source: trunk/MagicSoft/Mars/NEWS@ 8734

Last change on this file since 8734 was 8734, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 110.7 KB
Line 
1 -*-*- END -*-*-
2
3 *** Version 2.0 (2007/09/03)
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Resource file now allow an Include-Resource, i.e. you can
11 read a resource file with default settings, include it in your
12 resource file and overwrite the settings in your file. More than
13 one include file is allowed. Inclusions can be iterative.
14 Include: mydefaults.rc yourdefaults.rc
15 The resources in the first file have higher priority than the
16 second file.
17
18 - general: Now the output files (calib*.root, etc) also contain the
19 resource file (to check it open it in the TBrowser and choose Print()
20 from the context menu)
21
22 - general: Dataset files now allow to overwrite the default path
23 to search for sequence and data files. Note, that the program
24 option and individual resources will overwrite it. For example:
25 SequencePath: /magic/montecarlo/sequences
26 DataPath: /magic/montecarlo/star
27
28 - general: Fixed a problem with variables in MDataPhrase. It seems
29 that only optimdisp (didn't work) was effected.
30
31 - general: Some improvements to the optim and train processing. For
32 example the ststud window now got a proper title.
33
34 - general: The "Status Display: " was removed from the window title
35 within an Eventloop.
36
37 - general: added a new flexible histogram-class (MHn) which can be used
38 for example in testing after optimizations or training to produce
39 user defined histograms.
40
41 - general: The Random Forest now allows attaching an evaluation
42 function which is applied to its output. This allows to train
43 on whatever you like (eg. train on log10(energy), but return
44 energy)
45
46 - general: TheRandom Forest training of energy (trainenergy.c) and
47 disp (traindisp.C) has been improved by more graphical output to
48 judge the result.
49
50 - general: The training of energy (trainenergy.C) has been improved
51 a lot by training on a different quantity than energy. It gives
52 a result which is highly independant of the source spectrum
53 and shows lower bias than all other options.
54
55 - general: Dataset files are allowed to contain collections of
56 datasets. For more details see the class reference of MDataSet.
57
58 - general: The default WobbleMode in a datset file now (if not
59 overwritten) is "auto", i.e. wobble mode is set if the dataset
60 doesn't contain off-sequences.
61
62 - merpp: Merpp can read file format version 9 now. Please realize
63 that for file format version 9 the extraction range is different
64 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
65 the first and last 15 slices have been removed from all MUX data.
66
67 - mars: Similar to writing movies you can now select events which
68 should be displayed in your display. Therefore add the following
69 lines to your mars.rc:
70 MFEvtNumber.FileName: ganymed00223552.root
71 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
72 The input file can be a ganymed-file after (ganymed*.root) or
73 before (ganymed*-summary.root) file. For example to select all events
74 from your on sample after cuts (excluding the ThetaSq cut) use
75 MFEvtNumber.Selector: DataType.fVal>0.5
76 To show all events from your on-sample after quality cuts
77 use the summary file instead.
78
79 - mars: new ways to call mars are implemented. Instead
80 of calling
81 mars filename.root
82 you can now also use
83 mars sequence.txt
84 or
85 mars sequence.txt inputpath
86 or replace sequence.txt by the sequence number if the default
87 sequence file should be used.
88
89 - mars: The default size has been increased
90
91 - mars: There are two new heckboxes which allow to switch off
92 the calculated image parameters
93
94 - callisto: was broken for MCs... fixed.
95
96 - callisto: improved calculation of spline coefficients a lot. This
97 leads to a further improvement of the event rate calibrating MUX
98 data of about 15% (175evt/s instead of 150evt/s)
99
100 - callisto: finally the raw data we read is now real 16bit (with
101 10bit precision) for MUX data and not a stripped 8bit number
102 anymore. Due to scaling of the numbers (without precision loss
103 into an [0-256[ range, the final numbers for pedestal, pedestalrms
104 and extacted signal don't change. However, at all places where
105 raw data is directly accessed (eg. saturation and variation
106 limits in the signal- and pedestal-extraction) the numbers
107 refer still to the data's 16bit range.
108
109 - callisto: The maximum arrival time difference used in the bad
110 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
111 for both, old FADC and MUX-FADC, data.
112
113 - callisto: Be aware that callisto is now calibrating the arrival time
114 in nanoseconds rather than time slices. Also all following tasks
115 have been changed to assume ns units now. If you star data
116 calibrated with an older version it might be necessary to adapt
117 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
118 to obtain optimal results. The plot in the PulsePos tab
119 will now be in ns, too. This might also mean that the Muon
120 analysis in star might not work as perfect as expected as long
121 as old files read in.
122
123 - callisto: The callibration constants of earlier updates got lost
124 somehow. All constants have been updated.
125
126 - star: The PSF is now determined from the profile of the ArcWidth
127 instead of arcwidth/radius. The old way gave to much weight
128 to the bins with low statistics. The reference lines have been
129 updated.
130
131 - star: For speed reasons events suitable for the muon analysis
132 are now also preselected by fConcCOG<0.1 which seems to be a very
133 good preselector for muons.
134
135 - star: is now calculating a new timing parameter the Slope along
136 the major and minor axis of the shower. Therefore a numerical
137 solution of a line-fit is used. To use MHillasExt.fSlopeLong
138 and MHillasExt.fSlopeTrans don't forget to multiply it with
139 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
140
141 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
142 have been removed from MNewImagePar. They have never been good for
143 anything.
144
145 - star: Implemented a new recursive algorithm which is supposed to be
146 faster. Also implemented new cleaning oiptions, which are:
147 + CleanLevel0:
148 The cleaning level above single core pixels can be kept
149 + KeepIsolatedPixels:
150 Define whether single core pixels should be kept
151 + TimeLevel1:
152 The coincidence window in nanoseconds to single used neighbors
153 + TimeLevel2:
154 The coincidence window in nanoseconds to two used neighbors
155 + PostCleanType:
156 MOde in which a time dependent post cleaning should be applied
157 0: No post cleaning
158 1: Require for each used pixels at least one used neighbor
159 within a time-window of CleanLevel1
160 2: Require for each used pixels at least two used neighbor
161 within a time-window of CleanLevel2
162 3: Require first two and second one used neighbor
163 within a time-window of CleanLevel1 and fCleanLevel2
164 respectively
165 + RecoverIsolatedPixels:
166 - recoveres isolated core pixels if they have a used neighbor
167
168 - mars/star: The new default cleaning is:
169 + CleanLevel1: 6.0
170 + CleanLevel2: 3.0
171 + CleanTime1: 1.75
172 + CleanTime2: 1.75
173 + PostCleanType: 3
174
175 - star/ganymed: The old spark-cuts have been replaced by new ones.
176 These new spark cuts have been cross checked with the sequences
177 84720 (before splitter), 101041 (after splitter) and 223539 (new
178 FADCs). In all cases they seperate pretty well, but of course not
179 perfect. Monte Carlos have suggested to tighten the cuts a little
180 bit further at low sizes. This has been done.
181
182 - ganymed: IMPORTANT - The spark cuts have been changed to match
183 all available data more or less well. This might mean that for
184 YOUR data there are still sparks visible.
185 Whenever you do an analysis you have to make sure that NO sparks
186 survive your cuts!
187
188 - ganymed: The old hadronness and size cuts have gotten new indices
189 (10, 11). The old indices 8 and 9 now mean an additional condition
190 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
191 If you want to switch off this cut just move the line far away enough,
192 e.g. by setting c[9] to -500. Please update your ganymed.rc files
193 accordingly!
194 The unit of c[9] is deg. It is the dist at which your cut will
195 cross the slope==0. The unit of the slope is ns/deg. So if
196 you readin files calibrated with an older Mars-version you
197 have to adapt the default value for c[9] to the FADCs:
198 - Multiply by two for the MUX FADCs (run number > 200.000)
199 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
200 - Multiply by 42 for the meaning of life (run number = 200.000)
201
202 - ganymed: The old Cut0 is now called CutQ and is calculated before
203 the source position is caluclated. If you need a quality cut
204 including source dependant data (be very carefull with this!)
205 you have to use Cut0 instead.
206
207 - ganymed: now properly supports three off regions in wobble mode.
208 It will be the default from now on in ganymed_wobble.rc. To change
209 the number of off-regions use
210 NumOffSourcePositions: 1
211 in your ganymed.rc. Also by default no off-theta cut will be done
212 anymore so that you will get a background level higher than the
213 signal level in your ThetaSq plot for ThetaSq>0.2.
214 Due to this be carefull changing the scaling mode away from
215 "None". You will underestimate your signal if your scale interval
216 is not properly set.
217 (Rem: ThetaSqN is no longer needed)
218
219 - ganymed: is now storing the events of all (on- and off-)
220 source positions even in the case of more than one off-source
221 position. This should allow sponde to work properly and the
222 energy estimation is done correctly in all cases (without any
223 "nearest position" trick)
224
225 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
226 with a real pointing model for the starguider is done, calibrated
227 with more than thousand tpoints taken from this date on.
228
229 - ganymed: was broken for Wobble-MCs... fixed.
230
231 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
232 has changed. Note that your old ganymed.rc will be incompatible
233 with the new algorithms! Please check the ganymed.rc files and
234 the class description of MFMagicCuts for more information.
235 It is recommended at the moment to use identical Disp-Parametrizations
236 for on/off- and wobble-mode. If cuts are optimized only
237 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
238 should be optimized. All other values should be kept as they are.
239 If you want to do an anylsis without timing a parameters, you can
240 switch off the timing cuts by seeting parameter 7 to a very small
241 value (eg. -99). To remove the slope parameter from the disp
242 paremtrization set parameter 8 to 0.
243
244 - ganymed: The distribution of observation time versus zenith
245 angle is now shown for off- AND on-data.
246
247 - ganymed: The contents of the source position plot are no longer
248 averaged, thus a lot of (fake) events between the two wobble
249 positions have disappeared.
250
251 - ganymed: There is a new tab "CutT" it contains the VsSize plots
252 with the CutT, whihc is defined in ganymed.rc, applied. It
253 is resonable to use your theta-cut for it, to see if there is
254 something strange (sparks!) in your signal-region.
255
256 - ganymed: To choose a dataset from a collection in a dataset file
257 use the new command line option "--dataset=12345"
258
259 - optim, sponde: should now properly support three off-regions.
260 Just produce your ganymed summary files with three off-regions.
261 optim and sponde will automatically get all off events from
262 all off-regions from this file. Please do not forget to
263 set the scaling in optimwobble.C properly:
264 fit.SetScaleUser(1./3);
265 it is not yet read in automatically (will follow soon).
266 In the case of fixed Scale you can also use
267 cuts.SetThetaCut(MFMagicCuts::kOn);
268 no off-cut needed.
269 Be carefull in case of three off-regions when switching on
270 scale mode. Make sure that the scale interval is set correctly.
271
272 - sponde: sponde.rc and sponde_onoff.rc are now idetical
273
274 - sponde: the resouce files have been rewritten with a lot of
275 comments and a well working parametrization for an energy estimator
276
277 - sponde: In the estimated energy versus monte carlo energy plot the
278 contents where exchanged.... fixed.
279
280 - sponde: the so called "accurate"-mode has been removed. It didn't
281 give any improvement in accuracy, only decreased execution speed.
282
283 - sponde: the so called "simple"-mode has been removed. It didn't
284 give any improvement in simple.
285
286 - sponde: the so called "refill"-mode has been removed. It was anyhow
287 not implemented.
288
289 - sponde: now checks whether the theta distribution of your on-data
290 and the theta-distribution of your Monte Carlo sample (after
291 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
292 sample is incomplete) execution is stopped. Execution can be forced
293 using the new option --force-theta. Use this option with care!
294
295 - sponde: Proper collection areas can now be constructed also from
296 Monte Carlo samples generated with different maximum impact
297 parameters. Note that in previous version you neither got
298 a warning or failure, nor was there any obvious sign that the
299 collection area was overestimated due to usage of files with
300 different maximum impact parameters.
301
302 - sponde: If MC files with different lower energy limits are used
303 the primary MC spectrum is artificially completed down to the
304 lowest energy used at all. WARNING: that this gives correct
305 collection areas ONLY if none of the events in this region would
306 survive your cuts at all.
307
308 - sponde: the output file now contains more information about
309 the spectrum (eg. the full 2D collection area histogram).
310 Note, that this information can only be written to the file
311 if it is stored automatically via command line argument.
312 If you only store the status display from within the display
313 the information is lost.
314
315 - sponde: added a new tab "Disp". It shows the residual of the disp
316 (Disp-Dist) versus several parameters and it is meant to judge the
317 quality of the disp estimator. In the ideal case the residual is zero
318 and doesn't depend on any variable. The tab is displayed after
319 CutQ and Cut0.
320
321 - sponde: added a new tab "Energy". It shows the residual of the
322 energy (lg(estimated energy)-lg(monte carlo energy)) versus
323 several parameters and it is meant to judge the quality of the
324 energy estimator. In the ideal case the residual is zero
325 and doesn't depend on any variable. In reality even a good estimator
326 can show residuals versus Monte Carlo energy. The tab is displayed
327 after all cuts.
328
329 - sponde: added a new tab "EventDist" showing the unweighted real
330 absolute number of events of your sample after cuts. This tells
331 you how many events with this energy you had in your MC files.
332 The same information you get from the error bars of the weighted
333 histograms, but this is less intuitive.
334
335 - sponde: The spectrum plots now show the crab- and 1553-spectrum
336 for comparison. It is not meant to show these curves in
337 publications, they are only for production.
338
339 - sponde: The OriginalMC tree with the events produced by corsika
340 is now processed only once
341
342 - sponde: Finally fixed most annoying bug, which has effected the
343 last bin of the collection area. It was the problem that binnings
344 of root histograms are from 1 to n (included) but there was a C-like
345 loop in sponde from 0 to n (excluded). Now the loop also includes
346 correctly under- and overflow-bins. The worse thing with this is,
347 that for the events in the highest bin not only the bin-content
348 was wrong, but also the weights applied to these events, which could
349 in pricipal effect also other parts of the distribution (eg. due
350 to energy estimation). Fortunately it effected only a few events
351 in most cases.
352
353
354
355 *** Version 1.2 (2007/05/14)
356
357 - database: The database now has two new values Unsuitable50 and
358 Unsuitable01. They express the number of pixels which are
359 unsuitable for more than 50%, respectively more than 1%, of
360 all calibrated event. It is a more accurate number than the
361 previously used numbers, because they only take the first
362 calibration (ignoring the interleaved calibrations) into account.
363
364 - database: The database now has two other new values UnsuitableMax and
365 DeadMax. They express the maximum number of pixels which were
366 unsuitable, respectively dead, during the sequence. Because
367 of high pedestal rms (cars passing) a few events with very high
368 numbers of unsuitable pixels can happen. Not to suffer from this
369 effect we don't take the highest 0.1% of the numbers into account.
370
371 - general: fixed a bug which caused callisto and star to stop working
372 properly because the callisto output was currupted
373
374 - general: a script called scripts/makemovie has been added which
375 simplified the process of producing several movies from a single
376 sequence with different setup.
377
378 - callisto: Some more code cleanup. Started to remove old obsolete
379 code from cvs.
380
381 - callisto: The extraction of the pedestal with the extractor was
382 not random. It seems that extracting at one position is still biased
383 (for example in the first or last slices we could still suffer from
384 switching noise) Now it is completely random.
385
386 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
387 pedestal files) individual pixels could be skipped due to high
388 variations. This was already the case for the pedestal extraction
389 from the lo-gains since the beginning and properly handled
390 there, but was introduced in the extraction from the pedestal files
391 a while ago. To calculate the average value it was still divided
392 by the number of events procesed not by the number of summands
393 really summed. This let to a pedestal which was a tiny amount too
394 small (for a few piels in the order of 0.1%). This led to an slightly
395 positive offset of the randomly extracted pedestal for a few pixels.
396 I doubt that this has a big effect on the result, because the effect
397 on the individual numbers is quite small. Due to this it is suggested
398 that you rerun your calibration to make sure you are without any
399 avoidable bias.
400
401 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
402 the median rms of the absolute arrival time and expressed in significance
403 levels. This replaces the old meaning of an abolute upper limit. An
404 absolute upper limit doesn't make much sense, because in our data
405 all arrival times are shifted at the same time (in fact it might be
406 a shift of the artificial trigger w.r.t. to the light flash).
407
408 - callisto: Added a new tab "BadPixTm" which shows the time evolution
409 of the number of unsuitable pixels over the whole sequence. This
410 is usefull mainly to judge if an intermediate calibration had
411 problems.
412
413 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
414 of the number of dead pixels over the whole sequence. Dead pixels
415 in this context are unmapped pixels, i.e. pixels which could not
416 be interpolated, and thus are ignored in the further analysis.
417
418 - callisto: It is now possible to use the position of the maximum
419 of the spline as arrival time instead of the leading edge even
420 when using the integral for the signal. Therefor set the extraction
421 type to kIntegralRel ("IntegralRelative") and the relative height
422 ("HeightTm") to -1:
423 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
424 MJPedestalC1.ExtractSignal.HeightTm: -1
425
426
427
428
429 *** Version 1.1 (2007/04/27)
430
431 - general: The new class MGeomCamDwarf contains the camera geometry
432 for our prefered Dwarf camera and can be used to create general
433 geometries of roundish or hexagonal cameras.
434
435 - mars: The default cleaning is now abolute 8.5/4.0.
436
437 - mars: The resource file mars.rc now contains examples for MUX data
438
439 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
440 data containing only 10-bit information is still cooked down to
441 8-bit, by cutting away the lowest 8-bit.
442
443 - merpp: When reading raw data the data is now stored in a single
444 array. The lo-gain array is obsolete. The interface stays the same.
445
446 - callisto: To process the new MUX data use the resource file
447 callisto_mux.rc
448
449 - callisto: The -root and -raw options to read merpped raw data have
450 been removed
451
452 - callisto: If the -mc option is given the sequence-name can now be
453 replaced by the MC sequence number
454
455 - callisto: If the sequence file contains "MonteCarlo: Yes" the
456 -mc option can now be omitted
457
458 - callisto: Started further simplification by removing obsolete
459 dependancies on MCalibIntensity*Cams.
460
461 - callisto: removed unsused intensity calibration from MJCalibration
462 for further simplification
463
464 - callisto: for simplification removed references to
465 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
466 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
467 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
468 (this should at minimum change nothing at all, and at maximum
469 improve thing if these containers where somewhere not handled
470 properly)
471
472 - callisto: Added the option to write an event movie. Please use
473 this option with care (huge files) but exessively to understand
474 our events. For further documentation please refer to the
475 IACT wiki
476 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
477
478 - callisto: Improved binning for the pulse position check histogram
479
480 - callisto: The code calculating the pulse position checknow takes
481 the pedestal into account
482
483 - callisto: The arrival time is now stored with full precision this
484 helps to get rid of artefacts in histograms. For the signal this
485 is not necessray because it is displayed in log-scale anyhow
486
487 - callisto: Fixed a problem with internal exclusions. Pixels which
488 have once been marked as unsuitable didn't get the necessary
489 histograms filled anymore to be rechecked with each interleaved
490 calibration.
491
492 - callisto: The relative arrival time resolution (the rms of the
493 relative arrival time offset) is now checked against its
494 median and the median deviation, instead of the average
495 plus an absolute offset.
496
497 - callisto: The relative arrival time offset is now calculated
498 w.r.t. its median not w.r.t. to an artificial reference pixel.
499
500 - callisto: The relative time calibration now marks pixels with
501 outlaying offset as unsuitable
502
503 - callisto: The interleaved relative time calibration has been switched
504 on. The advantage is that pixels which are marked as outliers
505 now can recover. An improvement over time is not expected, because
506 the relative time calibration seems stable.
507
508 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
509 option can now be omitted.
510
511 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
512 or the option "-mc" is specified as default the monte carlo datacenter
513 paths (/magic/montecarlo/...) are used if not overwritten in the
514 dataset file.
515
516 - ganymed: The output files now contain run- and event-number for all
517 events, accessible as RunNumber.fVal and EvtNumber.fVal
518
519 - ganymed: Added a plot showing the source position in the camera also
520 for wobble mode
521
522 - ganymed: In addition to the existing task which can be setup to
523 be executed after Cut1 a final task called "EstimateEnergy"
524 has been added, executed before writing the final output
525 (ganymed00000000.root). The task setup in all three cases
526 can be choosen individually. (For all three(!) cases you
527 can for example choose MRanForestCalc. For examples see all
528 sponde*.rc and all ganymed*rc)
529
530 - ganymed: If a container "MEstimatedEnergy" is found in the
531 parameter list (eg. because it was setup by MEstimateEnergy)
532 it will be written to the output file.
533
534
535
536 *** Version 1.0 (2007/02/16)
537
538 - database: Website to plot values from the database has been added.
539
540 - database: The rate of spark events as found by star is now kept
541 and the rate after cleaning is now with spark events subtracted
542
543 - general: The changes to the interpretation of phrases lead to
544 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
545
546 - general: Added example files how you can create your own calendar
547 (eg. as christmas present) with Mars. Just run
548 root macros/tutorials/calendar.C
549
550 - general: Added a possibility to display grouped data in the plotdb.C
551 macro (and similar macros). This allows to plot hourly, nightly,
552 weekly, monthly and yearly averages.
553 For more details see the plotall function of the macro
554
555 - general: fixed the error display of the camera display. It showed
556 wrong results.
557
558 - general: fixed a memory leak when reading many MStatusDisplays
559
560 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
561 between a spherical and a parabolic mirror
562
563 - callisto: We have a new pulse position check which takes the properties
564 of the extractor automatically into account. So no need to set
565 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
566 left is done. If possible the lo-gain extraction start and hi-gain
567 extraction end is changed accordingly. If no proper extraction range
568 can be set (hi-gain too much to the left) an error is raised.
569
570 - callisto: New swapped pixels have been found and corrected
571
572 - callisto: Redone the signal extraction this includes:
573 + Unified the algorithms to extract the pedestal for all pedestal
574 extractions done
575 + Unification of hi- and lo-gain into one array
576 + Unification of hi- and lo-gain extraction for Spline and
577 Digital Filter (means now exactly the same algorithm is used,
578 not a copy-and-pasted one)
579 + Store pedestal subtracted data in a common place
580 + Improved extraction algorithms. If the algorithms search a
581 maximum but don't find one they don't return the maximum anymore
582 + Improved the extraction such that a information for signal
583 and time which is consistent is returned
584 + replaced the numerical spline with a (not slower) analytical
585 solution
586 + Lowered the saturation limit from 250 to 245 to make sure that
587 we are far away in all pixels from problems with the clock-noise
588 + The start of the lo-gain extraction is calculated from the hi-gain
589 arrival time. In case of saturation an estimation is used.
590 + the hi-gain window was extended to slice 16. This allows extraction
591 of very late pulses in single pixels or of huge hadron showers.
592 + Now uses the lo-gain extraction range for pedestal extraction,
593 not the hi-gain range in the lo-gain
594
595 - callisto: New hi-/lo-gain calibration constants have been produced
596 for all periods from the statistic of the whole period. They are
597 now used automatically depending on the periods. The old constants
598 where deviation in avarega about 2%-3%. The constants are very
599 stable from period to period (<<1%) except for exchanged channels.
600 In a few cases the constants used so far were off by 1%-2% (maybe
601 temperature effects?)
602
603 - callisto: To gain obsolete space we do not write the
604 MPedestalFundamental anymore. Also calibration and bad pixel
605 treatment is not done for it anymore because it has never been used.
606
607 - callisto: Fixed a bug in the seuqence handling which caused the
608 light condition to be ignored
609
610 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
611 basically the same as "Cleaned" but the distribution devided into
612 the events fullfilling a spark cut or being rejected by it.
613 This cut can be changed from star.rc (see example inside) by
614 the "SparkCut" directive
615
616 - star: Star displays now the average individual pixel-rate (IPR) versus
617 time and the average discriminator threshold (DT) of all pixels.
618
619 - optim: fixed a problem with the optim-macros which was due to a bug
620 in the new phrase parsing
621
622 - ganymed: To get a nice FalseSource plot (instead of the all-information
623 debug plot displayed as a standard plot) use the context menu
624 somewhere between the two upper plots, click on "DrawNicePlot"
625 and enjoy the result. (It is the same context menu which contains
626 the other options)
627 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
628
629 - ganymed/optim/train: The cut program, trainings- and optimization
630 macros could run with less files found than expected from the
631 sequence-files. No the execution is stopped in this case.
632
633 - ganymed: now stores the dataset in the output file with all information
634 contained (as sequence number, sequence path, data path) so that the
635 used dataset file can be recreated complete from the output
636
637 - sponde: now also allows the uasge of random forest
638
639 - sponde: added a plot showing the cut efficiency
640
641 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
642 errors (eg. effecting the collection area) because the errors of the
643 two histograms were swapped in the calculation, which makes a difference
644 in the case the histograms contains weighted events. Aditionally the
645 totalarea was incorrectly taken into account, which results in too small
646 errors, which makes a difference at low statistics were the errors
647 or the collection area dominate.
648
649
650
651 *** Version 0.10.3 (2006/10/23)
652
653 - database: Implemented ObservationMode flag in websites.
654
655 - database: For sequences there is now also the stoptime available on the
656 websites.
657
658 - database: Removed ManuallyChanged flag from sequence-info websites,
659 as it is not needed anymore with the new sequence building algorithm.
660
661 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
662 Class for calculation of confidence intervals (upper limits).
663 Use model 3 or 4 for upper limit calculation for MAGIC observations.
664 Please read the class instruction of TRolke for more information.
665
666 - general: The programs now return 0xfe if the requested resource file
667 doesn't exist.
668
669 - general: Errors comming from root itself are now not output to
670 stderr anymore but to our default (colored) log-stream.
671
672 - general: Changed the interface to TFormula such that now everything
673 is parsed by TFormula, which should allow to use phrases even
674 without paranthesis correctly parsed.
675
676 - callisto: replaced the AdHoc number of effective integration slices
677 in the digital filter by an average of the correct number, averaged
678 over all possible set of weights. This also gives correct numbers
679 for the lo-gains which were totally wrong before.
680
681 - callisto: drastically reduced memory consumption by not storing
682 all intermediate calibration results in memory anymore (we might
683 write them into a file in the future)
684
685 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
686 debug plot displayed as a standard plot) use the context menu
687 somewhere between the two upper plots, click on "DrawNicePlot"
688 and enjoy the result. (It is the same context menu which contains
689 the "DrawAll" option)
690 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
691
692
693
694 *** Version 0.10.2 (2006/10/15)
695
696 - general: changed the building of the sequence files such, that
697 the source-/project name in case of wobble-sources is not the
698 source/project of the first data run anymore but the new generalized
699 wobble source/project
700
701 - general: Added some functions to MAstro to calculate sun and
702 moon properties
703
704 - general: Added two new macros (starvisday.C and starvisyear.C)
705 which allow to plot the visibility of several stars in one day
706 or of one star along one year
707
708
709
710 *** Version 0.10.1 (2006/10/11)
711
712 - general: HTML logging output was distorted... fixed.
713
714 - general: Changed the writing of the sequencefiles such that only
715 as many pedestal files as giving at least 1000 pedestal events which
716 are nearby the first calibration run are used as pedestal runs
717
718 - sponde: In the calculation of the collection area(s) and the
719 distribution for MOnte Carlo and estimated energy the error
720 calculation was wrong because root didn't take the errors
721 properly into account... fixed.
722
723
724
725 *** Version 0.10 (2006/10/10)
726
727 - general: all executables now check consistency of the root version
728 installed with the root version used for compilation. The return
729 code in this case is 255.
730
731 - general: The algorithm to build seqeunces has been redesigned
732 completly. It is now more flexible in terms of a resource file
733 resources/sequences.rc which can be used to partly overwrite
734 the default algorithm and defined the important part of the
735 algorithm. It also takes correctly into account several ways
736 of taking wobble-data. Currently the new algorithm doesn't take
737 the number of pedestal events anymore into account (so a sequence
738 could have much less than 1000 pedestal events and data runs are
739 no-more used instead)
740
741 - general: a lot of small changes to make the code compatible with
742 root 5.12/00 and gcc 4.1
743
744 - general: Fixed some warnings thrown if more warnings are switched
745 on in the compiler
746
747 - general: Added a function to MMath which returns the Median of
748 the distribution abs(y[i]-median) but at 68:32 division instead
749 of 50:50, which is somehow the median counterpart of the rms.
750
751 - general: MAstroCatalog allows now to read calatog files (as bsc5)
752 even if they are compressed with gzip (recommended compression
753 is with "-1")
754
755 - showplot:
756 + batch mode creation of image files now works with root 5.12/00
757 + added support for writing bmp (though it never produces
758 bmp which can be read by programs like xv or gimp)
759 + added support for xml
760 + added new option to start the display with a different size, by
761 --display-width=nnn or --display-height=nnn
762 + added options to define the canvas size when the display is started
763 --canvas-width=nnn or --canvas-height=nnn
764 the option can also be used for batch-mode conversion
765 + added an option which automatically fits the display size to the
766 desktop-size: --auto-size
767
768 - merpp: didn't recognize files with the extension .raw.gz - fixed.
769
770 - merpp: allow the reports to have 1000ms due to a bug in the camera
771 program.
772
773 - callisto: New swapped pixels have been found and corrected. For
774 details see MRawRunHeader::FixAssignment()
775
776 - callisto: Callisto now raises an error if one of the input files could
777 not be opened.
778
779 - callisto: In some rare cases it could happen that in the signal
780 extraction of the digital filter the extractor returned nonsense
781 results due a wrong initializion of a variable (this happens in
782 cases in which the extracted signal is exactly zero or the
783 digital filter couldn't slide because of a too small extraction
784 window, which could happen in the lo-gain extraction)
785
786 - callisto: The lo-gains have been marked as valid in some cases
787 when they got not extracted at all (deltsumlo=deltatimelo=0) because
788 the allowed extraction range (fLoGainLast-fLoGainFirst) was
789 smaller than the number of slices (fLoGainWindowSize) needed
790 by the lo-gain extractor
791
792 - callisto: Updated absolute calibration constants (muon calibration)
793
794 - callisto: fixed a bug which caused the hi-gain saturation not
795 to be handled properly in the spline (the position of the
796 saturation was calculated incorrectly)
797
798 - callisto: fixed a bug which gave weird results if hi- _and_
799 lo-gain could not be extracted properly. In some cases hi-
800 and lo-gain have not been extracted at all and the random result
801 got calibrated. In other cases the hi-gain was saturating and the
802 lo-gain has not been extracted. For this a completly arbitraty
803 scale factor was applied to the result from extracting the
804 charge of the saturating hi-gain.
805
806 - callisto: improves handling of extracted signal if lo- and/or
807 hi-gain could not be extracted properly. If no appropriate
808 calibration of either the signal or the arrival time is possible
809 the pixel is now markes as unsuitable instead of estimated.
810
811 - callisto: Fixed a problem in the spline extraction which gave
812 weird results if the signal was extracted from the first (and
813 highest) slice (as a workaround extraction from the first
814 slice has been forbidden)
815
816 - callisto: Fixed a bug regarding the use of the QE which doesn't
817 effect the result because the default is used anyhow.
818 (The bug was there since 14/07/2005)
819
820 - callisto: Changed the default for fgLoGainStartShift to -2.4
821
822 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
823 factors to be always 10 for all pixels as soon as the first
824 calibration update has happend.
825
826 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
827 was off by more than one slice (which gives wrong values for
828 pixels which have saturated the hi-gain) This was a problem
829 mainly for timing studies, not so much for the automatic standard
830 analysis. Also the values for the Spline have been changed slightly:
831 + Digital Filter from 1.70 to 0.95
832 + Spline from 1.39 to 1.30
833 The numbers were sorted out by an extensive test in the
834 test-database.
835
836 - callisto: Removed the tab showing the average calibrated arrival
837 time. It never gave useful information.
838
839 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
840 lo-gain pulse for data pulses if hi- and lo-gain have saturated
841 and both were extracted because the hi-gain was above the
842 LoGainSwitch.
843
844 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
845 lo-gain pulse position (after application of LoGainOffset, which
846 means in the ideal case it is 0) for data pulses if hi- and lo-gain
847 have saturated and both were extracted because the hi-gain was above
848 the LoGainSwitch.
849
850 - callisto: After extensive tests a new threshold level for determination
851 of the pulse position has been found at 50phe. This is due to the
852 fact that for lower pulses the arrival time changes its average
853 behaviour dramatically. It tends to the average of the extraction
854 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
855
856 - callisto: Added two more plots to the calibration part. The average
857 extracted signal and the average extracted arrival time as
858 extracted by the signal extractor (This can help debugging problems
859 because it doesn't involve a fit)
860
861 - star: changed the fit for the effective on time such that initial
862 values are calculated automatically now instead of using build
863 in values. This makes the fit more indepedant of the underlaying
864 rates. With a test of ~350 sequences in the test database it could
865 be shown that the new fit gives the same result +/-1sek.
866 The highest deviation was +5s the lowest -10s. You can now control
867 the bahaviour with two resource values:
868 MHEffectiveOnTime.FistBin: 3
869 MHEffectiveOnTime.NumEvents: 12000
870 Use FirstBin=1 and NumEvents=120 to fit the effective on time
871 from the resulting gamma candidates
872
873 - star: The Center histogram in MHHillas is now by default displayed
874 with the colz draw-option
875
876 - ganymed: now produces valid error codes if failed
877
878 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
879 with the option "hadronness" instead of "area" or "both" if
880 you want to use both cuts. The hadronness cut includes a fixed
881 cut in hadronness (index 8) and a fixed cut in size (index 9).
882
883 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
884 the M3Long of the anti source to be not properly evaluated
885 (actually is was evaluated as a unique random number) in case
886 of optimization with anti-theta cut switched on. This might have
887 lead to improper, but not necessarily wrong, optimization results.
888
889 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
890 how to use random forest
891
892 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
893 ganymed_onoff.rc. Seems to be unintentional that they were different.
894
895 - sponde: Since the introduction of the possibility to define a
896 normalization energy instead of using the integral the default
897 was not using the integral anymore but a normalization energy of
898 1GeV. It is now the integral again.
899
900 - sponde: Fixed a problem in the weighting which did not allow
901 a MC slope of -1.
902
903
904
905 *** Version 0.9.6 (2006/05/24)
906
907 - general: changed the binning of the azimuthal profile of the camera
908 such that it is aligned with the 60deg boundaries.
909
910 - merpp: better handling of problems with the TH, TD part of the
911 CC-REPORT for files older than 200507190 and 200412210
912 respectively
913
914 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
915
916 - merpp: implementd latest changes in starguider reports (sinc 9th May)
917
918 - callisto: if an arrival time is extracted outside the fadc range is
919 was set to the boundary before. Now a random number is assigned
920 instead to avoid unfortunate coincidences of arrival times just
921 by this arbitrary value.
922
923 - callisto: added a new option to callisto.rc which allows
924 to set the maximum arrival time difference allowed for the
925 badpixel algorithm to determin whether a pixels belongs to a shower:
926 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
927
928 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
929 to 0.9 as suggested by Stefan due to a recent study on the fraction
930 of pixels surviving the image cleaning
931
932 - callisto: switched off error in case of "pulse is too much to the left"
933
934 - callisto: The extraction window is not adapted anymore. This means that
935 the pulse is extracted from the full range. The draw-back is that the
936 background (pedestal) will become slightly higher. Switching on/off
937 the PulsePosCheck in the callisto.rc only effects filling the
938 histograms.
939 WARNING: If the pulse is too much to the left data is calibrated!
940 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
941 in the database to make sure that your data is valid!
942
943 - star: Show also the number of stars correlated correctly by the
944 starguider
945
946 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
947 than one off-source region in wobble-mode. To use it add the following to
948 your ganymed_wobble.rc:
949 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
950 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
951 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
952 + Cut1.ThetaCut: None
953 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
954
955 - ganymed: in the case the latest report is older than a default (currently
956 one minute) and the current report will be skip the starguider
957 correction and calibration will be reset. The maximum age can be
958 setup from ganymed.rc by (minutes):
959 MPointingDevCalc.MaxAge: 1.5
960
961 - ganymed: A first implementation showing all size-bins for the theta-sq
962 resp. alpha-plots in a single tab automatically
963
964
965
966 *** Version 0.9.5.1 (2006/05/05)
967
968 - general: Added a new option "zdiff" to the Makefile which runs
969 "cvs diff" as "make diff" would do, but with compression
970
971 - general: accelerated MTFillMatrix (used for eample in all training
972 and optimization macros) by skipping some obsolete calles in the
973 eventloop the first and second loop could be accelerated by ~20%
974
975 - general: Added a missing feature in the MFilterList class which
976 prevented MFEnergySlope from working correctly in trainenergy.C
977
978 - general: Accelerated the random forest training and usage a bit
979
980 - merpp: Adapted to new raw data file format version 6
981
982 - merpp: fixed a problem with reading the starguider reports
983 after 6.3.2006
984
985 - callisto: At some times six pixels had to be exchanged manually in the
986 data. If the pixels to be swaped are both not found, an error was raised
987 and calibration was stopped. Now it is assumed they are intentially not
988 mapped and the Error has been changed to a Warning.
989
990 - star: Added new image cleaning based on the arrival time of the shower.
991 The new cleaning can be accessed using the parameter "Time" instead of
992 the the old one (like "Absolute) in the star.rc-file.
993 Recommended parameters:
994 + MImgCleanStd.CleanLevel1: 8.2
995 + MImgCleanStd.CleanLevel2: 5
996 + MImgCleanStd.CleanRings: 2
997 + MImgCleanStd.KeepSinglePixels: No
998
999 - star: Simplified the calculation of the effective on time. By letting
1000 the fit start in the third bin the result should become more stable.
1001 The fit quality is now ignored for the theta-plot which is not used
1002 in the analysis later. Still better pre-cut which, for example,
1003 remove events triggered by car-light (rate changing on a short
1004 time-scale) are missing.
1005
1006 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1007 for optimization (kWeakSource) which is suggested by the Berlin
1008 people for weak sources.
1009
1010 - macros: plotdb.C:
1011 + if no dataset and no time-interval is given only sequences with
1012 an effective on-time above five minutes are plotted anymore
1013 + added a new tab "RelTime" displaying the relative on-time
1014 (effective on-time divided by the observation time)
1015
1016 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1017 the optimization became a lot faster
1018
1019 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1020 To display them just delete the pads displayed on top.
1021
1022 - ganymed: fixed a bug which could cause strange behaviour in wobble
1023 mode if no starguider information was available due to an incorrect
1024 initialization of the starguider calibration
1025
1026 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1027 be changed from within the plot. It can also be setup from the
1028 resource file using:
1029 + MHDisp.fScaleMin: 0.325
1030 + MHDisp.fScaleMax: 0.475
1031
1032 - ganymed, showplot: Fixed a problem with the fit to the off-data
1033 (HistOff) which could cause a time lag or an inifinite loop.
1034 The bug did not effect the results at all.
1035
1036 - sponde: Added a new tab showing the effective collection area after
1037 trigger (including the software trigger)
1038
1039 - sponde: MMcSpectrumWeight has a new option which allows to define
1040 the scaling factor not by the integral of the events but at
1041 a defined energy:
1042 e.g. MMcSpectrumWeight.NormEnergy: 200
1043
1044 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1045 eventloops the loop could be accelerated by ~20%
1046
1047
1048
1049 *** Version 0.9.5 (2006/03/13)
1050
1051 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1052 and added the standard Disp-parametrization
1053
1054 - macros: added a new macro datacenter/macros/plotstat.C allowing
1055 to plot statistics about the data processing
1056
1057 - macros: added a new macro to plot the muon correction coefficients
1058 versus period (macros/plot/mucal.C)
1059
1060 - showplot: path inflation for ganymed files was broken
1061
1062 - callisto: Fixed an important bug. When the number of saturating pixels
1063 were calculated the bad pixel information already available from the
1064 calibration was ignored. This yields wrong values in case pixels
1065 are broken and saturate all the time or randomly.
1066
1067 - callisto: Updated Muon calibration constants. Spline data now also uses
1068 different values for different periods
1069
1070 - star: The time-evolution shown in the effective on-time plot now displays
1071 the axis range (if there are no holes it should be similar to the
1072 effective on-time)
1073
1074 - star: Added two new image parameters:
1075 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1076 the three pixels next to the center of gravity and the size
1077 + MNewImagePar.fConcCore: The ratio of the signals of all
1078 pixels inside or touching the ellipse and the size
1079
1080 - ganymed: now stops in requested source isn't found in catalog file
1081
1082 - ganymed: Many improvements to the phi-plot in wobble mode:
1083 + with a template the ideal background is displayed
1084 + a possible camera inhomogeneity is taken into account
1085 + the anti theta cut is better supported
1086 + the phi cut is automatically calculated from the theta cut
1087 See the examples in ganymed_wobble.rc for more details.
1088
1089 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1090 times the bin-width instead of the absolute energy
1091
1092 - ganymed: New cuts for on/off and wobble mode
1093
1094 - ganymed: The smearing of the False Source plot has been increased
1095 to 0.06
1096
1097 - ganymed: The starguider calibration can now be changed from the
1098 resource file.
1099 See the examples in ganymed*.rc for more details.
1100
1101 - ganymed: added a new option for on-/off-observations
1102 MJCut.RandomSourcePosition
1103 If switched on the distribution of observation time of the source
1104 position in the camera is calculated from the on-data and randomly
1105 applied with this distrbution to the off-data.
1106
1107 - ganymed: by skipping some obsolete calles in the eventloop the
1108 first and second loop could be accelerated by ~20%
1109
1110 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1111 position in the off-data randomly according to its distribution in the
1112 on-data.
1113
1114
1115
1116 *** Version 0.9.4.3 (2006/02/13)
1117
1118 - general: Fixed a bug in most of the programs which prevented the
1119 compile date in the startup message to be displayed
1120
1121 - general: Simplified program calls. The following abbreviations
1122 are now possible:
1123 showlog callisto 55599
1124 showplot signal 55599
1125 star 55599
1126 callisto 55999
1127 ganymed 2
1128 In this cases the corrsponding root-, log-, sequence- or dataset-
1129 filename is automatically compiled using the default datacenter
1130 paths ("/magic/*")
1131
1132 - general: Fixed a long outstanding bug which made axis tick marks
1133 disappear if MDataFormula was used (eg. abs(x))
1134
1135 - general: Updated MMath with new functions to calculate the results of
1136 a exponential, logarithmic and powerlaw fits analytically.
1137
1138 - general: Updated some macros with comments:
1139 + macros/optim/optimdisp.C
1140 + macros/optim/optimenergy.C
1141 + macros/optim/optimwobble.C:
1142
1143 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1144 files) now allows adding a pre-cut like in the optimization. E.g. this
1145 is useful to perform g/h-separation cuts before training the random
1146 forest.
1147
1148 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1149 correctly assigned in the raw data assignement table. A fix to correct
1150 the assignment tabel have been implemented.
1151
1152 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1153 by 90, 180 and 270 deg.
1154
1155 - general: the macro plotdb.C now allows to highlight sequences belonging
1156 to a datset. For more details see the descritions in the macro.
1157
1158 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1159 of the display, it gave wrong results espacially for big sizes.
1160 Now the embedded canvas should always have a ratio width/height=3/2.
1161 The "Size" options have been updated with values fitting the 3/2
1162 size ratio.
1163
1164 - RanForest:
1165 + Updated the random forest classes to support also the
1166 regression method implemented by Thomas H.
1167 + added new tutorial macro how to train the random forest
1168 for energy estimation (macros/optim/rfenergyest.C)
1169 + new classes to train the random forest (still in development)
1170 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1171 + new tutorial macros for random forest training in macros/train
1172 trainenergy.C, traindisp.C, trainseparation.C
1173
1174 - mars: now allows to setup a cut in the resource file mars.rc to choose
1175 the events to be displayed, eg:
1176 Cut.Condition: {0} && {1}
1177 Cut.0: MHillas.fSize>100
1178 Cut.1: MHillas.fSize<900
1179
1180 - merpp: Made aware of the new .rep format 200510250. This includes
1181 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1182 the discriminator thresholds (MCameraTD) and the disciminator
1183 delays (MCameraTD). All of them come with the CC report and are therefor
1184 written to the CC tree.
1185
1186 - callisto: fixed a bug in the calculation of the arrival times in
1187 the Digital Filter. They were all shifted by the same amount
1188 fHiGainFirst. This caused an offset in the order of the position of
1189 the left border of the extraction window in the times calculated
1190 from high-gain and from low-gain. The bug effected only the absolute
1191 arrival times. The bug was there since 30.1.2005.
1192
1193 - callisto: Changed the ExtractionWindow for the pulse position check
1194 such that the camera inhomogeneity becomes as less as possible and
1195 comparable to the pulso position check switched off. More details
1196 on the study will be given at our result web-page.
1197
1198 - ganymed: ganymed.rc, ganymed_onoff.rc:
1199 changed to new cuts trained with 1ES1218 and Crab-data
1200 for maximum sigma*log10(excess)
1201
1202 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1203 a new option was implemented to estimate Disp (CalcDisp)
1204
1205 - ganymed: Implemented two new options which allow
1206 to overwrite the default path to search for the sequence files
1207 --ins=/magic/sequences
1208 and where to search for the image data
1209 --ind=/magic/data/star
1210
1211 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1212 dx/dy from the resource file by
1213 MSrcPosCorrect.Dx
1214 MSrcPosCorrect.Dy
1215
1216 - ganymed: fixed reading the source catalog. Only as many chars
1217 as the requested source name had were compared (If a source
1218 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1219 were requested it could happen that the coordinates of
1220 "1ES1218" were read) The source coordinates are now printed
1221 in addition to its name to the logging output.
1222
1223 - ganymed: changed the background fit in the case of a ThetaSq function
1224 from a polynomial to a exponential, this should give a big improvement
1225 for on-only analysis'
1226
1227 - ganymed/sponde: Calculation of the error of single size-/energy-
1228 bins now uses Li/Ma (5) instead of LiMa (17)
1229
1230 - sponde: Added a plot E^2*dN/dE
1231
1232 - sponde: The energy estimator plot should now show values like
1233 they are commonly used.
1234
1235 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1236 (a powerlaw with cutoff didn't work before)
1237
1238
1239
1240 *** Version 0.9.4.2 (2005/10/01)
1241
1242 - general: added new tutorial macro macros/tutorials/threshold.C:
1243 how to calculate the threshold
1244
1245 - general: added a new game. Start it from the interpreter with
1246 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1247 and MagicReversi)
1248
1249 - general: neighbor pixels in MGeoms are now sorted clockwise
1250
1251 - merpp: made aware of new format 20050829-0
1252
1253 - callisto: New scale factors from muon analysis, stored in new
1254 resource file resources/calibration.rc
1255
1256 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1257 the eventloop if something went wrong. This is necessary for the
1258 automatic processing
1259
1260 - callisto: Implemented a new treatment for the time information
1261 developed by S.Ruegamer, this should give much better response than
1262 the old very primitive algorithm. This is especially important
1263 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1264 treatment was buggy! As neighbor pixels to interpolate the
1265 arrival times always the pixels 0 to 5 were taken)
1266
1267 - callisto: In addition to the new treatment of arrival times the
1268 decision of the treatment whether a pixel contains shower
1269 information or not is used to improve the signal interpolation
1270 further. Previously interpolated pixels showed a non-zero signal
1271 do the peak searching signal extractors. Having a signal pixel
1272 beside raised the signal above the cleaning level. Thus the
1273 pixel survived cleaning to often but with a too low mean signal.
1274 By replacing empty pixels with a gaus (mean and rms from the
1275 corresponding Area entries in MPedPhotCam) this effect can
1276 be supressed.
1277
1278 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1279 got lost when the events were stored by the calibration... fixed.
1280 (This was no problem for normal image cleaning because the pixel
1281 content was artificially set to 0 not surviving standard cleaning
1282 algorithm)
1283
1284 - callisto: Fixed a bug which caused the random and peak-search pedestal
1285 extracted with an extractor to be exchanged for the first (roughly)
1286 500 events (*Extractor and *ExtractorRndm).
1287 (They were simply exchanged in callisto.cc) This bug might have been
1288 introduced in Mars 0.9.4 when the order of calculation of the two
1289 types of pedestal in callisto got exchanged. The bug only effects
1290 the first seconds of data of each sequence.
1291
1292 - star: Taking the arrival time of Muons into account the calculation
1293 of the parameters could be made independant of the noise
1294 (pedestal rms). The dependance was due to the bias of the peak search
1295 extractor. Now only a ZA dependamcy is left which is not yet fully
1296 understood.
1297
1298 - ganymed: The sequences were still not sorted correctly in any case,
1299 because they were sorted by the full qualified path name. Now they
1300 are sorted by their sequence number.
1301
1302 - ganymed: new values for the spark-event-cut
1303
1304 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1305
1306
1307
1308 *** Version 0.9.4.1 (2005/08/18)
1309
1310 - callisto: fixed some problems with the calibration in case of
1311 inteleaved events. Therefor the final and some intermediate
1312 fits are skipped which would take place on partly filled #
1313 histograms and gave wrong results or failed completely.
1314
1315 - callisto: If the intermediate finalization of the histograms
1316 calculating the mean charge of the calibration signal fails
1317 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1318
1319 - ganymed: Fixed some bugs which caused problems in On-only mode.
1320 Still the false source plot doesn't give reasonable results.
1321
1322
1323
1324 *** Version 0.9.4 (2005/08/05)
1325
1326 - general: Fixed the ZA binning. It did not correctly fit the
1327 MC binning
1328
1329 - general: Added a class to correct for the missfocussing in
1330 April (MSrcPosCorrect)
1331
1332 - general: Random Forest energy estimator should now work properly
1333
1334 - general: MHCamera now displays the profiles in deg instead of mm
1335
1336 - general: MH::SetPalette offers a lot of new palettes
1337
1338 - general: MHillas - the case of CorrXY==0 is now handled properly
1339
1340 - general: implemented the possibility to change the line and
1341 marker style of a sky-grid drawn by MAstroCatalog
1342
1343 - general: Runs in sequences and datasets are now automatically
1344 ordered (it is assumed that the order of their filenames correctly
1345 represents the order of observations) to ensure correct reading
1346 of the subsystem data
1347
1348 - general: Runs cannot be added to a sequence twice anymore. Also
1349 Sequences cannot be added twice anymore to a dataset.
1350
1351 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1352 It gave wrong results by 1./2pi
1353
1354 - showplot: got a new option to start a root interpreter, too
1355
1356 - mars: now displays a rough estimate of Disp and the third moment
1357
1358 - mars: now displays the event time MTime if available
1359
1360 - mars: show muon parameters graphically
1361
1362 - mars: now the file to open can be given as commandline
1363 argument
1364
1365 - merpp: Added support for new arehucas version >= 200507190
1366 implementing values for three temperature sensors in the
1367 counting house (MCameraAUX) and the name of the HV settings file
1368 (MCameraHV).
1369
1370 - merrp: Also fixed some problems with wrong versions numbers stated
1371 by arehucas and implemented some fixed for old versions (<200407070)
1372
1373 - callisto: MCalibrationHiLoCam can now be printed from its context
1374 menu, eg in the TBrowser
1375
1376 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1377 - 1.39 (MExtractTimeAndChargeSpline)
1378 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1379 This is important mainly for timing studies.
1380
1381 - callisto: Changed limits in MHCalibrationChargeCalc from
1382 - -100.125 to -98 (fgChargeHiGainFirst)
1383 - 1899.875 to 1902. (fgChargeHiGainLast)
1384 - -100.25 to -99 (fgChargeLoGainFirst)
1385 - 899.75 to 901. (fgChargeLoGainLast)
1386 Introduced new limits:
1387 - fgNumLoGainBlackoutLimit: 0.05
1388 - fgLoGainBlackoutLimit: 3.5
1389 - fgLoGainPickupLimit: 3.5
1390
1391 - callisto: The handling of automatic weights for the digital filter
1392 has been improved. There are now new calibration weights special
1393 for Monte Carlo calibrations.
1394
1395 - callisto: Updated Muon scale with latest results (1% difference
1396 for most data, 5% for Mar/Apr'05)
1397
1398 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1399 was saturated and the blackout-events in the low-gain exceed the
1400 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1401 This excludes those pixels which have a saturating high-gain
1402 channel, but the low-gain switch does not switch often enough
1403 to make the distribution reliable.
1404
1405 - callisto: fix a bug counting the number of saturated events. Up to now,
1406 the number of saturated slices was counted (which is one for a not too
1407 high number), but for some (pathological) pixels, many more slices
1408 saturated and produced wrong limits.
1409
1410 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1411 + MCalibrationRelTimeCam.CheckFitResults: Yes
1412 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1413 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1414 + MCalibrationRelTimeCam.CheckOscillations: Yes
1415
1416 - callisto: introduce max. number of events for intercalibration,
1417 the rest gets skipped. Default: 4096
1418 The calibration causes too many un-reliable pixels if more
1419 than about 5000 events are treated (@500 Hz) because of the
1420 mode hopping of the VCSels. However, in the past, some
1421 calibration runs have been taken (erroneously) with more
1422 than 5000 events, especially the intensity scans where
1423 a good precision is needed.
1424
1425 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1426 photo-electrons for the spline extractor by 1-2% (correctly).
1427
1428 - callisto: The intercalibration is now done using a full f-factor
1429 method instead of a simple update. This makes things slower but
1430 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1431 changes.
1432
1433 - callisto: MPedestalY3 now uses the same extraction range as the data
1434 as calculated by MPedestalY2
1435
1436 - callisto: A check of the fraction of allowed unsuitable (10%) and
1437 unreliable (30%) pixels has been addded when the conversion is
1438 calculated from interleaved events
1439
1440 - star: fixed a bug which caused MEffectiveOnTime containers not to
1441 be written. In the worst case they were skipped almost all, in the
1442 best case they were all ok. It depends on how often the new value
1443 was assigned just with an event which was skipped later by another
1444 task
1445
1446 - star: new histograms MHPointing and MHRate
1447
1448 - star: New tab (Currents) displaying the time evolution of the mean
1449 DC currents
1450
1451 - star: New tab (MeanRms) displaying the time volution of the mean
1452 Pedestal Rms
1453
1454 - star: Output now contains MReportStarguider
1455
1456 - star: Improved muon analysis. Due to the absense of a constant
1457 for the gaus fit for arc width and the fact that the arcwidth
1458 plot was a histogram instead of a profile the resulting psf
1459 became pedestal rms dependant
1460
1461 - ganymed: added new plot (MHPhi) for wobble mode as described in
1462 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1463
1464 - ganymed: corrects now (correctly?) for the misspointing in
1465 May/April 05
1466
1467 - ganymed: Two new default templates for ganymed.rc are avilable:
1468 ganymed_onoff.rc and ganymed_wobble.rc
1469
1470 - ganymed: The first version of MFMagicCuts has been released
1471
1472 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1473
1474 - ganymed, sponde: There are two new options to determin the number
1475 of bins for the signal region (NumBinsSignal) and the number of
1476 total bins (NumBinsTotal) in the MHThetaSq histogram
1477
1478 - ganymed: optimized palettes for MHDisp
1479
1480 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1481 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1482 sqrt(2) to large
1483
1484 - ganymed: The false source plot (MHDisp) is now based on Disp
1485 and a background model determined in the first loop is
1486 subtracted
1487
1488 - ganymed: MFMagicCuts are now available in the cvs. The correct
1489 solution for the disp ambiguity problem is now calculated using
1490 the third moment. The third moment cut therefor is skipped.
1491
1492 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1493 already determined by the third moment along the major axis and
1494 so its actual sign is aligned along the major axis of the shower.
1495
1496 - ganymed: If starguider data is available it is taken into account
1497 when calculating the source position. This is especially important
1498 for wobble data at high zenith angles and culmination data.
1499
1500 - ganymed: If available the starguider data is taken into account as
1501 good as it is possible without a starguider calibration. To switch
1502 it off add
1503 MPointingDevCalc.MaxAbsDev: -1
1504 to your ganymed.rc
1505
1506 - sponde: the zenith angle distribution is now weighted instead of
1507 choosen by default. This gurantees higher statistics in the highest
1508 and lowest energy bins. To switch this behaviour off use...
1509
1510 - sponde: now automatically displays the energy threshold
1511
1512
1513
1514 *** Version 0.9.3 (2005/06/03)
1515
1516 - general: MMcEvt now derived from MMcEvtBasic which should
1517 have no influence on compatibility with older camera files
1518
1519 - general: Implemented a new option to MReadReports which allows
1520 to force reading of the first event of some trees (eg. Drive-tree)
1521 before any other tree.
1522
1523 - general: Made a fix to MPointingPosCalc which assumes that the
1524 run-type is real-data if Process is called before ReInit, such
1525 that also the very first Drive-events in a run are treated
1526 correctly.
1527
1528 - shoplot now displays the filename in the title bar of the window
1529
1530 - merpp: new options: --auto-time-start --auto-time-stop which
1531 allow to cut updating with slow-control at the start- or
1532 (previousle --auto-time only allowed: and) stop-time of
1533 the run stored in the runheader.
1534
1535 - callisto: changed default of fgFallTimeHiGain in
1536 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1537 already set as default in callisto_Dec04Jan05.rc
1538
1539 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1540 now changes the filename for new weights automatically for
1541 cosmics, MC and for different calibration colors.
1542
1543 - callisto: a problem with the order of some code cause the
1544 name of the weights file in MPedestalY2 to be ignored.
1545 Wrongly the calibration_UV weights were used instead
1546 of the cosmics weights set in callisto.rc.
1547
1548 - callisto: should allow ct1 pulser data when the color is
1549 explicitly set also for pretty new runs
1550
1551 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1552 to introduce an additional scale factor (should be around 1)
1553 to adapt for slight deviations in different extractors from
1554 the MC calibration. For MC calibrations the scale factor
1555 is fixed to 1
1556
1557 - callisto: MFCosmics should handle very high signals a bit
1558 more accurate now
1559
1560 - callisto: when calculating the mean pedestal rms for different
1561 pixel sizes or sectors also kUnsuitableEvt is now taken into
1562 account - not only kUnsuitableRun
1563
1564 - callisto: '-raw' option is now the default
1565
1566 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1567 This has the advantage that mean values in the calibration (eg
1568 arrival times) are calculated more accuratly.
1569
1570 - callisto: In the resource file callisto_Dec04Jan05.rc
1571 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1572
1573 - callisto: new Hi-/Lo-Gain intercalibration constants
1574 hilocalib_sp1.root and hilocalib_sp1_mc.root
1575
1576 - callisto: changed default for MJPedestalY2.MaxEvents
1577 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1578
1579 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1580 has changed from 9.0 to 6.0. This is necessary to exclude two very
1581 ringing pixels in September which - when kept - destroy the image
1582 cleaning around them (Markus G.)
1583
1584 - callisto: (!) The Muon analysis of all data taken so far has
1585 suggested that different extractors give slightly different
1586 absolute results after calibration, due to there different
1587 handling of the calibration- and cosmics pulse shape. Although
1588 the over all calibration seems to be a bit to pesimistic (or
1589 the MC seems to be a little bit - 3-5% - too much attenuated).
1590 There for correction factors have been introduced which correct
1591 the calibration constants by
1592 0.956937799 for Digital Filter (callisto.rc)
1593 and
1594 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1595 calibration. The main advantage is, that both data types can
1596 be easily analysed together and compared to the same MC sample.
1597 The factors are choosen such, that the reference is now a
1598 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1599
1600 - star: fixed a bug which caused the first bin of the histograms
1601 vs time to disapear in PostProcess. This gave wrong results
1602 on the screen. The output and all following programs not
1603 directly accessing the histograms haven't been affected
1604
1605 - star, ganymed: Made sure that always the first Drive-tree event
1606 is read and Processed before the first data event was read.
1607
1608 - ganymed: implemented the possibility to replace the standard
1609 false source plot with a different one. For example: If
1610 you want to use a Disp based FS plot use the resource:
1611 NameHistFS: MHDisp
1612 For details about the requirements of these plots look
1613 at the corresponding classes
1614
1615 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1616 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1617 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1618 case MAlphaFitter is setup correctly. For On-Only optimization
1619 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1620 RunOn() instead of Run(). For energy estimation MJOptimize
1621 has been replaced by MJOptimizeEnergy
1622
1623 - sponde: The input MC spectrum can now be weighted to fake a
1624 different spectrum. This is done via MMcSpectrumWeight. For
1625 more details see the class description and sponde.rc
1626
1627 - sponde: The paremeter comparsion plots are not scaled by
1628 their entries anymore. Instead the MC plot is scaled by using
1629 the result spectrum of the analysis. If the input MC spectrum
1630 and the result spectrum has different slopes the absolut
1631 normalization is normally wrong.
1632
1633
1634
1635 *** Version 0.9.2 (2005/05/20)
1636
1637 - general: Changed the default paths for calibrated data and image
1638 files. (The implemented access to these files doesn't yet exist)
1639
1640 - general: support for MRunIter has been removed from the job classes
1641 (use the setter functions of MSeqeunce instead)
1642
1643 - general: ProcessFile has been renamed to Process in all job classes,
1644 because ProcessFile is missleading
1645
1646 - general: The storage of the palette in MHCamera is now possible
1647
1648 - general: new bits describing unsuitable and unreliable pixels have
1649 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1650 kDeadPedestalRms, kFluctuatingArrivalTimes
1651
1652 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1653 versions newer than V200404070
1654
1655 - general: support for cc file versions newer than V200504130. Added
1656 support for active loads (MCameraActiveLoad) and central pixel
1657 (MCameraCentralPixel)
1658
1659 - general: added new histograms for image parameters versus size
1660 (MHVsSize)
1661
1662 - general: The eventloop now automatically calls PrintStatistics
1663
1664 - Status Display: Improved support for printing:
1665 + A default can now be set in .rootrc (for more details see
1666 MStatusDisplay::PrintPS)
1667 + A print dialog is opened so that printer and command line
1668 can be canged
1669
1670 - showlog: improved such that it handles different verbosity levels
1671 more accurate now. This mean you can suppress output when
1672 using showlog.
1673
1674 - showplot: improved
1675 + The new graphics formats have been implemented
1676 (pdf, svg, png, jpg and xpm)
1677 + Implemented an interface for printing. Because you can change
1678 the printing command from the command line you can use all
1679 the nice postscript tool. To print a booklet for example call:
1680 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1681 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1682 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1683
1684 - callisto: fixed a bug in the recognition of the calibration bit
1685 pattern. Concerns only intensity calibration. (The strength of the
1686 intensity has been updated in some cases)
1687
1688 - callisto: add a filter against PIN Diode events when running over
1689 calibration runs since some of the recent calibration runs have
1690 been taken with Pin Diode.
1691
1692 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1693 39943, 44833 in the calibration (MCalibColorSet)
1694
1695 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1696 been set to 1e-18 in callisto_Dec04_Jan05.rc
1697
1698 - callisto: in callisto_Dec04Jan05.rc: set value for
1699 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1700 statistics for the calculation of the mean pulse time
1701 of the cosmisc
1702
1703 - callisto: the charge limit in the calibration has been raised
1704 from 2.5 to 4.5
1705
1706 - callisto: new setup read from callisto.rc
1707 + MCalibCalcFromPast.fNumEventsDump
1708 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1709 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1710
1711 - callisto: MExtractTimeAndChargeSpline extractor:
1712 + The integration ranges were shifted by 0.2 FADC slices to the right.
1713 + unreliable handling of floating point values caused different
1714 results on different platform or with different compiler options:
1715 The new algorithm is numerically exact and more accurate because
1716 it doesn't calculate the integration position by multiple times
1717 adding the step-size (which results in numerical uncertanties
1718 exspecially if multiplied with large numbers)
1719 + A lot of fixes have been introduced which effects integrating the
1720 spline at the edges of the valid range. In this case any memory
1721 was randomly accessed. This behaviour can be tested replacing
1722 all MArrayF by TArrayF which perform a range check (but of course
1723 they are a lot slower)
1724 ! No result obtained with the Spline before can be trusted! Due to
1725 random memory access it might by completely random!
1726
1727 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1728 + extraction range in the high gain to 4.
1729 + weights file to cosmics_weights46.dat
1730
1731 - callisto:
1732 + introduce the check for fluctuating arrival times.
1733 + set charge limit to from 2.5 to 4.5
1734 + introduce asymmetric exclusion due to "deviating number of phes":
1735 Default: -9.0 +4.5
1736 + make deviating number of phes unsuitable (see David's findings).
1737
1738 - callisto: fixed the display of unsuitable pixels. The old change
1739 to a real profile in MHCamera broke it.
1740
1741 - callisto: The cosmics filter is used in MJCalibration now
1742 independant of the pulser color (formaly it was used only for
1743 CT1-pulser data). The threshold of number of max empty pixels
1744 has been raised from 2% to 5% in MJCalibration. The maximum
1745 fraction of rejected event is 50% otherwise the calibration has
1746 failed. The filter now ignores unsuitable pixels.
1747 Setup the filter from callisto.rc using "ContCosmics"
1748 (see MFCosmics::ReadEnv)
1749
1750 - callisto: changed default for fgOffsetFromLogain back
1751 from -2.8 to -1.8 in digital filter.
1752
1753 - callisto: for the common extractors
1754 + MExtractFixedWindow
1755 * MExtractTimeAndChargeSlidingWindow
1756 * MExtractTimeAndChargeSpline
1757 * MExtractTimeAndChargeDigitalFilter
1758 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1759 and fResolutionPerPheLoGain
1760
1761 - callisto: Updated the hi-/lo-gain intercalibration constants
1762 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1763 hilocalib_df6.root
1764
1765 - callisto: The default lo-gain extraction window for the
1766 MExtractTimeAndChargeSlidingWindow extractor has been increased
1767 from 6 to 8 to take the stretch of the pusle into account
1768
1769 - callisto (!!!): fixed an important bug in the setting of the
1770 incoming pedestal pointer to the signal extractor extracting
1771 pedestals. This bug caused the pedestals not to be subtracted
1772 correctly in the calibration afterwards. The effect was about 10%
1773 too high conversion factors for the digital filter and the spline
1774 and more than 40% for the sliding window.
1775 The bug existed since end of February! (Markus G.)
1776
1777 - star: added muon support to star. A new tab "MHMuonPar" is
1778 displayed. The lower right plot is an estimate of the point spread
1779 function. A reference value is displayed. To get the real PSF
1780 you must compare with MC. The setup for the muon analysis
1781 is done in star.rc. More informations can be found in
1782 MHSingleMuon and MHCalibParCalc
1783
1784 - star: The weather data is now displayed in star
1785
1786 - star: MEventRateCalc handles the calculation of the event rate more
1787 accurate now in case of the start of a new run inside a sequence
1788
1789 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1790 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1791 changed only minimally
1792
1793 - ganymed: (MJCut and MJOptimize) now displayes the number of
1794 excess events versus size. The energy estimation is done in
1795 MJSpectrum (sponde)
1796
1797 - ganymed: got support for using other variables than Alpha, eg. Theta.
1798 Therefor you need a class deriving from MHAlpha which supports
1799 this variable (one is already existing: MHTheta, which is now the
1800 default in ganymed). It is setup through ganymed.rc
1801
1802 - added a full featured spectrum program (sponde) which reads
1803 ganymed output and monte carlos and compiles a spectrum
1804
1805
1806
1807 *** Version 0.9.1 (2005/04/14)
1808
1809 - Fix bug on the arrival time reconstruction when using Digital
1810 Filter (in some marginal cases (10%) times were reconstructed shifted
1811 by 0.2 slices)
1812
1813 - all executables now return 2 where in previous versions -1 has
1814 been returned (gave problems with shell-scripts)
1815
1816 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1817 also done with a intercalibration input file
1818
1819 - a bug in the time fine adjustment of the digital filter has been fixed
1820
1821 - a lot of small fixes to calling TPad::Divide with a margin==0
1822
1823 - MStatusDisplay now shows the memory usage
1824
1825 - added a memory leak statistic after the eventloop
1826
1827 - MHadronness replaced by MParameterD
1828
1829 - MEnergyEst replaced by MParameterD
1830
1831 - wobble mode can now be switched on from the data-set
1832
1833 - switched on bad pixel detection for a pedestal level
1834 which is more than 5 times the variance
1835
1836 - Fixed default paths to be correct for the new data center
1837
1838 - Fixed handling of drive data. The pointing position in now
1839 copied to MPointingPos inside star for real and MC events
1840
1841 - made sure, that the sequences in a dataset are sorted by
1842 their number to ensure the correct synchronization
1843
1844 - added all resource files necessary to handle spline extraction
1845 of signal for the late 2004 and the early 2005 data
1846
1847 - update the reference lines for the december data
1848
1849 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1850 This is important for the Dec. and Jan. data where the calibration
1851 pulse position changes much.
1852
1853 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1854 filter. This corrects only an defective extraction of the MC at
1855 low-gain signals lower than 90 phes.
1856
1857 - fixed some slowdown in calibrating data with interleaved events from
1858 Jan and Dec. As a workaround made the pretty palette the default.
1859 The inverse Deep Blue Sea has a bug which slows down long calibration
1860 runs a lot.
1861
1862 - implemented new values from new starguider report as defined
1863 in TDAS00-07 V7.1 (eg SkyBrighness)
1864
1865 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1866 in starguider report (If you merpp the same reports with this version
1867 you'll get the correct units (arcmin) but a different result
1868 than with old versions (wrong units))
1869
1870 - Now the status display can also write PNG, JPEG and XPM (other file
1871 formats are still unsupported by root)
1872
1873 - added a lot of scripts and macros in directory datacenter used
1874 for automatic processing
1875
1876
1877
1878 *** Version 0.9 (2005/03/23)
1879
1880 - Calibration is now done autmatically into photo-electrons like
1881 decided by the Collaboration Board
1882
1883 - Reference lines in the display can be read from resource file
1884
1885 - Interlaced calibration events can be handled by callisto
1886
1887 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1888 and applied in callisto.
1889
1890 - class MJCalibTest can be called by callisto
1891
1892 - callisto can now run with three data types: rawdata, rootdata, MC
1893
1894 - added two classes mreport/MReportStarguider.cc and
1895 mreport/MReportStarguider.h for implementing starguider-data
1896
1897 - the output of merpp-update now contains starguider information:
1898 MReportStarguider and MTimeStarguider
1899
1900 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1901 values were lower than they should. This was more visible for high
1902 energy (Size) events.
1903
1904 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1905
1906 - added a new loop to callisto to support the correct extraction of
1907 the pedestal and pedestal rms through the signal extractor
1908
1909 - added class to perform fourier tranformation of a hexagonal structure
1910 (MHexagonalFT)
1911
1912 - added class to perform fourier tranformation of a hexagonal structure
1913 in a tasklist (MHexagonalFTCalc) example: hft.C
1914
1915 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1916 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1917 small pixels, example: extendcam.C
1918
1919 - added possibility to write data to memory (TTree) using MWriteRootFile
1920
1921 - added possibility to read a TTree stored only in memory by MReadTree
1922
1923 - new classes to deal with the interleaved calibration events:
1924 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1925
1926 - implemented filters to callisto to skip calibration events
1927
1928 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1929 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1930 the slices by statistics
1931 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1932 signal extractor without randomization
1933 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1934 with the signal extractor with randomization (extraction window is
1935 randomly fixed)
1936 The three kind of pedestal is not yet implemented (for speed reasons) as
1937 long as nobody really needs it:
1938 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1939 extracted with the signal extractor with randomization
1940
1941 - callisto now finds the pulse position in the data automatically
1942
1943 - implemented data reduction in calibrated data by reducing the precision
1944 of the stored floating point values (pedestal, rms and signal) to
1945 roughly 0.5%
1946
1947 - fixed showplot to make file format conversion (eg. converting a
1948 status display stored in a root file into a postscript file) in
1949 batch mode possible:
1950 showplot -b --save-as-ps[=outfile.ps] infile.root
1951
1952 - Allow class names as part of filter rules, eg
1953 (MFSupercuts) && (MHillas.fSize>100)
1954
1955 - fixed a lot of stuff to allow all programs to process MonteCarlo
1956 camera files.
1957
1958 - enhanced possibility to debug reading of resource file
1959
1960 - MDataChain should handle priorities of operator more
1961 accurate now
1962
1963 - completely revised the container in which the signal is stored
1964 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1965 * the new implementation is faster and
1966 * needs less storage space
1967
1968 - FIRST version which can process Monte Carlos through the
1969 whole chain of programs (callisto, star, etc)
1970
1971 - implemented new image parameters for the border length of
1972 the shower image (MNewImagePar2)
1973
1974 - implemented wobble-mode in ganymed
1975
1976 - new class (MJOptimize) taking care of all optimization processes
1977
1978
1979
1980 *** Version 0.8.6 (2004/10/05)
1981
1982 - New combined signal and time extractor
1983 MExtractTimeAndChargeDigitalFilter
1984
1985 - The Report for the trigger section in the CC run summary has been
1986 updated, and now the IPRs (Individual Pixel Rates) are available.
1987
1988 - new macros for database interaction: filldotrun.C, filldotrbk.C
1989
1990 - added new program which can convert colored output which was redirected
1991 into a file back into colored text (for example to display it with
1992 more): showlog
1993
1994 - added new program to display an MStatusArray of plots (stored with
1995 MStatusDisplay) from a file: showplot
1996
1997 - Added support for Sequences (MSequence). Sequences are blocks of run
1998 files containing the same calibration and belonging to the same
1999 source
2000
2001 - Added a new task (MTaskEnv) which can be used in setup files to switch
2002 between different tasks (for example to choose a signal extractor)
2003
2004 - Implemented automatic file splitting in MWriteRootFile
2005
2006 - After image cleaning an island index is assigned to all used pixels.
2007 The index corresponds to the order of the islands in size.
2008
2009 - added a cleaning which takes signal height _and_ arrival time into
2010 account: probability cleaning (for more details see MImgCleanStd)
2011
2012 - added a cleaning which takes takes the absolute number of photons
2013 times the area ratio as cleaning level
2014 (for more details see MImgCleanStd)
2015
2016 - Changed calculation of image parameters such, that it can be done
2017 for all used pixels or the pixels with a defined island index only
2018
2019 - implemented new image parameters displaying the number of islands,
2020 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2021
2022 - event display in executable changed to support also calibrated files
2023 (done with MJCalibrateSignal)
2024
2025 - added program doing the calibration and the signal extraction
2026 and signal calibration: callisto Most part of the setup is done
2027 by a resource file: callisto.rc
2028
2029 - implemented support for pixels with negative IDs (Raw file format
2030 version 4)
2031
2032 - implemented an new option in merpp (--auto-time) to get the time
2033 range for cc and/or caco data from the run header of the raw data
2034
2035 - New star-program (star and MJStar). Taking calibrated data from
2036 callisto/MJCalibrateSignal as input. The setup is done through
2037 a resource file: star.rc
2038
2039 - Added possibility to setup the eventloop in the mars-executable
2040 Camera Display by a resource file: mars.rc
2041
2042 - The the mars-executable Camera Display can now also read
2043 calibrated data files written by callisto/MJCalibrateSignal
2044
2045 - Added a new class which can calculate the source position in
2046 the camera from a pointing model known to be correct and
2047 the pointing model used for observations (MSrcPosFromModel)
2048
2049 - added a new version of the class calculating the effective on-time
2050 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2051 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2052 MHTimeDiffTheta.
2053
2054 - added the possibility to count how often a signal is above (or
2055 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2056 can replace MHTriggerLvl0)
2057
2058 - added ore convinient ways to set the axis-titles of your histograms
2059 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2060 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2061
2062
2063
2064 *** Version 0.8.5 (2004/08/06)
2065
2066 - new Signal Extractors: MExtractFixedWindowSpline
2067 and MExtractAmplitudeSpline
2068
2069 - implementes interleave in merpp to be able to merpp parts of a file
2070
2071 - implemented force-functionality to merpp
2072
2073 - star display to display star catalogs (MAstroCatalog)
2074
2075 - star display to 'mirror' stars to the camera (MAstroCamera)
2076
2077 - implemented a new cleaning option which allows cleaning scaled with
2078 the real ratio of the rms depending on the pixel size, not only the
2079 square root of the pixelsize (MImgCleanStd, MCameraData)
2080
2081 - removed obsolete MBlind* classes
2082
2083 - Signal extractor taking the AB flag into account implemented (this makes
2084 an odd number of slices for signal extraction possible
2085 (MExtractSignalABcorr)
2086
2087 - implemented a class extracting the pedestal from the raw-data (events)
2088 itself using empty lo-gain (MpedCalcFromLoGain)
2089
2090 - Added mean values to MPedPhotCam
2091
2092 - Added Makefile for Darwin (this OS is NOT officially supported!)
2093
2094
2095
2096 *** Version 0.8.4 (2004/04/19)
2097
2098 - new fast arrival time extractor using cubic splines:
2099 MExtractTimeFastSpline
2100
2101 - implementes multi-argument support in MDataChain
2102 ("pow(a, b)")
2103
2104 - implemented double reference support in MDataChain
2105 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2106
2107 - added support in MF for expressiond like
2108 "MHillas.fWidth<2*<MHillas.fLength"
2109
2110 - MDataChain is now able to support variables like [0], [1], ...
2111 which can be used in fit functions as parameters. The interface
2112 is implemented through the new virtual function
2113 MParContainer::SetVariables
2114
2115 - added new class MArrivalTimeCam/MArrivalTimePix:
2116 Storage containers to hold the ArrivalTime of the camera/pixel
2117
2118 - added new classes for the calibration of relative arrival times:
2119 MCalibrationRelTimePix and MCalibrationRelTimeCam
2120
2121 - added new classes to extract the signal of the blind pixel and the
2122 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2123
2124 - added new classes for the bad-pixels treatment (MBadPixels*)
2125 which are more powerfull than the old ones (MBlindPixel*)
2126 and will replace them.
2127
2128 - added filter against cosmics: MFCosmics
2129
2130 - added new class MArrivalTimeCalc2:
2131 Calculates the arrival time as the signal weighted mean of the time
2132 slices in the maximum window
2133
2134 - added a new macro call pointspreadfucntion.C that fits with a 2D
2135 gaussian the DC spot for an star. It gives you the RMS of
2136 the PSF and the center of the star, very useful for misspointing
2137 studies.
2138
2139 - added support for multi-telescope camera files. Added classes
2140 MStereoCalc and MStereoPar, classes to calculate and store shower
2141 parameters calculated from the data of two telescopes, for the MC
2142 studies regarding the MAGIC clone.
2143
2144 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2145 MC data calibrated in photons instead of ADC counts.
2146
2147 - added three macros to show the calibration and analysis chain of
2148 MC data. The macro starmc.C does both calibration and analysis, producing
2149 an output containing Hillas parameters for each event. The macro
2150 mccalibrate.C does just the calibration and writes out a file containing
2151 pixel information in photons instead of FADC data. The macro starmc2.C
2152 reads in such a file and produces an output with Hillas parameters.
2153
2154 - added MPedPhotCalc to compute pedestals in units of photons, see
2155 macro pedphotcalc.C
2156
2157 - added all class to perform the calibration, see macro calibration.C
2158
2159 - added class MFFT to perform Fast Fourier Transforms
2160
2161 - added class MSimulatedAnnealing to perform simulated annealing
2162 minimizations
2163
2164 - added new macro bootcampstandardanalysis.C which holds the skeleton
2165 of the analysis chain discussed in the december bootcamp.
2166
2167 - added support for DAQ raw data file format V2
2168
2169 - implemented an arbitrary time stamp for the events from raw-data
2170 files with file version<3. It is calculated from the run number,
2171 the date of start and the FADC clock tick from the first module
2172
2173 - implemented the correct decoding of the event time-stamp
2174 coming from the DAQ for raw-data files with file-version>2
2175
2176 - added a new classes storing the pedestals in units of photons:
2177 MPedPhotPix, MPedPhotCam
2178
2179 - added support for DC current files from the camera control
2180
2181 - added support for start- and stop-time when merpping report files
2182
2183 - added MReportCC storing the weather data from the CC-REPORT
2184
2185 - added class to fill trainings and test matrices (MTFillMatrix)
2186
2187 - added a filter performing a software trigger (MFSoftwareTrigger)
2188
2189 - Added classes to perform parts of the standard analysis (Jobs):
2190 + MJPedestals
2191 + MJCalibration
2192 + MJExtractSignal
2193 Note: All of them are preliminary!
2194
2195 - Added Iterator to iterate over files giving only the run-number
2196
2197 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2198 the evolution of a sector vs time
2199
2200
2201
2202 *** Version 0.8.3 (2003/12/05)
2203
2204 - adapted Random Forest classes to allow the use with MC
2205 multi-telescope files which can be produced with the coming
2206 camera version 0.7.
2207
2208 - added classes to read and interprete central control report files
2209 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2210
2211 - enhanced merpp (the executable) to support .raw and .rep files.
2212
2213 - added classes for light calibration (MCalibration* and
2214 MHCalibration*) by Markus Gaug. Further work has to be and will
2215 be done soon.
2216
2217 - Added a preliminary 'synchronizer' (MReadReports) which will
2218 replace MReadMarsFile as soon as it is finished.
2219
2220 - Added a tutorial macro demonstrating how report files are merpped
2221 and how they can be read from the root file in the correct order
2222 of time (readrep.C)
2223
2224 - Added a generalized histogram (similar to MH3) called MVsTime
2225 which allows to plot variables (or rules - MDataChain - of
2226 variables) vs time. For an example have a look at tempvstime.C.
2227
2228 - Changed the name of the event trees:
2229 + Events --> Events
2230 + PedEvents --> Pedestals
2231 + CalEvents --> Calibration
2232
2233 - changed name of MTime in the event trees from MRawEvtTime to MTime
2234
2235 - added displaying the sector indices to the mars event display
2236
2237 - Magic Online Analysis (MOnA) implemented in a first version
2238 (see mona.cc, MOnlineDump and MOnlineDisplay)
2239
2240 - added classes to calculate event rate
2241 (preliminary: MEventRateCalc, MEventRate)
2242
2243 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2244
2245 - added classes dealing with the telescope pointing position (MPointing*)
2246
2247 - implemented the 'final' Mars time stamp based on some experiences with
2248 the new 'Synchonizer'
2249
2250
2251
2252 *** Version 0.8.2 (2003/11/10)
2253
2254 - accelerated standard analysis by a factor of 6-8 ...
2255 + doing precalculations in MGeomCam for the pixel area ratio
2256 + creating a look up table for the single pixels in MCerPhotEvt
2257
2258 - added task to calculates weights in case you want to 'change'
2259 the energy spectrum of a monte carlo file
2260 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2261
2262 - added a new executable star which implements the
2263 star.C macro as precompiled executable. Currently a flexible
2264 setup is not possible, but a 'input card' setup will follow.
2265
2266 - Starting to implement Multi-Telescope-Support based on the
2267 upcomming camera version 0.7. The base for a general support
2268 is implemented and the star-functionality is proven to work.
2269
2270 - Replaced Event-Display in and Camera-Display in the Mars GUI
2271 executable by a more convinient display base on MStatusDisplay.
2272
2273 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2274
2275
2276
2277 *** Version 0.8.1 (2003/10/20)
2278
2279 - added signal subtraction for pure on data by means of fitting
2280 the background in the off region or by performing a combined
2281 signal/background fit. Provides necessary histograms for
2282 obtaining energy spectra and a light curve.
2283
2284 - added classes to perform and study the selection of the
2285 2nd Level Trigger on MC data (example in triglvl2.C macro)
2286
2287 - added pedestal calculation
2288
2289 - implemented "democratic cleaning" (tail cut value proportional
2290 to pixel area) according to Wolfgang's suggestion.
2291
2292 - added Sigmabar treatment (calculation and basic histogramming)
2293
2294 - added basic routines to apply padding
2295
2296 - added first implementation of MARS-based source visibility plotter
2297 (needs to be linked against slalib, preliminary version)
2298
2299 - enhanced functionality of data chains: random numbers, conversion
2300 functions and access to MHMatrix objects
2301
2302 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2303 numbers under certain circumstances (runs with 0 events included)
2304
2305 - fixed a bug in the general filter MF (didn't work on some systems
2306 at all)
2307
2308 - fixed a bug in chaining files, which caused the analysis to crash or
2309 ignore files
2310
2311 - implemented more geometry classes describing the parameters used
2312 to simulate the PMT camera
2313
2314 - added new Monte Carlo classes containing the setup of the different
2315 programs in the MC chain.
2316
2317 - added a (preliminary) general task to evaluate chi-square of a given
2318 parameter in an eventloop.
2319
2320 - first implementation of a container describing the observatory
2321 location (Long, Lat, etc)
2322
2323 - added Random Forest - method for g/h-separation
2324
2325 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2326 (this means, that it is compiling, but not yet fully tested)
2327
2328 - added a new status display which can show the present status
2329 of histograms while an eventloop is running (MStatusDisplay,
2330 an example can be found at status.C)
2331
2332 - reorganized directories:
2333 classes describing the image --> mimage
2334 classes containing Monte Carlo Histograms --> mhistmc
2335 classes for Random Forest method --> mranforest
2336
2337 - added (event-)weights to fill histograms
2338
2339 - colors in logging output to screen
2340
2341 - changes to the Image Parameter declaration:
2342 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2343 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2344 + MHillasExt now derives from MParContainer instead of MHillas
2345 --> Files written with the old definition are more or less unreadable
2346
2347 - reading of reflector files
2348
2349 - display data from reflector files in the camera
2350
2351 - implemented currents (and display them in the camera)
2352
2353 - logarithmic scale in camera
2354
2355 - added class to iterate through directory contents (MDirIter)
2356
2357
2358
2359 *** Version 0.8 (2002/11/18)
2360
2361 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2362
2363 - corrected 48(!) wrong entries in the Next Neighbor table of the
2364 Magic Camera (all in the inner part of the outer ring, mostly
2365 missing a single NN)
2366
2367 - Fixed a bug in the table describing the Next Neighbours of the
2368 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2369 have any neighbour)
2370
2371 - changed trigrate.C: now it calculates the pure NSB triggers from
2372 a camera file (generated with no showers), so there is no need
2373 to introduce them by hand in the BgR array (for more details
2374 please ask Abelardo)
2375
2376 - added MHHadronness (and MHadronness) as a general facility to evaluate
2377 the quality of a gamma-hadron seperation method
2378
2379 - changed MWriteAsciiFile to accept rules (MDataChain)
2380
2381 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2382 must be replaced by calles to MWriteAsciiFile::AddColumn and
2383 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2384 changed.
2385
2386 - Implemented generalized event-matrices (one row per event)
2387 (MHMatrix)
2388
2389 - implemented the one dimensional composite probabilities
2390 (MHCompProb, MCompProbCalc, comprob.C)
2391
2392 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2393 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2394
2395 - Added a camera display displaying the pixel numbers to the
2396 event display gui.
2397
2398 - Added Monte Carlo Informations to event display gui
2399
2400 - Changed the camera display to display the pixel numbering
2401
2402 - Added three buttons to the camera display to change the palette
2403
2404 - Added the number of used and core pixels after image cleaning
2405 to MHillas
2406
2407 - Changed the algorithm used in MHillas according to TDAS 02-03
2408
2409 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2410
2411 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2412
2413 - Added fCosDeltaAlpha to MHillasSrc
2414
2415 - The numbers of photons used to calculate fConc and fConc1 in
2416 MHillasExt are now scaled with the pixel size, so that one get
2417 a four times smaller value for the bigger pixels in the outer ring.
2418
2419 - added new task to smooth the camera contents (MCameraSmooth)
2420
2421 - added possibility to use interpolated pixel values for blind pixels
2422 instead of removing it completely from the analysis
2423
2424 - Implemented the possibility to save the whole eventloop with
2425 its setup to a file. This information can be read and from
2426 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2427 and MEvtLoop::MakeMacro. If you find something not working, please
2428 report - this stuff is still in a beta phase.
2429
2430 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2431 file having crab starfield, but also for all following files - fixed
2432
2433 - MTaskList::PrintStatistics can now be instructud to print also the
2434 title, too: use PrintStatistics(0, kTRUE)
2435
2436 - Changed the image cleaning so that pixels with to many 'used'
2437 neighbors are left used (to get rid of 'holes' in events)
2438
2439 - Introduced more output to the camera displays
2440
2441 - Added an array of histograms (eg one hist per run), MHArray
2442
2443 - Added a _preliminary_ version of the reader for CT1 PreProc files
2444 (MCT1ReadPreProc)
2445
2446 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2447 (thanks to Raquel)
2448
2449 - added the first energy estimator (MEnergyEstParam, estimate.C,
2450 estfit.C) using a parametrization
2451
2452 - Added some new Monte Carlo paremeter containers used to store
2453 setup information from the MC chain (MMcConfigRunHeader,
2454 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2455
2456
2457
2458 *** Version 0.7 (2002/04/30)
2459
2460 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2461 the pedestal mean value was saved incorrectly. For files from
2462 this versions we substract 0.5 from the pedestal mean.
2463 WARNING: This may effect your results, so don't wonder...
2464
2465 - First implementation of an algorithm using only triggered events
2466 for the collection area calculation
2467
2468 - Ascii Output can now also be used for parameter containers which
2469 doesn't overload MParCointainer::AsciiWrite
2470
2471 - The Ascii Output is now also capable of writing single data members
2472 of one container
2473
2474 - You are now able to change the order of the values written to the
2475 ascii file
2476
2477 - You can now specify a conversion factor for each data member written
2478 to an ascii file. This may be usefull to change the units of the
2479 data member (eg. degrees instead of millimeters in case of the
2480 hillas parameters)
2481
2482 - Replaced old MHillas by a new structure which allows you to extend
2483 the parameters stored in MHillas very easily:
2484 see MHillas and MHillasExt
2485
2486 - Added classes to handle source dependancy of image parameters:
2487 see MHillasSrc
2488
2489 - Added container (MBinning) to have a standard input for the binning
2490 in different histograms (eg. the Energy bins should be the same in
2491 all histograms)
2492
2493 - Changed Hillas histograms from mm to deg
2494
2495 - Added the flexible binning to the hillas histograms
2496
2497 - Added a filter for the alpha parameter (MFAlpha)
2498
2499 - It is now possible to write single data members of a class object to
2500 an output stream instead of the whole container only
2501
2502 - Added a generalized filter for a data member:
2503 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2504
2505 - Added a generalized Filter parser for more difficult filter rules
2506 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2507
2508 - Added new Monte Carlo histograms:
2509 MHMcEnergyImpact and MHMcEfficiency
2510
2511 - Added many new histograms needed for the flux calculation.
2512
2513 - Added a generalized histograms which can fill and show up to three
2514 data members in either a one-, two- or three-dimensional histogram, eg:
2515 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2516
2517 - Added:
2518 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2519 * calculation of <Theta> as a function of time (MHThetabarTime)
2520 they are needed in the flux calculation in
2521 order to select for a given bin in Theta (or time) the appropriate
2522 effective collection area, which is assumed to be given as a function
2523 of Theta and the true energy
2524
2525 - Added calculation of the migration matrix in the energy
2526 (MHMcEnergyMigration):
2527 the migration matrix describes the migration from the true (E_true)
2528 to the estimated energy (E_est); it is needed to determine the
2529 distribution of E_true from the measured distribution of E_est
2530 by unfolding
2531
2532 - changed the color palette in the camera display to DeapSea.
2533
2534
2535
2536 *** Version 0.6 (2002/01/15)
2537
2538 - Introduce the option of disable pixels (MBlindPixels and
2539 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2540 able to deal with Star Field NSB.
2541
2542 - Fixed a bug in the pedestals substraction
2543
2544 - Introduced verbosity levels
2545
2546 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2547
2548 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2549 work correctly (thanks to Abelardo)
2550
2551 - Introduced correct treatment of the diffuse Night Sky Background
2552 and NSB (MMcPedestalNSB)
2553
2554 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2555
2556 - Introduced MMcRunHeaders which contains monte carlo run informations
2557
2558 - Added a 'Print'-Task (MPrint) which calls the Print function
2559 of a parameter container for each event
2560
2561 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2562
2563 - changes to be more efficient with root 3.02/06
2564
2565 - root 3.02/06 fixes:
2566 + the memory leak when reading MRawEvtData
2567 + loosing more time than necessary to update the progress bar
2568
2569 - MWriteAsciiFile is now capable of writing more than one container
2570 in a line. For example: To be able to write Monte Carlo and
2571 Hillas values (energy and alpha) in one line.
2572
2573
2574
2575 *** Version 0.5 (2001/11/06)
2576
2577 - Added new GUI functionality (Analysis)
2578
2579 - Added a camera display to be able to display events in the camera
2580 together with the calculated hillas ellipse
2581
2582 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2583 object at any state of the analysis, so that the output are several
2584 states
2585
2586 - Fixed a bug in the collection area error calculation
2587 (Thanks to Ciro and Abelardo)
2588
2589 - Fixed a bug which causes merpp to crash in some environments
2590
2591 - Implemented auto enabling scheme for Branches to speed up reading
2592 a lot (see MReadTree and MTask)
2593
2594 - Fixed a bug in the Histogram classes which caused histograms to
2595 be written to a file by MWriteRootFile without request
2596
2597 - changed the object I/O from the old stylish root I/O to the new
2598 'auto evolution scheme' This was done only for classes which are not
2599 yet used in Monte Carlo files, so that these files are still readable.
2600
2601 - Added support for a progress bar in MEvtLoop and MReadTree
2602 (see the Analysis Window in Mars for an example)
2603
2604 - Fixed a bug in the package creation which disturbed the conversion
2605 between a mars version unpacked from a tar file and the repository.
2606
2607 - Changed the code to writer merpped (converted into root format)
2608 raw files, to get faster (around 10%)
2609
2610
2611
2612 *** Version 0.4 (2001/09/20)
2613
2614 - This release is made to compile on a root version >= 3.00
2615
2616 - Fixed a bug which causes MReadTree to read the first file only
2617
2618 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2619
2620 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2621
2622 - Added a task to write several container to a root file (MWriteRootFile)
2623
2624 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2625
2626 - Added calculation of the collection area (MMcCollectionAreaCalc)
2627
2628 - fixed some bugs in the Hillas calculation
2629
2630 - added filters to be able to control the task execution dependent on
2631 a parameter (for example: the number of level 1 triggers in a MC-file)
2632
2633
2634
2635 *** Version 0.3 (2001/04/23)
2636
2637 - Many demo macros added
2638
2639 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2640
2641 - Hillas Calculation added
2642
2643 - Standard image cleaning available
2644
2645 - MReadTree is now able to handle more than one file
2646 (Remark: of the same structure)
2647
2648 - Now we are able to display events in a first version of the
2649 Camera event display. To do this we must run the macro
2650 "macros/readCT1.C" to read data from CT1.
2651
2652
2653
2654 *** Version 0.2 (2001/01/24)
2655
2656 - First Implementation of a Gui to read the raw data. Start the
2657 gui with the command mars.
2658
2659
2660
2661 *** Version 0.1 (2000/12/20)
2662
2663 - First official release 0.1
2664
2665 - Changes:
2666
2667 + changed calling style of MRawPixelIterator from do...while to
2668 while-loop
Note: See TracBrowser for help on using the repository browser.