was skipped later by another
1387 task
1388
1389 - star: new histograms MHPointing and MHRate
1390
1391 - star: New tab (Currents) displaying the time evolution of the mean
1392 DC currents
1393
1394 - star: New tab (MeanRms) displaying the time volution of the mean
1395 Pedestal Rms
1396
1397 - star: Output now contains MReportStarguider
1398
1399 - star: Improved muon analysis. Due to the absense of a constant
1400 for the gaus fit for arc width and the fact that the arcwidth
1401 plot was a histogram instead of a profile the resulting psf
1402 became pedestal rms dependant
1403
1404 - ganymed: added new plot (MHPhi) for wobble mode as described in
1405 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1406
1407 - ganymed: corrects now (correctly?) for the misspointing in
1408 May/April 05
1409
1410 - ganymed: Two new default templates for ganymed.rc are avilable:
1411 ganymed_onoff.rc and ganymed_wobble.rc
1412
1413 - ganymed: The first version of MFMagicCuts has been released
1414
1415 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1416
1417 - ganymed, sponde: There are two new options to determin the number
1418 of bins for the signal region (NumBinsSignal) and the number of
1419 total bins (NumBinsTotal) in the MHThetaSq histogram
1420
1421 - ganymed: optimized palettes for MHDisp
1422
1423 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1424 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1425 sqrt(2) to large
1426
1427 - ganymed: The false source plot (MHDisp) is now based on Disp
1428 and a background model determined in the first loop is
1429 subtracted
1430
1431 - ganymed: MFMagicCuts are now available in the cvs. The correct
1432 solution for the disp ambiguity problem is now calculated using
1433 the third moment. The third moment cut therefor is skipped.
1434
1435 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1436 already determined by the third moment along the major axis and
1437 so its actual sign is aligned along the major axis of the shower.
1438
1439 - ganymed: If starguider data is available it is taken into account
1440 when calculating the source position. This is especially important
1441 for wobble data at high zenith angles and culmination data.
1442
1443 - ganymed: If available the starguider data is taken into account as
1444 good as it is possible without a starguider calibration. To switch
1445 it off add
1446 MPointingDevCalc.MaxAbsDev: -1
1447 to your ganymed.rc
1448
1449 - sponde: the zenith angle distribution is now weighted instead of
1450 choosen by default. This gurantees higher statistics in the highest
1451 and lowest energy bins. To switch this behaviour off use...
1452
1453 - sponde: now automatically displays the energy threshold
1454
1455
1456
1457 *** Version 0.9.3 (2005/06/03)
1458
1459 - general: MMcEvt now derived from MMcEvtBasic which should
1460 have no influence on compatibility with older camera files
1461
1462 - general: Implemented a new option to MReadReports which allows
1463 to force reading of the first event of some trees (eg. Drive-tree)
1464 before any other tree.
1465
1466 - general: Made a fix to MPointingPosCalc which assumes that the
1467 run-type is real-data if Process is called before ReInit, such
1468 that also the very first Drive-events in a run are treated
1469 correctly.
1470
1471 - shoplot now displays the filename in the title bar of the window
1472
1473 - merpp: new options: --auto-time-start --auto-time-stop which
1474 allow to cut updating with slow-control at the start- or
1475 (previousle --auto-time only allowed: and) stop-time of
1476 the run stored in the runheader.
1477
1478 - callisto: changed default of fgFallTimeHiGain in
1479 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1480 already set as default in callisto_Dec04Jan05.rc
1481
1482 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1483 now changes the filename for new weights automatically for
1484 cosmics, MC and for different calibration colors.
1485
1486 - callisto: a problem with the order of some code cause the
1487 name of the weights file in MPedestalY2 to be ignored.
1488 Wrongly the calibration_UV weights were used instead
1489 of the cosmics weights set in callisto.rc.
1490
1491 - callisto: should allow ct1 pulser data when the color is
1492 explicitly set also for pretty new runs
1493
1494 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1495 to introduce an additional scale factor (should be around 1)
1496 to adapt for slight deviations in different extractors from
1497 the MC calibration. For MC calibrations the scale factor
1498 is fixed to 1
1499
1500 - callisto: MFCosmics should handle very high signals a bit
1501 more accurate now
1502
1503 - callisto: when calculating the mean pedestal rms for different
1504 pixel sizes or sectors also kUnsuitableEvt is now taken into
1505 account - not only kUnsuitableRun
1506
1507 - callisto: '-raw' option is now the default
1508
1509 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1510 This has the advantage that mean values in the calibration (eg
1511 arrival times) are calculated more accuratly.
1512
1513 - callisto: In the resource file callisto_Dec04Jan05.rc
1514 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1515
1516 - callisto: new Hi-/Lo-Gain intercalibration constants
1517 hilocalib_sp1.root and hilocalib_sp1_mc.root
1518
1519 - callisto: changed default for MJPedestalY2.MaxEvents
1520 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1521
1522 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1523 has changed from 9.0 to 6.0. This is necessary to exclude two very
1524 ringing pixels in September which - when kept - destroy the image
1525 cleaning around them (Markus G.)
1526
1527 - callisto: (!) The Muon analysis of all data taken so far has
1528 suggested that different extractors give slightly different
1529 absolute results after calibration, due to there different
1530 handling of the calibration- and cosmics pulse shape. Although
1531 the over all calibration seems to be a bit to pesimistic (or
1532 the MC seems to be a little bit - 3-5% - too much attenuated).
1533 There for correction factors have been introduced which correct
1534 the calibration constants by
1535 0.956937799 for Digital Filter (callisto.rc)
1536 and
1537 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1538 calibration. The main advantage is, that both data types can
1539 be easily analysed together and compared to the same MC sample.
1540 The factors are choosen such, that the reference is now a
1541 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1542
1543 - star: fixed a bug which caused the first bin of the histograms
1544 vs time to disapear in PostProcess. This gave wrong results
1545 on the screen. The output and all following programs not
1546 directly accessing the histograms haven't been affected
1547
1548 - star, ganymed: Made sure that always the first Drive-tree event
1549 is read and Processed before the first data event was read.
1550
1551 - ganymed: implemented the possibility to replace the standard
1552 false source plot with a different one. For example: If
1553 you want to use a Disp based FS plot use the resource:
1554 NameHistFS: MHDisp
1555 For details about the requirements of these plots look
1556 at the corresponding classes
1557
1558 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1559 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1560 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1561 case MAlphaFitter is setup correctly. For On-Only optimization
1562 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1563 RunOn() instead of Run(). For energy estimation MJOptimize
1564 has been replaced by MJOptimizeEnergy
1565
1566 - sponde: The input MC spectrum can now be weighted to fake a
1567 different spectrum. This is done via MMcSpectrumWeight. For
1568 more details see the class description and sponde.rc
1569
1570 - sponde: The paremeter comparsion plots are not scaled by
1571 their entries anymore. Instead the MC plot is scaled by using
1572 the result spectrum of the analysis. If the input MC spectrum
1573 and the result spectrum has different slopes the absolut
1574 normalization is normally wrong.
1575
1576
1577
1578 *** Version 0.9.2 (2005/05/20)
1579
1580 - general: Changed the default paths for calibrated data and image
1581 files. (The implemented access to these files doesn't yet exist)
1582
1583 - general: support for MRunIter has been removed from the job classes
1584 (use the setter functions of MSeqeunce instead)
1585
1586 - general: ProcessFile has been renamed to Process in all job classes,
1587 because ProcessFile is missleading
1588
1589 - general: The storage of the palette in MHCamera is now possible
1590
1591 - general: new bits describing unsuitable and unreliable pixels have
1592 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1593 kDeadPedestalRms, kFluctuatingArrivalTimes
1594
1595 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1596 versions newer than V200404070
1597
1598 - general: support for cc file versions newer than V200504130. Added
1599 support for active loads (MCameraActiveLoad) and central pixel
1600 (MCameraCentralPixel)
1601
1602 - general: added new histograms for image parameters versus size
1603 (MHVsSize)
1604
1605 - general: The eventloop now automatically calls PrintStatistics
1606
1607 - Status Display: Improved support for printing:
1608 + A default can now be set in .rootrc (for more details see
1609 MStatusDisplay::PrintPS)
1610 + A print dialog is opened so that printer and command line
1611 can be canged
1612
1613 - showlog: improved such that it handles different verbosity levels
1614 more accurate now. This mean you can suppress output when
1615 using showlog.
1616
1617 - showplot: improved
1618 + The new graphics formats have been implemented
1619 (pdf, svg, png, jpg and xpm)
1620 + Implemented an interface for printing. Because you can change
1621 the printing command from the command line you can use all
1622 the nice postscript tool. To print a booklet for example call:
1623 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1624 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1625 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1626
1627 - callisto: fixed a bug in the recognition of the calibration bit
1628 pattern. Concerns only intensity calibration. (The strength of the
1629 intensity has been updated in some cases)
1630
1631 - callisto: add a filter against PIN Diode events when running over
1632 calibration runs since some of the recent calibration runs have
1633 been taken with Pin Diode.
1634
1635 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1636 39943, 44833 in the calibration (MCalibColorSet)
1637
1638 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1639 been set to 1e-18 in callisto_Dec04_Jan05.rc
1640
1641 - callisto: in callisto_Dec04Jan05.rc: set value for
1642 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1643 statistics for the calculation of the mean pulse time
1644 of the cosmisc
1645
1646 - callisto: the charge limit in the calibration has been raised
1647 from 2.5 to 4.5
1648
1649 - callisto: new setup read from callisto.rc
1650 + MCalibCalcFromPast.fNumEventsDump
1651 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1652 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1653
1654 - callisto: MExtractTimeAndChargeSpline extractor:
1655 + The integration ranges were shifted by 0.2 FADC slices to the right.
1656 + unreliable handling of floating point values caused different
1657 results on different platform or with different compiler options:
1658 The new algorithm is numerically exact and more accurate because
1659 it doesn't calculate the integration position by multiple times
1660 adding the step-size (which results in numerical uncertanties
1661 exspecially if multiplied with large numbers)
1662 + A lot of fixes have been introduced which effects integrating the
1663 spline at the edges of the valid range. In this case any memory
1664 was randomly accessed. This behaviour can be tested replacing
1665 all MArrayF by TArrayF which perform a range check (but of course
1666 they are a lot slower)
1667 ! No result obtained with the Spline before can be trusted! Due to
1668 random memory access it might by completely random!
1669
1670 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1671 + extraction range in the high gain to 4.
1672 + weights file to cosmics_weights46.dat
1673
1674 - callisto:
1675 + introduce the check for fluctuating arrival times.
1676 + set charge limit to from 2.5 to 4.5
1677 + introduce asymmetric exclusion due to "deviating number of phes":
1678 Default: -9.0 +4.5
1679 + make deviating number of phes unsuitable (see David's findings).
1680
1681 - callisto: fixed the display of unsuitable pixels. The old change
1682 to a real profile in MHCamera broke it.
1683
1684 - callisto: The cosmics filter is used in MJCalibration now
1685 independant of the pulser color (formaly it was used only for
1686 CT1-pulser data). The threshold of number of max empty pixels
1687 has been raised from 2% to 5% in MJCalibration. The maximum
1688 fraction of rejected event is 50% otherwise the calibration has
1689 failed. The filter now ignores unsuitable pixels.
1690 Setup the filter from callisto.rc using "ContCosmics"
1691 (see MFCosmics::ReadEnv)
1692
1693 - callisto: changed default for fgOffsetFromLogain back
1694 from -2.8 to -1.8 in digital filter.
1695
1696 - callisto: for the common extractors
1697 + MExtractFixedWindow
1698 * MExtractTimeAndChargeSlidingWindow
1699 * MExtractTimeAndChargeSpline
1700 * MExtractTimeAndChargeDigitalFilter
1701 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1702 and fResolutionPerPheLoGain
1703
1704 - callisto: Updated the hi-/lo-gain intercalibration constants
1705 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1706 hilocalib_df6.root
1707
1708 - callisto: The default lo-gain extraction window for the
1709 MExtractTimeAndChargeSlidingWindow extractor has been increased
1710 from 6 to 8 to take the stretch of the pusle into account
1711
1712 - callisto (!!!): fixed an important bug in the setting of the
1713 incoming pedestal pointer to the signal extractor extracting
1714 pedestals. This bug caused the pedestals not to be subtracted
1715 correctly in the calibration afterwards. The effect was about 10%
1716 too high conversion factors for the digital filter and the spline
1717 and more than 40% for the sliding window.
1718 The bug existed since end of February! (Markus G.)
1719
1720 - star: added muon support to star. A new tab "MHMuonPar" is
1721 displayed. The lower right plot is an estimate of the point spread
1722 function. A reference value is displayed. To get the real PSF
1723 you must compare with MC. The setup for the muon analysis
1724 is done in star.rc. More informations can be found in
1725 MHSingleMuon and MHCalibParCalc
1726
1727 - star: The weather data is now displayed in star
1728
1729 - star: MEventRateCalc handles the calculation of the event rate more
1730 accurate now in case of the start of a new run inside a sequence
1731
1732 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1733 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1734 changed only minimally
1735
1736 - ganymed: (MJCut and MJOptimize) now displayes the number of
1737 excess events versus size. The energy estimation is done in
1738 MJSpectrum (sponde)
1739
1740 - ganymed: got support for using other variables than Alpha, eg. Theta.
1741 Therefor you need a class deriving from MHAlpha which supports
1742 this variable (one is already existing: MHTheta, which is now the
1743 default in ganymed). It is setup through ganymed.rc
1744
1745 - added a full featured spectrum program (sponde) which reads
1746 ganymed output and monte carlos and compiles a spectrum
1747
1748
1749
1750 *** Version 0.9.1 (2005/04/14)
1751
1752 - Fix bug on the arrival time reconstruction when using Digital
1753 Filter (in some marginal cases (10%) times were reconstructed shifted
1754 by 0.2 slices)
1755
1756 - all executables now return 2 where in previous versions -1 has
1757 been returned (gave problems with shell-scripts)
1758
1759 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1760 also done with a intercalibration input file
1761
1762 - a bug in the time fine adjustment of the digital filter has been fixed
1763
1764 - a lot of small fixes to calling TPad::Divide with a margin==0
1765
1766 - MStatusDisplay now shows the memory usage
1767
1768 - added a memory leak statistic after the eventloop
1769
1770 - MHadronness replaced by MParameterD
1771
1772 - MEnergyEst replaced by MParameterD
1773
1774 - wobble mode can now be switched on from the data-set
1775
1776 - switched on bad pixel detection for a pedestal level
1777 which is more than 5 times the variance
1778
1779 - Fixed default paths to be correct for the new data center
1780
1781 - Fixed handling of drive data. The pointing position in now
1782 copied to MPointingPos inside star for real and MC events
1783
1784 - made sure, that the sequences in a dataset are sorted by
1785 their number to ensure the correct synchronization
1786
1787 - added all resource files necessary to handle spline extraction
1788 of signal for the late 2004 and the early 2005 data
1789
1790 - update the reference lines for the december data
1791
1792 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1793 This is important for the Dec. and Jan. data where the calibration
1794 pulse position changes much.
1795
1796 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1797 filter. This corrects only an defective extraction of the MC at
1798 low-gain signals lower than 90 phes.
1799
1800 - fixed some slowdown in calibrating data with interleaved events from
1801 Jan and Dec. As a workaround made the pretty palette the default.
1802 The inverse Deep Blue Sea has a bug which slows down long calibration
1803 runs a lot.
1804
1805 - implemented new values from new starguider report as defined
1806 in TDAS00-07 V7.1 (eg SkyBrighness)
1807
1808 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1809 in starguider report (If you merpp the same reports with this version
1810 you'll get the correct units (arcmin) but a different result
1811 than with old versions (wrong units))
1812
1813 - Now the status display can also write PNG, JPEG and XPM (other file
1814 formats are still unsupported by root)
1815
1816 - added a lot of scripts and macros in directory datacenter used
1817 for automatic processing
1818
1819
1820
1821 *** Version 0.9 (2005/03/23)
1822
1823 - Calibration is now done autmatically into photo-electrons like
1824 decided by the Collaboration Board
1825
1826 - Reference lines in the display can be read from resource file
1827
1828 - Interlaced calibration events can be handled by callisto
1829
1830 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1831 and applied in callisto.
1832
1833 - class MJCalibTest can be called by callisto
1834
1835 - callisto can now run with three data types: rawdata, rootdata, MC
1836
1837 - added two classes mreport/MReportStarguider.cc and
1838 mreport/MReportStarguider.h for implementing starguider-data
1839
1840 - the output of merpp-update now contains starguider information:
1841 MReportStarguider and MTimeStarguider
1842
1843 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1844 values were lower than they should. This was more visible for high
1845 energy (Size) events.
1846
1847 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1848
1849 - added a new loop to callisto to support the correct extraction of
1850 the pedestal and pedestal rms through the signal extractor
1851
1852 - added class to perform fourier tranformation of a hexagonal structure
1853 (MHexagonalFT)
1854
1855 - added class to perform fourier tranformation of a hexagonal structure
1856 in a tasklist (MHexagonalFTCalc) example: hft.C
1857
1858 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1859 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1860 small pixels, example: extendcam.C
1861
1862 - added possibility to write data to memory (TTree) using MWriteRootFile
1863
1864 - added possibility to read a TTree stored only in memory by MReadTree
1865
1866 - new classes to deal with the interleaved calibration events:
1867 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1868
1869 - implemented filters to callisto to skip calibration events
1870
1871 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1872 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1873 the slices by statistics
1874 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1875 signal extractor without randomization
1876 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1877 with the signal extractor with randomization (extraction window is
1878 randomly fixed)
1879 The three kind of pedestal is not yet implemented (for speed reasons) as
1880 long as nobody really needs it:
1881 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1882 extracted with the signal extractor with randomization
1883
1884 - callisto now finds the pulse position in the data automatically
1885
1886 - implemented data reduction in calibrated data by reducing the precision
1887 of the stored floating point values (pedestal, rms and signal) to
1888 roughly 0.5%
1889
1890 - fixed showplot to make file format conversion (eg. converting a
1891 status display stored in a root file into a postscript file) in
1892 batch mode possible:
1893 showplot -b --save-as-ps[=outfile.ps] infile.root
1894
1895 - Allow class names as part of filter rules, eg
1896 (MFSupercuts) && (MHillas.fSize>100)
1897
1898 - fixed a lot of stuff to allow all programs to process MonteCarlo
1899 camera files.
1900
1901 - enhanced possibility to debug reading of resource file
1902
1903 - MDataChain should handle priorities of operator more
1904 accurate now
1905
1906 - completely revised the container in which the signal is stored
1907 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1908 * the new implementation is faster and
1909 * needs less storage space
1910
1911 - FIRST version which can process Monte Carlos through the
1912 whole chain of programs (callisto, star, etc)
1913
1914 - implemented new image parameters for the border length of
1915 the shower image (MNewImagePar2)
1916
1917 - implemented wobble-mode in ganymed
1918
1919 - new class (MJOptimize) taking care of all optimization processes
1920
1921
1922
1923 *** Version 0.8.6 (2004/10/05)
1924
1925 - New combined signal and time extractor
1926 MExtractTimeAndChargeDigitalFilter
1927
1928 - The Report for the trigger section in the CC run summary has been
1929 updated, and now the IPRs (Individual Pixel Rates) are available.
1930
1931 - new macros for database interaction: filldotrun.C, filldotrbk.C
1932
1933 - added new program which can convert colored output which was redirected
1934 into a file back into colored text (for example to display it with
1935 more): showlog
1936
1937 - added new program to display an MStatusArray of plots (stored with
1938 MStatusDisplay) from a file: showplot
1939
1940 - Added support for Sequences (MSequence). Sequences are blocks of run
1941 files containing the same calibration and belonging to the same
1942 source
1943
1944 - Added a new task (MTaskEnv) which can be used in setup files to switch
1945 between different tasks (for example to choose a signal extractor)
1946
1947 - Implemented automatic file splitting in MWriteRootFile
1948
1949 - After image cleaning an island index is assigned to all used pixels.
1950 The index corresponds to the order of the islands in size.
1951
1952 - added a cleaning which takes signal height _and_ arrival time into
1953 account: probability cleaning (for more details see MImgCleanStd)
1954
1955 - added a cleaning which takes takes the absolute number of photons
1956 times the area ratio as cleaning level
1957 (for more details see MImgCleanStd)
1958
1959 - Changed calculation of image parameters such, that it can be done
1960 for all used pixels or the pixels with a defined island index only
1961
1962 - implemented new image parameters displaying the number of islands,
1963 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1964
1965 - event display in executable changed to support also calibrated files
1966 (done with MJCalibrateSignal)
1967
1968 - added program doing the calibration and the signal extraction
1969 and signal calibration: callisto Most part of the setup is done
1970 by a resource file: callisto.rc
1971
1972 - implemented support for pixels with negative IDs (Raw file format
1973 version 4)
1974
1975 - implemented an new option in merpp (--auto-time) to get the time
1976 range for cc and/or caco data from the run header of the raw data
1977
1978 - New star-program (star and MJStar). Taking calibrated data from
1979 callisto/MJCalibrateSignal as input. The setup is done through
1980 a resource file: star.rc
1981
1982 - Added possibility to setup the eventloop in the mars-executable
1983 Camera Display by a resource file: mars.rc
1984
1985 - The the mars-executable Camera Display can now also read
1986 calibrated data files written by callisto/MJCalibrateSignal
1987
1988 - Added a new class which can calculate the source position in
1989 the camera from a pointing model known to be correct and
1990 the pointing model used for observations (MSrcPosFromModel)
1991
1992 - added a new version of the class calculating the effective on-time
1993 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1994 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1995 MHTimeDiffTheta.
1996
1997 - added the possibility to count how often a signal is above (or
1998 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1999 can replace MHTriggerLvl0)
2000
2001 - added ore convinient ways to set the axis-titles of your histograms
2002 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2003 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2004
2005
2006
2007 *** Version 0.8.5 (2004/08/06)
2008
2009 - new Signal Extractors: MExtractFixedWindowSpline
2010 and MExtractAmplitudeSpline
2011
2012 - implementes interleave in merpp to be able to merpp parts of a file
2013
2014 - implemented force-functionality to merpp
2015
2016 - star display to display star catalogs (MAstroCatalog)
2017
2018 - star display to 'mirror' stars to the camera (MAstroCamera)
2019
2020 - implemented a new cleaning option which allows cleaning scaled with
2021 the real ratio of the rms depending on the pixel size, not only the
2022 square root of the pixelsize (MImgCleanStd, MCameraData)
2023
2024 - removed obsolete MBlind* classes
2025
2026 - Signal extractor taking the AB flag into account implemented (this makes
2027 an odd number of slices for signal extraction possible
2028 (MExtractSignalABcorr)
2029
2030 - implemented a class extracting the pedestal from the raw-data (events)
2031 itself using empty lo-gain (MpedCalcFromLoGain)
2032
2033 - Added mean values to MPedPhotCam
2034
2035 - Added Makefile for Darwin (this OS is NOT officially supported!)
2036
2037
2038
2039 *** Version 0.8.4 (2004/04/19)
2040
2041 - new fast arrival time extractor using cubic splines:
2042 MExtractTimeFastSpline
2043
2044 - implementes multi-argument support in MDataChain
2045 ("pow(a, b)")
2046
2047 - implemented double reference support in MDataChain
2048 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2049
2050 - added support in MF for expressiond like
2051 "MHillas.fWidth<2*<MHillas.fLength"
2052
2053 - MDataChain is now able to support variables like [0], [1], ...
2054 which can be used in fit functions as parameters. The interface
2055 is implemented through the new virtual function
2056 MParContainer::SetVariables
2057
2058 - added new class MArrivalTimeCam/MArrivalTimePix:
2059 Storage containers to hold the ArrivalTime of the camera/pixel
2060
2061 - added new classes for the calibration of relative arrival times:
2062 MCalibrationRelTimePix and MCalibrationRelTimeCam
2063
2064 - added new classes to extract the signal of the blind pixel and the
2065 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2066
2067 - added new classes for the bad-pixels treatment (MBadPixels*)
2068 which are more powerfull than the old ones (MBlindPixel*)
2069 and will replace them.
2070
2071 - added filter against cosmics: MFCosmics
2072
2073 - added new class MArrivalTimeCalc2:
2074 Calculates the arrival time as the signal weighted mean of the time
2075 slices in the maximum window
2076
2077 - added a new macro call pointspreadfucntion.C that fits with a 2D
2078 gaussian the DC spot for an star. It gives you the RMS of
2079 the PSF and the center of the star, very useful for misspointing
2080 studies.
2081
2082 - added support for multi-telescope camera files. Added classes
2083 MStereoCalc and MStereoPar, classes to calculate and store shower
2084 parameters calculated from the data of two telescopes, for the MC
2085 studies regarding the MAGIC clone.
2086
2087 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2088 MC data calibrated in photons instead of ADC counts.
2089
2090 - added three macros to show the calibration and analysis chain of
2091 MC data. The macro starmc.C does both calibration and analysis, producing
2092 an output containing Hillas parameters for each event. The macro
2093 mccalibrate.C does just the calibration and writes out a file containing
2094 pixel information in photons instead of FADC data. The macro starmc2.C
2095 reads in such a file and produces an output with Hillas parameters.
2096
2097 - added MPedPhotCalc to compute pedestals in units of photons, see
2098 macro pedphotcalc.C
2099
2100 - added all class to perform the calibration, see macro calibration.C
2101
2102 - added class MFFT to perform Fast Fourier Transforms
2103
2104 - added class MSimulatedAnnealing to perform simulated annealing
2105 minimizations
2106
2107 - added new macro bootcampstandardanalysis.C which holds the skeleton
2108 of the analysis chain discussed in the december bootcamp.
2109
2110 - added support for DAQ raw data file format V2
2111
2112 - implemented an arbitrary time stamp for the events from raw-data
2113 files with file version<3. It is calculated from the run number,
2114 the date of start and the FADC clock tick from the first module
2115
2116 - implemented the correct decoding of the event time-stamp
2117 coming from the DAQ for raw-data files with file-version>2
2118
2119 - added a new classes storing the pedestals in units of photons:
2120 MPedPhotPix, MPedPhotCam
2121
2122 - added support for DC current files from the camera control
2123
2124 - added support for start- and stop-time when merpping report files
2125
2126 - added MReportCC storing the weather data from the CC-REPORT
2127
2128 - added class to fill trainings and test matrices (MTFillMatrix)
2129
2130 - added a filter performing a software trigger (MFSoftwareTrigger)
2131
2132 - Added classes to perform parts of the standard analysis (Jobs):
2133 + MJPedestals
2134 + MJCalibration
2135 + MJExtractSignal
2136 Note: All of them are preliminary!
2137
2138 - Added Iterator to iterate over files giving only the run-number
2139
2140 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2141 the evolution of a sector vs time
2142
2143
2144
2145 *** Version 0.8.3 (2003/12/05)
2146
2147 - adapted Random Forest classes to allow the use with MC
2148 multi-telescope files which can be produced with the coming
2149 camera version 0.7.
2150
2151 - added classes to read and interprete central control report files
2152 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2153
2154 - enhanced merpp (the executable) to support .raw and .rep files.
2155
2156 - added classes for light calibration (MCalibration* and
2157 MHCalibration*) by Markus Gaug. Further work has to be and will
2158 be done soon.
2159
2160 - Added a preliminary 'synchronizer' (MReadReports) which will
2161 replace MReadMarsFile as soon as it is finished.
2162
2163 - Added a tutorial macro demonstrating how report files are merpped
2164 and how they can be read from the root file in the correct order
2165 of time (readrep.C)
2166
2167 - Added a generalized histogram (similar to MH3) called MVsTime
2168 which allows to plot variables (or rules - MDataChain - of
2169 variables) vs time. For an example have a look at tempvstime.C.
2170
2171 - Changed the name of the event trees:
2172 + Events --> Events
2173 + PedEvents --> Pedestals
2174 + CalEvents --> Calibration
2175
2176 - changed name of MTime in the event trees from MRawEvtTime to MTime
2177
2178 - added displaying the sector indices to the mars event display
2179
2180 - Magic Online Analysis (MOnA) implemented in a first version
2181 (see mona.cc, MOnlineDump and MOnlineDisplay)
2182
2183 - added classes to calculate event rate
2184 (preliminary: MEventRateCalc, MEventRate)
2185
2186 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2187
2188 - added classes dealing with the telescope pointing position (MPointing*)
2189
2190 - implemented the 'final' Mars time stamp based on some experiences with
2191 the new 'Synchonizer'
2192
2193
2194
2195 *** Version 0.8.2 (2003/11/10)
2196
2197 - accelerated standard analysis by a factor of 6-8 ...
2198 + doing precalculations in MGeomCam for the pixel area ratio
2199 + creating a look up table for the single pixels in MCerPhotEvt
2200
2201 - added task to calculates weights in case you want to 'change'
2202 the energy spectrum of a monte carlo file
2203 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2204
2205 - added a new executable star which implements the
2206 star.C macro as precompiled executable. Currently a flexible
2207 setup is not possible, but a 'input card' setup will follow.
2208
2209 - Starting to implement Multi-Telescope-Support based on the
2210 upcomming camera version 0.7. The base for a general support
2211 is implemented and the star-functionality is proven to work.
2212
2213 - Replaced Event-Display in and Camera-Display in the Mars GUI
2214 executable by a more convinient display base on MStatusDisplay.
2215
2216 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2217
2218
2219
2220 *** Version 0.8.1 (2003/10/20)
2221
2222 - added signal subtraction for pure on data by means of fitting
2223 the background in the off region or by performing a combined
2224 signal/background fit. Provides necessary histograms for
2225 obtaining energy spectra and a light curve.
2226
2227 - added classes to perform and study the selection of the
2228 2nd Level Trigger on MC data (example in triglvl2.C macro)
2229
2230 - added pedestal calculation
2231
2232 - implemented "democratic cleaning" (tail cut value proportional
2233 to pixel area) according to Wolfgang's suggestion.
2234
2235 - added Sigmabar treatment (calculation and basic histogramming)
2236
2237 - added basic routines to apply padding
2238
2239 - added first implementation of MARS-based source visibility plotter
2240 (needs to be linked against slalib, preliminary version)
2241
2242 - enhanced functionality of data chains: random numbers, conversion
2243 functions and access to MHMatrix objects
2244
2245 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2246 numbers under certain circumstances (runs with 0 events included)
2247
2248 - fixed a bug in the general filter MF (didn't work on some systems
2249 at all)
2250
2251 - fixed a bug in chaining files, which caused the analysis to crash or
2252 ignore files
2253
2254 - implemented more geometry classes describing the parameters used
2255 to simulate the PMT camera
2256
2257 - added new Monte Carlo classes containing the setup of the different
2258 programs in the MC chain.
2259
2260 - added a (preliminary) general task to evaluate chi-square of a given
2261 parameter in an eventloop.
2262
2263 - first implementation of a container describing the observatory
2264 location (Long, Lat, etc)
2265
2266 - added Random Forest - method for g/h-separation
2267
2268 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2269 (this means, that it is compiling, but not yet fully tested)
2270
2271 - added a new status display which can show the present status
2272 of histograms while an eventloop is running (MStatusDisplay,
2273 an example can be found at status.C)
2274
2275 - reorganized directories:
2276 classes describing the image --> mimage
2277 classes containing Monte Carlo Histograms --> mhistmc
2278 classes for Random Forest method --> mranforest
2279
2280 - added (event-)weights to fill histograms
2281
2282 - colors in logging output to screen
2283
2284 - changes to the Image Parameter declaration:
2285 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2286 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2287 + MHillasExt now derives from MParContainer instead of MHillas
2288 --> Files written with the old definition are more or less unreadable
2289
2290 - reading of reflector files
2291
2292 - display data from reflector files in the camera
2293
2294 - implemented currents (and display them in the camera)
2295
2296 - logarithmic scale in camera
2297
2298 - added class to iterate through directory contents (MDirIter)
2299
2300
2301
2302 *** Version 0.8 (2002/11/18)
2303
2304 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2305
2306 - corrected 48(!) wrong entries in the Next Neighbor table of the
2307 Magic Camera (all in the inner part of the outer ring, mostly
2308 missing a single NN)
2309
2310 - Fixed a bug in the table describing the Next Neighbours of the
2311 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2312 have any neighbour)
2313
2314 - changed trigrate.C: now it calculates the pure NSB triggers from
2315 a camera file (generated with no showers), so there is no need
2316 to introduce them by hand in the BgR array (for more details
2317 please ask Abelardo)
2318
2319 - added MHHadronness (and MHadronness) as a general facility to evaluate
2320 the quality of a gamma-hadron seperation method
2321
2322 - changed MWriteAsciiFile to accept rules (MDataChain)
2323
2324 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2325 must be replaced by calles to MWriteAsciiFile::AddColumn and
2326 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2327 changed.
2328
2329 - Implemented generalized event-matrices (one row per event)
2330 (MHMatrix)
2331
2332 - implemented the one dimensional composite probabilities
2333 (MHCompProb, MCompProbCalc, comprob.C)
2334
2335 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2336 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2337
2338 - Added a camera display displaying the pixel numbers to the
2339 event display gui.
2340
2341 - Added Monte Carlo Informations to event display gui
2342
2343 - Changed the camera display to display the pixel numbering
2344
2345 - Added three buttons to the camera display to change the palette
2346
2347 - Added the number of used and core pixels after image cleaning
2348 to MHillas
2349
2350 - Changed the algorithm used in MHillas according to TDAS 02-03
2351
2352 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2353
2354 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2355
2356 - Added fCosDeltaAlpha to MHillasSrc
2357
2358 - The numbers of photons used to calculate fConc and fConc1 in
2359 MHillasExt are now scaled with the pixel size, so that one get
2360 a four times smaller value for the bigger pixels in the outer ring.
2361
2362 - added new task to smooth the camera contents (MCameraSmooth)
2363
2364 - added possibility to use interpolated pixel values for blind pixels
2365 instead of removing it completely from the analysis
2366
2367 - Implemented the possibility to save the whole eventloop with
2368 its setup to a file. This information can be read and from
2369 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2370 and MEvtLoop::MakeMacro. If you find something not working, please
2371 report - this stuff is still in a beta phase.
2372
2373 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2374 file having crab starfield, but also for all following files - fixed
2375
2376 - MTaskList::PrintStatistics can now be instructud to print also the
2377 title, too: use PrintStatistics(0, kTRUE)
2378
2379 - Changed the image cleaning so that pixels with to many 'used'
2380 neighbors are left used (to get rid of 'holes' in events)
2381
2382 - Introduced more output to the camera displays
2383
2384 - Added an array of histograms (eg one hist per run), MHArray
2385
2386 - Added a _preliminary_ version of the reader for CT1 PreProc files
2387 (MCT1ReadPreProc)
2388
2389 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2390 (thanks to Raquel)
2391
2392 - added the first energy estimator (MEnergyEstParam, estimate.C,
2393 estfit.C) using a parametrization
2394
2395 - Added some new Monte Carlo paremeter containers used to store
2396 setup information from the MC chain (MMcConfigRunHeader,
2397 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2398
2399
2400
2401 *** Version 0.7 (2002/04/30)
2402
2403 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2404 the pedestal mean value was saved incorrectly. For files from
2405 this versions we substract 0.5 from the pedestal mean.
2406 WARNING: This may effect your results, so don't wonder...
2407
2408 - First implementation of an algorithm using only triggered events
2409 for the collection area calculation
2410
2411 - Ascii Output can now also be used for parameter containers which
2412 doesn't overload MParCointainer::AsciiWrite
2413
2414 - The Ascii Output is now also capable of writing single data members
2415 of one container
2416
2417 - You are now able to change the order of the values written to the
2418 ascii file
2419
2420 - You can now specify a conversion factor for each data member written
2421 to an ascii file. This may be usefull to change the units of the
2422 data member (eg. degrees instead of millimeters in case of the
2423 hillas parameters)
2424
2425 - Replaced old MHillas by a new structure which allows you to extend
2426 the parameters stored in MHillas very easily:
2427 see MHillas and MHillasExt
2428
2429 - Added classes to handle source dependancy of image parameters:
2430 see MHillasSrc
2431
2432 - Added container (MBinning) to have a standard input for the binning
2433 in different histograms (eg. the Energy bins should be the same in
2434 all histograms)
2435
2436 - Changed Hillas histograms from mm to deg
2437
2438 - Added the flexible binning to the hillas histograms
2439
2440 - Added a filter for the alpha parameter (MFAlpha)
2441
2442 - It is now possible to write single data members of a class object to
2443 an output stream instead of the whole container only
2444
2445 - Added a generalized filter for a data member:
2446 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2447
2448 - Added a generalized Filter parser for more difficult filter rules
2449 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2450
2451 - Added new Monte Carlo histograms:
2452 MHMcEnergyImpact and MHMcEfficiency
2453
2454 - Added many new histograms needed for the flux calculation.
2455
2456 - Added a generalized histograms which can fill and show up to three
2457 data members in either a one-, two- or three-dimensional histogram, eg:
2458 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2459
2460 - Added:
2461 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2462 * calculation of <Theta> as a function of time (MHThetabarTime)
2463 they are needed in the flux calculation in
2464 order to select for a given bin in Theta (or time) the appropriate
2465 effective collection area, which is assumed to be given as a function
2466 of Theta and the true energy
2467
2468 - Added calculation of the migration matrix in the energy
2469 (MHMcEnergyMigration):
2470 the migration matrix describes the migration from the true (E_true)
2471 to the estimated energy (E_est); it is needed to determine the
2472 distribution of E_true from the measured distribution of E_est
2473 by unfolding
2474
2475 - changed the color palette in the camera display to DeapSea.
2476
2477
2478
2479 *** Version 0.6 (2002/01/15)
2480
2481 - Introduce the option of disable pixels (MBlindPixels and
2482 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2483 able to deal with Star Field NSB.
2484
2485 - Fixed a bug in the pedestals substraction
2486
2487 - Introduced verbosity levels
2488
2489 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2490
2491 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2492 work correctly (thanks to Abelardo)
2493
2494 - Introduced correct treatment of the diffuse Night Sky Background
2495 and NSB (MMcPedestalNSB)
2496
2497 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2498
2499 - Introduced MMcRunHeaders which contains monte carlo run informations
2500
2501 - Added a 'Print'-Task (MPrint) which calls the Print function
2502 of a parameter container for each event
2503
2504 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2505
2506 - changes to be more efficient with root 3.02/06
2507
2508 - root 3.02/06 fixes:
2509 + the memory leak when reading MRawEvtData
2510 + loosing more time than necessary to update the progress bar
2511
2512 - MWriteAsciiFile is now capable of writing more than one container
2513 in a line. For example: To be able to write Monte Carlo and
2514 Hillas values (energy and alpha) in one line.
2515
2516
2517
2518 *** Version 0.5 (2001/11/06)
2519
2520 - Added new GUI functionality (Analysis)
2521
2522 - Added a camera display to be able to display events in the camera
2523 together with the calculated hillas ellipse
2524
2525 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2526 object at any state of the analysis, so that the output are several
2527 states
2528
2529 - Fixed a bug in the collection area error calculation
2530 (Thanks to Ciro and Abelardo)
2531
2532 - Fixed a bug which causes merpp to crash in some environments
2533
2534 - Implemented auto enabling scheme for Branches to speed up reading
2535 a lot (see MReadTree and MTask)
2536
2537 - Fixed a bug in the Histogram classes which caused histograms to
2538 be written to a file by MWriteRootFile without request
2539
2540 - changed the object I/O from the old stylish root I/O to the new
2541 'auto evolution scheme' This was done only for classes which are not
2542 yet used in Monte Carlo files, so that these files are still readable.
2543
2544 - Added support for a progress bar in MEvtLoop and MReadTree
2545 (see the Analysis Window in Mars for an example)
2546
2547 - Fixed a bug in the package creation which disturbed the conversion
2548 between a mars version unpacked from a tar file and the repository.
2549
2550 - Changed the code to writer merpped (converted into root format)
2551 raw files, to get faster (around 10%)
2552
2553
2554
2555 *** Version 0.4 (2001/09/20)
2556
2557 - This release is made to compile on a root version >= 3.00
2558
2559 - Fixed a bug which causes MReadTree to read the first file only
2560
2561 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2562
2563 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2564
2565 - Added a task to write several container to a root file (MWriteRootFile)
2566
2567 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2568
2569 - Added calculation of the collection area (MMcCollectionAreaCalc)
2570
2571 - fixed some bugs in the Hillas calculation
2572
2573 - added filters to be able to control the task execution dependent on
2574 a parameter (for example: the number of level 1 triggers in a MC-file)
2575
2576
2577
2578 *** Version 0.3 (2001/04/23)
2579
2580 - Many demo macros added
2581
2582 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2583
2584 - Hillas Calculation added
2585
2586 - Standard image cleaning available
2587
2588 - MReadTree is now able to handle more than one file
2589 (Remark: of the same structure)
2590
2591 - Now we are able to display events in a first version of the
2592 Camera event display. To do this we must run the macro
2593 "macros/readCT1.C" to read data from CT1.
2594
2595
2596
2597 *** Version 0.2 (2001/01/24)
2598
2599 - First Implementation of a Gui to read the raw data. Start the
2600 gui with the command mars.
2601
2602
2603
2604 *** Version 0.1 (2000/12/20)
2605
2606 - First official release 0.1
2607
2608 - Changes:
2609
2610 + changed calling style of MRawPixelIterator from do...while to
2611 while-loop
Note: See TracBrowser for help on using the repository browser.