source: trunk/MagicSoft/Mars/NEWS@ 9413

Last change on this file since 9413 was 9413, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 132.3 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;showplot:
6
7 * If a file without a MStatusArray is opened all object (not just
8 canvases) found in the file are drawn. Note that this may result
9 in empty tabs.
10
11 ;callisto:
12
13 * Fixed a bug which prevented MAGIC Monte Carlo file from being
14 calibrated (ceres files worked)
15
16 ;ganymed:
17
18 * added new starguider calibration for sequences since 1000534
19
20
21
22== Version 2.3 (2009/03/07) ==
23
24 ;SUGGESTION
25
26 * There is no need to re-run any data because no change took place which
27 could have an effect on the output. However, if you want a
28 meaningful SrcPos plot for your MCs in sponde you must re-process
29 star for your MCs first.
30
31 ;REMARK
32
33 * File produced with this release containing a gamera geometry (which
34 are basically all files we produce per default) will not be readable
35 by older releases.
36
37 ;general
38
39 * fixed a few small bugs which could cause the display to crash in ganymed
40 and sponde
41
42 * in sequence file the date can now be omittet. In this case the
43 leading date with the underscore is missing in the expected filename
44
45 * the geometry class now also supports other geometries than just hexagons
46
47 ;automation
48
49 * added magnetic field Azimuth direction (ARRANG), currently
50 at ~ -7deg at La Palma
51
52 ;database
53
54 * plotdb.php: added default (sequences) for startup, added possibility
55 to set size of plot
56
57 * added a new table ''RunDataCheck'' which containes the rates after
58 image cleaning for every run which succeeded star. It can be
59 plotted using ''plotrundb.C''
60
61 ;merpp
62
63 * added support for Arehucas Version >= 200812140
64
65 * added support for Arehucas Version >= 200809030
66
67 ;mars
68
69 * The display now also displays the trigger pattern
70
71 * The display can now display ceres reflector (_R_) files
72
73 ;ceres
74
75 * added a uniformly distributed one-bin time jitter for the start of the
76 digitization. Otherwise the first photon would be digitized always with
77 the same alignment to the bins
78
79 * Added a plot showing the production height of the photons
80
81 * Moved the particle id from the event header to the run header
82
83 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
84
85 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
86
87 * Added many new options to control the tasks. For deatils see ''ceres.rc''
88
89 * Removed obsolete plots in pedestal and calibration mode
90
91 * Removed the non-NightSky photons from the plots where they are just
92 disturbing
93
94 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
95
96 * The daq event number now represents the readout number
97
98 * The camera ''electronics'' can now be ''switched off''
99
100 * A new tab ''Info'' now display basic things like the reflector
101 layout
102
103 * Improved reading speed for corsika files
104
105 * Improved memory handling (if a large ampount of memory was needed
106 for a single event all further events were stored in the same
107 memory and it was never freed, so the program took this memory
108 until the end)
109
110 * Converted the code from MMCS' reflector program to MSimAtmosphere
111 (instead of the tables build in for MAGIC Winter and Summer
112 atmosphere we use the values written by Corsika fitted to the
113 tabulated atmosphere given as input)
114
115 * For caluclating the displayed image parameters in ceres a basic
116 image cleaning removing isolated pixels is now done.
117
118 * The magnetic field direction (ARRANG) is now taken into account
119
120 * Added plot for the energy threshold after trigger ''Threshold''
121
122 * Added plot for the effective collection area after trigger ''TrigArea''
123
124 ;star
125
126 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
127
128 * The definition of fConcCore has slightly changed. The numbers
129 might decrease a little bit (the effect should be rather small)
130
131 ;ganymed
132
133 * added pointing model 328198
134
135 ;sponde
136
137 * The SrcPos plot for your MCs was so far meaningless because it just
138 displayes the MSrcPosCam data from the input star-files. Unfortunately,
139 this containes was never written to the star-files yet.
140
141 * A new Tab 'OnTime' is available which is an effective on-time
142 fit as in star but for all data. This is mainly for manual cross-check
143 of the effective on-time
144
145 * In some circumstances it might be necessary to re-calculate the
146 eff. on-time from the fit in the new tab, e.g. when a zenith distance
147 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
148
149 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
150 it to its own output file (for convinience)
151
152
153
154== Version 2.2 (2009/01/30) ==
155
156 ;SUGGESTION
157
158 * This release doesn't contain a major change which is expected to
159 change your results. Nevertheless there are small changes to
160 the calibration which can effect at least the first few hundred
161 events in any (mainly MUX and even more SUM) sequence a little bit.
162 So it is recommended although not necessary to reset your sequences
163 in the database before further processing.
164
165 ;NEW
166
167 * A first implementation of a Monte Carlo simulation program
168 (ceres - Camera Electronics and REflector Simulation) has been
169 implemented. It can simulate a full telescope already including
170 a complete reflector simulation and a flexible trigger and readout
171 simulation. Currently, no perfect setup is implemented and
172 especially the output of the program (data structure) should
173 be considered alpha state. Also the user interface is not yet
174 ready.
175
176 ;general
177
178 * All command line options after -- are now interpreted as
179 arguments (usually everything which doesn't start with a minus)
180 rather than options (usually everything which starts with a
181 minus). This allows to use file names starting with a -
182
183 * In all resource files you can now initialize the random number
184 generator. For details see: MJob::InitRandomNumberGenerator
185
186 * added a new program called ''readcorsika''. It's purpose is (in analogy
187 to readraw and readdaq) to read a Corsika output file (for now
188 only cherenkov output is supported) and print its contents in a
189 human readable form. It can also write the contents of this file
190 into a root-file.
191
192 * The calculation of the maximum distance to the origin in a MGeomCam
193 has been improved (edges might be further away than the sides).
194 This is just a tiny change but it might change the appearance of
195 the radial profiles a little bit.
196
197 * The default binning of the center-of-gravity plot has slightly been
198 increased
199
200 ;Database
201
202 * Added informations about the DC currents (fMinCurrents, fMedCurrents
203 and fMaxCurrents). The values are retrieved from the plots showing
204 the average DC currents of all pixels versus time.
205
206 * Websites with tables have now the opportunity to remove lines
207 ('-' button at beginning of each line) and get all lines back
208 ('+' at top of the column)
209
210 * Websites: added option to query only sequences containing sumtrigger
211 events
212
213 * Websites: added option to group by date (year, month, night) for runs
214 and sequences and enabled that combining of different group-bys,
215 e.g. status, date and source is possible
216
217 ;automatic analyis
218
219 * Rewritten producing plots in the web.
220 New plots, namely the output of plotoptical.C (extinction curve from
221 KVA), plotstat.C (status of the automatic analysis (percentage of
222 processed, analysed data etc.)) and plotusage.C (statistics of the
223 condor usage in the data center) has been are available now next to the
224 plots of plotdb.C
225 Mean values from the plots (output of the macro) are provided in a
226 txt file now.
227 The creation of the plots for callisto, star and ganymed in the web is
228 now steered via database. Consequently the plots are faster and
229 reliable up-to-date.
230 For all plots, a new layout is available facilitating the browsing
231 through the plots and providing additional information on the
232 displayed values. (tabs.php) These plots are linked from the DB
233 websites and the wiki.
234
235 ;statusdisplay
236
237 * The ''Loop'' entry in the menu bar now contains an option to pause
238 the loop and to process single events.
239
240 ;merpp
241
242 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
243 instead of RunHeaders)
244
245 * Now allows to merpp files newer than 2008/09/03.
246
247 * Added fixes for wrong (wrong or double) run- and file-numbers
248 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
249
250 ;callisto
251
252 * Extracting the pulse position for the pulse position check events
253 with sum trigger were denied. This decreased the statistics
254 extremely and therefor the resulting puse position was calculated
255 quite weak. Now sum events pass the calculation if and only if they
256 have also a level 1 trigger.
257
258 * the extraction of pedestal events and pulse position from the
259 first data events is now more automatic and makes sure that
260 a more precise number of events is extracted independent of
261 the ratio with which pedestal events or events with signals
262 are contained in the data.
263
264 * Updated Muon calibration constants for all MUX data (teh changes were
265 all smaller than 5%)
266
267 ;star
268
269 * For the calculation of the effective on time all sum-triggered events
270 were skipped. Now all Level1-triggeres events will pass. This might
271 result in a slight inaccuracy of the effective on time.
272
273 ;ganymed
274
275 * If the source position is more than 1deg away from the camera
276 center an error is raised now.
277
278 * Hopefully fixed the bug ''ganymed crashes when resized''
279
280 ;sponde
281
282 * Fixed a problem which causes the fitted spectral slope to be displayed
283 incorrectly. If you use MJSpectrum::FormFlux in your macros make
284 sure that the parameter 0 of your fit is negative.
285
286 * Added a histogram showing the read source position of your MCs
287
288
289
290== Version 2.1.1 (2008/08/04) ==
291
292 ;Database
293
294 * Added the median number of photo electrons from the calibration
295 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
296 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
297
298 * Added fTotOnTime, which is the on-time as given by the run-headers
299 (in contradiction to fAbsOnTime which comes from CC)
300
301 * Added new primaries for the new data structure (Magic II): for the
302 tables dealing with sequences (SequenceBuild Status, Sequences,
303 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
304 this is the telescope number (fTelescopeNumber) for the tables dealing
305 with runs (RunData and RunProcessStatus) this is in addition the file
306 number (fFileNumber)
307
308 * Added column fPriority to the status tables to be able to steer the order
309 in which the data is processed. As default the run, sequence and dataset
310 number are used.
311
312 ;automatic analyis
313
314 * Adapted scripts to the new data structure: They can handle now different
315 telescopes (getting the information as usual from the database).
316 The paths for Magic 2 are not yet implemented.
317
318 ;general
319
320 * should work now with root 5.20/00 (please note that root 5.20/00
321 we encounter crahses in the status display which are ot yet
322 understood)
323
324 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
325 instead of the base name of the file. This makes them easier to
326 access from the code
327
328 * Default Monte Carlo names in MSequence do not require the _E at
329 the end anymore
330
331 * where abrrevating a sequence file with a sequence number is possible
332 also "telescope:sequence" is now accepted, e.g.:
333 star 2:2000123 --out=output
334 see the programs' help for more details.
335
336 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
337 from the database. See the constructors for more details.
338
339 * MReadTree now supports friends
340
341 * MReadTree can now read also files not written by MARS and store
342 the data encapsulated in emulated MParContainers
343
344 * added a new starguider calibration valid since 15.1.08
345
346 ;showplot
347
348 * showplot can now read more than one file at once. This is especially
349 inetersting if reading files containing pure canvases
350
351 ;merpp
352
353 * we merpp the dc currents now also from the camera reports (they have
354 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
355
356 * In the automatic analysis we omit merpping of the currents from the
357 caco files and use the lower rate camera reports from the cc files
358 instead
359
360 * merpp has been redisigned to allow merpping of the cc-reports
361 of a whole sequence. This allows to design a very simple analysis:
362 mkdir output
363 ./callisto 100776 --out=output
364 ./merpp 100776 output
365 ./star 100776 --ind=output --out=output
366 Instead of the sequence number also sequence files are accepted.
367
368 * Implemented a fix for run-numbers between 1001348 and 1001396
369 which were incorrectly assigned by the cc.
370
371
372 ;callisto
373
374 * added a filter again which was was removed in the last release.
375 it removed the most brightest events. This should not change
376 any analysis result because these events are so bright that
377 they cannot be analysed anyway, but the bad-pixel plots doesn't
378 show outliers.
379
380 * updated muon calibration constants for the periods 51-57,
381 58-63 and 67-
382
383 ;star
384
385 * The camera currents are now displayed with the rate of the camera
386 reports instead of the caco reports
387
388 ;ganymed
389
390 * if mc camera files are new enough (>=8) the source position in the
391 camera is now calculated from the stored telscope and shower
392 orientation (Note, that this might not be suitable in all cases
393 depending on the aim of the study. These case still needs
394 implementation)
395
396
397
398== Version 2.1 (2008/06/18) ==
399
400 ;Database
401
402 * introduced average temperature and wind speed from star-files
403
404 * introduced average values from Pyrometer (mainly Cloudiness)
405
406 * introduced the ratio of accepted calibration events in the
407 calibration run
408
409 * introduced the average rates of the different trigger pattern,
410 e.g. the rate of pedestal and calibration events, from the signal-file
411
412 ;general
413
414 * fixed GroupBy options in plot*.C macros
415
416 * only display KVA points (not the Tuorla points) in plotoptical.C
417
418 * all programs now allow to add resources to the ones from the resource
419 file or overwrite them from the command line. This can be done like this
420 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
421 if something seems to be wrong you can debug what the program is doing
422 using the option --debug-env=3
423
424 * increased the diversity of debug levels. That also means that with -v3
425 you get now less output, i.e. only the output which is important for
426 an analysis. To get more output which helps for debugging try 4, 5 and 6.
427
428 * fixed a problem in the task synchronizing the reading of the reports
429 and the data stream. The effect was that in some circumstances the last
430 events of some trees could have been skipped. Since this is only a
431 very tiny part of the data no severe effect to your analysis results
432 is expected (an exception might be very short, i.e. singel runs,
433 datasets).
434
435 * Dataset file now allow to include the sequence file directly within
436 the dataset file and also allow to exclude single runs from the dataset.
437 (for more details see Class reference of MDataSet)
438
439 * Sequence files now allow for excluding runs from the analysis
440 (for more details see Class reference of MSequence)
441
442 * added code to process the sum-trigger flag
443
444 * the histogram classes MH3 and MHn now support profile histograms
445
446 * the histogram classes MH3 and MHn now support labels at the axis
447
448 * the Random Forest Train-classes (MJTRain*) now store the used datasets
449 in the output file
450
451 * the MFMagicCuts have a new option to allow a linear area cut (for
452 special studies)
453
454 * The liniking of the shared object is now done into a file defined
455 by 'mktemp'. This should be a local file system which accelerates
456 liniking a lot.
457
458 * The code has been prepared for compilation with root 5.18/00d
459
460 * The MHEnergyEst histogram now shows the distribution of
461 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
462 and (Eest-Emc)/Emc vs Emc.
463
464 * fixed mars (event display) for merpped raw-data and MC data
465
466 * adapted the synatx of sequence files to allow for the new run/file
467 scheme. For more details see class description of MSequence
468
469 ;showplot
470
471 * Added support for tiff files
472
473 * Added support for csv files (tables containing tab number,
474 name and title)
475
476 * Tabs now can have a title which is displayed in the postscript file
477
478 * When multiple file are written at once (e.g. pngs from a display)
479 it is now possible to use the tab name and or tab number in the
480 file name. For details see showplos's help.
481
482 ;merpp
483
484 * Implemented cc file version 2008-02-20/0
485
486 * Implemented cc file version 2008-05-19/0
487
488 * With new options merpping can be restricted (in addition to the
489 run-number) also by telescope and file number.
490 For details see "merpp --help"
491
492 * Implemented raw data format 11 (the most important change, except
493 from plenty of changes in the format definition, is the addition
494 of the file-number in the header) If nobody makes a mistake this
495 format should have the advantage that it is by definition forward
496 compatible, so old programs will be able to read newer formats.
497
498 * Added Pyrometer information to default output (stored in a new Tree
499 Pyrometer, needs a complete new merpp, i.e. new calibration)
500
501 * Merpping (also update) can now be restricted to one single report.
502 For example:
503 If you want to update an old file with Pyrometer information call
504 merpp --only=Pyrometer --update
505
506 ;callisto
507
508 * in the pedestal processing now at least 50 processed events are
509 required for succeeding.
510
511 * the signal and calib files now contain also the sequence information
512
513 * the two MPedestalCam in the calib file now have proper names
514 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
515
516 * Both pedestal cams now contain the number of events processed
517
518 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
519 i.e. for the extraction of the calibration pulses basically the average
520 over all events of the first slice instead of all slices was used.
521 Since pedestal and calibration constants are continously recalculated
522 this only effected the very first events of every sequence.
523
524 * For the extraction of the position of the maximum sample now the
525 extraction range is set automatically to the extraction window,
526 before the whole accessible range was used.
527
528 * If the number of samples in the events and the number of samples
529 in the run-header disagrees now an error is raised (this can
530 happen in not well simulated Monte Carlo files)
531
532 * In the case of MUX-data pedestal events with the lvl1 trigger flag
533 could survive into the pedestal calculation -- fixed.
534
535 * Tab "TrigPat" added showing the distribution of the trigger pattern
536 as found in the run-files (normalized with the run length)
537
538 * The selection of events from the trigger pattern has been improved.
539 If the trigger pattern is corrupted events won't pass anymore.
540
541 * Added a new command line option --dev-null to suppress output of
542 Y-files (this is useful for test cases)
543
544 * added a new tab "CalPos" showing the arrival time of extracted
545 interleaved calibration events
546
547 ;star
548
549 * the star file now contains also the sequence information
550
551 * Added a new command line option --dev-null to suppress output of
552 I-files (this is useful for test cases)
553
554 * Tab "Rate" added showing the distribution of the trigger pattern
555 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
556 the Y-files (normalized with the run length)
557
558 * The effective on-time calculation doesn't use events with only
559 sum-trigger anymore
560
561 * The data in the MHWeather tab has been reorganized. The never
562 working solar radiation has been removed and the data from
563 the pyrometer (cloudiness, air and sky temperature) is
564 displayed in addition.
565
566 ;ganymed/sponde
567
568 * Now data points are even shown correctly if they have error bars larger
569 than one sigma. Points with null or negative significances are omitted.
570
571 * DrawNicePlot now allows to set a projection range
572
573 * Updates pointing models. One is applied after the implementation
574 of the new LUTS in August, the other one is applied after the
575 next major change of the pointing model in October. Note that
576 these models are preliminary and give wrong results below Zd=65deg
577
578 ;sponde
579
580 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
581
582 * a new option "--force-runtime" is available. In case of very short
583 datasets (for light-curves) which are in the order of a few
584 minutes the calculated effective on-time is not very acurate because
585 it is quantizised in the order of a minute. Therefore you can switch
586 to using the real run-time instead (remakrt: this ignores any
587 dead-time!)
588
589 * a more analytical way is used to "fill" Monte Carlos into regions
590 of impact parameters which have not been simulated because the
591 trigger efficiency is assumed to be 0.
592
593 * estimated sensitivity curves for hi and lo zenith angles are shown
594 scaled to the correct observation time and collection area
595
596 * the Monte Carlo events after cuts are now written to the output file
597 if an output file given
598
599
600
601 *** Version 2.0 (2007/09/03)
602
603 - database: the position used for the pulse pos check was missing
604 in the callisto output and could thus not be filled into the DB.
605 Also the old values seemed not exactly the PulsePos used for
606 teh check.
607
608 - general: Resource file now allow an Include-Resource, i.e. you can
609 read a resource file with default settings, include it in your
610 resource file and overwrite the settings in your file. More than
611 one include file is allowed. Inclusions can be iterative.
612 Include: mydefaults.rc yourdefaults.rc
613 The resources in the first file have higher priority than the
614 second file.
615
616 - general: Now the output files (calib*.root, etc) also contain the
617 resource file (to check it open it in the TBrowser and choose Print()
618 from the context menu)
619
620 - general: Dataset files now allow to overwrite the default path
621 to search for sequence and data files. Note, that the program
622 option and individual resources will overwrite it. For example:
623 SequencePath: /magic/montecarlo/sequences
624 DataPath: /magic/montecarlo/star
625
626 - general: Fixed a problem with variables in MDataPhrase. It seems
627 that only optimdisp (didn't work) was effected.
628
629 - general: Some improvements to the optim and train processing. For
630 example the ststud window now got a proper title.
631
632 - general: The "Status Display: " was removed from the window title
633 within an Eventloop.
634
635 - general: added a new flexible histogram-class (MHn) which can be used
636 for example in testing after optimizations or training to produce
637 user defined histograms.
638
639 - general: The Random Forest now allows attaching an evaluation
640 function which is applied to its output. This allows to train
641 on whatever you like (eg. train on log10(energy), but return
642 energy)
643
644 - general: The Random Forest training of energy (trainenergy.c) and
645 disp (traindisp.C) has been improved by more graphical output to
646 judge the result.
647
648 - general: The training of energy (trainenergy.C) has been improved
649 a lot by training on a different quantity than energy. It gives
650 a result which is highly independant of the source spectrum
651 and shows lower bias than all other options.
652
653 - general: Dataset files are allowed to contain collections of
654 datasets. For more details see the class reference of MDataSet.
655
656 - general: The default WobbleMode in a datset file now (if not
657 overwritten) is "auto", i.e. wobble mode is set if the dataset
658 doesn't contain off-sequences.
659
660 - merpp: Merpp can read file format version 9 now. Please realize
661 that for file format version 9 the extraction range is different
662 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
663 the first and last 15 slices have been removed from all MUX data.
664
665 - mars: Similar to writing movies you can now select events which
666 should be displayed in your display. Therefore add the following
667 lines to your mars.rc:
668 MFEvtNumber.FileName: ganymed00223552.root
669 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
670 The input file can be a ganymed-file after (ganymed*.root) or
671 before (ganymed*-summary.root) file. For example to select all events
672 from your on sample after cuts (excluding the ThetaSq cut) use
673 MFEvtNumber.Selector: DataType.fVal>0.5
674 To show all events from your on-sample after quality cuts
675 use the summary file instead.
676
677 - mars: new ways to call mars are implemented. Instead
678 of calling
679 mars filename.root
680 you can now also use
681 mars sequence.txt
682 or
683 mars sequence.txt inputpath
684 or replace sequence.txt by the sequence number if the default
685 sequence file should be used.
686
687 - mars: The default size has been increased
688
689 - mars: There are two new heckboxes which allow to switch off
690 the calculated image parameters
691
692 - callisto: was broken for MCs... fixed.
693
694 - callisto: improved calculation of spline coefficients a lot. This
695 leads to a further improvement of the event rate calibrating MUX
696 data of about 15% (175evt/s instead of 150evt/s)
697
698 - callisto: finally the raw data we read is now real 16bit (with
699 10bit precision) for MUX data and not a stripped 8bit number
700 anymore. Due to scaling of the numbers (without precision loss
701 into an [0-256[ range, the final numbers for pedestal, pedestalrms
702 and extacted signal don't change. However, at all places where
703 raw data is directly accessed (eg. saturation and variation
704 limits in the signal- and pedestal-extraction) the numbers
705 refer still to the data's 16bit range.
706
707 - callisto: The maximum arrival time difference used in the bad
708 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
709 for both, old FADC and MUX-FADC, data.
710
711 - callisto: Be aware that callisto is now calibrating the arrival time
712 in nanoseconds rather than time slices. Also all following tasks
713 have been changed to assume ns units now. If you star data
714 calibrated with an older version it might be necessary to adapt
715 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
716 to obtain optimal results. The plot in the PulsePos tab
717 will now be in ns, too. This might also mean that the Muon
718 analysis in star might not work as perfect as expected as long
719 as old files read in.
720
721 - callisto: The calibration constants of earlier updates got lost
722 somehow. All constants have been updated.
723
724 - star: The PSF is now determined from the profile of the ArcWidth
725 instead of arcwidth/radius. The old way gave to much weight
726 to the bins with low statistics. The reference lines have been
727 updated.
728
729 - star: For speed reasons events suitable for the muon analysis
730 are now also preselected by fConcCOG<0.1 which seems to be a very
731 good preselector for muons.
732
733 - star: is now calculating a new timing parameter the Slope along
734 the major and minor axis of the shower. Therefore a numerical
735 solution of a line-fit is used. To use MHillasExt.fSlopeLong
736 and MHillasExt.fSlopeTrans don't forget to multiply it with
737 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
738
739 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
740 have been removed from MNewImagePar. They have never been good for
741 anything.
742
743 - star: Implemented a new recursive algorithm which is supposed to be
744 faster. Also implemented new cleaning oiptions, which are:
745 + CleanLevel0:
746 The cleaning level above single core pixels can be kept
747 + KeepIsolatedPixels:
748 Define whether single core pixels should be kept
749 + TimeLevel1:
750 The coincidence window in nanoseconds to single used neighbors
751 + TimeLevel2:
752 The coincidence window in nanoseconds to two used neighbors
753 + PostCleanType:
754 MOde in which a time dependent post cleaning should be applied
755 0: No post cleaning
756 1: Require for each used pixels at least one used neighbor
757 within a time-window of CleanLevel1
758 2: Require for each used pixels at least two used neighbor
759 within a time-window of CleanLevel2
760 3: Require first two and second one used neighbor
761 within a time-window of CleanLevel1 and fCleanLevel2
762 respectively
763 + RecoverIsolatedPixels:
764 - recoveres isolated core pixels if they have a used neighbor
765
766 - mars/star: The new default cleaning is:
767 + CleanLevel1: 6.0
768 + CleanLevel2: 3.0
769 + CleanTime1: 1.75
770 + CleanTime2: 1.75
771 + PostCleanType: 3
772
773 - star/ganymed: The old spark-cuts have been replaced by new ones.
774 These new spark cuts have been cross checked with the sequences
775 84720 (before splitter), 101041 (after splitter) and 223539 (new
776 FADCs). In all cases they seperate pretty well, but of course not
777 perfect. Monte Carlos have suggested to tighten the cuts a little
778 bit further at low sizes. This has been done.
779
780 - ganymed: IMPORTANT - The spark cuts have been changed to match
781 all available data more or less well. This might mean that for
782 YOUR data there are still sparks visible.
783 Whenever you do an analysis you have to make sure that NO sparks
784 survive your cuts!
785
786 - ganymed: The old hadronness and size cuts have gotten new indices
787 (10, 11). The old indices 8 and 9 now mean an additional condition
788 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
789 If you want to switch off this cut just move the line far away enough,
790 e.g. by setting c[9] to -500. Please update your ganymed.rc files
791 accordingly!
792 The unit of c[9] is deg. It is the dist at which your cut will
793 cross the slope==0. The unit of the slope is ns/deg. So if
794 you readin files calibrated with an older Mars-version you
795 have to adapt the default value for c[9] to the FADCs:
796 - Multiply by two for the MUX FADCs (run number > 200.000)
797 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
798 - Multiply by 42 for the meaning of life (run number = 200.000)
799
800 - ganymed: The old Cut0 is now called CutQ and is calculated before
801 the source position is caluclated. If you need a quality cut
802 including source dependant data (be very carefull with this!)
803 you have to use Cut0 instead.
804
805 - ganymed: now properly supports three off regions in wobble mode.
806 It will be the default from now on in ganymed_wobble.rc. To change
807 the number of off-regions use
808 NumOffSourcePositions: 1
809 in your ganymed.rc. Also by default no off-theta cut will be done
810 anymore so that you will get a background level higher than the
811 signal level in your ThetaSq plot for ThetaSq>0.2.
812 Due to this be carefull changing the scaling mode away from
813 "None". You will underestimate your signal if your scale interval
814 is not properly set.
815 (Rem: ThetaSqN is no longer needed)
816
817 - ganymed: is now storing the events of all (on- and off-)
818 source positions even in the case of more than one off-source
819 position. This should allow sponde to work properly and the
820 energy estimation is done correctly in all cases (without any
821 "nearest position" trick)
822
823 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
824 with a real pointing model for the starguider is done, calibrated
825 with more than thousand tpoints taken from this date on.
826
827 - ganymed: was broken for Wobble-MCs... fixed.
828
829 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
830 has changed. Note that your old ganymed.rc will be incompatible
831 with the new algorithms! Please check the ganymed.rc files and
832 the class description of MFMagicCuts for more information.
833 It is recommended at the moment to use identical Disp-Parametrizations
834 for on/off- and wobble-mode. If cuts are optimized only
835 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
836 should be optimized. All other values should be kept as they are.
837 If you want to do an anylsis without timing a parameters, you can
838 switch off the timing cuts by seeting parameter 7 to a very small
839 value (eg. -99). To remove the slope parameter from the disp
840 paremtrization set parameter 8 to 0.
841
842 - ganymed: The distribution of observation time versus zenith
843 angle is now shown for off- AND on-data.
844
845 - ganymed: The contents of the source position plot are no longer
846 averaged, thus a lot of (fake) events between the two wobble
847 positions have disappeared.
848
849 - ganymed: There is a new tab "CutT" it contains the VsSize plots
850 with the CutT, whihc is defined in ganymed.rc, applied. It
851 is resonable to use your theta-cut for it, to see if there is
852 something strange (sparks!) in your signal-region.
853
854 - ganymed: To choose a dataset from a collection in a dataset file
855 use the new command line option "--dataset=12345"
856
857 - optim, sponde: should now properly support three off-regions.
858 Just produce your ganymed summary files with three off-regions.
859 optim and sponde will automatically get all off events from
860 all off-regions from this file. Please do not forget to
861 set the scaling in optimwobble.C properly:
862 fit.SetScaleUser(1./3);
863 it is not yet read in automatically (will follow soon).
864 In the case of fixed Scale you can also use
865 cuts.SetThetaCut(MFMagicCuts::kOn);
866 no off-cut needed.
867 Be carefull in case of three off-regions when switching on
868 scale mode. Make sure that the scale interval is set correctly.
869
870 - sponde: sponde.rc and sponde_onoff.rc are now idetical
871
872 - sponde: the resouce files have been rewritten with a lot of
873 comments and a well working parametrization for an energy estimator
874
875 - sponde: In the estimated energy versus monte carlo energy plot the
876 contents where exchanged.... fixed.
877
878 - sponde: the so called "accurate"-mode has been removed. It didn't
879 give any improvement in accuracy, only decreased execution speed.
880
881 - sponde: the so called "simple"-mode has been removed. It didn't
882 give any improvement in simple.
883
884 - sponde: the so called "refill"-mode has been removed. It was anyhow
885 not implemented.
886
887 - sponde: now checks whether the theta distribution of your on-data
888 and the theta-distribution of your Monte Carlo sample (after
889 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
890 sample is incomplete) execution is stopped. Execution can be forced
891 using the new option --force-theta. Use this option with care!
892
893 - sponde: Proper collection areas can now be constructed also from
894 Monte Carlo samples generated with different maximum impact
895 parameters. Note that in previous version you neither got
896 a warning or failure, nor was there any obvious sign that the
897 collection area was overestimated due to usage of files with
898 different maximum impact parameters.
899
900 - sponde: If MC files with different lower energy limits are used
901 the primary MC spectrum is artificially completed down to the
902 lowest energy used at all. WARNING: that this gives correct
903 collection areas ONLY if none of the events in this region would
904 survive your cuts at all.
905
906 - sponde: the output file now contains more information about
907 the spectrum (eg. the full 2D collection area histogram).
908 Note, that this information can only be written to the file
909 if it is stored automatically via command line argument.
910 If you only store the status display from within the display
911 the information is lost.
912
913 - sponde: added a new tab "Disp". It shows the residual of the disp
914 (Disp-Dist) versus several parameters and it is meant to judge the
915 quality of the disp estimator. In the ideal case the residual is zero
916 and doesn't depend on any variable. The tab is displayed after
917 CutQ and Cut0.
918
919 - sponde: added a new tab "Energy". It shows the residual of the
920 energy (lg(estimated energy)-lg(monte carlo energy)) versus
921 several parameters and it is meant to judge the quality of the
922 energy estimator. In the ideal case the residual is zero
923 and doesn't depend on any variable. In reality even a good estimator
924 can show residuals versus Monte Carlo energy. The tab is displayed
925 after all cuts.
926
927 - sponde: added a new tab "EventDist" showing the unweighted real
928 absolute number of events of your sample after cuts. This tells
929 you how many events with this energy you had in your MC files.
930 The same information you get from the error bars of the weighted
931 histograms, but this is less intuitive.
932
933 - sponde: The spectrum plots now show the crab- and 1553-spectrum
934 for comparison. It is not meant to show these curves in
935 publications, they are only for production.
936
937 - sponde: The OriginalMC tree with the events produced by corsika
938 is now processed only once
939
940 - sponde: Finally fixed most annoying bug, which has effected the
941 last bin of the collection area. It was the problem that binnings
942 of root histograms are from 1 to n (included) but there was a C-like
943 loop in sponde from 0 to n (excluded). Now the loop also includes
944 correctly under- and overflow-bins. The worse thing with this is,
945 that for the events in the highest bin not only the bin-content
946 was wrong, but also the weights applied to these events, which could
947 in pricipal effect also other parts of the distribution (eg. due
948 to energy estimation). Fortunately it effected only a few events
949 in most cases.
950
951
952
953 *** Version 1.2 (2007/05/14)
954
955 - database: The database now has two new values Unsuitable50 and
956 Unsuitable01. They express the number of pixels which are
957 unsuitable for more than 50%, respectively more than 1%, of
958 all calibrated event. It is a more accurate number than the
959 previously used numbers, because they only take the first
960 calibration (ignoring the interleaved calibrations) into account.
961
962 - database: The database now has two other new values UnsuitableMax and
963 DeadMax. They express the maximum number of pixels which were
964 unsuitable, respectively dead, during the sequence. Because
965 of high pedestal rms (cars passing) a few events with very high
966 numbers of unsuitable pixels can happen. Not to suffer from this
967 effect we don't take the highest 0.1% of the numbers into account.
968
969 - general: fixed a bug which caused callisto and star to stop working
970 properly because the callisto output was currupted
971
972 - general: a script called scripts/makemovie has been added which
973 simplified the process of producing several movies from a single
974 sequence with different setup.
975
976 - callisto: Some more code cleanup. Started to remove old obsolete
977 code from cvs.
978
979 - callisto: The extraction of the pedestal with the extractor was
980 not random. It seems that extracting at one position is still biased
981 (for example in the first or last slices we could still suffer from
982 switching noise) Now it is completely random.
983
984 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
985 pedestal files) individual pixels could be skipped due to high
986 variations. This was already the case for the pedestal extraction
987 from the lo-gains since the beginning and properly handled
988 there, but was introduced in the extraction from the pedestal files
989 a while ago. To calculate the average value it was still divided
990 by the number of events procesed not by the number of summands
991 really summed. This let to a pedestal which was a tiny amount too
992 small (for a few piels in the order of 0.1%). This led to an slightly
993 positive offset of the randomly extracted pedestal for a few pixels.
994 I doubt that this has a big effect on the result, because the effect
995 on the individual numbers is quite small. Due to this it is suggested
996 that you rerun your calibration to make sure you are without any
997 avoidable bias.
998
999 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1000 the median rms of the absolute arrival time and expressed in significance
1001 levels. This replaces the old meaning of an abolute upper limit. An
1002 absolute upper limit doesn't make much sense, because in our data
1003 all arrival times are shifted at the same time (in fact it might be
1004 a shift of the artificial trigger w.r.t. to the light flash).
1005
1006 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1007 of the number of unsuitable pixels over the whole sequence. This
1008 is usefull mainly to judge if an intermediate calibration had
1009 problems.
1010
1011 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1012 of the number of dead pixels over the whole sequence. Dead pixels
1013 in this context are unmapped pixels, i.e. pixels which could not
1014 be interpolated, and thus are ignored in the further analysis.
1015
1016 - callisto: It is now possible to use the position of the maximum
1017 of the spline as arrival time instead of the leading edge even
1018 when using the integral for the signal. Therefor set the extraction
1019 type to kIntegralRel ("IntegralRelative") and the relative height
1020 ("HeightTm") to -1:
1021 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1022 MJPedestalC1.ExtractSignal.HeightTm: -1
1023
1024
1025
1026
1027 *** Version 1.1 (2007/04/27)
1028
1029 - general: The new class MGeomCamDwarf contains the camera geometry
1030 for our prefered Dwarf camera and can be used to create general
1031 geometries of roundish or hexagonal cameras.
1032
1033 - mars: The default cleaning is now abolute 8.5/4.0.
1034
1035 - mars: The resource file mars.rc now contains examples for MUX data
1036
1037 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1038 data containing only 10-bit information is still cooked down to
1039 8-bit, by cutting away the lowest 8-bit.
1040
1041 - merpp: When reading raw data the data is now stored in a single
1042 array. The lo-gain array is obsolete. The interface stays the same.
1043
1044 - callisto: To process the new MUX data use the resource file
1045 callisto_mux.rc
1046
1047 - callisto: The -root and -raw options to read merpped raw data have
1048 been removed
1049
1050 - callisto: If the -mc option is given the sequence-name can now be
1051 replaced by the MC sequence number
1052
1053 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1054 -mc option can now be omitted
1055
1056 - callisto: Started further simplification by removing obsolete
1057 dependancies on MCalibIntensity*Cams.
1058
1059 - callisto: removed unsused intensity calibration from MJCalibration
1060 for further simplification
1061
1062 - callisto: for simplification removed references to
1063 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1064 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1065 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1066 (this should at minimum change nothing at all, and at maximum
1067 improve thing if these containers where somewhere not handled
1068 properly)
1069
1070 - callisto: Added the option to write an event movie. Please use
1071 this option with care (huge files) but exessively to understand
1072 our events. For further documentation please refer to the
1073 IACT wiki
1074 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1075
1076 - callisto: Improved binning for the pulse position check histogram
1077
1078 - callisto: The code calculating the pulse position checknow takes
1079 the pedestal into account
1080
1081 - callisto: The arrival time is now stored with full precision this
1082 helps to get rid of artefacts in histograms. For the signal this
1083 is not necessray because it is displayed in log-scale anyhow
1084
1085 - callisto: Fixed a problem with internal exclusions. Pixels which
1086 have once been marked as unsuitable didn't get the necessary
1087 histograms filled anymore to be rechecked with each interleaved
1088 calibration.
1089
1090 - callisto: The relative arrival time resolution (the rms of the
1091 relative arrival time offset) is now checked against its
1092 median and the median deviation, instead of the average
1093 plus an absolute offset.
1094
1095 - callisto: The relative arrival time offset is now calculated
1096 w.r.t. its median not w.r.t. to an artificial reference pixel.
1097
1098 - callisto: The relative time calibration now marks pixels with
1099 outlaying offset as unsuitable
1100
1101 - callisto: The interleaved relative time calibration has been switched
1102 on. The advantage is that pixels which are marked as outliers
1103 now can recover. An improvement over time is not expected, because
1104 the relative time calibration seems stable.
1105
1106 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1107 option can now be omitted.
1108
1109 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1110 or the option "-mc" is specified as default the monte carlo datacenter
1111 paths (/magic/montecarlo/...) are used if not overwritten in the
1112 dataset file.
1113
1114 - ganymed: The output files now contain run- and event-number for all
1115 events, accessible as RunNumber.fVal and EvtNumber.fVal
1116
1117 - ganymed: Added a plot showing the source position in the camera also
1118 for wobble mode
1119
1120 - ganymed: In addition to the existing task which can be setup to
1121 be executed after Cut1 a final task called "EstimateEnergy"
1122 has been added, executed before writing the final output
1123 (ganymed00000000.root). The task setup in all three cases
1124 can be choosen individually. (For all three(!) cases you
1125 can for example choose MRanForestCalc. For examples see all
1126 sponde*.rc and all ganymed*rc)
1127
1128 - ganymed: If a container "MEstimatedEnergy" is found in the
1129 parameter list (eg. because it was setup by MEstimateEnergy)
1130 it will be written to the output file.
1131
1132
1133
1134 *** Version 1.0 (2007/02/16)
1135
1136 - database: Website to plot values from the database has been added.
1137
1138 - database: The rate of spark events as found by star is now kept
1139 and the rate after cleaning is now with spark events subtracted
1140
1141 - general: The changes to the interpretation of phrases lead to
1142 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1143
1144 - general: Added example files how you can create your own calendar
1145 (eg. as christmas present) with Mars. Just run
1146 root macros/tutorials/calendar.C
1147
1148 - general: Added a possibility to display grouped data in the plotdb.C
1149 macro (and similar macros). This allows to plot hourly, nightly,
1150 weekly, monthly and yearly averages.
1151 For more details see the plotall function of the macro
1152
1153 - general: fixed the error display of the camera display. It showed
1154 wrong results.
1155
1156 - general: fixed a memory leak when reading many MStatusDisplays
1157
1158 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1159 between a spherical and a parabolic mirror
1160
1161 - callisto: We have a new pulse position check which takes the properties
1162 of the extractor automatically into account. So no need to set
1163 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1164 left is done. If possible the lo-gain extraction start and hi-gain
1165 extraction end is changed accordingly. If no proper extraction range
1166 can be set (hi-gain too much to the left) an error is raised.
1167
1168 - callisto: New swapped pixels have been found and corrected
1169
1170 - callisto: Redone the signal extraction this includes:
1171 + Unified the algorithms to extract the pedestal for all pedestal
1172 extractions done
1173 + Unification of hi- and lo-gain into one array
1174 + Unification of hi- and lo-gain extraction for Spline and
1175 Digital Filter (means now exactly the same algorithm is used,
1176 not a copy-and-pasted one)
1177 + Store pedestal subtracted data in a common place
1178 + Improved extraction algorithms. If the algorithms search a
1179 maximum but don't find one they don't return the maximum anymore
1180 + Improved the extraction such that a information for signal
1181 and time which is consistent is returned
1182 + replaced the numerical spline with a (not slower) analytical
1183 solution
1184 + Lowered the saturation limit from 250 to 245 to make sure that
1185 we are far away in all pixels from problems with the clock-noise
1186 + The start of the lo-gain extraction is calculated from the hi-gain
1187 arrival time. In case of saturation an estimation is used.
1188 + the hi-gain window was extended to slice 16. This allows extraction
1189 of very late pulses in single pixels or of huge hadron showers.
1190 + Now uses the lo-gain extraction range for pedestal extraction,
1191 not the hi-gain range in the lo-gain
1192
1193 - callisto: New hi-/lo-gain calibration constants have been produced
1194 for all periods from the statistic of the whole period. They are
1195 now used automatically depending on the periods. The old constants
1196 where deviation in avarega about 2%-3%. The constants are very
1197 stable from period to period (<<1%) except for exchanged channels.
1198 In a few cases the constants used so far were off by 1%-2% (maybe
1199 temperature effects?)
1200
1201 - callisto: To gain obsolete space we do not write the
1202 MPedestalFundamental anymore. Also calibration and bad pixel
1203 treatment is not done for it anymore because it has never been used.
1204
1205 - callisto: Fixed a bug in the seuqence handling which caused the
1206 light condition to be ignored
1207
1208 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1209 basically the same as "Cleaned" but the distribution devided into
1210 the events fullfilling a spark cut or being rejected by it.
1211 This cut can be changed from star.rc (see example inside) by
1212 the "SparkCut" directive
1213
1214 - star: Star displays now the average individual pixel-rate (IPR) versus
1215 time and the average discriminator threshold (DT) of all pixels.
1216
1217 - optim: fixed a problem with the optim-macros which was due to a bug
1218 in the new phrase parsing
1219
1220 - ganymed: To get a nice FalseSource plot (instead of the all-information
1221 debug plot displayed as a standard plot) use the context menu
1222 somewhere between the two upper plots, click on "DrawNicePlot"
1223 and enjoy the result. (It is the same context menu which contains
1224 the other options)
1225 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1226
1227 - ganymed/optim/train: The cut program, trainings- and optimization
1228 macros could run with less files found than expected from the
1229 sequence-files. No the execution is stopped in this case.
1230
1231 - ganymed: now stores the dataset in the output file with all information
1232 contained (as sequence number, sequence path, data path) so that the
1233 used dataset file can be recreated complete from the output
1234
1235 - sponde: now also allows the uasge of random forest
1236
1237 - sponde: added a plot showing the cut efficiency
1238
1239 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1240 errors (eg. effecting the collection area) because the errors of the
1241 two histograms were swapped in the calculation, which makes a difference
1242 in the case the histograms contains weighted events. Aditionally the
1243 totalarea was incorrectly taken into account, which results in too small
1244 errors, which makes a difference at low statistics were the errors
1245 or the collection area dominate.
1246
1247
1248
1249 *** Version 0.10.3 (2006/10/23)
1250
1251 - database: Implemented ObservationMode flag in websites.
1252
1253 - database: For sequences there is now also the stoptime available on the
1254 websites.
1255
1256 - database: Removed ManuallyChanged flag from sequence-info websites,
1257 as it is not needed anymore with the new sequence building algorithm.
1258
1259 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1260 Class for calculation of confidence intervals (upper limits).
1261 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1262 Please read the class instruction of TRolke for more information.
1263
1264 - general: The programs now return 0xfe if the requested resource file
1265 doesn't exist.
1266
1267 - general: Errors comming from root itself are now not output to
1268 stderr anymore but to our default (colored) log-stream.
1269
1270 - general: Changed the interface to TFormula such that now everything
1271 is parsed by TFormula, which should allow to use phrases even
1272 without paranthesis correctly parsed.
1273
1274 - callisto: replaced the AdHoc number of effective integration slices
1275 in the digital filter by an average of the correct number, averaged
1276 over all possible set of weights. This also gives correct numbers
1277 for the lo-gains which were totally wrong before.
1278
1279 - callisto: drastically reduced memory consumption by not storing
1280 all intermediate calibration results in memory anymore (we might
1281 write them into a file in the future)
1282
1283 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1284 debug plot displayed as a standard plot) use the context menu
1285 somewhere between the two upper plots, click on "DrawNicePlot"
1286 and enjoy the result. (It is the same context menu which contains
1287 the "DrawAll" option)
1288 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1289
1290
1291
1292 *** Version 0.10.2 (2006/10/15)
1293
1294 - general: changed the building of the sequence files such, that
1295 the source-/project name in case of wobble-sources is not the
1296 source/project of the first data run anymore but the new generalized
1297 wobble source/project
1298
1299 - general: Added some functions to MAstro to calculate sun and
1300 moon properties
1301
1302 - general: Added two new macros (starvisday.C and starvisyear.C)
1303 which allow to plot the visibility of several stars in one day
1304 or of one star along one year
1305
1306
1307
1308 *** Version 0.10.1 (2006/10/11)
1309
1310 - general: HTML logging output was distorted... fixed.
1311
1312 - general: Changed the writing of the sequencefiles such that only
1313 as many pedestal files as giving at least 1000 pedestal events which
1314 are nearby the first calibration run are used as pedestal runs
1315
1316 - sponde: In the calculation of the collection area(s) and the
1317 distribution for MOnte Carlo and estimated energy the error
1318 calculation was wrong because root didn't take the errors
1319 properly into account... fixed.
1320
1321
1322
1323 *** Version 0.10 (2006/10/10)
1324
1325 - general: all executables now check consistency of the root version
1326 installed with the root version used for compilation. The return
1327 code in this case is 255.
1328
1329 - general: The algorithm to build seqeunces has been redesigned
1330 completly. It is now more flexible in terms of a resource file
1331 resources/sequences.rc which can be used to partly overwrite
1332 the default algorithm and defined the important part of the
1333 algorithm. It also takes correctly into account several ways
1334 of taking wobble-data. Currently the new algorithm doesn't take
1335 the number of pedestal events anymore into account (so a sequence
1336 could have much less than 1000 pedestal events and data runs are
1337 no-more used instead)
1338
1339 - general: a lot of small changes to make the code compatible with
1340 root 5.12/00 and gcc 4.1
1341
1342 - general: Fixed some warnings thrown if more warnings are switched
1343 on in the compiler
1344
1345 - general: Added a function to MMath which returns the Median of
1346 the distribution abs(y[i]-median) but at 68:32 division instead
1347 of 50:50, which is somehow the median counterpart of the rms.
1348
1349 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1350 even if they are compressed with gzip (recommended compression
1351 is with "-1")
1352
1353 - showplot:
1354 + batch mode creation of image files now works with root 5.12/00
1355 + added support for writing bmp (though it never produces
1356 bmp which can be read by programs like xv or gimp)
1357 + added support for xml
1358 + added new option to start the display with a different size, by
1359 --display-width=nnn or --display-height=nnn
1360 + added options to define the canvas size when the display is started
1361 --canvas-width=nnn or --canvas-height=nnn
1362 the option can also be used for batch-mode conversion
1363 + added an option which automatically fits the display size to the
1364 desktop-size: --auto-size
1365
1366 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1367
1368 - merpp: allow the reports to have 1000ms due to a bug in the camera
1369 program.
1370
1371 - callisto: New swapped pixels have been found and corrected. For
1372 details see MRawRunHeader::FixAssignment()
1373
1374 - callisto: Callisto now raises an error if one of the input files could
1375 not be opened.
1376
1377 - callisto: In some rare cases it could happen that in the signal
1378 extraction of the digital filter the extractor returned nonsense
1379 results due a wrong initializion of a variable (this happens in
1380 cases in which the extracted signal is exactly zero or the
1381 digital filter couldn't slide because of a too small extraction
1382 window, which could happen in the lo-gain extraction)
1383
1384 - callisto: The lo-gains have been marked as valid in some cases
1385 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1386 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1387 smaller than the number of slices (fLoGainWindowSize) needed
1388 by the lo-gain extractor
1389
1390 - callisto: Updated absolute calibration constants (muon calibration)
1391
1392 - callisto: fixed a bug which caused the hi-gain saturation not
1393 to be handled properly in the spline (the position of the
1394 saturation was calculated incorrectly)
1395
1396 - callisto: fixed a bug which gave weird results if hi- _and_
1397 lo-gain could not be extracted properly. In some cases hi-
1398 and lo-gain have not been extracted at all and the random result
1399 got calibrated. In other cases the hi-gain was saturating and the
1400 lo-gain has not been extracted. For this a completly arbitraty
1401 scale factor was applied to the result from extracting the
1402 charge of the saturating hi-gain.
1403
1404 - callisto: improves handling of extracted signal if lo- and/or
1405 hi-gain could not be extracted properly. If no appropriate
1406 calibration of either the signal or the arrival time is possible
1407 the pixel is now markes as unsuitable instead of estimated.
1408
1409 - callisto: Fixed a problem in the spline extraction which gave
1410 weird results if the signal was extracted from the first (and
1411 highest) slice (as a workaround extraction from the first
1412 slice has been forbidden)
1413
1414 - callisto: Fixed a bug regarding the use of the QE which doesn't
1415 effect the result because the default is used anyhow.
1416 (The bug was there since 14/07/2005)
1417
1418 - callisto: Changed the default for fgLoGainStartShift to -2.4
1419
1420 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1421 factors to be always 10 for all pixels as soon as the first
1422 calibration update has happend.
1423
1424 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1425 was off by more than one slice (which gives wrong values for
1426 pixels which have saturated the hi-gain) This was a problem
1427 mainly for timing studies, not so much for the automatic standard
1428 analysis. Also the values for the Spline have been changed slightly:
1429 + Digital Filter from 1.70 to 0.95
1430 + Spline from 1.39 to 1.30
1431 The numbers were sorted out by an extensive test in the
1432 test-database.
1433
1434 - callisto: Removed the tab showing the average calibrated arrival
1435 time. It never gave useful information.
1436
1437 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1438 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1439 and both were extracted because the hi-gain was above the
1440 LoGainSwitch.
1441
1442 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1443 lo-gain pulse position (after application of LoGainOffset, which
1444 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1445 have saturated and both were extracted because the hi-gain was above
1446 the LoGainSwitch.
1447
1448 - callisto: After extensive tests a new threshold level for determination
1449 of the pulse position has been found at 50phe. This is due to the
1450 fact that for lower pulses the arrival time changes its average
1451 behaviour dramatically. It tends to the average of the extraction
1452 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1453
1454 - callisto: Added two more plots to the calibration part. The average
1455 extracted signal and the average extracted arrival time as
1456 extracted by the signal extractor (This can help debugging problems
1457 because it doesn't involve a fit)
1458
1459 - star: changed the fit for the effective on time such that initial
1460 values are calculated automatically now instead of using build
1461 in values. This makes the fit more indepedant of the underlaying
1462 rates. With a test of ~350 sequences in the test database it could
1463 be shown that the new fit gives the same result +/-1sek.
1464 The highest deviation was +5s the lowest -10s. You can now control
1465 the bahaviour with two resource values:
1466 MHEffectiveOnTime.FistBin: 3
1467 MHEffectiveOnTime.NumEvents: 12000
1468 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1469 from the resulting gamma candidates
1470
1471 - star: The Center histogram in MHHillas is now by default displayed
1472 with the colz draw-option
1473
1474 - ganymed: now produces valid error codes if failed
1475
1476 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1477 with the option "hadronness" instead of "area" or "both" if
1478 you want to use both cuts. The hadronness cut includes a fixed
1479 cut in hadronness (index 8) and a fixed cut in size (index 9).
1480
1481 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1482 the M3Long of the anti source to be not properly evaluated
1483 (actually is was evaluated as a unique random number) in case
1484 of optimization with anti-theta cut switched on. This might have
1485 lead to improper, but not necessarily wrong, optimization results.
1486
1487 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1488 how to use random forest
1489
1490 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1491 ganymed_onoff.rc. Seems to be unintentional that they were different.
1492
1493 - sponde: Since the introduction of the possibility to define a
1494 normalization energy instead of using the integral the default
1495 was not using the integral anymore but a normalization energy of
1496 1GeV. It is now the integral again.
1497
1498 - sponde: Fixed a problem in the weighting which did not allow
1499 a MC slope of -1.
1500
1501
1502
1503 *** Version 0.9.6 (2006/05/24)
1504
1505 - general: changed the binning of the azimuthal profile of the camera
1506 such that it is aligned with the 60deg boundaries.
1507
1508 - merpp: better handling of problems with the TH, TD part of the
1509 CC-REPORT for files older than 200507190 and 200412210
1510 respectively
1511
1512 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1513
1514 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1515
1516 - callisto: if an arrival time is extracted outside the fadc range is
1517 was set to the boundary before. Now a random number is assigned
1518 instead to avoid unfortunate coincidences of arrival times just
1519 by this arbitrary value.
1520
1521 - callisto: added a new option to callisto.rc which allows
1522 to set the maximum arrival time difference allowed for the
1523 badpixel algorithm to determin whether a pixels belongs to a shower:
1524 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1525
1526 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1527 to 0.9 as suggested by Stefan due to a recent study on the fraction
1528 of pixels surviving the image cleaning
1529
1530 - callisto: switched off error in case of "pulse is too much to the left"
1531
1532 - callisto: The extraction window is not adapted anymore. This means that
1533 the pulse is extracted from the full range. The draw-back is that the
1534 background (pedestal) will become slightly higher. Switching on/off
1535 the PulsePosCheck in the callisto.rc only effects filling the
1536 histograms.
1537 WARNING: If the pulse is too much to the left data is calibrated!
1538 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1539 in the database to make sure that your data is valid!
1540
1541 - star: Show also the number of stars correlated correctly by the
1542 starguider
1543
1544 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1545 than one off-source region in wobble-mode. To use it add the following to
1546 your ganymed_wobble.rc:
1547 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1548 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1549 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1550 + Cut1.ThetaCut: None
1551 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1552
1553 - ganymed: in the case the latest report is older than a default (currently
1554 one minute) and the current report will be skip the starguider
1555 correction and calibration will be reset. The maximum age can be
1556 setup from ganymed.rc by (minutes):
1557 MPointingDevCalc.MaxAge: 1.5
1558
1559 - ganymed: A first implementation showing all size-bins for the theta-sq
1560 resp. alpha-plots in a single tab automatically
1561
1562
1563
1564 *** Version 0.9.5.1 (2006/05/05)
1565
1566 - general: Added a new option "zdiff" to the Makefile which runs
1567 "cvs diff" as "make diff" would do, but with compression
1568
1569 - general: accelerated MTFillMatrix (used for eample in all training
1570 and optimization macros) by skipping some obsolete calles in the
1571 eventloop the first and second loop could be accelerated by ~20%
1572
1573 - general: Added a missing feature in the MFilterList class which
1574 prevented MFEnergySlope from working correctly in trainenergy.C
1575
1576 - general: Accelerated the random forest training and usage a bit
1577
1578 - merpp: Adapted to new raw data file format version 6
1579
1580 - merpp: fixed a problem with reading the starguider reports
1581 after 6.3.2006
1582
1583 - callisto: At some times six pixels had to be exchanged manually in the
1584 data. If the pixels to be swaped are both not found, an error was raised
1585 and calibration was stopped. Now it is assumed they are intentially not
1586 mapped and the Error has been changed to a Warning.
1587
1588 - star: Added new image cleaning based on the arrival time of the shower.
1589 The new cleaning can be accessed using the parameter "Time" instead of
1590 the the old one (like "Absolute) in the star.rc-file.
1591 Recommended parameters:
1592 + MImgCleanStd.CleanLevel1: 8.2
1593 + MImgCleanStd.CleanLevel2: 5
1594 + MImgCleanStd.CleanRings: 2
1595 + MImgCleanStd.KeepSinglePixels: No
1596
1597 - star: Simplified the calculation of the effective on time. By letting
1598 the fit start in the third bin the result should become more stable.
1599 The fit quality is now ignored for the theta-plot which is not used
1600 in the analysis later. Still better pre-cut which, for example,
1601 remove events triggered by car-light (rate changing on a short
1602 time-scale) are missing.
1603
1604 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1605 for optimization (kWeakSource) which is suggested by the Berlin
1606 people for weak sources.
1607
1608 - macros: plotdb.C:
1609 + if no dataset and no time-interval is given only sequences with
1610 an effective on-time above five minutes are plotted anymore
1611 + added a new tab "RelTime" displaying the relative on-time
1612 (effective on-time divided by the observation time)
1613
1614 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1615 the optimization became a lot faster
1616
1617 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1618 To display them just delete the pads displayed on top.
1619
1620 - ganymed: fixed a bug which could cause strange behaviour in wobble
1621 mode if no starguider information was available due to an incorrect
1622 initialization of the starguider calibration
1623
1624 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1625 be changed from within the plot. It can also be setup from the
1626 resource file using:
1627 + MHDisp.fScaleMin: 0.325
1628 + MHDisp.fScaleMax: 0.475
1629
1630 - ganymed, showplot: Fixed a problem with the fit to the off-data
1631 (HistOff) which could cause a time lag or an inifinite loop.
1632 The bug did not effect the results at all.
1633
1634 - sponde: Added a new tab showing the effective collection area after
1635 trigger (including the software trigger)
1636
1637 - sponde: MMcSpectrumWeight has a new option which allows to define
1638 the scaling factor not by the integral of the events but at
1639 a defined energy:
1640 e.g. MMcSpectrumWeight.NormEnergy: 200
1641
1642 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1643 eventloops the loop could be accelerated by ~20%
1644
1645
1646
1647 *** Version 0.9.5 (2006/03/13)
1648
1649 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1650 and added the standard Disp-parametrization
1651
1652 - macros: added a new macro datacenter/macros/plotstat.C allowing
1653 to plot statistics about the data processing
1654
1655 - macros: added a new macro to plot the muon correction coefficients
1656 versus period (macros/plot/mucal.C)
1657
1658 - showplot: path inflation for ganymed files was broken
1659
1660 - callisto: Fixed an important bug. When the number of saturating pixels
1661 were calculated the bad pixel information already available from the
1662 calibration was ignored. This yields wrong values in case pixels
1663 are broken and saturate all the time or randomly.
1664
1665 - callisto: Updated Muon calibration constants. Spline data now also uses
1666 different values for different periods
1667
1668 - star: The time-evolution shown in the effective on-time plot now displays
1669 the axis range (if there are no holes it should be similar to the
1670 effective on-time)
1671
1672 - star: Added two new image parameters:
1673 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1674 the three pixels next to the center of gravity and the size
1675 + MNewImagePar.fConcCore: The ratio of the signals of all
1676 pixels inside or touching the ellipse and the size
1677
1678 - ganymed: now stops in requested source isn't found in catalog file
1679
1680 - ganymed: Many improvements to the phi-plot in wobble mode:
1681 + with a template the ideal background is displayed
1682 + a possible camera inhomogeneity is taken into account
1683 + the anti theta cut is better supported
1684 + the phi cut is automatically calculated from the theta cut
1685 See the examples in ganymed_wobble.rc for more details.
1686
1687 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1688 times the bin-width instead of the absolute energy
1689
1690 - ganymed: New cuts for on/off and wobble mode
1691
1692 - ganymed: The smearing of the False Source plot has been increased
1693 to 0.06
1694
1695 - ganymed: The starguider calibration can now be changed from the
1696 resource file.
1697 See the examples in ganymed*.rc for more details.
1698
1699 - ganymed: added a new option for on-/off-observations
1700 MJCut.RandomSourcePosition
1701 If switched on the distribution of observation time of the source
1702 position in the camera is calculated from the on-data and randomly
1703 applied with this distrbution to the off-data.
1704
1705 - ganymed: by skipping some obsolete calles in the eventloop the
1706 first and second loop could be accelerated by ~20%
1707
1708 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1709 position in the off-data randomly according to its distribution in the
1710 on-data.
1711
1712
1713
1714 *** Version 0.9.4.3 (2006/02/13)
1715
1716 - general: Fixed a bug in most of the programs which prevented the
1717 compile date in the startup message to be displayed
1718
1719 - general: Simplified program calls. The following abbreviations
1720 are now possible:
1721 showlog callisto 55599
1722 showplot signal 55599
1723 star 55599
1724 callisto 55999
1725 ganymed 2
1726 In this cases the corrsponding root-, log-, sequence- or dataset-
1727 filename is automatically compiled using the default datacenter
1728 paths ("/magic/*")
1729
1730 - general: Fixed a long outstanding bug which made axis tick marks
1731 disappear if MDataFormula was used (eg. abs(x))
1732
1733 - general: Updated MMath with new functions to calculate the results of
1734 a exponential, logarithmic and powerlaw fits analytically.
1735
1736 - general: Updated some macros with comments:
1737 + macros/optim/optimdisp.C
1738 + macros/optim/optimenergy.C
1739 + macros/optim/optimwobble.C:
1740
1741 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1742 files) now allows adding a pre-cut like in the optimization. E.g. this
1743 is useful to perform g/h-separation cuts before training the random
1744 forest.
1745
1746 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1747 correctly assigned in the raw data assignement table. A fix to correct
1748 the assignment tabel have been implemented.
1749
1750 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1751 by 90, 180 and 270 deg.
1752
1753 - general: the macro plotdb.C now allows to highlight sequences belonging
1754 to a datset. For more details see the descritions in the macro.
1755
1756 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1757 of the display, it gave wrong results espacially for big sizes.
1758 Now the embedded canvas should always have a ratio width/height=3/2.
1759 The "Size" options have been updated with values fitting the 3/2
1760 size ratio.
1761
1762 - RanForest:
1763 + Updated the random forest classes to support also the
1764 regression method implemented by Thomas H.
1765 + added new tutorial macro how to train the random forest
1766 for energy estimation (macros/optim/rfenergyest.C)
1767 + new classes to train the random forest (still in development)
1768 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1769 + new tutorial macros for random forest training in macros/train
1770 trainenergy.C, traindisp.C, trainseparation.C
1771
1772 - mars: now allows to setup a cut in the resource file mars.rc to choose
1773 the events to be displayed, eg:
1774 Cut.Condition: {0} && {1}
1775 Cut.0: MHillas.fSize>100
1776 Cut.1: MHillas.fSize<900
1777
1778 - merpp: Made aware of the new .rep format 200510250. This includes
1779 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1780 the discriminator thresholds (MCameraTD) and the disciminator
1781 delays (MCameraTD). All of them come with the CC report and are therefor
1782 written to the CC tree.
1783
1784 - callisto: fixed a bug in the calculation of the arrival times in
1785 the Digital Filter. They were all shifted by the same amount
1786 fHiGainFirst. This caused an offset in the order of the position of
1787 the left border of the extraction window in the times calculated
1788 from high-gain and from low-gain. The bug effected only the absolute
1789 arrival times. The bug was there since 30.1.2005.
1790
1791 - callisto: Changed the ExtractionWindow for the pulse position check
1792 such that the camera inhomogeneity becomes as less as possible and
1793 comparable to the pulso position check switched off. More details
1794 on the study will be given at our result web-page.
1795
1796 - ganymed: ganymed.rc, ganymed_onoff.rc:
1797 changed to new cuts trained with 1ES1218 and Crab-data
1798 for maximum sigma*log10(excess)
1799
1800 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1801 a new option was implemented to estimate Disp (CalcDisp)
1802
1803 - ganymed: Implemented two new options which allow
1804 to overwrite the default path to search for the sequence files
1805 --ins=/magic/sequences
1806 and where to search for the image data
1807 --ind=/magic/data/star
1808
1809 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1810 dx/dy from the resource file by
1811 MSrcPosCorrect.Dx
1812 MSrcPosCorrect.Dy
1813
1814 - ganymed: fixed reading the source catalog. Only as many chars
1815 as the requested source name had were compared (If a source
1816 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1817 were requested it could happen that the coordinates of
1818 "1ES1218" were read) The source coordinates are now printed
1819 in addition to its name to the logging output.
1820
1821 - ganymed: changed the background fit in the case of a ThetaSq function
1822 from a polynomial to a exponential, this should give a big improvement
1823 for on-only analysis'
1824
1825 - ganymed/sponde: Calculation of the error of single size-/energy-
1826 bins now uses Li/Ma (5) instead of LiMa (17)
1827
1828 - sponde: Added a plot E^2*dN/dE
1829
1830 - sponde: The energy estimator plot should now show values like
1831 they are commonly used.
1832
1833 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1834 (a powerlaw with cutoff didn't work before)
1835
1836
1837
1838 *** Version 0.9.4.2 (2005/10/01)
1839
1840 - general: added new tutorial macro macros/tutorials/threshold.C:
1841 how to calculate the threshold
1842
1843 - general: added a new game. Start it from the interpreter with
1844 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1845 and MagicReversi)
1846
1847 - general: neighbor pixels in MGeoms are now sorted clockwise
1848
1849 - merpp: made aware of new format 20050829-0
1850
1851 - callisto: New scale factors from muon analysis, stored in new
1852 resource file resources/calibration.rc
1853
1854 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1855 the eventloop if something went wrong. This is necessary for the
1856 automatic processing
1857
1858 - callisto: Implemented a new treatment for the time information
1859 developed by S.Ruegamer, this should give much better response than
1860 the old very primitive algorithm. This is especially important
1861 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1862 treatment was buggy! As neighbor pixels to interpolate the
1863 arrival times always the pixels 0 to 5 were taken)
1864
1865 - callisto: In addition to the new treatment of arrival times the
1866 decision of the treatment whether a pixel contains shower
1867 information or not is used to improve the signal interpolation
1868 further. Previously interpolated pixels showed a non-zero signal
1869 do the peak searching signal extractors. Having a signal pixel
1870 beside raised the signal above the cleaning level. Thus the
1871 pixel survived cleaning to often but with a too low mean signal.
1872 By replacing empty pixels with a gaus (mean and rms from the
1873 corresponding Area entries in MPedPhotCam) this effect can
1874 be supressed.
1875
1876 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1877 got lost when the events were stored by the calibration... fixed.
1878 (This was no problem for normal image cleaning because the pixel
1879 content was artificially set to 0 not surviving standard cleaning
1880 algorithm)
1881
1882 - callisto: Fixed a bug which caused the random and peak-search pedestal
1883 extracted with an extractor to be exchanged for the first (roughly)
1884 500 events (*Extractor and *ExtractorRndm).
1885 (They were simply exchanged in callisto.cc) This bug might have been
1886 introduced in Mars 0.9.4 when the order of calculation of the two
1887 types of pedestal in callisto got exchanged. The bug only effects
1888 the first seconds of data of each sequence.
1889
1890 - star: Taking the arrival time of Muons into account the calculation
1891 of the parameters could be made independant of the noise
1892 (pedestal rms). The dependance was due to the bias of the peak search
1893 extractor. Now only a ZA dependamcy is left which is not yet fully
1894 understood.
1895
1896 - ganymed: The sequences were still not sorted correctly in any case,
1897 because they were sorted by the full qualified path name. Now they
1898 are sorted by their sequence number.
1899
1900 - ganymed: new values for the spark-event-cut
1901
1902 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1903
1904
1905
1906 *** Version 0.9.4.1 (2005/08/18)
1907
1908 - callisto: fixed some problems with the calibration in case of
1909 inteleaved events. Therefor the final and some intermediate
1910 fits are skipped which would take place on partly filled #
1911 histograms and gave wrong results or failed completely.
1912
1913 - callisto: If the intermediate finalization of the histograms
1914 calculating the mean charge of the calibration signal fails
1915 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1916
1917 - ganymed: Fixed some bugs which caused problems in On-only mode.
1918 Still the false source plot doesn't give reasonable results.
1919
1920
1921
1922 *** Version 0.9.4 (2005/08/05)
1923
1924 - general: Fixed the ZA binning. It did not correctly fit the
1925 MC binning
1926
1927 - general: Added a class to correct for the missfocussing in
1928 April (MSrcPosCorrect)
1929
1930 - general: Random Forest energy estimator should now work properly
1931
1932 - general: MHCamera now displays the profiles in deg instead of mm
1933
1934 - general: MH::SetPalette offers a lot of new palettes
1935
1936 - general: MHillas - the case of CorrXY==0 is now handled properly
1937
1938 - general: implemented the possibility to change the line and
1939 marker style of a sky-grid drawn by MAstroCatalog
1940
1941 - general: Runs in sequences and datasets are now automatically
1942 ordered (it is assumed that the order of their filenames correctly
1943 represents the order of observations) to ensure correct reading
1944 of the subsystem data
1945
1946 - general: Runs cannot be added to a sequence twice anymore. Also
1947 Sequences cannot be added twice anymore to a dataset.
1948
1949 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1950 It gave wrong results by 1./2pi
1951
1952 - showplot: got a new option to start a root interpreter, too
1953
1954 - mars: now displays a rough estimate of Disp and the third moment
1955
1956 - mars: now displays the event time MTime if available
1957
1958 - mars: show muon parameters graphically
1959
1960 - mars: now the file to open can be given as commandline
1961 argument
1962
1963 - merpp: Added support for new arehucas version >= 200507190
1964 implementing values for three temperature sensors in the
1965 counting house (MCameraAUX) and the name of the HV settings file
1966 (MCameraHV).
1967
1968 - merrp: Also fixed some problems with wrong versions numbers stated
1969 by arehucas and implemented some fixed for old versions (<200407070)
1970
1971 - callisto: MCalibrationHiLoCam can now be printed from its context
1972 menu, eg in the TBrowser
1973
1974 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1975 - 1.39 (MExtractTimeAndChargeSpline)
1976 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1977 This is important mainly for timing studies.
1978
1979 - callisto: Changed limits in MHCalibrationChargeCalc from
1980 - -100.125 to -98 (fgChargeHiGainFirst)
1981 - 1899.875 to 1902. (fgChargeHiGainLast)
1982 - -100.25 to -99 (fgChargeLoGainFirst)
1983 - 899.75 to 901. (fgChargeLoGainLast)
1984 Introduced new limits:
1985 - fgNumLoGainBlackoutLimit: 0.05
1986 - fgLoGainBlackoutLimit: 3.5
1987 - fgLoGainPickupLimit: 3.5
1988
1989 - callisto: The handling of automatic weights for the digital filter
1990 has been improved. There are now new calibration weights special
1991 for Monte Carlo calibrations.
1992
1993 - callisto: Updated Muon scale with latest results (1% difference
1994 for most data, 5% for Mar/Apr'05)
1995
1996 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1997 was saturated and the blackout-events in the low-gain exceed the
1998 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1999 This excludes those pixels which have a saturating high-gain
2000 channel, but the low-gain switch does not switch often enough
2001 to make the distribution reliable.
2002
2003 - callisto: fix a bug counting the number of saturated events. Up to now,
2004 the number of saturated slices was counted (which is one for a not too
2005 high number), but for some (pathological) pixels, many more slices
2006 saturated and produced wrong limits.
2007
2008 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2009 + MCalibrationRelTimeCam.CheckFitResults: Yes
2010 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2011 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2012 + MCalibrationRelTimeCam.CheckOscillations: Yes
2013
2014 - callisto: introduce max. number of events for intercalibration,
2015 the rest gets skipped. Default: 4096
2016 The calibration causes too many un-reliable pixels if more
2017 than about 5000 events are treated (@500 Hz) because of the
2018 mode hopping of the VCSels. However, in the past, some
2019 calibration runs have been taken (erroneously) with more
2020 than 5000 events, especially the intensity scans where
2021 a good precision is needed.
2022
2023 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2024 photo-electrons for the spline extractor by 1-2% (correctly).
2025
2026 - callisto: The intercalibration is now done using a full f-factor
2027 method instead of a simple update. This makes things slower but
2028 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2029 changes.
2030
2031 - callisto: MPedestalY3 now uses the same extraction range as the data
2032 as calculated by MPedestalY2
2033
2034 - callisto: A check of the fraction of allowed unsuitable (10%) and
2035 unreliable (30%) pixels has been addded when the conversion is
2036 calculated from interleaved events
2037
2038 - star: fixed a bug which caused MEffectiveOnTime containers not to
2039 be written. In the worst case they were skipped almost all, in the
2040 best case they were all ok. It depends on how often the new value
2041 was assigned just with an event which was skipped later by another
2042 task
2043
2044 - star: new histograms MHPointing and MHRate
2045
2046 - star: New tab (Currents) displaying the time evolution of the mean
2047 DC currents
2048
2049 - star: New tab (MeanRms) displaying the time volution of the mean
2050 Pedestal Rms
2051
2052 - star: Output now contains MReportStarguider
2053
2054 - star: Improved muon analysis. Due to the absense of a constant
2055 for the gaus fit for arc width and the fact that the arcwidth
2056 plot was a histogram instead of a profile the resulting psf
2057 became pedestal rms dependant
2058
2059 - ganymed: added new plot (MHPhi) for wobble mode as described in
2060 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2061
2062 - ganymed: corrects now (correctly?) for the misspointing in
2063 May/April 05
2064
2065 - ganymed: Two new default templates for ganymed.rc are avilable:
2066 ganymed_onoff.rc and ganymed_wobble.rc
2067
2068 - ganymed: The first version of MFMagicCuts has been released
2069
2070 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2071
2072 - ganymed, sponde: There are two new options to determin the number
2073 of bins for the signal region (NumBinsSignal) and the number of
2074 total bins (NumBinsTotal) in the MHThetaSq histogram
2075
2076 - ganymed: optimized palettes for MHDisp
2077
2078 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2079 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2080 sqrt(2) to large
2081
2082 - ganymed: The false source plot (MHDisp) is now based on Disp
2083 and a background model determined in the first loop is
2084 subtracted
2085
2086 - ganymed: MFMagicCuts are now available in the cvs. The correct
2087 solution for the disp ambiguity problem is now calculated using
2088 the third moment. The third moment cut therefor is skipped.
2089
2090 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2091 already determined by the third moment along the major axis and
2092 so its actual sign is aligned along the major axis of the shower.
2093
2094 - ganymed: If starguider data is available it is taken into account
2095 when calculating the source position. This is especially important
2096 for wobble data at high zenith angles and culmination data.
2097
2098 - ganymed: If available the starguider data is taken into account as
2099 good as it is possible without a starguider calibration. To switch
2100 it off add
2101 MPointingDevCalc.MaxAbsDev: -1
2102 to your ganymed.rc
2103
2104 - sponde: the zenith angle distribution is now weighted instead of
2105 choosen by default. This gurantees higher statistics in the highest
2106 and lowest energy bins. To switch this behaviour off use...
2107
2108 - sponde: now automatically displays the energy threshold
2109
2110
2111
2112 *** Version 0.9.3 (2005/06/03)
2113
2114 - general: MMcEvt now derived from MMcEvtBasic which should
2115 have no influence on compatibility with older camera files
2116
2117 - general: Implemented a new option to MReadReports which allows
2118 to force reading of the first event of some trees (eg. Drive-tree)
2119 before any other tree.
2120
2121 - general: Made a fix to MPointingPosCalc which assumes that the
2122 run-type is real-data if Process is called before ReInit, such
2123 that also the very first Drive-events in a run are treated
2124 correctly.
2125
2126 - shoplot now displays the filename in the title bar of the window
2127
2128 - merpp: new options: --auto-time-start --auto-time-stop which
2129 allow to cut updating with slow-control at the start- or
2130 (previousle --auto-time only allowed: and) stop-time of
2131 the run stored in the runheader.
2132
2133 - callisto: changed default of fgFallTimeHiGain in
2134 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2135 already set as default in callisto_Dec04Jan05.rc
2136
2137 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2138 now changes the filename for new weights automatically for
2139 cosmics, MC and for different calibration colors.
2140
2141 - callisto: a problem with the order of some code cause the
2142 name of the weights file in MPedestalY2 to be ignored.
2143 Wrongly the calibration_UV weights were used instead
2144 of the cosmics weights set in callisto.rc.
2145
2146 - callisto: should allow ct1 pulser data when the color is
2147 explicitly set also for pretty new runs
2148
2149 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2150 to introduce an additional scale factor (should be around 1)
2151 to adapt for slight deviations in different extractors from
2152 the MC calibration. For MC calibrations the scale factor
2153 is fixed to 1
2154
2155 - callisto: MFCosmics should handle very high signals a bit
2156 more accurate now
2157
2158 - callisto: when calculating the mean pedestal rms for different
2159 pixel sizes or sectors also kUnsuitableEvt is now taken into
2160 account - not only kUnsuitableRun
2161
2162 - callisto: '-raw' option is now the default
2163
2164 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2165 This has the advantage that mean values in the calibration (eg
2166 arrival times) are calculated more accuratly.
2167
2168 - callisto: In the resource file callisto_Dec04Jan05.rc
2169 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2170
2171 - callisto: new Hi-/Lo-Gain intercalibration constants
2172 hilocalib_sp1.root and hilocalib_sp1_mc.root
2173
2174 - callisto: changed default for MJPedestalY2.MaxEvents
2175 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2176
2177 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2178 has changed from 9.0 to 6.0. This is necessary to exclude two very
2179 ringing pixels in September which - when kept - destroy the image
2180 cleaning around them (Markus G.)
2181
2182 - callisto: (!) The Muon analysis of all data taken so far has
2183 suggested that different extractors give slightly different
2184 absolute results after calibration, due to there different
2185 handling of the calibration- and cosmics pulse shape. Although
2186 the over all calibration seems to be a bit to pesimistic (or
2187 the MC seems to be a little bit - 3-5% - too much attenuated).
2188 There for correction factors have been introduced which correct
2189 the calibration constants by
2190 0.956937799 for Digital Filter (callisto.rc)
2191 and
2192 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2193 calibration. The main advantage is, that both data types can
2194 be easily analysed together and compared to the same MC sample.
2195 The factors are choosen such, that the reference is now a
2196 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2197
2198 - star: fixed a bug which caused the first bin of the histograms
2199 vs time to disapear in PostProcess. This gave wrong results
2200 on the screen. The output and all following programs not
2201 directly accessing the histograms haven't been affected
2202
2203 - star, ganymed: Made sure that always the first Drive-tree event
2204 is read and Processed before the first data event was read.
2205
2206 - ganymed: implemented the possibility to replace the standard
2207 false source plot with a different one. For example: If
2208 you want to use a Disp based FS plot use the resource:
2209 NameHistFS: MHDisp
2210 For details about the requirements of these plots look
2211 at the corresponding classes
2212
2213 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2214 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2215 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2216 case MAlphaFitter is setup correctly. For On-Only optimization
2217 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2218 RunOn() instead of Run(). For energy estimation MJOptimize
2219 has been replaced by MJOptimizeEnergy
2220
2221 - sponde: The input MC spectrum can now be weighted to fake a
2222 different spectrum. This is done via MMcSpectrumWeight. For
2223 more details see the class description and sponde.rc
2224
2225 - sponde: The paremeter comparsion plots are not scaled by
2226 their entries anymore. Instead the MC plot is scaled by using
2227 the result spectrum of the analysis. If the input MC spectrum
2228 and the result spectrum has different slopes the absolut
2229 normalization is normally wrong.
2230
2231
2232
2233 *** Version 0.9.2 (2005/05/20)
2234
2235 - general: Changed the default paths for calibrated data and image
2236 files. (The implemented access to these files doesn't yet exist)
2237
2238 - general: support for MRunIter has been removed from the job classes
2239 (use the setter functions of MSeqeunce instead)
2240
2241 - general: ProcessFile has been renamed to Process in all job classes,
2242 because ProcessFile is missleading
2243
2244 - general: The storage of the palette in MHCamera is now possible
2245
2246 - general: new bits describing unsuitable and unreliable pixels have
2247 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2248 kDeadPedestalRms, kFluctuatingArrivalTimes
2249
2250 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2251 versions newer than V200404070
2252
2253 - general: support for cc file versions newer than V200504130. Added
2254 support for active loads (MCameraActiveLoad) and central pixel
2255 (MCameraCentralPixel)
2256
2257 - general: added new histograms for image parameters versus size
2258 (MHVsSize)
2259
2260 - general: The eventloop now automatically calls PrintStatistics
2261
2262 - Status Display: Improved support for printing:
2263 + A default can now be set in .rootrc (for more details see
2264 MStatusDisplay::PrintPS)
2265 + A print dialog is opened so that printer and command line
2266 can be canged
2267
2268 - showlog: improved such that it handles different verbosity levels
2269 more accurate now. This mean you can suppress output when
2270 using showlog.
2271
2272 - showplot: improved
2273 + The new graphics formats have been implemented
2274 (pdf, svg, png, jpg and xpm)
2275 + Implemented an interface for printing. Because you can change
2276 the printing command from the command line you can use all
2277 the nice postscript tool. To print a booklet for example call:
2278 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2279 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2280 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2281
2282 - callisto: fixed a bug in the recognition of the calibration bit
2283 pattern. Concerns only intensity calibration. (The strength of the
2284 intensity has been updated in some cases)
2285
2286 - callisto: add a filter against PIN Diode events when running over
2287 calibration runs since some of the recent calibration runs have
2288 been taken with Pin Diode.
2289
2290 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2291 39943, 44833 in the calibration (MCalibColorSet)
2292
2293 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2294 been set to 1e-18 in callisto_Dec04_Jan05.rc
2295
2296 - callisto: in callisto_Dec04Jan05.rc: set value for
2297 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2298 statistics for the calculation of the mean pulse time
2299 of the cosmisc
2300
2301 - callisto: the charge limit in the calibration has been raised
2302 from 2.5 to 4.5
2303
2304 - callisto: new setup read from callisto.rc
2305 + MCalibCalcFromPast.fNumEventsDump
2306 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2307 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2308
2309 - callisto: MExtractTimeAndChargeSpline extractor:
2310 + The integration ranges were shifted by 0.2 FADC slices to the right.
2311 + unreliable handling of floating point values caused different
2312 results on different platform or with different compiler options:
2313 The new algorithm is numerically exact and more accurate because
2314 it doesn't calculate the integration position by multiple times
2315 adding the step-size (which results in numerical uncertanties
2316 exspecially if multiplied with large numbers)
2317 + A lot of fixes have been introduced which effects integrating the
2318 spline at the edges of the valid range. In this case any memory
2319 was randomly accessed. This behaviour can be tested replacing
2320 all MArrayF by TArrayF which perform a range check (but of course
2321 they are a lot slower)
2322 ! No result obtained with the Spline before can be trusted! Due to
2323 random memory access it might by completely random!
2324
2325 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2326 + extraction range in the high gain to 4.
2327 + weights file to cosmics_weights46.dat
2328
2329 - callisto:
2330 + introduce the check for fluctuating arrival times.
2331 + set charge limit to from 2.5 to 4.5
2332 + introduce asymmetric exclusion due to "deviating number of phes":
2333 Default: -9.0 +4.5
2334 + make deviating number of phes unsuitable (see David's findings).
2335
2336 - callisto: fixed the display of unsuitable pixels. The old change
2337 to a real profile in MHCamera broke it.
2338
2339 - callisto: The cosmics filter is used in MJCalibration now
2340 independant of the pulser color (formaly it was used only for
2341 CT1-pulser data). The threshold of number of max empty pixels
2342 has been raised from 2% to 5% in MJCalibration. The maximum
2343 fraction of rejected event is 50% otherwise the calibration has
2344 failed. The filter now ignores unsuitable pixels.
2345 Setup the filter from callisto.rc using "ContCosmics"
2346 (see MFCosmics::ReadEnv)
2347
2348 - callisto: changed default for fgOffsetFromLogain back
2349 from -2.8 to -1.8 in digital filter.
2350
2351 - callisto: for the common extractors
2352 + MExtractFixedWindow
2353 * MExtractTimeAndChargeSlidingWindow
2354 * MExtractTimeAndChargeSpline
2355 * MExtractTimeAndChargeDigitalFilter
2356 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2357 and fResolutionPerPheLoGain
2358
2359 - callisto: Updated the hi-/lo-gain intercalibration constants
2360 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2361 hilocalib_df6.root
2362
2363 - callisto: The default lo-gain extraction window for the
2364 MExtractTimeAndChargeSlidingWindow extractor has been increased
2365 from 6 to 8 to take the stretch of the pusle into account
2366
2367 - callisto (!!!): fixed an important bug in the setting of the
2368 incoming pedestal pointer to the signal extractor extracting
2369 pedestals. This bug caused the pedestals not to be subtracted
2370 correctly in the calibration afterwards. The effect was about 10%
2371 too high conversion factors for the digital filter and the spline
2372 and more than 40% for the sliding window.
2373 The bug existed since end of February! (Markus G.)
2374
2375 - star: added muon support to star. A new tab "MHMuonPar" is
2376 displayed. The lower right plot is an estimate of the point spread
2377 function. A reference value is displayed. To get the real PSF
2378 you must compare with MC. The setup for the muon analysis
2379 is done in star.rc. More informations can be found in
2380 MHSingleMuon and MHCalibParCalc
2381
2382 - star: The weather data is now displayed in star
2383
2384 - star: MEventRateCalc handles the calculation of the event rate more
2385 accurate now in case of the start of a new run inside a sequence
2386
2387 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2388 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2389 changed only minimally
2390
2391 - ganymed: (MJCut and MJOptimize) now displayes the number of
2392 excess events versus size. The energy estimation is done in
2393 MJSpectrum (sponde)
2394
2395 - ganymed: got support for using other variables than Alpha, eg. Theta.
2396 Therefor you need a class deriving from MHAlpha which supports
2397 this variable (one is already existing: MHTheta, which is now the
2398 default in ganymed). It is setup through ganymed.rc
2399
2400 - added a full featured spectrum program (sponde) which reads
2401 ganymed output and monte carlos and compiles a spectrum
2402
2403
2404
2405 *** Version 0.9.1 (2005/04/14)
2406
2407 - Fix bug on the arrival time reconstruction when using Digital
2408 Filter (in some marginal cases (10%) times were reconstructed shifted
2409 by 0.2 slices)
2410
2411 - all executables now return 2 where in previous versions -1 has
2412 been returned (gave problems with shell-scripts)
2413
2414 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2415 also done with a intercalibration input file
2416
2417 - a bug in the time fine adjustment of the digital filter has been fixed
2418
2419 - a lot of small fixes to calling TPad::Divide with a margin==0
2420
2421 - MStatusDisplay now shows the memory usage
2422
2423 - added a memory leak statistic after the eventloop
2424
2425 - MHadronness replaced by MParameterD
2426
2427 - MEnergyEst replaced by MParameterD
2428
2429 - wobble mode can now be switched on from the data-set
2430
2431 - switched on bad pixel detection for a pedestal level
2432 which is more than 5 times the variance
2433
2434 - Fixed default paths to be correct for the new data center
2435
2436 - Fixed handling of drive data. The pointing position in now
2437 copied to MPointingPos inside star for real and MC events
2438
2439 - made sure, that the sequences in a dataset are sorted by
2440 their number to ensure the correct synchronization
2441
2442 - added all resource files necessary to handle spline extraction
2443 of signal for the late 2004 and the early 2005 data
2444
2445 - update the reference lines for the december data
2446
2447 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2448 This is important for the Dec. and Jan. data where the calibration
2449 pulse position changes much.
2450
2451 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2452 filter. This corrects only an defective extraction of the MC at
2453 low-gain signals lower than 90 phes.
2454
2455 - fixed some slowdown in calibrating data with interleaved events from
2456 Jan and Dec. As a workaround made the pretty palette the default.
2457 The inverse Deep Blue Sea has a bug which slows down long calibration
2458 runs a lot.
2459
2460 - implemented new values from new starguider report as defined
2461 in TDAS00-07 V7.1 (eg SkyBrighness)
2462
2463 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2464 in starguider report (If you merpp the same reports with this version
2465 you'll get the correct units (arcmin) but a different result
2466 than with old versions (wrong units))
2467
2468 - Now the status display can also write PNG, JPEG and XPM (other file
2469 formats are still unsupported by root)
2470
2471 - added a lot of scripts and macros in directory datacenter used
2472 for automatic processing
2473
2474
2475
2476 *** Version 0.9 (2005/03/23)
2477
2478 - Calibration is now done autmatically into photo-electrons like
2479 decided by the Collaboration Board
2480
2481 - Reference lines in the display can be read from resource file
2482
2483 - Interlaced calibration events can be handled by callisto
2484
2485 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2486 and applied in callisto.
2487
2488 - class MJCalibTest can be called by callisto
2489
2490 - callisto can now run with three data types: rawdata, rootdata, MC
2491
2492 - added two classes mreport/MReportStarguider.cc and
2493 mreport/MReportStarguider.h for implementing starguider-data
2494
2495 - the output of merpp-update now contains starguider information:
2496 MReportStarguider and MTimeStarguider
2497
2498 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2499 values were lower than they should. This was more visible for high
2500 energy (Size) events.
2501
2502 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2503
2504 - added a new loop to callisto to support the correct extraction of
2505 the pedestal and pedestal rms through the signal extractor
2506
2507 - added class to perform fourier tranformation of a hexagonal structure
2508 (MHexagonalFT)
2509
2510 - added class to perform fourier tranformation of a hexagonal structure
2511 in a tasklist (MHexagonalFTCalc) example: hft.C
2512
2513 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2514 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2515 small pixels, example: extendcam.C
2516
2517 - added possibility to write data to memory (TTree) using MWriteRootFile
2518
2519 - added possibility to read a TTree stored only in memory by MReadTree
2520
2521 - new classes to deal with the interleaved calibration events:
2522 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2523
2524 - implemented filters to callisto to skip calibration events
2525
2526 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2527 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2528 the slices by statistics
2529 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2530 signal extractor without randomization
2531 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2532 with the signal extractor with randomization (extraction window is
2533 randomly fixed)
2534 The three kind of pedestal is not yet implemented (for speed reasons) as
2535 long as nobody really needs it:
2536 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2537 extracted with the signal extractor with randomization
2538
2539 - callisto now finds the pulse position in the data automatically
2540
2541 - implemented data reduction in calibrated data by reducing the precision
2542 of the stored floating point values (pedestal, rms and signal) to
2543 roughly 0.5%
2544
2545 - fixed showplot to make file format conversion (eg. converting a
2546 status display stored in a root file into a postscript file) in
2547 batch mode possible:
2548 showplot -b --save-as-ps[=outfile.ps] infile.root
2549
2550 - Allow class names as part of filter rules, eg
2551 (MFSupercuts) && (MHillas.fSize>100)
2552
2553 - fixed a lot of stuff to allow all programs to process MonteCarlo
2554 camera files.
2555
2556 - enhanced possibility to debug reading of resource file
2557
2558 - MDataChain should handle priorities of operator more
2559 accurate now
2560
2561 - completely revised the container in which the signal is stored
2562 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2563 * the new implementation is faster and
2564 * needs less storage space
2565
2566 - FIRST version which can process Monte Carlos through the
2567 whole chain of programs (callisto, star, etc)
2568
2569 - implemented new image parameters for the border length of
2570 the shower image (MNewImagePar2)
2571
2572 - implemented wobble-mode in ganymed
2573
2574 - new class (MJOptimize) taking care of all optimization processes
2575
2576
2577
2578 *** Version 0.8.6 (2004/10/05)
2579
2580 - New combined signal and time extractor
2581 MExtractTimeAndChargeDigitalFilter
2582
2583 - The Report for the trigger section in the CC run summary has been
2584 updated, and now the IPRs (Individual Pixel Rates) are available.
2585
2586 - new macros for database interaction: filldotrun.C, filldotrbk.C
2587
2588 - added new program which can convert colored output which was redirected
2589 into a file back into colored text (for example to display it with
2590 more): showlog
2591
2592 - added new program to display an MStatusArray of plots (stored with
2593 MStatusDisplay) from a file: showplot
2594
2595 - Added support for Sequences (MSequence). Sequences are blocks of run
2596 files containing the same calibration and belonging to the same
2597 source
2598
2599 - Added a new task (MTaskEnv) which can be used in setup files to switch
2600 between different tasks (for example to choose a signal extractor)
2601
2602 - Implemented automatic file splitting in MWriteRootFile
2603
2604 - After image cleaning an island index is assigned to all used pixels.
2605 The index corresponds to the order of the islands in size.
2606
2607 - added a cleaning which takes signal height _and_ arrival time into
2608 account: probability cleaning (for more details see MImgCleanStd)
2609
2610 - added a cleaning which takes takes the absolute number of photons
2611 times the area ratio as cleaning level
2612 (for more details see MImgCleanStd)
2613
2614 - Changed calculation of image parameters such, that it can be done
2615 for all used pixels or the pixels with a defined island index only
2616
2617 - implemented new image parameters displaying the number of islands,
2618 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2619
2620 - event display in executable changed to support also calibrated files
2621 (done with MJCalibrateSignal)
2622
2623 - added program doing the calibration and the signal extraction
2624 and signal calibration: callisto Most part of the setup is done
2625 by a resource file: callisto.rc
2626
2627 - implemented support for pixels with negative IDs (Raw file format
2628 version 4)
2629
2630 - implemented an new option in merpp (--auto-time) to get the time
2631 range for cc and/or caco data from the run header of the raw data
2632
2633 - New star-program (star and MJStar). Taking calibrated data from
2634 callisto/MJCalibrateSignal as input. The setup is done through
2635 a resource file: star.rc
2636
2637 - Added possibility to setup the eventloop in the mars-executable
2638 Camera Display by a resource file: mars.rc
2639
2640 - The the mars-executable Camera Display can now also read
2641 calibrated data files written by callisto/MJCalibrateSignal
2642
2643 - Added a new class which can calculate the source position in
2644 the camera from a pointing model known to be correct and
2645 the pointing model used for observations (MSrcPosFromModel)
2646
2647 - added a new version of the class calculating the effective on-time
2648 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2649 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2650 MHTimeDiffTheta.
2651
2652 - added the possibility to count how often a signal is above (or
2653 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2654 can replace MHTriggerLvl0)
2655
2656 - added ore convinient ways to set the axis-titles of your histograms
2657 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2658 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2659
2660
2661
2662 *** Version 0.8.5 (2004/08/06)
2663
2664 - new Signal Extractors: MExtractFixedWindowSpline
2665 and MExtractAmplitudeSpline
2666
2667 - implementes interleave in merpp to be able to merpp parts of a file
2668
2669 - implemented force-functionality to merpp
2670
2671 - star display to display star catalogs (MAstroCatalog)
2672
2673 - star display to 'mirror' stars to the camera (MAstroCamera)
2674
2675 - implemented a new cleaning option which allows cleaning scaled with
2676 the real ratio of the rms depending on the pixel size, not only the
2677 square root of the pixelsize (MImgCleanStd, MCameraData)
2678
2679 - removed obsolete MBlind* classes
2680
2681 - Signal extractor taking the AB flag into account implemented (this makes
2682 an odd number of slices for signal extraction possible
2683 (MExtractSignalABcorr)
2684
2685 - implemented a class extracting the pedestal from the raw-data (events)
2686 itself using empty lo-gain (MpedCalcFromLoGain)
2687
2688 - Added mean values to MPedPhotCam
2689
2690 - Added Makefile for Darwin (this OS is NOT officially supported!)
2691
2692
2693
2694 *** Version 0.8.4 (2004/04/19)
2695
2696 - new fast arrival time extractor using cubic splines:
2697 MExtractTimeFastSpline
2698
2699 - implementes multi-argument support in MDataChain
2700 ("pow(a, b)")
2701
2702 - implemented double reference support in MDataChain
2703 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2704
2705 - added support in MF for expressiond like
2706 "MHillas.fWidth<2*<MHillas.fLength"
2707
2708 - MDataChain is now able to support variables like [0], [1], ...
2709 which can be used in fit functions as parameters. The interface
2710 is implemented through the new virtual function
2711 MParContainer::SetVariables
2712
2713 - added new class MArrivalTimeCam/MArrivalTimePix:
2714 Storage containers to hold the ArrivalTime of the camera/pixel
2715
2716 - added new classes for the calibration of relative arrival times:
2717 MCalibrationRelTimePix and MCalibrationRelTimeCam
2718
2719 - added new classes to extract the signal of the blind pixel and the
2720 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2721
2722 - added new classes for the bad-pixels treatment (MBadPixels*)
2723 which are more powerfull than the old ones (MBlindPixel*)
2724 and will replace them.
2725
2726 - added filter against cosmics: MFCosmics
2727
2728 - added new class MArrivalTimeCalc2:
2729 Calculates the arrival time as the signal weighted mean of the time
2730 slices in the maximum window
2731
2732 - added a new macro call pointspreadfucntion.C that fits with a 2D
2733 gaussian the DC spot for an star. It gives you the RMS of
2734 the PSF and the center of the star, very useful for misspointing
2735 studies.
2736
2737 - added support for multi-telescope camera files. Added classes
2738 MStereoCalc and MStereoPar, classes to calculate and store shower
2739 parameters calculated from the data of two telescopes, for the MC
2740 studies regarding the MAGIC clone.
2741
2742 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2743 MC data calibrated in photons instead of ADC counts.
2744
2745 - added three macros to show the calibration and analysis chain of
2746 MC data. The macro starmc.C does both calibration and analysis, producing
2747 an output containing Hillas parameters for each event. The macro
2748 mccalibrate.C does just the calibration and writes out a file containing
2749 pixel information in photons instead of FADC data. The macro starmc2.C
2750 reads in such a file and produces an output with Hillas parameters.
2751
2752 - added MPedPhotCalc to compute pedestals in units of photons, see
2753 macro pedphotcalc.C
2754
2755 - added all class to perform the calibration, see macro calibration.C
2756
2757 - added class MFFT to perform Fast Fourier Transforms
2758
2759 - added class MSimulatedAnnealing to perform simulated annealing
2760 minimizations
2761
2762 - added new macro bootcampstandardanalysis.C which holds the skeleton
2763 of the analysis chain discussed in the december bootcamp.
2764
2765 - added support for DAQ raw data file format V2
2766
2767 - implemented an arbitrary time stamp for the events from raw-data
2768 files with file version<3. It is calculated from the run number,
2769 the date of start and the FADC clock tick from the first module
2770
2771 - implemented the correct decoding of the event time-stamp
2772 coming from the DAQ for raw-data files with file-version>2
2773
2774 - added a new classes storing the pedestals in units of photons:
2775 MPedPhotPix, MPedPhotCam
2776
2777 - added support for DC current files from the camera control
2778
2779 - added support for start- and stop-time when merpping report files
2780
2781 - added MReportCC storing the weather data from the CC-REPORT
2782
2783 - added class to fill trainings and test matrices (MTFillMatrix)
2784
2785 - added a filter performing a software trigger (MFSoftwareTrigger)
2786
2787 - Added classes to perform parts of the standard analysis (Jobs):
2788 + MJPedestals
2789 + MJCalibration
2790 + MJExtractSignal
2791 Note: All of them are preliminary!
2792
2793 - Added Iterator to iterate over files giving only the run-number
2794
2795 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2796 the evolution of a sector vs time
2797
2798
2799
2800 *** Version 0.8.3 (2003/12/05)
2801
2802 - adapted Random Forest classes to allow the use with MC
2803 multi-telescope files which can be produced with the coming
2804 camera version 0.7.
2805
2806 - added classes to read and interprete central control report files
2807 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2808
2809 - enhanced merpp (the executable) to support .raw and .rep files.
2810
2811 - added classes for light calibration (MCalibration* and
2812 MHCalibration*) by Markus Gaug. Further work has to be and will
2813 be done soon.
2814
2815 - Added a preliminary 'synchronizer' (MReadReports) which will
2816 replace MReadMarsFile as soon as it is finished.
2817
2818 - Added a tutorial macro demonstrating how report files are merpped
2819 and how they can be read from the root file in the correct order
2820 of time (readrep.C)
2821
2822 - Added a generalized histogram (similar to MH3) called MVsTime
2823 which allows to plot variables (or rules - MDataChain - of
2824 variables) vs time. For an example have a look at tempvstime.C.
2825
2826 - Changed the name of the event trees:
2827 + Events --> Events
2828 + PedEvents --> Pedestals
2829 + CalEvents --> Calibration
2830
2831 - changed name of MTime in the event trees from MRawEvtTime to MTime
2832
2833 - added displaying the sector indices to the mars event display
2834
2835 - Magic Online Analysis (MOnA) implemented in a first version
2836 (see mona.cc, MOnlineDump and MOnlineDisplay)
2837
2838 - added classes to calculate event rate
2839 (preliminary: MEventRateCalc, MEventRate)
2840
2841 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2842
2843 - added classes dealing with the telescope pointing position (MPointing*)
2844
2845 - implemented the 'final' Mars time stamp based on some experiences with
2846 the new 'Synchonizer'
2847
2848
2849
2850 *** Version 0.8.2 (2003/11/10)
2851
2852 - accelerated standard analysis by a factor of 6-8 ...
2853 + doing precalculations in MGeomCam for the pixel area ratio
2854 + creating a look up table for the single pixels in MCerPhotEvt
2855
2856 - added task to calculates weights in case you want to 'change'
2857 the energy spectrum of a monte carlo file
2858 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2859
2860 - added a new executable star which implements the
2861 star.C macro as precompiled executable. Currently a flexible
2862 setup is not possible, but a 'input card' setup will follow.
2863
2864 - Starting to implement Multi-Telescope-Support based on the
2865 upcomming camera version 0.7. The base for a general support
2866 is implemented and the star-functionality is proven to work.
2867
2868 - Replaced Event-Display in and Camera-Display in the Mars GUI
2869 executable by a more convinient display base on MStatusDisplay.
2870
2871 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2872
2873
2874
2875 *** Version 0.8.1 (2003/10/20)
2876
2877 - added signal subtraction for pure on data by means of fitting
2878 the background in the off region or by performing a combined
2879 signal/background fit. Provides necessary histograms for
2880 obtaining energy spectra and a light curve.
2881
2882 - added classes to perform and study the selection of the
2883 2nd Level Trigger on MC data (example in triglvl2.C macro)
2884
2885 - added pedestal calculation
2886
2887 - implemented "democratic cleaning" (tail cut value proportional
2888 to pixel area) according to Wolfgang's suggestion.
2889
2890 - added Sigmabar treatment (calculation and basic histogramming)
2891
2892 - added basic routines to apply padding
2893
2894 - added first implementation of MARS-based source visibility plotter
2895 (needs to be linked against slalib, preliminary version)
2896
2897 - enhanced functionality of data chains: random numbers, conversion
2898 functions and access to MHMatrix objects
2899
2900 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2901 numbers under certain circumstances (runs with 0 events included)
2902
2903 - fixed a bug in the general filter MF (didn't work on some systems
2904 at all)
2905
2906 - fixed a bug in chaining files, which caused the analysis to crash or
2907 ignore files
2908
2909 - implemented more geometry classes describing the parameters used
2910 to simulate the PMT camera
2911
2912 - added new Monte Carlo classes containing the setup of the different
2913 programs in the MC chain.
2914
2915 - added a (preliminary) general task to evaluate chi-square of a given
2916 parameter in an eventloop.
2917
2918 - first implementation of a container describing the observatory
2919 location (Long, Lat, etc)
2920
2921 - added Random Forest - method for g/h-separation
2922
2923 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2924 (this means, that it is compiling, but not yet fully tested)
2925
2926 - added a new status display which can show the present status
2927 of histograms while an eventloop is running (MStatusDisplay,
2928 an example can be found at status.C)
2929
2930 - reorganized directories:
2931 classes describing the image --> mimage
2932 classes containing Monte Carlo Histograms --> mhistmc
2933 classes for Random Forest method --> mranforest
2934
2935 - added (event-)weights to fill histograms
2936
2937 - colors in logging output to screen
2938
2939 - changes to the Image Parameter declaration:
2940 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2941 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2942 + MHillasExt now derives from MParContainer instead of MHillas
2943 --> Files written with the old definition are more or less unreadable
2944
2945 - reading of reflector files
2946
2947 - display data from reflector files in the camera
2948
2949 - implemented currents (and display them in the camera)
2950
2951 - logarithmic scale in camera
2952
2953 - added class to iterate through directory contents (MDirIter)
2954
2955
2956
2957 *** Version 0.8 (2002/11/18)
2958
2959 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2960
2961 - corrected 48(!) wrong entries in the Next Neighbor table of the
2962 Magic Camera (all in the inner part of the outer ring, mostly
2963 missing a single NN)
2964
2965 - Fixed a bug in the table describing the Next Neighbours of the
2966 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2967 have any neighbour)
2968
2969 - changed trigrate.C: now it calculates the pure NSB triggers from
2970 a camera file (generated with no showers), so there is no need
2971 to introduce them by hand in the BgR array (for more details
2972 please ask Abelardo)
2973
2974 - added MHHadronness (and MHadronness) as a general facility to evaluate
2975 the quality of a gamma-hadron seperation method
2976
2977 - changed MWriteAsciiFile to accept rules (MDataChain)
2978
2979 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2980 must be replaced by calles to MWriteAsciiFile::AddColumn and
2981 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2982 changed.
2983
2984 - Implemented generalized event-matrices (one row per event)
2985 (MHMatrix)
2986
2987 - implemented the one dimensional composite probabilities
2988 (MHCompProb, MCompProbCalc, comprob.C)
2989
2990 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2991 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2992
2993 - Added a camera display displaying the pixel numbers to the
2994 event display gui.
2995
2996 - Added Monte Carlo Informations to event display gui
2997
2998 - Changed the camera display to display the pixel numbering
2999
3000 - Added three buttons to the camera display to change the palette
3001
3002 - Added the number of used and core pixels after image cleaning
3003 to MHillas
3004
3005 - Changed the algorithm used in MHillas according to TDAS 02-03
3006
3007 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3008
3009 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3010
3011 - Added fCosDeltaAlpha to MHillasSrc
3012
3013 - The numbers of photons used to calculate fConc and fConc1 in
3014 MHillasExt are now scaled with the pixel size, so that one get
3015 a four times smaller value for the bigger pixels in the outer ring.
3016
3017 - added new task to smooth the camera contents (MCameraSmooth)
3018
3019 - added possibility to use interpolated pixel values for blind pixels
3020 instead of removing it completely from the analysis
3021
3022 - Implemented the possibility to save the whole eventloop with
3023 its setup to a file. This information can be read and from
3024 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3025 and MEvtLoop::MakeMacro. If you find something not working, please
3026 report - this stuff is still in a beta phase.
3027
3028 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3029 file having crab starfield, but also for all following files - fixed
3030
3031 - MTaskList::PrintStatistics can now be instructud to print also the
3032 title, too: use PrintStatistics(0, kTRUE)
3033
3034 - Changed the image cleaning so that pixels with to many 'used'
3035 neighbors are left used (to get rid of 'holes' in events)
3036
3037 - Introduced more output to the camera displays
3038
3039 - Added an array of histograms (eg one hist per run), MHArray
3040
3041 - Added a _preliminary_ version of the reader for CT1 PreProc files
3042 (MCT1ReadPreProc)
3043
3044 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3045 (thanks to Raquel)
3046
3047 - added the first energy estimator (MEnergyEstParam, estimate.C,
3048 estfit.C) using a parametrization
3049
3050 - Added some new Monte Carlo paremeter containers used to store
3051 setup information from the MC chain (MMcConfigRunHeader,
3052 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3053
3054
3055
3056 *** Version 0.7 (2002/04/30)
3057
3058 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3059 the pedestal mean value was saved incorrectly. For files from
3060 this versions we substract 0.5 from the pedestal mean.
3061 WARNING: This may effect your results, so don't wonder...
3062
3063 - First implementation of an algorithm using only triggered events
3064 for the collection area calculation
3065
3066 - Ascii Output can now also be used for parameter containers which
3067 doesn't overload MParCointainer::AsciiWrite
3068
3069 - The Ascii Output is now also capable of writing single data members
3070 of one container
3071
3072 - You are now able to change the order of the values written to the
3073 ascii file
3074
3075 - You can now specify a conversion factor for each data member written
3076 to an ascii file. This may be usefull to change the units of the
3077 data member (eg. degrees instead of millimeters in case of the
3078 hillas parameters)
3079
3080 - Replaced old MHillas by a new structure which allows you to extend
3081 the parameters stored in MHillas very easily:
3082 see MHillas and MHillasExt
3083
3084 - Added classes to handle source dependancy of image parameters:
3085 see MHillasSrc
3086
3087 - Added container (MBinning) to have a standard input for the binning
3088 in different histograms (eg. the Energy bins should be the same in
3089 all histograms)
3090
3091 - Changed Hillas histograms from mm to deg
3092
3093 - Added the flexible binning to the hillas histograms
3094
3095 - Added a filter for the alpha parameter (MFAlpha)
3096
3097 - It is now possible to write single data members of a class object to
3098 an output stream instead of the whole container only
3099
3100 - Added a generalized filter for a data member:
3101 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3102
3103 - Added a generalized Filter parser for more difficult filter rules
3104 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3105
3106 - Added new Monte Carlo histograms:
3107 MHMcEnergyImpact and MHMcEfficiency
3108
3109 - Added many new histograms needed for the flux calculation.
3110
3111 - Added a generalized histograms which can fill and show up to three
3112 data members in either a one-, two- or three-dimensional histogram, eg:
3113 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3114
3115 - Added:
3116 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3117 * calculation of <Theta> as a function of time (MHThetabarTime)
3118 they are needed in the flux calculation in
3119 order to select for a given bin in Theta (or time) the appropriate
3120 effective collection area, which is assumed to be given as a function
3121 of Theta and the true energy
3122
3123 - Added calculation of the migration matrix in the energy
3124 (MHMcEnergyMigration):
3125 the migration matrix describes the migration from the true (E_true)
3126 to the estimated energy (E_est); it is needed to determine the
3127 distribution of E_true from the measured distribution of E_est
3128 by unfolding
3129
3130 - changed the color palette in the camera display to DeapSea.
3131
3132
3133
3134 *** Version 0.6 (2002/01/15)
3135
3136 - Introduce the option of disable pixels (MBlindPixels and
3137 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3138 able to deal with Star Field NSB.
3139
3140 - Fixed a bug in the pedestals substraction
3141
3142 - Introduced verbosity levels
3143
3144 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3145
3146 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3147 work correctly (thanks to Abelardo)
3148
3149 - Introduced correct treatment of the diffuse Night Sky Background
3150 and NSB (MMcPedestalNSB)
3151
3152 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3153
3154 - Introduced MMcRunHeaders which contains monte carlo run informations
3155
3156 - Added a 'Print'-Task (MPrint) which calls the Print function
3157 of a parameter container for each event
3158
3159 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3160
3161 - changes to be more efficient with root 3.02/06
3162
3163 - root 3.02/06 fixes:
3164 + the memory leak when reading MRawEvtData
3165 + loosing more time than necessary to update the progress bar
3166
3167 - MWriteAsciiFile is now capable of writing more than one container
3168 in a line. For example: To be able to write Monte Carlo and
3169 Hillas values (energy and alpha) in one line.
3170
3171
3172
3173 *** Version 0.5 (2001/11/06)
3174
3175 - Added new GUI functionality (Analysis)
3176
3177 - Added a camera display to be able to display events in the camera
3178 together with the calculated hillas ellipse
3179
3180 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3181 object at any state of the analysis, so that the output are several
3182 states
3183
3184 - Fixed a bug in the collection area error calculation
3185 (Thanks to Ciro and Abelardo)
3186
3187 - Fixed a bug which causes merpp to crash in some environments
3188
3189 - Implemented auto enabling scheme for Branches to speed up reading
3190 a lot (see MReadTree and MTask)
3191
3192 - Fixed a bug in the Histogram classes which caused histograms to
3193 be written to a file by MWriteRootFile without request
3194
3195 - changed the object I/O from the old stylish root I/O to the new
3196 'auto evolution scheme' This was done only for classes which are not
3197 yet used in Monte Carlo files, so that these files are still readable.
3198
3199 - Added support for a progress bar in MEvtLoop and MReadTree
3200 (see the Analysis Window in Mars for an example)
3201
3202 - Fixed a bug in the package creation which disturbed the conversion
3203 between a mars version unpacked from a tar file and the repository.
3204
3205 - Changed the code to writer merpped (converted into root format)
3206 raw files, to get faster (around 10%)
3207
3208
3209
3210 *** Version 0.4 (2001/09/20)
3211
3212 - This release is made to compile on a root version >= 3.00
3213
3214 - Fixed a bug which causes MReadTree to read the first file only
3215
3216 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3217
3218 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3219
3220 - Added a task to write several container to a root file (MWriteRootFile)
3221
3222 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3223
3224 - Added calculation of the collection area (MMcCollectionAreaCalc)
3225
3226 - fixed some bugs in the Hillas calculation
3227
3228 - added filters to be able to control the task execution dependent on
3229 a parameter (for example: the number of level 1 triggers in a MC-file)
3230
3231
3232
3233 *** Version 0.3 (2001/04/23)
3234
3235 - Many demo macros added
3236
3237 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3238
3239 - Hillas Calculation added
3240
3241 - Standard image cleaning available
3242
3243 - MReadTree is now able to handle more than one file
3244 (Remark: of the same structure)
3245
3246 - Now we are able to display events in a first version of the
3247 Camera event display. To do this we must run the macro
3248 "macros/readCT1.C" to read data from CT1.
3249
3250
3251
3252 *** Version 0.2 (2001/01/24)
3253
3254 - First Implementation of a Gui to read the raw data. Start the
3255 gui with the command mars.
3256
3257
3258
3259 *** Version 0.1 (2000/12/20)
3260
3261 - First official release 0.1
3262
3263 - Changes:
3264
3265 + changed calling style of MRawPixelIterator from do...while to
3266 while-loop
Note: See TracBrowser for help on using the repository browser.