source: trunk/MagicSoft/Mars/NEWS@ 8942

Last change on this file since 8942 was 8942, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 116.9 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;Database
6
7 * introduced average temperature and wind speed from star-files
8
9 * introduced the ratio of accepted calibration events in the
10 calibration run
11
12 * introduced the average rates of the different trigger pattern,
13 e.g. the rate of pedestal and calibration events, from the signal-file
14
15 ;general
16
17 * fixed GroupBy options in plot*.C macros
18
19 * only display KVA points (not the Tuorla points) in plotoptical.C
20
21 * all programs now allow to add resources to the ones from the resource
22 file or overwrite them from the command line. This can be done like this
23 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
24 if something seems to be wrong you can debug what the program is doing
25 using the option --debug-env=3
26
27 * increased the diversity of debug levels. That also means that with -v3
28 you get now less output, i.e. only the output which is important for
29 an analysis. To get more output which helps for debugging try 4, 5 and 6.
30
31 * fixed a problem in the task synchronizing the reading of the reports
32 and the data stream. The effect was that in some circumstances the last
33 events of some trees could have been skipped. Since this is only a
34 very tiny part of the data no severe effect to your analysis results
35 is expected (an exception might be very short, i.e. singel runs,
36 datasets).
37
38 * Dataset file now allow to include the sequence file directly within
39 the dataset file and also allow to exclude single runs from the dataset.
40 (for more details see Class reference of MDataSet)
41
42 * Sequence files now allow for excluding runs from the analysis
43 (for more details see Class reference of MSequence)
44
45 * added code to process the sum-trigger flag
46
47 * the histogram classes MH3 and MHn now support profile histograms
48
49 * the histogram classes MH3 and MHn now support labels at the axis
50
51 * the Random Forest Train-classes (MJTRain*) now store the used datasets
52 in the output file
53
54 * the MFMagicCuts have a new option to allow a linear area cut (for
55 special studies)
56
57 * The liniking of the shared object is now done into a file defined
58 by 'mktemp'. This should be a local file system which accelerates
59 liniking a lot.
60
61 * The code has been prepared for compilation with root 5.18/00d
62
63 * The MHEnergyEst histogram now shows the distribution of
64 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
65 and (Eest-Emc)/Emc vs Emc.
66
67 * fixed mars (event display) for merpped raw-data and MC data
68
69 ;merpp
70
71 * Implemented cc file version 2008-20-02/0
72
73 * Added Pyrometer information to output (stored in a new Tree
74 Pyrometer, needs a complete new merpp, i.e. new calibration)
75
76 ;callisto
77
78 * in the pedestal processing now at least 50 processed events are
79 required for succeeding.
80
81 * the signal and calib files now contain also the sequence information
82
83 * the two MPedestalCam in the calib file now have proper names
84 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
85
86 * Both pedestal cams now conatain the number of events processed
87
88 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
89 i.e. for the extraction of the calibration pulses basically the average
90 over all events of the first slice instead of all slices was used.
91 Since pedestal and calibration constants are continously recalculated
92 this only effected the very first events of every sequence.
93
94 * For the extraction of the position of the maximum sample now the
95 extraction range is set automatically to the extraction window,
96 before the whole accessible range was used.
97
98 * If the number of samples in the events and the number of samples
99 in the run-header disagrees now an error is raised (this can
100 happen in not well simulated Monte Carlo files)
101
102 * In the case of MUX-data pedestal events with the lvl1 trigger flag
103 could survive into the pedestal calculation -- fixed.
104
105 * Tab "TrigPat" added showing the distribution of the trigger pattern
106 as found in the run-files (normalized with the run length)
107
108 * The selection of events from the trigger pattern has been improved.
109 If the trigger pattern is corrupted events won't pass anymore.
110
111 * Added a new command line option --dev-null to suppress output of
112 Y-files (this is useful for test cases)
113
114 * added a new tab "CalPos" showing the arrival time of extracted
115 interleaved calibration events
116
117 ;star
118
119 * the star file now contains also the sequence information
120
121 * Added a new command line option --dev-null to suppress output of
122 I-files (this is useful for test cases)
123
124 * Tab "Rate" added showing the distribution of the trigger pattern
125 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
126 the Y-files (normalized with the run length)
127
128 * The effective on-time calculation doesn't use events with only
129 sum-trigger anymore
130
131 * The data in the MHWeather tab has been reorganized. The never
132 working solar radiation has been removed and the data from
133 the pyrometer (cloudiness, air and sky temperature) is
134 displayed in addition.
135
136 ;ganymed/sponde
137
138 * Now data points are even shown correctly if they have error bars larger
139 than one sigma. Points with null or negative significances are omitted.
140
141 * DrawNicePlot now allows to set a projection range
142
143 ;sponde
144
145 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
146
147 * a new option "--force-runtime" is available. In case of very short
148 datasets (for light-curves) which are in the order of a few
149 minutes the calculated effective on-time is not very acurate because
150 it is quantizised in th eorder of a minute. Therefore you can switch
151 to using the real run-time instead (remakrt: this ignores any
152 dead-time!)
153
154 * a more analytical way is used to "fill" Monte Carlos into regions
155 of impact parameters which have not been simulated because the
156 trigger efficiency is assumed to be 0.
157
158 * estimated sensitivity curves for hi and lo zenith angles are shown
159 scaled to the correct observation time and collection area
160
161 * the Monte Carlo events after cuts are now written to the output file
162 if an output file given
163
164
165
166 *** Version 2.0 (2007/09/03)
167
168 - database: the position used for the pulse pos check was missing
169 in the callisto output and could thus not be filled into the DB.
170 Also the old values seemed not exactly the PulsePos used for
171 teh check.
172
173 - general: Resource file now allow an Include-Resource, i.e. you can
174 read a resource file with default settings, include it in your
175 resource file and overwrite the settings in your file. More than
176 one include file is allowed. Inclusions can be iterative.
177 Include: mydefaults.rc yourdefaults.rc
178 The resources in the first file have higher priority than the
179 second file.
180
181 - general: Now the output files (calib*.root, etc) also contain the
182 resource file (to check it open it in the TBrowser and choose Print()
183 from the context menu)
184
185 - general: Dataset files now allow to overwrite the default path
186 to search for sequence and data files. Note, that the program
187 option and individual resources will overwrite it. For example:
188 SequencePath: /magic/montecarlo/sequences
189 DataPath: /magic/montecarlo/star
190
191 - general: Fixed a problem with variables in MDataPhrase. It seems
192 that only optimdisp (didn't work) was effected.
193
194 - general: Some improvements to the optim and train processing. For
195 example the ststud window now got a proper title.
196
197 - general: The "Status Display: " was removed from the window title
198 within an Eventloop.
199
200 - general: added a new flexible histogram-class (MHn) which can be used
201 for example in testing after optimizations or training to produce
202 user defined histograms.
203
204 - general: The Random Forest now allows attaching an evaluation
205 function which is applied to its output. This allows to train
206 on whatever you like (eg. train on log10(energy), but return
207 energy)
208
209 - general: The Random Forest training of energy (trainenergy.c) and
210 disp (traindisp.C) has been improved by more graphical output to
211 judge the result.
212
213 - general: The training of energy (trainenergy.C) has been improved
214 a lot by training on a different quantity than energy. It gives
215 a result which is highly independant of the source spectrum
216 and shows lower bias than all other options.
217
218 - general: Dataset files are allowed to contain collections of
219 datasets. For more details see the class reference of MDataSet.
220
221 - general: The default WobbleMode in a datset file now (if not
222 overwritten) is "auto", i.e. wobble mode is set if the dataset
223 doesn't contain off-sequences.
224
225 - merpp: Merpp can read file format version 9 now. Please realize
226 that for file format version 9 the extraction range is different
227 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
228 the first and last 15 slices have been removed from all MUX data.
229
230 - mars: Similar to writing movies you can now select events which
231 should be displayed in your display. Therefore add the following
232 lines to your mars.rc:
233 MFEvtNumber.FileName: ganymed00223552.root
234 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
235 The input file can be a ganymed-file after (ganymed*.root) or
236 before (ganymed*-summary.root) file. For example to select all events
237 from your on sample after cuts (excluding the ThetaSq cut) use
238 MFEvtNumber.Selector: DataType.fVal>0.5
239 To show all events from your on-sample after quality cuts
240 use the summary file instead.
241
242 - mars: new ways to call mars are implemented. Instead
243 of calling
244 mars filename.root
245 you can now also use
246 mars sequence.txt
247 or
248 mars sequence.txt inputpath
249 or replace sequence.txt by the sequence number if the default
250 sequence file should be used.
251
252 - mars: The default size has been increased
253
254 - mars: There are two new heckboxes which allow to switch off
255 the calculated image parameters
256
257 - callisto: was broken for MCs... fixed.
258
259 - callisto: improved calculation of spline coefficients a lot. This
260 leads to a further improvement of the event rate calibrating MUX
261 data of about 15% (175evt/s instead of 150evt/s)
262
263 - callisto: finally the raw data we read is now real 16bit (with
264 10bit precision) for MUX data and not a stripped 8bit number
265 anymore. Due to scaling of the numbers (without precision loss
266 into an [0-256[ range, the final numbers for pedestal, pedestalrms
267 and extacted signal don't change. However, at all places where
268 raw data is directly accessed (eg. saturation and variation
269 limits in the signal- and pedestal-extraction) the numbers
270 refer still to the data's 16bit range.
271
272 - callisto: The maximum arrival time difference used in the bad
273 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
274 for both, old FADC and MUX-FADC, data.
275
276 - callisto: Be aware that callisto is now calibrating the arrival time
277 in nanoseconds rather than time slices. Also all following tasks
278 have been changed to assume ns units now. If you star data
279 calibrated with an older version it might be necessary to adapt
280 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
281 to obtain optimal results. The plot in the PulsePos tab
282 will now be in ns, too. This might also mean that the Muon
283 analysis in star might not work as perfect as expected as long
284 as old files read in.
285
286 - callisto: The calibration constants of earlier updates got lost
287 somehow. All constants have been updated.
288
289 - star: The PSF is now determined from the profile of the ArcWidth
290 instead of arcwidth/radius. The old way gave to much weight
291 to the bins with low statistics. The reference lines have been
292 updated.
293
294 - star: For speed reasons events suitable for the muon analysis
295 are now also preselected by fConcCOG<0.1 which seems to be a very
296 good preselector for muons.
297
298 - star: is now calculating a new timing parameter the Slope along
299 the major and minor axis of the shower. Therefore a numerical
300 solution of a line-fit is used. To use MHillasExt.fSlopeLong
301 and MHillasExt.fSlopeTrans don't forget to multiply it with
302 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
303
304 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
305 have been removed from MNewImagePar. They have never been good for
306 anything.
307
308 - star: Implemented a new recursive algorithm which is supposed to be
309 faster. Also implemented new cleaning oiptions, which are:
310 + CleanLevel0:
311 The cleaning level above single core pixels can be kept
312 + KeepIsolatedPixels:
313 Define whether single core pixels should be kept
314 + TimeLevel1:
315 The coincidence window in nanoseconds to single used neighbors
316 + TimeLevel2:
317 The coincidence window in nanoseconds to two used neighbors
318 + PostCleanType:
319 MOde in which a time dependent post cleaning should be applied
320 0: No post cleaning
321 1: Require for each used pixels at least one used neighbor
322 within a time-window of CleanLevel1
323 2: Require for each used pixels at least two used neighbor
324 within a time-window of CleanLevel2
325 3: Require first two and second one used neighbor
326 within a time-window of CleanLevel1 and fCleanLevel2
327 respectively
328 + RecoverIsolatedPixels:
329 - recoveres isolated core pixels if they have a used neighbor
330
331 - mars/star: The new default cleaning is:
332 + CleanLevel1: 6.0
333 + CleanLevel2: 3.0
334 + CleanTime1: 1.75
335 + CleanTime2: 1.75
336 + PostCleanType: 3
337
338 - star/ganymed: The old spark-cuts have been replaced by new ones.
339 These new spark cuts have been cross checked with the sequences
340 84720 (before splitter), 101041 (after splitter) and 223539 (new
341 FADCs). In all cases they seperate pretty well, but of course not
342 perfect. Monte Carlos have suggested to tighten the cuts a little
343 bit further at low sizes. This has been done.
344
345 - ganymed: IMPORTANT - The spark cuts have been changed to match
346 all available data more or less well. This might mean that for
347 YOUR data there are still sparks visible.
348 Whenever you do an analysis you have to make sure that NO sparks
349 survive your cuts!
350
351 - ganymed: The old hadronness and size cuts have gotten new indices
352 (10, 11). The old indices 8 and 9 now mean an additional condition
353 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
354 If you want to switch off this cut just move the line far away enough,
355 e.g. by setting c[9] to -500. Please update your ganymed.rc files
356 accordingly!
357 The unit of c[9] is deg. It is the dist at which your cut will
358 cross the slope==0. The unit of the slope is ns/deg. So if
359 you readin files calibrated with an older Mars-version you
360 have to adapt the default value for c[9] to the FADCs:
361 - Multiply by two for the MUX FADCs (run number > 200.000)
362 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
363 - Multiply by 42 for the meaning of life (run number = 200.000)
364
365 - ganymed: The old Cut0 is now called CutQ and is calculated before
366 the source position is caluclated. If you need a quality cut
367 including source dependant data (be very carefull with this!)
368 you have to use Cut0 instead.
369
370 - ganymed: now properly supports three off regions in wobble mode.
371 It will be the default from now on in ganymed_wobble.rc. To change
372 the number of off-regions use
373 NumOffSourcePositions: 1
374 in your ganymed.rc. Also by default no off-theta cut will be done
375 anymore so that you will get a background level higher than the
376 signal level in your ThetaSq plot for ThetaSq>0.2.
377 Due to this be carefull changing the scaling mode away from
378 "None". You will underestimate your signal if your scale interval
379 is not properly set.
380 (Rem: ThetaSqN is no longer needed)
381
382 - ganymed: is now storing the events of all (on- and off-)
383 source positions even in the case of more than one off-source
384 position. This should allow sponde to work properly and the
385 energy estimation is done correctly in all cases (without any
386 "nearest position" trick)
387
388 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
389 with a real pointing model for the starguider is done, calibrated
390 with more than thousand tpoints taken from this date on.
391
392 - ganymed: was broken for Wobble-MCs... fixed.
393
394 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
395 has changed. Note that your old ganymed.rc will be incompatible
396 with the new algorithms! Please check the ganymed.rc files and
397 the class description of MFMagicCuts for more information.
398 It is recommended at the moment to use identical Disp-Parametrizations
399 for on/off- and wobble-mode. If cuts are optimized only
400 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
401 should be optimized. All other values should be kept as they are.
402 If you want to do an anylsis without timing a parameters, you can
403 switch off the timing cuts by seeting parameter 7 to a very small
404 value (eg. -99). To remove the slope parameter from the disp
405 paremtrization set parameter 8 to 0.
406
407 - ganymed: The distribution of observation time versus zenith
408 angle is now shown for off- AND on-data.
409
410 - ganymed: The contents of the source position plot are no longer
411 averaged, thus a lot of (fake) events between the two wobble
412 positions have disappeared.
413
414 - ganymed: There is a new tab "CutT" it contains the VsSize plots
415 with the CutT, whihc is defined in ganymed.rc, applied. It
416 is resonable to use your theta-cut for it, to see if there is
417 something strange (sparks!) in your signal-region.
418
419 - ganymed: To choose a dataset from a collection in a dataset file
420 use the new command line option "--dataset=12345"
421
422 - optim, sponde: should now properly support three off-regions.
423 Just produce your ganymed summary files with three off-regions.
424 optim and sponde will automatically get all off events from
425 all off-regions from this file. Please do not forget to
426 set the scaling in optimwobble.C properly:
427 fit.SetScaleUser(1./3);
428 it is not yet read in automatically (will follow soon).
429 In the case of fixed Scale you can also use
430 cuts.SetThetaCut(MFMagicCuts::kOn);
431 no off-cut needed.
432 Be carefull in case of three off-regions when switching on
433 scale mode. Make sure that the scale interval is set correctly.
434
435 - sponde: sponde.rc and sponde_onoff.rc are now idetical
436
437 - sponde: the resouce files have been rewritten with a lot of
438 comments and a well working parametrization for an energy estimator
439
440 - sponde: In the estimated energy versus monte carlo energy plot the
441 contents where exchanged.... fixed.
442
443 - sponde: the so called "accurate"-mode has been removed. It didn't
444 give any improvement in accuracy, only decreased execution speed.
445
446 - sponde: the so called "simple"-mode has been removed. It didn't
447 give any improvement in simple.
448
449 - sponde: the so called "refill"-mode has been removed. It was anyhow
450 not implemented.
451
452 - sponde: now checks whether the theta distribution of your on-data
453 and the theta-distribution of your Monte Carlo sample (after
454 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
455 sample is incomplete) execution is stopped. Execution can be forced
456 using the new option --force-theta. Use this option with care!
457
458 - sponde: Proper collection areas can now be constructed also from
459 Monte Carlo samples generated with different maximum impact
460 parameters. Note that in previous version you neither got
461 a warning or failure, nor was there any obvious sign that the
462 collection area was overestimated due to usage of files with
463 different maximum impact parameters.
464
465 - sponde: If MC files with different lower energy limits are used
466 the primary MC spectrum is artificially completed down to the
467 lowest energy used at all. WARNING: that this gives correct
468 collection areas ONLY if none of the events in this region would
469 survive your cuts at all.
470
471 - sponde: the output file now contains more information about
472 the spectrum (eg. the full 2D collection area histogram).
473 Note, that this information can only be written to the file
474 if it is stored automatically via command line argument.
475 If you only store the status display from within the display
476 the information is lost.
477
478 - sponde: added a new tab "Disp". It shows the residual of the disp
479 (Disp-Dist) versus several parameters and it is meant to judge the
480 quality of the disp estimator. In the ideal case the residual is zero
481 and doesn't depend on any variable. The tab is displayed after
482 CutQ and Cut0.
483
484 - sponde: added a new tab "Energy". It shows the residual of the
485 energy (lg(estimated energy)-lg(monte carlo energy)) versus
486 several parameters and it is meant to judge the quality of the
487 energy estimator. In the ideal case the residual is zero
488 and doesn't depend on any variable. In reality even a good estimator
489 can show residuals versus Monte Carlo energy. The tab is displayed
490 after all cuts.
491
492 - sponde: added a new tab "EventDist" showing the unweighted real
493 absolute number of events of your sample after cuts. This tells
494 you how many events with this energy you had in your MC files.
495 The same information you get from the error bars of the weighted
496 histograms, but this is less intuitive.
497
498 - sponde: The spectrum plots now show the crab- and 1553-spectrum
499 for comparison. It is not meant to show these curves in
500 publications, they are only for production.
501
502 - sponde: The OriginalMC tree with the events produced by corsika
503 is now processed only once
504
505 - sponde: Finally fixed most annoying bug, which has effected the
506 last bin of the collection area. It was the problem that binnings
507 of root histograms are from 1 to n (included) but there was a C-like
508 loop in sponde from 0 to n (excluded). Now the loop also includes
509 correctly under- and overflow-bins. The worse thing with this is,
510 that for the events in the highest bin not only the bin-content
511 was wrong, but also the weights applied to these events, which could
512 in pricipal effect also other parts of the distribution (eg. due
513 to energy estimation). Fortunately it effected only a few events
514 in most cases.
515
516
517
518 *** Version 1.2 (2007/05/14)
519
520 - database: The database now has two new values Unsuitable50 and
521 Unsuitable01. They express the number of pixels which are
522 unsuitable for more than 50%, respectively more than 1%, of
523 all calibrated event. It is a more accurate number than the
524 previously used numbers, because they only take the first
525 calibration (ignoring the interleaved calibrations) into account.
526
527 - database: The database now has two other new values UnsuitableMax and
528 DeadMax. They express the maximum number of pixels which were
529 unsuitable, respectively dead, during the sequence. Because
530 of high pedestal rms (cars passing) a few events with very high
531 numbers of unsuitable pixels can happen. Not to suffer from this
532 effect we don't take the highest 0.1% of the numbers into account.
533
534 - general: fixed a bug which caused callisto and star to stop working
535 properly because the callisto output was currupted
536
537 - general: a script called scripts/makemovie has been added which
538 simplified the process of producing several movies from a single
539 sequence with different setup.
540
541 - callisto: Some more code cleanup. Started to remove old obsolete
542 code from cvs.
543
544 - callisto: The extraction of the pedestal with the extractor was
545 not random. It seems that extracting at one position is still biased
546 (for example in the first or last slices we could still suffer from
547 switching noise) Now it is completely random.
548
549 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
550 pedestal files) individual pixels could be skipped due to high
551 variations. This was already the case for the pedestal extraction
552 from the lo-gains since the beginning and properly handled
553 there, but was introduced in the extraction from the pedestal files
554 a while ago. To calculate the average value it was still divided
555 by the number of events procesed not by the number of summands
556 really summed. This let to a pedestal which was a tiny amount too
557 small (for a few piels in the order of 0.1%). This led to an slightly
558 positive offset of the randomly extracted pedestal for a few pixels.
559 I doubt that this has a big effect on the result, because the effect
560 on the individual numbers is quite small. Due to this it is suggested
561 that you rerun your calibration to make sure you are without any
562 avoidable bias.
563
564 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
565 the median rms of the absolute arrival time and expressed in significance
566 levels. This replaces the old meaning of an abolute upper limit. An
567 absolute upper limit doesn't make much sense, because in our data
568 all arrival times are shifted at the same time (in fact it might be
569 a shift of the artificial trigger w.r.t. to the light flash).
570
571 - callisto: Added a new tab "BadPixTm" which shows the time evolution
572 of the number of unsuitable pixels over the whole sequence. This
573 is usefull mainly to judge if an intermediate calibration had
574 problems.
575
576 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
577 of the number of dead pixels over the whole sequence. Dead pixels
578 in this context are unmapped pixels, i.e. pixels which could not
579 be interpolated, and thus are ignored in the further analysis.
580
581 - callisto: It is now possible to use the position of the maximum
582 of the spline as arrival time instead of the leading edge even
583 when using the integral for the signal. Therefor set the extraction
584 type to kIntegralRel ("IntegralRelative") and the relative height
585 ("HeightTm") to -1:
586 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
587 MJPedestalC1.ExtractSignal.HeightTm: -1
588
589
590
591
592 *** Version 1.1 (2007/04/27)
593
594 - general: The new class MGeomCamDwarf contains the camera geometry
595 for our prefered Dwarf camera and can be used to create general
596 geometries of roundish or hexagonal cameras.
597
598 - mars: The default cleaning is now abolute 8.5/4.0.
599
600 - mars: The resource file mars.rc now contains examples for MUX data
601
602 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
603 data containing only 10-bit information is still cooked down to
604 8-bit, by cutting away the lowest 8-bit.
605
606 - merpp: When reading raw data the data is now stored in a single
607 array. The lo-gain array is obsolete. The interface stays the same.
608
609 - callisto: To process the new MUX data use the resource file
610 callisto_mux.rc
611
612 - callisto: The -root and -raw options to read merpped raw data have
613 been removed
614
615 - callisto: If the -mc option is given the sequence-name can now be
616 replaced by the MC sequence number
617
618 - callisto: If the sequence file contains "MonteCarlo: Yes" the
619 -mc option can now be omitted
620
621 - callisto: Started further simplification by removing obsolete
622 dependancies on MCalibIntensity*Cams.
623
624 - callisto: removed unsused intensity calibration from MJCalibration
625 for further simplification
626
627 - callisto: for simplification removed references to
628 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
629 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
630 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
631 (this should at minimum change nothing at all, and at maximum
632 improve thing if these containers where somewhere not handled
633 properly)
634
635 - callisto: Added the option to write an event movie. Please use
636 this option with care (huge files) but exessively to understand
637 our events. For further documentation please refer to the
638 IACT wiki
639 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
640
641 - callisto: Improved binning for the pulse position check histogram
642
643 - callisto: The code calculating the pulse position checknow takes
644 the pedestal into account
645
646 - callisto: The arrival time is now stored with full precision this
647 helps to get rid of artefacts in histograms. For the signal this
648 is not necessray because it is displayed in log-scale anyhow
649
650 - callisto: Fixed a problem with internal exclusions. Pixels which
651 have once been marked as unsuitable didn't get the necessary
652 histograms filled anymore to be rechecked with each interleaved
653 calibration.
654
655 - callisto: The relative arrival time resolution (the rms of the
656 relative arrival time offset) is now checked against its
657 median and the median deviation, instead of the average
658 plus an absolute offset.
659
660 - callisto: The relative arrival time offset is now calculated
661 w.r.t. its median not w.r.t. to an artificial reference pixel.
662
663 - callisto: The relative time calibration now marks pixels with
664 outlaying offset as unsuitable
665
666 - callisto: The interleaved relative time calibration has been switched
667 on. The advantage is that pixels which are marked as outliers
668 now can recover. An improvement over time is not expected, because
669 the relative time calibration seems stable.
670
671 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
672 option can now be omitted.
673
674 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
675 or the option "-mc" is specified as default the monte carlo datacenter
676 paths (/magic/montecarlo/...) are used if not overwritten in the
677 dataset file.
678
679 - ganymed: The output files now contain run- and event-number for all
680 events, accessible as RunNumber.fVal and EvtNumber.fVal
681
682 - ganymed: Added a plot showing the source position in the camera also
683 for wobble mode
684
685 - ganymed: In addition to the existing task which can be setup to
686 be executed after Cut1 a final task called "EstimateEnergy"
687 has been added, executed before writing the final output
688 (ganymed00000000.root). The task setup in all three cases
689 can be choosen individually. (For all three(!) cases you
690 can for example choose MRanForestCalc. For examples see all
691 sponde*.rc and all ganymed*rc)
692
693 - ganymed: If a container "MEstimatedEnergy" is found in the
694 parameter list (eg. because it was setup by MEstimateEnergy)
695 it will be written to the output file.
696
697
698
699 *** Version 1.0 (2007/02/16)
700
701 - database: Website to plot values from the database has been added.
702
703 - database: The rate of spark events as found by star is now kept
704 and the rate after cleaning is now with spark events subtracted
705
706 - general: The changes to the interpretation of phrases lead to
707 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
708
709 - general: Added example files how you can create your own calendar
710 (eg. as christmas present) with Mars. Just run
711 root macros/tutorials/calendar.C
712
713 - general: Added a possibility to display grouped data in the plotdb.C
714 macro (and similar macros). This allows to plot hourly, nightly,
715 weekly, monthly and yearly averages.
716 For more details see the plotall function of the macro
717
718 - general: fixed the error display of the camera display. It showed
719 wrong results.
720
721 - general: fixed a memory leak when reading many MStatusDisplays
722
723 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
724 between a spherical and a parabolic mirror
725
726 - callisto: We have a new pulse position check which takes the properties
727 of the extractor automatically into account. So no need to set
728 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
729 left is done. If possible the lo-gain extraction start and hi-gain
730 extraction end is changed accordingly. If no proper extraction range
731 can be set (hi-gain too much to the left) an error is raised.
732
733 - callisto: New swapped pixels have been found and corrected
734
735 - callisto: Redone the signal extraction this includes:
736 + Unified the algorithms to extract the pedestal for all pedestal
737 extractions done
738 + Unification of hi- and lo-gain into one array
739 + Unification of hi- and lo-gain extraction for Spline and
740 Digital Filter (means now exactly the same algorithm is used,
741 not a copy-and-pasted one)
742 + Store pedestal subtracted data in a common place
743 + Improved extraction algorithms. If the algorithms search a
744 maximum but don't find one they don't return the maximum anymore
745 + Improved the extraction such that a information for signal
746 and time which is consistent is returned
747 + replaced the numerical spline with a (not slower) analytical
748 solution
749 + Lowered the saturation limit from 250 to 245 to make sure that
750 we are far away in all pixels from problems with the clock-noise
751 + The start of the lo-gain extraction is calculated from the hi-gain
752 arrival time. In case of saturation an estimation is used.
753 + the hi-gain window was extended to slice 16. This allows extraction
754 of very late pulses in single pixels or of huge hadron showers.
755 + Now uses the lo-gain extraction range for pedestal extraction,
756 not the hi-gain range in the lo-gain
757
758 - callisto: New hi-/lo-gain calibration constants have been produced
759 for all periods from the statistic of the whole period. They are
760 now used automatically depending on the periods. The old constants
761 where deviation in avarega about 2%-3%. The constants are very
762 stable from period to period (<<1%) except for exchanged channels.
763 In a few cases the constants used so far were off by 1%-2% (maybe
764 temperature effects?)
765
766 - callisto: To gain obsolete space we do not write the
767 MPedestalFundamental anymore. Also calibration and bad pixel
768 treatment is not done for it anymore because it has never been used.
769
770 - callisto: Fixed a bug in the seuqence handling which caused the
771 light condition to be ignored
772
773 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
774 basically the same as "Cleaned" but the distribution devided into
775 the events fullfilling a spark cut or being rejected by it.
776 This cut can be changed from star.rc (see example inside) by
777 the "SparkCut" directive
778
779 - star: Star displays now the average individual pixel-rate (IPR) versus
780 time and the average discriminator threshold (DT) of all pixels.
781
782 - optim: fixed a problem with the optim-macros which was due to a bug
783 in the new phrase parsing
784
785 - ganymed: To get a nice FalseSource plot (instead of the all-information
786 debug plot displayed as a standard plot) use the context menu
787 somewhere between the two upper plots, click on "DrawNicePlot"
788 and enjoy the result. (It is the same context menu which contains
789 the other options)
790 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
791
792 - ganymed/optim/train: The cut program, trainings- and optimization
793 macros could run with less files found than expected from the
794 sequence-files. No the execution is stopped in this case.
795
796 - ganymed: now stores the dataset in the output file with all information
797 contained (as sequence number, sequence path, data path) so that the
798 used dataset file can be recreated complete from the output
799
800 - sponde: now also allows the uasge of random forest
801
802 - sponde: added a plot showing the cut efficiency
803
804 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
805 errors (eg. effecting the collection area) because the errors of the
806 two histograms were swapped in the calculation, which makes a difference
807 in the case the histograms contains weighted events. Aditionally the
808 totalarea was incorrectly taken into account, which results in too small
809 errors, which makes a difference at low statistics were the errors
810 or the collection area dominate.
811
812
813
814 *** Version 0.10.3 (2006/10/23)
815
816 - database: Implemented ObservationMode flag in websites.
817
818 - database: For sequences there is now also the stoptime available on the
819 websites.
820
821 - database: Removed ManuallyChanged flag from sequence-info websites,
822 as it is not needed anymore with the new sequence building algorithm.
823
824 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
825 Class for calculation of confidence intervals (upper limits).
826 Use model 3 or 4 for upper limit calculation for MAGIC observations.
827 Please read the class instruction of TRolke for more information.
828
829 - general: The programs now return 0xfe if the requested resource file
830 doesn't exist.
831
832 - general: Errors comming from root itself are now not output to
833 stderr anymore but to our default (colored) log-stream.
834
835 - general: Changed the interface to TFormula such that now everything
836 is parsed by TFormula, which should allow to use phrases even
837 without paranthesis correctly parsed.
838
839 - callisto: replaced the AdHoc number of effective integration slices
840 in the digital filter by an average of the correct number, averaged
841 over all possible set of weights. This also gives correct numbers
842 for the lo-gains which were totally wrong before.
843
844 - callisto: drastically reduced memory consumption by not storing
845 all intermediate calibration results in memory anymore (we might
846 write them into a file in the future)
847
848 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
849 debug plot displayed as a standard plot) use the context menu
850 somewhere between the two upper plots, click on "DrawNicePlot"
851 and enjoy the result. (It is the same context menu which contains
852 the "DrawAll" option)
853 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
854
855
856
857 *** Version 0.10.2 (2006/10/15)
858
859 - general: changed the building of the sequence files such, that
860 the source-/project name in case of wobble-sources is not the
861 source/project of the first data run anymore but the new generalized
862 wobble source/project
863
864 - general: Added some functions to MAstro to calculate sun and
865 moon properties
866
867 - general: Added two new macros (starvisday.C and starvisyear.C)
868 which allow to plot the visibility of several stars in one day
869 or of one star along one year
870
871
872
873 *** Version 0.10.1 (2006/10/11)
874
875 - general: HTML logging output was distorted... fixed.
876
877 - general: Changed the writing of the sequencefiles such that only
878 as many pedestal files as giving at least 1000 pedestal events which
879 are nearby the first calibration run are used as pedestal runs
880
881 - sponde: In the calculation of the collection area(s) and the
882 distribution for MOnte Carlo and estimated energy the error
883 calculation was wrong because root didn't take the errors
884 properly into account... fixed.
885
886
887
888 *** Version 0.10 (2006/10/10)
889
890 - general: all executables now check consistency of the root version
891 installed with the root version used for compilation. The return
892 code in this case is 255.
893
894 - general: The algorithm to build seqeunces has been redesigned
895 completly. It is now more flexible in terms of a resource file
896 resources/sequences.rc which can be used to partly overwrite
897 the default algorithm and defined the important part of the
898 algorithm. It also takes correctly into account several ways
899 of taking wobble-data. Currently the new algorithm doesn't take
900 the number of pedestal events anymore into account (so a sequence
901 could have much less than 1000 pedestal events and data runs are
902 no-more used instead)
903
904 - general: a lot of small changes to make the code compatible with
905 root 5.12/00 and gcc 4.1
906
907 - general: Fixed some warnings thrown if more warnings are switched
908 on in the compiler
909
910 - general: Added a function to MMath which returns the Median of
911 the distribution abs(y[i]-median) but at 68:32 division instead
912 of 50:50, which is somehow the median counterpart of the rms.
913
914 - general: MAstroCatalog allows now to read calatog files (as bsc5)
915 even if they are compressed with gzip (recommended compression
916 is with "-1")
917
918 - showplot:
919 + batch mode creation of image files now works with root 5.12/00
920 + added support for writing bmp (though it never produces
921 bmp which can be read by programs like xv or gimp)
922 + added support for xml
923 + added new option to start the display with a different size, by
924 --display-width=nnn or --display-height=nnn
925 + added options to define the canvas size when the display is started
926 --canvas-width=nnn or --canvas-height=nnn
927 the option can also be used for batch-mode conversion
928 + added an option which automatically fits the display size to the
929 desktop-size: --auto-size
930
931 - merpp: didn't recognize files with the extension .raw.gz - fixed.
932
933 - merpp: allow the reports to have 1000ms due to a bug in the camera
934 program.
935
936 - callisto: New swapped pixels have been found and corrected. For
937 details see MRawRunHeader::FixAssignment()
938
939 - callisto: Callisto now raises an error if one of the input files could
940 not be opened.
941
942 - callisto: In some rare cases it could happen that in the signal
943 extraction of the digital filter the extractor returned nonsense
944 results due a wrong initializion of a variable (this happens in
945 cases in which the extracted signal is exactly zero or the
946 digital filter couldn't slide because of a too small extraction
947 window, which could happen in the lo-gain extraction)
948
949 - callisto: The lo-gains have been marked as valid in some cases
950 when they got not extracted at all (deltsumlo=deltatimelo=0) because
951 the allowed extraction range (fLoGainLast-fLoGainFirst) was
952 smaller than the number of slices (fLoGainWindowSize) needed
953 by the lo-gain extractor
954
955 - callisto: Updated absolute calibration constants (muon calibration)
956
957 - callisto: fixed a bug which caused the hi-gain saturation not
958 to be handled properly in the spline (the position of the
959 saturation was calculated incorrectly)
960
961 - callisto: fixed a bug which gave weird results if hi- _and_
962 lo-gain could not be extracted properly. In some cases hi-
963 and lo-gain have not been extracted at all and the random result
964 got calibrated. In other cases the hi-gain was saturating and the
965 lo-gain has not been extracted. For this a completly arbitraty
966 scale factor was applied to the result from extracting the
967 charge of the saturating hi-gain.
968
969 - callisto: improves handling of extracted signal if lo- and/or
970 hi-gain could not be extracted properly. If no appropriate
971 calibration of either the signal or the arrival time is possible
972 the pixel is now markes as unsuitable instead of estimated.
973
974 - callisto: Fixed a problem in the spline extraction which gave
975 weird results if the signal was extracted from the first (and
976 highest) slice (as a workaround extraction from the first
977 slice has been forbidden)
978
979 - callisto: Fixed a bug regarding the use of the QE which doesn't
980 effect the result because the default is used anyhow.
981 (The bug was there since 14/07/2005)
982
983 - callisto: Changed the default for fgLoGainStartShift to -2.4
984
985 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
986 factors to be always 10 for all pixels as soon as the first
987 calibration update has happend.
988
989 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
990 was off by more than one slice (which gives wrong values for
991 pixels which have saturated the hi-gain) This was a problem
992 mainly for timing studies, not so much for the automatic standard
993 analysis. Also the values for the Spline have been changed slightly:
994 + Digital Filter from 1.70 to 0.95
995 + Spline from 1.39 to 1.30
996 The numbers were sorted out by an extensive test in the
997 test-database.
998
999 - callisto: Removed the tab showing the average calibrated arrival
1000 time. It never gave useful information.
1001
1002 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1003 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1004 and both were extracted because the hi-gain was above the
1005 LoGainSwitch.
1006
1007 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1008 lo-gain pulse position (after application of LoGainOffset, which
1009 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1010 have saturated and both were extracted because the hi-gain was above
1011 the LoGainSwitch.
1012
1013 - callisto: After extensive tests a new threshold level for determination
1014 of the pulse position has been found at 50phe. This is due to the
1015 fact that for lower pulses the arrival time changes its average
1016 behaviour dramatically. It tends to the average of the extraction
1017 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1018
1019 - callisto: Added two more plots to the calibration part. The average
1020 extracted signal and the average extracted arrival time as
1021 extracted by the signal extractor (This can help debugging problems
1022 because it doesn't involve a fit)
1023
1024 - star: changed the fit for the effective on time such that initial
1025 values are calculated automatically now instead of using build
1026 in values. This makes the fit more indepedant of the underlaying
1027 rates. With a test of ~350 sequences in the test database it could
1028 be shown that the new fit gives the same result +/-1sek.
1029 The highest deviation was +5s the lowest -10s. You can now control
1030 the bahaviour with two resource values:
1031 MHEffectiveOnTime.FistBin: 3
1032 MHEffectiveOnTime.NumEvents: 12000
1033 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1034 from the resulting gamma candidates
1035
1036 - star: The Center histogram in MHHillas is now by default displayed
1037 with the colz draw-option
1038
1039 - ganymed: now produces valid error codes if failed
1040
1041 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1042 with the option "hadronness" instead of "area" or "both" if
1043 you want to use both cuts. The hadronness cut includes a fixed
1044 cut in hadronness (index 8) and a fixed cut in size (index 9).
1045
1046 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1047 the M3Long of the anti source to be not properly evaluated
1048 (actually is was evaluated as a unique random number) in case
1049 of optimization with anti-theta cut switched on. This might have
1050 lead to improper, but not necessarily wrong, optimization results.
1051
1052 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1053 how to use random forest
1054
1055 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1056 ganymed_onoff.rc. Seems to be unintentional that they were different.
1057
1058 - sponde: Since the introduction of the possibility to define a
1059 normalization energy instead of using the integral the default
1060 was not using the integral anymore but a normalization energy of
1061 1GeV. It is now the integral again.
1062
1063 - sponde: Fixed a problem in the weighting which did not allow
1064 a MC slope of -1.
1065
1066
1067
1068 *** Version 0.9.6 (2006/05/24)
1069
1070 - general: changed the binning of the azimuthal profile of the camera
1071 such that it is aligned with the 60deg boundaries.
1072
1073 - merpp: better handling of problems with the TH, TD part of the
1074 CC-REPORT for files older than 200507190 and 200412210
1075 respectively
1076
1077 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1078
1079 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1080
1081 - callisto: if an arrival time is extracted outside the fadc range is
1082 was set to the boundary before. Now a random number is assigned
1083 instead to avoid unfortunate coincidences of arrival times just
1084 by this arbitrary value.
1085
1086 - callisto: added a new option to callisto.rc which allows
1087 to set the maximum arrival time difference allowed for the
1088 badpixel algorithm to determin whether a pixels belongs to a shower:
1089 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1090
1091 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1092 to 0.9 as suggested by Stefan due to a recent study on the fraction
1093 of pixels surviving the image cleaning
1094
1095 - callisto: switched off error in case of "pulse is too much to the left"
1096
1097 - callisto: The extraction window is not adapted anymore. This means that
1098 the pulse is extracted from the full range. The draw-back is that the
1099 background (pedestal) will become slightly higher. Switching on/off
1100 the PulsePosCheck in the callisto.rc only effects filling the
1101 histograms.
1102 WARNING: If the pulse is too much to the left data is calibrated!
1103 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1104 in the database to make sure that your data is valid!
1105
1106 - star: Show also the number of stars correlated correctly by the
1107 starguider
1108
1109 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1110 than one off-source region in wobble-mode. To use it add the following to
1111 your ganymed_wobble.rc:
1112 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1113 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1114 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1115 + Cut1.ThetaCut: None
1116 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1117
1118 - ganymed: in the case the latest report is older than a default (currently
1119 one minute) and the current report will be skip the starguider
1120 correction and calibration will be reset. The maximum age can be
1121 setup from ganymed.rc by (minutes):
1122 MPointingDevCalc.MaxAge: 1.5
1123
1124 - ganymed: A first implementation showing all size-bins for the theta-sq
1125 resp. alpha-plots in a single tab automatically
1126
1127
1128
1129 *** Version 0.9.5.1 (2006/05/05)
1130
1131 - general: Added a new option "zdiff" to the Makefile which runs
1132 "cvs diff" as "make diff" would do, but with compression
1133
1134 - general: accelerated MTFillMatrix (used for eample in all training
1135 and optimization macros) by skipping some obsolete calles in the
1136 eventloop the first and second loop could be accelerated by ~20%
1137
1138 - general: Added a missing feature in the MFilterList class which
1139 prevented MFEnergySlope from working correctly in trainenergy.C
1140
1141 - general: Accelerated the random forest training and usage a bit
1142
1143 - merpp: Adapted to new raw data file format version 6
1144
1145 - merpp: fixed a problem with reading the starguider reports
1146 after 6.3.2006
1147
1148 - callisto: At some times six pixels had to be exchanged manually in the
1149 data. If the pixels to be swaped are both not found, an error was raised
1150 and calibration was stopped. Now it is assumed they are intentially not
1151 mapped and the Error has been changed to a Warning.
1152
1153 - star: Added new image cleaning based on the arrival time of the shower.
1154 The new cleaning can be accessed using the parameter "Time" instead of
1155 the the old one (like "Absolute) in the star.rc-file.
1156 Recommended parameters:
1157 + MImgCleanStd.CleanLevel1: 8.2
1158 + MImgCleanStd.CleanLevel2: 5
1159 + MImgCleanStd.CleanRings: 2
1160 + MImgCleanStd.KeepSinglePixels: No
1161
1162 - star: Simplified the calculation of the effective on time. By letting
1163 the fit start in the third bin the result should become more stable.
1164 The fit quality is now ignored for the theta-plot which is not used
1165 in the analysis later. Still better pre-cut which, for example,
1166 remove events triggered by car-light (rate changing on a short
1167 time-scale) are missing.
1168
1169 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1170 for optimization (kWeakSource) which is suggested by the Berlin
1171 people for weak sources.
1172
1173 - macros: plotdb.C:
1174 + if no dataset and no time-interval is given only sequences with
1175 an effective on-time above five minutes are plotted anymore
1176 + added a new tab "RelTime" displaying the relative on-time
1177 (effective on-time divided by the observation time)
1178
1179 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1180 the optimization became a lot faster
1181
1182 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1183 To display them just delete the pads displayed on top.
1184
1185 - ganymed: fixed a bug which could cause strange behaviour in wobble
1186 mode if no starguider information was available due to an incorrect
1187 initialization of the starguider calibration
1188
1189 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1190 be changed from within the plot. It can also be setup from the
1191 resource file using:
1192 + MHDisp.fScaleMin: 0.325
1193 + MHDisp.fScaleMax: 0.475
1194
1195 - ganymed, showplot: Fixed a problem with the fit to the off-data
1196 (HistOff) which could cause a time lag or an inifinite loop.
1197 The bug did not effect the results at all.
1198
1199 - sponde: Added a new tab showing the effective collection area after
1200 trigger (including the software trigger)
1201
1202 - sponde: MMcSpectrumWeight has a new option which allows to define
1203 the scaling factor not by the integral of the events but at
1204 a defined energy:
1205 e.g. MMcSpectrumWeight.NormEnergy: 200
1206
1207 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1208 eventloops the loop could be accelerated by ~20%
1209
1210
1211
1212 *** Version 0.9.5 (2006/03/13)
1213
1214 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1215 and added the standard Disp-parametrization
1216
1217 - macros: added a new macro datacenter/macros/plotstat.C allowing
1218 to plot statistics about the data processing
1219
1220 - macros: added a new macro to plot the muon correction coefficients
1221 versus period (macros/plot/mucal.C)
1222
1223 - showplot: path inflation for ganymed files was broken
1224
1225 - callisto: Fixed an important bug. When the number of saturating pixels
1226 were calculated the bad pixel information already available from the
1227 calibration was ignored. This yields wrong values in case pixels
1228 are broken and saturate all the time or randomly.
1229
1230 - callisto: Updated Muon calibration constants. Spline data now also uses
1231 different values for different periods
1232
1233 - star: The time-evolution shown in the effective on-time plot now displays
1234 the axis range (if there are no holes it should be similar to the
1235 effective on-time)
1236
1237 - star: Added two new image parameters:
1238 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1239 the three pixels next to the center of gravity and the size
1240 + MNewImagePar.fConcCore: The ratio of the signals of all
1241 pixels inside or touching the ellipse and the size
1242
1243 - ganymed: now stops in requested source isn't found in catalog file
1244
1245 - ganymed: Many improvements to the phi-plot in wobble mode:
1246 + with a template the ideal background is displayed
1247 + a possible camera inhomogeneity is taken into account
1248 + the anti theta cut is better supported
1249 + the phi cut is automatically calculated from the theta cut
1250 See the examples in ganymed_wobble.rc for more details.
1251
1252 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1253 times the bin-width instead of the absolute energy
1254
1255 - ganymed: New cuts for on/off and wobble mode
1256
1257 - ganymed: The smearing of the False Source plot has been increased
1258 to 0.06
1259
1260 - ganymed: The starguider calibration can now be changed from the
1261 resource file.
1262 See the examples in ganymed*.rc for more details.
1263
1264 - ganymed: added a new option for on-/off-observations
1265 MJCut.RandomSourcePosition
1266 If switched on the distribution of observation time of the source
1267 position in the camera is calculated from the on-data and randomly
1268 applied with this distrbution to the off-data.
1269
1270 - ganymed: by skipping some obsolete calles in the eventloop the
1271 first and second loop could be accelerated by ~20%
1272
1273 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1274 position in the off-data randomly according to its distribution in the
1275 on-data.
1276
1277
1278
1279 *** Version 0.9.4.3 (2006/02/13)
1280
1281 - general: Fixed a bug in most of the programs which prevented the
1282 compile date in the startup message to be displayed
1283
1284 - general: Simplified program calls. The following abbreviations
1285 are now possible:
1286 showlog callisto 55599
1287 showplot signal 55599
1288 star 55599
1289 callisto 55999
1290 ganymed 2
1291 In this cases the corrsponding root-, log-, sequence- or dataset-
1292 filename is automatically compiled using the default datacenter
1293 paths ("/magic/*")
1294
1295 - general: Fixed a long outstanding bug which made axis tick marks
1296 disappear if MDataFormula was used (eg. abs(x))
1297
1298 - general: Updated MMath with new functions to calculate the results of
1299 a exponential, logarithmic and powerlaw fits analytically.
1300
1301 - general: Updated some macros with comments:
1302 + macros/optim/optimdisp.C
1303 + macros/optim/optimenergy.C
1304 + macros/optim/optimwobble.C:
1305
1306 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1307 files) now allows adding a pre-cut like in the optimization. E.g. this
1308 is useful to perform g/h-separation cuts before training the random
1309 forest.
1310
1311 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1312 correctly assigned in the raw data assignement table. A fix to correct
1313 the assignment tabel have been implemented.
1314
1315 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1316 by 90, 180 and 270 deg.
1317
1318 - general: the macro plotdb.C now allows to highlight sequences belonging
1319 to a datset. For more details see the descritions in the macro.
1320
1321 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1322 of the display, it gave wrong results espacially for big sizes.
1323 Now the embedded canvas should always have a ratio width/height=3/2.
1324 The "Size" options have been updated with values fitting the 3/2
1325 size ratio.
1326
1327 - RanForest:
1328 + Updated the random forest classes to support also the
1329 regression method implemented by Thomas H.
1330 + added new tutorial macro how to train the random forest
1331 for energy estimation (macros/optim/rfenergyest.C)
1332 + new classes to train the random forest (still in development)
1333 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1334 + new tutorial macros for random forest training in macros/train
1335 trainenergy.C, traindisp.C, trainseparation.C
1336
1337 - mars: now allows to setup a cut in the resource file mars.rc to choose
1338 the events to be displayed, eg:
1339 Cut.Condition: {0} && {1}
1340 Cut.0: MHillas.fSize>100
1341 Cut.1: MHillas.fSize<900
1342
1343 - merpp: Made aware of the new .rep format 200510250. This includes
1344 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1345 the discriminator thresholds (MCameraTD) and the disciminator
1346 delays (MCameraTD). All of them come with the CC report and are therefor
1347 written to the CC tree.
1348
1349 - callisto: fixed a bug in the calculation of the arrival times in
1350 the Digital Filter. They were all shifted by the same amount
1351 fHiGainFirst. This caused an offset in the order of the position of
1352 the left border of the extraction window in the times calculated
1353 from high-gain and from low-gain. The bug effected only the absolute
1354 arrival times. The bug was there since 30.1.2005.
1355
1356 - callisto: Changed the ExtractionWindow for the pulse position check
1357 such that the camera inhomogeneity becomes as less as possible and
1358 comparable to the pulso position check switched off. More details
1359 on the study will be given at our result web-page.
1360
1361 - ganymed: ganymed.rc, ganymed_onoff.rc:
1362 changed to new cuts trained with 1ES1218 and Crab-data
1363 for maximum sigma*log10(excess)
1364
1365 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1366 a new option was implemented to estimate Disp (CalcDisp)
1367
1368 - ganymed: Implemented two new options which allow
1369 to overwrite the default path to search for the sequence files
1370 --ins=/magic/sequences
1371 and where to search for the image data
1372 --ind=/magic/data/star
1373
1374 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1375 dx/dy from the resource file by
1376 MSrcPosCorrect.Dx
1377 MSrcPosCorrect.Dy
1378
1379 - ganymed: fixed reading the source catalog. Only as many chars
1380 as the requested source name had were compared (If a source
1381 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1382 were requested it could happen that the coordinates of
1383 "1ES1218" were read) The source coordinates are now printed
1384 in addition to its name to the logging output.
1385
1386 - ganymed: changed the background fit in the case of a ThetaSq function
1387 from a polynomial to a exponential, this should give a big improvement
1388 for on-only analysis'
1389
1390 - ganymed/sponde: Calculation of the error of single size-/energy-
1391 bins now uses Li/Ma (5) instead of LiMa (17)
1392
1393 - sponde: Added a plot E^2*dN/dE
1394
1395 - sponde: The energy estimator plot should now show values like
1396 they are commonly used.
1397
1398 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1399 (a powerlaw with cutoff didn't work before)
1400
1401
1402
1403 *** Version 0.9.4.2 (2005/10/01)
1404
1405 - general: added new tutorial macro macros/tutorials/threshold.C:
1406 how to calculate the threshold
1407
1408 - general: added a new game. Start it from the interpreter with
1409 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1410 and MagicReversi)
1411
1412 - general: neighbor pixels in MGeoms are now sorted clockwise
1413
1414 - merpp: made aware of new format 20050829-0
1415
1416 - callisto: New scale factors from muon analysis, stored in new
1417 resource file resources/calibration.rc
1418
1419 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1420 the eventloop if something went wrong. This is necessary for the
1421 automatic processing
1422
1423 - callisto: Implemented a new treatment for the time information
1424 developed by S.Ruegamer, this should give much better response than
1425 the old very primitive algorithm. This is especially important
1426 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1427 treatment was buggy! As neighbor pixels to interpolate the
1428 arrival times always the pixels 0 to 5 were taken)
1429
1430 - callisto: In addition to the new treatment of arrival times the
1431 decision of the treatment whether a pixel contains shower
1432 information or not is used to improve the signal interpolation
1433 further. Previously interpolated pixels showed a non-zero signal
1434 do the peak searching signal extractors. Having a signal pixel
1435 beside raised the signal above the cleaning level. Thus the
1436 pixel survived cleaning to often but with a too low mean signal.
1437 By replacing empty pixels with a gaus (mean and rms from the
1438 corresponding Area entries in MPedPhotCam) this effect can
1439 be supressed.
1440
1441 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1442 got lost when the events were stored by the calibration... fixed.
1443 (This was no problem for normal image cleaning because the pixel
1444 content was artificially set to 0 not surviving standard cleaning
1445 algorithm)
1446
1447 - callisto: Fixed a bug which caused the random and peak-search pedestal
1448 extracted with an extractor to be exchanged for the first (roughly)
1449 500 events (*Extractor and *ExtractorRndm).
1450 (They were simply exchanged in callisto.cc) This bug might have been
1451 introduced in Mars 0.9.4 when the order of calculation of the two
1452 types of pedestal in callisto got exchanged. The bug only effects
1453 the first seconds of data of each sequence.
1454
1455 - star: Taking the arrival time of Muons into account the calculation
1456 of the parameters could be made independant of the noise
1457 (pedestal rms). The dependance was due to the bias of the peak search
1458 extractor. Now only a ZA dependamcy is left which is not yet fully
1459 understood.
1460
1461 - ganymed: The sequences were still not sorted correctly in any case,
1462 because they were sorted by the full qualified path name. Now they
1463 are sorted by their sequence number.
1464
1465 - ganymed: new values for the spark-event-cut
1466
1467 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1468
1469
1470
1471 *** Version 0.9.4.1 (2005/08/18)
1472
1473 - callisto: fixed some problems with the calibration in case of
1474 inteleaved events. Therefor the final and some intermediate
1475 fits are skipped which would take place on partly filled #
1476 histograms and gave wrong results or failed completely.
1477
1478 - callisto: If the intermediate finalization of the histograms
1479 calculating the mean charge of the calibration signal fails
1480 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1481
1482 - ganymed: Fixed some bugs which caused problems in On-only mode.
1483 Still the false source plot doesn't give reasonable results.
1484
1485
1486
1487 *** Version 0.9.4 (2005/08/05)
1488
1489 - general: Fixed the ZA binning. It did not correctly fit the
1490 MC binning
1491
1492 - general: Added a class to correct for the missfocussing in
1493 April (MSrcPosCorrect)
1494
1495 - general: Random Forest energy estimator should now work properly
1496
1497 - general: MHCamera now displays the profiles in deg instead of mm
1498
1499 - general: MH::SetPalette offers a lot of new palettes
1500
1501 - general: MHillas - the case of CorrXY==0 is now handled properly
1502
1503 - general: implemented the possibility to change the line and
1504 marker style of a sky-grid drawn by MAstroCatalog
1505
1506 - general: Runs in sequences and datasets are now automatically
1507 ordered (it is assumed that the order of their filenames correctly
1508 represents the order of observations) to ensure correct reading
1509 of the subsystem data
1510
1511 - general: Runs cannot be added to a sequence twice anymore. Also
1512 Sequences cannot be added twice anymore to a dataset.
1513
1514 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1515 It gave wrong results by 1./2pi
1516
1517 - showplot: got a new option to start a root interpreter, too
1518
1519 - mars: now displays a rough estimate of Disp and the third moment
1520
1521 - mars: now displays the event time MTime if available
1522
1523 - mars: show muon parameters graphically
1524
1525 - mars: now the file to open can be given as commandline
1526 argument
1527
1528 - merpp: Added support for new arehucas version >= 200507190
1529 implementing values for three temperature sensors in the
1530 counting house (MCameraAUX) and the name of the HV settings file
1531 (MCameraHV).
1532
1533 - merrp: Also fixed some problems with wrong versions numbers stated
1534 by arehucas and implemented some fixed for old versions (<200407070)
1535
1536 - callisto: MCalibrationHiLoCam can now be printed from its context
1537 menu, eg in the TBrowser
1538
1539 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1540 - 1.39 (MExtractTimeAndChargeSpline)
1541 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1542 This is important mainly for timing studies.
1543
1544 - callisto: Changed limits in MHCalibrationChargeCalc from
1545 - -100.125 to -98 (fgChargeHiGainFirst)
1546 - 1899.875 to 1902. (fgChargeHiGainLast)
1547 - -100.25 to -99 (fgChargeLoGainFirst)
1548 - 899.75 to 901. (fgChargeLoGainLast)
1549 Introduced new limits:
1550 - fgNumLoGainBlackoutLimit: 0.05
1551 - fgLoGainBlackoutLimit: 3.5
1552 - fgLoGainPickupLimit: 3.5
1553
1554 - callisto: The handling of automatic weights for the digital filter
1555 has been improved. There are now new calibration weights special
1556 for Monte Carlo calibrations.
1557
1558 - callisto: Updated Muon scale with latest results (1% difference
1559 for most data, 5% for Mar/Apr'05)
1560
1561 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1562 was saturated and the blackout-events in the low-gain exceed the
1563 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1564 This excludes those pixels which have a saturating high-gain
1565 channel, but the low-gain switch does not switch often enough
1566 to make the distribution reliable.
1567
1568 - callisto: fix a bug counting the number of saturated events. Up to now,
1569 the number of saturated slices was counted (which is one for a not too
1570 high number), but for some (pathological) pixels, many more slices
1571 saturated and produced wrong limits.
1572
1573 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1574 + MCalibrationRelTimeCam.CheckFitResults: Yes
1575 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1576 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1577 + MCalibrationRelTimeCam.CheckOscillations: Yes
1578
1579 - callisto: introduce max. number of events for intercalibration,
1580 the rest gets skipped. Default: 4096
1581 The calibration causes too many un-reliable pixels if more
1582 than about 5000 events are treated (@500 Hz) because of the
1583 mode hopping of the VCSels. However, in the past, some
1584 calibration runs have been taken (erroneously) with more
1585 than 5000 events, especially the intensity scans where
1586 a good precision is needed.
1587
1588 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1589 photo-electrons for the spline extractor by 1-2% (correctly).
1590
1591 - callisto: The intercalibration is now done using a full f-factor
1592 method instead of a simple update. This makes things slower but
1593 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1594 changes.
1595
1596 - callisto: MPedestalY3 now uses the same extraction range as the data
1597 as calculated by MPedestalY2
1598
1599 - callisto: A check of the fraction of allowed unsuitable (10%) and
1600 unreliable (30%) pixels has been addded when the conversion is
1601 calculated from interleaved events
1602
1603 - star: fixed a bug which caused MEffectiveOnTime containers not to
1604 be written. In the worst case they were skipped almost all, in the
1605 best case they were all ok. It depends on how often the new value
1606 was assigned just with an event which was skipped later by another
1607 task
1608
1609 - star: new histograms MHPointing and MHRate
1610
1611 - star: New tab (Currents) displaying the time evolution of the mean
1612 DC currents
1613
1614 - star: New tab (MeanRms) displaying the time volution of the mean
1615 Pedestal Rms
1616
1617 - star: Output now contains MReportStarguider
1618
1619 - star: Improved muon analysis. Due to the absense of a constant
1620 for the gaus fit for arc width and the fact that the arcwidth
1621 plot was a histogram instead of a profile the resulting psf
1622 became pedestal rms dependant
1623
1624 - ganymed: added new plot (MHPhi) for wobble mode as described in
1625 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1626
1627 - ganymed: corrects now (correctly?) for the misspointing in
1628 May/April 05
1629
1630 - ganymed: Two new default templates for ganymed.rc are avilable:
1631 ganymed_onoff.rc and ganymed_wobble.rc
1632
1633 - ganymed: The first version of MFMagicCuts has been released
1634
1635 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1636
1637 - ganymed, sponde: There are two new options to determin the number
1638 of bins for the signal region (NumBinsSignal) and the number of
1639 total bins (NumBinsTotal) in the MHThetaSq histogram
1640
1641 - ganymed: optimized palettes for MHDisp
1642
1643 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1644 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1645 sqrt(2) to large
1646
1647 - ganymed: The false source plot (MHDisp) is now based on Disp
1648 and a background model determined in the first loop is
1649 subtracted
1650
1651 - ganymed: MFMagicCuts are now available in the cvs. The correct
1652 solution for the disp ambiguity problem is now calculated using
1653 the third moment. The third moment cut therefor is skipped.
1654
1655 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1656 already determined by the third moment along the major axis and
1657 so its actual sign is aligned along the major axis of the shower.
1658
1659 - ganymed: If starguider data is available it is taken into account
1660 when calculating the source position. This is especially important
1661 for wobble data at high zenith angles and culmination data.
1662
1663 - ganymed: If available the starguider data is taken into account as
1664 good as it is possible without a starguider calibration. To switch
1665 it off add
1666 MPointingDevCalc.MaxAbsDev: -1
1667 to your ganymed.rc
1668
1669 - sponde: the zenith angle distribution is now weighted instead of
1670 choosen by default. This gurantees higher statistics in the highest
1671 and lowest energy bins. To switch this behaviour off use...
1672
1673 - sponde: now automatically displays the energy threshold
1674
1675
1676
1677 *** Version 0.9.3 (2005/06/03)
1678
1679 - general: MMcEvt now derived from MMcEvtBasic which should
1680 have no influence on compatibility with older camera files
1681
1682 - general: Implemented a new option to MReadReports which allows
1683 to force reading of the first event of some trees (eg. Drive-tree)
1684 before any other tree.
1685
1686 - general: Made a fix to MPointingPosCalc which assumes that the
1687 run-type is real-data if Process is called before ReInit, such
1688 that also the very first Drive-events in a run are treated
1689 correctly.
1690
1691 - shoplot now displays the filename in the title bar of the window
1692
1693 - merpp: new options: --auto-time-start --auto-time-stop which
1694 allow to cut updating with slow-control at the start- or
1695 (previousle --auto-time only allowed: and) stop-time of
1696 the run stored in the runheader.
1697
1698 - callisto: changed default of fgFallTimeHiGain in
1699 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1700 already set as default in callisto_Dec04Jan05.rc
1701
1702 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1703 now changes the filename for new weights automatically for
1704 cosmics, MC and for different calibration colors.
1705
1706 - callisto: a problem with the order of some code cause the
1707 name of the weights file in MPedestalY2 to be ignored.
1708 Wrongly the calibration_UV weights were used instead
1709 of the cosmics weights set in callisto.rc.
1710
1711 - callisto: should allow ct1 pulser data when the color is
1712 explicitly set also for pretty new runs
1713
1714 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1715 to introduce an additional scale factor (should be around 1)
1716 to adapt for slight deviations in different extractors from
1717 the MC calibration. For MC calibrations the scale factor
1718 is fixed to 1
1719
1720 - callisto: MFCosmics should handle very high signals a bit
1721 more accurate now
1722
1723 - callisto: when calculating the mean pedestal rms for different
1724 pixel sizes or sectors also kUnsuitableEvt is now taken into
1725 account - not only kUnsuitableRun
1726
1727 - callisto: '-raw' option is now the default
1728
1729 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1730 This has the advantage that mean values in the calibration (eg
1731 arrival times) are calculated more accuratly.
1732
1733 - callisto: In the resource file callisto_Dec04Jan05.rc
1734 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1735
1736 - callisto: new Hi-/Lo-Gain intercalibration constants
1737 hilocalib_sp1.root and hilocalib_sp1_mc.root
1738
1739 - callisto: changed default for MJPedestalY2.MaxEvents
1740 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1741
1742 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1743 has changed from 9.0 to 6.0. This is necessary to exclude two very
1744 ringing pixels in September which - when kept - destroy the image
1745 cleaning around them (Markus G.)
1746
1747 - callisto: (!) The Muon analysis of all data taken so far has
1748 suggested that different extractors give slightly different
1749 absolute results after calibration, due to there different
1750 handling of the calibration- and cosmics pulse shape. Although
1751 the over all calibration seems to be a bit to pesimistic (or
1752 the MC seems to be a little bit - 3-5% - too much attenuated).
1753 There for correction factors have been introduced which correct
1754 the calibration constants by
1755 0.956937799 for Digital Filter (callisto.rc)
1756 and
1757 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1758 calibration. The main advantage is, that both data types can
1759 be easily analysed together and compared to the same MC sample.
1760 The factors are choosen such, that the reference is now a
1761 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1762
1763 - star: fixed a bug which caused the first bin of the histograms
1764 vs time to disapear in PostProcess. This gave wrong results
1765 on the screen. The output and all following programs not
1766 directly accessing the histograms haven't been affected
1767
1768 - star, ganymed: Made sure that always the first Drive-tree event
1769 is read and Processed before the first data event was read.
1770
1771 - ganymed: implemented the possibility to replace the standard
1772 false source plot with a different one. For example: If
1773 you want to use a Disp based FS plot use the resource:
1774 NameHistFS: MHDisp
1775 For details about the requirements of these plots look
1776 at the corresponding classes
1777
1778 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1779 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1780 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1781 case MAlphaFitter is setup correctly. For On-Only optimization
1782 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1783 RunOn() instead of Run(). For energy estimation MJOptimize
1784 has been replaced by MJOptimizeEnergy
1785
1786 - sponde: The input MC spectrum can now be weighted to fake a
1787 different spectrum. This is done via MMcSpectrumWeight. For
1788 more details see the class description and sponde.rc
1789
1790 - sponde: The paremeter comparsion plots are not scaled by
1791 their entries anymore. Instead the MC plot is scaled by using
1792 the result spectrum of the analysis. If the input MC spectrum
1793 and the result spectrum has different slopes the absolut
1794 normalization is normally wrong.
1795
1796
1797
1798 *** Version 0.9.2 (2005/05/20)
1799
1800 - general: Changed the default paths for calibrated data and image
1801 files. (The implemented access to these files doesn't yet exist)
1802
1803 - general: support for MRunIter has been removed from the job classes
1804 (use the setter functions of MSeqeunce instead)
1805
1806 - general: ProcessFile has been renamed to Process in all job classes,
1807 because ProcessFile is missleading
1808
1809 - general: The storage of the palette in MHCamera is now possible
1810
1811 - general: new bits describing unsuitable and unreliable pixels have
1812 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1813 kDeadPedestalRms, kFluctuatingArrivalTimes
1814
1815 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1816 versions newer than V200404070
1817
1818 - general: support for cc file versions newer than V200504130. Added
1819 support for active loads (MCameraActiveLoad) and central pixel
1820 (MCameraCentralPixel)
1821
1822 - general: added new histograms for image parameters versus size
1823 (MHVsSize)
1824
1825 - general: The eventloop now automatically calls PrintStatistics
1826
1827 - Status Display: Improved support for printing:
1828 + A default can now be set in .rootrc (for more details see
1829 MStatusDisplay::PrintPS)
1830 + A print dialog is opened so that printer and command line
1831 can be canged
1832
1833 - showlog: improved such that it handles different verbosity levels
1834 more accurate now. This mean you can suppress output when
1835 using showlog.
1836
1837 - showplot: improved
1838 + The new graphics formats have been implemented
1839 (pdf, svg, png, jpg and xpm)
1840 + Implemented an interface for printing. Because you can change
1841 the printing command from the command line you can use all
1842 the nice postscript tool. To print a booklet for example call:
1843 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1844 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1845 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1846
1847 - callisto: fixed a bug in the recognition of the calibration bit
1848 pattern. Concerns only intensity calibration. (The strength of the
1849 intensity has been updated in some cases)
1850
1851 - callisto: add a filter against PIN Diode events when running over
1852 calibration runs since some of the recent calibration runs have
1853 been taken with Pin Diode.
1854
1855 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1856 39943, 44833 in the calibration (MCalibColorSet)
1857
1858 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1859 been set to 1e-18 in callisto_Dec04_Jan05.rc
1860
1861 - callisto: in callisto_Dec04Jan05.rc: set value for
1862 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1863 statistics for the calculation of the mean pulse time
1864 of the cosmisc
1865
1866 - callisto: the charge limit in the calibration has been raised
1867 from 2.5 to 4.5
1868
1869 - callisto: new setup read from callisto.rc
1870 + MCalibCalcFromPast.fNumEventsDump
1871 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1872 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1873
1874 - callisto: MExtractTimeAndChargeSpline extractor:
1875 + The integration ranges were shifted by 0.2 FADC slices to the right.
1876 + unreliable handling of floating point values caused different
1877 results on different platform or with different compiler options:
1878 The new algorithm is numerically exact and more accurate because
1879 it doesn't calculate the integration position by multiple times
1880 adding the step-size (which results in numerical uncertanties
1881 exspecially if multiplied with large numbers)
1882 + A lot of fixes have been introduced which effects integrating the
1883 spline at the edges of the valid range. In this case any memory
1884 was randomly accessed. This behaviour can be tested replacing
1885 all MArrayF by TArrayF which perform a range check (but of course
1886 they are a lot slower)
1887 ! No result obtained with the Spline before can be trusted! Due to
1888 random memory access it might by completely random!
1889
1890 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1891 + extraction range in the high gain to 4.
1892 + weights file to cosmics_weights46.dat
1893
1894 - callisto:
1895 + introduce the check for fluctuating arrival times.
1896 + set charge limit to from 2.5 to 4.5
1897 + introduce asymmetric exclusion due to "deviating number of phes":
1898 Default: -9.0 +4.5
1899 + make deviating number of phes unsuitable (see David's findings).
1900
1901 - callisto: fixed the display of unsuitable pixels. The old change
1902 to a real profile in MHCamera broke it.
1903
1904 - callisto: The cosmics filter is used in MJCalibration now
1905 independant of the pulser color (formaly it was used only for
1906 CT1-pulser data). The threshold of number of max empty pixels
1907 has been raised from 2% to 5% in MJCalibration. The maximum
1908 fraction of rejected event is 50% otherwise the calibration has
1909 failed. The filter now ignores unsuitable pixels.
1910 Setup the filter from callisto.rc using "ContCosmics"
1911 (see MFCosmics::ReadEnv)
1912
1913 - callisto: changed default for fgOffsetFromLogain back
1914 from -2.8 to -1.8 in digital filter.
1915
1916 - callisto: for the common extractors
1917 + MExtractFixedWindow
1918 * MExtractTimeAndChargeSlidingWindow
1919 * MExtractTimeAndChargeSpline
1920 * MExtractTimeAndChargeDigitalFilter
1921 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1922 and fResolutionPerPheLoGain
1923
1924 - callisto: Updated the hi-/lo-gain intercalibration constants
1925 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1926 hilocalib_df6.root
1927
1928 - callisto: The default lo-gain extraction window for the
1929 MExtractTimeAndChargeSlidingWindow extractor has been increased
1930 from 6 to 8 to take the stretch of the pusle into account
1931
1932 - callisto (!!!): fixed an important bug in the setting of the
1933 incoming pedestal pointer to the signal extractor extracting
1934 pedestals. This bug caused the pedestals not to be subtracted
1935 correctly in the calibration afterwards. The effect was about 10%
1936 too high conversion factors for the digital filter and the spline
1937 and more than 40% for the sliding window.
1938 The bug existed since end of February! (Markus G.)
1939
1940 - star: added muon support to star. A new tab "MHMuonPar" is
1941 displayed. The lower right plot is an estimate of the point spread
1942 function. A reference value is displayed. To get the real PSF
1943 you must compare with MC. The setup for the muon analysis
1944 is done in star.rc. More informations can be found in
1945 MHSingleMuon and MHCalibParCalc
1946
1947 - star: The weather data is now displayed in star
1948
1949 - star: MEventRateCalc handles the calculation of the event rate more
1950 accurate now in case of the start of a new run inside a sequence
1951
1952 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1953 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1954 changed only minimally
1955
1956 - ganymed: (MJCut and MJOptimize) now displayes the number of
1957 excess events versus size. The energy estimation is done in
1958 MJSpectrum (sponde)
1959
1960 - ganymed: got support for using other variables than Alpha, eg. Theta.
1961 Therefor you need a class deriving from MHAlpha which supports
1962 this variable (one is already existing: MHTheta, which is now the
1963 default in ganymed). It is setup through ganymed.rc
1964
1965 - added a full featured spectrum program (sponde) which reads
1966 ganymed output and monte carlos and compiles a spectrum
1967
1968
1969
1970 *** Version 0.9.1 (2005/04/14)
1971
1972 - Fix bug on the arrival time reconstruction when using Digital
1973 Filter (in some marginal cases (10%) times were reconstructed shifted
1974 by 0.2 slices)
1975
1976 - all executables now return 2 where in previous versions -1 has
1977 been returned (gave problems with shell-scripts)
1978
1979 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1980 also done with a intercalibration input file
1981
1982 - a bug in the time fine adjustment of the digital filter has been fixed
1983
1984 - a lot of small fixes to calling TPad::Divide with a margin==0
1985
1986 - MStatusDisplay now shows the memory usage
1987
1988 - added a memory leak statistic after the eventloop
1989
1990 - MHadronness replaced by MParameterD
1991
1992 - MEnergyEst replaced by MParameterD
1993
1994 - wobble mode can now be switched on from the data-set
1995
1996 - switched on bad pixel detection for a pedestal level
1997 which is more than 5 times the variance
1998
1999 - Fixed default paths to be correct for the new data center
2000
2001 - Fixed handling of drive data. The pointing position in now
2002 copied to MPointingPos inside star for real and MC events
2003
2004 - made sure, that the sequences in a dataset are sorted by
2005 their number to ensure the correct synchronization
2006
2007 - added all resource files necessary to handle spline extraction
2008 of signal for the late 2004 and the early 2005 data
2009
2010 - update the reference lines for the december data
2011
2012 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2013 This is important for the Dec. and Jan. data where the calibration
2014 pulse position changes much.
2015
2016 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2017 filter. This corrects only an defective extraction of the MC at
2018 low-gain signals lower than 90 phes.
2019
2020 - fixed some slowdown in calibrating data with interleaved events from
2021 Jan and Dec. As a workaround made the pretty palette the default.
2022 The inverse Deep Blue Sea has a bug which slows down long calibration
2023 runs a lot.
2024
2025 - implemented new values from new starguider report as defined
2026 in TDAS00-07 V7.1 (eg SkyBrighness)
2027
2028 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2029 in starguider report (If you merpp the same reports with this version
2030 you'll get the correct units (arcmin) but a different result
2031 than with old versions (wrong units))
2032
2033 - Now the status display can also write PNG, JPEG and XPM (other file
2034 formats are still unsupported by root)
2035
2036 - added a lot of scripts and macros in directory datacenter used
2037 for automatic processing
2038
2039
2040
2041 *** Version 0.9 (2005/03/23)
2042
2043 - Calibration is now done autmatically into photo-electrons like
2044 decided by the Collaboration Board
2045
2046 - Reference lines in the display can be read from resource file
2047
2048 - Interlaced calibration events can be handled by callisto
2049
2050 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2051 and applied in callisto.
2052
2053 - class MJCalibTest can be called by callisto
2054
2055 - callisto can now run with three data types: rawdata, rootdata, MC
2056
2057 - added two classes mreport/MReportStarguider.cc and
2058 mreport/MReportStarguider.h for implementing starguider-data
2059
2060 - the output of merpp-update now contains starguider information:
2061 MReportStarguider and MTimeStarguider
2062
2063 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2064 values were lower than they should. This was more visible for high
2065 energy (Size) events.
2066
2067 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2068
2069 - added a new loop to callisto to support the correct extraction of
2070 the pedestal and pedestal rms through the signal extractor
2071
2072 - added class to perform fourier tranformation of a hexagonal structure
2073 (MHexagonalFT)
2074
2075 - added class to perform fourier tranformation of a hexagonal structure
2076 in a tasklist (MHexagonalFTCalc) example: hft.C
2077
2078 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2079 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2080 small pixels, example: extendcam.C
2081
2082 - added possibility to write data to memory (TTree) using MWriteRootFile
2083
2084 - added possibility to read a TTree stored only in memory by MReadTree
2085
2086 - new classes to deal with the interleaved calibration events:
2087 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2088
2089 - implemented filters to callisto to skip calibration events
2090
2091 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2092 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2093 the slices by statistics
2094 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2095 signal extractor without randomization
2096 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2097 with the signal extractor with randomization (extraction window is
2098 randomly fixed)
2099 The three kind of pedestal is not yet implemented (for speed reasons) as
2100 long as nobody really needs it:
2101 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2102 extracted with the signal extractor with randomization
2103
2104 - callisto now finds the pulse position in the data automatically
2105
2106 - implemented data reduction in calibrated data by reducing the precision
2107 of the stored floating point values (pedestal, rms and signal) to
2108 roughly 0.5%
2109
2110 - fixed showplot to make file format conversion (eg. converting a
2111 status display stored in a root file into a postscript file) in
2112 batch mode possible:
2113 showplot -b --save-as-ps[=outfile.ps] infile.root
2114
2115 - Allow class names as part of filter rules, eg
2116 (MFSupercuts) && (MHillas.fSize>100)
2117
2118 - fixed a lot of stuff to allow all programs to process MonteCarlo
2119 camera files.
2120
2121 - enhanced possibility to debug reading of resource file
2122
2123 - MDataChain should handle priorities of operator more
2124 accurate now
2125
2126 - completely revised the container in which the signal is stored
2127 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2128 * the new implementation is faster and
2129 * needs less storage space
2130
2131 - FIRST version which can process Monte Carlos through the
2132 whole chain of programs (callisto, star, etc)
2133
2134 - implemented new image parameters for the border length of
2135 the shower image (MNewImagePar2)
2136
2137 - implemented wobble-mode in ganymed
2138
2139 - new class (MJOptimize) taking care of all optimization processes
2140
2141
2142
2143 *** Version 0.8.6 (2004/10/05)
2144
2145 - New combined signal and time extractor
2146 MExtractTimeAndChargeDigitalFilter
2147
2148 - The Report for the trigger section in the CC run summary has been
2149 updated, and now the IPRs (Individual Pixel Rates) are available.
2150
2151 - new macros for database interaction: filldotrun.C, filldotrbk.C
2152
2153 - added new program which can convert colored output which was redirected
2154 into a file back into colored text (for example to display it with
2155 more): showlog
2156
2157 - added new program to display an MStatusArray of plots (stored with
2158 MStatusDisplay) from a file: showplot
2159
2160 - Added support for Sequences (MSequence). Sequences are blocks of run
2161 files containing the same calibration and belonging to the same
2162 source
2163
2164 - Added a new task (MTaskEnv) which can be used in setup files to switch
2165 between different tasks (for example to choose a signal extractor)
2166
2167 - Implemented automatic file splitting in MWriteRootFile
2168
2169 - After image cleaning an island index is assigned to all used pixels.
2170 The index corresponds to the order of the islands in size.
2171
2172 - added a cleaning which takes signal height _and_ arrival time into
2173 account: probability cleaning (for more details see MImgCleanStd)
2174
2175 - added a cleaning which takes takes the absolute number of photons
2176 times the area ratio as cleaning level
2177 (for more details see MImgCleanStd)
2178
2179 - Changed calculation of image parameters such, that it can be done
2180 for all used pixels or the pixels with a defined island index only
2181
2182 - implemented new image parameters displaying the number of islands,
2183 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2184
2185 - event display in executable changed to support also calibrated files
2186 (done with MJCalibrateSignal)
2187
2188 - added program doing the calibration and the signal extraction
2189 and signal calibration: callisto Most part of the setup is done
2190 by a resource file: callisto.rc
2191
2192 - implemented support for pixels with negative IDs (Raw file format
2193 version 4)
2194
2195 - implemented an new option in merpp (--auto-time) to get the time
2196 range for cc and/or caco data from the run header of the raw data
2197
2198 - New star-program (star and MJStar). Taking calibrated data from
2199 callisto/MJCalibrateSignal as input. The setup is done through
2200 a resource file: star.rc
2201
2202 - Added possibility to setup the eventloop in the mars-executable
2203 Camera Display by a resource file: mars.rc
2204
2205 - The the mars-executable Camera Display can now also read
2206 calibrated data files written by callisto/MJCalibrateSignal
2207
2208 - Added a new class which can calculate the source position in
2209 the camera from a pointing model known to be correct and
2210 the pointing model used for observations (MSrcPosFromModel)
2211
2212 - added a new version of the class calculating the effective on-time
2213 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2214 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2215 MHTimeDiffTheta.
2216
2217 - added the possibility to count how often a signal is above (or
2218 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2219 can replace MHTriggerLvl0)
2220
2221 - added ore convinient ways to set the axis-titles of your histograms
2222 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2223 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2224
2225
2226
2227 *** Version 0.8.5 (2004/08/06)
2228
2229 - new Signal Extractors: MExtractFixedWindowSpline
2230 and MExtractAmplitudeSpline
2231
2232 - implementes interleave in merpp to be able to merpp parts of a file
2233
2234 - implemented force-functionality to merpp
2235
2236 - star display to display star catalogs (MAstroCatalog)
2237
2238 - star display to 'mirror' stars to the camera (MAstroCamera)
2239
2240 - implemented a new cleaning option which allows cleaning scaled with
2241 the real ratio of the rms depending on the pixel size, not only the
2242 square root of the pixelsize (MImgCleanStd, MCameraData)
2243
2244 - removed obsolete MBlind* classes
2245
2246 - Signal extractor taking the AB flag into account implemented (this makes
2247 an odd number of slices for signal extraction possible
2248 (MExtractSignalABcorr)
2249
2250 - implemented a class extracting the pedestal from the raw-data (events)
2251 itself using empty lo-gain (MpedCalcFromLoGain)
2252
2253 - Added mean values to MPedPhotCam
2254
2255 - Added Makefile for Darwin (this OS is NOT officially supported!)
2256
2257
2258
2259 *** Version 0.8.4 (2004/04/19)
2260
2261 - new fast arrival time extractor using cubic splines:
2262 MExtractTimeFastSpline
2263
2264 - implementes multi-argument support in MDataChain
2265 ("pow(a, b)")
2266
2267 - implemented double reference support in MDataChain
2268 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2269
2270 - added support in MF for expressiond like
2271 "MHillas.fWidth<2*<MHillas.fLength"
2272
2273 - MDataChain is now able to support variables like [0], [1], ...
2274 which can be used in fit functions as parameters. The interface
2275 is implemented through the new virtual function
2276 MParContainer::SetVariables
2277
2278 - added new class MArrivalTimeCam/MArrivalTimePix:
2279 Storage containers to hold the ArrivalTime of the camera/pixel
2280
2281 - added new classes for the calibration of relative arrival times:
2282 MCalibrationRelTimePix and MCalibrationRelTimeCam
2283
2284 - added new classes to extract the signal of the blind pixel and the
2285 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2286
2287 - added new classes for the bad-pixels treatment (MBadPixels*)
2288 which are more powerfull than the old ones (MBlindPixel*)
2289 and will replace them.
2290
2291 - added filter against cosmics: MFCosmics
2292
2293 - added new class MArrivalTimeCalc2:
2294 Calculates the arrival time as the signal weighted mean of the time
2295 slices in the maximum window
2296
2297 - added a new macro call pointspreadfucntion.C that fits with a 2D
2298 gaussian the DC spot for an star. It gives you the RMS of
2299 the PSF and the center of the star, very useful for misspointing
2300 studies.
2301
2302 - added support for multi-telescope camera files. Added classes
2303 MStereoCalc and MStereoPar, classes to calculate and store shower
2304 parameters calculated from the data of two telescopes, for the MC
2305 studies regarding the MAGIC clone.
2306
2307 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2308 MC data calibrated in photons instead of ADC counts.
2309
2310 - added three macros to show the calibration and analysis chain of
2311 MC data. The macro starmc.C does both calibration and analysis, producing
2312 an output containing Hillas parameters for each event. The macro
2313 mccalibrate.C does just the calibration and writes out a file containing
2314 pixel information in photons instead of FADC data. The macro starmc2.C
2315 reads in such a file and produces an output with Hillas parameters.
2316
2317 - added MPedPhotCalc to compute pedestals in units of photons, see
2318 macro pedphotcalc.C
2319
2320 - added all class to perform the calibration, see macro calibration.C
2321
2322 - added class MFFT to perform Fast Fourier Transforms
2323
2324 - added class MSimulatedAnnealing to perform simulated annealing
2325 minimizations
2326
2327 - added new macro bootcampstandardanalysis.C which holds the skeleton
2328 of the analysis chain discussed in the december bootcamp.
2329
2330 - added support for DAQ raw data file format V2
2331
2332 - implemented an arbitrary time stamp for the events from raw-data
2333 files with file version<3. It is calculated from the run number,
2334 the date of start and the FADC clock tick from the first module
2335
2336 - implemented the correct decoding of the event time-stamp
2337 coming from the DAQ for raw-data files with file-version>2
2338
2339 - added a new classes storing the pedestals in units of photons:
2340 MPedPhotPix, MPedPhotCam
2341
2342 - added support for DC current files from the camera control
2343
2344 - added support for start- and stop-time when merpping report files
2345
2346 - added MReportCC storing the weather data from the CC-REPORT
2347
2348 - added class to fill trainings and test matrices (MTFillMatrix)
2349
2350 - added a filter performing a software trigger (MFSoftwareTrigger)
2351
2352 - Added classes to perform parts of the standard analysis (Jobs):
2353 + MJPedestals
2354 + MJCalibration
2355 + MJExtractSignal
2356 Note: All of them are preliminary!
2357
2358 - Added Iterator to iterate over files giving only the run-number
2359
2360 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2361 the evolution of a sector vs time
2362
2363
2364
2365 *** Version 0.8.3 (2003/12/05)
2366
2367 - adapted Random Forest classes to allow the use with MC
2368 multi-telescope files which can be produced with the coming
2369 camera version 0.7.
2370
2371 - added classes to read and interprete central control report files
2372 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2373
2374 - enhanced merpp (the executable) to support .raw and .rep files.
2375
2376 - added classes for light calibration (MCalibration* and
2377 MHCalibration*) by Markus Gaug. Further work has to be and will
2378 be done soon.
2379
2380 - Added a preliminary 'synchronizer' (MReadReports) which will
2381 replace MReadMarsFile as soon as it is finished.
2382
2383 - Added a tutorial macro demonstrating how report files are merpped
2384 and how they can be read from the root file in the correct order
2385 of time (readrep.C)
2386
2387 - Added a generalized histogram (similar to MH3) called MVsTime
2388 which allows to plot variables (or rules - MDataChain - of
2389 variables) vs time. For an example have a look at tempvstime.C.
2390
2391 - Changed the name of the event trees:
2392 + Events --> Events
2393 + PedEvents --> Pedestals
2394 + CalEvents --> Calibration
2395
2396 - changed name of MTime in the event trees from MRawEvtTime to MTime
2397
2398 - added displaying the sector indices to the mars event display
2399
2400 - Magic Online Analysis (MOnA) implemented in a first version
2401 (see mona.cc, MOnlineDump and MOnlineDisplay)
2402
2403 - added classes to calculate event rate
2404 (preliminary: MEventRateCalc, MEventRate)
2405
2406 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2407
2408 - added classes dealing with the telescope pointing position (MPointing*)
2409
2410 - implemented the 'final' Mars time stamp based on some experiences with
2411 the new 'Synchonizer'
2412
2413
2414
2415 *** Version 0.8.2 (2003/11/10)
2416
2417 - accelerated standard analysis by a factor of 6-8 ...
2418 + doing precalculations in MGeomCam for the pixel area ratio
2419 + creating a look up table for the single pixels in MCerPhotEvt
2420
2421 - added task to calculates weights in case you want to 'change'
2422 the energy spectrum of a monte carlo file
2423 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2424
2425 - added a new executable star which implements the
2426 star.C macro as precompiled executable. Currently a flexible
2427 setup is not possible, but a 'input card' setup will follow.
2428
2429 - Starting to implement Multi-Telescope-Support based on the
2430 upcomming camera version 0.7. The base for a general support
2431 is implemented and the star-functionality is proven to work.
2432
2433 - Replaced Event-Display in and Camera-Display in the Mars GUI
2434 executable by a more convinient display base on MStatusDisplay.
2435
2436 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2437
2438
2439
2440 *** Version 0.8.1 (2003/10/20)
2441
2442 - added signal subtraction for pure on data by means of fitting
2443 the background in the off region or by performing a combined
2444 signal/background fit. Provides necessary histograms for
2445 obtaining energy spectra and a light curve.
2446
2447 - added classes to perform and study the selection of the
2448 2nd Level Trigger on MC data (example in triglvl2.C macro)
2449
2450 - added pedestal calculation
2451
2452 - implemented "democratic cleaning" (tail cut value proportional
2453 to pixel area) according to Wolfgang's suggestion.
2454
2455 - added Sigmabar treatment (calculation and basic histogramming)
2456
2457 - added basic routines to apply padding
2458
2459 - added first implementation of MARS-based source visibility plotter
2460 (needs to be linked against slalib, preliminary version)
2461
2462 - enhanced functionality of data chains: random numbers, conversion
2463 functions and access to MHMatrix objects
2464
2465 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2466 numbers under certain circumstances (runs with 0 events included)
2467
2468 - fixed a bug in the general filter MF (didn't work on some systems
2469 at all)
2470
2471 - fixed a bug in chaining files, which caused the analysis to crash or
2472 ignore files
2473
2474 - implemented more geometry classes describing the parameters used
2475 to simulate the PMT camera
2476
2477 - added new Monte Carlo classes containing the setup of the different
2478 programs in the MC chain.
2479
2480 - added a (preliminary) general task to evaluate chi-square of a given
2481 parameter in an eventloop.
2482
2483 - first implementation of a container describing the observatory
2484 location (Long, Lat, etc)
2485
2486 - added Random Forest - method for g/h-separation
2487
2488 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2489 (this means, that it is compiling, but not yet fully tested)
2490
2491 - added a new status display which can show the present status
2492 of histograms while an eventloop is running (MStatusDisplay,
2493 an example can be found at status.C)
2494
2495 - reorganized directories:
2496 classes describing the image --> mimage
2497 classes containing Monte Carlo Histograms --> mhistmc
2498 classes for Random Forest method --> mranforest
2499
2500 - added (event-)weights to fill histograms
2501
2502 - colors in logging output to screen
2503
2504 - changes to the Image Parameter declaration:
2505 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2506 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2507 + MHillasExt now derives from MParContainer instead of MHillas
2508 --> Files written with the old definition are more or less unreadable
2509
2510 - reading of reflector files
2511
2512 - display data from reflector files in the camera
2513
2514 - implemented currents (and display them in the camera)
2515
2516 - logarithmic scale in camera
2517
2518 - added class to iterate through directory contents (MDirIter)
2519
2520
2521
2522 *** Version 0.8 (2002/11/18)
2523
2524 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2525
2526 - corrected 48(!) wrong entries in the Next Neighbor table of the
2527 Magic Camera (all in the inner part of the outer ring, mostly
2528 missing a single NN)
2529
2530 - Fixed a bug in the table describing the Next Neighbours of the
2531 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2532 have any neighbour)
2533
2534 - changed trigrate.C: now it calculates the pure NSB triggers from
2535 a camera file (generated with no showers), so there is no need
2536 to introduce them by hand in the BgR array (for more details
2537 please ask Abelardo)
2538
2539 - added MHHadronness (and MHadronness) as a general facility to evaluate
2540 the quality of a gamma-hadron seperation method
2541
2542 - changed MWriteAsciiFile to accept rules (MDataChain)
2543
2544 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2545 must be replaced by calles to MWriteAsciiFile::AddColumn and
2546 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2547 changed.
2548
2549 - Implemented generalized event-matrices (one row per event)
2550 (MHMatrix)
2551
2552 - implemented the one dimensional composite probabilities
2553 (MHCompProb, MCompProbCalc, comprob.C)
2554
2555 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2556 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2557
2558 - Added a camera display displaying the pixel numbers to the
2559 event display gui.
2560
2561 - Added Monte Carlo Informations to event display gui
2562
2563 - Changed the camera display to display the pixel numbering
2564
2565 - Added three buttons to the camera display to change the palette
2566
2567 - Added the number of used and core pixels after image cleaning
2568 to MHillas
2569
2570 - Changed the algorithm used in MHillas according to TDAS 02-03
2571
2572 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2573
2574 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2575
2576 - Added fCosDeltaAlpha to MHillasSrc
2577
2578 - The numbers of photons used to calculate fConc and fConc1 in
2579 MHillasExt are now scaled with the pixel size, so that one get
2580 a four times smaller value for the bigger pixels in the outer ring.
2581
2582 - added new task to smooth the camera contents (MCameraSmooth)
2583
2584 - added possibility to use interpolated pixel values for blind pixels
2585 instead of removing it completely from the analysis
2586
2587 - Implemented the possibility to save the whole eventloop with
2588 its setup to a file. This information can be read and from
2589 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2590 and MEvtLoop::MakeMacro. If you find something not working, please
2591 report - this stuff is still in a beta phase.
2592
2593 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2594 file having crab starfield, but also for all following files - fixed
2595
2596 - MTaskList::PrintStatistics can now be instructud to print also the
2597 title, too: use PrintStatistics(0, kTRUE)
2598
2599 - Changed the image cleaning so that pixels with to many 'used'
2600 neighbors are left used (to get rid of 'holes' in events)
2601
2602 - Introduced more output to the camera displays
2603
2604 - Added an array of histograms (eg one hist per run), MHArray
2605
2606 - Added a _preliminary_ version of the reader for CT1 PreProc files
2607 (MCT1ReadPreProc)
2608
2609 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2610 (thanks to Raquel)
2611
2612 - added the first energy estimator (MEnergyEstParam, estimate.C,
2613 estfit.C) using a parametrization
2614
2615 - Added some new Monte Carlo paremeter containers used to store
2616 setup information from the MC chain (MMcConfigRunHeader,
2617 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2618
2619
2620
2621 *** Version 0.7 (2002/04/30)
2622
2623 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2624 the pedestal mean value was saved incorrectly. For files from
2625 this versions we substract 0.5 from the pedestal mean.
2626 WARNING: This may effect your results, so don't wonder...
2627
2628 - First implementation of an algorithm using only triggered events
2629 for the collection area calculation
2630
2631 - Ascii Output can now also be used for parameter containers which
2632 doesn't overload MParCointainer::AsciiWrite
2633
2634 - The Ascii Output is now also capable of writing single data members
2635 of one container
2636
2637 - You are now able to change the order of the values written to the
2638 ascii file
2639
2640 - You can now specify a conversion factor for each data member written
2641 to an ascii file. This may be usefull to change the units of the
2642 data member (eg. degrees instead of millimeters in case of the
2643 hillas parameters)
2644
2645 - Replaced old MHillas by a new structure which allows you to extend
2646 the parameters stored in MHillas very easily:
2647 see MHillas and MHillasExt
2648
2649 - Added classes to handle source dependancy of image parameters:
2650 see MHillasSrc
2651
2652 - Added container (MBinning) to have a standard input for the binning
2653 in different histograms (eg. the Energy bins should be the same in
2654 all histograms)
2655
2656 - Changed Hillas histograms from mm to deg
2657
2658 - Added the flexible binning to the hillas histograms
2659
2660 - Added a filter for the alpha parameter (MFAlpha)
2661
2662 - It is now possible to write single data members of a class object to
2663 an output stream instead of the whole container only
2664
2665 - Added a generalized filter for a data member:
2666 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2667
2668 - Added a generalized Filter parser for more difficult filter rules
2669 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2670
2671 - Added new Monte Carlo histograms:
2672 MHMcEnergyImpact and MHMcEfficiency
2673
2674 - Added many new histograms needed for the flux calculation.
2675
2676 - Added a generalized histograms which can fill and show up to three
2677 data members in either a one-, two- or three-dimensional histogram, eg:
2678 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2679
2680 - Added:
2681 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2682 * calculation of <Theta> as a function of time (MHThetabarTime)
2683 they are needed in the flux calculation in
2684 order to select for a given bin in Theta (or time) the appropriate
2685 effective collection area, which is assumed to be given as a function
2686 of Theta and the true energy
2687
2688 - Added calculation of the migration matrix in the energy
2689 (MHMcEnergyMigration):
2690 the migration matrix describes the migration from the true (E_true)
2691 to the estimated energy (E_est); it is needed to determine the
2692 distribution of E_true from the measured distribution of E_est
2693 by unfolding
2694
2695 - changed the color palette in the camera display to DeapSea.
2696
2697
2698
2699 *** Version 0.6 (2002/01/15)
2700
2701 - Introduce the option of disable pixels (MBlindPixels and
2702 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2703 able to deal with Star Field NSB.
2704
2705 - Fixed a bug in the pedestals substraction
2706
2707 - Introduced verbosity levels
2708
2709 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2710
2711 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2712 work correctly (thanks to Abelardo)
2713
2714 - Introduced correct treatment of the diffuse Night Sky Background
2715 and NSB (MMcPedestalNSB)
2716
2717 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2718
2719 - Introduced MMcRunHeaders which contains monte carlo run informations
2720
2721 - Added a 'Print'-Task (MPrint) which calls the Print function
2722 of a parameter container for each event
2723
2724 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2725
2726 - changes to be more efficient with root 3.02/06
2727
2728 - root 3.02/06 fixes:
2729 + the memory leak when reading MRawEvtData
2730 + loosing more time than necessary to update the progress bar
2731
2732 - MWriteAsciiFile is now capable of writing more than one container
2733 in a line. For example: To be able to write Monte Carlo and
2734 Hillas values (energy and alpha) in one line.
2735
2736
2737
2738 *** Version 0.5 (2001/11/06)
2739
2740 - Added new GUI functionality (Analysis)
2741
2742 - Added a camera display to be able to display events in the camera
2743 together with the calculated hillas ellipse
2744
2745 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2746 object at any state of the analysis, so that the output are several
2747 states
2748
2749 - Fixed a bug in the collection area error calculation
2750 (Thanks to Ciro and Abelardo)
2751
2752 - Fixed a bug which causes merpp to crash in some environments
2753
2754 - Implemented auto enabling scheme for Branches to speed up reading
2755 a lot (see MReadTree and MTask)
2756
2757 - Fixed a bug in the Histogram classes which caused histograms to
2758 be written to a file by MWriteRootFile without request
2759
2760 - changed the object I/O from the old stylish root I/O to the new
2761 'auto evolution scheme' This was done only for classes which are not
2762 yet used in Monte Carlo files, so that these files are still readable.
2763
2764 - Added support for a progress bar in MEvtLoop and MReadTree
2765 (see the Analysis Window in Mars for an example)
2766
2767 - Fixed a bug in the package creation which disturbed the conversion
2768 between a mars version unpacked from a tar file and the repository.
2769
2770 - Changed the code to writer merpped (converted into root format)
2771 raw files, to get faster (around 10%)
2772
2773
2774
2775 *** Version 0.4 (2001/09/20)
2776
2777 - This release is made to compile on a root version >= 3.00
2778
2779 - Fixed a bug which causes MReadTree to read the first file only
2780
2781 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2782
2783 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2784
2785 - Added a task to write several container to a root file (MWriteRootFile)
2786
2787 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2788
2789 - Added calculation of the collection area (MMcCollectionAreaCalc)
2790
2791 - fixed some bugs in the Hillas calculation
2792
2793 - added filters to be able to control the task execution dependent on
2794 a parameter (for example: the number of level 1 triggers in a MC-file)
2795
2796
2797
2798 *** Version 0.3 (2001/04/23)
2799
2800 - Many demo macros added
2801
2802 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2803
2804 - Hillas Calculation added
2805
2806 - Standard image cleaning available
2807
2808 - MReadTree is now able to handle more than one file
2809 (Remark: of the same structure)
2810
2811 - Now we are able to display events in a first version of the
2812 Camera event display. To do this we must run the macro
2813 "macros/readCT1.C" to read data from CT1.
2814
2815
2816
2817 *** Version 0.2 (2001/01/24)
2818
2819 - First Implementation of a Gui to read the raw data. Start the
2820 gui with the command mars.
2821
2822
2823
2824 *** Version 0.1 (2000/12/20)
2825
2826 - First official release 0.1