source: trunk/MagicSoft/Mars/NEWS@ 8947

Last change on this file since 8947 was 8947, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 117.6 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;Database
6
7 * introduced average temperature and wind speed from star-files
8
9 * introduced the ratio of accepted calibration events in the
10 calibration run
11
12 * introduced the average rates of the different trigger pattern,
13 e.g. the rate of pedestal and calibration events, from the signal-file
14
15 ;general
16
17 * fixed GroupBy options in plot*.C macros
18
19 * only display KVA points (not the Tuorla points) in plotoptical.C
20
21 * all programs now allow to add resources to the ones from the resource
22 file or overwrite them from the command line. This can be done like this
23 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
24 if something seems to be wrong you can debug what the program is doing
25 using the option --debug-env=3
26
27 * increased the diversity of debug levels. That also means that with -v3
28 you get now less output, i.e. only the output which is important for
29 an analysis. To get more output which helps for debugging try 4, 5 and 6.
30
31 * fixed a problem in the task synchronizing the reading of the reports
32 and the data stream. The effect was that in some circumstances the last
33 events of some trees could have been skipped. Since this is only a
34 very tiny part of the data no severe effect to your analysis results
35 is expected (an exception might be very short, i.e. singel runs,
36 datasets).
37
38 * Dataset file now allow to include the sequence file directly within
39 the dataset file and also allow to exclude single runs from the dataset.
40 (for more details see Class reference of MDataSet)
41
42 * Sequence files now allow for excluding runs from the analysis
43 (for more details see Class reference of MSequence)
44
45 * added code to process the sum-trigger flag
46
47 * the histogram classes MH3 and MHn now support profile histograms
48
49 * the histogram classes MH3 and MHn now support labels at the axis
50
51 * the Random Forest Train-classes (MJTRain*) now store the used datasets
52 in the output file
53
54 * the MFMagicCuts have a new option to allow a linear area cut (for
55 special studies)
56
57 * The liniking of the shared object is now done into a file defined
58 by 'mktemp'. This should be a local file system which accelerates
59 liniking a lot.
60
61 * The code has been prepared for compilation with root 5.18/00d
62
63 * The MHEnergyEst histogram now shows the distribution of
64 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
65 and (Eest-Emc)/Emc vs Emc.
66
67 * fixed mars (event display) for merpped raw-data and MC data
68
69 ;merpp
70
71 * Implemented cc file version 2008-20-02/0
72
73 * Implemented raw data format 11 (the most important change, except
74 from plenty of changes in the format definition, is the addition
75 of the file-number in the header) If nobody makes a mistake this
76 format should have the advantage that it is by definition forward
77 compatible, so old programs will be able to read newer formats.
78
79 * Added Pyrometer information to output (stored in a new Tree
80 Pyrometer, needs a complete new merpp, i.e. new calibration)
81
82 ;callisto
83
84 * in the pedestal processing now at least 50 processed events are
85 required for succeeding.
86
87 * the signal and calib files now contain also the sequence information
88
89 * the two MPedestalCam in the calib file now have proper names
90 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
91
92 * Both pedestal cams now conatain the number of events processed
93
94 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
95 i.e. for the extraction of the calibration pulses basically the average
96 over all events of the first slice instead of all slices was used.
97 Since pedestal and calibration constants are continously recalculated
98 this only effected the very first events of every sequence.
99
100 * For the extraction of the position of the maximum sample now the
101 extraction range is set automatically to the extraction window,
102 before the whole accessible range was used.
103
104 * If the number of samples in the events and the number of samples
105 in the run-header disagrees now an error is raised (this can
106 happen in not well simulated Monte Carlo files)
107
108 * In the case of MUX-data pedestal events with the lvl1 trigger flag
109 could survive into the pedestal calculation -- fixed.
110
111 * Tab "TrigPat" added showing the distribution of the trigger pattern
112 as found in the run-files (normalized with the run length)
113
114 * The selection of events from the trigger pattern has been improved.
115 If the trigger pattern is corrupted events won't pass anymore.
116
117 * Added a new command line option --dev-null to suppress output of
118 Y-files (this is useful for test cases)
119
120 * added a new tab "CalPos" showing the arrival time of extracted
121 interleaved calibration events
122
123 ;star
124
125 * the star file now contains also the sequence information
126
127 * Added a new command line option --dev-null to suppress output of
128 I-files (this is useful for test cases)
129
130 * Tab "Rate" added showing the distribution of the trigger pattern
131 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
132 the Y-files (normalized with the run length)
133
134 * The effective on-time calculation doesn't use events with only
135 sum-trigger anymore
136
137 * The data in the MHWeather tab has been reorganized. The never
138 working solar radiation has been removed and the data from
139 the pyrometer (cloudiness, air and sky temperature) is
140 displayed in addition.
141
142 ;ganymed/sponde
143
144 * Now data points are even shown correctly if they have error bars larger
145 than one sigma. Points with null or negative significances are omitted.
146
147 * DrawNicePlot now allows to set a projection range
148
149 * Updates pointing models. One is applied after the implementation
150 of the new LUTS in August, the other one is applied after the
151 next major change of the pointing model in October. Note that
152 these models are preliminary and give wrong results below Zd=65deg
153
154 ;sponde
155
156 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
157
158 * a new option "--force-runtime" is available. In case of very short
159 datasets (for light-curves) which are in the order of a few
160 minutes the calculated effective on-time is not very acurate because
161 it is quantizised in th eorder of a minute. Therefore you can switch
162 to using the real run-time instead (remakrt: this ignores any
163 dead-time!)
164
165 * a more analytical way is used to "fill" Monte Carlos into regions
166 of impact parameters which have not been simulated because the
167 trigger efficiency is assumed to be 0.
168
169 * estimated sensitivity curves for hi and lo zenith angles are shown
170 scaled to the correct observation time and collection area
171
172 * the Monte Carlo events after cuts are now written to the output file
173 if an output file given
174
175
176
177 *** Version 2.0 (2007/09/03)
178
179 - database: the position used for the pulse pos check was missing
180 in the callisto output and could thus not be filled into the DB.
181 Also the old values seemed not exactly the PulsePos used for
182 teh check.
183
184 - general: Resource file now allow an Include-Resource, i.e. you can
185 read a resource file with default settings, include it in your
186 resource file and overwrite the settings in your file. More than
187 one include file is allowed. Inclusions can be iterative.
188 Include: mydefaults.rc yourdefaults.rc
189 The resources in the first file have higher priority than the
190 second file.
191
192 - general: Now the output files (calib*.root, etc) also contain the
193 resource file (to check it open it in the TBrowser and choose Print()
194 from the context menu)
195
196 - general: Dataset files now allow to overwrite the default path
197 to search for sequence and data files. Note, that the program
198 option and individual resources will overwrite it. For example:
199 SequencePath: /magic/montecarlo/sequences
200 DataPath: /magic/montecarlo/star
201
202 - general: Fixed a problem with variables in MDataPhrase. It seems
203 that only optimdisp (didn't work) was effected.
204
205 - general: Some improvements to the optim and train processing. For
206 example the ststud window now got a proper title.
207
208 - general: The "Status Display: " was removed from the window title
209 within an Eventloop.
210
211 - general: added a new flexible histogram-class (MHn) which can be used
212 for example in testing after optimizations or training to produce
213 user defined histograms.
214
215 - general: The Random Forest now allows attaching an evaluation
216 function which is applied to its output. This allows to train
217 on whatever you like (eg. train on log10(energy), but return
218 energy)
219
220 - general: The Random Forest training of energy (trainenergy.c) and
221 disp (traindisp.C) has been improved by more graphical output to
222 judge the result.
223
224 - general: The training of energy (trainenergy.C) has been improved
225 a lot by training on a different quantity than energy. It gives
226 a result which is highly independant of the source spectrum
227 and shows lower bias than all other options.
228
229 - general: Dataset files are allowed to contain collections of
230 datasets. For more details see the class reference of MDataSet.
231
232 - general: The default WobbleMode in a datset file now (if not
233 overwritten) is "auto", i.e. wobble mode is set if the dataset
234 doesn't contain off-sequences.
235
236 - merpp: Merpp can read file format version 9 now. Please realize
237 that for file format version 9 the extraction range is different
238 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
239 the first and last 15 slices have been removed from all MUX data.
240
241 - mars: Similar to writing movies you can now select events which
242 should be displayed in your display. Therefore add the following
243 lines to your mars.rc:
244 MFEvtNumber.FileName: ganymed00223552.root
245 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
246 The input file can be a ganymed-file after (ganymed*.root) or
247 before (ganymed*-summary.root) file. For example to select all events
248 from your on sample after cuts (excluding the ThetaSq cut) use
249 MFEvtNumber.Selector: DataType.fVal>0.5
250 To show all events from your on-sample after quality cuts
251 use the summary file instead.
252
253 - mars: new ways to call mars are implemented. Instead
254 of calling
255 mars filename.root
256 you can now also use
257 mars sequence.txt
258 or
259 mars sequence.txt inputpath
260 or replace sequence.txt by the sequence number if the default
261 sequence file should be used.
262
263 - mars: The default size has been increased
264
265 - mars: There are two new heckboxes which allow to switch off
266 the calculated image parameters
267
268 - callisto: was broken for MCs... fixed.
269
270 - callisto: improved calculation of spline coefficients a lot. This
271 leads to a further improvement of the event rate calibrating MUX
272 data of about 15% (175evt/s instead of 150evt/s)
273
274 - callisto: finally the raw data we read is now real 16bit (with
275 10bit precision) for MUX data and not a stripped 8bit number
276 anymore. Due to scaling of the numbers (without precision loss
277 into an [0-256[ range, the final numbers for pedestal, pedestalrms
278 and extacted signal don't change. However, at all places where
279 raw data is directly accessed (eg. saturation and variation
280 limits in the signal- and pedestal-extraction) the numbers
281 refer still to the data's 16bit range.
282
283 - callisto: The maximum arrival time difference used in the bad
284 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
285 for both, old FADC and MUX-FADC, data.
286
287 - callisto: Be aware that callisto is now calibrating the arrival time
288 in nanoseconds rather than time slices. Also all following tasks
289 have been changed to assume ns units now. If you star data
290 calibrated with an older version it might be necessary to adapt
291 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
292 to obtain optimal results. The plot in the PulsePos tab
293 will now be in ns, too. This might also mean that the Muon
294 analysis in star might not work as perfect as expected as long
295 as old files read in.
296
297 - callisto: The calibration constants of earlier updates got lost
298 somehow. All constants have been updated.
299
300 - star: The PSF is now determined from the profile of the ArcWidth
301 instead of arcwidth/radius. The old way gave to much weight
302 to the bins with low statistics. The reference lines have been
303 updated.
304
305 - star: For speed reasons events suitable for the muon analysis
306 are now also preselected by fConcCOG<0.1 which seems to be a very
307 good preselector for muons.
308
309 - star: is now calculating a new timing parameter the Slope along
310 the major and minor axis of the shower. Therefore a numerical
311 solution of a line-fit is used. To use MHillasExt.fSlopeLong
312 and MHillasExt.fSlopeTrans don't forget to multiply it with
313 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
314
315 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
316 have been removed from MNewImagePar. They have never been good for
317 anything.
318
319 - star: Implemented a new recursive algorithm which is supposed to be
320 faster. Also implemented new cleaning oiptions, which are:
321 + CleanLevel0:
322 The cleaning level above single core pixels can be kept
323 + KeepIsolatedPixels:
324 Define whether single core pixels should be kept
325 + TimeLevel1:
326 The coincidence window in nanoseconds to single used neighbors
327 + TimeLevel2:
328 The coincidence window in nanoseconds to two used neighbors
329 + PostCleanType:
330 MOde in which a time dependent post cleaning should be applied
331 0: No post cleaning
332 1: Require for each used pixels at least one used neighbor
333 within a time-window of CleanLevel1
334 2: Require for each used pixels at least two used neighbor
335 within a time-window of CleanLevel2
336 3: Require first two and second one used neighbor
337 within a time-window of CleanLevel1 and fCleanLevel2
338 respectively
339 + RecoverIsolatedPixels:
340 - recoveres isolated core pixels if they have a used neighbor
341
342 - mars/star: The new default cleaning is:
343 + CleanLevel1: 6.0
344 + CleanLevel2: 3.0
345 + CleanTime1: 1.75
346 + CleanTime2: 1.75
347 + PostCleanType: 3
348
349 - star/ganymed: The old spark-cuts have been replaced by new ones.
350 These new spark cuts have been cross checked with the sequences
351 84720 (before splitter), 101041 (after splitter) and 223539 (new
352 FADCs). In all cases they seperate pretty well, but of course not
353 perfect. Monte Carlos have suggested to tighten the cuts a little
354 bit further at low sizes. This has been done.
355
356 - ganymed: IMPORTANT - The spark cuts have been changed to match
357 all available data more or less well. This might mean that for
358 YOUR data there are still sparks visible.
359 Whenever you do an analysis you have to make sure that NO sparks
360 survive your cuts!
361
362 - ganymed: The old hadronness and size cuts have gotten new indices
363 (10, 11). The old indices 8 and 9 now mean an additional condition
364 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
365 If you want to switch off this cut just move the line far away enough,
366 e.g. by setting c[9] to -500. Please update your ganymed.rc files
367 accordingly!
368 The unit of c[9] is deg. It is the dist at which your cut will
369 cross the slope==0. The unit of the slope is ns/deg. So if
370 you readin files calibrated with an older Mars-version you
371 have to adapt the default value for c[9] to the FADCs:
372 - Multiply by two for the MUX FADCs (run number > 200.000)
373 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
374 - Multiply by 42 for the meaning of life (run number = 200.000)
375
376 - ganymed: The old Cut0 is now called CutQ and is calculated before
377 the source position is caluclated. If you need a quality cut
378 including source dependant data (be very carefull with this!)
379 you have to use Cut0 instead.
380
381 - ganymed: now properly supports three off regions in wobble mode.
382 It will be the default from now on in ganymed_wobble.rc. To change
383 the number of off-regions use
384 NumOffSourcePositions: 1
385 in your ganymed.rc. Also by default no off-theta cut will be done
386 anymore so that you will get a background level higher than the
387 signal level in your ThetaSq plot for ThetaSq>0.2.
388 Due to this be carefull changing the scaling mode away from
389 "None". You will underestimate your signal if your scale interval
390 is not properly set.
391 (Rem: ThetaSqN is no longer needed)
392
393 - ganymed: is now storing the events of all (on- and off-)
394 source positions even in the case of more than one off-source
395 position. This should allow sponde to work properly and the
396 energy estimation is done correctly in all cases (without any
397 "nearest position" trick)
398
399 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
400 with a real pointing model for the starguider is done, calibrated
401 with more than thousand tpoints taken from this date on.
402
403 - ganymed: was broken for Wobble-MCs... fixed.
404
405 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
406 has changed. Note that your old ganymed.rc will be incompatible
407 with the new algorithms! Please check the ganymed.rc files and
408 the class description of MFMagicCuts for more information.
409 It is recommended at the moment to use identical Disp-Parametrizations
410 for on/off- and wobble-mode. If cuts are optimized only
411 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
412 should be optimized. All other values should be kept as they are.
413 If you want to do an anylsis without timing a parameters, you can
414 switch off the timing cuts by seeting parameter 7 to a very small
415 value (eg. -99). To remove the slope parameter from the disp
416 paremtrization set parameter 8 to 0.
417
418 - ganymed: The distribution of observation time versus zenith
419 angle is now shown for off- AND on-data.
420
421 - ganymed: The contents of the source position plot are no longer
422 averaged, thus a lot of (fake) events between the two wobble
423 positions have disappeared.
424
425 - ganymed: There is a new tab "CutT" it contains the VsSize plots
426 with the CutT, whihc is defined in ganymed.rc, applied. It
427 is resonable to use your theta-cut for it, to see if there is
428 something strange (sparks!) in your signal-region.
429
430 - ganymed: To choose a dataset from a collection in a dataset file
431 use the new command line option "--dataset=12345"
432
433 - optim, sponde: should now properly support three off-regions.
434 Just produce your ganymed summary files with three off-regions.
435 optim and sponde will automatically get all off events from
436 all off-regions from this file. Please do not forget to
437 set the scaling in optimwobble.C properly:
438 fit.SetScaleUser(1./3);
439 it is not yet read in automatically (will follow soon).
440 In the case of fixed Scale you can also use
441 cuts.SetThetaCut(MFMagicCuts::kOn);
442 no off-cut needed.
443 Be carefull in case of three off-regions when switching on
444 scale mode. Make sure that the scale interval is set correctly.
445
446 - sponde: sponde.rc and sponde_onoff.rc are now idetical
447
448 - sponde: the resouce files have been rewritten with a lot of
449 comments and a well working parametrization for an energy estimator
450
451 - sponde: In the estimated energy versus monte carlo energy plot the
452 contents where exchanged.... fixed.
453
454 - sponde: the so called "accurate"-mode has been removed. It didn't
455 give any improvement in accuracy, only decreased execution speed.
456
457 - sponde: the so called "simple"-mode has been removed. It didn't
458 give any improvement in simple.
459
460 - sponde: the so called "refill"-mode has been removed. It was anyhow
461 not implemented.
462
463 - sponde: now checks whether the theta distribution of your on-data
464 and the theta-distribution of your Monte Carlo sample (after
465 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
466 sample is incomplete) execution is stopped. Execution can be forced
467 using the new option --force-theta. Use this option with care!
468
469 - sponde: Proper collection areas can now be constructed also from
470 Monte Carlo samples generated with different maximum impact
471 parameters. Note that in previous version you neither got
472 a warning or failure, nor was there any obvious sign that the
473 collection area was overestimated due to usage of files with
474 different maximum impact parameters.
475
476 - sponde: If MC files with different lower energy limits are used
477 the primary MC spectrum is artificially completed down to the
478 lowest energy used at all. WARNING: that this gives correct
479 collection areas ONLY if none of the events in this region would
480 survive your cuts at all.
481
482 - sponde: the output file now contains more information about
483 the spectrum (eg. the full 2D collection area histogram).
484 Note, that this information can only be written to the file
485 if it is stored automatically via command line argument.
486 If you only store the status display from within the display
487 the information is lost.
488
489 - sponde: added a new tab "Disp". It shows the residual of the disp
490 (Disp-Dist) versus several parameters and it is meant to judge the
491 quality of the disp estimator. In the ideal case the residual is zero
492 and doesn't depend on any variable. The tab is displayed after
493 CutQ and Cut0.
494
495 - sponde: added a new tab "Energy". It shows the residual of the
496 energy (lg(estimated energy)-lg(monte carlo energy)) versus
497 several parameters and it is meant to judge the quality of the
498 energy estimator. In the ideal case the residual is zero
499 and doesn't depend on any variable. In reality even a good estimator
500 can show residuals versus Monte Carlo energy. The tab is displayed
501 after all cuts.
502
503 - sponde: added a new tab "EventDist" showing the unweighted real
504 absolute number of events of your sample after cuts. This tells
505 you how many events with this energy you had in your MC files.
506 The same information you get from the error bars of the weighted
507 histograms, but this is less intuitive.
508
509 - sponde: The spectrum plots now show the crab- and 1553-spectrum
510 for comparison. It is not meant to show these curves in
511 publications, they are only for production.
512
513 - sponde: The OriginalMC tree with the events produced by corsika
514 is now processed only once
515
516 - sponde: Finally fixed most annoying bug, which has effected the
517 last bin of the collection area. It was the problem that binnings
518 of root histograms are from 1 to n (included) but there was a C-like
519 loop in sponde from 0 to n (excluded). Now the loop also includes
520 correctly under- and overflow-bins. The worse thing with this is,
521 that for the events in the highest bin not only the bin-content
522 was wrong, but also the weights applied to these events, which could
523 in pricipal effect also other parts of the distribution (eg. due
524 to energy estimation). Fortunately it effected only a few events
525 in most cases.
526
527
528
529 *** Version 1.2 (2007/05/14)
530
531 - database: The database now has two new values Unsuitable50 and
532 Unsuitable01. They express the number of pixels which are
533 unsuitable for more than 50%, respectively more than 1%, of
534 all calibrated event. It is a more accurate number than the
535 previously used numbers, because they only take the first
536 calibration (ignoring the interleaved calibrations) into account.
537
538 - database: The database now has two other new values UnsuitableMax and
539 DeadMax. They express the maximum number of pixels which were
540 unsuitable, respectively dead, during the sequence. Because
541 of high pedestal rms (cars passing) a few events with very high
542 numbers of unsuitable pixels can happen. Not to suffer from this
543 effect we don't take the highest 0.1% of the numbers into account.
544
545 - general: fixed a bug which caused callisto and star to stop working
546 properly because the callisto output was currupted
547
548 - general: a script called scripts/makemovie has been added which
549 simplified the process of producing several movies from a single
550 sequence with different setup.
551
552 - callisto: Some more code cleanup. Started to remove old obsolete
553 code from cvs.
554
555 - callisto: The extraction of the pedestal with the extractor was
556 not random. It seems that extracting at one position is still biased
557 (for example in the first or last slices we could still suffer from
558 switching noise) Now it is completely random.
559
560 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
561 pedestal files) individual pixels could be skipped due to high
562 variations. This was already the case for the pedestal extraction
563 from the lo-gains since the beginning and properly handled
564 there, but was introduced in the extraction from the pedestal files
565 a while ago. To calculate the average value it was still divided
566 by the number of events procesed not by the number of summands
567 really summed. This let to a pedestal which was a tiny amount too
568 small (for a few piels in the order of 0.1%). This led to an slightly
569 positive offset of the randomly extracted pedestal for a few pixels.
570 I doubt that this has a big effect on the result, because the effect
571 on the individual numbers is quite small. Due to this it is suggested
572 that you rerun your calibration to make sure you are without any
573 avoidable bias.
574
575 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
576 the median rms of the absolute arrival time and expressed in significance
577 levels. This replaces the old meaning of an abolute upper limit. An
578 absolute upper limit doesn't make much sense, because in our data
579 all arrival times are shifted at the same time (in fact it might be
580 a shift of the artificial trigger w.r.t. to the light flash).
581
582 - callisto: Added a new tab "BadPixTm" which shows the time evolution
583 of the number of unsuitable pixels over the whole sequence. This
584 is usefull mainly to judge if an intermediate calibration had
585 problems.
586
587 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
588 of the number of dead pixels over the whole sequence. Dead pixels
589 in this context are unmapped pixels, i.e. pixels which could not
590 be interpolated, and thus are ignored in the further analysis.
591
592 - callisto: It is now possible to use the position of the maximum
593 of the spline as arrival time instead of the leading edge even
594 when using the integral for the signal. Therefor set the extraction
595 type to kIntegralRel ("IntegralRelative") and the relative height
596 ("HeightTm") to -1:
597 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
598 MJPedestalC1.ExtractSignal.HeightTm: -1
599
600
601
602
603 *** Version 1.1 (2007/04/27)
604
605 - general: The new class MGeomCamDwarf contains the camera geometry
606 for our prefered Dwarf camera and can be used to create general
607 geometries of roundish or hexagonal cameras.
608
609 - mars: The default cleaning is now abolute 8.5/4.0.
610
611 - mars: The resource file mars.rc now contains examples for MUX data
612
613 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
614 data containing only 10-bit information is still cooked down to
615 8-bit, by cutting away the lowest 8-bit.
616
617 - merpp: When reading raw data the data is now stored in a single
618 array. The lo-gain array is obsolete. The interface stays the same.
619
620 - callisto: To process the new MUX data use the resource file
621 callisto_mux.rc
622
623 - callisto: The -root and -raw options to read merpped raw data have
624 been removed
625
626 - callisto: If the -mc option is given the sequence-name can now be
627 replaced by the MC sequence number
628
629 - callisto: If the sequence file contains "MonteCarlo: Yes" the
630 -mc option can now be omitted
631
632 - callisto: Started further simplification by removing obsolete
633 dependancies on MCalibIntensity*Cams.
634
635 - callisto: removed unsused intensity calibration from MJCalibration
636 for further simplification
637
638 - callisto: for simplification removed references to
639 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
640 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
641 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
642 (this should at minimum change nothing at all, and at maximum
643 improve thing if these containers where somewhere not handled
644 properly)
645
646 - callisto: Added the option to write an event movie. Please use
647 this option with care (huge files) but exessively to understand
648 our events. For further documentation please refer to the
649 IACT wiki
650 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
651
652 - callisto: Improved binning for the pulse position check histogram
653
654 - callisto: The code calculating the pulse position checknow takes
655 the pedestal into account
656
657 - callisto: The arrival time is now stored with full precision this
658 helps to get rid of artefacts in histograms. For the signal this
659 is not necessray because it is displayed in log-scale anyhow
660
661 - callisto: Fixed a problem with internal exclusions. Pixels which
662 have once been marked as unsuitable didn't get the necessary
663 histograms filled anymore to be rechecked with each interleaved
664 calibration.
665
666 - callisto: The relative arrival time resolution (the rms of the
667 relative arrival time offset) is now checked against its
668 median and the median deviation, instead of the average
669 plus an absolute offset.
670
671 - callisto: The relative arrival time offset is now calculated
672 w.r.t. its median not w.r.t. to an artificial reference pixel.
673
674 - callisto: The relative time calibration now marks pixels with
675 outlaying offset as unsuitable
676
677 - callisto: The interleaved relative time calibration has been switched
678 on. The advantage is that pixels which are marked as outliers
679 now can recover. An improvement over time is not expected, because
680 the relative time calibration seems stable.
681
682 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
683 option can now be omitted.
684
685 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
686 or the option "-mc" is specified as default the monte carlo datacenter
687 paths (/magic/montecarlo/...) are used if not overwritten in the
688 dataset file.
689
690 - ganymed: The output files now contain run- and event-number for all
691 events, accessible as RunNumber.fVal and EvtNumber.fVal
692
693 - ganymed: Added a plot showing the source position in the camera also
694 for wobble mode
695
696 - ganymed: In addition to the existing task which can be setup to
697 be executed after Cut1 a final task called "EstimateEnergy"
698 has been added, executed before writing the final output
699 (ganymed00000000.root). The task setup in all three cases
700 can be choosen individually. (For all three(!) cases you
701 can for example choose MRanForestCalc. For examples see all
702 sponde*.rc and all ganymed*rc)
703
704 - ganymed: If a container "MEstimatedEnergy" is found in the
705 parameter list (eg. because it was setup by MEstimateEnergy)
706 it will be written to the output file.
707
708
709
710 *** Version 1.0 (2007/02/16)
711
712 - database: Website to plot values from the database has been added.
713
714 - database: The rate of spark events as found by star is now kept
715 and the rate after cleaning is now with spark events subtracted
716
717 - general: The changes to the interpretation of phrases lead to
718 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
719
720 - general: Added example files how you can create your own calendar
721 (eg. as christmas present) with Mars. Just run
722 root macros/tutorials/calendar.C
723
724 - general: Added a possibility to display grouped data in the plotdb.C
725 macro (and similar macros). This allows to plot hourly, nightly,
726 weekly, monthly and yearly averages.
727 For more details see the plotall function of the macro
728
729 - general: fixed the error display of the camera display. It showed
730 wrong results.
731
732 - general: fixed a memory leak when reading many MStatusDisplays
733
734 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
735 between a spherical and a parabolic mirror
736
737 - callisto: We have a new pulse position check which takes the properties
738 of the extractor automatically into account. So no need to set
739 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
740 left is done. If possible the lo-gain extraction start and hi-gain
741 extraction end is changed accordingly. If no proper extraction range
742 can be set (hi-gain too much to the left) an error is raised.
743
744 - callisto: New swapped pixels have been found and corrected
745
746 - callisto: Redone the signal extraction this includes:
747 + Unified the algorithms to extract the pedestal for all pedestal
748 extractions done
749 + Unification of hi- and lo-gain into one array
750 + Unification of hi- and lo-gain extraction for Spline and
751 Digital Filter (means now exactly the same algorithm is used,
752 not a copy-and-pasted one)
753 + Store pedestal subtracted data in a common place
754 + Improved extraction algorithms. If the algorithms search a
755 maximum but don't find one they don't return the maximum anymore
756 + Improved the extraction such that a information for signal
757 and time which is consistent is returned
758 + replaced the numerical spline with a (not slower) analytical
759 solution
760 + Lowered the saturation limit from 250 to 245 to make sure that
761 we are far away in all pixels from problems with the clock-noise
762 + The start of the lo-gain extraction is calculated from the hi-gain
763 arrival time. In case of saturation an estimation is used.
764 + the hi-gain window was extended to slice 16. This allows extraction
765 of very late pulses in single pixels or of huge hadron showers.
766 + Now uses the lo-gain extraction range for pedestal extraction,
767 not the hi-gain range in the lo-gain
768
769 - callisto: New hi-/lo-gain calibration constants have been produced
770 for all periods from the statistic of the whole period. They are
771 now used automatically depending on the periods. The old constants
772 where deviation in avarega about 2%-3%. The constants are very
773 stable from period to period (<<1%) except for exchanged channels.
774 In a few cases the constants used so far were off by 1%-2% (maybe
775 temperature effects?)
776
777 - callisto: To gain obsolete space we do not write the
778 MPedestalFundamental anymore. Also calibration and bad pixel
779 treatment is not done for it anymore because it has never been used.
780
781 - callisto: Fixed a bug in the seuqence handling which caused the
782 light condition to be ignored
783
784 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
785 basically the same as "Cleaned" but the distribution devided into
786 the events fullfilling a spark cut or being rejected by it.
787 This cut can be changed from star.rc (see example inside) by
788 the "SparkCut" directive
789
790 - star: Star displays now the average individual pixel-rate (IPR) versus
791 time and the average discriminator threshold (DT) of all pixels.
792
793 - optim: fixed a problem with the optim-macros which was due to a bug
794 in the new phrase parsing
795
796 - ganymed: To get a nice FalseSource plot (instead of the all-information
797 debug plot displayed as a standard plot) use the context menu
798 somewhere between the two upper plots, click on "DrawNicePlot"
799 and enjoy the result. (It is the same context menu which contains
800 the other options)
801 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
802
803 - ganymed/optim/train: The cut program, trainings- and optimization
804 macros could run with less files found than expected from the
805 sequence-files. No the execution is stopped in this case.
806
807 - ganymed: now stores the dataset in the output file with all information
808 contained (as sequence number, sequence path, data path) so that the
809 used dataset file can be recreated complete from the output
810
811 - sponde: now also allows the uasge of random forest
812
813 - sponde: added a plot showing the cut efficiency
814
815 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
816 errors (eg. effecting the collection area) because the errors of the
817 two histograms were swapped in the calculation, which makes a difference
818 in the case the histograms contains weighted events. Aditionally the
819 totalarea was incorrectly taken into account, which results in too small
820 errors, which makes a difference at low statistics were the errors
821 or the collection area dominate.
822
823
824
825 *** Version 0.10.3 (2006/10/23)
826
827 - database: Implemented ObservationMode flag in websites.
828
829 - database: For sequences there is now also the stoptime available on the
830 websites.
831
832 - database: Removed ManuallyChanged flag from sequence-info websites,
833 as it is not needed anymore with the new sequence building algorithm.
834
835 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
836 Class for calculation of confidence intervals (upper limits).
837 Use model 3 or 4 for upper limit calculation for MAGIC observations.
838 Please read the class instruction of TRolke for more information.
839
840 - general: The programs now return 0xfe if the requested resource file
841 doesn't exist.
842
843 - general: Errors comming from root itself are now not output to
844 stderr anymore but to our default (colored) log-stream.
845
846 - general: Changed the interface to TFormula such that now everything
847 is parsed by TFormula, which should allow to use phrases even
848 without paranthesis correctly parsed.
849
850 - callisto: replaced the AdHoc number of effective integration slices
851 in the digital filter by an average of the correct number, averaged
852 over all possible set of weights. This also gives correct numbers
853 for the lo-gains which were totally wrong before.
854
855 - callisto: drastically reduced memory consumption by not storing
856 all intermediate calibration results in memory anymore (we might
857 write them into a file in the future)
858
859 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
860 debug plot displayed as a standard plot) use the context menu
861 somewhere between the two upper plots, click on "DrawNicePlot"
862 and enjoy the result. (It is the same context menu which contains
863 the "DrawAll" option)
864 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
865
866
867
868 *** Version 0.10.2 (2006/10/15)
869
870 - general: changed the building of the sequence files such, that
871 the source-/project name in case of wobble-sources is not the
872 source/project of the first data run anymore but the new generalized
873 wobble source/project
874
875 - general: Added some functions to MAstro to calculate sun and
876 moon properties
877
878 - general: Added two new macros (starvisday.C and starvisyear.C)
879 which allow to plot the visibility of several stars in one day
880 or of one star along one year
881
882
883
884 *** Version 0.10.1 (2006/10/11)
885
886 - general: HTML logging output was distorted... fixed.
887
888 - general: Changed the writing of the sequencefiles such that only
889 as many pedestal files as giving at least 1000 pedestal events which
890 are nearby the first calibration run are used as pedestal runs
891
892 - sponde: In the calculation of the collection area(s) and the
893 distribution for MOnte Carlo and estimated energy the error
894 calculation was wrong because root didn't take the errors
895 properly into account... fixed.
896
897
898
899 *** Version 0.10 (2006/10/10)
900
901 - general: all executables now check consistency of the root version
902 installed with the root version used for compilation. The return
903 code in this case is 255.
904
905 - general: The algorithm to build seqeunces has been redesigned
906 completly. It is now more flexible in terms of a resource file
907 resources/sequences.rc which can be used to partly overwrite
908 the default algorithm and defined the important part of the
909 algorithm. It also takes correctly into account several ways
910 of taking wobble-data. Currently the new algorithm doesn't take
911 the number of pedestal events anymore into account (so a sequence
912 could have much less than 1000 pedestal events and data runs are
913 no-more used instead)
914
915 - general: a lot of small changes to make the code compatible with
916 root 5.12/00 and gcc 4.1
917
918 - general: Fixed some warnings thrown if more warnings are switched
919 on in the compiler
920
921 - general: Added a function to MMath which returns the Median of
922 the distribution abs(y[i]-median) but at 68:32 division instead
923 of 50:50, which is somehow the median counterpart of the rms.
924
925 - general: MAstroCatalog allows now to read calatog files (as bsc5)
926 even if they are compressed with gzip (recommended compression
927 is with "-1")
928
929 - showplot:
930 + batch mode creation of image files now works with root 5.12/00
931 + added support for writing bmp (though it never produces
932 bmp which can be read by programs like xv or gimp)
933 + added support for xml
934 + added new option to start the display with a different size, by
935 --display-width=nnn or --display-height=nnn
936 + added options to define the canvas size when the display is started
937 --canvas-width=nnn or --canvas-height=nnn
938 the option can also be used for batch-mode conversion
939 + added an option which automatically fits the display size to the
940 desktop-size: --auto-size
941
942 - merpp: didn't recognize files with the extension .raw.gz - fixed.
943
944 - merpp: allow the reports to have 1000ms due to a bug in the camera
945 program.
946
947 - callisto: New swapped pixels have been found and corrected. For
948 details see MRawRunHeader::FixAssignment()
949
950 - callisto: Callisto now raises an error if one of the input files could
951 not be opened.
952
953 - callisto: In some rare cases it could happen that in the signal
954 extraction of the digital filter the extractor returned nonsense
955 results due a wrong initializion of a variable (this happens in
956 cases in which the extracted signal is exactly zero or the
957 digital filter couldn't slide because of a too small extraction
958 window, which could happen in the lo-gain extraction)
959
960 - callisto: The lo-gains have been marked as valid in some cases
961 when they got not extracted at all (deltsumlo=deltatimelo=0) because
962 the allowed extraction range (fLoGainLast-fLoGainFirst) was
963 smaller than the number of slices (fLoGainWindowSize) needed
964 by the lo-gain extractor
965
966 - callisto: Updated absolute calibration constants (muon calibration)
967
968 - callisto: fixed a bug which caused the hi-gain saturation not
969 to be handled properly in the spline (the position of the
970 saturation was calculated incorrectly)
971
972 - callisto: fixed a bug which gave weird results if hi- _and_
973 lo-gain could not be extracted properly. In some cases hi-
974 and lo-gain have not been extracted at all and the random result
975 got calibrated. In other cases the hi-gain was saturating and the
976 lo-gain has not been extracted. For this a completly arbitraty
977 scale factor was applied to the result from extracting the
978 charge of the saturating hi-gain.
979
980 - callisto: improves handling of extracted signal if lo- and/or
981 hi-gain could not be extracted properly. If no appropriate
982 calibration of either the signal or the arrival time is possible
983 the pixel is now markes as unsuitable instead of estimated.
984
985 - callisto: Fixed a problem in the spline extraction which gave
986 weird results if the signal was extracted from the first (and
987 highest) slice (as a workaround extraction from the first
988 slice has been forbidden)
989
990 - callisto: Fixed a bug regarding the use of the QE which doesn't
991 effect the result because the default is used anyhow.
992 (The bug was there since 14/07/2005)
993
994 - callisto: Changed the default for fgLoGainStartShift to -2.4
995
996 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
997 factors to be always 10 for all pixels as soon as the first
998 calibration update has happend.
999
1000 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1001 was off by more than one slice (which gives wrong values for
1002 pixels which have saturated the hi-gain) This was a problem
1003 mainly for timing studies, not so much for the automatic standard
1004 analysis. Also the values for the Spline have been changed slightly:
1005 + Digital Filter from 1.70 to 0.95
1006 + Spline from 1.39 to 1.30
1007 The numbers were sorted out by an extensive test in the
1008 test-database.
1009
1010 - callisto: Removed the tab showing the average calibrated arrival
1011 time. It never gave useful information.
1012
1013 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1014 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1015 and both were extracted because the hi-gain was above the
1016 LoGainSwitch.
1017
1018 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1019 lo-gain pulse position (after application of LoGainOffset, which
1020 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1021 have saturated and both were extracted because the hi-gain was above
1022 the LoGainSwitch.
1023
1024 - callisto: After extensive tests a new threshold level for determination
1025 of the pulse position has been found at 50phe. This is due to the
1026 fact that for lower pulses the arrival time changes its average
1027 behaviour dramatically. It tends to the average of the extraction
1028 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1029
1030 - callisto: Added two more plots to the calibration part. The average
1031 extracted signal and the average extracted arrival time as
1032 extracted by the signal extractor (This can help debugging problems
1033 because it doesn't involve a fit)
1034
1035 - star: changed the fit for the effective on time such that initial
1036 values are calculated automatically now instead of using build
1037 in values. This makes the fit more indepedant of the underlaying
1038 rates. With a test of ~350 sequences in the test database it could
1039 be shown that the new fit gives the same result +/-1sek.
1040 The highest deviation was +5s the lowest -10s. You can now control
1041 the bahaviour with two resource values:
1042 MHEffectiveOnTime.FistBin: 3
1043 MHEffectiveOnTime.NumEvents: 12000
1044 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1045 from the resulting gamma candidates
1046
1047 - star: The Center histogram in MHHillas is now by default displayed
1048 with the colz draw-option
1049
1050 - ganymed: now produces valid error codes if failed
1051
1052 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1053 with the option "hadronness" instead of "area" or "both" if
1054 you want to use both cuts. The hadronness cut includes a fixed
1055 cut in hadronness (index 8) and a fixed cut in size (index 9).
1056
1057 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1058 the M3Long of the anti source to be not properly evaluated
1059 (actually is was evaluated as a unique random number) in case
1060 of optimization with anti-theta cut switched on. This might have
1061 lead to improper, but not necessarily wrong, optimization results.
1062
1063 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1064 how to use random forest
1065
1066 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1067 ganymed_onoff.rc. Seems to be unintentional that they were different.
1068
1069 - sponde: Since the introduction of the possibility to define a
1070 normalization energy instead of using the integral the default
1071 was not using the integral anymore but a normalization energy of
1072 1GeV. It is now the integral again.
1073
1074 - sponde: Fixed a problem in the weighting which did not allow
1075 a MC slope of -1.
1076
1077
1078
1079 *** Version 0.9.6 (2006/05/24)
1080
1081 - general: changed the binning of the azimuthal profile of the camera
1082 such that it is aligned with the 60deg boundaries.
1083
1084 - merpp: better handling of problems with the TH, TD part of the
1085 CC-REPORT for files older than 200507190 and 200412210
1086 respectively
1087
1088 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1089
1090 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1091
1092 - callisto: if an arrival time is extracted outside the fadc range is
1093 was set to the boundary before. Now a random number is assigned
1094 instead to avoid unfortunate coincidences of arrival times just
1095 by this arbitrary value.
1096
1097 - callisto: added a new option to callisto.rc which allows
1098 to set the maximum arrival time difference allowed for the
1099 badpixel algorithm to determin whether a pixels belongs to a shower:
1100 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1101
1102 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1103 to 0.9 as suggested by Stefan due to a recent study on the fraction
1104 of pixels surviving the image cleaning
1105
1106 - callisto: switched off error in case of "pulse is too much to the left"
1107
1108 - callisto: The extraction window is not adapted anymore. This means that
1109 the pulse is extracted from the full range. The draw-back is that the
1110 background (pedestal) will become slightly higher. Switching on/off
1111 the PulsePosCheck in the callisto.rc only effects filling the
1112 histograms.
1113 WARNING: If the pulse is too much to the left data is calibrated!
1114 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1115 in the database to make sure that your data is valid!
1116
1117 - star: Show also the number of stars correlated correctly by the
1118 starguider
1119
1120 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1121 than one off-source region in wobble-mode. To use it add the following to
1122 your ganymed_wobble.rc:
1123 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1124 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1125 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1126 + Cut1.ThetaCut: None
1127 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1128
1129 - ganymed: in the case the latest report is older than a default (currently
1130 one minute) and the current report will be skip the starguider
1131 correction and calibration will be reset. The maximum age can be
1132 setup from ganymed.rc by (minutes):
1133 MPointingDevCalc.MaxAge: 1.5
1134
1135 - ganymed: A first implementation showing all size-bins for the theta-sq
1136 resp. alpha-plots in a single tab automatically
1137
1138
1139
1140 *** Version 0.9.5.1 (2006/05/05)
1141
1142 - general: Added a new option "zdiff" to the Makefile which runs
1143 "cvs diff" as "make diff" would do, but with compression
1144
1145 - general: accelerated MTFillMatrix (used for eample in all training
1146 and optimization macros) by skipping some obsolete calles in the
1147 eventloop the first and second loop could be accelerated by ~20%
1148
1149 - general: Added a missing feature in the MFilterList class which
1150 prevented MFEnergySlope from working correctly in trainenergy.C
1151
1152 - general: Accelerated the random forest training and usage a bit
1153
1154 - merpp: Adapted to new raw data file format version 6
1155
1156 - merpp: fixed a problem with reading the starguider reports
1157 after 6.3.2006
1158
1159 - callisto: At some times six pixels had to be exchanged manually in the
1160 data. If the pixels to be swaped are both not found, an error was raised
1161 and calibration was stopped. Now it is assumed they are intentially not
1162 mapped and the Error has been changed to a Warning.
1163
1164 - star: Added new image cleaning based on the arrival time of the shower.
1165 The new cleaning can be accessed using the parameter "Time" instead of
1166 the the old one (like "Absolute) in the star.rc-file.
1167 Recommended parameters:
1168 + MImgCleanStd.CleanLevel1: 8.2
1169 + MImgCleanStd.CleanLevel2: 5
1170 + MImgCleanStd.CleanRings: 2
1171 + MImgCleanStd.KeepSinglePixels: No
1172
1173 - star: Simplified the calculation of the effective on time. By letting
1174 the fit start in the third bin the result should become more stable.
1175 The fit quality is now ignored for the theta-plot which is not used
1176 in the analysis later. Still better pre-cut which, for example,
1177 remove events triggered by car-light (rate changing on a short
1178 time-scale) are missing.
1179
1180 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1181 for optimization (kWeakSource) which is suggested by the Berlin
1182 people for weak sources.
1183
1184 - macros: plotdb.C:
1185 + if no dataset and no time-interval is given only sequences with
1186 an effective on-time above five minutes are plotted anymore
1187 + added a new tab "RelTime" displaying the relative on-time
1188 (effective on-time divided by the observation time)
1189
1190 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1191 the optimization became a lot faster
1192
1193 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1194 To display them just delete the pads displayed on top.
1195
1196 - ganymed: fixed a bug which could cause strange behaviour in wobble
1197 mode if no starguider information was available due to an incorrect
1198 initialization of the starguider calibration
1199
1200 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1201 be changed from within the plot. It can also be setup from the
1202 resource file using:
1203 + MHDisp.fScaleMin: 0.325
1204 + MHDisp.fScaleMax: 0.475
1205
1206 - ganymed, showplot: Fixed a problem with the fit to the off-data
1207 (HistOff) which could cause a time lag or an inifinite loop.
1208 The bug did not effect the results at all.
1209
1210 - sponde: Added a new tab showing the effective collection area after
1211 trigger (including the software trigger)
1212
1213 - sponde: MMcSpectrumWeight has a new option which allows to define
1214 the scaling factor not by the integral of the events but at
1215 a defined energy:
1216 e.g. MMcSpectrumWeight.NormEnergy: 200
1217
1218 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1219 eventloops the loop could be accelerated by ~20%
1220
1221
1222
1223 *** Version 0.9.5 (2006/03/13)
1224
1225 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1226 and added the standard Disp-parametrization
1227
1228 - macros: added a new macro datacenter/macros/plotstat.C allowing
1229 to plot statistics about the data processing
1230
1231 - macros: added a new macro to plot the muon correction coefficients
1232 versus period (macros/plot/mucal.C)
1233
1234 - showplot: path inflation for ganymed files was broken
1235
1236 - callisto: Fixed an important bug. When the number of saturating pixels
1237 were calculated the bad pixel information already available from the
1238 calibration was ignored. This yields wrong values in case pixels
1239 are broken and saturate all the time or randomly.
1240
1241 - callisto: Updated Muon calibration constants. Spline data now also uses
1242 different values for different periods
1243
1244 - star: The time-evolution shown in the effective on-time plot now displays
1245 the axis range (if there are no holes it should be similar to the
1246 effective on-time)
1247
1248 - star: Added two new image parameters:
1249 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1250 the three pixels next to the center of gravity and the size
1251 + MNewImagePar.fConcCore: The ratio of the signals of all
1252 pixels inside or touching the ellipse and the size
1253
1254 - ganymed: now stops in requested source isn't found in catalog file
1255
1256 - ganymed: Many improvements to the phi-plot in wobble mode:
1257 + with a template the ideal background is displayed
1258 + a possible camera inhomogeneity is taken into account
1259 + the anti theta cut is better supported
1260 + the phi cut is automatically calculated from the theta cut
1261 See the examples in ganymed_wobble.rc for more details.
1262
1263 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1264 times the bin-width instead of the absolute energy
1265
1266 - ganymed: New cuts for on/off and wobble mode
1267
1268 - ganymed: The smearing of the False Source plot has been increased
1269 to 0.06
1270
1271 - ganymed: The starguider calibration can now be changed from the
1272 resource file.
1273 See the examples in ganymed*.rc for more details.
1274
1275 - ganymed: added a new option for on-/off-observations
1276 MJCut.RandomSourcePosition
1277 If switched on the distribution of observation time of the source
1278 position in the camera is calculated from the on-data and randomly
1279 applied with this distrbution to the off-data.
1280
1281 - ganymed: by skipping some obsolete calles in the eventloop the
1282 first and second loop could be accelerated by ~20%
1283
1284 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1285 position in the off-data randomly according to its distribution in the
1286 on-data.
1287
1288
1289
1290 *** Version 0.9.4.3 (2006/02/13)
1291
1292 - general: Fixed a bug in most of the programs which prevented the
1293 compile date in the startup message to be displayed
1294
1295 - general: Simplified program calls. The following abbreviations
1296 are now possible:
1297 showlog callisto 55599
1298 showplot signal 55599
1299 star 55599
1300 callisto 55999
1301 ganymed 2
1302 In this cases the corrsponding root-, log-, sequence- or dataset-
1303 filename is automatically compiled using the default datacenter
1304 paths ("/magic/*")
1305
1306 - general: Fixed a long outstanding bug which made axis tick marks
1307 disappear if MDataFormula was used (eg. abs(x))
1308
1309 - general: Updated MMath with new functions to calculate the results of
1310 a exponential, logarithmic and powerlaw fits analytically.
1311
1312 - general: Updated some macros with comments:
1313 + macros/optim/optimdisp.C
1314 + macros/optim/optimenergy.C
1315 + macros/optim/optimwobble.C:
1316
1317 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1318 files) now allows adding a pre-cut like in the optimization. E.g. this
1319 is useful to perform g/h-separation cuts before training the random
1320 forest.
1321
1322 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1323 correctly assigned in the raw data assignement table. A fix to correct
1324 the assignment tabel have been implemented.
1325
1326 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1327 by 90, 180 and 270 deg.
1328
1329 - general: the macro plotdb.C now allows to highlight sequences belonging
1330 to a datset. For more details see the descritions in the macro.
1331
1332 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1333 of the display, it gave wrong results espacially for big sizes.
1334 Now the embedded canvas should always have a ratio width/height=3/2.
1335 The "Size" options have been updated with values fitting the 3/2
1336 size ratio.
1337
1338 - RanForest:
1339 + Updated the random forest classes to support also the
1340 regression method implemented by Thomas H.
1341 + added new tutorial macro how to train the random forest
1342 for energy estimation (macros/optim/rfenergyest.C)
1343 + new classes to train the random forest (still in development)
1344 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1345 + new tutorial macros for random forest training in macros/train
1346 trainenergy.C, traindisp.C, trainseparation.C
1347
1348 - mars: now allows to setup a cut in the resource file mars.rc to choose
1349 the events to be displayed, eg:
1350 Cut.Condition: {0} && {1}
1351 Cut.0: MHillas.fSize>100
1352 Cut.1: MHillas.fSize<900
1353
1354 - merpp: Made aware of the new .rep format 200510250. This includes
1355 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1356 the discriminator thresholds (MCameraTD) and the disciminator
1357 delays (MCameraTD). All of them come with the CC report and are therefor
1358 written to the CC tree.
1359
1360 - callisto: fixed a bug in the calculation of the arrival times in
1361 the Digital Filter. They were all shifted by the same amount
1362 fHiGainFirst. This caused an offset in the order of the position of
1363 the left border of the extraction window in the times calculated
1364 from high-gain and from low-gain. The bug effected only the absolute
1365 arrival times. The bug was there since 30.1.2005.
1366
1367 - callisto: Changed the ExtractionWindow for the pulse position check
1368 such that the camera inhomogeneity becomes as less as possible and
1369 comparable to the pulso position check switched off. More details
1370 on the study will be given at our result web-page.
1371
1372 - ganymed: ganymed.rc, ganymed_onoff.rc:
1373 changed to new cuts trained with 1ES1218 and Crab-data
1374 for maximum sigma*log10(excess)
1375
1376 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1377 a new option was implemented to estimate Disp (CalcDisp)
1378
1379 - ganymed: Implemented two new options which allow
1380 to overwrite the default path to search for the sequence files
1381 --ins=/magic/sequences
1382 and where to search for the image data
1383 --ind=/magic/data/star
1384
1385 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1386 dx/dy from the resource file by
1387 MSrcPosCorrect.Dx
1388 MSrcPosCorrect.Dy
1389
1390 - ganymed: fixed reading the source catalog. Only as many chars
1391 as the requested source name had were compared (If a source
1392 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1393 were requested it could happen that the coordinates of
1394 "1ES1218" were read) The source coordinates are now printed
1395 in addition to its name to the logging output.
1396
1397 - ganymed: changed the background fit in the case of a ThetaSq function
1398 from a polynomial to a exponential, this should give a big improvement
1399 for on-only analysis'
1400
1401 - ganymed/sponde: Calculation of the error of single size-/energy-
1402 bins now uses Li/Ma (5) instead of LiMa (17)
1403
1404 - sponde: Added a plot E^2*dN/dE
1405
1406 - sponde: The energy estimator plot should now show values like
1407 they are commonly used.
1408
1409 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1410 (a powerlaw with cutoff didn't work before)
1411
1412
1413
1414 *** Version 0.9.4.2 (2005/10/01)
1415
1416 - general: added new tutorial macro macros/tutorials/threshold.C:
1417 how to calculate the threshold
1418
1419 - general: added a new game. Start it from the interpreter with
1420 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1421 and MagicReversi)
1422
1423 - general: neighbor pixels in MGeoms are now sorted clockwise
1424
1425 - merpp: made aware of new format 20050829-0
1426
1427 - callisto: New scale factors from muon analysis, stored in new
1428 resource file resources/calibration.rc
1429
1430 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1431 the eventloop if something went wrong. This is necessary for the
1432 automatic processing
1433
1434 - callisto: Implemented a new treatment for the time information
1435 developed by S.Ruegamer, this should give much better response than
1436 the old very primitive algorithm. This is especially important
1437 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1438 treatment was buggy! As neighbor pixels to interpolate the
1439 arrival times always the pixels 0 to 5 were taken)
1440
1441 - callisto: In addition to the new treatment of arrival times the
1442 decision of the treatment whether a pixel contains shower
1443 information or not is used to improve the signal interpolation
1444 further. Previously interpolated pixels showed a non-zero signal
1445 do the peak searching signal extractors. Having a signal pixel
1446 beside raised the signal above the cleaning level. Thus the
1447 pixel survived cleaning to often but with a too low mean signal.
1448 By replacing empty pixels with a gaus (mean and rms from the
1449 corresponding Area entries in MPedPhotCam) this effect can
1450 be supressed.
1451
1452 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1453 got lost when the events were stored by the calibration... fixed.
1454 (This was no problem for normal image cleaning because the pixel
1455 content was artificially set to 0 not surviving standard cleaning
1456 algorithm)
1457
1458 - callisto: Fixed a bug which caused the random and peak-search pedestal
1459 extracted with an extractor to be exchanged for the first (roughly)
1460 500 events (*Extractor and *ExtractorRndm).
1461 (They were simply exchanged in callisto.cc) This bug might have been
1462 introduced in Mars 0.9.4 when the order of calculation of the two
1463 types of pedestal in callisto got exchanged. The bug only effects
1464 the first seconds of data of each sequence.
1465
1466 - star: Taking the arrival time of Muons into account the calculation
1467 of the parameters could be made independant of the noise
1468 (pedestal rms). The dependance was due to the bias of the peak search
1469 extractor. Now only a ZA dependamcy is left which is not yet fully
1470 understood.
1471
1472 - ganymed: The sequences were still not sorted correctly in any case,
1473 because they were sorted by the full qualified path name. Now they
1474 are sorted by their sequence number.
1475
1476 - ganymed: new values for the spark-event-cut
1477
1478 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1479
1480
1481
1482 *** Version 0.9.4.1 (2005/08/18)
1483
1484 - callisto: fixed some problems with the calibration in case of
1485 inteleaved events. Therefor the final and some intermediate
1486 fits are skipped which would take place on partly filled #
1487 histograms and gave wrong results or failed completely.
1488
1489 - callisto: If the intermediate finalization of the histograms
1490 calculating the mean charge of the calibration signal fails
1491 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1492
1493 - ganymed: Fixed some bugs which caused problems in On-only mode.
1494 Still the false source plot doesn't give reasonable results.
1495
1496
1497
1498 *** Version 0.9.4 (2005/08/05)
1499
1500 - general: Fixed the ZA binning. It did not correctly fit the
1501 MC binning
1502
1503 - general: Added a class to correct for the missfocussing in
1504 April (MSrcPosCorrect)
1505
1506 - general: Random Forest energy estimator should now work properly
1507
1508 - general: MHCamera now displays the profiles in deg instead of mm
1509
1510 - general: MH::SetPalette offers a lot of new palettes
1511
1512 - general: MHillas - the case of CorrXY==0 is now handled properly
1513
1514 - general: implemented the possibility to change the line and
1515 marker style of a sky-grid drawn by MAstroCatalog
1516
1517 - general: Runs in sequences and datasets are now automatically
1518 ordered (it is assumed that the order of their filenames correctly
1519 represents the order of observations) to ensure correct reading
1520 of the subsystem data
1521
1522 - general: Runs cannot be added to a sequence twice anymore. Also
1523 Sequences cannot be added twice anymore to a dataset.
1524
1525 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1526 It gave wrong results by 1./2pi
1527
1528 - showplot: got a new option to start a root interpreter, too
1529
1530 - mars: now displays a rough estimate of Disp and the third moment
1531
1532 - mars: now displays the event time MTime if available
1533
1534 - mars: show muon parameters graphically
1535
1536 - mars: now the file to open can be given as commandline
1537 argument
1538
1539 - merpp: Added support for new arehucas version >= 200507190
1540 implementing values for three temperature sensors in the
1541 counting house (MCameraAUX) and the name of the HV settings file
1542 (MCameraHV).
1543
1544 - merrp: Also fixed some problems with wrong versions numbers stated
1545 by arehucas and implemented some fixed for old versions (<200407070)
1546
1547 - callisto: MCalibrationHiLoCam can now be printed from its context
1548 menu, eg in the TBrowser
1549
1550 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1551 - 1.39 (MExtractTimeAndChargeSpline)
1552 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1553 This is important mainly for timing studies.
1554
1555 - callisto: Changed limits in MHCalibrationChargeCalc from
1556 - -100.125 to -98 (fgChargeHiGainFirst)
1557 - 1899.875 to 1902. (fgChargeHiGainLast)
1558 - -100.25 to -99 (fgChargeLoGainFirst)
1559 - 899.75 to 901. (fgChargeLoGainLast)
1560 Introduced new limits:
1561 - fgNumLoGainBlackoutLimit: 0.05
1562 - fgLoGainBlackoutLimit: 3.5
1563 - fgLoGainPickupLimit: 3.5
1564
1565 - callisto: The handling of automatic weights for the digital filter
1566 has been improved. There are now new calibration weights special
1567 for Monte Carlo calibrations.
1568
1569 - callisto: Updated Muon scale with latest results (1% difference
1570 for most data, 5% for Mar/Apr'05)
1571
1572 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1573 was saturated and the blackout-events in the low-gain exceed the
1574 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1575 This excludes those pixels which have a saturating high-gain
1576 channel, but the low-gain switch does not switch often enough
1577 to make the distribution reliable.
1578
1579 - callisto: fix a bug counting the number of saturated events. Up to now,
1580 the number of saturated slices was counted (which is one for a not too
1581 high number), but for some (pathological) pixels, many more slices
1582 saturated and produced wrong limits.
1583
1584 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1585 + MCalibrationRelTimeCam.CheckFitResults: Yes
1586 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1587 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1588 + MCalibrationRelTimeCam.CheckOscillations: Yes
1589
1590 - callisto: introduce max. number of events for intercalibration,
1591 the rest gets skipped. Default: 4096
1592 The calibration causes too many un-reliable pixels if more
1593 than about 5000 events are treated (@500 Hz) because of the
1594 mode hopping of the VCSels. However, in the past, some
1595 calibration runs have been taken (erroneously) with more
1596 than 5000 events, especially the intensity scans where
1597 a good precision is needed.
1598
1599 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1600 photo-electrons for the spline extractor by 1-2% (correctly).
1601
1602 - callisto: The intercalibration is now done using a full f-factor
1603 method instead of a simple update. This makes things slower but
1604 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1605 changes.
1606
1607 - callisto: MPedestalY3 now uses the same extraction range as the data
1608 as calculated by MPedestalY2
1609
1610 - callisto: A check of the fraction of allowed unsuitable (10%) and
1611 unreliable (30%) pixels has been addded when the conversion is
1612 calculated from interleaved events
1613
1614 - star: fixed a bug which caused MEffectiveOnTime containers not to
1615 be written. In the worst case they were skipped almost all, in the
1616 best case they were all ok. It depends on how often the new value
1617 was assigned just with an event which was skipped later by another
1618 task
1619
1620 - star: new histograms MHPointing and MHRate
1621
1622 - star: New tab (Currents) displaying the time evolution of the mean
1623 DC currents
1624
1625 - star: New tab (MeanRms) displaying the time volution of the mean
1626 Pedestal Rms
1627
1628 - star: Output now contains MReportStarguider
1629
1630 - star: Improved muon analysis. Due to the absense of a constant
1631 for the gaus fit for arc width and the fact that the arcwidth
1632 plot was a histogram instead of a profile the resulting psf
1633 became pedestal rms dependant
1634
1635 - ganymed: added new plot (MHPhi) for wobble mode as described in
1636 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1637
1638 - ganymed: corrects now (correctly?) for the misspointing in
1639 May/April 05
1640
1641 - ganymed: Two new default templates for ganymed.rc are avilable:
1642 ganymed_onoff.rc and ganymed_wobble.rc
1643
1644 - ganymed: The first version of MFMagicCuts has been released
1645
1646 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1647
1648 - ganymed, sponde: There are two new options to determin the number
1649 of bins for the signal region (NumBinsSignal) and the number of
1650 total bins (NumBinsTotal) in the MHThetaSq histogram
1651
1652 - ganymed: optimized palettes for MHDisp
1653
1654 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1655 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1656 sqrt(2) to large
1657
1658 - ganymed: The false source plot (MHDisp) is now based on Disp
1659 and a background model determined in the first loop is
1660 subtracted
1661
1662 - ganymed: MFMagicCuts are now available in the cvs. The correct
1663 solution for the disp ambiguity problem is now calculated using
1664 the third moment. The third moment cut therefor is skipped.
1665
1666 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1667 already determined by the third moment along the major axis and
1668 so its actual sign is aligned along the major axis of the shower.
1669
1670 - ganymed: If starguider data is available it is taken into account
1671 when calculating the source position. This is especially important
1672 for wobble data at high zenith angles and culmination data.
1673
1674 - ganymed: If available the starguider data is taken into account as
1675 good as it is possible without a starguider calibration. To switch
1676 it off add
1677 MPointingDevCalc.MaxAbsDev: -1
1678 to your ganymed.rc
1679
1680 - sponde: the zenith angle distribution is now weighted instead of
1681 choosen by default. This gurantees higher statistics in the highest
1682 and lowest energy bins. To switch this behaviour off use...
1683
1684 - sponde: now automatically displays the energy threshold
1685
1686
1687
1688 *** Version 0.9.3 (2005/06/03)
1689
1690 - general: MMcEvt now derived from MMcEvtBasic which should
1691 have no influence on compatibility with older camera files
1692
1693 - general: Implemented a new option to MReadReports which allows
1694 to force reading of the first event of some trees (eg. Drive-tree)
1695 before any other tree.
1696
1697 - general: Made a fix to MPointingPosCalc which assumes that the
1698 run-type is real-data if Process is called before ReInit, such
1699 that also the very first Drive-events in a run are treated
1700 correctly.
1701
1702 - shoplot now displays the filename in the title bar of the window
1703
1704 - merpp: new options: --auto-time-start --auto-time-stop which
1705 allow to cut updating with slow-control at the start- or
1706 (previousle --auto-time only allowed: and) stop-time of
1707 the run stored in the runheader.
1708
1709 - callisto: changed default of fgFallTimeHiGain in
1710 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1711 already set as default in callisto_Dec04Jan05.rc
1712
1713 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1714 now changes the filename for new weights automatically for
1715 cosmics, MC and for different calibration colors.
1716
1717 - callisto: a problem with the order of some code cause the
1718 name of the weights file in MPedestalY2 to be ignored.
1719 Wrongly the calibration_UV weights were used instead
1720 of the cosmics weights set in callisto.rc.
1721
1722 - callisto: should allow ct1 pulser data when the color is
1723 explicitly set also for pretty new runs
1724
1725 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1726 to introduce an additional scale factor (should be around 1)
1727 to adapt for slight deviations in different extractors from
1728 the MC calibration. For MC calibrations the scale factor
1729 is fixed to 1
1730
1731 - callisto: MFCosmics should handle very high signals a bit
1732 more accurate now
1733
1734 - callisto: when calculating the mean pedestal rms for different
1735 pixel sizes or sectors also kUnsuitableEvt is now taken into
1736 account - not only kUnsuitableRun
1737
1738 - callisto: '-raw' option is now the default
1739
1740 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1741 This has the advantage that mean values in the calibration (eg
1742 arrival times) are calculated more accuratly.
1743
1744 - callisto: In the resource file callisto_Dec04Jan05.rc
1745 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1746
1747 - callisto: new Hi-/Lo-Gain intercalibration constants
1748 hilocalib_sp1.root and hilocalib_sp1_mc.root
1749
1750 - callisto: changed default for MJPedestalY2.MaxEvents
1751 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1752
1753 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1754 has changed from 9.0 to 6.0. This is necessary to exclude two very
1755 ringing pixels in September which - when kept - destroy the image
1756 cleaning around them (Markus G.)
1757
1758 - callisto: (!) The Muon analysis of all data taken so far has
1759 suggested that different extractors give slightly different
1760 absolute results after calibration, due to there different
1761 handling of the calibration- and cosmics pulse shape. Although
1762 the over all calibration seems to be a bit to pesimistic (or
1763 the MC seems to be a little bit - 3-5% - too much attenuated).
1764 There for correction factors have been introduced which correct
1765 the calibration constants by
1766 0.956937799 for Digital Filter (callisto.rc)
1767 and
1768 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1769 calibration. The main advantage is, that both data types can
1770 be easily analysed together and compared to the same MC sample.
1771 The factors are choosen such, that the reference is now a
1772 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1773
1774 - star: fixed a bug which caused the first bin of the histograms
1775 vs time to disapear in PostProcess. This gave wrong results
1776 on the screen. The output and all following programs not
1777 directly accessing the histograms haven't been affected
1778
1779 - star, ganymed: Made sure that always the first Drive-tree event
1780 is read and Processed before the first data event was read.
1781
1782 - ganymed: implemented the possibility to replace the standard
1783 false source plot with a different one. For example: If
1784 you want to use a Disp based FS plot use the resource:
1785 NameHistFS: MHDisp
1786 For details about the requirements of these plots look
1787 at the corresponding classes
1788
1789 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1790 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1791 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1792 case MAlphaFitter is setup correctly. For On-Only optimization
1793 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1794 RunOn() instead of Run(). For energy estimation MJOptimize
1795 has been replaced by MJOptimizeEnergy
1796
1797 - sponde: The input MC spectrum can now be weighted to fake a
1798 different spectrum. This is done via MMcSpectrumWeight. For
1799 more details see the class description and sponde.rc
1800
1801 - sponde: The paremeter comparsion plots are not scaled by
1802 their entries anymore. Instead the MC plot is scaled by using
1803 the result spectrum of the analysis. If the input MC spectrum
1804 and the result spectrum has different slopes the absolut
1805 normalization is normally wrong.
1806
1807
1808
1809 *** Version 0.9.2 (2005/05/20)
1810
1811 - general: Changed the default paths for calibrated data and image
1812 files. (The implemented access to these files doesn't yet exist)
1813
1814 - general: support for MRunIter has been removed from the job classes
1815 (use the setter functions of MSeqeunce instead)
1816
1817 - general: ProcessFile has been renamed to Process in all job classes,
1818 because ProcessFile is missleading
1819
1820 - general: The storage of the palette in MHCamera is now possible
1821
1822 - general: new bits describing unsuitable and unreliable pixels have
1823 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1824 kDeadPedestalRms, kFluctuatingArrivalTimes
1825
1826 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1827 versions newer than V200404070
1828
1829 - general: support for cc file versions newer than V200504130. Added
1830 support for active loads (MCameraActiveLoad) and central pixel
1831 (MCameraCentralPixel)
1832
1833 - general: added new histograms for image parameters versus size
1834 (MHVsSize)
1835
1836 - general: The eventloop now automatically calls PrintStatistics
1837
1838 - Status Display: Improved support for printing:
1839 + A default can now be set in .rootrc (for more details see
1840 MStatusDisplay::PrintPS)
1841 + A print dialog is opened so that printer and command line
1842 can be canged
1843
1844 - showlog: improved such that it handles different verbosity levels
1845 more accurate now. This mean you can suppress output when
1846 using showlog.
1847
1848 - showplot: improved
1849 + The new graphics formats have been implemented
1850 (pdf, svg, png, jpg and xpm)
1851 + Implemented an interface for printing. Because you can change
1852 the printing command from the command line you can use all
1853 the nice postscript tool. To print a booklet for example call:
1854 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1855 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1856 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1857
1858 - callisto: fixed a bug in the recognition of the calibration bit
1859 pattern. Concerns only intensity calibration. (The strength of the
1860 intensity has been updated in some cases)
1861
1862 - callisto: add a filter against PIN Diode events when running over
1863 calibration runs since some of the recent calibration runs have
1864 been taken with Pin Diode.
1865
1866 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1867 39943, 44833 in the calibration (MCalibColorSet)
1868
1869 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1870 been set to 1e-18 in callisto_Dec04_Jan05.rc
1871
1872 - callisto: in callisto_Dec04Jan05.rc: set value for
1873 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1874 statistics for the calculation of the mean pulse time
1875 of the cosmisc
1876
1877 - callisto: the charge limit in the calibration has been raised
1878 from 2.5 to 4.5
1879
1880 - callisto: new setup read from callisto.rc
1881 + MCalibCalcFromPast.fNumEventsDump
1882 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1883 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1884
1885 - callisto: MExtractTimeAndChargeSpline extractor:
1886 + The integration ranges were shifted by 0.2 FADC slices to the right.
1887 + unreliable handling of floating point values caused different
1888 results on different platform or with different compiler options:
1889 The new algorithm is numerically exact and more accurate because
1890 it doesn't calculate the integration position by multiple times
1891 adding the step-size (which results in numerical uncertanties
1892 exspecially if multiplied with large numbers)
1893 + A lot of fixes have been introduced which effects integrating the
1894 spline at the edges of the valid range. In this case any memory
1895 was randomly accessed. This behaviour can be tested replacing
1896 all MArrayF by TArrayF which perform a range check (but of course
1897 they are a lot slower)
1898 ! No result obtained with the Spline before can be trusted! Due to
1899 random memory access it might by completely random!
1900
1901 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1902 + extraction range in the high gain to 4.
1903 + weights file to cosmics_weights46.dat
1904
1905 - callisto:
1906 + introduce the check for fluctuating arrival times.
1907 + set charge limit to from 2.5 to 4.5
1908 + introduce asymmetric exclusion due to "deviating number of phes":
1909 Default: -9.0 +4.5
1910 + make deviating number of phes unsuitable (see David's findings).
1911
1912 - callisto: fixed the display of unsuitable pixels. The old change
1913 to a real profile in MHCamera broke it.
1914
1915 - callisto: The cosmics filter is used in MJCalibration now
1916 independant of the pulser color (formaly it was used only for
1917 CT1-pulser data). The threshold of number of max empty pixels
1918 has been raised from 2% to 5% in MJCalibration. The maximum
1919 fraction of rejected event is 50% otherwise the calibration has
1920 failed. The filter now ignores unsuitable pixels.
1921 Setup the filter from callisto.rc using "ContCosmics"
1922 (see MFCosmics::ReadEnv)
1923
1924 - callisto: changed default for fgOffsetFromLogain back
1925 from -2.8 to -1.8 in digital filter.
1926
1927 - callisto: for the common extractors
1928 + MExtractFixedWindow
1929 * MExtractTimeAndChargeSlidingWindow
1930 * MExtractTimeAndChargeSpline
1931 * MExtractTimeAndChargeDigitalFilter
1932 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1933 and fResolutionPerPheLoGain
1934
1935 - callisto: Updated the hi-/lo-gain intercalibration constants
1936 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1937 hilocalib_df6.root
1938
1939 - callisto: The default lo-gain extraction window for the
1940 MExtractTimeAndChargeSlidingWindow extractor has been increased
1941 from 6 to 8 to take the stretch of the pusle into account
1942
1943 - callisto (!!!): fixed an important bug in the setting of the
1944 incoming pedestal pointer to the signal extractor extracting
1945 pedestals. This bug caused the pedestals not to be subtracted
1946 correctly in the calibration afterwards. The effect was about 10%
1947 too high conversion factors for the digital filter and the spline
1948 and more than 40% for the sliding window.
1949 The bug existed since end of February! (Markus G.)
1950
1951 - star: added muon support to star. A new tab "MHMuonPar" is
1952 displayed. The lower right plot is an estimate of the point spread
1953 function. A reference value is displayed. To get the real PSF
1954 you must compare with MC. The setup for the muon analysis
1955 is done in star.rc. More informations can be found in
1956 MHSingleMuon and MHCalibParCalc
1957
1958 - star: The weather data is now displayed in star
1959
1960 - star: MEventRateCalc handles the calculation of the event rate more
1961 accurate now in case of the start of a new run inside a sequence
1962
1963 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1964 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1965 changed only minimally
1966
1967 - ganymed: (MJCut and MJOptimize) now displayes the number of
1968 excess events versus size. The energy estimation is done in
1969 MJSpectrum (sponde)
1970
1971 - ganymed: got support for using other variables than Alpha, eg. Theta.
1972 Therefor you need a class deriving from MHAlpha which supports
1973 this variable (one is already existing: MHTheta, which is now the
1974 default in ganymed). It is setup through ganymed.rc
1975
1976 - added a full featured spectrum program (sponde) which reads
1977 ganymed output and monte carlos and compiles a spectrum
1978
1979
1980
1981 *** Version 0.9.1 (2005/04/14)
1982
1983 - Fix bug on the arrival time reconstruction when using Digital
1984 Filter (in some marginal cases (10%) times were reconstructed shifted
1985 by 0.2 slices)
1986
1987 - all executables now return 2 where in previous versions -1 has
1988 been returned (gave problems with shell-scripts)
1989
1990 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1991 also done with a intercalibration input file
1992
1993 - a bug in the time fine adjustment of the digital filter has been fixed
1994
1995 - a lot of small fixes to calling TPad::Divide with a margin==0
1996
1997 - MStatusDisplay now shows the memory usage
1998
1999 - added a memory leak statistic after the eventloop
2000
2001 - MHadronness replaced by MParameterD
2002
2003 - MEnergyEst replaced by MParameterD
2004
2005 - wobble mode can now be switched on from the data-set
2006
2007 - switched on bad pixel detection for a pedestal level
2008 which is more than 5 times the variance
2009
2010 - Fixed default paths to be correct for the new data center
2011
2012 - Fixed handling of drive data. The pointing position in now
2013 copied to MPointingPos inside star for real and MC events
2014
2015 - made sure, that the sequences in a dataset are sorted by
2016 their number to ensure the correct synchronization
2017
2018 - added all resource files necessary to handle spline extraction
2019 of signal for the late 2004 and the early 2005 data
2020
2021 - update the reference lines for the december data
2022
2023 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2024 This is important for the Dec. and Jan. data where the calibration
2025 pulse position changes much.
2026
2027 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2028 filter. This corrects only an defective extraction of the MC at
2029 low-gain signals lower than 90 phes.
2030
2031 - fixed some slowdown in calibrating data with interleaved events from
2032 Jan and Dec. As a workaround made the pretty palette the default.
2033 The inverse Deep Blue Sea has a bug which slows down long calibration
2034 runs a lot.
2035
2036 - implemented new values from new starguider report as defined
2037 in TDAS00-07 V7.1 (eg SkyBrighness)
2038
2039 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2040 in starguider report (If you merpp the same reports with this version
2041 you'll get the correct units (arcmin) but a different result
2042 than with old versions (wrong units))
2043
2044 - Now the status display can also write PNG, JPEG and XPM (other file
2045 formats are still unsupported by root)
2046
2047 - added a lot of scripts and macros in directory datacenter used
2048 for automatic processing
2049
2050
2051
2052 *** Version 0.9 (2005/03/23)
2053
2054 - Calibration is now done autmatically into photo-electrons like
2055 decided by the Collaboration Board
2056
2057 - Reference lines in the display can be read from resource file
2058
2059 - Interlaced calibration events can be handled by callisto
2060
2061 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2062 and applied in callisto.
2063
2064 - class MJCalibTest can be called by callisto
2065
2066 - callisto can now run with three data types: rawdata, rootdata, MC
2067
2068 - added two classes mreport/MReportStarguider.cc and
2069 mreport/MReportStarguider.h for implementing starguider-data
2070
2071 - the output of merpp-update now contains starguider information:
2072 MReportStarguider and MTimeStarguider
2073
2074 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2075 values were lower than they should. This was more visible for high
2076 energy (Size) events.
2077
2078 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2079
2080 - added a new loop to callisto to support the correct extraction of
2081 the pedestal and pedestal rms through the signal extractor
2082
2083 - added class to perform fourier tranformation of a hexagonal structure
2084 (MHexagonalFT)
2085
2086 - added class to perform fourier tranformation of a hexagonal structure
2087 in a tasklist (MHexagonalFTCalc) example: hft.C
2088
2089 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2090 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2091 small pixels, example: extendcam.C
2092
2093 - added possibility to write data to memory (TTree) using MWriteRootFile
2094
2095 - added possibility to read a TTree stored only in memory by MReadTree
2096
2097 - new classes to deal with the interleaved calibration events:
2098 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2099
2100 - implemented filters to callisto to skip calibration events
2101
2102 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2103 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2104 the slices by statistics
2105 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2106 signal extractor without randomization
2107 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2108 with the signal extractor with randomization (extraction window is
2109 randomly fixed)
2110 The three kind of pedestal is not yet implemented (for speed reasons) as
2111 long as nobody really needs it:
2112 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2113 extracted with the signal extractor with randomization
2114
2115 - callisto now finds the pulse position in the data automatically
2116
2117 - implemented data reduction in calibrated data by reducing the precision
2118 of the stored floating point values (pedestal, rms and signal) to
2119 roughly 0.5%
2120
2121 - fixed showplot to make file format conversion (eg. converting a
2122 status display stored in a root file into a postscript file) in
2123 batch mode possible:
2124 showplot -b --save-as-ps[=outfile.ps] infile.root
2125
2126 - Allow class names as part of filter rules, eg
2127 (MFSupercuts) && (MHillas.fSize>100)
2128
2129 - fixed a lot of stuff to allow all programs to process MonteCarlo
2130 camera files.
2131
2132 - enhanced possibility to debug reading of resource file
2133
2134 - MDataChain should handle priorities of operator more
2135 accurate now
2136
2137 - completely revised the container in which the signal is stored
2138 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2139 * the new implementation is faster and
2140 * needs less storage space
2141
2142 - FIRST version which can process Monte Carlos through the
2143 whole chain of programs (callisto, star, etc)
2144
2145 - implemented new image parameters for the border length of
2146 the shower image (MNewImagePar2)
2147
2148 - implemented wobble-mode in ganymed
2149
2150 - new class (MJOptimize) taking care of all optimization processes
2151
2152
2153
2154 *** Version 0.8.6 (2004/10/05)
2155
2156 - New combined signal and time extractor
2157 MExtractTimeAndChargeDigitalFilter
2158
2159 - The Report for the trigger section in the CC run summary has been
2160 updated, and now the IPRs (Individual Pixel Rates) are available.
2161
2162 - new macros for database interaction: filldotrun.C, filldotrbk.C
2163
2164 - added new program which can convert colored output which was redirected
2165 into a file back into colored text (for example to display it with
2166 more): showlog
2167
2168 - added new program to display an MStatusArray of plots (stored with
2169 MStatusDisplay) from a file: showplot
2170
2171 - Added support for Sequences (MSequence). Sequences are blocks of run
2172 files containing the same calibration and belonging to the same
2173 source
2174
2175 - Added a new task (MTaskEnv) which can be used in setup files to switch
2176 between different tasks (for example to choose a signal extractor)
2177
2178 - Implemented automatic file splitting in MWriteRootFile
2179
2180 - After image cleaning an island index is assigned to all used pixels.
2181 The index corresponds to the order of the islands in size.
2182
2183 - added a cleaning which takes signal height _and_ arrival time into
2184 account: probability cleaning (for more details see MImgCleanStd)
2185
2186 - added a cleaning which takes takes the absolute number of photons
2187 times the area ratio as cleaning level
2188 (for more details see MImgCleanStd)
2189
2190 - Changed calculation of image parameters such, that it can be done
2191 for all used pixels or the pixels with a defined island index only
2192
2193 - implemented new image parameters displaying the number of islands,
2194 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2195
2196 - event display in executable changed to support also calibrated files
2197 (done with MJCalibrateSignal)
2198
2199 - added program doing the calibration and the signal extraction
2200 and signal calibration: callisto Most part of the setup is done
2201 by a resource file: callisto.rc
2202
2203 - implemented support for pixels with negative IDs (Raw file format
2204 version 4)
2205
2206 - implemented an new option in merpp (--auto-time) to get the time
2207 range for cc and/or caco data from the run header of the raw data
2208
2209 - New star-program (star and MJStar). Taking calibrated data from
2210 callisto/MJCalibrateSignal as input. The setup is done through
2211 a resource file: star.rc
2212
2213 - Added possibility to setup the eventloop in the mars-executable
2214 Camera Display by a resource file: mars.rc
2215
2216 - The the mars-executable Camera Display can now also read
2217 calibrated data files written by callisto/MJCalibrateSignal
2218
2219 - Added a new class which can calculate the source position in
2220 the camera from a pointing model known to be correct and
2221 the pointing model used for observations (MSrcPosFromModel)
2222
2223 - added a new version of the class calculating the effective on-time
2224 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2225 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2226 MHTimeDiffTheta.
2227
2228 - added the possibility to count how often a signal is above (or
2229 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2230 can replace MHTriggerLvl0)
2231
2232 - added ore convinient ways to set the axis-titles of your histograms
2233 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2234 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2235
2236
2237
2238 *** Version 0.8.5 (2004/08/06)
2239
2240 - new Signal Extractors: MExtractFixedWindowSpline
2241 and MExtractAmplitudeSpline
2242
2243 - implementes interleave in merpp to be able to merpp parts of a file
2244
2245 - implemented force-functionality to merpp
2246
2247 - star display to display star catalogs (MAstroCatalog)
2248
2249 - star display to 'mirror' stars to the camera (MAstroCamera)
2250
2251 - implemented a new cleaning option which allows cleaning scaled with
2252 the real ratio of the rms depending on the pixel size, not only the
2253 square root of the pixelsize (MImgCleanStd, MCameraData)
2254
2255 - removed obsolete MBlind* classes
2256
2257 - Signal extractor taking the AB flag into account implemented (this makes
2258 an odd number of slices for signal extraction possible
2259 (MExtractSignalABcorr)
2260
2261 - implemented a class extracting the pedestal from the raw-data (events)
2262 itself using empty lo-gain (MpedCalcFromLoGain)
2263
2264 - Added mean values to MPedPhotCam
2265
2266 - Added Makefile for Darwin (this OS is NOT officially supported!)
2267
2268
2269
2270 *** Version 0.8.4 (2004/04/19)
2271
2272 - new fast arrival time extractor using cubic splines:
2273 MExtractTimeFastSpline
2274
2275 - implementes multi-argument support in MDataChain
2276 ("pow(a, b)")
2277
2278 - implemented double reference support in MDataChain
2279 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2280
2281 - added support in MF for expressiond like
2282 "MHillas.fWidth<2*<MHillas.fLength"
2283
2284 - MDataChain is now able to support variables like [0], [1], ...
2285 which can be used in fit functions as parameters. The interface
2286 is implemented through the new virtual function
2287 MParContainer::SetVariables
2288
2289 - added new class MArrivalTimeCam/MArrivalTimePix:
2290 Storage containers to hold the ArrivalTime of the camera/pixel
2291
2292 - added new classes for the calibration of relative arrival times:
2293 MCalibrationRelTimePix and MCalibrationRelTimeCam
2294
2295 - added new classes to extract the signal of the blind pixel and the
2296 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2297
2298 - added new classes for the bad-pixels treatment (MBadPixels*)
2299 which are more powerfull than the old ones (MBlindPixel*)
2300 and will replace them.
2301
2302 - added filter against cosmics: MFCosmics
2303
2304 - added new class MArrivalTimeCalc2:
2305 Calculates the arrival time as the signal weighted mean of the time
2306 slices in the maximum window
2307
2308 - added a new macro call pointspreadfucntion.C that fits with a 2D
2309 gaussian the DC spot for an star. It gives you the RMS of
2310 the PSF and the center of the star, very useful for misspointing
2311 studies.
2312
2313 - added support for multi-telescope camera files. Added classes
2314 MStereoCalc and MStereoPar, classes to calculate and store shower
2315 parameters calculated from the data of two telescopes, for the MC
2316 studies regarding the MAGIC clone.
2317
2318 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2319 MC data calibrated in photons instead of ADC counts.
2320
2321 - added three macros to show the calibration and analysis chain of
2322 MC data. The macro starmc.C does both calibration and analysis, producing
2323 an output containing Hillas parameters for each event. The macro
2324 mccalibrate.C does just the calibration and writes out a file containing
2325 pixel information in photons instead of FADC data. The macro starmc2.C
2326 reads in such a file and produces an output with Hillas parameters.
2327
2328 - added MPedPhotCalc to compute pedestals in units of photons, see
2329 macro pedphotcalc.C
2330
2331 - added all class to perform the calibration, see macro calibration.C
2332
2333 - added class MFFT to perform Fast Fourier Transforms
2334
2335 - added class MSimulatedAnnealing to perform simulated annealing
2336 minimizations
2337
2338 - added new macro bootcampstandardanalysis.C which holds the skeleton
2339 of the analysis chain discussed in the december bootcamp.
2340
2341 - added support for DAQ raw data file format V2
2342
2343 - implemented an arbitrary time stamp for the events from raw-data
2344 files with file version<3. It is calculated from the run number,
2345 the date of start and the FADC clock tick from the first module
2346
2347 - implemented the correct decoding of the event time-stamp
2348 coming from the DAQ for raw-data files with file-version>2
2349
2350 - added a new classes storing the pedestals in units of photons:
2351 MPedPhotPix, MPedPhotCam
2352
2353 - added support for DC current files from the camera control
2354
2355 - added support for start- and stop-time when merpping report files
2356
2357 - added MReportCC storing the weather data from the CC-REPORT
2358
2359 - added class to fill trainings and test matrices (MTFillMatrix)
2360
2361 - added a filter performing a software trigger (MFSoftwareTrigger)
2362
2363 - Added classes to perform parts of the standard analysis (Jobs):
2364 + MJPedestals
2365 + MJCalibration
2366 + MJExtractSignal
2367 Note: All of them are preliminary!
2368
2369 - Added Iterator to iterate over files giving only the run-number
2370
2371 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2372 the evolution of a sector vs time
2373
2374
2375
2376 *** Version 0.8.3 (2003/12/05)
2377
2378 - adapted Random Forest classes to allow the use with MC
2379 multi-telescope files which can be produced with the coming
2380 camera version 0.7.
2381
2382 - added classes to read and interprete central control report files
2383 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2384
2385 - enhanced merpp (the executable) to support .raw and .rep files.
2386
2387 - added classes for light calibration (MCalibration* and
2388 MHCalibration*) by Markus Gaug. Further work has to be and will
2389 be done soon.
2390
2391 - Added a preliminary 'synchronizer' (MReadReports) which will
2392 replace MReadMarsFile as soon as it is finished.
2393
2394 - Added a tutorial macro demonstrating how report files are merpped
2395 and how they can be read from the root file in the correct order
2396 of time (readrep.C)
2397
2398 - Added a generalized histogram (similar to MH3) called MVsTime
2399 which allows to plot variables (or rules - MDataChain - of
2400 variables) vs time. For an example have a look at tempvstime.C.
2401
2402 - Changed the name of the event trees:
2403 + Events --> Events
2404 + PedEvents --> Pedestals
2405 + CalEvents --> Calibration
2406
2407 - changed name of MTime in the event trees from MRawEvtTime to MTime
2408
2409 - added displaying the sector indices to the mars event display
2410
2411 - Magic Online Analysis (MOnA) implemented in a first version
2412 (see mona.cc, MOnlineDump and MOnlineDisplay)
2413
2414 - added classes to calculate event rate
2415 (preliminary: MEventRateCalc, MEventRate)
2416
2417 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2418
2419 - added classes dealing with the telescope pointing position (MPointing*)
2420
2421 - implemented the 'final' Mars time stamp based on some experiences with
2422 the new 'Synchonizer'
2423
2424
2425
2426 *** Version 0.8.2 (2003/11/10)
2427
2428 - accelerated standard analysis by a factor of 6-8 ...
2429 + doing precalculations in MGeomCam for the pixel area ratio
2430 + creating a look up table for the single pixels in MCerPhotEvt
2431
2432 - added task to calculates weights in case you want to 'change'
2433 the energy spectrum of a monte carlo file
2434 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2435
2436 - added a new executable star which implements the
2437 star.C macro as precompiled executable. Currently a flexible
2438 setup is not possible, but a 'input card' setup will follow.
2439
2440 - Starting to implement Multi-Telescope-Support based on the
2441 upcomming camera version 0.7. The base for a general support
2442 is implemented and the star-functionality is proven to work.
2443
2444 - Replaced Event-Display in and Camera-Display in the Mars GUI
2445 executable by a more convinient display base on MStatusDisplay.
2446
2447 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2448
2449
2450
2451 *** Version 0.8.1 (2003/10/20)
2452
2453 - added signal subtraction for pure on data by means of fitting
2454 the background in the off region or by performing a combined
2455 signal/background fit. Provides necessary histograms for
2456 obtaining energy spectra and a light curve.
2457
2458 - added classes to perform and study the selection of the
2459 2nd Level Trigger on MC data (example in triglvl2.C macro)
2460
2461 - added pedestal calculation
2462
2463 - implemented "democratic cleaning" (tail cut value proportional
2464 to pixel area) according to Wolfgang's suggestion.
2465
2466 - added Sigmabar treatment (calculation and basic histogramming)
2467
2468 - added basic routines to apply padding
2469
2470 - added first implementation of MARS-based source visibility plotter
2471 (needs to be linked against slalib, preliminary version)
2472
2473 - enhanced functionality of data chains: random numbers, conversion
2474 functions and access to MHMatrix objects
2475
2476 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2477 numbers under certain circumstances (runs with 0 events included)
2478
2479 - fixed a bug in the general filter MF (didn't work on some systems
2480 at all)
2481
2482 - fixed a bug in chaining files, which caused the analysis to crash or
2483 ignore files
2484
2485 - implemented more geometry classes describing the parameters used
2486 to simulate the PMT camera
2487
2488 - added new Monte Carlo classes containing the setup of the different
2489 programs in the MC chain.
2490
2491 - added a (preliminary) general task to evaluate chi-square of a given
2492 parameter in an eventloop.
2493
2494 - first implementation of a container describing the observatory
2495 location (Long, Lat, etc)
2496
2497 - added Random Forest - method for g/h-separation
2498
2499 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2500 (this means, that it is compiling, but not yet fully tested)
2501
2502 - added a new status display which can show the present status
2503 of histograms while an eventloop is running (MStatusDisplay,
2504 an example can be found at status.C)
2505
2506 - reorganized directories:
2507 classes describing the image --> mimage
2508 classes containing Monte Carlo Histograms --> mhistmc
2509 classes for Random Forest method --> mranforest
2510
2511 - added (event-)weights to fill histograms
2512
2513 - colors in logging output to screen
2514
2515 - changes to the Image Parameter declaration:
2516 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2517 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2518 + MHillasExt now derives from MParContainer instead of MHillas
2519 --> Files written with the old definition are more or less unreadable
2520
2521 - reading of reflector files
2522
2523 - display data from reflector files in the camera
2524
2525 - implemented currents (and display them in the camera)
2526
2527 - logarithmic scale in camera
2528
2529 - added class to iterate through directory contents (MDirIter)
2530
2531
2532
2533 *** Version 0.8 (2002/11/18)
2534
2535 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2536
2537 - corrected 48(!) wrong entries in the Next Neighbor table of the
2538 Magic Camera (all in the inner part of the outer ring, mostly
2539 missing a single NN)
2540
2541 - Fixed a bug in the table describing the Next Neighbours of the
2542 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2543 have any neighbour)
2544
2545 - changed trigrate.C: now it calculates the pure NSB triggers from
2546 a camera file (generated with no showers), so there is no need
2547 to introduce them by hand in the BgR array (for more details
2548 please ask Abelardo)
2549
2550 - added MHHadronness (and MHadronness) as a general facility to evaluate
2551 the quality of a gamma-hadron seperation method
2552
2553 - changed MWriteAsciiFile to accept rules (MDataChain)
2554
2555 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2556 must be replaced by calles to MWriteAsciiFile::AddColumn and
2557 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2558 changed.
2559
2560 - Implemented generalized event-matrices (one row per event)
2561 (MHMatrix)
2562
2563 - implemented the one dimensional composite probabilities
2564 (MHCompProb, MCompProbCalc, comprob.C)
2565
2566 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2567 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2568
2569 - Added a camera display displaying the pixel numbers to the
2570 event display gui.
2571
2572 - Added Monte Carlo Informations to event display gui
2573
2574 - Changed the camera display to display the pixel numbering
2575
2576 - Added three buttons to the camera display to change the palette
2577
2578 - Added the number of used and core pixels after image cleaning
2579 to MHillas
2580
2581 - Changed the algorithm used in MHillas according to TDAS 02-03
2582
2583 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2584
2585 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2586
2587 - Added fCosDeltaAlpha to MHillasSrc
2588
2589 - The numbers of photons used to calculate fConc and fConc1 in
2590 MHillasExt are now scaled with the pixel size, so that one get
2591 a four times smaller value for the bigger pixels in the outer ring.
2592
2593 - added new task to smooth the camera contents (MCameraSmooth)
2594
2595 - added possibility to use interpolated pixel values for blind pixels
2596 instead of removing it completely from the analysis
2597
2598 - Implemented the possibility to save the whole eventloop with
2599 its setup to a file. This information can be read and from
2600 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2601 and MEvtLoop::MakeMacro. If you find something not working, please
2602 report - this stuff is still in a beta phase.
2603
2604 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2605 file having crab starfield, but also for all following files - fixed
2606
2607 - MTaskList::PrintStatistics can now be instructud to print also the
2608 title, too: use PrintStatistics(0, kTRUE)
2609
2610 - Changed the image cleaning so that pixels with to many 'used'
2611 neighbors are left used (to get rid of 'holes' in events)
2612
2613 - Introduced more output to the camera displays
2614
2615 - Added an array of histograms (eg one hist per run), MHArray
2616
2617 - Added a _preliminary_ version of the reader for CT1 PreProc files
2618 (MCT1ReadPreProc)
2619
2620 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2621 (thanks to Raquel)
2622
2623 - added the first energy estimator (MEnergyEstParam, estimate.C,
2624 estfit.C) using a parametrization
2625
2626 - Added some new Monte Carlo paremeter containers used to store
2627 setup information from the MC chain (MMcConfigRunHeader,
2628 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2629
2630
2631
2632 *** Version 0.7 (2002/04/30)
2633
2634 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2635 the pedestal mean value was saved incorrectly. For files from
2636 this versions we substract 0.5 from the pedestal mean.
2637 WARNING: This may effect your results, so don't wonder...
2638
2639 - First implementation of an algorithm using only triggered events
2640 for the collection area calculation
2641
2642 - Ascii Output can now also be used for parameter containers which
2643 doesn't overload MParCointainer::AsciiWrite
2644
2645 - The Ascii Output is now also capable of writing single data members
2646 of one container
2647
2648 - You are now able to change the order of the values written to the
2649 ascii file
2650
2651 - You can now specify a conversion factor for each data member written
2652 to an ascii file. This may be usefull to change the units of the
2653 data member (eg. degrees instead of millimeters in case of the
2654 hillas parameters)
2655
2656 - Replaced old MHillas by a new structure which allows you to extend
2657 the parameters stored in MHillas very easily:
2658 see MHillas and MHillasExt
2659
2660 - Added classes to handle source dependancy of image parameters:
2661 see MHillasSrc
2662
2663 - Added container (MBinning) to have a standard input for the binning
2664 in different histograms (eg. the Energy bins should be the same in
2665 all histograms)
2666
2667 - Changed Hillas histograms from mm to deg
2668
2669 - Added the flexible binning to the hillas histograms
2670
2671 - Added a filter for the alpha parameter (MFAlpha)
2672
2673 - It is now possible to write single data members of a class object to
2674 an output stream instead of the whole container only
2675
2676 - Added a generalized filter for a data member:
2677 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2678
2679 - Added a generalized Filter parser for more difficult filter rules
2680 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2681
2682 - Added new Monte Carlo histograms:
2683 MHMcEnergyImpact and MHMcEfficiency
2684
2685 - Added many new histograms needed for the flux calculation.
2686
2687 - Added a generalized histograms which can fill and show up to three
2688 data members in either a one-, two- or three-dimensional histogram, eg:
2689 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2690
2691 - Added:
2692 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2693 * calculation of <Theta> as a function of time (MHThetabarTime)
2694 they are needed in the flux calculation in
2695 order to select for a given bin in Theta (or time) the appropriate
2696 effective collection area, which is assumed to be given as a function
2697 of Theta and the true energy
2698
2699 - Added calculation of the migration matrix in the energy
2700 (MHMcEnergyMigration):
2701 the migration matrix describes the migration from the true (E_true)
2702 to the estimated energy (E_est); it is needed to determine the
2703 distribution of E_true from the measured distribution of E_est
2704 by unfolding
2705
2706 - changed the color palette in the camera display to DeapSea.
2707
2708
2709
2710 *** Version 0.6 (2002/01/15)
2711
2712 - Introduce the option of disable pixels (MBlindPixels and
2713 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2714 able to deal with Star Field NSB.
2715
2716 - Fixed a bug in the pedestals substraction
2717
2718 - Introduced verbosity levels
2719
2720 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2721
2722 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2723 work correctly (thanks to Abelardo)
2724
2725 - Introduced correct treatment of the diffuse Night Sky Background
2726 and NSB (MMcPedestalNSB)
2727
2728 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2729
2730 - Introduced MMcRunHeaders which contains monte carlo run informations
2731
2732 - Added a 'Print'-Task (MPrint) which calls the Print function
2733 of a parameter container for each event
2734
2735 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2736
2737 - changes to be more efficient with root 3.02/06
2738
2739 - root 3.02/06 fixes:
2740 + the memory leak when reading MRawEvtData
2741 + loosing more time than necessary to update the progress bar
2742
2743 - MWriteAsciiFile is now capable of writing more than one container
2744 in a line. For example: To be able to write Monte Carlo and
2745 Hillas values (energy and alpha) in one line.
2746
2747
2748
2749 *** Version 0.5 (2001/11/06)
2750
2751 - Added new GUI functionality (Analysis)
2752
2753 - Added a camera display to be able to display events in the camera
2754 together with the calculated hillas ellipse
2755
2756 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2757 object at any state of the analysis, so that the output are several
2758 states
2759
2760 - Fixed a bug in the collection area error calculation
2761 (Thanks to Ciro and Abelardo)
2762
2763 - Fixed a bug which causes merpp to crash in some environments
2764
2765 - Implemented auto enabling scheme for Branches to speed up reading
2766 a lot (see MReadTree and MTask)
2767
2768 - Fixed a bug in the Histogram classes which caused histograms to
2769 be written to a file by MWriteRootFile without request
2770
2771 - changed the object I/O from the old stylish root I/O to the new
2772 'auto evolution scheme' This was done only for classes which are not
2773 yet used in Monte Carlo files, so that these files are still readable.
2774
2775 - Added support for a progress bar in MEvtLoop and MReadTree
2776 (see the Analysis Window in Mars for an example)
2777
2778 - Fixed a bug in the package creation which disturbed the conversion
2779 between a mars version unpacked from a tar file and the repository.
2780
2781 - Changed the code to writer merpped (converted into root format)
2782 raw files, to get faster (around 10%)
2783
2784
2785
2786 *** Version 0.4 (2001/09/20)
2787
2788 - This release is made to compile on a root version >= 3.00
2789
2790 - Fixed a bug which causes MReadTree to read the first file only
2791
2792 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2793
2794 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2795
2796 - Added a task to write several container to a root file (MWriteRootFile)
2797
2798 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2799
2800 - Added calculation of the collection area (MMcCollectionAreaCalc)
2801
2802 - fixed some bugs in the Hillas calculation
2803
2804 - added filters to be able to control the task execution dependent on
2805 a parameter (for example: the number of level 1 triggers in a MC-file)
2806
2807
2808
2809 *** Version 0.3 (2001/04/23)
2810
2811 - Many demo macros added
2812
2813 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2814
2815 - Hillas Calculation added
2816
2817 - Standard image cleaning available
2818
2819 - MReadTree is now able to handle more than one file
2820 (Remark: of the same structure)
2821
2822 - Now we are able to display events in a first version of the
2823 Camera event display. To do this we must run the macro
2824 "macros/readCT1.C" to read data from CT1.
2825
2826
2827
2828 *** Version 0.2 (2001/01/24)
2829
2830 - First Implementation of a Gui to read the raw data. Start the
2831 gui with the command mars.
2832
2833
2834
2835 *** Version 0.1 (2000/12/20)
2836
2837 - First official release 0.1
2838
2839 - Changes:
2840
2841 + changed calling style of MRawPixelIterator from do...while to
2842 while-loop
Note: See TracBrowser for help on using the repository browser.