1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 ;showplot:
11
12 * If a file without a MStatusArray is opened all object (not just
13 canvases) found in the file are drawn. Note that this may result
14 in empty tabs.
15
16 ;ceres:
17
18 * The night sky noise is now scaled with the sensitive area and
19 is given in units per square centimeter
20
21 * Added the possibility to add a cut after the image parameter
22 calculation (''Cut'')
23
24 * updated the PDE of the GAPDs with a more reliable curve from
25 the meeting page (linear extrapolate below 350nm)
26
27 * The impact distribution in the event distrbutions is now
28 perpendicular to Alt/Az and the histogram is displayed in 1D
29
30 * The GAPD PDE has been updated
31
32 * PDEs and mirror reflectivities have been linearily extrapolated
33 to match the wavelegth range between 290nm and 900nm
34
35 * There is no default pulse shape anymoe it must be given in
36 the resource file
37
38 ;callisto:
39
40 * Fixed a bug which prevented MAGIC Monte Carlo file from being
41 calibrated (ceres files worked)
42
43 ;ganymed:
44
45 * added new starguider calibration for sequences since 1000534
46
47
48
49== Version 2.3 (2009/03/07) ==
50
51 ;SUGGESTION
52
53 * There is no need to re-run any data because no change took place which
54 could have an effect on the output. However, if you want a
55 meaningful SrcPos plot for your MCs in sponde you must re-process
56 star for your MCs first.
57
58 ;REMARK
59
60 * File produced with this release containing a camera geometry (which
61 are basically all files were produced as default) will not be readable
62 by older releases.
63
64 ;general
65
66 * fixed a few small bugs which could cause the display to crash in ganymed
67 and sponde
68
69 * in sequence file the date can now be omittet. In this case the
70 leading date with the underscore is missing in the expected filename
71
72 * the geometry class now also supports other geometries than just hexagons
73
74 ;automation
75
76 * added magnetic field Azimuth direction (ARRANG), currently
77 at ~ -7deg at La Palma
78
79 ;database
80
81 * plotdb.php: added default (sequences) for startup, added possibility
82 to set size of plot
83
84 * added a new table ''RunDataCheck'' which containes the rates after
85 image cleaning for every run which succeeded star. It can be
86 plotted using ''plotrundb.C''
87
88 ;merpp
89
90 * added support for Arehucas Version >= 200812140
91
92 * added support for Arehucas Version >= 200809030
93
94 ;mars
95
96 * The display now also displays the trigger pattern
97
98 * The display can now display ceres reflector (_R_) files
99
100 ;ceres
101
102 * added a uniformly distributed one-bin time jitter for the start of the
103 digitization. Otherwise the first photon would be digitized always with
104 the same alignment to the bins
105
106 * Added a plot showing the production height of the photons
107
108 * Moved the particle id from the event header to the run header
109
110 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
111
112 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
113
114 * Added many new options to control the tasks. For deatils see ''ceres.rc''
115
116 * Removed obsolete plots in pedestal and calibration mode
117
118 * Removed the non-NightSky photons from the plots where they are just
119 disturbing
120
121 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
122
123 * The daq event number now represents the readout number
124
125 * The camera ''electronics'' can now be ''switched off''
126
127 * A new tab ''Info'' now display basic things like the reflector
128 layout
129
130 * Improved reading speed for corsika files
131
132 * Improved memory handling (if a large ampount of memory was needed
133 for a single event all further events were stored in the same
134 memory and it was never freed, so the program took this memory
135 until the end)
136
137 * Converted the code from MMCS' reflector program to MSimAtmosphere
138 (instead of the tables build in for MAGIC Winter and Summer
139 atmosphere we use the values written by Corsika fitted to the
140 tabulated atmosphere given as input)
141
142 * For caluclating the displayed image parameters in ceres a basic
143 image cleaning removing isolated pixels is now done.
144
145 * The magnetic field direction (ARRANG) is now taken into account
146
147 * Added plot for the energy threshold after trigger ''Threshold''
148
149 * Added plot for the effective collection area after trigger ''TrigArea''
150
151 ;star
152
153 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
154
155 * The definition of fConcCore has slightly changed. The numbers
156 might decrease a little bit (the effect should be rather small)
157
158 ;ganymed
159
160 * added pointing model 328198
161
162 ;sponde
163
164 * The SrcPos plot for your MCs was so far meaningless because it just
165 displayes the MSrcPosCam data from the input star-files. Unfortunately,
166 this containes was never written to the star-files yet.
167
168 * A new Tab 'OnTime' is available which is an effective on-time
169 fit as in star but for all data. This is mainly for manual cross-check
170 of the effective on-time
171
172 * In some circumstances it might be necessary to re-calculate the
173 eff. on-time from the fit in the new tab, e.g. when a zenith distance
174 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
175
176 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
177 it to its own output file (for convinience)
178
179
180
181== Version 2.2 (2009/01/30) ==
182
183 ;SUGGESTION
184
185 * This release doesn't contain a major change which is expected to
186 change your results. Nevertheless there are small changes to
187 the calibration which can effect at least the first few hundred
188 events in any (mainly MUX and even more SUM) sequence a little bit.
189 So it is recommended although not necessary to reset your sequences
190 in the database before further processing.
191
192 ;NEW
193
194 * A first implementation of a Monte Carlo simulation program
195 (ceres - Camera Electronics and REflector Simulation) has been
196 implemented. It can simulate a full telescope already including
197 a complete reflector simulation and a flexible trigger and readout
198 simulation. Currently, no perfect setup is implemented and
199 especially the output of the program (data structure) should
200 be considered alpha state. Also the user interface is not yet
201 ready.
202
203 ;general
204
205 * All command line options after -- are now interpreted as
206 arguments (usually everything which doesn't start with a minus)
207 rather than options (usually everything which starts with a
208 minus). This allows to use file names starting with a -
209
210 * In all resource files you can now initialize the random number
211 generator. For details see: MJob::InitRandomNumberGenerator
212
213 * added a new program called ''readcorsika''. It's purpose is (in analogy
214 to readraw and readdaq) to read a Corsika output file (for now
215 only cherenkov output is supported) and print its contents in a
216 human readable form. It can also write the contents of this file
217 into a root-file.
218
219 * The calculation of the maximum distance to the origin in a MGeomCam
220 has been improved (edges might be further away than the sides).
221 This is just a tiny change but it might change the appearance of
222 the radial profiles a little bit.
223
224 * The default binning of the center-of-gravity plot has slightly been
225 increased
226
227 ;Database
228
229 * Added informations about the DC currents (fMinCurrents, fMedCurrents
230 and fMaxCurrents). The values are retrieved from the plots showing
231 the average DC currents of all pixels versus time.
232
233 * Websites with tables have now the opportunity to remove lines
234 ('-' button at beginning of each line) and get all lines back
235 ('+' at top of the column)
236
237 * Websites: added option to query only sequences containing sumtrigger
238 events
239
240 * Websites: added option to group by date (year, month, night) for runs
241 and sequences and enabled that combining of different group-bys,
242 e.g. status, date and source is possible
243
244 ;automatic analyis
245
246 * Rewritten producing plots in the web.
247 New plots, namely the output of plotoptical.C (extinction curve from
248 KVA), plotstat.C (status of the automatic analysis (percentage of
249 processed, analysed data etc.)) and plotusage.C (statistics of the
250 condor usage in the data center) has been are available now next to the
251 plots of plotdb.C
252 Mean values from the plots (output of the macro) are provided in a
253 txt file now.
254 The creation of the plots for callisto, star and ganymed in the web is
255 now steered via database. Consequently the plots are faster and
256 reliable up-to-date.
257 For all plots, a new layout is available facilitating the browsing
258 through the plots and providing additional information on the
259 displayed values. (tabs.php) These plots are linked from the DB
260 websites and the wiki.
261
262 ;statusdisplay
263
264 * The ''Loop'' entry in the menu bar now contains an option to pause
265 the loop and to process single events.
266
267 ;merpp
268
269 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
270 instead of RunHeaders)
271
272 * Now allows to merpp files newer than 2008/09/03.
273
274 * Added fixes for wrong (wrong or double) run- and file-numbers
275 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
276
277 ;callisto
278
279 * Extracting the pulse position for the pulse position check events
280 with sum trigger were denied. This decreased the statistics
281 extremely and therefor the resulting puse position was calculated
282 quite weak. Now sum events pass the calculation if and only if they
283 have also a level 1 trigger.
284
285 * the extraction of pedestal events and pulse position from the
286 first data events is now more automatic and makes sure that
287 a more precise number of events is extracted independent of
288 the ratio with which pedestal events or events with signals
289 are contained in the data.
290
291 * Updated Muon calibration constants for all MUX data (teh changes were
292 all smaller than 5%)
293
294 ;star
295
296 * For the calculation of the effective on time all sum-triggered events
297 were skipped. Now all Level1-triggeres events will pass. This might
298 result in a slight inaccuracy of the effective on time.
299
300 ;ganymed
301
302 * If the source position is more than 1deg away from the camera
303 center an error is raised now.
304
305 * Hopefully fixed the bug ''ganymed crashes when resized''
306
307 ;sponde
308
309 * Fixed a problem which causes the fitted spectral slope to be displayed
310 incorrectly. If you use MJSpectrum::FormFlux in your macros make
311 sure that the parameter 0 of your fit is negative.
312
313 * Added a histogram showing the read source position of your MCs
314
315
316
317== Version 2.1.1 (2008/08/04) ==
318
319 ;Database
320
321 * Added the median number of photo electrons from the calibration
322 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
323 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
324
325 * Added fTotOnTime, which is the on-time as given by the run-headers
326 (in contradiction to fAbsOnTime which comes from CC)
327
328 * Added new primaries for the new data structure (Magic II): for the
329 tables dealing with sequences (SequenceBuild Status, Sequences,
330 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
331 this is the telescope number (fTelescopeNumber) for the tables dealing
332 with runs (RunData and RunProcessStatus) this is in addition the file
333 number (fFileNumber)
334
335 * Added column fPriority to the status tables to be able to steer the order
336 in which the data is processed. As default the run, sequence and dataset
337 number are used.
338
339 ;automatic analyis
340
341 * Adapted scripts to the new data structure: They can handle now different
342 telescopes (getting the information as usual from the database).
343 The paths for Magic 2 are not yet implemented.
344
345 ;general
346
347 * should work now with root 5.20/00 (please note that root 5.20/00
348 we encounter crahses in the status display which are ot yet
349 understood)
350
351 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
352 instead of the base name of the file. This makes them easier to
353 access from the code
354
355 * Default Monte Carlo names in MSequence do not require the _E at
356 the end anymore
357
358 * where abrrevating a sequence file with a sequence number is possible
359 also "telescope:sequence" is now accepted, e.g.:
360 star 2:2000123 --out=output
361 see the programs' help for more details.
362
363 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
364 from the database. See the constructors for more details.
365
366 * MReadTree now supports friends
367
368 * MReadTree can now read also files not written by MARS and store
369 the data encapsulated in emulated MParContainers
370
371 * added a new starguider calibration valid since 15.1.08
372
373 ;showplot
374
375 * showplot can now read more than one file at once. This is especially
376 inetersting if reading files containing pure canvases
377
378 ;merpp
379
380 * we merpp the dc currents now also from the camera reports (they have
381 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
382
383 * In the automatic analysis we omit merpping of the currents from the
384 caco files and use the lower rate camera reports from the cc files
385 instead
386
387 * merpp has been redisigned to allow merpping of the cc-reports
388 of a whole sequence. This allows to design a very simple analysis:
389 mkdir output
390 ./callisto 100776 --out=output
391 ./merpp 100776 output
392 ./star 100776 --ind=output --out=output
393 Instead of the sequence number also sequence files are accepted.
394
395 * Implemented a fix for run-numbers between 1001348 and 1001396
396 which were incorrectly assigned by the cc.
397
398
399 ;callisto
400
401 * added a filter again which was was removed in the last release.
402 it removed the most brightest events. This should not change
403 any analysis result because these events are so bright that
404 they cannot be analysed anyway, but the bad-pixel plots doesn't
405 show outliers.
406
407 * updated muon calibration constants for the periods 51-57,
408 58-63 and 67-
409
410 ;star
411
412 * The camera currents are now displayed with the rate of the camera
413 reports instead of the caco reports
414
415 ;ganymed
416
417 * if mc camera files are new enough (>=8) the source position in the
418 camera is now calculated from the stored telscope and shower
419 orientation (Note, that this might not be suitable in all cases
420 depending on the aim of the study. These case still needs
421 implementation)
422
423
424
425== Version 2.1 (2008/06/18) ==
426
427 ;Database
428
429 * introduced average temperature and wind speed from star-files
430
431 * introduced average values from Pyrometer (mainly Cloudiness)
432
433 * introduced the ratio of accepted calibration events in the
434 calibration run
435
436 * introduced the average rates of the different trigger pattern,
437 e.g. the rate of pedestal and calibration events, from the signal-file
438
439 ;general
440
441 * fixed GroupBy options in plot*.C macros
442
443 * only display KVA points (not the Tuorla points) in plotoptical.C
444
445 * all programs now allow to add resources to the ones from the resource
446 file or overwrite them from the command line. This can be done like this
447 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
448 if something seems to be wrong you can debug what the program is doing
449 using the option --debug-env=3
450
451 * increased the diversity of debug levels. That also means that with -v3
452 you get now less output, i.e. only the output which is important for
453 an analysis. To get more output which helps for debugging try 4, 5 and 6.
454
455 * fixed a problem in the task synchronizing the reading of the reports
456 and the data stream. The effect was that in some circumstances the last
457 events of some trees could have been skipped. Since this is only a
458 very tiny part of the data no severe effect to your analysis results
459 is expected (an exception might be very short, i.e. singel runs,
460 datasets).
461
462 * Dataset file now allow to include the sequence file directly within
463 the dataset file and also allow to exclude single runs from the dataset.
464 (for more details see Class reference of MDataSet)
465
466 * Sequence files now allow for excluding runs from the analysis
467 (for more details see Class reference of MSequence)
468
469 * added code to process the sum-trigger flag
470
471 * the histogram classes MH3 and MHn now support profile histograms
472
473 * the histogram classes MH3 and MHn now support labels at the axis
474
475 * the Random Forest Train-classes (MJTRain*) now store the used datasets
476 in the output file
477
478 * the MFMagicCuts have a new option to allow a linear area cut (for
479 special studies)
480
481 * The liniking of the shared object is now done into a file defined
482 by 'mktemp'. This should be a local file system which accelerates
483 liniking a lot.
484
485 * The code has been prepared for compilation with root 5.18/00d
486
487 * The MHEnergyEst histogram now shows the distribution of
488 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
489 and (Eest-Emc)/Emc vs Emc.
490
491 * fixed mars (event display) for merpped raw-data and MC data
492
493 * adapted the synatx of sequence files to allow for the new run/file
494 scheme. For more details see class description of MSequence
495
496 ;showplot
497
498 * Added support for tiff files
499
500 * Added support for csv files (tables containing tab number,
501 name and title)
502
503 * Tabs now can have a title which is displayed in the postscript file
504
505 * When multiple file are written at once (e.g. pngs from a display)
506 it is now possible to use the tab name and or tab number in the
507 file name. For details see showplos's help.
508
509 ;merpp
510
511 * Implemented cc file version 2008-02-20/0
512
513 * Implemented cc file version 2008-05-19/0
514
515 * With new options merpping can be restricted (in addition to the
516 run-number) also by telescope and file number.
517 For details see "merpp --help"
518
519 * Implemented raw data format 11 (the most important change, except
520 from plenty of changes in the format definition, is the addition
521 of the file-number in the header) If nobody makes a mistake this
522 format should have the advantage that it is by definition forward
523 compatible, so old programs will be able to read newer formats.
524
525 * Added Pyrometer information to default output (stored in a new Tree
526 Pyrometer, needs a complete new merpp, i.e. new calibration)
527
528 * Merpping (also update) can now be restricted to one single report.
529 For example:
530 If you want to update an old file with Pyrometer information call
531 merpp --only=Pyrometer --update
532
533 ;callisto
534
535 * in the pedestal processing now at least 50 processed events are
536 required for succeeding.
537
538 * the signal and calib files now contain also the sequence information
539
540 * the two MPedestalCam in the calib file now have proper names
541 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
542
543 * Both pedestal cams now contain the number of events processed
544
545 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
546 i.e. for the extraction of the calibration pulses basically the average
547 over all events of the first slice instead of all slices was used.
548 Since pedestal and calibration constants are continously recalculated
549 this only effected the very first events of every sequence.
550
551 * For the extraction of the position of the maximum sample now the
552 extraction range is set automatically to the extraction window,
553 before the whole accessible range was used.
554
555 * If the number of samples in the events and the number of samples
556 in the run-header disagrees now an error is raised (this can
557 happen in not well simulated Monte Carlo files)
558
559 * In the case of MUX-data pedestal events with the lvl1 trigger flag
560 could survive into the pedestal calculation -- fixed.
561
562 * Tab "TrigPat" added showing the distribution of the trigger pattern
563 as found in the run-files (normalized with the run length)
564
565 * The selection of events from the trigger pattern has been improved.
566 If the trigger pattern is corrupted events won't pass anymore.
567
568 * Added a new command line option --dev-null to suppress output of
569 Y-files (this is useful for test cases)
570
571 * added a new tab "CalPos" showing the arrival time of extracted
572 interleaved calibration events
573
574 ;star
575
576 * the star file now contains also the sequence information
577
578 * Added a new command line option --dev-null to suppress output of
579 I-files (this is useful for test cases)
580
581 * Tab "Rate" added showing the distribution of the trigger pattern
582 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
583 the Y-files (normalized with the run length)
584
585 * The effective on-time calculation doesn't use events with only
586 sum-trigger anymore
587
588 * The data in the MHWeather tab has been reorganized. The never
589 working solar radiation has been removed and the data from
590 the pyrometer (cloudiness, air and sky temperature) is
591 displayed in addition.
592
593 ;ganymed/sponde
594
595 * Now data points are even shown correctly if they have error bars larger
596 than one sigma. Points with null or negative significances are omitted.
597
598 * DrawNicePlot now allows to set a projection range
599
600 * Updates pointing models. One is applied after the implementation
601 of the new LUTS in August, the other one is applied after the
602 next major change of the pointing model in October. Note that
603 these models are preliminary and give wrong results below Zd=65deg
604
605 ;sponde
606
607 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
608
609 * a new option "--force-runtime" is available. In case of very short
610 datasets (for light-curves) which are in the order of a few
611 minutes the calculated effective on-time is not very acurate because
612 it is quantizised in the order of a minute. Therefore you can switch
613 to using the real run-time instead (remakrt: this ignores any
614 dead-time!)
615
616 * a more analytical way is used to "fill" Monte Carlos into regions
617 of impact parameters which have not been simulated because the
618 trigger efficiency is assumed to be 0.
619
620 * estimated sensitivity curves for hi and lo zenith angles are shown
621 scaled to the correct observation time and collection area
622
623 * the Monte Carlo events after cuts are now written to the output file
624 if an output file given
625
626
627
628 *** Version 2.0 (2007/09/03)
629
630 - database: the position used for the pulse pos check was missing
631 in the callisto output and could thus not be filled into the DB.
632 Also the old values seemed not exactly the PulsePos used for
633 teh check.
634
635 - general: Resource file now allow an Include-Resource, i.e. you can
636 read a resource file with default settings, include it in your
637 resource file and overwrite the settings in your file. More than
638 one include file is allowed. Inclusions can be iterative.
639 Include: mydefaults.rc yourdefaults.rc
640 The resources in the first file have higher priority than the
641 second file.
642
643 - general: Now the output files (calib*.root, etc) also contain the
644 resource file (to check it open it in the TBrowser and choose Print()
645 from the context menu)
646
647 - general: Dataset files now allow to overwrite the default path
648 to search for sequence and data files. Note, that the program
649 option and individual resources will overwrite it. For example:
650 SequencePath: /magic/montecarlo/sequences
651 DataPath: /magic/montecarlo/star
652
653 - general: Fixed a problem with variables in MDataPhrase. It seems
654 that only optimdisp (didn't work) was effected.
655
656 - general: Some improvements to the optim and train processing. For
657 example the ststud window now got a proper title.
658
659 - general: The "Status Display: " was removed from the window title
660 within an Eventloop.
661
662 - general: added a new flexible histogram-class (MHn) which can be used
663 for example in testing after optimizations or training to produce
664 user defined histograms.
665
666 - general: The Random Forest now allows attaching an evaluation
667 function which is applied to its output. This allows to train
668 on whatever you like (eg. train on log10(energy), but return
669 energy)
670
671 - general: The Random Forest training of energy (trainenergy.c) and
672 disp (traindisp.C) has been improved by more graphical output to
673 judge the result.
674
675 - general: The training of energy (trainenergy.C) has been improved
676 a lot by training on a different quantity than energy. It gives
677 a result which is highly independant of the source spectrum
678 and shows lower bias than all other options.
679
680 - general: Dataset files are allowed to contain collections of
681 datasets. For more details see the class reference of MDataSet.
682
683 - general: The default WobbleMode in a datset file now (if not
684 overwritten) is "auto", i.e. wobble mode is set if the dataset
685 doesn't contain off-sequences.
686
687 - merpp: Merpp can read file format version 9 now. Please realize
688 that for file format version 9 the extraction range is different
689 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
690 the first and last 15 slices have been removed from all MUX data.
691
692 - mars: Similar to writing movies you can now select events which
693 should be displayed in your display. Therefore add the following
694 lines to your mars.rc:
695 MFEvtNumber.FileName: ganymed00223552.root
696 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
697 The input file can be a ganymed-file after (ganymed*.root) or
698 before (ganymed*-summary.root) file. For example to select all events
699 from your on sample after cuts (excluding the ThetaSq cut) use
700 MFEvtNumber.Selector: DataType.fVal>0.5
701 To show all events from your on-sample after quality cuts
702 use the summary file instead.
703
704 - mars: new ways to call mars are implemented. Instead
705 of calling
706 mars filename.root
707 you can now also use
708 mars sequence.txt
709 or
710 mars sequence.txt inputpath
711 or replace sequence.txt by the sequence number if the default
712 sequence file should be used.
713
714 - mars: The default size has been increased
715
716 - mars: There are two new heckboxes which allow to switch off
717 the calculated image parameters
718
719 - callisto: was broken for MCs... fixed.
720
721 - callisto: improved calculation of spline coefficients a lot. This
722 leads to a further improvement of the event rate calibrating MUX
723 data of about 15% (175evt/s instead of 150evt/s)
724
725 - callisto: finally the raw data we read is now real 16bit (with
726 10bit precision) for MUX data and not a stripped 8bit number
727 anymore. Due to scaling of the numbers (without precision loss
728 into an [0-256[ range, the final numbers for pedestal, pedestalrms
729 and extacted signal don't change. However, at all places where
730 raw data is directly accessed (eg. saturation and variation
731 limits in the signal- and pedestal-extraction) the numbers
732 refer still to the data's 16bit range.
733
734 - callisto: The maximum arrival time difference used in the bad
735 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
736 for both, old FADC and MUX-FADC, data.
737
738 - callisto: Be aware that callisto is now calibrating the arrival time
739 in nanoseconds rather than time slices. Also all following tasks
740 have been changed to assume ns units now. If you star data
741 calibrated with an older version it might be necessary to adapt
742 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
743 to obtain optimal results. The plot in the PulsePos tab
744 will now be in ns, too. This might also mean that the Muon
745 analysis in star might not work as perfect as expected as long
746 as old files read in.
747
748 - callisto: The calibration constants of earlier updates got lost
749 somehow. All constants have been updated.
750
751 - star: The PSF is now determined from the profile of the ArcWidth
752 instead of arcwidth/radius. The old way gave to much weight
753 to the bins with low statistics. The reference lines have been
754 updated.
755
756 - star: For speed reasons events suitable for the muon analysis
757 are now also preselected by fConcCOG<0.1 which seems to be a very
758 good preselector for muons.
759
760 - star: is now calculating a new timing parameter the Slope along
761 the major and minor axis of the shower. Therefore a numerical
762 solution of a line-fit is used. To use MHillasExt.fSlopeLong
763 and MHillasExt.fSlopeTrans don't forget to multiply it with
764 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
765
766 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
767 have been removed from MNewImagePar. They have never been good for
768 anything.
769
770 - star: Implemented a new recursive algorithm which is supposed to be
771 faster. Also implemented new cleaning oiptions, which are:
772 + CleanLevel0:
773 The cleaning level above single core pixels can be kept
774 + KeepIsolatedPixels:
775 Define whether single core pixels should be kept
776 + TimeLevel1:
777 The coincidence window in nanoseconds to single used neighbors
778 + TimeLevel2:
779 The coincidence window in nanoseconds to two used neighbors
780 + PostCleanType:
781 MOde in which a time dependent post cleaning should be applied
782 0: No post cleaning
783 1: Require for each used pixels at least one used neighbor
784 within a time-window of CleanLevel1
785 2: Require for each used pixels at least two used neighbor
786 within a time-window of CleanLevel2
787 3: Require first two and second one used neighbor
788 within a time-window of CleanLevel1 and fCleanLevel2
789 respectively
790 + RecoverIsolatedPixels:
791 - recoveres isolated core pixels if they have a used neighbor
792
793 - mars/star: The new default cleaning is:
794 + CleanLevel1: 6.0
795 + CleanLevel2: 3.0
796 + CleanTime1: 1.75
797 + CleanTime2: 1.75
798 + PostCleanType: 3
799
800 - star/ganymed: The old spark-cuts have been replaced by new ones.
801 These new spark cuts have been cross checked with the sequences
802 84720 (before splitter), 101041 (after splitter) and 223539 (new
803 FADCs). In all cases they seperate pretty well, but of course not
804 perfect. Monte Carlos have suggested to tighten the cuts a little
805 bit further at low sizes. This has been done.
806
807 - ganymed: IMPORTANT - The spark cuts have been changed to match
808 all available data more or less well. This might mean that for
809 YOUR data there are still sparks visible.
810 Whenever you do an analysis you have to make sure that NO sparks
811 survive your cuts!
812
813 - ganymed: The old hadronness and size cuts have gotten new indices
814 (10, 11). The old indices 8 and 9 now mean an additional condition
815 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
816 If you want to switch off this cut just move the line far away enough,
817 e.g. by setting c[9] to -500. Please update your ganymed.rc files
818 accordingly!
819 The unit of c[9] is deg. It is the dist at which your cut will
820 cross the slope==0. The unit of the slope is ns/deg. So if
821 you readin files calibrated with an older Mars-version you
822 have to adapt the default value for c[9] to the FADCs:
823 - Multiply by two for the MUX FADCs (run number > 200.000)
824 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
825 - Multiply by 42 for the meaning of life (run number = 200.000)
826
827 - ganymed: The old Cut0 is now called CutQ and is calculated before
828 the source position is caluclated. If you need a quality cut
829 including source dependant data (be very carefull with this!)
830 you have to use Cut0 instead.
831
832 - ganymed: now properly supports three off regions in wobble mode.
833 It will be the default from now on in ganymed_wobble.rc. To change
834 the number of off-regions use
835 NumOffSourcePositions: 1
836 in your ganymed.rc. Also by default no off-theta cut will be done
837 anymore so that you will get a background level higher than the
838 signal level in your ThetaSq plot for ThetaSq>0.2.
839 Due to this be carefull changing the scaling mode away from
840 "None". You will underestimate your signal if your scale interval
841 is not properly set.
842 (Rem: ThetaSqN is no longer needed)
843
844 - ganymed: is now storing the events of all (on- and off-)
845 source positions even in the case of more than one off-source
846 position. This should allow sponde to work properly and the
847 energy estimation is done correctly in all cases (without any
848 "nearest position" trick)
849
850 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
851 with a real pointing model for the starguider is done, calibrated
852 with more than thousand tpoints taken from this date on.
853
854 - ganymed: was broken for Wobble-MCs... fixed.
855
856 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
857 has changed. Note that your old ganymed.rc will be incompatible
858 with the new algorithms! Please check the ganymed.rc files and
859 the class description of MFMagicCuts for more information.
860 It is recommended at the moment to use identical Disp-Parametrizations
861 for on/off- and wobble-mode. If cuts are optimized only
862 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
863 should be optimized. All other values should be kept as they are.
864 If you want to do an anylsis without timing a parameters, you can
865 switch off the timing cuts by seeting parameter 7 to a very small
866 value (eg. -99). To remove the slope parameter from the disp
867 paremtrization set parameter 8 to 0.
868
869 - ganymed: The distribution of observation time versus zenith
870 angle is now shown for off- AND on-data.
871
872 - ganymed: The contents of the source position plot are no longer
873 averaged, thus a lot of (fake) events between the two wobble
874 positions have disappeared.
875
876 - ganymed: There is a new tab "CutT" it contains the VsSize plots
877 with the CutT, whihc is defined in ganymed.rc, applied. It
878 is resonable to use your theta-cut for it, to see if there is
879 something strange (sparks!) in your signal-region.
880
881 - ganymed: To choose a dataset from a collection in a dataset file
882 use the new command line option "--dataset=12345"
883
884 - optim, sponde: should now properly support three off-regions.
885 Just produce your ganymed summary files with three off-regions.
886 optim and sponde will automatically get all off events from
887 all off-regions from this file. Please do not forget to
888 set the scaling in optimwobble.C properly:
889 fit.SetScaleUser(1./3);
890 it is not yet read in automatically (will follow soon).
891 In the case of fixed Scale you can also use
892 cuts.SetThetaCut(MFMagicCuts::kOn);
893 no off-cut needed.
894 Be carefull in case of three off-regions when switching on
895 scale mode. Make sure that the scale interval is set correctly.
896
897 - sponde: sponde.rc and sponde_onoff.rc are now idetical
898
899 - sponde: the resouce files have been rewritten with a lot of
900 comments and a well working parametrization for an energy estimator
901
902 - sponde: In the estimated energy versus monte carlo energy plot the
903 contents where exchanged.... fixed.
904
905 - sponde: the so called "accurate"-mode has been removed. It didn't
906 give any improvement in accuracy, only decreased execution speed.
907
908 - sponde: the so called "simple"-mode has been removed. It didn't
909 give any improvement in simple.
910
911 - sponde: the so called "refill"-mode has been removed. It was anyhow
912 not implemented.
913
914 - sponde: now checks whether the theta distribution of your on-data
915 and the theta-distribution of your Monte Carlo sample (after
916 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
917 sample is incomplete) execution is stopped. Execution can be forced
918 using the new option --force-theta. Use this option with care!
919
920 - sponde: Proper collection areas can now be constructed also from
921 Monte Carlo samples generated with different maximum impact
922 parameters. Note that in previous version you neither got
923 a warning or failure, nor was there any obvious sign that the
924 collection area was overestimated due to usage of files with
925 different maximum impact parameters.
926
927 - sponde: If MC files with different lower energy limits are used
928 the primary MC spectrum is artificially completed down to the
929 lowest energy used at all. WARNING: that this gives correct
930 collection areas ONLY if none of the events in this region would
931 survive your cuts at all.
932
933 - sponde: the output file now contains more information about
934 the spectrum (eg. the full 2D collection area histogram).
935 Note, that this information can only be written to the file
936 if it is stored automatically via command line argument.
937 If you only store the status display from within the display
938 the information is lost.
939
940 - sponde: added a new tab "Disp". It shows the residual of the disp
941 (Disp-Dist) versus several parameters and it is meant to judge the
942 quality of the disp estimator. In the ideal case the residual is zero
943 and doesn't depend on any variable. The tab is displayed after
944 CutQ and Cut0.
945
946 - sponde: added a new tab "Energy". It shows the residual of the
947 energy (lg(estimated energy)-lg(monte carlo energy)) versus
948 several parameters and it is meant to judge the quality of the
949 energy estimator. In the ideal case the residual is zero
950 and doesn't depend on any variable. In reality even a good estimator
951 can show residuals versus Monte Carlo energy. The tab is displayed
952 after all cuts.
953
954 - sponde: added a new tab "EventDist" showing the unweighted real
955 absolute number of events of your sample after cuts. This tells
956 you how many events with this energy you had in your MC files.
957 The same information you get from the error bars of the weighted
958 histograms, but this is less intuitive.
959
960 - sponde: The spectrum plots now show the crab- and 1553-spectrum
961 for comparison. It is not meant to show these curves in
962 publications, they are only for production.
963
964 - sponde: The OriginalMC tree with the events produced by corsika
965 is now processed only once
966
967 - sponde: Finally fixed most annoying bug, which has effected the
968 last bin of the collection area. It was the problem that binnings
969 of root histograms are from 1 to n (included) but there was a C-like
970 loop in sponde from 0 to n (excluded). Now the loop also includes
971 correctly under- and overflow-bins. The worse thing with this is,
972 that for the events in the highest bin not only the bin-content
973 was wrong, but also the weights applied to these events, which could
974 in pricipal effect also other parts of the distribution (eg. due
975 to energy estimation). Fortunately it effected only a few events
976 in most cases.
977
978
979
980 *** Version 1.2 (2007/05/14)
981
982 - database: The database now has two new values Unsuitable50 and
983 Unsuitable01. They express the number of pixels which are
984 unsuitable for more than 50%, respectively more than 1%, of
985 all calibrated event. It is a more accurate number than the
986 previously used numbers, because they only take the first
987 calibration (ignoring the interleaved calibrations) into account.
988
989 - database: The database now has two other new values UnsuitableMax and
990 DeadMax. They express the maximum number of pixels which were
991 unsuitable, respectively dead, during the sequence. Because
992 of high pedestal rms (cars passing) a few events with very high
993 numbers of unsuitable pixels can happen. Not to suffer from this
994 effect we don't take the highest 0.1% of the numbers into account.
995
996 - general: fixed a bug which caused callisto and star to stop working
997 properly because the callisto output was currupted
998
999 - general: a script called scripts/makemovie has been added which
1000 simplified the process of producing several movies from a single
1001 sequence with different setup.
1002
1003 - callisto: Some more code cleanup. Started to remove old obsolete
1004 code from cvs.
1005
1006 - callisto: The extraction of the pedestal with the extractor was
1007 not random. It seems that extracting at one position is still biased
1008 (for example in the first or last slices we could still suffer from
1009 switching noise) Now it is completely random.
1010
1011 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1012 pedestal files) individual pixels could be skipped due to high
1013 variations. This was already the case for the pedestal extraction
1014 from the lo-gains since the beginning and properly handled
1015 there, but was introduced in the extraction from the pedestal files
1016 a while ago. To calculate the average value it was still divided
1017 by the number of events procesed not by the number of summands
1018 really summed. This let to a pedestal which was a tiny amount too
1019 small (for a few piels in the order of 0.1%). This led to an slightly
1020 positive offset of the randomly extracted pedestal for a few pixels.
1021 I doubt that this has a big effect on the result, because the effect
1022 on the individual numbers is quite small. Due to this it is suggested
1023 that you rerun your calibration to make sure you are without any
1024 avoidable bias.
1025
1026 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1027 the median rms of the absolute arrival time and expressed in significance
1028 levels. This replaces the old meaning of an abolute upper limit. An
1029 absolute upper limit doesn't make much sense, because in our data
1030 all arrival times are shifted at the same time (in fact it might be
1031 a shift of the artificial trigger w.r.t. to the light flash).
1032
1033 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1034 of the number of unsuitable pixels over the whole sequence. This
1035 is usefull mainly to judge if an intermediate calibration had
1036 problems.
1037
1038 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1039 of the number of dead pixels over the whole sequence. Dead pixels
1040 in this context are unmapped pixels, i.e. pixels which could not
1041 be interpolated, and thus are ignored in the further analysis.
1042
1043 - callisto: It is now possible to use the position of the maximum
1044 of the spline as arrival time instead of the leading edge even
1045 when using the integral for the signal. Therefor set the extraction
1046 type to kIntegralRel ("IntegralRelative") and the relative height
1047 ("HeightTm") to -1:
1048 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1049 MJPedestalC1.ExtractSignal.HeightTm: -1
1050
1051
1052
1053
1054 *** Version 1.1 (2007/04/27)
1055
1056 - general: The new class MGeomCamDwarf contains the camera geometry
1057 for our prefered Dwarf camera and can be used to create general
1058 geometries of roundish or hexagonal cameras.
1059
1060 - mars: The default cleaning is now abolute 8.5/4.0.
1061
1062 - mars: The resource file mars.rc now contains examples for MUX data
1063
1064 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1065 data containing only 10-bit information is still cooked down to
1066 8-bit, by cutting away the lowest 8-bit.
1067
1068 - merpp: When reading raw data the data is now stored in a single
1069 array. The lo-gain array is obsolete. The interface stays the same.
1070
1071 - callisto: To process the new MUX data use the resource file
1072 callisto_mux.rc
1073
1074 - callisto: The -root and -raw options to read merpped raw data have
1075 been removed
1076
1077 - callisto: If the -mc option is given the sequence-name can now be
1078 replaced by the MC sequence number
1079
1080 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1081 -mc option can now be omitted
1082
1083 - callisto: Started further simplification by removing obsolete
1084 dependancies on MCalibIntensity*Cams.
1085
1086 - callisto: removed unsused intensity calibration from MJCalibration
1087 for further simplification
1088
1089 - callisto: for simplification removed references to
1090 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1091 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1092 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1093 (this should at minimum change nothing at all, and at maximum
1094 improve thing if these containers where somewhere not handled
1095 properly)
1096
1097 - callisto: Added the option to write an event movie. Please use
1098 this option with care (huge files) but exessively to understand
1099 our events. For further documentation please refer to the
1100 IACT wiki
1101 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1102
1103 - callisto: Improved binning for the pulse position check histogram
1104
1105 - callisto: The code calculating the pulse position checknow takes
1106 the pedestal into account
1107
1108 - callisto: The arrival time is now stored with full precision this
1109 helps to get rid of artefacts in histograms. For the signal this
1110 is not necessray because it is displayed in log-scale anyhow
1111
1112 - callisto: Fixed a problem with internal exclusions. Pixels which
1113 have once been marked as unsuitable didn't get the necessary
1114 histograms filled anymore to be rechecked with each interleaved
1115 calibration.
1116
1117 - callisto: The relative arrival time resolution (the rms of the
1118 relative arrival time offset) is now checked against its
1119 median and the median deviation, instead of the average
1120 plus an absolute offset.
1121
1122 - callisto: The relative arrival time offset is now calculated
1123 w.r.t. its median not w.r.t. to an artificial reference pixel.
1124
1125 - callisto: The relative time calibration now marks pixels with
1126 outlaying offset as unsuitable
1127
1128 - callisto: The interleaved relative time calibration has been switched
1129 on. The advantage is that pixels which are marked as outliers
1130 now can recover. An improvement over time is not expected, because
1131 the relative time calibration seems stable.
1132
1133 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1134 option can now be omitted.
1135
1136 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1137 or the option "-mc" is specified as default the monte carlo datacenter
1138 paths (/magic/montecarlo/...) are used if not overwritten in the
1139 dataset file.
1140
1141 - ganymed: The output files now contain run- and event-number for all
1142 events, accessible as RunNumber.fVal and EvtNumber.fVal
1143
1144 - ganymed: Added a plot showing the source position in the camera also
1145 for wobble mode
1146
1147 - ganymed: In addition to the existing task which can be setup to
1148 be executed after Cut1 a final task called "EstimateEnergy"
1149 has been added, executed before writing the final output
1150 (ganymed00000000.root). The task setup in all three cases
1151 can be choosen individually. (For all three(!) cases you
1152 can for example choose MRanForestCalc. For examples see all
1153 sponde*.rc and all ganymed*rc)
1154
1155 - ganymed: If a container "MEstimatedEnergy" is found in the
1156 parameter list (eg. because it was setup by MEstimateEnergy)
1157 it will be written to the output file.
1158
1159
1160
1161 *** Version 1.0 (2007/02/16)
1162
1163 - database: Website to plot values from the database has been added.
1164
1165 - database: The rate of spark events as found by star is now kept
1166 and the rate after cleaning is now with spark events subtracted
1167
1168 - general: The changes to the interpretation of phrases lead to
1169 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1170
1171 - general: Added example files how you can create your own calendar
1172 (eg. as christmas present) with Mars. Just run
1173 root macros/tutorials/calendar.C
1174
1175 - general: Added a possibility to display grouped data in the plotdb.C
1176 macro (and similar macros). This allows to plot hourly, nightly,
1177 weekly, monthly and yearly averages.
1178 For more details see the plotall function of the macro
1179
1180 - general: fixed the error display of the camera display. It showed
1181 wrong results.
1182
1183 - general: fixed a memory leak when reading many MStatusDisplays
1184
1185 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1186 between a spherical and a parabolic mirror
1187
1188 - callisto: We have a new pulse position check which takes the properties
1189 of the extractor automatically into account. So no need to set
1190 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1191 left is done. If possible the lo-gain extraction start and hi-gain
1192 extraction end is changed accordingly. If no proper extraction range
1193 can be set (hi-gain too much to the left) an error is raised.
1194
1195 - callisto: New swapped pixels have been found and corrected
1196
1197 - callisto: Redone the signal extraction this includes:
1198 + Unified the algorithms to extract the pedestal for all pedestal
1199 extractions done
1200 + Unification of hi- and lo-gain into one array
1201 + Unification of hi- and lo-gain extraction for Spline and
1202 Digital Filter (means now exactly the same algorithm is used,
1203 not a copy-and-pasted one)
1204 + Store pedestal subtracted data in a common place
1205 + Improved extraction algorithms. If the algorithms search a
1206 maximum but don't find one they don't return the maximum anymore
1207 + Improved the extraction such that a information for signal
1208 and time which is consistent is returned
1209 + replaced the numerical spline with a (not slower) analytical
1210 solution
1211 + Lowered the saturation limit from 250 to 245 to make sure that
1212 we are far away in all pixels from problems with the clock-noise
1213 + The start of the lo-gain extraction is calculated from the hi-gain
1214 arrival time. In case of saturation an estimation is used.
1215 + the hi-gain window was extended to slice 16. This allows extraction
1216 of very late pulses in single pixels or of huge hadron showers.
1217 + Now uses the lo-gain extraction range for pedestal extraction,
1218 not the hi-gain range in the lo-gain
1219
1220 - callisto: New hi-/lo-gain calibration constants have been produced
1221 for all periods from the statistic of the whole period. They are
1222 now used automatically depending on the periods. The old constants
1223 where deviation in avarega about 2%-3%. The constants are very
1224 stable from period to period (<<1%) except for exchanged channels.
1225 In a few cases the constants used so far were off by 1%-2% (maybe
1226 temperature effects?)
1227
1228 - callisto: To gain obsolete space we do not write the
1229 MPedestalFundamental anymore. Also calibration and bad pixel
1230 treatment is not done for it anymore because it has never been used.
1231
1232 - callisto: Fixed a bug in the seuqence handling which caused the
1233 light condition to be ignored
1234
1235 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1236 basically the same as "Cleaned" but the distribution devided into
1237 the events fullfilling a spark cut or being rejected by it.
1238 This cut can be changed from star.rc (see example inside) by
1239 the "SparkCut" directive
1240
1241 - star: Star displays now the average individual pixel-rate (IPR) versus
1242 time and the average discriminator threshold (DT) of all pixels.
1243
1244 - optim: fixed a problem with the optim-macros which was due to a bug
1245 in the new phrase parsing
1246
1247 - ganymed: To get a nice FalseSource plot (instead of the all-information
1248 debug plot displayed as a standard plot) use the context menu
1249 somewhere between the two upper plots, click on "DrawNicePlot"
1250 and enjoy the result. (It is the same context menu which contains
1251 the other options)
1252 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1253
1254 - ganymed/optim/train: The cut program, trainings- and optimization
1255 macros could run with less files found than expected from the
1256 sequence-files. No the execution is stopped in this case.
1257
1258 - ganymed: now stores the dataset in the output file with all information
1259 contained (as sequence number, sequence path, data path) so that the
1260 used dataset file can be recreated complete from the output
1261
1262 - sponde: now also allows the uasge of random forest
1263
1264 - sponde: added a plot showing the cut efficiency
1265
1266 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1267 errors (eg. effecting the collection area) because the errors of the
1268 two histograms were swapped in the calculation, which makes a difference
1269 in the case the histograms contains weighted events. Aditionally the
1270 totalarea was incorrectly taken into account, which results in too small
1271 errors, which makes a difference at low statistics were the errors
1272 or the collection area dominate.
1273
1274
1275
1276 *** Version 0.10.3 (2006/10/23)
1277
1278 - database: Implemented ObservationMode flag in websites.
1279
1280 - database: For sequences there is now also the stoptime available on the
1281 websites.
1282
1283 - database: Removed ManuallyChanged flag from sequence-info websites,
1284 as it is not needed anymore with the new sequence building algorithm.
1285
1286 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1287 Class for calculation of confidence intervals (upper limits).
1288 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1289 Please read the class instruction of TRolke for more information.
1290
1291 - general: The programs now return 0xfe if the requested resource file
1292 doesn't exist.
1293
1294 - general: Errors comming from root itself are now not output to
1295 stderr anymore but to our default (colored) log-stream.
1296
1297 - general: Changed the interface to TFormula such that now everything
1298 is parsed by TFormula, which should allow to use phrases even
1299 without paranthesis correctly parsed.
1300
1301 - callisto: replaced the AdHoc number of effective integration slices
1302 in the digital filter by an average of the correct number, averaged
1303 over all possible set of weights. This also gives correct numbers
1304 for the lo-gains which were totally wrong before.
1305
1306 - callisto: drastically reduced memory consumption by not storing
1307 all intermediate calibration results in memory anymore (we might
1308 write them into a file in the future)
1309
1310 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1311 debug plot displayed as a standard plot) use the context menu
1312 somewhere between the two upper plots, click on "DrawNicePlot"
1313 and enjoy the result. (It is the same context menu which contains
1314 the "DrawAll" option)
1315 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1316
1317
1318
1319 *** Version 0.10.2 (2006/10/15)
1320
1321 - general: changed the building of the sequence files such, that
1322 the source-/project name in case of wobble-sources is not the
1323 source/project of the first data run anymore but the new generalized
1324 wobble source/project
1325
1326 - general: Added some functions to MAstro to calculate sun and
1327 moon properties
1328
1329 - general: Added two new macros (starvisday.C and starvisyear.C)
1330 which allow to plot the visibility of several stars in one day
1331 or of one star along one year
1332
1333
1334
1335 *** Version 0.10.1 (2006/10/11)
1336
1337 - general: HTML logging output was distorted... fixed.
1338
1339 - general: Changed the writing of the sequencefiles such that only
1340 as many pedestal files as giving at least 1000 pedestal events which
1341 are nearby the first calibration run are used as pedestal runs
1342
1343 - sponde: In the calculation of the collection area(s) and the
1344 distribution for MOnte Carlo and estimated energy the error
1345 calculation was wrong because root didn't take the errors
1346 properly into account... fixed.
1347
1348
1349
1350 *** Version 0.10 (2006/10/10)
1351
1352 - general: all executables now check consistency of the root version
1353 installed with the root version used for compilation. The return
1354 code in this case is 255.
1355
1356 - general: The algorithm to build seqeunces has been redesigned
1357 completly. It is now more flexible in terms of a resource file
1358 resources/sequences.rc which can be used to partly overwrite
1359 the default algorithm and defined the important part of the
1360 algorithm. It also takes correctly into account several ways
1361 of taking wobble-data. Currently the new algorithm doesn't take
1362 the number of pedestal events anymore into account (so a sequence
1363 could have much less than 1000 pedestal events and data runs are
1364 no-more used instead)
1365
1366 - general: a lot of small changes to make the code compatible with
1367 root 5.12/00 and gcc 4.1
1368
1369 - general: Fixed some warnings thrown if more warnings are switched
1370 on in the compiler
1371
1372 - general: Added a function to MMath which returns the Median of
1373 the distribution abs(y[i]-median) but at 68:32 division instead
1374 of 50:50, which is somehow the median counterpart of the rms.
1375
1376 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1377 even if they are compressed with gzip (recommended compression
1378 is with "-1")
1379
1380 - showplot:
1381 + batch mode creation of image files now works with root 5.12/00
1382 + added support for writing bmp (though it never produces
1383 bmp which can be read by programs like xv or gimp)
1384 + added support for xml
1385 + added new option to start the display with a different size, by
1386 --display-width=nnn or --display-height=nnn
1387 + added options to define the canvas size when the display is started
1388 --canvas-width=nnn or --canvas-height=nnn
1389 the option can also be used for batch-mode conversion
1390 + added an option which automatically fits the display size to the
1391 desktop-size: --auto-size
1392
1393 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1394
1395 - merpp: allow the reports to have 1000ms due to a bug in the camera
1396 program.
1397
1398 - callisto: New swapped pixels have been found and corrected. For
1399 details see MRawRunHeader::FixAssignment()
1400
1401 - callisto: Callisto now raises an error if one of the input files could
1402 not be opened.
1403
1404 - callisto: In some rare cases it could happen that in the signal
1405 extraction of the digital filter the extractor returned nonsense
1406 results due a wrong initializion of a variable (this happens in
1407 cases in which the extracted signal is exactly zero or the
1408 digital filter couldn't slide because of a too small extraction
1409 window, which could happen in the lo-gain extraction)
1410
1411 - callisto: The lo-gains have been marked as valid in some cases
1412 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1413 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1414 smaller than the number of slices (fLoGainWindowSize) needed
1415 by the lo-gain extractor
1416
1417 - callisto: Updated absolute calibration constants (muon calibration)
1418
1419 - callisto: fixed a bug which caused the hi-gain saturation not
1420 to be handled properly in the spline (the position of the
1421 saturation was calculated incorrectly)
1422
1423 - callisto: fixed a bug which gave weird results if hi- _and_
1424 lo-gain could not be extracted properly. In some cases hi-
1425 and lo-gain have not been extracted at all and the random result
1426 got calibrated. In other cases the hi-gain was saturating and the
1427 lo-gain has not been extracted. For this a completly arbitraty
1428 scale factor was applied to the result from extracting the
1429 charge of the saturating hi-gain.
1430
1431 - callisto: improves handling of extracted signal if lo- and/or
1432 hi-gain could not be extracted properly. If no appropriate
1433 calibration of either the signal or the arrival time is possible
1434 the pixel is now markes as unsuitable instead of estimated.
1435
1436 - callisto: Fixed a problem in the spline extraction which gave
1437 weird results if the signal was extracted from the first (and
1438 highest) slice (as a workaround extraction from the first
1439 slice has been forbidden)
1440
1441 - callisto: Fixed a bug regarding the use of the QE which doesn't
1442 effect the result because the default is used anyhow.
1443 (The bug was there since 14/07/2005)
1444
1445 - callisto: Changed the default for fgLoGainStartShift to -2.4
1446
1447 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1448 factors to be always 10 for all pixels as soon as the first
1449 calibration update has happend.
1450
1451 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1452 was off by more than one slice (which gives wrong values for
1453 pixels which have saturated the hi-gain) This was a problem
1454 mainly for timing studies, not so much for the automatic standard
1455 analysis. Also the values for the Spline have been changed slightly:
1456 + Digital Filter from 1.70 to 0.95
1457 + Spline from 1.39 to 1.30
1458 The numbers were sorted out by an extensive test in the
1459 test-database.
1460
1461 - callisto: Removed the tab showing the average calibrated arrival
1462 time. It never gave useful information.
1463
1464 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1465 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1466 and both were extracted because the hi-gain was above the
1467 LoGainSwitch.
1468
1469 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1470 lo-gain pulse position (after application of LoGainOffset, which
1471 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1472 have saturated and both were extracted because the hi-gain was above
1473 the LoGainSwitch.
1474
1475 - callisto: After extensive tests a new threshold level for determination
1476 of the pulse position has been found at 50phe. This is due to the
1477 fact that for lower pulses the arrival time changes its average
1478 behaviour dramatically. It tends to the average of the extraction
1479 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1480
1481 - callisto: Added two more plots to the calibration part. The average
1482 extracted signal and the average extracted arrival time as
1483 extracted by the signal extractor (This can help debugging problems
1484 because it doesn't involve a fit)
1485
1486 - star: changed the fit for the effective on time such that initial
1487 values are calculated automatically now instead of using build
1488 in values. This makes the fit more indepedant of the underlaying
1489 rates. With a test of ~350 sequences in the test database it could
1490 be shown that the new fit gives the same result +/-1sek.
1491 The highest deviation was +5s the lowest -10s. You can now control
1492 the bahaviour with two resource values:
1493 MHEffectiveOnTime.FistBin: 3
1494 MHEffectiveOnTime.NumEvents: 12000
1495 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1496 from the resulting gamma candidates
1497
1498 - star: The Center histogram in MHHillas is now by default displayed
1499 with the colz draw-option
1500
1501 - ganymed: now produces valid error codes if failed
1502
1503 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1504 with the option "hadronness" instead of "area" or "both" if
1505 you want to use both cuts. The hadronness cut includes a fixed
1506 cut in hadronness (index 8) and a fixed cut in size (index 9).
1507
1508 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1509 the M3Long of the anti source to be not properly evaluated
1510 (actually is was evaluated as a unique random number) in case
1511 of optimization with anti-theta cut switched on. This might have
1512 lead to improper, but not necessarily wrong, optimization results.
1513
1514 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1515 how to use random forest
1516
1517 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1518 ganymed_onoff.rc. Seems to be unintentional that they were different.
1519
1520 - sponde: Since the introduction of the possibility to define a
1521 normalization energy instead of using the integral the default
1522 was not using the integral anymore but a normalization energy of
1523 1GeV. It is now the integral again.
1524
1525 - sponde: Fixed a problem in the weighting which did not allow
1526 a MC slope of -1.
1527
1528
1529
1530 *** Version 0.9.6 (2006/05/24)
1531
1532 - general: changed the binning of the azimuthal profile of the camera
1533 such that it is aligned with the 60deg boundaries.
1534
1535 - merpp: better handling of problems with the TH, TD part of the
1536 CC-REPORT for files older than 200507190 and 200412210
1537 respectively
1538
1539 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1540
1541 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1542
1543 - callisto: if an arrival time is extracted outside the fadc range is
1544 was set to the boundary before. Now a random number is assigned
1545 instead to avoid unfortunate coincidences of arrival times just
1546 by this arbitrary value.
1547
1548 - callisto: added a new option to callisto.rc which allows
1549 to set the maximum arrival time difference allowed for the
1550 badpixel algorithm to determin whether a pixels belongs to a shower:
1551 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1552
1553 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1554 to 0.9 as suggested by Stefan due to a recent study on the fraction
1555 of pixels surviving the image cleaning
1556
1557 - callisto: switched off error in case of "pulse is too much to the left"
1558
1559 - callisto: The extraction window is not adapted anymore. This means that
1560 the pulse is extracted from the full range. The draw-back is that the
1561 background (pedestal) will become slightly higher. Switching on/off
1562 the PulsePosCheck in the callisto.rc only effects filling the
1563 histograms.
1564 WARNING: If the pulse is too much to the left data is calibrated!
1565 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1566 in the database to make sure that your data is valid!
1567
1568 - star: Show also the number of stars correlated correctly by the
1569 starguider
1570
1571 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1572 than one off-source region in wobble-mode. To use it add the following to
1573 your ganymed_wobble.rc:
1574 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1575 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1576 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1577 + Cut1.ThetaCut: None
1578 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1579
1580 - ganymed: in the case the latest report is older than a default (currently
1581 one minute) and the current report will be skip the starguider
1582 correction and calibration will be reset. The maximum age can be
1583 setup from ganymed.rc by (minutes):
1584 MPointingDevCalc.MaxAge: 1.5
1585
1586 - ganymed: A first implementation showing all size-bins for the theta-sq
1587 resp. alpha-plots in a single tab automatically
1588
1589
1590
1591 *** Version 0.9.5.1 (2006/05/05)
1592
1593 - general: Added a new option "zdiff" to the Makefile which runs
1594 "cvs diff" as "make diff" would do, but with compression
1595
1596 - general: accelerated MTFillMatrix (used for eample in all training
1597 and optimization macros) by skipping some obsolete calles in the
1598 eventloop the first and second loop could be accelerated by ~20%
1599
1600 - general: Added a missing feature in the MFilterList class which
1601 prevented MFEnergySlope from working correctly in trainenergy.C
1602
1603 - general: Accelerated the random forest training and usage a bit
1604
1605 - merpp: Adapted to new raw data file format version 6
1606
1607 - merpp: fixed a problem with reading the starguider reports
1608 after 6.3.2006
1609
1610 - callisto: At some times six pixels had to be exchanged manually in the
1611 data. If the pixels to be swaped are both not found, an error was raised
1612 and calibration was stopped. Now it is assumed they are intentially not
1613 mapped and the Error has been changed to a Warning.
1614
1615 - star: Added new image cleaning based on the arrival time of the shower.
1616 The new cleaning can be accessed using the parameter "Time" instead of
1617 the the old one (like "Absolute) in the star.rc-file.
1618 Recommended parameters:
1619 + MImgCleanStd.CleanLevel1: 8.2
1620 + MImgCleanStd.CleanLevel2: 5
1621 + MImgCleanStd.CleanRings: 2
1622 + MImgCleanStd.KeepSinglePixels: No
1623
1624 - star: Simplified the calculation of the effective on time. By letting
1625 the fit start in the third bin the result should become more stable.
1626 The fit quality is now ignored for the theta-plot which is not used
1627 in the analysis later. Still better pre-cut which, for example,
1628 remove events triggered by car-light (rate changing on a short
1629 time-scale) are missing.
1630
1631 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1632 for optimization (kWeakSource) which is suggested by the Berlin
1633 people for weak sources.
1634
1635 - macros: plotdb.C:
1636 + if no dataset and no time-interval is given only sequences with
1637 an effective on-time above five minutes are plotted anymore
1638 + added a new tab "RelTime" displaying the relative on-time
1639 (effective on-time divided by the observation time)
1640
1641 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1642 the optimization became a lot faster
1643
1644 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1645 To display them just delete the pads displayed on top.
1646
1647 - ganymed: fixed a bug which could cause strange behaviour in wobble
1648 mode if no starguider information was available due to an incorrect
1649 initialization of the starguider calibration
1650
1651 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1652 be changed from within the plot. It can also be setup from the
1653 resource file using:
1654 + MHDisp.fScaleMin: 0.325
1655 + MHDisp.fScaleMax: 0.475
1656
1657 - ganymed, showplot: Fixed a problem with the fit to the off-data
1658 (HistOff) which could cause a time lag or an inifinite loop.
1659 The bug did not effect the results at all.
1660
1661 - sponde: Added a new tab showing the effective collection area after
1662 trigger (including the software trigger)
1663
1664 - sponde: MMcSpectrumWeight has a new option which allows to define
1665 the scaling factor not by the integral of the events but at
1666 a defined energy:
1667 e.g. MMcSpectrumWeight.NormEnergy: 200
1668
1669 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1670 eventloops the loop could be accelerated by ~20%
1671
1672
1673
1674 *** Version 0.9.5 (2006/03/13)
1675
1676 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1677 and added the standard Disp-parametrization
1678
1679 - macros: added a new macro datacenter/macros/plotstat.C allowing
1680 to plot statistics about the data processing
1681
1682 - macros: added a new macro to plot the muon correction coefficients
1683 versus period (macros/plot/mucal.C)
1684
1685 - showplot: path inflation for ganymed files was broken
1686
1687 - callisto: Fixed an important bug. When the number of saturating pixels
1688 were calculated the bad pixel information already available from the
1689 calibration was ignored. This yields wrong values in case pixels
1690 are broken and saturate all the time or randomly.
1691
1692 - callisto: Updated Muon calibration constants. Spline data now also uses
1693 different values for different periods
1694
1695 - star: The time-evolution shown in the effective on-time plot now displays
1696 the axis range (if there are no holes it should be similar to the
1697 effective on-time)
1698
1699 - star: Added two new image parameters:
1700 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1701 the three pixels next to the center of gravity and the size
1702 + MNewImagePar.fConcCore: The ratio of the signals of all
1703 pixels inside or touching the ellipse and the size
1704
1705 - ganymed: now stops in requested source isn't found in catalog file
1706
1707 - ganymed: Many improvements to the phi-plot in wobble mode:
1708 + with a template the ideal background is displayed
1709 + a possible camera inhomogeneity is taken into account
1710 + the anti theta cut is better supported
1711 + the phi cut is automatically calculated from the theta cut
1712 See the examples in ganymed_wobble.rc for more details.
1713
1714 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1715 times the bin-width instead of the absolute energy
1716
1717 - ganymed: New cuts for on/off and wobble mode
1718
1719 - ganymed: The smearing of the False Source plot has been increased
1720 to 0.06
1721
1722 - ganymed: The starguider calibration can now be changed from the
1723 resource file.
1724 See the examples in ganymed*.rc for more details.
1725
1726 - ganymed: added a new option for on-/off-observations
1727 MJCut.RandomSourcePosition
1728 If switched on the distribution of observation time of the source
1729 position in the camera is calculated from the on-data and randomly
1730 applied with this distrbution to the off-data.
1731
1732 - ganymed: by skipping some obsolete calles in the eventloop the
1733 first and second loop could be accelerated by ~20%
1734
1735 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1736 position in the off-data randomly according to its distribution in the
1737 on-data.
1738
1739
1740
1741 *** Version 0.9.4.3 (2006/02/13)
1742
1743 - general: Fixed a bug in most of the programs which prevented the
1744 compile date in the startup message to be displayed
1745
1746 - general: Simplified program calls. The following abbreviations
1747 are now possible:
1748 showlog callisto 55599
1749 showplot signal 55599
1750 star 55599
1751 callisto 55999
1752 ganymed 2
1753 In this cases the corrsponding root-, log-, sequence- or dataset-
1754 filename is automatically compiled using the default datacenter
1755 paths ("/magic/*")
1756
1757 - general: Fixed a long outstanding bug which made axis tick marks
1758 disappear if MDataFormula was used (eg. abs(x))
1759
1760 - general: Updated MMath with new functions to calculate the results of
1761 a exponential, logarithmic and powerlaw fits analytically.
1762
1763 - general: Updated some macros with comments:
1764 + macros/optim/optimdisp.C
1765 + macros/optim/optimenergy.C
1766 + macros/optim/optimwobble.C:
1767
1768 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1769 files) now allows adding a pre-cut like in the optimization. E.g. this
1770 is useful to perform g/h-separation cuts before training the random
1771 forest.
1772
1773 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1774 correctly assigned in the raw data assignement table. A fix to correct
1775 the assignment tabel have been implemented.
1776
1777 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1778 by 90, 180 and 270 deg.
1779
1780 - general: the macro plotdb.C now allows to highlight sequences belonging
1781 to a datset. For more details see the descritions in the macro.
1782
1783 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1784 of the display, it gave wrong results espacially for big sizes.
1785 Now the embedded canvas should always have a ratio width/height=3/2.
1786 The "Size" options have been updated with values fitting the 3/2
1787 size ratio.
1788
1789 - RanForest:
1790 + Updated the random forest classes to support also the
1791 regression method implemented by Thomas H.
1792 + added new tutorial macro how to train the random forest
1793 for energy estimation (macros/optim/rfenergyest.C)
1794 + new classes to train the random forest (still in development)
1795 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1796 + new tutorial macros for random forest training in macros/train
1797 trainenergy.C, traindisp.C, trainseparation.C
1798
1799 - mars: now allows to setup a cut in the resource file mars.rc to choose
1800 the events to be displayed, eg:
1801 Cut.Condition: {0} && {1}
1802 Cut.0: MHillas.fSize>100
1803 Cut.1: MHillas.fSize<900
1804
1805 - merpp: Made aware of the new .rep format 200510250. This includes
1806 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1807 the discriminator thresholds (MCameraTD) and the disciminator
1808 delays (MCameraTD). All of them come with the CC report and are therefor
1809 written to the CC tree.
1810
1811 - callisto: fixed a bug in the calculation of the arrival times in
1812 the Digital Filter. They were all shifted by the same amount
1813 fHiGainFirst. This caused an offset in the order of the position of
1814 the left border of the extraction window in the times calculated
1815 from high-gain and from low-gain. The bug effected only the absolute
1816 arrival times. The bug was there since 30.1.2005.
1817
1818 - callisto: Changed the ExtractionWindow for the pulse position check
1819 such that the camera inhomogeneity becomes as less as possible and
1820 comparable to the pulso position check switched off. More details
1821 on the study will be given at our result web-page.
1822
1823 - ganymed: ganymed.rc, ganymed_onoff.rc:
1824 changed to new cuts trained with 1ES1218 and Crab-data
1825 for maximum sigma*log10(excess)
1826
1827 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1828 a new option was implemented to estimate Disp (CalcDisp)
1829
1830 - ganymed: Implemented two new options which allow
1831 to overwrite the default path to search for the sequence files
1832 --ins=/magic/sequences
1833 and where to search for the image data
1834 --ind=/magic/data/star
1835
1836 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1837 dx/dy from the resource file by
1838 MSrcPosCorrect.Dx
1839 MSrcPosCorrect.Dy
1840
1841 - ganymed: fixed reading the source catalog. Only as many chars
1842 as the requested source name had were compared (If a source
1843 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1844 were requested it could happen that the coordinates of
1845 "1ES1218" were read) The source coordinates are now printed
1846 in addition to its name to the logging output.
1847
1848 - ganymed: changed the background fit in the case of a ThetaSq function
1849 from a polynomial to a exponential, this should give a big improvement
1850 for on-only analysis'
1851
1852 - ganymed/sponde: Calculation of the error of single size-/energy-
1853 bins now uses Li/Ma (5) instead of LiMa (17)
1854
1855 - sponde: Added a plot E^2*dN/dE
1856
1857 - sponde: The energy estimator plot should now show values like
1858 they are commonly used.
1859
1860 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1861 (a powerlaw with cutoff didn't work before)
1862
1863
1864
1865 *** Version 0.9.4.2 (2005/10/01)
1866
1867 - general: added new tutorial macro macros/tutorials/threshold.C:
1868 how to calculate the threshold
1869
1870 - general: added a new game. Start it from the interpreter with
1871 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1872 and MagicReversi)
1873
1874 - general: neighbor pixels in MGeoms are now sorted clockwise
1875
1876 - merpp: made aware of new format 20050829-0
1877
1878 - callisto: New scale factors from muon analysis, stored in new
1879 resource file resources/calibration.rc
1880
1881 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1882 the eventloop if something went wrong. This is necessary for the
1883 automatic processing
1884
1885 - callisto: Implemented a new treatment for the time information
1886 developed by S.Ruegamer, this should give much better response than
1887 the old very primitive algorithm. This is especially important
1888 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1889 treatment was buggy! As neighbor pixels to interpolate the
1890 arrival times always the pixels 0 to 5 were taken)
1891
1892 - callisto: In addition to the new treatment of arrival times the
1893 decision of the treatment whether a pixel contains shower
1894 information or not is used to improve the signal interpolation
1895 further. Previously interpolated pixels showed a non-zero signal
1896 do the peak searching signal extractors. Having a signal pixel
1897 beside raised the signal above the cleaning level. Thus the
1898 pixel survived cleaning to often but with a too low mean signal.
1899 By replacing empty pixels with a gaus (mean and rms from the
1900 corresponding Area entries in MPedPhotCam) this effect can
1901 be supressed.
1902
1903 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1904 got lost when the events were stored by the calibration... fixed.
1905 (This was no problem for normal image cleaning because the pixel
1906 content was artificially set to 0 not surviving standard cleaning
1907 algorithm)
1908
1909 - callisto: Fixed a bug which caused the random and peak-search pedestal
1910 extracted with an extractor to be exchanged for the first (roughly)
1911 500 events (*Extractor and *ExtractorRndm).
1912 (They were simply exchanged in callisto.cc) This bug might have been
1913 introduced in Mars 0.9.4 when the order of calculation of the two
1914 types of pedestal in callisto got exchanged. The bug only effects
1915 the first seconds of data of each sequence.
1916
1917 - star: Taking the arrival time of Muons into account the calculation
1918 of the parameters could be made independant of the noise
1919 (pedestal rms). The dependance was due to the bias of the peak search
1920 extractor. Now only a ZA dependamcy is left which is not yet fully
1921 understood.
1922
1923 - ganymed: The sequences were still not sorted correctly in any case,
1924 because they were sorted by the full qualified path name. Now they
1925 are sorted by their sequence number.
1926
1927 - ganymed: new values for the spark-event-cut
1928
1929 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1930
1931
1932
1933 *** Version 0.9.4.1 (2005/08/18)
1934
1935 - callisto: fixed some problems with the calibration in case of
1936 inteleaved events. Therefor the final and some intermediate
1937 fits are skipped which would take place on partly filled #
1938 histograms and gave wrong results or failed completely.
1939
1940 - callisto: If the intermediate finalization of the histograms
1941 calculating the mean charge of the calibration signal fails
1942 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1943
1944 - ganymed: Fixed some bugs which caused problems in On-only mode.
1945 Still the false source plot doesn't give reasonable results.
1946
1947
1948
1949 *** Version 0.9.4 (2005/08/05)
1950
1951 - general: Fixed the ZA binning. It did not correctly fit the
1952 MC binning
1953
1954 - general: Added a class to correct for the missfocussing in
1955 April (MSrcPosCorrect)
1956
1957 - general: Random Forest energy estimator should now work properly
1958
1959 - general: MHCamera now displays the profiles in deg instead of mm
1960
1961 - general: MH::SetPalette offers a lot of new palettes
1962
1963 - general: MHillas - the case of CorrXY==0 is now handled properly
1964
1965 - general: implemented the possibility to change the line and
1966 marker style of a sky-grid drawn by MAstroCatalog
1967
1968 - general: Runs in sequences and datasets are now automatically
1969 ordered (it is assumed that the order of their filenames correctly
1970 represents the order of observations) to ensure correct reading
1971 of the subsystem data
1972
1973 - general: Runs cannot be added to a sequence twice anymore. Also
1974 Sequences cannot be added twice anymore to a dataset.
1975
1976 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1977 It gave wrong results by 1./2pi
1978
1979 - showplot: got a new option to start a root interpreter, too
1980
1981 - mars: now displays a rough estimate of Disp and the third moment
1982
1983 - mars: now displays the event time MTime if available
1984
1985 - mars: show muon parameters graphically
1986
1987 - mars: now the file to open can be given as commandline
1988 argument
1989
1990 - merpp: Added support for new arehucas version >= 200507190
1991 implementing values for three temperature sensors in the
1992 counting house (MCameraAUX) and the name of the HV settings file
1993 (MCameraHV).
1994
1995 - merrp: Also fixed some problems with wrong versions numbers stated
1996 by arehucas and implemented some fixed for old versions (<200407070)
1997
1998 - callisto: MCalibrationHiLoCam can now be printed from its context
1999 menu, eg in the TBrowser
2000
2001 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2002 - 1.39 (MExtractTimeAndChargeSpline)
2003 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2004 This is important mainly for timing studies.
2005
2006 - callisto: Changed limits in MHCalibrationChargeCalc from
2007 - -100.125 to -98 (fgChargeHiGainFirst)
2008 - 1899.875 to 1902. (fgChargeHiGainLast)
2009 - -100.25 to -99 (fgChargeLoGainFirst)
2010 - 899.75 to 901. (fgChargeLoGainLast)
2011 Introduced new limits:
2012 - fgNumLoGainBlackoutLimit: 0.05
2013 - fgLoGainBlackoutLimit: 3.5
2014 - fgLoGainPickupLimit: 3.5
2015
2016 - callisto: The handling of automatic weights for the digital filter
2017 has been improved. There are now new calibration weights special
2018 for Monte Carlo calibrations.
2019
2020 - callisto: Updated Muon scale with latest results (1% difference
2021 for most data, 5% for Mar/Apr'05)
2022
2023 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2024 was saturated and the blackout-events in the low-gain exceed the
2025 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2026 This excludes those pixels which have a saturating high-gain
2027 channel, but the low-gain switch does not switch often enough
2028 to make the distribution reliable.
2029
2030 - callisto: fix a bug counting the number of saturated events. Up to now,
2031 the number of saturated slices was counted (which is one for a not too
2032 high number), but for some (pathological) pixels, many more slices
2033 saturated and produced wrong limits.
2034
2035 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2036 + MCalibrationRelTimeCam.CheckFitResults: Yes
2037 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2038 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2039 + MCalibrationRelTimeCam.CheckOscillations: Yes
2040
2041 - callisto: introduce max. number of events for intercalibration,
2042 the rest gets skipped. Default: 4096
2043 The calibration causes too many un-reliable pixels if more
2044 than about 5000 events are treated (@500 Hz) because of the
2045 mode hopping of the VCSels. However, in the past, some
2046 calibration runs have been taken (erroneously) with more
2047 than 5000 events, especially the intensity scans where
2048 a good precision is needed.
2049
2050 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2051 photo-electrons for the spline extractor by 1-2% (correctly).
2052
2053 - callisto: The intercalibration is now done using a full f-factor
2054 method instead of a simple update. This makes things slower but
2055 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2056 changes.
2057
2058 - callisto: MPedestalY3 now uses the same extraction range as the data
2059 as calculated by MPedestalY2
2060
2061 - callisto: A check of the fraction of allowed unsuitable (10%) and
2062 unreliable (30%) pixels has been addded when the conversion is
2063 calculated from interleaved events
2064
2065 - star: fixed a bug which caused MEffectiveOnTime containers not to
2066 be written. In the worst case they were skipped almost all, in the
2067 best case they were all ok. It depends on how often the new value
2068 was assigned just with an event which was skipped later by another
2069 task
2070
2071 - star: new histograms MHPointing and MHRate
2072
2073 - star: New tab (Currents) displaying the time evolution of the mean
2074 DC currents
2075
2076 - star: New tab (MeanRms) displaying the time volution of the mean
2077 Pedestal Rms
2078
2079 - star: Output now contains MReportStarguider
2080
2081 - star: Improved muon analysis. Due to the absense of a constant
2082 for the gaus fit for arc width and the fact that the arcwidth
2083 plot was a histogram instead of a profile the resulting psf
2084 became pedestal rms dependant
2085
2086 - ganymed: added new plot (MHPhi) for wobble mode as described in
2087 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2088
2089 - ganymed: corrects now (correctly?) for the misspointing in
2090 May/April 05
2091
2092 - ganymed: Two new default templates for ganymed.rc are avilable:
2093 ganymed_onoff.rc and ganymed_wobble.rc
2094
2095 - ganymed: The first version of MFMagicCuts has been released
2096
2097 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2098
2099 - ganymed, sponde: There are two new options to determin the number
2100 of bins for the signal region (NumBinsSignal) and the number of
2101 total bins (NumBinsTotal) in the MHThetaSq histogram
2102
2103 - ganymed: optimized palettes for MHDisp
2104
2105 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2106 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2107 sqrt(2) to large
2108
2109 - ganymed: The false source plot (MHDisp) is now based on Disp
2110 and a background model determined in the first loop is
2111 subtracted
2112
2113 - ganymed: MFMagicCuts are now available in the cvs. The correct
2114 solution for the disp ambiguity problem is now calculated using
2115 the third moment. The third moment cut therefor is skipped.
2116
2117 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2118 already determined by the third moment along the major axis and
2119 so its actual sign is aligned along the major axis of the shower.
2120
2121 - ganymed: If starguider data is available it is taken into account
2122 when calculating the source position. This is especially important
2123 for wobble data at high zenith angles and culmination data.
2124
2125 - ganymed: If available the starguider data is taken into account as
2126 good as it is possible without a starguider calibration. To switch
2127 it off add
2128 MPointingDevCalc.MaxAbsDev: -1
2129 to your ganymed.rc
2130
2131 - sponde: the zenith angle distribution is now weighted instead of
2132 choosen by default. This gurantees higher statistics in the highest
2133 and lowest energy bins. To switch this behaviour off use...
2134
2135 - sponde: now automatically displays the energy threshold
2136
2137
2138
2139 *** Version 0.9.3 (2005/06/03)
2140
2141 - general: MMcEvt now derived from MMcEvtBasic which should
2142 have no influence on compatibility with older camera files
2143
2144 - general: Implemented a new option to MReadReports which allows
2145 to force reading of the first event of some trees (eg. Drive-tree)
2146 before any other tree.
2147
2148 - general: Made a fix to MPointingPosCalc which assumes that the
2149 run-type is real-data if Process is called before ReInit, such
2150 that also the very first Drive-events in a run are treated
2151 correctly.
2152
2153 - shoplot now displays the filename in the title bar of the window
2154
2155 - merpp: new options: --auto-time-start --auto-time-stop which
2156 allow to cut updating with slow-control at the start- or
2157 (previousle --auto-time only allowed: and) stop-time of
2158 the run stored in the runheader.
2159
2160 - callisto: changed default of fgFallTimeHiGain in
2161 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2162 already set as default in callisto_Dec04Jan05.rc
2163
2164 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2165 now changes the filename for new weights automatically for
2166 cosmics, MC and for different calibration colors.
2167
2168 - callisto: a problem with the order of some code cause the
2169 name of the weights file in MPedestalY2 to be ignored.
2170 Wrongly the calibration_UV weights were used instead
2171 of the cosmics weights set in callisto.rc.
2172
2173 - callisto: should allow ct1 pulser data when the color is
2174 explicitly set also for pretty new runs
2175
2176 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2177 to introduce an additional scale factor (should be around 1)
2178 to adapt for slight deviations in different extractors from
2179 the MC calibration. For MC calibrations the scale factor
2180 is fixed to 1
2181
2182 - callisto: MFCosmics should handle very high signals a bit
2183 more accurate now
2184
2185 - callisto: when calculating the mean pedestal rms for different
2186 pixel sizes or sectors also kUnsuitableEvt is now taken into
2187 account - not only kUnsuitableRun
2188
2189 - callisto: '-raw' option is now the default
2190
2191 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2192 This has the advantage that mean values in the calibration (eg
2193 arrival times) are calculated more accuratly.
2194
2195 - callisto: In the resource file callisto_Dec04Jan05.rc
2196 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2197
2198 - callisto: new Hi-/Lo-Gain intercalibration constants
2199 hilocalib_sp1.root and hilocalib_sp1_mc.root
2200
2201 - callisto: changed default for MJPedestalY2.MaxEvents
2202 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2203
2204 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2205 has changed from 9.0 to 6.0. This is necessary to exclude two very
2206 ringing pixels in September which - when kept - destroy the image
2207 cleaning around them (Markus G.)
2208
2209 - callisto: (!) The Muon analysis of all data taken so far has
2210 suggested that different extractors give slightly different
2211 absolute results after calibration, due to there different
2212 handling of the calibration- and cosmics pulse shape. Although
2213 the over all calibration seems to be a bit to pesimistic (or
2214 the MC seems to be a little bit - 3-5% - too much attenuated).
2215 There for correction factors have been introduced which correct
2216 the calibration constants by
2217 0.956937799 for Digital Filter (callisto.rc)
2218 and
2219 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2220 calibration. The main advantage is, that both data types can
2221 be easily analysed together and compared to the same MC sample.
2222 The factors are choosen such, that the reference is now a
2223 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2224
2225 - star: fixed a bug which caused the first bin of the histograms
2226 vs time to disapear in PostProcess. This gave wrong results
2227 on the screen. The output and all following programs not
2228 directly accessing the histograms haven't been affected
2229
2230 - star, ganymed: Made sure that always the first Drive-tree event
2231 is read and Processed before the first data event was read.
2232
2233 - ganymed: implemented the possibility to replace the standard
2234 false source plot with a different one. For example: If
2235 you want to use a Disp based FS plot use the resource:
2236 NameHistFS: MHDisp
2237 For details about the requirements of these plots look
2238 at the corresponding classes
2239
2240 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2241 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2242 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2243 case MAlphaFitter is setup correctly. For On-Only optimization
2244 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2245 RunOn() instead of Run(). For energy estimation MJOptimize
2246 has been replaced by MJOptimizeEnergy
2247
2248 - sponde: The input MC spectrum can now be weighted to fake a
2249 different spectrum. This is done via MMcSpectrumWeight. For
2250 more details see the class description and sponde.rc
2251
2252 - sponde: The paremeter comparsion plots are not scaled by
2253 their entries anymore. Instead the MC plot is scaled by using
2254 the result spectrum of the analysis. If the input MC spectrum
2255 and the result spectrum has different slopes the absolut
2256 normalization is normally wrong.
2257
2258
2259
2260 *** Version 0.9.2 (2005/05/20)
2261
2262 - general: Changed the default paths for calibrated data and image
2263 files. (The implemented access to these files doesn't yet exist)
2264
2265 - general: support for MRunIter has been removed from the job classes
2266 (use the setter functions of MSeqeunce instead)
2267
2268 - general: ProcessFile has been renamed to Process in all job classes,
2269 because ProcessFile is missleading
2270
2271 - general: The storage of the palette in MHCamera is now possible
2272
2273 - general: new bits describing unsuitable and unreliable pixels have
2274 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2275 kDeadPedestalRms, kFluctuatingArrivalTimes
2276
2277 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2278 versions newer than V200404070
2279
2280 - general: support for cc file versions newer than V200504130. Added
2281 support for active loads (MCameraActiveLoad) and central pixel
2282 (MCameraCentralPixel)
2283
2284 - general: added new histograms for image parameters versus size
2285 (MHVsSize)
2286
2287 - general: The eventloop now automatically calls PrintStatistics
2288
2289 - Status Display: Improved support for printing:
2290 + A default can now be set in .rootrc (for more details see
2291 MStatusDisplay::PrintPS)
2292 + A print dialog is opened so that printer and command line
2293 can be canged
2294
2295 - showlog: improved such that it handles different verbosity levels
2296 more accurate now. This mean you can suppress output when
2297 using showlog.
2298
2299 - showplot: improved
2300 + The new graphics formats have been implemented
2301 (pdf, svg, png, jpg and xpm)
2302 + Implemented an interface for printing. Because you can change
2303 the printing command from the command line you can use all
2304 the nice postscript tool. To print a booklet for example call:
2305 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2306 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2307 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2308
2309 - callisto: fixed a bug in the recognition of the calibration bit
2310 pattern. Concerns only intensity calibration. (The strength of the
2311 intensity has been updated in some cases)
2312
2313 - callisto: add a filter against PIN Diode events when running over
2314 calibration runs since some of the recent calibration runs have
2315 been taken with Pin Diode.
2316
2317 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2318 39943, 44833 in the calibration (MCalibColorSet)
2319
2320 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2321 been set to 1e-18 in callisto_Dec04_Jan05.rc
2322
2323 - callisto: in callisto_Dec04Jan05.rc: set value for
2324 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2325 statistics for the calculation of the mean pulse time
2326 of the cosmisc
2327
2328 - callisto: the charge limit in the calibration has been raised
2329 from 2.5 to 4.5
2330
2331 - callisto: new setup read from callisto.rc
2332 + MCalibCalcFromPast.fNumEventsDump
2333 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2334 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2335
2336 - callisto: MExtractTimeAndChargeSpline extractor:
2337 + The integration ranges were shifted by 0.2 FADC slices to the right.
2338 + unreliable handling of floating point values caused different
2339 results on different platform or with different compiler options:
2340 The new algorithm is numerically exact and more accurate because
2341 it doesn't calculate the integration position by multiple times
2342 adding the step-size (which results in numerical uncertanties
2343 exspecially if multiplied with large numbers)
2344 + A lot of fixes have been introduced which effects integrating the
2345 spline at the edges of the valid range. In this case any memory
2346 was randomly accessed. This behaviour can be tested replacing
2347 all MArrayF by TArrayF which perform a range check (but of course
2348 they are a lot slower)
2349 ! No result obtained with the Spline before can be trusted! Due to
2350 random memory access it might by completely random!
2351
2352 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2353 + extraction range in the high gain to 4.
2354 + weights file to cosmics_weights46.dat
2355
2356 - callisto:
2357 + introduce the check for fluctuating arrival times.
2358 + set charge limit to from 2.5 to 4.5
2359 + introduce asymmetric exclusion due to "deviating number of phes":
2360 Default: -9.0 +4.5
2361 + make deviating number of phes unsuitable (see David's findings).
2362
2363 - callisto: fixed the display of unsuitable pixels. The old change
2364 to a real profile in MHCamera broke it.
2365
2366 - callisto: The cosmics filter is used in MJCalibration now
2367 independant of the pulser color (formaly it was used only for
2368 CT1-pulser data). The threshold of number of max empty pixels
2369 has been raised from 2% to 5% in MJCalibration. The maximum
2370 fraction of rejected event is 50% otherwise the calibration has
2371 failed. The filter now ignores unsuitable pixels.
2372 Setup the filter from callisto.rc using "ContCosmics"
2373 (see MFCosmics::ReadEnv)
2374
2375 - callisto: changed default for fgOffsetFromLogain back
2376 from -2.8 to -1.8 in digital filter.
2377
2378 - callisto: for the common extractors
2379 + MExtractFixedWindow
2380 * MExtractTimeAndChargeSlidingWindow
2381 * MExtractTimeAndChargeSpline
2382 * MExtractTimeAndChargeDigitalFilter
2383 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2384 and fResolutionPerPheLoGain
2385
2386 - callisto: Updated the hi-/lo-gain intercalibration constants
2387 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2388 hilocalib_df6.root
2389
2390 - callisto: The default lo-gain extraction window for the
2391 MExtractTimeAndChargeSlidingWindow extractor has been increased
2392 from 6 to 8 to take the stretch of the pusle into account
2393
2394 - callisto (!!!): fixed an important bug in the setting of the
2395 incoming pedestal pointer to the signal extractor extracting
2396 pedestals. This bug caused the pedestals not to be subtracted
2397 correctly in the calibration afterwards. The effect was about 10%
2398 too high conversion factors for the digital filter and the spline
2399 and more than 40% for the sliding window.
2400 The bug existed since end of February! (Markus G.)
2401
2402 - star: added muon support to star. A new tab "MHMuonPar" is
2403 displayed. The lower right plot is an estimate of the point spread
2404 function. A reference value is displayed. To get the real PSF
2405 you must compare with MC. The setup for the muon analysis
2406 is done in star.rc. More informations can be found in
2407 MHSingleMuon and MHCalibParCalc
2408
2409 - star: The weather data is now displayed in star
2410
2411 - star: MEventRateCalc handles the calculation of the event rate more
2412 accurate now in case of the start of a new run inside a sequence
2413
2414 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2415 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2416 changed only minimally
2417
2418 - ganymed: (MJCut and MJOptimize) now displayes the number of
2419 excess events versus size. The energy estimation is done in
2420 MJSpectrum (sponde)
2421
2422 - ganymed: got support for using other variables than Alpha, eg. Theta.
2423 Therefor you need a class deriving from MHAlpha which supports
2424 this variable (one is already existing: MHTheta, which is now the
2425 default in ganymed). It is setup through ganymed.rc
2426
2427 - added a full featured spectrum program (sponde) which reads
2428 ganymed output and monte carlos and compiles a spectrum
2429
2430
2431
2432 *** Version 0.9.1 (2005/04/14)
2433
2434 - Fix bug on the arrival time reconstruction when using Digital
2435 Filter (in some marginal cases (10%) times were reconstructed shifted
2436 by 0.2 slices)
2437
2438 - all executables now return 2 where in previous versions -1 has
2439 been returned (gave problems with shell-scripts)
2440
2441 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2442 also done with a intercalibration input file
2443
2444 - a bug in the time fine adjustment of the digital filter has been fixed
2445
2446 - a lot of small fixes to calling TPad::Divide with a margin==0
2447
2448 - MStatusDisplay now shows the memory usage
2449
2450 - added a memory leak statistic after the eventloop
2451
2452 - MHadronness replaced by MParameterD
2453
2454 - MEnergyEst replaced by MParameterD
2455
2456 - wobble mode can now be switched on from the data-set
2457
2458 - switched on bad pixel detection for a pedestal level
2459 which is more than 5 times the variance
2460
2461 - Fixed default paths to be correct for the new data center
2462
2463 - Fixed handling of drive data. The pointing position in now
2464 copied to MPointingPos inside star for real and MC events
2465
2466 - made sure, that the sequences in a dataset are sorted by
2467 their number to ensure the correct synchronization
2468
2469 - added all resource files necessary to handle spline extraction
2470 of signal for the late 2004 and the early 2005 data
2471
2472 - update the reference lines for the december data
2473
2474 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2475 This is important for the Dec. and Jan. data where the calibration
2476 pulse position changes much.
2477
2478 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2479 filter. This corrects only an defective extraction of the MC at
2480 low-gain signals lower than 90 phes.
2481
2482 - fixed some slowdown in calibrating data with interleaved events from
2483 Jan and Dec. As a workaround made the pretty palette the default.
2484 The inverse Deep Blue Sea has a bug which slows down long calibration
2485 runs a lot.
2486
2487 - implemented new values from new starguider report as defined
2488 in TDAS00-07 V7.1 (eg SkyBrighness)
2489
2490 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2491 in starguider report (If you merpp the same reports with this version
2492 you'll get the correct units (arcmin) but a different result
2493 than with old versions (wrong units))
2494
2495 - Now the status display can also write PNG, JPEG and XPM (other file
2496 formats are still unsupported by root)
2497
2498 - added a lot of scripts and macros in directory datacenter used
2499 for automatic processing
2500
2501
2502
2503 *** Version 0.9 (2005/03/23)
2504
2505 - Calibration is now done autmatically into photo-electrons like
2506 decided by the Collaboration Board
2507
2508 - Reference lines in the display can be read from resource file
2509
2510 - Interlaced calibration events can be handled by callisto
2511
2512 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2513 and applied in callisto.
2514
2515 - class MJCalibTest can be called by callisto
2516
2517 - callisto can now run with three data types: rawdata, rootdata, MC
2518
2519 - added two classes mreport/MReportStarguider.cc and
2520 mreport/MReportStarguider.h for implementing starguider-data
2521
2522 - the output of merpp-update now contains starguider information:
2523 MReportStarguider and MTimeStarguider
2524
2525 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2526 values were lower than they should. This was more visible for high
2527 energy (Size) events.
2528
2529 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2530
2531 - added a new loop to callisto to support the correct extraction of
2532 the pedestal and pedestal rms through the signal extractor
2533
2534 - added class to perform fourier tranformation of a hexagonal structure
2535 (MHexagonalFT)
2536
2537 - added class to perform fourier tranformation of a hexagonal structure
2538 in a tasklist (MHexagonalFTCalc) example: hft.C
2539
2540 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2541 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2542 small pixels, example: extendcam.C
2543
2544 - added possibility to write data to memory (TTree) using MWriteRootFile
2545
2546 - added possibility to read a TTree stored only in memory by MReadTree
2547
2548 - new classes to deal with the interleaved calibration events:
2549 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2550
2551 - implemented filters to callisto to skip calibration events
2552
2553 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2554 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2555 the slices by statistics
2556 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2557 signal extractor without randomization
2558 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2559 with the signal extractor with randomization (extraction window is
2560 randomly fixed)
2561 The three kind of pedestal is not yet implemented (for speed reasons) as
2562 long as nobody really needs it:
2563 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2564 extracted with the signal extractor with randomization
2565
2566 - callisto now finds the pulse position in the data automatically
2567
2568 - implemented data reduction in calibrated data by reducing the precision
2569 of the stored floating point values (pedestal, rms and signal) to
2570 roughly 0.5%
2571
2572 - fixed showplot to make file format conversion (eg. converting a
2573 status display stored in a root file into a postscript file) in
2574 batch mode possible:
2575 showplot -b --save-as-ps[=outfile.ps] infile.root
2576
2577 - Allow class names as part of filter rules, eg
2578 (MFSupercuts) && (MHillas.fSize>100)
2579
2580 - fixed a lot of stuff to allow all programs to process MonteCarlo
2581 camera files.
2582
2583 - enhanced possibility to debug reading of resource file
2584
2585 - MDataChain should handle priorities of operator more
2586 accurate now
2587
2588 - completely revised the container in which the signal is stored
2589 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2590 * the new implementation is faster and
2591 * needs less storage space
2592
2593 - FIRST version which can process Monte Carlos through the
2594 whole chain of programs (callisto, star, etc)
2595
2596 - implemented new image parameters for the border length of
2597 the shower image (MNewImagePar2)
2598
2599 - implemented wobble-mode in ganymed
2600
2601 - new class (MJOptimize) taking care of all optimization processes
2602
2603
2604
2605 *** Version 0.8.6 (2004/10/05)
2606
2607 - New combined signal and time extractor
2608 MExtractTimeAndChargeDigitalFilter
2609
2610 - The Report for the trigger section in the CC run summary has been
2611 updated, and now the IPRs (Individual Pixel Rates) are available.
2612
2613 - new macros for database interaction: filldotrun.C, filldotrbk.C
2614
2615 - added new program which can convert colored output which was redirected
2616 into a file back into colored text (for example to display it with
2617 more): showlog
2618
2619 - added new program to display an MStatusArray of plots (stored with
2620 MStatusDisplay) from a file: showplot
2621
2622 - Added support for Sequences (MSequence). Sequences are blocks of run
2623 files containing the same calibration and belonging to the same
2624 source
2625
2626 - Added a new task (MTaskEnv) which can be used in setup files to switch
2627 between different tasks (for example to choose a signal extractor)
2628
2629 - Implemented automatic file splitting in MWriteRootFile
2630
2631 - After image cleaning an island index is assigned to all used pixels.
2632 The index corresponds to the order of the islands in size.
2633
2634 - added a cleaning which takes signal height _and_ arrival time into
2635 account: probability cleaning (for more details see MImgCleanStd)
2636
2637 - added a cleaning which takes takes the absolute number of photons
2638 times the area ratio as cleaning level
2639 (for more details see MImgCleanStd)
2640
2641 - Changed calculation of image parameters such, that it can be done
2642 for all used pixels or the pixels with a defined island index only
2643
2644 - implemented new image parameters displaying the number of islands,
2645 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2646
2647 - event display in executable changed to support also calibrated files
2648 (done with MJCalibrateSignal)
2649
2650 - added program doing the calibration and the signal extraction
2651 and signal calibration: callisto Most part of the setup is done
2652 by a resource file: callisto.rc
2653
2654 - implemented support for pixels with negative IDs (Raw file format
2655 version 4)
2656
2657 - implemented an new option in merpp (--auto-time) to get the time
2658 range for cc and/or caco data from the run header of the raw data
2659
2660 - New star-program (star and MJStar). Taking calibrated data from
2661 callisto/MJCalibrateSignal as input. The setup is done through
2662 a resource file: star.rc
2663
2664 - Added possibility to setup the eventloop in the mars-executable
2665 Camera Display by a resource file: mars.rc
2666
2667 - The the mars-executable Camera Display can now also read
2668 calibrated data files written by callisto/MJCalibrateSignal
2669
2670 - Added a new class which can calculate the source position in
2671 the camera from a pointing model known to be correct and
2672 the pointing model used for observations (MSrcPosFromModel)
2673
2674 - added a new version of the class calculating the effective on-time
2675 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2676 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2677 MHTimeDiffTheta.
2678
2679 - added the possibility to count how often a signal is above (or
2680 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2681 can replace MHTriggerLvl0)
2682
2683 - added ore convinient ways to set the axis-titles of your histograms
2684 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2685 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2686
2687
2688
2689 *** Version 0.8.5 (2004/08/06)
2690
2691 - new Signal Extractors: MExtractFixedWindowSpline
2692 and MExtractAmplitudeSpline
2693
2694 - implementes interleave in merpp to be able to merpp parts of a file
2695
2696 - implemented force-functionality to merpp
2697
2698 - star display to display star catalogs (MAstroCatalog)
2699
2700 - star display to 'mirror' stars to the camera (MAstroCamera)
2701
2702 - implemented a new cleaning option which allows cleaning scaled with
2703 the real ratio of the rms depending on the pixel size, not only the
2704 square root of the pixelsize (MImgCleanStd, MCameraData)
2705
2706 - removed obsolete MBlind* classes
2707
2708 - Signal extractor taking the AB flag into account implemented (this makes
2709 an odd number of slices for signal extraction possible
2710 (MExtractSignalABcorr)
2711
2712 - implemented a class extracting the pedestal from the raw-data (events)
2713 itself using empty lo-gain (MpedCalcFromLoGain)
2714
2715 - Added mean values to MPedPhotCam
2716
2717 - Added Makefile for Darwin (this OS is NOT officially supported!)
2718
2719
2720
2721 *** Version 0.8.4 (2004/04/19)
2722
2723 - new fast arrival time extractor using cubic splines:
2724 MExtractTimeFastSpline
2725
2726 - implementes multi-argument support in MDataChain
2727 ("pow(a, b)")
2728
2729 - implemented double reference support in MDataChain
2730 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2731
2732 - added support in MF for expressiond like
2733 "MHillas.fWidth<2*<MHillas.fLength"
2734
2735 - MDataChain is now able to support variables like [0], [1], ...
2736 which can be used in fit functions as parameters. The interface
2737 is implemented through the new virtual function
2738 MParContainer::SetVariables
2739
2740 - added new class MArrivalTimeCam/MArrivalTimePix:
2741 Storage containers to hold the ArrivalTime of the camera/pixel
2742
2743 - added new classes for the calibration of relative arrival times:
2744 MCalibrationRelTimePix and MCalibrationRelTimeCam
2745
2746 - added new classes to extract the signal of the blind pixel and the
2747 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2748
2749 - added new classes for the bad-pixels treatment (MBadPixels*)
2750 which are more powerfull than the old ones (MBlindPixel*)
2751 and will replace them.
2752
2753 - added filter against cosmics: MFCosmics
2754
2755 - added new class MArrivalTimeCalc2:
2756 Calculates the arrival time as the signal weighted mean of the time
2757 slices in the maximum window
2758
2759 - added a new macro call pointspreadfucntion.C that fits with a 2D
2760 gaussian the DC spot for an star. It gives you the RMS of
2761 the PSF and the center of the star, very useful for misspointing
2762 studies.
2763
2764 - added support for multi-telescope camera files. Added classes
2765 MStereoCalc and MStereoPar, classes to calculate and store shower
2766 parameters calculated from the data of two telescopes, for the MC
2767 studies regarding the MAGIC clone.
2768
2769 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2770 MC data calibrated in photons instead of ADC counts.
2771
2772 - added three macros to show the calibration and analysis chain of
2773 MC data. The macro starmc.C does both calibration and analysis, producing
2774 an output containing Hillas parameters for each event. The macro
2775 mccalibrate.C does just the calibration and writes out a file containing
2776 pixel information in photons instead of FADC data. The macro starmc2.C
2777 reads in such a file and produces an output with Hillas parameters.
2778
2779 - added MPedPhotCalc to compute pedestals in units of photons, see
2780 macro pedphotcalc.C
2781
2782 - added all class to perform the calibration, see macro calibration.C
2783
2784 - added class MFFT to perform Fast Fourier Transforms
2785
2786 - added class MSimulatedAnnealing to perform simulated annealing
2787 minimizations
2788
2789 - added new macro bootcampstandardanalysis.C which holds the skeleton
2790 of the analysis chain discussed in the december bootcamp.
2791
2792 - added support for DAQ raw data file format V2
2793
2794 - implemented an arbitrary time stamp for the events from raw-data
2795 files with file version<3. It is calculated from the run number,
2796 the date of start and the FADC clock tick from the first module
2797
2798 - implemented the correct decoding of the event time-stamp
2799 coming from the DAQ for raw-data files with file-version>2
2800
2801 - added a new classes storing the pedestals in units of photons:
2802 MPedPhotPix, MPedPhotCam
2803
2804 - added support for DC current files from the camera control
2805
2806 - added support for start- and stop-time when merpping report files
2807
2808 - added MReportCC storing the weather data from the CC-REPORT
2809
2810 - added class to fill trainings and test matrices (MTFillMatrix)
2811
2812 - added a filter performing a software trigger (MFSoftwareTrigger)
2813
2814 - Added classes to perform parts of the standard analysis (Jobs):
2815 + MJPedestals
2816 + MJCalibration
2817 + MJExtractSignal
2818 Note: All of them are preliminary!
2819
2820 - Added Iterator to iterate over files giving only the run-number
2821
2822 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2823 the evolution of a sector vs time
2824
2825
2826
2827 *** Version 0.8.3 (2003/12/05)
2828
2829 - adapted Random Forest classes to allow the use with MC
2830 multi-telescope files which can be produced with the coming
2831 camera version 0.7.
2832
2833 - added classes to read and interprete central control report files
2834 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2835
2836 - enhanced merpp (the executable) to support .raw and .rep files.
2837
2838 - added classes for light calibration (MCalibration* and
2839 MHCalibration*) by Markus Gaug. Further work has to be and will
2840 be done soon.
2841
2842 - Added a preliminary 'synchronizer' (MReadReports) which will
2843 replace MReadMarsFile as soon as it is finished.
2844
2845 - Added a tutorial macro demonstrating how report files are merpped
2846 and how they can be read from the root file in the correct order
2847 of time (readrep.C)
2848
2849 - Added a generalized histogram (similar to MH3) called MVsTime
2850 which allows to plot variables (or rules - MDataChain - of
2851 variables) vs time. For an example have a look at tempvstime.C.
2852
2853 - Changed the name of the event trees:
2854 + Events --> Events
2855 + PedEvents --> Pedestals
2856 + CalEvents --> Calibration
2857
2858 - changed name of MTime in the event trees from MRawEvtTime to MTime
2859
2860 - added displaying the sector indices to the mars event display
2861
2862 - Magic Online Analysis (MOnA) implemented in a first version
2863 (see mona.cc, MOnlineDump and MOnlineDisplay)
2864
2865 - added classes to calculate event rate
2866 (preliminary: MEventRateCalc, MEventRate)
2867
2868 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2869
2870 - added classes dealing with the telescope pointing position (MPointing*)
2871
2872 - implemented the 'final' Mars time stamp based on some experiences with
2873 the new 'Synchonizer'
2874
2875
2876
2877 *** Version 0.8.2 (2003/11/10)
2878
2879 - accelerated standard analysis by a factor of 6-8 ...
2880 + doing precalculations in MGeomCam for the pixel area ratio
2881 + creating a look up table for the single pixels in MCerPhotEvt
2882
2883 - added task to calculates weights in case you want to 'change'
2884 the energy spectrum of a monte carlo file
2885 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2886
2887 - added a new executable star which implements the
2888 star.C macro as precompiled executable. Currently a flexible
2889 setup is not possible, but a 'input card' setup will follow.
2890
2891 - Starting to implement Multi-Telescope-Support based on the
2892 upcomming camera version 0.7. The base for a general support
2893 is implemented and the star-functionality is proven to work.
2894
2895 - Replaced Event-Display in and Camera-Display in the Mars GUI
2896 executable by a more convinient display base on MStatusDisplay.
2897
2898 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2899
2900
2901
2902 *** Version 0.8.1 (2003/10/20)
2903
2904 - added signal subtraction for pure on data by means of fitting
2905 the background in the off region or by performing a combined
2906 signal/background fit. Provides necessary histograms for
2907 obtaining energy spectra and a light curve.
2908
2909 - added classes to perform and study the selection of the
2910 2nd Level Trigger on MC data (example in triglvl2.C macro)
2911
2912 - added pedestal calculation
2913
2914 - implemented "democratic cleaning" (tail cut value proportional
2915 to pixel area) according to Wolfgang's suggestion.
2916
2917 - added Sigmabar treatment (calculation and basic histogramming)
2918
2919 - added basic routines to apply padding
2920
2921 - added first implementation of MARS-based source visibility plotter
2922 (needs to be linked against slalib, preliminary version)
2923
2924 - enhanced functionality of data chains: random numbers, conversion
2925 functions and access to MHMatrix objects
2926
2927 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2928 numbers under certain circumstances (runs with 0 events included)
2929
2930 - fixed a bug in the general filter MF (didn't work on some systems
2931 at all)
2932
2933 - fixed a bug in chaining files, which caused the analysis to crash or
2934 ignore files
2935
2936 - implemented more geometry classes describing the parameters used
2937 to simulate the PMT camera
2938
2939 - added new Monte Carlo classes containing the setup of the different
2940 programs in the MC chain.
2941
2942 - added a (preliminary) general task to evaluate chi-square of a given
2943 parameter in an eventloop.
2944
2945 - first implementation of a container describing the observatory
2946 location (Long, Lat, etc)
2947
2948 - added Random Forest - method for g/h-separation
2949
2950 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2951 (this means, that it is compiling, but not yet fully tested)
2952
2953 - added a new status display which can show the present status
2954 of histograms while an eventloop is running (MStatusDisplay,
2955 an example can be found at status.C)
2956
2957 - reorganized directories:
2958 classes describing the image --> mimage
2959 classes containing Monte Carlo Histograms --> mhistmc
2960 classes for Random Forest method --> mranforest
2961
2962 - added (event-)weights to fill histograms
2963
2964 - colors in logging output to screen
2965
2966 - changes to the Image Parameter declaration:
2967 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2968 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2969 + MHillasExt now derives from MParContainer instead of MHillas
2970 --> Files written with the old definition are more or less unreadable
2971
2972 - reading of reflector files
2973
2974 - display data from reflector files in the camera
2975
2976 - implemented currents (and display them in the camera)
2977
2978 - logarithmic scale in camera
2979
2980 - added class to iterate through directory contents (MDirIter)
2981
2982
2983
2984 *** Version 0.8 (2002/11/18)
2985
2986 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2987
2988 - corrected 48(!) wrong entries in the Next Neighbor table of the
2989 Magic Camera (all in the inner part of the outer ring, mostly
2990 missing a single NN)
2991
2992 - Fixed a bug in the table describing the Next Neighbours of the
2993 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2994 have any neighbour)
2995
2996 - changed trigrate.C: now it calculates the pure NSB triggers from
2997 a camera file (generated with no showers), so there is no need
2998 to introduce them by hand in the BgR array (for more details
2999 please ask Abelardo)
3000
3001 - added MHHadronness (and MHadronness) as a general facility to evaluate
3002 the quality of a gamma-hadron seperation method
3003
3004 - changed MWriteAsciiFile to accept rules (MDataChain)
3005
3006 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3007 must be replaced by calles to MWriteAsciiFile::AddColumn and
3008 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3009 changed.
3010
3011 - Implemented generalized event-matrices (one row per event)
3012 (MHMatrix)
3013
3014 - implemented the one dimensional composite probabilities
3015 (MHCompProb, MCompProbCalc, comprob.C)
3016
3017 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3018 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3019
3020 - Added a camera display displaying the pixel numbers to the
3021 event display gui.
3022
3023 - Added Monte Carlo Informations to event display gui
3024
3025 - Changed the camera display to display the pixel numbering
3026
3027 - Added three buttons to the camera display to change the palette
3028
3029 - Added the number of used and core pixels after image cleaning
3030 to MHillas
3031
3032 - Changed the algorithm used in MHillas according to TDAS 02-03
3033
3034 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3035
3036 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3037
3038 - Added fCosDeltaAlpha to MHillasSrc
3039
3040 - The numbers of photons used to calculate fConc and fConc1 in
3041 MHillasExt are now scaled with the pixel size, so that one get
3042 a four times smaller value for the bigger pixels in the outer ring.
3043
3044 - added new task to smooth the camera contents (MCameraSmooth)
3045
3046 - added possibility to use interpolated pixel values for blind pixels
3047 instead of removing it completely from the analysis
3048
3049 - Implemented the possibility to save the whole eventloop with
3050 its setup to a file. This information can be read and from
3051 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3052 and MEvtLoop::MakeMacro. If you find something not working, please
3053 report - this stuff is still in a beta phase.
3054
3055 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3056 file having crab starfield, but also for all following files - fixed
3057
3058 - MTaskList::PrintStatistics can now be instructud to print also the
3059 title, too: use PrintStatistics(0, kTRUE)
3060
3061 - Changed the image cleaning so that pixels with to many 'used'
3062 neighbors are left used (to get rid of 'holes' in events)
3063
3064 - Introduced more output to the camera displays
3065
3066 - Added an array of histograms (eg one hist per run), MHArray
3067
3068 - Added a _preliminary_ version of the reader for CT1 PreProc files
3069 (MCT1ReadPreProc)
3070
3071 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3072 (thanks to Raquel)
3073
3074 - added the first energy estimator (MEnergyEstParam, estimate.C,
3075 estfit.C) using a parametrization
3076
3077 - Added some new Monte Carlo paremeter containers used to store
3078 setup information from the MC chain (MMcConfigRunHeader,
3079 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3080
3081
3082
3083 *** Version 0.7 (2002/04/30)
3084
3085 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3086 the pedestal mean value was saved incorrectly. For files from
3087 this versions we substract 0.5 from the pedestal mean.
3088 WARNING: This may effect your results, so don't wonder...
3089
3090 - First implementation of an algorithm using only triggered events
3091 for the collection area calculation
3092
3093 - Ascii Output can now also be used for parameter containers which
3094 doesn't overload MParCointainer::AsciiWrite
3095
3096 - The Ascii Output is now also capable of writing single data members
3097 of one container
3098
3099 - You are now able to change the order of the values written to the
3100 ascii file
3101
3102 - You can now specify a conversion factor for each data member written
3103 to an ascii file. This may be usefull to change the units of the
3104 data member (eg. degrees instead of millimeters in case of the
3105 hillas parameters)
3106
3107 - Replaced old MHillas by a new structure which allows you to extend
3108 the parameters stored in MHillas very easily:
3109 see MHillas and MHillasExt
3110
3111 - Added classes to handle source dependancy of image parameters:
3112 see MHillasSrc
3113
3114 - Added container (MBinning) to have a standard input for the binning
3115 in different histograms (eg. the Energy bins should be the same in
3116 all histograms)
3117
3118 - Changed Hillas histograms from mm to deg
3119
3120 - Added the flexible binning to the hillas histograms
3121
3122 - Added a filter for the alpha parameter (MFAlpha)
3123
3124 - It is now possible to write single data members of a class object to
3125 an output stream instead of the whole container only
3126
3127 - Added a generalized filter for a data member:
3128 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3129
3130 - Added a generalized Filter parser for more difficult filter rules
3131 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3132
3133 - Added new Monte Carlo histograms:
3134 MHMcEnergyImpact and MHMcEfficiency
3135
3136 - Added many new histograms needed for the flux calculation.
3137
3138 - Added a generalized histograms which can fill and show up to three
3139 data members in either a one-, two- or three-dimensional histogram, eg:
3140 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3141
3142 - Added:
3143 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3144 * calculation of <Theta> as a function of time (MHThetabarTime)
3145 they are needed in the flux calculation in
3146 order to select for a given bin in Theta (or time) the appropriate
3147 effective collection area, which is assumed to be given as a function
3148 of Theta and the true energy
3149
3150 - Added calculation of the migration matrix in the energy
3151 (MHMcEnergyMigration):
3152 the migration matrix describes the migration from the true (E_true)
3153 to the estimated energy (E_est); it is needed to determine the
3154 distribution of E_true from the measured distribution of E_est
3155 by unfolding
3156
3157 - changed the color palette in the camera display to DeapSea.
3158
3159
3160
3161 *** Version 0.6 (2002/01/15)
3162
3163 - Introduce the option of disable pixels (MBlindPixels and
3164 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3165 able to deal with Star Field NSB.
3166
3167 - Fixed a bug in the pedestals substraction
3168
3169 - Introduced verbosity levels
3170
3171 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3172
3173 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3174 work correctly (thanks to Abelardo)
3175
3176 - Introduced correct treatment of the diffuse Night Sky Background
3177 and NSB (MMcPedestalNSB)
3178
3179 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3180
3181 - Introduced MMcRunHeaders which contains monte carlo run informations
3182
3183 - Added a 'Print'-Task (MPrint) which calls the Print function
3184 of a parameter container for each event
3185
3186 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3187
3188 - changes to be more efficient with root 3.02/06
3189
3190 - root 3.02/06 fixes:
3191 + the memory leak when reading MRawEvtData
3192 + loosing more time than necessary to update the progress bar
3193
3194 - MWriteAsciiFile is now capable of writing more than one container
3195 in a line. For example: To be able to write Monte Carlo and
3196 Hillas values (energy and alpha) in one line.
3197
3198
3199
3200 *** Version 0.5 (2001/11/06)
3201
3202 - Added new GUI functionality (Analysis)
3203
3204 - Added a camera display to be able to display events in the camera
3205 together with the calculated hillas ellipse
3206
3207 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3208 object at any state of the analysis, so that the output are several
3209 states
3210
3211 - Fixed a bug in the collection area error calculation
3212 (Thanks to Ciro and Abelardo)
3213
3214 - Fixed a bug which causes merpp to crash in some environments
3215
3216 - Implemented auto enabling scheme for Branches to speed up reading
3217 a lot (see MReadTree and MTask)
3218
3219 - Fixed a bug in the Histogram classes which caused histograms to
3220 be written to a file by MWriteRootFile without request
3221
3222 - changed the object I/O from the old stylish root I/O to the new
3223 'auto evolution scheme' This was done only for classes which are not
3224 yet used in Monte Carlo files, so that these files are still readable.
3225
3226 - Added support for a progress bar in MEvtLoop and MReadTree
3227 (see the Analysis Window in Mars for an example)
3228
3229 - Fixed a bug in the package creation which disturbed the conversion
3230 between a mars version unpacked from a tar file and the repository.
3231
3232 - Changed the code to writer merpped (converted into root format)
3233 raw files, to get faster (around 10%)
3234
3235
3236
3237 *** Version 0.4 (2001/09/20)
3238
3239 - This release is made to compile on a root version >= 3.00
3240
3241 - Fixed a bug which causes MReadTree to read the first file only
3242
3243 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3244
3245 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3246
3247 - Added a task to write several container to a root file (MWriteRootFile)
3248
3249 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3250
3251 - Added calculation of the collection area (MMcCollectionAreaCalc)
3252
3253 - fixed some bugs in the Hillas calculation
3254
3255 - added filters to be able to control the task execution dependent on
3256 a parameter (for example: the number of level 1 triggers in a MC-file)
3257
3258
3259
3260 *** Version 0.3 (2001/04/23)
3261
3262 - Many demo macros added
3263
3264 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3265
3266 - Hillas Calculation added
3267
3268 - Standard image cleaning available
3269
3270 - MReadTree is now able to handle more than one file
3271 (Remark: of the same structure)
3272
3273 - Now we are able to display events in a first version of the
3274 Camera event display. To do this we must run the macro
3275 "macros/readCT1.C" to read data from CT1.
3276
3277
3278
3279 *** Version 0.2 (2001/01/24)
3280
3281 - First Implementation of a Gui to read the raw data. Start the
3282 gui with the command mars.
3283
3284
3285
3286 *** Version 0.1 (2000/12/20)
3287
3288 - First official release 0.1
3289
3290 - Changes:
3291
3292 + changed calling style of MRawPixelIterator from do...while to
3293 while-loop
Note: See TracBrowser for help on using the repository browser.