source: trunk/MagicSoft/Mars/NEWS@ 9342

Last change on this file since 9342 was 9342, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 129.8 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * There is no need to re-run any data because no change took place which
8 could have an effect on the output. However, if you want a
9 meaningful SrcPos plot for your MCs in sponde you must re-process
10 star for your MCs first.
11
12 ;general
13
14 * fixed a few small bugs which could cause the display to crash in ganymed
15 and sponde
16
17 * in sequence file the date can now be omittet. In this case the
18 leading date with the underscore is missing in the expected filename
19
20 ;automation
21
22 * added magnetic field Azimuth direction (ARRANG), currently
23 at ~ -7deg at La Palma
24
25
26 ;database
27
28 * plotdb.php: added default (sequences) for startup, added possibility
29 to set size of plot
30
31 ;merpp
32
33 * added support for Arehucas Version >= 200812140
34
35 ;mars
36
37 * The display now also displays the trigger pattern
38
39 ;ceres
40
41 * added a uniformly distributed one-bin time jitter for the start of the
42 digitization. Otherwise the first photon would be digitized always with
43 the same alignment to the bins
44
45 * Added a plot showing the production height of the photons
46
47 * Moved the particle id from the event header to the run header
48
49 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
50
51 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
52
53 * Added many new options to control the tasks. For deatils see ''ceres.rc''
54
55 * Removed obsolete plots in pedestal and calibration mode
56
57 * Removed the non-NightSky photons from the plots where they are just
58 disturbing
59
60 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
61
62 * The daq event number now represents the readout number
63
64 * The camera ''electronics'' can now be ''switched off''
65
66 * A new tab ''info'' now display basic things like the reflector
67 layout
68
69 ;star
70
71 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
72
73 ;sponde
74
75 * The SrcPos plot for your MCs was so far meaningless because it just
76 displayes the MSrcPosCam data from the input star-files. Unfortunately,
77 this containes was never written to the star-files yet.
78
79
80
81== Version 2.2 (2009/01/30) ==
82
83 ;SUGGESTION
84
85 * This release doesn't contain a major change which is expected to
86 change your results. Nevertheless there are small changes to
87 the calibration which can effect at least the first few hundred
88 events in any (mainly MUX and even more SUM) sequence a little bit.
89 So it is recommended although not necessary to reset your sequences
90 in the database before further processing.
91
92 ;NEW
93
94 * A first implementation of a Monte Carlo simulation program
95 (ceres - Camera Electronics and REflector Simulation) has been
96 implemented. It can simulate a full telescope already including
97 a complete reflector simulation and a flexible trigger and readout
98 simulation. Currently, no perfect setup is implemented and
99 especially the output of the program (data structure) should
100 be considered alpha state. Also the user interface is not yet
101 ready.
102
103 ;general
104
105 * All command line options after -- are now interpreted as
106 arguments (usually everything which doesn't start with a minus)
107 rather than options (usually everything which starts with a
108 minus). This allows to use file names starting with a -
109
110 * In all resource files you can now initialize the random number
111 generator. For details see: MJob::InitRandomNumberGenerator
112
113 * added a new program called ''readcorsika''. It's purpose is (in analogy
114 to readraw and readdaq) to read a Corsika output file (for now
115 only cherenkov output is supported) and print its contents in a
116 human readable form. It can also write the contents of this file
117 into a root-file.
118
119 * The calculation of the maximum distance to the origin in a MGeomCam
120 has been improved (edges might be further away than the sides).
121 This is just a tiny change but it might change the appearance of
122 the radial profiles a little bit.
123
124 * The default binning of the center-of-gravity plot has slightly been
125 increased
126
127 ;Database
128
129 * Added informations about the DC currents (fMinCurrents, fMedCurrents
130 and fMaxCurrents). The values are retrieved from the plots showing
131 the average DC currents of all pixels versus time.
132
133 * Websites with tables have now the opportunity to remove lines
134 ('-' button at beginning of each line) and get all lines back
135 ('+' at top of the column)
136
137 * Websites: added option to query only sequences containing sumtrigger
138 events
139
140 * Websites: added option to group by date (year, month, night) for runs
141 and sequences and enabled that combining of different group-bys,
142 e.g. status, date and source is possible
143
144 ;automatic analyis
145
146 * Rewritten producing plots in the web.
147 New plots, namely the output of plotoptical.C (extinction curve from
148 KVA), plotstat.C (status of the automatic analysis (percentage of
149 processed, analysed data etc.)) and plotusage.C (statistics of the
150 condor usage in the data center) has been are available now next to the
151 plots of plotdb.C
152 Mean values from the plots (output of the macro) are provided in a
153 txt file now.
154 The creation of the plots for callisto, star and ganymed in the web is
155 now steered via database. Consequently the plots are faster and
156 reliable up-to-date.
157 For all plots, a new layout is available facilitating the browsing
158 through the plots and providing additional information on the
159 displayed values. (tabs.php) These plots are linked from the DB
160 websites and the wiki.
161
162 ;statusdisplay
163
164 * The ''Loop'' entry in the menu bar now contains an option to pause
165 the loop and to process single events.
166
167 ;merpp
168
169 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
170 instead of RunHeaders)
171
172 * Now allows to merpp files newer than 2008/09/03.
173
174 * Added fixes for wrong (wrong or double) run- and file-numbers
175 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
176
177 ;callisto
178
179 * Extracting the pulse position for the pulse position check events
180 with sum trigger were denied. This decreased the statistics
181 extremely and therefor the resulting puse position was calculated
182 quite weak. Now sum events pass the calculation if and only if they
183 have also a level 1 trigger.
184
185 * the extraction of pedestal events and pulse position from the
186 first data events is now more automatic and makes sure that
187 a more precise number of events is extracted independent of
188 the ratio with which pedestal events or events with signals
189 are contained in the data.
190
191 * Updated Muon calibration constants for all MUX data (teh changes were
192 all smaller than 5%)
193
194 ;star
195
196 * For the calculation of the effective on time all sum-triggered events
197 were skipped. Now all Level1-triggeres events will pass. This might
198 result in a slight inaccuracy of the effective on time.
199
200 ;ganymed
201
202 * If the source position is more than 1deg away from the camera
203 center an error is raised now.
204
205 * Hopefully fixed the bug ''ganymed crashes when resized''
206
207 ;sponde
208
209 * Fixed a problem which causes the fitted spectral slope to be displayed
210 incorrectly. If you use MJSpectrum::FormFlux in your macros make
211 sure that the parameter 0 of your fit is negative.
212
213 * Added a histogram showing the read source position of your MCs
214
215
216
217== Version 2.1.1 (2008/08/04) ==
218
219 ;Database
220
221 * Added the median number of photo electrons from the calibration
222 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
223 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
224
225 * Added fTotOnTime, which is the on-time as given by the run-headers
226 (in contradiction to fAbsOnTime which comes from CC)
227
228 * Added new primaries for the new data structure (Magic II): for the
229 tables dealing with sequences (SequenceBuild Status, Sequences,
230 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
231 this is the telescope number (fTelescopeNumber) for the tables dealing
232 with runs (RunData and RunProcessStatus) this is in addition the file
233 number (fFileNumber)
234
235 * Added column fPriority to the status tables to be able to steer the order
236 in which the data is processed. As default the run, sequence and dataset
237 number are used.
238
239 ;automatic analyis
240
241 * Adapted scripts to the new data structure: They can handle now different
242 telescopes (getting the information as usual from the database).
243 The paths for Magic 2 are not yet implemented.
244
245 ;general
246
247 * should work now with root 5.20/00 (please note that root 5.20/00
248 we encounter crahses in the status display which are ot yet
249 understood)
250
251 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
252 instead of the base name of the file. This makes them easier to
253 access from the code
254
255 * Default Monte Carlo names in MSequence do not require the _E at
256 the end anymore
257
258 * where abrrevating a sequence file with a sequence number is possible
259 also "telescope:sequence" is now accepted, e.g.:
260 star 2:2000123 --out=output
261 see the programs' help for more details.
262
263 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
264 from the database. See the constructors for more details.
265
266 * MReadTree now supports friends
267
268 * MReadTree can now read also files not written by MARS and store
269 the data encapsulated in emulated MParContainers
270
271 * added a new starguider calibration valid since 15.1.08
272
273 ;showplot
274
275 * showplot can now read more than one file at once. This is especially
276 inetersting if reading files containing pure canvases
277
278 ;merpp
279
280 * we merpp the dc currents now also from the camera reports (they have
281 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
282
283 * In the automatic analysis we omit merpping of the currents from the
284 caco files and use the lower rate camera reports from the cc files
285 instead
286
287 * merpp has been redisigned to allow merpping of the cc-reports
288 of a whole sequence. This allows to design a very simple analysis:
289 mkdir output
290 ./callisto 100776 --out=output
291 ./merpp 100776 output
292 ./star 100776 --ind=output --out=output
293 Instead of the sequence number also sequence files are accepted.
294
295 * Implemented a fix for run-numbers between 1001348 and 1001396
296 which were incorrectly assigned by the cc.
297
298
299 ;callisto
300
301 * added a filter again which was was removed in the last release.
302 it removed the most brightest events. This should not change
303 any analysis result because these events are so bright that
304 they cannot be analysed anyway, but the bad-pixel plots doesn't
305 show outliers.
306
307 * updated muon calibration constants for the periods 51-57,
308 58-63 and 67-
309
310 ;star
311
312 * The camera currents are now displayed with the rate of the camera
313 reports instead of the caco reports
314
315 ;ganymed
316
317 * if mc camera files are new enough (>=8) the source position in the
318 camera is now calculated from the stored telscope and shower
319 orientation (Note, that this might not be suitable in all cases
320 depending on the aim of the study. These case still needs
321 implementation)
322
323
324
325== Version 2.1 (2008/06/18) ==
326
327 ;Database
328
329 * introduced average temperature and wind speed from star-files
330
331 * introduced average values from Pyrometer (mainly Cloudiness)
332
333 * introduced the ratio of accepted calibration events in the
334 calibration run
335
336 * introduced the average rates of the different trigger pattern,
337 e.g. the rate of pedestal and calibration events, from the signal-file
338
339 ;general
340
341 * fixed GroupBy options in plot*.C macros
342
343 * only display KVA points (not the Tuorla points) in plotoptical.C
344
345 * all programs now allow to add resources to the ones from the resource
346 file or overwrite them from the command line. This can be done like this
347 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
348 if something seems to be wrong you can debug what the program is doing
349 using the option --debug-env=3
350
351 * increased the diversity of debug levels. That also means that with -v3
352 you get now less output, i.e. only the output which is important for
353 an analysis. To get more output which helps for debugging try 4, 5 and 6.
354
355 * fixed a problem in the task synchronizing the reading of the reports
356 and the data stream. The effect was that in some circumstances the last
357 events of some trees could have been skipped. Since this is only a
358 very tiny part of the data no severe effect to your analysis results
359 is expected (an exception might be very short, i.e. singel runs,
360 datasets).
361
362 * Dataset file now allow to include the sequence file directly within
363 the dataset file and also allow to exclude single runs from the dataset.
364 (for more details see Class reference of MDataSet)
365
366 * Sequence files now allow for excluding runs from the analysis
367 (for more details see Class reference of MSequence)
368
369 * added code to process the sum-trigger flag
370
371 * the histogram classes MH3 and MHn now support profile histograms
372
373 * the histogram classes MH3 and MHn now support labels at the axis
374
375 * the Random Forest Train-classes (MJTRain*) now store the used datasets
376 in the output file
377
378 * the MFMagicCuts have a new option to allow a linear area cut (for
379 special studies)
380
381 * The liniking of the shared object is now done into a file defined
382 by 'mktemp'. This should be a local file system which accelerates
383 liniking a lot.
384
385 * The code has been prepared for compilation with root 5.18/00d
386
387 * The MHEnergyEst histogram now shows the distribution of
388 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
389 and (Eest-Emc)/Emc vs Emc.
390
391 * fixed mars (event display) for merpped raw-data and MC data
392
393 * adapted the synatx of sequence files to allow for the new run/file
394 scheme. For more details see class description of MSequence
395
396 ;showplot
397
398 * Added support for tiff files
399
400 * Added support for csv files (tables containing tab number,
401 name and title)
402
403 * Tabs now can have a title which is displayed in the postscript file
404
405 * When multiple file are written at once (e.g. pngs from a display)
406 it is now possible to use the tab name and or tab number in the
407 file name. For details see showplos's help.
408
409 ;merpp
410
411 * Implemented cc file version 2008-02-20/0
412
413 * Implemented cc file version 2008-05-19/0
414
415 * With new options merpping can be restricted (in addition to the
416 run-number) also by telescope and file number.
417 For details see "merpp --help"
418
419 * Implemented raw data format 11 (the most important change, except
420 from plenty of changes in the format definition, is the addition
421 of the file-number in the header) If nobody makes a mistake this
422 format should have the advantage that it is by definition forward
423 compatible, so old programs will be able to read newer formats.
424
425 * Added Pyrometer information to default output (stored in a new Tree
426 Pyrometer, needs a complete new merpp, i.e. new calibration)
427
428 * Merpping (also update) can now be restricted to one single report.
429 For example:
430 If you want to update an old file with Pyrometer information call
431 merpp --only=Pyrometer --update
432
433 ;callisto
434
435 * in the pedestal processing now at least 50 processed events are
436 required for succeeding.
437
438 * the signal and calib files now contain also the sequence information
439
440 * the two MPedestalCam in the calib file now have proper names
441 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
442
443 * Both pedestal cams now contain the number of events processed
444
445 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
446 i.e. for the extraction of the calibration pulses basically the average
447 over all events of the first slice instead of all slices was used.
448 Since pedestal and calibration constants are continously recalculated
449 this only effected the very first events of every sequence.
450
451 * For the extraction of the position of the maximum sample now the
452 extraction range is set automatically to the extraction window,
453 before the whole accessible range was used.
454
455 * If the number of samples in the events and the number of samples
456 in the run-header disagrees now an error is raised (this can
457 happen in not well simulated Monte Carlo files)
458
459 * In the case of MUX-data pedestal events with the lvl1 trigger flag
460 could survive into the pedestal calculation -- fixed.
461
462 * Tab "TrigPat" added showing the distribution of the trigger pattern
463 as found in the run-files (normalized with the run length)
464
465 * The selection of events from the trigger pattern has been improved.
466 If the trigger pattern is corrupted events won't pass anymore.
467
468 * Added a new command line option --dev-null to suppress output of
469 Y-files (this is useful for test cases)
470
471 * added a new tab "CalPos" showing the arrival time of extracted
472 interleaved calibration events
473
474 ;star
475
476 * the star file now contains also the sequence information
477
478 * Added a new command line option --dev-null to suppress output of
479 I-files (this is useful for test cases)
480
481 * Tab "Rate" added showing the distribution of the trigger pattern
482 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
483 the Y-files (normalized with the run length)
484
485 * The effective on-time calculation doesn't use events with only
486 sum-trigger anymore
487
488 * The data in the MHWeather tab has been reorganized. The never
489 working solar radiation has been removed and the data from
490 the pyrometer (cloudiness, air and sky temperature) is
491 displayed in addition.
492
493 ;ganymed/sponde
494
495 * Now data points are even shown correctly if they have error bars larger
496 than one sigma. Points with null or negative significances are omitted.
497
498 * DrawNicePlot now allows to set a projection range
499
500 * Updates pointing models. One is applied after the implementation
501 of the new LUTS in August, the other one is applied after the
502 next major change of the pointing model in October. Note that
503 these models are preliminary and give wrong results below Zd=65deg
504
505 ;sponde
506
507 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
508
509 * a new option "--force-runtime" is available. In case of very short
510 datasets (for light-curves) which are in the order of a few
511 minutes the calculated effective on-time is not very acurate because
512 it is quantizised in the order of a minute. Therefore you can switch
513 to using the real run-time instead (remakrt: this ignores any
514 dead-time!)
515
516 * a more analytical way is used to "fill" Monte Carlos into regions
517 of impact parameters which have not been simulated because the
518 trigger efficiency is assumed to be 0.
519
520 * estimated sensitivity curves for hi and lo zenith angles are shown
521 scaled to the correct observation time and collection area
522
523 * the Monte Carlo events after cuts are now written to the output file
524 if an output file given
525
526
527
528 *** Version 2.0 (2007/09/03)
529
530 - database: the position used for the pulse pos check was missing
531 in the callisto output and could thus not be filled into the DB.
532 Also the old values seemed not exactly the PulsePos used for
533 teh check.
534
535 - general: Resource file now allow an Include-Resource, i.e. you can
536 read a resource file with default settings, include it in your
537 resource file and overwrite the settings in your file. More than
538 one include file is allowed. Inclusions can be iterative.
539 Include: mydefaults.rc yourdefaults.rc
540 The resources in the first file have higher priority than the
541 second file.
542
543 - general: Now the output files (calib*.root, etc) also contain the
544 resource file (to check it open it in the TBrowser and choose Print()
545 from the context menu)
546
547 - general: Dataset files now allow to overwrite the default path
548 to search for sequence and data files. Note, that the program
549 option and individual resources will overwrite it. For example:
550 SequencePath: /magic/montecarlo/sequences
551 DataPath: /magic/montecarlo/star
552
553 - general: Fixed a problem with variables in MDataPhrase. It seems
554 that only optimdisp (didn't work) was effected.
555
556 - general: Some improvements to the optim and train processing. For
557 example the ststud window now got a proper title.
558
559 - general: The "Status Display: " was removed from the window title
560 within an Eventloop.
561
562 - general: added a new flexible histogram-class (MHn) which can be used
563 for example in testing after optimizations or training to produce
564 user defined histograms.
565
566 - general: The Random Forest now allows attaching an evaluation
567 function which is applied to its output. This allows to train
568 on whatever you like (eg. train on log10(energy), but return
569 energy)
570
571 - general: The Random Forest training of energy (trainenergy.c) and
572 disp (traindisp.C) has been improved by more graphical output to
573 judge the result.
574
575 - general: The training of energy (trainenergy.C) has been improved
576 a lot by training on a different quantity than energy. It gives
577 a result which is highly independant of the source spectrum
578 and shows lower bias than all other options.
579
580 - general: Dataset files are allowed to contain collections of
581 datasets. For more details see the class reference of MDataSet.
582
583 - general: The default WobbleMode in a datset file now (if not
584 overwritten) is "auto", i.e. wobble mode is set if the dataset
585 doesn't contain off-sequences.
586
587 - merpp: Merpp can read file format version 9 now. Please realize
588 that for file format version 9 the extraction range is different
589 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
590 the first and last 15 slices have been removed from all MUX data.
591
592 - mars: Similar to writing movies you can now select events which
593 should be displayed in your display. Therefore add the following
594 lines to your mars.rc:
595 MFEvtNumber.FileName: ganymed00223552.root
596 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
597 The input file can be a ganymed-file after (ganymed*.root) or
598 before (ganymed*-summary.root) file. For example to select all events
599 from your on sample after cuts (excluding the ThetaSq cut) use
600 MFEvtNumber.Selector: DataType.fVal>0.5
601 To show all events from your on-sample after quality cuts
602 use the summary file instead.
603
604 - mars: new ways to call mars are implemented. Instead
605 of calling
606 mars filename.root
607 you can now also use
608 mars sequence.txt
609 or
610 mars sequence.txt inputpath
611 or replace sequence.txt by the sequence number if the default
612 sequence file should be used.
613
614 - mars: The default size has been increased
615
616 - mars: There are two new heckboxes which allow to switch off
617 the calculated image parameters
618
619 - callisto: was broken for MCs... fixed.
620
621 - callisto: improved calculation of spline coefficients a lot. This
622 leads to a further improvement of the event rate calibrating MUX
623 data of about 15% (175evt/s instead of 150evt/s)
624
625 - callisto: finally the raw data we read is now real 16bit (with
626 10bit precision) for MUX data and not a stripped 8bit number
627 anymore. Due to scaling of the numbers (without precision loss
628 into an [0-256[ range, the final numbers for pedestal, pedestalrms
629 and extacted signal don't change. However, at all places where
630 raw data is directly accessed (eg. saturation and variation
631 limits in the signal- and pedestal-extraction) the numbers
632 refer still to the data's 16bit range.
633
634 - callisto: The maximum arrival time difference used in the bad
635 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
636 for both, old FADC and MUX-FADC, data.
637
638 - callisto: Be aware that callisto is now calibrating the arrival time
639 in nanoseconds rather than time slices. Also all following tasks
640 have been changed to assume ns units now. If you star data
641 calibrated with an older version it might be necessary to adapt
642 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
643 to obtain optimal results. The plot in the PulsePos tab
644 will now be in ns, too. This might also mean that the Muon
645 analysis in star might not work as perfect as expected as long
646 as old files read in.
647
648 - callisto: The calibration constants of earlier updates got lost
649 somehow. All constants have been updated.
650
651 - star: The PSF is now determined from the profile of the ArcWidth
652 instead of arcwidth/radius. The old way gave to much weight
653 to the bins with low statistics. The reference lines have been
654 updated.
655
656 - star: For speed reasons events suitable for the muon analysis
657 are now also preselected by fConcCOG<0.1 which seems to be a very
658 good preselector for muons.
659
660 - star: is now calculating a new timing parameter the Slope along
661 the major and minor axis of the shower. Therefore a numerical
662 solution of a line-fit is used. To use MHillasExt.fSlopeLong
663 and MHillasExt.fSlopeTrans don't forget to multiply it with
664 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
665
666 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
667 have been removed from MNewImagePar. They have never been good for
668 anything.
669
670 - star: Implemented a new recursive algorithm which is supposed to be
671 faster. Also implemented new cleaning oiptions, which are:
672 + CleanLevel0:
673 The cleaning level above single core pixels can be kept
674 + KeepIsolatedPixels:
675 Define whether single core pixels should be kept
676 + TimeLevel1:
677 The coincidence window in nanoseconds to single used neighbors
678 + TimeLevel2:
679 The coincidence window in nanoseconds to two used neighbors
680 + PostCleanType:
681 MOde in which a time dependent post cleaning should be applied
682 0: No post cleaning
683 1: Require for each used pixels at least one used neighbor
684 within a time-window of CleanLevel1
685 2: Require for each used pixels at least two used neighbor
686 within a time-window of CleanLevel2
687 3: Require first two and second one used neighbor
688 within a time-window of CleanLevel1 and fCleanLevel2
689 respectively
690 + RecoverIsolatedPixels:
691 - recoveres isolated core pixels if they have a used neighbor
692
693 - mars/star: The new default cleaning is:
694 + CleanLevel1: 6.0
695 + CleanLevel2: 3.0
696 + CleanTime1: 1.75
697 + CleanTime2: 1.75
698 + PostCleanType: 3
699
700 - star/ganymed: The old spark-cuts have been replaced by new ones.
701 These new spark cuts have been cross checked with the sequences
702 84720 (before splitter), 101041 (after splitter) and 223539 (new
703 FADCs). In all cases they seperate pretty well, but of course not
704 perfect. Monte Carlos have suggested to tighten the cuts a little
705 bit further at low sizes. This has been done.
706
707 - ganymed: IMPORTANT - The spark cuts have been changed to match
708 all available data more or less well. This might mean that for
709 YOUR data there are still sparks visible.
710 Whenever you do an analysis you have to make sure that NO sparks
711 survive your cuts!
712
713 - ganymed: The old hadronness and size cuts have gotten new indices
714 (10, 11). The old indices 8 and 9 now mean an additional condition
715 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
716 If you want to switch off this cut just move the line far away enough,
717 e.g. by setting c[9] to -500. Please update your ganymed.rc files
718 accordingly!
719 The unit of c[9] is deg. It is the dist at which your cut will
720 cross the slope==0. The unit of the slope is ns/deg. So if
721 you readin files calibrated with an older Mars-version you
722 have to adapt the default value for c[9] to the FADCs:
723 - Multiply by two for the MUX FADCs (run number > 200.000)
724 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
725 - Multiply by 42 for the meaning of life (run number = 200.000)
726
727 - ganymed: The old Cut0 is now called CutQ and is calculated before
728 the source position is caluclated. If you need a quality cut
729 including source dependant data (be very carefull with this!)
730 you have to use Cut0 instead.
731
732 - ganymed: now properly supports three off regions in wobble mode.
733 It will be the default from now on in ganymed_wobble.rc. To change
734 the number of off-regions use
735 NumOffSourcePositions: 1
736 in your ganymed.rc. Also by default no off-theta cut will be done
737 anymore so that you will get a background level higher than the
738 signal level in your ThetaSq plot for ThetaSq>0.2.
739 Due to this be carefull changing the scaling mode away from
740 "None". You will underestimate your signal if your scale interval
741 is not properly set.
742 (Rem: ThetaSqN is no longer needed)
743
744 - ganymed: is now storing the events of all (on- and off-)
745 source positions even in the case of more than one off-source
746 position. This should allow sponde to work properly and the
747 energy estimation is done correctly in all cases (without any
748 "nearest position" trick)
749
750 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
751 with a real pointing model for the starguider is done, calibrated
752 with more than thousand tpoints taken from this date on.
753
754 - ganymed: was broken for Wobble-MCs... fixed.
755
756 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
757 has changed. Note that your old ganymed.rc will be incompatible
758 with the new algorithms! Please check the ganymed.rc files and
759 the class description of MFMagicCuts for more information.
760 It is recommended at the moment to use identical Disp-Parametrizations
761 for on/off- and wobble-mode. If cuts are optimized only
762 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
763 should be optimized. All other values should be kept as they are.
764 If you want to do an anylsis without timing a parameters, you can
765 switch off the timing cuts by seeting parameter 7 to a very small
766 value (eg. -99). To remove the slope parameter from the disp
767 paremtrization set parameter 8 to 0.
768
769 - ganymed: The distribution of observation time versus zenith
770 angle is now shown for off- AND on-data.
771
772 - ganymed: The contents of the source position plot are no longer
773 averaged, thus a lot of (fake) events between the two wobble
774 positions have disappeared.
775
776 - ganymed: There is a new tab "CutT" it contains the VsSize plots
777 with the CutT, whihc is defined in ganymed.rc, applied. It
778 is resonable to use your theta-cut for it, to see if there is
779 something strange (sparks!) in your signal-region.
780
781 - ganymed: To choose a dataset from a collection in a dataset file
782 use the new command line option "--dataset=12345"
783
784 - optim, sponde: should now properly support three off-regions.
785 Just produce your ganymed summary files with three off-regions.
786 optim and sponde will automatically get all off events from
787 all off-regions from this file. Please do not forget to
788 set the scaling in optimwobble.C properly:
789 fit.SetScaleUser(1./3);
790 it is not yet read in automatically (will follow soon).
791 In the case of fixed Scale you can also use
792 cuts.SetThetaCut(MFMagicCuts::kOn);
793 no off-cut needed.
794 Be carefull in case of three off-regions when switching on
795 scale mode. Make sure that the scale interval is set correctly.
796
797 - sponde: sponde.rc and sponde_onoff.rc are now idetical
798
799 - sponde: the resouce files have been rewritten with a lot of
800 comments and a well working parametrization for an energy estimator
801
802 - sponde: In the estimated energy versus monte carlo energy plot the
803 contents where exchanged.... fixed.
804
805 - sponde: the so called "accurate"-mode has been removed. It didn't
806 give any improvement in accuracy, only decreased execution speed.
807
808 - sponde: the so called "simple"-mode has been removed. It didn't
809 give any improvement in simple.
810
811 - sponde: the so called "refill"-mode has been removed. It was anyhow
812 not implemented.
813
814 - sponde: now checks whether the theta distribution of your on-data
815 and the theta-distribution of your Monte Carlo sample (after
816 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
817 sample is incomplete) execution is stopped. Execution can be forced
818 using the new option --force-theta. Use this option with care!
819
820 - sponde: Proper collection areas can now be constructed also from
821 Monte Carlo samples generated with different maximum impact
822 parameters. Note that in previous version you neither got
823 a warning or failure, nor was there any obvious sign that the
824 collection area was overestimated due to usage of files with
825 different maximum impact parameters.
826
827 - sponde: If MC files with different lower energy limits are used
828 the primary MC spectrum is artificially completed down to the
829 lowest energy used at all. WARNING: that this gives correct
830 collection areas ONLY if none of the events in this region would
831 survive your cuts at all.
832
833 - sponde: the output file now contains more information about
834 the spectrum (eg. the full 2D collection area histogram).
835 Note, that this information can only be written to the file
836 if it is stored automatically via command line argument.
837 If you only store the status display from within the display
838 the information is lost.
839
840 - sponde: added a new tab "Disp". It shows the residual of the disp
841 (Disp-Dist) versus several parameters and it is meant to judge the
842 quality of the disp estimator. In the ideal case the residual is zero
843 and doesn't depend on any variable. The tab is displayed after
844 CutQ and Cut0.
845
846 - sponde: added a new tab "Energy". It shows the residual of the
847 energy (lg(estimated energy)-lg(monte carlo energy)) versus
848 several parameters and it is meant to judge the quality of the
849 energy estimator. In the ideal case the residual is zero
850 and doesn't depend on any variable. In reality even a good estimator
851 can show residuals versus Monte Carlo energy. The tab is displayed
852 after all cuts.
853
854 - sponde: added a new tab "EventDist" showing the unweighted real
855 absolute number of events of your sample after cuts. This tells
856 you how many events with this energy you had in your MC files.
857 The same information you get from the error bars of the weighted
858 histograms, but this is less intuitive.
859
860 - sponde: The spectrum plots now show the crab- and 1553-spectrum
861 for comparison. It is not meant to show these curves in
862 publications, they are only for production.
863
864 - sponde: The OriginalMC tree with the events produced by corsika
865 is now processed only once
866
867 - sponde: Finally fixed most annoying bug, which has effected the
868 last bin of the collection area. It was the problem that binnings
869 of root histograms are from 1 to n (included) but there was a C-like
870 loop in sponde from 0 to n (excluded). Now the loop also includes
871 correctly under- and overflow-bins. The worse thing with this is,
872 that for the events in the highest bin not only the bin-content
873 was wrong, but also the weights applied to these events, which could
874 in pricipal effect also other parts of the distribution (eg. due
875 to energy estimation). Fortunately it effected only a few events
876 in most cases.
877
878
879
880 *** Version 1.2 (2007/05/14)
881
882 - database: The database now has two new values Unsuitable50 and
883 Unsuitable01. They express the number of pixels which are
884 unsuitable for more than 50%, respectively more than 1%, of
885 all calibrated event. It is a more accurate number than the
886 previously used numbers, because they only take the first
887 calibration (ignoring the interleaved calibrations) into account.
888
889 - database: The database now has two other new values UnsuitableMax and
890 DeadMax. They express the maximum number of pixels which were
891 unsuitable, respectively dead, during the sequence. Because
892 of high pedestal rms (cars passing) a few events with very high
893 numbers of unsuitable pixels can happen. Not to suffer from this
894 effect we don't take the highest 0.1% of the numbers into account.
895
896 - general: fixed a bug which caused callisto and star to stop working
897 properly because the callisto output was currupted
898
899 - general: a script called scripts/makemovie has been added which
900 simplified the process of producing several movies from a single
901 sequence with different setup.
902
903 - callisto: Some more code cleanup. Started to remove old obsolete
904 code from cvs.
905
906 - callisto: The extraction of the pedestal with the extractor was
907 not random. It seems that extracting at one position is still biased
908 (for example in the first or last slices we could still suffer from
909 switching noise) Now it is completely random.
910
911 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
912 pedestal files) individual pixels could be skipped due to high
913 variations. This was already the case for the pedestal extraction
914 from the lo-gains since the beginning and properly handled
915 there, but was introduced in the extraction from the pedestal files
916 a while ago. To calculate the average value it was still divided
917 by the number of events procesed not by the number of summands
918 really summed. This let to a pedestal which was a tiny amount too
919 small (for a few piels in the order of 0.1%). This led to an slightly
920 positive offset of the randomly extracted pedestal for a few pixels.
921 I doubt that this has a big effect on the result, because the effect
922 on the individual numbers is quite small. Due to this it is suggested
923 that you rerun your calibration to make sure you are without any
924 avoidable bias.
925
926 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
927 the median rms of the absolute arrival time and expressed in significance
928 levels. This replaces the old meaning of an abolute upper limit. An
929 absolute upper limit doesn't make much sense, because in our data
930 all arrival times are shifted at the same time (in fact it might be
931 a shift of the artificial trigger w.r.t. to the light flash).
932
933 - callisto: Added a new tab "BadPixTm" which shows the time evolution
934 of the number of unsuitable pixels over the whole sequence. This
935 is usefull mainly to judge if an intermediate calibration had
936 problems.
937
938 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
939 of the number of dead pixels over the whole sequence. Dead pixels
940 in this context are unmapped pixels, i.e. pixels which could not
941 be interpolated, and thus are ignored in the further analysis.
942
943 - callisto: It is now possible to use the position of the maximum
944 of the spline as arrival time instead of the leading edge even
945 when using the integral for the signal. Therefor set the extraction
946 type to kIntegralRel ("IntegralRelative") and the relative height
947 ("HeightTm") to -1:
948 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
949 MJPedestalC1.ExtractSignal.HeightTm: -1
950
951
952
953
954 *** Version 1.1 (2007/04/27)
955
956 - general: The new class MGeomCamDwarf contains the camera geometry
957 for our prefered Dwarf camera and can be used to create general
958 geometries of roundish or hexagonal cameras.
959
960 - mars: The default cleaning is now abolute 8.5/4.0.
961
962 - mars: The resource file mars.rc now contains examples for MUX data
963
964 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
965 data containing only 10-bit information is still cooked down to
966 8-bit, by cutting away the lowest 8-bit.
967
968 - merpp: When reading raw data the data is now stored in a single
969 array. The lo-gain array is obsolete. The interface stays the same.
970
971 - callisto: To process the new MUX data use the resource file
972 callisto_mux.rc
973
974 - callisto: The -root and -raw options to read merpped raw data have
975 been removed
976
977 - callisto: If the -mc option is given the sequence-name can now be
978 replaced by the MC sequence number
979
980 - callisto: If the sequence file contains "MonteCarlo: Yes" the
981 -mc option can now be omitted
982
983 - callisto: Started further simplification by removing obsolete
984 dependancies on MCalibIntensity*Cams.
985
986 - callisto: removed unsused intensity calibration from MJCalibration
987 for further simplification
988
989 - callisto: for simplification removed references to
990 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
991 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
992 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
993 (this should at minimum change nothing at all, and at maximum
994 improve thing if these containers where somewhere not handled
995 properly)
996
997 - callisto: Added the option to write an event movie. Please use
998 this option with care (huge files) but exessively to understand
999 our events. For further documentation please refer to the
1000 IACT wiki
1001 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1002
1003 - callisto: Improved binning for the pulse position check histogram
1004
1005 - callisto: The code calculating the pulse position checknow takes
1006 the pedestal into account
1007
1008 - callisto: The arrival time is now stored with full precision this
1009 helps to get rid of artefacts in histograms. For the signal this
1010 is not necessray because it is displayed in log-scale anyhow
1011
1012 - callisto: Fixed a problem with internal exclusions. Pixels which
1013 have once been marked as unsuitable didn't get the necessary
1014 histograms filled anymore to be rechecked with each interleaved
1015 calibration.
1016
1017 - callisto: The relative arrival time resolution (the rms of the
1018 relative arrival time offset) is now checked against its
1019 median and the median deviation, instead of the average
1020 plus an absolute offset.
1021
1022 - callisto: The relative arrival time offset is now calculated
1023 w.r.t. its median not w.r.t. to an artificial reference pixel.
1024
1025 - callisto: The relative time calibration now marks pixels with
1026 outlaying offset as unsuitable
1027
1028 - callisto: The interleaved relative time calibration has been switched
1029 on. The advantage is that pixels which are marked as outliers
1030 now can recover. An improvement over time is not expected, because
1031 the relative time calibration seems stable.
1032
1033 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1034 option can now be omitted.
1035
1036 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1037 or the option "-mc" is specified as default the monte carlo datacenter
1038 paths (/magic/montecarlo/...) are used if not overwritten in the
1039 dataset file.
1040
1041 - ganymed: The output files now contain run- and event-number for all
1042 events, accessible as RunNumber.fVal and EvtNumber.fVal
1043
1044 - ganymed: Added a plot showing the source position in the camera also
1045 for wobble mode
1046
1047 - ganymed: In addition to the existing task which can be setup to
1048 be executed after Cut1 a final task called "EstimateEnergy"
1049 has been added, executed before writing the final output
1050 (ganymed00000000.root). The task setup in all three cases
1051 can be choosen individually. (For all three(!) cases you
1052 can for example choose MRanForestCalc. For examples see all
1053 sponde*.rc and all ganymed*rc)
1054
1055 - ganymed: If a container "MEstimatedEnergy" is found in the
1056 parameter list (eg. because it was setup by MEstimateEnergy)
1057 it will be written to the output file.
1058
1059
1060
1061 *** Version 1.0 (2007/02/16)
1062
1063 - database: Website to plot values from the database has been added.
1064
1065 - database: The rate of spark events as found by star is now kept
1066 and the rate after cleaning is now with spark events subtracted
1067
1068 - general: The changes to the interpretation of phrases lead to
1069 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1070
1071 - general: Added example files how you can create your own calendar
1072 (eg. as christmas present) with Mars. Just run
1073 root macros/tutorials/calendar.C
1074
1075 - general: Added a possibility to display grouped data in the plotdb.C
1076 macro (and similar macros). This allows to plot hourly, nightly,
1077 weekly, monthly and yearly averages.
1078 For more details see the plotall function of the macro
1079
1080 - general: fixed the error display of the camera display. It showed
1081 wrong results.
1082
1083 - general: fixed a memory leak when reading many MStatusDisplays
1084
1085 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1086 between a spherical and a parabolic mirror
1087
1088 - callisto: We have a new pulse position check which takes the properties
1089 of the extractor automatically into account. So no need to set
1090 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1091 left is done. If possible the lo-gain extraction start and hi-gain
1092 extraction end is changed accordingly. If no proper extraction range
1093 can be set (hi-gain too much to the left) an error is raised.
1094
1095 - callisto: New swapped pixels have been found and corrected
1096
1097 - callisto: Redone the signal extraction this includes:
1098 + Unified the algorithms to extract the pedestal for all pedestal
1099 extractions done
1100 + Unification of hi- and lo-gain into one array
1101 + Unification of hi- and lo-gain extraction for Spline and
1102 Digital Filter (means now exactly the same algorithm is used,
1103 not a copy-and-pasted one)
1104 + Store pedestal subtracted data in a common place
1105 + Improved extraction algorithms. If the algorithms search a
1106 maximum but don't find one they don't return the maximum anymore
1107 + Improved the extraction such that a information for signal
1108 and time which is consistent is returned
1109 + replaced the numerical spline with a (not slower) analytical
1110 solution
1111 + Lowered the saturation limit from 250 to 245 to make sure that
1112 we are far away in all pixels from problems with the clock-noise
1113 + The start of the lo-gain extraction is calculated from the hi-gain
1114 arrival time. In case of saturation an estimation is used.
1115 + the hi-gain window was extended to slice 16. This allows extraction
1116 of very late pulses in single pixels or of huge hadron showers.
1117 + Now uses the lo-gain extraction range for pedestal extraction,
1118 not the hi-gain range in the lo-gain
1119
1120 - callisto: New hi-/lo-gain calibration constants have been produced
1121 for all periods from the statistic of the whole period. They are
1122 now used automatically depending on the periods. The old constants
1123 where deviation in avarega about 2%-3%. The constants are very
1124 stable from period to period (<<1%) except for exchanged channels.
1125 In a few cases the constants used so far were off by 1%-2% (maybe
1126 temperature effects?)
1127
1128 - callisto: To gain obsolete space we do not write the
1129 MPedestalFundamental anymore. Also calibration and bad pixel
1130 treatment is not done for it anymore because it has never been used.
1131
1132 - callisto: Fixed a bug in the seuqence handling which caused the
1133 light condition to be ignored
1134
1135 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1136 basically the same as "Cleaned" but the distribution devided into
1137 the events fullfilling a spark cut or being rejected by it.
1138 This cut can be changed from star.rc (see example inside) by
1139 the "SparkCut" directive
1140
1141 - star: Star displays now the average individual pixel-rate (IPR) versus
1142 time and the average discriminator threshold (DT) of all pixels.
1143
1144 - optim: fixed a problem with the optim-macros which was due to a bug
1145 in the new phrase parsing
1146
1147 - ganymed: To get a nice FalseSource plot (instead of the all-information
1148 debug plot displayed as a standard plot) use the context menu
1149 somewhere between the two upper plots, click on "DrawNicePlot"
1150 and enjoy the result. (It is the same context menu which contains
1151 the other options)
1152 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1153
1154 - ganymed/optim/train: The cut program, trainings- and optimization
1155 macros could run with less files found than expected from the
1156 sequence-files. No the execution is stopped in this case.
1157
1158 - ganymed: now stores the dataset in the output file with all information
1159 contained (as sequence number, sequence path, data path) so that the
1160 used dataset file can be recreated complete from the output
1161
1162 - sponde: now also allows the uasge of random forest
1163
1164 - sponde: added a plot showing the cut efficiency
1165
1166 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1167 errors (eg. effecting the collection area) because the errors of the
1168 two histograms were swapped in the calculation, which makes a difference
1169 in the case the histograms contains weighted events. Aditionally the
1170 totalarea was incorrectly taken into account, which results in too small
1171 errors, which makes a difference at low statistics were the errors
1172 or the collection area dominate.
1173
1174
1175
1176 *** Version 0.10.3 (2006/10/23)
1177
1178 - database: Implemented ObservationMode flag in websites.
1179
1180 - database: For sequences there is now also the stoptime available on the
1181 websites.
1182
1183 - database: Removed ManuallyChanged flag from sequence-info websites,
1184 as it is not needed anymore with the new sequence building algorithm.
1185
1186 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1187 Class for calculation of confidence intervals (upper limits).
1188 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1189 Please read the class instruction of TRolke for more information.
1190
1191 - general: The programs now return 0xfe if the requested resource file
1192 doesn't exist.
1193
1194 - general: Errors comming from root itself are now not output to
1195 stderr anymore but to our default (colored) log-stream.
1196
1197 - general: Changed the interface to TFormula such that now everything
1198 is parsed by TFormula, which should allow to use phrases even
1199 without paranthesis correctly parsed.
1200
1201 - callisto: replaced the AdHoc number of effective integration slices
1202 in the digital filter by an average of the correct number, averaged
1203 over all possible set of weights. This also gives correct numbers
1204 for the lo-gains which were totally wrong before.
1205
1206 - callisto: drastically reduced memory consumption by not storing
1207 all intermediate calibration results in memory anymore (we might
1208 write them into a file in the future)
1209
1210 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1211 debug plot displayed as a standard plot) use the context menu
1212 somewhere between the two upper plots, click on "DrawNicePlot"
1213 and enjoy the result. (It is the same context menu which contains
1214 the "DrawAll" option)
1215 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1216
1217
1218
1219 *** Version 0.10.2 (2006/10/15)
1220
1221 - general: changed the building of the sequence files such, that
1222 the source-/project name in case of wobble-sources is not the
1223 source/project of the first data run anymore but the new generalized
1224 wobble source/project
1225
1226 - general: Added some functions to MAstro to calculate sun and
1227 moon properties
1228
1229 - general: Added two new macros (starvisday.C and starvisyear.C)
1230 which allow to plot the visibility of several stars in one day
1231 or of one star along one year
1232
1233
1234
1235 *** Version 0.10.1 (2006/10/11)
1236
1237 - general: HTML logging output was distorted... fixed.
1238
1239 - general: Changed the writing of the sequencefiles such that only
1240 as many pedestal files as giving at least 1000 pedestal events which
1241 are nearby the first calibration run are used as pedestal runs
1242
1243 - sponde: In the calculation of the collection area(s) and the
1244 distribution for MOnte Carlo and estimated energy the error
1245 calculation was wrong because root didn't take the errors
1246 properly into account... fixed.
1247
1248
1249
1250 *** Version 0.10 (2006/10/10)
1251
1252 - general: all executables now check consistency of the root version
1253 installed with the root version used for compilation. The return
1254 code in this case is 255.
1255
1256 - general: The algorithm to build seqeunces has been redesigned
1257 completly. It is now more flexible in terms of a resource file
1258 resources/sequences.rc which can be used to partly overwrite
1259 the default algorithm and defined the important part of the
1260 algorithm. It also takes correctly into account several ways
1261 of taking wobble-data. Currently the new algorithm doesn't take
1262 the number of pedestal events anymore into account (so a sequence
1263 could have much less than 1000 pedestal events and data runs are
1264 no-more used instead)
1265
1266 - general: a lot of small changes to make the code compatible with
1267 root 5.12/00 and gcc 4.1
1268
1269 - general: Fixed some warnings thrown if more warnings are switched
1270 on in the compiler
1271
1272 - general: Added a function to MMath which returns the Median of
1273 the distribution abs(y[i]-median) but at 68:32 division instead
1274 of 50:50, which is somehow the median counterpart of the rms.
1275
1276 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1277 even if they are compressed with gzip (recommended compression
1278 is with "-1")
1279
1280 - showplot:
1281 + batch mode creation of image files now works with root 5.12/00
1282 + added support for writing bmp (though it never produces
1283 bmp which can be read by programs like xv or gimp)
1284 + added support for xml
1285 + added new option to start the display with a different size, by
1286 --display-width=nnn or --display-height=nnn
1287 + added options to define the canvas size when the display is started
1288 --canvas-width=nnn or --canvas-height=nnn
1289 the option can also be used for batch-mode conversion
1290 + added an option which automatically fits the display size to the
1291 desktop-size: --auto-size
1292
1293 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1294
1295 - merpp: allow the reports to have 1000ms due to a bug in the camera
1296 program.
1297
1298 - callisto: New swapped pixels have been found and corrected. For
1299 details see MRawRunHeader::FixAssignment()
1300
1301 - callisto: Callisto now raises an error if one of the input files could
1302 not be opened.
1303
1304 - callisto: In some rare cases it could happen that in the signal
1305 extraction of the digital filter the extractor returned nonsense
1306 results due a wrong initializion of a variable (this happens in
1307 cases in which the extracted signal is exactly zero or the
1308 digital filter couldn't slide because of a too small extraction
1309 window, which could happen in the lo-gain extraction)
1310
1311 - callisto: The lo-gains have been marked as valid in some cases
1312 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1313 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1314 smaller than the number of slices (fLoGainWindowSize) needed
1315 by the lo-gain extractor
1316
1317 - callisto: Updated absolute calibration constants (muon calibration)
1318
1319 - callisto: fixed a bug which caused the hi-gain saturation not
1320 to be handled properly in the spline (the position of the
1321 saturation was calculated incorrectly)
1322
1323 - callisto: fixed a bug which gave weird results if hi- _and_
1324 lo-gain could not be extracted properly. In some cases hi-
1325 and lo-gain have not been extracted at all and the random result
1326 got calibrated. In other cases the hi-gain was saturating and the
1327 lo-gain has not been extracted. For this a completly arbitraty
1328 scale factor was applied to the result from extracting the
1329 charge of the saturating hi-gain.
1330
1331 - callisto: improves handling of extracted signal if lo- and/or
1332 hi-gain could not be extracted properly. If no appropriate
1333 calibration of either the signal or the arrival time is possible
1334 the pixel is now markes as unsuitable instead of estimated.
1335
1336 - callisto: Fixed a problem in the spline extraction which gave
1337 weird results if the signal was extracted from the first (and
1338 highest) slice (as a workaround extraction from the first
1339 slice has been forbidden)
1340
1341 - callisto: Fixed a bug regarding the use of the QE which doesn't
1342 effect the result because the default is used anyhow.
1343 (The bug was there since 14/07/2005)
1344
1345 - callisto: Changed the default for fgLoGainStartShift to -2.4
1346
1347 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1348 factors to be always 10 for all pixels as soon as the first
1349 calibration update has happend.
1350
1351 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1352 was off by more than one slice (which gives wrong values for
1353 pixels which have saturated the hi-gain) This was a problem
1354 mainly for timing studies, not so much for the automatic standard
1355 analysis. Also the values for the Spline have been changed slightly:
1356 + Digital Filter from 1.70 to 0.95
1357 + Spline from 1.39 to 1.30
1358 The numbers were sorted out by an extensive test in the
1359 test-database.
1360
1361 - callisto: Removed the tab showing the average calibrated arrival
1362 time. It never gave useful information.
1363
1364 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1365 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1366 and both were extracted because the hi-gain was above the
1367 LoGainSwitch.
1368
1369 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1370 lo-gain pulse position (after application of LoGainOffset, which
1371 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1372 have saturated and both were extracted because the hi-gain was above
1373 the LoGainSwitch.
1374
1375 - callisto: After extensive tests a new threshold level for determination
1376 of the pulse position has been found at 50phe. This is due to the
1377 fact that for lower pulses the arrival time changes its average
1378 behaviour dramatically. It tends to the average of the extraction
1379 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1380
1381 - callisto: Added two more plots to the calibration part. The average
1382 extracted signal and the average extracted arrival time as
1383 extracted by the signal extractor (This can help debugging problems
1384 because it doesn't involve a fit)
1385
1386 - star: changed the fit for the effective on time such that initial
1387 values are calculated automatically now instead of using build
1388 in values. This makes the fit more indepedant of the underlaying
1389 rates. With a test of ~350 sequences in the test database it could
1390 be shown that the new fit gives the same result +/-1sek.
1391 The highest deviation was +5s the lowest -10s. You can now control
1392 the bahaviour with two resource values:
1393 MHEffectiveOnTime.FistBin: 3
1394 MHEffectiveOnTime.NumEvents: 12000
1395 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1396 from the resulting gamma candidates
1397
1398 - star: The Center histogram in MHHillas is now by default displayed
1399 with the colz draw-option
1400
1401 - ganymed: now produces valid error codes if failed
1402
1403 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1404 with the option "hadronness" instead of "area" or "both" if
1405 you want to use both cuts. The hadronness cut includes a fixed
1406 cut in hadronness (index 8) and a fixed cut in size (index 9).
1407
1408 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1409 the M3Long of the anti source to be not properly evaluated
1410 (actually is was evaluated as a unique random number) in case
1411 of optimization with anti-theta cut switched on. This might have
1412 lead to improper, but not necessarily wrong, optimization results.
1413
1414 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1415 how to use random forest
1416
1417 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1418 ganymed_onoff.rc. Seems to be unintentional that they were different.
1419
1420 - sponde: Since the introduction of the possibility to define a
1421 normalization energy instead of using the integral the default
1422 was not using the integral anymore but a normalization energy of
1423 1GeV. It is now the integral again.
1424
1425 - sponde: Fixed a problem in the weighting which did not allow
1426 a MC slope of -1.
1427
1428
1429
1430 *** Version 0.9.6 (2006/05/24)
1431
1432 - general: changed the binning of the azimuthal profile of the camera
1433 such that it is aligned with the 60deg boundaries.
1434
1435 - merpp: better handling of problems with the TH, TD part of the
1436 CC-REPORT for files older than 200507190 and 200412210
1437 respectively
1438
1439 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1440
1441 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1442
1443 - callisto: if an arrival time is extracted outside the fadc range is
1444 was set to the boundary before. Now a random number is assigned
1445 instead to avoid unfortunate coincidences of arrival times just
1446 by this arbitrary value.
1447
1448 - callisto: added a new option to callisto.rc which allows
1449 to set the maximum arrival time difference allowed for the
1450 badpixel algorithm to determin whether a pixels belongs to a shower:
1451 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1452
1453 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1454 to 0.9 as suggested by Stefan due to a recent study on the fraction
1455 of pixels surviving the image cleaning
1456
1457 - callisto: switched off error in case of "pulse is too much to the left"
1458
1459 - callisto: The extraction window is not adapted anymore. This means that
1460 the pulse is extracted from the full range. The draw-back is that the
1461 background (pedestal) will become slightly higher. Switching on/off
1462 the PulsePosCheck in the callisto.rc only effects filling the
1463 histograms.
1464 WARNING: If the pulse is too much to the left data is calibrated!
1465 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1466 in the database to make sure that your data is valid!
1467
1468 - star: Show also the number of stars correlated correctly by the
1469 starguider
1470
1471 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1472 than one off-source region in wobble-mode. To use it add the following to
1473 your ganymed_wobble.rc:
1474 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1475 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1476 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1477 + Cut1.ThetaCut: None
1478 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1479
1480 - ganymed: in the case the latest report is older than a default (currently
1481 one minute) and the current report will be skip the starguider
1482 correction and calibration will be reset. The maximum age can be
1483 setup from ganymed.rc by (minutes):
1484 MPointingDevCalc.MaxAge: 1.5
1485
1486 - ganymed: A first implementation showing all size-bins for the theta-sq
1487 resp. alpha-plots in a single tab automatically
1488
1489
1490
1491 *** Version 0.9.5.1 (2006/05/05)
1492
1493 - general: Added a new option "zdiff" to the Makefile which runs
1494 "cvs diff" as "make diff" would do, but with compression
1495
1496 - general: accelerated MTFillMatrix (used for eample in all training
1497 and optimization macros) by skipping some obsolete calles in the
1498 eventloop the first and second loop could be accelerated by ~20%
1499
1500 - general: Added a missing feature in the MFilterList class which
1501 prevented MFEnergySlope from working correctly in trainenergy.C
1502
1503 - general: Accelerated the random forest training and usage a bit
1504
1505 - merpp: Adapted to new raw data file format version 6
1506
1507 - merpp: fixed a problem with reading the starguider reports
1508 after 6.3.2006
1509
1510 - callisto: At some times six pixels had to be exchanged manually in the
1511 data. If the pixels to be swaped are both not found, an error was raised
1512 and calibration was stopped. Now it is assumed they are intentially not
1513 mapped and the Error has been changed to a Warning.
1514
1515 - star: Added new image cleaning based on the arrival time of the shower.
1516 The new cleaning can be accessed using the parameter "Time" instead of
1517 the the old one (like "Absolute) in the star.rc-file.
1518 Recommended parameters:
1519 + MImgCleanStd.CleanLevel1: 8.2
1520 + MImgCleanStd.CleanLevel2: 5
1521 + MImgCleanStd.CleanRings: 2
1522 + MImgCleanStd.KeepSinglePixels: No
1523
1524 - star: Simplified the calculation of the effective on time. By letting
1525 the fit start in the third bin the result should become more stable.
1526 The fit quality is now ignored for the theta-plot which is not used
1527 in the analysis later. Still better pre-cut which, for example,
1528 remove events triggered by car-light (rate changing on a short
1529 time-scale) are missing.
1530
1531 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1532 for optimization (kWeakSource) which is suggested by the Berlin
1533 people for weak sources.
1534
1535 - macros: plotdb.C:
1536 + if no dataset and no time-interval is given only sequences with
1537 an effective on-time above five minutes are plotted anymore
1538 + added a new tab "RelTime" displaying the relative on-time
1539 (effective on-time divided by the observation time)
1540
1541 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1542 the optimization became a lot faster
1543
1544 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1545 To display them just delete the pads displayed on top.
1546
1547 - ganymed: fixed a bug which could cause strange behaviour in wobble
1548 mode if no starguider information was available due to an incorrect
1549 initialization of the starguider calibration
1550
1551 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1552 be changed from within the plot. It can also be setup from the
1553 resource file using:
1554 + MHDisp.fScaleMin: 0.325
1555 + MHDisp.fScaleMax: 0.475
1556
1557 - ganymed, showplot: Fixed a problem with the fit to the off-data
1558 (HistOff) which could cause a time lag or an inifinite loop.
1559 The bug did not effect the results at all.
1560
1561 - sponde: Added a new tab showing the effective collection area after
1562 trigger (including the software trigger)
1563
1564 - sponde: MMcSpectrumWeight has a new option which allows to define
1565 the scaling factor not by the integral of the events but at
1566 a defined energy:
1567 e.g. MMcSpectrumWeight.NormEnergy: 200
1568
1569 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1570 eventloops the loop could be accelerated by ~20%
1571
1572
1573
1574 *** Version 0.9.5 (2006/03/13)
1575
1576 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1577 and added the standard Disp-parametrization
1578
1579 - macros: added a new macro datacenter/macros/plotstat.C allowing
1580 to plot statistics about the data processing
1581
1582 - macros: added a new macro to plot the muon correction coefficients
1583 versus period (macros/plot/mucal.C)
1584
1585 - showplot: path inflation for ganymed files was broken
1586
1587 - callisto: Fixed an important bug. When the number of saturating pixels
1588 were calculated the bad pixel information already available from the
1589 calibration was ignored. This yields wrong values in case pixels
1590 are broken and saturate all the time or randomly.
1591
1592 - callisto: Updated Muon calibration constants. Spline data now also uses
1593 different values for different periods
1594
1595 - star: The time-evolution shown in the effective on-time plot now displays
1596 the axis range (if there are no holes it should be similar to the
1597 effective on-time)
1598
1599 - star: Added two new image parameters:
1600 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1601 the three pixels next to the center of gravity and the size
1602 + MNewImagePar.fConcCore: The ratio of the signals of all
1603 pixels inside or touching the ellipse and the size
1604
1605 - ganymed: now stops in requested source isn't found in catalog file
1606
1607 - ganymed: Many improvements to the phi-plot in wobble mode:
1608 + with a template the ideal background is displayed
1609 + a possible camera inhomogeneity is taken into account
1610 + the anti theta cut is better supported
1611 + the phi cut is automatically calculated from the theta cut
1612 See the examples in ganymed_wobble.rc for more details.
1613
1614 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1615 times the bin-width instead of the absolute energy
1616
1617 - ganymed: New cuts for on/off and wobble mode
1618
1619 - ganymed: The smearing of the False Source plot has been increased
1620 to 0.06
1621
1622 - ganymed: The starguider calibration can now be changed from the
1623 resource file.
1624 See the examples in ganymed*.rc for more details.
1625
1626 - ganymed: added a new option for on-/off-observations
1627 MJCut.RandomSourcePosition
1628 If switched on the distribution of observation time of the source
1629 position in the camera is calculated from the on-data and randomly
1630 applied with this distrbution to the off-data.
1631
1632 - ganymed: by skipping some obsolete calles in the eventloop the
1633 first and second loop could be accelerated by ~20%
1634
1635 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1636 position in the off-data randomly according to its distribution in the
1637 on-data.
1638
1639
1640
1641 *** Version 0.9.4.3 (2006/02/13)
1642
1643 - general: Fixed a bug in most of the programs which prevented the
1644 compile date in the startup message to be displayed
1645
1646 - general: Simplified program calls. The following abbreviations
1647 are now possible:
1648 showlog callisto 55599
1649 showplot signal 55599
1650 star 55599
1651 callisto 55999
1652 ganymed 2
1653 In this cases the corrsponding root-, log-, sequence- or dataset-
1654 filename is automatically compiled using the default datacenter
1655 paths ("/magic/*")
1656
1657 - general: Fixed a long outstanding bug which made axis tick marks
1658 disappear if MDataFormula was used (eg. abs(x))
1659
1660 - general: Updated MMath with new functions to calculate the results of
1661 a exponential, logarithmic and powerlaw fits analytically.
1662
1663 - general: Updated some macros with comments:
1664 + macros/optim/optimdisp.C
1665 + macros/optim/optimenergy.C
1666 + macros/optim/optimwobble.C:
1667
1668 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1669 files) now allows adding a pre-cut like in the optimization. E.g. this
1670 is useful to perform g/h-separation cuts before training the random
1671 forest.
1672
1673 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1674 correctly assigned in the raw data assignement table. A fix to correct
1675 the assignment tabel have been implemented.
1676
1677 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1678 by 90, 180 and 270 deg.
1679
1680 - general: the macro plotdb.C now allows to highlight sequences belonging
1681 to a datset. For more details see the descritions in the macro.
1682
1683 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1684 of the display, it gave wrong results espacially for big sizes.
1685 Now the embedded canvas should always have a ratio width/height=3/2.
1686 The "Size" options have been updated with values fitting the 3/2
1687 size ratio.
1688
1689 - RanForest:
1690 + Updated the random forest classes to support also the
1691 regression method implemented by Thomas H.
1692 + added new tutorial macro how to train the random forest
1693 for energy estimation (macros/optim/rfenergyest.C)
1694 + new classes to train the random forest (still in development)
1695 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1696 + new tutorial macros for random forest training in macros/train
1697 trainenergy.C, traindisp.C, trainseparation.C
1698
1699 - mars: now allows to setup a cut in the resource file mars.rc to choose
1700 the events to be displayed, eg:
1701 Cut.Condition: {0} && {1}
1702 Cut.0: MHillas.fSize>100
1703 Cut.1: MHillas.fSize<900
1704
1705 - merpp: Made aware of the new .rep format 200510250. This includes
1706 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1707 the discriminator thresholds (MCameraTD) and the disciminator
1708 delays (MCameraTD). All of them come with the CC report and are therefor
1709 written to the CC tree.
1710
1711 - callisto: fixed a bug in the calculation of the arrival times in
1712 the Digital Filter. They were all shifted by the same amount
1713 fHiGainFirst. This caused an offset in the order of the position of
1714 the left border of the extraction window in the times calculated
1715 from high-gain and from low-gain. The bug effected only the absolute
1716 arrival times. The bug was there since 30.1.2005.
1717
1718 - callisto: Changed the ExtractionWindow for the pulse position check
1719 such that the camera inhomogeneity becomes as less as possible and
1720 comparable to the pulso position check switched off. More details
1721 on the study will be given at our result web-page.
1722
1723 - ganymed: ganymed.rc, ganymed_onoff.rc:
1724 changed to new cuts trained with 1ES1218 and Crab-data
1725 for maximum sigma*log10(excess)
1726
1727 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1728 a new option was implemented to estimate Disp (CalcDisp)
1729
1730 - ganymed: Implemented two new options which allow
1731 to overwrite the default path to search for the sequence files
1732 --ins=/magic/sequences
1733 and where to search for the image data
1734 --ind=/magic/data/star
1735
1736 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1737 dx/dy from the resource file by
1738 MSrcPosCorrect.Dx
1739 MSrcPosCorrect.Dy
1740
1741 - ganymed: fixed reading the source catalog. Only as many chars
1742 as the requested source name had were compared (If a source
1743 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1744 were requested it could happen that the coordinates of
1745 "1ES1218" were read) The source coordinates are now printed
1746 in addition to its name to the logging output.
1747
1748 - ganymed: changed the background fit in the case of a ThetaSq function
1749 from a polynomial to a exponential, this should give a big improvement
1750 for on-only analysis'
1751
1752 - ganymed/sponde: Calculation of the error of single size-/energy-
1753 bins now uses Li/Ma (5) instead of LiMa (17)
1754
1755 - sponde: Added a plot E^2*dN/dE
1756
1757 - sponde: The energy estimator plot should now show values like
1758 they are commonly used.
1759
1760 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1761 (a powerlaw with cutoff didn't work before)
1762
1763
1764
1765 *** Version 0.9.4.2 (2005/10/01)
1766
1767 - general: added new tutorial macro macros/tutorials/threshold.C:
1768 how to calculate the threshold
1769
1770 - general: added a new game. Start it from the interpreter with
1771 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1772 and MagicReversi)
1773
1774 - general: neighbor pixels in MGeoms are now sorted clockwise
1775
1776 - merpp: made aware of new format 20050829-0
1777
1778 - callisto: New scale factors from muon analysis, stored in new
1779 resource file resources/calibration.rc
1780
1781 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1782 the eventloop if something went wrong. This is necessary for the
1783 automatic processing
1784
1785 - callisto: Implemented a new treatment for the time information
1786 developed by S.Ruegamer, this should give much better response than
1787 the old very primitive algorithm. This is especially important
1788 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1789 treatment was buggy! As neighbor pixels to interpolate the
1790 arrival times always the pixels 0 to 5 were taken)
1791
1792 - callisto: In addition to the new treatment of arrival times the
1793 decision of the treatment whether a pixel contains shower
1794 information or not is used to improve the signal interpolation
1795 further. Previously interpolated pixels showed a non-zero signal
1796 do the peak searching signal extractors. Having a signal pixel
1797 beside raised the signal above the cleaning level. Thus the
1798 pixel survived cleaning to often but with a too low mean signal.
1799 By replacing empty pixels with a gaus (mean and rms from the
1800 corresponding Area entries in MPedPhotCam) this effect can
1801 be supressed.
1802
1803 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1804 got lost when the events were stored by the calibration... fixed.
1805 (This was no problem for normal image cleaning because the pixel
1806 content was artificially set to 0 not surviving standard cleaning
1807 algorithm)
1808
1809 - callisto: Fixed a bug which caused the random and peak-search pedestal
1810 extracted with an extractor to be exchanged for the first (roughly)
1811 500 events (*Extractor and *ExtractorRndm).
1812 (They were simply exchanged in callisto.cc) This bug might have been
1813 introduced in Mars 0.9.4 when the order of calculation of the two
1814 types of pedestal in callisto got exchanged. The bug only effects
1815 the first seconds of data of each sequence.
1816
1817 - star: Taking the arrival time of Muons into account the calculation
1818 of the parameters could be made independant of the noise
1819 (pedestal rms). The dependance was due to the bias of the peak search
1820 extractor. Now only a ZA dependamcy is left which is not yet fully
1821 understood.
1822
1823 - ganymed: The sequences were still not sorted correctly in any case,
1824 because they were sorted by the full qualified path name. Now they
1825 are sorted by their sequence number.
1826
1827 - ganymed: new values for the spark-event-cut
1828
1829 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1830
1831
1832
1833 *** Version 0.9.4.1 (2005/08/18)
1834
1835 - callisto: fixed some problems with the calibration in case of
1836 inteleaved events. Therefor the final and some intermediate
1837 fits are skipped which would take place on partly filled #
1838 histograms and gave wrong results or failed completely.
1839
1840 - callisto: If the intermediate finalization of the histograms
1841 calculating the mean charge of the calibration signal fails
1842 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1843
1844 - ganymed: Fixed some bugs which caused problems in On-only mode.
1845 Still the false source plot doesn't give reasonable results.
1846
1847
1848
1849 *** Version 0.9.4 (2005/08/05)
1850
1851 - general: Fixed the ZA binning. It did not correctly fit the
1852 MC binning
1853
1854 - general: Added a class to correct for the missfocussing in
1855 April (MSrcPosCorrect)
1856
1857 - general: Random Forest energy estimator should now work properly
1858
1859 - general: MHCamera now displays the profiles in deg instead of mm
1860
1861 - general: MH::SetPalette offers a lot of new palettes
1862
1863 - general: MHillas - the case of CorrXY==0 is now handled properly
1864
1865 - general: implemented the possibility to change the line and
1866 marker style of a sky-grid drawn by MAstroCatalog
1867
1868 - general: Runs in sequences and datasets are now automatically
1869 ordered (it is assumed that the order of their filenames correctly
1870 represents the order of observations) to ensure correct reading
1871 of the subsystem data
1872
1873 - general: Runs cannot be added to a sequence twice anymore. Also
1874 Sequences cannot be added twice anymore to a dataset.
1875
1876 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1877 It gave wrong results by 1./2pi
1878
1879 - showplot: got a new option to start a root interpreter, too
1880
1881 - mars: now displays a rough estimate of Disp and the third moment
1882
1883 - mars: now displays the event time MTime if available
1884
1885 - mars: show muon parameters graphically
1886
1887 - mars: now the file to open can be given as commandline
1888 argument
1889
1890 - merpp: Added support for new arehucas version >= 200507190
1891 implementing values for three temperature sensors in the
1892 counting house (MCameraAUX) and the name of the HV settings file
1893 (MCameraHV).
1894
1895 - merrp: Also fixed some problems with wrong versions numbers stated
1896 by arehucas and implemented some fixed for old versions (<200407070)
1897
1898 - callisto: MCalibrationHiLoCam can now be printed from its context
1899 menu, eg in the TBrowser
1900
1901 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1902 - 1.39 (MExtractTimeAndChargeSpline)
1903 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1904 This is important mainly for timing studies.
1905
1906 - callisto: Changed limits in MHCalibrationChargeCalc from
1907 - -100.125 to -98 (fgChargeHiGainFirst)
1908 - 1899.875 to 1902. (fgChargeHiGainLast)
1909 - -100.25 to -99 (fgChargeLoGainFirst)
1910 - 899.75 to 901. (fgChargeLoGainLast)
1911 Introduced new limits:
1912 - fgNumLoGainBlackoutLimit: 0.05
1913 - fgLoGainBlackoutLimit: 3.5
1914 - fgLoGainPickupLimit: 3.5
1915
1916 - callisto: The handling of automatic weights for the digital filter
1917 has been improved. There are now new calibration weights special
1918 for Monte Carlo calibrations.
1919
1920 - callisto: Updated Muon scale with latest results (1% difference
1921 for most data, 5% for Mar/Apr'05)
1922
1923 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1924 was saturated and the blackout-events in the low-gain exceed the
1925 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1926 This excludes those pixels which have a saturating high-gain
1927 channel, but the low-gain switch does not switch often enough
1928 to make the distribution reliable.
1929
1930 - callisto: fix a bug counting the number of saturated events. Up to now,
1931 the number of saturated slices was counted (which is one for a not too
1932 high number), but for some (pathological) pixels, many more slices
1933 saturated and produced wrong limits.
1934
1935 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1936 + MCalibrationRelTimeCam.CheckFitResults: Yes
1937 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1938 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1939 + MCalibrationRelTimeCam.CheckOscillations: Yes
1940
1941 - callisto: introduce max. number of events for intercalibration,
1942 the rest gets skipped. Default: 4096
1943 The calibration causes too many un-reliable pixels if more
1944 than about 5000 events are treated (@500 Hz) because of the
1945 mode hopping of the VCSels. However, in the past, some
1946 calibration runs have been taken (erroneously) with more
1947 than 5000 events, especially the intensity scans where
1948 a good precision is needed.
1949
1950 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1951 photo-electrons for the spline extractor by 1-2% (correctly).
1952
1953 - callisto: The intercalibration is now done using a full f-factor
1954 method instead of a simple update. This makes things slower but
1955 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1956 changes.
1957
1958 - callisto: MPedestalY3 now uses the same extraction range as the data
1959 as calculated by MPedestalY2
1960
1961 - callisto: A check of the fraction of allowed unsuitable (10%) and
1962 unreliable (30%) pixels has been addded when the conversion is
1963 calculated from interleaved events
1964
1965 - star: fixed a bug which caused MEffectiveOnTime containers not to
1966 be written. In the worst case they were skipped almost all, in the
1967 best case they were all ok. It depends on how often the new value
1968 was assigned just with an event which was skipped later by another
1969 task
1970
1971 - star: new histograms MHPointing and MHRate
1972
1973 - star: New tab (Currents) displaying the time evolution of the mean
1974 DC currents
1975
1976 - star: New tab (MeanRms) displaying the time volution of the mean
1977 Pedestal Rms
1978
1979 - star: Output now contains MReportStarguider
1980
1981 - star: Improved muon analysis. Due to the absense of a constant
1982 for the gaus fit for arc width and the fact that the arcwidth
1983 plot was a histogram instead of a profile the resulting psf
1984 became pedestal rms dependant
1985
1986 - ganymed: added new plot (MHPhi) for wobble mode as described in
1987 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1988
1989 - ganymed: corrects now (correctly?) for the misspointing in
1990 May/April 05
1991
1992 - ganymed: Two new default templates for ganymed.rc are avilable:
1993 ganymed_onoff.rc and ganymed_wobble.rc
1994
1995 - ganymed: The first version of MFMagicCuts has been released
1996
1997 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1998
1999 - ganymed, sponde: There are two new options to determin the number
2000 of bins for the signal region (NumBinsSignal) and the number of
2001 total bins (NumBinsTotal) in the MHThetaSq histogram
2002
2003 - ganymed: optimized palettes for MHDisp
2004
2005 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2006 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2007 sqrt(2) to large
2008
2009 - ganymed: The false source plot (MHDisp) is now based on Disp
2010 and a background model determined in the first loop is
2011 subtracted
2012
2013 - ganymed: MFMagicCuts are now available in the cvs. The correct
2014 solution for the disp ambiguity problem is now calculated using
2015 the third moment. The third moment cut therefor is skipped.
2016
2017 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2018 already determined by the third moment along the major axis and
2019 so its actual sign is aligned along the major axis of the shower.
2020
2021 - ganymed: If starguider data is available it is taken into account
2022 when calculating the source position. This is especially important
2023 for wobble data at high zenith angles and culmination data.
2024
2025 - ganymed: If available the starguider data is taken into account as
2026 good as it is possible without a starguider calibration. To switch
2027 it off add
2028 MPointingDevCalc.MaxAbsDev: -1
2029 to your ganymed.rc
2030
2031 - sponde: the zenith angle distribution is now weighted instead of
2032 choosen by default. This gurantees higher statistics in the highest
2033 and lowest energy bins. To switch this behaviour off use...
2034
2035 - sponde: now automatically displays the energy threshold
2036
2037
2038
2039 *** Version 0.9.3 (2005/06/03)
2040
2041 - general: MMcEvt now derived from MMcEvtBasic which should
2042 have no influence on compatibility with older camera files
2043
2044 - general: Implemented a new option to MReadReports which allows
2045 to force reading of the first event of some trees (eg. Drive-tree)
2046 before any other tree.
2047
2048 - general: Made a fix to MPointingPosCalc which assumes that the
2049 run-type is real-data if Process is called before ReInit, such
2050 that also the very first Drive-events in a run are treated
2051 correctly.
2052
2053 - shoplot now displays the filename in the title bar of the window
2054
2055 - merpp: new options: --auto-time-start --auto-time-stop which
2056 allow to cut updating with slow-control at the start- or
2057 (previousle --auto-time only allowed: and) stop-time of
2058 the run stored in the runheader.
2059
2060 - callisto: changed default of fgFallTimeHiGain in
2061 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2062 already set as default in callisto_Dec04Jan05.rc
2063
2064 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2065 now changes the filename for new weights automatically for
2066 cosmics, MC and for different calibration colors.
2067
2068 - callisto: a problem with the order of some code cause the
2069 name of the weights file in MPedestalY2 to be ignored.
2070 Wrongly the calibration_UV weights were used instead
2071 of the cosmics weights set in callisto.rc.
2072
2073 - callisto: should allow ct1 pulser data when the color is
2074 explicitly set also for pretty new runs
2075
2076 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2077 to introduce an additional scale factor (should be around 1)
2078 to adapt for slight deviations in different extractors from
2079 the MC calibration. For MC calibrations the scale factor
2080 is fixed to 1
2081
2082 - callisto: MFCosmics should handle very high signals a bit
2083 more accurate now
2084
2085 - callisto: when calculating the mean pedestal rms for different
2086 pixel sizes or sectors also kUnsuitableEvt is now taken into
2087 account - not only kUnsuitableRun
2088
2089 - callisto: '-raw' option is now the default
2090
2091 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2092 This has the advantage that mean values in the calibration (eg
2093 arrival times) are calculated more accuratly.
2094
2095 - callisto: In the resource file callisto_Dec04Jan05.rc
2096 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2097
2098 - callisto: new Hi-/Lo-Gain intercalibration constants
2099 hilocalib_sp1.root and hilocalib_sp1_mc.root
2100
2101 - callisto: changed default for MJPedestalY2.MaxEvents
2102 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2103
2104 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2105 has changed from 9.0 to 6.0. This is necessary to exclude two very
2106 ringing pixels in September which - when kept - destroy the image
2107 cleaning around them (Markus G.)
2108
2109 - callisto: (!) The Muon analysis of all data taken so far has
2110 suggested that different extractors give slightly different
2111 absolute results after calibration, due to there different
2112 handling of the calibration- and cosmics pulse shape. Although
2113 the over all calibration seems to be a bit to pesimistic (or
2114 the MC seems to be a little bit - 3-5% - too much attenuated).
2115 There for correction factors have been introduced which correct
2116 the calibration constants by
2117 0.956937799 for Digital Filter (callisto.rc)
2118 and
2119 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2120 calibration. The main advantage is, that both data types can
2121 be easily analysed together and compared to the same MC sample.
2122 The factors are choosen such, that the reference is now a
2123 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2124
2125 - star: fixed a bug which caused the first bin of the histograms
2126 vs time to disapear in PostProcess. This gave wrong results
2127 on the screen. The output and all following programs not
2128 directly accessing the histograms haven't been affected
2129
2130 - star, ganymed: Made sure that always the first Drive-tree event
2131 is read and Processed before the first data event was read.
2132
2133 - ganymed: implemented the possibility to replace the standard
2134 false source plot with a different one. For example: If
2135 you want to use a Disp based FS plot use the resource:
2136 NameHistFS: MHDisp
2137 For details about the requirements of these plots look
2138 at the corresponding classes
2139
2140 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2141 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2142 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2143 case MAlphaFitter is setup correctly. For On-Only optimization
2144 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2145 RunOn() instead of Run(). For energy estimation MJOptimize
2146 has been replaced by MJOptimizeEnergy
2147
2148 - sponde: The input MC spectrum can now be weighted to fake a
2149 different spectrum. This is done via MMcSpectrumWeight. For
2150 more details see the class description and sponde.rc
2151
2152 - sponde: The paremeter comparsion plots are not scaled by
2153 their entries anymore. Instead the MC plot is scaled by using
2154 the result spectrum of the analysis. If the input MC spectrum
2155 and the result spectrum has different slopes the absolut
2156 normalization is normally wrong.
2157
2158
2159
2160 *** Version 0.9.2 (2005/05/20)
2161
2162 - general: Changed the default paths for calibrated data and image
2163 files. (The implemented access to these files doesn't yet exist)
2164
2165 - general: support for MRunIter has been removed from the job classes
2166 (use the setter functions of MSeqeunce instead)
2167
2168 - general: ProcessFile has been renamed to Process in all job classes,
2169 because ProcessFile is missleading
2170
2171 - general: The storage of the palette in MHCamera is now possible
2172
2173 - general: new bits describing unsuitable and unreliable pixels have
2174 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2175 kDeadPedestalRms, kFluctuatingArrivalTimes
2176
2177 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2178 versions newer than V200404070
2179
2180 - general: support for cc file versions newer than V200504130. Added
2181 support for active loads (MCameraActiveLoad) and central pixel
2182 (MCameraCentralPixel)
2183
2184 - general: added new histograms for image parameters versus size
2185 (MHVsSize)
2186
2187 - general: The eventloop now automatically calls PrintStatistics
2188
2189 - Status Display: Improved support for printing:
2190 + A default can now be set in .rootrc (for more details see
2191 MStatusDisplay::PrintPS)
2192 + A print dialog is opened so that printer and command line
2193 can be canged
2194
2195 - showlog: improved such that it handles different verbosity levels
2196 more accurate now. This mean you can suppress output when
2197 using showlog.
2198
2199 - showplot: improved
2200 + The new graphics formats have been implemented
2201 (pdf, svg, png, jpg and xpm)
2202 + Implemented an interface for printing. Because you can change
2203 the printing command from the command line you can use all
2204 the nice postscript tool. To print a booklet for example call:
2205 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2206 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2207 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2208
2209 - callisto: fixed a bug in the recognition of the calibration bit
2210 pattern. Concerns only intensity calibration. (The strength of the
2211 intensity has been updated in some cases)
2212
2213 - callisto: add a filter against PIN Diode events when running over
2214 calibration runs since some of the recent calibration runs have
2215 been taken with Pin Diode.
2216
2217 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2218 39943, 44833 in the calibration (MCalibColorSet)
2219
2220 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2221 been set to 1e-18 in callisto_Dec04_Jan05.rc
2222
2223 - callisto: in callisto_Dec04Jan05.rc: set value for
2224 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2225 statistics for the calculation of the mean pulse time
2226 of the cosmisc
2227
2228 - callisto: the charge limit in the calibration has been raised
2229 from 2.5 to 4.5
2230
2231 - callisto: new setup read from callisto.rc
2232 + MCalibCalcFromPast.fNumEventsDump
2233 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2234 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2235
2236 - callisto: MExtractTimeAndChargeSpline extractor:
2237 + The integration ranges were shifted by 0.2 FADC slices to the right.
2238 + unreliable handling of floating point values caused different
2239 results on different platform or with different compiler options:
2240 The new algorithm is numerically exact and more accurate because
2241 it doesn't calculate the integration position by multiple times
2242 adding the step-size (which results in numerical uncertanties
2243 exspecially if multiplied with large numbers)
2244 + A lot of fixes have been introduced which effects integrating the
2245 spline at the edges of the valid range. In this case any memory
2246 was randomly accessed. This behaviour can be tested replacing
2247 all MArrayF by TArrayF which perform a range check (but of course
2248 they are a lot slower)
2249 ! No result obtained with the Spline before can be trusted! Due to
2250 random memory access it might by completely random!
2251
2252 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2253 + extraction range in the high gain to 4.
2254 + weights file to cosmics_weights46.dat
2255
2256 - callisto:
2257 + introduce the check for fluctuating arrival times.
2258 + set charge limit to from 2.5 to 4.5
2259 + introduce asymmetric exclusion due to "deviating number of phes":
2260 Default: -9.0 +4.5
2261 + make deviating number of phes unsuitable (see David's findings).
2262
2263 - callisto: fixed the display of unsuitable pixels. The old change
2264 to a real profile in MHCamera broke it.
2265
2266 - callisto: The cosmics filter is used in MJCalibration now
2267 independant of the pulser color (formaly it was used only for
2268 CT1-pulser data). The threshold of number of max empty pixels
2269 has been raised from 2% to 5% in MJCalibration. The maximum
2270 fraction of rejected event is 50% otherwise the calibration has
2271 failed. The filter now ignores unsuitable pixels.
2272 Setup the filter from callisto.rc using "ContCosmics"
2273 (see MFCosmics::ReadEnv)
2274
2275 - callisto: changed default for fgOffsetFromLogain back
2276 from -2.8 to -1.8 in digital filter.
2277
2278 - callisto: for the common extractors
2279 + MExtractFixedWindow
2280 * MExtractTimeAndChargeSlidingWindow
2281 * MExtractTimeAndChargeSpline
2282 * MExtractTimeAndChargeDigitalFilter
2283 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2284 and fResolutionPerPheLoGain
2285
2286 - callisto: Updated the hi-/lo-gain intercalibration constants
2287 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2288 hilocalib_df6.root
2289
2290 - callisto: The default lo-gain extraction window for the
2291 MExtractTimeAndChargeSlidingWindow extractor has been increased
2292 from 6 to 8 to take the stretch of the pusle into account
2293
2294 - callisto (!!!): fixed an important bug in the setting of the
2295 incoming pedestal pointer to the signal extractor extracting
2296 pedestals. This bug caused the pedestals not to be subtracted
2297 correctly in the calibration afterwards. The effect was about 10%
2298 too high conversion factors for the digital filter and the spline
2299 and more than 40% for the sliding window.
2300 The bug existed since end of February! (Markus G.)
2301
2302 - star: added muon support to star. A new tab "MHMuonPar" is
2303 displayed. The lower right plot is an estimate of the point spread
2304 function. A reference value is displayed. To get the real PSF
2305 you must compare with MC. The setup for the muon analysis
2306 is done in star.rc. More informations can be found in
2307 MHSingleMuon and MHCalibParCalc
2308
2309 - star: The weather data is now displayed in star
2310
2311 - star: MEventRateCalc handles the calculation of the event rate more
2312 accurate now in case of the start of a new run inside a sequence
2313
2314 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2315 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2316 changed only minimally
2317
2318 - ganymed: (MJCut and MJOptimize) now displayes the number of
2319 excess events versus size. The energy estimation is done in
2320 MJSpectrum (sponde)
2321
2322 - ganymed: got support for using other variables than Alpha, eg. Theta.
2323 Therefor you need a class deriving from MHAlpha which supports
2324 this variable (one is already existing: MHTheta, which is now the
2325 default in ganymed). It is setup through ganymed.rc
2326
2327 - added a full featured spectrum program (sponde) which reads
2328 ganymed output and monte carlos and compiles a spectrum
2329
2330
2331
2332 *** Version 0.9.1 (2005/04/14)
2333
2334 - Fix bug on the arrival time reconstruction when using Digital
2335 Filter (in some marginal cases (10%) times were reconstructed shifted
2336 by 0.2 slices)
2337
2338 - all executables now return 2 where in previous versions -1 has
2339 been returned (gave problems with shell-scripts)
2340
2341 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2342 also done with a intercalibration input file
2343
2344 - a bug in the time fine adjustment of the digital filter has been fixed
2345
2346 - a lot of small fixes to calling TPad::Divide with a margin==0
2347
2348 - MStatusDisplay now shows the memory usage
2349
2350 - added a memory leak statistic after the eventloop
2351
2352 - MHadronness replaced by MParameterD
2353
2354 - MEnergyEst replaced by MParameterD
2355
2356 - wobble mode can now be switched on from the data-set
2357
2358 - switched on bad pixel detection for a pedestal level
2359 which is more than 5 times the variance
2360
2361 - Fixed default paths to be correct for the new data center
2362
2363 - Fixed handling of drive data. The pointing position in now
2364 copied to MPointingPos inside star for real and MC events
2365
2366 - made sure, that the sequences in a dataset are sorted by
2367 their number to ensure the correct synchronization
2368
2369 - added all resource files necessary to handle spline extraction
2370 of signal for the late 2004 and the early 2005 data
2371
2372 - update the reference lines for the december data
2373
2374 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2375 This is important for the Dec. and Jan. data where the calibration
2376 pulse position changes much.
2377
2378 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2379 filter. This corrects only an defective extraction of the MC at
2380 low-gain signals lower than 90 phes.
2381
2382 - fixed some slowdown in calibrating data with interleaved events from
2383 Jan and Dec. As a workaround made the pretty palette the default.
2384 The inverse Deep Blue Sea has a bug which slows down long calibration
2385 runs a lot.
2386
2387 - implemented new values from new starguider report as defined
2388 in TDAS00-07 V7.1 (eg SkyBrighness)
2389
2390 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2391 in starguider report (If you merpp the same reports with this version
2392 you'll get the correct units (arcmin) but a different result
2393 than with old versions (wrong units))
2394
2395 - Now the status display can also write PNG, JPEG and XPM (other file
2396 formats are still unsupported by root)
2397
2398 - added a lot of scripts and macros in directory datacenter used
2399 for automatic processing
2400
2401
2402
2403 *** Version 0.9 (2005/03/23)
2404
2405 - Calibration is now done autmatically into photo-electrons like
2406 decided by the Collaboration Board
2407
2408 - Reference lines in the display can be read from resource file
2409
2410 - Interlaced calibration events can be handled by callisto
2411
2412 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2413 and applied in callisto.
2414
2415 - class MJCalibTest can be called by callisto
2416
2417 - callisto can now run with three data types: rawdata, rootdata, MC
2418
2419 - added two classes mreport/MReportStarguider.cc and
2420 mreport/MReportStarguider.h for implementing starguider-data
2421
2422 - the output of merpp-update now contains starguider information:
2423 MReportStarguider and MTimeStarguider
2424
2425 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2426 values were lower than they should. This was more visible for high
2427 energy (Size) events.
2428
2429 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2430
2431 - added a new loop to callisto to support the correct extraction of
2432 the pedestal and pedestal rms through the signal extractor
2433
2434 - added class to perform fourier tranformation of a hexagonal structure
2435 (MHexagonalFT)
2436
2437 - added class to perform fourier tranformation of a hexagonal structure
2438 in a tasklist (MHexagonalFTCalc) example: hft.C
2439
2440 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2441 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2442 small pixels, example: extendcam.C
2443
2444 - added possibility to write data to memory (TTree) using MWriteRootFile
2445
2446 - added possibility to read a TTree stored only in memory by MReadTree
2447
2448 - new classes to deal with the interleaved calibration events:
2449 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2450
2451 - implemented filters to callisto to skip calibration events
2452
2453 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2454 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2455 the slices by statistics
2456 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2457 signal extractor without randomization
2458 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2459 with the signal extractor with randomization (extraction window is
2460 randomly fixed)
2461 The three kind of pedestal is not yet implemented (for speed reasons) as
2462 long as nobody really needs it:
2463 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2464 extracted with the signal extractor with randomization
2465
2466 - callisto now finds the pulse position in the data automatically
2467
2468 - implemented data reduction in calibrated data by reducing the precision
2469 of the stored floating point values (pedestal, rms and signal) to
2470 roughly 0.5%
2471
2472 - fixed showplot to make file format conversion (eg. converting a
2473 status display stored in a root file into a postscript file) in
2474 batch mode possible:
2475 showplot -b --save-as-ps[=outfile.ps] infile.root
2476
2477 - Allow class names as part of filter rules, eg
2478 (MFSupercuts) && (MHillas.fSize>100)
2479
2480 - fixed a lot of stuff to allow all programs to process MonteCarlo
2481 camera files.
2482
2483 - enhanced possibility to debug reading of resource file
2484
2485 - MDataChain should handle priorities of operator more
2486 accurate now
2487
2488 - completely revised the container in which the signal is stored
2489 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2490 * the new implementation is faster and
2491 * needs less storage space
2492
2493 - FIRST version which can process Monte Carlos through the
2494 whole chain of programs (callisto, star, etc)
2495
2496 - implemented new image parameters for the border length of
2497 the shower image (MNewImagePar2)
2498
2499 - implemented wobble-mode in ganymed
2500
2501 - new class (MJOptimize) taking care of all optimization processes
2502
2503
2504
2505 *** Version 0.8.6 (2004/10/05)
2506
2507 - New combined signal and time extractor
2508 MExtractTimeAndChargeDigitalFilter
2509
2510 - The Report for the trigger section in the CC run summary has been
2511 updated, and now the IPRs (Individual Pixel Rates) are available.
2512
2513 - new macros for database interaction: filldotrun.C, filldotrbk.C
2514
2515 - added new program which can convert colored output which was redirected
2516 into a file back into colored text (for example to display it with
2517 more): showlog
2518
2519 - added new program to display an MStatusArray of plots (stored with
2520 MStatusDisplay) from a file: showplot
2521
2522 - Added support for Sequences (MSequence). Sequences are blocks of run
2523 files containing the same calibration and belonging to the same
2524 source
2525
2526 - Added a new task (MTaskEnv) which can be used in setup files to switch
2527 between different tasks (for example to choose a signal extractor)
2528
2529 - Implemented automatic file splitting in MWriteRootFile
2530
2531 - After image cleaning an island index is assigned to all used pixels.
2532 The index corresponds to the order of the islands in size.
2533
2534 - added a cleaning which takes signal height _and_ arrival time into
2535 account: probability cleaning (for more details see MImgCleanStd)
2536
2537 - added a cleaning which takes takes the absolute number of photons
2538 times the area ratio as cleaning level
2539 (for more details see MImgCleanStd)
2540
2541 - Changed calculation of image parameters such, that it can be done
2542 for all used pixels or the pixels with a defined island index only
2543
2544 - implemented new image parameters displaying the number of islands,
2545 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2546
2547 - event display in executable changed to support also calibrated files
2548 (done with MJCalibrateSignal)
2549
2550 - added program doing the calibration and the signal extraction
2551 and signal calibration: callisto Most part of the setup is done
2552 by a resource file: callisto.rc
2553
2554 - implemented support for pixels with negative IDs (Raw file format
2555 version 4)
2556
2557 - implemented an new option in merpp (--auto-time) to get the time
2558 range for cc and/or caco data from the run header of the raw data
2559
2560 - New star-program (star and MJStar). Taking calibrated data from
2561 callisto/MJCalibrateSignal as input. The setup is done through
2562 a resource file: star.rc
2563
2564 - Added possibility to setup the eventloop in the mars-executable
2565 Camera Display by a resource file: mars.rc
2566
2567 - The the mars-executable Camera Display can now also read
2568 calibrated data files written by callisto/MJCalibrateSignal
2569
2570 - Added a new class which can calculate the source position in
2571 the camera from a pointing model known to be correct and
2572 the pointing model used for observations (MSrcPosFromModel)
2573
2574 - added a new version of the class calculating the effective on-time
2575 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2576 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2577 MHTimeDiffTheta.
2578
2579 - added the possibility to count how often a signal is above (or
2580 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2581 can replace MHTriggerLvl0)
2582
2583 - added ore convinient ways to set the axis-titles of your histograms
2584 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2585 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2586
2587
2588
2589 *** Version 0.8.5 (2004/08/06)
2590
2591 - new Signal Extractors: MExtractFixedWindowSpline
2592 and MExtractAmplitudeSpline
2593
2594 - implementes interleave in merpp to be able to merpp parts of a file
2595
2596 - implemented force-functionality to merpp
2597
2598 - star display to display star catalogs (MAstroCatalog)
2599
2600 - star display to 'mirror' stars to the camera (MAstroCamera)
2601
2602 - implemented a new cleaning option which allows cleaning scaled with
2603 the real ratio of the rms depending on the pixel size, not only the
2604 square root of the pixelsize (MImgCleanStd, MCameraData)
2605
2606 - removed obsolete MBlind* classes
2607
2608 - Signal extractor taking the AB flag into account implemented (this makes
2609 an odd number of slices for signal extraction possible
2610 (MExtractSignalABcorr)
2611
2612 - implemented a class extracting the pedestal from the raw-data (events)
2613 itself using empty lo-gain (MpedCalcFromLoGain)
2614
2615 - Added mean values to MPedPhotCam
2616
2617 - Added Makefile for Darwin (this OS is NOT officially supported!)
2618
2619
2620
2621 *** Version 0.8.4 (2004/04/19)
2622
2623 - new fast arrival time extractor using cubic splines:
2624 MExtractTimeFastSpline
2625
2626 - implementes multi-argument support in MDataChain
2627 ("pow(a, b)")
2628
2629 - implemented double reference support in MDataChain
2630 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2631
2632 - added support in MF for expressiond like
2633 "MHillas.fWidth<2*<MHillas.fLength"
2634
2635 - MDataChain is now able to support variables like [0], [1], ...
2636 which can be used in fit functions as parameters. The interface
2637 is implemented through the new virtual function
2638 MParContainer::SetVariables
2639
2640 - added new class MArrivalTimeCam/MArrivalTimePix:
2641 Storage containers to hold the ArrivalTime of the camera/pixel
2642
2643 - added new classes for the calibration of relative arrival times:
2644 MCalibrationRelTimePix and MCalibrationRelTimeCam
2645
2646 - added new classes to extract the signal of the blind pixel and the
2647 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2648
2649 - added new classes for the bad-pixels treatment (MBadPixels*)
2650 which are more powerfull than the old ones (MBlindPixel*)
2651 and will replace them.
2652
2653 - added filter against cosmics: MFCosmics
2654
2655 - added new class MArrivalTimeCalc2:
2656 Calculates the arrival time as the signal weighted mean of the time
2657 slices in the maximum window
2658
2659 - added a new macro call pointspreadfucntion.C that fits with a 2D
2660 gaussian the DC spot for an star. It gives you the RMS of
2661 the PSF and the center of the star, very useful for misspointing
2662 studies.
2663
2664 - added support for multi-telescope camera files. Added classes
2665 MStereoCalc and MStereoPar, classes to calculate and store shower
2666 parameters calculated from the data of two telescopes, for the MC
2667 studies regarding the MAGIC clone.
2668
2669 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2670 MC data calibrated in photons instead of ADC counts.
2671
2672 - added three macros to show the calibration and analysis chain of
2673 MC data. The macro starmc.C does both calibration and analysis, producing
2674 an output containing Hillas parameters for each event. The macro
2675 mccalibrate.C does just the calibration and writes out a file containing
2676 pixel information in photons instead of FADC data. The macro starmc2.C
2677 reads in such a file and produces an output with Hillas parameters.
2678
2679 - added MPedPhotCalc to compute pedestals in units of photons, see
2680 macro pedphotcalc.C
2681
2682 - added all class to perform the calibration, see macro calibration.C
2683
2684 - added class MFFT to perform Fast Fourier Transforms
2685
2686 - added class MSimulatedAnnealing to perform simulated annealing
2687 minimizations
2688
2689 - added new macro bootcampstandardanalysis.C which holds the skeleton
2690 of the analysis chain discussed in the december bootcamp.
2691
2692 - added support for DAQ raw data file format V2
2693
2694 - implemented an arbitrary time stamp for the events from raw-data
2695 files with file version<3. It is calculated from the run number,
2696 the date of start and the FADC clock tick from the first module
2697
2698 - implemented the correct decoding of the event time-stamp
2699 coming from the DAQ for raw-data files with file-version>2
2700
2701 - added a new classes storing the pedestals in units of photons:
2702 MPedPhotPix, MPedPhotCam
2703
2704 - added support for DC current files from the camera control
2705
2706 - added support for start- and stop-time when merpping report files
2707
2708 - added MReportCC storing the weather data from the CC-REPORT
2709
2710 - added class to fill trainings and test matrices (MTFillMatrix)
2711
2712 - added a filter performing a software trigger (MFSoftwareTrigger)
2713
2714 - Added classes to perform parts of the standard analysis (Jobs):
2715 + MJPedestals
2716 + MJCalibration
2717 + MJExtractSignal
2718 Note: All of them are preliminary!
2719
2720 - Added Iterator to iterate over files giving only the run-number
2721
2722 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2723 the evolution of a sector vs time
2724
2725
2726
2727 *** Version 0.8.3 (2003/12/05)
2728
2729 - adapted Random Forest classes to allow the use with MC
2730 multi-telescope files which can be produced with the coming
2731 camera version 0.7.
2732
2733 - added classes to read and interprete central control report files
2734 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2735
2736 - enhanced merpp (the executable) to support .raw and .rep files.
2737
2738 - added classes for light calibration (MCalibration* and
2739 MHCalibration*) by Markus Gaug. Further work has to be and will
2740 be done soon.
2741
2742 - Added a preliminary 'synchronizer' (MReadReports) which will
2743 replace MReadMarsFile as soon as it is finished.
2744
2745 - Added a tutorial macro demonstrating how report files are merpped
2746 and how they can be read from the root file in the correct order
2747 of time (readrep.C)
2748
2749 - Added a generalized histogram (similar to MH3) called MVsTime
2750 which allows to plot variables (or rules - MDataChain - of
2751 variables) vs time. For an example have a look at tempvstime.C.
2752
2753 - Changed the name of the event trees:
2754 + Events --> Events
2755 + PedEvents --> Pedestals
2756 + CalEvents --> Calibration
2757
2758 - changed name of MTime in the event trees from MRawEvtTime to MTime
2759
2760 - added displaying the sector indices to the mars event display
2761
2762 - Magic Online Analysis (MOnA) implemented in a first version
2763 (see mona.cc, MOnlineDump and MOnlineDisplay)
2764
2765 - added classes to calculate event rate
2766 (preliminary: MEventRateCalc, MEventRate)
2767
2768 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2769
2770 - added classes dealing with the telescope pointing position (MPointing*)
2771
2772 - implemented the 'final' Mars time stamp based on some experiences with
2773 the new 'Synchonizer'
2774
2775
2776
2777 *** Version 0.8.2 (2003/11/10)
2778
2779 - accelerated standard analysis by a factor of 6-8 ...
2780 + doing precalculations in MGeomCam for the pixel area ratio
2781 + creating a look up table for the single pixels in MCerPhotEvt
2782
2783 - added task to calculates weights in case you want to 'change'
2784 the energy spectrum of a monte carlo file
2785 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2786
2787 - added a new executable star which implements the
2788 star.C macro as precompiled executable. Currently a flexible
2789 setup is not possible, but a 'input card' setup will follow.
2790
2791 - Starting to implement Multi-Telescope-Support based on the
2792 upcomming camera version 0.7. The base for a general support
2793 is implemented and the star-functionality is proven to work.
2794
2795 - Replaced Event-Display in and Camera-Display in the Mars GUI
2796 executable by a more convinient display base on MStatusDisplay.
2797
2798 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2799
2800
2801
2802 *** Version 0.8.1 (2003/10/20)
2803
2804 - added signal subtraction for pure on data by means of fitting
2805 the background in the off region or by performing a combined
2806 signal/background fit. Provides necessary histograms for
2807 obtaining energy spectra and a light curve.
2808
2809 - added classes to perform and study the selection of the
2810 2nd Level Trigger on MC data (example in triglvl2.C macro)
2811
2812 - added pedestal calculation
2813
2814 - implemented "democratic cleaning" (tail cut value proportional
2815 to pixel area) according to Wolfgang's suggestion.
2816
2817 - added Sigmabar treatment (calculation and basic histogramming)
2818
2819 - added basic routines to apply padding
2820
2821 - added first implementation of MARS-based source visibility plotter
2822 (needs to be linked against slalib, preliminary version)
2823
2824 - enhanced functionality of data chains: random numbers, conversion
2825 functions and access to MHMatrix objects
2826
2827 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2828 numbers under certain circumstances (runs with 0 events included)
2829
2830 - fixed a bug in the general filter MF (didn't work on some systems
2831 at all)
2832
2833 - fixed a bug in chaining files, which caused the analysis to crash or
2834 ignore files
2835
2836 - implemented more geometry classes describing the parameters used
2837 to simulate the PMT camera
2838
2839 - added new Monte Carlo classes containing the setup of the different
2840 programs in the MC chain.
2841
2842 - added a (preliminary) general task to evaluate chi-square of a given
2843 parameter in an eventloop.
2844
2845 - first implementation of a container describing the observatory
2846 location (Long, Lat, etc)
2847
2848 - added Random Forest - method for g/h-separation
2849
2850 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2851 (this means, that it is compiling, but not yet fully tested)
2852
2853 - added a new status display which can show the present status
2854 of histograms while an eventloop is running (MStatusDisplay,
2855 an example can be found at status.C)
2856
2857 - reorganized directories:
2858 classes describing the image --> mimage
2859 classes containing Monte Carlo Histograms --> mhistmc
2860 classes for Random Forest method --> mranforest
2861
2862 - added (event-)weights to fill histograms
2863
2864 - colors in logging output to screen
2865
2866 - changes to the Image Parameter declaration:
2867 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2868 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2869 + MHillasExt now derives from MParContainer instead of MHillas
2870 --> Files written with the old definition are more or less unreadable
2871
2872 - reading of reflector files
2873
2874 - display data from reflector files in the camera
2875
2876 - implemented currents (and display them in the camera)
2877
2878 - logarithmic scale in camera
2879
2880 - added class to iterate through directory contents (MDirIter)
2881
2882
2883
2884 *** Version 0.8 (2002/11/18)
2885
2886 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2887
2888 - corrected 48(!) wrong entries in the Next Neighbor table of the
2889 Magic Camera (all in the inner part of the outer ring, mostly
2890 missing a single NN)
2891
2892 - Fixed a bug in the table describing the Next Neighbours of the
2893 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2894 have any neighbour)
2895
2896 - changed trigrate.C: now it calculates the pure NSB triggers from
2897 a camera file (generated with no showers), so there is no need
2898 to introduce them by hand in the BgR array (for more details
2899 please ask Abelardo)
2900
2901 - added MHHadronness (and MHadronness) as a general facility to evaluate
2902 the quality of a gamma-hadron seperation method
2903
2904 - changed MWriteAsciiFile to accept rules (MDataChain)
2905
2906 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2907 must be replaced by calles to MWriteAsciiFile::AddColumn and
2908 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2909 changed.
2910
2911 - Implemented generalized event-matrices (one row per event)
2912 (MHMatrix)
2913
2914 - implemented the one dimensional composite probabilities
2915 (MHCompProb, MCompProbCalc, comprob.C)
2916
2917 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2918 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2919
2920 - Added a camera display displaying the pixel numbers to the
2921 event display gui.
2922
2923 - Added Monte Carlo Informations to event display gui
2924
2925 - Changed the camera display to display the pixel numbering
2926
2927 - Added three buttons to the camera display to change the palette
2928
2929 - Added the number of used and core pixels after image cleaning
2930 to MHillas
2931
2932 - Changed the algorithm used in MHillas according to TDAS 02-03
2933
2934 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2935
2936 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2937
2938 - Added fCosDeltaAlpha to MHillasSrc
2939
2940 - The numbers of photons used to calculate fConc and fConc1 in
2941 MHillasExt are now scaled with the pixel size, so that one get
2942 a four times smaller value for the bigger pixels in the outer ring.
2943
2944 - added new task to smooth the camera contents (MCameraSmooth)
2945
2946 - added possibility to use interpolated pixel values for blind pixels
2947 instead of removing it completely from the analysis
2948
2949 - Implemented the possibility to save the whole eventloop with
2950 its setup to a file. This information can be read and from
2951 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2952 and MEvtLoop::MakeMacro. If you find something not working, please
2953 report - this stuff is still in a beta phase.
2954
2955 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2956 file having crab starfield, but also for all following files - fixed
2957
2958 - MTaskList::PrintStatistics can now be instructud to print also the
2959 title, too: use PrintStatistics(0, kTRUE)
2960
2961 - Changed the image cleaning so that pixels with to many 'used'
2962 neighbors are left used (to get rid of 'holes' in events)
2963
2964 - Introduced more output to the camera displays
2965
2966 - Added an array of histograms (eg one hist per run), MHArray
2967
2968 - Added a _preliminary_ version of the reader for CT1 PreProc files
2969 (MCT1ReadPreProc)
2970
2971 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2972 (thanks to Raquel)
2973
2974 - added the first energy estimator (MEnergyEstParam, estimate.C,
2975 estfit.C) using a parametrization
2976
2977 - Added some new Monte Carlo paremeter containers used to store
2978 setup information from the MC chain (MMcConfigRunHeader,
2979 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2980
2981
2982
2983 *** Version 0.7 (2002/04/30)
2984
2985 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2986 the pedestal mean value was saved incorrectly. For files from
2987 this versions we substract 0.5 from the pedestal mean.
2988 WARNING: This may effect your results, so don't wonder...
2989
2990 - First implementation of an algorithm using only triggered events
2991 for the collection area calculation
2992
2993 - Ascii Output can now also be used for parameter containers which
2994 doesn't overload MParCointainer::AsciiWrite
2995
2996 - The Ascii Output is now also capable of writing single data members
2997 of one container
2998
2999 - You are now able to change the order of the values written to the
3000 ascii file
3001
3002 - You can now specify a conversion factor for each data member written
3003 to an ascii file. This may be usefull to change the units of the
3004 data member (eg. degrees instead of millimeters in case of the
3005 hillas parameters)
3006
3007 - Replaced old MHillas by a new structure which allows you to extend
3008 the parameters stored in MHillas very easily:
3009 see MHillas and MHillasExt
3010
3011 - Added classes to handle source dependancy of image parameters:
3012 see MHillasSrc
3013
3014 - Added container (MBinning) to have a standard input for the binning
3015 in different histograms (eg. the Energy bins should be the same in
3016 all histograms)
3017
3018 - Changed Hillas histograms from mm to deg
3019
3020 - Added the flexible binning to the hillas histograms
3021
3022 - Added a filter for the alpha parameter (MFAlpha)
3023
3024 - It is now possible to write single data members of a class object to
3025 an output stream instead of the whole container only
3026
3027 - Added a generalized filter for a data member:
3028 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3029
3030 - Added a generalized Filter parser for more difficult filter rules
3031 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3032
3033 - Added new Monte Carlo histograms:
3034 MHMcEnergyImpact and MHMcEfficiency
3035
3036 - Added many new histograms needed for the flux calculation.
3037
3038 - Added a generalized histograms which can fill and show up to three
3039 data members in either a one-, two- or three-dimensional histogram, eg:
3040 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3041
3042 - Added:
3043 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3044 * calculation of <Theta> as a function of time (MHThetabarTime)
3045 they are needed in the flux calculation in
3046 order to select for a given bin in Theta (or time) the appropriate
3047 effective collection area, which is assumed to be given as a function
3048 of Theta and the true energy
3049
3050 - Added calculation of the migration matrix in the energy
3051 (MHMcEnergyMigration):
3052 the migration matrix describes the migration from the true (E_true)
3053 to the estimated energy (E_est); it is needed to determine the
3054 distribution of E_true from the measured distribution of E_est
3055 by unfolding
3056
3057 - changed the color palette in the camera display to DeapSea.
3058
3059
3060
3061 *** Version 0.6 (2002/01/15)
3062
3063 - Introduce the option of disable pixels (MBlindPixels and
3064 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3065 able to deal with Star Field NSB.
3066
3067 - Fixed a bug in the pedestals substraction
3068
3069 - Introduced verbosity levels
3070
3071 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3072
3073 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3074 work correctly (thanks to Abelardo)
3075
3076 - Introduced correct treatment of the diffuse Night Sky Background
3077 and NSB (MMcPedestalNSB)
3078
3079 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3080
3081 - Introduced MMcRunHeaders which contains monte carlo run informations
3082
3083 - Added a 'Print'-Task (MPrint) which calls the Print function
3084 of a parameter container for each event
3085
3086 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3087
3088 - changes to be more efficient with root 3.02/06
3089
3090 - root 3.02/06 fixes:
3091 + the memory leak when reading MRawEvtData
3092 + loosing more time than necessary to update the progress bar
3093
3094 - MWriteAsciiFile is now capable of writing more than one container
3095 in a line. For example: To be able to write Monte Carlo and
3096 Hillas values (energy and alpha) in one line.
3097
3098
3099
3100 *** Version 0.5 (2001/11/06)
3101
3102 - Added new GUI functionality (Analysis)
3103
3104 - Added a camera display to be able to display events in the camera
3105 together with the calculated hillas ellipse
3106
3107 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3108 object at any state of the analysis, so that the output are several
3109 states
3110
3111 - Fixed a bug in the collection area error calculation
3112 (Thanks to Ciro and Abelardo)
3113
3114 - Fixed a bug which causes merpp to crash in some environments
3115
3116 - Implemented auto enabling scheme for Branches to speed up reading
3117 a lot (see MReadTree and MTask)
3118
3119 - Fixed a bug in the Histogram classes which caused histograms to
3120 be written to a file by MWriteRootFile without request
3121
3122 - changed the object I/O from the old stylish root I/O to the new
3123 'auto evolution scheme' This was done only for classes which are not
3124 yet used in Monte Carlo files, so that these files are still readable.
3125
3126 - Added support for a progress bar in MEvtLoop and MReadTree
3127 (see the Analysis Window in Mars for an example)
3128
3129 - Fixed a bug in the package creation which disturbed the conversion
3130 between a mars version unpacked from a tar file and the repository.
3131
3132 - Changed the code to writer merpped (converted into root format)
3133 raw files, to get faster (around 10%)
3134
3135
3136
3137 *** Version 0.4 (2001/09/20)
3138
3139 - This release is made to compile on a root version >= 3.00
3140
3141 - Fixed a bug which causes MReadTree to read the first file only
3142
3143 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3144
3145 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3146
3147 - Added a task to write several container to a root file (MWriteRootFile)
3148
3149 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3150
3151 - Added calculation of the collection area (MMcCollectionAreaCalc)
3152
3153 - fixed some bugs in the Hillas calculation
3154
3155 - added filters to be able to control the task execution dependent on
3156 a parameter (for example: the number of level 1 triggers in a MC-file)
3157
3158
3159
3160 *** Version 0.3 (2001/04/23)
3161
3162 - Many demo macros added
3163
3164 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3165
3166 - Hillas Calculation added
3167
3168 - Standard image cleaning available
3169
3170 - MReadTree is now able to handle more than one file
3171 (Remark: of the same structure)
3172
3173 - Now we are able to display events in a first version of the
3174 Camera event display. To do this we must run the macro
3175 "macros/readCT1.C" to read data from CT1.
3176
3177
3178
3179 *** Version 0.2 (2001/01/24)
3180
3181 - First Implementation of a Gui to read the raw data. Start the
3182 gui with the command mars.
3183
3184
3185
3186 *** Version 0.1 (2000/12/20)
3187
3188 - First official release 0.1
3189
3190 - Changes:
3191
3192 + changed calling style of MRawPixelIterator from do...while to
3193 while-loop
Note: See TracBrowser for help on using the repository browser.