source: trunk/MagicSoft/Mars/NEWS@ 8716

Last change on this file since 8716 was 8716, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 109.9 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Resource file now allow an Include-Resource, i.e. you can
11 read a resource file with default settings, include it in your
12 resource file and overwrite the settings in your file. More than
13 one include file is allowed. Inclusions can be iterative.
14 Include: mydefaults.rc yourdefaults.rc
15 The resources in the first file have higher priority than the
16 second file.
17
18 - general: Now the output files (calib*.root, etc) also contain the
19 resource file (to check it open it in the TBrowser and choose Print()
20 from the context menu)
21
22 - general: Dataset files now allow to overwrite the default path
23 to search for sequence and data files. Note, that the program
24 option and individual resources will overwrite it. For example:
25 SequencePath: /magic/montecarlo/sequences
26 DataPath: /magic/montecarlo/star
27
28 - general: Fixed a problem with variables in MDataPhrase. It seems
29 that only optimdisp (didn't work) was effected.
30
31 - general: Some improvements to the optim and train processing. For
32 example the ststud window now got a proper title.
33
34 - general: The "Status Display: " was removed from the window title
35 within an Eventloop.
36
37 - general: added a new flexible histogram-class (MHn) which can be used
38 for example in testing after optimizations or training to produce
39 user defined histograms.
40
41 - general: The Random Forest now allows attaching an evaluation
42 function which is applied to its output. This allows to train
43 on whatever you like (eg. train on log10(energy), but return
44 energy)
45
46 - general: TheRandom Forest training of energy (trainenergy.c) and
47 disp (traindisp.C) has been improved by more graphical output to
48 judge the result.
49
50 - general: The training of energy (trainenergy.C) has been improved
51 a lot by training on a different quantity than energy. It gives
52 a result which is highly independant of the source spectrum
53 and shows lower bias than all other options.
54
55 - merpp: Merpp can read file format version 9 now. Please realize
56 that for file format version 9 the extraction range is different
57 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
58 the first and last 15 slices have been removed from all MUX data.
59
60 - mars: Similar to writing movies you can now select events which
61 should be displayed in your display. Therefore add the following
62 lines to your mars.rc:
63 MFEvtNumber.FileName: ganymed00223552.root
64 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
65 The input file can be a ganymed-file after (ganymed*.root) or
66 before (ganymed*-summary.root) file. For example to select all events
67 from your on sample after cuts (excluding the ThetaSq cut) use
68 MFEvtNumber.Selector: DataType.fVal>0.5
69 To show all events from your on-sample after quality cuts
70 use the summary file instead.
71
72 - mars: new ways to call mars are implemented. Instead
73 of calling
74 mars filename.root
75 you can now also use
76 mars sequence.txt
77 or
78 mars sequence.txt inputpath
79 or replace sequence.txt by the sequence number if the default
80 sequence file should be used.
81
82 - mars: The default size has been increased
83
84 - mars: There are two new heckboxes which allow to switch off
85 the calculated image parameters
86
87 - callisto: was broken for MCs... fixed.
88
89 - callisto: improved calculation of spline coefficients a lot. This
90 leads to a further improvement of the event rate calibrating MUX
91 data of about 15% (175evt/s instead of 150evt/s)
92
93 - callisto: finally the raw data we read is now real 16bit (with
94 10bit precision) for MUX data and not a stripped 8bit number
95 anymore. Due to scaling of the numbers (without precision loss
96 into an [0-256[ range, the final numbers for pedestal, pedestalrms
97 and extacted signal don't change. However, at all places where
98 raw data is directly accessed (eg. saturation and variation
99 limits in the signal- and pedestal-extraction) the numbers
100 refer still to the data's 16bit range.
101
102 - callisto: The maximum arrival time difference used in the bad
103 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
104 for both, old FADC and MUX-FADC, data.
105
106 - callisto: Be aware that callisto is now calibrating the arrival time
107 in nanoseconds rather than time slices. Also all following tasks
108 have been changed to assume ns units now. If you star data
109 calibrated with an older version it might be necessary to adapt
110 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
111 to obtain optimal results. The plot in the PulsePos tab
112 will now be in ns, too. This might also mean that the Muon
113 analysis in star might not work as perfect as expected as long
114 as old files read in.
115
116 - callisto: The callibration constants of earlier updates got lost
117 somehow. All constants have been updated.
118
119 - star: The PSF is now determined from the profile of the ArcWidth
120 instead of arcwidth/radius. The old way gave to much weight
121 to the bins with low statistics. The reference lines have been
122 updated.
123
124 - star: For speed reasons events suitable for the muon analysis
125 are now also preselected by fConcCOG<0.1 which seems to be a very
126 good preselector for muons.
127
128 - star: is now calculating a new timing parameter the Slope along
129 the major and minor axis of the shower. Therefore a numerical
130 solution of a line-fit is used. To use MHillasExt.fSlopeLong
131 and MHillasExt.fSlopeTrans don't forget to multiply it with
132 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
133
134 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
135 have been removed from MNewImagePar. They have never been good for
136 anything.
137
138 - star: Implemented a new recursive algorithm which is supposed to be
139 faster. Also implemented new cleaning oiptions, which are:
140 + CleanLevel0:
141 The cleaning level above single core pixels can be kept
142 + KeepIsolatedPixels:
143 Define whether single core pixels should be kept
144 + TimeLevel1:
145 The coincidence window in nanoseconds to single used neighbors
146 + TimeLevel2:
147 The coincidence window in nanoseconds to two used neighbors
148 + PostCleanType:
149 MOde in which a time dependent post cleaning should be applied
150 0: No post cleaning
151 1: Require for each used pixels at least one used neighbor
152 within a time-window of CleanLevel1
153 2: Require for each used pixels at least two used neighbor
154 within a time-window of CleanLevel2
155 3: Require first two and second one used neighbor
156 within a time-window of CleanLevel1 and fCleanLevel2
157 respectively
158 + RecoverIsolatedPixels:
159 - recoveres isolated core pixels if they have a used neighbor
160
161 - mars/star: The new default cleaning is:
162 + CleanLevel1: 6.0
163 + CleanLevel2: 3.0
164 + CleanTime1: 1.75
165 + CleanTime2: 1.75
166 + PostCleanType: 3
167
168 - star/ganymed: The old spark-cuts have been replaced by new ones.
169 These new spark cuts have been cross checked with the sequences
170 84720 (before splitter), 101041 (after splitter) and 223539 (new
171 FADCs). In all cases they seperate pretty well, but of course not
172 perfect. Monte Carlos have suggested to tighten the cuts a little
173 bit further at low sizes. This has been done.
174
175 - ganymed: IMPORTANT - The spark cuts have been changed to match
176 all available data more or less well. This might mean that for
177 YOUR data there are still sparks visible.
178 Whenever you do an analysis you have to make sure that NO sparks
179 survive your cuts!
180
181 - ganymed: The old hadronness and size cuts have gotten new indices
182 (10, 11). The old indices 8 and 9 now mean an additional condition
183 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
184 If you want to switch off this cut just move the line far away enough,
185 e.g. by setting c[9] to -500. Please update your ganymed.rc files
186 accordingly!
187 The unit of c[9] is deg. It is the dist at which your cut will
188 cross the slope==0. The unit of the slope is ns/deg. So if
189 you readin files calibrated with an older Mars-version you
190 have to adapt the default value for c[9] to the FADCs:
191 - Multiply by two for the MUX FADCs (run number > 200.000)
192 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
193 - Multiply by 42 for the meaning of life (run number = 200.000)
194
195 - ganymed: The old Cut0 is now called CutQ and is calculated before
196 the source position is caluclated. If you need a quality cut
197 including source dependant data (be very carefull with this!)
198 you have to use Cut0 instead.
199
200 - ganymed: now properly supports three off regions in wobble mode.
201 It will be the default from now on in ganymed_wobble.rc. To change
202 the number of off-regions use
203 NumOffSourcePositions: 1
204 in your ganymed.rc. Also by default no off-theta cut will be done
205 anymore so that you will get a background level higher than the
206 signal level in your ThetaSq plot for ThetaSq>0.2.
207 Due to this be carefull changing the scaling mode away from
208 "None". You will underestimate your signal if your scale interval
209 is not properly set.
210 (Rem: ThetaSqN is no longer needed)
211
212 - ganymed: is now storing the events of all (on- and off-)
213 source positions even in the case of more than one off-source
214 position. This should allow sponde to work properly and the
215 energy estimation is done correctly in all cases (without any
216 "nearest position" trick)
217
218 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
219 with a real pointing model for the starguider is done, calibrated
220 with more than thousand tpoints taken from this date on.
221
222 - ganymed: was broken for Wobble-MCs... fixed.
223
224 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
225 has changed. Note that your old ganymed.rc will be incompatible
226 with the new algorithms! Please check the ganymed.rc files and
227 the class description of MFMagicCuts for more information.
228 It is recommended at the moment to use identical Disp-Parametrizations
229 for on/off- and wobble-mode. If cuts are optimized only
230 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
231 should be optimized. All other values should be kept as they are.
232 If you want to do an anylsis without timing a parameters, you can
233 switch off the timing cuts by seeting parameter 7 to a very small
234 value (eg. -99). To remove the slope parameter from the disp
235 paremtrization set parameter 8 to 0.
236
237 - ganymed: The distribution of observation time versus zenith
238 angle is now shown for off- AND on-data.
239
240 - ganymed: The contents of the source position plot are no longer
241 averaged, thus a lot of (fake) events between the two wobble
242 positions have disappeared.
243
244 - ganymed: There is a new tab "CutT" it contains the VsSize plots
245 with the CutT, whihc is defined in ganymed.rc, applied. It
246 is resonable to use your theta-cut for it, to see if there is
247 something strange (sparks!) in your signal-region.
248
249 - optim, sponde: should now properly support three off-regions.
250 Just produce your ganymed summary files with three off-regions.
251 optim and sponde will automatically get all off events from
252 all off-regions from this file. Please do not forget to
253 set the scaling in optimwobble.C properly:
254 fit.SetScaleUser(1./3);
255 it is not yet read in automatically (will follow soon).
256 In the case of fixed Scale you can also use
257 cuts.SetThetaCut(MFMagicCuts::kOn);
258 no off-cut needed.
259 Be carefull in case of three off-regions when switching on
260 scale mode. Make sure that the scale interval is set correctly.
261
262 - sponde: sponde.rc and sponde_onoff.rc are now idetical
263
264 - sponde: the resouce files have been rewritten with a lot of
265 comments and a well working parametrization for an energy estimator
266
267 - sponde: In the estimated energy versus monte carlo energy plot the
268 contents where exchanged.... fixed.
269
270 - sponde: the so called "accurate"-mode has been removed. It didn't
271 give any improvement in accuracy, only decreased execution speed.
272
273 - sponde: the so called "simple"-mode has been removed. It didn't
274 give any improvement in simple.
275
276 - sponde: the so called "refill"-mode has been removed. It was anyhow
277 not implemented.
278
279 - sponde: now checks whether the theta distribution of your on-data
280 and the theta-distribution of your Monte Carlo sample (after
281 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
282 sample is incomplete) execution is stopped. Execution can be forced
283 using the new option --force-theta. Use this option with care!
284
285 - sponde: Proper collection areas can now be constructed also from
286 Monte Carlo samples generated with different maximum impact
287 parameters. Note that in previous version you neither got
288 a warning or failure, nor was there any obvious sign that the
289 collection area was overestimated due to usage of files with
290 different maximum impact parameters.
291
292 - sponde: If MC files with different lower energy limits are used
293 the primary MC spectrum is artificially completed down to the
294 lowest energy used at all. WARNING: that this gives correct
295 collection areas ONLY if none of the events in this region would
296 survive your cuts at all.
297
298 - sponde: the output file now contains more information about
299 the spectrum (eg. the full 2D collection area histogram).
300 Note, that this information can only be written to the file
301 if it is stored automatically via command line argument.
302 If you only store the status display from within the display
303 the information is lost.
304
305 - sponde: added a new tab "Energy". It shows the residual of the
306 energy (lg(estimated energy)-lg(monte carlo energy)) versus
307 several parameters and it is meant to judge the quality of the
308 energy estimator. In the ideal case the residual is zero
309 and doesn't depend in the variable. In reality even a good estimator
310 can show residuals versus Monte Carlo energy.
311
312 - sponde: added a new tab "EventDist" showing the unweighted real
313 absolute number of events of your sample after cuts. This tells
314 you how many events with this energy you had in your MC files.
315 The same information you get from the error bars of the weighted
316 histograms, but this is less intuitive.
317
318 - sponde: The spectrum plots now show the crab- and 1553-spectrum
319 for comparison. It is not meant to show these curves in
320 publications, they are only for production.
321
322 - sponde: The OriginalMC tree with the events produced by corsika
323 is now processed only once
324
325 - sponde: Finally fixed most annoying bug, which has effected the
326 last bin of the collection area. It was the problem that binnings
327 of root histograms are from 1 to n (included) but there was a C-like
328 loop in sponde from 0 to n (excluded). Now the loop also includes
329 correctly under- and overflow-bins. The worse thing with this is,
330 that for the events in the highest bin not only the bin-content
331 was wrong, but also the weights applied to these events, which could
332 in pricipal effect also other parts of the distribution (eg. due
333 to energy estimation). Fortunately it effected only a few events
334 in most cases.
335
336
337
338 *** Version 1.2 (2007/05/14)
339
340 - database: The database now has two new values Unsuitable50 and
341 Unsuitable01. They express the number of pixels which are
342 unsuitable for more than 50%, respectively more than 1%, of
343 all calibrated event. It is a more accurate number than the
344 previously used numbers, because they only take the first
345 calibration (ignoring the interleaved calibrations) into account.
346
347 - database: The database now has two other new values UnsuitableMax and
348 DeadMax. They express the maximum number of pixels which were
349 unsuitable, respectively dead, during the sequence. Because
350 of high pedestal rms (cars passing) a few events with very high
351 numbers of unsuitable pixels can happen. Not to suffer from this
352 effect we don't take the highest 0.1% of the numbers into account.
353
354 - general: fixed a bug which caused callisto and star to stop working
355 properly because the callisto output was currupted
356
357 - general: a script called scripts/makemovie has been added which
358 simplified the process of producing several movies from a single
359 sequence with different setup.
360
361 - callisto: Some more code cleanup. Started to remove old obsolete
362 code from cvs.
363
364 - callisto: The extraction of the pedestal with the extractor was
365 not random. It seems that extracting at one position is still biased
366 (for example in the first or last slices we could still suffer from
367 switching noise) Now it is completely random.
368
369 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
370 pedestal files) individual pixels could be skipped due to high
371 variations. This was already the case for the pedestal extraction
372 from the lo-gains since the beginning and properly handled
373 there, but was introduced in the extraction from the pedestal files
374 a while ago. To calculate the average value it was still divided
375 by the number of events procesed not by the number of summands
376 really summed. This let to a pedestal which was a tiny amount too
377 small (for a few piels in the order of 0.1%). This led to an slightly
378 positive offset of the randomly extracted pedestal for a few pixels.
379 I doubt that this has a big effect on the result, because the effect
380 on the individual numbers is quite small. Due to this it is suggested
381 that you rerun your calibration to make sure you are without any
382 avoidable bias.
383
384 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
385 the median rms of the absolute arrival time and expressed in significance
386 levels. This replaces the old meaning of an abolute upper limit. An
387 absolute upper limit doesn't make much sense, because in our data
388 all arrival times are shifted at the same time (in fact it might be
389 a shift of the artificial trigger w.r.t. to the light flash).
390
391 - callisto: Added a new tab "BadPixTm" which shows the time evolution
392 of the number of unsuitable pixels over the whole sequence. This
393 is usefull mainly to judge if an intermediate calibration had
394 problems.
395
396 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
397 of the number of dead pixels over the whole sequence. Dead pixels
398 in this context are unmapped pixels, i.e. pixels which could not
399 be interpolated, and thus are ignored in the further analysis.
400
401 - callisto: It is now possible to use the position of the maximum
402 of the spline as arrival time instead of the leading edge even
403 when using the integral for the signal. Therefor set the extraction
404 type to kIntegralRel ("IntegralRelative") and the relative height
405 ("HeightTm") to -1:
406 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
407 MJPedestalC1.ExtractSignal.HeightTm: -1
408
409
410
411
412 *** Version 1.1 (2007/04/27)
413
414 - general: The new class MGeomCamDwarf contains the camera geometry
415 for our prefered Dwarf camera and can be used to create general
416 geometries of roundish or hexagonal cameras.
417
418 - mars: The default cleaning is now abolute 8.5/4.0.
419
420 - mars: The resource file mars.rc now contains examples for MUX data
421
422 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
423 data containing only 10-bit information is still cooked down to
424 8-bit, by cutting away the lowest 8-bit.
425
426 - merpp: When reading raw data the data is now stored in a single
427 array. The lo-gain array is obsolete. The interface stays the same.
428
429 - callisto: To process the new MUX data use the resource file
430 callisto_mux.rc
431
432 - callisto: The -root and -raw options to read merpped raw data have
433 been removed
434
435 - callisto: If the -mc option is given the sequence-name can now be
436 replaced by the MC sequence number
437
438 - callisto: If the sequence file contains "MonteCarlo: Yes" the
439 -mc option can now be omitted
440
441 - callisto: Started further simplification by removing obsolete
442 dependancies on MCalibIntensity*Cams.
443
444 - callisto: removed unsused intensity calibration from MJCalibration
445 for further simplification
446
447 - callisto: for simplification removed references to
448 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
449 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
450 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
451 (this should at minimum change nothing at all, and at maximum
452 improve thing if these containers where somewhere not handled
453 properly)
454
455 - callisto: Added the option to write an event movie. Please use
456 this option with care (huge files) but exessively to understand
457 our events. For further documentation please refer to the
458 IACT wiki
459 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
460
461 - callisto: Improved binning for the pulse position check histogram
462
463 - callisto: The code calculating the pulse position checknow takes
464 the pedestal into account
465
466 - callisto: The arrival time is now stored with full precision this
467 helps to get rid of artefacts in histograms. For the signal this
468 is not necessray because it is displayed in log-scale anyhow
469
470 - callisto: Fixed a problem with internal exclusions. Pixels which
471 have once been marked as unsuitable didn't get the necessary
472 histograms filled anymore to be rechecked with each interleaved
473 calibration.
474
475 - callisto: The relative arrival time resolution (the rms of the
476 relative arrival time offset) is now checked against its
477 median and the median deviation, instead of the average
478 plus an absolute offset.
479
480 - callisto: The relative arrival time offset is now calculated
481 w.r.t. its median not w.r.t. to an artificial reference pixel.
482
483 - callisto: The relative time calibration now marks pixels with
484 outlaying offset as unsuitable
485
486 - callisto: The interleaved relative time calibration has been switched
487 on. The advantage is that pixels which are marked as outliers
488 now can recover. An improvement over time is not expected, because
489 the relative time calibration seems stable.
490
491 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
492 option can now be omitted.
493
494 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
495 or the option "-mc" is specified as default the monte carlo datacenter
496 paths (/magic/montecarlo/...) are used if not overwritten in the
497 dataset file.
498
499 - ganymed: The output files now contain run- and event-number for all
500 events, accessible as RunNumber.fVal and EvtNumber.fVal
501
502 - ganymed: Added a plot showing the source position in the camera also
503 for wobble mode
504
505 - ganymed: In addition to the existing task which can be setup to
506 be executed after Cut1 a final task called "EstimateEnergy"
507 has been added, executed before writing the final output
508 (ganymed00000000.root). The task setup in all three cases
509 can be choosen individually. (For all three(!) cases you
510 can for example choose MRanForestCalc. For examples see all
511 sponde*.rc and all ganymed*rc)
512
513 - ganymed: If a container "MEstimatedEnergy" is found in the
514 parameter list (eg. because it was setup by MEstimateEnergy)
515 it will be written to the output file.
516
517
518
519 *** Version 1.0 (2007/02/16)
520
521 - database: Website to plot values from the database has been added.
522
523 - database: The rate of spark events as found by star is now kept
524 and the rate after cleaning is now with spark events subtracted
525
526 - general: The changes to the interpretation of phrases lead to
527 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
528
529 - general: Added example files how you can create your own calendar
530 (eg. as christmas present) with Mars. Just run
531 root macros/tutorials/calendar.C
532
533 - general: Added a possibility to display grouped data in the plotdb.C
534 macro (and similar macros). This allows to plot hourly, nightly,
535 weekly, monthly and yearly averages.
536 For more details see the plotall function of the macro
537
538 - general: fixed the error display of the camera display. It showed
539 wrong results.
540
541 - general: fixed a memory leak when reading many MStatusDisplays
542
543 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
544 between a spherical and a parabolic mirror
545
546 - callisto: We have a new pulse position check which takes the properties
547 of the extractor automatically into account. So no need to set
548 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
549 left is done. If possible the lo-gain extraction start and hi-gain
550 extraction end is changed accordingly. If no proper extraction range
551 can be set (hi-gain too much to the left) an error is raised.
552
553 - callisto: New swapped pixels have been found and corrected
554
555 - callisto: Redone the signal extraction this includes:
556 + Unified the algorithms to extract the pedestal for all pedestal
557 extractions done
558 + Unification of hi- and lo-gain into one array
559 + Unification of hi- and lo-gain extraction for Spline and
560 Digital Filter (means now exactly the same algorithm is used,
561 not a copy-and-pasted one)
562 + Store pedestal subtracted data in a common place
563 + Improved extraction algorithms. If the algorithms search a
564 maximum but don't find one they don't return the maximum anymore
565 + Improved the extraction such that a information for signal
566 and time which is consistent is returned
567 + replaced the numerical spline with a (not slower) analytical
568 solution
569 + Lowered the saturation limit from 250 to 245 to make sure that
570 we are far away in all pixels from problems with the clock-noise
571 + The start of the lo-gain extraction is calculated from the hi-gain
572 arrival time. In case of saturation an estimation is used.
573 + the hi-gain window was extended to slice 16. This allows extraction
574 of very late pulses in single pixels or of huge hadron showers.
575 + Now uses the lo-gain extraction range for pedestal extraction,
576 not the hi-gain range in the lo-gain
577
578 - callisto: New hi-/lo-gain calibration constants have been produced
579 for all periods from the statistic of the whole period. They are
580 now used automatically depending on the periods. The old constants
581 where deviation in avarega about 2%-3%. The constants are very
582 stable from period to period (<<1%) except for exchanged channels.
583 In a few cases the constants used so far were off by 1%-2% (maybe
584 temperature effects?)
585
586 - callisto: To gain obsolete space we do not write the
587 MPedestalFundamental anymore. Also calibration and bad pixel
588 treatment is not done for it anymore because it has never been used.
589
590 - callisto: Fixed a bug in the seuqence handling which caused the
591 light condition to be ignored
592
593 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
594 basically the same as "Cleaned" but the distribution devided into
595 the events fullfilling a spark cut or being rejected by it.
596 This cut can be changed from star.rc (see example inside) by
597 the "SparkCut" directive
598
599 - star: Star displays now the average individual pixel-rate (IPR) versus
600 time and the average discriminator threshold (DT) of all pixels.
601
602 - optim: fixed a problem with the optim-macros which was due to a bug
603 in the new phrase parsing
604
605 - ganymed: To get a nice FalseSource plot (instead of the all-information
606 debug plot displayed as a standard plot) use the context menu
607 somewhere between the two upper plots, click on "DrawNicePlot"
608 and enjoy the result. (It is the same context menu which contains
609 the other options)
610 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
611
612 - ganymed/optim/train: The cut program, trainings- and optimization
613 macros could run with less files found than expected from the
614 sequence-files. No the execution is stopped in this case.
615
616 - ganymed: now stores the dataset in the output file with all information
617 contained (as sequence number, sequence path, data path) so that the
618 used dataset file can be recreated complete from the output
619
620 - sponde: now also allows the uasge of random forest
621
622 - sponde: added a plot showing the cut efficiency
623
624 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
625 errors (eg. effecting the collection area) because the errors of the
626 two histograms were swapped in the calculation, which makes a difference
627 in the case the histograms contains weighted events. Aditionally the
628 totalarea was incorrectly taken into account, which results in too small
629 errors, which makes a difference at low statistics were the errors
630 or the collection area dominate.
631
632
633
634 *** Version 0.10.3 (2006/10/23)
635
636 - database: Implemented ObservationMode flag in websites.
637
638 - database: For sequences there is now also the stoptime available on the
639 websites.
640
641 - database: Removed ManuallyChanged flag from sequence-info websites,
642 as it is not needed anymore with the new sequence building algorithm.
643
644 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
645 Class for calculation of confidence intervals (upper limits).
646 Use model 3 or 4 for upper limit calculation for MAGIC observations.
647 Please read the class instruction of TRolke for more information.
648
649 - general: The programs now return 0xfe if the requested resource file
650 doesn't exist.
651
652 - general: Errors comming from root itself are now not output to
653 stderr anymore but to our default (colored) log-stream.
654
655 - general: Changed the interface to TFormula such that now everything
656 is parsed by TFormula, which should allow to use phrases even
657 without paranthesis correctly parsed.
658
659 - callisto: replaced the AdHoc number of effective integration slices
660 in the digital filter by an average of the correct number, averaged
661 over all possible set of weights. This also gives correct numbers
662 for the lo-gains which were totally wrong before.
663
664 - callisto: drastically reduced memory consumption by not storing
665 all intermediate calibration results in memory anymore (we might
666 write them into a file in the future)
667
668 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
669 debug plot displayed as a standard plot) use the context menu
670 somewhere between the two upper plots, click on "DrawNicePlot"
671 and enjoy the result. (It is the same context menu which contains
672 the "DrawAll" option)
673 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
674
675
676
677 *** Version 0.10.2 (2006/10/15)
678
679 - general: changed the building of the sequence files such, that
680 the source-/project name in case of wobble-sources is not the
681 source/project of the first data run anymore but the new generalized
682 wobble source/project
683
684 - general: Added some functions to MAstro to calculate sun and
685 moon properties
686
687 - general: Added two new macros (starvisday.C and starvisyear.C)
688 which allow to plot the visibility of several stars in one day
689 or of one star along one year
690
691
692
693 *** Version 0.10.1 (2006/10/11)
694
695 - general: HTML logging output was distorted... fixed.
696
697 - general: Changed the writing of the sequencefiles such that only
698 as many pedestal files as giving at least 1000 pedestal events which
699 are nearby the first calibration run are used as pedestal runs
700
701 - sponde: In the calculation of the collection area(s) and the
702 distribution for MOnte Carlo and estimated energy the error
703 calculation was wrong because root didn't take the errors
704 properly into account... fixed.
705
706
707
708 *** Version 0.10 (2006/10/10)
709
710 - general: all executables now check consistency of the root version
711 installed with the root version used for compilation. The return
712 code in this case is 255.
713
714 - general: The algorithm to build seqeunces has been redesigned
715 completly. It is now more flexible in terms of a resource file
716 resources/sequences.rc which can be used to partly overwrite
717 the default algorithm and defined the important part of the
718 algorithm. It also takes correctly into account several ways
719 of taking wobble-data. Currently the new algorithm doesn't take
720 the number of pedestal events anymore into account (so a sequence
721 could have much less than 1000 pedestal events and data runs are
722 no-more used instead)
723
724 - general: a lot of small changes to make the code compatible with
725 root 5.12/00 and gcc 4.1
726
727 - general: Fixed some warnings thrown if more warnings are switched
728 on in the compiler
729
730 - general: Added a function to MMath which returns the Median of
731 the distribution abs(y[i]-median) but at 68:32 division instead
732 of 50:50, which is somehow the median counterpart of the rms.
733
734 - general: MAstroCatalog allows now to read calatog files (as bsc5)
735 even if they are compressed with gzip (recommended compression
736 is with "-1")
737
738 - showplot:
739 + batch mode creation of image files now works with root 5.12/00
740 + added support for writing bmp (though it never produces
741 bmp which can be read by programs like xv or gimp)
742 + added support for xml
743 + added new option to start the display with a different size, by
744 --display-width=nnn or --display-height=nnn
745 + added options to define the canvas size when the display is started
746 --canvas-width=nnn or --canvas-height=nnn
747 the option can also be used for batch-mode conversion
748 + added an option which automatically fits the display size to the
749 desktop-size: --auto-size
750
751 - merpp: didn't recognize files with the extension .raw.gz - fixed.
752
753 - merpp: allow the reports to have 1000ms due to a bug in the camera
754 program.
755
756 - callisto: New swapped pixels have been found and corrected. For
757 details see MRawRunHeader::FixAssignment()
758
759 - callisto: Callisto now raises an error if one of the input files could
760 not be opened.
761
762 - callisto: In some rare cases it could happen that in the signal
763 extraction of the digital filter the extractor returned nonsense
764 results due a wrong initializion of a variable (this happens in
765 cases in which the extracted signal is exactly zero or the
766 digital filter couldn't slide because of a too small extraction
767 window, which could happen in the lo-gain extraction)
768
769 - callisto: The lo-gains have been marked as valid in some cases
770 when they got not extracted at all (deltsumlo=deltatimelo=0) because
771 the allowed extraction range (fLoGainLast-fLoGainFirst) was
772 smaller than the number of slices (fLoGainWindowSize) needed
773 by the lo-gain extractor
774
775 - callisto: Updated absolute calibration constants (muon calibration)
776
777 - callisto: fixed a bug which caused the hi-gain saturation not
778 to be handled properly in the spline (the position of the
779 saturation was calculated incorrectly)
780
781 - callisto: fixed a bug which gave weird results if hi- _and_
782 lo-gain could not be extracted properly. In some cases hi-
783 and lo-gain have not been extracted at all and the random result
784 got calibrated. In other cases the hi-gain was saturating and the
785 lo-gain has not been extracted. For this a completly arbitraty
786 scale factor was applied to the result from extracting the
787 charge of the saturating hi-gain.
788
789 - callisto: improves handling of extracted signal if lo- and/or
790 hi-gain could not be extracted properly. If no appropriate
791 calibration of either the signal or the arrival time is possible
792 the pixel is now markes as unsuitable instead of estimated.
793
794 - callisto: Fixed a problem in the spline extraction which gave
795 weird results if the signal was extracted from the first (and
796 highest) slice (as a workaround extraction from the first
797 slice has been forbidden)
798
799 - callisto: Fixed a bug regarding the use of the QE which doesn't
800 effect the result because the default is used anyhow.
801 (The bug was there since 14/07/2005)
802
803 - callisto: Changed the default for fgLoGainStartShift to -2.4
804
805 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
806 factors to be always 10 for all pixels as soon as the first
807 calibration update has happend.
808
809 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
810 was off by more than one slice (which gives wrong values for
811 pixels which have saturated the hi-gain) This was a problem
812 mainly for timing studies, not so much for the automatic standard
813 analysis. Also the values for the Spline have been changed slightly:
814 + Digital Filter from 1.70 to 0.95
815 + Spline from 1.39 to 1.30
816 The numbers were sorted out by an extensive test in the
817 test-database.
818
819 - callisto: Removed the tab showing the average calibrated arrival
820 time. It never gave useful information.
821
822 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
823 lo-gain pulse for data pulses if hi- and lo-gain have saturated
824 and both were extracted because the hi-gain was above the
825 LoGainSwitch.
826
827 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
828 lo-gain pulse position (after application of LoGainOffset, which
829 means in the ideal case it is 0) for data pulses if hi- and lo-gain
830 have saturated and both were extracted because the hi-gain was above
831 the LoGainSwitch.
832
833 - callisto: After extensive tests a new threshold level for determination
834 of the pulse position has been found at 50phe. This is due to the
835 fact that for lower pulses the arrival time changes its average
836 behaviour dramatically. It tends to the average of the extraction
837 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
838
839 - callisto: Added two more plots to the calibration part. The average
840 extracted signal and the average extracted arrival time as
841 extracted by the signal extractor (This can help debugging problems
842 because it doesn't involve a fit)
843
844 - star: changed the fit for the effective on time such that initial
845 values are calculated automatically now instead of using build
846 in values. This makes the fit more indepedant of the underlaying
847 rates. With a test of ~350 sequences in the test database it could
848 be shown that the new fit gives the same result +/-1sek.
849 The highest deviation was +5s the lowest -10s. You can now control
850 the bahaviour with two resource values:
851 MHEffectiveOnTime.FistBin: 3
852 MHEffectiveOnTime.NumEvents: 12000
853 Use FirstBin=1 and NumEvents=120 to fit the effective on time
854 from the resulting gamma candidates
855
856 - star: The Center histogram in MHHillas is now by default displayed
857 with the colz draw-option
858
859 - ganymed: now produces valid error codes if failed
860
861 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
862 with the option "hadronness" instead of "area" or "both" if
863 you want to use both cuts. The hadronness cut includes a fixed
864 cut in hadronness (index 8) and a fixed cut in size (index 9).
865
866 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
867 the M3Long of the anti source to be not properly evaluated
868 (actually is was evaluated as a unique random number) in case
869 of optimization with anti-theta cut switched on. This might have
870 lead to improper, but not necessarily wrong, optimization results.
871
872 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
873 how to use random forest
874
875 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
876 ganymed_onoff.rc. Seems to be unintentional that they were different.
877
878 - sponde: Since the introduction of the possibility to define a
879 normalization energy instead of using the integral the default
880 was not using the integral anymore but a normalization energy of
881 1GeV. It is now the integral again.
882
883 - sponde: Fixed a problem in the weighting which did not allow
884 a MC slope of -1.
885
886
887
888 *** Version 0.9.6 (2006/05/24)
889
890 - general: changed the binning of the azimuthal profile of the camera
891 such that it is aligned with the 60deg boundaries.
892
893 - merpp: better handling of problems with the TH, TD part of the
894 CC-REPORT for files older than 200507190 and 200412210
895 respectively
896
897 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
898
899 - merpp: implementd latest changes in starguider reports (sinc 9th May)
900
901 - callisto: if an arrival time is extracted outside the fadc range is
902 was set to the boundary before. Now a random number is assigned
903 instead to avoid unfortunate coincidences of arrival times just
904 by this arbitrary value.
905
906 - callisto: added a new option to callisto.rc which allows
907 to set the maximum arrival time difference allowed for the
908 badpixel algorithm to determin whether a pixels belongs to a shower:
909 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
910
911 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
912 to 0.9 as suggested by Stefan due to a recent study on the fraction
913 of pixels surviving the image cleaning
914
915 - callisto: switched off error in case of "pulse is too much to the left"
916
917 - callisto: The extraction window is not adapted anymore. This means that
918 the pulse is extracted from the full range. The draw-back is that the
919 background (pedestal) will become slightly higher. Switching on/off
920 the PulsePosCheck in the callisto.rc only effects filling the
921 histograms.
922 WARNING: If the pulse is too much to the left data is calibrated!
923 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
924 in the database to make sure that your data is valid!
925
926 - star: Show also the number of stars correlated correctly by the
927 starguider
928
929 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
930 than one off-source region in wobble-mode. To use it add the following to
931 your ganymed_wobble.rc:
932 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
933 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
934 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
935 + Cut1.ThetaCut: None
936 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
937
938 - ganymed: in the case the latest report is older than a default (currently
939 one minute) and the current report will be skip the starguider
940 correction and calibration will be reset. The maximum age can be
941 setup from ganymed.rc by (minutes):
942 MPointingDevCalc.MaxAge: 1.5
943
944 - ganymed: A first implementation showing all size-bins for the theta-sq
945 resp. alpha-plots in a single tab automatically
946
947
948
949 *** Version 0.9.5.1 (2006/05/05)
950
951 - general: Added a new option "zdiff" to the Makefile which runs
952 "cvs diff" as "make diff" would do, but with compression
953
954 - general: accelerated MTFillMatrix (used for eample in all training
955 and optimization macros) by skipping some obsolete calles in the
956 eventloop the first and second loop could be accelerated by ~20%
957
958 - general: Added a missing feature in the MFilterList class which
959 prevented MFEnergySlope from working correctly in trainenergy.C
960
961 - general: Accelerated the random forest training and usage a bit
962
963 - merpp: Adapted to new raw data file format version 6
964
965 - merpp: fixed a problem with reading the starguider reports
966 after 6.3.2006
967
968 - callisto: At some times six pixels had to be exchanged manually in the
969 data. If the pixels to be swaped are both not found, an error was raised
970 and calibration was stopped. Now it is assumed they are intentially not
971 mapped and the Error has been changed to a Warning.
972
973 - star: Added new image cleaning based on the arrival time of the shower.
974 The new cleaning can be accessed using the parameter "Time" instead of
975 the the old one (like "Absolute) in the star.rc-file.
976 Recommended parameters:
977 + MImgCleanStd.CleanLevel1: 8.2
978 + MImgCleanStd.CleanLevel2: 5
979 + MImgCleanStd.CleanRings: 2
980 + MImgCleanStd.KeepSinglePixels: No
981
982 - star: Simplified the calculation of the effective on time. By letting
983 the fit start in the third bin the result should become more stable.
984 The fit quality is now ignored for the theta-plot which is not used
985 in the analysis later. Still better pre-cut which, for example,
986 remove events triggered by car-light (rate changing on a short
987 time-scale) are missing.
988
989 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
990 for optimization (kWeakSource) which is suggested by the Berlin
991 people for weak sources.
992
993 - macros: plotdb.C:
994 + if no dataset and no time-interval is given only sequences with
995 an effective on-time above five minutes are plotted anymore
996 + added a new tab "RelTime" displaying the relative on-time
997 (effective on-time divided by the observation time)
998
999 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1000 the optimization became a lot faster
1001
1002 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1003 To display them just delete the pads displayed on top.
1004
1005 - ganymed: fixed a bug which could cause strange behaviour in wobble
1006 mode if no starguider information was available due to an incorrect
1007 initialization of the starguider calibration
1008
1009 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1010 be changed from within the plot. It can also be setup from the
1011 resource file using:
1012 + MHDisp.fScaleMin: 0.325
1013 + MHDisp.fScaleMax: 0.475
1014
1015 - ganymed, showplot: Fixed a problem with the fit to the off-data
1016 (HistOff) which could cause a time lag or an inifinite loop.
1017 The bug did not effect the results at all.
1018
1019 - sponde: Added a new tab showing the effective collection area after
1020 trigger (including the software trigger)
1021
1022 - sponde: MMcSpectrumWeight has a new option which allows to define
1023 the scaling factor not by the integral of the events but at
1024 a defined energy:
1025 e.g. MMcSpectrumWeight.NormEnergy: 200
1026
1027 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1028 eventloops the loop could be accelerated by ~20%
1029
1030
1031
1032 *** Version 0.9.5 (2006/03/13)
1033
1034 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1035 and added the standard Disp-parametrization
1036
1037 - macros: added a new macro datacenter/macros/plotstat.C allowing
1038 to plot statistics about the data processing
1039
1040 - macros: added a new macro to plot the muon correction coefficients
1041 versus period (macros/plot/mucal.C)
1042
1043 - showplot: path inflation for ganymed files was broken
1044
1045 - callisto: Fixed an important bug. When the number of saturating pixels
1046 were calculated the bad pixel information already available from the
1047 calibration was ignored. This yields wrong values in case pixels
1048 are broken and saturate all the time or randomly.
1049
1050 - callisto: Updated Muon calibration constants. Spline data now also uses
1051 different values for different periods
1052
1053 - star: The time-evolution shown in the effective on-time plot now displays
1054 the axis range (if there are no holes it should be similar to the
1055 effective on-time)
1056
1057 - star: Added two new image parameters:
1058 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1059 the three pixels next to the center of gravity and the size
1060 + MNewImagePar.fConcCore: The ratio of the signals of all
1061 pixels inside or touching the ellipse and the size
1062
1063 - ganymed: now stops in requested source isn't found in catalog file
1064
1065 - ganymed: Many improvements to the phi-plot in wobble mode:
1066 + with a template the ideal background is displayed
1067 + a possible camera inhomogeneity is taken into account
1068 + the anti theta cut is better supported
1069 + the phi cut is automatically calculated from the theta cut
1070 See the examples in ganymed_wobble.rc for more details.
1071
1072 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1073 times the bin-width instead of the absolute energy
1074
1075 - ganymed: New cuts for on/off and wobble mode
1076
1077 - ganymed: The smearing of the False Source plot has been increased
1078 to 0.06
1079
1080 - ganymed: The starguider calibration can now be changed from the
1081 resource file.
1082 See the examples in ganymed*.rc for more details.
1083
1084 - ganymed: added a new option for on-/off-observations
1085 MJCut.RandomSourcePosition
1086 If switched on the distribution of observation time of the source
1087 position in the camera is calculated from the on-data and randomly
1088 applied with this distrbution to the off-data.
1089
1090 - ganymed: by skipping some obsolete calles in the eventloop the
1091 first and second loop could be accelerated by ~20%
1092
1093 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1094 position in the off-data randomly according to its distribution in the
1095 on-data.
1096
1097
1098
1099 *** Version 0.9.4.3 (2006/02/13)
1100
1101 - general: Fixed a bug in most of the programs which prevented the
1102 compile date in the startup message to be displayed
1103
1104 - general: Simplified program calls. The following abbreviations
1105 are now possible:
1106 showlog callisto 55599
1107 showplot signal 55599
1108 star 55599
1109 callisto 55999
1110 ganymed 2
1111 In this cases the corrsponding root-, log-, sequence- or dataset-
1112 filename is automatically compiled using the default datacenter
1113 paths ("/magic/*")
1114
1115 - general: Fixed a long outstanding bug which made axis tick marks
1116 disappear if MDataFormula was used (eg. abs(x))
1117
1118 - general: Updated MMath with new functions to calculate the results of
1119 a exponential, logarithmic and powerlaw fits analytically.
1120
1121 - general: Updated some macros with comments:
1122 + macros/optim/optimdisp.C
1123 + macros/optim/optimenergy.C
1124 + macros/optim/optimwobble.C:
1125
1126 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1127 files) now allows adding a pre-cut like in the optimization. E.g. this
1128 is useful to perform g/h-separation cuts before training the random
1129 forest.
1130
1131 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1132 correctly assigned in the raw data assignement table. A fix to correct
1133 the assignment tabel have been implemented.
1134
1135 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1136 by 90, 180 and 270 deg.
1137
1138 - general: the macro plotdb.C now allows to highlight sequences belonging
1139 to a datset. For more details see the descritions in the macro.
1140
1141 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1142 of the display, it gave wrong results espacially for big sizes.
1143 Now the embedded canvas should always have a ratio width/height=3/2.
1144 The "Size" options have been updated with values fitting the 3/2
1145 size ratio.
1146
1147 - RanForest:
1148 + Updated the random forest classes to support also the
1149 regression method implemented by Thomas H.
1150 + added new tutorial macro how to train the random forest
1151 for energy estimation (macros/optim/rfenergyest.C)
1152 + new classes to train the random forest (still in development)
1153 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1154 + new tutorial macros for random forest training in macros/train
1155 trainenergy.C, traindisp.C, trainseparation.C
1156
1157 - mars: now allows to setup a cut in the resource file mars.rc to choose
1158 the events to be displayed, eg:
1159 Cut.Condition: {0} && {1}
1160 Cut.0: MHillas.fSize>100
1161 Cut.1: MHillas.fSize<900
1162
1163 - merpp: Made aware of the new .rep format 200510250. This includes
1164 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1165 the discriminator thresholds (MCameraTD) and the disciminator
1166 delays (MCameraTD). All of them come with the CC report and are therefor
1167 written to the CC tree.
1168
1169 - callisto: fixed a bug in the calculation of the arrival times in
1170 the Digital Filter. They were all shifted by the same amount
1171 fHiGainFirst. This caused an offset in the order of the position of
1172 the left border of the extraction window in the times calculated
1173 from high-gain and from low-gain. The bug effected only the absolute
1174 arrival times. The bug was there since 30.1.2005.
1175
1176 - callisto: Changed the ExtractionWindow for the pulse position check
1177 such that the camera inhomogeneity becomes as less as possible and
1178 comparable to the pulso position check switched off. More details
1179 on the study will be given at our result web-page.
1180
1181 - ganymed: ganymed.rc, ganymed_onoff.rc:
1182 changed to new cuts trained with 1ES1218 and Crab-data
1183 for maximum sigma*log10(excess)
1184
1185 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1186 a new option was implemented to estimate Disp (CalcDisp)
1187
1188 - ganymed: Implemented two new options which allow
1189 to overwrite the default path to search for the sequence files
1190 --ins=/magic/sequences
1191 and where to search for the image data
1192 --ind=/magic/data/star
1193
1194 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1195 dx/dy from the resource file by
1196 MSrcPosCorrect.Dx
1197 MSrcPosCorrect.Dy
1198
1199 - ganymed: fixed reading the source catalog. Only as many chars
1200 as the requested source name had were compared (If a source
1201 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1202 were requested it could happen that the coordinates of
1203 "1ES1218" were read) The source coordinates are now printed
1204 in addition to its name to the logging output.
1205
1206 - ganymed: changed the background fit in the case of a ThetaSq function
1207 from a polynomial to a exponential, this should give a big improvement
1208 for on-only analysis'
1209
1210 - ganymed/sponde: Calculation of the error of single size-/energy-
1211 bins now uses Li/Ma (5) instead of LiMa (17)
1212
1213 - sponde: Added a plot E^2*dN/dE
1214
1215 - sponde: The energy estimator plot should now show values like
1216 they are commonly used.
1217
1218 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1219 (a powerlaw with cutoff didn't work before)
1220
1221
1222
1223 *** Version 0.9.4.2 (2005/10/01)
1224
1225 - general: added new tutorial macro macros/tutorials/threshold.C:
1226 how to calculate the threshold
1227
1228 - general: added a new game. Start it from the interpreter with
1229 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1230 and MagicReversi)
1231
1232 - general: neighbor pixels in MGeoms are now sorted clockwise
1233
1234 - merpp: made aware of new format 20050829-0
1235
1236 - callisto: New scale factors from muon analysis, stored in new
1237 resource file resources/calibration.rc
1238
1239 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1240 the eventloop if something went wrong. This is necessary for the
1241 automatic processing
1242
1243 - callisto: Implemented a new treatment for the time information
1244 developed by S.Ruegamer, this should give much better response than
1245 the old very primitive algorithm. This is especially important
1246 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1247 treatment was buggy! As neighbor pixels to interpolate the
1248 arrival times always the pixels 0 to 5 were taken)
1249
1250 - callisto: In addition to the new treatment of arrival times the
1251 decision of the treatment whether a pixel contains shower
1252 information or not is used to improve the signal interpolation
1253 further. Previously interpolated pixels showed a non-zero signal
1254 do the peak searching signal extractors. Having a signal pixel
1255 beside raised the signal above the cleaning level. Thus the
1256 pixel survived cleaning to often but with a too low mean signal.
1257 By replacing empty pixels with a gaus (mean and rms from the
1258 corresponding Area entries in MPedPhotCam) this effect can
1259 be supressed.
1260
1261 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1262 got lost when the events were stored by the calibration... fixed.
1263 (This was no problem for normal image cleaning because the pixel
1264 content was artificially set to 0 not surviving standard cleaning
1265 algorithm)
1266
1267 - callisto: Fixed a bug which caused the random and peak-search pedestal
1268 extracted with an extractor to be exchanged for the first (roughly)
1269 500 events (*Extractor and *ExtractorRndm).
1270 (They were simply exchanged in callisto.cc) This bug might have been
1271 introduced in Mars 0.9.4 when the order of calculation of the two
1272 types of pedestal in callisto got exchanged. The bug only effects
1273 the first seconds of data of each sequence.
1274
1275 - star: Taking the arrival time of Muons into account the calculation
1276 of the parameters could be made independant of the noise
1277 (pedestal rms). The dependance was due to the bias of the peak search
1278 extractor. Now only a ZA dependamcy is left which is not yet fully
1279 understood.
1280
1281 - ganymed: The sequences were still not sorted correctly in any case,
1282 because they were sorted by the full qualified path name. Now they
1283 are sorted by their sequence number.
1284
1285 - ganymed: new values for the spark-event-cut
1286
1287 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1288
1289
1290
1291 *** Version 0.9.4.1 (2005/08/18)
1292
1293 - callisto: fixed some problems with the calibration in case of
1294 inteleaved events. Therefor the final and some intermediate
1295 fits are skipped which would take place on partly filled #
1296 histograms and gave wrong results or failed completely.
1297
1298 - callisto: If the intermediate finalization of the histograms
1299 calculating the mean charge of the calibration signal fails
1300 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1301
1302 - ganymed: Fixed some bugs which caused problems in On-only mode.
1303 Still the false source plot doesn't give reasonable results.
1304
1305
1306
1307 *** Version 0.9.4 (2005/08/05)
1308
1309 - general: Fixed the ZA binning. It did not correctly fit the
1310 MC binning
1311
1312 - general: Added a class to correct for the missfocussing in
1313 April (MSrcPosCorrect)
1314
1315 - general: Random Forest energy estimator should now work properly
1316
1317 - general: MHCamera now displays the profiles in deg instead of mm
1318
1319 - general: MH::SetPalette offers a lot of new palettes
1320
1321 - general: MHillas - the case of CorrXY==0 is now handled properly
1322
1323 - general: implemented the possibility to change the line and
1324 marker style of a sky-grid drawn by MAstroCatalog
1325
1326 - general: Runs in sequences and datasets are now automatically
1327 ordered (it is assumed that the order of their filenames correctly
1328 represents the order of observations) to ensure correct reading
1329 of the subsystem data
1330
1331 - general: Runs cannot be added to a sequence twice anymore. Also
1332 Sequences cannot be added twice anymore to a dataset.
1333
1334 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1335 It gave wrong results by 1./2pi
1336
1337 - showplot: got a new option to start a root interpreter, too
1338
1339 - mars: now displays a rough estimate of Disp and the third moment
1340
1341 - mars: now displays the event time MTime if available
1342
1343 - mars: show muon parameters graphically
1344
1345 - mars: now the file to open can be given as commandline
1346 argument
1347
1348 - merpp: Added support for new arehucas version >= 200507190
1349 implementing values for three temperature sensors in the
1350 counting house (MCameraAUX) and the name of the HV settings file
1351 (MCameraHV).
1352
1353 - merrp: Also fixed some problems with wrong versions numbers stated
1354 by arehucas and implemented some fixed for old versions (<200407070)
1355
1356 - callisto: MCalibrationHiLoCam can now be printed from its context
1357 menu, eg in the TBrowser
1358
1359 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1360 - 1.39 (MExtractTimeAndChargeSpline)
1361 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1362 This is important mainly for timing studies.
1363
1364 - callisto: Changed limits in MHCalibrationChargeCalc from
1365 - -100.125 to -98 (fgChargeHiGainFirst)
1366 - 1899.875 to 1902. (fgChargeHiGainLast)
1367 - -100.25 to -99 (fgChargeLoGainFirst)
1368 - 899.75 to 901. (fgChargeLoGainLast)
1369 Introduced new limits:
1370 - fgNumLoGainBlackoutLimit: 0.05
1371 - fgLoGainBlackoutLimit: 3.5
1372 - fgLoGainPickupLimit: 3.5
1373
1374 - callisto: The handling of automatic weights for the digital filter
1375 has been improved. There are now new calibration weights special
1376 for Monte Carlo calibrations.
1377
1378 - callisto: Updated Muon scale with latest results (1% difference
1379 for most data, 5% for Mar/Apr'05)
1380
1381 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1382 was saturated and the blackout-events in the low-gain exceed the
1383 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1384 This excludes those pixels which have a saturating high-gain
1385 channel, but the low-gain switch does not switch often enough
1386 to make the distribution reliable.
1387
1388 - callisto: fix a bug counting the number of saturated events. Up to now,
1389 the number of saturated slices was counted (which is one for a not too
1390 high number), but for some (pathological) pixels, many more slices
1391 saturated and produced wrong limits.
1392
1393 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1394 + MCalibrationRelTimeCam.CheckFitResults: Yes
1395 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1396 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1397 + MCalibrationRelTimeCam.CheckOscillations: Yes
1398
1399 - callisto: introduce max. number of events for intercalibration,
1400 the rest gets skipped. Default: 4096
1401 The calibration causes too many un-reliable pixels if more
1402 than about 5000 events are treated (@500 Hz) because of the
1403 mode hopping of the VCSels. However, in the past, some
1404 calibration runs have been taken (erroneously) with more
1405 than 5000 events, especially the intensity scans where
1406 a good precision is needed.
1407
1408 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1409 photo-electrons for the spline extractor by 1-2% (correctly).
1410
1411 - callisto: The intercalibration is now done using a full f-factor
1412 method instead of a simple update. This makes things slower but
1413 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1414 changes.
1415
1416 - callisto: MPedestalY3 now uses the same extraction range as the data
1417 as calculated by MPedestalY2
1418
1419 - callisto: A check of the fraction of allowed unsuitable (10%) and
1420 unreliable (30%) pixels has been addded when the conversion is
1421 calculated from interleaved events
1422
1423 - star: fixed a bug which caused MEffectiveOnTime containers not to
1424 be written. In the worst case they were skipped almost all, in the
1425 best case they were all ok. It depends on how often the new value
1426 was assigned just with an event which was skipped later by another
1427 task
1428
1429 - star: new histograms MHPointing and MHRate
1430
1431 - star: New tab (Currents) displaying the time evolution of the mean
1432 DC currents
1433
1434 - star: New tab (MeanRms) displaying the time volution of the mean
1435 Pedestal Rms
1436
1437 - star: Output now contains MReportStarguider
1438
1439 - star: Improved muon analysis. Due to the absense of a constant
1440 for the gaus fit for arc width and the fact that the arcwidth
1441 plot was a histogram instead of a profile the resulting psf
1442 became pedestal rms dependant
1443
1444 - ganymed: added new plot (MHPhi) for wobble mode as described in
1445 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1446
1447 - ganymed: corrects now (correctly?) for the misspointing in
1448 May/April 05
1449
1450 - ganymed: Two new default templates for ganymed.rc are avilable:
1451 ganymed_onoff.rc and ganymed_wobble.rc
1452
1453 - ganymed: The first version of MFMagicCuts has been released
1454
1455 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1456
1457 - ganymed, sponde: There are two new options to determin the number
1458 of bins for the signal region (NumBinsSignal) and the number of
1459 total bins (NumBinsTotal) in the MHThetaSq histogram
1460
1461 - ganymed: optimized palettes for MHDisp
1462
1463 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1464 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1465 sqrt(2) to large
1466
1467 - ganymed: The false source plot (MHDisp) is now based on Disp
1468 and a background model determined in the first loop is
1469 subtracted
1470
1471 - ganymed: MFMagicCuts are now available in the cvs. The correct
1472 solution for the disp ambiguity problem is now calculated using
1473 the third moment. The third moment cut therefor is skipped.
1474
1475 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1476 already determined by the third moment along the major axis and
1477 so its actual sign is aligned along the major axis of the shower.
1478
1479 - ganymed: If starguider data is available it is taken into account
1480 when calculating the source position. This is especially important
1481 for wobble data at high zenith angles and culmination data.
1482
1483 - ganymed: If available the starguider data is taken into account as
1484 good as it is possible without a starguider calibration. To switch
1485 it off add
1486 MPointingDevCalc.MaxAbsDev: -1
1487 to your ganymed.rc
1488
1489 - sponde: the zenith angle distribution is now weighted instead of
1490 choosen by default. This gurantees higher statistics in the highest
1491 and lowest energy bins. To switch this behaviour off use...
1492
1493 - sponde: now automatically displays the energy threshold
1494
1495
1496
1497 *** Version 0.9.3 (2005/06/03)
1498
1499 - general: MMcEvt now derived from MMcEvtBasic which should
1500 have no influence on compatibility with older camera files
1501
1502 - general: Implemented a new option to MReadReports which allows
1503 to force reading of the first event of some trees (eg. Drive-tree)
1504 before any other tree.
1505
1506 - general: Made a fix to MPointingPosCalc which assumes that the
1507 run-type is real-data if Process is called before ReInit, such
1508 that also the very first Drive-events in a run are treated
1509 correctly.
1510
1511 - shoplot now displays the filename in the title bar of the window
1512
1513 - merpp: new options: --auto-time-start --auto-time-stop which
1514 allow to cut updating with slow-control at the start- or
1515 (previousle --auto-time only allowed: and) stop-time of
1516 the run stored in the runheader.
1517
1518 - callisto: changed default of fgFallTimeHiGain in
1519 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1520 already set as default in callisto_Dec04Jan05.rc
1521
1522 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1523 now changes the filename for new weights automatically for
1524 cosmics, MC and for different calibration colors.
1525
1526 - callisto: a problem with the order of some code cause the
1527 name of the weights file in MPedestalY2 to be ignored.
1528 Wrongly the calibration_UV weights were used instead
1529 of the cosmics weights set in callisto.rc.
1530
1531 - callisto: should allow ct1 pulser data when the color is
1532 explicitly set also for pretty new runs
1533
1534 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1535 to introduce an additional scale factor (should be around 1)
1536 to adapt for slight deviations in different extractors from
1537 the MC calibration. For MC calibrations the scale factor
1538 is fixed to 1
1539
1540 - callisto: MFCosmics should handle very high signals a bit
1541 more accurate now
1542
1543 - callisto: when calculating the mean pedestal rms for different
1544 pixel sizes or sectors also kUnsuitableEvt is now taken into
1545 account - not only kUnsuitableRun
1546
1547 - callisto: '-raw' option is now the default
1548
1549 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1550 This has the advantage that mean values in the calibration (eg
1551 arrival times) are calculated more accuratly.
1552
1553 - callisto: In the resource file callisto_Dec04Jan05.rc
1554 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1555
1556 - callisto: new Hi-/Lo-Gain intercalibration constants
1557 hilocalib_sp1.root and hilocalib_sp1_mc.root
1558
1559 - callisto: changed default for MJPedestalY2.MaxEvents
1560 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1561
1562 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1563 has changed from 9.0 to 6.0. This is necessary to exclude two very
1564 ringing pixels in September which - when kept - destroy the image
1565 cleaning around them (Markus G.)
1566
1567 - callisto: (!) The Muon analysis of all data taken so far has
1568 suggested that different extractors give slightly different
1569 absolute results after calibration, due to there different
1570 handling of the calibration- and cosmics pulse shape. Although
1571 the over all calibration seems to be a bit to pesimistic (or
1572 the MC seems to be a little bit - 3-5% - too much attenuated).
1573 There for correction factors have been introduced which correct
1574 the calibration constants by
1575 0.956937799 for Digital Filter (callisto.rc)
1576 and
1577 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1578 calibration. The main advantage is, that both data types can
1579 be easily analysed together and compared to the same MC sample.
1580 The factors are choosen such, that the reference is now a
1581 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1582
1583 - star: fixed a bug which caused the first bin of the histograms
1584 vs time to disapear in PostProcess. This gave wrong results
1585 on the screen. The output and all following programs not
1586 directly accessing the histograms haven't been affected
1587
1588 - star, ganymed: Made sure that always the first Drive-tree event
1589 is read and Processed before the first data event was read.
1590
1591 - ganymed: implemented the possibility to replace the standard
1592 false source plot with a different one. For example: If
1593 you want to use a Disp based FS plot use the resource:
1594 NameHistFS: MHDisp
1595 For details about the requirements of these plots look
1596 at the corresponding classes
1597
1598 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1599 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1600 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1601 case MAlphaFitter is setup correctly. For On-Only optimization
1602 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1603 RunOn() instead of Run(). For energy estimation MJOptimize
1604 has been replaced by MJOptimizeEnergy
1605
1606 - sponde: The input MC spectrum can now be weighted to fake a
1607 different spectrum. This is done via MMcSpectrumWeight. For
1608 more details see the class description and sponde.rc
1609
1610 - sponde: The paremeter comparsion plots are not scaled by
1611 their entries anymore. Instead the MC plot is scaled by using
1612 the result spectrum of the analysis. If the input MC spectrum
1613 and the result spectrum has different slopes the absolut
1614 normalization is normally wrong.
1615
1616
1617
1618 *** Version 0.9.2 (2005/05/20)
1619
1620 - general: Changed the default paths for calibrated data and image
1621 files. (The implemented access to these files doesn't yet exist)
1622
1623 - general: support for MRunIter has been removed from the job classes
1624 (use the setter functions of MSeqeunce instead)
1625
1626 - general: ProcessFile has been renamed to Process in all job classes,
1627 because ProcessFile is missleading
1628
1629 - general: The storage of the palette in MHCamera is now possible
1630
1631 - general: new bits describing unsuitable and unreliable pixels have
1632 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1633 kDeadPedestalRms, kFluctuatingArrivalTimes
1634
1635 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1636 versions newer than V200404070
1637
1638 - general: support for cc file versions newer than V200504130. Added
1639 support for active loads (MCameraActiveLoad) and central pixel
1640 (MCameraCentralPixel)
1641
1642 - general: added new histograms for image parameters versus size
1643 (MHVsSize)
1644
1645 - general: The eventloop now automatically calls PrintStatistics
1646
1647 - Status Display: Improved support for printing:
1648 + A default can now be set in .rootrc (for more details see
1649 MStatusDisplay::PrintPS)
1650 + A print dialog is opened so that printer and command line
1651 can be canged
1652
1653 - showlog: improved such that it handles different verbosity levels
1654 more accurate now. This mean you can suppress output when
1655 using showlog.
1656
1657 - showplot: improved
1658 + The new graphics formats have been implemented
1659 (pdf, svg, png, jpg and xpm)
1660 + Implemented an interface for printing. Because you can change
1661 the printing command from the command line you can use all
1662 the nice postscript tool. To print a booklet for example call:
1663 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1664 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1665 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1666
1667 - callisto: fixed a bug in the recognition of the calibration bit
1668 pattern. Concerns only intensity calibration. (The strength of the
1669 intensity has been updated in some cases)
1670
1671 - callisto: add a filter against PIN Diode events when running over
1672 calibration runs since some of the recent calibration runs have
1673 been taken with Pin Diode.
1674
1675 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1676 39943, 44833 in the calibration (MCalibColorSet)
1677
1678 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1679 been set to 1e-18 in callisto_Dec04_Jan05.rc
1680
1681 - callisto: in callisto_Dec04Jan05.rc: set value for
1682 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1683 statistics for the calculation of the mean pulse time
1684 of the cosmisc
1685
1686 - callisto: the charge limit in the calibration has been raised
1687 from 2.5 to 4.5
1688
1689 - callisto: new setup read from callisto.rc
1690 + MCalibCalcFromPast.fNumEventsDump
1691 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1692 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1693
1694 - callisto: MExtractTimeAndChargeSpline extractor:
1695 + The integration ranges were shifted by 0.2 FADC slices to the right.
1696 + unreliable handling of floating point values caused different
1697 results on different platform or with different compiler options:
1698 The new algorithm is numerically exact and more accurate because
1699 it doesn't calculate the integration position by multiple times
1700 adding the step-size (which results in numerical uncertanties
1701 exspecially if multiplied with large numbers)
1702 + A lot of fixes have been introduced which effects integrating the
1703 spline at the edges of the valid range. In this case any memory
1704 was randomly accessed. This behaviour can be tested replacing
1705 all MArrayF by TArrayF which perform a range check (but of course
1706 they are a lot slower)
1707 ! No result obtained with the Spline before can be trusted! Due to
1708 random memory access it might by completely random!
1709
1710 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1711 + extraction range in the high gain to 4.
1712 + weights file to cosmics_weights46.dat
1713
1714 - callisto:
1715 + introduce the check for fluctuating arrival times.
1716 + set charge limit to from 2.5 to 4.5
1717 + introduce asymmetric exclusion due to "deviating number of phes":
1718 Default: -9.0 +4.5
1719 + make deviating number of phes unsuitable (see David's findings).
1720
1721 - callisto: fixed the display of unsuitable pixels. The old change
1722 to a real profile in MHCamera broke it.
1723
1724 - callisto: The cosmics filter is used in MJCalibration now
1725 independant of the pulser color (formaly it was used only for
1726 CT1-pulser data). The threshold of number of max empty pixels
1727 has been raised from 2% to 5% in MJCalibration. The maximum
1728 fraction of rejected event is 50% otherwise the calibration has
1729 failed. The filter now ignores unsuitable pixels.
1730 Setup the filter from callisto.rc using "ContCosmics"
1731 (see MFCosmics::ReadEnv)
1732
1733 - callisto: changed default for fgOffsetFromLogain back
1734 from -2.8 to -1.8 in digital filter.
1735
1736 - callisto: for the common extractors
1737 + MExtractFixedWindow
1738 * MExtractTimeAndChargeSlidingWindow
1739 * MExtractTimeAndChargeSpline
1740 * MExtractTimeAndChargeDigitalFilter
1741 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1742 and fResolutionPerPheLoGain
1743
1744 - callisto: Updated the hi-/lo-gain intercalibration constants
1745 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1746 hilocalib_df6.root
1747
1748 - callisto: The default lo-gain extraction window for the
1749 MExtractTimeAndChargeSlidingWindow extractor has been increased
1750 from 6 to 8 to take the stretch of the pusle into account
1751
1752 - callisto (!!!): fixed an important bug in the setting of the
1753 incoming pedestal pointer to the signal extractor extracting
1754 pedestals. This bug caused the pedestals not to be subtracted
1755 correctly in the calibration afterwards. The effect was about 10%
1756 too high conversion factors for the digital filter and the spline
1757 and more than 40% for the sliding window.
1758 The bug existed since end of February! (Markus G.)
1759
1760 - star: added muon support to star. A new tab "MHMuonPar" is
1761 displayed. The lower right plot is an estimate of the point spread
1762 function. A reference value is displayed. To get the real PSF
1763 you must compare with MC. The setup for the muon analysis
1764 is done in star.rc. More informations can be found in
1765 MHSingleMuon and MHCalibParCalc
1766
1767 - star: The weather data is now displayed in star
1768
1769 - star: MEventRateCalc handles the calculation of the event rate more
1770 accurate now in case of the start of a new run inside a sequence
1771
1772 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1773 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1774 changed only minimally
1775
1776 - ganymed: (MJCut and MJOptimize) now displayes the number of
1777 excess events versus size. The energy estimation is done in
1778 MJSpectrum (sponde)
1779
1780 - ganymed: got support for using other variables than Alpha, eg. Theta.
1781 Therefor you need a class deriving from MHAlpha which supports
1782 this variable (one is already existing: MHTheta, which is now the
1783 default in ganymed). It is setup through ganymed.rc
1784
1785 - added a full featured spectrum program (sponde) which reads
1786 ganymed output and monte carlos and compiles a spectrum
1787
1788
1789
1790 *** Version 0.9.1 (2005/04/14)
1791
1792 - Fix bug on the arrival time reconstruction when using Digital
1793 Filter (in some marginal cases (10%) times were reconstructed shifted
1794 by 0.2 slices)
1795
1796 - all executables now return 2 where in previous versions -1 has
1797 been returned (gave problems with shell-scripts)
1798
1799 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1800 also done with a intercalibration input file
1801
1802 - a bug in the time fine adjustment of the digital filter has been fixed
1803
1804 - a lot of small fixes to calling TPad::Divide with a margin==0
1805
1806 - MStatusDisplay now shows the memory usage
1807
1808 - added a memory leak statistic after the eventloop
1809
1810 - MHadronness replaced by MParameterD
1811
1812 - MEnergyEst replaced by MParameterD
1813
1814 - wobble mode can now be switched on from the data-set
1815
1816 - switched on bad pixel detection for a pedestal level
1817 which is more than 5 times the variance
1818
1819 - Fixed default paths to be correct for the new data center
1820
1821 - Fixed handling of drive data. The pointing position in now
1822 copied to MPointingPos inside star for real and MC events
1823
1824 - made sure, that the sequences in a dataset are sorted by
1825 their number to ensure the correct synchronization
1826
1827 - added all resource files necessary to handle spline extraction
1828 of signal for the late 2004 and the early 2005 data
1829
1830 - update the reference lines for the december data
1831
1832 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1833 This is important for the Dec. and Jan. data where the calibration
1834 pulse position changes much.
1835
1836 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1837 filter. This corrects only an defective extraction of the MC at
1838 low-gain signals lower than 90 phes.
1839
1840 - fixed some slowdown in calibrating data with interleaved events from
1841 Jan and Dec. As a workaround made the pretty palette the default.
1842 The inverse Deep Blue Sea has a bug which slows down long calibration
1843 runs a lot.
1844
1845 - implemented new values from new starguider report as defined
1846 in TDAS00-07 V7.1 (eg SkyBrighness)
1847
1848 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1849 in starguider report (If you merpp the same reports with this version
1850 you'll get the correct units (arcmin) but a different result
1851 than with old versions (wrong units))
1852
1853 - Now the status display can also write PNG, JPEG and XPM (other file
1854 formats are still unsupported by root)
1855
1856 - added a lot of scripts and macros in directory datacenter used
1857 for automatic processing
1858
1859
1860
1861 *** Version 0.9 (2005/03/23)
1862
1863 - Calibration is now done autmatically into photo-electrons like
1864 decided by the Collaboration Board
1865
1866 - Reference lines in the display can be read from resource file
1867
1868 - Interlaced calibration events can be handled by callisto
1869
1870 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1871 and applied in callisto.
1872
1873 - class MJCalibTest can be called by callisto
1874
1875 - callisto can now run with three data types: rawdata, rootdata, MC
1876
1877 - added two classes mreport/MReportStarguider.cc and
1878 mreport/MReportStarguider.h for implementing starguider-data
1879
1880 - the output of merpp-update now contains starguider information:
1881 MReportStarguider and MTimeStarguider
1882
1883 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1884 values were lower than they should. This was more visible for high
1885 energy (Size) events.
1886
1887 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1888
1889 - added a new loop to callisto to support the correct extraction of
1890 the pedestal and pedestal rms through the signal extractor
1891
1892 - added class to perform fourier tranformation of a hexagonal structure
1893 (MHexagonalFT)
1894
1895 - added class to perform fourier tranformation of a hexagonal structure
1896 in a tasklist (MHexagonalFTCalc) example: hft.C
1897
1898 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1899 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1900 small pixels, example: extendcam.C
1901
1902 - added possibility to write data to memory (TTree) using MWriteRootFile
1903
1904 - added possibility to read a TTree stored only in memory by MReadTree
1905
1906 - new classes to deal with the interleaved calibration events:
1907 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1908
1909 - implemented filters to callisto to skip calibration events
1910
1911 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1912 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1913 the slices by statistics
1914 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1915 signal extractor without randomization
1916 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1917 with the signal extractor with randomization (extraction window is
1918 randomly fixed)
1919 The three kind of pedestal is not yet implemented (for speed reasons) as
1920 long as nobody really needs it:
1921 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1922 extracted with the signal extractor with randomization
1923
1924 - callisto now finds the pulse position in the data automatically
1925
1926 - implemented data reduction in calibrated data by reducing the precision
1927 of the stored floating point values (pedestal, rms and signal) to
1928 roughly 0.5%
1929
1930 - fixed showplot to make file format conversion (eg. converting a
1931 status display stored in a root file into a postscript file) in
1932 batch mode possible:
1933 showplot -b --save-as-ps[=outfile.ps] infile.root
1934
1935 - Allow class names as part of filter rules, eg
1936 (MFSupercuts) && (MHillas.fSize>100)
1937
1938 - fixed a lot of stuff to allow all programs to process MonteCarlo
1939 camera files.
1940
1941 - enhanced possibility to debug reading of resource file
1942
1943 - MDataChain should handle priorities of operator more
1944 accurate now
1945
1946 - completely revised the container in which the signal is stored
1947 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1948 * the new implementation is faster and
1949 * needs less storage space
1950
1951 - FIRST version which can process Monte Carlos through the
1952 whole chain of programs (callisto, star, etc)
1953
1954 - implemented new image parameters for the border length of
1955 the shower image (MNewImagePar2)
1956
1957 - implemented wobble-mode in ganymed
1958
1959 - new class (MJOptimize) taking care of all optimization processes
1960
1961
1962
1963 *** Version 0.8.6 (2004/10/05)
1964
1965 - New combined signal and time extractor
1966 MExtractTimeAndChargeDigitalFilter
1967
1968 - The Report for the trigger section in the CC run summary has been
1969 updated, and now the IPRs (Individual Pixel Rates) are available.
1970
1971 - new macros for database interaction: filldotrun.C, filldotrbk.C
1972
1973 - added new program which can convert colored output which was redirected
1974 into a file back into colored text (for example to display it with
1975 more): showlog
1976
1977 - added new program to display an MStatusArray of plots (stored with
1978 MStatusDisplay) from a file: showplot
1979
1980 - Added support for Sequences (MSequence). Sequences are blocks of run
1981 files containing the same calibration and belonging to the same
1982 source
1983
1984 - Added a new task (MTaskEnv) which can be used in setup files to switch
1985 between different tasks (for example to choose a signal extractor)
1986
1987 - Implemented automatic file splitting in MWriteRootFile
1988
1989 - After image cleaning an island index is assigned to all used pixels.
1990 The index corresponds to the order of the islands in size.
1991
1992 - added a cleaning which takes signal height _and_ arrival time into
1993 account: probability cleaning (for more details see MImgCleanStd)
1994
1995 - added a cleaning which takes takes the absolute number of photons
1996 times the area ratio as cleaning level
1997 (for more details see MImgCleanStd)
1998
1999 - Changed calculation of image parameters such, that it can be done
2000 for all used pixels or the pixels with a defined island index only
2001
2002 - implemented new image parameters displaying the number of islands,
2003 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2004
2005 - event display in executable changed to support also calibrated files
2006 (done with MJCalibrateSignal)
2007
2008 - added program doing the calibration and the signal extraction
2009 and signal calibration: callisto Most part of the setup is done
2010 by a resource file: callisto.rc
2011
2012 - implemented support for pixels with negative IDs (Raw file format
2013 version 4)
2014
2015 - implemented an new option in merpp (--auto-time) to get the time
2016 range for cc and/or caco data from the run header of the raw data
2017
2018 - New star-program (star and MJStar). Taking calibrated data from
2019 callisto/MJCalibrateSignal as input. The setup is done through
2020 a resource file: star.rc
2021
2022 - Added possibility to setup the eventloop in the mars-executable
2023 Camera Display by a resource file: mars.rc
2024
2025 - The the mars-executable Camera Display can now also read
2026 calibrated data files written by callisto/MJCalibrateSignal
2027
2028 - Added a new class which can calculate the source position in
2029 the camera from a pointing model known to be correct and
2030 the pointing model used for observations (MSrcPosFromModel)
2031
2032 - added a new version of the class calculating the effective on-time
2033 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2034 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2035 MHTimeDiffTheta.
2036
2037 - added the possibility to count how often a signal is above (or
2038 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2039 can replace MHTriggerLvl0)
2040
2041 - added ore convinient ways to set the axis-titles of your histograms
2042 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2043 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2044
2045
2046
2047 *** Version 0.8.5 (2004/08/06)
2048
2049 - new Signal Extractors: MExtractFixedWindowSpline
2050 and MExtractAmplitudeSpline
2051
2052 - implementes interleave in merpp to be able to merpp parts of a file
2053
2054 - implemented force-functionality to merpp
2055
2056 - star display to display star catalogs (MAstroCatalog)
2057
2058 - star display to 'mirror' stars to the camera (MAstroCamera)
2059
2060 - implemented a new cleaning option which allows cleaning scaled with
2061 the real ratio of the rms depending on the pixel size, not only the
2062 square root of the pixelsize (MImgCleanStd, MCameraData)
2063
2064 - removed obsolete MBlind* classes
2065
2066 - Signal extractor taking the AB flag into account implemented (this makes
2067 an odd number of slices for signal extraction possible
2068 (MExtractSignalABcorr)
2069
2070 - implemented a class extracting the pedestal from the raw-data (events)
2071 itself using empty lo-gain (MpedCalcFromLoGain)
2072
2073 - Added mean values to MPedPhotCam
2074
2075 - Added Makefile for Darwin (this OS is NOT officially supported!)
2076
2077
2078
2079 *** Version 0.8.4 (2004/04/19)
2080
2081 - new fast arrival time extractor using cubic splines:
2082 MExtractTimeFastSpline
2083
2084 - implementes multi-argument support in MDataChain
2085 ("pow(a, b)")
2086
2087 - implemented double reference support in MDataChain
2088 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2089
2090 - added support in MF for expressiond like
2091 "MHillas.fWidth<2*<MHillas.fLength"
2092
2093 - MDataChain is now able to support variables like [0], [1], ...
2094 which can be used in fit functions as parameters. The interface
2095 is implemented through the new virtual function
2096 MParContainer::SetVariables
2097
2098 - added new class MArrivalTimeCam/MArrivalTimePix:
2099 Storage containers to hold the ArrivalTime of the camera/pixel
2100
2101 - added new classes for the calibration of relative arrival times:
2102 MCalibrationRelTimePix and MCalibrationRelTimeCam
2103
2104 - added new classes to extract the signal of the blind pixel and the
2105 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2106
2107 - added new classes for the bad-pixels treatment (MBadPixels*)
2108 which are more powerfull than the old ones (MBlindPixel*)
2109 and will replace them.
2110
2111 - added filter against cosmics: MFCosmics
2112
2113 - added new class MArrivalTimeCalc2:
2114 Calculates the arrival time as the signal weighted mean of the time
2115 slices in the maximum window
2116
2117 - added a new macro call pointspreadfucntion.C that fits with a 2D
2118 gaussian the DC spot for an star. It gives you the RMS of
2119 the PSF and the center of the star, very useful for misspointing
2120 studies.
2121
2122 - added support for multi-telescope camera files. Added classes
2123 MStereoCalc and MStereoPar, classes to calculate and store shower
2124 parameters calculated from the data of two telescopes, for the MC
2125 studies regarding the MAGIC clone.
2126
2127 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2128 MC data calibrated in photons instead of ADC counts.
2129
2130 - added three macros to show the calibration and analysis chain of
2131 MC data. The macro starmc.C does both calibration and analysis, producing
2132 an output containing Hillas parameters for each event. The macro
2133 mccalibrate.C does just the calibration and writes out a file containing
2134 pixel information in photons instead of FADC data. The macro starmc2.C
2135 reads in such a file and produces an output with Hillas parameters.
2136
2137 - added MPedPhotCalc to compute pedestals in units of photons, see
2138 macro pedphotcalc.C
2139
2140 - added all class to perform the calibration, see macro calibration.C
2141
2142 - added class MFFT to perform Fast Fourier Transforms
2143
2144 - added class MSimulatedAnnealing to perform simulated annealing
2145 minimizations
2146
2147 - added new macro bootcampstandardanalysis.C which holds the skeleton
2148 of the analysis chain discussed in the december bootcamp.
2149
2150 - added support for DAQ raw data file format V2
2151
2152 - implemented an arbitrary time stamp for the events from raw-data
2153 files with file version<3. It is calculated from the run number,
2154 the date of start and the FADC clock tick from the first module
2155
2156 - implemented the correct decoding of the event time-stamp
2157 coming from the DAQ for raw-data files with file-version>2
2158
2159 - added a new classes storing the pedestals in units of photons:
2160 MPedPhotPix, MPedPhotCam
2161
2162 - added support for DC current files from the camera control
2163
2164 - added support for start- and stop-time when merpping report files
2165
2166 - added MReportCC storing the weather data from the CC-REPORT
2167
2168 - added class to fill trainings and test matrices (MTFillMatrix)
2169
2170 - added a filter performing a software trigger (MFSoftwareTrigger)
2171
2172 - Added classes to perform parts of the standard analysis (Jobs):
2173 + MJPedestals
2174 + MJCalibration
2175 + MJExtractSignal
2176 Note: All of them are preliminary!
2177
2178 - Added Iterator to iterate over files giving only the run-number
2179
2180 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2181 the evolution of a sector vs time
2182
2183
2184
2185 *** Version 0.8.3 (2003/12/05)
2186
2187 - adapted Random Forest classes to allow the use with MC
2188 multi-telescope files which can be produced with the coming
2189 camera version 0.7.
2190
2191 - added classes to read and interprete central control report files
2192 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2193
2194 - enhanced merpp (the executable) to support .raw and .rep files.
2195
2196 - added classes for light calibration (MCalibration* and
2197 MHCalibration*) by Markus Gaug. Further work has to be and will
2198 be done soon.
2199
2200 - Added a preliminary 'synchronizer' (MReadReports) which will
2201 replace MReadMarsFile as soon as it is finished.
2202
2203 - Added a tutorial macro demonstrating how report files are merpped
2204 and how they can be read from the root file in the correct order
2205 of time (readrep.C)
2206
2207 - Added a generalized histogram (similar to MH3) called MVsTime
2208 which allows to plot variables (or rules - MDataChain - of
2209 variables) vs time. For an example have a look at tempvstime.C.
2210
2211 - Changed the name of the event trees:
2212 + Events --> Events
2213 + PedEvents --> Pedestals
2214 + CalEvents --> Calibration
2215
2216 - changed name of MTime in the event trees from MRawEvtTime to MTime
2217
2218 - added displaying the sector indices to the mars event display
2219
2220 - Magic Online Analysis (MOnA) implemented in a first version
2221 (see mona.cc, MOnlineDump and MOnlineDisplay)
2222
2223 - added classes to calculate event rate
2224 (preliminary: MEventRateCalc, MEventRate)
2225
2226 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2227
2228 - added classes dealing with the telescope pointing position (MPointing*)
2229
2230 - implemented the 'final' Mars time stamp based on some experiences with
2231 the new 'Synchonizer'
2232
2233
2234
2235 *** Version 0.8.2 (2003/11/10)
2236
2237 - accelerated standard analysis by a factor of 6-8 ...
2238 + doing precalculations in MGeomCam for the pixel area ratio
2239 + creating a look up table for the single pixels in MCerPhotEvt
2240
2241 - added task to calculates weights in case you want to 'change'
2242 the energy spectrum of a monte carlo file
2243 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2244
2245 - added a new executable star which implements the
2246 star.C macro as precompiled executable. Currently a flexible
2247 setup is not possible, but a 'input card' setup will follow.
2248
2249 - Starting to implement Multi-Telescope-Support based on the
2250 upcomming camera version 0.7. The base for a general support
2251 is implemented and the star-functionality is proven to work.
2252
2253 - Replaced Event-Display in and Camera-Display in the Mars GUI
2254 executable by a more convinient display base on MStatusDisplay.
2255
2256 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2257
2258
2259
2260 *** Version 0.8.1 (2003/10/20)
2261
2262 - added signal subtraction for pure on data by means of fitting
2263 the background in the off region or by performing a combined
2264 signal/background fit. Provides necessary histograms for
2265 obtaining energy spectra and a light curve.
2266
2267 - added classes to perform and study the selection of the
2268 2nd Level Trigger on MC data (example in triglvl2.C macro)
2269
2270 - added pedestal calculation
2271
2272 - implemented "democratic cleaning" (tail cut value proportional
2273 to pixel area) according to Wolfgang's suggestion.
2274
2275 - added Sigmabar treatment (calculation and basic histogramming)
2276
2277 - added basic routines to apply padding
2278
2279 - added first implementation of MARS-based source visibility plotter
2280 (needs to be linked against slalib, preliminary version)
2281
2282 - enhanced functionality of data chains: random numbers, conversion
2283 functions and access to MHMatrix objects
2284
2285 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2286 numbers under certain circumstances (runs with 0 events included)
2287
2288 - fixed a bug in the general filter MF (didn't work on some systems
2289 at all)
2290
2291 - fixed a bug in chaining files, which caused the analysis to crash or
2292 ignore files
2293
2294 - implemented more geometry classes describing the parameters used
2295 to simulate the PMT camera
2296
2297 - added new Monte Carlo classes containing the setup of the different
2298 programs in the MC chain.
2299
2300 - added a (preliminary) general task to evaluate chi-square of a given
2301 parameter in an eventloop.
2302
2303 - first implementation of a container describing the observatory
2304 location (Long, Lat, etc)
2305
2306 - added Random Forest - method for g/h-separation
2307
2308 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2309 (this means, that it is compiling, but not yet fully tested)
2310
2311 - added a new status display which can show the present status
2312 of histograms while an eventloop is running (MStatusDisplay,
2313 an example can be found at status.C)
2314
2315 - reorganized directories:
2316 classes describing the image --> mimage
2317 classes containing Monte Carlo Histograms --> mhistmc
2318 classes for Random Forest method --> mranforest
2319
2320 - added (event-)weights to fill histograms
2321
2322 - colors in logging output to screen
2323
2324 - changes to the Image Parameter declaration:
2325 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2326 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2327 + MHillasExt now derives from MParContainer instead of MHillas
2328 --> Files written with the old definition are more or less unreadable
2329
2330 - reading of reflector files
2331
2332 - display data from reflector files in the camera
2333
2334 - implemented currents (and display them in the camera)
2335
2336 - logarithmic scale in camera
2337
2338 - added class to iterate through directory contents (MDirIter)
2339
2340
2341
2342 *** Version 0.8 (2002/11/18)
2343
2344 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2345
2346 - corrected 48(!) wrong entries in the Next Neighbor table of the
2347 Magic Camera (all in the inner part of the outer ring, mostly
2348 missing a single NN)
2349
2350 - Fixed a bug in the table describing the Next Neighbours of the
2351 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2352 have any neighbour)
2353
2354 - changed trigrate.C: now it calculates the pure NSB triggers from
2355 a camera file (generated with no showers), so there is no need
2356 to introduce them by hand in the BgR array (for more details
2357 please ask Abelardo)
2358
2359 - added MHHadronness (and MHadronness) as a general facility to evaluate
2360 the quality of a gamma-hadron seperation method
2361
2362 - changed MWriteAsciiFile to accept rules (MDataChain)
2363
2364 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2365 must be replaced by calles to MWriteAsciiFile::AddColumn and
2366 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2367 changed.
2368
2369 - Implemented generalized event-matrices (one row per event)
2370 (MHMatrix)
2371
2372 - implemented the one dimensional composite probabilities
2373 (MHCompProb, MCompProbCalc, comprob.C)
2374
2375 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2376 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2377
2378 - Added a camera display displaying the pixel numbers to the
2379 event display gui.
2380
2381 - Added Monte Carlo Informations to event display gui
2382
2383 - Changed the camera display to display the pixel numbering
2384
2385 - Added three buttons to the camera display to change the palette
2386
2387 - Added the number of used and core pixels after image cleaning
2388 to MHillas
2389
2390 - Changed the algorithm used in MHillas according to TDAS 02-03
2391
2392 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2393
2394 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2395
2396 - Added fCosDeltaAlpha to MHillasSrc
2397
2398 - The numbers of photons used to calculate fConc and fConc1 in
2399 MHillasExt are now scaled with the pixel size, so that one get
2400 a four times smaller value for the bigger pixels in the outer ring.
2401
2402 - added new task to smooth the camera contents (MCameraSmooth)
2403
2404 - added possibility to use interpolated pixel values for blind pixels
2405 instead of removing it completely from the analysis
2406
2407 - Implemented the possibility to save the whole eventloop with
2408 its setup to a file. This information can be read and from
2409 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2410 and MEvtLoop::MakeMacro. If you find something not working, please
2411 report - this stuff is still in a beta phase.
2412
2413 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2414 file having crab starfield, but also for all following files - fixed
2415
2416 - MTaskList::PrintStatistics can now be instructud to print also the
2417 title, too: use PrintStatistics(0, kTRUE)
2418
2419 - Changed the image cleaning so that pixels with to many 'used'
2420 neighbors are left used (to get rid of 'holes' in events)
2421
2422 - Introduced more output to the camera displays
2423
2424 - Added an array of histograms (eg one hist per run), MHArray
2425
2426 - Added a _preliminary_ version of the reader for CT1 PreProc files
2427 (MCT1ReadPreProc)
2428
2429 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2430 (thanks to Raquel)
2431
2432 - added the first energy estimator (MEnergyEstParam, estimate.C,
2433 estfit.C) using a parametrization
2434
2435 - Added some new Monte Carlo paremeter containers used to store
2436 setup information from the MC chain (MMcConfigRunHeader,
2437 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2438
2439
2440
2441 *** Version 0.7 (2002/04/30)
2442
2443 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2444 the pedestal mean value was saved incorrectly. For files from
2445 this versions we substract 0.5 from the pedestal mean.
2446 WARNING: This may effect your results, so don't wonder...
2447
2448 - First implementation of an algorithm using only triggered events
2449 for the collection area calculation
2450
2451 - Ascii Output can now also be used for parameter containers which
2452 doesn't overload MParCointainer::AsciiWrite
2453
2454 - The Ascii Output is now also capable of writing single data members
2455 of one container
2456
2457 - You are now able to change the order of the values written to the
2458 ascii file
2459
2460 - You can now specify a conversion factor for each data member written
2461 to an ascii file. This may be usefull to change the units of the
2462 data member (eg. degrees instead of millimeters in case of the
2463 hillas parameters)
2464
2465 - Replaced old MHillas by a new structure which allows you to extend
2466 the parameters stored in MHillas very easily:
2467 see MHillas and MHillasExt
2468
2469 - Added classes to handle source dependancy of image parameters:
2470 see MHillasSrc
2471
2472 - Added container (MBinning) to have a standard input for the binning
2473 in different histograms (eg. the Energy bins should be the same in
2474 all histograms)
2475
2476 - Changed Hillas histograms from mm to deg
2477
2478 - Added the flexible binning to the hillas histograms
2479
2480 - Added a filter for the alpha parameter (MFAlpha)
2481
2482 - It is now possible to write single data members of a class object to
2483 an output stream instead of the whole container only
2484
2485 - Added a generalized filter for a data member:
2486 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2487
2488 - Added a generalized Filter parser for more difficult filter rules
2489 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2490
2491 - Added new Monte Carlo histograms:
2492 MHMcEnergyImpact and MHMcEfficiency
2493
2494 - Added many new histograms needed for the flux calculation.
2495
2496 - Added a generalized histograms which can fill and show up to three
2497 data members in either a one-, two- or three-dimensional histogram, eg:
2498 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2499
2500 - Added:
2501 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2502 * calculation of <Theta> as a function of time (MHThetabarTime)
2503 they are needed in the flux calculation in
2504 order to select for a given bin in Theta (or time) the appropriate
2505 effective collection area, which is assumed to be given as a function
2506 of Theta and the true energy
2507
2508 - Added calculation of the migration matrix in the energy
2509 (MHMcEnergyMigration):
2510 the migration matrix describes the migration from the true (E_true)
2511 to the estimated energy (E_est); it is needed to determine the
2512 distribution of E_true from the measured distribution of E_est
2513 by unfolding
2514
2515 - changed the color palette in the camera display to DeapSea.
2516
2517
2518
2519 *** Version 0.6 (2002/01/15)
2520
2521 - Introduce the option of disable pixels (MBlindPixels and
2522 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2523 able to deal with Star Field NSB.
2524
2525 - Fixed a bug in the pedestals substraction
2526
2527 - Introduced verbosity levels
2528
2529 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2530
2531 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2532 work correctly (thanks to Abelardo)
2533
2534 - Introduced correct treatment of the diffuse Night Sky Background
2535 and NSB (MMcPedestalNSB)
2536
2537 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2538
2539 - Introduced MMcRunHeaders which contains monte carlo run informations
2540
2541 - Added a 'Print'-Task (MPrint) which calls the Print function
2542 of a parameter container for each event
2543
2544 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2545
2546 - changes to be more efficient with root 3.02/06
2547
2548 - root 3.02/06 fixes:
2549 + the memory leak when reading MRawEvtData
2550 + loosing more time than necessary to update the progress bar
2551
2552 - MWriteAsciiFile is now capable of writing more than one container
2553 in a line. For example: To be able to write Monte Carlo and
2554 Hillas values (energy and alpha) in one line.
2555
2556
2557
2558 *** Version 0.5 (2001/11/06)
2559
2560 - Added new GUI functionality (Analysis)
2561
2562 - Added a camera display to be able to display events in the camera
2563 together with the calculated hillas ellipse
2564
2565 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2566 object at any state of the analysis, so that the output are several
2567 states
2568
2569 - Fixed a bug in the collection area error calculation
2570 (Thanks to Ciro and Abelardo)
2571
2572 - Fixed a bug which causes merpp to crash in some environments
2573
2574 - Implemented auto enabling scheme for Branches to speed up reading
2575 a lot (see MReadTree and MTask)
2576
2577 - Fixed a bug in the Histogram classes which caused histograms to
2578 be written to a file by MWriteRootFile without request
2579
2580 - changed the object I/O from the old stylish root I/O to the new
2581 'auto evolution scheme' This was done only for classes which are not
2582 yet used in Monte Carlo files, so that these files are still readable.
2583
2584 - Added support for a progress bar in MEvtLoop and MReadTree
2585 (see the Analysis Window in Mars for an example)
2586
2587 - Fixed a bug in the package creation which disturbed the conversion
2588 between a mars version unpacked from a tar file and the repository.
2589
2590 - Changed the code to writer merpped (converted into root format)
2591 raw files, to get faster (around 10%)
2592
2593
2594
2595 *** Version 0.4 (2001/09/20)
2596
2597 - This release is made to compile on a root version >= 3.00
2598
2599 - Fixed a bug which causes MReadTree to read the first file only
2600
2601 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2602
2603 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2604
2605 - Added a task to write several container to a root file (MWriteRootFile)
2606
2607 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2608
2609 - Added calculation of the collection area (MMcCollectionAreaCalc)
2610
2611 - fixed some bugs in the Hillas calculation
2612
2613 - added filters to be able to control the task execution dependent on
2614 a parameter (for example: the number of level 1 triggers in a MC-file)
2615
2616
2617
2618 *** Version 0.3 (2001/04/23)
2619
2620 - Many demo macros added
2621
2622 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2623
2624 - Hillas Calculation added
2625
2626 - Standard image cleaning available
2627
2628 - MReadTree is now able to handle more than one file
2629 (Remark: of the same structure)
2630
2631 - Now we are able to display events in a first version of the
2632 Camera event display. To do this we must run the macro
2633 "macros/readCT1.C" to read data from CT1.
2634
2635
2636
2637 *** Version 0.2 (2001/01/24)
2638
2639 - First Implementation of a Gui to read the raw data. Start the
2640 gui with the command mars.
2641
2642
2643
2644 *** Version 0.1 (2000/12/20)
2645
2646 - First official release 0.1
2647
2648 - Changes:
2649
2650 + changed calling style of MRawPixelIterator from do...while to
2651 while-loop
Note: See TracBrowser for help on using the repository browser.