source: trunk/MagicSoft/Mars/NEWS@ 9463

Last change on this file since 9463 was 9463, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 134.9 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 * Added consistency check for two consecutive runs
11
12 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
13 has been disconnected and the L1 (L1TPU) has directly been connected
14 to another bit in the trigger pattern. This has been fixed by an
15 update of the decoding. Both bits are now or'ed together.
16
17 ;showplot:
18
19 * If a file without a MStatusArray is opened all object (not just
20 canvases) found in the file are drawn. Note that this may result
21 in empty tabs.
22
23 ;ceres:
24
25 * The night sky noise is now scaled with the sensitive area and
26 is given in units per square centimeter
27
28 * Added the possibility to add a cut after the image parameter
29 calculation (''Cut'')
30
31 * updated the PDE of the GAPDs with a more reliable curve from
32 the meeting page (linear extrapolate below 350nm)
33
34 * The impact distribution in the event distrbutions is now
35 perpendicular to Alt/Az and the histogram is displayed in 1D
36
37 * The GAPD PDE has been updated
38
39 * PDEs and mirror reflectivities have been linearily extrapolated
40 to match the wavelegth range between 290nm and 900nm
41
42 * There is no default pulse shape anymoe it must be given in
43 the resource file
44
45 * Fixed a bug which caused the aerosol coefficient to be incorrectly
46 initialized. The effect might be random but seems to be small.
47
48 * Now accepts sequence files as input
49
50 * creation of pedestal and calibration files is now steered by
51 --mode (see ceres help)
52
53 * Instead of initializing the whole G-APD chip (all cells) before
54 each event (which is rather time consuming) a time evolution before
55 each event is now simulated which is enough to recovere every cell
56 to 99.999% of its response taking the background rate into account.
57 This is in total about a factor of ten faster and should not be
58 less accurate because under normal conditions the recovering cells
59 and the newly hitten cells will hardly be identical (due to
60 statistical reasons)
61
62 * improved the trigger algorithm which is now faster and allows easily
63 for multiplicity triggers
64
65 * The PDC flag in the file name is now correctly written
66
67 * A "PreCut" has been added which can be used after reading the events
68 to select them even before any calculation is done.
69
70 ;merpp:
71
72 * The new drive reports which contain also the status of the starguider
73 are now implemented, but the starting date (17/05/09) is preliminary.
74
75 ;callisto:
76
77 * Fixed a bug which prevented MAGIC Monte Carlo file from being
78 calibrated (ceres files worked)
79
80 ;star:
81
82 * allow to run thru even if discriminator threshold are missing
83 (they are not used for analysis so far anyway)
84
85 ;ganymed:
86
87 * added new starguider calibration for sequences since 1000534
88
89 ;database:
90
91 * added possiblity to query/plot data from certain source (with
92 regular expressions) in plotdb.php
93
94
95
96== Version 2.3 (2009/03/07) ==
97
98 ;SUGGESTION
99
100 * There is no need to re-run any data because no change took place which
101 could have an effect on the output. However, if you want a
102 meaningful SrcPos plot for your MCs in sponde you must re-process
103 star for your MCs first.
104
105 ;REMARK
106
107 * File produced with this release containing a camera geometry (which
108 are basically all files were produced as default) will not be readable
109 by older releases.
110
111 ;general
112
113 * fixed a few small bugs which could cause the display to crash in ganymed
114 and sponde
115
116 * in sequence file the date can now be omittet. In this case the
117 leading date with the underscore is missing in the expected filename
118
119 * the geometry class now also supports other geometries than just hexagons
120
121 ;automation
122
123 * added magnetic field Azimuth direction (ARRANG), currently
124 at ~ -7deg at La Palma
125
126 ;database
127
128 * plotdb.php: added default (sequences) for startup, added possibility
129 to set size of plot
130
131 * added a new table ''RunDataCheck'' which containes the rates after
132 image cleaning for every run which succeeded star. It can be
133 plotted using ''plotrundb.C''
134
135 ;merpp
136
137 * added support for Arehucas Version >= 200812140
138
139 * added support for Arehucas Version >= 200809030
140
141 ;mars
142
143 * The display now also displays the trigger pattern
144
145 * The display can now display ceres reflector (_R_) files
146
147 ;ceres
148
149 * added a uniformly distributed one-bin time jitter for the start of the
150 digitization. Otherwise the first photon would be digitized always with
151 the same alignment to the bins
152
153 * Added a plot showing the production height of the photons
154
155 * Moved the particle id from the event header to the run header
156
157 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
158
159 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
160
161 * Added many new options to control the tasks. For deatils see ''ceres.rc''
162
163 * Removed obsolete plots in pedestal and calibration mode
164
165 * Removed the non-NightSky photons from the plots where they are just
166 disturbing
167
168 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
169
170 * The daq event number now represents the readout number
171
172 * The camera ''electronics'' can now be ''switched off''
173
174 * A new tab ''Info'' now display basic things like the reflector
175 layout
176
177 * Improved reading speed for corsika files
178
179 * Improved memory handling (if a large ampount of memory was needed
180 for a single event all further events were stored in the same
181 memory and it was never freed, so the program took this memory
182 until the end)
183
184 * Converted the code from MMCS' reflector program to MSimAtmosphere
185 (instead of the tables build in for MAGIC Winter and Summer
186 atmosphere we use the values written by Corsika fitted to the
187 tabulated atmosphere given as input)
188
189 * For caluclating the displayed image parameters in ceres a basic
190 image cleaning removing isolated pixels is now done.
191
192 * The magnetic field direction (ARRANG) is now taken into account
193
194 * Added plot for the energy threshold after trigger ''Threshold''
195
196 * Added plot for the effective collection area after trigger ''TrigArea''
197
198 ;star
199
200 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
201
202 * The definition of fConcCore has slightly changed. The numbers
203 might decrease a little bit (the effect should be rather small)
204
205 ;ganymed
206
207 * added pointing model 328198
208
209 ;sponde
210
211 * The SrcPos plot for your MCs was so far meaningless because it just
212 displayes the MSrcPosCam data from the input star-files. Unfortunately,
213 this containes was never written to the star-files yet.
214
215 * A new Tab 'OnTime' is available which is an effective on-time
216 fit as in star but for all data. This is mainly for manual cross-check
217 of the effective on-time
218
219 * In some circumstances it might be necessary to re-calculate the
220 eff. on-time from the fit in the new tab, e.g. when a zenith distance
221 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
222
223 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
224 it to its own output file (for convinience)
225
226
227
228== Version 2.2 (2009/01/30) ==
229
230 ;SUGGESTION
231
232 * This release doesn't contain a major change which is expected to
233 change your results. Nevertheless there are small changes to
234 the calibration which can effect at least the first few hundred
235 events in any (mainly MUX and even more SUM) sequence a little bit.
236 So it is recommended although not necessary to reset your sequences
237 in the database before further processing.
238
239 ;NEW
240
241 * A first implementation of a Monte Carlo simulation program
242 (ceres - Camera Electronics and REflector Simulation) has been
243 implemented. It can simulate a full telescope already including
244 a complete reflector simulation and a flexible trigger and readout
245 simulation. Currently, no perfect setup is implemented and
246 especially the output of the program (data structure) should
247 be considered alpha state. Also the user interface is not yet
248 ready.
249
250 ;general
251
252 * All command line options after -- are now interpreted as
253 arguments (usually everything which doesn't start with a minus)
254 rather than options (usually everything which starts with a
255 minus). This allows to use file names starting with a -
256
257 * In all resource files you can now initialize the random number
258 generator. For details see: MJob::InitRandomNumberGenerator
259
260 * added a new program called ''readcorsika''. It's purpose is (in analogy
261 to readraw and readdaq) to read a Corsika output file (for now
262 only cherenkov output is supported) and print its contents in a
263 human readable form. It can also write the contents of this file
264 into a root-file.
265
266 * The calculation of the maximum distance to the origin in a MGeomCam
267 has been improved (edges might be further away than the sides).
268 This is just a tiny change but it might change the appearance of
269 the radial profiles a little bit.
270
271 * The default binning of the center-of-gravity plot has slightly been
272 increased
273
274 ;Database
275
276 * Added informations about the DC currents (fMinCurrents, fMedCurrents
277 and fMaxCurrents). The values are retrieved from the plots showing
278 the average DC currents of all pixels versus time.
279
280 * Websites with tables have now the opportunity to remove lines
281 ('-' button at beginning of each line) and get all lines back
282 ('+' at top of the column)
283
284 * Websites: added option to query only sequences containing sumtrigger
285 events
286
287 * Websites: added option to group by date (year, month, night) for runs
288 and sequences and enabled that combining of different group-bys,
289 e.g. status, date and source is possible
290
291 ;automatic analyis
292
293 * Rewritten producing plots in the web.
294 New plots, namely the output of plotoptical.C (extinction curve from
295 KVA), plotstat.C (status of the automatic analysis (percentage of
296 processed, analysed data etc.)) and plotusage.C (statistics of the
297 condor usage in the data center) has been are available now next to the
298 plots of plotdb.C
299 Mean values from the plots (output of the macro) are provided in a
300 txt file now.
301 The creation of the plots for callisto, star and ganymed in the web is
302 now steered via database. Consequently the plots are faster and
303 reliable up-to-date.
304 For all plots, a new layout is available facilitating the browsing
305 through the plots and providing additional information on the
306 displayed values. (tabs.php) These plots are linked from the DB
307 websites and the wiki.
308
309 ;statusdisplay
310
311 * The ''Loop'' entry in the menu bar now contains an option to pause
312 the loop and to process single events.
313
314 ;merpp
315
316 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
317 instead of RunHeaders)
318
319 * Now allows to merpp files newer than 2008/09/03.
320
321 * Added fixes for wrong (wrong or double) run- and file-numbers
322 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
323
324 ;callisto
325
326 * Extracting the pulse position for the pulse position check events
327 with sum trigger were denied. This decreased the statistics
328 extremely and therefor the resulting puse position was calculated
329 quite weak. Now sum events pass the calculation if and only if they
330 have also a level 1 trigger.
331
332 * the extraction of pedestal events and pulse position from the
333 first data events is now more automatic and makes sure that
334 a more precise number of events is extracted independent of
335 the ratio with which pedestal events or events with signals
336 are contained in the data.
337
338 * Updated Muon calibration constants for all MUX data (teh changes were
339 all smaller than 5%)
340
341 ;star
342
343 * For the calculation of the effective on time all sum-triggered events
344 were skipped. Now all Level1-triggeres events will pass. This might
345 result in a slight inaccuracy of the effective on time.
346
347 ;ganymed
348
349 * If the source position is more than 1deg away from the camera
350 center an error is raised now.
351
352 * Hopefully fixed the bug ''ganymed crashes when resized''
353
354 ;sponde
355
356 * Fixed a problem which causes the fitted spectral slope to be displayed
357 incorrectly. If you use MJSpectrum::FormFlux in your macros make
358 sure that the parameter 0 of your fit is negative.
359
360 * Added a histogram showing the read source position of your MCs
361
362
363
364== Version 2.1.1 (2008/08/04) ==
365
366 ;Database
367
368 * Added the median number of photo electrons from the calibration
369 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
370 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
371
372 * Added fTotOnTime, which is the on-time as given by the run-headers
373 (in contradiction to fAbsOnTime which comes from CC)
374
375 * Added new primaries for the new data structure (Magic II): for the
376 tables dealing with sequences (SequenceBuild Status, Sequences,
377 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
378 this is the telescope number (fTelescopeNumber) for the tables dealing
379 with runs (RunData and RunProcessStatus) this is in addition the file
380 number (fFileNumber)
381
382 * Added column fPriority to the status tables to be able to steer the order
383 in which the data is processed. As default the run, sequence and dataset
384 number are used.
385
386 ;automatic analyis
387
388 * Adapted scripts to the new data structure: They can handle now different
389 telescopes (getting the information as usual from the database).
390 The paths for Magic 2 are not yet implemented.
391
392 ;general
393
394 * should work now with root 5.20/00 (please note that root 5.20/00
395 we encounter crahses in the status display which are ot yet
396 understood)
397
398 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
399 instead of the base name of the file. This makes them easier to
400 access from the code
401
402 * Default Monte Carlo names in MSequence do not require the _E at
403 the end anymore
404
405 * where abrrevating a sequence file with a sequence number is possible
406 also "telescope:sequence" is now accepted, e.g.:
407 star 2:2000123 --out=output
408 see the programs' help for more details.
409
410 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
411 from the database. See the constructors for more details.
412
413 * MReadTree now supports friends
414
415 * MReadTree can now read also files not written by MARS and store
416 the data encapsulated in emulated MParContainers
417
418 * added a new starguider calibration valid since 15.1.08
419
420 ;showplot
421
422 * showplot can now read more than one file at once. This is especially
423 inetersting if reading files containing pure canvases
424
425 ;merpp
426
427 * we merpp the dc currents now also from the camera reports (they have
428 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
429
430 * In the automatic analysis we omit merpping of the currents from the
431 caco files and use the lower rate camera reports from the cc files
432 instead
433
434 * merpp has been redisigned to allow merpping of the cc-reports
435 of a whole sequence. This allows to design a very simple analysis:
436 mkdir output
437 ./callisto 100776 --out=output
438 ./merpp 100776 output
439 ./star 100776 --ind=output --out=output
440 Instead of the sequence number also sequence files are accepted.
441
442 * Implemented a fix for run-numbers between 1001348 and 1001396
443 which were incorrectly assigned by the cc.
444
445
446 ;callisto
447
448 * added a filter again which was was removed in the last release.
449 it removed the most brightest events. This should not change
450 any analysis result because these events are so bright that
451 they cannot be analysed anyway, but the bad-pixel plots doesn't
452 show outliers.
453
454 * updated muon calibration constants for the periods 51-57,
455 58-63 and 67-
456
457 ;star
458
459 * The camera currents are now displayed with the rate of the camera
460 reports instead of the caco reports
461
462 ;ganymed
463
464 * if mc camera files are new enough (>=8) the source position in the
465 camera is now calculated from the stored telscope and shower
466 orientation (Note, that this might not be suitable in all cases
467 depending on the aim of the study. These case still needs
468 implementation)
469
470
471
472== Version 2.1 (2008/06/18) ==
473
474 ;Database
475
476 * introduced average temperature and wind speed from star-files
477
478 * introduced average values from Pyrometer (mainly Cloudiness)
479
480 * introduced the ratio of accepted calibration events in the
481 calibration run
482
483 * introduced the average rates of the different trigger pattern,
484 e.g. the rate of pedestal and calibration events, from the signal-file
485
486 ;general
487
488 * fixed GroupBy options in plot*.C macros
489
490 * only display KVA points (not the Tuorla points) in plotoptical.C
491
492 * all programs now allow to add resources to the ones from the resource
493 file or overwrite them from the command line. This can be done like this
494 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
495 if something seems to be wrong you can debug what the program is doing
496 using the option --debug-env=3
497
498 * increased the diversity of debug levels. That also means that with -v3
499 you get now less output, i.e. only the output which is important for
500 an analysis. To get more output which helps for debugging try 4, 5 and 6.
501
502 * fixed a problem in the task synchronizing the reading of the reports
503 and the data stream. The effect was that in some circumstances the last
504 events of some trees could have been skipped. Since this is only a
505 very tiny part of the data no severe effect to your analysis results
506 is expected (an exception might be very short, i.e. singel runs,
507 datasets).
508
509 * Dataset file now allow to include the sequence file directly within
510 the dataset file and also allow to exclude single runs from the dataset.
511 (for more details see Class reference of MDataSet)
512
513 * Sequence files now allow for excluding runs from the analysis
514 (for more details see Class reference of MSequence)
515
516 * added code to process the sum-trigger flag
517
518 * the histogram classes MH3 and MHn now support profile histograms
519
520 * the histogram classes MH3 and MHn now support labels at the axis
521
522 * the Random Forest Train-classes (MJTRain*) now store the used datasets
523 in the output file
524
525 * the MFMagicCuts have a new option to allow a linear area cut (for
526 special studies)
527
528 * The liniking of the shared object is now done into a file defined
529 by 'mktemp'. This should be a local file system which accelerates
530 liniking a lot.
531
532 * The code has been prepared for compilation with root 5.18/00d
533
534 * The MHEnergyEst histogram now shows the distribution of
535 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
536 and (Eest-Emc)/Emc vs Emc.
537
538 * fixed mars (event display) for merpped raw-data and MC data
539
540 * adapted the synatx of sequence files to allow for the new run/file
541 scheme. For more details see class description of MSequence
542
543 ;showplot
544
545 * Added support for tiff files
546
547 * Added support for csv files (tables containing tab number,
548 name and title)
549
550 * Tabs now can have a title which is displayed in the postscript file
551
552 * When multiple file are written at once (e.g. pngs from a display)
553 it is now possible to use the tab name and or tab number in the
554 file name. For details see showplos's help.
555
556 ;merpp
557
558 * Implemented cc file version 2008-02-20/0
559
560 * Implemented cc file version 2008-05-19/0
561
562 * With new options merpping can be restricted (in addition to the
563 run-number) also by telescope and file number.
564 For details see "merpp --help"
565
566 * Implemented raw data format 11 (the most important change, except
567 from plenty of changes in the format definition, is the addition
568 of the file-number in the header) If nobody makes a mistake this
569 format should have the advantage that it is by definition forward
570 compatible, so old programs will be able to read newer formats.
571
572 * Added Pyrometer information to default output (stored in a new Tree
573 Pyrometer, needs a complete new merpp, i.e. new calibration)
574
575 * Merpping (also update) can now be restricted to one single report.
576 For example:
577 If you want to update an old file with Pyrometer information call
578 merpp --only=Pyrometer --update
579
580 ;callisto
581
582 * in the pedestal processing now at least 50 processed events are
583 required for succeeding.
584
585 * the signal and calib files now contain also the sequence information
586
587 * the two MPedestalCam in the calib file now have proper names
588 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
589
590 * Both pedestal cams now contain the number of events processed
591
592 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
593 i.e. for the extraction of the calibration pulses basically the average
594 over all events of the first slice instead of all slices was used.
595 Since pedestal and calibration constants are continously recalculated
596 this only effected the very first events of every sequence.
597
598 * For the extraction of the position of the maximum sample now the
599 extraction range is set automatically to the extraction window,
600 before the whole accessible range was used.
601
602 * If the number of samples in the events and the number of samples
603 in the run-header disagrees now an error is raised (this can
604 happen in not well simulated Monte Carlo files)
605
606 * In the case of MUX-data pedestal events with the lvl1 trigger flag
607 could survive into the pedestal calculation -- fixed.
608
609 * Tab "TrigPat" added showing the distribution of the trigger pattern
610 as found in the run-files (normalized with the run length)
611
612 * The selection of events from the trigger pattern has been improved.
613 If the trigger pattern is corrupted events won't pass anymore.
614
615 * Added a new command line option --dev-null to suppress output of
616 Y-files (this is useful for test cases)
617
618 * added a new tab "CalPos" showing the arrival time of extracted
619 interleaved calibration events
620
621 ;star
622
623 * the star file now contains also the sequence information
624
625 * Added a new command line option --dev-null to suppress output of
626 I-files (this is useful for test cases)
627
628 * Tab "Rate" added showing the distribution of the trigger pattern
629 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
630 the Y-files (normalized with the run length)
631
632 * The effective on-time calculation doesn't use events with only
633 sum-trigger anymore
634
635 * The data in the MHWeather tab has been reorganized. The never
636 working solar radiation has been removed and the data from
637 the pyrometer (cloudiness, air and sky temperature) is
638 displayed in addition.
639
640 ;ganymed/sponde
641
642 * Now data points are even shown correctly if they have error bars larger
643 than one sigma. Points with null or negative significances are omitted.
644
645 * DrawNicePlot now allows to set a projection range
646
647 * Updates pointing models. One is applied after the implementation
648 of the new LUTS in August, the other one is applied after the
649 next major change of the pointing model in October. Note that
650 these models are preliminary and give wrong results below Zd=65deg
651
652 ;sponde
653
654 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
655
656 * a new option "--force-runtime" is available. In case of very short
657 datasets (for light-curves) which are in the order of a few
658 minutes the calculated effective on-time is not very acurate because
659 it is quantizised in the order of a minute. Therefore you can switch
660 to using the real run-time instead (remakrt: this ignores any
661 dead-time!)
662
663 * a more analytical way is used to "fill" Monte Carlos into regions
664 of impact parameters which have not been simulated because the
665 trigger efficiency is assumed to be 0.
666
667 * estimated sensitivity curves for hi and lo zenith angles are shown
668 scaled to the correct observation time and collection area
669
670 * the Monte Carlo events after cuts are now written to the output file
671 if an output file given
672
673
674
675 *** Version 2.0 (2007/09/03)
676
677 - database: the position used for the pulse pos check was missing
678 in the callisto output and could thus not be filled into the DB.
679 Also the old values seemed not exactly the PulsePos used for
680 teh check.
681
682 - general: Resource file now allow an Include-Resource, i.e. you can
683 read a resource file with default settings, include it in your
684 resource file and overwrite the settings in your file. More than
685 one include file is allowed. Inclusions can be iterative.
686 Include: mydefaults.rc yourdefaults.rc
687 The resources in the first file have higher priority than the
688 second file.
689
690 - general: Now the output files (calib*.root, etc) also contain the
691 resource file (to check it open it in the TBrowser and choose Print()
692 from the context menu)
693
694 - general: Dataset files now allow to overwrite the default path
695 to search for sequence and data files. Note, that the program
696 option and individual resources will overwrite it. For example:
697 SequencePath: /magic/montecarlo/sequences
698 DataPath: /magic/montecarlo/star
699
700 - general: Fixed a problem with variables in MDataPhrase. It seems
701 that only optimdisp (didn't work) was effected.
702
703 - general: Some improvements to the optim and train processing. For
704 example the ststud window now got a proper title.
705
706 - general: The "Status Display: " was removed from the window title
707 within an Eventloop.
708
709 - general: added a new flexible histogram-class (MHn) which can be used
710 for example in testing after optimizations or training to produce
711 user defined histograms.
712
713 - general: The Random Forest now allows attaching an evaluation
714 function which is applied to its output. This allows to train
715 on whatever you like (eg. train on log10(energy), but return
716 energy)
717
718 - general: The Random Forest training of energy (trainenergy.c) and
719 disp (traindisp.C) has been improved by more graphical output to
720 judge the result.
721
722 - general: The training of energy (trainenergy.C) has been improved
723 a lot by training on a different quantity than energy. It gives
724 a result which is highly independant of the source spectrum
725 and shows lower bias than all other options.
726
727 - general: Dataset files are allowed to contain collections of
728 datasets. For more details see the class reference of MDataSet.
729
730 - general: The default WobbleMode in a datset file now (if not
731 overwritten) is "auto", i.e. wobble mode is set if the dataset
732 doesn't contain off-sequences.
733
734 - merpp: Merpp can read file format version 9 now. Please realize
735 that for file format version 9 the extraction range is different
736 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
737 the first and last 15 slices have been removed from all MUX data.
738
739 - mars: Similar to writing movies you can now select events which
740 should be displayed in your display. Therefore add the following
741 lines to your mars.rc:
742 MFEvtNumber.FileName: ganymed00223552.root
743 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
744 The input file can be a ganymed-file after (ganymed*.root) or
745 before (ganymed*-summary.root) file. For example to select all events
746 from your on sample after cuts (excluding the ThetaSq cut) use
747 MFEvtNumber.Selector: DataType.fVal>0.5
748 To show all events from your on-sample after quality cuts
749 use the summary file instead.
750
751 - mars: new ways to call mars are implemented. Instead
752 of calling
753 mars filename.root
754 you can now also use
755 mars sequence.txt
756 or
757 mars sequence.txt inputpath
758 or replace sequence.txt by the sequence number if the default
759 sequence file should be used.
760
761 - mars: The default size has been increased
762
763 - mars: There are two new heckboxes which allow to switch off
764 the calculated image parameters
765
766 - callisto: was broken for MCs... fixed.
767
768 - callisto: improved calculation of spline coefficients a lot. This
769 leads to a further improvement of the event rate calibrating MUX
770 data of about 15% (175evt/s instead of 150evt/s)
771
772 - callisto: finally the raw data we read is now real 16bit (with
773 10bit precision) for MUX data and not a stripped 8bit number
774 anymore. Due to scaling of the numbers (without precision loss
775 into an [0-256[ range, the final numbers for pedestal, pedestalrms
776 and extacted signal don't change. However, at all places where
777 raw data is directly accessed (eg. saturation and variation
778 limits in the signal- and pedestal-extraction) the numbers
779 refer still to the data's 16bit range.
780
781 - callisto: The maximum arrival time difference used in the bad
782 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
783 for both, old FADC and MUX-FADC, data.
784
785 - callisto: Be aware that callisto is now calibrating the arrival time
786 in nanoseconds rather than time slices. Also all following tasks
787 have been changed to assume ns units now. If you star data
788 calibrated with an older version it might be necessary to adapt
789 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
790 to obtain optimal results. The plot in the PulsePos tab
791 will now be in ns, too. This might also mean that the Muon
792 analysis in star might not work as perfect as expected as long
793 as old files read in.
794
795 - callisto: The calibration constants of earlier updates got lost
796 somehow. All constants have been updated.
797
798 - star: The PSF is now determined from the profile of the ArcWidth
799 instead of arcwidth/radius. The old way gave to much weight
800 to the bins with low statistics. The reference lines have been
801 updated.
802
803 - star: For speed reasons events suitable for the muon analysis
804 are now also preselected by fConcCOG<0.1 which seems to be a very
805 good preselector for muons.
806
807 - star: is now calculating a new timing parameter the Slope along
808 the major and minor axis of the shower. Therefore a numerical
809 solution of a line-fit is used. To use MHillasExt.fSlopeLong
810 and MHillasExt.fSlopeTrans don't forget to multiply it with
811 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
812
813 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
814 have been removed from MNewImagePar. They have never been good for
815 anything.
816
817 - star: Implemented a new recursive algorithm which is supposed to be
818 faster. Also implemented new cleaning oiptions, which are:
819 + CleanLevel0:
820 The cleaning level above single core pixels can be kept
821 + KeepIsolatedPixels:
822 Define whether single core pixels should be kept
823 + TimeLevel1:
824 The coincidence window in nanoseconds to single used neighbors
825 + TimeLevel2:
826 The coincidence window in nanoseconds to two used neighbors
827 + PostCleanType:
828 MOde in which a time dependent post cleaning should be applied
829 0: No post cleaning
830 1: Require for each used pixels at least one used neighbor
831 within a time-window of CleanLevel1
832 2: Require for each used pixels at least two used neighbor
833 within a time-window of CleanLevel2
834 3: Require first two and second one used neighbor
835 within a time-window of CleanLevel1 and fCleanLevel2
836 respectively
837 + RecoverIsolatedPixels:
838 - recoveres isolated core pixels if they have a used neighbor
839
840 - mars/star: The new default cleaning is:
841 + CleanLevel1: 6.0
842 + CleanLevel2: 3.0
843 + CleanTime1: 1.75
844 + CleanTime2: 1.75
845 + PostCleanType: 3
846
847 - star/ganymed: The old spark-cuts have been replaced by new ones.
848 These new spark cuts have been cross checked with the sequences
849 84720 (before splitter), 101041 (after splitter) and 223539 (new
850 FADCs). In all cases they seperate pretty well, but of course not
851 perfect. Monte Carlos have suggested to tighten the cuts a little
852 bit further at low sizes. This has been done.
853
854 - ganymed: IMPORTANT - The spark cuts have been changed to match
855 all available data more or less well. This might mean that for
856 YOUR data there are still sparks visible.
857 Whenever you do an analysis you have to make sure that NO sparks
858 survive your cuts!
859
860 - ganymed: The old hadronness and size cuts have gotten new indices
861 (10, 11). The old indices 8 and 9 now mean an additional condition
862 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
863 If you want to switch off this cut just move the line far away enough,
864 e.g. by setting c[9] to -500. Please update your ganymed.rc files
865 accordingly!
866 The unit of c[9] is deg. It is the dist at which your cut will
867 cross the slope==0. The unit of the slope is ns/deg. So if
868 you readin files calibrated with an older Mars-version you
869 have to adapt the default value for c[9] to the FADCs:
870 - Multiply by two for the MUX FADCs (run number > 200.000)
871 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
872 - Multiply by 42 for the meaning of life (run number = 200.000)
873
874 - ganymed: The old Cut0 is now called CutQ and is calculated before
875 the source position is caluclated. If you need a quality cut
876 including source dependant data (be very carefull with this!)
877 you have to use Cut0 instead.
878
879 - ganymed: now properly supports three off regions in wobble mode.
880 It will be the default from now on in ganymed_wobble.rc. To change
881 the number of off-regions use
882 NumOffSourcePositions: 1
883 in your ganymed.rc. Also by default no off-theta cut will be done
884 anymore so that you will get a background level higher than the
885 signal level in your ThetaSq plot for ThetaSq>0.2.
886 Due to this be carefull changing the scaling mode away from
887 "None". You will underestimate your signal if your scale interval
888 is not properly set.
889 (Rem: ThetaSqN is no longer needed)
890
891 - ganymed: is now storing the events of all (on- and off-)
892 source positions even in the case of more than one off-source
893 position. This should allow sponde to work properly and the
894 energy estimation is done correctly in all cases (without any
895 "nearest position" trick)
896
897 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
898 with a real pointing model for the starguider is done, calibrated
899 with more than thousand tpoints taken from this date on.
900
901 - ganymed: was broken for Wobble-MCs... fixed.
902
903 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
904 has changed. Note that your old ganymed.rc will be incompatible
905 with the new algorithms! Please check the ganymed.rc files and
906 the class description of MFMagicCuts for more information.
907 It is recommended at the moment to use identical Disp-Parametrizations
908 for on/off- and wobble-mode. If cuts are optimized only
909 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
910 should be optimized. All other values should be kept as they are.
911 If you want to do an anylsis without timing a parameters, you can
912 switch off the timing cuts by seeting parameter 7 to a very small
913 value (eg. -99). To remove the slope parameter from the disp
914 paremtrization set parameter 8 to 0.
915
916 - ganymed: The distribution of observation time versus zenith
917 angle is now shown for off- AND on-data.
918
919 - ganymed: The contents of the source position plot are no longer
920 averaged, thus a lot of (fake) events between the two wobble
921 positions have disappeared.
922
923 - ganymed: There is a new tab "CutT" it contains the VsSize plots
924 with the CutT, whihc is defined in ganymed.rc, applied. It
925 is resonable to use your theta-cut for it, to see if there is
926 something strange (sparks!) in your signal-region.
927
928 - ganymed: To choose a dataset from a collection in a dataset file
929 use the new command line option "--dataset=12345"
930
931 - optim, sponde: should now properly support three off-regions.
932 Just produce your ganymed summary files with three off-regions.
933 optim and sponde will automatically get all off events from
934 all off-regions from this file. Please do not forget to
935 set the scaling in optimwobble.C properly:
936 fit.SetScaleUser(1./3);
937 it is not yet read in automatically (will follow soon).
938 In the case of fixed Scale you can also use
939 cuts.SetThetaCut(MFMagicCuts::kOn);
940 no off-cut needed.
941 Be carefull in case of three off-regions when switching on
942 scale mode. Make sure that the scale interval is set correctly.
943
944 - sponde: sponde.rc and sponde_onoff.rc are now idetical
945
946 - sponde: the resouce files have been rewritten with a lot of
947 comments and a well working parametrization for an energy estimator
948
949 - sponde: In the estimated energy versus monte carlo energy plot the
950 contents where exchanged.... fixed.
951
952 - sponde: the so called "accurate"-mode has been removed. It didn't
953 give any improvement in accuracy, only decreased execution speed.
954
955 - sponde: the so called "simple"-mode has been removed. It didn't
956 give any improvement in simple.
957
958 - sponde: the so called "refill"-mode has been removed. It was anyhow
959 not implemented.
960
961 - sponde: now checks whether the theta distribution of your on-data
962 and the theta-distribution of your Monte Carlo sample (after
963 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
964 sample is incomplete) execution is stopped. Execution can be forced
965 using the new option --force-theta. Use this option with care!
966
967 - sponde: Proper collection areas can now be constructed also from
968 Monte Carlo samples generated with different maximum impact
969 parameters. Note that in previous version you neither got
970 a warning or failure, nor was there any obvious sign that the
971 collection area was overestimated due to usage of files with
972 different maximum impact parameters.
973
974 - sponde: If MC files with different lower energy limits are used
975 the primary MC spectrum is artificially completed down to the
976 lowest energy used at all. WARNING: that this gives correct
977 collection areas ONLY if none of the events in this region would
978 survive your cuts at all.
979
980 - sponde: the output file now contains more information about
981 the spectrum (eg. the full 2D collection area histogram).
982 Note, that this information can only be written to the file
983 if it is stored automatically via command line argument.
984 If you only store the status display from within the display
985 the information is lost.
986
987 - sponde: added a new tab "Disp". It shows the residual of the disp
988 (Disp-Dist) versus several parameters and it is meant to judge the
989 quality of the disp estimator. In the ideal case the residual is zero
990 and doesn't depend on any variable. The tab is displayed after
991 CutQ and Cut0.
992
993 - sponde: added a new tab "Energy". It shows the residual of the
994 energy (lg(estimated energy)-lg(monte carlo energy)) versus
995 several parameters and it is meant to judge the quality of the
996 energy estimator. In the ideal case the residual is zero
997 and doesn't depend on any variable. In reality even a good estimator
998 can show residuals versus Monte Carlo energy. The tab is displayed
999 after all cuts.
1000
1001 - sponde: added a new tab "EventDist" showing the unweighted real
1002 absolute number of events of your sample after cuts. This tells
1003 you how many events with this energy you had in your MC files.
1004 The same information you get from the error bars of the weighted
1005 histograms, but this is less intuitive.
1006
1007 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1008 for comparison. It is not meant to show these curves in
1009 publications, they are only for production.
1010
1011 - sponde: The OriginalMC tree with the events produced by corsika
1012 is now processed only once
1013
1014 - sponde: Finally fixed most annoying bug, which has effected the
1015 last bin of the collection area. It was the problem that binnings
1016 of root histograms are from 1 to n (included) but there was a C-like
1017 loop in sponde from 0 to n (excluded). Now the loop also includes
1018 correctly under- and overflow-bins. The worse thing with this is,
1019 that for the events in the highest bin not only the bin-content
1020 was wrong, but also the weights applied to these events, which could
1021 in pricipal effect also other parts of the distribution (eg. due
1022 to energy estimation). Fortunately it effected only a few events
1023 in most cases.
1024
1025
1026
1027 *** Version 1.2 (2007/05/14)
1028
1029 - database: The database now has two new values Unsuitable50 and
1030 Unsuitable01. They express the number of pixels which are
1031 unsuitable for more than 50%, respectively more than 1%, of
1032 all calibrated event. It is a more accurate number than the
1033 previously used numbers, because they only take the first
1034 calibration (ignoring the interleaved calibrations) into account.
1035
1036 - database: The database now has two other new values UnsuitableMax and
1037 DeadMax. They express the maximum number of pixels which were
1038 unsuitable, respectively dead, during the sequence. Because
1039 of high pedestal rms (cars passing) a few events with very high
1040 numbers of unsuitable pixels can happen. Not to suffer from this
1041 effect we don't take the highest 0.1% of the numbers into account.
1042
1043 - general: fixed a bug which caused callisto and star to stop working
1044 properly because the callisto output was currupted
1045
1046 - general: a script called scripts/makemovie has been added which
1047 simplified the process of producing several movies from a single
1048 sequence with different setup.
1049
1050 - callisto: Some more code cleanup. Started to remove old obsolete
1051 code from cvs.
1052
1053 - callisto: The extraction of the pedestal with the extractor was
1054 not random. It seems that extracting at one position is still biased
1055 (for example in the first or last slices we could still suffer from
1056 switching noise) Now it is completely random.
1057
1058 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1059 pedestal files) individual pixels could be skipped due to high
1060 variations. This was already the case for the pedestal extraction
1061 from the lo-gains since the beginning and properly handled
1062 there, but was introduced in the extraction from the pedestal files
1063 a while ago. To calculate the average value it was still divided
1064 by the number of events procesed not by the number of summands
1065 really summed. This let to a pedestal which was a tiny amount too
1066 small (for a few piels in the order of 0.1%). This led to an slightly
1067 positive offset of the randomly extracted pedestal for a few pixels.
1068 I doubt that this has a big effect on the result, because the effect
1069 on the individual numbers is quite small. Due to this it is suggested
1070 that you rerun your calibration to make sure you are without any
1071 avoidable bias.
1072
1073 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1074 the median rms of the absolute arrival time and expressed in significance
1075 levels. This replaces the old meaning of an abolute upper limit. An
1076 absolute upper limit doesn't make much sense, because in our data
1077 all arrival times are shifted at the same time (in fact it might be
1078 a shift of the artificial trigger w.r.t. to the light flash).
1079
1080 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1081 of the number of unsuitable pixels over the whole sequence. This
1082 is usefull mainly to judge if an intermediate calibration had
1083 problems.
1084
1085 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1086 of the number of dead pixels over the whole sequence. Dead pixels
1087 in this context are unmapped pixels, i.e. pixels which could not
1088 be interpolated, and thus are ignored in the further analysis.
1089
1090 - callisto: It is now possible to use the position of the maximum
1091 of the spline as arrival time instead of the leading edge even
1092 when using the integral for the signal. Therefor set the extraction
1093 type to kIntegralRel ("IntegralRelative") and the relative height
1094 ("HeightTm") to -1:
1095 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1096 MJPedestalC1.ExtractSignal.HeightTm: -1
1097
1098
1099
1100
1101 *** Version 1.1 (2007/04/27)
1102
1103 - general: The new class MGeomCamDwarf contains the camera geometry
1104 for our prefered Dwarf camera and can be used to create general
1105 geometries of roundish or hexagonal cameras.
1106
1107 - mars: The default cleaning is now abolute 8.5/4.0.
1108
1109 - mars: The resource file mars.rc now contains examples for MUX data
1110
1111 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1112 data containing only 10-bit information is still cooked down to
1113 8-bit, by cutting away the lowest 8-bit.
1114
1115 - merpp: When reading raw data the data is now stored in a single
1116 array. The lo-gain array is obsolete. The interface stays the same.
1117
1118 - callisto: To process the new MUX data use the resource file
1119 callisto_mux.rc
1120
1121 - callisto: The -root and -raw options to read merpped raw data have
1122 been removed
1123
1124 - callisto: If the -mc option is given the sequence-name can now be
1125 replaced by the MC sequence number
1126
1127 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1128 -mc option can now be omitted
1129
1130 - callisto: Started further simplification by removing obsolete
1131 dependancies on MCalibIntensity*Cams.
1132
1133 - callisto: removed unsused intensity calibration from MJCalibration
1134 for further simplification
1135
1136 - callisto: for simplification removed references to
1137 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1138 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1139 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1140 (this should at minimum change nothing at all, and at maximum
1141 improve thing if these containers where somewhere not handled
1142 properly)
1143
1144 - callisto: Added the option to write an event movie. Please use
1145 this option with care (huge files) but exessively to understand
1146 our events. For further documentation please refer to the
1147 IACT wiki
1148 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1149
1150 - callisto: Improved binning for the pulse position check histogram
1151
1152 - callisto: The code calculating the pulse position checknow takes
1153 the pedestal into account
1154
1155 - callisto: The arrival time is now stored with full precision this
1156 helps to get rid of artefacts in histograms. For the signal this
1157 is not necessray because it is displayed in log-scale anyhow
1158
1159 - callisto: Fixed a problem with internal exclusions. Pixels which
1160 have once been marked as unsuitable didn't get the necessary
1161 histograms filled anymore to be rechecked with each interleaved
1162 calibration.
1163
1164 - callisto: The relative arrival time resolution (the rms of the
1165 relative arrival time offset) is now checked against its
1166 median and the median deviation, instead of the average
1167 plus an absolute offset.
1168
1169 - callisto: The relative arrival time offset is now calculated
1170 w.r.t. its median not w.r.t. to an artificial reference pixel.
1171
1172 - callisto: The relative time calibration now marks pixels with
1173 outlaying offset as unsuitable
1174
1175 - callisto: The interleaved relative time calibration has been switched
1176 on. The advantage is that pixels which are marked as outliers
1177 now can recover. An improvement over time is not expected, because
1178 the relative time calibration seems stable.
1179
1180 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1181 option can now be omitted.
1182
1183 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1184 or the option "-mc" is specified as default the monte carlo datacenter
1185 paths (/magic/montecarlo/...) are used if not overwritten in the
1186 dataset file.
1187
1188 - ganymed: The output files now contain run- and event-number for all
1189 events, accessible as RunNumber.fVal and EvtNumber.fVal
1190
1191 - ganymed: Added a plot showing the source position in the camera also
1192 for wobble mode
1193
1194 - ganymed: In addition to the existing task which can be setup to
1195 be executed after Cut1 a final task called "EstimateEnergy"
1196 has been added, executed before writing the final output
1197 (ganymed00000000.root). The task setup in all three cases
1198 can be choosen individually. (For all three(!) cases you
1199 can for example choose MRanForestCalc. For examples see all
1200 sponde*.rc and all ganymed*rc)
1201
1202 - ganymed: If a container "MEstimatedEnergy" is found in the
1203 parameter list (eg. because it was setup by MEstimateEnergy)
1204 it will be written to the output file.
1205
1206
1207
1208 *** Version 1.0 (2007/02/16)
1209
1210 - database: Website to plot values from the database has been added.
1211
1212 - database: The rate of spark events as found by star is now kept
1213 and the rate after cleaning is now with spark events subtracted
1214
1215 - general: The changes to the interpretation of phrases lead to
1216 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1217
1218 - general: Added example files how you can create your own calendar
1219 (eg. as christmas present) with Mars. Just run
1220 root macros/tutorials/calendar.C
1221
1222 - general: Added a possibility to display grouped data in the plotdb.C
1223 macro (and similar macros). This allows to plot hourly, nightly,
1224 weekly, monthly and yearly averages.
1225 For more details see the plotall function of the macro
1226
1227 - general: fixed the error display of the camera display. It showed
1228 wrong results.
1229
1230 - general: fixed a memory leak when reading many MStatusDisplays
1231
1232 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1233 between a spherical and a parabolic mirror
1234
1235 - callisto: We have a new pulse position check which takes the properties
1236 of the extractor automatically into account. So no need to set
1237 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1238 left is done. If possible the lo-gain extraction start and hi-gain
1239 extraction end is changed accordingly. If no proper extraction range
1240 can be set (hi-gain too much to the left) an error is raised.
1241
1242 - callisto: New swapped pixels have been found and corrected
1243
1244 - callisto: Redone the signal extraction this includes:
1245 + Unified the algorithms to extract the pedestal for all pedestal
1246 extractions done
1247 + Unification of hi- and lo-gain into one array
1248 + Unification of hi- and lo-gain extraction for Spline and
1249 Digital Filter (means now exactly the same algorithm is used,
1250 not a copy-and-pasted one)
1251 + Store pedestal subtracted data in a common place
1252 + Improved extraction algorithms. If the algorithms search a
1253 maximum but don't find one they don't return the maximum anymore
1254 + Improved the extraction such that a information for signal
1255 and time which is consistent is returned
1256 + replaced the numerical spline with a (not slower) analytical
1257 solution
1258 + Lowered the saturation limit from 250 to 245 to make sure that
1259 we are far away in all pixels from problems with the clock-noise
1260 + The start of the lo-gain extraction is calculated from the hi-gain
1261 arrival time. In case of saturation an estimation is used.
1262 + the hi-gain window was extended to slice 16. This allows extraction
1263 of very late pulses in single pixels or of huge hadron showers.
1264 + Now uses the lo-gain extraction range for pedestal extraction,
1265 not the hi-gain range in the lo-gain
1266
1267 - callisto: New hi-/lo-gain calibration constants have been produced
1268 for all periods from the statistic of the whole period. They are
1269 now used automatically depending on the periods. The old constants
1270 where deviation in avarega about 2%-3%. The constants are very
1271 stable from period to period (<<1%) except for exchanged channels.
1272 In a few cases the constants used so far were off by 1%-2% (maybe
1273 temperature effects?)
1274
1275 - callisto: To gain obsolete space we do not write the
1276 MPedestalFundamental anymore. Also calibration and bad pixel
1277 treatment is not done for it anymore because it has never been used.
1278
1279 - callisto: Fixed a bug in the seuqence handling which caused the
1280 light condition to be ignored
1281
1282 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1283 basically the same as "Cleaned" but the distribution devided into
1284 the events fullfilling a spark cut or being rejected by it.
1285 This cut can be changed from star.rc (see example inside) by
1286 the "SparkCut" directive
1287
1288 - star: Star displays now the average individual pixel-rate (IPR) versus
1289 time and the average discriminator threshold (DT) of all pixels.
1290
1291 - optim: fixed a problem with the optim-macros which was due to a bug
1292 in the new phrase parsing
1293
1294 - ganymed: To get a nice FalseSource plot (instead of the all-information
1295 debug plot displayed as a standard plot) use the context menu
1296 somewhere between the two upper plots, click on "DrawNicePlot"
1297 and enjoy the result. (It is the same context menu which contains
1298 the other options)
1299 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1300
1301 - ganymed/optim/train: The cut program, trainings- and optimization
1302 macros could run with less files found than expected from the
1303 sequence-files. No the execution is stopped in this case.
1304
1305 - ganymed: now stores the dataset in the output file with all information
1306 contained (as sequence number, sequence path, data path) so that the
1307 used dataset file can be recreated complete from the output
1308
1309 - sponde: now also allows the uasge of random forest
1310
1311 - sponde: added a plot showing the cut efficiency
1312
1313 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1314 errors (eg. effecting the collection area) because the errors of the
1315 two histograms were swapped in the calculation, which makes a difference
1316 in the case the histograms contains weighted events. Aditionally the
1317 totalarea was incorrectly taken into account, which results in too small
1318 errors, which makes a difference at low statistics were the errors
1319 or the collection area dominate.
1320
1321
1322
1323 *** Version 0.10.3 (2006/10/23)
1324
1325 - database: Implemented ObservationMode flag in websites.
1326
1327 - database: For sequences there is now also the stoptime available on the
1328 websites.
1329
1330 - database: Removed ManuallyChanged flag from sequence-info websites,
1331 as it is not needed anymore with the new sequence building algorithm.
1332
1333 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1334 Class for calculation of confidence intervals (upper limits).
1335 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1336 Please read the class instruction of TRolke for more information.
1337
1338 - general: The programs now return 0xfe if the requested resource file
1339 doesn't exist.
1340
1341 - general: Errors comming from root itself are now not output to
1342 stderr anymore but to our default (colored) log-stream.
1343
1344 - general: Changed the interface to TFormula such that now everything
1345 is parsed by TFormula, which should allow to use phrases even
1346 without paranthesis correctly parsed.
1347
1348 - callisto: replaced the AdHoc number of effective integration slices
1349 in the digital filter by an average of the correct number, averaged
1350 over all possible set of weights. This also gives correct numbers
1351 for the lo-gains which were totally wrong before.
1352
1353 - callisto: drastically reduced memory consumption by not storing
1354 all intermediate calibration results in memory anymore (we might
1355 write them into a file in the future)
1356
1357 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1358 debug plot displayed as a standard plot) use the context menu
1359 somewhere between the two upper plots, click on "DrawNicePlot"
1360 and enjoy the result. (It is the same context menu which contains
1361 the "DrawAll" option)
1362 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1363
1364
1365
1366 *** Version 0.10.2 (2006/10/15)
1367
1368 - general: changed the building of the sequence files such, that
1369 the source-/project name in case of wobble-sources is not the
1370 source/project of the first data run anymore but the new generalized
1371 wobble source/project
1372
1373 - general: Added some functions to MAstro to calculate sun and
1374 moon properties
1375
1376 - general: Added two new macros (starvisday.C and starvisyear.C)
1377 which allow to plot the visibility of several stars in one day
1378 or of one star along one year
1379
1380
1381
1382 *** Version 0.10.1 (2006/10/11)
1383
1384 - general: HTML logging output was distorted... fixed.
1385
1386 - general: Changed the writing of the sequencefiles such that only
1387 as many pedestal files as giving at least 1000 pedestal events which
1388 are nearby the first calibration run are used as pedestal runs
1389
1390 - sponde: In the calculation of the collection area(s) and the
1391 distribution for MOnte Carlo and estimated energy the error
1392 calculation was wrong because root didn't take the errors
1393 properly into account... fixed.
1394
1395
1396
1397 *** Version 0.10 (2006/10/10)
1398
1399 - general: all executables now check consistency of the root version
1400 installed with the root version used for compilation. The return
1401 code in this case is 255.
1402
1403 - general: The algorithm to build seqeunces has been redesigned
1404 completly. It is now more flexible in terms of a resource file
1405 resources/sequences.rc which can be used to partly overwrite
1406 the default algorithm and defined the important part of the
1407 algorithm. It also takes correctly into account several ways
1408 of taking wobble-data. Currently the new algorithm doesn't take
1409 the number of pedestal events anymore into account (so a sequence
1410 could have much less than 1000 pedestal events and data runs are
1411 no-more used instead)
1412
1413 - general: a lot of small changes to make the code compatible with
1414 root 5.12/00 and gcc 4.1
1415
1416 - general: Fixed some warnings thrown if more warnings are switched
1417 on in the compiler
1418
1419 - general: Added a function to MMath which returns the Median of
1420 the distribution abs(y[i]-median) but at 68:32 division instead
1421 of 50:50, which is somehow the median counterpart of the rms.
1422
1423 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1424 even if they are compressed with gzip (recommended compression
1425 is with "-1")
1426
1427 - showplot:
1428 + batch mode creation of image files now works with root 5.12/00
1429 + added support for writing bmp (though it never produces
1430 bmp which can be read by programs like xv or gimp)
1431 + added support for xml
1432 + added new option to start the display with a different size, by
1433 --display-width=nnn or --display-height=nnn
1434 + added options to define the canvas size when the display is started
1435 --canvas-width=nnn or --canvas-height=nnn
1436 the option can also be used for batch-mode conversion
1437 + added an option which automatically fits the display size to the
1438 desktop-size: --auto-size
1439
1440 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1441
1442 - merpp: allow the reports to have 1000ms due to a bug in the camera
1443 program.
1444
1445 - callisto: New swapped pixels have been found and corrected. For
1446 details see MRawRunHeader::FixAssignment()
1447
1448 - callisto: Callisto now raises an error if one of the input files could
1449 not be opened.
1450
1451 - callisto: In some rare cases it could happen that in the signal
1452 extraction of the digital filter the extractor returned nonsense
1453 results due a wrong initializion of a variable (this happens in
1454 cases in which the extracted signal is exactly zero or the
1455 digital filter couldn't slide because of a too small extraction
1456 window, which could happen in the lo-gain extraction)
1457
1458 - callisto: The lo-gains have been marked as valid in some cases
1459 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1460 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1461 smaller than the number of slices (fLoGainWindowSize) needed
1462 by the lo-gain extractor
1463
1464 - callisto: Updated absolute calibration constants (muon calibration)
1465
1466 - callisto: fixed a bug which caused the hi-gain saturation not
1467 to be handled properly in the spline (the position of the
1468 saturation was calculated incorrectly)
1469
1470 - callisto: fixed a bug which gave weird results if hi- _and_
1471 lo-gain could not be extracted properly. In some cases hi-
1472 and lo-gain have not been extracted at all and the random result
1473 got calibrated. In other cases the hi-gain was saturating and the
1474 lo-gain has not been extracted. For this a completly arbitraty
1475 scale factor was applied to the result from extracting the
1476 charge of the saturating hi-gain.
1477
1478 - callisto: improves handling of extracted signal if lo- and/or
1479 hi-gain could not be extracted properly. If no appropriate
1480 calibration of either the signal or the arrival time is possible
1481 the pixel is now markes as unsuitable instead of estimated.
1482
1483 - callisto: Fixed a problem in the spline extraction which gave
1484 weird results if the signal was extracted from the first (and
1485 highest) slice (as a workaround extraction from the first
1486 slice has been forbidden)
1487
1488 - callisto: Fixed a bug regarding the use of the QE which doesn't
1489 effect the result because the default is used anyhow.
1490 (The bug was there since 14/07/2005)
1491
1492 - callisto: Changed the default for fgLoGainStartShift to -2.4
1493
1494 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1495 factors to be always 10 for all pixels as soon as the first
1496 calibration update has happend.
1497
1498 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1499 was off by more than one slice (which gives wrong values for
1500 pixels which have saturated the hi-gain) This was a problem
1501 mainly for timing studies, not so much for the automatic standard
1502 analysis. Also the values for the Spline have been changed slightly:
1503 + Digital Filter from 1.70 to 0.95
1504 + Spline from 1.39 to 1.30
1505 The numbers were sorted out by an extensive test in the
1506 test-database.
1507
1508 - callisto: Removed the tab showing the average calibrated arrival
1509 time. It never gave useful information.
1510
1511 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1512 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1513 and both were extracted because the hi-gain was above the
1514 LoGainSwitch.
1515
1516 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1517 lo-gain pulse position (after application of LoGainOffset, which
1518 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1519 have saturated and both were extracted because the hi-gain was above
1520 the LoGainSwitch.
1521
1522 - callisto: After extensive tests a new threshold level for determination
1523 of the pulse position has been found at 50phe. This is due to the
1524 fact that for lower pulses the arrival time changes its average
1525 behaviour dramatically. It tends to the average of the extraction
1526 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1527
1528 - callisto: Added two more plots to the calibration part. The average
1529 extracted signal and the average extracted arrival time as
1530 extracted by the signal extractor (This can help debugging problems
1531 because it doesn't involve a fit)
1532
1533 - star: changed the fit for the effective on time such that initial
1534 values are calculated automatically now instead of using build
1535 in values. This makes the fit more indepedant of the underlaying
1536 rates. With a test of ~350 sequences in the test database it could
1537 be shown that the new fit gives the same result +/-1sek.
1538 The highest deviation was +5s the lowest -10s. You can now control
1539 the bahaviour with two resource values:
1540 MHEffectiveOnTime.FistBin: 3
1541 MHEffectiveOnTime.NumEvents: 12000
1542 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1543 from the resulting gamma candidates
1544
1545 - star: The Center histogram in MHHillas is now by default displayed
1546 with the colz draw-option
1547
1548 - ganymed: now produces valid error codes if failed
1549
1550 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1551 with the option "hadronness" instead of "area" or "both" if
1552 you want to use both cuts. The hadronness cut includes a fixed
1553 cut in hadronness (index 8) and a fixed cut in size (index 9).
1554
1555 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1556 the M3Long of the anti source to be not properly evaluated
1557 (actually is was evaluated as a unique random number) in case
1558 of optimization with anti-theta cut switched on. This might have
1559 lead to improper, but not necessarily wrong, optimization results.
1560
1561 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1562 how to use random forest
1563
1564 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1565 ganymed_onoff.rc. Seems to be unintentional that they were different.
1566
1567 - sponde: Since the introduction of the possibility to define a
1568 normalization energy instead of using the integral the default
1569 was not using the integral anymore but a normalization energy of
1570 1GeV. It is now the integral again.
1571
1572 - sponde: Fixed a problem in the weighting which did not allow
1573 a MC slope of -1.
1574
1575
1576
1577 *** Version 0.9.6 (2006/05/24)
1578
1579 - general: changed the binning of the azimuthal profile of the camera
1580 such that it is aligned with the 60deg boundaries.
1581
1582 - merpp: better handling of problems with the TH, TD part of the
1583 CC-REPORT for files older than 200507190 and 200412210
1584 respectively
1585
1586 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1587
1588 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1589
1590 - callisto: if an arrival time is extracted outside the fadc range is
1591 was set to the boundary before. Now a random number is assigned
1592 instead to avoid unfortunate coincidences of arrival times just
1593 by this arbitrary value.
1594
1595 - callisto: added a new option to callisto.rc which allows
1596 to set the maximum arrival time difference allowed for the
1597 badpixel algorithm to determin whether a pixels belongs to a shower:
1598 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1599
1600 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1601 to 0.9 as suggested by Stefan due to a recent study on the fraction
1602 of pixels surviving the image cleaning
1603
1604 - callisto: switched off error in case of "pulse is too much to the left"
1605
1606 - callisto: The extraction window is not adapted anymore. This means that
1607 the pulse is extracted from the full range. The draw-back is that the
1608 background (pedestal) will become slightly higher. Switching on/off
1609 the PulsePosCheck in the callisto.rc only effects filling the
1610 histograms.
1611 WARNING: If the pulse is too much to the left data is calibrated!
1612 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1613 in the database to make sure that your data is valid!
1614
1615 - star: Show also the number of stars correlated correctly by the
1616 starguider
1617
1618 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1619 than one off-source region in wobble-mode. To use it add the following to
1620 your ganymed_wobble.rc:
1621 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1622 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1623 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1624 + Cut1.ThetaCut: None
1625 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1626
1627 - ganymed: in the case the latest report is older than a default (currently
1628 one minute) and the current report will be skip the starguider
1629 correction and calibration will be reset. The maximum age can be
1630 setup from ganymed.rc by (minutes):
1631 MPointingDevCalc.MaxAge: 1.5
1632
1633 - ganymed: A first implementation showing all size-bins for the theta-sq
1634 resp. alpha-plots in a single tab automatically
1635
1636
1637
1638 *** Version 0.9.5.1 (2006/05/05)
1639
1640 - general: Added a new option "zdiff" to the Makefile which runs
1641 "cvs diff" as "make diff" would do, but with compression
1642
1643 - general: accelerated MTFillMatrix (used for eample in all training
1644 and optimization macros) by skipping some obsolete calles in the
1645 eventloop the first and second loop could be accelerated by ~20%
1646
1647 - general: Added a missing feature in the MFilterList class which
1648 prevented MFEnergySlope from working correctly in trainenergy.C
1649
1650 - general: Accelerated the random forest training and usage a bit
1651
1652 - merpp: Adapted to new raw data file format version 6
1653
1654 - merpp: fixed a problem with reading the starguider reports
1655 after 6.3.2006
1656
1657 - callisto: At some times six pixels had to be exchanged manually in the
1658 data. If the pixels to be swaped are both not found, an error was raised
1659 and calibration was stopped. Now it is assumed they are intentially not
1660 mapped and the Error has been changed to a Warning.
1661
1662 - star: Added new image cleaning based on the arrival time of the shower.
1663 The new cleaning can be accessed using the parameter "Time" instead of
1664 the the old one (like "Absolute) in the star.rc-file.
1665 Recommended parameters:
1666 + MImgCleanStd.CleanLevel1: 8.2
1667 + MImgCleanStd.CleanLevel2: 5
1668 + MImgCleanStd.CleanRings: 2
1669 + MImgCleanStd.KeepSinglePixels: No
1670
1671 - star: Simplified the calculation of the effective on time. By letting
1672 the fit start in the third bin the result should become more stable.
1673 The fit quality is now ignored for the theta-plot which is not used
1674 in the analysis later. Still better pre-cut which, for example,
1675 remove events triggered by car-light (rate changing on a short
1676 time-scale) are missing.
1677
1678 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1679 for optimization (kWeakSource) which is suggested by the Berlin
1680 people for weak sources.
1681
1682 - macros: plotdb.C:
1683 + if no dataset and no time-interval is given only sequences with
1684 an effective on-time above five minutes are plotted anymore
1685 + added a new tab "RelTime" displaying the relative on-time
1686 (effective on-time divided by the observation time)
1687
1688 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1689 the optimization became a lot faster
1690
1691 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1692 To display them just delete the pads displayed on top.
1693
1694 - ganymed: fixed a bug which could cause strange behaviour in wobble
1695 mode if no starguider information was available due to an incorrect
1696 initialization of the starguider calibration
1697
1698 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1699 be changed from within the plot. It can also be setup from the
1700 resource file using:
1701 + MHDisp.fScaleMin: 0.325
1702 + MHDisp.fScaleMax: 0.475
1703
1704 - ganymed, showplot: Fixed a problem with the fit to the off-data
1705 (HistOff) which could cause a time lag or an inifinite loop.
1706 The bug did not effect the results at all.
1707
1708 - sponde: Added a new tab showing the effective collection area after
1709 trigger (including the software trigger)
1710
1711 - sponde: MMcSpectrumWeight has a new option which allows to define
1712 the scaling factor not by the integral of the events but at
1713 a defined energy:
1714 e.g. MMcSpectrumWeight.NormEnergy: 200
1715
1716 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1717 eventloops the loop could be accelerated by ~20%
1718
1719
1720
1721 *** Version 0.9.5 (2006/03/13)
1722
1723 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1724 and added the standard Disp-parametrization
1725
1726 - macros: added a new macro datacenter/macros/plotstat.C allowing
1727 to plot statistics about the data processing
1728
1729 - macros: added a new macro to plot the muon correction coefficients
1730 versus period (macros/plot/mucal.C)
1731
1732 - showplot: path inflation for ganymed files was broken
1733
1734 - callisto: Fixed an important bug. When the number of saturating pixels
1735 were calculated the bad pixel information already available from the
1736 calibration was ignored. This yields wrong values in case pixels
1737 are broken and saturate all the time or randomly.
1738
1739 - callisto: Updated Muon calibration constants. Spline data now also uses
1740 different values for different periods
1741
1742 - star: The time-evolution shown in the effective on-time plot now displays
1743 the axis range (if there are no holes it should be similar to the
1744 effective on-time)
1745
1746 - star: Added two new image parameters:
1747 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1748 the three pixels next to the center of gravity and the size
1749 + MNewImagePar.fConcCore: The ratio of the signals of all
1750 pixels inside or touching the ellipse and the size
1751
1752 - ganymed: now stops in requested source isn't found in catalog file
1753
1754 - ganymed: Many improvements to the phi-plot in wobble mode:
1755 + with a template the ideal background is displayed
1756 + a possible camera inhomogeneity is taken into account
1757 + the anti theta cut is better supported
1758 + the phi cut is automatically calculated from the theta cut
1759 See the examples in ganymed_wobble.rc for more details.
1760
1761 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1762 times the bin-width instead of the absolute energy
1763
1764 - ganymed: New cuts for on/off and wobble mode
1765
1766 - ganymed: The smearing of the False Source plot has been increased
1767 to 0.06
1768
1769 - ganymed: The starguider calibration can now be changed from the
1770 resource file.
1771 See the examples in ganymed*.rc for more details.
1772
1773 - ganymed: added a new option for on-/off-observations
1774 MJCut.RandomSourcePosition
1775 If switched on the distribution of observation time of the source
1776 position in the camera is calculated from the on-data and randomly
1777 applied with this distrbution to the off-data.
1778
1779 - ganymed: by skipping some obsolete calles in the eventloop the
1780 first and second loop could be accelerated by ~20%
1781
1782 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1783 position in the off-data randomly according to its distribution in the
1784 on-data.
1785
1786
1787
1788 *** Version 0.9.4.3 (2006/02/13)
1789
1790 - general: Fixed a bug in most of the programs which prevented the
1791 compile date in the startup message to be displayed
1792
1793 - general: Simplified program calls. The following abbreviations
1794 are now possible:
1795 showlog callisto 55599
1796 showplot signal 55599
1797 star 55599
1798 callisto 55999
1799 ganymed 2
1800 In this cases the corrsponding root-, log-, sequence- or dataset-
1801 filename is automatically compiled using the default datacenter
1802 paths ("/magic/*")
1803
1804 - general: Fixed a long outstanding bug which made axis tick marks
1805 disappear if MDataFormula was used (eg. abs(x))
1806
1807 - general: Updated MMath with new functions to calculate the results of
1808 a exponential, logarithmic and powerlaw fits analytically.
1809
1810 - general: Updated some macros with comments:
1811 + macros/optim/optimdisp.C
1812 + macros/optim/optimenergy.C
1813 + macros/optim/optimwobble.C:
1814
1815 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1816 files) now allows adding a pre-cut like in the optimization. E.g. this
1817 is useful to perform g/h-separation cuts before training the random
1818 forest.
1819
1820 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1821 correctly assigned in the raw data assignement table. A fix to correct
1822 the assignment tabel have been implemented.
1823
1824 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1825 by 90, 180 and 270 deg.
1826
1827 - general: the macro plotdb.C now allows to highlight sequences belonging
1828 to a datset. For more details see the descritions in the macro.
1829
1830 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1831 of the display, it gave wrong results espacially for big sizes.
1832 Now the embedded canvas should always have a ratio width/height=3/2.
1833 The "Size" options have been updated with values fitting the 3/2
1834 size ratio.
1835
1836 - RanForest:
1837 + Updated the random forest classes to support also the
1838 regression method implemented by Thomas H.
1839 + added new tutorial macro how to train the random forest
1840 for energy estimation (macros/optim/rfenergyest.C)
1841 + new classes to train the random forest (still in development)
1842 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1843 + new tutorial macros for random forest training in macros/train
1844 trainenergy.C, traindisp.C, trainseparation.C
1845
1846 - mars: now allows to setup a cut in the resource file mars.rc to choose
1847 the events to be displayed, eg:
1848 Cut.Condition: {0} && {1}
1849 Cut.0: MHillas.fSize>100
1850 Cut.1: MHillas.fSize<900
1851
1852 - merpp: Made aware of the new .rep format 200510250. This includes
1853 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1854 the discriminator thresholds (MCameraTD) and the disciminator
1855 delays (MCameraTD). All of them come with the CC report and are therefor
1856 written to the CC tree.
1857
1858 - callisto: fixed a bug in the calculation of the arrival times in
1859 the Digital Filter. They were all shifted by the same amount
1860 fHiGainFirst. This caused an offset in the order of the position of
1861 the left border of the extraction window in the times calculated
1862 from high-gain and from low-gain. The bug effected only the absolute
1863 arrival times. The bug was there since 30.1.2005.
1864
1865 - callisto: Changed the ExtractionWindow for the pulse position check
1866 such that the camera inhomogeneity becomes as less as possible and
1867 comparable to the pulso position check switched off. More details
1868 on the study will be given at our result web-page.
1869
1870 - ganymed: ganymed.rc, ganymed_onoff.rc:
1871 changed to new cuts trained with 1ES1218 and Crab-data
1872 for maximum sigma*log10(excess)
1873
1874 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1875 a new option was implemented to estimate Disp (CalcDisp)
1876
1877 - ganymed: Implemented two new options which allow
1878 to overwrite the default path to search for the sequence files
1879 --ins=/magic/sequences
1880 and where to search for the image data
1881 --ind=/magic/data/star
1882
1883 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1884 dx/dy from the resource file by
1885 MSrcPosCorrect.Dx
1886 MSrcPosCorrect.Dy
1887
1888 - ganymed: fixed reading the source catalog. Only as many chars
1889 as the requested source name had were compared (If a source
1890 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1891 were requested it could happen that the coordinates of
1892 "1ES1218" were read) The source coordinates are now printed
1893 in addition to its name to the logging output.
1894
1895 - ganymed: changed the background fit in the case of a ThetaSq function
1896 from a polynomial to a exponential, this should give a big improvement
1897 for on-only analysis'
1898
1899 - ganymed/sponde: Calculation of the error of single size-/energy-
1900 bins now uses Li/Ma (5) instead of LiMa (17)
1901
1902 - sponde: Added a plot E^2*dN/dE
1903
1904 - sponde: The energy estimator plot should now show values like
1905 they are commonly used.
1906
1907 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1908 (a powerlaw with cutoff didn't work before)
1909
1910
1911
1912 *** Version 0.9.4.2 (2005/10/01)
1913
1914 - general: added new tutorial macro macros/tutorials/threshold.C:
1915 how to calculate the threshold
1916
1917 - general: added a new game. Start it from the interpreter with
1918 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1919 and MagicReversi)
1920
1921 - general: neighbor pixels in MGeoms are now sorted clockwise
1922
1923 - merpp: made aware of new format 20050829-0
1924
1925 - callisto: New scale factors from muon analysis, stored in new
1926 resource file resources/calibration.rc
1927
1928 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1929 the eventloop if something went wrong. This is necessary for the
1930 automatic processing
1931
1932 - callisto: Implemented a new treatment for the time information
1933 developed by S.Ruegamer, this should give much better response than
1934 the old very primitive algorithm. This is especially important
1935 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1936 treatment was buggy! As neighbor pixels to interpolate the
1937 arrival times always the pixels 0 to 5 were taken)
1938
1939 - callisto: In addition to the new treatment of arrival times the
1940 decision of the treatment whether a pixel contains shower
1941 information or not is used to improve the signal interpolation
1942 further. Previously interpolated pixels showed a non-zero signal
1943 do the peak searching signal extractors. Having a signal pixel
1944 beside raised the signal above the cleaning level. Thus the
1945 pixel survived cleaning to often but with a too low mean signal.
1946 By replacing empty pixels with a gaus (mean and rms from the
1947 corresponding Area entries in MPedPhotCam) this effect can
1948 be supressed.
1949
1950 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1951 got lost when the events were stored by the calibration... fixed.
1952 (This was no problem for normal image cleaning because the pixel
1953 content was artificially set to 0 not surviving standard cleaning
1954 algorithm)
1955
1956 - callisto: Fixed a bug which caused the random and peak-search pedestal
1957 extracted with an extractor to be exchanged for the first (roughly)
1958 500 events (*Extractor and *ExtractorRndm).
1959 (They were simply exchanged in callisto.cc) This bug might have been
1960 introduced in Mars 0.9.4 when the order of calculation of the two
1961 types of pedestal in callisto got exchanged. The bug only effects
1962 the first seconds of data of each sequence.
1963
1964 - star: Taking the arrival time of Muons into account the calculation
1965 of the parameters could be made independant of the noise
1966 (pedestal rms). The dependance was due to the bias of the peak search
1967 extractor. Now only a ZA dependamcy is left which is not yet fully
1968 understood.
1969
1970 - ganymed: The sequences were still not sorted correctly in any case,
1971 because they were sorted by the full qualified path name. Now they
1972 are sorted by their sequence number.
1973
1974 - ganymed: new values for the spark-event-cut
1975
1976 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1977
1978
1979
1980 *** Version 0.9.4.1 (2005/08/18)
1981
1982 - callisto: fixed some problems with the calibration in case of
1983 inteleaved events. Therefor the final and some intermediate
1984 fits are skipped which would take place on partly filled #
1985 histograms and gave wrong results or failed completely.
1986
1987 - callisto: If the intermediate finalization of the histograms
1988 calculating the mean charge of the calibration signal fails
1989 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1990
1991 - ganymed: Fixed some bugs which caused problems in On-only mode.
1992 Still the false source plot doesn't give reasonable results.
1993
1994
1995
1996 *** Version 0.9.4 (2005/08/05)
1997
1998 - general: Fixed the ZA binning. It did not correctly fit the
1999 MC binning
2000
2001 - general: Added a class to correct for the missfocussing in
2002 April (MSrcPosCorrect)
2003
2004 - general: Random Forest energy estimator should now work properly
2005
2006 - general: MHCamera now displays the profiles in deg instead of mm
2007
2008 - general: MH::SetPalette offers a lot of new palettes
2009
2010 - general: MHillas - the case of CorrXY==0 is now handled properly
2011
2012 - general: implemented the possibility to change the line and
2013 marker style of a sky-grid drawn by MAstroCatalog
2014
2015 - general: Runs in sequences and datasets are now automatically
2016 ordered (it is assumed that the order of their filenames correctly
2017 represents the order of observations) to ensure correct reading
2018 of the subsystem data
2019
2020 - general: Runs cannot be added to a sequence twice anymore. Also
2021 Sequences cannot be added twice anymore to a dataset.
2022
2023 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2024 It gave wrong results by 1./2pi
2025
2026 - showplot: got a new option to start a root interpreter, too
2027
2028 - mars: now displays a rough estimate of Disp and the third moment
2029
2030 - mars: now displays the event time MTime if available
2031
2032 - mars: show muon parameters graphically
2033
2034 - mars: now the file to open can be given as commandline
2035 argument
2036
2037 - merpp: Added support for new arehucas version >= 200507190
2038 implementing values for three temperature sensors in the
2039 counting house (MCameraAUX) and the name of the HV settings file
2040 (MCameraHV).
2041
2042 - merrp: Also fixed some problems with wrong versions numbers stated
2043 by arehucas and implemented some fixed for old versions (<200407070)
2044
2045 - callisto: MCalibrationHiLoCam can now be printed from its context
2046 menu, eg in the TBrowser
2047
2048 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2049 - 1.39 (MExtractTimeAndChargeSpline)
2050 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2051 This is important mainly for timing studies.
2052
2053 - callisto: Changed limits in MHCalibrationChargeCalc from
2054 - -100.125 to -98 (fgChargeHiGainFirst)
2055 - 1899.875 to 1902. (fgChargeHiGainLast)
2056 - -100.25 to -99 (fgChargeLoGainFirst)
2057 - 899.75 to 901. (fgChargeLoGainLast)
2058 Introduced new limits:
2059 - fgNumLoGainBlackoutLimit: 0.05
2060 - fgLoGainBlackoutLimit: 3.5
2061 - fgLoGainPickupLimit: 3.5
2062
2063 - callisto: The handling of automatic weights for the digital filter
2064 has been improved. There are now new calibration weights special
2065 for Monte Carlo calibrations.
2066
2067 - callisto: Updated Muon scale with latest results (1% difference
2068 for most data, 5% for Mar/Apr'05)
2069
2070 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2071 was saturated and the blackout-events in the low-gain exceed the
2072 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2073 This excludes those pixels which have a saturating high-gain
2074 channel, but the low-gain switch does not switch often enough
2075 to make the distribution reliable.
2076
2077 - callisto: fix a bug counting the number of saturated events. Up to now,
2078 the number of saturated slices was counted (which is one for a not too
2079 high number), but for some (pathological) pixels, many more slices
2080 saturated and produced wrong limits.
2081
2082 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2083 + MCalibrationRelTimeCam.CheckFitResults: Yes
2084 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2085 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2086 + MCalibrationRelTimeCam.CheckOscillations: Yes
2087
2088 - callisto: introduce max. number of events for intercalibration,
2089 the rest gets skipped. Default: 4096
2090 The calibration causes too many un-reliable pixels if more
2091 than about 5000 events are treated (@500 Hz) because of the
2092 mode hopping of the VCSels. However, in the past, some
2093 calibration runs have been taken (erroneously) with more
2094 than 5000 events, especially the intensity scans where
2095 a good precision is needed.
2096
2097 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2098 photo-electrons for the spline extractor by 1-2% (correctly).
2099
2100 - callisto: The intercalibration is now done using a full f-factor
2101 method instead of a simple update. This makes things slower but
2102 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2103 changes.
2104
2105 - callisto: MPedestalY3 now uses the same extraction range as the data
2106 as calculated by MPedestalY2
2107
2108 - callisto: A check of the fraction of allowed unsuitable (10%) and
2109 unreliable (30%) pixels has been addded when the conversion is
2110 calculated from interleaved events
2111
2112 - star: fixed a bug which caused MEffectiveOnTime containers not to
2113 be written. In the worst case they were skipped almost all, in the
2114 best case they were all ok. It depends on how often the new value
2115 was assigned just with an event which was skipped later by another
2116 task
2117
2118 - star: new histograms MHPointing and MHRate
2119
2120 - star: New tab (Currents) displaying the time evolution of the mean
2121 DC currents
2122
2123 - star: New tab (MeanRms) displaying the time volution of the mean
2124 Pedestal Rms
2125
2126 - star: Output now contains MReportStarguider
2127
2128 - star: Improved muon analysis. Due to the absense of a constant
2129 for the gaus fit for arc width and the fact that the arcwidth
2130 plot was a histogram instead of a profile the resulting psf
2131 became pedestal rms dependant
2132
2133 - ganymed: added new plot (MHPhi) for wobble mode as described in
2134 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2135
2136 - ganymed: corrects now (correctly?) for the misspointing in
2137 May/April 05
2138
2139 - ganymed: Two new default templates for ganymed.rc are avilable:
2140 ganymed_onoff.rc and ganymed_wobble.rc
2141
2142 - ganymed: The first version of MFMagicCuts has been released
2143
2144 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2145
2146 - ganymed, sponde: There are two new options to determin the number
2147 of bins for the signal region (NumBinsSignal) and the number of
2148 total bins (NumBinsTotal) in the MHThetaSq histogram
2149
2150 - ganymed: optimized palettes for MHDisp
2151
2152 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2153 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2154 sqrt(2) to large
2155
2156 - ganymed: The false source plot (MHDisp) is now based on Disp
2157 and a background model determined in the first loop is
2158 subtracted
2159
2160 - ganymed: MFMagicCuts are now available in the cvs. The correct
2161 solution for the disp ambiguity problem is now calculated using
2162 the third moment. The third moment cut therefor is skipped.
2163
2164 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2165 already determined by the third moment along the major axis and
2166 so its actual sign is aligned along the major axis of the shower.
2167
2168 - ganymed: If starguider data is available it is taken into account
2169 when calculating the source position. This is especially important
2170 for wobble data at high zenith angles and culmination data.
2171
2172 - ganymed: If available the starguider data is taken into account as
2173 good as it is possible without a starguider calibration. To switch
2174 it off add
2175 MPointingDevCalc.MaxAbsDev: -1
2176 to your ganymed.rc
2177
2178 - sponde: the zenith angle distribution is now weighted instead of
2179 choosen by default. This gurantees higher statistics in the highest
2180 and lowest energy bins. To switch this behaviour off use...
2181
2182 - sponde: now automatically displays the energy threshold
2183
2184
2185
2186 *** Version 0.9.3 (2005/06/03)
2187
2188 - general: MMcEvt now derived from MMcEvtBasic which should
2189 have no influence on compatibility with older camera files
2190
2191 - general: Implemented a new option to MReadReports which allows
2192 to force reading of the first event of some trees (eg. Drive-tree)
2193 before any other tree.
2194
2195 - general: Made a fix to MPointingPosCalc which assumes that the
2196 run-type is real-data if Process is called before ReInit, such
2197 that also the very first Drive-events in a run are treated
2198 correctly.
2199
2200 - shoplot now displays the filename in the title bar of the window
2201
2202 - merpp: new options: --auto-time-start --auto-time-stop which
2203 allow to cut updating with slow-control at the start- or
2204 (previousle --auto-time only allowed: and) stop-time of
2205 the run stored in the runheader.
2206
2207 - callisto: changed default of fgFallTimeHiGain in
2208 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2209 already set as default in callisto_Dec04Jan05.rc
2210
2211 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2212 now changes the filename for new weights automatically for
2213 cosmics, MC and for different calibration colors.
2214
2215 - callisto: a problem with the order of some code cause the
2216 name of the weights file in MPedestalY2 to be ignored.
2217 Wrongly the calibration_UV weights were used instead
2218 of the cosmics weights set in callisto.rc.
2219
2220 - callisto: should allow ct1 pulser data when the color is
2221 explicitly set also for pretty new runs
2222
2223 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2224 to introduce an additional scale factor (should be around 1)
2225 to adapt for slight deviations in different extractors from
2226 the MC calibration. For MC calibrations the scale factor
2227 is fixed to 1
2228
2229 - callisto: MFCosmics should handle very high signals a bit
2230 more accurate now
2231
2232 - callisto: when calculating the mean pedestal rms for different
2233 pixel sizes or sectors also kUnsuitableEvt is now taken into
2234 account - not only kUnsuitableRun
2235
2236 - callisto: '-raw' option is now the default
2237
2238 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2239 This has the advantage that mean values in the calibration (eg
2240 arrival times) are calculated more accuratly.
2241
2242 - callisto: In the resource file callisto_Dec04Jan05.rc
2243 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2244
2245 - callisto: new Hi-/Lo-Gain intercalibration constants
2246 hilocalib_sp1.root and hilocalib_sp1_mc.root
2247
2248 - callisto: changed default for MJPedestalY2.MaxEvents
2249 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2250
2251 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2252 has changed from 9.0 to 6.0. This is necessary to exclude two very
2253 ringing pixels in September which - when kept - destroy the image
2254 cleaning around them (Markus G.)
2255
2256 - callisto: (!) The Muon analysis of all data taken so far has
2257 suggested that different extractors give slightly different
2258 absolute results after calibration, due to there different
2259 handling of the calibration- and cosmics pulse shape. Although
2260 the over all calibration seems to be a bit to pesimistic (or
2261 the MC seems to be a little bit - 3-5% - too much attenuated).
2262 There for correction factors have been introduced which correct
2263 the calibration constants by
2264 0.956937799 for Digital Filter (callisto.rc)
2265 and
2266 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2267 calibration. The main advantage is, that both data types can
2268 be easily analysed together and compared to the same MC sample.
2269 The factors are choosen such, that the reference is now a
2270 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2271
2272 - star: fixed a bug which caused the first bin of the histograms
2273 vs time to disapear in PostProcess. This gave wrong results
2274 on the screen. The output and all following programs not
2275 directly accessing the histograms haven't been affected
2276
2277 - star, ganymed: Made sure that always the first Drive-tree event
2278 is read and Processed before the first data event was read.
2279
2280 - ganymed: implemented the possibility to replace the standard
2281 false source plot with a different one. For example: If
2282 you want to use a Disp based FS plot use the resource:
2283 NameHistFS: MHDisp
2284 For details about the requirements of these plots look
2285 at the corresponding classes
2286
2287 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2288 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2289 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2290 case MAlphaFitter is setup correctly. For On-Only optimization
2291 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2292 RunOn() instead of Run(). For energy estimation MJOptimize
2293 has been replaced by MJOptimizeEnergy
2294
2295 - sponde: The input MC spectrum can now be weighted to fake a
2296 different spectrum. This is done via MMcSpectrumWeight. For
2297 more details see the class description and sponde.rc
2298
2299 - sponde: The paremeter comparsion plots are not scaled by
2300 their entries anymore. Instead the MC plot is scaled by using
2301 the result spectrum of the analysis. If the input MC spectrum
2302 and the result spectrum has different slopes the absolut
2303 normalization is normally wrong.
2304
2305
2306
2307 *** Version 0.9.2 (2005/05/20)
2308
2309 - general: Changed the default paths for calibrated data and image
2310 files. (The implemented access to these files doesn't yet exist)
2311
2312 - general: support for MRunIter has been removed from the job classes
2313 (use the setter functions of MSeqeunce instead)
2314
2315 - general: ProcessFile has been renamed to Process in all job classes,
2316 because ProcessFile is missleading
2317
2318 - general: The storage of the palette in MHCamera is now possible
2319
2320 - general: new bits describing unsuitable and unreliable pixels have
2321 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2322 kDeadPedestalRms, kFluctuatingArrivalTimes
2323
2324 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2325 versions newer than V200404070
2326
2327 - general: support for cc file versions newer than V200504130. Added
2328 support for active loads (MCameraActiveLoad) and central pixel
2329 (MCameraCentralPixel)
2330
2331 - general: added new histograms for image parameters versus size
2332 (MHVsSize)
2333
2334 - general: The eventloop now automatically calls PrintStatistics
2335
2336 - Status Display: Improved support for printing:
2337 + A default can now be set in .rootrc (for more details see
2338 MStatusDisplay::PrintPS)
2339 + A print dialog is opened so that printer and command line
2340 can be canged
2341
2342 - showlog: improved such that it handles different verbosity levels
2343 more accurate now. This mean you can suppress output when
2344 using showlog.
2345
2346 - showplot: improved
2347 + The new graphics formats have been implemented
2348 (pdf, svg, png, jpg and xpm)
2349 + Implemented an interface for printing. Because you can change
2350 the printing command from the command line you can use all
2351 the nice postscript tool. To print a booklet for example call:
2352 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2353 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2354 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2355
2356 - callisto: fixed a bug in the recognition of the calibration bit
2357 pattern. Concerns only intensity calibration. (The strength of the
2358 intensity has been updated in some cases)
2359
2360 - callisto: add a filter against PIN Diode events when running over
2361 calibration runs since some of the recent calibration runs have
2362 been taken with Pin Diode.
2363
2364 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2365 39943, 44833 in the calibration (MCalibColorSet)
2366
2367 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2368 been set to 1e-18 in callisto_Dec04_Jan05.rc
2369
2370 - callisto: in callisto_Dec04Jan05.rc: set value for
2371 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2372 statistics for the calculation of the mean pulse time
2373 of the cosmisc
2374
2375 - callisto: the charge limit in the calibration has been raised
2376 from 2.5 to 4.5
2377
2378 - callisto: new setup read from callisto.rc
2379 + MCalibCalcFromPast.fNumEventsDump
2380 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2381 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2382
2383 - callisto: MExtractTimeAndChargeSpline extractor:
2384 + The integration ranges were shifted by 0.2 FADC slices to the right.
2385 + unreliable handling of floating point values caused different
2386 results on different platform or with different compiler options:
2387 The new algorithm is numerically exact and more accurate because
2388 it doesn't calculate the integration position by multiple times
2389 adding the step-size (which results in numerical uncertanties
2390 exspecially if multiplied with large numbers)
2391 + A lot of fixes have been introduced which effects integrating the
2392 spline at the edges of the valid range. In this case any memory
2393 was randomly accessed. This behaviour can be tested replacing
2394 all MArrayF by TArrayF which perform a range check (but of course
2395 they are a lot slower)
2396 ! No result obtained with the Spline before can be trusted! Due to
2397 random memory access it might by completely random!
2398
2399 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2400 + extraction range in the high gain to 4.
2401 + weights file to cosmics_weights46.dat
2402
2403 - callisto:
2404 + introduce the check for fluctuating arrival times.
2405 + set charge limit to from 2.5 to 4.5
2406 + introduce asymmetric exclusion due to "deviating number of phes":
2407 Default: -9.0 +4.5
2408 + make deviating number of phes unsuitable (see David's findings).
2409
2410 - callisto: fixed the display of unsuitable pixels. The old change
2411 to a real profile in MHCamera broke it.
2412
2413 - callisto: The cosmics filter is used in MJCalibration now
2414 independant of the pulser color (formaly it was used only for
2415 CT1-pulser data). The threshold of number of max empty pixels
2416 has been raised from 2% to 5% in MJCalibration. The maximum
2417 fraction of rejected event is 50% otherwise the calibration has
2418 failed. The filter now ignores unsuitable pixels.
2419 Setup the filter from callisto.rc using "ContCosmics"
2420 (see MFCosmics::ReadEnv)
2421
2422 - callisto: changed default for fgOffsetFromLogain back
2423 from -2.8 to -1.8 in digital filter.
2424
2425 - callisto: for the common extractors
2426 + MExtractFixedWindow
2427 * MExtractTimeAndChargeSlidingWindow
2428 * MExtractTimeAndChargeSpline
2429 * MExtractTimeAndChargeDigitalFilter
2430 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2431 and fResolutionPerPheLoGain
2432
2433 - callisto: Updated the hi-/lo-gain intercalibration constants
2434 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2435 hilocalib_df6.root
2436
2437 - callisto: The default lo-gain extraction window for the
2438 MExtractTimeAndChargeSlidingWindow extractor has been increased
2439 from 6 to 8 to take the stretch of the pusle into account
2440
2441 - callisto (!!!): fixed an important bug in the setting of the
2442 incoming pedestal pointer to the signal extractor extracting
2443 pedestals. This bug caused the pedestals not to be subtracted
2444 correctly in the calibration afterwards. The effect was about 10%
2445 too high conversion factors for the digital filter and the spline
2446 and more than 40% for the sliding window.
2447 The bug existed since end of February! (Markus G.)
2448
2449 - star: added muon support to star. A new tab "MHMuonPar" is
2450 displayed. The lower right plot is an estimate of the point spread
2451 function. A reference value is displayed. To get the real PSF
2452 you must compare with MC. The setup for the muon analysis
2453 is done in star.rc. More informations can be found in
2454 MHSingleMuon and MHCalibParCalc
2455
2456 - star: The weather data is now displayed in star
2457
2458 - star: MEventRateCalc handles the calculation of the event rate more
2459 accurate now in case of the start of a new run inside a sequence
2460
2461 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2462 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2463 changed only minimally
2464
2465 - ganymed: (MJCut and MJOptimize) now displayes the number of
2466 excess events versus size. The energy estimation is done in
2467 MJSpectrum (sponde)
2468
2469 - ganymed: got support for using other variables than Alpha, eg. Theta.
2470 Therefor you need a class deriving from MHAlpha which supports
2471 this variable (one is already existing: MHTheta, which is now the
2472 default in ganymed). It is setup through ganymed.rc
2473
2474 - added a full featured spectrum program (sponde) which reads
2475 ganymed output and monte carlos and compiles a spectrum
2476
2477
2478
2479 *** Version 0.9.1 (2005/04/14)
2480
2481 - Fix bug on the arrival time reconstruction when using Digital
2482 Filter (in some marginal cases (10%) times were reconstructed shifted
2483 by 0.2 slices)
2484
2485 - all executables now return 2 where in previous versions -1 has
2486 been returned (gave problems with shell-scripts)
2487
2488 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2489 also done with a intercalibration input file
2490
2491 - a bug in the time fine adjustment of the digital filter has been fixed
2492
2493 - a lot of small fixes to calling TPad::Divide with a margin==0
2494
2495 - MStatusDisplay now shows the memory usage
2496
2497 - added a memory leak statistic after the eventloop
2498
2499 - MHadronness replaced by MParameterD
2500
2501 - MEnergyEst replaced by MParameterD
2502
2503 - wobble mode can now be switched on from the data-set
2504
2505 - switched on bad pixel detection for a pedestal level
2506 which is more than 5 times the variance
2507
2508 - Fixed default paths to be correct for the new data center
2509
2510 - Fixed handling of drive data. The pointing position in now
2511 copied to MPointingPos inside star for real and MC events
2512
2513 - made sure, that the sequences in a dataset are sorted by
2514 their number to ensure the correct synchronization
2515
2516 - added all resource files necessary to handle spline extraction
2517 of signal for the late 2004 and the early 2005 data
2518
2519 - update the reference lines for the december data
2520
2521 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2522 This is important for the Dec. and Jan. data where the calibration
2523 pulse position changes much.
2524
2525 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2526 filter. This corrects only an defective extraction of the MC at
2527 low-gain signals lower than 90 phes.
2528
2529 - fixed some slowdown in calibrating data with interleaved events from
2530 Jan and Dec. As a workaround made the pretty palette the default.
2531 The inverse Deep Blue Sea has a bug which slows down long calibration
2532 runs a lot.
2533
2534 - implemented new values from new starguider report as defined
2535 in TDAS00-07 V7.1 (eg SkyBrighness)
2536
2537 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2538 in starguider report (If you merpp the same reports with this version
2539 you'll get the correct units (arcmin) but a different result
2540 than with old versions (wrong units))
2541
2542 - Now the status display can also write PNG, JPEG and XPM (other file
2543 formats are still unsupported by root)
2544
2545 - added a lot of scripts and macros in directory datacenter used
2546 for automatic processing
2547
2548
2549
2550 *** Version 0.9 (2005/03/23)
2551
2552 - Calibration is now done autmatically into photo-electrons like
2553 decided by the Collaboration Board
2554
2555 - Reference lines in the display can be read from resource file
2556
2557 - Interlaced calibration events can be handled by callisto
2558
2559 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2560 and applied in callisto.
2561
2562 - class MJCalibTest can be called by callisto
2563
2564 - callisto can now run with three data types: rawdata, rootdata, MC
2565
2566 - added two classes mreport/MReportStarguider.cc and
2567 mreport/MReportStarguider.h for implementing starguider-data
2568
2569 - the output of merpp-update now contains starguider information:
2570 MReportStarguider and MTimeStarguider
2571
2572 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2573 values were lower than they should. This was more visible for high
2574 energy (Size) events.
2575
2576 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2577
2578 - added a new loop to callisto to support the correct extraction of
2579 the pedestal and pedestal rms through the signal extractor
2580
2581 - added class to perform fourier tranformation of a hexagonal structure
2582 (MHexagonalFT)
2583
2584 - added class to perform fourier tranformation of a hexagonal structure
2585 in a tasklist (MHexagonalFTCalc) example: hft.C
2586
2587 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2588 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2589 small pixels, example: extendcam.C
2590
2591 - added possibility to write data to memory (TTree) using MWriteRootFile
2592
2593 - added possibility to read a TTree stored only in memory by MReadTree
2594
2595 - new classes to deal with the interleaved calibration events:
2596 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2597
2598 - implemented filters to callisto to skip calibration events
2599
2600 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2601 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2602 the slices by statistics
2603 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2604 signal extractor without randomization
2605 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2606 with the signal extractor with randomization (extraction window is
2607 randomly fixed)
2608 The three kind of pedestal is not yet implemented (for speed reasons) as
2609 long as nobody really needs it:
2610 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2611 extracted with the signal extractor with randomization
2612
2613 - callisto now finds the pulse position in the data automatically
2614
2615 - implemented data reduction in calibrated data by reducing the precision
2616 of the stored floating point values (pedestal, rms and signal) to
2617 roughly 0.5%
2618
2619 - fixed showplot to make file format conversion (eg. converting a
2620 status display stored in a root file into a postscript file) in
2621 batch mode possible:
2622 showplot -b --save-as-ps[=outfile.ps] infile.root
2623
2624 - Allow class names as part of filter rules, eg
2625 (MFSupercuts) && (MHillas.fSize>100)
2626
2627 - fixed a lot of stuff to allow all programs to process MonteCarlo
2628 camera files.
2629
2630 - enhanced possibility to debug reading of resource file
2631
2632 - MDataChain should handle priorities of operator more
2633 accurate now
2634
2635 - completely revised the container in which the signal is stored
2636 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2637 * the new implementation is faster and
2638 * needs less storage space
2639
2640 - FIRST version which can process Monte Carlos through the
2641 whole chain of programs (callisto, star, etc)
2642
2643 - implemented new image parameters for the border length of
2644 the shower image (MNewImagePar2)
2645
2646 - implemented wobble-mode in ganymed
2647
2648 - new class (MJOptimize) taking care of all optimization processes
2649
2650
2651
2652 *** Version 0.8.6 (2004/10/05)
2653
2654 - New combined signal and time extractor
2655 MExtractTimeAndChargeDigitalFilter
2656
2657 - The Report for the trigger section in the CC run summary has been
2658 updated, and now the IPRs (Individual Pixel Rates) are available.
2659
2660 - new macros for database interaction: filldotrun.C, filldotrbk.C
2661
2662 - added new program which can convert colored output which was redirected
2663 into a file back into colored text (for example to display it with
2664 more): showlog
2665
2666 - added new program to display an MStatusArray of plots (stored with
2667 MStatusDisplay) from a file: showplot
2668
2669 - Added support for Sequences (MSequence). Sequences are blocks of run
2670 files containing the same calibration and belonging to the same
2671 source
2672
2673 - Added a new task (MTaskEnv) which can be used in setup files to switch
2674 between different tasks (for example to choose a signal extractor)
2675
2676 - Implemented automatic file splitting in MWriteRootFile
2677
2678 - After image cleaning an island index is assigned to all used pixels.
2679 The index corresponds to the order of the islands in size.
2680
2681 - added a cleaning which takes signal height _and_ arrival time into
2682 account: probability cleaning (for more details see MImgCleanStd)
2683
2684 - added a cleaning which takes takes the absolute number of photons
2685 times the area ratio as cleaning level
2686 (for more details see MImgCleanStd)
2687
2688 - Changed calculation of image parameters such, that it can be done
2689 for all used pixels or the pixels with a defined island index only
2690
2691 - implemented new image parameters displaying the number of islands,
2692 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2693
2694 - event display in executable changed to support also calibrated files
2695 (done with MJCalibrateSignal)
2696
2697 - added program doing the calibration and the signal extraction
2698 and signal calibration: callisto Most part of the setup is done
2699 by a resource file: callisto.rc
2700
2701 - implemented support for pixels with negative IDs (Raw file format
2702 version 4)
2703
2704 - implemented an new option in merpp (--auto-time) to get the time
2705 range for cc and/or caco data from the run header of the raw data
2706
2707 - New star-program (star and MJStar). Taking calibrated data from
2708 callisto/MJCalibrateSignal as input. The setup is done through
2709 a resource file: star.rc
2710
2711 - Added possibility to setup the eventloop in the mars-executable
2712 Camera Display by a resource file: mars.rc
2713
2714 - The the mars-executable Camera Display can now also read
2715 calibrated data files written by callisto/MJCalibrateSignal
2716
2717 - Added a new class which can calculate the source position in
2718 the camera from a pointing model known to be correct and
2719 the pointing model used for observations (MSrcPosFromModel)
2720
2721 - added a new version of the class calculating the effective on-time
2722 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2723 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2724 MHTimeDiffTheta.
2725
2726 - added the possibility to count how often a signal is above (or
2727 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2728 can replace MHTriggerLvl0)
2729
2730 - added ore convinient ways to set the axis-titles of your histograms
2731 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2732 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2733
2734
2735
2736 *** Version 0.8.5 (2004/08/06)
2737
2738 - new Signal Extractors: MExtractFixedWindowSpline
2739 and MExtractAmplitudeSpline
2740
2741 - implementes interleave in merpp to be able to merpp parts of a file
2742
2743 - implemented force-functionality to merpp
2744
2745 - star display to display star catalogs (MAstroCatalog)
2746
2747 - star display to 'mirror' stars to the camera (MAstroCamera)
2748
2749 - implemented a new cleaning option which allows cleaning scaled with
2750 the real ratio of the rms depending on the pixel size, not only the
2751 square root of the pixelsize (MImgCleanStd, MCameraData)
2752
2753 - removed obsolete MBlind* classes
2754
2755 - Signal extractor taking the AB flag into account implemented (this makes
2756 an odd number of slices for signal extraction possible
2757 (MExtractSignalABcorr)
2758
2759 - implemented a class extracting the pedestal from the raw-data (events)
2760 itself using empty lo-gain (MpedCalcFromLoGain)
2761
2762 - Added mean values to MPedPhotCam
2763
2764 - Added Makefile for Darwin (this OS is NOT officially supported!)
2765
2766
2767
2768 *** Version 0.8.4 (2004/04/19)
2769
2770 - new fast arrival time extractor using cubic splines:
2771 MExtractTimeFastSpline
2772
2773 - implementes multi-argument support in MDataChain
2774 ("pow(a, b)")
2775
2776 - implemented double reference support in MDataChain
2777 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2778
2779 - added support in MF for expressiond like
2780 "MHillas.fWidth<2*<MHillas.fLength"
2781
2782 - MDataChain is now able to support variables like [0], [1], ...
2783 which can be used in fit functions as parameters. The interface
2784 is implemented through the new virtual function
2785 MParContainer::SetVariables
2786
2787 - added new class MArrivalTimeCam/MArrivalTimePix:
2788 Storage containers to hold the ArrivalTime of the camera/pixel
2789
2790 - added new classes for the calibration of relative arrival times:
2791 MCalibrationRelTimePix and MCalibrationRelTimeCam
2792
2793 - added new classes to extract the signal of the blind pixel and the
2794 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2795
2796 - added new classes for the bad-pixels treatment (MBadPixels*)
2797 which are more powerfull than the old ones (MBlindPixel*)
2798 and will replace them.
2799
2800 - added filter against cosmics: MFCosmics
2801
2802 - added new class MArrivalTimeCalc2:
2803 Calculates the arrival time as the signal weighted mean of the time
2804 slices in the maximum window
2805
2806 - added a new macro call pointspreadfucntion.C that fits with a 2D
2807 gaussian the DC spot for an star. It gives you the RMS of
2808 the PSF and the center of the star, very useful for misspointing
2809 studies.
2810
2811 - added support for multi-telescope camera files. Added classes
2812 MStereoCalc and MStereoPar, classes to calculate and store shower
2813 parameters calculated from the data of two telescopes, for the MC
2814 studies regarding the MAGIC clone.
2815
2816 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2817 MC data calibrated in photons instead of ADC counts.
2818
2819 - added three macros to show the calibration and analysis chain of
2820 MC data. The macro starmc.C does both calibration and analysis, producing
2821 an output containing Hillas parameters for each event. The macro
2822 mccalibrate.C does just the calibration and writes out a file containing
2823 pixel information in photons instead of FADC data. The macro starmc2.C
2824 reads in such a file and produces an output with Hillas parameters.
2825
2826 - added MPedPhotCalc to compute pedestals in units of photons, see
2827 macro pedphotcalc.C
2828
2829 - added all class to perform the calibration, see macro calibration.C
2830
2831 - added class MFFT to perform Fast Fourier Transforms
2832
2833 - added class MSimulatedAnnealing to perform simulated annealing
2834 minimizations
2835
2836 - added new macro bootcampstandardanalysis.C which holds the skeleton
2837 of the analysis chain discussed in the december bootcamp.
2838
2839 - added support for DAQ raw data file format V2
2840
2841 - implemented an arbitrary time stamp for the events from raw-data
2842 files with file version<3. It is calculated from the run number,
2843 the date of start and the FADC clock tick from the first module
2844
2845 - implemented the correct decoding of the event time-stamp
2846 coming from the DAQ for raw-data files with file-version>2
2847
2848 - added a new classes storing the pedestals in units of photons:
2849 MPedPhotPix, MPedPhotCam
2850
2851 - added support for DC current files from the camera control
2852
2853 - added support for start- and stop-time when merpping report files
2854
2855 - added MReportCC storing the weather data from the CC-REPORT
2856
2857 - added class to fill trainings and test matrices (MTFillMatrix)
2858
2859 - added a filter performing a software trigger (MFSoftwareTrigger)
2860
2861 - Added classes to perform parts of the standard analysis (Jobs):
2862 + MJPedestals
2863 + MJCalibration
2864 + MJExtractSignal
2865 Note: All of them are preliminary!
2866
2867 - Added Iterator to iterate over files giving only the run-number
2868
2869 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2870 the evolution of a sector vs time
2871
2872
2873
2874 *** Version 0.8.3 (2003/12/05)
2875
2876 - adapted Random Forest classes to allow the use with MC
2877 multi-telescope files which can be produced with the coming
2878 camera version 0.7.
2879
2880 - added classes to read and interprete central control report files
2881 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2882
2883 - enhanced merpp (the executable) to support .raw and .rep files.
2884
2885 - added classes for light calibration (MCalibration* and
2886 MHCalibration*) by Markus Gaug. Further work has to be and will
2887 be done soon.
2888
2889 - Added a preliminary 'synchronizer' (MReadReports) which will
2890 replace MReadMarsFile as soon as it is finished.
2891
2892 - Added a tutorial macro demonstrating how report files are merpped
2893 and how they can be read from the root file in the correct order
2894 of time (readrep.C)
2895
2896 - Added a generalized histogram (similar to MH3) called MVsTime
2897 which allows to plot variables (or rules - MDataChain - of
2898 variables) vs time. For an example have a look at tempvstime.C.
2899
2900 - Changed the name of the event trees:
2901 + Events --> Events
2902 + PedEvents --> Pedestals
2903 + CalEvents --> Calibration
2904
2905 - changed name of MTime in the event trees from MRawEvtTime to MTime
2906
2907 - added displaying the sector indices to the mars event display
2908
2909 - Magic Online Analysis (MOnA) implemented in a first version
2910 (see mona.cc, MOnlineDump and MOnlineDisplay)
2911
2912 - added classes to calculate event rate
2913 (preliminary: MEventRateCalc, MEventRate)
2914
2915 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2916
2917 - added classes dealing with the telescope pointing position (MPointing*)
2918
2919 - implemented the 'final' Mars time stamp based on some experiences with
2920 the new 'Synchonizer'
2921
2922
2923
2924 *** Version 0.8.2 (2003/11/10)
2925
2926 - accelerated standard analysis by a factor of 6-8 ...
2927 + doing precalculations in MGeomCam for the pixel area ratio
2928 + creating a look up table for the single pixels in MCerPhotEvt
2929
2930 - added task to calculates weights in case you want to 'change'
2931 the energy spectrum of a monte carlo file
2932 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2933
2934 - added a new executable star which implements the
2935 star.C macro as precompiled executable. Currently a flexible
2936 setup is not possible, but a 'input card' setup will follow.
2937
2938 - Starting to implement Multi-Telescope-Support based on the
2939 upcomming camera version 0.7. The base for a general support
2940 is implemented and the star-functionality is proven to work.
2941
2942 - Replaced Event-Display in and Camera-Display in the Mars GUI
2943 executable by a more convinient display base on MStatusDisplay.
2944
2945 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2946
2947
2948
2949 *** Version 0.8.1 (2003/10/20)
2950
2951 - added signal subtraction for pure on data by means of fitting
2952 the background in the off region or by performing a combined
2953 signal/background fit. Provides necessary histograms for
2954 obtaining energy spectra and a light curve.
2955
2956 - added classes to perform and study the selection of the
2957 2nd Level Trigger on MC data (example in triglvl2.C macro)
2958
2959 - added pedestal calculation
2960
2961 - implemented "democratic cleaning" (tail cut value proportional
2962 to pixel area) according to Wolfgang's suggestion.
2963
2964 - added Sigmabar treatment (calculation and basic histogramming)
2965
2966 - added basic routines to apply padding
2967
2968 - added first implementation of MARS-based source visibility plotter
2969 (needs to be linked against slalib, preliminary version)
2970
2971 - enhanced functionality of data chains: random numbers, conversion
2972 functions and access to MHMatrix objects
2973
2974 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2975 numbers under certain circumstances (runs with 0 events included)
2976
2977 - fixed a bug in the general filter MF (didn't work on some systems
2978 at all)
2979
2980 - fixed a bug in chaining files, which caused the analysis to crash or
2981 ignore files
2982
2983 - implemented more geometry classes describing the parameters used
2984 to simulate the PMT camera
2985
2986 - added new Monte Carlo classes containing the setup of the different
2987 programs in the MC chain.
2988
2989 - added a (preliminary) general task to evaluate chi-square of a given
2990 parameter in an eventloop.
2991
2992 - first implementation of a container describing the observatory
2993 location (Long, Lat, etc)
2994
2995 - added Random Forest - method for g/h-separation
2996
2997 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2998 (this means, that it is compiling, but not yet fully tested)
2999
3000 - added a new status display which can show the present status
3001 of histograms while an eventloop is running (MStatusDisplay,
3002 an example can be found at status.C)
3003
3004 - reorganized directories:
3005 classes describing the image --> mimage
3006 classes containing Monte Carlo Histograms --> mhistmc
3007 classes for Random Forest method --> mranforest
3008
3009 - added (event-)weights to fill histograms
3010
3011 - colors in logging output to screen
3012
3013 - changes to the Image Parameter declaration:
3014 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3015 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3016 + MHillasExt now derives from MParContainer instead of MHillas
3017 --> Files written with the old definition are more or less unreadable
3018
3019 - reading of reflector files
3020
3021 - display data from reflector files in the camera
3022
3023 - implemented currents (and display them in the camera)
3024
3025 - logarithmic scale in camera
3026
3027 - added class to iterate through directory contents (MDirIter)
3028
3029
3030
3031 *** Version 0.8 (2002/11/18)
3032
3033 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3034
3035 - corrected 48(!) wrong entries in the Next Neighbor table of the
3036 Magic Camera (all in the inner part of the outer ring, mostly
3037 missing a single NN)
3038
3039 - Fixed a bug in the table describing the Next Neighbours of the
3040 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3041 have any neighbour)
3042
3043 - changed trigrate.C: now it calculates the pure NSB triggers from
3044 a camera file (generated with no showers), so there is no need
3045 to introduce them by hand in the BgR array (for more details
3046 please ask Abelardo)
3047
3048 - added MHHadronness (and MHadronness) as a general facility to evaluate
3049 the quality of a gamma-hadron seperation method
3050
3051 - changed MWriteAsciiFile to accept rules (MDataChain)
3052
3053 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3054 must be replaced by calles to MWriteAsciiFile::AddColumn and
3055 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3056 changed.
3057
3058 - Implemented generalized event-matrices (one row per event)
3059 (MHMatrix)
3060
3061 - implemented the one dimensional composite probabilities
3062 (MHCompProb, MCompProbCalc, comprob.C)
3063
3064 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3065 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3066
3067 - Added a camera display displaying the pixel numbers to the
3068 event display gui.
3069
3070 - Added Monte Carlo Informations to event display gui
3071
3072 - Changed the camera display to display the pixel numbering
3073
3074 - Added three buttons to the camera display to change the palette
3075
3076 - Added the number of used and core pixels after image cleaning
3077 to MHillas
3078
3079 - Changed the algorithm used in MHillas according to TDAS 02-03
3080
3081 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3082
3083 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3084
3085 - Added fCosDeltaAlpha to MHillasSrc
3086
3087 - The numbers of photons used to calculate fConc and fConc1 in
3088 MHillasExt are now scaled with the pixel size, so that one get
3089 a four times smaller value for the bigger pixels in the outer ring.
3090
3091 - added new task to smooth the camera contents (MCameraSmooth)
3092
3093 - added possibility to use interpolated pixel values for blind pixels
3094 instead of removing it completely from the analysis
3095
3096 - Implemented the possibility to save the whole eventloop with
3097 its setup to a file. This information can be read and from
3098 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3099 and MEvtLoop::MakeMacro. If you find something not working, please
3100 report - this stuff is still in a beta phase.
3101
3102 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3103 file having crab starfield, but also for all following files - fixed
3104
3105 - MTaskList::PrintStatistics can now be instructud to print also the
3106 title, too: use PrintStatistics(0, kTRUE)
3107
3108 - Changed the image cleaning so that pixels with to many 'used'
3109 neighbors are left used (to get rid of 'holes' in events)
3110
3111 - Introduced more output to the camera displays
3112
3113 - Added an array of histograms (eg one hist per run), MHArray
3114
3115 - Added a _preliminary_ version of the reader for CT1 PreProc files
3116 (MCT1ReadPreProc)
3117
3118 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3119 (thanks to Raquel)
3120
3121 - added the first energy estimator (MEnergyEstParam, estimate.C,
3122 estfit.C) using a parametrization
3123
3124 - Added some new Monte Carlo paremeter containers used to store
3125 setup information from the MC chain (MMcConfigRunHeader,
3126 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3127
3128
3129
3130 *** Version 0.7 (2002/04/30)
3131
3132 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3133 the pedestal mean value was saved incorrectly. For files from
3134 this versions we substract 0.5 from the pedestal mean.
3135 WARNING: This may effect your results, so don't wonder...
3136
3137 - First implementation of an algorithm using only triggered events
3138 for the collection area calculation
3139
3140 - Ascii Output can now also be used for parameter containers which
3141 doesn't overload MParCointainer::AsciiWrite
3142
3143 - The Ascii Output is now also capable of writing single data members
3144 of one container
3145
3146 - You are now able to change the order of the values written to the
3147 ascii file
3148
3149 - You can now specify a conversion factor for each data member written
3150 to an ascii file. This may be usefull to change the units of the
3151 data member (eg. degrees instead of millimeters in case of the
3152 hillas parameters)
3153
3154 - Replaced old MHillas by a new structure which allows you to extend
3155 the parameters stored in MHillas very easily:
3156 see MHillas and MHillasExt
3157
3158 - Added classes to handle source dependancy of image parameters:
3159 see MHillasSrc
3160
3161 - Added container (MBinning) to have a standard input for the binning
3162 in different histograms (eg. the Energy bins should be the same in
3163 all histograms)
3164
3165 - Changed Hillas histograms from mm to deg
3166
3167 - Added the flexible binning to the hillas histograms
3168
3169 - Added a filter for the alpha parameter (MFAlpha)
3170
3171 - It is now possible to write single data members of a class object to
3172 an output stream instead of the whole container only
3173
3174 - Added a generalized filter for a data member:
3175 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3176
3177 - Added a generalized Filter parser for more difficult filter rules
3178 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3179
3180 - Added new Monte Carlo histograms:
3181 MHMcEnergyImpact and MHMcEfficiency
3182
3183 - Added many new histograms needed for the flux calculation.
3184
3185 - Added a generalized histograms which can fill and show up to three
3186 data members in either a one-, two- or three-dimensional histogram, eg:
3187 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3188
3189 - Added:
3190 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3191 * calculation of <Theta> as a function of time (MHThetabarTime)
3192 they are needed in the flux calculation in
3193 order to select for a given bin in Theta (or time) the appropriate
3194 effective collection area, which is assumed to be given as a function
3195 of Theta and the true energy
3196
3197 - Added calculation of the migration matrix in the energy
3198 (MHMcEnergyMigration):
3199 the migration matrix describes the migration from the true (E_true)
3200 to the estimated energy (E_est); it is needed to determine the
3201 distribution of E_true from the measured distribution of E_est
3202 by unfolding
3203
3204 - changed the color palette in the camera display to DeapSea.
3205
3206
3207
3208 *** Version 0.6 (2002/01/15)
3209
3210 - Introduce the option of disable pixels (MBlindPixels and
3211 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3212 able to deal with Star Field NSB.
3213
3214 - Fixed a bug in the pedestals substraction
3215
3216 - Introduced verbosity levels
3217
3218 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3219
3220 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3221 work correctly (thanks to Abelardo)
3222
3223 - Introduced correct treatment of the diffuse Night Sky Background
3224 and NSB (MMcPedestalNSB)
3225
3226 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3227
3228 - Introduced MMcRunHeaders which contains monte carlo run informations
3229
3230 - Added a 'Print'-Task (MPrint) which calls the Print function
3231 of a parameter container for each event
3232
3233 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3234
3235 - changes to be more efficient with root 3.02/06
3236
3237 - root 3.02/06 fixes:
3238 + the memory leak when reading MRawEvtData
3239 + loosing more time than necessary to update the progress bar
3240
3241 - MWriteAsciiFile is now capable of writing more than one container
3242 in a line. For example: To be able to write Monte Carlo and
3243 Hillas values (energy and alpha) in one line.
3244
3245
3246
3247 *** Version 0.5 (2001/11/06)
3248
3249 - Added new GUI functionality (Analysis)
3250
3251 - Added a camera display to be able to display events in the camera
3252 together with the calculated hillas ellipse
3253
3254 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3255 object at any state of the analysis, so that the output are several
3256 states
3257
3258 - Fixed a bug in the collection area error calculation
3259 (Thanks to Ciro and Abelardo)
3260
3261 - Fixed a bug which causes merpp to crash in some environments
3262
3263 - Implemented auto enabling scheme for Branches to speed up reading
3264 a lot (see MReadTree and MTask)
3265
3266 - Fixed a bug in the Histogram classes which caused histograms to
3267 be written to a file by MWriteRootFile without request
3268
3269 - changed the object I/O from the old stylish root I/O to the new
3270 'auto evolution scheme' This was done only for classes which are not
3271 yet used in Monte Carlo files, so that these files are still readable.
3272
3273 - Added support for a progress bar in MEvtLoop and MReadTree
3274 (see the Analysis Window in Mars for an example)
3275
3276 - Fixed a bug in the package creation which disturbed the conversion
3277 between a mars version unpacked from a tar file and the repository.
3278
3279 - Changed the code to writer merpped (converted into root format)
3280 raw files, to get faster (around 10%)
3281
3282
3283
3284 *** Version 0.4 (2001/09/20)
3285
3286 - This release is made to compile on a root version >= 3.00
3287
3288 - Fixed a bug which causes MReadTree to read the first file only
3289
3290 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3291
3292 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3293
3294 - Added a task to write several container to a root file (MWriteRootFile)
3295
3296 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3297
3298 - Added calculation of the collection area (MMcCollectionAreaCalc)
3299
3300 - fixed some bugs in the Hillas calculation
3301
3302 - added filters to be able to control the task execution dependent on
3303 a parameter (for example: the number of level 1 triggers in a MC-file)
3304
3305
3306
3307 *** Version 0.3 (2001/04/23)
3308
3309 - Many demo macros added
3310
3311 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3312
3313 - Hillas Calculation added
3314
3315 - Standard image cleaning available
3316
3317 - MReadTree is now able to handle more than one file
3318 (Remark: of the same structure)
3319
3320 - Now we are able to display events in a first version of the
3321 Camera event display. To do this we must run the macro
3322 "macros/readCT1.C" to read data from CT1.
3323
3324
3325
3326 *** Version 0.2 (2001/01/24)
3327
3328 - First Implementation of a Gui to read the raw data. Start the
3329 gui with the command mars.
3330
3331
3332
3333 *** Version 0.1 (2000/12/20)
3334
3335 - First official release 0.1
3336
3337 - Changes:
3338
3339 + changed calling style of MRawPixelIterator from do...while to
3340 while-loop
Note: See TracBrowser for help on using the repository browser.