source: trunk/MagicSoft/Mars/NEWS@ 9296

Last change on this file since 9296 was 9296, checked in by Daniela Dorner, 16 years ago
*** empty log message ***
File size: 127.9 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;merpp
6
7 * added support for Arehucas Version >= 200812140
8
9 ;database
10
11 * plotdb.php: added default (sequences) for startup, added possibility
12 to set size of plot
13
14
15
16
17== Version 2.2 (2009/01/30) ==
18
19 ;SUGGESTION
20
21 * This release doesn't contain a major change which is expected to
22 change your results. Nevertheless there are small changes to
23 the calibration which can effect at least the first few hundred
24 events in any (mainly MUX and even more SUM) sequence a little bit.
25 So it is recommended although not necessary to reset your sequences
26 in the database before further processing.
27
28 ;NEW
29
30 * A first implementation of a Monte Carlo simulation program
31 (ceres - Camera Electronics and REflector Simulation) has been
32 implemented. It can simulate a full telescope already including
33 a complete reflector simulation and a flexible trigger and readout
34 simulation. Currently, no perfect setup is implemented and
35 especially the output of the program (data structure) should
36 be considered alpha state. Also the user interface is not yet
37 ready.
38
39 ;general
40
41 * All command line options after -- are now interpreted as
42 arguments (usually everything which doesn't start with a minus)
43 rather than options (usually everything which starts with a
44 minus). This allows to use file names starting with a -
45
46 * In all resource files you can now initialize the random number
47 generator. For details see: MJob::InitRandomNumberGenerator
48
49 * added a new program called ''readcorsika''. It's purpose is (in analogy
50 to readraw and readdaq) to read a Corsika output file (for now
51 only cherenkov output is supported) and print its contents in a
52 human readable form. It can also write the contents of this file
53 into a root-file.
54
55 * The calculation of the maximum distance to the origin in a MGeomCam
56 has been improved (edges might be further away than the sides).
57 This is just a tiny change but it might change the appearance of
58 the radial profiles a little bit.
59
60 * The default binning of the center-of-gravity plot has slightly been
61 increased
62
63 ;Database
64
65 * Added informations about the DC currents (fMinCurrents, fMedCurrents
66 and fMaxCurrents). The values are retrieved from the plots showing
67 the average DC currents of all pixels versus time.
68
69 * Websites with tables have now the opportunity to remove lines
70 ('-' button at beginning of each line) and get all lines back
71 ('+' at top of the column)
72
73 * Websites: added option to query only sequences containing sumtrigger
74 events
75
76 * Websites: added option to group by date (year, month, night) for runs
77 and sequences and enabled that combining of different group-bys,
78 e.g. status, date and source is possible
79
80 ;automatic analyis
81
82 * Rewritten producing plots in the web.
83 New plots, namely the output of plotoptical.C (extinction curve from
84 KVA), plotstat.C (status of the automatic analysis (percentage of
85 processed, analysed data etc.)) and plotusage.C (statistics of the
86 condor usage in the data center) has been are available now next to the
87 plots of plotdb.C
88 Mean values from the plots (output of the macro) are provided in a
89 txt file now.
90 The creation of the plots for callisto, star and ganymed in the web is
91 now steered via database. Consequently the plots are faster and
92 reliable up-to-date.
93 For all plots, a new layout is available facilitating the browsing
94 through the plots and providing additional information on the
95 displayed values. (tabs.php) These plots are linked from the DB
96 websites and the wiki.
97
98 ;statusdisplay
99
100 * The ''Loop'' entry in the menu bar now contains an option to pause
101 the loop and to process single events.
102
103 ;merpp
104
105 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
106 instead of RunHeaders)
107
108 * Now allows to merpp files newer than 2008/09/03.
109
110 * Added fixes for wrong (wrong or double) run- and file-numbers
111 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
112
113 ;callisto
114
115 * Extracting the pulse position for the pulse position check events
116 with sum trigger were denied. This decreased the statistics
117 extremely and therefor the resulting puse position was calculated
118 quite weak. Now sum events pass the calculation if and only if they
119 have also a level 1 trigger.
120
121 * the extraction of pedestal events and pulse position from the
122 first data events is now more automatic and makes sure that
123 a more precise number of events is extracted independent of
124 the ratio with which pedestal events or events with signals
125 are contained in the data.
126
127 * Updated Muon calibration constants for all MUX data (teh changes were
128 all smaller than 5%)
129
130 ;star
131
132 * For the calculation of the effective on time all sum-triggered events
133 were skipped. Now all Level1-triggeres events will pass. This might
134 result in a slight inaccuracy of the effective on time.
135
136 ;ganymed
137
138 * If the source position is more than 1deg away from the camera
139 center an error is raised now.
140
141 * Hopefully fixed the bug ''ganymed crashes when resized''
142
143 ;sponde
144
145 * Fixed a problem which causes the fitted spectral slope to be displayed
146 incorrectly. If you use MJSpectrum::FormFlux in your macros make
147 sure that the parameter 0 of your fit is negative.
148
149 * Added a histogram showing the read source position of your MCs
150
151
152
153== Version 2.1.1 (2008/08/04) ==
154
155 ;Database
156
157 * Added the median number of photo electrons from the calibration
158 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
159 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
160
161 * Added fTotOnTime, which is the on-time as given by the run-headers
162 (in contradiction to fAbsOnTime which comes from CC)
163
164 * Added new primaries for the new data structure (Magic II): for the
165 tables dealing with sequences (SequenceBuild Status, Sequences,
166 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
167 this is the telescope number (fTelescopeNumber) for the tables dealing
168 with runs (RunData and RunProcessStatus) this is in addition the file
169 number (fFileNumber)
170
171 * Added column fPriority to the status tables to be able to steer the order
172 in which the data is processed. As default the run, sequence and dataset
173 number are used.
174
175 ;automatic analyis
176
177 * Adapted scripts to the new data structure: They can handle now different
178 telescopes (getting the information as usual from the database).
179 The paths for Magic 2 are not yet implemented.
180
181 ;general
182
183 * should work now with root 5.20/00 (please note that root 5.20/00
184 we encounter crahses in the status display which are ot yet
185 understood)
186
187 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
188 instead of the base name of the file. This makes them easier to
189 access from the code
190
191 * Default Monte Carlo names in MSequence do not require the _E at
192 the end anymore
193
194 * where abrrevating a sequence file with a sequence number is possible
195 also "telescope:sequence" is now accepted, e.g.:
196 star 2:2000123 --out=output
197 see the programs' help for more details.
198
199 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
200 from the database. See the constructors for more details.
201
202 * MReadTree now supports friends
203
204 * MReadTree can now read also files not written by MARS and store
205 the data encapsulated in emulated MParContainers
206
207 * added a new starguider calibration valid since 15.1.08
208
209 ;showplot
210
211 * showplot can now read more than one file at once. This is especially
212 inetersting if reading files containing pure canvases
213
214 ;merpp
215
216 * we merpp the dc currents now also from the camera reports (they have
217 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
218
219 * In the automatic analysis we omit merpping of the currents from the
220 caco files and use the lower rate camera reports from the cc files
221 instead
222
223 * merpp has been redisigned to allow merpping of the cc-reports
224 of a whole sequence. This allows to design a very simple analysis:
225 mkdir output
226 ./callisto 100776 --out=output
227 ./merpp 100776 output
228 ./star 100776 --ind=output --out=output
229 Instead of the sequence number also sequence files are accepted.
230
231 * Implemented a fix for run-numbers between 1001348 and 1001396
232 which were incorrectly assigned by the cc.
233
234
235 ;callisto
236
237 * added a filter again which was was removed in the last release.
238 it removed the most brightest events. This should not change
239 any analysis result because these events are so bright that
240 they cannot be analysed anyway, but the bad-pixel plots doesn't
241 show outliers.
242
243 * updated muon calibration constants for the periods 51-57,
244 58-63 and 67-
245
246 ;star
247
248 * The camera currents are now displayed with the rate of the camera
249 reports instead of the caco reports
250
251 ;ganymed
252
253 * if mc camera files are new enough (>=8) the source position in the
254 camera is now calculated from the stored telscope and shower
255 orientation (Note, that this might not be suitable in all cases
256 depending on the aim of the study. These case still needs
257 implementation)
258
259
260
261== Version 2.1 (2008/06/18) ==
262
263 ;Database
264
265 * introduced average temperature and wind speed from star-files
266
267 * introduced average values from Pyrometer (mainly Cloudiness)
268
269 * introduced the ratio of accepted calibration events in the
270 calibration run
271
272 * introduced the average rates of the different trigger pattern,
273 e.g. the rate of pedestal and calibration events, from the signal-file
274
275 ;general
276
277 * fixed GroupBy options in plot*.C macros
278
279 * only display KVA points (not the Tuorla points) in plotoptical.C
280
281 * all programs now allow to add resources to the ones from the resource
282 file or overwrite them from the command line. This can be done like this
283 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
284 if something seems to be wrong you can debug what the program is doing
285 using the option --debug-env=3
286
287 * increased the diversity of debug levels. That also means that with -v3
288 you get now less output, i.e. only the output which is important for
289 an analysis. To get more output which helps for debugging try 4, 5 and 6.
290
291 * fixed a problem in the task synchronizing the reading of the reports
292 and the data stream. The effect was that in some circumstances the last
293 events of some trees could have been skipped. Since this is only a
294 very tiny part of the data no severe effect to your analysis results
295 is expected (an exception might be very short, i.e. singel runs,
296 datasets).
297
298 * Dataset file now allow to include the sequence file directly within
299 the dataset file and also allow to exclude single runs from the dataset.
300 (for more details see Class reference of MDataSet)
301
302 * Sequence files now allow for excluding runs from the analysis
303 (for more details see Class reference of MSequence)
304
305 * added code to process the sum-trigger flag
306
307 * the histogram classes MH3 and MHn now support profile histograms
308
309 * the histogram classes MH3 and MHn now support labels at the axis
310
311 * the Random Forest Train-classes (MJTRain*) now store the used datasets
312 in the output file
313
314 * the MFMagicCuts have a new option to allow a linear area cut (for
315 special studies)
316
317 * The liniking of the shared object is now done into a file defined
318 by 'mktemp'. This should be a local file system which accelerates
319 liniking a lot.
320
321 * The code has been prepared for compilation with root 5.18/00d
322
323 * The MHEnergyEst histogram now shows the distribution of
324 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
325 and (Eest-Emc)/Emc vs Emc.
326
327 * fixed mars (event display) for merpped raw-data and MC data
328
329 * adapted the synatx of sequence files to allow for the new run/file
330 scheme. For more details see class description of MSequence
331
332 ;showplot
333
334 * Added support for tiff files
335
336 * Added support for csv files (tables containing tab number,
337 name and title)
338
339 * Tabs now can have a title which is displayed in the postscript file
340
341 * When multiple file are written at once (e.g. pngs from a display)
342 it is now possible to use the tab name and or tab number in the
343 file name. For details see showplos's help.
344
345 ;merpp
346
347 * Implemented cc file version 2008-02-20/0
348
349 * Implemented cc file version 2008-05-19/0
350
351 * With new options merpping can be restricted (in addition to the
352 run-number) also by telescope and file number.
353 For details see "merpp --help"
354
355 * Implemented raw data format 11 (the most important change, except
356 from plenty of changes in the format definition, is the addition
357 of the file-number in the header) If nobody makes a mistake this
358 format should have the advantage that it is by definition forward
359 compatible, so old programs will be able to read newer formats.
360
361 * Added Pyrometer information to default output (stored in a new Tree
362 Pyrometer, needs a complete new merpp, i.e. new calibration)
363
364 * Merpping (also update) can now be restricted to one single report.
365 For example:
366 If you want to update an old file with Pyrometer information call
367 merpp --only=Pyrometer --update
368
369 ;callisto
370
371 * in the pedestal processing now at least 50 processed events are
372 required for succeeding.
373
374 * the signal and calib files now contain also the sequence information
375
376 * the two MPedestalCam in the calib file now have proper names
377 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
378
379 * Both pedestal cams now contain the number of events processed
380
381 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
382 i.e. for the extraction of the calibration pulses basically the average
383 over all events of the first slice instead of all slices was used.
384 Since pedestal and calibration constants are continously recalculated
385 this only effected the very first events of every sequence.
386
387 * For the extraction of the position of the maximum sample now the
388 extraction range is set automatically to the extraction window,
389 before the whole accessible range was used.
390
391 * If the number of samples in the events and the number of samples
392 in the run-header disagrees now an error is raised (this can
393 happen in not well simulated Monte Carlo files)
394
395 * In the case of MUX-data pedestal events with the lvl1 trigger flag
396 could survive into the pedestal calculation -- fixed.
397
398 * Tab "TrigPat" added showing the distribution of the trigger pattern
399 as found in the run-files (normalized with the run length)
400
401 * The selection of events from the trigger pattern has been improved.
402 If the trigger pattern is corrupted events won't pass anymore.
403
404 * Added a new command line option --dev-null to suppress output of
405 Y-files (this is useful for test cases)
406
407 * added a new tab "CalPos" showing the arrival time of extracted
408 interleaved calibration events
409
410 ;star
411
412 * the star file now contains also the sequence information
413
414 * Added a new command line option --dev-null to suppress output of
415 I-files (this is useful for test cases)
416
417 * Tab "Rate" added showing the distribution of the trigger pattern
418 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
419 the Y-files (normalized with the run length)
420
421 * The effective on-time calculation doesn't use events with only
422 sum-trigger anymore
423
424 * The data in the MHWeather tab has been reorganized. The never
425 working solar radiation has been removed and the data from
426 the pyrometer (cloudiness, air and sky temperature) is
427 displayed in addition.
428
429 ;ganymed/sponde
430
431 * Now data points are even shown correctly if they have error bars larger
432 than one sigma. Points with null or negative significances are omitted.
433
434 * DrawNicePlot now allows to set a projection range
435
436 * Updates pointing models. One is applied after the implementation
437 of the new LUTS in August, the other one is applied after the
438 next major change of the pointing model in October. Note that
439 these models are preliminary and give wrong results below Zd=65deg
440
441 ;sponde
442
443 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
444
445 * a new option "--force-runtime" is available. In case of very short
446 datasets (for light-curves) which are in the order of a few
447 minutes the calculated effective on-time is not very acurate because
448 it is quantizised in the order of a minute. Therefore you can switch
449 to using the real run-time instead (remakrt: this ignores any
450 dead-time!)
451
452 * a more analytical way is used to "fill" Monte Carlos into regions
453 of impact parameters which have not been simulated because the
454 trigger efficiency is assumed to be 0.
455
456 * estimated sensitivity curves for hi and lo zenith angles are shown
457 scaled to the correct observation time and collection area
458
459 * the Monte Carlo events after cuts are now written to the output file
460 if an output file given
461
462
463
464 *** Version 2.0 (2007/09/03)
465
466 - database: the position used for the pulse pos check was missing
467 in the callisto output and could thus not be filled into the DB.
468 Also the old values seemed not exactly the PulsePos used for
469 teh check.
470
471 - general: Resource file now allow an Include-Resource, i.e. you can
472 read a resource file with default settings, include it in your
473 resource file and overwrite the settings in your file. More than
474 one include file is allowed. Inclusions can be iterative.
475 Include: mydefaults.rc yourdefaults.rc
476 The resources in the first file have higher priority than the
477 second file.
478
479 - general: Now the output files (calib*.root, etc) also contain the
480 resource file (to check it open it in the TBrowser and choose Print()
481 from the context menu)
482
483 - general: Dataset files now allow to overwrite the default path
484 to search for sequence and data files. Note, that the program
485 option and individual resources will overwrite it. For example:
486 SequencePath: /magic/montecarlo/sequences
487 DataPath: /magic/montecarlo/star
488
489 - general: Fixed a problem with variables in MDataPhrase. It seems
490 that only optimdisp (didn't work) was effected.
491
492 - general: Some improvements to the optim and train processing. For
493 example the ststud window now got a proper title.
494
495 - general: The "Status Display: " was removed from the window title
496 within an Eventloop.
497
498 - general: added a new flexible histogram-class (MHn) which can be used
499 for example in testing after optimizations or training to produce
500 user defined histograms.
501
502 - general: The Random Forest now allows attaching an evaluation
503 function which is applied to its output. This allows to train
504 on whatever you like (eg. train on log10(energy), but return
505 energy)
506
507 - general: The Random Forest training of energy (trainenergy.c) and
508 disp (traindisp.C) has been improved by more graphical output to
509 judge the result.
510
511 - general: The training of energy (trainenergy.C) has been improved
512 a lot by training on a different quantity than energy. It gives
513 a result which is highly independant of the source spectrum
514 and shows lower bias than all other options.
515
516 - general: Dataset files are allowed to contain collections of
517 datasets. For more details see the class reference of MDataSet.
518
519 - general: The default WobbleMode in a datset file now (if not
520 overwritten) is "auto", i.e. wobble mode is set if the dataset
521 doesn't contain off-sequences.
522
523 - merpp: Merpp can read file format version 9 now. Please realize
524 that for file format version 9 the extraction range is different
525 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
526 the first and last 15 slices have been removed from all MUX data.
527
528 - mars: Similar to writing movies you can now select events which
529 should be displayed in your display. Therefore add the following
530 lines to your mars.rc:
531 MFEvtNumber.FileName: ganymed00223552.root
532 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
533 The input file can be a ganymed-file after (ganymed*.root) or
534 before (ganymed*-summary.root) file. For example to select all events
535 from your on sample after cuts (excluding the ThetaSq cut) use
536 MFEvtNumber.Selector: DataType.fVal>0.5
537 To show all events from your on-sample after quality cuts
538 use the summary file instead.
539
540 - mars: new ways to call mars are implemented. Instead
541 of calling
542 mars filename.root
543 you can now also use
544 mars sequence.txt
545 or
546 mars sequence.txt inputpath
547 or replace sequence.txt by the sequence number if the default
548 sequence file should be used.
549
550 - mars: The default size has been increased
551
552 - mars: There are two new heckboxes which allow to switch off
553 the calculated image parameters
554
555 - callisto: was broken for MCs... fixed.
556
557 - callisto: improved calculation of spline coefficients a lot. This
558 leads to a further improvement of the event rate calibrating MUX
559 data of about 15% (175evt/s instead of 150evt/s)
560
561 - callisto: finally the raw data we read is now real 16bit (with
562 10bit precision) for MUX data and not a stripped 8bit number
563 anymore. Due to scaling of the numbers (without precision loss
564 into an [0-256[ range, the final numbers for pedestal, pedestalrms
565 and extacted signal don't change. However, at all places where
566 raw data is directly accessed (eg. saturation and variation
567 limits in the signal- and pedestal-extraction) the numbers
568 refer still to the data's 16bit range.
569
570 - callisto: The maximum arrival time difference used in the bad
571 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
572 for both, old FADC and MUX-FADC, data.
573
574 - callisto: Be aware that callisto is now calibrating the arrival time
575 in nanoseconds rather than time slices. Also all following tasks
576 have been changed to assume ns units now. If you star data
577 calibrated with an older version it might be necessary to adapt
578 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
579 to obtain optimal results. The plot in the PulsePos tab
580 will now be in ns, too. This might also mean that the Muon
581 analysis in star might not work as perfect as expected as long
582 as old files read in.
583
584 - callisto: The calibration constants of earlier updates got lost
585 somehow. All constants have been updated.
586
587 - star: The PSF is now determined from the profile of the ArcWidth
588 instead of arcwidth/radius. The old way gave to much weight
589 to the bins with low statistics. The reference lines have been
590 updated.
591
592 - star: For speed reasons events suitable for the muon analysis
593 are now also preselected by fConcCOG<0.1 which seems to be a very
594 good preselector for muons.
595
596 - star: is now calculating a new timing parameter the Slope along
597 the major and minor axis of the shower. Therefore a numerical
598 solution of a line-fit is used. To use MHillasExt.fSlopeLong
599 and MHillasExt.fSlopeTrans don't forget to multiply it with
600 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
601
602 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
603 have been removed from MNewImagePar. They have never been good for
604 anything.
605
606 - star: Implemented a new recursive algorithm which is supposed to be
607 faster. Also implemented new cleaning oiptions, which are:
608 + CleanLevel0:
609 The cleaning level above single core pixels can be kept
610 + KeepIsolatedPixels:
611 Define whether single core pixels should be kept
612 + TimeLevel1:
613 The coincidence window in nanoseconds to single used neighbors
614 + TimeLevel2:
615 The coincidence window in nanoseconds to two used neighbors
616 + PostCleanType:
617 MOde in which a time dependent post cleaning should be applied
618 0: No post cleaning
619 1: Require for each used pixels at least one used neighbor
620 within a time-window of CleanLevel1
621 2: Require for each used pixels at least two used neighbor
622 within a time-window of CleanLevel2
623 3: Require first two and second one used neighbor
624 within a time-window of CleanLevel1 and fCleanLevel2
625 respectively
626 + RecoverIsolatedPixels:
627 - recoveres isolated core pixels if they have a used neighbor
628
629 - mars/star: The new default cleaning is:
630 + CleanLevel1: 6.0
631 + CleanLevel2: 3.0
632 + CleanTime1: 1.75
633 + CleanTime2: 1.75
634 + PostCleanType: 3
635
636 - star/ganymed: The old spark-cuts have been replaced by new ones.
637 These new spark cuts have been cross checked with the sequences
638 84720 (before splitter), 101041 (after splitter) and 223539 (new
639 FADCs). In all cases they seperate pretty well, but of course not
640 perfect. Monte Carlos have suggested to tighten the cuts a little
641 bit further at low sizes. This has been done.
642
643 - ganymed: IMPORTANT - The spark cuts have been changed to match
644 all available data more or less well. This might mean that for
645 YOUR data there are still sparks visible.
646 Whenever you do an analysis you have to make sure that NO sparks
647 survive your cuts!
648
649 - ganymed: The old hadronness and size cuts have gotten new indices
650 (10, 11). The old indices 8 and 9 now mean an additional condition
651 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
652 If you want to switch off this cut just move the line far away enough,
653 e.g. by setting c[9] to -500. Please update your ganymed.rc files
654 accordingly!
655 The unit of c[9] is deg. It is the dist at which your cut will
656 cross the slope==0. The unit of the slope is ns/deg. So if
657 you readin files calibrated with an older Mars-version you
658 have to adapt the default value for c[9] to the FADCs:
659 - Multiply by two for the MUX FADCs (run number > 200.000)
660 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
661 - Multiply by 42 for the meaning of life (run number = 200.000)
662
663 - ganymed: The old Cut0 is now called CutQ and is calculated before
664 the source position is caluclated. If you need a quality cut
665 including source dependant data (be very carefull with this!)
666 you have to use Cut0 instead.
667
668 - ganymed: now properly supports three off regions in wobble mode.
669 It will be the default from now on in ganymed_wobble.rc. To change
670 the number of off-regions use
671 NumOffSourcePositions: 1
672 in your ganymed.rc. Also by default no off-theta cut will be done
673 anymore so that you will get a background level higher than the
674 signal level in your ThetaSq plot for ThetaSq>0.2.
675 Due to this be carefull changing the scaling mode away from
676 "None". You will underestimate your signal if your scale interval
677 is not properly set.
678 (Rem: ThetaSqN is no longer needed)
679
680 - ganymed: is now storing the events of all (on- and off-)
681 source positions even in the case of more than one off-source
682 position. This should allow sponde to work properly and the
683 energy estimation is done correctly in all cases (without any
684 "nearest position" trick)
685
686 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
687 with a real pointing model for the starguider is done, calibrated
688 with more than thousand tpoints taken from this date on.
689
690 - ganymed: was broken for Wobble-MCs... fixed.
691
692 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
693 has changed. Note that your old ganymed.rc will be incompatible
694 with the new algorithms! Please check the ganymed.rc files and
695 the class description of MFMagicCuts for more information.
696 It is recommended at the moment to use identical Disp-Parametrizations
697 for on/off- and wobble-mode. If cuts are optimized only
698 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
699 should be optimized. All other values should be kept as they are.
700 If you want to do an anylsis without timing a parameters, you can
701 switch off the timing cuts by seeting parameter 7 to a very small
702 value (eg. -99). To remove the slope parameter from the disp
703 paremtrization set parameter 8 to 0.
704
705 - ganymed: The distribution of observation time versus zenith
706 angle is now shown for off- AND on-data.
707
708 - ganymed: The contents of the source position plot are no longer
709 averaged, thus a lot of (fake) events between the two wobble
710 positions have disappeared.
711
712 - ganymed: There is a new tab "CutT" it contains the VsSize plots
713 with the CutT, whihc is defined in ganymed.rc, applied. It
714 is resonable to use your theta-cut for it, to see if there is
715 something strange (sparks!) in your signal-region.
716
717 - ganymed: To choose a dataset from a collection in a dataset file
718 use the new command line option "--dataset=12345"
719
720 - optim, sponde: should now properly support three off-regions.
721 Just produce your ganymed summary files with three off-regions.
722 optim and sponde will automatically get all off events from
723 all off-regions from this file. Please do not forget to
724 set the scaling in optimwobble.C properly:
725 fit.SetScaleUser(1./3);
726 it is not yet read in automatically (will follow soon).
727 In the case of fixed Scale you can also use
728 cuts.SetThetaCut(MFMagicCuts::kOn);
729 no off-cut needed.
730 Be carefull in case of three off-regions when switching on
731 scale mode. Make sure that the scale interval is set correctly.
732
733 - sponde: sponde.rc and sponde_onoff.rc are now idetical
734
735 - sponde: the resouce files have been rewritten with a lot of
736 comments and a well working parametrization for an energy estimator
737
738 - sponde: In the estimated energy versus monte carlo energy plot the
739 contents where exchanged.... fixed.
740
741 - sponde: the so called "accurate"-mode has been removed. It didn't
742 give any improvement in accuracy, only decreased execution speed.
743
744 - sponde: the so called "simple"-mode has been removed. It didn't
745 give any improvement in simple.
746
747 - sponde: the so called "refill"-mode has been removed. It was anyhow
748 not implemented.
749
750 - sponde: now checks whether the theta distribution of your on-data
751 and the theta-distribution of your Monte Carlo sample (after
752 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
753 sample is incomplete) execution is stopped. Execution can be forced
754 using the new option --force-theta. Use this option with care!
755
756 - sponde: Proper collection areas can now be constructed also from
757 Monte Carlo samples generated with different maximum impact
758 parameters. Note that in previous version you neither got
759 a warning or failure, nor was there any obvious sign that the
760 collection area was overestimated due to usage of files with
761 different maximum impact parameters.
762
763 - sponde: If MC files with different lower energy limits are used
764 the primary MC spectrum is artificially completed down to the
765 lowest energy used at all. WARNING: that this gives correct
766 collection areas ONLY if none of the events in this region would
767 survive your cuts at all.
768
769 - sponde: the output file now contains more information about
770 the spectrum (eg. the full 2D collection area histogram).
771 Note, that this information can only be written to the file
772 if it is stored automatically via command line argument.
773 If you only store the status display from within the display
774 the information is lost.
775
776 - sponde: added a new tab "Disp". It shows the residual of the disp
777 (Disp-Dist) versus several parameters and it is meant to judge the
778 quality of the disp estimator. In the ideal case the residual is zero
779 and doesn't depend on any variable. The tab is displayed after
780 CutQ and Cut0.
781
782 - sponde: added a new tab "Energy". It shows the residual of the
783 energy (lg(estimated energy)-lg(monte carlo energy)) versus
784 several parameters and it is meant to judge the quality of the
785 energy estimator. In the ideal case the residual is zero
786 and doesn't depend on any variable. In reality even a good estimator
787 can show residuals versus Monte Carlo energy. The tab is displayed
788 after all cuts.
789
790 - sponde: added a new tab "EventDist" showing the unweighted real
791 absolute number of events of your sample after cuts. This tells
792 you how many events with this energy you had in your MC files.
793 The same information you get from the error bars of the weighted
794 histograms, but this is less intuitive.
795
796 - sponde: The spectrum plots now show the crab- and 1553-spectrum
797 for comparison. It is not meant to show these curves in
798 publications, they are only for production.
799
800 - sponde: The OriginalMC tree with the events produced by corsika
801 is now processed only once
802
803 - sponde: Finally fixed most annoying bug, which has effected the
804 last bin of the collection area. It was the problem that binnings
805 of root histograms are from 1 to n (included) but there was a C-like
806 loop in sponde from 0 to n (excluded). Now the loop also includes
807 correctly under- and overflow-bins. The worse thing with this is,
808 that for the events in the highest bin not only the bin-content
809 was wrong, but also the weights applied to these events, which could
810 in pricipal effect also other parts of the distribution (eg. due
811 to energy estimation). Fortunately it effected only a few events
812 in most cases.
813
814
815
816 *** Version 1.2 (2007/05/14)
817
818 - database: The database now has two new values Unsuitable50 and
819 Unsuitable01. They express the number of pixels which are
820 unsuitable for more than 50%, respectively more than 1%, of
821 all calibrated event. It is a more accurate number than the
822 previously used numbers, because they only take the first
823 calibration (ignoring the interleaved calibrations) into account.
824
825 - database: The database now has two other new values UnsuitableMax and
826 DeadMax. They express the maximum number of pixels which were
827 unsuitable, respectively dead, during the sequence. Because
828 of high pedestal rms (cars passing) a few events with very high
829 numbers of unsuitable pixels can happen. Not to suffer from this
830 effect we don't take the highest 0.1% of the numbers into account.
831
832 - general: fixed a bug which caused callisto and star to stop working
833 properly because the callisto output was currupted
834
835 - general: a script called scripts/makemovie has been added which
836 simplified the process of producing several movies from a single
837 sequence with different setup.
838
839 - callisto: Some more code cleanup. Started to remove old obsolete
840 code from cvs.
841
842 - callisto: The extraction of the pedestal with the extractor was
843 not random. It seems that extracting at one position is still biased
844 (for example in the first or last slices we could still suffer from
845 switching noise) Now it is completely random.
846
847 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
848 pedestal files) individual pixels could be skipped due to high
849 variations. This was already the case for the pedestal extraction
850 from the lo-gains since the beginning and properly handled
851 there, but was introduced in the extraction from the pedestal files
852 a while ago. To calculate the average value it was still divided
853 by the number of events procesed not by the number of summands
854 really summed. This let to a pedestal which was a tiny amount too
855 small (for a few piels in the order of 0.1%). This led to an slightly
856 positive offset of the randomly extracted pedestal for a few pixels.
857 I doubt that this has a big effect on the result, because the effect
858 on the individual numbers is quite small. Due to this it is suggested
859 that you rerun your calibration to make sure you are without any
860 avoidable bias.
861
862 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
863 the median rms of the absolute arrival time and expressed in significance
864 levels. This replaces the old meaning of an abolute upper limit. An
865 absolute upper limit doesn't make much sense, because in our data
866 all arrival times are shifted at the same time (in fact it might be
867 a shift of the artificial trigger w.r.t. to the light flash).
868
869 - callisto: Added a new tab "BadPixTm" which shows the time evolution
870 of the number of unsuitable pixels over the whole sequence. This
871 is usefull mainly to judge if an intermediate calibration had
872 problems.
873
874 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
875 of the number of dead pixels over the whole sequence. Dead pixels
876 in this context are unmapped pixels, i.e. pixels which could not
877 be interpolated, and thus are ignored in the further analysis.
878
879 - callisto: It is now possible to use the position of the maximum
880 of the spline as arrival time instead of the leading edge even
881 when using the integral for the signal. Therefor set the extraction
882 type to kIntegralRel ("IntegralRelative") and the relative height
883 ("HeightTm") to -1:
884 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
885 MJPedestalC1.ExtractSignal.HeightTm: -1
886
887
888
889
890 *** Version 1.1 (2007/04/27)
891
892 - general: The new class MGeomCamDwarf contains the camera geometry
893 for our prefered Dwarf camera and can be used to create general
894 geometries of roundish or hexagonal cameras.
895
896 - mars: The default cleaning is now abolute 8.5/4.0.
897
898 - mars: The resource file mars.rc now contains examples for MUX data
899
900 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
901 data containing only 10-bit information is still cooked down to
902 8-bit, by cutting away the lowest 8-bit.
903
904 - merpp: When reading raw data the data is now stored in a single
905 array. The lo-gain array is obsolete. The interface stays the same.
906
907 - callisto: To process the new MUX data use the resource file
908 callisto_mux.rc
909
910 - callisto: The -root and -raw options to read merpped raw data have
911 been removed
912
913 - callisto: If the -mc option is given the sequence-name can now be
914 replaced by the MC sequence number
915
916 - callisto: If the sequence file contains "MonteCarlo: Yes" the
917 -mc option can now be omitted
918
919 - callisto: Started further simplification by removing obsolete
920 dependancies on MCalibIntensity*Cams.
921
922 - callisto: removed unsused intensity calibration from MJCalibration
923 for further simplification
924
925 - callisto: for simplification removed references to
926 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
927 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
928 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
929 (this should at minimum change nothing at all, and at maximum
930 improve thing if these containers where somewhere not handled
931 properly)
932
933 - callisto: Added the option to write an event movie. Please use
934 this option with care (huge files) but exessively to understand
935 our events. For further documentation please refer to the
936 IACT wiki
937 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
938
939 - callisto: Improved binning for the pulse position check histogram
940
941 - callisto: The code calculating the pulse position checknow takes
942 the pedestal into account
943
944 - callisto: The arrival time is now stored with full precision this
945 helps to get rid of artefacts in histograms. For the signal this
946 is not necessray because it is displayed in log-scale anyhow
947
948 - callisto: Fixed a problem with internal exclusions. Pixels which
949 have once been marked as unsuitable didn't get the necessary
950 histograms filled anymore to be rechecked with each interleaved
951 calibration.
952
953 - callisto: The relative arrival time resolution (the rms of the
954 relative arrival time offset) is now checked against its
955 median and the median deviation, instead of the average
956 plus an absolute offset.
957
958 - callisto: The relative arrival time offset is now calculated
959 w.r.t. its median not w.r.t. to an artificial reference pixel.
960
961 - callisto: The relative time calibration now marks pixels with
962 outlaying offset as unsuitable
963
964 - callisto: The interleaved relative time calibration has been switched
965 on. The advantage is that pixels which are marked as outliers
966 now can recover. An improvement over time is not expected, because
967 the relative time calibration seems stable.
968
969 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
970 option can now be omitted.
971
972 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
973 or the option "-mc" is specified as default the monte carlo datacenter
974 paths (/magic/montecarlo/...) are used if not overwritten in the
975 dataset file.
976
977 - ganymed: The output files now contain run- and event-number for all
978 events, accessible as RunNumber.fVal and EvtNumber.fVal
979
980 - ganymed: Added a plot showing the source position in the camera also
981 for wobble mode
982
983 - ganymed: In addition to the existing task which can be setup to
984 be executed after Cut1 a final task called "EstimateEnergy"
985 has been added, executed before writing the final output
986 (ganymed00000000.root). The task setup in all three cases
987 can be choosen individually. (For all three(!) cases you
988 can for example choose MRanForestCalc. For examples see all
989 sponde*.rc and all ganymed*rc)
990
991 - ganymed: If a container "MEstimatedEnergy" is found in the
992 parameter list (eg. because it was setup by MEstimateEnergy)
993 it will be written to the output file.
994
995
996
997 *** Version 1.0 (2007/02/16)
998
999 - database: Website to plot values from the database has been added.
1000
1001 - database: The rate of spark events as found by star is now kept
1002 and the rate after cleaning is now with spark events subtracted
1003
1004 - general: The changes to the interpretation of phrases lead to
1005 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1006
1007 - general: Added example files how you can create your own calendar
1008 (eg. as christmas present) with Mars. Just run
1009 root macros/tutorials/calendar.C
1010
1011 - general: Added a possibility to display grouped data in the plotdb.C
1012 macro (and similar macros). This allows to plot hourly, nightly,
1013 weekly, monthly and yearly averages.
1014 For more details see the plotall function of the macro
1015
1016 - general: fixed the error display of the camera display. It showed
1017 wrong results.
1018
1019 - general: fixed a memory leak when reading many MStatusDisplays
1020
1021 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1022 between a spherical and a parabolic mirror
1023
1024 - callisto: We have a new pulse position check which takes the properties
1025 of the extractor automatically into account. So no need to set
1026 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1027 left is done. If possible the lo-gain extraction start and hi-gain
1028 extraction end is changed accordingly. If no proper extraction range
1029 can be set (hi-gain too much to the left) an error is raised.
1030
1031 - callisto: New swapped pixels have been found and corrected
1032
1033 - callisto: Redone the signal extraction this includes:
1034 + Unified the algorithms to extract the pedestal for all pedestal
1035 extractions done
1036 + Unification of hi- and lo-gain into one array
1037 + Unification of hi- and lo-gain extraction for Spline and
1038 Digital Filter (means now exactly the same algorithm is used,
1039 not a copy-and-pasted one)
1040 + Store pedestal subtracted data in a common place
1041 + Improved extraction algorithms. If the algorithms search a
1042 maximum but don't find one they don't return the maximum anymore
1043 + Improved the extraction such that a information for signal
1044 and time which is consistent is returned
1045 + replaced the numerical spline with a (not slower) analytical
1046 solution
1047 + Lowered the saturation limit from 250 to 245 to make sure that
1048 we are far away in all pixels from problems with the clock-noise
1049 + The start of the lo-gain extraction is calculated from the hi-gain
1050 arrival time. In case of saturation an estimation is used.
1051 + the hi-gain window was extended to slice 16. This allows extraction
1052 of very late pulses in single pixels or of huge hadron showers.
1053 + Now uses the lo-gain extraction range for pedestal extraction,
1054 not the hi-gain range in the lo-gain
1055
1056 - callisto: New hi-/lo-gain calibration constants have been produced
1057 for all periods from the statistic of the whole period. They are
1058 now used automatically depending on the periods. The old constants
1059 where deviation in avarega about 2%-3%. The constants are very
1060 stable from period to period (<<1%) except for exchanged channels.
1061 In a few cases the constants used so far were off by 1%-2% (maybe
1062 temperature effects?)
1063
1064 - callisto: To gain obsolete space we do not write the
1065 MPedestalFundamental anymore. Also calibration and bad pixel
1066 treatment is not done for it anymore because it has never been used.
1067
1068 - callisto: Fixed a bug in the seuqence handling which caused the
1069 light condition to be ignored
1070
1071 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1072 basically the same as "Cleaned" but the distribution devided into
1073 the events fullfilling a spark cut or being rejected by it.
1074 This cut can be changed from star.rc (see example inside) by
1075 the "SparkCut" directive
1076
1077 - star: Star displays now the average individual pixel-rate (IPR) versus
1078 time and the average discriminator threshold (DT) of all pixels.
1079
1080 - optim: fixed a problem with the optim-macros which was due to a bug
1081 in the new phrase parsing
1082
1083 - ganymed: To get a nice FalseSource plot (instead of the all-information
1084 debug plot displayed as a standard plot) use the context menu
1085 somewhere between the two upper plots, click on "DrawNicePlot"
1086 and enjoy the result. (It is the same context menu which contains
1087 the other options)
1088 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1089
1090 - ganymed/optim/train: The cut program, trainings- and optimization
1091 macros could run with less files found than expected from the
1092 sequence-files. No the execution is stopped in this case.
1093
1094 - ganymed: now stores the dataset in the output file with all information
1095 contained (as sequence number, sequence path, data path) so that the
1096 used dataset file can be recreated complete from the output
1097
1098 - sponde: now also allows the uasge of random forest
1099
1100 - sponde: added a plot showing the cut efficiency
1101
1102 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1103 errors (eg. effecting the collection area) because the errors of the
1104 two histograms were swapped in the calculation, which makes a difference
1105 in the case the histograms contains weighted events. Aditionally the
1106 totalarea was incorrectly taken into account, which results in too small
1107 errors, which makes a difference at low statistics were the errors
1108 or the collection area dominate.
1109
1110
1111
1112 *** Version 0.10.3 (2006/10/23)
1113
1114 - database: Implemented ObservationMode flag in websites.
1115
1116 - database: For sequences there is now also the stoptime available on the
1117 websites.
1118
1119 - database: Removed ManuallyChanged flag from sequence-info websites,
1120 as it is not needed anymore with the new sequence building algorithm.
1121
1122 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1123 Class for calculation of confidence intervals (upper limits).
1124 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1125 Please read the class instruction of TRolke for more information.
1126
1127 - general: The programs now return 0xfe if the requested resource file
1128 doesn't exist.
1129
1130 - general: Errors comming from root itself are now not output to
1131 stderr anymore but to our default (colored) log-stream.
1132
1133 - general: Changed the interface to TFormula such that now everything
1134 is parsed by TFormula, which should allow to use phrases even
1135 without paranthesis correctly parsed.
1136
1137 - callisto: replaced the AdHoc number of effective integration slices
1138 in the digital filter by an average of the correct number, averaged
1139 over all possible set of weights. This also gives correct numbers
1140 for the lo-gains which were totally wrong before.
1141
1142 - callisto: drastically reduced memory consumption by not storing
1143 all intermediate calibration results in memory anymore (we might
1144 write them into a file in the future)
1145
1146 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1147 debug plot displayed as a standard plot) use the context menu
1148 somewhere between the two upper plots, click on "DrawNicePlot"
1149 and enjoy the result. (It is the same context menu which contains
1150 the "DrawAll" option)
1151 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1152
1153
1154
1155 *** Version 0.10.2 (2006/10/15)
1156
1157 - general: changed the building of the sequence files such, that
1158 the source-/project name in case of wobble-sources is not the
1159 source/project of the first data run anymore but the new generalized
1160 wobble source/project
1161
1162 - general: Added some functions to MAstro to calculate sun and
1163 moon properties
1164
1165 - general: Added two new macros (starvisday.C and starvisyear.C)
1166 which allow to plot the visibility of several stars in one day
1167 or of one star along one year
1168
1169
1170
1171 *** Version 0.10.1 (2006/10/11)
1172
1173 - general: HTML logging output was distorted... fixed.
1174
1175 - general: Changed the writing of the sequencefiles such that only
1176 as many pedestal files as giving at least 1000 pedestal events which
1177 are nearby the first calibration run are used as pedestal runs
1178
1179 - sponde: In the calculation of the collection area(s) and the
1180 distribution for MOnte Carlo and estimated energy the error
1181 calculation was wrong because root didn't take the errors
1182 properly into account... fixed.
1183
1184
1185
1186 *** Version 0.10 (2006/10/10)
1187
1188 - general: all executables now check consistency of the root version
1189 installed with the root version used for compilation. The return
1190 code in this case is 255.
1191
1192 - general: The algorithm to build seqeunces has been redesigned
1193 completly. It is now more flexible in terms of a resource file
1194 resources/sequences.rc which can be used to partly overwrite
1195 the default algorithm and defined the important part of the
1196 algorithm. It also takes correctly into account several ways
1197 of taking wobble-data. Currently the new algorithm doesn't take
1198 the number of pedestal events anymore into account (so a sequence
1199 could have much less than 1000 pedestal events and data runs are
1200 no-more used instead)
1201
1202 - general: a lot of small changes to make the code compatible with
1203 root 5.12/00 and gcc 4.1
1204
1205 - general: Fixed some warnings thrown if more warnings are switched
1206 on in the compiler
1207
1208 - general: Added a function to MMath which returns the Median of
1209 the distribution abs(y[i]-median) but at 68:32 division instead
1210 of 50:50, which is somehow the median counterpart of the rms.
1211
1212 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1213 even if they are compressed with gzip (recommended compression
1214 is with "-1")
1215
1216 - showplot:
1217 + batch mode creation of image files now works with root 5.12/00
1218 + added support for writing bmp (though it never produces
1219 bmp which can be read by programs like xv or gimp)
1220 + added support for xml
1221 + added new option to start the display with a different size, by
1222 --display-width=nnn or --display-height=nnn
1223 + added options to define the canvas size when the display is started
1224 --canvas-width=nnn or --canvas-height=nnn
1225 the option can also be used for batch-mode conversion
1226 + added an option which automatically fits the display size to the
1227 desktop-size: --auto-size
1228
1229 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1230
1231 - merpp: allow the reports to have 1000ms due to a bug in the camera
1232 program.
1233
1234 - callisto: New swapped pixels have been found and corrected. For
1235 details see MRawRunHeader::FixAssignment()
1236
1237 - callisto: Callisto now raises an error if one of the input files could
1238 not be opened.
1239
1240 - callisto: In some rare cases it could happen that in the signal
1241 extraction of the digital filter the extractor returned nonsense
1242 results due a wrong initializion of a variable (this happens in
1243 cases in which the extracted signal is exactly zero or the
1244 digital filter couldn't slide because of a too small extraction
1245 window, which could happen in the lo-gain extraction)
1246
1247 - callisto: The lo-gains have been marked as valid in some cases
1248 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1249 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1250 smaller than the number of slices (fLoGainWindowSize) needed
1251 by the lo-gain extractor
1252
1253 - callisto: Updated absolute calibration constants (muon calibration)
1254
1255 - callisto: fixed a bug which caused the hi-gain saturation not
1256 to be handled properly in the spline (the position of the
1257 saturation was calculated incorrectly)
1258
1259 - callisto: fixed a bug which gave weird results if hi- _and_
1260 lo-gain could not be extracted properly. In some cases hi-
1261 and lo-gain have not been extracted at all and the random result
1262 got calibrated. In other cases the hi-gain was saturating and the
1263 lo-gain has not been extracted. For this a completly arbitraty
1264 scale factor was applied to the result from extracting the
1265 charge of the saturating hi-gain.
1266
1267 - callisto: improves handling of extracted signal if lo- and/or
1268 hi-gain could not be extracted properly. If no appropriate
1269 calibration of either the signal or the arrival time is possible
1270 the pixel is now markes as unsuitable instead of estimated.
1271
1272 - callisto: Fixed a problem in the spline extraction which gave
1273 weird results if the signal was extracted from the first (and
1274 highest) slice (as a workaround extraction from the first
1275 slice has been forbidden)
1276
1277 - callisto: Fixed a bug regarding the use of the QE which doesn't
1278 effect the result because the default is used anyhow.
1279 (The bug was there since 14/07/2005)
1280
1281 - callisto: Changed the default for fgLoGainStartShift to -2.4
1282
1283 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1284 factors to be always 10 for all pixels as soon as the first
1285 calibration update has happend.
1286
1287 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1288 was off by more than one slice (which gives wrong values for
1289 pixels which have saturated the hi-gain) This was a problem
1290 mainly for timing studies, not so much for the automatic standard
1291 analysis. Also the values for the Spline have been changed slightly:
1292 + Digital Filter from 1.70 to 0.95
1293 + Spline from 1.39 to 1.30
1294 The numbers were sorted out by an extensive test in the
1295 test-database.
1296
1297 - callisto: Removed the tab showing the average calibrated arrival
1298 time. It never gave useful information.
1299
1300 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1301 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1302 and both were extracted because the hi-gain was above the
1303 LoGainSwitch.
1304
1305 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1306 lo-gain pulse position (after application of LoGainOffset, which
1307 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1308 have saturated and both were extracted because the hi-gain was above
1309 the LoGainSwitch.
1310
1311 - callisto: After extensive tests a new threshold level for determination
1312 of the pulse position has been found at 50phe. This is due to the
1313 fact that for lower pulses the arrival time changes its average
1314 behaviour dramatically. It tends to the average of the extraction
1315 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1316
1317 - callisto: Added two more plots to the calibration part. The average
1318 extracted signal and the average extracted arrival time as
1319 extracted by the signal extractor (This can help debugging problems
1320 because it doesn't involve a fit)
1321
1322 - star: changed the fit for the effective on time such that initial
1323 values are calculated automatically now instead of using build
1324 in values. This makes the fit more indepedant of the underlaying
1325 rates. With a test of ~350 sequences in the test database it could
1326 be shown that the new fit gives the same result +/-1sek.
1327 The highest deviation was +5s the lowest -10s. You can now control
1328 the bahaviour with two resource values:
1329 MHEffectiveOnTime.FistBin: 3
1330 MHEffectiveOnTime.NumEvents: 12000
1331 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1332 from the resulting gamma candidates
1333
1334 - star: The Center histogram in MHHillas is now by default displayed
1335 with the colz draw-option
1336
1337 - ganymed: now produces valid error codes if failed
1338
1339 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1340 with the option "hadronness" instead of "area" or "both" if
1341 you want to use both cuts. The hadronness cut includes a fixed
1342 cut in hadronness (index 8) and a fixed cut in size (index 9).
1343
1344 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1345 the M3Long of the anti source to be not properly evaluated
1346 (actually is was evaluated as a unique random number) in case
1347 of optimization with anti-theta cut switched on. This might have
1348 lead to improper, but not necessarily wrong, optimization results.
1349
1350 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1351 how to use random forest
1352
1353 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1354 ganymed_onoff.rc. Seems to be unintentional that they were different.
1355
1356 - sponde: Since the introduction of the possibility to define a
1357 normalization energy instead of using the integral the default
1358 was not using the integral anymore but a normalization energy of
1359 1GeV. It is now the integral again.
1360
1361 - sponde: Fixed a problem in the weighting which did not allow
1362 a MC slope of -1.
1363
1364
1365
1366 *** Version 0.9.6 (2006/05/24)
1367
1368 - general: changed the binning of the azimuthal profile of the camera
1369 such that it is aligned with the 60deg boundaries.
1370
1371 - merpp: better handling of problems with the TH, TD part of the
1372 CC-REPORT for files older than 200507190 and 200412210
1373 respectively
1374
1375 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1376
1377 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1378
1379 - callisto: if an arrival time is extracted outside the fadc range is
1380 was set to the boundary before. Now a random number is assigned
1381 instead to avoid unfortunate coincidences of arrival times just
1382 by this arbitrary value.
1383
1384 - callisto: added a new option to callisto.rc which allows
1385 to set the maximum arrival time difference allowed for the
1386 badpixel algorithm to determin whether a pixels belongs to a shower:
1387 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1388
1389 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1390 to 0.9 as suggested by Stefan due to a recent study on the fraction
1391 of pixels surviving the image cleaning
1392
1393 - callisto: switched off error in case of "pulse is too much to the left"
1394
1395 - callisto: The extraction window is not adapted anymore. This means that
1396 the pulse is extracted from the full range. The draw-back is that the
1397 background (pedestal) will become slightly higher. Switching on/off
1398 the PulsePosCheck in the callisto.rc only effects filling the
1399 histograms.
1400 WARNING: If the pulse is too much to the left data is calibrated!
1401 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1402 in the database to make sure that your data is valid!
1403
1404 - star: Show also the number of stars correlated correctly by the
1405 starguider
1406
1407 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1408 than one off-source region in wobble-mode. To use it add the following to
1409 your ganymed_wobble.rc:
1410 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1411 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1412 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1413 + Cut1.ThetaCut: None
1414 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1415
1416 - ganymed: in the case the latest report is older than a default (currently
1417 one minute) and the current report will be skip the starguider
1418 correction and calibration will be reset. The maximum age can be
1419 setup from ganymed.rc by (minutes):
1420 MPointingDevCalc.MaxAge: 1.5
1421
1422 - ganymed: A first implementation showing all size-bins for the theta-sq
1423 resp. alpha-plots in a single tab automatically
1424
1425
1426
1427 *** Version 0.9.5.1 (2006/05/05)
1428
1429 - general: Added a new option "zdiff" to the Makefile which runs
1430 "cvs diff" as "make diff" would do, but with compression
1431
1432 - general: accelerated MTFillMatrix (used for eample in all training
1433 and optimization macros) by skipping some obsolete calles in the
1434 eventloop the first and second loop could be accelerated by ~20%
1435
1436 - general: Added a missing feature in the MFilterList class which
1437 prevented MFEnergySlope from working correctly in trainenergy.C
1438
1439 - general: Accelerated the random forest training and usage a bit
1440
1441 - merpp: Adapted to new raw data file format version 6
1442
1443 - merpp: fixed a problem with reading the starguider reports
1444 after 6.3.2006
1445
1446 - callisto: At some times six pixels had to be exchanged manually in the
1447 data. If the pixels to be swaped are both not found, an error was raised
1448 and calibration was stopped. Now it is assumed they are intentially not
1449 mapped and the Error has been changed to a Warning.
1450
1451 - star: Added new image cleaning based on the arrival time of the shower.
1452 The new cleaning can be accessed using the parameter "Time" instead of
1453 the the old one (like "Absolute) in the star.rc-file.
1454 Recommended parameters:
1455 + MImgCleanStd.CleanLevel1: 8.2
1456 + MImgCleanStd.CleanLevel2: 5
1457 + MImgCleanStd.CleanRings: 2
1458 + MImgCleanStd.KeepSinglePixels: No
1459
1460 - star: Simplified the calculation of the effective on time. By letting
1461 the fit start in the third bin the result should become more stable.
1462 The fit quality is now ignored for the theta-plot which is not used
1463 in the analysis later. Still better pre-cut which, for example,
1464 remove events triggered by car-light (rate changing on a short
1465 time-scale) are missing.
1466
1467 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1468 for optimization (kWeakSource) which is suggested by the Berlin
1469 people for weak sources.
1470
1471 - macros: plotdb.C:
1472 + if no dataset and no time-interval is given only sequences with
1473 an effective on-time above five minutes are plotted anymore
1474 + added a new tab "RelTime" displaying the relative on-time
1475 (effective on-time divided by the observation time)
1476
1477 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1478 the optimization became a lot faster
1479
1480 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1481 To display them just delete the pads displayed on top.
1482
1483 - ganymed: fixed a bug which could cause strange behaviour in wobble
1484 mode if no starguider information was available due to an incorrect
1485 initialization of the starguider calibration
1486
1487 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1488 be changed from within the plot. It can also be setup from the
1489 resource file using:
1490 + MHDisp.fScaleMin: 0.325
1491 + MHDisp.fScaleMax: 0.475
1492
1493 - ganymed, showplot: Fixed a problem with the fit to the off-data
1494 (HistOff) which could cause a time lag or an inifinite loop.
1495 The bug did not effect the results at all.
1496
1497 - sponde: Added a new tab showing the effective collection area after
1498 trigger (including the software trigger)
1499
1500 - sponde: MMcSpectrumWeight has a new option which allows to define
1501 the scaling factor not by the integral of the events but at
1502 a defined energy:
1503 e.g. MMcSpectrumWeight.NormEnergy: 200
1504
1505 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1506 eventloops the loop could be accelerated by ~20%
1507
1508
1509
1510 *** Version 0.9.5 (2006/03/13)
1511
1512 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1513 and added the standard Disp-parametrization
1514
1515 - macros: added a new macro datacenter/macros/plotstat.C allowing
1516 to plot statistics about the data processing
1517
1518 - macros: added a new macro to plot the muon correction coefficients
1519 versus period (macros/plot/mucal.C)
1520
1521 - showplot: path inflation for ganymed files was broken
1522
1523 - callisto: Fixed an important bug. When the number of saturating pixels
1524 were calculated the bad pixel information already available from the
1525 calibration was ignored. This yields wrong values in case pixels
1526 are broken and saturate all the time or randomly.
1527
1528 - callisto: Updated Muon calibration constants. Spline data now also uses
1529 different values for different periods
1530
1531 - star: The time-evolution shown in the effective on-time plot now displays
1532 the axis range (if there are no holes it should be similar to the
1533 effective on-time)
1534
1535 - star: Added two new image parameters:
1536 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1537 the three pixels next to the center of gravity and the size
1538 + MNewImagePar.fConcCore: The ratio of the signals of all
1539 pixels inside or touching the ellipse and the size
1540
1541 - ganymed: now stops in requested source isn't found in catalog file
1542
1543 - ganymed: Many improvements to the phi-plot in wobble mode:
1544 + with a template the ideal background is displayed
1545 + a possible camera inhomogeneity is taken into account
1546 + the anti theta cut is better supported
1547 + the phi cut is automatically calculated from the theta cut
1548 See the examples in ganymed_wobble.rc for more details.
1549
1550 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1551 times the bin-width instead of the absolute energy
1552
1553 - ganymed: New cuts for on/off and wobble mode
1554
1555 - ganymed: The smearing of the False Source plot has been increased
1556 to 0.06
1557
1558 - ganymed: The starguider calibration can now be changed from the
1559 resource file.
1560 See the examples in ganymed*.rc for more details.
1561
1562 - ganymed: added a new option for on-/off-observations
1563 MJCut.RandomSourcePosition
1564 If switched on the distribution of observation time of the source
1565 position in the camera is calculated from the on-data and randomly
1566 applied with this distrbution to the off-data.
1567
1568 - ganymed: by skipping some obsolete calles in the eventloop the
1569 first and second loop could be accelerated by ~20%
1570
1571 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1572 position in the off-data randomly according to its distribution in the
1573 on-data.
1574
1575
1576
1577 *** Version 0.9.4.3 (2006/02/13)
1578
1579 - general: Fixed a bug in most of the programs which prevented the
1580 compile date in the startup message to be displayed
1581
1582 - general: Simplified program calls. The following abbreviations
1583 are now possible:
1584 showlog callisto 55599
1585 showplot signal 55599
1586 star 55599
1587 callisto 55999
1588 ganymed 2
1589 In this cases the corrsponding root-, log-, sequence- or dataset-
1590 filename is automatically compiled using the default datacenter
1591 paths ("/magic/*")
1592
1593 - general: Fixed a long outstanding bug which made axis tick marks
1594 disappear if MDataFormula was used (eg. abs(x))
1595
1596 - general: Updated MMath with new functions to calculate the results of
1597 a exponential, logarithmic and powerlaw fits analytically.
1598
1599 - general: Updated some macros with comments:
1600 + macros/optim/optimdisp.C
1601 + macros/optim/optimenergy.C
1602 + macros/optim/optimwobble.C:
1603
1604 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1605 files) now allows adding a pre-cut like in the optimization. E.g. this
1606 is useful to perform g/h-separation cuts before training the random
1607 forest.
1608
1609 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1610 correctly assigned in the raw data assignement table. A fix to correct
1611 the assignment tabel have been implemented.
1612
1613 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1614 by 90, 180 and 270 deg.
1615
1616 - general: the macro plotdb.C now allows to highlight sequences belonging
1617 to a datset. For more details see the descritions in the macro.
1618
1619 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1620 of the display, it gave wrong results espacially for big sizes.
1621 Now the embedded canvas should always have a ratio width/height=3/2.
1622 The "Size" options have been updated with values fitting the 3/2
1623 size ratio.
1624
1625 - RanForest:
1626 + Updated the random forest classes to support also the
1627 regression method implemented by Thomas H.
1628 + added new tutorial macro how to train the random forest
1629 for energy estimation (macros/optim/rfenergyest.C)
1630 + new classes to train the random forest (still in development)
1631 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1632 + new tutorial macros for random forest training in macros/train
1633 trainenergy.C, traindisp.C, trainseparation.C
1634
1635 - mars: now allows to setup a cut in the resource file mars.rc to choose
1636 the events to be displayed, eg:
1637 Cut.Condition: {0} && {1}
1638 Cut.0: MHillas.fSize>100
1639 Cut.1: MHillas.fSize<900
1640
1641 - merpp: Made aware of the new .rep format 200510250. This includes
1642 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1643 the discriminator thresholds (MCameraTD) and the disciminator
1644 delays (MCameraTD). All of them come with the CC report and are therefor
1645 written to the CC tree.
1646
1647 - callisto: fixed a bug in the calculation of the arrival times in
1648 the Digital Filter. They were all shifted by the same amount
1649 fHiGainFirst. This caused an offset in the order of the position of
1650 the left border of the extraction window in the times calculated
1651 from high-gain and from low-gain. The bug effected only the absolute
1652 arrival times. The bug was there since 30.1.2005.
1653
1654 - callisto: Changed the ExtractionWindow for the pulse position check
1655 such that the camera inhomogeneity becomes as less as possible and
1656 comparable to the pulso position check switched off. More details
1657 on the study will be given at our result web-page.
1658
1659 - ganymed: ganymed.rc, ganymed_onoff.rc:
1660 changed to new cuts trained with 1ES1218 and Crab-data
1661 for maximum sigma*log10(excess)
1662
1663 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1664 a new option was implemented to estimate Disp (CalcDisp)
1665
1666 - ganymed: Implemented two new options which allow
1667 to overwrite the default path to search for the sequence files
1668 --ins=/magic/sequences
1669 and where to search for the image data
1670 --ind=/magic/data/star
1671
1672 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1673 dx/dy from the resource file by
1674 MSrcPosCorrect.Dx
1675 MSrcPosCorrect.Dy
1676
1677 - ganymed: fixed reading the source catalog. Only as many chars
1678 as the requested source name had were compared (If a source
1679 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1680 were requested it could happen that the coordinates of
1681 "1ES1218" were read) The source coordinates are now printed
1682 in addition to its name to the logging output.
1683
1684 - ganymed: changed the background fit in the case of a ThetaSq function
1685 from a polynomial to a exponential, this should give a big improvement
1686 for on-only analysis'
1687
1688 - ganymed/sponde: Calculation of the error of single size-/energy-
1689 bins now uses Li/Ma (5) instead of LiMa (17)
1690
1691 - sponde: Added a plot E^2*dN/dE
1692
1693 - sponde: The energy estimator plot should now show values like
1694 they are commonly used.
1695
1696 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1697 (a powerlaw with cutoff didn't work before)
1698
1699
1700
1701 *** Version 0.9.4.2 (2005/10/01)
1702
1703 - general: added new tutorial macro macros/tutorials/threshold.C:
1704 how to calculate the threshold
1705
1706 - general: added a new game. Start it from the interpreter with
1707 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1708 and MagicReversi)
1709
1710 - general: neighbor pixels in MGeoms are now sorted clockwise
1711
1712 - merpp: made aware of new format 20050829-0
1713
1714 - callisto: New scale factors from muon analysis, stored in new
1715 resource file resources/calibration.rc
1716
1717 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1718 the eventloop if something went wrong. This is necessary for the
1719 automatic processing
1720
1721 - callisto: Implemented a new treatment for the time information
1722 developed by S.Ruegamer, this should give much better response than
1723 the old very primitive algorithm. This is especially important
1724 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1725 treatment was buggy! As neighbor pixels to interpolate the
1726 arrival times always the pixels 0 to 5 were taken)
1727
1728 - callisto: In addition to the new treatment of arrival times the
1729 decision of the treatment whether a pixel contains shower
1730 information or not is used to improve the signal interpolation
1731 further. Previously interpolated pixels showed a non-zero signal
1732 do the peak searching signal extractors. Having a signal pixel
1733 beside raised the signal above the cleaning level. Thus the
1734 pixel survived cleaning to often but with a too low mean signal.
1735 By replacing empty pixels with a gaus (mean and rms from the
1736 corresponding Area entries in MPedPhotCam) this effect can
1737 be supressed.
1738
1739 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1740 got lost when the events were stored by the calibration... fixed.
1741 (This was no problem for normal image cleaning because the pixel
1742 content was artificially set to 0 not surviving standard cleaning
1743 algorithm)
1744
1745 - callisto: Fixed a bug which caused the random and peak-search pedestal
1746 extracted with an extractor to be exchanged for the first (roughly)
1747 500 events (*Extractor and *ExtractorRndm).
1748 (They were simply exchanged in callisto.cc) This bug might have been
1749 introduced in Mars 0.9.4 when the order of calculation of the two
1750 types of pedestal in callisto got exchanged. The bug only effects
1751 the first seconds of data of each sequence.
1752
1753 - star: Taking the arrival time of Muons into account the calculation
1754 of the parameters could be made independant of the noise
1755 (pedestal rms). The dependance was due to the bias of the peak search
1756 extractor. Now only a ZA dependamcy is left which is not yet fully
1757 understood.
1758
1759 - ganymed: The sequences were still not sorted correctly in any case,
1760 because they were sorted by the full qualified path name. Now they
1761 are sorted by their sequence number.
1762
1763 - ganymed: new values for the spark-event-cut
1764
1765 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1766
1767
1768
1769 *** Version 0.9.4.1 (2005/08/18)
1770
1771 - callisto: fixed some problems with the calibration in case of
1772 inteleaved events. Therefor the final and some intermediate
1773 fits are skipped which would take place on partly filled #
1774 histograms and gave wrong results or failed completely.
1775
1776 - callisto: If the intermediate finalization of the histograms
1777 calculating the mean charge of the calibration signal fails
1778 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1779
1780 - ganymed: Fixed some bugs which caused problems in On-only mode.
1781 Still the false source plot doesn't give reasonable results.
1782
1783
1784
1785 *** Version 0.9.4 (2005/08/05)
1786
1787 - general: Fixed the ZA binning. It did not correctly fit the
1788 MC binning
1789
1790 - general: Added a class to correct for the missfocussing in
1791 April (MSrcPosCorrect)
1792
1793 - general: Random Forest energy estimator should now work properly
1794
1795 - general: MHCamera now displays the profiles in deg instead of mm
1796
1797 - general: MH::SetPalette offers a lot of new palettes
1798
1799 - general: MHillas - the case of CorrXY==0 is now handled properly
1800
1801 - general: implemented the possibility to change the line and
1802 marker style of a sky-grid drawn by MAstroCatalog
1803
1804 - general: Runs in sequences and datasets are now automatically
1805 ordered (it is assumed that the order of their filenames correctly
1806 represents the order of observations) to ensure correct reading
1807 of the subsystem data
1808
1809 - general: Runs cannot be added to a sequence twice anymore. Also
1810 Sequences cannot be added twice anymore to a dataset.
1811
1812 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1813 It gave wrong results by 1./2pi
1814
1815 - showplot: got a new option to start a root interpreter, too
1816
1817 - mars: now displays a rough estimate of Disp and the third moment
1818
1819 - mars: now displays the event time MTime if available
1820
1821 - mars: show muon parameters graphically
1822
1823 - mars: now the file to open can be given as commandline
1824 argument
1825
1826 - merpp: Added support for new arehucas version >= 200507190
1827 implementing values for three temperature sensors in the
1828 counting house (MCameraAUX) and the name of the HV settings file
1829 (MCameraHV).
1830
1831 - merrp: Also fixed some problems with wrong versions numbers stated
1832 by arehucas and implemented some fixed for old versions (<200407070)
1833
1834 - callisto: MCalibrationHiLoCam can now be printed from its context
1835 menu, eg in the TBrowser
1836
1837 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1838 - 1.39 (MExtractTimeAndChargeSpline)
1839 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1840 This is important mainly for timing studies.
1841
1842 - callisto: Changed limits in MHCalibrationChargeCalc from
1843 - -100.125 to -98 (fgChargeHiGainFirst)
1844 - 1899.875 to 1902. (fgChargeHiGainLast)
1845 - -100.25 to -99 (fgChargeLoGainFirst)
1846 - 899.75 to 901. (fgChargeLoGainLast)
1847 Introduced new limits:
1848 - fgNumLoGainBlackoutLimit: 0.05
1849 - fgLoGainBlackoutLimit: 3.5
1850 - fgLoGainPickupLimit: 3.5
1851
1852 - callisto: The handling of automatic weights for the digital filter
1853 has been improved. There are now new calibration weights special
1854 for Monte Carlo calibrations.
1855
1856 - callisto: Updated Muon scale with latest results (1% difference
1857 for most data, 5% for Mar/Apr'05)
1858
1859 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1860 was saturated and the blackout-events in the low-gain exceed the
1861 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1862 This excludes those pixels which have a saturating high-gain
1863 channel, but the low-gain switch does not switch often enough
1864 to make the distribution reliable.
1865
1866 - callisto: fix a bug counting the number of saturated events. Up to now,
1867 the number of saturated slices was counted (which is one for a not too
1868 high number), but for some (pathological) pixels, many more slices
1869 saturated and produced wrong limits.
1870
1871 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1872 + MCalibrationRelTimeCam.CheckFitResults: Yes
1873 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1874 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1875 + MCalibrationRelTimeCam.CheckOscillations: Yes
1876
1877 - callisto: introduce max. number of events for intercalibration,
1878 the rest gets skipped. Default: 4096
1879 The calibration causes too many un-reliable pixels if more
1880 than about 5000 events are treated (@500 Hz) because of the
1881 mode hopping of the VCSels. However, in the past, some
1882 calibration runs have been taken (erroneously) with more
1883 than 5000 events, especially the intensity scans where
1884 a good precision is needed.
1885
1886 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1887 photo-electrons for the spline extractor by 1-2% (correctly).
1888
1889 - callisto: The intercalibration is now done using a full f-factor
1890 method instead of a simple update. This makes things slower but
1891 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1892 changes.
1893
1894 - callisto: MPedestalY3 now uses the same extraction range as the data
1895 as calculated by MPedestalY2
1896
1897 - callisto: A check of the fraction of allowed unsuitable (10%) and
1898 unreliable (30%) pixels has been addded when the conversion is
1899 calculated from interleaved events
1900
1901 - star: fixed a bug which caused MEffectiveOnTime containers not to
1902 be written. In the worst case they were skipped almost all, in the
1903 best case they were all ok. It depends on how often the new value
1904 was assigned just with an event which was skipped later by another
1905 task
1906
1907 - star: new histograms MHPointing and MHRate
1908
1909 - star: New tab (Currents) displaying the time evolution of the mean
1910 DC currents
1911
1912 - star: New tab (MeanRms) displaying the time volution of the mean
1913 Pedestal Rms
1914
1915 - star: Output now contains MReportStarguider
1916
1917 - star: Improved muon analysis. Due to the absense of a constant
1918 for the gaus fit for arc width and the fact that the arcwidth
1919 plot was a histogram instead of a profile the resulting psf
1920 became pedestal rms dependant
1921
1922 - ganymed: added new plot (MHPhi) for wobble mode as described in
1923 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1924
1925 - ganymed: corrects now (correctly?) for the misspointing in
1926 May/April 05
1927
1928 - ganymed: Two new default templates for ganymed.rc are avilable:
1929 ganymed_onoff.rc and ganymed_wobble.rc
1930
1931 - ganymed: The first version of MFMagicCuts has been released
1932
1933 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1934
1935 - ganymed, sponde: There are two new options to determin the number
1936 of bins for the signal region (NumBinsSignal) and the number of
1937 total bins (NumBinsTotal) in the MHThetaSq histogram
1938
1939 - ganymed: optimized palettes for MHDisp
1940
1941 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1942 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1943 sqrt(2) to large
1944
1945 - ganymed: The false source plot (MHDisp) is now based on Disp
1946 and a background model determined in the first loop is
1947 subtracted
1948
1949 - ganymed: MFMagicCuts are now available in the cvs. The correct
1950 solution for the disp ambiguity problem is now calculated using
1951 the third moment. The third moment cut therefor is skipped.
1952
1953 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1954 already determined by the third moment along the major axis and
1955 so its actual sign is aligned along the major axis of the shower.
1956
1957 - ganymed: If starguider data is available it is taken into account
1958 when calculating the source position. This is especially important
1959 for wobble data at high zenith angles and culmination data.
1960
1961 - ganymed: If available the starguider data is taken into account as
1962 good as it is possible without a starguider calibration. To switch
1963 it off add
1964 MPointingDevCalc.MaxAbsDev: -1
1965 to your ganymed.rc
1966
1967 - sponde: the zenith angle distribution is now weighted instead of
1968 choosen by default. This gurantees higher statistics in the highest
1969 and lowest energy bins. To switch this behaviour off use...
1970
1971 - sponde: now automatically displays the energy threshold
1972
1973
1974
1975 *** Version 0.9.3 (2005/06/03)
1976
1977 - general: MMcEvt now derived from MMcEvtBasic which should
1978 have no influence on compatibility with older camera files
1979
1980 - general: Implemented a new option to MReadReports which allows
1981 to force reading of the first event of some trees (eg. Drive-tree)
1982 before any other tree.
1983
1984 - general: Made a fix to MPointingPosCalc which assumes that the
1985 run-type is real-data if Process is called before ReInit, such
1986 that also the very first Drive-events in a run are treated
1987 correctly.
1988
1989 - shoplot now displays the filename in the title bar of the window
1990
1991 - merpp: new options: --auto-time-start --auto-time-stop which
1992 allow to cut updating with slow-control at the start- or
1993 (previousle --auto-time only allowed: and) stop-time of
1994 the run stored in the runheader.
1995
1996 - callisto: changed default of fgFallTimeHiGain in
1997 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1998 already set as default in callisto_Dec04Jan05.rc
1999
2000 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2001 now changes the filename for new weights automatically for
2002 cosmics, MC and for different calibration colors.
2003
2004 - callisto: a problem with the order of some code cause the
2005 name of the weights file in MPedestalY2 to be ignored.
2006 Wrongly the calibration_UV weights were used instead
2007 of the cosmics weights set in callisto.rc.
2008
2009 - callisto: should allow ct1 pulser data when the color is
2010 explicitly set also for pretty new runs
2011
2012 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2013 to introduce an additional scale factor (should be around 1)
2014 to adapt for slight deviations in different extractors from
2015 the MC calibration. For MC calibrations the scale factor
2016 is fixed to 1
2017
2018 - callisto: MFCosmics should handle very high signals a bit
2019 more accurate now
2020
2021 - callisto: when calculating the mean pedestal rms for different
2022 pixel sizes or sectors also kUnsuitableEvt is now taken into
2023 account - not only kUnsuitableRun
2024
2025 - callisto: '-raw' option is now the default
2026
2027 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2028 This has the advantage that mean values in the calibration (eg
2029 arrival times) are calculated more accuratly.
2030
2031 - callisto: In the resource file callisto_Dec04Jan05.rc
2032 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2033
2034 - callisto: new Hi-/Lo-Gain intercalibration constants
2035 hilocalib_sp1.root and hilocalib_sp1_mc.root
2036
2037 - callisto: changed default for MJPedestalY2.MaxEvents
2038 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2039
2040 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2041 has changed from 9.0 to 6.0. This is necessary to exclude two very
2042 ringing pixels in September which - when kept - destroy the image
2043 cleaning around them (Markus G.)
2044
2045 - callisto: (!) The Muon analysis of all data taken so far has
2046 suggested that different extractors give slightly different
2047 absolute results after calibration, due to there different
2048 handling of the calibration- and cosmics pulse shape. Although
2049 the over all calibration seems to be a bit to pesimistic (or
2050 the MC seems to be a little bit - 3-5% - too much attenuated).
2051 There for correction factors have been introduced which correct
2052 the calibration constants by
2053 0.956937799 for Digital Filter (callisto.rc)
2054 and
2055 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2056 calibration. The main advantage is, that both data types can
2057 be easily analysed together and compared to the same MC sample.
2058 The factors are choosen such, that the reference is now a
2059 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2060
2061 - star: fixed a bug which caused the first bin of the histograms
2062 vs time to disapear in PostProcess. This gave wrong results
2063 on the screen. The output and all following programs not
2064 directly accessing the histograms haven't been affected
2065
2066 - star, ganymed: Made sure that always the first Drive-tree event
2067 is read and Processed before the first data event was read.
2068
2069 - ganymed: implemented the possibility to replace the standard
2070 false source plot with a different one. For example: If
2071 you want to use a Disp based FS plot use the resource:
2072 NameHistFS: MHDisp
2073 For details about the requirements of these plots look
2074 at the corresponding classes
2075
2076 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2077 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2078 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2079 case MAlphaFitter is setup correctly. For On-Only optimization
2080 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2081 RunOn() instead of Run(). For energy estimation MJOptimize
2082 has been replaced by MJOptimizeEnergy
2083
2084 - sponde: The input MC spectrum can now be weighted to fake a
2085 different spectrum. This is done via MMcSpectrumWeight. For
2086 more details see the class description and sponde.rc
2087
2088 - sponde: The paremeter comparsion plots are not scaled by
2089 their entries anymore. Instead the MC plot is scaled by using
2090 the result spectrum of the analysis. If the input MC spectrum
2091 and the result spectrum has different slopes the absolut
2092 normalization is normally wrong.
2093
2094
2095
2096 *** Version 0.9.2 (2005/05/20)
2097
2098 - general: Changed the default paths for calibrated data and image
2099 files. (The implemented access to these files doesn't yet exist)
2100
2101 - general: support for MRunIter has been removed from the job classes
2102 (use the setter functions of MSeqeunce instead)
2103
2104 - general: ProcessFile has been renamed to Process in all job classes,
2105 because ProcessFile is missleading
2106
2107 - general: The storage of the palette in MHCamera is now possible
2108
2109 - general: new bits describing unsuitable and unreliable pixels have
2110 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2111 kDeadPedestalRms, kFluctuatingArrivalTimes
2112
2113 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2114 versions newer than V200404070
2115
2116 - general: support for cc file versions newer than V200504130. Added
2117 support for active loads (MCameraActiveLoad) and central pixel
2118 (MCameraCentralPixel)
2119
2120 - general: added new histograms for image parameters versus size
2121 (MHVsSize)
2122
2123 - general: The eventloop now automatically calls PrintStatistics
2124
2125 - Status Display: Improved support for printing:
2126 + A default can now be set in .rootrc (for more details see
2127 MStatusDisplay::PrintPS)
2128 + A print dialog is opened so that printer and command line
2129 can be canged
2130
2131 - showlog: improved such that it handles different verbosity levels
2132 more accurate now. This mean you can suppress output when
2133 using showlog.
2134
2135 - showplot: improved
2136 + The new graphics formats have been implemented
2137 (pdf, svg, png, jpg and xpm)
2138 + Implemented an interface for printing. Because you can change
2139 the printing command from the command line you can use all
2140 the nice postscript tool. To print a booklet for example call:
2141 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2142 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2143 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2144
2145 - callisto: fixed a bug in the recognition of the calibration bit
2146 pattern. Concerns only intensity calibration. (The strength of the
2147 intensity has been updated in some cases)
2148
2149 - callisto: add a filter against PIN Diode events when running over
2150 calibration runs since some of the recent calibration runs have
2151 been taken with Pin Diode.
2152
2153 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2154 39943, 44833 in the calibration (MCalibColorSet)
2155
2156 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2157 been set to 1e-18 in callisto_Dec04_Jan05.rc
2158
2159 - callisto: in callisto_Dec04Jan05.rc: set value for
2160 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2161 statistics for the calculation of the mean pulse time
2162 of the cosmisc
2163
2164 - callisto: the charge limit in the calibration has been raised
2165 from 2.5 to 4.5
2166
2167 - callisto: new setup read from callisto.rc
2168 + MCalibCalcFromPast.fNumEventsDump
2169 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2170 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2171
2172 - callisto: MExtractTimeAndChargeSpline extractor:
2173 + The integration ranges were shifted by 0.2 FADC slices to the right.
2174 + unreliable handling of floating point values caused different
2175 results on different platform or with different compiler options:
2176 The new algorithm is numerically exact and more accurate because
2177 it doesn't calculate the integration position by multiple times
2178 adding the step-size (which results in numerical uncertanties
2179 exspecially if multiplied with large numbers)
2180 + A lot of fixes have been introduced which effects integrating the
2181 spline at the edges of the valid range. In this case any memory
2182 was randomly accessed. This behaviour can be tested replacing
2183 all MArrayF by TArrayF which perform a range check (but of course
2184 they are a lot slower)
2185 ! No result obtained with the Spline before can be trusted! Due to
2186 random memory access it might by completely random!
2187
2188 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2189 + extraction range in the high gain to 4.
2190 + weights file to cosmics_weights46.dat
2191
2192 - callisto:
2193 + introduce the check for fluctuating arrival times.
2194 + set charge limit to from 2.5 to 4.5
2195 + introduce asymmetric exclusion due to "deviating number of phes":
2196 Default: -9.0 +4.5
2197 + make deviating number of phes unsuitable (see David's findings).
2198
2199 - callisto: fixed the display of unsuitable pixels. The old change
2200 to a real profile in MHCamera broke it.
2201
2202 - callisto: The cosmics filter is used in MJCalibration now
2203 independant of the pulser color (formaly it was used only for
2204 CT1-pulser data). The threshold of number of max empty pixels
2205 has been raised from 2% to 5% in MJCalibration. The maximum
2206 fraction of rejected event is 50% otherwise the calibration has
2207 failed. The filter now ignores unsuitable pixels.
2208 Setup the filter from callisto.rc using "ContCosmics"
2209 (see MFCosmics::ReadEnv)
2210
2211 - callisto: changed default for fgOffsetFromLogain back
2212 from -2.8 to -1.8 in digital filter.
2213
2214 - callisto: for the common extractors
2215 + MExtractFixedWindow
2216 * MExtractTimeAndChargeSlidingWindow
2217 * MExtractTimeAndChargeSpline
2218 * MExtractTimeAndChargeDigitalFilter
2219 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2220 and fResolutionPerPheLoGain
2221
2222 - callisto: Updated the hi-/lo-gain intercalibration constants
2223 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2224 hilocalib_df6.root
2225
2226 - callisto: The default lo-gain extraction window for the
2227 MExtractTimeAndChargeSlidingWindow extractor has been increased
2228 from 6 to 8 to take the stretch of the pusle into account
2229
2230 - callisto (!!!): fixed an important bug in the setting of the
2231 incoming pedestal pointer to the signal extractor extracting
2232 pedestals. This bug caused the pedestals not to be subtracted
2233 correctly in the calibration afterwards. The effect was about 10%
2234 too high conversion factors for the digital filter and the spline
2235 and more than 40% for the sliding window.
2236 The bug existed since end of February! (Markus G.)
2237
2238 - star: added muon support to star. A new tab "MHMuonPar" is
2239 displayed. The lower right plot is an estimate of the point spread
2240 function. A reference value is displayed. To get the real PSF
2241 you must compare with MC. The setup for the muon analysis
2242 is done in star.rc. More informations can be found in
2243 MHSingleMuon and MHCalibParCalc
2244
2245 - star: The weather data is now displayed in star
2246
2247 - star: MEventRateCalc handles the calculation of the event rate more
2248 accurate now in case of the start of a new run inside a sequence
2249
2250 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2251 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2252 changed only minimally
2253
2254 - ganymed: (MJCut and MJOptimize) now displayes the number of
2255 excess events versus size. The energy estimation is done in
2256 MJSpectrum (sponde)
2257
2258 - ganymed: got support for using other variables than Alpha, eg. Theta.
2259 Therefor you need a class deriving from MHAlpha which supports
2260 this variable (one is already existing: MHTheta, which is now the
2261 default in ganymed). It is setup through ganymed.rc
2262
2263 - added a full featured spectrum program (sponde) which reads
2264 ganymed output and monte carlos and compiles a spectrum
2265
2266
2267
2268 *** Version 0.9.1 (2005/04/14)
2269
2270 - Fix bug on the arrival time reconstruction when using Digital
2271 Filter (in some marginal cases (10%) times were reconstructed shifted
2272 by 0.2 slices)
2273
2274 - all executables now return 2 where in previous versions -1 has
2275 been returned (gave problems with shell-scripts)
2276
2277 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2278 also done with a intercalibration input file
2279
2280 - a bug in the time fine adjustment of the digital filter has been fixed
2281
2282 - a lot of small fixes to calling TPad::Divide with a margin==0
2283
2284 - MStatusDisplay now shows the memory usage
2285
2286 - added a memory leak statistic after the eventloop
2287
2288 - MHadronness replaced by MParameterD
2289
2290 - MEnergyEst replaced by MParameterD
2291
2292 - wobble mode can now be switched on from the data-set
2293
2294 - switched on bad pixel detection for a pedestal level
2295 which is more than 5 times the variance
2296
2297 - Fixed default paths to be correct for the new data center
2298
2299 - Fixed handling of drive data. The pointing position in now
2300 copied to MPointingPos inside star for real and MC events
2301
2302 - made sure, that the sequences in a dataset are sorted by
2303 their number to ensure the correct synchronization
2304
2305 - added all resource files necessary to handle spline extraction
2306 of signal for the late 2004 and the early 2005 data
2307
2308 - update the reference lines for the december data
2309
2310 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2311 This is important for the Dec. and Jan. data where the calibration
2312 pulse position changes much.
2313
2314 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2315 filter. This corrects only an defective extraction of the MC at
2316 low-gain signals lower than 90 phes.
2317
2318 - fixed some slowdown in calibrating data with interleaved events from
2319 Jan and Dec. As a workaround made the pretty palette the default.
2320 The inverse Deep Blue Sea has a bug which slows down long calibration
2321 runs a lot.
2322
2323 - implemented new values from new starguider report as defined
2324 in TDAS00-07 V7.1 (eg SkyBrighness)
2325
2326 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2327 in starguider report (If you merpp the same reports with this version
2328 you'll get the correct units (arcmin) but a different result
2329 than with old versions (wrong units))
2330
2331 - Now the status display can also write PNG, JPEG and XPM (other file
2332 formats are still unsupported by root)
2333
2334 - added a lot of scripts and macros in directory datacenter used
2335 for automatic processing
2336
2337
2338
2339 *** Version 0.9 (2005/03/23)
2340
2341 - Calibration is now done autmatically into photo-electrons like
2342 decided by the Collaboration Board
2343
2344 - Reference lines in the display can be read from resource file
2345
2346 - Interlaced calibration events can be handled by callisto
2347
2348 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2349 and applied in callisto.
2350
2351 - class MJCalibTest can be called by callisto
2352
2353 - callisto can now run with three data types: rawdata, rootdata, MC
2354
2355 - added two classes mreport/MReportStarguider.cc and
2356 mreport/MReportStarguider.h for implementing starguider-data
2357
2358 - the output of merpp-update now contains starguider information:
2359 MReportStarguider and MTimeStarguider
2360
2361 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2362 values were lower than they should. This was more visible for high
2363 energy (Size) events.
2364
2365 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2366
2367 - added a new loop to callisto to support the correct extraction of
2368 the pedestal and pedestal rms through the signal extractor
2369
2370 - added class to perform fourier tranformation of a hexagonal structure
2371 (MHexagonalFT)
2372
2373 - added class to perform fourier tranformation of a hexagonal structure
2374 in a tasklist (MHexagonalFTCalc) example: hft.C
2375
2376 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2377 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2378 small pixels, example: extendcam.C
2379
2380 - added possibility to write data to memory (TTree) using MWriteRootFile
2381
2382 - added possibility to read a TTree stored only in memory by MReadTree
2383
2384 - new classes to deal with the interleaved calibration events:
2385 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2386
2387 - implemented filters to callisto to skip calibration events
2388
2389 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2390 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2391 the slices by statistics
2392 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2393 signal extractor without randomization
2394 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2395 with the signal extractor with randomization (extraction window is
2396 randomly fixed)
2397 The three kind of pedestal is not yet implemented (for speed reasons) as
2398 long as nobody really needs it:
2399 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2400 extracted with the signal extractor with randomization
2401
2402 - callisto now finds the pulse position in the data automatically
2403
2404 - implemented data reduction in calibrated data by reducing the precision
2405 of the stored floating point values (pedestal, rms and signal) to
2406 roughly 0.5%
2407
2408 - fixed showplot to make file format conversion (eg. converting a
2409 status display stored in a root file into a postscript file) in
2410 batch mode possible:
2411 showplot -b --save-as-ps[=outfile.ps] infile.root
2412
2413 - Allow class names as part of filter rules, eg
2414 (MFSupercuts) && (MHillas.fSize>100)
2415
2416 - fixed a lot of stuff to allow all programs to process MonteCarlo
2417 camera files.
2418
2419 - enhanced possibility to debug reading of resource file
2420
2421 - MDataChain should handle priorities of operator more
2422 accurate now
2423
2424 - completely revised the container in which the signal is stored
2425 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2426 * the new implementation is faster and
2427 * needs less storage space
2428
2429 - FIRST version which can process Monte Carlos through the
2430 whole chain of programs (callisto, star, etc)
2431
2432 - implemented new image parameters for the border length of
2433 the shower image (MNewImagePar2)
2434
2435 - implemented wobble-mode in ganymed
2436
2437 - new class (MJOptimize) taking care of all optimization processes
2438
2439
2440
2441 *** Version 0.8.6 (2004/10/05)
2442
2443 - New combined signal and time extractor
2444 MExtractTimeAndChargeDigitalFilter
2445
2446 - The Report for the trigger section in the CC run summary has been
2447 updated, and now the IPRs (Individual Pixel Rates) are available.
2448
2449 - new macros for database interaction: filldotrun.C, filldotrbk.C
2450
2451 - added new program which can convert colored output which was redirected
2452 into a file back into colored text (for example to display it with
2453 more): showlog
2454
2455 - added new program to display an MStatusArray of plots (stored with
2456 MStatusDisplay) from a file: showplot
2457
2458 - Added support for Sequences (MSequence). Sequences are blocks of run
2459 files containing the same calibration and belonging to the same
2460 source
2461
2462 - Added a new task (MTaskEnv) which can be used in setup files to switch
2463 between different tasks (for example to choose a signal extractor)
2464
2465 - Implemented automatic file splitting in MWriteRootFile
2466
2467 - After image cleaning an island index is assigned to all used pixels.
2468 The index corresponds to the order of the islands in size.
2469
2470 - added a cleaning which takes signal height _and_ arrival time into
2471 account: probability cleaning (for more details see MImgCleanStd)
2472
2473 - added a cleaning which takes takes the absolute number of photons
2474 times the area ratio as cleaning level
2475 (for more details see MImgCleanStd)
2476
2477 - Changed calculation of image parameters such, that it can be done
2478 for all used pixels or the pixels with a defined island index only
2479
2480 - implemented new image parameters displaying the number of islands,
2481 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2482
2483 - event display in executable changed to support also calibrated files
2484 (done with MJCalibrateSignal)
2485
2486 - added program doing the calibration and the signal extraction
2487 and signal calibration: callisto Most part of the setup is done
2488 by a resource file: callisto.rc
2489
2490 - implemented support for pixels with negative IDs (Raw file format
2491 version 4)
2492
2493 - implemented an new option in merpp (--auto-time) to get the time
2494 range for cc and/or caco data from the run header of the raw data
2495
2496 - New star-program (star and MJStar). Taking calibrated data from
2497 callisto/MJCalibrateSignal as input. The setup is done through
2498 a resource file: star.rc
2499
2500 - Added possibility to setup the eventloop in the mars-executable
2501 Camera Display by a resource file: mars.rc
2502
2503 - The the mars-executable Camera Display can now also read
2504 calibrated data files written by callisto/MJCalibrateSignal
2505
2506 - Added a new class which can calculate the source position in
2507 the camera from a pointing model known to be correct and
2508 the pointing model used for observations (MSrcPosFromModel)
2509
2510 - added a new version of the class calculating the effective on-time
2511 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2512 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2513 MHTimeDiffTheta.
2514
2515 - added the possibility to count how often a signal is above (or
2516 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2517 can replace MHTriggerLvl0)
2518
2519 - added ore convinient ways to set the axis-titles of your histograms
2520 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2521 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2522
2523
2524
2525 *** Version 0.8.5 (2004/08/06)
2526
2527 - new Signal Extractors: MExtractFixedWindowSpline
2528 and MExtractAmplitudeSpline
2529
2530 - implementes interleave in merpp to be able to merpp parts of a file
2531
2532 - implemented force-functionality to merpp
2533
2534 - star display to display star catalogs (MAstroCatalog)
2535
2536 - star display to 'mirror' stars to the camera (MAstroCamera)
2537
2538 - implemented a new cleaning option which allows cleaning scaled with
2539 the real ratio of the rms depending on the pixel size, not only the
2540 square root of the pixelsize (MImgCleanStd, MCameraData)
2541
2542 - removed obsolete MBlind* classes
2543
2544 - Signal extractor taking the AB flag into account implemented (this makes
2545 an odd number of slices for signal extraction possible
2546 (MExtractSignalABcorr)
2547
2548 - implemented a class extracting the pedestal from the raw-data (events)
2549 itself using empty lo-gain (MpedCalcFromLoGain)
2550
2551 - Added mean values to MPedPhotCam
2552
2553 - Added Makefile for Darwin (this OS is NOT officially supported!)
2554
2555
2556
2557 *** Version 0.8.4 (2004/04/19)
2558
2559 - new fast arrival time extractor using cubic splines:
2560 MExtractTimeFastSpline
2561
2562 - implementes multi-argument support in MDataChain
2563 ("pow(a, b)")
2564
2565 - implemented double reference support in MDataChain
2566 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2567
2568 - added support in MF for expressiond like
2569 "MHillas.fWidth<2*<MHillas.fLength"
2570
2571 - MDataChain is now able to support variables like [0], [1], ...
2572 which can be used in fit functions as parameters. The interface
2573 is implemented through the new virtual function
2574 MParContainer::SetVariables
2575
2576 - added new class MArrivalTimeCam/MArrivalTimePix:
2577 Storage containers to hold the ArrivalTime of the camera/pixel
2578
2579 - added new classes for the calibration of relative arrival times:
2580 MCalibrationRelTimePix and MCalibrationRelTimeCam
2581
2582 - added new classes to extract the signal of the blind pixel and the
2583 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2584
2585 - added new classes for the bad-pixels treatment (MBadPixels*)
2586 which are more powerfull than the old ones (MBlindPixel*)
2587 and will replace them.
2588
2589 - added filter against cosmics: MFCosmics
2590
2591 - added new class MArrivalTimeCalc2:
2592 Calculates the arrival time as the signal weighted mean of the time
2593 slices in the maximum window
2594
2595 - added a new macro call pointspreadfucntion.C that fits with a 2D
2596 gaussian the DC spot for an star. It gives you the RMS of
2597 the PSF and the center of the star, very useful for misspointing
2598 studies.
2599
2600 - added support for multi-telescope camera files. Added classes
2601 MStereoCalc and MStereoPar, classes to calculate and store shower
2602 parameters calculated from the data of two telescopes, for the MC
2603 studies regarding the MAGIC clone.
2604
2605 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2606 MC data calibrated in photons instead of ADC counts.
2607
2608 - added three macros to show the calibration and analysis chain of
2609 MC data. The macro starmc.C does both calibration and analysis, producing
2610 an output containing Hillas parameters for each event. The macro
2611 mccalibrate.C does just the calibration and writes out a file containing
2612 pixel information in photons instead of FADC data. The macro starmc2.C
2613 reads in such a file and produces an output with Hillas parameters.
2614
2615 - added MPedPhotCalc to compute pedestals in units of photons, see
2616 macro pedphotcalc.C
2617
2618 - added all class to perform the calibration, see macro calibration.C
2619
2620 - added class MFFT to perform Fast Fourier Transforms
2621
2622 - added class MSimulatedAnnealing to perform simulated annealing
2623 minimizations
2624
2625 - added new macro bootcampstandardanalysis.C which holds the skeleton
2626 of the analysis chain discussed in the december bootcamp.
2627
2628 - added support for DAQ raw data file format V2
2629
2630 - implemented an arbitrary time stamp for the events from raw-data
2631 files with file version<3. It is calculated from the run number,
2632 the date of start and the FADC clock tick from the first module
2633
2634 - implemented the correct decoding of the event time-stamp
2635 coming from the DAQ for raw-data files with file-version>2
2636
2637 - added a new classes storing the pedestals in units of photons:
2638 MPedPhotPix, MPedPhotCam
2639
2640 - added support for DC current files from the camera control
2641
2642 - added support for start- and stop-time when merpping report files
2643
2644 - added MReportCC storing the weather data from the CC-REPORT
2645
2646 - added class to fill trainings and test matrices (MTFillMatrix)
2647
2648 - added a filter performing a software trigger (MFSoftwareTrigger)
2649
2650 - Added classes to perform parts of the standard analysis (Jobs):
2651 + MJPedestals
2652 + MJCalibration
2653 + MJExtractSignal
2654 Note: All of them are preliminary!
2655
2656 - Added Iterator to iterate over files giving only the run-number
2657
2658 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2659 the evolution of a sector vs time
2660
2661
2662
2663 *** Version 0.8.3 (2003/12/05)
2664
2665 - adapted Random Forest classes to allow the use with MC
2666 multi-telescope files which can be produced with the coming
2667 camera version 0.7.
2668
2669 - added classes to read and interprete central control report files
2670 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2671
2672 - enhanced merpp (the executable) to support .raw and .rep files.
2673
2674 - added classes for light calibration (MCalibration* and
2675 MHCalibration*) by Markus Gaug. Further work has to be and will
2676 be done soon.
2677
2678 - Added a preliminary 'synchronizer' (MReadReports) which will
2679 replace MReadMarsFile as soon as it is finished.
2680
2681 - Added a tutorial macro demonstrating how report files are merpped
2682 and how they can be read from the root file in the correct order
2683 of time (readrep.C)
2684
2685 - Added a generalized histogram (similar to MH3) called MVsTime
2686 which allows to plot variables (or rules - MDataChain - of
2687 variables) vs time. For an example have a look at tempvstime.C.
2688
2689 - Changed the name of the event trees:
2690 + Events --> Events
2691 + PedEvents --> Pedestals
2692 + CalEvents --> Calibration
2693
2694 - changed name of MTime in the event trees from MRawEvtTime to MTime
2695
2696 - added displaying the sector indices to the mars event display
2697
2698 - Magic Online Analysis (MOnA) implemented in a first version
2699 (see mona.cc, MOnlineDump and MOnlineDisplay)
2700
2701 - added classes to calculate event rate
2702 (preliminary: MEventRateCalc, MEventRate)
2703
2704 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2705
2706 - added classes dealing with the telescope pointing position (MPointing*)
2707
2708 - implemented the 'final' Mars time stamp based on some experiences with
2709 the new 'Synchonizer'
2710
2711
2712
2713 *** Version 0.8.2 (2003/11/10)
2714
2715 - accelerated standard analysis by a factor of 6-8 ...
2716 + doing precalculations in MGeomCam for the pixel area ratio
2717 + creating a look up table for the single pixels in MCerPhotEvt
2718
2719 - added task to calculates weights in case you want to 'change'
2720 the energy spectrum of a monte carlo file
2721 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2722
2723 - added a new executable star which implements the
2724 star.C macro as precompiled executable. Currently a flexible
2725 setup is not possible, but a 'input card' setup will follow.
2726
2727 - Starting to implement Multi-Telescope-Support based on the
2728 upcomming camera version 0.7. The base for a general support
2729 is implemented and the star-functionality is proven to work.
2730
2731 - Replaced Event-Display in and Camera-Display in the Mars GUI
2732 executable by a more convinient display base on MStatusDisplay.
2733
2734 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2735
2736
2737
2738 *** Version 0.8.1 (2003/10/20)
2739
2740 - added signal subtraction for pure on data by means of fitting
2741 the background in the off region or by performing a combined
2742 signal/background fit. Provides necessary histograms for
2743 obtaining energy spectra and a light curve.
2744
2745 - added classes to perform and study the selection of the
2746 2nd Level Trigger on MC data (example in triglvl2.C macro)
2747
2748 - added pedestal calculation
2749
2750 - implemented "democratic cleaning" (tail cut value proportional
2751 to pixel area) according to Wolfgang's suggestion.
2752
2753 - added Sigmabar treatment (calculation and basic histogramming)
2754
2755 - added basic routines to apply padding
2756
2757 - added first implementation of MARS-based source visibility plotter
2758 (needs to be linked against slalib, preliminary version)
2759
2760 - enhanced functionality of data chains: random numbers, conversion
2761 functions and access to MHMatrix objects
2762
2763 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2764 numbers under certain circumstances (runs with 0 events included)
2765
2766 - fixed a bug in the general filter MF (didn't work on some systems
2767 at all)
2768
2769 - fixed a bug in chaining files, which caused the analysis to crash or
2770 ignore files
2771
2772 - implemented more geometry classes describing the parameters used
2773 to simulate the PMT camera
2774
2775 - added new Monte Carlo classes containing the setup of the different
2776 programs in the MC chain.
2777
2778 - added a (preliminary) general task to evaluate chi-square of a given
2779 parameter in an eventloop.
2780
2781 - first implementation of a container describing the observatory
2782 location (Long, Lat, etc)
2783
2784 - added Random Forest - method for g/h-separation
2785
2786 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2787 (this means, that it is compiling, but not yet fully tested)
2788
2789 - added a new status display which can show the present status
2790 of histograms while an eventloop is running (MStatusDisplay,
2791 an example can be found at status.C)
2792
2793 - reorganized directories:
2794 classes describing the image --> mimage
2795 classes containing Monte Carlo Histograms --> mhistmc
2796 classes for Random Forest method --> mranforest
2797
2798 - added (event-)weights to fill histograms
2799
2800 - colors in logging output to screen
2801
2802 - changes to the Image Parameter declaration:
2803 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2804 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2805 + MHillasExt now derives from MParContainer instead of MHillas
2806 --> Files written with the old definition are more or less unreadable
2807
2808 - reading of reflector files
2809
2810 - display data from reflector files in the camera
2811
2812 - implemented currents (and display them in the camera)
2813
2814 - logarithmic scale in camera
2815
2816 - added class to iterate through directory contents (MDirIter)
2817
2818
2819
2820 *** Version 0.8 (2002/11/18)
2821
2822 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2823
2824 - corrected 48(!) wrong entries in the Next Neighbor table of the
2825 Magic Camera (all in the inner part of the outer ring, mostly
2826 missing a single NN)
2827
2828 - Fixed a bug in the table describing the Next Neighbours of the
2829 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2830 have any neighbour)
2831
2832 - changed trigrate.C: now it calculates the pure NSB triggers from
2833 a camera file (generated with no showers), so there is no need
2834 to introduce them by hand in the BgR array (for more details
2835 please ask Abelardo)
2836
2837 - added MHHadronness (and MHadronness) as a general facility to evaluate
2838 the quality of a gamma-hadron seperation method
2839
2840 - changed MWriteAsciiFile to accept rules (MDataChain)
2841
2842 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2843 must be replaced by calles to MWriteAsciiFile::AddColumn and
2844 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2845 changed.
2846
2847 - Implemented generalized event-matrices (one row per event)
2848 (MHMatrix)
2849
2850 - implemented the one dimensional composite probabilities
2851 (MHCompProb, MCompProbCalc, comprob.C)
2852
2853 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2854 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2855
2856 - Added a camera display displaying the pixel numbers to the
2857 event display gui.
2858
2859 - Added Monte Carlo Informations to event display gui
2860
2861 - Changed the camera display to display the pixel numbering
2862
2863 - Added three buttons to the camera display to change the palette
2864
2865 - Added the number of used and core pixels after image cleaning
2866 to MHillas
2867
2868 - Changed the algorithm used in MHillas according to TDAS 02-03
2869
2870 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2871
2872 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2873
2874 - Added fCosDeltaAlpha to MHillasSrc
2875
2876 - The numbers of photons used to calculate fConc and fConc1 in
2877 MHillasExt are now scaled with the pixel size, so that one get
2878 a four times smaller value for the bigger pixels in the outer ring.
2879
2880 - added new task to smooth the camera contents (MCameraSmooth)
2881
2882 - added possibility to use interpolated pixel values for blind pixels
2883 instead of removing it completely from the analysis
2884
2885 - Implemented the possibility to save the whole eventloop with
2886 its setup to a file. This information can be read and from
2887 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2888 and MEvtLoop::MakeMacro. If you find something not working, please
2889 report - this stuff is still in a beta phase.
2890
2891 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2892 file having crab starfield, but also for all following files - fixed
2893
2894 - MTaskList::PrintStatistics can now be instructud to print also the
2895 title, too: use PrintStatistics(0, kTRUE)
2896
2897 - Changed the image cleaning so that pixels with to many 'used'
2898 neighbors are left used (to get rid of 'holes' in events)
2899
2900 - Introduced more output to the camera displays
2901
2902 - Added an array of histograms (eg one hist per run), MHArray
2903
2904 - Added a _preliminary_ version of the reader for CT1 PreProc files
2905 (MCT1ReadPreProc)
2906
2907 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2908 (thanks to Raquel)
2909
2910 - added the first energy estimator (MEnergyEstParam, estimate.C,
2911 estfit.C) using a parametrization
2912
2913 - Added some new Monte Carlo paremeter containers used to store
2914 setup information from the MC chain (MMcConfigRunHeader,
2915 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2916
2917
2918
2919 *** Version 0.7 (2002/04/30)
2920
2921 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2922 the pedestal mean value was saved incorrectly. For files from
2923 this versions we substract 0.5 from the pedestal mean.
2924 WARNING: This may effect your results, so don't wonder...
2925
2926 - First implementation of an algorithm using only triggered events
2927 for the collection area calculation
2928
2929 - Ascii Output can now also be used for parameter containers which
2930 doesn't overload MParCointainer::AsciiWrite
2931
2932 - The Ascii Output is now also capable of writing single data members
2933 of one container
2934
2935 - You are now able to change the order of the values written to the
2936 ascii file
2937
2938 - You can now specify a conversion factor for each data member written
2939 to an ascii file. This may be usefull to change the units of the
2940 data member (eg. degrees instead of millimeters in case of the
2941 hillas parameters)
2942
2943 - Replaced old MHillas by a new structure which allows you to extend
2944 the parameters stored in MHillas very easily:
2945 see MHillas and MHillasExt
2946
2947 - Added classes to handle source dependancy of image parameters:
2948 see MHillasSrc
2949
2950 - Added container (MBinning) to have a standard input for the binning
2951 in different histograms (eg. the Energy bins should be the same in
2952 all histograms)
2953
2954 - Changed Hillas histograms from mm to deg
2955
2956 - Added the flexible binning to the hillas histograms
2957
2958 - Added a filter for the alpha parameter (MFAlpha)
2959
2960 - It is now possible to write single data members of a class object to
2961 an output stream instead of the whole container only
2962
2963 - Added a generalized filter for a data member:
2964 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2965
2966 - Added a generalized Filter parser for more difficult filter rules
2967 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2968
2969 - Added new Monte Carlo histograms:
2970 MHMcEnergyImpact and MHMcEfficiency
2971
2972 - Added many new histograms needed for the flux calculation.
2973
2974 - Added a generalized histograms which can fill and show up to three
2975 data members in either a one-, two- or three-dimensional histogram, eg:
2976 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2977
2978 - Added:
2979 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2980 * calculation of <Theta> as a function of time (MHThetabarTime)
2981 they are needed in the flux calculation in
2982 order to select for a given bin in Theta (or time) the appropriate
2983 effective collection area, which is assumed to be given as a function
2984 of Theta and the true energy
2985
2986 - Added calculation of the migration matrix in the energy
2987 (MHMcEnergyMigration):
2988 the migration matrix describes the migration from the true (E_true)
2989 to the estimated energy (E_est); it is needed to determine the
2990 distribution of E_true from the measured distribution of E_est
2991 by unfolding
2992
2993 - changed the color palette in the camera display to DeapSea.
2994
2995
2996
2997 *** Version 0.6 (2002/01/15)
2998
2999 - Introduce the option of disable pixels (MBlindPixels and
3000 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3001 able to deal with Star Field NSB.
3002
3003 - Fixed a bug in the pedestals substraction
3004
3005 - Introduced verbosity levels
3006
3007 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3008
3009 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3010 work correctly (thanks to Abelardo)
3011
3012 - Introduced correct treatment of the diffuse Night Sky Background
3013 and NSB (MMcPedestalNSB)
3014
3015 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3016
3017 - Introduced MMcRunHeaders which contains monte carlo run informations
3018
3019 - Added a 'Print'-Task (MPrint) which calls the Print function
3020 of a parameter container for each event
3021
3022 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3023
3024 - changes to be more efficient with root 3.02/06
3025
3026 - root 3.02/06 fixes:
3027 + the memory leak when reading MRawEvtData
3028 + loosing more time than necessary to update the progress bar
3029
3030 - MWriteAsciiFile is now capable of writing more than one container
3031 in a line. For example: To be able to write Monte Carlo and
3032 Hillas values (energy and alpha) in one line.
3033
3034
3035
3036 *** Version 0.5 (2001/11/06)
3037
3038 - Added new GUI functionality (Analysis)
3039
3040 - Added a camera display to be able to display events in the camera
3041 together with the calculated hillas ellipse
3042
3043 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3044 object at any state of the analysis, so that the output are several
3045 states
3046
3047 - Fixed a bug in the collection area error calculation
3048 (Thanks to Ciro and Abelardo)
3049
3050 - Fixed a bug which causes merpp to crash in some environments
3051
3052 - Implemented auto enabling scheme for Branches to speed up reading
3053 a lot (see MReadTree and MTask)
3054
3055 - Fixed a bug in the Histogram classes which caused histograms to
3056 be written to a file by MWriteRootFile without request
3057
3058 - changed the object I/O from the old stylish root I/O to the new
3059 'auto evolution scheme' This was done only for classes which are not
3060 yet used in Monte Carlo files, so that these files are still readable.
3061
3062 - Added support for a progress bar in MEvtLoop and MReadTree
3063 (see the Analysis Window in Mars for an example)
3064
3065 - Fixed a bug in the package creation which disturbed the conversion
3066 between a mars version unpacked from a tar file and the repository.
3067
3068 - Changed the code to writer merpped (converted into root format)
3069 raw files, to get faster (around 10%)
3070
3071
3072
3073 *** Version 0.4 (2001/09/20)
3074
3075 - This release is made to compile on a root version >= 3.00
3076
3077 - Fixed a bug which causes MReadTree to read the first file only
3078
3079 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3080
3081 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3082
3083 - Added a task to write several container to a root file (MWriteRootFile)
3084
3085 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3086
3087 - Added calculation of the collection area (MMcCollectionAreaCalc)
3088
3089 - fixed some bugs in the Hillas calculation
3090
3091 - added filters to be able to control the task execution dependent on
3092 a parameter (for example: the number of level 1 triggers in a MC-file)
3093
3094
3095
3096 *** Version 0.3 (2001/04/23)
3097
3098 - Many demo macros added
3099
3100 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3101
3102 - Hillas Calculation added
3103
3104 - Standard image cleaning available
3105
3106 - MReadTree is now able to handle more than one file
3107 (Remark: of the same structure)
3108
3109 - Now we are able to display events in a first version of the
3110 Camera event display. To do this we must run the macro
3111 "macros/readCT1.C" to read data from CT1.
3112
3113
3114
3115 *** Version 0.2 (2001/01/24)
3116
3117 - First Implementation of a Gui to read the raw data. Start the
3118 gui with the command mars.
3119
3120
3121
3122 *** Version 0.1 (2000/12/20)
3123
3124 - First official release 0.1
3125
3126 - Changes:
3127
3128 + changed calling style of MRawPixelIterator from do...while to
3129 while-loop
Note: See TracBrowser for help on using the repository browser.