source: trunk/MagicSoft/Mars/NEWS@ 9401

Last change on this file since 9401 was 9394, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 131.9 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5
6
7== Version 2.3 (2009/03/07) ==
8
9 ;SUGGESTION
10
11 * There is no need to re-run any data because no change took place which
12 could have an effect on the output. However, if you want a
13 meaningful SrcPos plot for your MCs in sponde you must re-process
14 star for your MCs first.
15
16 ;REMARK
17
18 * File produced with this release containing a gamera geometry (which
19 are basically all files we produce per default) will not be readable
20 by older releases.
21
22 ;general
23
24 * fixed a few small bugs which could cause the display to crash in ganymed
25 and sponde
26
27 * in sequence file the date can now be omittet. In this case the
28 leading date with the underscore is missing in the expected filename
29
30 * the geometry class now also supports other geometries than just hexagons
31
32 ;automation
33
34 * added magnetic field Azimuth direction (ARRANG), currently
35 at ~ -7deg at La Palma
36
37 ;database
38
39 * plotdb.php: added default (sequences) for startup, added possibility
40 to set size of plot
41
42 * added a new table ''RunDataCheck'' which containes the rates after
43 image cleaning for every run which succeeded star. It can be
44 plotted using ''plotrundb.C''
45
46 ;merpp
47
48 * added support for Arehucas Version >= 200812140
49
50 * added support for Arehucas Version >= 200809030
51
52 ;mars
53
54 * The display now also displays the trigger pattern
55
56 * The display can now display ceres reflector (_R_) files
57
58 ;ceres
59
60 * added a uniformly distributed one-bin time jitter for the start of the
61 digitization. Otherwise the first photon would be digitized always with
62 the same alignment to the bins
63
64 * Added a plot showing the production height of the photons
65
66 * Moved the particle id from the event header to the run header
67
68 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
69
70 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
71
72 * Added many new options to control the tasks. For deatils see ''ceres.rc''
73
74 * Removed obsolete plots in pedestal and calibration mode
75
76 * Removed the non-NightSky photons from the plots where they are just
77 disturbing
78
79 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
80
81 * The daq event number now represents the readout number
82
83 * The camera ''electronics'' can now be ''switched off''
84
85 * A new tab ''Info'' now display basic things like the reflector
86 layout
87
88 * Improved reading speed for corsika files
89
90 * Improved memory handling (if a large ampount of memory was needed
91 for a single event all further events were stored in the same
92 memory and it was never freed, so the program took this memory
93 until the end)
94
95 * Converted the code from MMCS' reflector program to MSimAtmosphere
96 (instead of the tables build in for MAGIC Winter and Summer
97 atmosphere we use the values written by Corsika fitted to the
98 tabulated atmosphere given as input)
99
100 * For caluclating the displayed image parameters in ceres a basic
101 image cleaning removing isolated pixels is now done.
102
103 * The magnetic field direction (ARRANG) is now taken into account
104
105 * Added plot for the energy threshold after trigger ''Threshold''
106
107 * Added plot for the effective collection area after trigger ''TrigArea''
108
109 ;star
110
111 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
112
113 * The definition of fConcCore has slightly changed. The numbers
114 might decrease a little bit (the effect should be rather small)
115
116 ;ganymed
117
118 * added pointing model 328198
119
120 ;sponde
121
122 * The SrcPos plot for your MCs was so far meaningless because it just
123 displayes the MSrcPosCam data from the input star-files. Unfortunately,
124 this containes was never written to the star-files yet.
125
126 * A new Tab 'OnTime' is available which is an effective on-time
127 fit as in star but for all data. This is mainly for manual cross-check
128 of the effective on-time
129
130 * In some circumstances it might be necessary to re-calculate the
131 eff. on-time from the fit in the new tab, e.g. when a zenith distance
132 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
133
134 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
135 it to its own output file (for convinience)
136
137
138
139== Version 2.2 (2009/01/30) ==
140
141 ;SUGGESTION
142
143 * This release doesn't contain a major change which is expected to
144 change your results. Nevertheless there are small changes to
145 the calibration which can effect at least the first few hundred
146 events in any (mainly MUX and even more SUM) sequence a little bit.
147 So it is recommended although not necessary to reset your sequences
148 in the database before further processing.
149
150 ;NEW
151
152 * A first implementation of a Monte Carlo simulation program
153 (ceres - Camera Electronics and REflector Simulation) has been
154 implemented. It can simulate a full telescope already including
155 a complete reflector simulation and a flexible trigger and readout
156 simulation. Currently, no perfect setup is implemented and
157 especially the output of the program (data structure) should
158 be considered alpha state. Also the user interface is not yet
159 ready.
160
161 ;general
162
163 * All command line options after -- are now interpreted as
164 arguments (usually everything which doesn't start with a minus)
165 rather than options (usually everything which starts with a
166 minus). This allows to use file names starting with a -
167
168 * In all resource files you can now initialize the random number
169 generator. For details see: MJob::InitRandomNumberGenerator
170
171 * added a new program called ''readcorsika''. It's purpose is (in analogy
172 to readraw and readdaq) to read a Corsika output file (for now
173 only cherenkov output is supported) and print its contents in a
174 human readable form. It can also write the contents of this file
175 into a root-file.
176
177 * The calculation of the maximum distance to the origin in a MGeomCam
178 has been improved (edges might be further away than the sides).
179 This is just a tiny change but it might change the appearance of
180 the radial profiles a little bit.
181
182 * The default binning of the center-of-gravity plot has slightly been
183 increased
184
185 ;Database
186
187 * Added informations about the DC currents (fMinCurrents, fMedCurrents
188 and fMaxCurrents). The values are retrieved from the plots showing
189 the average DC currents of all pixels versus time.
190
191 * Websites with tables have now the opportunity to remove lines
192 ('-' button at beginning of each line) and get all lines back
193 ('+' at top of the column)
194
195 * Websites: added option to query only sequences containing sumtrigger
196 events
197
198 * Websites: added option to group by date (year, month, night) for runs
199 and sequences and enabled that combining of different group-bys,
200 e.g. status, date and source is possible
201
202 ;automatic analyis
203
204 * Rewritten producing plots in the web.
205 New plots, namely the output of plotoptical.C (extinction curve from
206 KVA), plotstat.C (status of the automatic analysis (percentage of
207 processed, analysed data etc.)) and plotusage.C (statistics of the
208 condor usage in the data center) has been are available now next to the
209 plots of plotdb.C
210 Mean values from the plots (output of the macro) are provided in a
211 txt file now.
212 The creation of the plots for callisto, star and ganymed in the web is
213 now steered via database. Consequently the plots are faster and
214 reliable up-to-date.
215 For all plots, a new layout is available facilitating the browsing
216 through the plots and providing additional information on the
217 displayed values. (tabs.php) These plots are linked from the DB
218 websites and the wiki.
219
220 ;statusdisplay
221
222 * The ''Loop'' entry in the menu bar now contains an option to pause
223 the loop and to process single events.
224
225 ;merpp
226
227 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
228 instead of RunHeaders)
229
230 * Now allows to merpp files newer than 2008/09/03.
231
232 * Added fixes for wrong (wrong or double) run- and file-numbers
233 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
234
235 ;callisto
236
237 * Extracting the pulse position for the pulse position check events
238 with sum trigger were denied. This decreased the statistics
239 extremely and therefor the resulting puse position was calculated
240 quite weak. Now sum events pass the calculation if and only if they
241 have also a level 1 trigger.
242
243 * the extraction of pedestal events and pulse position from the
244 first data events is now more automatic and makes sure that
245 a more precise number of events is extracted independent of
246 the ratio with which pedestal events or events with signals
247 are contained in the data.
248
249 * Updated Muon calibration constants for all MUX data (teh changes were
250 all smaller than 5%)
251
252 ;star
253
254 * For the calculation of the effective on time all sum-triggered events
255 were skipped. Now all Level1-triggeres events will pass. This might
256 result in a slight inaccuracy of the effective on time.
257
258 ;ganymed
259
260 * If the source position is more than 1deg away from the camera
261 center an error is raised now.
262
263 * Hopefully fixed the bug ''ganymed crashes when resized''
264
265 ;sponde
266
267 * Fixed a problem which causes the fitted spectral slope to be displayed
268 incorrectly. If you use MJSpectrum::FormFlux in your macros make
269 sure that the parameter 0 of your fit is negative.
270
271 * Added a histogram showing the read source position of your MCs
272
273
274
275== Version 2.1.1 (2008/08/04) ==
276
277 ;Database
278
279 * Added the median number of photo electrons from the calibration
280 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
281 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
282
283 * Added fTotOnTime, which is the on-time as given by the run-headers
284 (in contradiction to fAbsOnTime which comes from CC)
285
286 * Added new primaries for the new data structure (Magic II): for the
287 tables dealing with sequences (SequenceBuild Status, Sequences,
288 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
289 this is the telescope number (fTelescopeNumber) for the tables dealing
290 with runs (RunData and RunProcessStatus) this is in addition the file
291 number (fFileNumber)
292
293 * Added column fPriority to the status tables to be able to steer the order
294 in which the data is processed. As default the run, sequence and dataset
295 number are used.
296
297 ;automatic analyis
298
299 * Adapted scripts to the new data structure: They can handle now different
300 telescopes (getting the information as usual from the database).
301 The paths for Magic 2 are not yet implemented.
302
303 ;general
304
305 * should work now with root 5.20/00 (please note that root 5.20/00
306 we encounter crahses in the status display which are ot yet
307 understood)
308
309 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
310 instead of the base name of the file. This makes them easier to
311 access from the code
312
313 * Default Monte Carlo names in MSequence do not require the _E at
314 the end anymore
315
316 * where abrrevating a sequence file with a sequence number is possible
317 also "telescope:sequence" is now accepted, e.g.:
318 star 2:2000123 --out=output
319 see the programs' help for more details.
320
321 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
322 from the database. See the constructors for more details.
323
324 * MReadTree now supports friends
325
326 * MReadTree can now read also files not written by MARS and store
327 the data encapsulated in emulated MParContainers
328
329 * added a new starguider calibration valid since 15.1.08
330
331 ;showplot
332
333 * showplot can now read more than one file at once. This is especially
334 inetersting if reading files containing pure canvases
335
336 ;merpp
337
338 * we merpp the dc currents now also from the camera reports (they have
339 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
340
341 * In the automatic analysis we omit merpping of the currents from the
342 caco files and use the lower rate camera reports from the cc files
343 instead
344
345 * merpp has been redisigned to allow merpping of the cc-reports
346 of a whole sequence. This allows to design a very simple analysis:
347 mkdir output
348 ./callisto 100776 --out=output
349 ./merpp 100776 output
350 ./star 100776 --ind=output --out=output
351 Instead of the sequence number also sequence files are accepted.
352
353 * Implemented a fix for run-numbers between 1001348 and 1001396
354 which were incorrectly assigned by the cc.
355
356
357 ;callisto
358
359 * added a filter again which was was removed in the last release.
360 it removed the most brightest events. This should not change
361 any analysis result because these events are so bright that
362 they cannot be analysed anyway, but the bad-pixel plots doesn't
363 show outliers.
364
365 * updated muon calibration constants for the periods 51-57,
366 58-63 and 67-
367
368 ;star
369
370 * The camera currents are now displayed with the rate of the camera
371 reports instead of the caco reports
372
373 ;ganymed
374
375 * if mc camera files are new enough (>=8) the source position in the
376 camera is now calculated from the stored telscope and shower
377 orientation (Note, that this might not be suitable in all cases
378 depending on the aim of the study. These case still needs
379 implementation)
380
381
382
383== Version 2.1 (2008/06/18) ==
384
385 ;Database
386
387 * introduced average temperature and wind speed from star-files
388
389 * introduced average values from Pyrometer (mainly Cloudiness)
390
391 * introduced the ratio of accepted calibration events in the
392 calibration run
393
394 * introduced the average rates of the different trigger pattern,
395 e.g. the rate of pedestal and calibration events, from the signal-file
396
397 ;general
398
399 * fixed GroupBy options in plot*.C macros
400
401 * only display KVA points (not the Tuorla points) in plotoptical.C
402
403 * all programs now allow to add resources to the ones from the resource
404 file or overwrite them from the command line. This can be done like this
405 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
406 if something seems to be wrong you can debug what the program is doing
407 using the option --debug-env=3
408
409 * increased the diversity of debug levels. That also means that with -v3
410 you get now less output, i.e. only the output which is important for
411 an analysis. To get more output which helps for debugging try 4, 5 and 6.
412
413 * fixed a problem in the task synchronizing the reading of the reports
414 and the data stream. The effect was that in some circumstances the last
415 events of some trees could have been skipped. Since this is only a
416 very tiny part of the data no severe effect to your analysis results
417 is expected (an exception might be very short, i.e. singel runs,
418 datasets).
419
420 * Dataset file now allow to include the sequence file directly within
421 the dataset file and also allow to exclude single runs from the dataset.
422 (for more details see Class reference of MDataSet)
423
424 * Sequence files now allow for excluding runs from the analysis
425 (for more details see Class reference of MSequence)
426
427 * added code to process the sum-trigger flag
428
429 * the histogram classes MH3 and MHn now support profile histograms
430
431 * the histogram classes MH3 and MHn now support labels at the axis
432
433 * the Random Forest Train-classes (MJTRain*) now store the used datasets
434 in the output file
435
436 * the MFMagicCuts have a new option to allow a linear area cut (for
437 special studies)
438
439 * The liniking of the shared object is now done into a file defined
440 by 'mktemp'. This should be a local file system which accelerates
441 liniking a lot.
442
443 * The code has been prepared for compilation with root 5.18/00d
444
445 * The MHEnergyEst histogram now shows the distribution of
446 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
447 and (Eest-Emc)/Emc vs Emc.
448
449 * fixed mars (event display) for merpped raw-data and MC data
450
451 * adapted the synatx of sequence files to allow for the new run/file
452 scheme. For more details see class description of MSequence
453
454 ;showplot
455
456 * Added support for tiff files
457
458 * Added support for csv files (tables containing tab number,
459 name and title)
460
461 * Tabs now can have a title which is displayed in the postscript file
462
463 * When multiple file are written at once (e.g. pngs from a display)
464 it is now possible to use the tab name and or tab number in the
465 file name. For details see showplos's help.
466
467 ;merpp
468
469 * Implemented cc file version 2008-02-20/0
470
471 * Implemented cc file version 2008-05-19/0
472
473 * With new options merpping can be restricted (in addition to the
474 run-number) also by telescope and file number.
475 For details see "merpp --help"
476
477 * Implemented raw data format 11 (the most important change, except
478 from plenty of changes in the format definition, is the addition
479 of the file-number in the header) If nobody makes a mistake this
480 format should have the advantage that it is by definition forward
481 compatible, so old programs will be able to read newer formats.
482
483 * Added Pyrometer information to default output (stored in a new Tree
484 Pyrometer, needs a complete new merpp, i.e. new calibration)
485
486 * Merpping (also update) can now be restricted to one single report.
487 For example:
488 If you want to update an old file with Pyrometer information call
489 merpp --only=Pyrometer --update
490
491 ;callisto
492
493 * in the pedestal processing now at least 50 processed events are
494 required for succeeding.
495
496 * the signal and calib files now contain also the sequence information
497
498 * the two MPedestalCam in the calib file now have proper names
499 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
500
501 * Both pedestal cams now contain the number of events processed
502
503 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
504 i.e. for the extraction of the calibration pulses basically the average
505 over all events of the first slice instead of all slices was used.
506 Since pedestal and calibration constants are continously recalculated
507 this only effected the very first events of every sequence.
508
509 * For the extraction of the position of the maximum sample now the
510 extraction range is set automatically to the extraction window,
511 before the whole accessible range was used.
512
513 * If the number of samples in the events and the number of samples
514 in the run-header disagrees now an error is raised (this can
515 happen in not well simulated Monte Carlo files)
516
517 * In the case of MUX-data pedestal events with the lvl1 trigger flag
518 could survive into the pedestal calculation -- fixed.
519
520 * Tab "TrigPat" added showing the distribution of the trigger pattern
521 as found in the run-files (normalized with the run length)
522
523 * The selection of events from the trigger pattern has been improved.
524 If the trigger pattern is corrupted events won't pass anymore.
525
526 * Added a new command line option --dev-null to suppress output of
527 Y-files (this is useful for test cases)
528
529 * added a new tab "CalPos" showing the arrival time of extracted
530 interleaved calibration events
531
532 ;star
533
534 * the star file now contains also the sequence information
535
536 * Added a new command line option --dev-null to suppress output of
537 I-files (this is useful for test cases)
538
539 * Tab "Rate" added showing the distribution of the trigger pattern
540 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
541 the Y-files (normalized with the run length)
542
543 * The effective on-time calculation doesn't use events with only
544 sum-trigger anymore
545
546 * The data in the MHWeather tab has been reorganized. The never
547 working solar radiation has been removed and the data from
548 the pyrometer (cloudiness, air and sky temperature) is
549 displayed in addition.
550
551 ;ganymed/sponde
552
553 * Now data points are even shown correctly if they have error bars larger
554 than one sigma. Points with null or negative significances are omitted.
555
556 * DrawNicePlot now allows to set a projection range
557
558 * Updates pointing models. One is applied after the implementation
559 of the new LUTS in August, the other one is applied after the
560 next major change of the pointing model in October. Note that
561 these models are preliminary and give wrong results below Zd=65deg
562
563 ;sponde
564
565 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
566
567 * a new option "--force-runtime" is available. In case of very short
568 datasets (for light-curves) which are in the order of a few
569 minutes the calculated effective on-time is not very acurate because
570 it is quantizised in the order of a minute. Therefore you can switch
571 to using the real run-time instead (remakrt: this ignores any
572 dead-time!)
573
574 * a more analytical way is used to "fill" Monte Carlos into regions
575 of impact parameters which have not been simulated because the
576 trigger efficiency is assumed to be 0.
577
578 * estimated sensitivity curves for hi and lo zenith angles are shown
579 scaled to the correct observation time and collection area
580
581 * the Monte Carlo events after cuts are now written to the output file
582 if an output file given
583
584
585
586 *** Version 2.0 (2007/09/03)
587
588 - database: the position used for the pulse pos check was missing
589 in the callisto output and could thus not be filled into the DB.
590 Also the old values seemed not exactly the PulsePos used for
591 teh check.
592
593 - general: Resource file now allow an Include-Resource, i.e. you can
594 read a resource file with default settings, include it in your
595 resource file and overwrite the settings in your file. More than
596 one include file is allowed. Inclusions can be iterative.
597 Include: mydefaults.rc yourdefaults.rc
598 The resources in the first file have higher priority than the
599 second file.
600
601 - general: Now the output files (calib*.root, etc) also contain the
602 resource file (to check it open it in the TBrowser and choose Print()
603 from the context menu)
604
605 - general: Dataset files now allow to overwrite the default path
606 to search for sequence and data files. Note, that the program
607 option and individual resources will overwrite it. For example:
608 SequencePath: /magic/montecarlo/sequences
609 DataPath: /magic/montecarlo/star
610
611 - general: Fixed a problem with variables in MDataPhrase. It seems
612 that only optimdisp (didn't work) was effected.
613
614 - general: Some improvements to the optim and train processing. For
615 example the ststud window now got a proper title.
616
617 - general: The "Status Display: " was removed from the window title
618 within an Eventloop.
619
620 - general: added a new flexible histogram-class (MHn) which can be used
621 for example in testing after optimizations or training to produce
622 user defined histograms.
623
624 - general: The Random Forest now allows attaching an evaluation
625 function which is applied to its output. This allows to train
626 on whatever you like (eg. train on log10(energy), but return
627 energy)
628
629 - general: The Random Forest training of energy (trainenergy.c) and
630 disp (traindisp.C) has been improved by more graphical output to
631 judge the result.
632
633 - general: The training of energy (trainenergy.C) has been improved
634 a lot by training on a different quantity than energy. It gives
635 a result which is highly independant of the source spectrum
636 and shows lower bias than all other options.
637
638 - general: Dataset files are allowed to contain collections of
639 datasets. For more details see the class reference of MDataSet.
640
641 - general: The default WobbleMode in a datset file now (if not
642 overwritten) is "auto", i.e. wobble mode is set if the dataset
643 doesn't contain off-sequences.
644
645 - merpp: Merpp can read file format version 9 now. Please realize
646 that for file format version 9 the extraction range is different
647 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
648 the first and last 15 slices have been removed from all MUX data.
649
650 - mars: Similar to writing movies you can now select events which
651 should be displayed in your display. Therefore add the following
652 lines to your mars.rc:
653 MFEvtNumber.FileName: ganymed00223552.root
654 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
655 The input file can be a ganymed-file after (ganymed*.root) or
656 before (ganymed*-summary.root) file. For example to select all events
657 from your on sample after cuts (excluding the ThetaSq cut) use
658 MFEvtNumber.Selector: DataType.fVal>0.5
659 To show all events from your on-sample after quality cuts
660 use the summary file instead.
661
662 - mars: new ways to call mars are implemented. Instead
663 of calling
664 mars filename.root
665 you can now also use
666 mars sequence.txt
667 or
668 mars sequence.txt inputpath
669 or replace sequence.txt by the sequence number if the default
670 sequence file should be used.
671
672 - mars: The default size has been increased
673
674 - mars: There are two new heckboxes which allow to switch off
675 the calculated image parameters
676
677 - callisto: was broken for MCs... fixed.
678
679 - callisto: improved calculation of spline coefficients a lot. This
680 leads to a further improvement of the event rate calibrating MUX
681 data of about 15% (175evt/s instead of 150evt/s)
682
683 - callisto: finally the raw data we read is now real 16bit (with
684 10bit precision) for MUX data and not a stripped 8bit number
685 anymore. Due to scaling of the numbers (without precision loss
686 into an [0-256[ range, the final numbers for pedestal, pedestalrms
687 and extacted signal don't change. However, at all places where
688 raw data is directly accessed (eg. saturation and variation
689 limits in the signal- and pedestal-extraction) the numbers
690 refer still to the data's 16bit range.
691
692 - callisto: The maximum arrival time difference used in the bad
693 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
694 for both, old FADC and MUX-FADC, data.
695
696 - callisto: Be aware that callisto is now calibrating the arrival time
697 in nanoseconds rather than time slices. Also all following tasks
698 have been changed to assume ns units now. If you star data
699 calibrated with an older version it might be necessary to adapt
700 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
701 to obtain optimal results. The plot in the PulsePos tab
702 will now be in ns, too. This might also mean that the Muon
703 analysis in star might not work as perfect as expected as long
704 as old files read in.
705
706 - callisto: The calibration constants of earlier updates got lost
707 somehow. All constants have been updated.
708
709 - star: The PSF is now determined from the profile of the ArcWidth
710 instead of arcwidth/radius. The old way gave to much weight
711 to the bins with low statistics. The reference lines have been
712 updated.
713
714 - star: For speed reasons events suitable for the muon analysis
715 are now also preselected by fConcCOG<0.1 which seems to be a very
716 good preselector for muons.
717
718 - star: is now calculating a new timing parameter the Slope along
719 the major and minor axis of the shower. Therefore a numerical
720 solution of a line-fit is used. To use MHillasExt.fSlopeLong
721 and MHillasExt.fSlopeTrans don't forget to multiply it with
722 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
723
724 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
725 have been removed from MNewImagePar. They have never been good for
726 anything.
727
728 - star: Implemented a new recursive algorithm which is supposed to be
729 faster. Also implemented new cleaning oiptions, which are:
730 + CleanLevel0:
731 The cleaning level above single core pixels can be kept
732 + KeepIsolatedPixels:
733 Define whether single core pixels should be kept
734 + TimeLevel1:
735 The coincidence window in nanoseconds to single used neighbors
736 + TimeLevel2:
737 The coincidence window in nanoseconds to two used neighbors
738 + PostCleanType:
739 MOde in which a time dependent post cleaning should be applied
740 0: No post cleaning
741 1: Require for each used pixels at least one used neighbor
742 within a time-window of CleanLevel1
743 2: Require for each used pixels at least two used neighbor
744 within a time-window of CleanLevel2
745 3: Require first two and second one used neighbor
746 within a time-window of CleanLevel1 and fCleanLevel2
747 respectively
748 + RecoverIsolatedPixels:
749 - recoveres isolated core pixels if they have a used neighbor
750
751 - mars/star: The new default cleaning is:
752 + CleanLevel1: 6.0
753 + CleanLevel2: 3.0
754 + CleanTime1: 1.75
755 + CleanTime2: 1.75
756 + PostCleanType: 3
757
758 - star/ganymed: The old spark-cuts have been replaced by new ones.
759 These new spark cuts have been cross checked with the sequences
760 84720 (before splitter), 101041 (after splitter) and 223539 (new
761 FADCs). In all cases they seperate pretty well, but of course not
762 perfect. Monte Carlos have suggested to tighten the cuts a little
763 bit further at low sizes. This has been done.
764
765 - ganymed: IMPORTANT - The spark cuts have been changed to match
766 all available data more or less well. This might mean that for
767 YOUR data there are still sparks visible.
768 Whenever you do an analysis you have to make sure that NO sparks
769 survive your cuts!
770
771 - ganymed: The old hadronness and size cuts have gotten new indices
772 (10, 11). The old indices 8 and 9 now mean an additional condition
773 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
774 If you want to switch off this cut just move the line far away enough,
775 e.g. by setting c[9] to -500. Please update your ganymed.rc files
776 accordingly!
777 The unit of c[9] is deg. It is the dist at which your cut will
778 cross the slope==0. The unit of the slope is ns/deg. So if
779 you readin files calibrated with an older Mars-version you
780 have to adapt the default value for c[9] to the FADCs:
781 - Multiply by two for the MUX FADCs (run number > 200.000)
782 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
783 - Multiply by 42 for the meaning of life (run number = 200.000)
784
785 - ganymed: The old Cut0 is now called CutQ and is calculated before
786 the source position is caluclated. If you need a quality cut
787 including source dependant data (be very carefull with this!)
788 you have to use Cut0 instead.
789
790 - ganymed: now properly supports three off regions in wobble mode.
791 It will be the default from now on in ganymed_wobble.rc. To change
792 the number of off-regions use
793 NumOffSourcePositions: 1
794 in your ganymed.rc. Also by default no off-theta cut will be done
795 anymore so that you will get a background level higher than the
796 signal level in your ThetaSq plot for ThetaSq>0.2.
797 Due to this be carefull changing the scaling mode away from
798 "None". You will underestimate your signal if your scale interval
799 is not properly set.
800 (Rem: ThetaSqN is no longer needed)
801
802 - ganymed: is now storing the events of all (on- and off-)
803 source positions even in the case of more than one off-source
804 position. This should allow sponde to work properly and the
805 energy estimation is done correctly in all cases (without any
806 "nearest position" trick)
807
808 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
809 with a real pointing model for the starguider is done, calibrated
810 with more than thousand tpoints taken from this date on.
811
812 - ganymed: was broken for Wobble-MCs... fixed.
813
814 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
815 has changed. Note that your old ganymed.rc will be incompatible
816 with the new algorithms! Please check the ganymed.rc files and
817 the class description of MFMagicCuts for more information.
818 It is recommended at the moment to use identical Disp-Parametrizations
819 for on/off- and wobble-mode. If cuts are optimized only
820 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
821 should be optimized. All other values should be kept as they are.
822 If you want to do an anylsis without timing a parameters, you can
823 switch off the timing cuts by seeting parameter 7 to a very small
824 value (eg. -99). To remove the slope parameter from the disp
825 paremtrization set parameter 8 to 0.
826
827 - ganymed: The distribution of observation time versus zenith
828 angle is now shown for off- AND on-data.
829
830 - ganymed: The contents of the source position plot are no longer
831 averaged, thus a lot of (fake) events between the two wobble
832 positions have disappeared.
833
834 - ganymed: There is a new tab "CutT" it contains the VsSize plots
835 with the CutT, whihc is defined in ganymed.rc, applied. It
836 is resonable to use your theta-cut for it, to see if there is
837 something strange (sparks!) in your signal-region.
838
839 - ganymed: To choose a dataset from a collection in a dataset file
840 use the new command line option "--dataset=12345"
841
842 - optim, sponde: should now properly support three off-regions.
843 Just produce your ganymed summary files with three off-regions.
844 optim and sponde will automatically get all off events from
845 all off-regions from this file. Please do not forget to
846 set the scaling in optimwobble.C properly:
847 fit.SetScaleUser(1./3);
848 it is not yet read in automatically (will follow soon).
849 In the case of fixed Scale you can also use
850 cuts.SetThetaCut(MFMagicCuts::kOn);
851 no off-cut needed.
852 Be carefull in case of three off-regions when switching on
853 scale mode. Make sure that the scale interval is set correctly.
854
855 - sponde: sponde.rc and sponde_onoff.rc are now idetical
856
857 - sponde: the resouce files have been rewritten with a lot of
858 comments and a well working parametrization for an energy estimator
859
860 - sponde: In the estimated energy versus monte carlo energy plot the
861 contents where exchanged.... fixed.
862
863 - sponde: the so called "accurate"-mode has been removed. It didn't
864 give any improvement in accuracy, only decreased execution speed.
865
866 - sponde: the so called "simple"-mode has been removed. It didn't
867 give any improvement in simple.
868
869 - sponde: the so called "refill"-mode has been removed. It was anyhow
870 not implemented.
871
872 - sponde: now checks whether the theta distribution of your on-data
873 and the theta-distribution of your Monte Carlo sample (after
874 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
875 sample is incomplete) execution is stopped. Execution can be forced
876 using the new option --force-theta. Use this option with care!
877
878 - sponde: Proper collection areas can now be constructed also from
879 Monte Carlo samples generated with different maximum impact
880 parameters. Note that in previous version you neither got
881 a warning or failure, nor was there any obvious sign that the
882 collection area was overestimated due to usage of files with
883 different maximum impact parameters.
884
885 - sponde: If MC files with different lower energy limits are used
886 the primary MC spectrum is artificially completed down to the
887 lowest energy used at all. WARNING: that this gives correct
888 collection areas ONLY if none of the events in this region would
889 survive your cuts at all.
890
891 - sponde: the output file now contains more information about
892 the spectrum (eg. the full 2D collection area histogram).
893 Note, that this information can only be written to the file
894 if it is stored automatically via command line argument.
895 If you only store the status display from within the display
896 the information is lost.
897
898 - sponde: added a new tab "Disp". It shows the residual of the disp
899 (Disp-Dist) versus several parameters and it is meant to judge the
900 quality of the disp estimator. In the ideal case the residual is zero
901 and doesn't depend on any variable. The tab is displayed after
902 CutQ and Cut0.
903
904 - sponde: added a new tab "Energy". It shows the residual of the
905 energy (lg(estimated energy)-lg(monte carlo energy)) versus
906 several parameters and it is meant to judge the quality of the
907 energy estimator. In the ideal case the residual is zero
908 and doesn't depend on any variable. In reality even a good estimator
909 can show residuals versus Monte Carlo energy. The tab is displayed
910 after all cuts.
911
912 - sponde: added a new tab "EventDist" showing the unweighted real
913 absolute number of events of your sample after cuts. This tells
914 you how many events with this energy you had in your MC files.
915 The same information you get from the error bars of the weighted
916 histograms, but this is less intuitive.
917
918 - sponde: The spectrum plots now show the crab- and 1553-spectrum
919 for comparison. It is not meant to show these curves in
920 publications, they are only for production.
921
922 - sponde: The OriginalMC tree with the events produced by corsika
923 is now processed only once
924
925 - sponde: Finally fixed most annoying bug, which has effected the
926 last bin of the collection area. It was the problem that binnings
927 of root histograms are from 1 to n (included) but there was a C-like
928 loop in sponde from 0 to n (excluded). Now the loop also includes
929 correctly under- and overflow-bins. The worse thing with this is,
930 that for the events in the highest bin not only the bin-content
931 was wrong, but also the weights applied to these events, which could
932 in pricipal effect also other parts of the distribution (eg. due
933 to energy estimation). Fortunately it effected only a few events
934 in most cases.
935
936
937
938 *** Version 1.2 (2007/05/14)
939
940 - database: The database now has two new values Unsuitable50 and
941 Unsuitable01. They express the number of pixels which are
942 unsuitable for more than 50%, respectively more than 1%, of
943 all calibrated event. It is a more accurate number than the
944 previously used numbers, because they only take the first
945 calibration (ignoring the interleaved calibrations) into account.
946
947 - database: The database now has two other new values UnsuitableMax and
948 DeadMax. They express the maximum number of pixels which were
949 unsuitable, respectively dead, during the sequence. Because
950 of high pedestal rms (cars passing) a few events with very high
951 numbers of unsuitable pixels can happen. Not to suffer from this
952 effect we don't take the highest 0.1% of the numbers into account.
953
954 - general: fixed a bug which caused callisto and star to stop working
955 properly because the callisto output was currupted
956
957 - general: a script called scripts/makemovie has been added which
958 simplified the process of producing several movies from a single
959 sequence with different setup.
960
961 - callisto: Some more code cleanup. Started to remove old obsolete
962 code from cvs.
963
964 - callisto: The extraction of the pedestal with the extractor was
965 not random. It seems that extracting at one position is still biased
966 (for example in the first or last slices we could still suffer from
967 switching noise) Now it is completely random.
968
969 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
970 pedestal files) individual pixels could be skipped due to high
971 variations. This was already the case for the pedestal extraction
972 from the lo-gains since the beginning and properly handled
973 there, but was introduced in the extraction from the pedestal files
974 a while ago. To calculate the average value it was still divided
975 by the number of events procesed not by the number of summands
976 really summed. This let to a pedestal which was a tiny amount too
977 small (for a few piels in the order of 0.1%). This led to an slightly
978 positive offset of the randomly extracted pedestal for a few pixels.
979 I doubt that this has a big effect on the result, because the effect
980 on the individual numbers is quite small. Due to this it is suggested
981 that you rerun your calibration to make sure you are without any
982 avoidable bias.
983
984 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
985 the median rms of the absolute arrival time and expressed in significance
986 levels. This replaces the old meaning of an abolute upper limit. An
987 absolute upper limit doesn't make much sense, because in our data
988 all arrival times are shifted at the same time (in fact it might be
989 a shift of the artificial trigger w.r.t. to the light flash).
990
991 - callisto: Added a new tab "BadPixTm" which shows the time evolution
992 of the number of unsuitable pixels over the whole sequence. This
993 is usefull mainly to judge if an intermediate calibration had
994 problems.
995
996 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
997 of the number of dead pixels over the whole sequence. Dead pixels
998 in this context are unmapped pixels, i.e. pixels which could not
999 be interpolated, and thus are ignored in the further analysis.
1000
1001 - callisto: It is now possible to use the position of the maximum
1002 of the spline as arrival time instead of the leading edge even
1003 when using the integral for the signal. Therefor set the extraction
1004 type to kIntegralRel ("IntegralRelative") and the relative height
1005 ("HeightTm") to -1:
1006 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1007 MJPedestalC1.ExtractSignal.HeightTm: -1
1008
1009
1010
1011
1012 *** Version 1.1 (2007/04/27)
1013
1014 - general: The new class MGeomCamDwarf contains the camera geometry
1015 for our prefered Dwarf camera and can be used to create general
1016 geometries of roundish or hexagonal cameras.
1017
1018 - mars: The default cleaning is now abolute 8.5/4.0.
1019
1020 - mars: The resource file mars.rc now contains examples for MUX data
1021
1022 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1023 data containing only 10-bit information is still cooked down to
1024 8-bit, by cutting away the lowest 8-bit.
1025
1026 - merpp: When reading raw data the data is now stored in a single
1027 array. The lo-gain array is obsolete. The interface stays the same.
1028
1029 - callisto: To process the new MUX data use the resource file
1030 callisto_mux.rc
1031
1032 - callisto: The -root and -raw options to read merpped raw data have
1033 been removed
1034
1035 - callisto: If the -mc option is given the sequence-name can now be
1036 replaced by the MC sequence number
1037
1038 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1039 -mc option can now be omitted
1040
1041 - callisto: Started further simplification by removing obsolete
1042 dependancies on MCalibIntensity*Cams.
1043
1044 - callisto: removed unsused intensity calibration from MJCalibration
1045 for further simplification
1046
1047 - callisto: for simplification removed references to
1048 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1049 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1050 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1051 (this should at minimum change nothing at all, and at maximum
1052 improve thing if these containers where somewhere not handled
1053 properly)
1054
1055 - callisto: Added the option to write an event movie. Please use
1056 this option with care (huge files) but exessively to understand
1057 our events. For further documentation please refer to the
1058 IACT wiki
1059 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1060
1061 - callisto: Improved binning for the pulse position check histogram
1062
1063 - callisto: The code calculating the pulse position checknow takes
1064 the pedestal into account
1065
1066 - callisto: The arrival time is now stored with full precision this
1067 helps to get rid of artefacts in histograms. For the signal this
1068 is not necessray because it is displayed in log-scale anyhow
1069
1070 - callisto: Fixed a problem with internal exclusions. Pixels which
1071 have once been marked as unsuitable didn't get the necessary
1072 histograms filled anymore to be rechecked with each interleaved
1073 calibration.
1074
1075 - callisto: The relative arrival time resolution (the rms of the
1076 relative arrival time offset) is now checked against its
1077 median and the median deviation, instead of the average
1078 plus an absolute offset.
1079
1080 - callisto: The relative arrival time offset is now calculated
1081 w.r.t. its median not w.r.t. to an artificial reference pixel.
1082
1083 - callisto: The relative time calibration now marks pixels with
1084 outlaying offset as unsuitable
1085
1086 - callisto: The interleaved relative time calibration has been switched
1087 on. The advantage is that pixels which are marked as outliers
1088 now can recover. An improvement over time is not expected, because
1089 the relative time calibration seems stable.
1090
1091 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1092 option can now be omitted.
1093
1094 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1095 or the option "-mc" is specified as default the monte carlo datacenter
1096 paths (/magic/montecarlo/...) are used if not overwritten in the
1097 dataset file.
1098
1099 - ganymed: The output files now contain run- and event-number for all
1100 events, accessible as RunNumber.fVal and EvtNumber.fVal
1101
1102 - ganymed: Added a plot showing the source position in the camera also
1103 for wobble mode
1104
1105 - ganymed: In addition to the existing task which can be setup to
1106 be executed after Cut1 a final task called "EstimateEnergy"
1107 has been added, executed before writing the final output
1108 (ganymed00000000.root). The task setup in all three cases
1109 can be choosen individually. (For all three(!) cases you
1110 can for example choose MRanForestCalc. For examples see all
1111 sponde*.rc and all ganymed*rc)
1112
1113 - ganymed: If a container "MEstimatedEnergy" is found in the
1114 parameter list (eg. because it was setup by MEstimateEnergy)
1115 it will be written to the output file.
1116
1117
1118
1119 *** Version 1.0 (2007/02/16)
1120
1121 - database: Website to plot values from the database has been added.
1122
1123 - database: The rate of spark events as found by star is now kept
1124 and the rate after cleaning is now with spark events subtracted
1125
1126 - general: The changes to the interpretation of phrases lead to
1127 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1128
1129 - general: Added example files how you can create your own calendar
1130 (eg. as christmas present) with Mars. Just run
1131 root macros/tutorials/calendar.C
1132
1133 - general: Added a possibility to display grouped data in the plotdb.C
1134 macro (and similar macros). This allows to plot hourly, nightly,
1135 weekly, monthly and yearly averages.
1136 For more details see the plotall function of the macro
1137
1138 - general: fixed the error display of the camera display. It showed
1139 wrong results.
1140
1141 - general: fixed a memory leak when reading many MStatusDisplays
1142
1143 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1144 between a spherical and a parabolic mirror
1145
1146 - callisto: We have a new pulse position check which takes the properties
1147 of the extractor automatically into account. So no need to set
1148 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1149 left is done. If possible the lo-gain extraction start and hi-gain
1150 extraction end is changed accordingly. If no proper extraction range
1151 can be set (hi-gain too much to the left) an error is raised.
1152
1153 - callisto: New swapped pixels have been found and corrected
1154
1155 - callisto: Redone the signal extraction this includes:
1156 + Unified the algorithms to extract the pedestal for all pedestal
1157 extractions done
1158 + Unification of hi- and lo-gain into one array
1159 + Unification of hi- and lo-gain extraction for Spline and
1160 Digital Filter (means now exactly the same algorithm is used,
1161 not a copy-and-pasted one)
1162 + Store pedestal subtracted data in a common place
1163 + Improved extraction algorithms. If the algorithms search a
1164 maximum but don't find one they don't return the maximum anymore
1165 + Improved the extraction such that a information for signal
1166 and time which is consistent is returned
1167 + replaced the numerical spline with a (not slower) analytical
1168 solution
1169 + Lowered the saturation limit from 250 to 245 to make sure that
1170 we are far away in all pixels from problems with the clock-noise
1171 + The start of the lo-gain extraction is calculated from the hi-gain
1172 arrival time. In case of saturation an estimation is used.
1173 + the hi-gain window was extended to slice 16. This allows extraction
1174 of very late pulses in single pixels or of huge hadron showers.
1175 + Now uses the lo-gain extraction range for pedestal extraction,
1176 not the hi-gain range in the lo-gain
1177
1178 - callisto: New hi-/lo-gain calibration constants have been produced
1179 for all periods from the statistic of the whole period. They are
1180 now used automatically depending on the periods. The old constants
1181 where deviation in avarega about 2%-3%. The constants are very
1182 stable from period to period (<<1%) except for exchanged channels.
1183 In a few cases the constants used so far were off by 1%-2% (maybe
1184 temperature effects?)
1185
1186 - callisto: To gain obsolete space we do not write the
1187 MPedestalFundamental anymore. Also calibration and bad pixel
1188 treatment is not done for it anymore because it has never been used.
1189
1190 - callisto: Fixed a bug in the seuqence handling which caused the
1191 light condition to be ignored
1192
1193 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1194 basically the same as "Cleaned" but the distribution devided into
1195 the events fullfilling a spark cut or being rejected by it.
1196 This cut can be changed from star.rc (see example inside) by
1197 the "SparkCut" directive
1198
1199 - star: Star displays now the average individual pixel-rate (IPR) versus
1200 time and the average discriminator threshold (DT) of all pixels.
1201
1202 - optim: fixed a problem with the optim-macros which was due to a bug
1203 in the new phrase parsing
1204
1205 - ganymed: To get a nice FalseSource plot (instead of the all-information
1206 debug plot displayed as a standard plot) use the context menu
1207 somewhere between the two upper plots, click on "DrawNicePlot"
1208 and enjoy the result. (It is the same context menu which contains
1209 the other options)
1210 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1211
1212 - ganymed/optim/train: The cut program, trainings- and optimization
1213 macros could run with less files found than expected from the
1214 sequence-files. No the execution is stopped in this case.
1215
1216 - ganymed: now stores the dataset in the output file with all information
1217 contained (as sequence number, sequence path, data path) so that the
1218 used dataset file can be recreated complete from the output
1219
1220 - sponde: now also allows the uasge of random forest
1221
1222 - sponde: added a plot showing the cut efficiency
1223
1224 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1225 errors (eg. effecting the collection area) because the errors of the
1226 two histograms were swapped in the calculation, which makes a difference
1227 in the case the histograms contains weighted events. Aditionally the
1228 totalarea was incorrectly taken into account, which results in too small
1229 errors, which makes a difference at low statistics were the errors
1230 or the collection area dominate.
1231
1232
1233
1234 *** Version 0.10.3 (2006/10/23)
1235
1236 - database: Implemented ObservationMode flag in websites.
1237
1238 - database: For sequences there is now also the stoptime available on the
1239 websites.
1240
1241 - database: Removed ManuallyChanged flag from sequence-info websites,
1242 as it is not needed anymore with the new sequence building algorithm.
1243
1244 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1245 Class for calculation of confidence intervals (upper limits).
1246 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1247 Please read the class instruction of TRolke for more information.
1248
1249 - general: The programs now return 0xfe if the requested resource file
1250 doesn't exist.
1251
1252 - general: Errors comming from root itself are now not output to
1253 stderr anymore but to our default (colored) log-stream.
1254
1255 - general: Changed the interface to TFormula such that now everything
1256 is parsed by TFormula, which should allow to use phrases even
1257 without paranthesis correctly parsed.
1258
1259 - callisto: replaced the AdHoc number of effective integration slices
1260 in the digital filter by an average of the correct number, averaged
1261 over all possible set of weights. This also gives correct numbers
1262 for the lo-gains which were totally wrong before.
1263
1264 - callisto: drastically reduced memory consumption by not storing
1265 all intermediate calibration results in memory anymore (we might
1266 write them into a file in the future)
1267
1268 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1269 debug plot displayed as a standard plot) use the context menu
1270 somewhere between the two upper plots, click on "DrawNicePlot"
1271 and enjoy the result. (It is the same context menu which contains
1272 the "DrawAll" option)
1273 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1274
1275
1276
1277 *** Version 0.10.2 (2006/10/15)
1278
1279 - general: changed the building of the sequence files such, that
1280 the source-/project name in case of wobble-sources is not the
1281 source/project of the first data run anymore but the new generalized
1282 wobble source/project
1283
1284 - general: Added some functions to MAstro to calculate sun and
1285 moon properties
1286
1287 - general: Added two new macros (starvisday.C and starvisyear.C)
1288 which allow to plot the visibility of several stars in one day
1289 or of one star along one year
1290
1291
1292
1293 *** Version 0.10.1 (2006/10/11)
1294
1295 - general: HTML logging output was distorted... fixed.
1296
1297 - general: Changed the writing of the sequencefiles such that only
1298 as many pedestal files as giving at least 1000 pedestal events which
1299 are nearby the first calibration run are used as pedestal runs
1300
1301 - sponde: In the calculation of the collection area(s) and the
1302 distribution for MOnte Carlo and estimated energy the error
1303 calculation was wrong because root didn't take the errors
1304 properly into account... fixed.
1305
1306
1307
1308 *** Version 0.10 (2006/10/10)
1309
1310 - general: all executables now check consistency of the root version
1311 installed with the root version used for compilation. The return
1312 code in this case is 255.
1313
1314 - general: The algorithm to build seqeunces has been redesigned
1315 completly. It is now more flexible in terms of a resource file
1316 resources/sequences.rc which can be used to partly overwrite
1317 the default algorithm and defined the important part of the
1318 algorithm. It also takes correctly into account several ways
1319 of taking wobble-data. Currently the new algorithm doesn't take
1320 the number of pedestal events anymore into account (so a sequence
1321 could have much less than 1000 pedestal events and data runs are
1322 no-more used instead)
1323
1324 - general: a lot of small changes to make the code compatible with
1325 root 5.12/00 and gcc 4.1
1326
1327 - general: Fixed some warnings thrown if more warnings are switched
1328 on in the compiler
1329
1330 - general: Added a function to MMath which returns the Median of
1331 the distribution abs(y[i]-median) but at 68:32 division instead
1332 of 50:50, which is somehow the median counterpart of the rms.
1333
1334 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1335 even if they are compressed with gzip (recommended compression
1336 is with "-1")
1337
1338 - showplot:
1339 + batch mode creation of image files now works with root 5.12/00
1340 + added support for writing bmp (though it never produces
1341 bmp which can be read by programs like xv or gimp)
1342 + added support for xml
1343 + added new option to start the display with a different size, by
1344 --display-width=nnn or --display-height=nnn
1345 + added options to define the canvas size when the display is started
1346 --canvas-width=nnn or --canvas-height=nnn
1347 the option can also be used for batch-mode conversion
1348 + added an option which automatically fits the display size to the
1349 desktop-size: --auto-size
1350
1351 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1352
1353 - merpp: allow the reports to have 1000ms due to a bug in the camera
1354 program.
1355
1356 - callisto: New swapped pixels have been found and corrected. For
1357 details see MRawRunHeader::FixAssignment()
1358
1359 - callisto: Callisto now raises an error if one of the input files could
1360 not be opened.
1361
1362 - callisto: In some rare cases it could happen that in the signal
1363 extraction of the digital filter the extractor returned nonsense
1364 results due a wrong initializion of a variable (this happens in
1365 cases in which the extracted signal is exactly zero or the
1366 digital filter couldn't slide because of a too small extraction
1367 window, which could happen in the lo-gain extraction)
1368
1369 - callisto: The lo-gains have been marked as valid in some cases
1370 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1371 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1372 smaller than the number of slices (fLoGainWindowSize) needed
1373 by the lo-gain extractor
1374
1375 - callisto: Updated absolute calibration constants (muon calibration)
1376
1377 - callisto: fixed a bug which caused the hi-gain saturation not
1378 to be handled properly in the spline (the position of the
1379 saturation was calculated incorrectly)
1380
1381 - callisto: fixed a bug which gave weird results if hi- _and_
1382 lo-gain could not be extracted properly. In some cases hi-
1383 and lo-gain have not been extracted at all and the random result
1384 got calibrated. In other cases the hi-gain was saturating and the
1385 lo-gain has not been extracted. For this a completly arbitraty
1386 scale factor was applied to the result from extracting the
1387 charge of the saturating hi-gain.
1388
1389 - callisto: improves handling of extracted signal if lo- and/or
1390 hi-gain could not be extracted properly. If no appropriate
1391 calibration of either the signal or the arrival time is possible
1392 the pixel is now markes as unsuitable instead of estimated.
1393
1394 - callisto: Fixed a problem in the spline extraction which gave
1395 weird results if the signal was extracted from the first (and
1396 highest) slice (as a workaround extraction from the first
1397 slice has been forbidden)
1398
1399 - callisto: Fixed a bug regarding the use of the QE which doesn't
1400 effect the result because the default is used anyhow.
1401 (The bug was there since 14/07/2005)
1402
1403 - callisto: Changed the default for fgLoGainStartShift to -2.4
1404
1405 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1406 factors to be always 10 for all pixels as soon as the first
1407 calibration update has happend.
1408
1409 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1410 was off by more than one slice (which gives wrong values for
1411 pixels which have saturated the hi-gain) This was a problem
1412 mainly for timing studies, not so much for the automatic standard
1413 analysis. Also the values for the Spline have been changed slightly:
1414 + Digital Filter from 1.70 to 0.95
1415 + Spline from 1.39 to 1.30
1416 The numbers were sorted out by an extensive test in the
1417 test-database.
1418
1419 - callisto: Removed the tab showing the average calibrated arrival
1420 time. It never gave useful information.
1421
1422 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1423 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1424 and both were extracted because the hi-gain was above the
1425 LoGainSwitch.
1426
1427 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1428 lo-gain pulse position (after application of LoGainOffset, which
1429 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1430 have saturated and both were extracted because the hi-gain was above
1431 the LoGainSwitch.
1432
1433 - callisto: After extensive tests a new threshold level for determination
1434 of the pulse position has been found at 50phe. This is due to the
1435 fact that for lower pulses the arrival time changes its average
1436 behaviour dramatically. It tends to the average of the extraction
1437 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1438
1439 - callisto: Added two more plots to the calibration part. The average
1440 extracted signal and the average extracted arrival time as
1441 extracted by the signal extractor (This can help debugging problems
1442 because it doesn't involve a fit)
1443
1444 - star: changed the fit for the effective on time such that initial
1445 values are calculated automatically now instead of using build
1446 in values. This makes the fit more indepedant of the underlaying
1447 rates. With a test of ~350 sequences in the test database it could
1448 be shown that the new fit gives the same result +/-1sek.
1449 The highest deviation was +5s the lowest -10s. You can now control
1450 the bahaviour with two resource values:
1451 MHEffectiveOnTime.FistBin: 3
1452 MHEffectiveOnTime.NumEvents: 12000
1453 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1454 from the resulting gamma candidates
1455
1456 - star: The Center histogram in MHHillas is now by default displayed
1457 with the colz draw-option
1458
1459 - ganymed: now produces valid error codes if failed
1460
1461 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1462 with the option "hadronness" instead of "area" or "both" if
1463 you want to use both cuts. The hadronness cut includes a fixed
1464 cut in hadronness (index 8) and a fixed cut in size (index 9).
1465
1466 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1467 the M3Long of the anti source to be not properly evaluated
1468 (actually is was evaluated as a unique random number) in case
1469 of optimization with anti-theta cut switched on. This might have
1470 lead to improper, but not necessarily wrong, optimization results.
1471
1472 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1473 how to use random forest
1474
1475 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1476 ganymed_onoff.rc. Seems to be unintentional that they were different.
1477
1478 - sponde: Since the introduction of the possibility to define a
1479 normalization energy instead of using the integral the default
1480 was not using the integral anymore but a normalization energy of
1481 1GeV. It is now the integral again.
1482
1483 - sponde: Fixed a problem in the weighting which did not allow
1484 a MC slope of -1.
1485
1486
1487
1488 *** Version 0.9.6 (2006/05/24)
1489
1490 - general: changed the binning of the azimuthal profile of the camera
1491 such that it is aligned with the 60deg boundaries.
1492
1493 - merpp: better handling of problems with the TH, TD part of the
1494 CC-REPORT for files older than 200507190 and 200412210
1495 respectively
1496
1497 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1498
1499 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1500
1501 - callisto: if an arrival time is extracted outside the fadc range is
1502 was set to the boundary before. Now a random number is assigned
1503 instead to avoid unfortunate coincidences of arrival times just
1504 by this arbitrary value.
1505
1506 - callisto: added a new option to callisto.rc which allows
1507 to set the maximum arrival time difference allowed for the
1508 badpixel algorithm to determin whether a pixels belongs to a shower:
1509 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1510
1511 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1512 to 0.9 as suggested by Stefan due to a recent study on the fraction
1513 of pixels surviving the image cleaning
1514
1515 - callisto: switched off error in case of "pulse is too much to the left"
1516
1517 - callisto: The extraction window is not adapted anymore. This means that
1518 the pulse is extracted from the full range. The draw-back is that the
1519 background (pedestal) will become slightly higher. Switching on/off
1520 the PulsePosCheck in the callisto.rc only effects filling the
1521 histograms.
1522 WARNING: If the pulse is too much to the left data is calibrated!
1523 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1524 in the database to make sure that your data is valid!
1525
1526 - star: Show also the number of stars correlated correctly by the
1527 starguider
1528
1529 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1530 than one off-source region in wobble-mode. To use it add the following to
1531 your ganymed_wobble.rc:
1532 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1533 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1534 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1535 + Cut1.ThetaCut: None
1536 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1537
1538 - ganymed: in the case the latest report is older than a default (currently
1539 one minute) and the current report will be skip the starguider
1540 correction and calibration will be reset. The maximum age can be
1541 setup from ganymed.rc by (minutes):
1542 MPointingDevCalc.MaxAge: 1.5
1543
1544 - ganymed: A first implementation showing all size-bins for the theta-sq
1545 resp. alpha-plots in a single tab automatically
1546
1547
1548
1549 *** Version 0.9.5.1 (2006/05/05)
1550
1551 - general: Added a new option "zdiff" to the Makefile which runs
1552 "cvs diff" as "make diff" would do, but with compression
1553
1554 - general: accelerated MTFillMatrix (used for eample in all training
1555 and optimization macros) by skipping some obsolete calles in the
1556 eventloop the first and second loop could be accelerated by ~20%
1557
1558 - general: Added a missing feature in the MFilterList class which
1559 prevented MFEnergySlope from working correctly in trainenergy.C
1560
1561 - general: Accelerated the random forest training and usage a bit
1562
1563 - merpp: Adapted to new raw data file format version 6
1564
1565 - merpp: fixed a problem with reading the starguider reports
1566 after 6.3.2006
1567
1568 - callisto: At some times six pixels had to be exchanged manually in the
1569 data. If the pixels to be swaped are both not found, an error was raised
1570 and calibration was stopped. Now it is assumed they are intentially not
1571 mapped and the Error has been changed to a Warning.
1572
1573 - star: Added new image cleaning based on the arrival time of the shower.
1574 The new cleaning can be accessed using the parameter "Time" instead of
1575 the the old one (like "Absolute) in the star.rc-file.
1576 Recommended parameters:
1577 + MImgCleanStd.CleanLevel1: 8.2
1578 + MImgCleanStd.CleanLevel2: 5
1579 + MImgCleanStd.CleanRings: 2
1580 + MImgCleanStd.KeepSinglePixels: No
1581
1582 - star: Simplified the calculation of the effective on time. By letting
1583 the fit start in the third bin the result should become more stable.
1584 The fit quality is now ignored for the theta-plot which is not used
1585 in the analysis later. Still better pre-cut which, for example,
1586 remove events triggered by car-light (rate changing on a short
1587 time-scale) are missing.
1588
1589 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1590 for optimization (kWeakSource) which is suggested by the Berlin
1591 people for weak sources.
1592
1593 - macros: plotdb.C:
1594 + if no dataset and no time-interval is given only sequences with
1595 an effective on-time above five minutes are plotted anymore
1596 + added a new tab "RelTime" displaying the relative on-time
1597 (effective on-time divided by the observation time)
1598
1599 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1600 the optimization became a lot faster
1601
1602 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1603 To display them just delete the pads displayed on top.
1604
1605 - ganymed: fixed a bug which could cause strange behaviour in wobble
1606 mode if no starguider information was available due to an incorrect
1607 initialization of the starguider calibration
1608
1609 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1610 be changed from within the plot. It can also be setup from the
1611 resource file using:
1612 + MHDisp.fScaleMin: 0.325
1613 + MHDisp.fScaleMax: 0.475
1614
1615 - ganymed, showplot: Fixed a problem with the fit to the off-data
1616 (HistOff) which could cause a time lag or an inifinite loop.
1617 The bug did not effect the results at all.
1618
1619 - sponde: Added a new tab showing the effective collection area after
1620 trigger (including the software trigger)
1621
1622 - sponde: MMcSpectrumWeight has a new option which allows to define
1623 the scaling factor not by the integral of the events but at
1624 a defined energy:
1625 e.g. MMcSpectrumWeight.NormEnergy: 200
1626
1627 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1628 eventloops the loop could be accelerated by ~20%
1629
1630
1631
1632 *** Version 0.9.5 (2006/03/13)
1633
1634 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1635 and added the standard Disp-parametrization
1636
1637 - macros: added a new macro datacenter/macros/plotstat.C allowing
1638 to plot statistics about the data processing
1639
1640 - macros: added a new macro to plot the muon correction coefficients
1641 versus period (macros/plot/mucal.C)
1642
1643 - showplot: path inflation for ganymed files was broken
1644
1645 - callisto: Fixed an important bug. When the number of saturating pixels
1646 were calculated the bad pixel information already available from the
1647 calibration was ignored. This yields wrong values in case pixels
1648 are broken and saturate all the time or randomly.
1649
1650 - callisto: Updated Muon calibration constants. Spline data now also uses
1651 different values for different periods
1652
1653 - star: The time-evolution shown in the effective on-time plot now displays
1654 the axis range (if there are no holes it should be similar to the
1655 effective on-time)
1656
1657 - star: Added two new image parameters:
1658 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1659 the three pixels next to the center of gravity and the size
1660 + MNewImagePar.fConcCore: The ratio of the signals of all
1661 pixels inside or touching the ellipse and the size
1662
1663 - ganymed: now stops in requested source isn't found in catalog file
1664
1665 - ganymed: Many improvements to the phi-plot in wobble mode:
1666 + with a template the ideal background is displayed
1667 + a possible camera inhomogeneity is taken into account
1668 + the anti theta cut is better supported
1669 + the phi cut is automatically calculated from the theta cut
1670 See the examples in ganymed_wobble.rc for more details.
1671
1672 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1673 times the bin-width instead of the absolute energy
1674
1675 - ganymed: New cuts for on/off and wobble mode
1676
1677 - ganymed: The smearing of the False Source plot has been increased
1678 to 0.06
1679
1680 - ganymed: The starguider calibration can now be changed from the
1681 resource file.
1682 See the examples in ganymed*.rc for more details.
1683
1684 - ganymed: added a new option for on-/off-observations
1685 MJCut.RandomSourcePosition
1686 If switched on the distribution of observation time of the source
1687 position in the camera is calculated from the on-data and randomly
1688 applied with this distrbution to the off-data.
1689
1690 - ganymed: by skipping some obsolete calles in the eventloop the
1691 first and second loop could be accelerated by ~20%
1692
1693 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1694 position in the off-data randomly according to its distribution in the
1695 on-data.
1696
1697
1698
1699 *** Version 0.9.4.3 (2006/02/13)
1700
1701 - general: Fixed a bug in most of the programs which prevented the
1702 compile date in the startup message to be displayed
1703
1704 - general: Simplified program calls. The following abbreviations
1705 are now possible:
1706 showlog callisto 55599
1707 showplot signal 55599
1708 star 55599
1709 callisto 55999
1710 ganymed 2
1711 In this cases the corrsponding root-, log-, sequence- or dataset-
1712 filename is automatically compiled using the default datacenter
1713 paths ("/magic/*")
1714
1715 - general: Fixed a long outstanding bug which made axis tick marks
1716 disappear if MDataFormula was used (eg. abs(x))
1717
1718 - general: Updated MMath with new functions to calculate the results of
1719 a exponential, logarithmic and powerlaw fits analytically.
1720
1721 - general: Updated some macros with comments:
1722 + macros/optim/optimdisp.C
1723 + macros/optim/optimenergy.C
1724 + macros/optim/optimwobble.C:
1725
1726 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1727 files) now allows adding a pre-cut like in the optimization. E.g. this
1728 is useful to perform g/h-separation cuts before training the random
1729 forest.
1730
1731 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1732 correctly assigned in the raw data assignement table. A fix to correct
1733 the assignment tabel have been implemented.
1734
1735 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1736 by 90, 180 and 270 deg.
1737
1738 - general: the macro plotdb.C now allows to highlight sequences belonging
1739 to a datset. For more details see the descritions in the macro.
1740
1741 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1742 of the display, it gave wrong results espacially for big sizes.
1743 Now the embedded canvas should always have a ratio width/height=3/2.
1744 The "Size" options have been updated with values fitting the 3/2
1745 size ratio.
1746
1747 - RanForest:
1748 + Updated the random forest classes to support also the
1749 regression method implemented by Thomas H.
1750 + added new tutorial macro how to train the random forest
1751 for energy estimation (macros/optim/rfenergyest.C)
1752 + new classes to train the random forest (still in development)
1753 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1754 + new tutorial macros for random forest training in macros/train
1755 trainenergy.C, traindisp.C, trainseparation.C
1756
1757 - mars: now allows to setup a cut in the resource file mars.rc to choose
1758 the events to be displayed, eg:
1759 Cut.Condition: {0} && {1}
1760 Cut.0: MHillas.fSize>100
1761 Cut.1: MHillas.fSize<900
1762
1763 - merpp: Made aware of the new .rep format 200510250. This includes
1764 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1765 the discriminator thresholds (MCameraTD) and the disciminator
1766 delays (MCameraTD). All of them come with the CC report and are therefor
1767 written to the CC tree.
1768
1769 - callisto: fixed a bug in the calculation of the arrival times in
1770 the Digital Filter. They were all shifted by the same amount
1771 fHiGainFirst. This caused an offset in the order of the position of
1772 the left border of the extraction window in the times calculated
1773 from high-gain and from low-gain. The bug effected only the absolute
1774 arrival times. The bug was there since 30.1.2005.
1775
1776 - callisto: Changed the ExtractionWindow for the pulse position check
1777 such that the camera inhomogeneity becomes as less as possible and
1778 comparable to the pulso position check switched off. More details
1779 on the study will be given at our result web-page.
1780
1781 - ganymed: ganymed.rc, ganymed_onoff.rc:
1782 changed to new cuts trained with 1ES1218 and Crab-data
1783 for maximum sigma*log10(excess)
1784
1785 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1786 a new option was implemented to estimate Disp (CalcDisp)
1787
1788 - ganymed: Implemented two new options which allow
1789 to overwrite the default path to search for the sequence files
1790 --ins=/magic/sequences
1791 and where to search for the image data
1792 --ind=/magic/data/star
1793
1794 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1795 dx/dy from the resource file by
1796 MSrcPosCorrect.Dx
1797 MSrcPosCorrect.Dy
1798
1799 - ganymed: fixed reading the source catalog. Only as many chars
1800 as the requested source name had were compared (If a source
1801 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1802 were requested it could happen that the coordinates of
1803 "1ES1218" were read) The source coordinates are now printed
1804 in addition to its name to the logging output.
1805
1806 - ganymed: changed the background fit in the case of a ThetaSq function
1807 from a polynomial to a exponential, this should give a big improvement
1808 for on-only analysis'
1809
1810 - ganymed/sponde: Calculation of the error of single size-/energy-
1811 bins now uses Li/Ma (5) instead of LiMa (17)
1812
1813 - sponde: Added a plot E^2*dN/dE
1814
1815 - sponde: The energy estimator plot should now show values like
1816 they are commonly used.
1817
1818 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1819 (a powerlaw with cutoff didn't work before)
1820
1821
1822
1823 *** Version 0.9.4.2 (2005/10/01)
1824
1825 - general: added new tutorial macro macros/tutorials/threshold.C:
1826 how to calculate the threshold
1827
1828 - general: added a new game. Start it from the interpreter with
1829 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1830 and MagicReversi)
1831
1832 - general: neighbor pixels in MGeoms are now sorted clockwise
1833
1834 - merpp: made aware of new format 20050829-0
1835
1836 - callisto: New scale factors from muon analysis, stored in new
1837 resource file resources/calibration.rc
1838
1839 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1840 the eventloop if something went wrong. This is necessary for the
1841 automatic processing
1842
1843 - callisto: Implemented a new treatment for the time information
1844 developed by S.Ruegamer, this should give much better response than
1845 the old very primitive algorithm. This is especially important
1846 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1847 treatment was buggy! As neighbor pixels to interpolate the
1848 arrival times always the pixels 0 to 5 were taken)
1849
1850 - callisto: In addition to the new treatment of arrival times the
1851 decision of the treatment whether a pixel contains shower
1852 information or not is used to improve the signal interpolation
1853 further. Previously interpolated pixels showed a non-zero signal
1854 do the peak searching signal extractors. Having a signal pixel
1855 beside raised the signal above the cleaning level. Thus the
1856 pixel survived cleaning to often but with a too low mean signal.
1857 By replacing empty pixels with a gaus (mean and rms from the
1858 corresponding Area entries in MPedPhotCam) this effect can
1859 be supressed.
1860
1861 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1862 got lost when the events were stored by the calibration... fixed.
1863 (This was no problem for normal image cleaning because the pixel
1864 content was artificially set to 0 not surviving standard cleaning
1865 algorithm)
1866
1867 - callisto: Fixed a bug which caused the random and peak-search pedestal
1868 extracted with an extractor to be exchanged for the first (roughly)
1869 500 events (*Extractor and *ExtractorRndm).
1870 (They were simply exchanged in callisto.cc) This bug might have been
1871 introduced in Mars 0.9.4 when the order of calculation of the two
1872 types of pedestal in callisto got exchanged. The bug only effects
1873 the first seconds of data of each sequence.
1874
1875 - star: Taking the arrival time of Muons into account the calculation
1876 of the parameters could be made independant of the noise
1877 (pedestal rms). The dependance was due to the bias of the peak search
1878 extractor. Now only a ZA dependamcy is left which is not yet fully
1879 understood.
1880
1881 - ganymed: The sequences were still not sorted correctly in any case,
1882 because they were sorted by the full qualified path name. Now they
1883 are sorted by their sequence number.
1884
1885 - ganymed: new values for the spark-event-cut
1886
1887 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1888
1889
1890
1891 *** Version 0.9.4.1 (2005/08/18)
1892
1893 - callisto: fixed some problems with the calibration in case of
1894 inteleaved events. Therefor the final and some intermediate
1895 fits are skipped which would take place on partly filled #
1896 histograms and gave wrong results or failed completely.
1897
1898 - callisto: If the intermediate finalization of the histograms
1899 calculating the mean charge of the calibration signal fails
1900 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1901
1902 - ganymed: Fixed some bugs which caused problems in On-only mode.
1903 Still the false source plot doesn't give reasonable results.
1904
1905
1906
1907 *** Version 0.9.4 (2005/08/05)
1908
1909 - general: Fixed the ZA binning. It did not correctly fit the
1910 MC binning
1911
1912 - general: Added a class to correct for the missfocussing in
1913 April (MSrcPosCorrect)
1914
1915 - general: Random Forest energy estimator should now work properly
1916
1917 - general: MHCamera now displays the profiles in deg instead of mm
1918
1919 - general: MH::SetPalette offers a lot of new palettes
1920
1921 - general: MHillas - the case of CorrXY==0 is now handled properly
1922
1923 - general: implemented the possibility to change the line and
1924 marker style of a sky-grid drawn by MAstroCatalog
1925
1926 - general: Runs in sequences and datasets are now automatically
1927 ordered (it is assumed that the order of their filenames correctly
1928 represents the order of observations) to ensure correct reading
1929 of the subsystem data
1930
1931 - general: Runs cannot be added to a sequence twice anymore. Also
1932 Sequences cannot be added twice anymore to a dataset.
1933
1934 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1935 It gave wrong results by 1./2pi
1936
1937 - showplot: got a new option to start a root interpreter, too
1938
1939 - mars: now displays a rough estimate of Disp and the third moment
1940
1941 - mars: now displays the event time MTime if available
1942
1943 - mars: show muon parameters graphically
1944
1945 - mars: now the file to open can be given as commandline
1946 argument
1947
1948 - merpp: Added support for new arehucas version >= 200507190
1949 implementing values for three temperature sensors in the
1950 counting house (MCameraAUX) and the name of the HV settings file
1951 (MCameraHV).
1952
1953 - merrp: Also fixed some problems with wrong versions numbers stated
1954 by arehucas and implemented some fixed for old versions (<200407070)
1955
1956 - callisto: MCalibrationHiLoCam can now be printed from its context
1957 menu, eg in the TBrowser
1958
1959 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1960 - 1.39 (MExtractTimeAndChargeSpline)
1961 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1962 This is important mainly for timing studies.
1963
1964 - callisto: Changed limits in MHCalibrationChargeCalc from
1965 - -100.125 to -98 (fgChargeHiGainFirst)
1966 - 1899.875 to 1902. (fgChargeHiGainLast)
1967 - -100.25 to -99 (fgChargeLoGainFirst)
1968 - 899.75 to 901. (fgChargeLoGainLast)
1969 Introduced new limits:
1970 - fgNumLoGainBlackoutLimit: 0.05
1971 - fgLoGainBlackoutLimit: 3.5
1972 - fgLoGainPickupLimit: 3.5
1973
1974 - callisto: The handling of automatic weights for the digital filter
1975 has been improved. There are now new calibration weights special
1976 for Monte Carlo calibrations.
1977
1978 - callisto: Updated Muon scale with latest results (1% difference
1979 for most data, 5% for Mar/Apr'05)
1980
1981 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1982 was saturated and the blackout-events in the low-gain exceed the
1983 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1984 This excludes those pixels which have a saturating high-gain
1985 channel, but the low-gain switch does not switch often enough
1986 to make the distribution reliable.
1987
1988 - callisto: fix a bug counting the number of saturated events. Up to now,
1989 the number of saturated slices was counted (which is one for a not too
1990 high number), but for some (pathological) pixels, many more slices
1991 saturated and produced wrong limits.
1992
1993 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1994 + MCalibrationRelTimeCam.CheckFitResults: Yes
1995 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1996 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1997 + MCalibrationRelTimeCam.CheckOscillations: Yes
1998
1999 - callisto: introduce max. number of events for intercalibration,
2000 the rest gets skipped. Default: 4096
2001 The calibration causes too many un-reliable pixels if more
2002 than about 5000 events are treated (@500 Hz) because of the
2003 mode hopping of the VCSels. However, in the past, some
2004 calibration runs have been taken (erroneously) with more
2005 than 5000 events, especially the intensity scans where
2006 a good precision is needed.
2007
2008 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2009 photo-electrons for the spline extractor by 1-2% (correctly).
2010
2011 - callisto: The intercalibration is now done using a full f-factor
2012 method instead of a simple update. This makes things slower but
2013 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2014 changes.
2015
2016 - callisto: MPedestalY3 now uses the same extraction range as the data
2017 as calculated by MPedestalY2
2018
2019 - callisto: A check of the fraction of allowed unsuitable (10%) and
2020 unreliable (30%) pixels has been addded when the conversion is
2021 calculated from interleaved events
2022
2023 - star: fixed a bug which caused MEffectiveOnTime containers not to
2024 be written. In the worst case they were skipped almost all, in the
2025 best case they were all ok. It depends on how often the new value
2026 was assigned just with an event which was skipped later by another
2027 task
2028
2029 - star: new histograms MHPointing and MHRate
2030
2031 - star: New tab (Currents) displaying the time evolution of the mean
2032 DC currents
2033
2034 - star: New tab (MeanRms) displaying the time volution of the mean
2035 Pedestal Rms
2036
2037 - star: Output now contains MReportStarguider
2038
2039 - star: Improved muon analysis. Due to the absense of a constant
2040 for the gaus fit for arc width and the fact that the arcwidth
2041 plot was a histogram instead of a profile the resulting psf
2042 became pedestal rms dependant
2043
2044 - ganymed: added new plot (MHPhi) for wobble mode as described in
2045 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2046
2047 - ganymed: corrects now (correctly?) for the misspointing in
2048 May/April 05
2049
2050 - ganymed: Two new default templates for ganymed.rc are avilable:
2051 ganymed_onoff.rc and ganymed_wobble.rc
2052
2053 - ganymed: The first version of MFMagicCuts has been released
2054
2055 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2056
2057 - ganymed, sponde: There are two new options to determin the number
2058 of bins for the signal region (NumBinsSignal) and the number of
2059 total bins (NumBinsTotal) in the MHThetaSq histogram
2060
2061 - ganymed: optimized palettes for MHDisp
2062
2063 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2064 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2065 sqrt(2) to large
2066
2067 - ganymed: The false source plot (MHDisp) is now based on Disp
2068 and a background model determined in the first loop is
2069 subtracted
2070
2071 - ganymed: MFMagicCuts are now available in the cvs. The correct
2072 solution for the disp ambiguity problem is now calculated using
2073 the third moment. The third moment cut therefor is skipped.
2074
2075 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2076 already determined by the third moment along the major axis and
2077 so its actual sign is aligned along the major axis of the shower.
2078
2079 - ganymed: If starguider data is available it is taken into account
2080 when calculating the source position. This is especially important
2081 for wobble data at high zenith angles and culmination data.
2082
2083 - ganymed: If available the starguider data is taken into account as
2084 good as it is possible without a starguider calibration. To switch
2085 it off add
2086 MPointingDevCalc.MaxAbsDev: -1
2087 to your ganymed.rc
2088
2089 - sponde: the zenith angle distribution is now weighted instead of
2090 choosen by default. This gurantees higher statistics in the highest
2091 and lowest energy bins. To switch this behaviour off use...
2092
2093 - sponde: now automatically displays the energy threshold
2094
2095
2096
2097 *** Version 0.9.3 (2005/06/03)
2098
2099 - general: MMcEvt now derived from MMcEvtBasic which should
2100 have no influence on compatibility with older camera files
2101
2102 - general: Implemented a new option to MReadReports which allows
2103 to force reading of the first event of some trees (eg. Drive-tree)
2104 before any other tree.
2105
2106 - general: Made a fix to MPointingPosCalc which assumes that the
2107 run-type is real-data if Process is called before ReInit, such
2108 that also the very first Drive-events in a run are treated
2109 correctly.
2110
2111 - shoplot now displays the filename in the title bar of the window
2112
2113 - merpp: new options: --auto-time-start --auto-time-stop which
2114 allow to cut updating with slow-control at the start- or
2115 (previousle --auto-time only allowed: and) stop-time of
2116 the run stored in the runheader.
2117
2118 - callisto: changed default of fgFallTimeHiGain in
2119 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2120 already set as default in callisto_Dec04Jan05.rc
2121
2122 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2123 now changes the filename for new weights automatically for
2124 cosmics, MC and for different calibration colors.
2125
2126 - callisto: a problem with the order of some code cause the
2127 name of the weights file in MPedestalY2 to be ignored.
2128 Wrongly the calibration_UV weights were used instead
2129 of the cosmics weights set in callisto.rc.
2130
2131 - callisto: should allow ct1 pulser data when the color is
2132 explicitly set also for pretty new runs
2133
2134 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2135 to introduce an additional scale factor (should be around 1)
2136 to adapt for slight deviations in different extractors from
2137 the MC calibration. For MC calibrations the scale factor
2138 is fixed to 1
2139
2140 - callisto: MFCosmics should handle very high signals a bit
2141 more accurate now
2142
2143 - callisto: when calculating the mean pedestal rms for different
2144 pixel sizes or sectors also kUnsuitableEvt is now taken into
2145 account - not only kUnsuitableRun
2146
2147 - callisto: '-raw' option is now the default
2148
2149 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2150 This has the advantage that mean values in the calibration (eg
2151 arrival times) are calculated more accuratly.
2152
2153 - callisto: In the resource file callisto_Dec04Jan05.rc
2154 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2155
2156 - callisto: new Hi-/Lo-Gain intercalibration constants
2157 hilocalib_sp1.root and hilocalib_sp1_mc.root
2158
2159 - callisto: changed default for MJPedestalY2.MaxEvents
2160 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2161
2162 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2163 has changed from 9.0 to 6.0. This is necessary to exclude two very
2164 ringing pixels in September which - when kept - destroy the image
2165 cleaning around them (Markus G.)
2166
2167 - callisto: (!) The Muon analysis of all data taken so far has
2168 suggested that different extractors give slightly different
2169 absolute results after calibration, due to there different
2170 handling of the calibration- and cosmics pulse shape. Although
2171 the over all calibration seems to be a bit to pesimistic (or
2172 the MC seems to be a little bit - 3-5% - too much attenuated).
2173 There for correction factors have been introduced which correct
2174 the calibration constants by
2175 0.956937799 for Digital Filter (callisto.rc)
2176 and
2177 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2178 calibration. The main advantage is, that both data types can
2179 be easily analysed together and compared to the same MC sample.
2180 The factors are choosen such, that the reference is now a
2181 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2182
2183 - star: fixed a bug which caused the first bin of the histograms
2184 vs time to disapear in PostProcess. This gave wrong results
2185 on the screen. The output and all following programs not
2186 directly accessing the histograms haven't been affected
2187
2188 - star, ganymed: Made sure that always the first Drive-tree event
2189 is read and Processed before the first data event was read.
2190
2191 - ganymed: implemented the possibility to replace the standard
2192 false source plot with a different one. For example: If
2193 you want to use a Disp based FS plot use the resource:
2194 NameHistFS: MHDisp
2195 For details about the requirements of these plots look
2196 at the corresponding classes
2197
2198 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2199 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2200 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2201 case MAlphaFitter is setup correctly. For On-Only optimization
2202 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2203 RunOn() instead of Run(). For energy estimation MJOptimize
2204 has been replaced by MJOptimizeEnergy
2205
2206 - sponde: The input MC spectrum can now be weighted to fake a
2207 different spectrum. This is done via MMcSpectrumWeight. For
2208 more details see the class description and sponde.rc
2209
2210 - sponde: The paremeter comparsion plots are not scaled by
2211 their entries anymore. Instead the MC plot is scaled by using
2212 the result spectrum of the analysis. If the input MC spectrum
2213 and the result spectrum has different slopes the absolut
2214 normalization is normally wrong.
2215
2216
2217
2218 *** Version 0.9.2 (2005/05/20)
2219
2220 - general: Changed the default paths for calibrated data and image
2221 files. (The implemented access to these files doesn't yet exist)
2222
2223 - general: support for MRunIter has been removed from the job classes
2224 (use the setter functions of MSeqeunce instead)
2225
2226 - general: ProcessFile has been renamed to Process in all job classes,
2227 because ProcessFile is missleading
2228
2229 - general: The storage of the palette in MHCamera is now possible
2230
2231 - general: new bits describing unsuitable and unreliable pixels have
2232 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2233 kDeadPedestalRms, kFluctuatingArrivalTimes
2234
2235 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2236 versions newer than V200404070
2237
2238 - general: support for cc file versions newer than V200504130. Added
2239 support for active loads (MCameraActiveLoad) and central pixel
2240 (MCameraCentralPixel)
2241
2242 - general: added new histograms for image parameters versus size
2243 (MHVsSize)
2244
2245 - general: The eventloop now automatically calls PrintStatistics
2246
2247 - Status Display: Improved support for printing:
2248 + A default can now be set in .rootrc (for more details see
2249 MStatusDisplay::PrintPS)
2250 + A print dialog is opened so that printer and command line
2251 can be canged
2252
2253 - showlog: improved such that it handles different verbosity levels
2254 more accurate now. This mean you can suppress output when
2255 using showlog.
2256
2257 - showplot: improved
2258 + The new graphics formats have been implemented
2259 (pdf, svg, png, jpg and xpm)
2260 + Implemented an interface for printing. Because you can change
2261 the printing command from the command line you can use all
2262 the nice postscript tool. To print a booklet for example call:
2263 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2264 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2265 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2266
2267 - callisto: fixed a bug in the recognition of the calibration bit
2268 pattern. Concerns only intensity calibration. (The strength of the
2269 intensity has been updated in some cases)
2270
2271 - callisto: add a filter against PIN Diode events when running over
2272 calibration runs since some of the recent calibration runs have
2273 been taken with Pin Diode.
2274
2275 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2276 39943, 44833 in the calibration (MCalibColorSet)
2277
2278 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2279 been set to 1e-18 in callisto_Dec04_Jan05.rc
2280
2281 - callisto: in callisto_Dec04Jan05.rc: set value for
2282 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2283 statistics for the calculation of the mean pulse time
2284 of the cosmisc
2285
2286 - callisto: the charge limit in the calibration has been raised
2287 from 2.5 to 4.5
2288
2289 - callisto: new setup read from callisto.rc
2290 + MCalibCalcFromPast.fNumEventsDump
2291 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2292 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2293
2294 - callisto: MExtractTimeAndChargeSpline extractor:
2295 + The integration ranges were shifted by 0.2 FADC slices to the right.
2296 + unreliable handling of floating point values caused different
2297 results on different platform or with different compiler options:
2298 The new algorithm is numerically exact and more accurate because
2299 it doesn't calculate the integration position by multiple times
2300 adding the step-size (which results in numerical uncertanties
2301 exspecially if multiplied with large numbers)
2302 + A lot of fixes have been introduced which effects integrating the
2303 spline at the edges of the valid range. In this case any memory
2304 was randomly accessed. This behaviour can be tested replacing
2305 all MArrayF by TArrayF which perform a range check (but of course
2306 they are a lot slower)
2307 ! No result obtained with the Spline before can be trusted! Due to
2308 random memory access it might by completely random!
2309
2310 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2311 + extraction range in the high gain to 4.
2312 + weights file to cosmics_weights46.dat
2313
2314 - callisto:
2315 + introduce the check for fluctuating arrival times.
2316 + set charge limit to from 2.5 to 4.5
2317 + introduce asymmetric exclusion due to "deviating number of phes":
2318 Default: -9.0 +4.5
2319 + make deviating number of phes unsuitable (see David's findings).
2320
2321 - callisto: fixed the display of unsuitable pixels. The old change
2322 to a real profile in MHCamera broke it.
2323
2324 - callisto: The cosmics filter is used in MJCalibration now
2325 independant of the pulser color (formaly it was used only for
2326 CT1-pulser data). The threshold of number of max empty pixels
2327 has been raised from 2% to 5% in MJCalibration. The maximum
2328 fraction of rejected event is 50% otherwise the calibration has
2329 failed. The filter now ignores unsuitable pixels.
2330 Setup the filter from callisto.rc using "ContCosmics"
2331 (see MFCosmics::ReadEnv)
2332
2333 - callisto: changed default for fgOffsetFromLogain back
2334 from -2.8 to -1.8 in digital filter.
2335
2336 - callisto: for the common extractors
2337 + MExtractFixedWindow
2338 * MExtractTimeAndChargeSlidingWindow
2339 * MExtractTimeAndChargeSpline
2340 * MExtractTimeAndChargeDigitalFilter
2341 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2342 and fResolutionPerPheLoGain
2343
2344 - callisto: Updated the hi-/lo-gain intercalibration constants
2345 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2346 hilocalib_df6.root
2347
2348 - callisto: The default lo-gain extraction window for the
2349 MExtractTimeAndChargeSlidingWindow extractor has been increased
2350 from 6 to 8 to take the stretch of the pusle into account
2351
2352 - callisto (!!!): fixed an important bug in the setting of the
2353 incoming pedestal pointer to the signal extractor extracting
2354 pedestals. This bug caused the pedestals not to be subtracted
2355 correctly in the calibration afterwards. The effect was about 10%
2356 too high conversion factors for the digital filter and the spline
2357 and more than 40% for the sliding window.
2358 The bug existed since end of February! (Markus G.)
2359
2360 - star: added muon support to star. A new tab "MHMuonPar" is
2361 displayed. The lower right plot is an estimate of the point spread
2362 function. A reference value is displayed. To get the real PSF
2363 you must compare with MC. The setup for the muon analysis
2364 is done in star.rc. More informations can be found in
2365 MHSingleMuon and MHCalibParCalc
2366
2367 - star: The weather data is now displayed in star
2368
2369 - star: MEventRateCalc handles the calculation of the event rate more
2370 accurate now in case of the start of a new run inside a sequence
2371
2372 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2373 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2374 changed only minimally
2375
2376 - ganymed: (MJCut and MJOptimize) now displayes the number of
2377 excess events versus size. The energy estimation is done in
2378 MJSpectrum (sponde)
2379
2380 - ganymed: got support for using other variables than Alpha, eg. Theta.
2381 Therefor you need a class deriving from MHAlpha which supports
2382 this variable (one is already existing: MHTheta, which is now the
2383 default in ganymed). It is setup through ganymed.rc
2384
2385 - added a full featured spectrum program (sponde) which reads
2386 ganymed output and monte carlos and compiles a spectrum
2387
2388
2389
2390 *** Version 0.9.1 (2005/04/14)
2391
2392 - Fix bug on the arrival time reconstruction when using Digital
2393 Filter (in some marginal cases (10%) times were reconstructed shifted
2394 by 0.2 slices)
2395
2396 - all executables now return 2 where in previous versions -1 has
2397 been returned (gave problems with shell-scripts)
2398
2399 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2400 also done with a intercalibration input file
2401
2402 - a bug in the time fine adjustment of the digital filter has been fixed
2403
2404 - a lot of small fixes to calling TPad::Divide with a margin==0
2405
2406 - MStatusDisplay now shows the memory usage
2407
2408 - added a memory leak statistic after the eventloop
2409
2410 - MHadronness replaced by MParameterD
2411
2412 - MEnergyEst replaced by MParameterD
2413
2414 - wobble mode can now be switched on from the data-set
2415
2416 - switched on bad pixel detection for a pedestal level
2417 which is more than 5 times the variance
2418
2419 - Fixed default paths to be correct for the new data center
2420
2421 - Fixed handling of drive data. The pointing position in now
2422 copied to MPointingPos inside star for real and MC events
2423
2424 - made sure, that the sequences in a dataset are sorted by
2425 their number to ensure the correct synchronization
2426
2427 - added all resource files necessary to handle spline extraction
2428 of signal for the late 2004 and the early 2005 data
2429
2430 - update the reference lines for the december data
2431
2432 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2433 This is important for the Dec. and Jan. data where the calibration
2434 pulse position changes much.
2435
2436 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2437 filter. This corrects only an defective extraction of the MC at
2438 low-gain signals lower than 90 phes.
2439
2440 - fixed some slowdown in calibrating data with interleaved events from
2441 Jan and Dec. As a workaround made the pretty palette the default.
2442 The inverse Deep Blue Sea has a bug which slows down long calibration
2443 runs a lot.
2444
2445 - implemented new values from new starguider report as defined
2446 in TDAS00-07 V7.1 (eg SkyBrighness)
2447
2448 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2449 in starguider report (If you merpp the same reports with this version
2450 you'll get the correct units (arcmin) but a different result
2451 than with old versions (wrong units))
2452
2453 - Now the status display can also write PNG, JPEG and XPM (other file
2454 formats are still unsupported by root)
2455
2456 - added a lot of scripts and macros in directory datacenter used
2457 for automatic processing
2458
2459
2460
2461 *** Version 0.9 (2005/03/23)
2462
2463 - Calibration is now done autmatically into photo-electrons like
2464 decided by the Collaboration Board
2465
2466 - Reference lines in the display can be read from resource file
2467
2468 - Interlaced calibration events can be handled by callisto
2469
2470 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2471 and applied in callisto.
2472
2473 - class MJCalibTest can be called by callisto
2474
2475 - callisto can now run with three data types: rawdata, rootdata, MC
2476
2477 - added two classes mreport/MReportStarguider.cc and
2478 mreport/MReportStarguider.h for implementing starguider-data
2479
2480 - the output of merpp-update now contains starguider information:
2481 MReportStarguider and MTimeStarguider
2482
2483 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2484 values were lower than they should. This was more visible for high
2485 energy (Size) events.
2486
2487 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2488
2489 - added a new loop to callisto to support the correct extraction of
2490 the pedestal and pedestal rms through the signal extractor
2491
2492 - added class to perform fourier tranformation of a hexagonal structure
2493 (MHexagonalFT)
2494
2495 - added class to perform fourier tranformation of a hexagonal structure
2496 in a tasklist (MHexagonalFTCalc) example: hft.C
2497
2498 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2499 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2500 small pixels, example: extendcam.C
2501
2502 - added possibility to write data to memory (TTree) using MWriteRootFile
2503
2504 - added possibility to read a TTree stored only in memory by MReadTree
2505
2506 - new classes to deal with the interleaved calibration events:
2507 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2508
2509 - implemented filters to callisto to skip calibration events
2510
2511 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2512 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2513 the slices by statistics
2514 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2515 signal extractor without randomization
2516 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2517 with the signal extractor with randomization (extraction window is
2518 randomly fixed)
2519 The three kind of pedestal is not yet implemented (for speed reasons) as
2520 long as nobody really needs it:
2521 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2522 extracted with the signal extractor with randomization
2523
2524 - callisto now finds the pulse position in the data automatically
2525
2526 - implemented data reduction in calibrated data by reducing the precision
2527 of the stored floating point values (pedestal, rms and signal) to
2528 roughly 0.5%
2529
2530 - fixed showplot to make file format conversion (eg. converting a
2531 status display stored in a root file into a postscript file) in
2532 batch mode possible:
2533 showplot -b --save-as-ps[=outfile.ps] infile.root
2534
2535 - Allow class names as part of filter rules, eg
2536 (MFSupercuts) && (MHillas.fSize>100)
2537
2538 - fixed a lot of stuff to allow all programs to process MonteCarlo
2539 camera files.
2540
2541 - enhanced possibility to debug reading of resource file
2542
2543 - MDataChain should handle priorities of operator more
2544 accurate now
2545
2546 - completely revised the container in which the signal is stored
2547 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2548 * the new implementation is faster and
2549 * needs less storage space
2550
2551 - FIRST version which can process Monte Carlos through the
2552 whole chain of programs (callisto, star, etc)
2553
2554 - implemented new image parameters for the border length of
2555 the shower image (MNewImagePar2)
2556
2557 - implemented wobble-mode in ganymed
2558
2559 - new class (MJOptimize) taking care of all optimization processes
2560
2561
2562
2563 *** Version 0.8.6 (2004/10/05)
2564
2565 - New combined signal and time extractor
2566 MExtractTimeAndChargeDigitalFilter
2567
2568 - The Report for the trigger section in the CC run summary has been
2569 updated, and now the IPRs (Individual Pixel Rates) are available.
2570
2571 - new macros for database interaction: filldotrun.C, filldotrbk.C
2572
2573 - added new program which can convert colored output which was redirected
2574 into a file back into colored text (for example to display it with
2575 more): showlog
2576
2577 - added new program to display an MStatusArray of plots (stored with
2578 MStatusDisplay) from a file: showplot
2579
2580 - Added support for Sequences (MSequence). Sequences are blocks of run
2581 files containing the same calibration and belonging to the same
2582 source
2583
2584 - Added a new task (MTaskEnv) which can be used in setup files to switch
2585 between different tasks (for example to choose a signal extractor)
2586
2587 - Implemented automatic file splitting in MWriteRootFile
2588
2589 - After image cleaning an island index is assigned to all used pixels.
2590 The index corresponds to the order of the islands in size.
2591
2592 - added a cleaning which takes signal height _and_ arrival time into
2593 account: probability cleaning (for more details see MImgCleanStd)
2594
2595 - added a cleaning which takes takes the absolute number of photons
2596 times the area ratio as cleaning level
2597 (for more details see MImgCleanStd)
2598
2599 - Changed calculation of image parameters such, that it can be done
2600 for all used pixels or the pixels with a defined island index only
2601
2602 - implemented new image parameters displaying the number of islands,
2603 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2604
2605 - event display in executable changed to support also calibrated files
2606 (done with MJCalibrateSignal)
2607
2608 - added program doing the calibration and the signal extraction
2609 and signal calibration: callisto Most part of the setup is done
2610 by a resource file: callisto.rc
2611
2612 - implemented support for pixels with negative IDs (Raw file format
2613 version 4)
2614
2615 - implemented an new option in merpp (--auto-time) to get the time
2616 range for cc and/or caco data from the run header of the raw data
2617
2618 - New star-program (star and MJStar). Taking calibrated data from
2619 callisto/MJCalibrateSignal as input. The setup is done through
2620 a resource file: star.rc
2621
2622 - Added possibility to setup the eventloop in the mars-executable
2623 Camera Display by a resource file: mars.rc
2624
2625 - The the mars-executable Camera Display can now also read
2626 calibrated data files written by callisto/MJCalibrateSignal
2627
2628 - Added a new class which can calculate the source position in
2629 the camera from a pointing model known to be correct and
2630 the pointing model used for observations (MSrcPosFromModel)
2631
2632 - added a new version of the class calculating the effective on-time
2633 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2634 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2635 MHTimeDiffTheta.
2636
2637 - added the possibility to count how often a signal is above (or
2638 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2639 can replace MHTriggerLvl0)
2640
2641 - added ore convinient ways to set the axis-titles of your histograms
2642 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2643 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2644
2645
2646
2647 *** Version 0.8.5 (2004/08/06)
2648
2649 - new Signal Extractors: MExtractFixedWindowSpline
2650 and MExtractAmplitudeSpline
2651
2652 - implementes interleave in merpp to be able to merpp parts of a file
2653
2654 - implemented force-functionality to merpp
2655
2656 - star display to display star catalogs (MAstroCatalog)
2657
2658 - star display to 'mirror' stars to the camera (MAstroCamera)
2659
2660 - implemented a new cleaning option which allows cleaning scaled with
2661 the real ratio of the rms depending on the pixel size, not only the
2662 square root of the pixelsize (MImgCleanStd, MCameraData)
2663
2664 - removed obsolete MBlind* classes
2665
2666 - Signal extractor taking the AB flag into account implemented (this makes
2667 an odd number of slices for signal extraction possible
2668 (MExtractSignalABcorr)
2669
2670 - implemented a class extracting the pedestal from the raw-data (events)
2671 itself using empty lo-gain (MpedCalcFromLoGain)
2672
2673 - Added mean values to MPedPhotCam
2674
2675 - Added Makefile for Darwin (this OS is NOT officially supported!)
2676
2677
2678
2679 *** Version 0.8.4 (2004/04/19)
2680
2681 - new fast arrival time extractor using cubic splines:
2682 MExtractTimeFastSpline
2683
2684 - implementes multi-argument support in MDataChain
2685 ("pow(a, b)")
2686
2687 - implemented double reference support in MDataChain
2688 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2689
2690 - added support in MF for expressiond like
2691 "MHillas.fWidth<2*<MHillas.fLength"
2692
2693 - MDataChain is now able to support variables like [0], [1], ...
2694 which can be used in fit functions as parameters. The interface
2695 is implemented through the new virtual function
2696 MParContainer::SetVariables
2697
2698 - added new class MArrivalTimeCam/MArrivalTimePix:
2699 Storage containers to hold the ArrivalTime of the camera/pixel
2700
2701 - added new classes for the calibration of relative arrival times:
2702 MCalibrationRelTimePix and MCalibrationRelTimeCam
2703
2704 - added new classes to extract the signal of the blind pixel and the
2705 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2706
2707 - added new classes for the bad-pixels treatment (MBadPixels*)
2708 which are more powerfull than the old ones (MBlindPixel*)
2709 and will replace them.
2710
2711 - added filter against cosmics: MFCosmics
2712
2713 - added new class MArrivalTimeCalc2:
2714 Calculates the arrival time as the signal weighted mean of the time
2715 slices in the maximum window
2716
2717 - added a new macro call pointspreadfucntion.C that fits with a 2D
2718 gaussian the DC spot for an star. It gives you the RMS of
2719 the PSF and the center of the star, very useful for misspointing
2720 studies.
2721
2722 - added support for multi-telescope camera files. Added classes
2723 MStereoCalc and MStereoPar, classes to calculate and store shower
2724 parameters calculated from the data of two telescopes, for the MC
2725 studies regarding the MAGIC clone.
2726
2727 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2728 MC data calibrated in photons instead of ADC counts.
2729
2730 - added three macros to show the calibration and analysis chain of
2731 MC data. The macro starmc.C does both calibration and analysis, producing
2732 an output containing Hillas parameters for each event. The macro
2733 mccalibrate.C does just the calibration and writes out a file containing
2734 pixel information in photons instead of FADC data. The macro starmc2.C
2735 reads in such a file and produces an output with Hillas parameters.
2736
2737 - added MPedPhotCalc to compute pedestals in units of photons, see
2738 macro pedphotcalc.C
2739
2740 - added all class to perform the calibration, see macro calibration.C
2741
2742 - added class MFFT to perform Fast Fourier Transforms
2743
2744 - added class MSimulatedAnnealing to perform simulated annealing
2745 minimizations
2746
2747 - added new macro bootcampstandardanalysis.C which holds the skeleton
2748 of the analysis chain discussed in the december bootcamp.
2749
2750 - added support for DAQ raw data file format V2
2751
2752 - implemented an arbitrary time stamp for the events from raw-data
2753 files with file version<3. It is calculated from the run number,
2754 the date of start and the FADC clock tick from the first module
2755
2756 - implemented the correct decoding of the event time-stamp
2757 coming from the DAQ for raw-data files with file-version>2
2758
2759 - added a new classes storing the pedestals in units of photons:
2760 MPedPhotPix, MPedPhotCam
2761
2762 - added support for DC current files from the camera control
2763
2764 - added support for start- and stop-time when merpping report files
2765
2766 - added MReportCC storing the weather data from the CC-REPORT
2767
2768 - added class to fill trainings and test matrices (MTFillMatrix)
2769
2770 - added a filter performing a software trigger (MFSoftwareTrigger)
2771
2772 - Added classes to perform parts of the standard analysis (Jobs):
2773 + MJPedestals
2774 + MJCalibration
2775 + MJExtractSignal
2776 Note: All of them are preliminary!
2777
2778 - Added Iterator to iterate over files giving only the run-number
2779
2780 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2781 the evolution of a sector vs time
2782
2783
2784
2785 *** Version 0.8.3 (2003/12/05)
2786
2787 - adapted Random Forest classes to allow the use with MC
2788 multi-telescope files which can be produced with the coming
2789 camera version 0.7.
2790
2791 - added classes to read and interprete central control report files
2792 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2793
2794 - enhanced merpp (the executable) to support .raw and .rep files.
2795
2796 - added classes for light calibration (MCalibration* and
2797 MHCalibration*) by Markus Gaug. Further work has to be and will
2798 be done soon.
2799
2800 - Added a preliminary 'synchronizer' (MReadReports) which will
2801 replace MReadMarsFile as soon as it is finished.
2802
2803 - Added a tutorial macro demonstrating how report files are merpped
2804 and how they can be read from the root file in the correct order
2805 of time (readrep.C)
2806
2807 - Added a generalized histogram (similar to MH3) called MVsTime
2808 which allows to plot variables (or rules - MDataChain - of
2809 variables) vs time. For an example have a look at tempvstime.C.
2810
2811 - Changed the name of the event trees:
2812 + Events --> Events
2813 + PedEvents --> Pedestals
2814 + CalEvents --> Calibration
2815
2816 - changed name of MTime in the event trees from MRawEvtTime to MTime
2817
2818 - added displaying the sector indices to the mars event display
2819
2820 - Magic Online Analysis (MOnA) implemented in a first version
2821 (see mona.cc, MOnlineDump and MOnlineDisplay)
2822
2823 - added classes to calculate event rate
2824 (preliminary: MEventRateCalc, MEventRate)
2825
2826 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2827
2828 - added classes dealing with the telescope pointing position (MPointing*)
2829
2830 - implemented the 'final' Mars time stamp based on some experiences with
2831 the new 'Synchonizer'
2832
2833
2834
2835 *** Version 0.8.2 (2003/11/10)
2836
2837 - accelerated standard analysis by a factor of 6-8 ...
2838 + doing precalculations in MGeomCam for the pixel area ratio
2839 + creating a look up table for the single pixels in MCerPhotEvt
2840
2841 - added task to calculates weights in case you want to 'change'
2842 the energy spectrum of a monte carlo file
2843 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2844
2845 - added a new executable star which implements the
2846 star.C macro as precompiled executable. Currently a flexible
2847 setup is not possible, but a 'input card' setup will follow.
2848
2849 - Starting to implement Multi-Telescope-Support based on the
2850 upcomming camera version 0.7. The base for a general support
2851 is implemented and the star-functionality is proven to work.
2852
2853 - Replaced Event-Display in and Camera-Display in the Mars GUI
2854 executable by a more convinient display base on MStatusDisplay.
2855
2856 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2857
2858
2859
2860 *** Version 0.8.1 (2003/10/20)
2861
2862 - added signal subtraction for pure on data by means of fitting
2863 the background in the off region or by performing a combined
2864 signal/background fit. Provides necessary histograms for
2865 obtaining energy spectra and a light curve.
2866
2867 - added classes to perform and study the selection of the
2868 2nd Level Trigger on MC data (example in triglvl2.C macro)
2869
2870 - added pedestal calculation
2871
2872 - implemented "democratic cleaning" (tail cut value proportional
2873 to pixel area) according to Wolfgang's suggestion.
2874
2875 - added Sigmabar treatment (calculation and basic histogramming)
2876
2877 - added basic routines to apply padding
2878
2879 - added first implementation of MARS-based source visibility plotter
2880 (needs to be linked against slalib, preliminary version)
2881
2882 - enhanced functionality of data chains: random numbers, conversion
2883 functions and access to MHMatrix objects
2884
2885 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2886 numbers under certain circumstances (runs with 0 events included)
2887
2888 - fixed a bug in the general filter MF (didn't work on some systems
2889 at all)
2890
2891 - fixed a bug in chaining files, which caused the analysis to crash or
2892 ignore files
2893
2894 - implemented more geometry classes describing the parameters used
2895 to simulate the PMT camera
2896
2897 - added new Monte Carlo classes containing the setup of the different
2898 programs in the MC chain.
2899
2900 - added a (preliminary) general task to evaluate chi-square of a given
2901 parameter in an eventloop.
2902
2903 - first implementation of a container describing the observatory
2904 location (Long, Lat, etc)
2905
2906 - added Random Forest - method for g/h-separation
2907
2908 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2909 (this means, that it is compiling, but not yet fully tested)
2910
2911 - added a new status display which can show the present status
2912 of histograms while an eventloop is running (MStatusDisplay,
2913 an example can be found at status.C)
2914
2915 - reorganized directories:
2916 classes describing the image --> mimage
2917 classes containing Monte Carlo Histograms --> mhistmc
2918 classes for Random Forest method --> mranforest
2919
2920 - added (event-)weights to fill histograms
2921
2922 - colors in logging output to screen
2923
2924 - changes to the Image Parameter declaration:
2925 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2926 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2927 + MHillasExt now derives from MParContainer instead of MHillas
2928 --> Files written with the old definition are more or less unreadable
2929
2930 - reading of reflector files
2931
2932 - display data from reflector files in the camera
2933
2934 - implemented currents (and display them in the camera)
2935
2936 - logarithmic scale in camera
2937
2938 - added class to iterate through directory contents (MDirIter)
2939
2940
2941
2942 *** Version 0.8 (2002/11/18)
2943
2944 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2945
2946 - corrected 48(!) wrong entries in the Next Neighbor table of the
2947 Magic Camera (all in the inner part of the outer ring, mostly
2948 missing a single NN)
2949
2950 - Fixed a bug in the table describing the Next Neighbours of the
2951 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2952 have any neighbour)
2953
2954 - changed trigrate.C: now it calculates the pure NSB triggers from
2955 a camera file (generated with no showers), so there is no need
2956 to introduce them by hand in the BgR array (for more details
2957 please ask Abelardo)
2958
2959 - added MHHadronness (and MHadronness) as a general facility to evaluate
2960 the quality of a gamma-hadron seperation method
2961
2962 - changed MWriteAsciiFile to accept rules (MDataChain)
2963
2964 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2965 must be replaced by calles to MWriteAsciiFile::AddColumn and
2966 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2967 changed.
2968
2969 - Implemented generalized event-matrices (one row per event)
2970 (MHMatrix)
2971
2972 - implemented the one dimensional composite probabilities
2973 (MHCompProb, MCompProbCalc, comprob.C)
2974
2975 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2976 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2977
2978 - Added a camera display displaying the pixel numbers to the
2979 event display gui.
2980
2981 - Added Monte Carlo Informations to event display gui
2982
2983 - Changed the camera display to display the pixel numbering
2984
2985 - Added three buttons to the camera display to change the palette
2986
2987 - Added the number of used and core pixels after image cleaning
2988 to MHillas
2989
2990 - Changed the algorithm used in MHillas according to TDAS 02-03
2991
2992 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2993
2994 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2995
2996 - Added fCosDeltaAlpha to MHillasSrc
2997
2998 - The numbers of photons used to calculate fConc and fConc1 in
2999 MHillasExt are now scaled with the pixel size, so that one get
3000 a four times smaller value for the bigger pixels in the outer ring.
3001
3002 - added new task to smooth the camera contents (MCameraSmooth)
3003
3004 - added possibility to use interpolated pixel values for blind pixels
3005 instead of removing it completely from the analysis
3006
3007 - Implemented the possibility to save the whole eventloop with
3008 its setup to a file. This information can be read and from
3009 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3010 and MEvtLoop::MakeMacro. If you find something not working, please
3011 report - this stuff is still in a beta phase.
3012
3013 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3014 file having crab starfield, but also for all following files - fixed
3015
3016 - MTaskList::PrintStatistics can now be instructud to print also the
3017 title, too: use PrintStatistics(0, kTRUE)
3018
3019 - Changed the image cleaning so that pixels with to many 'used'
3020 neighbors are left used (to get rid of 'holes' in events)
3021
3022 - Introduced more output to the camera displays
3023
3024 - Added an array of histograms (eg one hist per run), MHArray
3025
3026 - Added a _preliminary_ version of the reader for CT1 PreProc files
3027 (MCT1ReadPreProc)
3028
3029 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3030 (thanks to Raquel)
3031
3032 - added the first energy estimator (MEnergyEstParam, estimate.C,
3033 estfit.C) using a parametrization
3034
3035 - Added some new Monte Carlo paremeter containers used to store
3036 setup information from the MC chain (MMcConfigRunHeader,
3037 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3038
3039
3040
3041 *** Version 0.7 (2002/04/30)
3042
3043 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3044 the pedestal mean value was saved incorrectly. For files from
3045 this versions we substract 0.5 from the pedestal mean.
3046 WARNING: This may effect your results, so don't wonder...
3047
3048 - First implementation of an algorithm using only triggered events
3049 for the collection area calculation
3050
3051 - Ascii Output can now also be used for parameter containers which
3052 doesn't overload MParCointainer::AsciiWrite
3053
3054 - The Ascii Output is now also capable of writing single data members
3055 of one container
3056
3057 - You are now able to change the order of the values written to the
3058 ascii file
3059
3060 - You can now specify a conversion factor for each data member written
3061 to an ascii file. This may be usefull to change the units of the
3062 data member (eg. degrees instead of millimeters in case of the
3063 hillas parameters)
3064
3065 - Replaced old MHillas by a new structure which allows you to extend
3066 the parameters stored in MHillas very easily:
3067 see MHillas and MHillasExt
3068
3069 - Added classes to handle source dependancy of image parameters:
3070 see MHillasSrc
3071
3072 - Added container (MBinning) to have a standard input for the binning
3073 in different histograms (eg. the Energy bins should be the same in
3074 all histograms)
3075
3076 - Changed Hillas histograms from mm to deg
3077
3078 - Added the flexible binning to the hillas histograms
3079
3080 - Added a filter for the alpha parameter (MFAlpha)
3081
3082 - It is now possible to write single data members of a class object to
3083 an output stream instead of the whole container only
3084
3085 - Added a generalized filter for a data member:
3086 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3087
3088 - Added a generalized Filter parser for more difficult filter rules
3089 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3090
3091 - Added new Monte Carlo histograms:
3092 MHMcEnergyImpact and MHMcEfficiency
3093
3094 - Added many new histograms needed for the flux calculation.
3095
3096 - Added a generalized histograms which can fill and show up to three
3097 data members in either a one-, two- or three-dimensional histogram, eg:
3098 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3099
3100 - Added:
3101 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3102 * calculation of <Theta> as a function of time (MHThetabarTime)
3103 they are needed in the flux calculation in
3104 order to select for a given bin in Theta (or time) the appropriate
3105 effective collection area, which is assumed to be given as a function
3106 of Theta and the true energy
3107
3108 - Added calculation of the migration matrix in the energy
3109 (MHMcEnergyMigration):
3110 the migration matrix describes the migration from the true (E_true)
3111 to the estimated energy (E_est); it is needed to determine the
3112 distribution of E_true from the measured distribution of E_est
3113 by unfolding
3114
3115 - changed the color palette in the camera display to DeapSea.
3116
3117
3118
3119 *** Version 0.6 (2002/01/15)
3120
3121 - Introduce the option of disable pixels (MBlindPixels and
3122 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3123 able to deal with Star Field NSB.
3124
3125 - Fixed a bug in the pedestals substraction
3126
3127 - Introduced verbosity levels
3128
3129 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3130
3131 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3132 work correctly (thanks to Abelardo)
3133
3134 - Introduced correct treatment of the diffuse Night Sky Background
3135 and NSB (MMcPedestalNSB)
3136
3137 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3138
3139 - Introduced MMcRunHeaders which contains monte carlo run informations
3140
3141 - Added a 'Print'-Task (MPrint) which calls the Print function
3142 of a parameter container for each event
3143
3144 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3145
3146 - changes to be more efficient with root 3.02/06
3147
3148 - root 3.02/06 fixes:
3149 + the memory leak when reading MRawEvtData
3150 + loosing more time than necessary to update the progress bar
3151
3152 - MWriteAsciiFile is now capable of writing more than one container
3153 in a line. For example: To be able to write Monte Carlo and
3154 Hillas values (energy and alpha) in one line.
3155
3156
3157
3158 *** Version 0.5 (2001/11/06)
3159
3160 - Added new GUI functionality (Analysis)
3161
3162 - Added a camera display to be able to display events in the camera
3163 together with the calculated hillas ellipse
3164
3165 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3166 object at any state of the analysis, so that the output are several
3167 states
3168
3169 - Fixed a bug in the collection area error calculation
3170 (Thanks to Ciro and Abelardo)
3171
3172 - Fixed a bug which causes merpp to crash in some environments
3173
3174 - Implemented auto enabling scheme for Branches to speed up reading
3175 a lot (see MReadTree and MTask)
3176
3177 - Fixed a bug in the Histogram classes which caused histograms to
3178 be written to a file by MWriteRootFile without request
3179
3180 - changed the object I/O from the old stylish root I/O to the new
3181 'auto evolution scheme' This was done only for classes which are not
3182 yet used in Monte Carlo files, so that these files are still readable.
3183
3184 - Added support for a progress bar in MEvtLoop and MReadTree
3185 (see the Analysis Window in Mars for an example)
3186
3187 - Fixed a bug in the package creation which disturbed the conversion
3188 between a mars version unpacked from a tar file and the repository.
3189
3190 - Changed the code to writer merpped (converted into root format)
3191 raw files, to get faster (around 10%)
3192
3193
3194
3195 *** Version 0.4 (2001/09/20)
3196
3197 - This release is made to compile on a root version >= 3.00
3198
3199 - Fixed a bug which causes MReadTree to read the first file only
3200
3201 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3202
3203 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3204
3205 - Added a task to write several container to a root file (MWriteRootFile)
3206
3207 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3208
3209 - Added calculation of the collection area (MMcCollectionAreaCalc)
3210
3211 - fixed some bugs in the Hillas calculation
3212
3213 - added filters to be able to control the task execution dependent on
3214 a parameter (for example: the number of level 1 triggers in a MC-file)
3215
3216
3217
3218 *** Version 0.3 (2001/04/23)
3219
3220 - Many demo macros added
3221
3222 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3223
3224 - Hillas Calculation added
3225
3226 - Standard image cleaning available
3227
3228 - MReadTree is now able to handle more than one file
3229 (Remark: of the same structure)
3230
3231 - Now we are able to display events in a first version of the
3232 Camera event display. To do this we must run the macro
3233 "macros/readCT1.C" to read data from CT1.
3234
3235
3236
3237 *** Version 0.2 (2001/01/24)
3238
3239 - First Implementation of a Gui to read the raw data. Start the
3240 gui with the command mars.
3241
3242
3243
3244 *** Version 0.1 (2000/12/20)
3245
3246 - First official release 0.1
3247
3248 - Changes:
3249
3250 + changed calling style of MRawPixelIterator from do...while to
3251 while-loop
Note: See TracBrowser for help on using the repository browser.