source: trunk/MagicSoft/Mars/NEWS@ 8787

Last change on this file since 8787 was 8787, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 112.3 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5;general
6* fixed GroupBy options in plot*.C macros
7* only display KVA points (not the Tuorla points) in plotoptical.C
8* all programs now allow to add resources to the ones from the resource
9file or overwrite them from the command line. This can be done like this
10::ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
11:if something seems to be wrong you can debug what the program is doing
12using the option --debug-env=3
13* increased the diversity of debug levels. That also means that with -v3
14you get now less output, i.e. only the output which is important for
15an analysis. To get more output which helps for debugging try 4, 5 and 6.
16* fixed a problem in the task synchronizing the reading of the reports
17and the data stream. The effect was that in some circumstances the last
18events of some trees could have been skipped. Since this is only a
19very tiny part of the data no severe effect to your analysis results
20is expected.
21* Dataset file now allow to include the sequence file directly within
22the dataset file and also allow to exclude single runs from the dataset.
23(for more details see Class reference of MDataSet)
24* Sequence files now allow for excluding runs from the analysis
25(for more details see Class reference of MSequence)
26* added code to process the sum-trigger flag
27
28;callisto
29* in the pedestal processing now at least 50 processed events are
30required for succeeding.
31
32;ganymed/sponde
33* Now data points are even shown correctly if they have error bars larger
34than one sigma. Points with null or negative significances are omitted.
35
36;sponde
37*fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
38
39
40 *** Version 2.0 (2007/09/03)
41
42 - database: the position used for the pulse pos check was missing
43 in the callisto output and could thus not be filled into the DB.
44 Also the old values seemed not exactly the PulsePos used for
45 teh check.
46
47 - general: Resource file now allow an Include-Resource, i.e. you can
48 read a resource file with default settings, include it in your
49 resource file and overwrite the settings in your file. More than
50 one include file is allowed. Inclusions can be iterative.
51 Include: mydefaults.rc yourdefaults.rc
52 The resources in the first file have higher priority than the
53 second file.
54
55 - general: Now the output files (calib*.root, etc) also contain the
56 resource file (to check it open it in the TBrowser and choose Print()
57 from the context menu)
58
59 - general: Dataset files now allow to overwrite the default path
60 to search for sequence and data files. Note, that the program
61 option and individual resources will overwrite it. For example:
62 SequencePath: /magic/montecarlo/sequences
63 DataPath: /magic/montecarlo/star
64
65 - general: Fixed a problem with variables in MDataPhrase. It seems
66 that only optimdisp (didn't work) was effected.
67
68 - general: Some improvements to the optim and train processing. For
69 example the ststud window now got a proper title.
70
71 - general: The "Status Display: " was removed from the window title
72 within an Eventloop.
73
74 - general: added a new flexible histogram-class (MHn) which can be used
75 for example in testing after optimizations or training to produce
76 user defined histograms.
77
78 - general: The Random Forest now allows attaching an evaluation
79 function which is applied to its output. This allows to train
80 on whatever you like (eg. train on log10(energy), but return
81 energy)
82
83 - general: The Random Forest training of energy (trainenergy.c) and
84 disp (traindisp.C) has been improved by more graphical output to
85 judge the result.
86
87 - general: The training of energy (trainenergy.C) has been improved
88 a lot by training on a different quantity than energy. It gives
89 a result which is highly independant of the source spectrum
90 and shows lower bias than all other options.
91
92 - general: Dataset files are allowed to contain collections of
93 datasets. For more details see the class reference of MDataSet.
94
95 - general: The default WobbleMode in a datset file now (if not
96 overwritten) is "auto", i.e. wobble mode is set if the dataset
97 doesn't contain off-sequences.
98
99 - merpp: Merpp can read file format version 9 now. Please realize
100 that for file format version 9 the extraction range is different
101 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
102 the first and last 15 slices have been removed from all MUX data.
103
104 - mars: Similar to writing movies you can now select events which
105 should be displayed in your display. Therefore add the following
106 lines to your mars.rc:
107 MFEvtNumber.FileName: ganymed00223552.root
108 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
109 The input file can be a ganymed-file after (ganymed*.root) or
110 before (ganymed*-summary.root) file. For example to select all events
111 from your on sample after cuts (excluding the ThetaSq cut) use
112 MFEvtNumber.Selector: DataType.fVal>0.5
113 To show all events from your on-sample after quality cuts
114 use the summary file instead.
115
116 - mars: new ways to call mars are implemented. Instead
117 of calling
118 mars filename.root
119 you can now also use
120 mars sequence.txt
121 or
122 mars sequence.txt inputpath
123 or replace sequence.txt by the sequence number if the default
124 sequence file should be used.
125
126 - mars: The default size has been increased
127
128 - mars: There are two new heckboxes which allow to switch off
129 the calculated image parameters
130
131 - callisto: was broken for MCs... fixed.
132
133 - callisto: improved calculation of spline coefficients a lot. This
134 leads to a further improvement of the event rate calibrating MUX
135 data of about 15% (175evt/s instead of 150evt/s)
136
137 - callisto: finally the raw data we read is now real 16bit (with
138 10bit precision) for MUX data and not a stripped 8bit number
139 anymore. Due to scaling of the numbers (without precision loss
140 into an [0-256[ range, the final numbers for pedestal, pedestalrms
141 and extacted signal don't change. However, at all places where
142 raw data is directly accessed (eg. saturation and variation
143 limits in the signal- and pedestal-extraction) the numbers
144 refer still to the data's 16bit range.
145
146 - callisto: The maximum arrival time difference used in the bad
147 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
148 for both, old FADC and MUX-FADC, data.
149
150 - callisto: Be aware that callisto is now calibrating the arrival time
151 in nanoseconds rather than time slices. Also all following tasks
152 have been changed to assume ns units now. If you star data
153 calibrated with an older version it might be necessary to adapt
154 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
155 to obtain optimal results. The plot in the PulsePos tab
156 will now be in ns, too. This might also mean that the Muon
157 analysis in star might not work as perfect as expected as long
158 as old files read in.
159
160 - callisto: The calibration constants of earlier updates got lost
161 somehow. All constants have been updated.
162
163 - star: The PSF is now determined from the profile of the ArcWidth
164 instead of arcwidth/radius. The old way gave to much weight
165 to the bins with low statistics. The reference lines have been
166 updated.
167
168 - star: For speed reasons events suitable for the muon analysis
169 are now also preselected by fConcCOG<0.1 which seems to be a very
170 good preselector for muons.
171
172 - star: is now calculating a new timing parameter the Slope along
173 the major and minor axis of the shower. Therefore a numerical
174 solution of a line-fit is used. To use MHillasExt.fSlopeLong
175 and MHillasExt.fSlopeTrans don't forget to multiply it with
176 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
177
178 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
179 have been removed from MNewImagePar. They have never been good for
180 anything.
181
182 - star: Implemented a new recursive algorithm which is supposed to be
183 faster. Also implemented new cleaning oiptions, which are:
184 + CleanLevel0:
185 The cleaning level above single core pixels can be kept
186 + KeepIsolatedPixels:
187 Define whether single core pixels should be kept
188 + TimeLevel1:
189 The coincidence window in nanoseconds to single used neighbors
190 + TimeLevel2:
191 The coincidence window in nanoseconds to two used neighbors
192 + PostCleanType:
193 MOde in which a time dependent post cleaning should be applied
194 0: No post cleaning
195 1: Require for each used pixels at least one used neighbor
196 within a time-window of CleanLevel1
197 2: Require for each used pixels at least two used neighbor
198 within a time-window of CleanLevel2
199 3: Require first two and second one used neighbor
200 within a time-window of CleanLevel1 and fCleanLevel2
201 respectively
202 + RecoverIsolatedPixels:
203 - recoveres isolated core pixels if they have a used neighbor
204
205 - mars/star: The new default cleaning is:
206 + CleanLevel1: 6.0
207 + CleanLevel2: 3.0
208 + CleanTime1: 1.75
209 + CleanTime2: 1.75
210 + PostCleanType: 3
211
212 - star/ganymed: The old spark-cuts have been replaced by new ones.
213 These new spark cuts have been cross checked with the sequences
214 84720 (before splitter), 101041 (after splitter) and 223539 (new
215 FADCs). In all cases they seperate pretty well, but of course not
216 perfect. Monte Carlos have suggested to tighten the cuts a little
217 bit further at low sizes. This has been done.
218
219 - ganymed: IMPORTANT - The spark cuts have been changed to match
220 all available data more or less well. This might mean that for
221 YOUR data there are still sparks visible.
222 Whenever you do an analysis you have to make sure that NO sparks
223 survive your cuts!
224
225 - ganymed: The old hadronness and size cuts have gotten new indices
226 (10, 11). The old indices 8 and 9 now mean an additional condition
227 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
228 If you want to switch off this cut just move the line far away enough,
229 e.g. by setting c[9] to -500. Please update your ganymed.rc files
230 accordingly!
231 The unit of c[9] is deg. It is the dist at which your cut will
232 cross the slope==0. The unit of the slope is ns/deg. So if
233 you readin files calibrated with an older Mars-version you
234 have to adapt the default value for c[9] to the FADCs:
235 - Multiply by two for the MUX FADCs (run number > 200.000)
236 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
237 - Multiply by 42 for the meaning of life (run number = 200.000)
238
239 - ganymed: The old Cut0 is now called CutQ and is calculated before
240 the source position is caluclated. If you need a quality cut
241 including source dependant data (be very carefull with this!)
242 you have to use Cut0 instead.
243
244 - ganymed: now properly supports three off regions in wobble mode.
245 It will be the default from now on in ganymed_wobble.rc. To change
246 the number of off-regions use
247 NumOffSourcePositions: 1
248 in your ganymed.rc. Also by default no off-theta cut will be done
249 anymore so that you will get a background level higher than the
250 signal level in your ThetaSq plot for ThetaSq>0.2.
251 Due to this be carefull changing the scaling mode away from
252 "None". You will underestimate your signal if your scale interval
253 is not properly set.
254 (Rem: ThetaSqN is no longer needed)
255
256 - ganymed: is now storing the events of all (on- and off-)
257 source positions even in the case of more than one off-source
258 position. This should allow sponde to work properly and the
259 energy estimation is done correctly in all cases (without any
260 "nearest position" trick)
261
262 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
263 with a real pointing model for the starguider is done, calibrated
264 with more than thousand tpoints taken from this date on.
265
266 - ganymed: was broken for Wobble-MCs... fixed.
267
268 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
269 has changed. Note that your old ganymed.rc will be incompatible
270 with the new algorithms! Please check the ganymed.rc files and
271 the class description of MFMagicCuts for more information.
272 It is recommended at the moment to use identical Disp-Parametrizations
273 for on/off- and wobble-mode. If cuts are optimized only
274 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
275 should be optimized. All other values should be kept as they are.
276 If you want to do an anylsis without timing a parameters, you can
277 switch off the timing cuts by seeting parameter 7 to a very small
278 value (eg. -99). To remove the slope parameter from the disp
279 paremtrization set parameter 8 to 0.
280
281 - ganymed: The distribution of observation time versus zenith
282 angle is now shown for off- AND on-data.
283
284 - ganymed: The contents of the source position plot are no longer
285 averaged, thus a lot of (fake) events between the two wobble
286 positions have disappeared.
287
288 - ganymed: There is a new tab "CutT" it contains the VsSize plots
289 with the CutT, whihc is defined in ganymed.rc, applied. It
290 is resonable to use your theta-cut for it, to see if there is
291 something strange (sparks!) in your signal-region.
292
293 - ganymed: To choose a dataset from a collection in a dataset file
294 use the new command line option "--dataset=12345"
295
296 - optim, sponde: should now properly support three off-regions.
297 Just produce your ganymed summary files with three off-regions.
298 optim and sponde will automatically get all off events from
299 all off-regions from this file. Please do not forget to
300 set the scaling in optimwobble.C properly:
301 fit.SetScaleUser(1./3);
302 it is not yet read in automatically (will follow soon).
303 In the case of fixed Scale you can also use
304 cuts.SetThetaCut(MFMagicCuts::kOn);
305 no off-cut needed.
306 Be carefull in case of three off-regions when switching on
307 scale mode. Make sure that the scale interval is set correctly.
308
309 - sponde: sponde.rc and sponde_onoff.rc are now idetical
310
311 - sponde: the resouce files have been rewritten with a lot of
312 comments and a well working parametrization for an energy estimator
313
314 - sponde: In the estimated energy versus monte carlo energy plot the
315 contents where exchanged.... fixed.
316
317 - sponde: the so called "accurate"-mode has been removed. It didn't
318 give any improvement in accuracy, only decreased execution speed.
319
320 - sponde: the so called "simple"-mode has been removed. It didn't
321 give any improvement in simple.
322
323 - sponde: the so called "refill"-mode has been removed. It was anyhow
324 not implemented.
325
326 - sponde: now checks whether the theta distribution of your on-data
327 and the theta-distribution of your Monte Carlo sample (after
328 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
329 sample is incomplete) execution is stopped. Execution can be forced
330 using the new option --force-theta. Use this option with care!
331
332 - sponde: Proper collection areas can now be constructed also from
333 Monte Carlo samples generated with different maximum impact
334 parameters. Note that in previous version you neither got
335 a warning or failure, nor was there any obvious sign that the
336 collection area was overestimated due to usage of files with
337 different maximum impact parameters.
338
339 - sponde: If MC files with different lower energy limits are used
340 the primary MC spectrum is artificially completed down to the
341 lowest energy used at all. WARNING: that this gives correct
342 collection areas ONLY if none of the events in this region would
343 survive your cuts at all.
344
345 - sponde: the output file now contains more information about
346 the spectrum (eg. the full 2D collection area histogram).
347 Note, that this information can only be written to the file
348 if it is stored automatically via command line argument.
349 If you only store the status display from within the display
350 the information is lost.
351
352 - sponde: added a new tab "Disp". It shows the residual of the disp
353 (Disp-Dist) versus several parameters and it is meant to judge the
354 quality of the disp estimator. In the ideal case the residual is zero
355 and doesn't depend on any variable. The tab is displayed after
356 CutQ and Cut0.
357
358 - sponde: added a new tab "Energy". It shows the residual of the
359 energy (lg(estimated energy)-lg(monte carlo energy)) versus
360 several parameters and it is meant to judge the quality of the
361 energy estimator. In the ideal case the residual is zero
362 and doesn't depend on any variable. In reality even a good estimator
363 can show residuals versus Monte Carlo energy. The tab is displayed
364 after all cuts.
365
366 - sponde: added a new tab "EventDist" showing the unweighted real
367 absolute number of events of your sample after cuts. This tells
368 you how many events with this energy you had in your MC files.
369 The same information you get from the error bars of the weighted
370 histograms, but this is less intuitive.
371
372 - sponde: The spectrum plots now show the crab- and 1553-spectrum
373 for comparison. It is not meant to show these curves in
374 publications, they are only for production.
375
376 - sponde: The OriginalMC tree with the events produced by corsika
377 is now processed only once
378
379 - sponde: Finally fixed most annoying bug, which has effected the
380 last bin of the collection area. It was the problem that binnings
381 of root histograms are from 1 to n (included) but there was a C-like
382 loop in sponde from 0 to n (excluded). Now the loop also includes
383 correctly under- and overflow-bins. The worse thing with this is,
384 that for the events in the highest bin not only the bin-content
385 was wrong, but also the weights applied to these events, which could
386 in pricipal effect also other parts of the distribution (eg. due
387 to energy estimation). Fortunately it effected only a few events
388 in most cases.
389
390
391
392 *** Version 1.2 (2007/05/14)
393
394 - database: The database now has two new values Unsuitable50 and
395 Unsuitable01. They express the number of pixels which are
396 unsuitable for more than 50%, respectively more than 1%, of
397 all calibrated event. It is a more accurate number than the
398 previously used numbers, because they only take the first
399 calibration (ignoring the interleaved calibrations) into account.
400
401 - database: The database now has two other new values UnsuitableMax and
402 DeadMax. They express the maximum number of pixels which were
403 unsuitable, respectively dead, during the sequence. Because
404 of high pedestal rms (cars passing) a few events with very high
405 numbers of unsuitable pixels can happen. Not to suffer from this
406 effect we don't take the highest 0.1% of the numbers into account.
407
408 - general: fixed a bug which caused callisto and star to stop working
409 properly because the callisto output was currupted
410
411 - general: a script called scripts/makemovie has been added which
412 simplified the process of producing several movies from a single
413 sequence with different setup.
414
415 - callisto: Some more code cleanup. Started to remove old obsolete
416 code from cvs.
417
418 - callisto: The extraction of the pedestal with the extractor was
419 not random. It seems that extracting at one position is still biased
420 (for example in the first or last slices we could still suffer from
421 switching noise) Now it is completely random.
422
423 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
424 pedestal files) individual pixels could be skipped due to high
425 variations. This was already the case for the pedestal extraction
426 from the lo-gains since the beginning and properly handled
427 there, but was introduced in the extraction from the pedestal files
428 a while ago. To calculate the average value it was still divided
429 by the number of events procesed not by the number of summands
430 really summed. This let to a pedestal which was a tiny amount too
431 small (for a few piels in the order of 0.1%). This led to an slightly
432 positive offset of the randomly extracted pedestal for a few pixels.
433 I doubt that this has a big effect on the result, because the effect
434 on the individual numbers is quite small. Due to this it is suggested
435 that you rerun your calibration to make sure you are without any
436 avoidable bias.
437
438 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
439 the median rms of the absolute arrival time and expressed in significance
440 levels. This replaces the old meaning of an abolute upper limit. An
441 absolute upper limit doesn't make much sense, because in our data
442 all arrival times are shifted at the same time (in fact it might be
443 a shift of the artificial trigger w.r.t. to the light flash).
444
445 - callisto: Added a new tab "BadPixTm" which shows the time evolution
446 of the number of unsuitable pixels over the whole sequence. This
447 is usefull mainly to judge if an intermediate calibration had
448 problems.
449
450 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
451 of the number of dead pixels over the whole sequence. Dead pixels
452 in this context are unmapped pixels, i.e. pixels which could not
453 be interpolated, and thus are ignored in the further analysis.
454
455 - callisto: It is now possible to use the position of the maximum
456 of the spline as arrival time instead of the leading edge even
457 when using the integral for the signal. Therefor set the extraction
458 type to kIntegralRel ("IntegralRelative") and the relative height
459 ("HeightTm") to -1:
460 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
461 MJPedestalC1.ExtractSignal.HeightTm: -1
462
463
464
465
466 *** Version 1.1 (2007/04/27)
467
468 - general: The new class MGeomCamDwarf contains the camera geometry
469 for our prefered Dwarf camera and can be used to create general
470 geometries of roundish or hexagonal cameras.
471
472 - mars: The default cleaning is now abolute 8.5/4.0.
473
474 - mars: The resource file mars.rc now contains examples for MUX data
475
476 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
477 data containing only 10-bit information is still cooked down to
478 8-bit, by cutting away the lowest 8-bit.
479
480 - merpp: When reading raw data the data is now stored in a single
481 array. The lo-gain array is obsolete. The interface stays the same.
482
483 - callisto: To process the new MUX data use the resource file
484 callisto_mux.rc
485
486 - callisto: The -root and -raw options to read merpped raw data have
487 been removed
488
489 - callisto: If the -mc option is given the sequence-name can now be
490 replaced by the MC sequence number
491
492 - callisto: If the sequence file contains "MonteCarlo: Yes" the
493 -mc option can now be omitted
494
495 - callisto: Started further simplification by removing obsolete
496 dependancies on MCalibIntensity*Cams.
497
498 - callisto: removed unsused intensity calibration from MJCalibration
499 for further simplification
500
501 - callisto: for simplification removed references to
502 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
503 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
504 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
505 (this should at minimum change nothing at all, and at maximum
506 improve thing if these containers where somewhere not handled
507 properly)
508
509 - callisto: Added the option to write an event movie. Please use
510 this option with care (huge files) but exessively to understand
511 our events. For further documentation please refer to the
512 IACT wiki
513 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
514
515 - callisto: Improved binning for the pulse position check histogram
516
517 - callisto: The code calculating the pulse position checknow takes
518 the pedestal into account
519
520 - callisto: The arrival time is now stored with full precision this
521 helps to get rid of artefacts in histograms. For the signal this
522 is not necessray because it is displayed in log-scale anyhow
523
524 - callisto: Fixed a problem with internal exclusions. Pixels which
525 have once been marked as unsuitable didn't get the necessary
526 histograms filled anymore to be rechecked with each interleaved
527 calibration.
528
529 - callisto: The relative arrival time resolution (the rms of the
530 relative arrival time offset) is now checked against its
531 median and the median deviation, instead of the average
532 plus an absolute offset.
533
534 - callisto: The relative arrival time offset is now calculated
535 w.r.t. its median not w.r.t. to an artificial reference pixel.
536
537 - callisto: The relative time calibration now marks pixels with
538 outlaying offset as unsuitable
539
540 - callisto: The interleaved relative time calibration has been switched
541 on. The advantage is that pixels which are marked as outliers
542 now can recover. An improvement over time is not expected, because
543 the relative time calibration seems stable.
544
545 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
546 option can now be omitted.
547
548 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
549 or the option "-mc" is specified as default the monte carlo datacenter
550 paths (/magic/montecarlo/...) are used if not overwritten in the
551 dataset file.
552
553 - ganymed: The output files now contain run- and event-number for all
554 events, accessible as RunNumber.fVal and EvtNumber.fVal
555
556 - ganymed: Added a plot showing the source position in the camera also
557 for wobble mode
558
559 - ganymed: In addition to the existing task which can be setup to
560 be executed after Cut1 a final task called "EstimateEnergy"
561 has been added, executed before writing the final output
562 (ganymed00000000.root). The task setup in all three cases
563 can be choosen individually. (For all three(!) cases you
564 can for example choose MRanForestCalc. For examples see all
565 sponde*.rc and all ganymed*rc)
566
567 - ganymed: If a container "MEstimatedEnergy" is found in the
568 parameter list (eg. because it was setup by MEstimateEnergy)
569 it will be written to the output file.
570
571
572
573 *** Version 1.0 (2007/02/16)
574
575 - database: Website to plot values from the database has been added.
576
577 - database: The rate of spark events as found by star is now kept
578 and the rate after cleaning is now with spark events subtracted
579
580 - general: The changes to the interpretation of phrases lead to
581 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
582
583 - general: Added example files how you can create your own calendar
584 (eg. as christmas present) with Mars. Just run
585 root macros/tutorials/calendar.C
586
587 - general: Added a possibility to display grouped data in the plotdb.C
588 macro (and similar macros). This allows to plot hourly, nightly,
589 weekly, monthly and yearly averages.
590 For more details see the plotall function of the macro
591
592 - general: fixed the error display of the camera display. It showed
593 wrong results.
594
595 - general: fixed a memory leak when reading many MStatusDisplays
596
597 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
598 between a spherical and a parabolic mirror
599
600 - callisto: We have a new pulse position check which takes the properties
601 of the extractor automatically into account. So no need to set
602 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
603 left is done. If possible the lo-gain extraction start and hi-gain
604 extraction end is changed accordingly. If no proper extraction range
605 can be set (hi-gain too much to the left) an error is raised.
606
607 - callisto: New swapped pixels have been found and corrected
608
609 - callisto: Redone the signal extraction this includes:
610 + Unified the algorithms to extract the pedestal for all pedestal
611 extractions done
612 + Unification of hi- and lo-gain into one array
613 + Unification of hi- and lo-gain extraction for Spline and
614 Digital Filter (means now exactly the same algorithm is used,
615 not a copy-and-pasted one)
616 + Store pedestal subtracted data in a common place
617 + Improved extraction algorithms. If the algorithms search a
618 maximum but don't find one they don't return the maximum anymore
619 + Improved the extraction such that a information for signal
620 and time which is consistent is returned
621 + replaced the numerical spline with a (not slower) analytical
622 solution
623 + Lowered the saturation limit from 250 to 245 to make sure that
624 we are far away in all pixels from problems with the clock-noise
625 + The start of the lo-gain extraction is calculated from the hi-gain
626 arrival time. In case of saturation an estimation is used.
627 + the hi-gain window was extended to slice 16. This allows extraction
628 of very late pulses in single pixels or of huge hadron showers.
629 + Now uses the lo-gain extraction range for pedestal extraction,
630 not the hi-gain range in the lo-gain
631
632 - callisto: New hi-/lo-gain calibration constants have been produced
633 for all periods from the statistic of the whole period. They are
634 now used automatically depending on the periods. The old constants
635 where deviation in avarega about 2%-3%. The constants are very
636 stable from period to period (<<1%) except for exchanged channels.
637 In a few cases the constants used so far were off by 1%-2% (maybe
638 temperature effects?)
639
640 - callisto: To gain obsolete space we do not write the
641 MPedestalFundamental anymore. Also calibration and bad pixel
642 treatment is not done for it anymore because it has never been used.
643
644 - callisto: Fixed a bug in the seuqence handling which caused the
645 light condition to be ignored
646
647 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
648 basically the same as "Cleaned" but the distribution devided into
649 the events fullfilling a spark cut or being rejected by it.
650 This cut can be changed from star.rc (see example inside) by
651 the "SparkCut" directive
652
653 - star: Star displays now the average individual pixel-rate (IPR) versus
654 time and the average discriminator threshold (DT) of all pixels.
655
656 - optim: fixed a problem with the optim-macros which was due to a bug
657 in the new phrase parsing
658
659 - ganymed: To get a nice FalseSource plot (instead of the all-information
660 debug plot displayed as a standard plot) use the context menu
661 somewhere between the two upper plots, click on "DrawNicePlot"
662 and enjoy the result. (It is the same context menu which contains
663 the other options)
664 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
665
666 - ganymed/optim/train: The cut program, trainings- and optimization
667 macros could run with less files found than expected from the
668 sequence-files. No the execution is stopped in this case.
669
670 - ganymed: now stores the dataset in the output file with all information
671 contained (as sequence number, sequence path, data path) so that the
672 used dataset file can be recreated complete from the output
673
674 - sponde: now also allows the uasge of random forest
675
676 - sponde: added a plot showing the cut efficiency
677
678 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
679 errors (eg. effecting the collection area) because the errors of the
680 two histograms were swapped in the calculation, which makes a difference
681 in the case the histograms contains weighted events. Aditionally the
682 totalarea was incorrectly taken into account, which results in too small
683 errors, which makes a difference at low statistics were the errors
684 or the collection area dominate.
685
686
687
688 *** Version 0.10.3 (2006/10/23)
689
690 - database: Implemented ObservationMode flag in websites.
691
692 - database: For sequences there is now also the stoptime available on the
693 websites.
694
695 - database: Removed ManuallyChanged flag from sequence-info websites,
696 as it is not needed anymore with the new sequence building algorithm.
697
698 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
699 Class for calculation of confidence intervals (upper limits).
700 Use model 3 or 4 for upper limit calculation for MAGIC observations.
701 Please read the class instruction of TRolke for more information.
702
703 - general: The programs now return 0xfe if the requested resource file
704 doesn't exist.
705
706 - general: Errors comming from root itself are now not output to
707 stderr anymore but to our default (colored) log-stream.
708
709 - general: Changed the interface to TFormula such that now everything
710 is parsed by TFormula, which should allow to use phrases even
711 without paranthesis correctly parsed.
712
713 - callisto: replaced the AdHoc number of effective integration slices
714 in the digital filter by an average of the correct number, averaged
715 over all possible set of weights. This also gives correct numbers
716 for the lo-gains which were totally wrong before.
717
718 - callisto: drastically reduced memory consumption by not storing
719 all intermediate calibration results in memory anymore (we might
720 write them into a file in the future)
721
722 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
723 debug plot displayed as a standard plot) use the context menu
724 somewhere between the two upper plots, click on "DrawNicePlot"
725 and enjoy the result. (It is the same context menu which contains
726 the "DrawAll" option)
727 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
728
729
730
731 *** Version 0.10.2 (2006/10/15)
732
733 - general: changed the building of the sequence files such, that
734 the source-/project name in case of wobble-sources is not the
735 source/project of the first data run anymore but the new generalized
736 wobble source/project
737
738 - general: Added some functions to MAstro to calculate sun and
739 moon properties
740
741 - general: Added two new macros (starvisday.C and starvisyear.C)
742 which allow to plot the visibility of several stars in one day
743 or of one star along one year
744
745
746
747 *** Version 0.10.1 (2006/10/11)
748
749 - general: HTML logging output was distorted... fixed.
750
751 - general: Changed the writing of the sequencefiles such that only
752 as many pedestal files as giving at least 1000 pedestal events which
753 are nearby the first calibration run are used as pedestal runs
754
755 - sponde: In the calculation of the collection area(s) and the
756 distribution for MOnte Carlo and estimated energy the error
757 calculation was wrong because root didn't take the errors
758 properly into account... fixed.
759
760
761
762 *** Version 0.10 (2006/10/10)
763
764 - general: all executables now check consistency of the root version
765 installed with the root version used for compilation. The return
766 code in this case is 255.
767
768 - general: The algorithm to build seqeunces has been redesigned
769 completly. It is now more flexible in terms of a resource file
770 resources/sequences.rc which can be used to partly overwrite
771 the default algorithm and defined the important part of the
772 algorithm. It also takes correctly into account several ways
773 of taking wobble-data. Currently the new algorithm doesn't take
774 the number of pedestal events anymore into account (so a sequence
775 could have much less than 1000 pedestal events and data runs are
776 no-more used instead)
777
778 - general: a lot of small changes to make the code compatible with
779 root 5.12/00 and gcc 4.1
780
781 - general: Fixed some warnings thrown if more warnings are switched
782 on in the compiler
783
784 - general: Added a function to MMath which returns the Median of
785 the distribution abs(y[i]-median) but at 68:32 division instead
786 of 50:50, which is somehow the median counterpart of the rms.
787
788 - general: MAstroCatalog allows now to read calatog files (as bsc5)
789 even if they are compressed with gzip (recommended compression
790 is with "-1")
791
792 - showplot:
793 + batch mode creation of image files now works with root 5.12/00
794 + added support for writing bmp (though it never produces
795 bmp which can be read by programs like xv or gimp)
796 + added support for xml
797 + added new option to start the display with a different size, by
798 --display-width=nnn or --display-height=nnn
799 + added options to define the canvas size when the display is started
800 --canvas-width=nnn or --canvas-height=nnn
801 the option can also be used for batch-mode conversion
802 + added an option which automatically fits the display size to the
803 desktop-size: --auto-size
804
805 - merpp: didn't recognize files with the extension .raw.gz - fixed.
806
807 - merpp: allow the reports to have 1000ms due to a bug in the camera
808 program.
809
810 - callisto: New swapped pixels have been found and corrected. For
811 details see MRawRunHeader::FixAssignment()
812
813 - callisto: Callisto now raises an error if one of the input files could
814 not be opened.
815
816 - callisto: In some rare cases it could happen that in the signal
817 extraction of the digital filter the extractor returned nonsense
818 results due a wrong initializion of a variable (this happens in
819 cases in which the extracted signal is exactly zero or the
820 digital filter couldn't slide because of a too small extraction
821 window, which could happen in the lo-gain extraction)
822
823 - callisto: The lo-gains have been marked as valid in some cases
824 when they got not extracted at all (deltsumlo=deltatimelo=0) because
825 the allowed extraction range (fLoGainLast-fLoGainFirst) was
826 smaller than the number of slices (fLoGainWindowSize) needed
827 by the lo-gain extractor
828
829 - callisto: Updated absolute calibration constants (muon calibration)
830
831 - callisto: fixed a bug which caused the hi-gain saturation not
832 to be handled properly in the spline (the position of the
833 saturation was calculated incorrectly)
834
835 - callisto: fixed a bug which gave weird results if hi- _and_
836 lo-gain could not be extracted properly. In some cases hi-
837 and lo-gain have not been extracted at all and the random result
838 got calibrated. In other cases the hi-gain was saturating and the
839 lo-gain has not been extracted. For this a completly arbitraty
840 scale factor was applied to the result from extracting the
841 charge of the saturating hi-gain.
842
843 - callisto: improves handling of extracted signal if lo- and/or
844 hi-gain could not be extracted properly. If no appropriate
845 calibration of either the signal or the arrival time is possible
846 the pixel is now markes as unsuitable instead of estimated.
847
848 - callisto: Fixed a problem in the spline extraction which gave
849 weird results if the signal was extracted from the first (and
850 highest) slice (as a workaround extraction from the first
851 slice has been forbidden)
852
853 - callisto: Fixed a bug regarding the use of the QE which doesn't
854 effect the result because the default is used anyhow.
855 (The bug was there since 14/07/2005)
856
857 - callisto: Changed the default for fgLoGainStartShift to -2.4
858
859 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
860 factors to be always 10 for all pixels as soon as the first
861 calibration update has happend.
862
863 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
864 was off by more than one slice (which gives wrong values for
865 pixels which have saturated the hi-gain) This was a problem
866 mainly for timing studies, not so much for the automatic standard
867 analysis. Also the values for the Spline have been changed slightly:
868 + Digital Filter from 1.70 to 0.95
869 + Spline from 1.39 to 1.30
870 The numbers were sorted out by an extensive test in the
871 test-database.
872
873 - callisto: Removed the tab showing the average calibrated arrival
874 time. It never gave useful information.
875
876 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
877 lo-gain pulse for data pulses if hi- and lo-gain have saturated
878 and both were extracted because the hi-gain was above the
879 LoGainSwitch.
880
881 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
882 lo-gain pulse position (after application of LoGainOffset, which
883 means in the ideal case it is 0) for data pulses if hi- and lo-gain
884 have saturated and both were extracted because the hi-gain was above
885 the LoGainSwitch.
886
887 - callisto: After extensive tests a new threshold level for determination
888 of the pulse position has been found at 50phe. This is due to the
889 fact that for lower pulses the arrival time changes its average
890 behaviour dramatically. It tends to the average of the extraction
891 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
892
893 - callisto: Added two more plots to the calibration part. The average
894 extracted signal and the average extracted arrival time as
895 extracted by the signal extractor (This can help debugging problems
896 because it doesn't involve a fit)
897
898 - star: changed the fit for the effective on time such that initial
899 values are calculated automatically now instead of using build
900 in values. This makes the fit more indepedant of the underlaying
901 rates. With a test of ~350 sequences in the test database it could
902 be shown that the new fit gives the same result +/-1sek.
903 The highest deviation was +5s the lowest -10s. You can now control
904 the bahaviour with two resource values:
905 MHEffectiveOnTime.FistBin: 3
906 MHEffectiveOnTime.NumEvents: 12000
907 Use FirstBin=1 and NumEvents=120 to fit the effective on time
908 from the resulting gamma candidates
909
910 - star: The Center histogram in MHHillas is now by default displayed
911 with the colz draw-option
912
913 - ganymed: now produces valid error codes if failed
914
915 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
916 with the option "hadronness" instead of "area" or "both" if
917 you want to use both cuts. The hadronness cut includes a fixed
918 cut in hadronness (index 8) and a fixed cut in size (index 9).
919
920 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
921 the M3Long of the anti source to be not properly evaluated
922 (actually is was evaluated as a unique random number) in case
923 of optimization with anti-theta cut switched on. This might have
924 lead to improper, but not necessarily wrong, optimization results.
925
926 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
927 how to use random forest
928
929 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
930 ganymed_onoff.rc. Seems to be unintentional that they were different.
931
932 - sponde: Since the introduction of the possibility to define a
933 normalization energy instead of using the integral the default
934 was not using the integral anymore but a normalization energy of
935 1GeV. It is now the integral again.
936
937 - sponde: Fixed a problem in the weighting which did not allow
938 a MC slope of -1.
939
940
941
942 *** Version 0.9.6 (2006/05/24)
943
944 - general: changed the binning of the azimuthal profile of the camera
945 such that it is aligned with the 60deg boundaries.
946
947 - merpp: better handling of problems with the TH, TD part of the
948 CC-REPORT for files older than 200507190 and 200412210
949 respectively
950
951 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
952
953 - merpp: implementd latest changes in starguider reports (sinc 9th May)
954
955 - callisto: if an arrival time is extracted outside the fadc range is
956 was set to the boundary before. Now a random number is assigned
957 instead to avoid unfortunate coincidences of arrival times just
958 by this arbitrary value.
959
960 - callisto: added a new option to callisto.rc which allows
961 to set the maximum arrival time difference allowed for the
962 badpixel algorithm to determin whether a pixels belongs to a shower:
963 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
964
965 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
966 to 0.9 as suggested by Stefan due to a recent study on the fraction
967 of pixels surviving the image cleaning
968
969 - callisto: switched off error in case of "pulse is too much to the left"
970
971 - callisto: The extraction window is not adapted anymore. This means that
972 the pulse is extracted from the full range. The draw-back is that the
973 background (pedestal) will become slightly higher. Switching on/off
974 the PulsePosCheck in the callisto.rc only effects filling the
975 histograms.
976 WARNING: If the pulse is too much to the left data is calibrated!
977 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
978 in the database to make sure that your data is valid!
979
980 - star: Show also the number of stars correlated correctly by the
981 starguider
982
983 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
984 than one off-source region in wobble-mode. To use it add the following to
985 your ganymed_wobble.rc:
986 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
987 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
988 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
989 + Cut1.ThetaCut: None
990 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
991
992 - ganymed: in the case the latest report is older than a default (currently
993 one minute) and the current report will be skip the starguider
994 correction and calibration will be reset. The maximum age can be
995 setup from ganymed.rc by (minutes):
996 MPointingDevCalc.MaxAge: 1.5
997
998 - ganymed: A first implementation showing all size-bins for the theta-sq
999 resp. alpha-plots in a single tab automatically
1000
1001
1002
1003 *** Version 0.9.5.1 (2006/05/05)
1004
1005 - general: Added a new option "zdiff" to the Makefile which runs
1006 "cvs diff" as "make diff" would do, but with compression
1007
1008 - general: accelerated MTFillMatrix (used for eample in all training
1009 and optimization macros) by skipping some obsolete calles in the
1010 eventloop the first and second loop could be accelerated by ~20%
1011
1012 - general: Added a missing feature in the MFilterList class which
1013 prevented MFEnergySlope from working correctly in trainenergy.C
1014
1015 - general: Accelerated the random forest training and usage a bit
1016
1017 - merpp: Adapted to new raw data file format version 6
1018
1019 - merpp: fixed a problem with reading the starguider reports
1020 after 6.3.2006
1021
1022 - callisto: At some times six pixels had to be exchanged manually in the
1023 data. If the pixels to be swaped are both not found, an error was raised
1024 and calibration was stopped. Now it is assumed they are intentially not
1025 mapped and the Error has been changed to a Warning.
1026
1027 - star: Added new image cleaning based on the arrival time of the shower.
1028 The new cleaning can be accessed using the parameter "Time" instead of
1029 the the old one (like "Absolute) in the star.rc-file.
1030 Recommended parameters:
1031 + MImgCleanStd.CleanLevel1: 8.2
1032 + MImgCleanStd.CleanLevel2: 5
1033 + MImgCleanStd.CleanRings: 2
1034 + MImgCleanStd.KeepSinglePixels: No
1035
1036 - star: Simplified the calculation of the effective on time. By letting
1037 the fit start in the third bin the result should become more stable.
1038 The fit quality is now ignored for the theta-plot which is not used
1039 in the analysis later. Still better pre-cut which, for example,
1040 remove events triggered by car-light (rate changing on a short
1041 time-scale) are missing.
1042
1043 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1044 for optimization (kWeakSource) which is suggested by the Berlin
1045 people for weak sources.
1046
1047 - macros: plotdb.C:
1048 + if no dataset and no time-interval is given only sequences with
1049 an effective on-time above five minutes are plotted anymore
1050 + added a new tab "RelTime" displaying the relative on-time
1051 (effective on-time divided by the observation time)
1052
1053 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1054 the optimization became a lot faster
1055
1056 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1057 To display them just delete the pads displayed on top.
1058
1059 - ganymed: fixed a bug which could cause strange behaviour in wobble
1060 mode if no starguider information was available due to an incorrect
1061 initialization of the starguider calibration
1062
1063 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1064 be changed from within the plot. It can also be setup from the
1065 resource file using:
1066 + MHDisp.fScaleMin: 0.325
1067 + MHDisp.fScaleMax: 0.475
1068
1069 - ganymed, showplot: Fixed a problem with the fit to the off-data
1070 (HistOff) which could cause a time lag or an inifinite loop.
1071 The bug did not effect the results at all.
1072
1073 - sponde: Added a new tab showing the effective collection area after
1074 trigger (including the software trigger)
1075
1076 - sponde: MMcSpectrumWeight has a new option which allows to define
1077 the scaling factor not by the integral of the events but at
1078 a defined energy:
1079 e.g. MMcSpectrumWeight.NormEnergy: 200
1080
1081 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1082 eventloops the loop could be accelerated by ~20%
1083
1084
1085
1086 *** Version 0.9.5 (2006/03/13)
1087
1088 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1089 and added the standard Disp-parametrization
1090
1091 - macros: added a new macro datacenter/macros/plotstat.C allowing
1092 to plot statistics about the data processing
1093
1094 - macros: added a new macro to plot the muon correction coefficients
1095 versus period (macros/plot/mucal.C)
1096
1097 - showplot: path inflation for ganymed files was broken
1098
1099 - callisto: Fixed an important bug. When the number of saturating pixels
1100 were calculated the bad pixel information already available from the
1101 calibration was ignored. This yields wrong values in case pixels
1102 are broken and saturate all the time or randomly.
1103
1104 - callisto: Updated Muon calibration constants. Spline data now also uses
1105 different values for different periods
1106
1107 - star: The time-evolution shown in the effective on-time plot now displays
1108 the axis range (if there are no holes it should be similar to the
1109 effective on-time)
1110
1111 - star: Added two new image parameters:
1112 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1113 the three pixels next to the center of gravity and the size
1114 + MNewImagePar.fConcCore: The ratio of the signals of all
1115 pixels inside or touching the ellipse and the size
1116
1117 - ganymed: now stops in requested source isn't found in catalog file
1118
1119 - ganymed: Many improvements to the phi-plot in wobble mode:
1120 + with a template the ideal background is displayed
1121 + a possible camera inhomogeneity is taken into account
1122 + the anti theta cut is better supported
1123 + the phi cut is automatically calculated from the theta cut
1124 See the examples in ganymed_wobble.rc for more details.
1125
1126 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1127 times the bin-width instead of the absolute energy
1128
1129 - ganymed: New cuts for on/off and wobble mode
1130
1131 - ganymed: The smearing of the False Source plot has been increased
1132 to 0.06
1133
1134 - ganymed: The starguider calibration can now be changed from the
1135 resource file.
1136 See the examples in ganymed*.rc for more details.
1137
1138 - ganymed: added a new option for on-/off-observations
1139 MJCut.RandomSourcePosition
1140 If switched on the distribution of observation time of the source
1141 position in the camera is calculated from the on-data and randomly
1142 applied with this distrbution to the off-data.
1143
1144 - ganymed: by skipping some obsolete calles in the eventloop the
1145 first and second loop could be accelerated by ~20%
1146
1147 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1148 position in the off-data randomly according to its distribution in the
1149 on-data.
1150
1151
1152
1153 *** Version 0.9.4.3 (2006/02/13)
1154
1155 - general: Fixed a bug in most of the programs which prevented the
1156 compile date in the startup message to be displayed
1157
1158 - general: Simplified program calls. The following abbreviations
1159 are now possible:
1160 showlog callisto 55599
1161 showplot signal 55599
1162 star 55599
1163 callisto 55999
1164 ganymed 2
1165 In this cases the corrsponding root-, log-, sequence- or dataset-
1166 filename is automatically compiled using the default datacenter
1167 paths ("/magic/*")
1168
1169 - general: Fixed a long outstanding bug which made axis tick marks
1170 disappear if MDataFormula was used (eg. abs(x))
1171
1172 - general: Updated MMath with new functions to calculate the results of
1173 a exponential, logarithmic and powerlaw fits analytically.
1174
1175 - general: Updated some macros with comments:
1176 + macros/optim/optimdisp.C
1177 + macros/optim/optimenergy.C
1178 + macros/optim/optimwobble.C:
1179
1180 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1181 files) now allows adding a pre-cut like in the optimization. E.g. this
1182 is useful to perform g/h-separation cuts before training the random
1183 forest.
1184
1185 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1186 correctly assigned in the raw data assignement table. A fix to correct
1187 the assignment tabel have been implemented.
1188
1189 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1190 by 90, 180 and 270 deg.
1191
1192 - general: the macro plotdb.C now allows to highlight sequences belonging
1193 to a datset. For more details see the descritions in the macro.
1194
1195 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1196 of the display, it gave wrong results espacially for big sizes.
1197 Now the embedded canvas should always have a ratio width/height=3/2.
1198 The "Size" options have been updated with values fitting the 3/2
1199 size ratio.
1200
1201 - RanForest:
1202 + Updated the random forest classes to support also the
1203 regression method implemented by Thomas H.
1204 + added new tutorial macro how to train the random forest
1205 for energy estimation (macros/optim/rfenergyest.C)
1206 + new classes to train the random forest (still in development)
1207 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1208 + new tutorial macros for random forest training in macros/train
1209 trainenergy.C, traindisp.C, trainseparation.C
1210
1211 - mars: now allows to setup a cut in the resource file mars.rc to choose
1212 the events to be displayed, eg:
1213 Cut.Condition: {0} && {1}
1214 Cut.0: MHillas.fSize>100
1215 Cut.1: MHillas.fSize<900
1216
1217 - merpp: Made aware of the new .rep format 200510250. This includes
1218 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1219 the discriminator thresholds (MCameraTD) and the disciminator
1220 delays (MCameraTD). All of them come with the CC report and are therefor
1221 written to the CC tree.
1222
1223 - callisto: fixed a bug in the calculation of the arrival times in
1224 the Digital Filter. They were all shifted by the same amount
1225 fHiGainFirst. This caused an offset in the order of the position of
1226 the left border of the extraction window in the times calculated
1227 from high-gain and from low-gain. The bug effected only the absolute
1228 arrival times. The bug was there since 30.1.2005.
1229
1230 - callisto: Changed the ExtractionWindow for the pulse position check
1231 such that the camera inhomogeneity becomes as less as possible and
1232 comparable to the pulso position check switched off. More details
1233 on the study will be given at our result web-page.
1234
1235 - ganymed: ganymed.rc, ganymed_onoff.rc:
1236 changed to new cuts trained with 1ES1218 and Crab-data
1237 for maximum sigma*log10(excess)
1238
1239 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1240 a new option was implemented to estimate Disp (CalcDisp)
1241
1242 - ganymed: Implemented two new options which allow
1243 to overwrite the default path to search for the sequence files
1244 --ins=/magic/sequences
1245 and where to search for the image data
1246 --ind=/magic/data/star
1247
1248 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1249 dx/dy from the resource file by
1250 MSrcPosCorrect.Dx
1251 MSrcPosCorrect.Dy
1252
1253 - ganymed: fixed reading the source catalog. Only as many chars
1254 as the requested source name had were compared (If a source
1255 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1256 were requested it could happen that the coordinates of
1257 "1ES1218" were read) The source coordinates are now printed
1258 in addition to its name to the logging output.
1259
1260 - ganymed: changed the background fit in the case of a ThetaSq function
1261 from a polynomial to a exponential, this should give a big improvement
1262 for on-only analysis'
1263
1264 - ganymed/sponde: Calculation of the error of single size-/energy-
1265 bins now uses Li/Ma (5) instead of LiMa (17)
1266
1267 - sponde: Added a plot E^2*dN/dE
1268
1269 - sponde: The energy estimator plot should now show values like
1270 they are commonly used.
1271
1272 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1273 (a powerlaw with cutoff didn't work before)
1274
1275
1276
1277 *** Version 0.9.4.2 (2005/10/01)
1278
1279 - general: added new tutorial macro macros/tutorials/threshold.C:
1280 how to calculate the threshold
1281
1282 - general: added a new game. Start it from the interpreter with
1283 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1284 and MagicReversi)
1285
1286 - general: neighbor pixels in MGeoms are now sorted clockwise
1287
1288 - merpp: made aware of new format 20050829-0
1289
1290 - callisto: New scale factors from muon analysis, stored in new
1291 resource file resources/calibration.rc
1292
1293 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1294 the eventloop if something went wrong. This is necessary for the
1295 automatic processing
1296
1297 - callisto: Implemented a new treatment for the time information
1298 developed by S.Ruegamer, this should give much better response than
1299 the old very primitive algorithm. This is especially important
1300 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1301 treatment was buggy! As neighbor pixels to interpolate the
1302 arrival times always the pixels 0 to 5 were taken)
1303
1304 - callisto: In addition to the new treatment of arrival times the
1305 decision of the treatment whether a pixel contains shower
1306 information or not is used to improve the signal interpolation
1307 further. Previously interpolated pixels showed a non-zero signal
1308 do the peak searching signal extractors. Having a signal pixel
1309 beside raised the signal above the cleaning level. Thus the
1310 pixel survived cleaning to often but with a too low mean signal.
1311 By replacing empty pixels with a gaus (mean and rms from the
1312 corresponding Area entries in MPedPhotCam) this effect can
1313 be supressed.
1314
1315 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1316 got lost when the events were stored by the calibration... fixed.
1317 (This was no problem for normal image cleaning because the pixel
1318 content was artificially set to 0 not surviving standard cleaning
1319 algorithm)
1320
1321 - callisto: Fixed a bug which caused the random and peak-search pedestal
1322 extracted with an extractor to be exchanged for the first (roughly)
1323 500 events (*Extractor and *ExtractorRndm).
1324 (They were simply exchanged in callisto.cc) This bug might have been
1325 introduced in Mars 0.9.4 when the order of calculation of the two
1326 types of pedestal in callisto got exchanged. The bug only effects
1327 the first seconds of data of each sequence.
1328
1329 - star: Taking the arrival time of Muons into account the calculation
1330 of the parameters could be made independant of the noise
1331 (pedestal rms). The dependance was due to the bias of the peak search
1332 extractor. Now only a ZA dependamcy is left which is not yet fully
1333 understood.
1334
1335 - ganymed: The sequences were still not sorted correctly in any case,
1336 because they were sorted by the full qualified path name. Now they
1337 are sorted by their sequence number.
1338
1339 - ganymed: new values for the spark-event-cut
1340
1341 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1342
1343
1344
1345 *** Version 0.9.4.1 (2005/08/18)
1346
1347 - callisto: fixed some problems with the calibration in case of
1348 inteleaved events. Therefor the final and some intermediate
1349 fits are skipped which would take place on partly filled #
1350 histograms and gave wrong results or failed completely.
1351
1352 - callisto: If the intermediate finalization of the histograms
1353 calculating the mean charge of the calibration signal fails
1354 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1355
1356 - ganymed: Fixed some bugs which caused problems in On-only mode.
1357 Still the false source plot doesn't give reasonable results.
1358
1359
1360
1361 *** Version 0.9.4 (2005/08/05)
1362
1363 - general: Fixed the ZA binning. It did not correctly fit the
1364 MC binning
1365
1366 - general: Added a class to correct for the missfocussing in
1367 April (MSrcPosCorrect)
1368
1369 - general: Random Forest energy estimator should now work properly
1370
1371 - general: MHCamera now displays the profiles in deg instead of mm
1372
1373 - general: MH::SetPalette offers a lot of new palettes
1374
1375 - general: MHillas - the case of CorrXY==0 is now handled properly
1376
1377 - general: implemented the possibility to change the line and
1378 marker style of a sky-grid drawn by MAstroCatalog
1379
1380 - general: Runs in sequences and datasets are now automatically
1381 ordered (it is assumed that the order of their filenames correctly
1382 represents the order of observations) to ensure correct reading
1383 of the subsystem data
1384
1385 - general: Runs cannot be added to a sequence twice anymore. Also
1386 Sequences cannot be added twice anymore to a dataset.
1387
1388 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1389 It gave wrong results by 1./2pi
1390
1391 - showplot: got a new option to start a root interpreter, too
1392
1393 - mars: now displays a rough estimate of Disp and the third moment
1394
1395 - mars: now displays the event time MTime if available
1396
1397 - mars: show muon parameters graphically
1398
1399 - mars: now the file to open can be given as commandline
1400 argument
1401
1402 - merpp: Added support for new arehucas version >= 200507190
1403 implementing values for three temperature sensors in the
1404 counting house (MCameraAUX) and the name of the HV settings file
1405 (MCameraHV).
1406
1407 - merrp: Also fixed some problems with wrong versions numbers stated
1408 by arehucas and implemented some fixed for old versions (<200407070)
1409
1410 - callisto: MCalibrationHiLoCam can now be printed from its context
1411 menu, eg in the TBrowser
1412
1413 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1414 - 1.39 (MExtractTimeAndChargeSpline)
1415 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1416 This is important mainly for timing studies.
1417
1418 - callisto: Changed limits in MHCalibrationChargeCalc from
1419 - -100.125 to -98 (fgChargeHiGainFirst)
1420 - 1899.875 to 1902. (fgChargeHiGainLast)
1421 - -100.25 to -99 (fgChargeLoGainFirst)
1422 - 899.75 to 901. (fgChargeLoGainLast)
1423 Introduced new limits:
1424 - fgNumLoGainBlackoutLimit: 0.05
1425 - fgLoGainBlackoutLimit: 3.5
1426 - fgLoGainPickupLimit: 3.5
1427
1428 - callisto: The handling of automatic weights for the digital filter
1429 has been improved. There are now new calibration weights special
1430 for Monte Carlo calibrations.
1431
1432 - callisto: Updated Muon scale with latest results (1% difference
1433 for most data, 5% for Mar/Apr'05)
1434
1435 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1436 was saturated and the blackout-events in the low-gain exceed the
1437 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1438 This excludes those pixels which have a saturating high-gain
1439 channel, but the low-gain switch does not switch often enough
1440 to make the distribution reliable.
1441
1442 - callisto: fix a bug counting the number of saturated events. Up to now,
1443 the number of saturated slices was counted (which is one for a not too
1444 high number), but for some (pathological) pixels, many more slices
1445 saturated and produced wrong limits.
1446
1447 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1448 + MCalibrationRelTimeCam.CheckFitResults: Yes
1449 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1450 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1451 + MCalibrationRelTimeCam.CheckOscillations: Yes
1452
1453 - callisto: introduce max. number of events for intercalibration,
1454 the rest gets skipped. Default: 4096
1455 The calibration causes too many un-reliable pixels if more
1456 than about 5000 events are treated (@500 Hz) because of the
1457 mode hopping of the VCSels. However, in the past, some
1458 calibration runs have been taken (erroneously) with more
1459 than 5000 events, especially the intensity scans where
1460 a good precision is needed.
1461
1462 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1463 photo-electrons for the spline extractor by 1-2% (correctly).
1464
1465 - callisto: The intercalibration is now done using a full f-factor
1466 method instead of a simple update. This makes things slower but
1467 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1468 changes.
1469
1470 - callisto: MPedestalY3 now uses the same extraction range as the data
1471 as calculated by MPedestalY2
1472
1473 - callisto: A check of the fraction of allowed unsuitable (10%) and
1474 unreliable (30%) pixels has been addded when the conversion is
1475 calculated from interleaved events
1476
1477 - star: fixed a bug which caused MEffectiveOnTime containers not to
1478 be written. In the worst case they were skipped almost all, in the
1479 best case they were all ok. It depends on how often the new value
1480 was assigned just with an event which was skipped later by another
1481 task
1482
1483 - star: new histograms MHPointing and MHRate
1484
1485 - star: New tab (Currents) displaying the time evolution of the mean
1486 DC currents
1487
1488 - star: New tab (MeanRms) displaying the time volution of the mean
1489 Pedestal Rms
1490
1491 - star: Output now contains MReportStarguider
1492
1493 - star: Improved muon analysis. Due to the absense of a constant
1494 for the gaus fit for arc width and the fact that the arcwidth
1495 plot was a histogram instead of a profile the resulting psf
1496 became pedestal rms dependant
1497
1498 - ganymed: added new plot (MHPhi) for wobble mode as described in
1499 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1500
1501 - ganymed: corrects now (correctly?) for the misspointing in
1502 May/April 05
1503
1504 - ganymed: Two new default templates for ganymed.rc are avilable:
1505 ganymed_onoff.rc and ganymed_wobble.rc
1506
1507 - ganymed: The first version of MFMagicCuts has been released
1508
1509 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1510
1511 - ganymed, sponde: There are two new options to determin the number
1512 of bins for the signal region (NumBinsSignal) and the number of
1513 total bins (NumBinsTotal) in the MHThetaSq histogram
1514
1515 - ganymed: optimized palettes for MHDisp
1516
1517 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1518 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1519 sqrt(2) to large
1520
1521 - ganymed: The false source plot (MHDisp) is now based on Disp
1522 and a background model determined in the first loop is
1523 subtracted
1524
1525 - ganymed: MFMagicCuts are now available in the cvs. The correct
1526 solution for the disp ambiguity problem is now calculated using
1527 the third moment. The third moment cut therefor is skipped.
1528
1529 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1530 already determined by the third moment along the major axis and
1531 so its actual sign is aligned along the major axis of the shower.
1532
1533 - ganymed: If starguider data is available it is taken into account
1534 when calculating the source position. This is especially important
1535 for wobble data at high zenith angles and culmination data.
1536
1537 - ganymed: If available the starguider data is taken into account as
1538 good as it is possible without a starguider calibration. To switch
1539 it off add
1540 MPointingDevCalc.MaxAbsDev: -1
1541 to your ganymed.rc
1542
1543 - sponde: the zenith angle distribution is now weighted instead of
1544 choosen by default. This gurantees higher statistics in the highest
1545 and lowest energy bins. To switch this behaviour off use...
1546
1547 - sponde: now automatically displays the energy threshold
1548
1549
1550
1551 *** Version 0.9.3 (2005/06/03)
1552
1553 - general: MMcEvt now derived from MMcEvtBasic which should
1554 have no influence on compatibility with older camera files
1555
1556 - general: Implemented a new option to MReadReports which allows
1557 to force reading of the first event of some trees (eg. Drive-tree)
1558 before any other tree.
1559
1560 - general: Made a fix to MPointingPosCalc which assumes that the
1561 run-type is real-data if Process is called before ReInit, such
1562 that also the very first Drive-events in a run are treated
1563 correctly.
1564
1565 - shoplot now displays the filename in the title bar of the window
1566
1567 - merpp: new options: --auto-time-start --auto-time-stop which
1568 allow to cut updating with slow-control at the start- or
1569 (previousle --auto-time only allowed: and) stop-time of
1570 the run stored in the runheader.
1571
1572 - callisto: changed default of fgFallTimeHiGain in
1573 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1574 already set as default in callisto_Dec04Jan05.rc
1575
1576 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1577 now changes the filename for new weights automatically for
1578 cosmics, MC and for different calibration colors.
1579
1580 - callisto: a problem with the order of some code cause the
1581 name of the weights file in MPedestalY2 to be ignored.
1582 Wrongly the calibration_UV weights were used instead
1583 of the cosmics weights set in callisto.rc.
1584
1585 - callisto: should allow ct1 pulser data when the color is
1586 explicitly set also for pretty new runs
1587
1588 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1589 to introduce an additional scale factor (should be around 1)
1590 to adapt for slight deviations in different extractors from
1591 the MC calibration. For MC calibrations the scale factor
1592 is fixed to 1
1593
1594 - callisto: MFCosmics should handle very high signals a bit
1595 more accurate now
1596
1597 - callisto: when calculating the mean pedestal rms for different
1598 pixel sizes or sectors also kUnsuitableEvt is now taken into
1599 account - not only kUnsuitableRun
1600
1601 - callisto: '-raw' option is now the default
1602
1603 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1604 This has the advantage that mean values in the calibration (eg
1605 arrival times) are calculated more accuratly.
1606
1607 - callisto: In the resource file callisto_Dec04Jan05.rc
1608 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1609
1610 - callisto: new Hi-/Lo-Gain intercalibration constants
1611 hilocalib_sp1.root and hilocalib_sp1_mc.root
1612
1613 - callisto: changed default for MJPedestalY2.MaxEvents
1614 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1615
1616 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1617 has changed from 9.0 to 6.0. This is necessary to exclude two very
1618 ringing pixels in September which - when kept - destroy the image
1619 cleaning around them (Markus G.)
1620
1621 - callisto: (!) The Muon analysis of all data taken so far has
1622 suggested that different extractors give slightly different
1623 absolute results after calibration, due to there different
1624 handling of the calibration- and cosmics pulse shape. Although
1625 the over all calibration seems to be a bit to pesimistic (or
1626 the MC seems to be a little bit - 3-5% - too much attenuated).
1627 There for correction factors have been introduced which correct
1628 the calibration constants by
1629 0.956937799 for Digital Filter (callisto.rc)
1630 and
1631 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1632 calibration. The main advantage is, that both data types can
1633 be easily analysed together and compared to the same MC sample.
1634 The factors are choosen such, that the reference is now a
1635 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1636
1637 - star: fixed a bug which caused the first bin of the histograms
1638 vs time to disapear in PostProcess. This gave wrong results
1639 on the screen. The output and all following programs not
1640 directly accessing the histograms haven't been affected
1641
1642 - star, ganymed: Made sure that always the first Drive-tree event
1643 is read and Processed before the first data event was read.
1644
1645 - ganymed: implemented the possibility to replace the standard
1646 false source plot with a different one. For example: If
1647 you want to use a Disp based FS plot use the resource:
1648 NameHistFS: MHDisp
1649 For details about the requirements of these plots look
1650 at the corresponding classes
1651
1652 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1653 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1654 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1655 case MAlphaFitter is setup correctly. For On-Only optimization
1656 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1657 RunOn() instead of Run(). For energy estimation MJOptimize
1658 has been replaced by MJOptimizeEnergy
1659
1660 - sponde: The input MC spectrum can now be weighted to fake a
1661 different spectrum. This is done via MMcSpectrumWeight. For
1662 more details see the class description and sponde.rc
1663
1664 - sponde: The paremeter comparsion plots are not scaled by
1665 their entries anymore. Instead the MC plot is scaled by using
1666 the result spectrum of the analysis. If the input MC spectrum
1667 and the result spectrum has different slopes the absolut
1668 normalization is normally wrong.
1669
1670
1671
1672 *** Version 0.9.2 (2005/05/20)
1673
1674 - general: Changed the default paths for calibrated data and image
1675 files. (The implemented access to these files doesn't yet exist)
1676
1677 - general: support for MRunIter has been removed from the job classes
1678 (use the setter functions of MSeqeunce instead)
1679
1680 - general: ProcessFile has been renamed to Process in all job classes,
1681 because ProcessFile is missleading
1682
1683 - general: The storage of the palette in MHCamera is now possible
1684
1685 - general: new bits describing unsuitable and unreliable pixels have
1686 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1687 kDeadPedestalRms, kFluctuatingArrivalTimes
1688
1689 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1690 versions newer than V200404070
1691
1692 - general: support for cc file versions newer than V200504130. Added
1693 support for active loads (MCameraActiveLoad) and central pixel
1694 (MCameraCentralPixel)
1695
1696 - general: added new histograms for image parameters versus size
1697 (MHVsSize)
1698
1699 - general: The eventloop now automatically calls PrintStatistics
1700
1701 - Status Display: Improved support for printing:
1702 + A default can now be set in .rootrc (for more details see
1703 MStatusDisplay::PrintPS)
1704 + A print dialog is opened so that printer and command line
1705 can be canged
1706
1707 - showlog: improved such that it handles different verbosity levels
1708 more accurate now. This mean you can suppress output when
1709 using showlog.
1710
1711 - showplot: improved
1712 + The new graphics formats have been implemented
1713 (pdf, svg, png, jpg and xpm)
1714 + Implemented an interface for printing. Because you can change
1715 the printing command from the command line you can use all
1716 the nice postscript tool. To print a booklet for example call:
1717 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1718 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1719 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1720
1721 - callisto: fixed a bug in the recognition of the calibration bit
1722 pattern. Concerns only intensity calibration. (The strength of the
1723 intensity has been updated in some cases)
1724
1725 - callisto: add a filter against PIN Diode events when running over
1726 calibration runs since some of the recent calibration runs have
1727 been taken with Pin Diode.
1728
1729 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1730 39943, 44833 in the calibration (MCalibColorSet)
1731
1732 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1733 been set to 1e-18 in callisto_Dec04_Jan05.rc
1734
1735 - callisto: in callisto_Dec04Jan05.rc: set value for
1736 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1737 statistics for the calculation of the mean pulse time
1738 of the cosmisc
1739
1740 - callisto: the charge limit in the calibration has been raised
1741 from 2.5 to 4.5
1742
1743 - callisto: new setup read from callisto.rc
1744 + MCalibCalcFromPast.fNumEventsDump
1745 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1746 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1747
1748 - callisto: MExtractTimeAndChargeSpline extractor:
1749 + The integration ranges were shifted by 0.2 FADC slices to the right.
1750 + unreliable handling of floating point values caused different
1751 results on different platform or with different compiler options:
1752 The new algorithm is numerically exact and more accurate because
1753 it doesn't calculate the integration position by multiple times
1754 adding the step-size (which results in numerical uncertanties
1755 exspecially if multiplied with large numbers)
1756 + A lot of fixes have been introduced which effects integrating the
1757 spline at the edges of the valid range. In this case any memory
1758 was randomly accessed. This behaviour can be tested replacing
1759 all MArrayF by TArrayF which perform a range check (but of course
1760 they are a lot slower)
1761 ! No result obtained with the Spline before can be trusted! Due to
1762 random memory access it might by completely random!
1763
1764 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1765 + extraction range in the high gain to 4.
1766 + weights file to cosmics_weights46.dat
1767
1768 - callisto:
1769 + introduce the check for fluctuating arrival times.
1770 + set charge limit to from 2.5 to 4.5
1771 + introduce asymmetric exclusion due to "deviating number of phes":
1772 Default: -9.0 +4.5
1773 + make deviating number of phes unsuitable (see David's findings).
1774
1775 - callisto: fixed the display of unsuitable pixels. The old change
1776 to a real profile in MHCamera broke it.
1777
1778 - callisto: The cosmics filter is used in MJCalibration now
1779 independant of the pulser color (formaly it was used only for
1780 CT1-pulser data). The threshold of number of max empty pixels
1781 has been raised from 2% to 5% in MJCalibration. The maximum
1782 fraction of rejected event is 50% otherwise the calibration has
1783 failed. The filter now ignores unsuitable pixels.
1784 Setup the filter from callisto.rc using "ContCosmics"
1785 (see MFCosmics::ReadEnv)
1786
1787 - callisto: changed default for fgOffsetFromLogain back
1788 from -2.8 to -1.8 in digital filter.
1789
1790 - callisto: for the common extractors
1791 + MExtractFixedWindow
1792 * MExtractTimeAndChargeSlidingWindow
1793 * MExtractTimeAndChargeSpline
1794 * MExtractTimeAndChargeDigitalFilter
1795 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1796 and fResolutionPerPheLoGain
1797
1798 - callisto: Updated the hi-/lo-gain intercalibration constants
1799 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1800 hilocalib_df6.root
1801
1802 - callisto: The default lo-gain extraction window for the
1803 MExtractTimeAndChargeSlidingWindow extractor has been increased
1804 from 6 to 8 to take the stretch of the pusle into account
1805
1806 - callisto (!!!): fixed an important bug in the setting of the
1807 incoming pedestal pointer to the signal extractor extracting
1808 pedestals. This bug caused the pedestals not to be subtracted
1809 correctly in the calibration afterwards. The effect was about 10%
1810 too high conversion factors for the digital filter and the spline
1811 and more than 40% for the sliding window.
1812 The bug existed since end of February! (Markus G.)
1813
1814 - star: added muon support to star. A new tab "MHMuonPar" is
1815 displayed. The lower right plot is an estimate of the point spread
1816 function. A reference value is displayed. To get the real PSF
1817 you must compare with MC. The setup for the muon analysis
1818 is done in star.rc. More informations can be found in
1819 MHSingleMuon and MHCalibParCalc
1820
1821 - star: The weather data is now displayed in star
1822
1823 - star: MEventRateCalc handles the calculation of the event rate more
1824 accurate now in case of the start of a new run inside a sequence
1825
1826 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1827 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1828 changed only minimally
1829
1830 - ganymed: (MJCut and MJOptimize) now displayes the number of
1831 excess events versus size. The energy estimation is done in
1832 MJSpectrum (sponde)
1833
1834 - ganymed: got support for using other variables than Alpha, eg. Theta.
1835 Therefor you need a class deriving from MHAlpha which supports
1836 this variable (one is already existing: MHTheta, which is now the
1837 default in ganymed). It is setup through ganymed.rc
1838
1839 - added a full featured spectrum program (sponde) which reads
1840 ganymed output and monte carlos and compiles a spectrum
1841
1842
1843
1844 *** Version 0.9.1 (2005/04/14)
1845
1846 - Fix bug on the arrival time reconstruction when using Digital
1847 Filter (in some marginal cases (10%) times were reconstructed shifted
1848 by 0.2 slices)
1849
1850 - all executables now return 2 where in previous versions -1 has
1851 been returned (gave problems with shell-scripts)
1852
1853 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1854 also done with a intercalibration input file
1855
1856 - a bug in the time fine adjustment of the digital filter has been fixed
1857
1858 - a lot of small fixes to calling TPad::Divide with a margin==0
1859
1860 - MStatusDisplay now shows the memory usage
1861
1862 - added a memory leak statistic after the eventloop
1863
1864 - MHadronness replaced by MParameterD
1865
1866 - MEnergyEst replaced by MParameterD
1867
1868 - wobble mode can now be switched on from the data-set
1869
1870 - switched on bad pixel detection for a pedestal level
1871 which is more than 5 times the variance
1872
1873 - Fixed default paths to be correct for the new data center
1874
1875 - Fixed handling of drive data. The pointing position in now
1876 copied to MPointingPos inside star for real and MC events
1877
1878 - made sure, that the sequences in a dataset are sorted by
1879 their number to ensure the correct synchronization
1880
1881 - added all resource files necessary to handle spline extraction
1882 of signal for the late 2004 and the early 2005 data
1883
1884 - update the reference lines for the december data
1885
1886 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1887 This is important for the Dec. and Jan. data where the calibration
1888 pulse position changes much.
1889
1890 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1891 filter. This corrects only an defective extraction of the MC at
1892 low-gain signals lower than 90 phes.
1893
1894 - fixed some slowdown in calibrating data with interleaved events from
1895 Jan and Dec. As a workaround made the pretty palette the default.
1896 The inverse Deep Blue Sea has a bug which slows down long calibration
1897 runs a lot.
1898
1899 - implemented new values from new starguider report as defined
1900 in TDAS00-07 V7.1 (eg SkyBrighness)
1901
1902 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1903 in starguider report (If you merpp the same reports with this version
1904 you'll get the correct units (arcmin) but a different result
1905 than with old versions (wrong units))
1906
1907 - Now the status display can also write PNG, JPEG and XPM (other file
1908 formats are still unsupported by root)
1909
1910 - added a lot of scripts and macros in directory datacenter used
1911 for automatic processing
1912
1913
1914
1915 *** Version 0.9 (2005/03/23)
1916
1917 - Calibration is now done autmatically into photo-electrons like
1918 decided by the Collaboration Board
1919
1920 - Reference lines in the display can be read from resource file
1921
1922 - Interlaced calibration events can be handled by callisto
1923
1924 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1925 and applied in callisto.
1926
1927 - class MJCalibTest can be called by callisto
1928
1929 - callisto can now run with three data types: rawdata, rootdata, MC
1930
1931 - added two classes mreport/MReportStarguider.cc and
1932 mreport/MReportStarguider.h for implementing starguider-data
1933
1934 - the output of merpp-update now contains starguider information:
1935 MReportStarguider and MTimeStarguider
1936
1937 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1938 values were lower than they should. This was more visible for high
1939 energy (Size) events.
1940
1941 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1942
1943 - added a new loop to callisto to support the correct extraction of
1944 the pedestal and pedestal rms through the signal extractor
1945
1946 - added class to perform fourier tranformation of a hexagonal structure
1947 (MHexagonalFT)
1948
1949 - added class to perform fourier tranformation of a hexagonal structure
1950 in a tasklist (MHexagonalFTCalc) example: hft.C
1951
1952 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1953 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1954 small pixels, example: extendcam.C
1955
1956 - added possibility to write data to memory (TTree) using MWriteRootFile
1957
1958 - added possibility to read a TTree stored only in memory by MReadTree
1959
1960 - new classes to deal with the interleaved calibration events:
1961 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1962
1963 - implemented filters to callisto to skip calibration events
1964
1965 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1966 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1967 the slices by statistics
1968 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1969 signal extractor without randomization
1970 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1971 with the signal extractor with randomization (extraction window is
1972 randomly fixed)
1973 The three kind of pedestal is not yet implemented (for speed reasons) as
1974 long as nobody really needs it:
1975 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1976 extracted with the signal extractor with randomization
1977
1978 - callisto now finds the pulse position in the data automatically
1979
1980 - implemented data reduction in calibrated data by reducing the precision
1981 of the stored floating point values (pedestal, rms and signal) to
1982 roughly 0.5%
1983
1984 - fixed showplot to make file format conversion (eg. converting a
1985 status display stored in a root file into a postscript file) in
1986 batch mode possible:
1987 showplot -b --save-as-ps[=outfile.ps] infile.root
1988
1989 - Allow class names as part of filter rules, eg
1990 (MFSupercuts) && (MHillas.fSize>100)
1991
1992 - fixed a lot of stuff to allow all programs to process MonteCarlo
1993 camera files.
1994
1995 - enhanced possibility to debug reading of resource file
1996
1997 - MDataChain should handle priorities of operator more
1998 accurate now
1999
2000 - completely revised the container in which the signal is stored
2001 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2002 * the new implementation is faster and
2003 * needs less storage space
2004
2005 - FIRST version which can process Monte Carlos through the
2006 whole chain of programs (callisto, star, etc)
2007
2008 - implemented new image parameters for the border length of
2009 the shower image (MNewImagePar2)
2010
2011 - implemented wobble-mode in ganymed
2012
2013 - new class (MJOptimize) taking care of all optimization processes
2014
2015
2016
2017 *** Version 0.8.6 (2004/10/05)
2018
2019 - New combined signal and time extractor
2020 MExtractTimeAndChargeDigitalFilter
2021
2022 - The Report for the trigger section in the CC run summary has been
2023 updated, and now the IPRs (Individual Pixel Rates) are available.
2024
2025 - new macros for database interaction: filldotrun.C, filldotrbk.C
2026
2027 - added new program which can convert colored output which was redirected
2028 into a file back into colored text (for example to display it with
2029 more): showlog
2030
2031 - added new program to display an MStatusArray of plots (stored with
2032 MStatusDisplay) from a file: showplot
2033
2034 - Added support for Sequences (MSequence). Sequences are blocks of run
2035 files containing the same calibration and belonging to the same
2036 source
2037
2038 - Added a new task (MTaskEnv) which can be used in setup files to switch
2039 between different tasks (for example to choose a signal extractor)
2040
2041 - Implemented automatic file splitting in MWriteRootFile
2042
2043 - After image cleaning an island index is assigned to all used pixels.
2044 The index corresponds to the order of the islands in size.
2045
2046 - added a cleaning which takes signal height _and_ arrival time into
2047 account: probability cleaning (for more details see MImgCleanStd)
2048
2049 - added a cleaning which takes takes the absolute number of photons
2050 times the area ratio as cleaning level
2051 (for more details see MImgCleanStd)
2052
2053 - Changed calculation of image parameters such, that it can be done
2054 for all used pixels or the pixels with a defined island index only
2055
2056 - implemented new image parameters displaying the number of islands,
2057 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2058
2059 - event display in executable changed to support also calibrated files
2060 (done with MJCalibrateSignal)
2061
2062 - added program doing the calibration and the signal extraction
2063 and signal calibration: callisto Most part of the setup is done
2064 by a resource file: callisto.rc
2065
2066 - implemented support for pixels with negative IDs (Raw file format
2067 version 4)
2068
2069 - implemented an new option in merpp (--auto-time) to get the time
2070 range for cc and/or caco data from the run header of the raw data
2071
2072 - New star-program (star and MJStar). Taking calibrated data from
2073 callisto/MJCalibrateSignal as input. The setup is done through
2074 a resource file: star.rc
2075
2076 - Added possibility to setup the eventloop in the mars-executable
2077 Camera Display by a resource file: mars.rc
2078
2079 - The the mars-executable Camera Display can now also read
2080 calibrated data files written by callisto/MJCalibrateSignal
2081
2082 - Added a new class which can calculate the source position in
2083 the camera from a pointing model known to be correct and
2084 the pointing model used for observations (MSrcPosFromModel)
2085
2086 - added a new version of the class calculating the effective on-time
2087 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2088 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2089 MHTimeDiffTheta.
2090
2091 - added the possibility to count how often a signal is above (or
2092 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2093 can replace MHTriggerLvl0)
2094
2095 - added ore convinient ways to set the axis-titles of your histograms
2096 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2097 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2098
2099
2100
2101 *** Version 0.8.5 (2004/08/06)
2102
2103 - new Signal Extractors: MExtractFixedWindowSpline
2104 and MExtractAmplitudeSpline
2105
2106 - implementes interleave in merpp to be able to merpp parts of a file
2107
2108 - implemented force-functionality to merpp
2109
2110 - star display to display star catalogs (MAstroCatalog)
2111
2112 - star display to 'mirror' stars to the camera (MAstroCamera)
2113
2114 - implemented a new cleaning option which allows cleaning scaled with
2115 the real ratio of the rms depending on the pixel size, not only the
2116 square root of the pixelsize (MImgCleanStd, MCameraData)
2117
2118 - removed obsolete MBlind* classes
2119
2120 - Signal extractor taking the AB flag into account implemented (this makes
2121 an odd number of slices for signal extraction possible
2122 (MExtractSignalABcorr)
2123
2124 - implemented a class extracting the pedestal from the raw-data (events)
2125 itself using empty lo-gain (MpedCalcFromLoGain)
2126
2127 - Added mean values to MPedPhotCam
2128
2129 - Added Makefile for Darwin (this OS is NOT officially supported!)
2130
2131
2132
2133 *** Version 0.8.4 (2004/04/19)
2134
2135 - new fast arrival time extractor using cubic splines:
2136 MExtractTimeFastSpline
2137
2138 - implementes multi-argument support in MDataChain
2139 ("pow(a, b)")
2140
2141 - implemented double reference support in MDataChain
2142 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2143
2144 - added support in MF for expressiond like
2145 "MHillas.fWidth<2*<MHillas.fLength"
2146
2147 - MDataChain is now able to support variables like [0], [1], ...
2148 which can be used in fit functions as parameters. The interface
2149 is implemented through the new virtual function
2150 MParContainer::SetVariables
2151
2152 - added new class MArrivalTimeCam/MArrivalTimePix:
2153 Storage containers to hold the ArrivalTime of the camera/pixel
2154
2155 - added new classes for the calibration of relative arrival times:
2156 MCalibrationRelTimePix and MCalibrationRelTimeCam
2157
2158 - added new classes to extract the signal of the blind pixel and the
2159 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2160
2161 - added new classes for the bad-pixels treatment (MBadPixels*)
2162 which are more powerfull than the old ones (MBlindPixel*)
2163 and will replace them.
2164
2165 - added filter against cosmics: MFCosmics
2166
2167 - added new class MArrivalTimeCalc2:
2168 Calculates the arrival time as the signal weighted mean of the time
2169 slices in the maximum window
2170
2171 - added a new macro call pointspreadfucntion.C that fits with a 2D
2172 gaussian the DC spot for an star. It gives you the RMS of
2173 the PSF and the center of the star, very useful for misspointing
2174 studies.
2175
2176 - added support for multi-telescope camera files. Added classes
2177 MStereoCalc and MStereoPar, classes to calculate and store shower
2178 parameters calculated from the data of two telescopes, for the MC
2179 studies regarding the MAGIC clone.
2180
2181 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2182 MC data calibrated in photons instead of ADC counts.
2183
2184 - added three macros to show the calibration and analysis chain of
2185 MC data. The macro starmc.C does both calibration and analysis, producing
2186 an output containing Hillas parameters for each event. The macro
2187 mccalibrate.C does just the calibration and writes out a file containing
2188 pixel information in photons instead of FADC data. The macro starmc2.C
2189 reads in such a file and produces an output with Hillas parameters.
2190
2191 - added MPedPhotCalc to compute pedestals in units of photons, see
2192 macro pedphotcalc.C
2193
2194 - added all class to perform the calibration, see macro calibration.C
2195
2196 - added class MFFT to perform Fast Fourier Transforms
2197
2198 - added class MSimulatedAnnealing to perform simulated annealing
2199 minimizations
2200
2201 - added new macro bootcampstandardanalysis.C which holds the skeleton
2202 of the analysis chain discussed in the december bootcamp.
2203
2204 - added support for DAQ raw data file format V2
2205
2206 - implemented an arbitrary time stamp for the events from raw-data
2207 files with file version<3. It is calculated from the run number,
2208 the date of start and the FADC clock tick from the first module
2209
2210 - implemented the correct decoding of the event time-stamp
2211 coming from the DAQ for raw-data files with file-version>2
2212
2213 - added a new classes storing the pedestals in units of photons:
2214 MPedPhotPix, MPedPhotCam
2215
2216 - added support for DC current files from the camera control
2217
2218 - added support for start- and stop-time when merpping report files
2219
2220 - added MReportCC storing the weather data from the CC-REPORT
2221
2222 - added class to fill trainings and test matrices (MTFillMatrix)
2223
2224 - added a filter performing a software trigger (MFSoftwareTrigger)
2225
2226 - Added classes to perform parts of the standard analysis (Jobs):
2227 + MJPedestals
2228 + MJCalibration
2229 + MJExtractSignal
2230 Note: All of them are preliminary!
2231
2232 - Added Iterator to iterate over files giving only the run-number
2233
2234 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2235 the evolution of a sector vs time
2236
2237
2238
2239 *** Version 0.8.3 (2003/12/05)
2240
2241 - adapted Random Forest classes to allow the use with MC
2242 multi-telescope files which can be produced with the coming
2243 camera version 0.7.
2244
2245 - added classes to read and interprete central control report files
2246 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2247
2248 - enhanced merpp (the executable) to support .raw and .rep files.
2249
2250 - added classes for light calibration (MCalibration* and
2251 MHCalibration*) by Markus Gaug. Further work has to be and will
2252 be done soon.
2253
2254 - Added a preliminary 'synchronizer' (MReadReports) which will
2255 replace MReadMarsFile as soon as it is finished.
2256
2257 - Added a tutorial macro demonstrating how report files are merpped
2258 and how they can be read from the root file in the correct order
2259 of time (readrep.C)
2260
2261 - Added a generalized histogram (similar to MH3) called MVsTime
2262 which allows to plot variables (or rules - MDataChain - of
2263 variables) vs time. For an example have a look at tempvstime.C.
2264
2265 - Changed the name of the event trees:
2266 + Events --> Events
2267 + PedEvents --> Pedestals
2268 + CalEvents --> Calibration
2269
2270 - changed name of MTime in the event trees from MRawEvtTime to MTime
2271
2272 - added displaying the sector indices to the mars event display
2273
2274 - Magic Online Analysis (MOnA) implemented in a first version
2275 (see mona.cc, MOnlineDump and MOnlineDisplay)
2276
2277 - added classes to calculate event rate
2278 (preliminary: MEventRateCalc, MEventRate)
2279
2280 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2281
2282 - added classes dealing with the telescope pointing position (MPointing*)
2283
2284 - implemented the 'final' Mars time stamp based on some experiences with
2285 the new 'Synchonizer'
2286
2287
2288
2289 *** Version 0.8.2 (2003/11/10)
2290
2291 - accelerated standard analysis by a factor of 6-8 ...
2292 + doing precalculations in MGeomCam for the pixel area ratio
2293 + creating a look up table for the single pixels in MCerPhotEvt
2294
2295 - added task to calculates weights in case you want to 'change'
2296 the energy spectrum of a monte carlo file
2297 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2298
2299 - added a new executable star which implements the
2300 star.C macro as precompiled executable. Currently a flexible
2301 setup is not possible, but a 'input card' setup will follow.
2302
2303 - Starting to implement Multi-Telescope-Support based on the
2304 upcomming camera version 0.7. The base for a general support
2305 is implemented and the star-functionality is proven to work.
2306
2307 - Replaced Event-Display in and Camera-Display in the Mars GUI
2308 executable by a more convinient display base on MStatusDisplay.
2309
2310 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2311
2312
2313
2314 *** Version 0.8.1 (2003/10/20)
2315
2316 - added signal subtraction for pure on data by means of fitting
2317 the background in the off region or by performing a combined
2318 signal/background fit. Provides necessary histograms for
2319 obtaining energy spectra and a light curve.
2320
2321 - added classes to perform and study the selection of the
2322 2nd Level Trigger on MC data (example in triglvl2.C macro)
2323
2324 - added pedestal calculation
2325
2326 - implemented "democratic cleaning" (tail cut value proportional
2327 to pixel area) according to Wolfgang's suggestion.
2328
2329 - added Sigmabar treatment (calculation and basic histogramming)
2330
2331 - added basic routines to apply padding
2332
2333 - added first implementation of MARS-based source visibility plotter
2334 (needs to be linked against slalib, preliminary version)
2335
2336 - enhanced functionality of data chains: random numbers, conversion
2337 functions and access to MHMatrix objects
2338
2339 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2340 numbers under certain circumstances (runs with 0 events included)
2341
2342 - fixed a bug in the general filter MF (didn't work on some systems
2343 at all)
2344
2345 - fixed a bug in chaining files, which caused the analysis to crash or
2346 ignore files
2347
2348 - implemented more geometry classes describing the parameters used
2349 to simulate the PMT camera
2350
2351 - added new Monte Carlo classes containing the setup of the different
2352 programs in the MC chain.
2353
2354 - added a (preliminary) general task to evaluate chi-square of a given
2355 parameter in an eventloop.
2356
2357 - first implementation of a container describing the observatory
2358 location (Long, Lat, etc)
2359
2360 - added Random Forest - method for g/h-separation
2361
2362 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2363 (this means, that it is compiling, but not yet fully tested)
2364
2365 - added a new status display which can show the present status
2366 of histograms while an eventloop is running (MStatusDisplay,
2367 an example can be found at status.C)
2368
2369 - reorganized directories:
2370 classes describing the image --> mimage
2371 classes containing Monte Carlo Histograms --> mhistmc
2372 classes for Random Forest method --> mranforest
2373
2374 - added (event-)weights to fill histograms
2375
2376 - colors in logging output to screen
2377
2378 - changes to the Image Parameter declaration:
2379 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2380 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2381 + MHillasExt now derives from MParContainer instead of MHillas
2382 --> Files written with the old definition are more or less unreadable
2383
2384 - reading of reflector files
2385
2386 - display data from reflector files in the camera
2387
2388 - implemented currents (and display them in the camera)
2389
2390 - logarithmic scale in camera
2391
2392 - added class to iterate through directory contents (MDirIter)
2393
2394
2395
2396 *** Version 0.8 (2002/11/18)
2397
2398 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2399
2400 - corrected 48(!) wrong entries in the Next Neighbor table of the
2401 Magic Camera (all in the inner part of the outer ring, mostly
2402 missing a single NN)
2403
2404 - Fixed a bug in the table describing the Next Neighbours of the
2405 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2406 have any neighbour)
2407
2408 - changed trigrate.C: now it calculates the pure NSB triggers from
2409 a camera file (generated with no showers), so there is no need
2410 to introduce them by hand in the BgR array (for more details
2411 please ask Abelardo)
2412
2413 - added MHHadronness (and MHadronness) as a general facility to evaluate
2414 the quality of a gamma-hadron seperation method
2415
2416 - changed MWriteAsciiFile to accept rules (MDataChain)
2417
2418 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2419 must be replaced by calles to MWriteAsciiFile::AddColumn and
2420 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2421 changed.
2422
2423 - Implemented generalized event-matrices (one row per event)
2424 (MHMatrix)
2425
2426 - implemented the one dimensional composite probabilities
2427 (MHCompProb, MCompProbCalc, comprob.C)
2428
2429 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2430 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2431
2432 - Added a camera display displaying the pixel numbers to the
2433 event display gui.
2434
2435 - Added Monte Carlo Informations to event display gui
2436
2437 - Changed the camera display to display the pixel numbering
2438
2439 - Added three buttons to the camera display to change the palette
2440
2441 - Added the number of used and core pixels after image cleaning
2442 to MHillas
2443
2444 - Changed the algorithm used in MHillas according to TDAS 02-03
2445
2446 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2447
2448 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2449
2450 - Added fCosDeltaAlpha to MHillasSrc
2451
2452 - The numbers of photons used to calculate fConc and fConc1 in
2453 MHillasExt are now scaled with the pixel size, so that one get
2454 a four times smaller value for the bigger pixels in the outer ring.
2455
2456 - added new task to smooth the camera contents (MCameraSmooth)
2457
2458 - added possibility to use interpolated pixel values for blind pixels
2459 instead of removing it completely from the analysis
2460
2461 - Implemented the possibility to save the whole eventloop with
2462 its setup to a file. This information can be read and from
2463 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2464 and MEvtLoop::MakeMacro. If you find something not working, please
2465 report - this stuff is still in a beta phase.
2466
2467 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2468 file having crab starfield, but also for all following files - fixed
2469
2470 - MTaskList::PrintStatistics can now be instructud to print also the
2471 title, too: use PrintStatistics(0, kTRUE)
2472
2473 - Changed the image cleaning so that pixels with to many 'used'
2474 neighbors are left used (to get rid of 'holes' in events)
2475
2476 - Introduced more output to the camera displays
2477
2478 - Added an array of histograms (eg one hist per run), MHArray
2479
2480 - Added a _preliminary_ version of the reader for CT1 PreProc files
2481 (MCT1ReadPreProc)
2482
2483 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2484 (thanks to Raquel)
2485
2486 - added the first energy estimator (MEnergyEstParam, estimate.C,
2487 estfit.C) using a parametrization
2488
2489 - Added some new Monte Carlo paremeter containers used to store
2490 setup information from the MC chain (MMcConfigRunHeader,
2491 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2492
2493
2494
2495 *** Version 0.7 (2002/04/30)
2496
2497 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2498 the pedestal mean value was saved incorrectly. For files from
2499 this versions we substract 0.5 from the pedestal mean.
2500 WARNING: This may effect your results, so don't wonder...
2501
2502 - First implementation of an algorithm using only triggered events
2503 for the collection area calculation
2504
2505 - Ascii Output can now also be used for parameter containers which
2506 doesn't overload MParCointainer::AsciiWrite
2507
2508 - The Ascii Output is now also capable of writing single data members
2509 of one container
2510
2511 - You are now able to change the order of the values written to the
2512 ascii file
2513
2514 - You can now specify a conversion factor for each data member written
2515 to an ascii file. This may be usefull to change the units of the
2516 data member (eg. degrees instead of millimeters in case of the
2517 hillas parameters)
2518
2519 - Replaced old MHillas by a new structure which allows you to extend
2520 the parameters stored in MHillas very easily:
2521 see MHillas and MHillasExt
2522
2523 - Added classes to handle source dependancy of image parameters:
2524 see MHillasSrc
2525
2526 - Added container (MBinning) to have a standard input for the binning
2527 in different histograms (eg. the Energy bins should be the same in
2528 all histograms)
2529
2530 - Changed Hillas histograms from mm to deg
2531
2532 - Added the flexible binning to the hillas histograms
2533
2534 - Added a filter for the alpha parameter (MFAlpha)
2535
2536 - It is now possible to write single data members of a class object to
2537 an output stream instead of the whole container only
2538
2539 - Added a generalized filter for a data member:
2540 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2541
2542 - Added a generalized Filter parser for more difficult filter rules
2543 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2544
2545 - Added new Monte Carlo histograms:
2546 MHMcEnergyImpact and MHMcEfficiency
2547
2548 - Added many new histograms needed for the flux calculation.
2549
2550 - Added a generalized histograms which can fill and show up to three
2551 data members in either a one-, two- or three-dimensional histogram, eg:
2552 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2553
2554 - Added:
2555 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2556 * calculation of <Theta> as a function of time (MHThetabarTime)
2557 they are needed in the flux calculation in
2558 order to select for a given bin in Theta (or time) the appropriate
2559 effective collection area, which is assumed to be given as a function
2560 of Theta and the true energy
2561
2562 - Added calculation of the migration matrix in the energy
2563 (MHMcEnergyMigration):
2564 the migration matrix describes the migration from the true (E_true)
2565 to the estimated energy (E_est); it is needed to determine the
2566 distribution of E_true from the measured distribution of E_est
2567 by unfolding
2568
2569 - changed the color palette in the camera display to DeapSea.
2570
2571
2572
2573 *** Version 0.6 (2002/01/15)
2574
2575 - Introduce the option of disable pixels (MBlindPixels and
2576 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2577 able to deal with Star Field NSB.
2578
2579 - Fixed a bug in the pedestals substraction
2580
2581 - Introduced verbosity levels
2582
2583 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2584
2585 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2586 work correctly (thanks to Abelardo)
2587
2588 - Introduced correct treatment of the diffuse Night Sky Background
2589 and NSB (MMcPedestalNSB)
2590
2591 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2592
2593 - Introduced MMcRunHeaders which contains monte carlo run informations
2594
2595 - Added a 'Print'-Task (MPrint) which calls the Print function
2596 of a parameter container for each event
2597
2598 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2599
2600 - changes to be more efficient with root 3.02/06
2601
2602 - root 3.02/06 fixes:
2603 + the memory leak when reading MRawEvtData
2604 + loosing more time than necessary to update the progress bar
2605
2606 - MWriteAsciiFile is now capable of writing more than one container
2607 in a line. For example: To be able to write Monte Carlo and
2608 Hillas values (energy and alpha) in one line.
2609
2610
2611
2612 *** Version 0.5 (2001/11/06)
2613
2614 - Added new GUI functionality (Analysis)
2615
2616 - Added a camera display to be able to display events in the camera
2617 together with the calculated hillas ellipse
2618
2619 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2620 object at any state of the analysis, so that the output are several
2621 states
2622
2623 - Fixed a bug in the collection area error calculation
2624 (Thanks to Ciro and Abelardo)
2625
2626 - Fixed a bug which causes merpp to crash in some environments
2627
2628 - Implemented auto enabling scheme for Branches to speed up reading
2629 a lot (see MReadTree and MTask)
2630
2631 - Fixed a bug in the Histogram classes which caused histograms to
2632 be written to a file by MWriteRootFile without request
2633
2634 - changed the object I/O from the old stylish root I/O to the new
2635 'auto evolution scheme' This was done only for classes which are not
2636 yet used in Monte Carlo files, so that these files are still readable.
2637
2638 - Added support for a progress bar in MEvtLoop and MReadTree
2639 (see the Analysis Window in Mars for an example)
2640
2641 - Fixed a bug in the package creation which disturbed the conversion
2642 between a mars version unpacked from a tar file and the repository.
2643
2644 - Changed the code to writer merpped (converted into root format)
2645 raw files, to get faster (around 10%)
2646
2647
2648
2649 *** Version 0.4 (2001/09/20)
2650
2651 - This release is made to compile on a root version >= 3.00
2652
2653 - Fixed a bug which causes MReadTree to read the first file only
2654
2655 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2656
2657 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2658
2659 - Added a task to write several container to a root file (MWriteRootFile)
2660
2661 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2662
2663 - Added calculation of the collection area (MMcCollectionAreaCalc)
2664
2665 - fixed some bugs in the Hillas calculation
2666
2667 - added filters to be able to control the task execution dependent on
2668 a parameter (for example: the number of level 1 triggers in a MC-file)
2669
2670
2671
2672 *** Version 0.3 (2001/04/23)
2673
2674 - Many demo macros added
2675
2676 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2677
2678 - Hillas Calculation added
2679
2680 - Standard image cleaning available
2681
2682 - MReadTree is now able to handle more than one file
2683 (Remark: of the same structure)
2684
2685 - Now we are able to display events in a first version of the
2686 Camera event display. To do this we must run the macro
2687 "macros/readCT1.C" to read data from CT1.
2688
2689
2690
2691 *** Version 0.2 (2001/01/24)
2692
2693 - First Implementation of a Gui to read the raw data. Start the
2694 gui with the command mars.
2695
2696
2697
2698 *** Version 0.1 (2000/12/20)
2699
2700 - First official release 0.1
2701
2702 - Changes:
2703
2704 + changed calling style of MRawPixelIterator from do...while to
2705 while-loop