source: trunk/MagicSoft/Mars/NEWS@ 9367

Last change on this file since 9367 was 9367, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 131.3 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * There is no need to re-run any data because no change took place which
8 could have an effect on the output. However, if you want a
9 meaningful SrcPos plot for your MCs in sponde you must re-process
10 star for your MCs first.
11
12 ;general
13
14 * fixed a few small bugs which could cause the display to crash in ganymed
15 and sponde
16
17 * in sequence file the date can now be omittet. In this case the
18 leading date with the underscore is missing in the expected filename
19
20 ;automation
21
22 * added magnetic field Azimuth direction (ARRANG), currently
23 at ~ -7deg at La Palma
24
25
26 ;database
27
28 * plotdb.php: added default (sequences) for startup, added possibility
29 to set size of plot
30
31 ;merpp
32
33 * added support for Arehucas Version >= 200812140
34
35 ;mars
36
37 * The display now also displays the trigger pattern
38
39 * The display can now display ceres reflector (_R_) files
40
41 ;ceres
42
43 * added a uniformly distributed one-bin time jitter for the start of the
44 digitization. Otherwise the first photon would be digitized always with
45 the same alignment to the bins
46
47 * Added a plot showing the production height of the photons
48
49 * Moved the particle id from the event header to the run header
50
51 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
52
53 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
54
55 * Added many new options to control the tasks. For deatils see ''ceres.rc''
56
57 * Removed obsolete plots in pedestal and calibration mode
58
59 * Removed the non-NightSky photons from the plots where they are just
60 disturbing
61
62 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
63
64 * The daq event number now represents the readout number
65
66 * The camera ''electronics'' can now be ''switched off''
67
68 * A new tab ''Info'' now display basic things like the reflector
69 layout
70
71 * Improved reading speed for corsika files
72
73 * Improved memory handling (if a large ampount of memory was needed
74 for a single event all further events were stored in the same
75 memory and it was never freed, so the program took this memory
76 until the end)
77
78 * Converted the code from MMCS' reflector program to MSimAtmosphere
79 (instead of the tables build in for MAGIC Winter and Summer
80 atmosphere we use the values written by Corsika fitted to the
81 tabulated atmosphere given as input)
82
83 * For caluclating the displayed image parameters in ceres a basic
84 image cleaning removing isolated pixels is now done.
85
86 * The magnetic field direction (ARRANG) is now taken into account
87
88 * Added plot for the energy threshold after trigger ''Threshold''
89
90 * Added plot for the effective collection area after trigger ''TrigArea''
91
92 ;star
93
94 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
95
96 ;ganymed
97
98 * added pointing model 328198
99
100 ;sponde
101
102 * The SrcPos plot for your MCs was so far meaningless because it just
103 displayes the MSrcPosCam data from the input star-files. Unfortunately,
104 this containes was never written to the star-files yet.
105
106 * A new Tab 'OnTime' is available which is an effective on-time
107 fit as in star but for all data. This is mainly for manual cross-check
108 of the effective on-time
109
110 * In some circumstances it might be necessary to re-calculate the
111 eff. on-time from the fit in the new tab, e.g. when a zenith distance
112 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
113
114 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
115 it to its own output file (for convinience)
116
117
118
119== Version 2.2 (2009/01/30) ==
120
121 ;SUGGESTION
122
123 * This release doesn't contain a major change which is expected to
124 change your results. Nevertheless there are small changes to
125 the calibration which can effect at least the first few hundred
126 events in any (mainly MUX and even more SUM) sequence a little bit.
127 So it is recommended although not necessary to reset your sequences
128 in the database before further processing.
129
130 ;NEW
131
132 * A first implementation of a Monte Carlo simulation program
133 (ceres - Camera Electronics and REflector Simulation) has been
134 implemented. It can simulate a full telescope already including
135 a complete reflector simulation and a flexible trigger and readout
136 simulation. Currently, no perfect setup is implemented and
137 especially the output of the program (data structure) should
138 be considered alpha state. Also the user interface is not yet
139 ready.
140
141 ;general
142
143 * All command line options after -- are now interpreted as
144 arguments (usually everything which doesn't start with a minus)
145 rather than options (usually everything which starts with a
146 minus). This allows to use file names starting with a -
147
148 * In all resource files you can now initialize the random number
149 generator. For details see: MJob::InitRandomNumberGenerator
150
151 * added a new program called ''readcorsika''. It's purpose is (in analogy
152 to readraw and readdaq) to read a Corsika output file (for now
153 only cherenkov output is supported) and print its contents in a
154 human readable form. It can also write the contents of this file
155 into a root-file.
156
157 * The calculation of the maximum distance to the origin in a MGeomCam
158 has been improved (edges might be further away than the sides).
159 This is just a tiny change but it might change the appearance of
160 the radial profiles a little bit.
161
162 * The default binning of the center-of-gravity plot has slightly been
163 increased
164
165 ;Database
166
167 * Added informations about the DC currents (fMinCurrents, fMedCurrents
168 and fMaxCurrents). The values are retrieved from the plots showing
169 the average DC currents of all pixels versus time.
170
171 * Websites with tables have now the opportunity to remove lines
172 ('-' button at beginning of each line) and get all lines back
173 ('+' at top of the column)
174
175 * Websites: added option to query only sequences containing sumtrigger
176 events
177
178 * Websites: added option to group by date (year, month, night) for runs
179 and sequences and enabled that combining of different group-bys,
180 e.g. status, date and source is possible
181
182 ;automatic analyis
183
184 * Rewritten producing plots in the web.
185 New plots, namely the output of plotoptical.C (extinction curve from
186 KVA), plotstat.C (status of the automatic analysis (percentage of
187 processed, analysed data etc.)) and plotusage.C (statistics of the
188 condor usage in the data center) has been are available now next to the
189 plots of plotdb.C
190 Mean values from the plots (output of the macro) are provided in a
191 txt file now.
192 The creation of the plots for callisto, star and ganymed in the web is
193 now steered via database. Consequently the plots are faster and
194 reliable up-to-date.
195 For all plots, a new layout is available facilitating the browsing
196 through the plots and providing additional information on the
197 displayed values. (tabs.php) These plots are linked from the DB
198 websites and the wiki.
199
200 ;statusdisplay
201
202 * The ''Loop'' entry in the menu bar now contains an option to pause
203 the loop and to process single events.
204
205 ;merpp
206
207 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
208 instead of RunHeaders)
209
210 * Now allows to merpp files newer than 2008/09/03.
211
212 * Added fixes for wrong (wrong or double) run- and file-numbers
213 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
214
215 ;callisto
216
217 * Extracting the pulse position for the pulse position check events
218 with sum trigger were denied. This decreased the statistics
219 extremely and therefor the resulting puse position was calculated
220 quite weak. Now sum events pass the calculation if and only if they
221 have also a level 1 trigger.
222
223 * the extraction of pedestal events and pulse position from the
224 first data events is now more automatic and makes sure that
225 a more precise number of events is extracted independent of
226 the ratio with which pedestal events or events with signals
227 are contained in the data.
228
229 * Updated Muon calibration constants for all MUX data (teh changes were
230 all smaller than 5%)
231
232 ;star
233
234 * For the calculation of the effective on time all sum-triggered events
235 were skipped. Now all Level1-triggeres events will pass. This might
236 result in a slight inaccuracy of the effective on time.
237
238 ;ganymed
239
240 * If the source position is more than 1deg away from the camera
241 center an error is raised now.
242
243 * Hopefully fixed the bug ''ganymed crashes when resized''
244
245 ;sponde
246
247 * Fixed a problem which causes the fitted spectral slope to be displayed
248 incorrectly. If you use MJSpectrum::FormFlux in your macros make
249 sure that the parameter 0 of your fit is negative.
250
251 * Added a histogram showing the read source position of your MCs
252
253
254
255== Version 2.1.1 (2008/08/04) ==
256
257 ;Database
258
259 * Added the median number of photo electrons from the calibration
260 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
261 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
262
263 * Added fTotOnTime, which is the on-time as given by the run-headers
264 (in contradiction to fAbsOnTime which comes from CC)
265
266 * Added new primaries for the new data structure (Magic II): for the
267 tables dealing with sequences (SequenceBuild Status, Sequences,
268 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
269 this is the telescope number (fTelescopeNumber) for the tables dealing
270 with runs (RunData and RunProcessStatus) this is in addition the file
271 number (fFileNumber)
272
273 * Added column fPriority to the status tables to be able to steer the order
274 in which the data is processed. As default the run, sequence and dataset
275 number are used.
276
277 ;automatic analyis
278
279 * Adapted scripts to the new data structure: They can handle now different
280 telescopes (getting the information as usual from the database).
281 The paths for Magic 2 are not yet implemented.
282
283 ;general
284
285 * should work now with root 5.20/00 (please note that root 5.20/00
286 we encounter crahses in the status display which are ot yet
287 understood)
288
289 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
290 instead of the base name of the file. This makes them easier to
291 access from the code
292
293 * Default Monte Carlo names in MSequence do not require the _E at
294 the end anymore
295
296 * where abrrevating a sequence file with a sequence number is possible
297 also "telescope:sequence" is now accepted, e.g.:
298 star 2:2000123 --out=output
299 see the programs' help for more details.
300
301 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
302 from the database. See the constructors for more details.
303
304 * MReadTree now supports friends
305
306 * MReadTree can now read also files not written by MARS and store
307 the data encapsulated in emulated MParContainers
308
309 * added a new starguider calibration valid since 15.1.08
310
311 ;showplot
312
313 * showplot can now read more than one file at once. This is especially
314 inetersting if reading files containing pure canvases
315
316 ;merpp
317
318 * we merpp the dc currents now also from the camera reports (they have
319 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
320
321 * In the automatic analysis we omit merpping of the currents from the
322 caco files and use the lower rate camera reports from the cc files
323 instead
324
325 * merpp has been redisigned to allow merpping of the cc-reports
326 of a whole sequence. This allows to design a very simple analysis:
327 mkdir output
328 ./callisto 100776 --out=output
329 ./merpp 100776 output
330 ./star 100776 --ind=output --out=output
331 Instead of the sequence number also sequence files are accepted.
332
333 * Implemented a fix for run-numbers between 1001348 and 1001396
334 which were incorrectly assigned by the cc.
335
336
337 ;callisto
338
339 * added a filter again which was was removed in the last release.
340 it removed the most brightest events. This should not change
341 any analysis result because these events are so bright that
342 they cannot be analysed anyway, but the bad-pixel plots doesn't
343 show outliers.
344
345 * updated muon calibration constants for the periods 51-57,
346 58-63 and 67-
347
348 ;star
349
350 * The camera currents are now displayed with the rate of the camera
351 reports instead of the caco reports
352
353 ;ganymed
354
355 * if mc camera files are new enough (>=8) the source position in the
356 camera is now calculated from the stored telscope and shower
357 orientation (Note, that this might not be suitable in all cases
358 depending on the aim of the study. These case still needs
359 implementation)
360
361
362
363== Version 2.1 (2008/06/18) ==
364
365 ;Database
366
367 * introduced average temperature and wind speed from star-files
368
369 * introduced average values from Pyrometer (mainly Cloudiness)
370
371 * introduced the ratio of accepted calibration events in the
372 calibration run
373
374 * introduced the average rates of the different trigger pattern,
375 e.g. the rate of pedestal and calibration events, from the signal-file
376
377 ;general
378
379 * fixed GroupBy options in plot*.C macros
380
381 * only display KVA points (not the Tuorla points) in plotoptical.C
382
383 * all programs now allow to add resources to the ones from the resource
384 file or overwrite them from the command line. This can be done like this
385 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
386 if something seems to be wrong you can debug what the program is doing
387 using the option --debug-env=3
388
389 * increased the diversity of debug levels. That also means that with -v3
390 you get now less output, i.e. only the output which is important for
391 an analysis. To get more output which helps for debugging try 4, 5 and 6.
392
393 * fixed a problem in the task synchronizing the reading of the reports
394 and the data stream. The effect was that in some circumstances the last
395 events of some trees could have been skipped. Since this is only a
396 very tiny part of the data no severe effect to your analysis results
397 is expected (an exception might be very short, i.e. singel runs,
398 datasets).
399
400 * Dataset file now allow to include the sequence file directly within
401 the dataset file and also allow to exclude single runs from the dataset.
402 (for more details see Class reference of MDataSet)
403
404 * Sequence files now allow for excluding runs from the analysis
405 (for more details see Class reference of MSequence)
406
407 * added code to process the sum-trigger flag
408
409 * the histogram classes MH3 and MHn now support profile histograms
410
411 * the histogram classes MH3 and MHn now support labels at the axis
412
413 * the Random Forest Train-classes (MJTRain*) now store the used datasets
414 in the output file
415
416 * the MFMagicCuts have a new option to allow a linear area cut (for
417 special studies)
418
419 * The liniking of the shared object is now done into a file defined
420 by 'mktemp'. This should be a local file system which accelerates
421 liniking a lot.
422
423 * The code has been prepared for compilation with root 5.18/00d
424
425 * The MHEnergyEst histogram now shows the distribution of
426 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
427 and (Eest-Emc)/Emc vs Emc.
428
429 * fixed mars (event display) for merpped raw-data and MC data
430
431 * adapted the synatx of sequence files to allow for the new run/file
432 scheme. For more details see class description of MSequence
433
434 ;showplot
435
436 * Added support for tiff files
437
438 * Added support for csv files (tables containing tab number,
439 name and title)
440
441 * Tabs now can have a title which is displayed in the postscript file
442
443 * When multiple file are written at once (e.g. pngs from a display)
444 it is now possible to use the tab name and or tab number in the
445 file name. For details see showplos's help.
446
447 ;merpp
448
449 * Implemented cc file version 2008-02-20/0
450
451 * Implemented cc file version 2008-05-19/0
452
453 * With new options merpping can be restricted (in addition to the
454 run-number) also by telescope and file number.
455 For details see "merpp --help"
456
457 * Implemented raw data format 11 (the most important change, except
458 from plenty of changes in the format definition, is the addition
459 of the file-number in the header) If nobody makes a mistake this
460 format should have the advantage that it is by definition forward
461 compatible, so old programs will be able to read newer formats.
462
463 * Added Pyrometer information to default output (stored in a new Tree
464 Pyrometer, needs a complete new merpp, i.e. new calibration)
465
466 * Merpping (also update) can now be restricted to one single report.
467 For example:
468 If you want to update an old file with Pyrometer information call
469 merpp --only=Pyrometer --update
470
471 ;callisto
472
473 * in the pedestal processing now at least 50 processed events are
474 required for succeeding.
475
476 * the signal and calib files now contain also the sequence information
477
478 * the two MPedestalCam in the calib file now have proper names
479 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
480
481 * Both pedestal cams now contain the number of events processed
482
483 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
484 i.e. for the extraction of the calibration pulses basically the average
485 over all events of the first slice instead of all slices was used.
486 Since pedestal and calibration constants are continously recalculated
487 this only effected the very first events of every sequence.
488
489 * For the extraction of the position of the maximum sample now the
490 extraction range is set automatically to the extraction window,
491 before the whole accessible range was used.
492
493 * If the number of samples in the events and the number of samples
494 in the run-header disagrees now an error is raised (this can
495 happen in not well simulated Monte Carlo files)
496
497 * In the case of MUX-data pedestal events with the lvl1 trigger flag
498 could survive into the pedestal calculation -- fixed.
499
500 * Tab "TrigPat" added showing the distribution of the trigger pattern
501 as found in the run-files (normalized with the run length)
502
503 * The selection of events from the trigger pattern has been improved.
504 If the trigger pattern is corrupted events won't pass anymore.
505
506 * Added a new command line option --dev-null to suppress output of
507 Y-files (this is useful for test cases)
508
509 * added a new tab "CalPos" showing the arrival time of extracted
510 interleaved calibration events
511
512 ;star
513
514 * the star file now contains also the sequence information
515
516 * Added a new command line option --dev-null to suppress output of
517 I-files (this is useful for test cases)
518
519 * Tab "Rate" added showing the distribution of the trigger pattern
520 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
521 the Y-files (normalized with the run length)
522
523 * The effective on-time calculation doesn't use events with only
524 sum-trigger anymore
525
526 * The data in the MHWeather tab has been reorganized. The never
527 working solar radiation has been removed and the data from
528 the pyrometer (cloudiness, air and sky temperature) is
529 displayed in addition.
530
531 ;ganymed/sponde
532
533 * Now data points are even shown correctly if they have error bars larger
534 than one sigma. Points with null or negative significances are omitted.
535
536 * DrawNicePlot now allows to set a projection range
537
538 * Updates pointing models. One is applied after the implementation
539 of the new LUTS in August, the other one is applied after the
540 next major change of the pointing model in October. Note that
541 these models are preliminary and give wrong results below Zd=65deg
542
543 ;sponde
544
545 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
546
547 * a new option "--force-runtime" is available. In case of very short
548 datasets (for light-curves) which are in the order of a few
549 minutes the calculated effective on-time is not very acurate because
550 it is quantizised in the order of a minute. Therefore you can switch
551 to using the real run-time instead (remakrt: this ignores any
552 dead-time!)
553
554 * a more analytical way is used to "fill" Monte Carlos into regions
555 of impact parameters which have not been simulated because the
556 trigger efficiency is assumed to be 0.
557
558 * estimated sensitivity curves for hi and lo zenith angles are shown
559 scaled to the correct observation time and collection area
560
561 * the Monte Carlo events after cuts are now written to the output file
562 if an output file given
563
564
565
566 *** Version 2.0 (2007/09/03)
567
568 - database: the position used for the pulse pos check was missing
569 in the callisto output and could thus not be filled into the DB.
570 Also the old values seemed not exactly the PulsePos used for
571 teh check.
572
573 - general: Resource file now allow an Include-Resource, i.e. you can
574 read a resource file with default settings, include it in your
575 resource file and overwrite the settings in your file. More than
576 one include file is allowed. Inclusions can be iterative.
577 Include: mydefaults.rc yourdefaults.rc
578 The resources in the first file have higher priority than the
579 second file.
580
581 - general: Now the output files (calib*.root, etc) also contain the
582 resource file (to check it open it in the TBrowser and choose Print()
583 from the context menu)
584
585 - general: Dataset files now allow to overwrite the default path
586 to search for sequence and data files. Note, that the program
587 option and individual resources will overwrite it. For example:
588 SequencePath: /magic/montecarlo/sequences
589 DataPath: /magic/montecarlo/star
590
591 - general: Fixed a problem with variables in MDataPhrase. It seems
592 that only optimdisp (didn't work) was effected.
593
594 - general: Some improvements to the optim and train processing. For
595 example the ststud window now got a proper title.
596
597 - general: The "Status Display: " was removed from the window title
598 within an Eventloop.
599
600 - general: added a new flexible histogram-class (MHn) which can be used
601 for example in testing after optimizations or training to produce
602 user defined histograms.
603
604 - general: The Random Forest now allows attaching an evaluation
605 function which is applied to its output. This allows to train
606 on whatever you like (eg. train on log10(energy), but return
607 energy)
608
609 - general: The Random Forest training of energy (trainenergy.c) and
610 disp (traindisp.C) has been improved by more graphical output to
611 judge the result.
612
613 - general: The training of energy (trainenergy.C) has been improved
614 a lot by training on a different quantity than energy. It gives
615 a result which is highly independant of the source spectrum
616 and shows lower bias than all other options.
617
618 - general: Dataset files are allowed to contain collections of
619 datasets. For more details see the class reference of MDataSet.
620
621 - general: The default WobbleMode in a datset file now (if not
622 overwritten) is "auto", i.e. wobble mode is set if the dataset
623 doesn't contain off-sequences.
624
625 - merpp: Merpp can read file format version 9 now. Please realize
626 that for file format version 9 the extraction range is different
627 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
628 the first and last 15 slices have been removed from all MUX data.
629
630 - mars: Similar to writing movies you can now select events which
631 should be displayed in your display. Therefore add the following
632 lines to your mars.rc:
633 MFEvtNumber.FileName: ganymed00223552.root
634 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
635 The input file can be a ganymed-file after (ganymed*.root) or
636 before (ganymed*-summary.root) file. For example to select all events
637 from your on sample after cuts (excluding the ThetaSq cut) use
638 MFEvtNumber.Selector: DataType.fVal>0.5
639 To show all events from your on-sample after quality cuts
640 use the summary file instead.
641
642 - mars: new ways to call mars are implemented. Instead
643 of calling
644 mars filename.root
645 you can now also use
646 mars sequence.txt
647 or
648 mars sequence.txt inputpath
649 or replace sequence.txt by the sequence number if the default
650 sequence file should be used.
651
652 - mars: The default size has been increased
653
654 - mars: There are two new heckboxes which allow to switch off
655 the calculated image parameters
656
657 - callisto: was broken for MCs... fixed.
658
659 - callisto: improved calculation of spline coefficients a lot. This
660 leads to a further improvement of the event rate calibrating MUX
661 data of about 15% (175evt/s instead of 150evt/s)
662
663 - callisto: finally the raw data we read is now real 16bit (with
664 10bit precision) for MUX data and not a stripped 8bit number
665 anymore. Due to scaling of the numbers (without precision loss
666 into an [0-256[ range, the final numbers for pedestal, pedestalrms
667 and extacted signal don't change. However, at all places where
668 raw data is directly accessed (eg. saturation and variation
669 limits in the signal- and pedestal-extraction) the numbers
670 refer still to the data's 16bit range.
671
672 - callisto: The maximum arrival time difference used in the bad
673 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
674 for both, old FADC and MUX-FADC, data.
675
676 - callisto: Be aware that callisto is now calibrating the arrival time
677 in nanoseconds rather than time slices. Also all following tasks
678 have been changed to assume ns units now. If you star data
679 calibrated with an older version it might be necessary to adapt
680 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
681 to obtain optimal results. The plot in the PulsePos tab
682 will now be in ns, too. This might also mean that the Muon
683 analysis in star might not work as perfect as expected as long
684 as old files read in.
685
686 - callisto: The calibration constants of earlier updates got lost
687 somehow. All constants have been updated.
688
689 - star: The PSF is now determined from the profile of the ArcWidth
690 instead of arcwidth/radius. The old way gave to much weight
691 to the bins with low statistics. The reference lines have been
692 updated.
693
694 - star: For speed reasons events suitable for the muon analysis
695 are now also preselected by fConcCOG<0.1 which seems to be a very
696 good preselector for muons.
697
698 - star: is now calculating a new timing parameter the Slope along
699 the major and minor axis of the shower. Therefore a numerical
700 solution of a line-fit is used. To use MHillasExt.fSlopeLong
701 and MHillasExt.fSlopeTrans don't forget to multiply it with
702 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
703
704 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
705 have been removed from MNewImagePar. They have never been good for
706 anything.
707
708 - star: Implemented a new recursive algorithm which is supposed to be
709 faster. Also implemented new cleaning oiptions, which are:
710 + CleanLevel0:
711 The cleaning level above single core pixels can be kept
712 + KeepIsolatedPixels:
713 Define whether single core pixels should be kept
714 + TimeLevel1:
715 The coincidence window in nanoseconds to single used neighbors
716 + TimeLevel2:
717 The coincidence window in nanoseconds to two used neighbors
718 + PostCleanType:
719 MOde in which a time dependent post cleaning should be applied
720 0: No post cleaning
721 1: Require for each used pixels at least one used neighbor
722 within a time-window of CleanLevel1
723 2: Require for each used pixels at least two used neighbor
724 within a time-window of CleanLevel2
725 3: Require first two and second one used neighbor
726 within a time-window of CleanLevel1 and fCleanLevel2
727 respectively
728 + RecoverIsolatedPixels:
729 - recoveres isolated core pixels if they have a used neighbor
730
731 - mars/star: The new default cleaning is:
732 + CleanLevel1: 6.0
733 + CleanLevel2: 3.0
734 + CleanTime1: 1.75
735 + CleanTime2: 1.75
736 + PostCleanType: 3
737
738 - star/ganymed: The old spark-cuts have been replaced by new ones.
739 These new spark cuts have been cross checked with the sequences
740 84720 (before splitter), 101041 (after splitter) and 223539 (new
741 FADCs). In all cases they seperate pretty well, but of course not
742 perfect. Monte Carlos have suggested to tighten the cuts a little
743 bit further at low sizes. This has been done.
744
745 - ganymed: IMPORTANT - The spark cuts have been changed to match
746 all available data more or less well. This might mean that for
747 YOUR data there are still sparks visible.
748 Whenever you do an analysis you have to make sure that NO sparks
749 survive your cuts!
750
751 - ganymed: The old hadronness and size cuts have gotten new indices
752 (10, 11). The old indices 8 and 9 now mean an additional condition
753 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
754 If you want to switch off this cut just move the line far away enough,
755 e.g. by setting c[9] to -500. Please update your ganymed.rc files
756 accordingly!
757 The unit of c[9] is deg. It is the dist at which your cut will
758 cross the slope==0. The unit of the slope is ns/deg. So if
759 you readin files calibrated with an older Mars-version you
760 have to adapt the default value for c[9] to the FADCs:
761 - Multiply by two for the MUX FADCs (run number > 200.000)
762 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
763 - Multiply by 42 for the meaning of life (run number = 200.000)
764
765 - ganymed: The old Cut0 is now called CutQ and is calculated before
766 the source position is caluclated. If you need a quality cut
767 including source dependant data (be very carefull with this!)
768 you have to use Cut0 instead.
769
770 - ganymed: now properly supports three off regions in wobble mode.
771 It will be the default from now on in ganymed_wobble.rc. To change
772 the number of off-regions use
773 NumOffSourcePositions: 1
774 in your ganymed.rc. Also by default no off-theta cut will be done
775 anymore so that you will get a background level higher than the
776 signal level in your ThetaSq plot for ThetaSq>0.2.
777 Due to this be carefull changing the scaling mode away from
778 "None". You will underestimate your signal if your scale interval
779 is not properly set.
780 (Rem: ThetaSqN is no longer needed)
781
782 - ganymed: is now storing the events of all (on- and off-)
783 source positions even in the case of more than one off-source
784 position. This should allow sponde to work properly and the
785 energy estimation is done correctly in all cases (without any
786 "nearest position" trick)
787
788 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
789 with a real pointing model for the starguider is done, calibrated
790 with more than thousand tpoints taken from this date on.
791
792 - ganymed: was broken for Wobble-MCs... fixed.
793
794 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
795 has changed. Note that your old ganymed.rc will be incompatible
796 with the new algorithms! Please check the ganymed.rc files and
797 the class description of MFMagicCuts for more information.
798 It is recommended at the moment to use identical Disp-Parametrizations
799 for on/off- and wobble-mode. If cuts are optimized only
800 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
801 should be optimized. All other values should be kept as they are.
802 If you want to do an anylsis without timing a parameters, you can
803 switch off the timing cuts by seeting parameter 7 to a very small
804 value (eg. -99). To remove the slope parameter from the disp
805 paremtrization set parameter 8 to 0.
806
807 - ganymed: The distribution of observation time versus zenith
808 angle is now shown for off- AND on-data.
809
810 - ganymed: The contents of the source position plot are no longer
811 averaged, thus a lot of (fake) events between the two wobble
812 positions have disappeared.
813
814 - ganymed: There is a new tab "CutT" it contains the VsSize plots
815 with the CutT, whihc is defined in ganymed.rc, applied. It
816 is resonable to use your theta-cut for it, to see if there is
817 something strange (sparks!) in your signal-region.
818
819 - ganymed: To choose a dataset from a collection in a dataset file
820 use the new command line option "--dataset=12345"
821
822 - optim, sponde: should now properly support three off-regions.
823 Just produce your ganymed summary files with three off-regions.
824 optim and sponde will automatically get all off events from
825 all off-regions from this file. Please do not forget to
826 set the scaling in optimwobble.C properly:
827 fit.SetScaleUser(1./3);
828 it is not yet read in automatically (will follow soon).
829 In the case of fixed Scale you can also use
830 cuts.SetThetaCut(MFMagicCuts::kOn);
831 no off-cut needed.
832 Be carefull in case of three off-regions when switching on
833 scale mode. Make sure that the scale interval is set correctly.
834
835 - sponde: sponde.rc and sponde_onoff.rc are now idetical
836
837 - sponde: the resouce files have been rewritten with a lot of
838 comments and a well working parametrization for an energy estimator
839
840 - sponde: In the estimated energy versus monte carlo energy plot the
841 contents where exchanged.... fixed.
842
843 - sponde: the so called "accurate"-mode has been removed. It didn't
844 give any improvement in accuracy, only decreased execution speed.
845
846 - sponde: the so called "simple"-mode has been removed. It didn't
847 give any improvement in simple.
848
849 - sponde: the so called "refill"-mode has been removed. It was anyhow
850 not implemented.
851
852 - sponde: now checks whether the theta distribution of your on-data
853 and the theta-distribution of your Monte Carlo sample (after
854 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
855 sample is incomplete) execution is stopped. Execution can be forced
856 using the new option --force-theta. Use this option with care!
857
858 - sponde: Proper collection areas can now be constructed also from
859 Monte Carlo samples generated with different maximum impact
860 parameters. Note that in previous version you neither got
861 a warning or failure, nor was there any obvious sign that the
862 collection area was overestimated due to usage of files with
863 different maximum impact parameters.
864
865 - sponde: If MC files with different lower energy limits are used
866 the primary MC spectrum is artificially completed down to the
867 lowest energy used at all. WARNING: that this gives correct
868 collection areas ONLY if none of the events in this region would
869 survive your cuts at all.
870
871 - sponde: the output file now contains more information about
872 the spectrum (eg. the full 2D collection area histogram).
873 Note, that this information can only be written to the file
874 if it is stored automatically via command line argument.
875 If you only store the status display from within the display
876 the information is lost.
877
878 - sponde: added a new tab "Disp". It shows the residual of the disp
879 (Disp-Dist) versus several parameters and it is meant to judge the
880 quality of the disp estimator. In the ideal case the residual is zero
881 and doesn't depend on any variable. The tab is displayed after
882 CutQ and Cut0.
883
884 - sponde: added a new tab "Energy". It shows the residual of the
885 energy (lg(estimated energy)-lg(monte carlo energy)) versus
886 several parameters and it is meant to judge the quality of the
887 energy estimator. In the ideal case the residual is zero
888 and doesn't depend on any variable. In reality even a good estimator
889 can show residuals versus Monte Carlo energy. The tab is displayed
890 after all cuts.
891
892 - sponde: added a new tab "EventDist" showing the unweighted real
893 absolute number of events of your sample after cuts. This tells
894 you how many events with this energy you had in your MC files.
895 The same information you get from the error bars of the weighted
896 histograms, but this is less intuitive.
897
898 - sponde: The spectrum plots now show the crab- and 1553-spectrum
899 for comparison. It is not meant to show these curves in
900 publications, they are only for production.
901
902 - sponde: The OriginalMC tree with the events produced by corsika
903 is now processed only once
904
905 - sponde: Finally fixed most annoying bug, which has effected the
906 last bin of the collection area. It was the problem that binnings
907 of root histograms are from 1 to n (included) but there was a C-like
908 loop in sponde from 0 to n (excluded). Now the loop also includes
909 correctly under- and overflow-bins. The worse thing with this is,
910 that for the events in the highest bin not only the bin-content
911 was wrong, but also the weights applied to these events, which could
912 in pricipal effect also other parts of the distribution (eg. due
913 to energy estimation). Fortunately it effected only a few events
914 in most cases.
915
916
917
918 *** Version 1.2 (2007/05/14)
919
920 - database: The database now has two new values Unsuitable50 and
921 Unsuitable01. They express the number of pixels which are
922 unsuitable for more than 50%, respectively more than 1%, of
923 all calibrated event. It is a more accurate number than the
924 previously used numbers, because they only take the first
925 calibration (ignoring the interleaved calibrations) into account.
926
927 - database: The database now has two other new values UnsuitableMax and
928 DeadMax. They express the maximum number of pixels which were
929 unsuitable, respectively dead, during the sequence. Because
930 of high pedestal rms (cars passing) a few events with very high
931 numbers of unsuitable pixels can happen. Not to suffer from this
932 effect we don't take the highest 0.1% of the numbers into account.
933
934 - general: fixed a bug which caused callisto and star to stop working
935 properly because the callisto output was currupted
936
937 - general: a script called scripts/makemovie has been added which
938 simplified the process of producing several movies from a single
939 sequence with different setup.
940
941 - callisto: Some more code cleanup. Started to remove old obsolete
942 code from cvs.
943
944 - callisto: The extraction of the pedestal with the extractor was
945 not random. It seems that extracting at one position is still biased
946 (for example in the first or last slices we could still suffer from
947 switching noise) Now it is completely random.
948
949 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
950 pedestal files) individual pixels could be skipped due to high
951 variations. This was already the case for the pedestal extraction
952 from the lo-gains since the beginning and properly handled
953 there, but was introduced in the extraction from the pedestal files
954 a while ago. To calculate the average value it was still divided
955 by the number of events procesed not by the number of summands
956 really summed. This let to a pedestal which was a tiny amount too
957 small (for a few piels in the order of 0.1%). This led to an slightly
958 positive offset of the randomly extracted pedestal for a few pixels.
959 I doubt that this has a big effect on the result, because the effect
960 on the individual numbers is quite small. Due to this it is suggested
961 that you rerun your calibration to make sure you are without any
962 avoidable bias.
963
964 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
965 the median rms of the absolute arrival time and expressed in significance
966 levels. This replaces the old meaning of an abolute upper limit. An
967 absolute upper limit doesn't make much sense, because in our data
968 all arrival times are shifted at the same time (in fact it might be
969 a shift of the artificial trigger w.r.t. to the light flash).
970
971 - callisto: Added a new tab "BadPixTm" which shows the time evolution
972 of the number of unsuitable pixels over the whole sequence. This
973 is usefull mainly to judge if an intermediate calibration had
974 problems.
975
976 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
977 of the number of dead pixels over the whole sequence. Dead pixels
978 in this context are unmapped pixels, i.e. pixels which could not
979 be interpolated, and thus are ignored in the further analysis.
980
981 - callisto: It is now possible to use the position of the maximum
982 of the spline as arrival time instead of the leading edge even
983 when using the integral for the signal. Therefor set the extraction
984 type to kIntegralRel ("IntegralRelative") and the relative height
985 ("HeightTm") to -1:
986 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
987 MJPedestalC1.ExtractSignal.HeightTm: -1
988
989
990
991
992 *** Version 1.1 (2007/04/27)
993
994 - general: The new class MGeomCamDwarf contains the camera geometry
995 for our prefered Dwarf camera and can be used to create general
996 geometries of roundish or hexagonal cameras.
997
998 - mars: The default cleaning is now abolute 8.5/4.0.
999
1000 - mars: The resource file mars.rc now contains examples for MUX data
1001
1002 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1003 data containing only 10-bit information is still cooked down to
1004 8-bit, by cutting away the lowest 8-bit.
1005
1006 - merpp: When reading raw data the data is now stored in a single
1007 array. The lo-gain array is obsolete. The interface stays the same.
1008
1009 - callisto: To process the new MUX data use the resource file
1010 callisto_mux.rc
1011
1012 - callisto: The -root and -raw options to read merpped raw data have
1013 been removed
1014
1015 - callisto: If the -mc option is given the sequence-name can now be
1016 replaced by the MC sequence number
1017
1018 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1019 -mc option can now be omitted
1020
1021 - callisto: Started further simplification by removing obsolete
1022 dependancies on MCalibIntensity*Cams.
1023
1024 - callisto: removed unsused intensity calibration from MJCalibration
1025 for further simplification
1026
1027 - callisto: for simplification removed references to
1028 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1029 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1030 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1031 (this should at minimum change nothing at all, and at maximum
1032 improve thing if these containers where somewhere not handled
1033 properly)
1034
1035 - callisto: Added the option to write an event movie. Please use
1036 this option with care (huge files) but exessively to understand
1037 our events. For further documentation please refer to the
1038 IACT wiki
1039 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1040
1041 - callisto: Improved binning for the pulse position check histogram
1042
1043 - callisto: The code calculating the pulse position checknow takes
1044 the pedestal into account
1045
1046 - callisto: The arrival time is now stored with full precision this
1047 helps to get rid of artefacts in histograms. For the signal this
1048 is not necessray because it is displayed in log-scale anyhow
1049
1050 - callisto: Fixed a problem with internal exclusions. Pixels which
1051 have once been marked as unsuitable didn't get the necessary
1052 histograms filled anymore to be rechecked with each interleaved
1053 calibration.
1054
1055 - callisto: The relative arrival time resolution (the rms of the
1056 relative arrival time offset) is now checked against its
1057 median and the median deviation, instead of the average
1058 plus an absolute offset.
1059
1060 - callisto: The relative arrival time offset is now calculated
1061 w.r.t. its median not w.r.t. to an artificial reference pixel.
1062
1063 - callisto: The relative time calibration now marks pixels with
1064 outlaying offset as unsuitable
1065
1066 - callisto: The interleaved relative time calibration has been switched
1067 on. The advantage is that pixels which are marked as outliers
1068 now can recover. An improvement over time is not expected, because
1069 the relative time calibration seems stable.
1070
1071 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1072 option can now be omitted.
1073
1074 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1075 or the option "-mc" is specified as default the monte carlo datacenter
1076 paths (/magic/montecarlo/...) are used if not overwritten in the
1077 dataset file.
1078
1079 - ganymed: The output files now contain run- and event-number for all
1080 events, accessible as RunNumber.fVal and EvtNumber.fVal
1081
1082 - ganymed: Added a plot showing the source position in the camera also
1083 for wobble mode
1084
1085 - ganymed: In addition to the existing task which can be setup to
1086 be executed after Cut1 a final task called "EstimateEnergy"
1087 has been added, executed before writing the final output
1088 (ganymed00000000.root). The task setup in all three cases
1089 can be choosen individually. (For all three(!) cases you
1090 can for example choose MRanForestCalc. For examples see all
1091 sponde*.rc and all ganymed*rc)
1092
1093 - ganymed: If a container "MEstimatedEnergy" is found in the
1094 parameter list (eg. because it was setup by MEstimateEnergy)
1095 it will be written to the output file.
1096
1097
1098
1099 *** Version 1.0 (2007/02/16)
1100
1101 - database: Website to plot values from the database has been added.
1102
1103 - database: The rate of spark events as found by star is now kept
1104 and the rate after cleaning is now with spark events subtracted
1105
1106 - general: The changes to the interpretation of phrases lead to
1107 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1108
1109 - general: Added example files how you can create your own calendar
1110 (eg. as christmas present) with Mars. Just run
1111 root macros/tutorials/calendar.C
1112
1113 - general: Added a possibility to display grouped data in the plotdb.C
1114 macro (and similar macros). This allows to plot hourly, nightly,
1115 weekly, monthly and yearly averages.
1116 For more details see the plotall function of the macro
1117
1118 - general: fixed the error display of the camera display. It showed
1119 wrong results.
1120
1121 - general: fixed a memory leak when reading many MStatusDisplays
1122
1123 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1124 between a spherical and a parabolic mirror
1125
1126 - callisto: We have a new pulse position check which takes the properties
1127 of the extractor automatically into account. So no need to set
1128 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1129 left is done. If possible the lo-gain extraction start and hi-gain
1130 extraction end is changed accordingly. If no proper extraction range
1131 can be set (hi-gain too much to the left) an error is raised.
1132
1133 - callisto: New swapped pixels have been found and corrected
1134
1135 - callisto: Redone the signal extraction this includes:
1136 + Unified the algorithms to extract the pedestal for all pedestal
1137 extractions done
1138 + Unification of hi- and lo-gain into one array
1139 + Unification of hi- and lo-gain extraction for Spline and
1140 Digital Filter (means now exactly the same algorithm is used,
1141 not a copy-and-pasted one)
1142 + Store pedestal subtracted data in a common place
1143 + Improved extraction algorithms. If the algorithms search a
1144 maximum but don't find one they don't return the maximum anymore
1145 + Improved the extraction such that a information for signal
1146 and time which is consistent is returned
1147 + replaced the numerical spline with a (not slower) analytical
1148 solution
1149 + Lowered the saturation limit from 250 to 245 to make sure that
1150 we are far away in all pixels from problems with the clock-noise
1151 + The start of the lo-gain extraction is calculated from the hi-gain
1152 arrival time. In case of saturation an estimation is used.
1153 + the hi-gain window was extended to slice 16. This allows extraction
1154 of very late pulses in single pixels or of huge hadron showers.
1155 + Now uses the lo-gain extraction range for pedestal extraction,
1156 not the hi-gain range in the lo-gain
1157
1158 - callisto: New hi-/lo-gain calibration constants have been produced
1159 for all periods from the statistic of the whole period. They are
1160 now used automatically depending on the periods. The old constants
1161 where deviation in avarega about 2%-3%. The constants are very
1162 stable from period to period (<<1%) except for exchanged channels.
1163 In a few cases the constants used so far were off by 1%-2% (maybe
1164 temperature effects?)
1165
1166 - callisto: To gain obsolete space we do not write the
1167 MPedestalFundamental anymore. Also calibration and bad pixel
1168 treatment is not done for it anymore because it has never been used.
1169
1170 - callisto: Fixed a bug in the seuqence handling which caused the
1171 light condition to be ignored
1172
1173 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1174 basically the same as "Cleaned" but the distribution devided into
1175 the events fullfilling a spark cut or being rejected by it.
1176 This cut can be changed from star.rc (see example inside) by
1177 the "SparkCut" directive
1178
1179 - star: Star displays now the average individual pixel-rate (IPR) versus
1180 time and the average discriminator threshold (DT) of all pixels.
1181
1182 - optim: fixed a problem with the optim-macros which was due to a bug
1183 in the new phrase parsing
1184
1185 - ganymed: To get a nice FalseSource plot (instead of the all-information
1186 debug plot displayed as a standard plot) use the context menu
1187 somewhere between the two upper plots, click on "DrawNicePlot"
1188 and enjoy the result. (It is the same context menu which contains
1189 the other options)
1190 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1191
1192 - ganymed/optim/train: The cut program, trainings- and optimization
1193 macros could run with less files found than expected from the
1194 sequence-files. No the execution is stopped in this case.
1195
1196 - ganymed: now stores the dataset in the output file with all information
1197 contained (as sequence number, sequence path, data path) so that the
1198 used dataset file can be recreated complete from the output
1199
1200 - sponde: now also allows the uasge of random forest
1201
1202 - sponde: added a plot showing the cut efficiency
1203
1204 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1205 errors (eg. effecting the collection area) because the errors of the
1206 two histograms were swapped in the calculation, which makes a difference
1207 in the case the histograms contains weighted events. Aditionally the
1208 totalarea was incorrectly taken into account, which results in too small
1209 errors, which makes a difference at low statistics were the errors
1210 or the collection area dominate.
1211
1212
1213
1214 *** Version 0.10.3 (2006/10/23)
1215
1216 - database: Implemented ObservationMode flag in websites.
1217
1218 - database: For sequences there is now also the stoptime available on the
1219 websites.
1220
1221 - database: Removed ManuallyChanged flag from sequence-info websites,
1222 as it is not needed anymore with the new sequence building algorithm.
1223
1224 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1225 Class for calculation of confidence intervals (upper limits).
1226 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1227 Please read the class instruction of TRolke for more information.
1228
1229 - general: The programs now return 0xfe if the requested resource file
1230 doesn't exist.
1231
1232 - general: Errors comming from root itself are now not output to
1233 stderr anymore but to our default (colored) log-stream.
1234
1235 - general: Changed the interface to TFormula such that now everything
1236 is parsed by TFormula, which should allow to use phrases even
1237 without paranthesis correctly parsed.
1238
1239 - callisto: replaced the AdHoc number of effective integration slices
1240 in the digital filter by an average of the correct number, averaged
1241 over all possible set of weights. This also gives correct numbers
1242 for the lo-gains which were totally wrong before.
1243
1244 - callisto: drastically reduced memory consumption by not storing
1245 all intermediate calibration results in memory anymore (we might
1246 write them into a file in the future)
1247
1248 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1249 debug plot displayed as a standard plot) use the context menu
1250 somewhere between the two upper plots, click on "DrawNicePlot"
1251 and enjoy the result. (It is the same context menu which contains
1252 the "DrawAll" option)
1253 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1254
1255
1256
1257 *** Version 0.10.2 (2006/10/15)
1258
1259 - general: changed the building of the sequence files such, that
1260 the source-/project name in case of wobble-sources is not the
1261 source/project of the first data run anymore but the new generalized
1262 wobble source/project
1263
1264 - general: Added some functions to MAstro to calculate sun and
1265 moon properties
1266
1267 - general: Added two new macros (starvisday.C and starvisyear.C)
1268 which allow to plot the visibility of several stars in one day
1269 or of one star along one year
1270
1271
1272
1273 *** Version 0.10.1 (2006/10/11)
1274
1275 - general: HTML logging output was distorted... fixed.
1276
1277 - general: Changed the writing of the sequencefiles such that only
1278 as many pedestal files as giving at least 1000 pedestal events which
1279 are nearby the first calibration run are used as pedestal runs
1280
1281 - sponde: In the calculation of the collection area(s) and the
1282 distribution for MOnte Carlo and estimated energy the error
1283 calculation was wrong because root didn't take the errors
1284 properly into account... fixed.
1285
1286
1287
1288 *** Version 0.10 (2006/10/10)
1289
1290 - general: all executables now check consistency of the root version
1291 installed with the root version used for compilation. The return
1292 code in this case is 255.
1293
1294 - general: The algorithm to build seqeunces has been redesigned
1295 completly. It is now more flexible in terms of a resource file
1296 resources/sequences.rc which can be used to partly overwrite
1297 the default algorithm and defined the important part of the
1298 algorithm. It also takes correctly into account several ways
1299 of taking wobble-data. Currently the new algorithm doesn't take
1300 the number of pedestal events anymore into account (so a sequence
1301 could have much less than 1000 pedestal events and data runs are
1302 no-more used instead)
1303
1304 - general: a lot of small changes to make the code compatible with
1305 root 5.12/00 and gcc 4.1
1306
1307 - general: Fixed some warnings thrown if more warnings are switched
1308 on in the compiler
1309
1310 - general: Added a function to MMath which returns the Median of
1311 the distribution abs(y[i]-median) but at 68:32 division instead
1312 of 50:50, which is somehow the median counterpart of the rms.
1313
1314 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1315 even if they are compressed with gzip (recommended compression
1316 is with "-1")
1317
1318 - showplot:
1319 + batch mode creation of image files now works with root 5.12/00
1320 + added support for writing bmp (though it never produces
1321 bmp which can be read by programs like xv or gimp)
1322 + added support for xml
1323 + added new option to start the display with a different size, by
1324 --display-width=nnn or --display-height=nnn
1325 + added options to define the canvas size when the display is started
1326 --canvas-width=nnn or --canvas-height=nnn
1327 the option can also be used for batch-mode conversion
1328 + added an option which automatically fits the display size to the
1329 desktop-size: --auto-size
1330
1331 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1332
1333 - merpp: allow the reports to have 1000ms due to a bug in the camera
1334 program.
1335
1336 - callisto: New swapped pixels have been found and corrected. For
1337 details see MRawRunHeader::FixAssignment()
1338
1339 - callisto: Callisto now raises an error if one of the input files could
1340 not be opened.
1341
1342 - callisto: In some rare cases it could happen that in the signal
1343 extraction of the digital filter the extractor returned nonsense
1344 results due a wrong initializion of a variable (this happens in
1345 cases in which the extracted signal is exactly zero or the
1346 digital filter couldn't slide because of a too small extraction
1347 window, which could happen in the lo-gain extraction)
1348
1349 - callisto: The lo-gains have been marked as valid in some cases
1350 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1351 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1352 smaller than the number of slices (fLoGainWindowSize) needed
1353 by the lo-gain extractor
1354
1355 - callisto: Updated absolute calibration constants (muon calibration)
1356
1357 - callisto: fixed a bug which caused the hi-gain saturation not
1358 to be handled properly in the spline (the position of the
1359 saturation was calculated incorrectly)
1360
1361 - callisto: fixed a bug which gave weird results if hi- _and_
1362 lo-gain could not be extracted properly. In some cases hi-
1363 and lo-gain have not been extracted at all and the random result
1364 got calibrated. In other cases the hi-gain was saturating and the
1365 lo-gain has not been extracted. For this a completly arbitraty
1366 scale factor was applied to the result from extracting the
1367 charge of the saturating hi-gain.
1368
1369 - callisto: improves handling of extracted signal if lo- and/or
1370 hi-gain could not be extracted properly. If no appropriate
1371 calibration of either the signal or the arrival time is possible
1372 the pixel is now markes as unsuitable instead of estimated.
1373
1374 - callisto: Fixed a problem in the spline extraction which gave
1375 weird results if the signal was extracted from the first (and
1376 highest) slice (as a workaround extraction from the first
1377 slice has been forbidden)
1378
1379 - callisto: Fixed a bug regarding the use of the QE which doesn't
1380 effect the result because the default is used anyhow.
1381 (The bug was there since 14/07/2005)
1382
1383 - callisto: Changed the default for fgLoGainStartShift to -2.4
1384
1385 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1386 factors to be always 10 for all pixels as soon as the first
1387 calibration update has happend.
1388
1389 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1390 was off by more than one slice (which gives wrong values for
1391 pixels which have saturated the hi-gain) This was a problem
1392 mainly for timing studies, not so much for the automatic standard
1393 analysis. Also the values for the Spline have been changed slightly:
1394 + Digital Filter from 1.70 to 0.95
1395 + Spline from 1.39 to 1.30
1396 The numbers were sorted out by an extensive test in the
1397 test-database.
1398
1399 - callisto: Removed the tab showing the average calibrated arrival
1400 time. It never gave useful information.
1401
1402 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1403 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1404 and both were extracted because the hi-gain was above the
1405 LoGainSwitch.
1406
1407 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1408 lo-gain pulse position (after application of LoGainOffset, which
1409 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1410 have saturated and both were extracted because the hi-gain was above
1411 the LoGainSwitch.
1412
1413 - callisto: After extensive tests a new threshold level for determination
1414 of the pulse position has been found at 50phe. This is due to the
1415 fact that for lower pulses the arrival time changes its average
1416 behaviour dramatically. It tends to the average of the extraction
1417 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1418
1419 - callisto: Added two more plots to the calibration part. The average
1420 extracted signal and the average extracted arrival time as
1421 extracted by the signal extractor (This can help debugging problems
1422 because it doesn't involve a fit)
1423
1424 - star: changed the fit for the effective on time such that initial
1425 values are calculated automatically now instead of using build
1426 in values. This makes the fit more indepedant of the underlaying
1427 rates. With a test of ~350 sequences in the test database it could
1428 be shown that the new fit gives the same result +/-1sek.
1429 The highest deviation was +5s the lowest -10s. You can now control
1430 the bahaviour with two resource values:
1431 MHEffectiveOnTime.FistBin: 3
1432 MHEffectiveOnTime.NumEvents: 12000
1433 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1434 from the resulting gamma candidates
1435
1436 - star: The Center histogram in MHHillas is now by default displayed
1437 with the colz draw-option
1438
1439 - ganymed: now produces valid error codes if failed
1440
1441 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1442 with the option "hadronness" instead of "area" or "both" if
1443 you want to use both cuts. The hadronness cut includes a fixed
1444 cut in hadronness (index 8) and a fixed cut in size (index 9).
1445
1446 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1447 the M3Long of the anti source to be not properly evaluated
1448 (actually is was evaluated as a unique random number) in case
1449 of optimization with anti-theta cut switched on. This might have
1450 lead to improper, but not necessarily wrong, optimization results.
1451
1452 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1453 how to use random forest
1454
1455 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1456 ganymed_onoff.rc. Seems to be unintentional that they were different.
1457
1458 - sponde: Since the introduction of the possibility to define a
1459 normalization energy instead of using the integral the default
1460 was not using the integral anymore but a normalization energy of
1461 1GeV. It is now the integral again.
1462
1463 - sponde: Fixed a problem in the weighting which did not allow
1464 a MC slope of -1.
1465
1466
1467
1468 *** Version 0.9.6 (2006/05/24)
1469
1470 - general: changed the binning of the azimuthal profile of the camera
1471 such that it is aligned with the 60deg boundaries.
1472
1473 - merpp: better handling of problems with the TH, TD part of the
1474 CC-REPORT for files older than 200507190 and 200412210
1475 respectively
1476
1477 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1478
1479 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1480
1481 - callisto: if an arrival time is extracted outside the fadc range is
1482 was set to the boundary before. Now a random number is assigned
1483 instead to avoid unfortunate coincidences of arrival times just
1484 by this arbitrary value.
1485
1486 - callisto: added a new option to callisto.rc which allows
1487 to set the maximum arrival time difference allowed for the
1488 badpixel algorithm to determin whether a pixels belongs to a shower:
1489 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1490
1491 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1492 to 0.9 as suggested by Stefan due to a recent study on the fraction
1493 of pixels surviving the image cleaning
1494
1495 - callisto: switched off error in case of "pulse is too much to the left"
1496
1497 - callisto: The extraction window is not adapted anymore. This means that
1498 the pulse is extracted from the full range. The draw-back is that the
1499 background (pedestal) will become slightly higher. Switching on/off
1500 the PulsePosCheck in the callisto.rc only effects filling the
1501 histograms.
1502 WARNING: If the pulse is too much to the left data is calibrated!
1503 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1504 in the database to make sure that your data is valid!
1505
1506 - star: Show also the number of stars correlated correctly by the
1507 starguider
1508
1509 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1510 than one off-source region in wobble-mode. To use it add the following to
1511 your ganymed_wobble.rc:
1512 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1513 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1514 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1515 + Cut1.ThetaCut: None
1516 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1517
1518 - ganymed: in the case the latest report is older than a default (currently
1519 one minute) and the current report will be skip the starguider
1520 correction and calibration will be reset. The maximum age can be
1521 setup from ganymed.rc by (minutes):
1522 MPointingDevCalc.MaxAge: 1.5
1523
1524 - ganymed: A first implementation showing all size-bins for the theta-sq
1525 resp. alpha-plots in a single tab automatically
1526
1527
1528
1529 *** Version 0.9.5.1 (2006/05/05)
1530
1531 - general: Added a new option "zdiff" to the Makefile which runs
1532 "cvs diff" as "make diff" would do, but with compression
1533
1534 - general: accelerated MTFillMatrix (used for eample in all training
1535 and optimization macros) by skipping some obsolete calles in the
1536 eventloop the first and second loop could be accelerated by ~20%
1537
1538 - general: Added a missing feature in the MFilterList class which
1539 prevented MFEnergySlope from working correctly in trainenergy.C
1540
1541 - general: Accelerated the random forest training and usage a bit
1542
1543 - merpp: Adapted to new raw data file format version 6
1544
1545 - merpp: fixed a problem with reading the starguider reports
1546 after 6.3.2006
1547
1548 - callisto: At some times six pixels had to be exchanged manually in the
1549 data. If the pixels to be swaped are both not found, an error was raised
1550 and calibration was stopped. Now it is assumed they are intentially not
1551 mapped and the Error has been changed to a Warning.
1552
1553 - star: Added new image cleaning based on the arrival time of the shower.
1554 The new cleaning can be accessed using the parameter "Time" instead of
1555 the the old one (like "Absolute) in the star.rc-file.
1556 Recommended parameters:
1557 + MImgCleanStd.CleanLevel1: 8.2
1558 + MImgCleanStd.CleanLevel2: 5
1559 + MImgCleanStd.CleanRings: 2
1560 + MImgCleanStd.KeepSinglePixels: No
1561
1562 - star: Simplified the calculation of the effective on time. By letting
1563 the fit start in the third bin the result should become more stable.
1564 The fit quality is now ignored for the theta-plot which is not used
1565 in the analysis later. Still better pre-cut which, for example,
1566 remove events triggered by car-light (rate changing on a short
1567 time-scale) are missing.
1568
1569 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1570 for optimization (kWeakSource) which is suggested by the Berlin
1571 people for weak sources.
1572
1573 - macros: plotdb.C:
1574 + if no dataset and no time-interval is given only sequences with
1575 an effective on-time above five minutes are plotted anymore
1576 + added a new tab "RelTime" displaying the relative on-time
1577 (effective on-time divided by the observation time)
1578
1579 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1580 the optimization became a lot faster
1581
1582 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1583 To display them just delete the pads displayed on top.
1584
1585 - ganymed: fixed a bug which could cause strange behaviour in wobble
1586 mode if no starguider information was available due to an incorrect
1587 initialization of the starguider calibration
1588
1589 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1590 be changed from within the plot. It can also be setup from the
1591 resource file using:
1592 + MHDisp.fScaleMin: 0.325
1593 + MHDisp.fScaleMax: 0.475
1594
1595 - ganymed, showplot: Fixed a problem with the fit to the off-data
1596 (HistOff) which could cause a time lag or an inifinite loop.
1597 The bug did not effect the results at all.
1598
1599 - sponde: Added a new tab showing the effective collection area after
1600 trigger (including the software trigger)
1601
1602 - sponde: MMcSpectrumWeight has a new option which allows to define
1603 the scaling factor not by the integral of the events but at
1604 a defined energy:
1605 e.g. MMcSpectrumWeight.NormEnergy: 200
1606
1607 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1608 eventloops the loop could be accelerated by ~20%
1609
1610
1611
1612 *** Version 0.9.5 (2006/03/13)
1613
1614 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1615 and added the standard Disp-parametrization
1616
1617 - macros: added a new macro datacenter/macros/plotstat.C allowing
1618 to plot statistics about the data processing
1619
1620 - macros: added a new macro to plot the muon correction coefficients
1621 versus period (macros/plot/mucal.C)
1622
1623 - showplot: path inflation for ganymed files was broken
1624
1625 - callisto: Fixed an important bug. When the number of saturating pixels
1626 were calculated the bad pixel information already available from the
1627 calibration was ignored. This yields wrong values in case pixels
1628 are broken and saturate all the time or randomly.
1629
1630 - callisto: Updated Muon calibration constants. Spline data now also uses
1631 different values for different periods
1632
1633 - star: The time-evolution shown in the effective on-time plot now displays
1634 the axis range (if there are no holes it should be similar to the
1635 effective on-time)
1636
1637 - star: Added two new image parameters:
1638 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1639 the three pixels next to the center of gravity and the size
1640 + MNewImagePar.fConcCore: The ratio of the signals of all
1641 pixels inside or touching the ellipse and the size
1642
1643 - ganymed: now stops in requested source isn't found in catalog file
1644
1645 - ganymed: Many improvements to the phi-plot in wobble mode:
1646 + with a template the ideal background is displayed
1647 + a possible camera inhomogeneity is taken into account
1648 + the anti theta cut is better supported
1649 + the phi cut is automatically calculated from the theta cut
1650 See the examples in ganymed_wobble.rc for more details.
1651
1652 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1653 times the bin-width instead of the absolute energy
1654
1655 - ganymed: New cuts for on/off and wobble mode
1656
1657 - ganymed: The smearing of the False Source plot has been increased
1658 to 0.06
1659
1660 - ganymed: The starguider calibration can now be changed from the
1661 resource file.
1662 See the examples in ganymed*.rc for more details.
1663
1664 - ganymed: added a new option for on-/off-observations
1665 MJCut.RandomSourcePosition
1666 If switched on the distribution of observation time of the source
1667 position in the camera is calculated from the on-data and randomly
1668 applied with this distrbution to the off-data.
1669
1670 - ganymed: by skipping some obsolete calles in the eventloop the
1671 first and second loop could be accelerated by ~20%
1672
1673 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1674 position in the off-data randomly according to its distribution in the
1675 on-data.
1676
1677
1678
1679 *** Version 0.9.4.3 (2006/02/13)
1680
1681 - general: Fixed a bug in most of the programs which prevented the
1682 compile date in the startup message to be displayed
1683
1684 - general: Simplified program calls. The following abbreviations
1685 are now possible:
1686 showlog callisto 55599
1687 showplot signal 55599
1688 star 55599
1689 callisto 55999
1690 ganymed 2
1691 In this cases the corrsponding root-, log-, sequence- or dataset-
1692 filename is automatically compiled using the default datacenter
1693 paths ("/magic/*")
1694
1695 - general: Fixed a long outstanding bug which made axis tick marks
1696 disappear if MDataFormula was used (eg. abs(x))
1697
1698 - general: Updated MMath with new functions to calculate the results of
1699 a exponential, logarithmic and powerlaw fits analytically.
1700
1701 - general: Updated some macros with comments:
1702 + macros/optim/optimdisp.C
1703 + macros/optim/optimenergy.C
1704 + macros/optim/optimwobble.C:
1705
1706 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1707 files) now allows adding a pre-cut like in the optimization. E.g. this
1708 is useful to perform g/h-separation cuts before training the random
1709 forest.
1710
1711 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1712 correctly assigned in the raw data assignement table. A fix to correct
1713 the assignment tabel have been implemented.
1714
1715 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1716 by 90, 180 and 270 deg.
1717
1718 - general: the macro plotdb.C now allows to highlight sequences belonging
1719 to a datset. For more details see the descritions in the macro.
1720
1721 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1722 of the display, it gave wrong results espacially for big sizes.
1723 Now the embedded canvas should always have a ratio width/height=3/2.
1724 The "Size" options have been updated with values fitting the 3/2
1725 size ratio.
1726
1727 - RanForest:
1728 + Updated the random forest classes to support also the
1729 regression method implemented by Thomas H.
1730 + added new tutorial macro how to train the random forest
1731 for energy estimation (macros/optim/rfenergyest.C)
1732 + new classes to train the random forest (still in development)
1733 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1734 + new tutorial macros for random forest training in macros/train
1735 trainenergy.C, traindisp.C, trainseparation.C
1736
1737 - mars: now allows to setup a cut in the resource file mars.rc to choose
1738 the events to be displayed, eg:
1739 Cut.Condition: {0} && {1}
1740 Cut.0: MHillas.fSize>100
1741 Cut.1: MHillas.fSize<900
1742
1743 - merpp: Made aware of the new .rep format 200510250. This includes
1744 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1745 the discriminator thresholds (MCameraTD) and the disciminator
1746 delays (MCameraTD). All of them come with the CC report and are therefor
1747 written to the CC tree.
1748
1749 - callisto: fixed a bug in the calculation of the arrival times in
1750 the Digital Filter. They were all shifted by the same amount
1751 fHiGainFirst. This caused an offset in the order of the position of
1752 the left border of the extraction window in the times calculated
1753 from high-gain and from low-gain. The bug effected only the absolute
1754 arrival times. The bug was there since 30.1.2005.
1755
1756 - callisto: Changed the ExtractionWindow for the pulse position check
1757 such that the camera inhomogeneity becomes as less as possible and
1758 comparable to the pulso position check switched off. More details
1759 on the study will be given at our result web-page.
1760
1761 - ganymed: ganymed.rc, ganymed_onoff.rc:
1762 changed to new cuts trained with 1ES1218 and Crab-data
1763 for maximum sigma*log10(excess)
1764
1765 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1766 a new option was implemented to estimate Disp (CalcDisp)
1767
1768 - ganymed: Implemented two new options which allow
1769 to overwrite the default path to search for the sequence files
1770 --ins=/magic/sequences
1771 and where to search for the image data
1772 --ind=/magic/data/star
1773
1774 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1775 dx/dy from the resource file by
1776 MSrcPosCorrect.Dx
1777 MSrcPosCorrect.Dy
1778
1779 - ganymed: fixed reading the source catalog. Only as many chars
1780 as the requested source name had were compared (If a source
1781 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1782 were requested it could happen that the coordinates of
1783 "1ES1218" were read) The source coordinates are now printed
1784 in addition to its name to the logging output.
1785
1786 - ganymed: changed the background fit in the case of a ThetaSq function
1787 from a polynomial to a exponential, this should give a big improvement
1788 for on-only analysis'
1789
1790 - ganymed/sponde: Calculation of the error of single size-/energy-
1791 bins now uses Li/Ma (5) instead of LiMa (17)
1792
1793 - sponde: Added a plot E^2*dN/dE
1794
1795 - sponde: The energy estimator plot should now show values like
1796 they are commonly used.
1797
1798 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1799 (a powerlaw with cutoff didn't work before)
1800
1801
1802
1803 *** Version 0.9.4.2 (2005/10/01)
1804
1805 - general: added new tutorial macro macros/tutorials/threshold.C:
1806 how to calculate the threshold
1807
1808 - general: added a new game. Start it from the interpreter with
1809 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1810 and MagicReversi)
1811
1812 - general: neighbor pixels in MGeoms are now sorted clockwise
1813
1814 - merpp: made aware of new format 20050829-0
1815
1816 - callisto: New scale factors from muon analysis, stored in new
1817 resource file resources/calibration.rc
1818
1819 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1820 the eventloop if something went wrong. This is necessary for the
1821 automatic processing
1822
1823 - callisto: Implemented a new treatment for the time information
1824 developed by S.Ruegamer, this should give much better response than
1825 the old very primitive algorithm. This is especially important
1826 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1827 treatment was buggy! As neighbor pixels to interpolate the
1828 arrival times always the pixels 0 to 5 were taken)
1829
1830 - callisto: In addition to the new treatment of arrival times the
1831 decision of the treatment whether a pixel contains shower
1832 information or not is used to improve the signal interpolation
1833 further. Previously interpolated pixels showed a non-zero signal
1834 do the peak searching signal extractors. Having a signal pixel
1835 beside raised the signal above the cleaning level. Thus the
1836 pixel survived cleaning to often but with a too low mean signal.
1837 By replacing empty pixels with a gaus (mean and rms from the
1838 corresponding Area entries in MPedPhotCam) this effect can
1839 be supressed.
1840
1841 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1842 got lost when the events were stored by the calibration... fixed.
1843 (This was no problem for normal image cleaning because the pixel
1844 content was artificially set to 0 not surviving standard cleaning
1845 algorithm)
1846
1847 - callisto: Fixed a bug which caused the random and peak-search pedestal
1848 extracted with an extractor to be exchanged for the first (roughly)
1849 500 events (*Extractor and *ExtractorRndm).
1850 (They were simply exchanged in callisto.cc) This bug might have been
1851 introduced in Mars 0.9.4 when the order of calculation of the two
1852 types of pedestal in callisto got exchanged. The bug only effects
1853 the first seconds of data of each sequence.
1854
1855 - star: Taking the arrival time of Muons into account the calculation
1856 of the parameters could be made independant of the noise
1857 (pedestal rms). The dependance was due to the bias of the peak search
1858 extractor. Now only a ZA dependamcy is left which is not yet fully
1859 understood.
1860
1861 - ganymed: The sequences were still not sorted correctly in any case,
1862 because they were sorted by the full qualified path name. Now they
1863 are sorted by their sequence number.
1864
1865 - ganymed: new values for the spark-event-cut
1866
1867 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1868
1869
1870
1871 *** Version 0.9.4.1 (2005/08/18)
1872
1873 - callisto: fixed some problems with the calibration in case of
1874 inteleaved events. Therefor the final and some intermediate
1875 fits are skipped which would take place on partly filled #
1876 histograms and gave wrong results or failed completely.
1877
1878 - callisto: If the intermediate finalization of the histograms
1879 calculating the mean charge of the calibration signal fails
1880 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1881
1882 - ganymed: Fixed some bugs which caused problems in On-only mode.
1883 Still the false source plot doesn't give reasonable results.
1884
1885
1886
1887 *** Version 0.9.4 (2005/08/05)
1888
1889 - general: Fixed the ZA binning. It did not correctly fit the
1890 MC binning
1891
1892 - general: Added a class to correct for the missfocussing in
1893 April (MSrcPosCorrect)
1894
1895 - general: Random Forest energy estimator should now work properly
1896
1897 - general: MHCamera now displays the profiles in deg instead of mm
1898
1899 - general: MH::SetPalette offers a lot of new palettes
1900
1901 - general: MHillas - the case of CorrXY==0 is now handled properly
1902
1903 - general: implemented the possibility to change the line and
1904 marker style of a sky-grid drawn by MAstroCatalog
1905
1906 - general: Runs in sequences and datasets are now automatically
1907 ordered (it is assumed that the order of their filenames correctly
1908 represents the order of observations) to ensure correct reading
1909 of the subsystem data
1910
1911 - general: Runs cannot be added to a sequence twice anymore. Also
1912 Sequences cannot be added twice anymore to a dataset.
1913
1914 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1915 It gave wrong results by 1./2pi
1916
1917 - showplot: got a new option to start a root interpreter, too
1918
1919 - mars: now displays a rough estimate of Disp and the third moment
1920
1921 - mars: now displays the event time MTime if available
1922
1923 - mars: show muon parameters graphically
1924
1925 - mars: now the file to open can be given as commandline
1926 argument
1927
1928 - merpp: Added support for new arehucas version >= 200507190
1929 implementing values for three temperature sensors in the
1930 counting house (MCameraAUX) and the name of the HV settings file
1931 (MCameraHV).
1932
1933 - merrp: Also fixed some problems with wrong versions numbers stated
1934 by arehucas and implemented some fixed for old versions (<200407070)
1935
1936 - callisto: MCalibrationHiLoCam can now be printed from its context
1937 menu, eg in the TBrowser
1938
1939 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1940 - 1.39 (MExtractTimeAndChargeSpline)
1941 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1942 This is important mainly for timing studies.
1943
1944 - callisto: Changed limits in MHCalibrationChargeCalc from
1945 - -100.125 to -98 (fgChargeHiGainFirst)
1946 - 1899.875 to 1902. (fgChargeHiGainLast)
1947 - -100.25 to -99 (fgChargeLoGainFirst)
1948 - 899.75 to 901. (fgChargeLoGainLast)
1949 Introduced new limits:
1950 - fgNumLoGainBlackoutLimit: 0.05
1951 - fgLoGainBlackoutLimit: 3.5
1952 - fgLoGainPickupLimit: 3.5
1953
1954 - callisto: The handling of automatic weights for the digital filter
1955 has been improved. There are now new calibration weights special
1956 for Monte Carlo calibrations.
1957
1958 - callisto: Updated Muon scale with latest results (1% difference
1959 for most data, 5% for Mar/Apr'05)
1960
1961 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1962 was saturated and the blackout-events in the low-gain exceed the
1963 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1964 This excludes those pixels which have a saturating high-gain
1965 channel, but the low-gain switch does not switch often enough
1966 to make the distribution reliable.
1967
1968 - callisto: fix a bug counting the number of saturated events. Up to now,
1969 the number of saturated slices was counted (which is one for a not too
1970 high number), but for some (pathological) pixels, many more slices
1971 saturated and produced wrong limits.
1972
1973 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1974 + MCalibrationRelTimeCam.CheckFitResults: Yes
1975 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1976 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1977 + MCalibrationRelTimeCam.CheckOscillations: Yes
1978
1979 - callisto: introduce max. number of events for intercalibration,
1980 the rest gets skipped. Default: 4096
1981 The calibration causes too many un-reliable pixels if more
1982 than about 5000 events are treated (@500 Hz) because of the
1983 mode hopping of the VCSels. However, in the past, some
1984 calibration runs have been taken (erroneously) with more
1985 than 5000 events, especially the intensity scans where
1986 a good precision is needed.
1987
1988 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1989 photo-electrons for the spline extractor by 1-2% (correctly).
1990
1991 - callisto: The intercalibration is now done using a full f-factor
1992 method instead of a simple update. This makes things slower but
1993 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1994 changes.
1995
1996 - callisto: MPedestalY3 now uses the same extraction range as the data
1997 as calculated by MPedestalY2
1998
1999 - callisto: A check of the fraction of allowed unsuitable (10%) and
2000 unreliable (30%) pixels has been addded when the conversion is
2001 calculated from interleaved events
2002
2003 - star: fixed a bug which caused MEffectiveOnTime containers not to
2004 be written. In the worst case they were skipped almost all, in the
2005 best case they were all ok. It depends on how often the new value
2006 was assigned just with an event which was skipped later by another
2007 task
2008
2009 - star: new histograms MHPointing and MHRate
2010
2011 - star: New tab (Currents) displaying the time evolution of the mean
2012 DC currents
2013
2014 - star: New tab (MeanRms) displaying the time volution of the mean
2015 Pedestal Rms
2016
2017 - star: Output now contains MReportStarguider
2018
2019 - star: Improved muon analysis. Due to the absense of a constant
2020 for the gaus fit for arc width and the fact that the arcwidth
2021 plot was a histogram instead of a profile the resulting psf
2022 became pedestal rms dependant
2023
2024 - ganymed: added new plot (MHPhi) for wobble mode as described in
2025 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2026
2027 - ganymed: corrects now (correctly?) for the misspointing in
2028 May/April 05
2029
2030 - ganymed: Two new default templates for ganymed.rc are avilable:
2031 ganymed_onoff.rc and ganymed_wobble.rc
2032
2033 - ganymed: The first version of MFMagicCuts has been released
2034
2035 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2036
2037 - ganymed, sponde: There are two new options to determin the number
2038 of bins for the signal region (NumBinsSignal) and the number of
2039 total bins (NumBinsTotal) in the MHThetaSq histogram
2040
2041 - ganymed: optimized palettes for MHDisp
2042
2043 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2044 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2045 sqrt(2) to large
2046
2047 - ganymed: The false source plot (MHDisp) is now based on Disp
2048 and a background model determined in the first loop is
2049 subtracted
2050
2051 - ganymed: MFMagicCuts are now available in the cvs. The correct
2052 solution for the disp ambiguity problem is now calculated using
2053 the third moment. The third moment cut therefor is skipped.
2054
2055 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2056 already determined by the third moment along the major axis and
2057 so its actual sign is aligned along the major axis of the shower.
2058
2059 - ganymed: If starguider data is available it is taken into account
2060 when calculating the source position. This is especially important
2061 for wobble data at high zenith angles and culmination data.
2062
2063 - ganymed: If available the starguider data is taken into account as
2064 good as it is possible without a starguider calibration. To switch
2065 it off add
2066 MPointingDevCalc.MaxAbsDev: -1
2067 to your ganymed.rc
2068
2069 - sponde: the zenith angle distribution is now weighted instead of
2070 choosen by default. This gurantees higher statistics in the highest
2071 and lowest energy bins. To switch this behaviour off use...
2072
2073 - sponde: now automatically displays the energy threshold
2074
2075
2076
2077 *** Version 0.9.3 (2005/06/03)
2078
2079 - general: MMcEvt now derived from MMcEvtBasic which should
2080 have no influence on compatibility with older camera files
2081
2082 - general: Implemented a new option to MReadReports which allows
2083 to force reading of the first event of some trees (eg. Drive-tree)
2084 before any other tree.
2085
2086 - general: Made a fix to MPointingPosCalc which assumes that the
2087 run-type is real-data if Process is called before ReInit, such
2088 that also the very first Drive-events in a run are treated
2089 correctly.
2090
2091 - shoplot now displays the filename in the title bar of the window
2092
2093 - merpp: new options: --auto-time-start --auto-time-stop which
2094 allow to cut updating with slow-control at the start- or
2095 (previousle --auto-time only allowed: and) stop-time of
2096 the run stored in the runheader.
2097
2098 - callisto: changed default of fgFallTimeHiGain in
2099 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2100 already set as default in callisto_Dec04Jan05.rc
2101
2102 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2103 now changes the filename for new weights automatically for
2104 cosmics, MC and for different calibration colors.
2105
2106 - callisto: a problem with the order of some code cause the
2107 name of the weights file in MPedestalY2 to be ignored.
2108 Wrongly the calibration_UV weights were used instead
2109 of the cosmics weights set in callisto.rc.
2110
2111 - callisto: should allow ct1 pulser data when the color is
2112 explicitly set also for pretty new runs
2113
2114 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2115 to introduce an additional scale factor (should be around 1)
2116 to adapt for slight deviations in different extractors from
2117 the MC calibration. For MC calibrations the scale factor
2118 is fixed to 1
2119
2120 - callisto: MFCosmics should handle very high signals a bit
2121 more accurate now
2122
2123 - callisto: when calculating the mean pedestal rms for different
2124 pixel sizes or sectors also kUnsuitableEvt is now taken into
2125 account - not only kUnsuitableRun
2126
2127 - callisto: '-raw' option is now the default
2128
2129 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2130 This has the advantage that mean values in the calibration (eg
2131 arrival times) are calculated more accuratly.
2132
2133 - callisto: In the resource file callisto_Dec04Jan05.rc
2134 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2135
2136 - callisto: new Hi-/Lo-Gain intercalibration constants
2137 hilocalib_sp1.root and hilocalib_sp1_mc.root
2138
2139 - callisto: changed default for MJPedestalY2.MaxEvents
2140 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2141
2142 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2143 has changed from 9.0 to 6.0. This is necessary to exclude two very
2144 ringing pixels in September which - when kept - destroy the image
2145 cleaning around them (Markus G.)
2146
2147 - callisto: (!) The Muon analysis of all data taken so far has
2148 suggested that different extractors give slightly different
2149 absolute results after calibration, due to there different
2150 handling of the calibration- and cosmics pulse shape. Although
2151 the over all calibration seems to be a bit to pesimistic (or
2152 the MC seems to be a little bit - 3-5% - too much attenuated).
2153 There for correction factors have been introduced which correct
2154 the calibration constants by
2155 0.956937799 for Digital Filter (callisto.rc)
2156 and
2157 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2158 calibration. The main advantage is, that both data types can
2159 be easily analysed together and compared to the same MC sample.
2160 The factors are choosen such, that the reference is now a
2161 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2162
2163 - star: fixed a bug which caused the first bin of the histograms
2164 vs time to disapear in PostProcess. This gave wrong results
2165 on the screen. The output and all following programs not
2166 directly accessing the histograms haven't been affected
2167
2168 - star, ganymed: Made sure that always the first Drive-tree event
2169 is read and Processed before the first data event was read.
2170
2171 - ganymed: implemented the possibility to replace the standard
2172 false source plot with a different one. For example: If
2173 you want to use a Disp based FS plot use the resource:
2174 NameHistFS: MHDisp
2175 For details about the requirements of these plots look
2176 at the corresponding classes
2177
2178 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2179 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2180 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2181 case MAlphaFitter is setup correctly. For On-Only optimization
2182 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2183 RunOn() instead of Run(). For energy estimation MJOptimize
2184 has been replaced by MJOptimizeEnergy
2185
2186 - sponde: The input MC spectrum can now be weighted to fake a
2187 different spectrum. This is done via MMcSpectrumWeight. For
2188 more details see the class description and sponde.rc
2189
2190 - sponde: The paremeter comparsion plots are not scaled by
2191 their entries anymore. Instead the MC plot is scaled by using
2192 the result spectrum of the analysis. If the input MC spectrum
2193 and the result spectrum has different slopes the absolut
2194 normalization is normally wrong.
2195
2196
2197
2198 *** Version 0.9.2 (2005/05/20)
2199
2200 - general: Changed the default paths for calibrated data and image
2201 files. (The implemented access to these files doesn't yet exist)
2202
2203 - general: support for MRunIter has been removed from the job classes
2204 (use the setter functions of MSeqeunce instead)
2205
2206 - general: ProcessFile has been renamed to Process in all job classes,
2207 because ProcessFile is missleading
2208
2209 - general: The storage of the palette in MHCamera is now possible
2210
2211 - general: new bits describing unsuitable and unreliable pixels have
2212 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2213 kDeadPedestalRms, kFluctuatingArrivalTimes
2214
2215 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2216 versions newer than V200404070
2217
2218 - general: support for cc file versions newer than V200504130. Added
2219 support for active loads (MCameraActiveLoad) and central pixel
2220 (MCameraCentralPixel)
2221
2222 - general: added new histograms for image parameters versus size
2223 (MHVsSize)
2224
2225 - general: The eventloop now automatically calls PrintStatistics
2226
2227 - Status Display: Improved support for printing:
2228 + A default can now be set in .rootrc (for more details see
2229 MStatusDisplay::PrintPS)
2230 + A print dialog is opened so that printer and command line
2231 can be canged
2232
2233 - showlog: improved such that it handles different verbosity levels
2234 more accurate now. This mean you can suppress output when
2235 using showlog.
2236
2237 - showplot: improved
2238 + The new graphics formats have been implemented
2239 (pdf, svg, png, jpg and xpm)
2240 + Implemented an interface for printing. Because you can change
2241 the printing command from the command line you can use all
2242 the nice postscript tool. To print a booklet for example call:
2243 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2244 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2245 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2246
2247 - callisto: fixed a bug in the recognition of the calibration bit
2248 pattern. Concerns only intensity calibration. (The strength of the
2249 intensity has been updated in some cases)
2250
2251 - callisto: add a filter against PIN Diode events when running over
2252 calibration runs since some of the recent calibration runs have
2253 been taken with Pin Diode.
2254
2255 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2256 39943, 44833 in the calibration (MCalibColorSet)
2257
2258 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2259 been set to 1e-18 in callisto_Dec04_Jan05.rc
2260
2261 - callisto: in callisto_Dec04Jan05.rc: set value for
2262 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2263 statistics for the calculation of the mean pulse time
2264 of the cosmisc
2265
2266 - callisto: the charge limit in the calibration has been raised
2267 from 2.5 to 4.5
2268
2269 - callisto: new setup read from callisto.rc
2270 + MCalibCalcFromPast.fNumEventsDump
2271 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2272 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2273
2274 - callisto: MExtractTimeAndChargeSpline extractor:
2275 + The integration ranges were shifted by 0.2 FADC slices to the right.
2276 + unreliable handling of floating point values caused different
2277 results on different platform or with different compiler options:
2278 The new algorithm is numerically exact and more accurate because
2279 it doesn't calculate the integration position by multiple times
2280 adding the step-size (which results in numerical uncertanties
2281 exspecially if multiplied with large numbers)
2282 + A lot of fixes have been introduced which effects integrating the
2283 spline at the edges of the valid range. In this case any memory
2284 was randomly accessed. This behaviour can be tested replacing
2285 all MArrayF by TArrayF which perform a range check (but of course
2286 they are a lot slower)
2287 ! No result obtained with the Spline before can be trusted! Due to
2288 random memory access it might by completely random!
2289
2290 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2291 + extraction range in the high gain to 4.
2292 + weights file to cosmics_weights46.dat
2293
2294 - callisto:
2295 + introduce the check for fluctuating arrival times.
2296 + set charge limit to from 2.5 to 4.5
2297 + introduce asymmetric exclusion due to "deviating number of phes":
2298 Default: -9.0 +4.5
2299 + make deviating number of phes unsuitable (see David's findings).
2300
2301 - callisto: fixed the display of unsuitable pixels. The old change
2302 to a real profile in MHCamera broke it.
2303
2304 - callisto: The cosmics filter is used in MJCalibration now
2305 independant of the pulser color (formaly it was used only for
2306 CT1-pulser data). The threshold of number of max empty pixels
2307 has been raised from 2% to 5% in MJCalibration. The maximum
2308 fraction of rejected event is 50% otherwise the calibration has
2309 failed. The filter now ignores unsuitable pixels.
2310 Setup the filter from callisto.rc using "ContCosmics"
2311 (see MFCosmics::ReadEnv)
2312
2313 - callisto: changed default for fgOffsetFromLogain back
2314 from -2.8 to -1.8 in digital filter.
2315
2316 - callisto: for the common extractors
2317 + MExtractFixedWindow
2318 * MExtractTimeAndChargeSlidingWindow
2319 * MExtractTimeAndChargeSpline
2320 * MExtractTimeAndChargeDigitalFilter
2321 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2322 and fResolutionPerPheLoGain
2323
2324 - callisto: Updated the hi-/lo-gain intercalibration constants
2325 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2326 hilocalib_df6.root
2327
2328 - callisto: The default lo-gain extraction window for the
2329 MExtractTimeAndChargeSlidingWindow extractor has been increased
2330 from 6 to 8 to take the stretch of the pusle into account
2331
2332 - callisto (!!!): fixed an important bug in the setting of the
2333 incoming pedestal pointer to the signal extractor extracting
2334 pedestals. This bug caused the pedestals not to be subtracted
2335 correctly in the calibration afterwards. The effect was about 10%
2336 too high conversion factors for the digital filter and the spline
2337 and more than 40% for the sliding window.
2338 The bug existed since end of February! (Markus G.)
2339
2340 - star: added muon support to star. A new tab "MHMuonPar" is
2341 displayed. The lower right plot is an estimate of the point spread
2342 function. A reference value is displayed. To get the real PSF
2343 you must compare with MC. The setup for the muon analysis
2344 is done in star.rc. More informations can be found in
2345 MHSingleMuon and MHCalibParCalc
2346
2347 - star: The weather data is now displayed in star
2348
2349 - star: MEventRateCalc handles the calculation of the event rate more
2350 accurate now in case of the start of a new run inside a sequence
2351
2352 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2353 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2354 changed only minimally
2355
2356 - ganymed: (MJCut and MJOptimize) now displayes the number of
2357 excess events versus size. The energy estimation is done in
2358 MJSpectrum (sponde)
2359
2360 - ganymed: got support for using other variables than Alpha, eg. Theta.
2361 Therefor you need a class deriving from MHAlpha which supports
2362 this variable (one is already existing: MHTheta, which is now the
2363 default in ganymed). It is setup through ganymed.rc
2364
2365 - added a full featured spectrum program (sponde) which reads
2366 ganymed output and monte carlos and compiles a spectrum
2367
2368
2369
2370 *** Version 0.9.1 (2005/04/14)
2371
2372 - Fix bug on the arrival time reconstruction when using Digital
2373 Filter (in some marginal cases (10%) times were reconstructed shifted
2374 by 0.2 slices)
2375
2376 - all executables now return 2 where in previous versions -1 has
2377 been returned (gave problems with shell-scripts)
2378
2379 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2380 also done with a intercalibration input file
2381
2382 - a bug in the time fine adjustment of the digital filter has been fixed
2383
2384 - a lot of small fixes to calling TPad::Divide with a margin==0
2385
2386 - MStatusDisplay now shows the memory usage
2387
2388 - added a memory leak statistic after the eventloop
2389
2390 - MHadronness replaced by MParameterD
2391
2392 - MEnergyEst replaced by MParameterD
2393
2394 - wobble mode can now be switched on from the data-set
2395
2396 - switched on bad pixel detection for a pedestal level
2397 which is more than 5 times the variance
2398
2399 - Fixed default paths to be correct for the new data center
2400
2401 - Fixed handling of drive data. The pointing position in now
2402 copied to MPointingPos inside star for real and MC events
2403
2404 - made sure, that the sequences in a dataset are sorted by
2405 their number to ensure the correct synchronization
2406
2407 - added all resource files necessary to handle spline extraction
2408 of signal for the late 2004 and the early 2005 data
2409
2410 - update the reference lines for the december data
2411
2412 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2413 This is important for the Dec. and Jan. data where the calibration
2414 pulse position changes much.
2415
2416 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2417 filter. This corrects only an defective extraction of the MC at
2418 low-gain signals lower than 90 phes.
2419
2420 - fixed some slowdown in calibrating data with interleaved events from
2421 Jan and Dec. As a workaround made the pretty palette the default.
2422 The inverse Deep Blue Sea has a bug which slows down long calibration
2423 runs a lot.
2424
2425 - implemented new values from new starguider report as defined
2426 in TDAS00-07 V7.1 (eg SkyBrighness)
2427
2428 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2429 in starguider report (If you merpp the same reports with this version
2430 you'll get the correct units (arcmin) but a different result
2431 than with old versions (wrong units))
2432
2433 - Now the status display can also write PNG, JPEG and XPM (other file
2434 formats are still unsupported by root)
2435
2436 - added a lot of scripts and macros in directory datacenter used
2437 for automatic processing
2438
2439
2440
2441 *** Version 0.9 (2005/03/23)
2442
2443 - Calibration is now done autmatically into photo-electrons like
2444 decided by the Collaboration Board
2445
2446 - Reference lines in the display can be read from resource file
2447
2448 - Interlaced calibration events can be handled by callisto
2449
2450 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2451 and applied in callisto.
2452
2453 - class MJCalibTest can be called by callisto
2454
2455 - callisto can now run with three data types: rawdata, rootdata, MC
2456
2457 - added two classes mreport/MReportStarguider.cc and
2458 mreport/MReportStarguider.h for implementing starguider-data
2459
2460 - the output of merpp-update now contains starguider information:
2461 MReportStarguider and MTimeStarguider
2462
2463 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2464 values were lower than they should. This was more visible for high
2465 energy (Size) events.
2466
2467 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2468
2469 - added a new loop to callisto to support the correct extraction of
2470 the pedestal and pedestal rms through the signal extractor
2471
2472 - added class to perform fourier tranformation of a hexagonal structure
2473 (MHexagonalFT)
2474
2475 - added class to perform fourier tranformation of a hexagonal structure
2476 in a tasklist (MHexagonalFTCalc) example: hft.C
2477
2478 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2479 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2480 small pixels, example: extendcam.C
2481
2482 - added possibility to write data to memory (TTree) using MWriteRootFile
2483
2484 - added possibility to read a TTree stored only in memory by MReadTree
2485
2486 - new classes to deal with the interleaved calibration events:
2487 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2488
2489 - implemented filters to callisto to skip calibration events
2490
2491 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2492 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2493 the slices by statistics
2494 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2495 signal extractor without randomization
2496 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2497 with the signal extractor with randomization (extraction window is
2498 randomly fixed)
2499 The three kind of pedestal is not yet implemented (for speed reasons) as
2500 long as nobody really needs it:
2501 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2502 extracted with the signal extractor with randomization
2503
2504 - callisto now finds the pulse position in the data automatically
2505
2506 - implemented data reduction in calibrated data by reducing the precision
2507 of the stored floating point values (pedestal, rms and signal) to
2508 roughly 0.5%
2509
2510 - fixed showplot to make file format conversion (eg. converting a
2511 status display stored in a root file into a postscript file) in
2512 batch mode possible:
2513 showplot -b --save-as-ps[=outfile.ps] infile.root
2514
2515 - Allow class names as part of filter rules, eg
2516 (MFSupercuts) && (MHillas.fSize>100)
2517
2518 - fixed a lot of stuff to allow all programs to process MonteCarlo
2519 camera files.
2520
2521 - enhanced possibility to debug reading of resource file
2522
2523 - MDataChain should handle priorities of operator more
2524 accurate now
2525
2526 - completely revised the container in which the signal is stored
2527 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2528 * the new implementation is faster and
2529 * needs less storage space
2530
2531 - FIRST version which can process Monte Carlos through the
2532 whole chain of programs (callisto, star, etc)
2533
2534 - implemented new image parameters for the border length of
2535 the shower image (MNewImagePar2)
2536
2537 - implemented wobble-mode in ganymed
2538
2539 - new class (MJOptimize) taking care of all optimization processes
2540
2541
2542
2543 *** Version 0.8.6 (2004/10/05)
2544
2545 - New combined signal and time extractor
2546 MExtractTimeAndChargeDigitalFilter
2547
2548 - The Report for the trigger section in the CC run summary has been
2549 updated, and now the IPRs (Individual Pixel Rates) are available.
2550
2551 - new macros for database interaction: filldotrun.C, filldotrbk.C
2552
2553 - added new program which can convert colored output which was redirected
2554 into a file back into colored text (for example to display it with
2555 more): showlog
2556
2557 - added new program to display an MStatusArray of plots (stored with
2558 MStatusDisplay) from a file: showplot
2559
2560 - Added support for Sequences (MSequence). Sequences are blocks of run
2561 files containing the same calibration and belonging to the same
2562 source
2563
2564 - Added a new task (MTaskEnv) which can be used in setup files to switch
2565 between different tasks (for example to choose a signal extractor)
2566
2567 - Implemented automatic file splitting in MWriteRootFile
2568
2569 - After image cleaning an island index is assigned to all used pixels.
2570 The index corresponds to the order of the islands in size.
2571
2572 - added a cleaning which takes signal height _and_ arrival time into
2573 account: probability cleaning (for more details see MImgCleanStd)
2574
2575 - added a cleaning which takes takes the absolute number of photons
2576 times the area ratio as cleaning level
2577 (for more details see MImgCleanStd)
2578
2579 - Changed calculation of image parameters such, that it can be done
2580 for all used pixels or the pixels with a defined island index only
2581
2582 - implemented new image parameters displaying the number of islands,
2583 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2584
2585 - event display in executable changed to support also calibrated files
2586 (done with MJCalibrateSignal)
2587
2588 - added program doing the calibration and the signal extraction
2589 and signal calibration: callisto Most part of the setup is done
2590 by a resource file: callisto.rc
2591
2592 - implemented support for pixels with negative IDs (Raw file format
2593 version 4)
2594
2595 - implemented an new option in merpp (--auto-time) to get the time
2596 range for cc and/or caco data from the run header of the raw data
2597
2598 - New star-program (star and MJStar). Taking calibrated data from
2599 callisto/MJCalibrateSignal as input. The setup is done through
2600 a resource file: star.rc
2601
2602 - Added possibility to setup the eventloop in the mars-executable
2603 Camera Display by a resource file: mars.rc
2604
2605 - The the mars-executable Camera Display can now also read
2606 calibrated data files written by callisto/MJCalibrateSignal
2607
2608 - Added a new class which can calculate the source position in
2609 the camera from a pointing model known to be correct and
2610 the pointing model used for observations (MSrcPosFromModel)
2611
2612 - added a new version of the class calculating the effective on-time
2613 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2614 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2615 MHTimeDiffTheta.
2616
2617 - added the possibility to count how often a signal is above (or
2618 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2619 can replace MHTriggerLvl0)
2620
2621 - added ore convinient ways to set the axis-titles of your histograms
2622 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2623 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2624
2625
2626
2627 *** Version 0.8.5 (2004/08/06)
2628
2629 - new Signal Extractors: MExtractFixedWindowSpline
2630 and MExtractAmplitudeSpline
2631
2632 - implementes interleave in merpp to be able to merpp parts of a file
2633
2634 - implemented force-functionality to merpp
2635
2636 - star display to display star catalogs (MAstroCatalog)
2637
2638 - star display to 'mirror' stars to the camera (MAstroCamera)
2639
2640 - implemented a new cleaning option which allows cleaning scaled with
2641 the real ratio of the rms depending on the pixel size, not only the
2642 square root of the pixelsize (MImgCleanStd, MCameraData)
2643
2644 - removed obsolete MBlind* classes
2645
2646 - Signal extractor taking the AB flag into account implemented (this makes
2647 an odd number of slices for signal extraction possible
2648 (MExtractSignalABcorr)
2649
2650 - implemented a class extracting the pedestal from the raw-data (events)
2651 itself using empty lo-gain (MpedCalcFromLoGain)
2652
2653 - Added mean values to MPedPhotCam
2654
2655 - Added Makefile for Darwin (this OS is NOT officially supported!)
2656
2657
2658
2659 *** Version 0.8.4 (2004/04/19)
2660
2661 - new fast arrival time extractor using cubic splines:
2662 MExtractTimeFastSpline
2663
2664 - implementes multi-argument support in MDataChain
2665 ("pow(a, b)")
2666
2667 - implemented double reference support in MDataChain
2668 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2669
2670 - added support in MF for expressiond like
2671 "MHillas.fWidth<2*<MHillas.fLength"
2672
2673 - MDataChain is now able to support variables like [0], [1], ...
2674 which can be used in fit functions as parameters. The interface
2675 is implemented through the new virtual function
2676 MParContainer::SetVariables
2677
2678 - added new class MArrivalTimeCam/MArrivalTimePix:
2679 Storage containers to hold the ArrivalTime of the camera/pixel
2680
2681 - added new classes for the calibration of relative arrival times:
2682 MCalibrationRelTimePix and MCalibrationRelTimeCam
2683
2684 - added new classes to extract the signal of the blind pixel and the
2685 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2686
2687 - added new classes for the bad-pixels treatment (MBadPixels*)
2688 which are more powerfull than the old ones (MBlindPixel*)
2689 and will replace them.
2690
2691 - added filter against cosmics: MFCosmics
2692
2693 - added new class MArrivalTimeCalc2:
2694 Calculates the arrival time as the signal weighted mean of the time
2695 slices in the maximum window
2696
2697 - added a new macro call pointspreadfucntion.C that fits with a 2D
2698 gaussian the DC spot for an star. It gives you the RMS of
2699 the PSF and the center of the star, very useful for misspointing
2700 studies.
2701
2702 - added support for multi-telescope camera files. Added classes
2703 MStereoCalc and MStereoPar, classes to calculate and store shower
2704 parameters calculated from the data of two telescopes, for the MC
2705 studies regarding the MAGIC clone.
2706
2707 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2708 MC data calibrated in photons instead of ADC counts.
2709
2710 - added three macros to show the calibration and analysis chain of
2711 MC data. The macro starmc.C does both calibration and analysis, producing
2712 an output containing Hillas parameters for each event. The macro
2713 mccalibrate.C does just the calibration and writes out a file containing
2714 pixel information in photons instead of FADC data. The macro starmc2.C
2715 reads in such a file and produces an output with Hillas parameters.
2716
2717 - added MPedPhotCalc to compute pedestals in units of photons, see
2718 macro pedphotcalc.C
2719
2720 - added all class to perform the calibration, see macro calibration.C
2721
2722 - added class MFFT to perform Fast Fourier Transforms
2723
2724 - added class MSimulatedAnnealing to perform simulated annealing
2725 minimizations
2726
2727 - added new macro bootcampstandardanalysis.C which holds the skeleton
2728 of the analysis chain discussed in the december bootcamp.
2729
2730 - added support for DAQ raw data file format V2
2731
2732 - implemented an arbitrary time stamp for the events from raw-data
2733 files with file version<3. It is calculated from the run number,
2734 the date of start and the FADC clock tick from the first module
2735
2736 - implemented the correct decoding of the event time-stamp
2737 coming from the DAQ for raw-data files with file-version>2
2738
2739 - added a new classes storing the pedestals in units of photons:
2740 MPedPhotPix, MPedPhotCam
2741
2742 - added support for DC current files from the camera control
2743
2744 - added support for start- and stop-time when merpping report files
2745
2746 - added MReportCC storing the weather data from the CC-REPORT
2747
2748 - added class to fill trainings and test matrices (MTFillMatrix)
2749
2750 - added a filter performing a software trigger (MFSoftwareTrigger)
2751
2752 - Added classes to perform parts of the standard analysis (Jobs):
2753 + MJPedestals
2754 + MJCalibration
2755 + MJExtractSignal
2756 Note: All of them are preliminary!
2757
2758 - Added Iterator to iterate over files giving only the run-number
2759
2760 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2761 the evolution of a sector vs time
2762
2763
2764
2765 *** Version 0.8.3 (2003/12/05)
2766
2767 - adapted Random Forest classes to allow the use with MC
2768 multi-telescope files which can be produced with the coming
2769 camera version 0.7.
2770
2771 - added classes to read and interprete central control report files
2772 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2773
2774 - enhanced merpp (the executable) to support .raw and .rep files.
2775
2776 - added classes for light calibration (MCalibration* and
2777 MHCalibration*) by Markus Gaug. Further work has to be and will
2778 be done soon.
2779
2780 - Added a preliminary 'synchronizer' (MReadReports) which will
2781 replace MReadMarsFile as soon as it is finished.
2782
2783 - Added a tutorial macro demonstrating how report files are merpped
2784 and how they can be read from the root file in the correct order
2785 of time (readrep.C)
2786
2787 - Added a generalized histogram (similar to MH3) called MVsTime
2788 which allows to plot variables (or rules - MDataChain - of
2789 variables) vs time. For an example have a look at tempvstime.C.
2790
2791 - Changed the name of the event trees:
2792 + Events --> Events
2793 + PedEvents --> Pedestals
2794 + CalEvents --> Calibration
2795
2796 - changed name of MTime in the event trees from MRawEvtTime to MTime
2797
2798 - added displaying the sector indices to the mars event display
2799
2800 - Magic Online Analysis (MOnA) implemented in a first version
2801 (see mona.cc, MOnlineDump and MOnlineDisplay)
2802
2803 - added classes to calculate event rate
2804 (preliminary: MEventRateCalc, MEventRate)
2805
2806 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2807
2808 - added classes dealing with the telescope pointing position (MPointing*)
2809
2810 - implemented the 'final' Mars time stamp based on some experiences with
2811 the new 'Synchonizer'
2812
2813
2814
2815 *** Version 0.8.2 (2003/11/10)
2816
2817 - accelerated standard analysis by a factor of 6-8 ...
2818 + doing precalculations in MGeomCam for the pixel area ratio
2819 + creating a look up table for the single pixels in MCerPhotEvt
2820
2821 - added task to calculates weights in case you want to 'change'
2822 the energy spectrum of a monte carlo file
2823 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2824
2825 - added a new executable star which implements the
2826 star.C macro as precompiled executable. Currently a flexible
2827 setup is not possible, but a 'input card' setup will follow.
2828
2829 - Starting to implement Multi-Telescope-Support based on the
2830 upcomming camera version 0.7. The base for a general support
2831 is implemented and the star-functionality is proven to work.
2832
2833 - Replaced Event-Display in and Camera-Display in the Mars GUI
2834 executable by a more convinient display base on MStatusDisplay.
2835
2836 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2837
2838
2839
2840 *** Version 0.8.1 (2003/10/20)
2841
2842 - added signal subtraction for pure on data by means of fitting
2843 the background in the off region or by performing a combined
2844 signal/background fit. Provides necessary histograms for
2845 obtaining energy spectra and a light curve.
2846
2847 - added classes to perform and study the selection of the
2848 2nd Level Trigger on MC data (example in triglvl2.C macro)
2849
2850 - added pedestal calculation
2851
2852 - implemented "democratic cleaning" (tail cut value proportional
2853 to pixel area) according to Wolfgang's suggestion.
2854
2855 - added Sigmabar treatment (calculation and basic histogramming)
2856
2857 - added basic routines to apply padding
2858
2859 - added first implementation of MARS-based source visibility plotter
2860 (needs to be linked against slalib, preliminary version)
2861
2862 - enhanced functionality of data chains: random numbers, conversion
2863 functions and access to MHMatrix objects
2864
2865 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2866 numbers under certain circumstances (runs with 0 events included)
2867
2868 - fixed a bug in the general filter MF (didn't work on some systems
2869 at all)
2870
2871 - fixed a bug in chaining files, which caused the analysis to crash or
2872 ignore files
2873
2874 - implemented more geometry classes describing the parameters used
2875 to simulate the PMT camera
2876
2877 - added new Monte Carlo classes containing the setup of the different
2878 programs in the MC chain.
2879
2880 - added a (preliminary) general task to evaluate chi-square of a given
2881 parameter in an eventloop.
2882
2883 - first implementation of a container describing the observatory
2884 location (Long, Lat, etc)
2885
2886 - added Random Forest - method for g/h-separation
2887
2888 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2889 (this means, that it is compiling, but not yet fully tested)
2890
2891 - added a new status display which can show the present status
2892 of histograms while an eventloop is running (MStatusDisplay,
2893 an example can be found at status.C)
2894
2895 - reorganized directories:
2896 classes describing the image --> mimage
2897 classes containing Monte Carlo Histograms --> mhistmc
2898 classes for Random Forest method --> mranforest
2899
2900 - added (event-)weights to fill histograms
2901
2902 - colors in logging output to screen
2903
2904 - changes to the Image Parameter declaration:
2905 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2906 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2907 + MHillasExt now derives from MParContainer instead of MHillas
2908 --> Files written with the old definition are more or less unreadable
2909
2910 - reading of reflector files
2911
2912 - display data from reflector files in the camera
2913
2914 - implemented currents (and display them in the camera)
2915
2916 - logarithmic scale in camera
2917
2918 - added class to iterate through directory contents (MDirIter)
2919
2920
2921
2922 *** Version 0.8 (2002/11/18)
2923
2924 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2925
2926 - corrected 48(!) wrong entries in the Next Neighbor table of the
2927 Magic Camera (all in the inner part of the outer ring, mostly
2928 missing a single NN)
2929
2930 - Fixed a bug in the table describing the Next Neighbours of the
2931 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2932 have any neighbour)
2933
2934 - changed trigrate.C: now it calculates the pure NSB triggers from
2935 a camera file (generated with no showers), so there is no need
2936 to introduce them by hand in the BgR array (for more details
2937 please ask Abelardo)
2938
2939 - added MHHadronness (and MHadronness) as a general facility to evaluate
2940 the quality of a gamma-hadron seperation method
2941
2942 - changed MWriteAsciiFile to accept rules (MDataChain)
2943
2944 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2945 must be replaced by calles to MWriteAsciiFile::AddColumn and
2946 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2947 changed.
2948
2949 - Implemented generalized event-matrices (one row per event)
2950 (MHMatrix)
2951
2952 - implemented the one dimensional composite probabilities
2953 (MHCompProb, MCompProbCalc, comprob.C)
2954
2955 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2956 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2957
2958 - Added a camera display displaying the pixel numbers to the
2959 event display gui.
2960
2961 - Added Monte Carlo Informations to event display gui
2962
2963 - Changed the camera display to display the pixel numbering
2964
2965 - Added three buttons to the camera display to change the palette
2966
2967 - Added the number of used and core pixels after image cleaning
2968 to MHillas
2969
2970 - Changed the algorithm used in MHillas according to TDAS 02-03
2971
2972 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2973
2974 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2975
2976 - Added fCosDeltaAlpha to MHillasSrc
2977
2978 - The numbers of photons used to calculate fConc and fConc1 in
2979 MHillasExt are now scaled with the pixel size, so that one get
2980 a four times smaller value for the bigger pixels in the outer ring.
2981
2982 - added new task to smooth the camera contents (MCameraSmooth)
2983
2984 - added possibility to use interpolated pixel values for blind pixels
2985 instead of removing it completely from the analysis
2986
2987 - Implemented the possibility to save the whole eventloop with
2988 its setup to a file. This information can be read and from
2989 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2990 and MEvtLoop::MakeMacro. If you find something not working, please
2991 report - this stuff is still in a beta phase.
2992
2993 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2994 file having crab starfield, but also for all following files - fixed
2995
2996 - MTaskList::PrintStatistics can now be instructud to print also the
2997 title, too: use PrintStatistics(0, kTRUE)
2998
2999 - Changed the image cleaning so that pixels with to many 'used'
3000 neighbors are left used (to get rid of 'holes' in events)
3001
3002 - Introduced more output to the camera displays
3003
3004 - Added an array of histograms (eg one hist per run), MHArray
3005
3006 - Added a _preliminary_ version of the reader for CT1 PreProc files
3007 (MCT1ReadPreProc)
3008
3009 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3010 (thanks to Raquel)
3011
3012 - added the first energy estimator (MEnergyEstParam, estimate.C,
3013 estfit.C) using a parametrization
3014
3015 - Added some new Monte Carlo paremeter containers used to store
3016 setup information from the MC chain (MMcConfigRunHeader,
3017 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3018
3019
3020
3021 *** Version 0.7 (2002/04/30)
3022
3023 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3024 the pedestal mean value was saved incorrectly. For files from
3025 this versions we substract 0.5 from the pedestal mean.
3026 WARNING: This may effect your results, so don't wonder...
3027
3028 - First implementation of an algorithm using only triggered events
3029 for the collection area calculation
3030
3031 - Ascii Output can now also be used for parameter containers which
3032 doesn't overload MParCointainer::AsciiWrite
3033
3034 - The Ascii Output is now also capable of writing single data members
3035 of one container
3036
3037 - You are now able to change the order of the values written to the
3038 ascii file
3039
3040 - You can now specify a conversion factor for each data member written
3041 to an ascii file. This may be usefull to change the units of the
3042 data member (eg. degrees instead of millimeters in case of the
3043 hillas parameters)
3044
3045 - Replaced old MHillas by a new structure which allows you to extend
3046 the parameters stored in MHillas very easily:
3047 see MHillas and MHillasExt
3048
3049 - Added classes to handle source dependancy of image parameters:
3050 see MHillasSrc
3051
3052 - Added container (MBinning) to have a standard input for the binning
3053 in different histograms (eg. the Energy bins should be the same in
3054 all histograms)
3055
3056 - Changed Hillas histograms from mm to deg
3057
3058 - Added the flexible binning to the hillas histograms
3059
3060 - Added a filter for the alpha parameter (MFAlpha)
3061
3062 - It is now possible to write single data members of a class object to
3063 an output stream instead of the whole container only
3064
3065 - Added a generalized filter for a data member:
3066 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3067
3068 - Added a generalized Filter parser for more difficult filter rules
3069 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3070
3071 - Added new Monte Carlo histograms:
3072 MHMcEnergyImpact and MHMcEfficiency
3073
3074 - Added many new histograms needed for the flux calculation.
3075
3076 - Added a generalized histograms which can fill and show up to three
3077 data members in either a one-, two- or three-dimensional histogram, eg:
3078 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3079
3080 - Added:
3081 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3082 * calculation of <Theta> as a function of time (MHThetabarTime)
3083 they are needed in the flux calculation in
3084 order to select for a given bin in Theta (or time) the appropriate
3085 effective collection area, which is assumed to be given as a function
3086 of Theta and the true energy
3087
3088 - Added calculation of the migration matrix in the energy
3089 (MHMcEnergyMigration):
3090 the migration matrix describes the migration from the true (E_true)
3091 to the estimated energy (E_est); it is needed to determine the
3092 distribution of E_true from the measured distribution of E_est
3093 by unfolding
3094
3095 - changed the color palette in the camera display to DeapSea.
3096
3097
3098
3099 *** Version 0.6 (2002/01/15)
3100
3101 - Introduce the option of disable pixels (MBlindPixels and
3102 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3103 able to deal with Star Field NSB.
3104
3105 - Fixed a bug in the pedestals substraction
3106
3107 - Introduced verbosity levels
3108
3109 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3110
3111 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3112 work correctly (thanks to Abelardo)
3113
3114 - Introduced correct treatment of the diffuse Night Sky Background
3115 and NSB (MMcPedestalNSB)
3116
3117 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3118
3119 - Introduced MMcRunHeaders which contains monte carlo run informations
3120
3121 - Added a 'Print'-Task (MPrint) which calls the Print function
3122 of a parameter container for each event
3123
3124 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3125
3126 - changes to be more efficient with root 3.02/06
3127
3128 - root 3.02/06 fixes:
3129 + the memory leak when reading MRawEvtData
3130 + loosing more time than necessary to update the progress bar
3131
3132 - MWriteAsciiFile is now capable of writing more than one container
3133 in a line. For example: To be able to write Monte Carlo and
3134 Hillas values (energy and alpha) in one line.
3135
3136
3137
3138 *** Version 0.5 (2001/11/06)
3139
3140 - Added new GUI functionality (Analysis)
3141
3142 - Added a camera display to be able to display events in the camera
3143 together with the calculated hillas ellipse
3144
3145 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3146 object at any state of the analysis, so that the output are several
3147 states
3148
3149 - Fixed a bug in the collection area error calculation
3150 (Thanks to Ciro and Abelardo)
3151
3152 - Fixed a bug which causes merpp to crash in some environments
3153
3154 - Implemented auto enabling scheme for Branches to speed up reading
3155 a lot (see MReadTree and MTask)
3156
3157 - Fixed a bug in the Histogram classes which caused histograms to
3158 be written to a file by MWriteRootFile without request
3159
3160 - changed the object I/O from the old stylish root I/O to the new
3161 'auto evolution scheme' This was done only for classes which are not
3162 yet used in Monte Carlo files, so that these files are still readable.
3163
3164 - Added support for a progress bar in MEvtLoop and MReadTree
3165 (see the Analysis Window in Mars for an example)
3166
3167 - Fixed a bug in the package creation which disturbed the conversion
3168 between a mars version unpacked from a tar file and the repository.
3169
3170 - Changed the code to writer merpped (converted into root format)
3171 raw files, to get faster (around 10%)
3172
3173
3174
3175 *** Version 0.4 (2001/09/20)
3176
3177 - This release is made to compile on a root version >= 3.00
3178
3179 - Fixed a bug which causes MReadTree to read the first file only
3180
3181 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3182
3183 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3184
3185 - Added a task to write several container to a root file (MWriteRootFile)
3186
3187 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3188
3189 - Added calculation of the collection area (MMcCollectionAreaCalc)
3190
3191 - fixed some bugs in the Hillas calculation
3192
3193 - added filters to be able to control the task execution dependent on
3194 a parameter (for example: the number of level 1 triggers in a MC-file)
3195
3196
3197
3198 *** Version 0.3 (2001/04/23)
3199
3200 - Many demo macros added
3201
3202 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3203
3204 - Hillas Calculation added
3205
3206 - Standard image cleaning available
3207
3208 - MReadTree is now able to handle more than one file
3209 (Remark: of the same structure)
3210
3211 - Now we are able to display events in a first version of the
3212 Camera event display. To do this we must run the macro
3213 "macros/readCT1.C" to read data from CT1.
3214
3215
3216
3217 *** Version 0.2 (2001/01/24)
3218
3219 - First Implementation of a Gui to read the raw data. Start the
3220 gui with the command mars.
3221
3222
3223
3224 *** Version 0.1 (2000/12/20)
3225
3226 - First official release 0.1
3227
3228 - Changes:
3229
3230 + changed calling style of MRawPixelIterator from do...while to
3231 while-loop
Note: See TracBrowser for help on using the repository browser.