source: trunk/MagicSoft/Mars/NEWS@ 9433

Last change on this file since 9433 was 9433, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 133.3 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 * Added consistency check for two consecutive runs
11
12 ;showplot:
13
14 * If a file without a MStatusArray is opened all object (not just
15 canvases) found in the file are drawn. Note that this may result
16 in empty tabs.
17
18 ;ceres:
19
20 * The night sky noise is now scaled with the sensitive area and
21 is given in units per square centimeter
22
23 * Added the possibility to add a cut after the image parameter
24 calculation (''Cut'')
25
26 * updated the PDE of the GAPDs with a more reliable curve from
27 the meeting page (linear extrapolate below 350nm)
28
29 * The impact distribution in the event distrbutions is now
30 perpendicular to Alt/Az and the histogram is displayed in 1D
31
32 * The GAPD PDE has been updated
33
34 * PDEs and mirror reflectivities have been linearily extrapolated
35 to match the wavelegth range between 290nm and 900nm
36
37 * There is no default pulse shape anymoe it must be given in
38 the resource file
39
40 * Fixed a bug which caused the aerosol coefficient to be incorrectly
41 initialized. The effect might be random but seems to be small.
42
43 ;callisto:
44
45 * Fixed a bug which prevented MAGIC Monte Carlo file from being
46 calibrated (ceres files worked)
47
48 ;ganymed:
49
50 * added new starguider calibration for sequences since 1000534
51
52
53
54== Version 2.3 (2009/03/07) ==
55
56 ;SUGGESTION
57
58 * There is no need to re-run any data because no change took place which
59 could have an effect on the output. However, if you want a
60 meaningful SrcPos plot for your MCs in sponde you must re-process
61 star for your MCs first.
62
63 ;REMARK
64
65 * File produced with this release containing a camera geometry (which
66 are basically all files were produced as default) will not be readable
67 by older releases.
68
69 ;general
70
71 * fixed a few small bugs which could cause the display to crash in ganymed
72 and sponde
73
74 * in sequence file the date can now be omittet. In this case the
75 leading date with the underscore is missing in the expected filename
76
77 * the geometry class now also supports other geometries than just hexagons
78
79 ;automation
80
81 * added magnetic field Azimuth direction (ARRANG), currently
82 at ~ -7deg at La Palma
83
84 ;database
85
86 * plotdb.php: added default (sequences) for startup, added possibility
87 to set size of plot
88
89 * added a new table ''RunDataCheck'' which containes the rates after
90 image cleaning for every run which succeeded star. It can be
91 plotted using ''plotrundb.C''
92
93 ;merpp
94
95 * added support for Arehucas Version >= 200812140
96
97 * added support for Arehucas Version >= 200809030
98
99 ;mars
100
101 * The display now also displays the trigger pattern
102
103 * The display can now display ceres reflector (_R_) files
104
105 ;ceres
106
107 * added a uniformly distributed one-bin time jitter for the start of the
108 digitization. Otherwise the first photon would be digitized always with
109 the same alignment to the bins
110
111 * Added a plot showing the production height of the photons
112
113 * Moved the particle id from the event header to the run header
114
115 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
116
117 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
118
119 * Added many new options to control the tasks. For deatils see ''ceres.rc''
120
121 * Removed obsolete plots in pedestal and calibration mode
122
123 * Removed the non-NightSky photons from the plots where they are just
124 disturbing
125
126 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
127
128 * The daq event number now represents the readout number
129
130 * The camera ''electronics'' can now be ''switched off''
131
132 * A new tab ''Info'' now display basic things like the reflector
133 layout
134
135 * Improved reading speed for corsika files
136
137 * Improved memory handling (if a large ampount of memory was needed
138 for a single event all further events were stored in the same
139 memory and it was never freed, so the program took this memory
140 until the end)
141
142 * Converted the code from MMCS' reflector program to MSimAtmosphere
143 (instead of the tables build in for MAGIC Winter and Summer
144 atmosphere we use the values written by Corsika fitted to the
145 tabulated atmosphere given as input)
146
147 * For caluclating the displayed image parameters in ceres a basic
148 image cleaning removing isolated pixels is now done.
149
150 * The magnetic field direction (ARRANG) is now taken into account
151
152 * Added plot for the energy threshold after trigger ''Threshold''
153
154 * Added plot for the effective collection area after trigger ''TrigArea''
155
156 ;star
157
158 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
159
160 * The definition of fConcCore has slightly changed. The numbers
161 might decrease a little bit (the effect should be rather small)
162
163 ;ganymed
164
165 * added pointing model 328198
166
167 ;sponde
168
169 * The SrcPos plot for your MCs was so far meaningless because it just
170 displayes the MSrcPosCam data from the input star-files. Unfortunately,
171 this containes was never written to the star-files yet.
172
173 * A new Tab 'OnTime' is available which is an effective on-time
174 fit as in star but for all data. This is mainly for manual cross-check
175 of the effective on-time
176
177 * In some circumstances it might be necessary to re-calculate the
178 eff. on-time from the fit in the new tab, e.g. when a zenith distance
179 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
180
181 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
182 it to its own output file (for convinience)
183
184
185
186== Version 2.2 (2009/01/30) ==
187
188 ;SUGGESTION
189
190 * This release doesn't contain a major change which is expected to
191 change your results. Nevertheless there are small changes to
192 the calibration which can effect at least the first few hundred
193 events in any (mainly MUX and even more SUM) sequence a little bit.
194 So it is recommended although not necessary to reset your sequences
195 in the database before further processing.
196
197 ;NEW
198
199 * A first implementation of a Monte Carlo simulation program
200 (ceres - Camera Electronics and REflector Simulation) has been
201 implemented. It can simulate a full telescope already including
202 a complete reflector simulation and a flexible trigger and readout
203 simulation. Currently, no perfect setup is implemented and
204 especially the output of the program (data structure) should
205 be considered alpha state. Also the user interface is not yet
206 ready.
207
208 ;general
209
210 * All command line options after -- are now interpreted as
211 arguments (usually everything which doesn't start with a minus)
212 rather than options (usually everything which starts with a
213 minus). This allows to use file names starting with a -
214
215 * In all resource files you can now initialize the random number
216 generator. For details see: MJob::InitRandomNumberGenerator
217
218 * added a new program called ''readcorsika''. It's purpose is (in analogy
219 to readraw and readdaq) to read a Corsika output file (for now
220 only cherenkov output is supported) and print its contents in a
221 human readable form. It can also write the contents of this file
222 into a root-file.
223
224 * The calculation of the maximum distance to the origin in a MGeomCam
225 has been improved (edges might be further away than the sides).
226 This is just a tiny change but it might change the appearance of
227 the radial profiles a little bit.
228
229 * The default binning of the center-of-gravity plot has slightly been
230 increased
231
232 ;Database
233
234 * Added informations about the DC currents (fMinCurrents, fMedCurrents
235 and fMaxCurrents). The values are retrieved from the plots showing
236 the average DC currents of all pixels versus time.
237
238 * Websites with tables have now the opportunity to remove lines
239 ('-' button at beginning of each line) and get all lines back
240 ('+' at top of the column)
241
242 * Websites: added option to query only sequences containing sumtrigger
243 events
244
245 * Websites: added option to group by date (year, month, night) for runs
246 and sequences and enabled that combining of different group-bys,
247 e.g. status, date and source is possible
248
249 ;automatic analyis
250
251 * Rewritten producing plots in the web.
252 New plots, namely the output of plotoptical.C (extinction curve from
253 KVA), plotstat.C (status of the automatic analysis (percentage of
254 processed, analysed data etc.)) and plotusage.C (statistics of the
255 condor usage in the data center) has been are available now next to the
256 plots of plotdb.C
257 Mean values from the plots (output of the macro) are provided in a
258 txt file now.
259 The creation of the plots for callisto, star and ganymed in the web is
260 now steered via database. Consequently the plots are faster and
261 reliable up-to-date.
262 For all plots, a new layout is available facilitating the browsing
263 through the plots and providing additional information on the
264 displayed values. (tabs.php) These plots are linked from the DB
265 websites and the wiki.
266
267 ;statusdisplay
268
269 * The ''Loop'' entry in the menu bar now contains an option to pause
270 the loop and to process single events.
271
272 ;merpp
273
274 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
275 instead of RunHeaders)
276
277 * Now allows to merpp files newer than 2008/09/03.
278
279 * Added fixes for wrong (wrong or double) run- and file-numbers
280 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
281
282 ;callisto
283
284 * Extracting the pulse position for the pulse position check events
285 with sum trigger were denied. This decreased the statistics
286 extremely and therefor the resulting puse position was calculated
287 quite weak. Now sum events pass the calculation if and only if they
288 have also a level 1 trigger.
289
290 * the extraction of pedestal events and pulse position from the
291 first data events is now more automatic and makes sure that
292 a more precise number of events is extracted independent of
293 the ratio with which pedestal events or events with signals
294 are contained in the data.
295
296 * Updated Muon calibration constants for all MUX data (teh changes were
297 all smaller than 5%)
298
299 ;star
300
301 * For the calculation of the effective on time all sum-triggered events
302 were skipped. Now all Level1-triggeres events will pass. This might
303 result in a slight inaccuracy of the effective on time.
304
305 ;ganymed
306
307 * If the source position is more than 1deg away from the camera
308 center an error is raised now.
309
310 * Hopefully fixed the bug ''ganymed crashes when resized''
311
312 ;sponde
313
314 * Fixed a problem which causes the fitted spectral slope to be displayed
315 incorrectly. If you use MJSpectrum::FormFlux in your macros make
316 sure that the parameter 0 of your fit is negative.
317
318 * Added a histogram showing the read source position of your MCs
319
320
321
322== Version 2.1.1 (2008/08/04) ==
323
324 ;Database
325
326 * Added the median number of photo electrons from the calibration
327 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
328 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
329
330 * Added fTotOnTime, which is the on-time as given by the run-headers
331 (in contradiction to fAbsOnTime which comes from CC)
332
333 * Added new primaries for the new data structure (Magic II): for the
334 tables dealing with sequences (SequenceBuild Status, Sequences,
335 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
336 this is the telescope number (fTelescopeNumber) for the tables dealing
337 with runs (RunData and RunProcessStatus) this is in addition the file
338 number (fFileNumber)
339
340 * Added column fPriority to the status tables to be able to steer the order
341 in which the data is processed. As default the run, sequence and dataset
342 number are used.
343
344 ;automatic analyis
345
346 * Adapted scripts to the new data structure: They can handle now different
347 telescopes (getting the information as usual from the database).
348 The paths for Magic 2 are not yet implemented.
349
350 ;general
351
352 * should work now with root 5.20/00 (please note that root 5.20/00
353 we encounter crahses in the status display which are ot yet
354 understood)
355
356 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
357 instead of the base name of the file. This makes them easier to
358 access from the code
359
360 * Default Monte Carlo names in MSequence do not require the _E at
361 the end anymore
362
363 * where abrrevating a sequence file with a sequence number is possible
364 also "telescope:sequence" is now accepted, e.g.:
365 star 2:2000123 --out=output
366 see the programs' help for more details.
367
368 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
369 from the database. See the constructors for more details.
370
371 * MReadTree now supports friends
372
373 * MReadTree can now read also files not written by MARS and store
374 the data encapsulated in emulated MParContainers
375
376 * added a new starguider calibration valid since 15.1.08
377
378 ;showplot
379
380 * showplot can now read more than one file at once. This is especially
381 inetersting if reading files containing pure canvases
382
383 ;merpp
384
385 * we merpp the dc currents now also from the camera reports (they have
386 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
387
388 * In the automatic analysis we omit merpping of the currents from the
389 caco files and use the lower rate camera reports from the cc files
390 instead
391
392 * merpp has been redisigned to allow merpping of the cc-reports
393 of a whole sequence. This allows to design a very simple analysis:
394 mkdir output
395 ./callisto 100776 --out=output
396 ./merpp 100776 output
397 ./star 100776 --ind=output --out=output
398 Instead of the sequence number also sequence files are accepted.
399
400 * Implemented a fix for run-numbers between 1001348 and 1001396
401 which were incorrectly assigned by the cc.
402
403
404 ;callisto
405
406 * added a filter again which was was removed in the last release.
407 it removed the most brightest events. This should not change
408 any analysis result because these events are so bright that
409 they cannot be analysed anyway, but the bad-pixel plots doesn't
410 show outliers.
411
412 * updated muon calibration constants for the periods 51-57,
413 58-63 and 67-
414
415 ;star
416
417 * The camera currents are now displayed with the rate of the camera
418 reports instead of the caco reports
419
420 ;ganymed
421
422 * if mc camera files are new enough (>=8) the source position in the
423 camera is now calculated from the stored telscope and shower
424 orientation (Note, that this might not be suitable in all cases
425 depending on the aim of the study. These case still needs
426 implementation)
427
428
429
430== Version 2.1 (2008/06/18) ==
431
432 ;Database
433
434 * introduced average temperature and wind speed from star-files
435
436 * introduced average values from Pyrometer (mainly Cloudiness)
437
438 * introduced the ratio of accepted calibration events in the
439 calibration run
440
441 * introduced the average rates of the different trigger pattern,
442 e.g. the rate of pedestal and calibration events, from the signal-file
443
444 ;general
445
446 * fixed GroupBy options in plot*.C macros
447
448 * only display KVA points (not the Tuorla points) in plotoptical.C
449
450 * all programs now allow to add resources to the ones from the resource
451 file or overwrite them from the command line. This can be done like this
452 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
453 if something seems to be wrong you can debug what the program is doing
454 using the option --debug-env=3
455
456 * increased the diversity of debug levels. That also means that with -v3
457 you get now less output, i.e. only the output which is important for
458 an analysis. To get more output which helps for debugging try 4, 5 and 6.
459
460 * fixed a problem in the task synchronizing the reading of the reports
461 and the data stream. The effect was that in some circumstances the last
462 events of some trees could have been skipped. Since this is only a
463 very tiny part of the data no severe effect to your analysis results
464 is expected (an exception might be very short, i.e. singel runs,
465 datasets).
466
467 * Dataset file now allow to include the sequence file directly within
468 the dataset file and also allow to exclude single runs from the dataset.
469 (for more details see Class reference of MDataSet)
470
471 * Sequence files now allow for excluding runs from the analysis
472 (for more details see Class reference of MSequence)
473
474 * added code to process the sum-trigger flag
475
476 * the histogram classes MH3 and MHn now support profile histograms
477
478 * the histogram classes MH3 and MHn now support labels at the axis
479
480 * the Random Forest Train-classes (MJTRain*) now store the used datasets
481 in the output file
482
483 * the MFMagicCuts have a new option to allow a linear area cut (for
484 special studies)
485
486 * The liniking of the shared object is now done into a file defined
487 by 'mktemp'. This should be a local file system which accelerates
488 liniking a lot.
489
490 * The code has been prepared for compilation with root 5.18/00d
491
492 * The MHEnergyEst histogram now shows the distribution of
493 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
494 and (Eest-Emc)/Emc vs Emc.
495
496 * fixed mars (event display) for merpped raw-data and MC data
497
498 * adapted the synatx of sequence files to allow for the new run/file
499 scheme. For more details see class description of MSequence
500
501 ;showplot
502
503 * Added support for tiff files
504
505 * Added support for csv files (tables containing tab number,
506 name and title)
507
508 * Tabs now can have a title which is displayed in the postscript file
509
510 * When multiple file are written at once (e.g. pngs from a display)
511 it is now possible to use the tab name and or tab number in the
512 file name. For details see showplos's help.
513
514 ;merpp
515
516 * Implemented cc file version 2008-02-20/0
517
518 * Implemented cc file version 2008-05-19/0
519
520 * With new options merpping can be restricted (in addition to the
521 run-number) also by telescope and file number.
522 For details see "merpp --help"
523
524 * Implemented raw data format 11 (the most important change, except
525 from plenty of changes in the format definition, is the addition
526 of the file-number in the header) If nobody makes a mistake this
527 format should have the advantage that it is by definition forward
528 compatible, so old programs will be able to read newer formats.
529
530 * Added Pyrometer information to default output (stored in a new Tree
531 Pyrometer, needs a complete new merpp, i.e. new calibration)
532
533 * Merpping (also update) can now be restricted to one single report.
534 For example:
535 If you want to update an old file with Pyrometer information call
536 merpp --only=Pyrometer --update
537
538 ;callisto
539
540 * in the pedestal processing now at least 50 processed events are
541 required for succeeding.
542
543 * the signal and calib files now contain also the sequence information
544
545 * the two MPedestalCam in the calib file now have proper names
546 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
547
548 * Both pedestal cams now contain the number of events processed
549
550 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
551 i.e. for the extraction of the calibration pulses basically the average
552 over all events of the first slice instead of all slices was used.
553 Since pedestal and calibration constants are continously recalculated
554 this only effected the very first events of every sequence.
555
556 * For the extraction of the position of the maximum sample now the
557 extraction range is set automatically to the extraction window,
558 before the whole accessible range was used.
559
560 * If the number of samples in the events and the number of samples
561 in the run-header disagrees now an error is raised (this can
562 happen in not well simulated Monte Carlo files)
563
564 * In the case of MUX-data pedestal events with the lvl1 trigger flag
565 could survive into the pedestal calculation -- fixed.
566
567 * Tab "TrigPat" added showing the distribution of the trigger pattern
568 as found in the run-files (normalized with the run length)
569
570 * The selection of events from the trigger pattern has been improved.
571 If the trigger pattern is corrupted events won't pass anymore.
572
573 * Added a new command line option --dev-null to suppress output of
574 Y-files (this is useful for test cases)
575
576 * added a new tab "CalPos" showing the arrival time of extracted
577 interleaved calibration events
578
579 ;star
580
581 * the star file now contains also the sequence information
582
583 * Added a new command line option --dev-null to suppress output of
584 I-files (this is useful for test cases)
585
586 * Tab "Rate" added showing the distribution of the trigger pattern
587 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
588 the Y-files (normalized with the run length)
589
590 * The effective on-time calculation doesn't use events with only
591 sum-trigger anymore
592
593 * The data in the MHWeather tab has been reorganized. The never
594 working solar radiation has been removed and the data from
595 the pyrometer (cloudiness, air and sky temperature) is
596 displayed in addition.
597
598 ;ganymed/sponde
599
600 * Now data points are even shown correctly if they have error bars larger
601 than one sigma. Points with null or negative significances are omitted.
602
603 * DrawNicePlot now allows to set a projection range
604
605 * Updates pointing models. One is applied after the implementation
606 of the new LUTS in August, the other one is applied after the
607 next major change of the pointing model in October. Note that
608 these models are preliminary and give wrong results below Zd=65deg
609
610 ;sponde
611
612 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
613
614 * a new option "--force-runtime" is available. In case of very short
615 datasets (for light-curves) which are in the order of a few
616 minutes the calculated effective on-time is not very acurate because
617 it is quantizised in the order of a minute. Therefore you can switch
618 to using the real run-time instead (remakrt: this ignores any
619 dead-time!)
620
621 * a more analytical way is used to "fill" Monte Carlos into regions
622 of impact parameters which have not been simulated because the
623 trigger efficiency is assumed to be 0.
624
625 * estimated sensitivity curves for hi and lo zenith angles are shown
626 scaled to the correct observation time and collection area
627
628 * the Monte Carlo events after cuts are now written to the output file
629 if an output file given
630
631
632
633 *** Version 2.0 (2007/09/03)
634
635 - database: the position used for the pulse pos check was missing
636 in the callisto output and could thus not be filled into the DB.
637 Also the old values seemed not exactly the PulsePos used for
638 teh check.
639
640 - general: Resource file now allow an Include-Resource, i.e. you can
641 read a resource file with default settings, include it in your
642 resource file and overwrite the settings in your file. More than
643 one include file is allowed. Inclusions can be iterative.
644 Include: mydefaults.rc yourdefaults.rc
645 The resources in the first file have higher priority than the
646 second file.
647
648 - general: Now the output files (calib*.root, etc) also contain the
649 resource file (to check it open it in the TBrowser and choose Print()
650 from the context menu)
651
652 - general: Dataset files now allow to overwrite the default path
653 to search for sequence and data files. Note, that the program
654 option and individual resources will overwrite it. For example:
655 SequencePath: /magic/montecarlo/sequences
656 DataPath: /magic/montecarlo/star
657
658 - general: Fixed a problem with variables in MDataPhrase. It seems
659 that only optimdisp (didn't work) was effected.
660
661 - general: Some improvements to the optim and train processing. For
662 example the ststud window now got a proper title.
663
664 - general: The "Status Display: " was removed from the window title
665 within an Eventloop.
666
667 - general: added a new flexible histogram-class (MHn) which can be used
668 for example in testing after optimizations or training to produce
669 user defined histograms.
670
671 - general: The Random Forest now allows attaching an evaluation
672 function which is applied to its output. This allows to train
673 on whatever you like (eg. train on log10(energy), but return
674 energy)
675
676 - general: The Random Forest training of energy (trainenergy.c) and
677 disp (traindisp.C) has been improved by more graphical output to
678 judge the result.
679
680 - general: The training of energy (trainenergy.C) has been improved
681 a lot by training on a different quantity than energy. It gives
682 a result which is highly independant of the source spectrum
683 and shows lower bias than all other options.
684
685 - general: Dataset files are allowed to contain collections of
686 datasets. For more details see the class reference of MDataSet.
687
688 - general: The default WobbleMode in a datset file now (if not
689 overwritten) is "auto", i.e. wobble mode is set if the dataset
690 doesn't contain off-sequences.
691
692 - merpp: Merpp can read file format version 9 now. Please realize
693 that for file format version 9 the extraction range is different
694 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
695 the first and last 15 slices have been removed from all MUX data.
696
697 - mars: Similar to writing movies you can now select events which
698 should be displayed in your display. Therefore add the following
699 lines to your mars.rc:
700 MFEvtNumber.FileName: ganymed00223552.root
701 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
702 The input file can be a ganymed-file after (ganymed*.root) or
703 before (ganymed*-summary.root) file. For example to select all events
704 from your on sample after cuts (excluding the ThetaSq cut) use
705 MFEvtNumber.Selector: DataType.fVal>0.5
706 To show all events from your on-sample after quality cuts
707 use the summary file instead.
708
709 - mars: new ways to call mars are implemented. Instead
710 of calling
711 mars filename.root
712 you can now also use
713 mars sequence.txt
714 or
715 mars sequence.txt inputpath
716 or replace sequence.txt by the sequence number if the default
717 sequence file should be used.
718
719 - mars: The default size has been increased
720
721 - mars: There are two new heckboxes which allow to switch off
722 the calculated image parameters
723
724 - callisto: was broken for MCs... fixed.
725
726 - callisto: improved calculation of spline coefficients a lot. This
727 leads to a further improvement of the event rate calibrating MUX
728 data of about 15% (175evt/s instead of 150evt/s)
729
730 - callisto: finally the raw data we read is now real 16bit (with
731 10bit precision) for MUX data and not a stripped 8bit number
732 anymore. Due to scaling of the numbers (without precision loss
733 into an [0-256[ range, the final numbers for pedestal, pedestalrms
734 and extacted signal don't change. However, at all places where
735 raw data is directly accessed (eg. saturation and variation
736 limits in the signal- and pedestal-extraction) the numbers
737 refer still to the data's 16bit range.
738
739 - callisto: The maximum arrival time difference used in the bad
740 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
741 for both, old FADC and MUX-FADC, data.
742
743 - callisto: Be aware that callisto is now calibrating the arrival time
744 in nanoseconds rather than time slices. Also all following tasks
745 have been changed to assume ns units now. If you star data
746 calibrated with an older version it might be necessary to adapt
747 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
748 to obtain optimal results. The plot in the PulsePos tab
749 will now be in ns, too. This might also mean that the Muon
750 analysis in star might not work as perfect as expected as long
751 as old files read in.
752
753 - callisto: The calibration constants of earlier updates got lost
754 somehow. All constants have been updated.
755
756 - star: The PSF is now determined from the profile of the ArcWidth
757 instead of arcwidth/radius. The old way gave to much weight
758 to the bins with low statistics. The reference lines have been
759 updated.
760
761 - star: For speed reasons events suitable for the muon analysis
762 are now also preselected by fConcCOG<0.1 which seems to be a very
763 good preselector for muons.
764
765 - star: is now calculating a new timing parameter the Slope along
766 the major and minor axis of the shower. Therefore a numerical
767 solution of a line-fit is used. To use MHillasExt.fSlopeLong
768 and MHillasExt.fSlopeTrans don't forget to multiply it with
769 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
770
771 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
772 have been removed from MNewImagePar. They have never been good for
773 anything.
774
775 - star: Implemented a new recursive algorithm which is supposed to be
776 faster. Also implemented new cleaning oiptions, which are:
777 + CleanLevel0:
778 The cleaning level above single core pixels can be kept
779 + KeepIsolatedPixels:
780 Define whether single core pixels should be kept
781 + TimeLevel1:
782 The coincidence window in nanoseconds to single used neighbors
783 + TimeLevel2:
784 The coincidence window in nanoseconds to two used neighbors
785 + PostCleanType:
786 MOde in which a time dependent post cleaning should be applied
787 0: No post cleaning
788 1: Require for each used pixels at least one used neighbor
789 within a time-window of CleanLevel1
790 2: Require for each used pixels at least two used neighbor
791 within a time-window of CleanLevel2
792 3: Require first two and second one used neighbor
793 within a time-window of CleanLevel1 and fCleanLevel2
794 respectively
795 + RecoverIsolatedPixels:
796 - recoveres isolated core pixels if they have a used neighbor
797
798 - mars/star: The new default cleaning is:
799 + CleanLevel1: 6.0
800 + CleanLevel2: 3.0
801 + CleanTime1: 1.75
802 + CleanTime2: 1.75
803 + PostCleanType: 3
804
805 - star/ganymed: The old spark-cuts have been replaced by new ones.
806 These new spark cuts have been cross checked with the sequences
807 84720 (before splitter), 101041 (after splitter) and 223539 (new
808 FADCs). In all cases they seperate pretty well, but of course not
809 perfect. Monte Carlos have suggested to tighten the cuts a little
810 bit further at low sizes. This has been done.
811
812 - ganymed: IMPORTANT - The spark cuts have been changed to match
813 all available data more or less well. This might mean that for
814 YOUR data there are still sparks visible.
815 Whenever you do an analysis you have to make sure that NO sparks
816 survive your cuts!
817
818 - ganymed: The old hadronness and size cuts have gotten new indices
819 (10, 11). The old indices 8 and 9 now mean an additional condition
820 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
821 If you want to switch off this cut just move the line far away enough,
822 e.g. by setting c[9] to -500. Please update your ganymed.rc files
823 accordingly!
824 The unit of c[9] is deg. It is the dist at which your cut will
825 cross the slope==0. The unit of the slope is ns/deg. So if
826 you readin files calibrated with an older Mars-version you
827 have to adapt the default value for c[9] to the FADCs:
828 - Multiply by two for the MUX FADCs (run number > 200.000)
829 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
830 - Multiply by 42 for the meaning of life (run number = 200.000)
831
832 - ganymed: The old Cut0 is now called CutQ and is calculated before
833 the source position is caluclated. If you need a quality cut
834 including source dependant data (be very carefull with this!)
835 you have to use Cut0 instead.
836
837 - ganymed: now properly supports three off regions in wobble mode.
838 It will be the default from now on in ganymed_wobble.rc. To change
839 the number of off-regions use
840 NumOffSourcePositions: 1
841 in your ganymed.rc. Also by default no off-theta cut will be done
842 anymore so that you will get a background level higher than the
843 signal level in your ThetaSq plot for ThetaSq>0.2.
844 Due to this be carefull changing the scaling mode away from
845 "None". You will underestimate your signal if your scale interval
846 is not properly set.
847 (Rem: ThetaSqN is no longer needed)
848
849 - ganymed: is now storing the events of all (on- and off-)
850 source positions even in the case of more than one off-source
851 position. This should allow sponde to work properly and the
852 energy estimation is done correctly in all cases (without any
853 "nearest position" trick)
854
855 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
856 with a real pointing model for the starguider is done, calibrated
857 with more than thousand tpoints taken from this date on.
858
859 - ganymed: was broken for Wobble-MCs... fixed.
860
861 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
862 has changed. Note that your old ganymed.rc will be incompatible
863 with the new algorithms! Please check the ganymed.rc files and
864 the class description of MFMagicCuts for more information.
865 It is recommended at the moment to use identical Disp-Parametrizations
866 for on/off- and wobble-mode. If cuts are optimized only
867 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
868 should be optimized. All other values should be kept as they are.
869 If you want to do an anylsis without timing a parameters, you can
870 switch off the timing cuts by seeting parameter 7 to a very small
871 value (eg. -99). To remove the slope parameter from the disp
872 paremtrization set parameter 8 to 0.
873
874 - ganymed: The distribution of observation time versus zenith
875 angle is now shown for off- AND on-data.
876
877 - ganymed: The contents of the source position plot are no longer
878 averaged, thus a lot of (fake) events between the two wobble
879 positions have disappeared.
880
881 - ganymed: There is a new tab "CutT" it contains the VsSize plots
882 with the CutT, whihc is defined in ganymed.rc, applied. It
883 is resonable to use your theta-cut for it, to see if there is
884 something strange (sparks!) in your signal-region.
885
886 - ganymed: To choose a dataset from a collection in a dataset file
887 use the new command line option "--dataset=12345"
888
889 - optim, sponde: should now properly support three off-regions.
890 Just produce your ganymed summary files with three off-regions.
891 optim and sponde will automatically get all off events from
892 all off-regions from this file. Please do not forget to
893 set the scaling in optimwobble.C properly:
894 fit.SetScaleUser(1./3);
895 it is not yet read in automatically (will follow soon).
896 In the case of fixed Scale you can also use
897 cuts.SetThetaCut(MFMagicCuts::kOn);
898 no off-cut needed.
899 Be carefull in case of three off-regions when switching on
900 scale mode. Make sure that the scale interval is set correctly.
901
902 - sponde: sponde.rc and sponde_onoff.rc are now idetical
903
904 - sponde: the resouce files have been rewritten with a lot of
905 comments and a well working parametrization for an energy estimator
906
907 - sponde: In the estimated energy versus monte carlo energy plot the
908 contents where exchanged.... fixed.
909
910 - sponde: the so called "accurate"-mode has been removed. It didn't
911 give any improvement in accuracy, only decreased execution speed.
912
913 - sponde: the so called "simple"-mode has been removed. It didn't
914 give any improvement in simple.
915
916 - sponde: the so called "refill"-mode has been removed. It was anyhow
917 not implemented.
918
919 - sponde: now checks whether the theta distribution of your on-data
920 and the theta-distribution of your Monte Carlo sample (after
921 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
922 sample is incomplete) execution is stopped. Execution can be forced
923 using the new option --force-theta. Use this option with care!
924
925 - sponde: Proper collection areas can now be constructed also from
926 Monte Carlo samples generated with different maximum impact
927 parameters. Note that in previous version you neither got
928 a warning or failure, nor was there any obvious sign that the
929 collection area was overestimated due to usage of files with
930 different maximum impact parameters.
931
932 - sponde: If MC files with different lower energy limits are used
933 the primary MC spectrum is artificially completed down to the
934 lowest energy used at all. WARNING: that this gives correct
935 collection areas ONLY if none of the events in this region would
936 survive your cuts at all.
937
938 - sponde: the output file now contains more information about
939 the spectrum (eg. the full 2D collection area histogram).
940 Note, that this information can only be written to the file
941 if it is stored automatically via command line argument.
942 If you only store the status display from within the display
943 the information is lost.
944
945 - sponde: added a new tab "Disp". It shows the residual of the disp
946 (Disp-Dist) versus several parameters and it is meant to judge the
947 quality of the disp estimator. In the ideal case the residual is zero
948 and doesn't depend on any variable. The tab is displayed after
949 CutQ and Cut0.
950
951 - sponde: added a new tab "Energy". It shows the residual of the
952 energy (lg(estimated energy)-lg(monte carlo energy)) versus
953 several parameters and it is meant to judge the quality of the
954 energy estimator. In the ideal case the residual is zero
955 and doesn't depend on any variable. In reality even a good estimator
956 can show residuals versus Monte Carlo energy. The tab is displayed
957 after all cuts.
958
959 - sponde: added a new tab "EventDist" showing the unweighted real
960 absolute number of events of your sample after cuts. This tells
961 you how many events with this energy you had in your MC files.
962 The same information you get from the error bars of the weighted
963 histograms, but this is less intuitive.
964
965 - sponde: The spectrum plots now show the crab- and 1553-spectrum
966 for comparison. It is not meant to show these curves in
967 publications, they are only for production.
968
969 - sponde: The OriginalMC tree with the events produced by corsika
970 is now processed only once
971
972 - sponde: Finally fixed most annoying bug, which has effected the
973 last bin of the collection area. It was the problem that binnings
974 of root histograms are from 1 to n (included) but there was a C-like
975 loop in sponde from 0 to n (excluded). Now the loop also includes
976 correctly under- and overflow-bins. The worse thing with this is,
977 that for the events in the highest bin not only the bin-content
978 was wrong, but also the weights applied to these events, which could
979 in pricipal effect also other parts of the distribution (eg. due
980 to energy estimation). Fortunately it effected only a few events
981 in most cases.
982
983
984
985 *** Version 1.2 (2007/05/14)
986
987 - database: The database now has two new values Unsuitable50 and
988 Unsuitable01. They express the number of pixels which are
989 unsuitable for more than 50%, respectively more than 1%, of
990 all calibrated event. It is a more accurate number than the
991 previously used numbers, because they only take the first
992 calibration (ignoring the interleaved calibrations) into account.
993
994 - database: The database now has two other new values UnsuitableMax and
995 DeadMax. They express the maximum number of pixels which were
996 unsuitable, respectively dead, during the sequence. Because
997 of high pedestal rms (cars passing) a few events with very high
998 numbers of unsuitable pixels can happen. Not to suffer from this
999 effect we don't take the highest 0.1% of the numbers into account.
1000
1001 - general: fixed a bug which caused callisto and star to stop working
1002 properly because the callisto output was currupted
1003
1004 - general: a script called scripts/makemovie has been added which
1005 simplified the process of producing several movies from a single
1006 sequence with different setup.
1007
1008 - callisto: Some more code cleanup. Started to remove old obsolete
1009 code from cvs.
1010
1011 - callisto: The extraction of the pedestal with the extractor was
1012 not random. It seems that extracting at one position is still biased
1013 (for example in the first or last slices we could still suffer from
1014 switching noise) Now it is completely random.
1015
1016 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1017 pedestal files) individual pixels could be skipped due to high
1018 variations. This was already the case for the pedestal extraction
1019 from the lo-gains since the beginning and properly handled
1020 there, but was introduced in the extraction from the pedestal files
1021 a while ago. To calculate the average value it was still divided
1022 by the number of events procesed not by the number of summands
1023 really summed. This let to a pedestal which was a tiny amount too
1024 small (for a few piels in the order of 0.1%). This led to an slightly
1025 positive offset of the randomly extracted pedestal for a few pixels.
1026 I doubt that this has a big effect on the result, because the effect
1027 on the individual numbers is quite small. Due to this it is suggested
1028 that you rerun your calibration to make sure you are without any
1029 avoidable bias.
1030
1031 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1032 the median rms of the absolute arrival time and expressed in significance
1033 levels. This replaces the old meaning of an abolute upper limit. An
1034 absolute upper limit doesn't make much sense, because in our data
1035 all arrival times are shifted at the same time (in fact it might be
1036 a shift of the artificial trigger w.r.t. to the light flash).
1037
1038 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1039 of the number of unsuitable pixels over the whole sequence. This
1040 is usefull mainly to judge if an intermediate calibration had
1041 problems.
1042
1043 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1044 of the number of dead pixels over the whole sequence. Dead pixels
1045 in this context are unmapped pixels, i.e. pixels which could not
1046 be interpolated, and thus are ignored in the further analysis.
1047
1048 - callisto: It is now possible to use the position of the maximum
1049 of the spline as arrival time instead of the leading edge even
1050 when using the integral for the signal. Therefor set the extraction
1051 type to kIntegralRel ("IntegralRelative") and the relative height
1052 ("HeightTm") to -1:
1053 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1054 MJPedestalC1.ExtractSignal.HeightTm: -1
1055
1056
1057
1058
1059 *** Version 1.1 (2007/04/27)
1060
1061 - general: The new class MGeomCamDwarf contains the camera geometry
1062 for our prefered Dwarf camera and can be used to create general
1063 geometries of roundish or hexagonal cameras.
1064
1065 - mars: The default cleaning is now abolute 8.5/4.0.
1066
1067 - mars: The resource file mars.rc now contains examples for MUX data
1068
1069 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1070 data containing only 10-bit information is still cooked down to
1071 8-bit, by cutting away the lowest 8-bit.
1072
1073 - merpp: When reading raw data the data is now stored in a single
1074 array. The lo-gain array is obsolete. The interface stays the same.
1075
1076 - callisto: To process the new MUX data use the resource file
1077 callisto_mux.rc
1078
1079 - callisto: The -root and -raw options to read merpped raw data have
1080 been removed
1081
1082 - callisto: If the -mc option is given the sequence-name can now be
1083 replaced by the MC sequence number
1084
1085 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1086 -mc option can now be omitted
1087
1088 - callisto: Started further simplification by removing obsolete
1089 dependancies on MCalibIntensity*Cams.
1090
1091 - callisto: removed unsused intensity calibration from MJCalibration
1092 for further simplification
1093
1094 - callisto: for simplification removed references to
1095 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1096 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1097 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1098 (this should at minimum change nothing at all, and at maximum
1099 improve thing if these containers where somewhere not handled
1100 properly)
1101
1102 - callisto: Added the option to write an event movie. Please use
1103 this option with care (huge files) but exessively to understand
1104 our events. For further documentation please refer to the
1105 IACT wiki
1106 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1107
1108 - callisto: Improved binning for the pulse position check histogram
1109
1110 - callisto: The code calculating the pulse position checknow takes
1111 the pedestal into account
1112
1113 - callisto: The arrival time is now stored with full precision this
1114 helps to get rid of artefacts in histograms. For the signal this
1115 is not necessray because it is displayed in log-scale anyhow
1116
1117 - callisto: Fixed a problem with internal exclusions. Pixels which
1118 have once been marked as unsuitable didn't get the necessary
1119 histograms filled anymore to be rechecked with each interleaved
1120 calibration.
1121
1122 - callisto: The relative arrival time resolution (the rms of the
1123 relative arrival time offset) is now checked against its
1124 median and the median deviation, instead of the average
1125 plus an absolute offset.
1126
1127 - callisto: The relative arrival time offset is now calculated
1128 w.r.t. its median not w.r.t. to an artificial reference pixel.
1129
1130 - callisto: The relative time calibration now marks pixels with
1131 outlaying offset as unsuitable
1132
1133 - callisto: The interleaved relative time calibration has been switched
1134 on. The advantage is that pixels which are marked as outliers
1135 now can recover. An improvement over time is not expected, because
1136 the relative time calibration seems stable.
1137
1138 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1139 option can now be omitted.
1140
1141 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1142 or the option "-mc" is specified as default the monte carlo datacenter
1143 paths (/magic/montecarlo/...) are used if not overwritten in the
1144 dataset file.
1145
1146 - ganymed: The output files now contain run- and event-number for all
1147 events, accessible as RunNumber.fVal and EvtNumber.fVal
1148
1149 - ganymed: Added a plot showing the source position in the camera also
1150 for wobble mode
1151
1152 - ganymed: In addition to the existing task which can be setup to
1153 be executed after Cut1 a final task called "EstimateEnergy"
1154 has been added, executed before writing the final output
1155 (ganymed00000000.root). The task setup in all three cases
1156 can be choosen individually. (For all three(!) cases you
1157 can for example choose MRanForestCalc. For examples see all
1158 sponde*.rc and all ganymed*rc)
1159
1160 - ganymed: If a container "MEstimatedEnergy" is found in the
1161 parameter list (eg. because it was setup by MEstimateEnergy)
1162 it will be written to the output file.
1163
1164
1165
1166 *** Version 1.0 (2007/02/16)
1167
1168 - database: Website to plot values from the database has been added.
1169
1170 - database: The rate of spark events as found by star is now kept
1171 and the rate after cleaning is now with spark events subtracted
1172
1173 - general: The changes to the interpretation of phrases lead to
1174 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1175
1176 - general: Added example files how you can create your own calendar
1177 (eg. as christmas present) with Mars. Just run
1178 root macros/tutorials/calendar.C
1179
1180 - general: Added a possibility to display grouped data in the plotdb.C
1181 macro (and similar macros). This allows to plot hourly, nightly,
1182 weekly, monthly and yearly averages.
1183 For more details see the plotall function of the macro
1184
1185 - general: fixed the error display of the camera display. It showed
1186 wrong results.
1187
1188 - general: fixed a memory leak when reading many MStatusDisplays
1189
1190 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1191 between a spherical and a parabolic mirror
1192
1193 - callisto: We have a new pulse position check which takes the properties
1194 of the extractor automatically into account. So no need to set
1195 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1196 left is done. If possible the lo-gain extraction start and hi-gain
1197 extraction end is changed accordingly. If no proper extraction range
1198 can be set (hi-gain too much to the left) an error is raised.
1199
1200 - callisto: New swapped pixels have been found and corrected
1201
1202 - callisto: Redone the signal extraction this includes:
1203 + Unified the algorithms to extract the pedestal for all pedestal
1204 extractions done
1205 + Unification of hi- and lo-gain into one array
1206 + Unification of hi- and lo-gain extraction for Spline and
1207 Digital Filter (means now exactly the same algorithm is used,
1208 not a copy-and-pasted one)
1209 + Store pedestal subtracted data in a common place
1210 + Improved extraction algorithms. If the algorithms search a
1211 maximum but don't find one they don't return the maximum anymore
1212 + Improved the extraction such that a information for signal
1213 and time which is consistent is returned
1214 + replaced the numerical spline with a (not slower) analytical
1215 solution
1216 + Lowered the saturation limit from 250 to 245 to make sure that
1217 we are far away in all pixels from problems with the clock-noise
1218 + The start of the lo-gain extraction is calculated from the hi-gain
1219 arrival time. In case of saturation an estimation is used.
1220 + the hi-gain window was extended to slice 16. This allows extraction
1221 of very late pulses in single pixels or of huge hadron showers.
1222 + Now uses the lo-gain extraction range for pedestal extraction,
1223 not the hi-gain range in the lo-gain
1224
1225 - callisto: New hi-/lo-gain calibration constants have been produced
1226 for all periods from the statistic of the whole period. They are
1227 now used automatically depending on the periods. The old constants
1228 where deviation in avarega about 2%-3%. The constants are very
1229 stable from period to period (<<1%) except for exchanged channels.
1230 In a few cases the constants used so far were off by 1%-2% (maybe
1231 temperature effects?)
1232
1233 - callisto: To gain obsolete space we do not write the
1234 MPedestalFundamental anymore. Also calibration and bad pixel
1235 treatment is not done for it anymore because it has never been used.
1236
1237 - callisto: Fixed a bug in the seuqence handling which caused the
1238 light condition to be ignored
1239
1240 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1241 basically the same as "Cleaned" but the distribution devided into
1242 the events fullfilling a spark cut or being rejected by it.
1243 This cut can be changed from star.rc (see example inside) by
1244 the "SparkCut" directive
1245
1246 - star: Star displays now the average individual pixel-rate (IPR) versus
1247 time and the average discriminator threshold (DT) of all pixels.
1248
1249 - optim: fixed a problem with the optim-macros which was due to a bug
1250 in the new phrase parsing
1251
1252 - ganymed: To get a nice FalseSource plot (instead of the all-information
1253 debug plot displayed as a standard plot) use the context menu
1254 somewhere between the two upper plots, click on "DrawNicePlot"
1255 and enjoy the result. (It is the same context menu which contains
1256 the other options)
1257 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1258
1259 - ganymed/optim/train: The cut program, trainings- and optimization
1260 macros could run with less files found than expected from the
1261 sequence-files. No the execution is stopped in this case.
1262
1263 - ganymed: now stores the dataset in the output file with all information
1264 contained (as sequence number, sequence path, data path) so that the
1265 used dataset file can be recreated complete from the output
1266
1267 - sponde: now also allows the uasge of random forest
1268
1269 - sponde: added a plot showing the cut efficiency
1270
1271 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1272 errors (eg. effecting the collection area) because the errors of the
1273 two histograms were swapped in the calculation, which makes a difference
1274 in the case the histograms contains weighted events. Aditionally the
1275 totalarea was incorrectly taken into account, which results in too small
1276 errors, which makes a difference at low statistics were the errors
1277 or the collection area dominate.
1278
1279
1280
1281 *** Version 0.10.3 (2006/10/23)
1282
1283 - database: Implemented ObservationMode flag in websites.
1284
1285 - database: For sequences there is now also the stoptime available on the
1286 websites.
1287
1288 - database: Removed ManuallyChanged flag from sequence-info websites,
1289 as it is not needed anymore with the new sequence building algorithm.
1290
1291 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1292 Class for calculation of confidence intervals (upper limits).
1293 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1294 Please read the class instruction of TRolke for more information.
1295
1296 - general: The programs now return 0xfe if the requested resource file
1297 doesn't exist.
1298
1299 - general: Errors comming from root itself are now not output to
1300 stderr anymore but to our default (colored) log-stream.
1301
1302 - general: Changed the interface to TFormula such that now everything
1303 is parsed by TFormula, which should allow to use phrases even
1304 without paranthesis correctly parsed.
1305
1306 - callisto: replaced the AdHoc number of effective integration slices
1307 in the digital filter by an average of the correct number, averaged
1308 over all possible set of weights. This also gives correct numbers
1309 for the lo-gains which were totally wrong before.
1310
1311 - callisto: drastically reduced memory consumption by not storing
1312 all intermediate calibration results in memory anymore (we might
1313 write them into a file in the future)
1314
1315 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1316 debug plot displayed as a standard plot) use the context menu
1317 somewhere between the two upper plots, click on "DrawNicePlot"
1318 and enjoy the result. (It is the same context menu which contains
1319 the "DrawAll" option)
1320 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1321
1322
1323
1324 *** Version 0.10.2 (2006/10/15)
1325
1326 - general: changed the building of the sequence files such, that
1327 the source-/project name in case of wobble-sources is not the
1328 source/project of the first data run anymore but the new generalized
1329 wobble source/project
1330
1331 - general: Added some functions to MAstro to calculate sun and
1332 moon properties
1333
1334 - general: Added two new macros (starvisday.C and starvisyear.C)
1335 which allow to plot the visibility of several stars in one day
1336 or of one star along one year
1337
1338
1339
1340 *** Version 0.10.1 (2006/10/11)
1341
1342 - general: HTML logging output was distorted... fixed.
1343
1344 - general: Changed the writing of the sequencefiles such that only
1345 as many pedestal files as giving at least 1000 pedestal events which
1346 are nearby the first calibration run are used as pedestal runs
1347
1348 - sponde: In the calculation of the collection area(s) and the
1349 distribution for MOnte Carlo and estimated energy the error
1350 calculation was wrong because root didn't take the errors
1351 properly into account... fixed.
1352
1353
1354
1355 *** Version 0.10 (2006/10/10)
1356
1357 - general: all executables now check consistency of the root version
1358 installed with the root version used for compilation. The return
1359 code in this case is 255.
1360
1361 - general: The algorithm to build seqeunces has been redesigned
1362 completly. It is now more flexible in terms of a resource file
1363 resources/sequences.rc which can be used to partly overwrite
1364 the default algorithm and defined the important part of the
1365 algorithm. It also takes correctly into account several ways
1366 of taking wobble-data. Currently the new algorithm doesn't take
1367 the number of pedestal events anymore into account (so a sequence
1368 could have much less than 1000 pedestal events and data runs are
1369 no-more used instead)
1370
1371 - general: a lot of small changes to make the code compatible with
1372 root 5.12/00 and gcc 4.1
1373
1374 - general: Fixed some warnings thrown if more warnings are switched
1375 on in the compiler
1376
1377 - general: Added a function to MMath which returns the Median of
1378 the distribution abs(y[i]-median) but at 68:32 division instead
1379 of 50:50, which is somehow the median counterpart of the rms.
1380
1381 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1382 even if they are compressed with gzip (recommended compression
1383 is with "-1")
1384
1385 - showplot:
1386 + batch mode creation of image files now works with root 5.12/00
1387 + added support for writing bmp (though it never produces
1388 bmp which can be read by programs like xv or gimp)
1389 + added support for xml
1390 + added new option to start the display with a different size, by
1391 --display-width=nnn or --display-height=nnn
1392 + added options to define the canvas size when the display is started
1393 --canvas-width=nnn or --canvas-height=nnn
1394 the option can also be used for batch-mode conversion
1395 + added an option which automatically fits the display size to the
1396 desktop-size: --auto-size
1397
1398 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1399
1400 - merpp: allow the reports to have 1000ms due to a bug in the camera
1401 program.
1402
1403 - callisto: New swapped pixels have been found and corrected. For
1404 details see MRawRunHeader::FixAssignment()
1405
1406 - callisto: Callisto now raises an error if one of the input files could
1407 not be opened.
1408
1409 - callisto: In some rare cases it could happen that in the signal
1410 extraction of the digital filter the extractor returned nonsense
1411 results due a wrong initializion of a variable (this happens in
1412 cases in which the extracted signal is exactly zero or the
1413 digital filter couldn't slide because of a too small extraction
1414 window, which could happen in the lo-gain extraction)
1415
1416 - callisto: The lo-gains have been marked as valid in some cases
1417 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1418 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1419 smaller than the number of slices (fLoGainWindowSize) needed
1420 by the lo-gain extractor
1421
1422 - callisto: Updated absolute calibration constants (muon calibration)
1423
1424 - callisto: fixed a bug which caused the hi-gain saturation not
1425 to be handled properly in the spline (the position of the
1426 saturation was calculated incorrectly)
1427
1428 - callisto: fixed a bug which gave weird results if hi- _and_
1429 lo-gain could not be extracted properly. In some cases hi-
1430 and lo-gain have not been extracted at all and the random result
1431 got calibrated. In other cases the hi-gain was saturating and the
1432 lo-gain has not been extracted. For this a completly arbitraty
1433 scale factor was applied to the result from extracting the
1434 charge of the saturating hi-gain.
1435
1436 - callisto: improves handling of extracted signal if lo- and/or
1437 hi-gain could not be extracted properly. If no appropriate
1438 calibration of either the signal or the arrival time is possible
1439 the pixel is now markes as unsuitable instead of estimated.
1440
1441 - callisto: Fixed a problem in the spline extraction which gave
1442 weird results if the signal was extracted from the first (and
1443 highest) slice (as a workaround extraction from the first
1444 slice has been forbidden)
1445
1446 - callisto: Fixed a bug regarding the use of the QE which doesn't
1447 effect the result because the default is used anyhow.
1448 (The bug was there since 14/07/2005)
1449
1450 - callisto: Changed the default for fgLoGainStartShift to -2.4
1451
1452 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1453 factors to be always 10 for all pixels as soon as the first
1454 calibration update has happend.
1455
1456 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1457 was off by more than one slice (which gives wrong values for
1458 pixels which have saturated the hi-gain) This was a problem
1459 mainly for timing studies, not so much for the automatic standard
1460 analysis. Also the values for the Spline have been changed slightly:
1461 + Digital Filter from 1.70 to 0.95
1462 + Spline from 1.39 to 1.30
1463 The numbers were sorted out by an extensive test in the
1464 test-database.
1465
1466 - callisto: Removed the tab showing the average calibrated arrival
1467 time. It never gave useful information.
1468
1469 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1470 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1471 and both were extracted because the hi-gain was above the
1472 LoGainSwitch.
1473
1474 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1475 lo-gain pulse position (after application of LoGainOffset, which
1476 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1477 have saturated and both were extracted because the hi-gain was above
1478 the LoGainSwitch.
1479
1480 - callisto: After extensive tests a new threshold level for determination
1481 of the pulse position has been found at 50phe. This is due to the
1482 fact that for lower pulses the arrival time changes its average
1483 behaviour dramatically. It tends to the average of the extraction
1484 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1485
1486 - callisto: Added two more plots to the calibration part. The average
1487 extracted signal and the average extracted arrival time as
1488 extracted by the signal extractor (This can help debugging problems
1489 because it doesn't involve a fit)
1490
1491 - star: changed the fit for the effective on time such that initial
1492 values are calculated automatically now instead of using build
1493 in values. This makes the fit more indepedant of the underlaying
1494 rates. With a test of ~350 sequences in the test database it could
1495 be shown that the new fit gives the same result +/-1sek.
1496 The highest deviation was +5s the lowest -10s. You can now control
1497 the bahaviour with two resource values:
1498 MHEffectiveOnTime.FistBin: 3
1499 MHEffectiveOnTime.NumEvents: 12000
1500 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1501 from the resulting gamma candidates
1502
1503 - star: The Center histogram in MHHillas is now by default displayed
1504 with the colz draw-option
1505
1506 - ganymed: now produces valid error codes if failed
1507
1508 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1509 with the option "hadronness" instead of "area" or "both" if
1510 you want to use both cuts. The hadronness cut includes a fixed
1511 cut in hadronness (index 8) and a fixed cut in size (index 9).
1512
1513 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1514 the M3Long of the anti source to be not properly evaluated
1515 (actually is was evaluated as a unique random number) in case
1516 of optimization with anti-theta cut switched on. This might have
1517 lead to improper, but not necessarily wrong, optimization results.
1518
1519 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1520 how to use random forest
1521
1522 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1523 ganymed_onoff.rc. Seems to be unintentional that they were different.
1524
1525 - sponde: Since the introduction of the possibility to define a
1526 normalization energy instead of using the integral the default
1527 was not using the integral anymore but a normalization energy of
1528 1GeV. It is now the integral again.
1529
1530 - sponde: Fixed a problem in the weighting which did not allow
1531 a MC slope of -1.
1532
1533
1534
1535 *** Version 0.9.6 (2006/05/24)
1536
1537 - general: changed the binning of the azimuthal profile of the camera
1538 such that it is aligned with the 60deg boundaries.
1539
1540 - merpp: better handling of problems with the TH, TD part of the
1541 CC-REPORT for files older than 200507190 and 200412210
1542 respectively
1543
1544 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1545
1546 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1547
1548 - callisto: if an arrival time is extracted outside the fadc range is
1549 was set to the boundary before. Now a random number is assigned
1550 instead to avoid unfortunate coincidences of arrival times just
1551 by this arbitrary value.
1552
1553 - callisto: added a new option to callisto.rc which allows
1554 to set the maximum arrival time difference allowed for the
1555 badpixel algorithm to determin whether a pixels belongs to a shower:
1556 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1557
1558 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1559 to 0.9 as suggested by Stefan due to a recent study on the fraction
1560 of pixels surviving the image cleaning
1561
1562 - callisto: switched off error in case of "pulse is too much to the left"
1563
1564 - callisto: The extraction window is not adapted anymore. This means that
1565 the pulse is extracted from the full range. The draw-back is that the
1566 background (pedestal) will become slightly higher. Switching on/off
1567 the PulsePosCheck in the callisto.rc only effects filling the
1568 histograms.
1569 WARNING: If the pulse is too much to the left data is calibrated!
1570 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1571 in the database to make sure that your data is valid!
1572
1573 - star: Show also the number of stars correlated correctly by the
1574 starguider
1575
1576 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1577 than one off-source region in wobble-mode. To use it add the following to
1578 your ganymed_wobble.rc:
1579 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1580 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1581 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1582 + Cut1.ThetaCut: None
1583 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1584
1585 - ganymed: in the case the latest report is older than a default (currently
1586 one minute) and the current report will be skip the starguider
1587 correction and calibration will be reset. The maximum age can be
1588 setup from ganymed.rc by (minutes):
1589 MPointingDevCalc.MaxAge: 1.5
1590
1591 - ganymed: A first implementation showing all size-bins for the theta-sq
1592 resp. alpha-plots in a single tab automatically
1593
1594
1595
1596 *** Version 0.9.5.1 (2006/05/05)
1597
1598 - general: Added a new option "zdiff" to the Makefile which runs
1599 "cvs diff" as "make diff" would do, but with compression
1600
1601 - general: accelerated MTFillMatrix (used for eample in all training
1602 and optimization macros) by skipping some obsolete calles in the
1603 eventloop the first and second loop could be accelerated by ~20%
1604
1605 - general: Added a missing feature in the MFilterList class which
1606 prevented MFEnergySlope from working correctly in trainenergy.C
1607
1608 - general: Accelerated the random forest training and usage a bit
1609
1610 - merpp: Adapted to new raw data file format version 6
1611
1612 - merpp: fixed a problem with reading the starguider reports
1613 after 6.3.2006
1614
1615 - callisto: At some times six pixels had to be exchanged manually in the
1616 data. If the pixels to be swaped are both not found, an error was raised
1617 and calibration was stopped. Now it is assumed they are intentially not
1618 mapped and the Error has been changed to a Warning.
1619
1620 - star: Added new image cleaning based on the arrival time of the shower.
1621 The new cleaning can be accessed using the parameter "Time" instead of
1622 the the old one (like "Absolute) in the star.rc-file.
1623 Recommended parameters:
1624 + MImgCleanStd.CleanLevel1: 8.2
1625 + MImgCleanStd.CleanLevel2: 5
1626 + MImgCleanStd.CleanRings: 2
1627 + MImgCleanStd.KeepSinglePixels: No
1628
1629 - star: Simplified the calculation of the effective on time. By letting
1630 the fit start in the third bin the result should become more stable.
1631 The fit quality is now ignored for the theta-plot which is not used
1632 in the analysis later. Still better pre-cut which, for example,
1633 remove events triggered by car-light (rate changing on a short
1634 time-scale) are missing.
1635
1636 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1637 for optimization (kWeakSource) which is suggested by the Berlin
1638 people for weak sources.
1639
1640 - macros: plotdb.C:
1641 + if no dataset and no time-interval is given only sequences with
1642 an effective on-time above five minutes are plotted anymore
1643 + added a new tab "RelTime" displaying the relative on-time
1644 (effective on-time divided by the observation time)
1645
1646 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1647 the optimization became a lot faster
1648
1649 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1650 To display them just delete the pads displayed on top.
1651
1652 - ganymed: fixed a bug which could cause strange behaviour in wobble
1653 mode if no starguider information was available due to an incorrect
1654 initialization of the starguider calibration
1655
1656 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1657 be changed from within the plot. It can also be setup from the
1658 resource file using:
1659 + MHDisp.fScaleMin: 0.325
1660 + MHDisp.fScaleMax: 0.475
1661
1662 - ganymed, showplot: Fixed a problem with the fit to the off-data
1663 (HistOff) which could cause a time lag or an inifinite loop.
1664 The bug did not effect the results at all.
1665
1666 - sponde: Added a new tab showing the effective collection area after
1667 trigger (including the software trigger)
1668
1669 - sponde: MMcSpectrumWeight has a new option which allows to define
1670 the scaling factor not by the integral of the events but at
1671 a defined energy:
1672 e.g. MMcSpectrumWeight.NormEnergy: 200
1673
1674 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1675 eventloops the loop could be accelerated by ~20%
1676
1677
1678
1679 *** Version 0.9.5 (2006/03/13)
1680
1681 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1682 and added the standard Disp-parametrization
1683
1684 - macros: added a new macro datacenter/macros/plotstat.C allowing
1685 to plot statistics about the data processing
1686
1687 - macros: added a new macro to plot the muon correction coefficients
1688 versus period (macros/plot/mucal.C)
1689
1690 - showplot: path inflation for ganymed files was broken
1691
1692 - callisto: Fixed an important bug. When the number of saturating pixels
1693 were calculated the bad pixel information already available from the
1694 calibration was ignored. This yields wrong values in case pixels
1695 are broken and saturate all the time or randomly.
1696
1697 - callisto: Updated Muon calibration constants. Spline data now also uses
1698 different values for different periods
1699
1700 - star: The time-evolution shown in the effective on-time plot now displays
1701 the axis range (if there are no holes it should be similar to the
1702 effective on-time)
1703
1704 - star: Added two new image parameters:
1705 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1706 the three pixels next to the center of gravity and the size
1707 + MNewImagePar.fConcCore: The ratio of the signals of all
1708 pixels inside or touching the ellipse and the size
1709
1710 - ganymed: now stops in requested source isn't found in catalog file
1711
1712 - ganymed: Many improvements to the phi-plot in wobble mode:
1713 + with a template the ideal background is displayed
1714 + a possible camera inhomogeneity is taken into account
1715 + the anti theta cut is better supported
1716 + the phi cut is automatically calculated from the theta cut
1717 See the examples in ganymed_wobble.rc for more details.
1718
1719 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1720 times the bin-width instead of the absolute energy
1721
1722 - ganymed: New cuts for on/off and wobble mode
1723
1724 - ganymed: The smearing of the False Source plot has been increased
1725 to 0.06
1726
1727 - ganymed: The starguider calibration can now be changed from the
1728 resource file.
1729 See the examples in ganymed*.rc for more details.
1730
1731 - ganymed: added a new option for on-/off-observations
1732 MJCut.RandomSourcePosition
1733 If switched on the distribution of observation time of the source
1734 position in the camera is calculated from the on-data and randomly
1735 applied with this distrbution to the off-data.
1736
1737 - ganymed: by skipping some obsolete calles in the eventloop the
1738 first and second loop could be accelerated by ~20%
1739
1740 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1741 position in the off-data randomly according to its distribution in the
1742 on-data.
1743
1744
1745
1746 *** Version 0.9.4.3 (2006/02/13)
1747
1748 - general: Fixed a bug in most of the programs which prevented the
1749 compile date in the startup message to be displayed
1750
1751 - general: Simplified program calls. The following abbreviations
1752 are now possible:
1753 showlog callisto 55599
1754 showplot signal 55599
1755 star 55599
1756 callisto 55999
1757 ganymed 2
1758 In this cases the corrsponding root-, log-, sequence- or dataset-
1759 filename is automatically compiled using the default datacenter
1760 paths ("/magic/*")
1761
1762 - general: Fixed a long outstanding bug which made axis tick marks
1763 disappear if MDataFormula was used (eg. abs(x))
1764
1765 - general: Updated MMath with new functions to calculate the results of
1766 a exponential, logarithmic and powerlaw fits analytically.
1767
1768 - general: Updated some macros with comments:
1769 + macros/optim/optimdisp.C
1770 + macros/optim/optimenergy.C
1771 + macros/optim/optimwobble.C:
1772
1773 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1774 files) now allows adding a pre-cut like in the optimization. E.g. this
1775 is useful to perform g/h-separation cuts before training the random
1776 forest.
1777
1778 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1779 correctly assigned in the raw data assignement table. A fix to correct
1780 the assignment tabel have been implemented.
1781
1782 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1783 by 90, 180 and 270 deg.
1784
1785 - general: the macro plotdb.C now allows to highlight sequences belonging
1786 to a datset. For more details see the descritions in the macro.
1787
1788 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1789 of the display, it gave wrong results espacially for big sizes.
1790 Now the embedded canvas should always have a ratio width/height=3/2.
1791 The "Size" options have been updated with values fitting the 3/2
1792 size ratio.
1793
1794 - RanForest:
1795 + Updated the random forest classes to support also the
1796 regression method implemented by Thomas H.
1797 + added new tutorial macro how to train the random forest
1798 for energy estimation (macros/optim/rfenergyest.C)
1799 + new classes to train the random forest (still in development)
1800 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1801 + new tutorial macros for random forest training in macros/train
1802 trainenergy.C, traindisp.C, trainseparation.C
1803
1804 - mars: now allows to setup a cut in the resource file mars.rc to choose
1805 the events to be displayed, eg:
1806 Cut.Condition: {0} && {1}
1807 Cut.0: MHillas.fSize>100
1808 Cut.1: MHillas.fSize<900
1809
1810 - merpp: Made aware of the new .rep format 200510250. This includes
1811 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1812 the discriminator thresholds (MCameraTD) and the disciminator
1813 delays (MCameraTD). All of them come with the CC report and are therefor
1814 written to the CC tree.
1815
1816 - callisto: fixed a bug in the calculation of the arrival times in
1817 the Digital Filter. They were all shifted by the same amount
1818 fHiGainFirst. This caused an offset in the order of the position of
1819 the left border of the extraction window in the times calculated
1820 from high-gain and from low-gain. The bug effected only the absolute
1821 arrival times. The bug was there since 30.1.2005.
1822
1823 - callisto: Changed the ExtractionWindow for the pulse position check
1824 such that the camera inhomogeneity becomes as less as possible and
1825 comparable to the pulso position check switched off. More details
1826 on the study will be given at our result web-page.
1827
1828 - ganymed: ganymed.rc, ganymed_onoff.rc:
1829 changed to new cuts trained with 1ES1218 and Crab-data
1830 for maximum sigma*log10(excess)
1831
1832 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1833 a new option was implemented to estimate Disp (CalcDisp)
1834
1835 - ganymed: Implemented two new options which allow
1836 to overwrite the default path to search for the sequence files
1837 --ins=/magic/sequences
1838 and where to search for the image data
1839 --ind=/magic/data/star
1840
1841 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1842 dx/dy from the resource file by
1843 MSrcPosCorrect.Dx
1844 MSrcPosCorrect.Dy
1845
1846 - ganymed: fixed reading the source catalog. Only as many chars
1847 as the requested source name had were compared (If a source
1848 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1849 were requested it could happen that the coordinates of
1850 "1ES1218" were read) The source coordinates are now printed
1851 in addition to its name to the logging output.
1852
1853 - ganymed: changed the background fit in the case of a ThetaSq function
1854 from a polynomial to a exponential, this should give a big improvement
1855 for on-only analysis'
1856
1857 - ganymed/sponde: Calculation of the error of single size-/energy-
1858 bins now uses Li/Ma (5) instead of LiMa (17)
1859
1860 - sponde: Added a plot E^2*dN/dE
1861
1862 - sponde: The energy estimator plot should now show values like
1863 they are commonly used.
1864
1865 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1866 (a powerlaw with cutoff didn't work before)
1867
1868
1869
1870 *** Version 0.9.4.2 (2005/10/01)
1871
1872 - general: added new tutorial macro macros/tutorials/threshold.C:
1873 how to calculate the threshold
1874
1875 - general: added a new game. Start it from the interpreter with
1876 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1877 and MagicReversi)
1878
1879 - general: neighbor pixels in MGeoms are now sorted clockwise
1880
1881 - merpp: made aware of new format 20050829-0
1882
1883 - callisto: New scale factors from muon analysis, stored in new
1884 resource file resources/calibration.rc
1885
1886 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1887 the eventloop if something went wrong. This is necessary for the
1888 automatic processing
1889
1890 - callisto: Implemented a new treatment for the time information
1891 developed by S.Ruegamer, this should give much better response than
1892 the old very primitive algorithm. This is especially important
1893 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1894 treatment was buggy! As neighbor pixels to interpolate the
1895 arrival times always the pixels 0 to 5 were taken)
1896
1897 - callisto: In addition to the new treatment of arrival times the
1898 decision of the treatment whether a pixel contains shower
1899 information or not is used to improve the signal interpolation
1900 further. Previously interpolated pixels showed a non-zero signal
1901 do the peak searching signal extractors. Having a signal pixel
1902 beside raised the signal above the cleaning level. Thus the
1903 pixel survived cleaning to often but with a too low mean signal.
1904 By replacing empty pixels with a gaus (mean and rms from the
1905 corresponding Area entries in MPedPhotCam) this effect can
1906 be supressed.
1907
1908 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1909 got lost when the events were stored by the calibration... fixed.
1910 (This was no problem for normal image cleaning because the pixel
1911 content was artificially set to 0 not surviving standard cleaning
1912 algorithm)
1913
1914 - callisto: Fixed a bug which caused the random and peak-search pedestal
1915 extracted with an extractor to be exchanged for the first (roughly)
1916 500 events (*Extractor and *ExtractorRndm).
1917 (They were simply exchanged in callisto.cc) This bug might have been
1918 introduced in Mars 0.9.4 when the order of calculation of the two
1919 types of pedestal in callisto got exchanged. The bug only effects
1920 the first seconds of data of each sequence.
1921
1922 - star: Taking the arrival time of Muons into account the calculation
1923 of the parameters could be made independant of the noise
1924 (pedestal rms). The dependance was due to the bias of the peak search
1925 extractor. Now only a ZA dependamcy is left which is not yet fully
1926 understood.
1927
1928 - ganymed: The sequences were still not sorted correctly in any case,
1929 because they were sorted by the full qualified path name. Now they
1930 are sorted by their sequence number.
1931
1932 - ganymed: new values for the spark-event-cut
1933
1934 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1935
1936
1937
1938 *** Version 0.9.4.1 (2005/08/18)
1939
1940 - callisto: fixed some problems with the calibration in case of
1941 inteleaved events. Therefor the final and some intermediate
1942 fits are skipped which would take place on partly filled #
1943 histograms and gave wrong results or failed completely.
1944
1945 - callisto: If the intermediate finalization of the histograms
1946 calculating the mean charge of the calibration signal fails
1947 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1948
1949 - ganymed: Fixed some bugs which caused problems in On-only mode.
1950 Still the false source plot doesn't give reasonable results.
1951
1952
1953
1954 *** Version 0.9.4 (2005/08/05)
1955
1956 - general: Fixed the ZA binning. It did not correctly fit the
1957 MC binning
1958
1959 - general: Added a class to correct for the missfocussing in
1960 April (MSrcPosCorrect)
1961
1962 - general: Random Forest energy estimator should now work properly
1963
1964 - general: MHCamera now displays the profiles in deg instead of mm
1965
1966 - general: MH::SetPalette offers a lot of new palettes
1967
1968 - general: MHillas - the case of CorrXY==0 is now handled properly
1969
1970 - general: implemented the possibility to change the line and
1971 marker style of a sky-grid drawn by MAstroCatalog
1972
1973 - general: Runs in sequences and datasets are now automatically
1974 ordered (it is assumed that the order of their filenames correctly
1975 represents the order of observations) to ensure correct reading
1976 of the subsystem data
1977
1978 - general: Runs cannot be added to a sequence twice anymore. Also
1979 Sequences cannot be added twice anymore to a dataset.
1980
1981 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1982 It gave wrong results by 1./2pi
1983
1984 - showplot: got a new option to start a root interpreter, too
1985
1986 - mars: now displays a rough estimate of Disp and the third moment
1987
1988 - mars: now displays the event time MTime if available
1989
1990 - mars: show muon parameters graphically
1991
1992 - mars: now the file to open can be given as commandline
1993 argument
1994
1995 - merpp: Added support for new arehucas version >= 200507190
1996 implementing values for three temperature sensors in the
1997 counting house (MCameraAUX) and the name of the HV settings file
1998 (MCameraHV).
1999
2000 - merrp: Also fixed some problems with wrong versions numbers stated
2001 by arehucas and implemented some fixed for old versions (<200407070)
2002
2003 - callisto: MCalibrationHiLoCam can now be printed from its context
2004 menu, eg in the TBrowser
2005
2006 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2007 - 1.39 (MExtractTimeAndChargeSpline)
2008 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2009 This is important mainly for timing studies.
2010
2011 - callisto: Changed limits in MHCalibrationChargeCalc from
2012 - -100.125 to -98 (fgChargeHiGainFirst)
2013 - 1899.875 to 1902. (fgChargeHiGainLast)
2014 - -100.25 to -99 (fgChargeLoGainFirst)
2015 - 899.75 to 901. (fgChargeLoGainLast)
2016 Introduced new limits:
2017 - fgNumLoGainBlackoutLimit: 0.05
2018 - fgLoGainBlackoutLimit: 3.5
2019 - fgLoGainPickupLimit: 3.5
2020
2021 - callisto: The handling of automatic weights for the digital filter
2022 has been improved. There are now new calibration weights special
2023 for Monte Carlo calibrations.
2024
2025 - callisto: Updated Muon scale with latest results (1% difference
2026 for most data, 5% for Mar/Apr'05)
2027
2028 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2029 was saturated and the blackout-events in the low-gain exceed the
2030 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2031 This excludes those pixels which have a saturating high-gain
2032 channel, but the low-gain switch does not switch often enough
2033 to make the distribution reliable.
2034
2035 - callisto: fix a bug counting the number of saturated events. Up to now,
2036 the number of saturated slices was counted (which is one for a not too
2037 high number), but for some (pathological) pixels, many more slices
2038 saturated and produced wrong limits.
2039
2040 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2041 + MCalibrationRelTimeCam.CheckFitResults: Yes
2042 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2043 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2044 + MCalibrationRelTimeCam.CheckOscillations: Yes
2045
2046 - callisto: introduce max. number of events for intercalibration,
2047 the rest gets skipped. Default: 4096
2048 The calibration causes too many un-reliable pixels if more
2049 than about 5000 events are treated (@500 Hz) because of the
2050 mode hopping of the VCSels. However, in the past, some
2051 calibration runs have been taken (erroneously) with more
2052 than 5000 events, especially the intensity scans where
2053 a good precision is needed.
2054
2055 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2056 photo-electrons for the spline extractor by 1-2% (correctly).
2057
2058 - callisto: The intercalibration is now done using a full f-factor
2059 method instead of a simple update. This makes things slower but
2060 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2061 changes.
2062
2063 - callisto: MPedestalY3 now uses the same extraction range as the data
2064 as calculated by MPedestalY2
2065
2066 - callisto: A check of the fraction of allowed unsuitable (10%) and
2067 unreliable (30%) pixels has been addded when the conversion is
2068 calculated from interleaved events
2069
2070 - star: fixed a bug which caused MEffectiveOnTime containers not to
2071 be written. In the worst case they were skipped almost all, in the
2072 best case they were all ok. It depends on how often the new value
2073 was assigned just with an event which was skipped later by another
2074 task
2075
2076 - star: new histograms MHPointing and MHRate
2077
2078 - star: New tab (Currents) displaying the time evolution of the mean
2079 DC currents
2080
2081 - star: New tab (MeanRms) displaying the time volution of the mean
2082 Pedestal Rms
2083
2084 - star: Output now contains MReportStarguider
2085
2086 - star: Improved muon analysis. Due to the absense of a constant
2087 for the gaus fit for arc width and the fact that the arcwidth
2088 plot was a histogram instead of a profile the resulting psf
2089 became pedestal rms dependant
2090
2091 - ganymed: added new plot (MHPhi) for wobble mode as described in
2092 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2093
2094 - ganymed: corrects now (correctly?) for the misspointing in
2095 May/April 05
2096
2097 - ganymed: Two new default templates for ganymed.rc are avilable:
2098 ganymed_onoff.rc and ganymed_wobble.rc
2099
2100 - ganymed: The first version of MFMagicCuts has been released
2101
2102 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2103
2104 - ganymed, sponde: There are two new options to determin the number
2105 of bins for the signal region (NumBinsSignal) and the number of
2106 total bins (NumBinsTotal) in the MHThetaSq histogram
2107
2108 - ganymed: optimized palettes for MHDisp
2109
2110 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2111 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2112 sqrt(2) to large
2113
2114 - ganymed: The false source plot (MHDisp) is now based on Disp
2115 and a background model determined in the first loop is
2116 subtracted
2117
2118 - ganymed: MFMagicCuts are now available in the cvs. The correct
2119 solution for the disp ambiguity problem is now calculated using
2120 the third moment. The third moment cut therefor is skipped.
2121
2122 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2123 already determined by the third moment along the major axis and
2124 so its actual sign is aligned along the major axis of the shower.
2125
2126 - ganymed: If starguider data is available it is taken into account
2127 when calculating the source position. This is especially important
2128 for wobble data at high zenith angles and culmination data.
2129
2130 - ganymed: If available the starguider data is taken into account as
2131 good as it is possible without a starguider calibration. To switch
2132 it off add
2133 MPointingDevCalc.MaxAbsDev: -1
2134 to your ganymed.rc
2135
2136 - sponde: the zenith angle distribution is now weighted instead of
2137 choosen by default. This gurantees higher statistics in the highest
2138 and lowest energy bins. To switch this behaviour off use...
2139
2140 - sponde: now automatically displays the energy threshold
2141
2142
2143
2144 *** Version 0.9.3 (2005/06/03)
2145
2146 - general: MMcEvt now derived from MMcEvtBasic which should
2147 have no influence on compatibility with older camera files
2148
2149 - general: Implemented a new option to MReadReports which allows
2150 to force reading of the first event of some trees (eg. Drive-tree)
2151 before any other tree.
2152
2153 - general: Made a fix to MPointingPosCalc which assumes that the
2154 run-type is real-data if Process is called before ReInit, such
2155 that also the very first Drive-events in a run are treated
2156 correctly.
2157
2158 - shoplot now displays the filename in the title bar of the window
2159
2160 - merpp: new options: --auto-time-start --auto-time-stop which
2161 allow to cut updating with slow-control at the start- or
2162 (previousle --auto-time only allowed: and) stop-time of
2163 the run stored in the runheader.
2164
2165 - callisto: changed default of fgFallTimeHiGain in
2166 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2167 already set as default in callisto_Dec04Jan05.rc
2168
2169 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2170 now changes the filename for new weights automatically for
2171 cosmics, MC and for different calibration colors.
2172
2173 - callisto: a problem with the order of some code cause the
2174 name of the weights file in MPedestalY2 to be ignored.
2175 Wrongly the calibration_UV weights were used instead
2176 of the cosmics weights set in callisto.rc.
2177
2178 - callisto: should allow ct1 pulser data when the color is
2179 explicitly set also for pretty new runs
2180
2181 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2182 to introduce an additional scale factor (should be around 1)
2183 to adapt for slight deviations in different extractors from
2184 the MC calibration. For MC calibrations the scale factor
2185 is fixed to 1
2186
2187 - callisto: MFCosmics should handle very high signals a bit
2188 more accurate now
2189
2190 - callisto: when calculating the mean pedestal rms for different
2191 pixel sizes or sectors also kUnsuitableEvt is now taken into
2192 account - not only kUnsuitableRun
2193
2194 - callisto: '-raw' option is now the default
2195
2196 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2197 This has the advantage that mean values in the calibration (eg
2198 arrival times) are calculated more accuratly.
2199
2200 - callisto: In the resource file callisto_Dec04Jan05.rc
2201 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2202
2203 - callisto: new Hi-/Lo-Gain intercalibration constants
2204 hilocalib_sp1.root and hilocalib_sp1_mc.root
2205
2206 - callisto: changed default for MJPedestalY2.MaxEvents
2207 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2208
2209 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2210 has changed from 9.0 to 6.0. This is necessary to exclude two very
2211 ringing pixels in September which - when kept - destroy the image
2212 cleaning around them (Markus G.)
2213
2214 - callisto: (!) The Muon analysis of all data taken so far has
2215 suggested that different extractors give slightly different
2216 absolute results after calibration, due to there different
2217 handling of the calibration- and cosmics pulse shape. Although
2218 the over all calibration seems to be a bit to pesimistic (or
2219 the MC seems to be a little bit - 3-5% - too much attenuated).
2220 There for correction factors have been introduced which correct
2221 the calibration constants by
2222 0.956937799 for Digital Filter (callisto.rc)
2223 and
2224 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2225 calibration. The main advantage is, that both data types can
2226 be easily analysed together and compared to the same MC sample.
2227 The factors are choosen such, that the reference is now a
2228 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2229
2230 - star: fixed a bug which caused the first bin of the histograms
2231 vs time to disapear in PostProcess. This gave wrong results
2232 on the screen. The output and all following programs not
2233 directly accessing the histograms haven't been affected
2234
2235 - star, ganymed: Made sure that always the first Drive-tree event
2236 is read and Processed before the first data event was read.
2237
2238 - ganymed: implemented the possibility to replace the standard
2239 false source plot with a different one. For example: If
2240 you want to use a Disp based FS plot use the resource:
2241 NameHistFS: MHDisp
2242 For details about the requirements of these plots look
2243 at the corresponding classes
2244
2245 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2246 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2247 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2248 case MAlphaFitter is setup correctly. For On-Only optimization
2249 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2250 RunOn() instead of Run(). For energy estimation MJOptimize
2251 has been replaced by MJOptimizeEnergy
2252
2253 - sponde: The input MC spectrum can now be weighted to fake a
2254 different spectrum. This is done via MMcSpectrumWeight. For
2255 more details see the class description and sponde.rc
2256
2257 - sponde: The paremeter comparsion plots are not scaled by
2258 their entries anymore. Instead the MC plot is scaled by using
2259 the result spectrum of the analysis. If the input MC spectrum
2260 and the result spectrum has different slopes the absolut
2261 normalization is normally wrong.
2262
2263
2264
2265 *** Version 0.9.2 (2005/05/20)
2266
2267 - general: Changed the default paths for calibrated data and image
2268 files. (The implemented access to these files doesn't yet exist)
2269
2270 - general: support for MRunIter has been removed from the job classes
2271 (use the setter functions of MSeqeunce instead)
2272
2273 - general: ProcessFile has been renamed to Process in all job classes,
2274 because ProcessFile is missleading
2275
2276 - general: The storage of the palette in MHCamera is now possible
2277
2278 - general: new bits describing unsuitable and unreliable pixels have
2279 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2280 kDeadPedestalRms, kFluctuatingArrivalTimes
2281
2282 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2283 versions newer than V200404070
2284
2285 - general: support for cc file versions newer than V200504130. Added
2286 support for active loads (MCameraActiveLoad) and central pixel
2287 (MCameraCentralPixel)
2288
2289 - general: added new histograms for image parameters versus size
2290 (MHVsSize)
2291
2292 - general: The eventloop now automatically calls PrintStatistics
2293
2294 - Status Display: Improved support for printing:
2295 + A default can now be set in .rootrc (for more details see
2296 MStatusDisplay::PrintPS)
2297 + A print dialog is opened so that printer and command line
2298 can be canged
2299
2300 - showlog: improved such that it handles different verbosity levels
2301 more accurate now. This mean you can suppress output when
2302 using showlog.
2303
2304 - showplot: improved
2305 + The new graphics formats have been implemented
2306 (pdf, svg, png, jpg and xpm)
2307 + Implemented an interface for printing. Because you can change
2308 the printing command from the command line you can use all
2309 the nice postscript tool. To print a booklet for example call:
2310 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2311 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2312 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2313
2314 - callisto: fixed a bug in the recognition of the calibration bit
2315 pattern. Concerns only intensity calibration. (The strength of the
2316 intensity has been updated in some cases)
2317
2318 - callisto: add a filter against PIN Diode events when running over
2319 calibration runs since some of the recent calibration runs have
2320 been taken with Pin Diode.
2321
2322 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2323 39943, 44833 in the calibration (MCalibColorSet)
2324
2325 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2326 been set to 1e-18 in callisto_Dec04_Jan05.rc
2327
2328 - callisto: in callisto_Dec04Jan05.rc: set value for
2329 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2330 statistics for the calculation of the mean pulse time
2331 of the cosmisc
2332
2333 - callisto: the charge limit in the calibration has been raised
2334 from 2.5 to 4.5
2335
2336 - callisto: new setup read from callisto.rc
2337 + MCalibCalcFromPast.fNumEventsDump
2338 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2339 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2340
2341 - callisto: MExtractTimeAndChargeSpline extractor:
2342 + The integration ranges were shifted by 0.2 FADC slices to the right.
2343 + unreliable handling of floating point values caused different
2344 results on different platform or with different compiler options:
2345 The new algorithm is numerically exact and more accurate because
2346 it doesn't calculate the integration position by multiple times
2347 adding the step-size (which results in numerical uncertanties
2348 exspecially if multiplied with large numbers)
2349 + A lot of fixes have been introduced which effects integrating the
2350 spline at the edges of the valid range. In this case any memory
2351 was randomly accessed. This behaviour can be tested replacing
2352 all MArrayF by TArrayF which perform a range check (but of course
2353 they are a lot slower)
2354 ! No result obtained with the Spline before can be trusted! Due to
2355 random memory access it might by completely random!
2356
2357 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2358 + extraction range in the high gain to 4.
2359 + weights file to cosmics_weights46.dat
2360
2361 - callisto:
2362 + introduce the check for fluctuating arrival times.
2363 + set charge limit to from 2.5 to 4.5
2364 + introduce asymmetric exclusion due to "deviating number of phes":
2365 Default: -9.0 +4.5
2366 + make deviating number of phes unsuitable (see David's findings).
2367
2368 - callisto: fixed the display of unsuitable pixels. The old change
2369 to a real profile in MHCamera broke it.
2370
2371 - callisto: The cosmics filter is used in MJCalibration now
2372 independant of the pulser color (formaly it was used only for
2373 CT1-pulser data). The threshold of number of max empty pixels
2374 has been raised from 2% to 5% in MJCalibration. The maximum
2375 fraction of rejected event is 50% otherwise the calibration has
2376 failed. The filter now ignores unsuitable pixels.
2377 Setup the filter from callisto.rc using "ContCosmics"
2378 (see MFCosmics::ReadEnv)
2379
2380 - callisto: changed default for fgOffsetFromLogain back
2381 from -2.8 to -1.8 in digital filter.
2382
2383 - callisto: for the common extractors
2384 + MExtractFixedWindow
2385 * MExtractTimeAndChargeSlidingWindow
2386 * MExtractTimeAndChargeSpline
2387 * MExtractTimeAndChargeDigitalFilter
2388 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2389 and fResolutionPerPheLoGain
2390
2391 - callisto: Updated the hi-/lo-gain intercalibration constants
2392 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2393 hilocalib_df6.root
2394
2395 - callisto: The default lo-gain extraction window for the
2396 MExtractTimeAndChargeSlidingWindow extractor has been increased
2397 from 6 to 8 to take the stretch of the pusle into account
2398
2399 - callisto (!!!): fixed an important bug in the setting of the
2400 incoming pedestal pointer to the signal extractor extracting
2401 pedestals. This bug caused the pedestals not to be subtracted
2402 correctly in the calibration afterwards. The effect was about 10%
2403 too high conversion factors for the digital filter and the spline
2404 and more than 40% for the sliding window.
2405 The bug existed since end of February! (Markus G.)
2406
2407 - star: added muon support to star. A new tab "MHMuonPar" is
2408 displayed. The lower right plot is an estimate of the point spread
2409 function. A reference value is displayed. To get the real PSF
2410 you must compare with MC. The setup for the muon analysis
2411 is done in star.rc. More informations can be found in
2412 MHSingleMuon and MHCalibParCalc
2413
2414 - star: The weather data is now displayed in star
2415
2416 - star: MEventRateCalc handles the calculation of the event rate more
2417 accurate now in case of the start of a new run inside a sequence
2418
2419 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2420 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2421 changed only minimally
2422
2423 - ganymed: (MJCut and MJOptimize) now displayes the number of
2424 excess events versus size. The energy estimation is done in
2425 MJSpectrum (sponde)
2426
2427 - ganymed: got support for using other variables than Alpha, eg. Theta.
2428 Therefor you need a class deriving from MHAlpha which supports
2429 this variable (one is already existing: MHTheta, which is now the
2430 default in ganymed). It is setup through ganymed.rc
2431
2432 - added a full featured spectrum program (sponde) which reads
2433 ganymed output and monte carlos and compiles a spectrum
2434
2435
2436
2437 *** Version 0.9.1 (2005/04/14)
2438
2439 - Fix bug on the arrival time reconstruction when using Digital
2440 Filter (in some marginal cases (10%) times were reconstructed shifted
2441 by 0.2 slices)
2442
2443 - all executables now return 2 where in previous versions -1 has
2444 been returned (gave problems with shell-scripts)
2445
2446 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2447 also done with a intercalibration input file
2448
2449 - a bug in the time fine adjustment of the digital filter has been fixed
2450
2451 - a lot of small fixes to calling TPad::Divide with a margin==0
2452
2453 - MStatusDisplay now shows the memory usage
2454
2455 - added a memory leak statistic after the eventloop
2456
2457 - MHadronness replaced by MParameterD
2458
2459 - MEnergyEst replaced by MParameterD
2460
2461 - wobble mode can now be switched on from the data-set
2462
2463 - switched on bad pixel detection for a pedestal level
2464 which is more than 5 times the variance
2465
2466 - Fixed default paths to be correct for the new data center
2467
2468 - Fixed handling of drive data. The pointing position in now
2469 copied to MPointingPos inside star for real and MC events
2470
2471 - made sure, that the sequences in a dataset are sorted by
2472 their number to ensure the correct synchronization
2473
2474 - added all resource files necessary to handle spline extraction
2475 of signal for the late 2004 and the early 2005 data
2476
2477 - update the reference lines for the december data
2478
2479 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2480 This is important for the Dec. and Jan. data where the calibration
2481 pulse position changes much.
2482
2483 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2484 filter. This corrects only an defective extraction of the MC at
2485 low-gain signals lower than 90 phes.
2486
2487 - fixed some slowdown in calibrating data with interleaved events from
2488 Jan and Dec. As a workaround made the pretty palette the default.
2489 The inverse Deep Blue Sea has a bug which slows down long calibration
2490 runs a lot.
2491
2492 - implemented new values from new starguider report as defined
2493 in TDAS00-07 V7.1 (eg SkyBrighness)
2494
2495 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2496 in starguider report (If you merpp the same reports with this version
2497 you'll get the correct units (arcmin) but a different result
2498 than with old versions (wrong units))
2499
2500 - Now the status display can also write PNG, JPEG and XPM (other file
2501 formats are still unsupported by root)
2502
2503 - added a lot of scripts and macros in directory datacenter used
2504 for automatic processing
2505
2506
2507
2508 *** Version 0.9 (2005/03/23)
2509
2510 - Calibration is now done autmatically into photo-electrons like
2511 decided by the Collaboration Board
2512
2513 - Reference lines in the display can be read from resource file
2514
2515 - Interlaced calibration events can be handled by callisto
2516
2517 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2518 and applied in callisto.
2519
2520 - class MJCalibTest can be called by callisto
2521
2522 - callisto can now run with three data types: rawdata, rootdata, MC
2523
2524 - added two classes mreport/MReportStarguider.cc and
2525 mreport/MReportStarguider.h for implementing starguider-data
2526
2527 - the output of merpp-update now contains starguider information:
2528 MReportStarguider and MTimeStarguider
2529
2530 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2531 values were lower than they should. This was more visible for high
2532 energy (Size) events.
2533
2534 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2535
2536 - added a new loop to callisto to support the correct extraction of
2537 the pedestal and pedestal rms through the signal extractor
2538
2539 - added class to perform fourier tranformation of a hexagonal structure
2540 (MHexagonalFT)
2541
2542 - added class to perform fourier tranformation of a hexagonal structure
2543 in a tasklist (MHexagonalFTCalc) example: hft.C
2544
2545 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2546 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2547 small pixels, example: extendcam.C
2548
2549 - added possibility to write data to memory (TTree) using MWriteRootFile
2550
2551 - added possibility to read a TTree stored only in memory by MReadTree
2552
2553 - new classes to deal with the interleaved calibration events:
2554 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2555
2556 - implemented filters to callisto to skip calibration events
2557
2558 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2559 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2560 the slices by statistics
2561 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2562 signal extractor without randomization
2563 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2564 with the signal extractor with randomization (extraction window is
2565 randomly fixed)
2566 The three kind of pedestal is not yet implemented (for speed reasons) as
2567 long as nobody really needs it:
2568 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2569 extracted with the signal extractor with randomization
2570
2571 - callisto now finds the pulse position in the data automatically
2572
2573 - implemented data reduction in calibrated data by reducing the precision
2574 of the stored floating point values (pedestal, rms and signal) to
2575 roughly 0.5%
2576
2577 - fixed showplot to make file format conversion (eg. converting a
2578 status display stored in a root file into a postscript file) in
2579 batch mode possible:
2580 showplot -b --save-as-ps[=outfile.ps] infile.root
2581
2582 - Allow class names as part of filter rules, eg
2583 (MFSupercuts) && (MHillas.fSize>100)
2584
2585 - fixed a lot of stuff to allow all programs to process MonteCarlo
2586 camera files.
2587
2588 - enhanced possibility to debug reading of resource file
2589
2590 - MDataChain should handle priorities of operator more
2591 accurate now
2592
2593 - completely revised the container in which the signal is stored
2594 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2595 * the new implementation is faster and
2596 * needs less storage space
2597
2598 - FIRST version which can process Monte Carlos through the
2599 whole chain of programs (callisto, star, etc)
2600
2601 - implemented new image parameters for the border length of
2602 the shower image (MNewImagePar2)
2603
2604 - implemented wobble-mode in ganymed
2605
2606 - new class (MJOptimize) taking care of all optimization processes
2607
2608
2609
2610 *** Version 0.8.6 (2004/10/05)
2611
2612 - New combined signal and time extractor
2613 MExtractTimeAndChargeDigitalFilter
2614
2615 - The Report for the trigger section in the CC run summary has been
2616 updated, and now the IPRs (Individual Pixel Rates) are available.
2617
2618 - new macros for database interaction: filldotrun.C, filldotrbk.C
2619
2620 - added new program which can convert colored output which was redirected
2621 into a file back into colored text (for example to display it with
2622 more): showlog
2623
2624 - added new program to display an MStatusArray of plots (stored with
2625 MStatusDisplay) from a file: showplot
2626
2627 - Added support for Sequences (MSequence). Sequences are blocks of run
2628 files containing the same calibration and belonging to the same
2629 source
2630
2631 - Added a new task (MTaskEnv) which can be used in setup files to switch
2632 between different tasks (for example to choose a signal extractor)
2633
2634 - Implemented automatic file splitting in MWriteRootFile
2635
2636 - After image cleaning an island index is assigned to all used pixels.
2637 The index corresponds to the order of the islands in size.
2638
2639 - added a cleaning which takes signal height _and_ arrival time into
2640 account: probability cleaning (for more details see MImgCleanStd)
2641
2642 - added a cleaning which takes takes the absolute number of photons
2643 times the area ratio as cleaning level
2644 (for more details see MImgCleanStd)
2645
2646 - Changed calculation of image parameters such, that it can be done
2647 for all used pixels or the pixels with a defined island index only
2648
2649 - implemented new image parameters displaying the number of islands,
2650 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2651
2652 - event display in executable changed to support also calibrated files
2653 (done with MJCalibrateSignal)
2654
2655 - added program doing the calibration and the signal extraction
2656 and signal calibration: callisto Most part of the setup is done
2657 by a resource file: callisto.rc
2658
2659 - implemented support for pixels with negative IDs (Raw file format
2660 version 4)
2661
2662 - implemented an new option in merpp (--auto-time) to get the time
2663 range for cc and/or caco data from the run header of the raw data
2664
2665 - New star-program (star and MJStar). Taking calibrated data from
2666 callisto/MJCalibrateSignal as input. The setup is done through
2667 a resource file: star.rc
2668
2669 - Added possibility to setup the eventloop in the mars-executable
2670 Camera Display by a resource file: mars.rc
2671
2672 - The the mars-executable Camera Display can now also read
2673 calibrated data files written by callisto/MJCalibrateSignal
2674
2675 - Added a new class which can calculate the source position in
2676 the camera from a pointing model known to be correct and
2677 the pointing model used for observations (MSrcPosFromModel)
2678
2679 - added a new version of the class calculating the effective on-time
2680 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2681 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2682 MHTimeDiffTheta.
2683
2684 - added the possibility to count how often a signal is above (or
2685 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2686 can replace MHTriggerLvl0)
2687
2688 - added ore convinient ways to set the axis-titles of your histograms
2689 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2690 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2691
2692
2693
2694 *** Version 0.8.5 (2004/08/06)
2695
2696 - new Signal Extractors: MExtractFixedWindowSpline
2697 and MExtractAmplitudeSpline
2698
2699 - implementes interleave in merpp to be able to merpp parts of a file
2700
2701 - implemented force-functionality to merpp
2702
2703 - star display to display star catalogs (MAstroCatalog)
2704
2705 - star display to 'mirror' stars to the camera (MAstroCamera)
2706
2707 - implemented a new cleaning option which allows cleaning scaled with
2708 the real ratio of the rms depending on the pixel size, not only the
2709 square root of the pixelsize (MImgCleanStd, MCameraData)
2710
2711 - removed obsolete MBlind* classes
2712
2713 - Signal extractor taking the AB flag into account implemented (this makes
2714 an odd number of slices for signal extraction possible
2715 (MExtractSignalABcorr)
2716
2717 - implemented a class extracting the pedestal from the raw-data (events)
2718 itself using empty lo-gain (MpedCalcFromLoGain)
2719
2720 - Added mean values to MPedPhotCam
2721
2722 - Added Makefile for Darwin (this OS is NOT officially supported!)
2723
2724
2725
2726 *** Version 0.8.4 (2004/04/19)
2727
2728 - new fast arrival time extractor using cubic splines:
2729 MExtractTimeFastSpline
2730
2731 - implementes multi-argument support in MDataChain
2732 ("pow(a, b)")
2733
2734 - implemented double reference support in MDataChain
2735 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2736
2737 - added support in MF for expressiond like
2738 "MHillas.fWidth<2*<MHillas.fLength"
2739
2740 - MDataChain is now able to support variables like [0], [1], ...
2741 which can be used in fit functions as parameters. The interface
2742 is implemented through the new virtual function
2743 MParContainer::SetVariables
2744
2745 - added new class MArrivalTimeCam/MArrivalTimePix:
2746 Storage containers to hold the ArrivalTime of the camera/pixel
2747
2748 - added new classes for the calibration of relative arrival times:
2749 MCalibrationRelTimePix and MCalibrationRelTimeCam
2750
2751 - added new classes to extract the signal of the blind pixel and the
2752 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2753
2754 - added new classes for the bad-pixels treatment (MBadPixels*)
2755 which are more powerfull than the old ones (MBlindPixel*)
2756 and will replace them.
2757
2758 - added filter against cosmics: MFCosmics
2759
2760 - added new class MArrivalTimeCalc2:
2761 Calculates the arrival time as the signal weighted mean of the time
2762 slices in the maximum window
2763
2764 - added a new macro call pointspreadfucntion.C that fits with a 2D
2765 gaussian the DC spot for an star. It gives you the RMS of
2766 the PSF and the center of the star, very useful for misspointing
2767 studies.
2768
2769 - added support for multi-telescope camera files. Added classes
2770 MStereoCalc and MStereoPar, classes to calculate and store shower
2771 parameters calculated from the data of two telescopes, for the MC
2772 studies regarding the MAGIC clone.
2773
2774 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2775 MC data calibrated in photons instead of ADC counts.
2776
2777 - added three macros to show the calibration and analysis chain of
2778 MC data. The macro starmc.C does both calibration and analysis, producing
2779 an output containing Hillas parameters for each event. The macro
2780 mccalibrate.C does just the calibration and writes out a file containing
2781 pixel information in photons instead of FADC data. The macro starmc2.C
2782 reads in such a file and produces an output with Hillas parameters.
2783
2784 - added MPedPhotCalc to compute pedestals in units of photons, see
2785 macro pedphotcalc.C
2786
2787 - added all class to perform the calibration, see macro calibration.C
2788
2789 - added class MFFT to perform Fast Fourier Transforms
2790
2791 - added class MSimulatedAnnealing to perform simulated annealing
2792 minimizations
2793
2794 - added new macro bootcampstandardanalysis.C which holds the skeleton
2795 of the analysis chain discussed in the december bootcamp.
2796
2797 - added support for DAQ raw data file format V2
2798
2799 - implemented an arbitrary time stamp for the events from raw-data
2800 files with file version<3. It is calculated from the run number,
2801 the date of start and the FADC clock tick from the first module
2802
2803 - implemented the correct decoding of the event time-stamp
2804 coming from the DAQ for raw-data files with file-version>2
2805
2806 - added a new classes storing the pedestals in units of photons:
2807 MPedPhotPix, MPedPhotCam
2808
2809 - added support for DC current files from the camera control
2810
2811 - added support for start- and stop-time when merpping report files
2812
2813 - added MReportCC storing the weather data from the CC-REPORT
2814
2815 - added class to fill trainings and test matrices (MTFillMatrix)
2816
2817 - added a filter performing a software trigger (MFSoftwareTrigger)
2818
2819 - Added classes to perform parts of the standard analysis (Jobs):
2820 + MJPedestals
2821 + MJCalibration
2822 + MJExtractSignal
2823 Note: All of them are preliminary!
2824
2825 - Added Iterator to iterate over files giving only the run-number
2826
2827 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2828 the evolution of a sector vs time
2829
2830
2831
2832 *** Version 0.8.3 (2003/12/05)
2833
2834 - adapted Random Forest classes to allow the use with MC
2835 multi-telescope files which can be produced with the coming
2836 camera version 0.7.
2837
2838 - added classes to read and interprete central control report files
2839 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2840
2841 - enhanced merpp (the executable) to support .raw and .rep files.
2842
2843 - added classes for light calibration (MCalibration* and
2844 MHCalibration*) by Markus Gaug. Further work has to be and will
2845 be done soon.
2846
2847 - Added a preliminary 'synchronizer' (MReadReports) which will
2848 replace MReadMarsFile as soon as it is finished.
2849
2850 - Added a tutorial macro demonstrating how report files are merpped
2851 and how they can be read from the root file in the correct order
2852 of time (readrep.C)
2853
2854 - Added a generalized histogram (similar to MH3) called MVsTime
2855 which allows to plot variables (or rules - MDataChain - of
2856 variables) vs time. For an example have a look at tempvstime.C.
2857
2858 - Changed the name of the event trees:
2859 + Events --> Events
2860 + PedEvents --> Pedestals
2861 + CalEvents --> Calibration
2862
2863 - changed name of MTime in the event trees from MRawEvtTime to MTime
2864
2865 - added displaying the sector indices to the mars event display
2866
2867 - Magic Online Analysis (MOnA) implemented in a first version
2868 (see mona.cc, MOnlineDump and MOnlineDisplay)
2869
2870 - added classes to calculate event rate
2871 (preliminary: MEventRateCalc, MEventRate)
2872
2873 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2874
2875 - added classes dealing with the telescope pointing position (MPointing*)
2876
2877 - implemented the 'final' Mars time stamp based on some experiences with
2878 the new 'Synchonizer'
2879
2880
2881
2882 *** Version 0.8.2 (2003/11/10)
2883
2884 - accelerated standard analysis by a factor of 6-8 ...
2885 + doing precalculations in MGeomCam for the pixel area ratio
2886 + creating a look up table for the single pixels in MCerPhotEvt
2887
2888 - added task to calculates weights in case you want to 'change'
2889 the energy spectrum of a monte carlo file
2890 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2891
2892 - added a new executable star which implements the
2893 star.C macro as precompiled executable. Currently a flexible
2894 setup is not possible, but a 'input card' setup will follow.
2895
2896 - Starting to implement Multi-Telescope-Support based on the
2897 upcomming camera version 0.7. The base for a general support
2898 is implemented and the star-functionality is proven to work.
2899
2900 - Replaced Event-Display in and Camera-Display in the Mars GUI
2901 executable by a more convinient display base on MStatusDisplay.
2902
2903 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2904
2905
2906
2907 *** Version 0.8.1 (2003/10/20)
2908
2909 - added signal subtraction for pure on data by means of fitting
2910 the background in the off region or by performing a combined
2911 signal/background fit. Provides necessary histograms for
2912 obtaining energy spectra and a light curve.
2913
2914 - added classes to perform and study the selection of the
2915 2nd Level Trigger on MC data (example in triglvl2.C macro)
2916
2917 - added pedestal calculation
2918
2919 - implemented "democratic cleaning" (tail cut value proportional
2920 to pixel area) according to Wolfgang's suggestion.
2921
2922 - added Sigmabar treatment (calculation and basic histogramming)
2923
2924 - added basic routines to apply padding
2925
2926 - added first implementation of MARS-based source visibility plotter
2927 (needs to be linked against slalib, preliminary version)
2928
2929 - enhanced functionality of data chains: random numbers, conversion
2930 functions and access to MHMatrix objects
2931
2932 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2933 numbers under certain circumstances (runs with 0 events included)
2934
2935 - fixed a bug in the general filter MF (didn't work on some systems
2936 at all)
2937
2938 - fixed a bug in chaining files, which caused the analysis to crash or
2939 ignore files
2940
2941 - implemented more geometry classes describing the parameters used
2942 to simulate the PMT camera
2943
2944 - added new Monte Carlo classes containing the setup of the different
2945 programs in the MC chain.
2946
2947 - added a (preliminary) general task to evaluate chi-square of a given
2948 parameter in an eventloop.
2949
2950 - first implementation of a container describing the observatory
2951 location (Long, Lat, etc)
2952
2953 - added Random Forest - method for g/h-separation
2954
2955 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2956 (this means, that it is compiling, but not yet fully tested)
2957
2958 - added a new status display which can show the present status
2959 of histograms while an eventloop is running (MStatusDisplay,
2960 an example can be found at status.C)
2961
2962 - reorganized directories:
2963 classes describing the image --> mimage
2964 classes containing Monte Carlo Histograms --> mhistmc
2965 classes for Random Forest method --> mranforest
2966
2967 - added (event-)weights to fill histograms
2968
2969 - colors in logging output to screen
2970
2971 - changes to the Image Parameter declaration:
2972 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2973 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2974 + MHillasExt now derives from MParContainer instead of MHillas
2975 --> Files written with the old definition are more or less unreadable
2976
2977 - reading of reflector files
2978
2979 - display data from reflector files in the camera
2980
2981 - implemented currents (and display them in the camera)
2982
2983 - logarithmic scale in camera
2984
2985 - added class to iterate through directory contents (MDirIter)
2986
2987
2988
2989 *** Version 0.8 (2002/11/18)
2990
2991 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2992
2993 - corrected 48(!) wrong entries in the Next Neighbor table of the
2994 Magic Camera (all in the inner part of the outer ring, mostly
2995 missing a single NN)
2996
2997 - Fixed a bug in the table describing the Next Neighbours of the
2998 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2999 have any neighbour)
3000
3001 - changed trigrate.C: now it calculates the pure NSB triggers from
3002 a camera file (generated with no showers), so there is no need
3003 to introduce them by hand in the BgR array (for more details
3004 please ask Abelardo)
3005
3006 - added MHHadronness (and MHadronness) as a general facility to evaluate
3007 the quality of a gamma-hadron seperation method
3008
3009 - changed MWriteAsciiFile to accept rules (MDataChain)
3010
3011 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3012 must be replaced by calles to MWriteAsciiFile::AddColumn and
3013 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3014 changed.
3015
3016 - Implemented generalized event-matrices (one row per event)
3017 (MHMatrix)
3018
3019 - implemented the one dimensional composite probabilities
3020 (MHCompProb, MCompProbCalc, comprob.C)
3021
3022 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3023 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3024
3025 - Added a camera display displaying the pixel numbers to the
3026 event display gui.
3027
3028 - Added Monte Carlo Informations to event display gui
3029
3030 - Changed the camera display to display the pixel numbering
3031
3032 - Added three buttons to the camera display to change the palette
3033
3034 - Added the number of used and core pixels after image cleaning
3035 to MHillas
3036
3037 - Changed the algorithm used in MHillas according to TDAS 02-03
3038
3039 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3040
3041 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3042
3043 - Added fCosDeltaAlpha to MHillasSrc
3044
3045 - The numbers of photons used to calculate fConc and fConc1 in
3046 MHillasExt are now scaled with the pixel size, so that one get
3047 a four times smaller value for the bigger pixels in the outer ring.
3048
3049 - added new task to smooth the camera contents (MCameraSmooth)
3050
3051 - added possibility to use interpolated pixel values for blind pixels
3052 instead of removing it completely from the analysis
3053
3054 - Implemented the possibility to save the whole eventloop with
3055 its setup to a file. This information can be read and from
3056 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3057 and MEvtLoop::MakeMacro. If you find something not working, please
3058 report - this stuff is still in a beta phase.
3059
3060 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3061 file having crab starfield, but also for all following files - fixed
3062
3063 - MTaskList::PrintStatistics can now be instructud to print also the
3064 title, too: use PrintStatistics(0, kTRUE)
3065
3066 - Changed the image cleaning so that pixels with to many 'used'
3067 neighbors are left used (to get rid of 'holes' in events)
3068
3069 - Introduced more output to the camera displays
3070
3071 - Added an array of histograms (eg one hist per run), MHArray
3072
3073 - Added a _preliminary_ version of the reader for CT1 PreProc files
3074 (MCT1ReadPreProc)
3075
3076 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3077 (thanks to Raquel)
3078
3079 - added the first energy estimator (MEnergyEstParam, estimate.C,
3080 estfit.C) using a parametrization
3081
3082 - Added some new Monte Carlo paremeter containers used to store
3083 setup information from the MC chain (MMcConfigRunHeader,
3084 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3085
3086
3087
3088 *** Version 0.7 (2002/04/30)
3089
3090 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3091 the pedestal mean value was saved incorrectly. For files from
3092 this versions we substract 0.5 from the pedestal mean.
3093 WARNING: This may effect your results, so don't wonder...
3094
3095 - First implementation of an algorithm using only triggered events
3096 for the collection area calculation
3097
3098 - Ascii Output can now also be used for parameter containers which
3099 doesn't overload MParCointainer::AsciiWrite
3100
3101 - The Ascii Output is now also capable of writing single data members
3102 of one container
3103
3104 - You are now able to change the order of the values written to the
3105 ascii file
3106
3107 - You can now specify a conversion factor for each data member written
3108 to an ascii file. This may be usefull to change the units of the
3109 data member (eg. degrees instead of millimeters in case of the
3110 hillas parameters)
3111
3112 - Replaced old MHillas by a new structure which allows you to extend
3113 the parameters stored in MHillas very easily:
3114 see MHillas and MHillasExt
3115
3116 - Added classes to handle source dependancy of image parameters:
3117 see MHillasSrc
3118
3119 - Added container (MBinning) to have a standard input for the binning
3120 in different histograms (eg. the Energy bins should be the same in
3121 all histograms)
3122
3123 - Changed Hillas histograms from mm to deg
3124
3125 - Added the flexible binning to the hillas histograms
3126
3127 - Added a filter for the alpha parameter (MFAlpha)
3128
3129 - It is now possible to write single data members of a class object to
3130 an output stream instead of the whole container only
3131
3132 - Added a generalized filter for a data member:
3133 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3134
3135 - Added a generalized Filter parser for more difficult filter rules
3136 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3137
3138 - Added new Monte Carlo histograms:
3139 MHMcEnergyImpact and MHMcEfficiency
3140
3141 - Added many new histograms needed for the flux calculation.
3142
3143 - Added a generalized histograms which can fill and show up to three
3144 data members in either a one-, two- or three-dimensional histogram, eg:
3145 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3146
3147 - Added:
3148 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3149 * calculation of <Theta> as a function of time (MHThetabarTime)
3150 they are needed in the flux calculation in
3151 order to select for a given bin in Theta (or time) the appropriate
3152 effective collection area, which is assumed to be given as a function
3153 of Theta and the true energy
3154
3155 - Added calculation of the migration matrix in the energy
3156 (MHMcEnergyMigration):
3157 the migration matrix describes the migration from the true (E_true)
3158 to the estimated energy (E_est); it is needed to determine the
3159 distribution of E_true from the measured distribution of E_est
3160 by unfolding
3161
3162 - changed the color palette in the camera display to DeapSea.
3163
3164
3165
3166 *** Version 0.6 (2002/01/15)
3167
3168 - Introduce the option of disable pixels (MBlindPixels and
3169 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3170 able to deal with Star Field NSB.
3171
3172 - Fixed a bug in the pedestals substraction
3173
3174 - Introduced verbosity levels
3175
3176 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3177
3178 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3179 work correctly (thanks to Abelardo)
3180
3181 - Introduced correct treatment of the diffuse Night Sky Background
3182 and NSB (MMcPedestalNSB)
3183
3184 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3185
3186 - Introduced MMcRunHeaders which contains monte carlo run informations
3187
3188 - Added a 'Print'-Task (MPrint) which calls the Print function
3189 of a parameter container for each event
3190
3191 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3192
3193 - changes to be more efficient with root 3.02/06
3194
3195 - root 3.02/06 fixes:
3196 + the memory leak when reading MRawEvtData
3197 + loosing more time than necessary to update the progress bar
3198
3199 - MWriteAsciiFile is now capable of writing more than one container
3200 in a line. For example: To be able to write Monte Carlo and
3201 Hillas values (energy and alpha) in one line.
3202
3203
3204
3205 *** Version 0.5 (2001/11/06)
3206
3207 - Added new GUI functionality (Analysis)
3208
3209 - Added a camera display to be able to display events in the camera
3210 together with the calculated hillas ellipse
3211
3212 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3213 object at any state of the analysis, so that the output are several
3214 states
3215
3216 - Fixed a bug in the collection area error calculation
3217 (Thanks to Ciro and Abelardo)
3218
3219 - Fixed a bug which causes merpp to crash in some environments
3220
3221 - Implemented auto enabling scheme for Branches to speed up reading
3222 a lot (see MReadTree and MTask)
3223
3224 - Fixed a bug in the Histogram classes which caused histograms to
3225 be written to a file by MWriteRootFile without request
3226
3227 - changed the object I/O from the old stylish root I/O to the new
3228 'auto evolution scheme' This was done only for classes which are not
3229 yet used in Monte Carlo files, so that these files are still readable.
3230
3231 - Added support for a progress bar in MEvtLoop and MReadTree
3232 (see the Analysis Window in Mars for an example)
3233
3234 - Fixed a bug in the package creation which disturbed the conversion
3235 between a mars version unpacked from a tar file and the repository.
3236
3237 - Changed the code to writer merpped (converted into root format)
3238 raw files, to get faster (around 10%)
3239
3240
3241
3242 *** Version 0.4 (2001/09/20)
3243
3244 - This release is made to compile on a root version >= 3.00
3245
3246 - Fixed a bug which causes MReadTree to read the first file only
3247
3248 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3249
3250 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3251
3252 - Added a task to write several container to a root file (MWriteRootFile)
3253
3254 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3255
3256 - Added calculation of the collection area (MMcCollectionAreaCalc)
3257
3258 - fixed some bugs in the Hillas calculation
3259
3260 - added filters to be able to control the task execution dependent on
3261 a parameter (for example: the number of level 1 triggers in a MC-file)
3262
3263
3264
3265 *** Version 0.3 (2001/04/23)
3266
3267 - Many demo macros added
3268
3269 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3270
3271 - Hillas Calculation added
3272
3273 - Standard image cleaning available
3274
3275 - MReadTree is now able to handle more than one file
3276 (Remark: of the same structure)
3277
3278 - Now we are able to display events in a first version of the
3279 Camera event display. To do this we must run the macro
3280 "macros/readCT1.C" to read data from CT1.
3281
3282
3283
3284 *** Version 0.2 (2001/01/24)
3285
3286 - First Implementation of a Gui to read the raw data. Start the
3287 gui with the command mars.
3288
3289
3290
3291 *** Version 0.1 (2000/12/20)
3292
3293 - First official release 0.1
3294
3295 - Changes:
3296
3297 + changed calling style of MRawPixelIterator from do...while to
3298 while-loop
Note: See TracBrowser for help on using the repository browser.