source: trunk/MagicSoft/Mars/NEWS@ 9482

Last change on this file since 9482 was 9482, checked in by tbretz, 15 years ago
*** empty log message ***
File size: 135.2 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 * Added consistency check for two consecutive runs
11
12 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
13 has been disconnected and the L1 (L1TPU) has directly been connected
14 to another bit in the trigger pattern. This has been fixed by an
15 update of the decoding. Both bits are now or'ed together.
16
17 * Added a new camera layout MGeomCamFact which is the "four rectangular
18 pixels ordered in a hexagonal geometry" layout
19
20 * All programs now store the command line as TNamed "CommandLine"
21
22 ;showplot:
23
24 * If a file without a MStatusArray is opened all object (not just
25 canvases) found in the file are drawn. Note that this may result
26 in empty tabs.
27
28 ;ceres:
29
30 * The night sky noise is now scaled with the sensitive area and
31 is given in units per square centimeter
32
33 * Added the possibility to add a cut after the image parameter
34 calculation (''Cut'')
35
36 * updated the PDE of the GAPDs with a more reliable curve from
37 the meeting page (linear extrapolate below 350nm)
38
39 * The impact distribution in the event distrbutions is now
40 perpendicular to Alt/Az and the histogram is displayed in 1D
41
42 * The GAPD PDE has been updated
43
44 * PDEs and mirror reflectivities have been linearily extrapolated
45 to match the wavelegth range between 290nm and 900nm
46
47 * There is no default pulse shape anymoe it must be given in
48 the resource file
49
50 * Fixed a bug which caused the aerosol coefficient to be incorrectly
51 initialized. The effect might be random but seems to be small.
52
53 * Now accepts sequence files as input
54
55 * creation of pedestal and calibration files is now steered by
56 --mode (see ceres help)
57
58 * Instead of initializing the whole G-APD chip (all cells) before
59 each event (which is rather time consuming) a time evolution before
60 each event is now simulated which is enough to recovere every cell
61 to 99.999% of its response taking the background rate into account.
62 This is in total about a factor of ten faster and should not be
63 less accurate because under normal conditions the recovering cells
64 and the newly hitten cells will hardly be identical (due to
65 statistical reasons)
66
67 * improved the trigger algorithm which is now faster and allows easily
68 for multiplicity triggers
69
70 * The PDC flag in the file name is now correctly written
71
72 * A "PreCut" has been added which can be used after reading the events
73 to select them even before any calculation is done.
74
75 ;merpp:
76
77 * The new drive reports which contain also the status of the starguider
78 are now implemented, but the starting date (17/05/09) is preliminary.
79
80 ;callisto:
81
82 * Fixed a bug which prevented MAGIC Monte Carlo file from being
83 calibrated (ceres files worked)
84
85 ;star:
86
87 * allow to run thru even if discriminator threshold are missing
88 (they are not used for analysis so far anyway)
89
90 ;ganymed:
91
92 * added new starguider calibration for sequences since 1000534
93
94 ;database:
95
96 * added possiblity to query/plot data from certain source (with
97 regular expressions) in plotdb.php
98
99 * new feature in showplots*.php: on mouse-over additional information
100 on the sequence is displayed
101
102
103
104== Version 2.3 (2009/03/07) ==
105
106 ;SUGGESTION
107
108 * There is no need to re-run any data because no change took place which
109 could have an effect on the output. However, if you want a
110 meaningful SrcPos plot for your MCs in sponde you must re-process
111 star for your MCs first.
112
113 ;REMARK
114
115 * File produced with this release containing a camera geometry (which
116 are basically all files were produced as default) will not be readable
117 by older releases.
118
119 ;general
120
121 * fixed a few small bugs which could cause the display to crash in ganymed
122 and sponde
123
124 * in sequence file the date can now be omittet. In this case the
125 leading date with the underscore is missing in the expected filename
126
127 * the geometry class now also supports other geometries than just hexagons
128
129 ;automation
130
131 * added magnetic field Azimuth direction (ARRANG), currently
132 at ~ -7deg at La Palma
133
134 ;database
135
136 * plotdb.php: added default (sequences) for startup, added possibility
137 to set size of plot
138
139 * added a new table ''RunDataCheck'' which containes the rates after
140 image cleaning for every run which succeeded star. It can be
141 plotted using ''plotrundb.C''
142
143 ;merpp
144
145 * added support for Arehucas Version >= 200812140
146
147 * added support for Arehucas Version >= 200809030
148
149 ;mars
150
151 * The display now also displays the trigger pattern
152
153 * The display can now display ceres reflector (_R_) files
154
155 ;ceres
156
157 * added a uniformly distributed one-bin time jitter for the start of the
158 digitization. Otherwise the first photon would be digitized always with
159 the same alignment to the bins
160
161 * Added a plot showing the production height of the photons
162
163 * Moved the particle id from the event header to the run header
164
165 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
166
167 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
168
169 * Added many new options to control the tasks. For deatils see ''ceres.rc''
170
171 * Removed obsolete plots in pedestal and calibration mode
172
173 * Removed the non-NightSky photons from the plots where they are just
174 disturbing
175
176 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
177
178 * The daq event number now represents the readout number
179
180 * The camera ''electronics'' can now be ''switched off''
181
182 * A new tab ''Info'' now display basic things like the reflector
183 layout
184
185 * Improved reading speed for corsika files
186
187 * Improved memory handling (if a large ampount of memory was needed
188 for a single event all further events were stored in the same
189 memory and it was never freed, so the program took this memory
190 until the end)
191
192 * Converted the code from MMCS' reflector program to MSimAtmosphere
193 (instead of the tables build in for MAGIC Winter and Summer
194 atmosphere we use the values written by Corsika fitted to the
195 tabulated atmosphere given as input)
196
197 * For caluclating the displayed image parameters in ceres a basic
198 image cleaning removing isolated pixels is now done.
199
200 * The magnetic field direction (ARRANG) is now taken into account
201
202 * Added plot for the energy threshold after trigger ''Threshold''
203
204 * Added plot for the effective collection area after trigger ''TrigArea''
205
206 ;star
207
208 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
209
210 * The definition of fConcCore has slightly changed. The numbers
211 might decrease a little bit (the effect should be rather small)
212
213 ;ganymed
214
215 * added pointing model 328198
216
217 ;sponde
218
219 * The SrcPos plot for your MCs was so far meaningless because it just
220 displayes the MSrcPosCam data from the input star-files. Unfortunately,
221 this containes was never written to the star-files yet.
222
223 * A new Tab 'OnTime' is available which is an effective on-time
224 fit as in star but for all data. This is mainly for manual cross-check
225 of the effective on-time
226
227 * In some circumstances it might be necessary to re-calculate the
228 eff. on-time from the fit in the new tab, e.g. when a zenith distance
229 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
230
231 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
232 it to its own output file (for convinience)
233
234
235
236== Version 2.2 (2009/01/30) ==
237
238 ;SUGGESTION
239
240 * This release doesn't contain a major change which is expected to
241 change your results. Nevertheless there are small changes to
242 the calibration which can effect at least the first few hundred
243 events in any (mainly MUX and even more SUM) sequence a little bit.
244 So it is recommended although not necessary to reset your sequences
245 in the database before further processing.
246
247 ;NEW
248
249 * A first implementation of a Monte Carlo simulation program
250 (ceres - Camera Electronics and REflector Simulation) has been
251 implemented. It can simulate a full telescope already including
252 a complete reflector simulation and a flexible trigger and readout
253 simulation. Currently, no perfect setup is implemented and
254 especially the output of the program (data structure) should
255 be considered alpha state. Also the user interface is not yet
256 ready.
257
258 ;general
259
260 * All command line options after -- are now interpreted as
261 arguments (usually everything which doesn't start with a minus)
262 rather than options (usually everything which starts with a
263 minus). This allows to use file names starting with a -
264
265 * In all resource files you can now initialize the random number
266 generator. For details see: MJob::InitRandomNumberGenerator
267
268 * added a new program called ''readcorsika''. It's purpose is (in analogy
269 to readraw and readdaq) to read a Corsika output file (for now
270 only cherenkov output is supported) and print its contents in a
271 human readable form. It can also write the contents of this file
272 into a root-file.
273
274 * The calculation of the maximum distance to the origin in a MGeomCam
275 has been improved (edges might be further away than the sides).
276 This is just a tiny change but it might change the appearance of
277 the radial profiles a little bit.
278
279 * The default binning of the center-of-gravity plot has slightly been
280 increased
281
282 ;Database
283
284 * Added informations about the DC currents (fMinCurrents, fMedCurrents
285 and fMaxCurrents). The values are retrieved from the plots showing
286 the average DC currents of all pixels versus time.
287
288 * Websites with tables have now the opportunity to remove lines
289 ('-' button at beginning of each line) and get all lines back
290 ('+' at top of the column)
291
292 * Websites: added option to query only sequences containing sumtrigger
293 events
294
295 * Websites: added option to group by date (year, month, night) for runs
296 and sequences and enabled that combining of different group-bys,
297 e.g. status, date and source is possible
298
299 ;automatic analyis
300
301 * Rewritten producing plots in the web.
302 New plots, namely the output of plotoptical.C (extinction curve from
303 KVA), plotstat.C (status of the automatic analysis (percentage of
304 processed, analysed data etc.)) and plotusage.C (statistics of the
305 condor usage in the data center) has been are available now next to the
306 plots of plotdb.C
307 Mean values from the plots (output of the macro) are provided in a
308 txt file now.
309 The creation of the plots for callisto, star and ganymed in the web is
310 now steered via database. Consequently the plots are faster and
311 reliable up-to-date.
312 For all plots, a new layout is available facilitating the browsing
313 through the plots and providing additional information on the
314 displayed values. (tabs.php) These plots are linked from the DB
315 websites and the wiki.
316
317 ;statusdisplay
318
319 * The ''Loop'' entry in the menu bar now contains an option to pause
320 the loop and to process single events.
321
322 ;merpp
323
324 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
325 instead of RunHeaders)
326
327 * Now allows to merpp files newer than 2008/09/03.
328
329 * Added fixes for wrong (wrong or double) run- and file-numbers
330 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
331
332 ;callisto
333
334 * Extracting the pulse position for the pulse position check events
335 with sum trigger were denied. This decreased the statistics
336 extremely and therefor the resulting puse position was calculated
337 quite weak. Now sum events pass the calculation if and only if they
338 have also a level 1 trigger.
339
340 * the extraction of pedestal events and pulse position from the
341 first data events is now more automatic and makes sure that
342 a more precise number of events is extracted independent of
343 the ratio with which pedestal events or events with signals
344 are contained in the data.
345
346 * Updated Muon calibration constants for all MUX data (teh changes were
347 all smaller than 5%)
348
349 ;star
350
351 * For the calculation of the effective on time all sum-triggered events
352 were skipped. Now all Level1-triggeres events will pass. This might
353 result in a slight inaccuracy of the effective on time.
354
355 ;ganymed
356
357 * If the source position is more than 1deg away from the camera
358 center an error is raised now.
359
360 * Hopefully fixed the bug ''ganymed crashes when resized''
361
362 ;sponde
363
364 * Fixed a problem which causes the fitted spectral slope to be displayed
365 incorrectly. If you use MJSpectrum::FormFlux in your macros make
366 sure that the parameter 0 of your fit is negative.
367
368 * Added a histogram showing the read source position of your MCs
369
370
371
372== Version 2.1.1 (2008/08/04) ==
373
374 ;Database
375
376 * Added the median number of photo electrons from the calibration
377 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
378 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
379
380 * Added fTotOnTime, which is the on-time as given by the run-headers
381 (in contradiction to fAbsOnTime which comes from CC)
382
383 * Added new primaries for the new data structure (Magic II): for the
384 tables dealing with sequences (SequenceBuild Status, Sequences,
385 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
386 this is the telescope number (fTelescopeNumber) for the tables dealing
387 with runs (RunData and RunProcessStatus) this is in addition the file
388 number (fFileNumber)
389
390 * Added column fPriority to the status tables to be able to steer the order
391 in which the data is processed. As default the run, sequence and dataset
392 number are used.
393
394 ;automatic analyis
395
396 * Adapted scripts to the new data structure: They can handle now different
397 telescopes (getting the information as usual from the database).
398 The paths for Magic 2 are not yet implemented.
399
400 ;general
401
402 * should work now with root 5.20/00 (please note that root 5.20/00
403 we encounter crahses in the status display which are ot yet
404 understood)
405
406 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
407 instead of the base name of the file. This makes them easier to
408 access from the code
409
410 * Default Monte Carlo names in MSequence do not require the _E at
411 the end anymore
412
413 * where abrrevating a sequence file with a sequence number is possible
414 also "telescope:sequence" is now accepted, e.g.:
415 star 2:2000123 --out=output
416 see the programs' help for more details.
417
418 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
419 from the database. See the constructors for more details.
420
421 * MReadTree now supports friends
422
423 * MReadTree can now read also files not written by MARS and store
424 the data encapsulated in emulated MParContainers
425
426 * added a new starguider calibration valid since 15.1.08
427
428 ;showplot
429
430 * showplot can now read more than one file at once. This is especially
431 inetersting if reading files containing pure canvases
432
433 ;merpp
434
435 * we merpp the dc currents now also from the camera reports (they have
436 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
437
438 * In the automatic analysis we omit merpping of the currents from the
439 caco files and use the lower rate camera reports from the cc files
440 instead
441
442 * merpp has been redisigned to allow merpping of the cc-reports
443 of a whole sequence. This allows to design a very simple analysis:
444 mkdir output
445 ./callisto 100776 --out=output
446 ./merpp 100776 output
447 ./star 100776 --ind=output --out=output
448 Instead of the sequence number also sequence files are accepted.
449
450 * Implemented a fix for run-numbers between 1001348 and 1001396
451 which were incorrectly assigned by the cc.
452
453
454 ;callisto
455
456 * added a filter again which was was removed in the last release.
457 it removed the most brightest events. This should not change
458 any analysis result because these events are so bright that
459 they cannot be analysed anyway, but the bad-pixel plots doesn't
460 show outliers.
461
462 * updated muon calibration constants for the periods 51-57,
463 58-63 and 67-
464
465 ;star
466
467 * The camera currents are now displayed with the rate of the camera
468 reports instead of the caco reports
469
470 ;ganymed
471
472 * if mc camera files are new enough (>=8) the source position in the
473 camera is now calculated from the stored telscope and shower
474 orientation (Note, that this might not be suitable in all cases
475 depending on the aim of the study. These case still needs
476 implementation)
477
478
479
480== Version 2.1 (2008/06/18) ==
481
482 ;Database
483
484 * introduced average temperature and wind speed from star-files
485
486 * introduced average values from Pyrometer (mainly Cloudiness)
487
488 * introduced the ratio of accepted calibration events in the
489 calibration run
490
491 * introduced the average rates of the different trigger pattern,
492 e.g. the rate of pedestal and calibration events, from the signal-file
493
494 ;general
495
496 * fixed GroupBy options in plot*.C macros
497
498 * only display KVA points (not the Tuorla points) in plotoptical.C
499
500 * all programs now allow to add resources to the ones from the resource
501 file or overwrite them from the command line. This can be done like this
502 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
503 if something seems to be wrong you can debug what the program is doing
504 using the option --debug-env=3
505
506 * increased the diversity of debug levels. That also means that with -v3
507 you get now less output, i.e. only the output which is important for
508 an analysis. To get more output which helps for debugging try 4, 5 and 6.
509
510 * fixed a problem in the task synchronizing the reading of the reports
511 and the data stream. The effect was that in some circumstances the last
512 events of some trees could have been skipped. Since this is only a
513 very tiny part of the data no severe effect to your analysis results
514 is expected (an exception might be very short, i.e. singel runs,
515 datasets).
516
517 * Dataset file now allow to include the sequence file directly within
518 the dataset file and also allow to exclude single runs from the dataset.
519 (for more details see Class reference of MDataSet)
520
521 * Sequence files now allow for excluding runs from the analysis
522 (for more details see Class reference of MSequence)
523
524 * added code to process the sum-trigger flag
525
526 * the histogram classes MH3 and MHn now support profile histograms
527
528 * the histogram classes MH3 and MHn now support labels at the axis
529
530 * the Random Forest Train-classes (MJTRain*) now store the used datasets
531 in the output file
532
533 * the MFMagicCuts have a new option to allow a linear area cut (for
534 special studies)
535
536 * The liniking of the shared object is now done into a file defined
537 by 'mktemp'. This should be a local file system which accelerates
538 liniking a lot.
539
540 * The code has been prepared for compilation with root 5.18/00d
541
542 * The MHEnergyEst histogram now shows the distribution of
543 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
544 and (Eest-Emc)/Emc vs Emc.
545
546 * fixed mars (event display) for merpped raw-data and MC data
547
548 * adapted the synatx of sequence files to allow for the new run/file
549 scheme. For more details see class description of MSequence
550
551 ;showplot
552
553 * Added support for tiff files
554
555 * Added support for csv files (tables containing tab number,
556 name and title)
557
558 * Tabs now can have a title which is displayed in the postscript file
559
560 * When multiple file are written at once (e.g. pngs from a display)
561 it is now possible to use the tab name and or tab number in the
562 file name. For details see showplos's help.
563
564 ;merpp
565
566 * Implemented cc file version 2008-02-20/0
567
568 * Implemented cc file version 2008-05-19/0
569
570 * With new options merpping can be restricted (in addition to the
571 run-number) also by telescope and file number.
572 For details see "merpp --help"
573
574 * Implemented raw data format 11 (the most important change, except
575 from plenty of changes in the format definition, is the addition
576 of the file-number in the header) If nobody makes a mistake this
577 format should have the advantage that it is by definition forward
578 compatible, so old programs will be able to read newer formats.
579
580 * Added Pyrometer information to default output (stored in a new Tree
581 Pyrometer, needs a complete new merpp, i.e. new calibration)
582
583 * Merpping (also update) can now be restricted to one single report.
584 For example:
585 If you want to update an old file with Pyrometer information call
586 merpp --only=Pyrometer --update
587
588 ;callisto
589
590 * in the pedestal processing now at least 50 processed events are
591 required for succeeding.
592
593 * the signal and calib files now contain also the sequence information
594
595 * the two MPedestalCam in the calib file now have proper names
596 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
597
598 * Both pedestal cams now contain the number of events processed
599
600 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
601 i.e. for the extraction of the calibration pulses basically the average
602 over all events of the first slice instead of all slices was used.
603 Since pedestal and calibration constants are continously recalculated
604 this only effected the very first events of every sequence.
605
606 * For the extraction of the position of the maximum sample now the
607 extraction range is set automatically to the extraction window,
608 before the whole accessible range was used.
609
610 * If the number of samples in the events and the number of samples
611 in the run-header disagrees now an error is raised (this can
612 happen in not well simulated Monte Carlo files)
613
614 * In the case of MUX-data pedestal events with the lvl1 trigger flag
615 could survive into the pedestal calculation -- fixed.
616
617 * Tab "TrigPat" added showing the distribution of the trigger pattern
618 as found in the run-files (normalized with the run length)
619
620 * The selection of events from the trigger pattern has been improved.
621 If the trigger pattern is corrupted events won't pass anymore.
622
623 * Added a new command line option --dev-null to suppress output of
624 Y-files (this is useful for test cases)
625
626 * added a new tab "CalPos" showing the arrival time of extracted
627 interleaved calibration events
628
629 ;star
630
631 * the star file now contains also the sequence information
632
633 * Added a new command line option --dev-null to suppress output of
634 I-files (this is useful for test cases)
635
636 * Tab "Rate" added showing the distribution of the trigger pattern
637 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
638 the Y-files (normalized with the run length)
639
640 * The effective on-time calculation doesn't use events with only
641 sum-trigger anymore
642
643 * The data in the MHWeather tab has been reorganized. The never
644 working solar radiation has been removed and the data from
645 the pyrometer (cloudiness, air and sky temperature) is
646 displayed in addition.
647
648 ;ganymed/sponde
649
650 * Now data points are even shown correctly if they have error bars larger
651 than one sigma. Points with null or negative significances are omitted.
652
653 * DrawNicePlot now allows to set a projection range
654
655 * Updates pointing models. One is applied after the implementation
656 of the new LUTS in August, the other one is applied after the
657 next major change of the pointing model in October. Note that
658 these models are preliminary and give wrong results below Zd=65deg
659
660 ;sponde
661
662 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
663
664 * a new option "--force-runtime" is available. In case of very short
665 datasets (for light-curves) which are in the order of a few
666 minutes the calculated effective on-time is not very acurate because
667 it is quantizised in the order of a minute. Therefore you can switch
668 to using the real run-time instead (remakrt: this ignores any
669 dead-time!)
670
671 * a more analytical way is used to "fill" Monte Carlos into regions
672 of impact parameters which have not been simulated because the
673 trigger efficiency is assumed to be 0.
674
675 * estimated sensitivity curves for hi and lo zenith angles are shown
676 scaled to the correct observation time and collection area
677
678 * the Monte Carlo events after cuts are now written to the output file
679 if an output file given
680
681
682
683 *** Version 2.0 (2007/09/03)
684
685 - database: the position used for the pulse pos check was missing
686 in the callisto output and could thus not be filled into the DB.
687 Also the old values seemed not exactly the PulsePos used for
688 teh check.
689
690 - general: Resource file now allow an Include-Resource, i.e. you can
691 read a resource file with default settings, include it in your
692 resource file and overwrite the settings in your file. More than
693 one include file is allowed. Inclusions can be iterative.
694 Include: mydefaults.rc yourdefaults.rc
695 The resources in the first file have higher priority than the
696 second file.
697
698 - general: Now the output files (calib*.root, etc) also contain the
699 resource file (to check it open it in the TBrowser and choose Print()
700 from the context menu)
701
702 - general: Dataset files now allow to overwrite the default path
703 to search for sequence and data files. Note, that the program
704 option and individual resources will overwrite it. For example:
705 SequencePath: /magic/montecarlo/sequences
706 DataPath: /magic/montecarlo/star
707
708 - general: Fixed a problem with variables in MDataPhrase. It seems
709 that only optimdisp (didn't work) was effected.
710
711 - general: Some improvements to the optim and train processing. For
712 example the ststud window now got a proper title.
713
714 - general: The "Status Display: " was removed from the window title
715 within an Eventloop.
716
717 - general: added a new flexible histogram-class (MHn) which can be used
718 for example in testing after optimizations or training to produce
719 user defined histograms.
720
721 - general: The Random Forest now allows attaching an evaluation
722 function which is applied to its output. This allows to train
723 on whatever you like (eg. train on log10(energy), but return
724 energy)
725
726 - general: The Random Forest training of energy (trainenergy.c) and
727 disp (traindisp.C) has been improved by more graphical output to
728 judge the result.
729
730 - general: The training of energy (trainenergy.C) has been improved
731 a lot by training on a different quantity than energy. It gives
732 a result which is highly independant of the source spectrum
733 and shows lower bias than all other options.
734
735 - general: Dataset files are allowed to contain collections of
736 datasets. For more details see the class reference of MDataSet.
737
738 - general: The default WobbleMode in a datset file now (if not
739 overwritten) is "auto", i.e. wobble mode is set if the dataset
740 doesn't contain off-sequences.
741
742 - merpp: Merpp can read file format version 9 now. Please realize
743 that for file format version 9 the extraction range is different
744 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
745 the first and last 15 slices have been removed from all MUX data.
746
747 - mars: Similar to writing movies you can now select events which
748 should be displayed in your display. Therefore add the following
749 lines to your mars.rc:
750 MFEvtNumber.FileName: ganymed00223552.root
751 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
752 The input file can be a ganymed-file after (ganymed*.root) or
753 before (ganymed*-summary.root) file. For example to select all events
754 from your on sample after cuts (excluding the ThetaSq cut) use
755 MFEvtNumber.Selector: DataType.fVal>0.5
756 To show all events from your on-sample after quality cuts
757 use the summary file instead.
758
759 - mars: new ways to call mars are implemented. Instead
760 of calling
761 mars filename.root
762 you can now also use
763 mars sequence.txt
764 or
765 mars sequence.txt inputpath
766 or replace sequence.txt by the sequence number if the default
767 sequence file should be used.
768
769 - mars: The default size has been increased
770
771 - mars: There are two new heckboxes which allow to switch off
772 the calculated image parameters
773
774 - callisto: was broken for MCs... fixed.
775
776 - callisto: improved calculation of spline coefficients a lot. This
777 leads to a further improvement of the event rate calibrating MUX
778 data of about 15% (175evt/s instead of 150evt/s)
779
780 - callisto: finally the raw data we read is now real 16bit (with
781 10bit precision) for MUX data and not a stripped 8bit number
782 anymore. Due to scaling of the numbers (without precision loss
783 into an [0-256[ range, the final numbers for pedestal, pedestalrms
784 and extacted signal don't change. However, at all places where
785 raw data is directly accessed (eg. saturation and variation
786 limits in the signal- and pedestal-extraction) the numbers
787 refer still to the data's 16bit range.
788
789 - callisto: The maximum arrival time difference used in the bad
790 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
791 for both, old FADC and MUX-FADC, data.
792
793 - callisto: Be aware that callisto is now calibrating the arrival time
794 in nanoseconds rather than time slices. Also all following tasks
795 have been changed to assume ns units now. If you star data
796 calibrated with an older version it might be necessary to adapt
797 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
798 to obtain optimal results. The plot in the PulsePos tab
799 will now be in ns, too. This might also mean that the Muon
800 analysis in star might not work as perfect as expected as long
801 as old files read in.
802
803 - callisto: The calibration constants of earlier updates got lost
804 somehow. All constants have been updated.
805
806 - star: The PSF is now determined from the profile of the ArcWidth
807 instead of arcwidth/radius. The old way gave to much weight
808 to the bins with low statistics. The reference lines have been
809 updated.
810
811 - star: For speed reasons events suitable for the muon analysis
812 are now also preselected by fConcCOG<0.1 which seems to be a very
813 good preselector for muons.
814
815 - star: is now calculating a new timing parameter the Slope along
816 the major and minor axis of the shower. Therefore a numerical
817 solution of a line-fit is used. To use MHillasExt.fSlopeLong
818 and MHillasExt.fSlopeTrans don't forget to multiply it with
819 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
820
821 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
822 have been removed from MNewImagePar. They have never been good for
823 anything.
824
825 - star: Implemented a new recursive algorithm which is supposed to be
826 faster. Also implemented new cleaning oiptions, which are:
827 + CleanLevel0:
828 The cleaning level above single core pixels can be kept
829 + KeepIsolatedPixels:
830 Define whether single core pixels should be kept
831 + TimeLevel1:
832 The coincidence window in nanoseconds to single used neighbors
833 + TimeLevel2:
834 The coincidence window in nanoseconds to two used neighbors
835 + PostCleanType:
836 MOde in which a time dependent post cleaning should be applied
837 0: No post cleaning
838 1: Require for each used pixels at least one used neighbor
839 within a time-window of CleanLevel1
840 2: Require for each used pixels at least two used neighbor
841 within a time-window of CleanLevel2
842 3: Require first two and second one used neighbor
843 within a time-window of CleanLevel1 and fCleanLevel2
844 respectively
845 + RecoverIsolatedPixels:
846 - recoveres isolated core pixels if they have a used neighbor
847
848 - mars/star: The new default cleaning is:
849 + CleanLevel1: 6.0
850 + CleanLevel2: 3.0
851 + CleanTime1: 1.75
852 + CleanTime2: 1.75
853 + PostCleanType: 3
854
855 - star/ganymed: The old spark-cuts have been replaced by new ones.
856 These new spark cuts have been cross checked with the sequences
857 84720 (before splitter), 101041 (after splitter) and 223539 (new
858 FADCs). In all cases they seperate pretty well, but of course not
859 perfect. Monte Carlos have suggested to tighten the cuts a little
860 bit further at low sizes. This has been done.
861
862 - ganymed: IMPORTANT - The spark cuts have been changed to match
863 all available data more or less well. This might mean that for
864 YOUR data there are still sparks visible.
865 Whenever you do an analysis you have to make sure that NO sparks
866 survive your cuts!
867
868 - ganymed: The old hadronness and size cuts have gotten new indices
869 (10, 11). The old indices 8 and 9 now mean an additional condition
870 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
871 If you want to switch off this cut just move the line far away enough,
872 e.g. by setting c[9] to -500. Please update your ganymed.rc files
873 accordingly!
874 The unit of c[9] is deg. It is the dist at which your cut will
875 cross the slope==0. The unit of the slope is ns/deg. So if
876 you readin files calibrated with an older Mars-version you
877 have to adapt the default value for c[9] to the FADCs:
878 - Multiply by two for the MUX FADCs (run number > 200.000)
879 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
880 - Multiply by 42 for the meaning of life (run number = 200.000)
881
882 - ganymed: The old Cut0 is now called CutQ and is calculated before
883 the source position is caluclated. If you need a quality cut
884 including source dependant data (be very carefull with this!)
885 you have to use Cut0 instead.
886
887 - ganymed: now properly supports three off regions in wobble mode.
888 It will be the default from now on in ganymed_wobble.rc. To change
889 the number of off-regions use
890 NumOffSourcePositions: 1
891 in your ganymed.rc. Also by default no off-theta cut will be done
892 anymore so that you will get a background level higher than the
893 signal level in your ThetaSq plot for ThetaSq>0.2.
894 Due to this be carefull changing the scaling mode away from
895 "None". You will underestimate your signal if your scale interval
896 is not properly set.
897 (Rem: ThetaSqN is no longer needed)
898
899 - ganymed: is now storing the events of all (on- and off-)
900 source positions even in the case of more than one off-source
901 position. This should allow sponde to work properly and the
902 energy estimation is done correctly in all cases (without any
903 "nearest position" trick)
904
905 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
906 with a real pointing model for the starguider is done, calibrated
907 with more than thousand tpoints taken from this date on.
908
909 - ganymed: was broken for Wobble-MCs... fixed.
910
911 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
912 has changed. Note that your old ganymed.rc will be incompatible
913 with the new algorithms! Please check the ganymed.rc files and
914 the class description of MFMagicCuts for more information.
915 It is recommended at the moment to use identical Disp-Parametrizations
916 for on/off- and wobble-mode. If cuts are optimized only
917 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
918 should be optimized. All other values should be kept as they are.
919 If you want to do an anylsis without timing a parameters, you can
920 switch off the timing cuts by seeting parameter 7 to a very small
921 value (eg. -99). To remove the slope parameter from the disp
922 paremtrization set parameter 8 to 0.
923
924 - ganymed: The distribution of observation time versus zenith
925 angle is now shown for off- AND on-data.
926
927 - ganymed: The contents of the source position plot are no longer
928 averaged, thus a lot of (fake) events between the two wobble
929 positions have disappeared.
930
931 - ganymed: There is a new tab "CutT" it contains the VsSize plots
932 with the CutT, whihc is defined in ganymed.rc, applied. It
933 is resonable to use your theta-cut for it, to see if there is
934 something strange (sparks!) in your signal-region.
935
936 - ganymed: To choose a dataset from a collection in a dataset file
937 use the new command line option "--dataset=12345"
938
939 - optim, sponde: should now properly support three off-regions.
940 Just produce your ganymed summary files with three off-regions.
941 optim and sponde will automatically get all off events from
942 all off-regions from this file. Please do not forget to
943 set the scaling in optimwobble.C properly:
944 fit.SetScaleUser(1./3);
945 it is not yet read in automatically (will follow soon).
946 In the case of fixed Scale you can also use
947 cuts.SetThetaCut(MFMagicCuts::kOn);
948 no off-cut needed.
949 Be carefull in case of three off-regions when switching on
950 scale mode. Make sure that the scale interval is set correctly.
951
952 - sponde: sponde.rc and sponde_onoff.rc are now idetical
953
954 - sponde: the resouce files have been rewritten with a lot of
955 comments and a well working parametrization for an energy estimator
956
957 - sponde: In the estimated energy versus monte carlo energy plot the
958 contents where exchanged.... fixed.
959
960 - sponde: the so called "accurate"-mode has been removed. It didn't
961 give any improvement in accuracy, only decreased execution speed.
962
963 - sponde: the so called "simple"-mode has been removed. It didn't
964 give any improvement in simple.
965
966 - sponde: the so called "refill"-mode has been removed. It was anyhow
967 not implemented.
968
969 - sponde: now checks whether the theta distribution of your on-data
970 and the theta-distribution of your Monte Carlo sample (after
971 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
972 sample is incomplete) execution is stopped. Execution can be forced
973 using the new option --force-theta. Use this option with care!
974
975 - sponde: Proper collection areas can now be constructed also from
976 Monte Carlo samples generated with different maximum impact
977 parameters. Note that in previous version you neither got
978 a warning or failure, nor was there any obvious sign that the
979 collection area was overestimated due to usage of files with
980 different maximum impact parameters.
981
982 - sponde: If MC files with different lower energy limits are used
983 the primary MC spectrum is artificially completed down to the
984 lowest energy used at all. WARNING: that this gives correct
985 collection areas ONLY if none of the events in this region would
986 survive your cuts at all.
987
988 - sponde: the output file now contains more information about
989 the spectrum (eg. the full 2D collection area histogram).
990 Note, that this information can only be written to the file
991 if it is stored automatically via command line argument.
992 If you only store the status display from within the display
993 the information is lost.
994
995 - sponde: added a new tab "Disp". It shows the residual of the disp
996 (Disp-Dist) versus several parameters and it is meant to judge the
997 quality of the disp estimator. In the ideal case the residual is zero
998 and doesn't depend on any variable. The tab is displayed after
999 CutQ and Cut0.
1000
1001 - sponde: added a new tab "Energy". It shows the residual of the
1002 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1003 several parameters and it is meant to judge the quality of the
1004 energy estimator. In the ideal case the residual is zero
1005 and doesn't depend on any variable. In reality even a good estimator
1006 can show residuals versus Monte Carlo energy. The tab is displayed
1007 after all cuts.
1008
1009 - sponde: added a new tab "EventDist" showing the unweighted real
1010 absolute number of events of your sample after cuts. This tells
1011 you how many events with this energy you had in your MC files.
1012 The same information you get from the error bars of the weighted
1013 histograms, but this is less intuitive.
1014
1015 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1016 for comparison. It is not meant to show these curves in
1017 publications, they are only for production.
1018
1019 - sponde: The OriginalMC tree with the events produced by corsika
1020 is now processed only once
1021
1022 - sponde: Finally fixed most annoying bug, which has effected the
1023 last bin of the collection area. It was the problem that binnings
1024 of root histograms are from 1 to n (included) but there was a C-like
1025 loop in sponde from 0 to n (excluded). Now the loop also includes
1026 correctly under- and overflow-bins. The worse thing with this is,
1027 that for the events in the highest bin not only the bin-content
1028 was wrong, but also the weights applied to these events, which could
1029 in pricipal effect also other parts of the distribution (eg. due
1030 to energy estimation). Fortunately it effected only a few events
1031 in most cases.
1032
1033
1034
1035 *** Version 1.2 (2007/05/14)
1036
1037 - database: The database now has two new values Unsuitable50 and
1038 Unsuitable01. They express the number of pixels which are
1039 unsuitable for more than 50%, respectively more than 1%, of
1040 all calibrated event. It is a more accurate number than the
1041 previously used numbers, because they only take the first
1042 calibration (ignoring the interleaved calibrations) into account.
1043
1044 - database: The database now has two other new values UnsuitableMax and
1045 DeadMax. They express the maximum number of pixels which were
1046 unsuitable, respectively dead, during the sequence. Because
1047 of high pedestal rms (cars passing) a few events with very high
1048 numbers of unsuitable pixels can happen. Not to suffer from this
1049 effect we don't take the highest 0.1% of the numbers into account.
1050
1051 - general: fixed a bug which caused callisto and star to stop working
1052 properly because the callisto output was currupted
1053
1054 - general: a script called scripts/makemovie has been added which
1055 simplified the process of producing several movies from a single
1056 sequence with different setup.
1057
1058 - callisto: Some more code cleanup. Started to remove old obsolete
1059 code from cvs.
1060
1061 - callisto: The extraction of the pedestal with the extractor was
1062 not random. It seems that extracting at one position is still biased
1063 (for example in the first or last slices we could still suffer from
1064 switching noise) Now it is completely random.
1065
1066 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1067 pedestal files) individual pixels could be skipped due to high
1068 variations. This was already the case for the pedestal extraction
1069 from the lo-gains since the beginning and properly handled
1070 there, but was introduced in the extraction from the pedestal files
1071 a while ago. To calculate the average value it was still divided
1072 by the number of events procesed not by the number of summands
1073 really summed. This let to a pedestal which was a tiny amount too
1074 small (for a few piels in the order of 0.1%). This led to an slightly
1075 positive offset of the randomly extracted pedestal for a few pixels.
1076 I doubt that this has a big effect on the result, because the effect
1077 on the individual numbers is quite small. Due to this it is suggested
1078 that you rerun your calibration to make sure you are without any
1079 avoidable bias.
1080
1081 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1082 the median rms of the absolute arrival time and expressed in significance
1083 levels. This replaces the old meaning of an abolute upper limit. An
1084 absolute upper limit doesn't make much sense, because in our data
1085 all arrival times are shifted at the same time (in fact it might be
1086 a shift of the artificial trigger w.r.t. to the light flash).
1087
1088 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1089 of the number of unsuitable pixels over the whole sequence. This
1090 is usefull mainly to judge if an intermediate calibration had
1091 problems.
1092
1093 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1094 of the number of dead pixels over the whole sequence. Dead pixels
1095 in this context are unmapped pixels, i.e. pixels which could not
1096 be interpolated, and thus are ignored in the further analysis.
1097
1098 - callisto: It is now possible to use the position of the maximum
1099 of the spline as arrival time instead of the leading edge even
1100 when using the integral for the signal. Therefor set the extraction
1101 type to kIntegralRel ("IntegralRelative") and the relative height
1102 ("HeightTm") to -1:
1103 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1104 MJPedestalC1.ExtractSignal.HeightTm: -1
1105
1106
1107
1108
1109 *** Version 1.1 (2007/04/27)
1110
1111 - general: The new class MGeomCamDwarf contains the camera geometry
1112 for our prefered Dwarf camera and can be used to create general
1113 geometries of roundish or hexagonal cameras.
1114
1115 - mars: The default cleaning is now abolute 8.5/4.0.
1116
1117 - mars: The resource file mars.rc now contains examples for MUX data
1118
1119 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1120 data containing only 10-bit information is still cooked down to
1121 8-bit, by cutting away the lowest 8-bit.
1122
1123 - merpp: When reading raw data the data is now stored in a single
1124 array. The lo-gain array is obsolete. The interface stays the same.
1125
1126 - callisto: To process the new MUX data use the resource file
1127 callisto_mux.rc
1128
1129 - callisto: The -root and -raw options to read merpped raw data have
1130 been removed
1131
1132 - callisto: If the -mc option is given the sequence-name can now be
1133 replaced by the MC sequence number
1134
1135 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1136 -mc option can now be omitted
1137
1138 - callisto: Started further simplification by removing obsolete
1139 dependancies on MCalibIntensity*Cams.
1140
1141 - callisto: removed unsused intensity calibration from MJCalibration
1142 for further simplification
1143
1144 - callisto: for simplification removed references to
1145 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1146 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1147 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1148 (this should at minimum change nothing at all, and at maximum
1149 improve thing if these containers where somewhere not handled
1150 properly)
1151
1152 - callisto: Added the option to write an event movie. Please use
1153 this option with care (huge files) but exessively to understand
1154 our events. For further documentation please refer to the
1155 IACT wiki
1156 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1157
1158 - callisto: Improved binning for the pulse position check histogram
1159
1160 - callisto: The code calculating the pulse position checknow takes
1161 the pedestal into account
1162
1163 - callisto: The arrival time is now stored with full precision this
1164 helps to get rid of artefacts in histograms. For the signal this
1165 is not necessray because it is displayed in log-scale anyhow
1166
1167 - callisto: Fixed a problem with internal exclusions. Pixels which
1168 have once been marked as unsuitable didn't get the necessary
1169 histograms filled anymore to be rechecked with each interleaved
1170 calibration.
1171
1172 - callisto: The relative arrival time resolution (the rms of the
1173 relative arrival time offset) is now checked against its
1174 median and the median deviation, instead of the average
1175 plus an absolute offset.
1176
1177 - callisto: The relative arrival time offset is now calculated
1178 w.r.t. its median not w.r.t. to an artificial reference pixel.
1179
1180 - callisto: The relative time calibration now marks pixels with
1181 outlaying offset as unsuitable
1182
1183 - callisto: The interleaved relative time calibration has been switched
1184 on. The advantage is that pixels which are marked as outliers
1185 now can recover. An improvement over time is not expected, because
1186 the relative time calibration seems stable.
1187
1188 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1189 option can now be omitted.
1190
1191 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1192 or the option "-mc" is specified as default the monte carlo datacenter
1193 paths (/magic/montecarlo/...) are used if not overwritten in the
1194 dataset file.
1195
1196 - ganymed: The output files now contain run- and event-number for all
1197 events, accessible as RunNumber.fVal and EvtNumber.fVal
1198
1199 - ganymed: Added a plot showing the source position in the camera also
1200 for wobble mode
1201
1202 - ganymed: In addition to the existing task which can be setup to
1203 be executed after Cut1 a final task called "EstimateEnergy"
1204 has been added, executed before writing the final output
1205 (ganymed00000000.root). The task setup in all three cases
1206 can be choosen individually. (For all three(!) cases you
1207 can for example choose MRanForestCalc. For examples see all
1208 sponde*.rc and all ganymed*rc)
1209
1210 - ganymed: If a container "MEstimatedEnergy" is found in the
1211 parameter list (eg. because it was setup by MEstimateEnergy)
1212 it will be written to the output file.
1213
1214
1215
1216 *** Version 1.0 (2007/02/16)
1217
1218 - database: Website to plot values from the database has been added.
1219
1220 - database: The rate of spark events as found by star is now kept
1221 and the rate after cleaning is now with spark events subtracted
1222
1223 - general: The changes to the interpretation of phrases lead to
1224 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1225
1226 - general: Added example files how you can create your own calendar
1227 (eg. as christmas present) with Mars. Just run
1228 root macros/tutorials/calendar.C
1229
1230 - general: Added a possibility to display grouped data in the plotdb.C
1231 macro (and similar macros). This allows to plot hourly, nightly,
1232 weekly, monthly and yearly averages.
1233 For more details see the plotall function of the macro
1234
1235 - general: fixed the error display of the camera display. It showed
1236 wrong results.
1237
1238 - general: fixed a memory leak when reading many MStatusDisplays
1239
1240 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1241 between a spherical and a parabolic mirror
1242
1243 - callisto: We have a new pulse position check which takes the properties
1244 of the extractor automatically into account. So no need to set
1245 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1246 left is done. If possible the lo-gain extraction start and hi-gain
1247 extraction end is changed accordingly. If no proper extraction range
1248 can be set (hi-gain too much to the left) an error is raised.
1249
1250 - callisto: New swapped pixels have been found and corrected
1251
1252 - callisto: Redone the signal extraction this includes:
1253 + Unified the algorithms to extract the pedestal for all pedestal
1254 extractions done
1255 + Unification of hi- and lo-gain into one array
1256 + Unification of hi- and lo-gain extraction for Spline and
1257 Digital Filter (means now exactly the same algorithm is used,
1258 not a copy-and-pasted one)
1259 + Store pedestal subtracted data in a common place
1260 + Improved extraction algorithms. If the algorithms search a
1261 maximum but don't find one they don't return the maximum anymore
1262 + Improved the extraction such that a information for signal
1263 and time which is consistent is returned
1264 + replaced the numerical spline with a (not slower) analytical
1265 solution
1266 + Lowered the saturation limit from 250 to 245 to make sure that
1267 we are far away in all pixels from problems with the clock-noise
1268 + The start of the lo-gain extraction is calculated from the hi-gain
1269 arrival time. In case of saturation an estimation is used.
1270 + the hi-gain window was extended to slice 16. This allows extraction
1271 of very late pulses in single pixels or of huge hadron showers.
1272 + Now uses the lo-gain extraction range for pedestal extraction,
1273 not the hi-gain range in the lo-gain
1274
1275 - callisto: New hi-/lo-gain calibration constants have been produced
1276 for all periods from the statistic of the whole period. They are
1277 now used automatically depending on the periods. The old constants
1278 where deviation in avarega about 2%-3%. The constants are very
1279 stable from period to period (<<1%) except for exchanged channels.
1280 In a few cases the constants used so far were off by 1%-2% (maybe
1281 temperature effects?)
1282
1283 - callisto: To gain obsolete space we do not write the
1284 MPedestalFundamental anymore. Also calibration and bad pixel
1285 treatment is not done for it anymore because it has never been used.
1286
1287 - callisto: Fixed a bug in the seuqence handling which caused the
1288 light condition to be ignored
1289
1290 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1291 basically the same as "Cleaned" but the distribution devided into
1292 the events fullfilling a spark cut or being rejected by it.
1293 This cut can be changed from star.rc (see example inside) by
1294 the "SparkCut" directive
1295
1296 - star: Star displays now the average individual pixel-rate (IPR) versus
1297 time and the average discriminator threshold (DT) of all pixels.
1298
1299 - optim: fixed a problem with the optim-macros which was due to a bug
1300 in the new phrase parsing
1301
1302 - ganymed: To get a nice FalseSource plot (instead of the all-information
1303 debug plot displayed as a standard plot) use the context menu
1304 somewhere between the two upper plots, click on "DrawNicePlot"
1305 and enjoy the result. (It is the same context menu which contains
1306 the other options)
1307 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1308
1309 - ganymed/optim/train: The cut program, trainings- and optimization
1310 macros could run with less files found than expected from the
1311 sequence-files. No the execution is stopped in this case.
1312
1313 - ganymed: now stores the dataset in the output file with all information
1314 contained (as sequence number, sequence path, data path) so that the
1315 used dataset file can be recreated complete from the output
1316
1317 - sponde: now also allows the uasge of random forest
1318
1319 - sponde: added a plot showing the cut efficiency
1320
1321 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1322 errors (eg. effecting the collection area) because the errors of the
1323 two histograms were swapped in the calculation, which makes a difference
1324 in the case the histograms contains weighted events. Aditionally the
1325 totalarea was incorrectly taken into account, which results in too small
1326 errors, which makes a difference at low statistics were the errors
1327 or the collection area dominate.
1328
1329
1330
1331 *** Version 0.10.3 (2006/10/23)
1332
1333 - database: Implemented ObservationMode flag in websites.
1334
1335 - database: For sequences there is now also the stoptime available on the
1336 websites.
1337
1338 - database: Removed ManuallyChanged flag from sequence-info websites,
1339 as it is not needed anymore with the new sequence building algorithm.
1340
1341 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1342 Class for calculation of confidence intervals (upper limits).
1343 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1344 Please read the class instruction of TRolke for more information.
1345
1346 - general: The programs now return 0xfe if the requested resource file
1347 doesn't exist.
1348
1349 - general: Errors comming from root itself are now not output to
1350 stderr anymore but to our default (colored) log-stream.
1351
1352 - general: Changed the interface to TFormula such that now everything
1353 is parsed by TFormula, which should allow to use phrases even
1354 without paranthesis correctly parsed.
1355
1356 - callisto: replaced the AdHoc number of effective integration slices
1357 in the digital filter by an average of the correct number, averaged
1358 over all possible set of weights. This also gives correct numbers
1359 for the lo-gains which were totally wrong before.
1360
1361 - callisto: drastically reduced memory consumption by not storing
1362 all intermediate calibration results in memory anymore (we might
1363 write them into a file in the future)
1364
1365 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1366 debug plot displayed as a standard plot) use the context menu
1367 somewhere between the two upper plots, click on "DrawNicePlot"
1368 and enjoy the result. (It is the same context menu which contains
1369 the "DrawAll" option)
1370 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1371
1372
1373
1374 *** Version 0.10.2 (2006/10/15)
1375
1376 - general: changed the building of the sequence files such, that
1377 the source-/project name in case of wobble-sources is not the
1378 source/project of the first data run anymore but the new generalized
1379 wobble source/project
1380
1381 - general: Added some functions to MAstro to calculate sun and
1382 moon properties
1383
1384 - general: Added two new macros (starvisday.C and starvisyear.C)
1385 which allow to plot the visibility of several stars in one day
1386 or of one star along one year
1387
1388
1389
1390 *** Version 0.10.1 (2006/10/11)
1391
1392 - general: HTML logging output was distorted... fixed.
1393
1394 - general: Changed the writing of the sequencefiles such that only
1395 as many pedestal files as giving at least 1000 pedestal events which
1396 are nearby the first calibration run are used as pedestal runs
1397
1398 - sponde: In the calculation of the collection area(s) and the
1399 distribution for MOnte Carlo and estimated energy the error
1400 calculation was wrong because root didn't take the errors
1401 properly into account... fixed.
1402
1403
1404
1405 *** Version 0.10 (2006/10/10)
1406
1407 - general: all executables now check consistency of the root version
1408 installed with the root version used for compilation. The return
1409 code in this case is 255.
1410
1411 - general: The algorithm to build seqeunces has been redesigned
1412 completly. It is now more flexible in terms of a resource file
1413 resources/sequences.rc which can be used to partly overwrite
1414 the default algorithm and defined the important part of the
1415 algorithm. It also takes correctly into account several ways
1416 of taking wobble-data. Currently the new algorithm doesn't take
1417 the number of pedestal events anymore into account (so a sequence
1418 could have much less than 1000 pedestal events and data runs are
1419 no-more used instead)
1420
1421 - general: a lot of small changes to make the code compatible with
1422 root 5.12/00 and gcc 4.1
1423
1424 - general: Fixed some warnings thrown if more warnings are switched
1425 on in the compiler
1426
1427 - general: Added a function to MMath which returns the Median of
1428 the distribution abs(y[i]-median) but at 68:32 division instead
1429 of 50:50, which is somehow the median counterpart of the rms.
1430
1431 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1432 even if they are compressed with gzip (recommended compression
1433 is with "-1")
1434
1435 - showplot:
1436 + batch mode creation of image files now works with root 5.12/00
1437 + added support for writing bmp (though it never produces
1438 bmp which can be read by programs like xv or gimp)
1439 + added support for xml
1440 + added new option to start the display with a different size, by
1441 --display-width=nnn or --display-height=nnn
1442 + added options to define the canvas size when the display is started
1443 --canvas-width=nnn or --canvas-height=nnn
1444 the option can also be used for batch-mode conversion
1445 + added an option which automatically fits the display size to the
1446 desktop-size: --auto-size
1447
1448 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1449
1450 - merpp: allow the reports to have 1000ms due to a bug in the camera
1451 program.
1452
1453 - callisto: New swapped pixels have been found and corrected. For
1454 details see MRawRunHeader::FixAssignment()
1455
1456 - callisto: Callisto now raises an error if one of the input files could
1457 not be opened.
1458
1459 - callisto: In some rare cases it could happen that in the signal
1460 extraction of the digital filter the extractor returned nonsense
1461 results due a wrong initializion of a variable (this happens in
1462 cases in which the extracted signal is exactly zero or the
1463 digital filter couldn't slide because of a too small extraction
1464 window, which could happen in the lo-gain extraction)
1465
1466 - callisto: The lo-gains have been marked as valid in some cases
1467 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1468 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1469 smaller than the number of slices (fLoGainWindowSize) needed
1470 by the lo-gain extractor
1471
1472 - callisto: Updated absolute calibration constants (muon calibration)
1473
1474 - callisto: fixed a bug which caused the hi-gain saturation not
1475 to be handled properly in the spline (the position of the
1476 saturation was calculated incorrectly)
1477
1478 - callisto: fixed a bug which gave weird results if hi- _and_
1479 lo-gain could not be extracted properly. In some cases hi-
1480 and lo-gain have not been extracted at all and the random result
1481 got calibrated. In other cases the hi-gain was saturating and the
1482 lo-gain has not been extracted. For this a completly arbitraty
1483 scale factor was applied to the result from extracting the
1484 charge of the saturating hi-gain.
1485
1486 - callisto: improves handling of extracted signal if lo- and/or
1487 hi-gain could not be extracted properly. If no appropriate
1488 calibration of either the signal or the arrival time is possible
1489 the pixel is now markes as unsuitable instead of estimated.
1490
1491 - callisto: Fixed a problem in the spline extraction which gave
1492 weird results if the signal was extracted from the first (and
1493 highest) slice (as a workaround extraction from the first
1494 slice has been forbidden)
1495
1496 - callisto: Fixed a bug regarding the use of the QE which doesn't
1497 effect the result because the default is used anyhow.
1498 (The bug was there since 14/07/2005)
1499
1500 - callisto: Changed the default for fgLoGainStartShift to -2.4
1501
1502 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1503 factors to be always 10 for all pixels as soon as the first
1504 calibration update has happend.
1505
1506 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1507 was off by more than one slice (which gives wrong values for
1508 pixels which have saturated the hi-gain) This was a problem
1509 mainly for timing studies, not so much for the automatic standard
1510 analysis. Also the values for the Spline have been changed slightly:
1511 + Digital Filter from 1.70 to 0.95
1512 + Spline from 1.39 to 1.30
1513 The numbers were sorted out by an extensive test in the
1514 test-database.
1515
1516 - callisto: Removed the tab showing the average calibrated arrival
1517 time. It never gave useful information.
1518
1519 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1520 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1521 and both were extracted because the hi-gain was above the
1522 LoGainSwitch.
1523
1524 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1525 lo-gain pulse position (after application of LoGainOffset, which
1526 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1527 have saturated and both were extracted because the hi-gain was above
1528 the LoGainSwitch.
1529
1530 - callisto: After extensive tests a new threshold level for determination
1531 of the pulse position has been found at 50phe. This is due to the
1532 fact that for lower pulses the arrival time changes its average
1533 behaviour dramatically. It tends to the average of the extraction
1534 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1535
1536 - callisto: Added two more plots to the calibration part. The average
1537 extracted signal and the average extracted arrival time as
1538 extracted by the signal extractor (This can help debugging problems
1539 because it doesn't involve a fit)
1540
1541 - star: changed the fit for the effective on time such that initial
1542 values are calculated automatically now instead of using build
1543 in values. This makes the fit more indepedant of the underlaying
1544 rates. With a test of ~350 sequences in the test database it could
1545 be shown that the new fit gives the same result +/-1sek.
1546 The highest deviation was +5s the lowest -10s. You can now control
1547 the bahaviour with two resource values:
1548 MHEffectiveOnTime.FistBin: 3
1549 MHEffectiveOnTime.NumEvents: 12000
1550 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1551 from the resulting gamma candidates
1552
1553 - star: The Center histogram in MHHillas is now by default displayed
1554 with the colz draw-option
1555
1556 - ganymed: now produces valid error codes if failed
1557
1558 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1559 with the option "hadronness" instead of "area" or "both" if
1560 you want to use both cuts. The hadronness cut includes a fixed
1561 cut in hadronness (index 8) and a fixed cut in size (index 9).
1562
1563 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1564 the M3Long of the anti source to be not properly evaluated
1565 (actually is was evaluated as a unique random number) in case
1566 of optimization with anti-theta cut switched on. This might have
1567 lead to improper, but not necessarily wrong, optimization results.
1568
1569 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1570 how to use random forest
1571
1572 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1573 ganymed_onoff.rc. Seems to be unintentional that they were different.
1574
1575 - sponde: Since the introduction of the possibility to define a
1576 normalization energy instead of using the integral the default
1577 was not using the integral anymore but a normalization energy of
1578 1GeV. It is now the integral again.
1579
1580 - sponde: Fixed a problem in the weighting which did not allow
1581 a MC slope of -1.
1582
1583
1584
1585 *** Version 0.9.6 (2006/05/24)
1586
1587 - general: changed the binning of the azimuthal profile of the camera
1588 such that it is aligned with the 60deg boundaries.
1589
1590 - merpp: better handling of problems with the TH, TD part of the
1591 CC-REPORT for files older than 200507190 and 200412210
1592 respectively
1593
1594 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1595
1596 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1597
1598 - callisto: if an arrival time is extracted outside the fadc range is
1599 was set to the boundary before. Now a random number is assigned
1600 instead to avoid unfortunate coincidences of arrival times just
1601 by this arbitrary value.
1602
1603 - callisto: added a new option to callisto.rc which allows
1604 to set the maximum arrival time difference allowed for the
1605 badpixel algorithm to determin whether a pixels belongs to a shower:
1606 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1607
1608 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1609 to 0.9 as suggested by Stefan due to a recent study on the fraction
1610 of pixels surviving the image cleaning
1611
1612 - callisto: switched off error in case of "pulse is too much to the left"
1613
1614 - callisto: The extraction window is not adapted anymore. This means that
1615 the pulse is extracted from the full range. The draw-back is that the
1616 background (pedestal) will become slightly higher. Switching on/off
1617 the PulsePosCheck in the callisto.rc only effects filling the
1618 histograms.
1619 WARNING: If the pulse is too much to the left data is calibrated!
1620 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1621 in the database to make sure that your data is valid!
1622
1623 - star: Show also the number of stars correlated correctly by the
1624 starguider
1625
1626 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1627 than one off-source region in wobble-mode. To use it add the following to
1628 your ganymed_wobble.rc:
1629 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1630 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1631 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1632 + Cut1.ThetaCut: None
1633 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1634
1635 - ganymed: in the case the latest report is older than a default (currently
1636 one minute) and the current report will be skip the starguider
1637 correction and calibration will be reset. The maximum age can be
1638 setup from ganymed.rc by (minutes):
1639 MPointingDevCalc.MaxAge: 1.5
1640
1641 - ganymed: A first implementation showing all size-bins for the theta-sq
1642 resp. alpha-plots in a single tab automatically
1643
1644
1645
1646 *** Version 0.9.5.1 (2006/05/05)
1647
1648 - general: Added a new option "zdiff" to the Makefile which runs
1649 "cvs diff" as "make diff" would do, but with compression
1650
1651 - general: accelerated MTFillMatrix (used for eample in all training
1652 and optimization macros) by skipping some obsolete calles in the
1653 eventloop the first and second loop could be accelerated by ~20%
1654
1655 - general: Added a missing feature in the MFilterList class which
1656 prevented MFEnergySlope from working correctly in trainenergy.C
1657
1658 - general: Accelerated the random forest training and usage a bit
1659
1660 - merpp: Adapted to new raw data file format version 6
1661
1662 - merpp: fixed a problem with reading the starguider reports
1663 after 6.3.2006
1664
1665 - callisto: At some times six pixels had to be exchanged manually in the
1666 data. If the pixels to be swaped are both not found, an error was raised
1667 and calibration was stopped. Now it is assumed they are intentially not
1668 mapped and the Error has been changed to a Warning.
1669
1670 - star: Added new image cleaning based on the arrival time of the shower.
1671 The new cleaning can be accessed using the parameter "Time" instead of
1672 the the old one (like "Absolute) in the star.rc-file.
1673 Recommended parameters:
1674 + MImgCleanStd.CleanLevel1: 8.2
1675 + MImgCleanStd.CleanLevel2: 5
1676 + MImgCleanStd.CleanRings: 2
1677 + MImgCleanStd.KeepSinglePixels: No
1678
1679 - star: Simplified the calculation of the effective on time. By letting
1680 the fit start in the third bin the result should become more stable.
1681 The fit quality is now ignored for the theta-plot which is not used
1682 in the analysis later. Still better pre-cut which, for example,
1683 remove events triggered by car-light (rate changing on a short
1684 time-scale) are missing.
1685
1686 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1687 for optimization (kWeakSource) which is suggested by the Berlin
1688 people for weak sources.
1689
1690 - macros: plotdb.C:
1691 + if no dataset and no time-interval is given only sequences with
1692 an effective on-time above five minutes are plotted anymore
1693 + added a new tab "RelTime" displaying the relative on-time
1694 (effective on-time divided by the observation time)
1695
1696 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1697 the optimization became a lot faster
1698
1699 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1700 To display them just delete the pads displayed on top.
1701
1702 - ganymed: fixed a bug which could cause strange behaviour in wobble
1703 mode if no starguider information was available due to an incorrect
1704 initialization of the starguider calibration
1705
1706 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1707 be changed from within the plot. It can also be setup from the
1708 resource file using:
1709 + MHDisp.fScaleMin: 0.325
1710 + MHDisp.fScaleMax: 0.475
1711
1712 - ganymed, showplot: Fixed a problem with the fit to the off-data
1713 (HistOff) which could cause a time lag or an inifinite loop.
1714 The bug did not effect the results at all.
1715
1716 - sponde: Added a new tab showing the effective collection area after
1717 trigger (including the software trigger)
1718
1719 - sponde: MMcSpectrumWeight has a new option which allows to define
1720 the scaling factor not by the integral of the events but at
1721 a defined energy:
1722 e.g. MMcSpectrumWeight.NormEnergy: 200
1723
1724 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1725 eventloops the loop could be accelerated by ~20%
1726
1727
1728
1729 *** Version 0.9.5 (2006/03/13)
1730
1731 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1732 and added the standard Disp-parametrization
1733
1734 - macros: added a new macro datacenter/macros/plotstat.C allowing
1735 to plot statistics about the data processing
1736
1737 - macros: added a new macro to plot the muon correction coefficients
1738 versus period (macros/plot/mucal.C)
1739
1740 - showplot: path inflation for ganymed files was broken
1741
1742 - callisto: Fixed an important bug. When the number of saturating pixels
1743 were calculated the bad pixel information already available from the
1744 calibration was ignored. This yields wrong values in case pixels
1745 are broken and saturate all the time or randomly.
1746
1747 - callisto: Updated Muon calibration constants. Spline data now also uses
1748 different values for different periods
1749
1750 - star: The time-evolution shown in the effective on-time plot now displays
1751 the axis range (if there are no holes it should be similar to the
1752 effective on-time)
1753
1754 - star: Added two new image parameters:
1755 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1756 the three pixels next to the center of gravity and the size
1757 + MNewImagePar.fConcCore: The ratio of the signals of all
1758 pixels inside or touching the ellipse and the size
1759
1760 - ganymed: now stops in requested source isn't found in catalog file
1761
1762 - ganymed: Many improvements to the phi-plot in wobble mode:
1763 + with a template the ideal background is displayed
1764 + a possible camera inhomogeneity is taken into account
1765 + the anti theta cut is better supported
1766 + the phi cut is automatically calculated from the theta cut
1767 See the examples in ganymed_wobble.rc for more details.
1768
1769 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1770 times the bin-width instead of the absolute energy
1771
1772 - ganymed: New cuts for on/off and wobble mode
1773
1774 - ganymed: The smearing of the False Source plot has been increased
1775 to 0.06
1776
1777 - ganymed: The starguider calibration can now be changed from the
1778 resource file.
1779 See the examples in ganymed*.rc for more details.
1780
1781 - ganymed: added a new option for on-/off-observations
1782 MJCut.RandomSourcePosition
1783 If switched on the distribution of observation time of the source
1784 position in the camera is calculated from the on-data and randomly
1785 applied with this distrbution to the off-data.
1786
1787 - ganymed: by skipping some obsolete calles in the eventloop the
1788 first and second loop could be accelerated by ~20%
1789
1790 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1791 position in the off-data randomly according to its distribution in the
1792 on-data.
1793
1794
1795
1796 *** Version 0.9.4.3 (2006/02/13)
1797
1798 - general: Fixed a bug in most of the programs which prevented the
1799 compile date in the startup message to be displayed
1800
1801 - general: Simplified program calls. The following abbreviations
1802 are now possible:
1803 showlog callisto 55599
1804 showplot signal 55599
1805 star 55599
1806 callisto 55999
1807 ganymed 2
1808 In this cases the corrsponding root-, log-, sequence- or dataset-
1809 filename is automatically compiled using the default datacenter
1810 paths ("/magic/*")
1811
1812 - general: Fixed a long outstanding bug which made axis tick marks
1813 disappear if MDataFormula was used (eg. abs(x))
1814
1815 - general: Updated MMath with new functions to calculate the results of
1816 a exponential, logarithmic and powerlaw fits analytically.
1817
1818 - general: Updated some macros with comments:
1819 + macros/optim/optimdisp.C
1820 + macros/optim/optimenergy.C
1821 + macros/optim/optimwobble.C:
1822
1823 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1824 files) now allows adding a pre-cut like in the optimization. E.g. this
1825 is useful to perform g/h-separation cuts before training the random
1826 forest.
1827
1828 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1829 correctly assigned in the raw data assignement table. A fix to correct
1830 the assignment tabel have been implemented.
1831
1832 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1833 by 90, 180 and 270 deg.
1834
1835 - general: the macro plotdb.C now allows to highlight sequences belonging
1836 to a datset. For more details see the descritions in the macro.
1837
1838 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1839 of the display, it gave wrong results espacially for big sizes.
1840 Now the embedded canvas should always have a ratio width/height=3/2.
1841 The "Size" options have been updated with values fitting the 3/2
1842 size ratio.
1843
1844 - RanForest:
1845 + Updated the random forest classes to support also the
1846 regression method implemented by Thomas H.
1847 + added new tutorial macro how to train the random forest
1848 for energy estimation (macros/optim/rfenergyest.C)
1849 + new classes to train the random forest (still in development)
1850 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1851 + new tutorial macros for random forest training in macros/train
1852 trainenergy.C, traindisp.C, trainseparation.C
1853
1854 - mars: now allows to setup a cut in the resource file mars.rc to choose
1855 the events to be displayed, eg:
1856 Cut.Condition: {0} && {1}
1857 Cut.0: MHillas.fSize>100
1858 Cut.1: MHillas.fSize<900
1859
1860 - merpp: Made aware of the new .rep format 200510250. This includes
1861 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1862 the discriminator thresholds (MCameraTD) and the disciminator
1863 delays (MCameraTD). All of them come with the CC report and are therefor
1864 written to the CC tree.
1865
1866 - callisto: fixed a bug in the calculation of the arrival times in
1867 the Digital Filter. They were all shifted by the same amount
1868 fHiGainFirst. This caused an offset in the order of the position of
1869 the left border of the extraction window in the times calculated
1870 from high-gain and from low-gain. The bug effected only the absolute
1871 arrival times. The bug was there since 30.1.2005.
1872
1873 - callisto: Changed the ExtractionWindow for the pulse position check
1874 such that the camera inhomogeneity becomes as less as possible and
1875 comparable to the pulso position check switched off. More details
1876 on the study will be given at our result web-page.
1877
1878 - ganymed: ganymed.rc, ganymed_onoff.rc:
1879 changed to new cuts trained with 1ES1218 and Crab-data
1880 for maximum sigma*log10(excess)
1881
1882 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1883 a new option was implemented to estimate Disp (CalcDisp)
1884
1885 - ganymed: Implemented two new options which allow
1886 to overwrite the default path to search for the sequence files
1887 --ins=/magic/sequences
1888 and where to search for the image data
1889 --ind=/magic/data/star
1890
1891 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1892 dx/dy from the resource file by
1893 MSrcPosCorrect.Dx
1894 MSrcPosCorrect.Dy
1895
1896 - ganymed: fixed reading the source catalog. Only as many chars
1897 as the requested source name had were compared (If a source
1898 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1899 were requested it could happen that the coordinates of
1900 "1ES1218" were read) The source coordinates are now printed
1901 in addition to its name to the logging output.
1902
1903 - ganymed: changed the background fit in the case of a ThetaSq function
1904 from a polynomial to a exponential, this should give a big improvement
1905 for on-only analysis'
1906
1907 - ganymed/sponde: Calculation of the error of single size-/energy-
1908 bins now uses Li/Ma (5) instead of LiMa (17)
1909
1910 - sponde: Added a plot E^2*dN/dE
1911
1912 - sponde: The energy estimator plot should now show values like
1913 they are commonly used.
1914
1915 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1916 (a powerlaw with cutoff didn't work before)
1917
1918
1919
1920 *** Version 0.9.4.2 (2005/10/01)
1921
1922 - general: added new tutorial macro macros/tutorials/threshold.C:
1923 how to calculate the threshold
1924
1925 - general: added a new game. Start it from the interpreter with
1926 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1927 and MagicReversi)
1928
1929 - general: neighbor pixels in MGeoms are now sorted clockwise
1930
1931 - merpp: made aware of new format 20050829-0
1932
1933 - callisto: New scale factors from muon analysis, stored in new
1934 resource file resources/calibration.rc
1935
1936 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1937 the eventloop if something went wrong. This is necessary for the
1938 automatic processing
1939
1940 - callisto: Implemented a new treatment for the time information
1941 developed by S.Ruegamer, this should give much better response than
1942 the old very primitive algorithm. This is especially important
1943 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1944 treatment was buggy! As neighbor pixels to interpolate the
1945 arrival times always the pixels 0 to 5 were taken)
1946
1947 - callisto: In addition to the new treatment of arrival times the
1948 decision of the treatment whether a pixel contains shower
1949 information or not is used to improve the signal interpolation
1950 further. Previously interpolated pixels showed a non-zero signal
1951 do the peak searching signal extractors. Having a signal pixel
1952 beside raised the signal above the cleaning level. Thus the
1953 pixel survived cleaning to often but with a too low mean signal.
1954 By replacing empty pixels with a gaus (mean and rms from the
1955 corresponding Area entries in MPedPhotCam) this effect can
1956 be supressed.
1957
1958 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1959 got lost when the events were stored by the calibration... fixed.
1960 (This was no problem for normal image cleaning because the pixel
1961 content was artificially set to 0 not surviving standard cleaning
1962 algorithm)
1963
1964 - callisto: Fixed a bug which caused the random and peak-search pedestal
1965 extracted with an extractor to be exchanged for the first (roughly)
1966 500 events (*Extractor and *ExtractorRndm).
1967 (They were simply exchanged in callisto.cc) This bug might have been
1968 introduced in Mars 0.9.4 when the order of calculation of the two
1969 types of pedestal in callisto got exchanged. The bug only effects
1970 the first seconds of data of each sequence.
1971
1972 - star: Taking the arrival time of Muons into account the calculation
1973 of the parameters could be made independant of the noise
1974 (pedestal rms). The dependance was due to the bias of the peak search
1975 extractor. Now only a ZA dependamcy is left which is not yet fully
1976 understood.
1977
1978 - ganymed: The sequences were still not sorted correctly in any case,
1979 because they were sorted by the full qualified path name. Now they
1980 are sorted by their sequence number.
1981
1982 - ganymed: new values for the spark-event-cut
1983
1984 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1985
1986
1987
1988 *** Version 0.9.4.1 (2005/08/18)
1989
1990 - callisto: fixed some problems with the calibration in case of
1991 inteleaved events. Therefor the final and some intermediate
1992 fits are skipped which would take place on partly filled #
1993 histograms and gave wrong results or failed completely.
1994
1995 - callisto: If the intermediate finalization of the histograms
1996 calculating the mean charge of the calibration signal fails
1997 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1998
1999 - ganymed: Fixed some bugs which caused problems in On-only mode.
2000 Still the false source plot doesn't give reasonable results.
2001
2002
2003
2004 *** Version 0.9.4 (2005/08/05)
2005
2006 - general: Fixed the ZA binning. It did not correctly fit the
2007 MC binning
2008
2009 - general: Added a class to correct for the missfocussing in
2010 April (MSrcPosCorrect)
2011
2012 - general: Random Forest energy estimator should now work properly
2013
2014 - general: MHCamera now displays the profiles in deg instead of mm
2015
2016 - general: MH::SetPalette offers a lot of new palettes
2017
2018 - general: MHillas - the case of CorrXY==0 is now handled properly
2019
2020 - general: implemented the possibility to change the line and
2021 marker style of a sky-grid drawn by MAstroCatalog
2022
2023 - general: Runs in sequences and datasets are now automatically
2024 ordered (it is assumed that the order of their filenames correctly
2025 represents the order of observations) to ensure correct reading
2026 of the subsystem data
2027
2028 - general: Runs cannot be added to a sequence twice anymore. Also
2029 Sequences cannot be added twice anymore to a dataset.
2030
2031 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2032 It gave wrong results by 1./2pi
2033
2034 - showplot: got a new option to start a root interpreter, too
2035
2036 - mars: now displays a rough estimate of Disp and the third moment
2037
2038 - mars: now displays the event time MTime if available
2039
2040 - mars: show muon parameters graphically
2041
2042 - mars: now the file to open can be given as commandline
2043 argument
2044
2045 - merpp: Added support for new arehucas version >= 200507190
2046 implementing values for three temperature sensors in the
2047 counting house (MCameraAUX) and the name of the HV settings file
2048 (MCameraHV).
2049
2050 - merrp: Also fixed some problems with wrong versions numbers stated
2051 by arehucas and implemented some fixed for old versions (<200407070)
2052
2053 - callisto: MCalibrationHiLoCam can now be printed from its context
2054 menu, eg in the TBrowser
2055
2056 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2057 - 1.39 (MExtractTimeAndChargeSpline)
2058 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2059 This is important mainly for timing studies.
2060
2061 - callisto: Changed limits in MHCalibrationChargeCalc from
2062 - -100.125 to -98 (fgChargeHiGainFirst)
2063 - 1899.875 to 1902. (fgChargeHiGainLast)
2064 - -100.25 to -99 (fgChargeLoGainFirst)
2065 - 899.75 to 901. (fgChargeLoGainLast)
2066 Introduced new limits:
2067 - fgNumLoGainBlackoutLimit: 0.05
2068 - fgLoGainBlackoutLimit: 3.5
2069 - fgLoGainPickupLimit: 3.5
2070
2071 - callisto: The handling of automatic weights for the digital filter
2072 has been improved. There are now new calibration weights special
2073 for Monte Carlo calibrations.
2074
2075 - callisto: Updated Muon scale with latest results (1% difference
2076 for most data, 5% for Mar/Apr'05)
2077
2078 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2079 was saturated and the blackout-events in the low-gain exceed the
2080 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2081 This excludes those pixels which have a saturating high-gain
2082 channel, but the low-gain switch does not switch often enough
2083 to make the distribution reliable.
2084
2085 - callisto: fix a bug counting the number of saturated events. Up to now,
2086 the number of saturated slices was counted (which is one for a not too
2087 high number), but for some (pathological) pixels, many more slices
2088 saturated and produced wrong limits.
2089
2090 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2091 + MCalibrationRelTimeCam.CheckFitResults: Yes
2092 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2093 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2094 + MCalibrationRelTimeCam.CheckOscillations: Yes
2095
2096 - callisto: introduce max. number of events for intercalibration,
2097 the rest gets skipped. Default: 4096
2098 The calibration causes too many un-reliable pixels if more
2099 than about 5000 events are treated (@500 Hz) because of the
2100 mode hopping of the VCSels. However, in the past, some
2101 calibration runs have been taken (erroneously) with more
2102 than 5000 events, especially the intensity scans where
2103 a good precision is needed.
2104
2105 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2106 photo-electrons for the spline extractor by 1-2% (correctly).
2107
2108 - callisto: The intercalibration is now done using a full f-factor
2109 method instead of a simple update. This makes things slower but
2110 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2111 changes.
2112
2113 - callisto: MPedestalY3 now uses the same extraction range as the data
2114 as calculated by MPedestalY2
2115
2116 - callisto: A check of the fraction of allowed unsuitable (10%) and
2117 unreliable (30%) pixels has been addded when the conversion is
2118 calculated from interleaved events
2119
2120 - star: fixed a bug which caused MEffectiveOnTime containers not to
2121 be written. In the worst case they were skipped almost all, in the
2122 best case they were all ok. It depends on how often the new value
2123 was assigned just with an event which was skipped later by another
2124 task
2125
2126 - star: new histograms MHPointing and MHRate
2127
2128 - star: New tab (Currents) displaying the time evolution of the mean
2129 DC currents
2130
2131 - star: New tab (MeanRms) displaying the time volution of the mean
2132 Pedestal Rms
2133
2134 - star: Output now contains MReportStarguider
2135
2136 - star: Improved muon analysis. Due to the absense of a constant
2137 for the gaus fit for arc width and the fact that the arcwidth
2138 plot was a histogram instead of a profile the resulting psf
2139 became pedestal rms dependant
2140
2141 - ganymed: added new plot (MHPhi) for wobble mode as described in
2142 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2143
2144 - ganymed: corrects now (correctly?) for the misspointing in
2145 May/April 05
2146
2147 - ganymed: Two new default templates for ganymed.rc are avilable:
2148 ganymed_onoff.rc and ganymed_wobble.rc
2149
2150 - ganymed: The first version of MFMagicCuts has been released
2151
2152 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2153
2154 - ganymed, sponde: There are two new options to determin the number
2155 of bins for the signal region (NumBinsSignal) and the number of
2156 total bins (NumBinsTotal) in the MHThetaSq histogram
2157
2158 - ganymed: optimized palettes for MHDisp
2159
2160 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2161 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2162 sqrt(2) to large
2163
2164 - ganymed: The false source plot (MHDisp) is now based on Disp
2165 and a background model determined in the first loop is
2166 subtracted
2167
2168 - ganymed: MFMagicCuts are now available in the cvs. The correct
2169 solution for the disp ambiguity problem is now calculated using
2170 the third moment. The third moment cut therefor is skipped.
2171
2172 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2173 already determined by the third moment along the major axis and
2174 so its actual sign is aligned along the major axis of the shower.
2175
2176 - ganymed: If starguider data is available it is taken into account
2177 when calculating the source position. This is especially important
2178 for wobble data at high zenith angles and culmination data.
2179
2180 - ganymed: If available the starguider data is taken into account as
2181 good as it is possible without a starguider calibration. To switch
2182 it off add
2183 MPointingDevCalc.MaxAbsDev: -1
2184 to your ganymed.rc
2185
2186 - sponde: the zenith angle distribution is now weighted instead of
2187 choosen by default. This gurantees higher statistics in the highest
2188 and lowest energy bins. To switch this behaviour off use...
2189
2190 - sponde: now automatically displays the energy threshold
2191
2192
2193
2194 *** Version 0.9.3 (2005/06/03)
2195
2196 - general: MMcEvt now derived from MMcEvtBasic which should
2197 have no influence on compatibility with older camera files
2198
2199 - general: Implemented a new option to MReadReports which allows
2200 to force reading of the first event of some trees (eg. Drive-tree)
2201 before any other tree.
2202
2203 - general: Made a fix to MPointingPosCalc which assumes that the
2204 run-type is real-data if Process is called before ReInit, such
2205 that also the very first Drive-events in a run are treated
2206 correctly.
2207
2208 - shoplot now displays the filename in the title bar of the window
2209
2210 - merpp: new options: --auto-time-start --auto-time-stop which
2211 allow to cut updating with slow-control at the start- or
2212 (previousle --auto-time only allowed: and) stop-time of
2213 the run stored in the runheader.
2214
2215 - callisto: changed default of fgFallTimeHiGain in
2216 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2217 already set as default in callisto_Dec04Jan05.rc
2218
2219 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2220 now changes the filename for new weights automatically for
2221 cosmics, MC and for different calibration colors.
2222
2223 - callisto: a problem with the order of some code cause the
2224 name of the weights file in MPedestalY2 to be ignored.
2225 Wrongly the calibration_UV weights were used instead
2226 of the cosmics weights set in callisto.rc.
2227
2228 - callisto: should allow ct1 pulser data when the color is
2229 explicitly set also for pretty new runs
2230
2231 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2232 to introduce an additional scale factor (should be around 1)
2233 to adapt for slight deviations in different extractors from
2234 the MC calibration. For MC calibrations the scale factor
2235 is fixed to 1
2236
2237 - callisto: MFCosmics should handle very high signals a bit
2238 more accurate now
2239
2240 - callisto: when calculating the mean pedestal rms for different
2241 pixel sizes or sectors also kUnsuitableEvt is now taken into
2242 account - not only kUnsuitableRun
2243
2244 - callisto: '-raw' option is now the default
2245
2246 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2247 This has the advantage that mean values in the calibration (eg
2248 arrival times) are calculated more accuratly.
2249
2250 - callisto: In the resource file callisto_Dec04Jan05.rc
2251 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2252
2253 - callisto: new Hi-/Lo-Gain intercalibration constants
2254 hilocalib_sp1.root and hilocalib_sp1_mc.root
2255
2256 - callisto: changed default for MJPedestalY2.MaxEvents
2257 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2258
2259 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2260 has changed from 9.0 to 6.0. This is necessary to exclude two very
2261 ringing pixels in September which - when kept - destroy the image
2262 cleaning around them (Markus G.)
2263
2264 - callisto: (!) The Muon analysis of all data taken so far has
2265 suggested that different extractors give slightly different
2266 absolute results after calibration, due to there different
2267 handling of the calibration- and cosmics pulse shape. Although
2268 the over all calibration seems to be a bit to pesimistic (or
2269 the MC seems to be a little bit - 3-5% - too much attenuated).
2270 There for correction factors have been introduced which correct
2271 the calibration constants by
2272 0.956937799 for Digital Filter (callisto.rc)
2273 and
2274 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2275 calibration. The main advantage is, that both data types can
2276 be easily analysed together and compared to the same MC sample.
2277 The factors are choosen such, that the reference is now a
2278 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2279
2280 - star: fixed a bug which caused the first bin of the histograms
2281 vs time to disapear in PostProcess. This gave wrong results
2282 on the screen. The output and all following programs not
2283 directly accessing the histograms haven't been affected
2284
2285 - star, ganymed: Made sure that always the first Drive-tree event
2286 is read and Processed before the first data event was read.
2287
2288 - ganymed: implemented the possibility to replace the standard
2289 false source plot with a different one. For example: If
2290 you want to use a Disp based FS plot use the resource:
2291 NameHistFS: MHDisp
2292 For details about the requirements of these plots look
2293 at the corresponding classes
2294
2295 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2296 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2297 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2298 case MAlphaFitter is setup correctly. For On-Only optimization
2299 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2300 RunOn() instead of Run(). For energy estimation MJOptimize
2301 has been replaced by MJOptimizeEnergy
2302
2303 - sponde: The input MC spectrum can now be weighted to fake a
2304 different spectrum. This is done via MMcSpectrumWeight. For
2305 more details see the class description and sponde.rc
2306
2307 - sponde: The paremeter comparsion plots are not scaled by
2308 their entries anymore. Instead the MC plot is scaled by using
2309 the result spectrum of the analysis. If the input MC spectrum
2310 and the result spectrum has different slopes the absolut
2311 normalization is normally wrong.
2312
2313
2314
2315 *** Version 0.9.2 (2005/05/20)
2316
2317 - general: Changed the default paths for calibrated data and image
2318 files. (The implemented access to these files doesn't yet exist)
2319
2320 - general: support for MRunIter has been removed from the job classes
2321 (use the setter functions of MSeqeunce instead)
2322
2323 - general: ProcessFile has been renamed to Process in all job classes,
2324 because ProcessFile is missleading
2325
2326 - general: The storage of the palette in MHCamera is now possible
2327
2328 - general: new bits describing unsuitable and unreliable pixels have
2329 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2330 kDeadPedestalRms, kFluctuatingArrivalTimes
2331
2332 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2333 versions newer than V200404070
2334
2335 - general: support for cc file versions newer than V200504130. Added
2336 support for active loads (MCameraActiveLoad) and central pixel
2337 (MCameraCentralPixel)
2338
2339 - general: added new histograms for image parameters versus size
2340 (MHVsSize)
2341
2342 - general: The eventloop now automatically calls PrintStatistics
2343
2344 - Status Display: Improved support for printing:
2345 + A default can now be set in .rootrc (for more details see
2346 MStatusDisplay::PrintPS)
2347 + A print dialog is opened so that printer and command line
2348 can be canged
2349
2350 - showlog: improved such that it handles different verbosity levels
2351 more accurate now. This mean you can suppress output when
2352 using showlog.
2353
2354 - showplot: improved
2355 + The new graphics formats have been implemented
2356 (pdf, svg, png, jpg and xpm)
2357 + Implemented an interface for printing. Because you can change
2358 the printing command from the command line you can use all
2359 the nice postscript tool. To print a booklet for example call:
2360 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2361 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2362 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2363
2364 - callisto: fixed a bug in the recognition of the calibration bit
2365 pattern. Concerns only intensity calibration. (The strength of the
2366 intensity has been updated in some cases)
2367
2368 - callisto: add a filter against PIN Diode events when running over
2369 calibration runs since some of the recent calibration runs have
2370 been taken with Pin Diode.
2371
2372 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2373 39943, 44833 in the calibration (MCalibColorSet)
2374
2375 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2376 been set to 1e-18 in callisto_Dec04_Jan05.rc
2377
2378 - callisto: in callisto_Dec04Jan05.rc: set value for
2379 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2380 statistics for the calculation of the mean pulse time
2381 of the cosmisc
2382
2383 - callisto: the charge limit in the calibration has been raised
2384 from 2.5 to 4.5
2385
2386 - callisto: new setup read from callisto.rc
2387 + MCalibCalcFromPast.fNumEventsDump
2388 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2389 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2390
2391 - callisto: MExtractTimeAndChargeSpline extractor:
2392 + The integration ranges were shifted by 0.2 FADC slices to the right.
2393 + unreliable handling of floating point values caused different
2394 results on different platform or with different compiler options:
2395 The new algorithm is numerically exact and more accurate because
2396 it doesn't calculate the integration position by multiple times
2397 adding the step-size (which results in numerical uncertanties
2398 exspecially if multiplied with large numbers)
2399 + A lot of fixes have been introduced which effects integrating the
2400 spline at the edges of the valid range. In this case any memory
2401 was randomly accessed. This behaviour can be tested replacing
2402 all MArrayF by TArrayF which perform a range check (but of course
2403 they are a lot slower)
2404 ! No result obtained with the Spline before can be trusted! Due to
2405 random memory access it might by completely random!
2406
2407 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2408 + extraction range in the high gain to 4.
2409 + weights file to cosmics_weights46.dat
2410
2411 - callisto:
2412 + introduce the check for fluctuating arrival times.
2413 + set charge limit to from 2.5 to 4.5
2414 + introduce asymmetric exclusion due to "deviating number of phes":
2415 Default: -9.0 +4.5
2416 + make deviating number of phes unsuitable (see David's findings).
2417
2418 - callisto: fixed the display of unsuitable pixels. The old change
2419 to a real profile in MHCamera broke it.
2420
2421 - callisto: The cosmics filter is used in MJCalibration now
2422 independant of the pulser color (formaly it was used only for
2423 CT1-pulser data). The threshold of number of max empty pixels
2424 has been raised from 2% to 5% in MJCalibration. The maximum
2425 fraction of rejected event is 50% otherwise the calibration has
2426 failed. The filter now ignores unsuitable pixels.
2427 Setup the filter from callisto.rc using "ContCosmics"
2428 (see MFCosmics::ReadEnv)
2429
2430 - callisto: changed default for fgOffsetFromLogain back
2431 from -2.8 to -1.8 in digital filter.
2432
2433 - callisto: for the common extractors
2434 + MExtractFixedWindow
2435 * MExtractTimeAndChargeSlidingWindow
2436 * MExtractTimeAndChargeSpline
2437 * MExtractTimeAndChargeDigitalFilter
2438 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2439 and fResolutionPerPheLoGain
2440
2441 - callisto: Updated the hi-/lo-gain intercalibration constants
2442 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2443 hilocalib_df6.root
2444
2445 - callisto: The default lo-gain extraction window for the
2446 MExtractTimeAndChargeSlidingWindow extractor has been increased
2447 from 6 to 8 to take the stretch of the pusle into account
2448
2449 - callisto (!!!): fixed an important bug in the setting of the
2450 incoming pedestal pointer to the signal extractor extracting
2451 pedestals. This bug caused the pedestals not to be subtracted
2452 correctly in the calibration afterwards. The effect was about 10%
2453 too high conversion factors for the digital filter and the spline
2454 and more than 40% for the sliding window.
2455 The bug existed since end of February! (Markus G.)
2456
2457 - star: added muon support to star. A new tab "MHMuonPar" is
2458 displayed. The lower right plot is an estimate of the point spread
2459 function. A reference value is displayed. To get the real PSF
2460 you must compare with MC. The setup for the muon analysis
2461 is done in star.rc. More informations can be found in
2462 MHSingleMuon and MHCalibParCalc
2463
2464 - star: The weather data is now displayed in star
2465
2466 - star: MEventRateCalc handles the calculation of the event rate more
2467 accurate now in case of the start of a new run inside a sequence
2468
2469 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2470 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2471 changed only minimally
2472
2473 - ganymed: (MJCut and MJOptimize) now displayes the number of
2474 excess events versus size. The energy estimation is done in
2475 MJSpectrum (sponde)
2476
2477 - ganymed: got support for using other variables than Alpha, eg. Theta.
2478 Therefor you need a class deriving from MHAlpha which supports
2479 this variable (one is already existing: MHTheta, which is now the
2480 default in ganymed). It is setup through ganymed.rc
2481
2482 - added a full featured spectrum program (sponde) which reads
2483 ganymed output and monte carlos and compiles a spectrum
2484
2485
2486
2487 *** Version 0.9.1 (2005/04/14)
2488
2489 - Fix bug on the arrival time reconstruction when using Digital
2490 Filter (in some marginal cases (10%) times were reconstructed shifted
2491 by 0.2 slices)
2492
2493 - all executables now return 2 where in previous versions -1 has
2494 been returned (gave problems with shell-scripts)
2495
2496 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2497 also done with a intercalibration input file
2498
2499 - a bug in the time fine adjustment of the digital filter has been fixed
2500
2501 - a lot of small fixes to calling TPad::Divide with a margin==0
2502
2503 - MStatusDisplay now shows the memory usage
2504
2505 - added a memory leak statistic after the eventloop
2506
2507 - MHadronness replaced by MParameterD
2508
2509 - MEnergyEst replaced by MParameterD
2510
2511 - wobble mode can now be switched on from the data-set
2512
2513 - switched on bad pixel detection for a pedestal level
2514 which is more than 5 times the variance
2515
2516 - Fixed default paths to be correct for the new data center
2517
2518 - Fixed handling of drive data. The pointing position in now
2519 copied to MPointingPos inside star for real and MC events
2520
2521 - made sure, that the sequences in a dataset are sorted by
2522 their number to ensure the correct synchronization
2523
2524 - added all resource files necessary to handle spline extraction
2525 of signal for the late 2004 and the early 2005 data
2526
2527 - update the reference lines for the december data
2528
2529 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2530 This is important for the Dec. and Jan. data where the calibration
2531 pulse position changes much.
2532
2533 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2534 filter. This corrects only an defective extraction of the MC at
2535 low-gain signals lower than 90 phes.
2536
2537 - fixed some slowdown in calibrating data with interleaved events from
2538 Jan and Dec. As a workaround made the pretty palette the default.
2539 The inverse Deep Blue Sea has a bug which slows down long calibration
2540 runs a lot.
2541
2542 - implemented new values from new starguider report as defined
2543 in TDAS00-07 V7.1 (eg SkyBrighness)
2544
2545 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2546 in starguider report (If you merpp the same reports with this version
2547 you'll get the correct units (arcmin) but a different result
2548 than with old versions (wrong units))
2549
2550 - Now the status display can also write PNG, JPEG and XPM (other file
2551 formats are still unsupported by root)
2552
2553 - added a lot of scripts and macros in directory datacenter used
2554 for automatic processing
2555
2556
2557
2558 *** Version 0.9 (2005/03/23)
2559
2560 - Calibration is now done autmatically into photo-electrons like
2561 decided by the Collaboration Board
2562
2563 - Reference lines in the display can be read from resource file
2564
2565 - Interlaced calibration events can be handled by callisto
2566
2567 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2568 and applied in callisto.
2569
2570 - class MJCalibTest can be called by callisto
2571
2572 - callisto can now run with three data types: rawdata, rootdata, MC
2573
2574 - added two classes mreport/MReportStarguider.cc and
2575 mreport/MReportStarguider.h for implementing starguider-data
2576
2577 - the output of merpp-update now contains starguider information:
2578 MReportStarguider and MTimeStarguider
2579
2580 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2581 values were lower than they should. This was more visible for high
2582 energy (Size) events.
2583
2584 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2585
2586 - added a new loop to callisto to support the correct extraction of
2587 the pedestal and pedestal rms through the signal extractor
2588
2589 - added class to perform fourier tranformation of a hexagonal structure
2590 (MHexagonalFT)
2591
2592 - added class to perform fourier tranformation of a hexagonal structure
2593 in a tasklist (MHexagonalFTCalc) example: hft.C
2594
2595 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2596 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2597 small pixels, example: extendcam.C
2598
2599 - added possibility to write data to memory (TTree) using MWriteRootFile
2600
2601 - added possibility to read a TTree stored only in memory by MReadTree
2602
2603 - new classes to deal with the interleaved calibration events:
2604 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2605
2606 - implemented filters to callisto to skip calibration events
2607
2608 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2609 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2610 the slices by statistics
2611 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2612 signal extractor without randomization
2613 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2614 with the signal extractor with randomization (extraction window is
2615 randomly fixed)
2616 The three kind of pedestal is not yet implemented (for speed reasons) as
2617 long as nobody really needs it:
2618 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2619 extracted with the signal extractor with randomization
2620
2621 - callisto now finds the pulse position in the data automatically
2622
2623 - implemented data reduction in calibrated data by reducing the precision
2624 of the stored floating point values (pedestal, rms and signal) to
2625 roughly 0.5%
2626
2627 - fixed showplot to make file format conversion (eg. converting a
2628 status display stored in a root file into a postscript file) in
2629 batch mode possible:
2630 showplot -b --save-as-ps[=outfile.ps] infile.root
2631
2632 - Allow class names as part of filter rules, eg
2633 (MFSupercuts) && (MHillas.fSize>100)
2634
2635 - fixed a lot of stuff to allow all programs to process MonteCarlo
2636 camera files.
2637
2638 - enhanced possibility to debug reading of resource file
2639
2640 - MDataChain should handle priorities of operator more
2641 accurate now
2642
2643 - completely revised the container in which the signal is stored
2644 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2645 * the new implementation is faster and
2646 * needs less storage space
2647
2648 - FIRST version which can process Monte Carlos through the
2649 whole chain of programs (callisto, star, etc)
2650
2651 - implemented new image parameters for the border length of
2652 the shower image (MNewImagePar2)
2653
2654 - implemented wobble-mode in ganymed
2655
2656 - new class (MJOptimize) taking care of all optimization processes
2657
2658
2659
2660 *** Version 0.8.6 (2004/10/05)
2661
2662 - New combined signal and time extractor
2663 MExtractTimeAndChargeDigitalFilter
2664
2665 - The Report for the trigger section in the CC run summary has been
2666 updated, and now the IPRs (Individual Pixel Rates) are available.
2667
2668 - new macros for database interaction: filldotrun.C, filldotrbk.C
2669
2670 - added new program which can convert colored output which was redirected
2671 into a file back into colored text (for example to display it with
2672 more): showlog
2673
2674 - added new program to display an MStatusArray of plots (stored with
2675 MStatusDisplay) from a file: showplot
2676
2677 - Added support for Sequences (MSequence). Sequences are blocks of run
2678 files containing the same calibration and belonging to the same
2679 source
2680
2681 - Added a new task (MTaskEnv) which can be used in setup files to switch
2682 between different tasks (for example to choose a signal extractor)
2683
2684 - Implemented automatic file splitting in MWriteRootFile
2685
2686 - After image cleaning an island index is assigned to all used pixels.
2687 The index corresponds to the order of the islands in size.
2688
2689 - added a cleaning which takes signal height _and_ arrival time into
2690 account: probability cleaning (for more details see MImgCleanStd)
2691
2692 - added a cleaning which takes takes the absolute number of photons
2693 times the area ratio as cleaning level
2694 (for more details see MImgCleanStd)
2695
2696 - Changed calculation of image parameters such, that it can be done
2697 for all used pixels or the pixels with a defined island index only
2698
2699 - implemented new image parameters displaying the number of islands,
2700 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2701
2702 - event display in executable changed to support also calibrated files
2703 (done with MJCalibrateSignal)
2704
2705 - added program doing the calibration and the signal extraction
2706 and signal calibration: callisto Most part of the setup is done
2707 by a resource file: callisto.rc
2708
2709 - implemented support for pixels with negative IDs (Raw file format
2710 version 4)
2711
2712 - implemented an new option in merpp (--auto-time) to get the time
2713 range for cc and/or caco data from the run header of the raw data
2714
2715 - New star-program (star and MJStar). Taking calibrated data from
2716 callisto/MJCalibrateSignal as input. The setup is done through
2717 a resource file: star.rc
2718
2719 - Added possibility to setup the eventloop in the mars-executable
2720 Camera Display by a resource file: mars.rc
2721
2722 - The the mars-executable Camera Display can now also read
2723 calibrated data files written by callisto/MJCalibrateSignal
2724
2725 - Added a new class which can calculate the source position in
2726 the camera from a pointing model known to be correct and
2727 the pointing model used for observations (MSrcPosFromModel)
2728
2729 - added a new version of the class calculating the effective on-time
2730 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2731 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2732 MHTimeDiffTheta.
2733
2734 - added the possibility to count how often a signal is above (or
2735 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2736 can replace MHTriggerLvl0)
2737
2738 - added ore convinient ways to set the axis-titles of your histograms
2739 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2740 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2741
2742
2743
2744 *** Version 0.8.5 (2004/08/06)
2745
2746 - new Signal Extractors: MExtractFixedWindowSpline
2747 and MExtractAmplitudeSpline
2748
2749 - implementes interleave in merpp to be able to merpp parts of a file
2750
2751 - implemented force-functionality to merpp
2752
2753 - star display to display star catalogs (MAstroCatalog)
2754
2755 - star display to 'mirror' stars to the camera (MAstroCamera)
2756
2757 - implemented a new cleaning option which allows cleaning scaled with
2758 the real ratio of the rms depending on the pixel size, not only the
2759 square root of the pixelsize (MImgCleanStd, MCameraData)
2760
2761 - removed obsolete MBlind* classes
2762
2763 - Signal extractor taking the AB flag into account implemented (this makes
2764 an odd number of slices for signal extraction possible
2765 (MExtractSignalABcorr)
2766
2767 - implemented a class extracting the pedestal from the raw-data (events)
2768 itself using empty lo-gain (MpedCalcFromLoGain)
2769
2770 - Added mean values to MPedPhotCam
2771
2772 - Added Makefile for Darwin (this OS is NOT officially supported!)
2773
2774
2775
2776 *** Version 0.8.4 (2004/04/19)
2777
2778 - new fast arrival time extractor using cubic splines:
2779 MExtractTimeFastSpline
2780
2781 - implementes multi-argument support in MDataChain
2782 ("pow(a, b)")
2783
2784 - implemented double reference support in MDataChain
2785 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2786
2787 - added support in MF for expressiond like
2788 "MHillas.fWidth<2*<MHillas.fLength"
2789
2790 - MDataChain is now able to support variables like [0], [1], ...
2791 which can be used in fit functions as parameters. The interface
2792 is implemented through the new virtual function
2793 MParContainer::SetVariables
2794
2795 - added new class MArrivalTimeCam/MArrivalTimePix:
2796 Storage containers to hold the ArrivalTime of the camera/pixel
2797
2798 - added new classes for the calibration of relative arrival times:
2799 MCalibrationRelTimePix and MCalibrationRelTimeCam
2800
2801 - added new classes to extract the signal of the blind pixel and the
2802 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2803
2804 - added new classes for the bad-pixels treatment (MBadPixels*)
2805 which are more powerfull than the old ones (MBlindPixel*)
2806 and will replace them.
2807
2808 - added filter against cosmics: MFCosmics
2809
2810 - added new class MArrivalTimeCalc2:
2811 Calculates the arrival time as the signal weighted mean of the time
2812 slices in the maximum window
2813
2814 - added a new macro call pointspreadfucntion.C that fits with a 2D
2815 gaussian the DC spot for an star. It gives you the RMS of
2816 the PSF and the center of the star, very useful for misspointing
2817 studies.
2818
2819 - added support for multi-telescope camera files. Added classes
2820 MStereoCalc and MStereoPar, classes to calculate and store shower
2821 parameters calculated from the data of two telescopes, for the MC
2822 studies regarding the MAGIC clone.
2823
2824 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2825 MC data calibrated in photons instead of ADC counts.
2826
2827 - added three macros to show the calibration and analysis chain of
2828 MC data. The macro starmc.C does both calibration and analysis, producing
2829 an output containing Hillas parameters for each event. The macro
2830 mccalibrate.C does just the calibration and writes out a file containing
2831 pixel information in photons instead of FADC data. The macro starmc2.C
2832 reads in such a file and produces an output with Hillas parameters.
2833
2834 - added MPedPhotCalc to compute pedestals in units of photons, see
2835 macro pedphotcalc.C
2836
2837 - added all class to perform the calibration, see macro calibration.C
2838
2839 - added class MFFT to perform Fast Fourier Transforms
2840
2841 - added class MSimulatedAnnealing to perform simulated annealing
2842 minimizations
2843
2844 - added new macro bootcampstandardanalysis.C which holds the skeleton
2845 of the analysis chain discussed in the december bootcamp.
2846
2847 - added support for DAQ raw data file format V2
2848
2849 - implemented an arbitrary time stamp for the events from raw-data
2850 files with file version<3. It is calculated from the run number,
2851 the date of start and the FADC clock tick from the first module
2852
2853 - implemented the correct decoding of the event time-stamp
2854 coming from the DAQ for raw-data files with file-version>2
2855
2856 - added a new classes storing the pedestals in units of photons:
2857 MPedPhotPix, MPedPhotCam
2858
2859 - added support for DC current files from the camera control
2860
2861 - added support for start- and stop-time when merpping report files
2862
2863 - added MReportCC storing the weather data from the CC-REPORT
2864
2865 - added class to fill trainings and test matrices (MTFillMatrix)
2866
2867 - added a filter performing a software trigger (MFSoftwareTrigger)
2868
2869 - Added classes to perform parts of the standard analysis (Jobs):
2870 + MJPedestals
2871 + MJCalibration
2872 + MJExtractSignal
2873 Note: All of them are preliminary!
2874
2875 - Added Iterator to iterate over files giving only the run-number
2876
2877 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2878 the evolution of a sector vs time
2879
2880
2881
2882 *** Version 0.8.3 (2003/12/05)
2883
2884 - adapted Random Forest classes to allow the use with MC
2885 multi-telescope files which can be produced with the coming
2886 camera version 0.7.
2887
2888 - added classes to read and interprete central control report files
2889 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2890
2891 - enhanced merpp (the executable) to support .raw and .rep files.
2892
2893 - added classes for light calibration (MCalibration* and
2894 MHCalibration*) by Markus Gaug. Further work has to be and will
2895 be done soon.
2896
2897 - Added a preliminary 'synchronizer' (MReadReports) which will
2898 replace MReadMarsFile as soon as it is finished.
2899
2900 - Added a tutorial macro demonstrating how report files are merpped
2901 and how they can be read from the root file in the correct order
2902 of time (readrep.C)
2903
2904 - Added a generalized histogram (similar to MH3) called MVsTime
2905 which allows to plot variables (or rules - MDataChain - of
2906 variables) vs time. For an example have a look at tempvstime.C.
2907
2908 - Changed the name of the event trees:
2909 + Events --> Events
2910 + PedEvents --> Pedestals
2911 + CalEvents --> Calibration
2912
2913 - changed name of MTime in the event trees from MRawEvtTime to MTime
2914
2915 - added displaying the sector indices to the mars event display
2916
2917 - Magic Online Analysis (MOnA) implemented in a first version
2918 (see mona.cc, MOnlineDump and MOnlineDisplay)
2919
2920 - added classes to calculate event rate
2921 (preliminary: MEventRateCalc, MEventRate)
2922
2923 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2924
2925 - added classes dealing with the telescope pointing position (MPointing*)
2926
2927 - implemented the 'final' Mars time stamp based on some experiences with
2928 the new 'Synchonizer'
2929
2930
2931
2932 *** Version 0.8.2 (2003/11/10)
2933
2934 - accelerated standard analysis by a factor of 6-8 ...
2935 + doing precalculations in MGeomCam for the pixel area ratio
2936 + creating a look up table for the single pixels in MCerPhotEvt
2937
2938 - added task to calculates weights in case you want to 'change'
2939 the energy spectrum of a monte carlo file
2940 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2941
2942 - added a new executable star which implements the
2943 star.C macro as precompiled executable. Currently a flexible
2944 setup is not possible, but a 'input card' setup will follow.
2945
2946 - Starting to implement Multi-Telescope-Support based on the
2947 upcomming camera version 0.7. The base for a general support
2948 is implemented and the star-functionality is proven to work.
2949
2950 - Replaced Event-Display in and Camera-Display in the Mars GUI
2951 executable by a more convinient display base on MStatusDisplay.
2952
2953 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2954
2955
2956
2957 *** Version 0.8.1 (2003/10/20)
2958
2959 - added signal subtraction for pure on data by means of fitting
2960 the background in the off region or by performing a combined
2961 signal/background fit. Provides necessary histograms for
2962 obtaining energy spectra and a light curve.
2963
2964 - added classes to perform and study the selection of the
2965 2nd Level Trigger on MC data (example in triglvl2.C macro)
2966
2967 - added pedestal calculation
2968
2969 - implemented "democratic cleaning" (tail cut value proportional
2970 to pixel area) according to Wolfgang's suggestion.
2971
2972 - added Sigmabar treatment (calculation and basic histogramming)
2973
2974 - added basic routines to apply padding
2975
2976 - added first implementation of MARS-based source visibility plotter
2977 (needs to be linked against slalib, preliminary version)
2978
2979 - enhanced functionality of data chains: random numbers, conversion
2980 functions and access to MHMatrix objects
2981
2982 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2983 numbers under certain circumstances (runs with 0 events included)
2984
2985 - fixed a bug in the general filter MF (didn't work on some systems
2986 at all)
2987
2988 - fixed a bug in chaining files, which caused the analysis to crash or
2989 ignore files
2990
2991 - implemented more geometry classes describing the parameters used
2992 to simulate the PMT camera
2993
2994 - added new Monte Carlo classes containing the setup of the different
2995 programs in the MC chain.
2996
2997 - added a (preliminary) general task to evaluate chi-square of a given
2998 parameter in an eventloop.
2999
3000 - first implementation of a container describing the observatory
3001 location (Long, Lat, etc)
3002
3003 - added Random Forest - method for g/h-separation
3004
3005 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3006 (this means, that it is compiling, but not yet fully tested)
3007
3008 - added a new status display which can show the present status
3009 of histograms while an eventloop is running (MStatusDisplay,
3010 an example can be found at status.C)
3011
3012 - reorganized directories:
3013 classes describing the image --> mimage
3014 classes containing Monte Carlo Histograms --> mhistmc
3015 classes for Random Forest method --> mranforest
3016
3017 - added (event-)weights to fill histograms
3018
3019 - colors in logging output to screen
3020
3021 - changes to the Image Parameter declaration:
3022 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3023 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3024 + MHillasExt now derives from MParContainer instead of MHillas
3025 --> Files written with the old definition are more or less unreadable
3026
3027 - reading of reflector files
3028
3029 - display data from reflector files in the camera
3030
3031 - implemented currents (and display them in the camera)
3032
3033 - logarithmic scale in camera
3034
3035 - added class to iterate through directory contents (MDirIter)
3036
3037
3038
3039 *** Version 0.8 (2002/11/18)
3040
3041 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3042
3043 - corrected 48(!) wrong entries in the Next Neighbor table of the
3044 Magic Camera (all in the inner part of the outer ring, mostly
3045 missing a single NN)
3046
3047 - Fixed a bug in the table describing the Next Neighbours of the
3048 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3049 have any neighbour)
3050
3051 - changed trigrate.C: now it calculates the pure NSB triggers from
3052 a camera file (generated with no showers), so there is no need
3053 to introduce them by hand in the BgR array (for more details
3054 please ask Abelardo)
3055
3056 - added MHHadronness (and MHadronness) as a general facility to evaluate
3057 the quality of a gamma-hadron seperation method
3058
3059 - changed MWriteAsciiFile to accept rules (MDataChain)
3060
3061 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3062 must be replaced by calles to MWriteAsciiFile::AddColumn and
3063 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3064 changed.
3065
3066 - Implemented generalized event-matrices (one row per event)
3067 (MHMatrix)
3068
3069 - implemented the one dimensional composite probabilities
3070 (MHCompProb, MCompProbCalc, comprob.C)
3071
3072 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3073 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3074
3075 - Added a camera display displaying the pixel numbers to the
3076 event display gui.
3077
3078 - Added Monte Carlo Informations to event display gui
3079
3080 - Changed the camera display to display the pixel numbering
3081
3082 - Added three buttons to the camera display to change the palette
3083
3084 - Added the number of used and core pixels after image cleaning
3085 to MHillas
3086
3087 - Changed the algorithm used in MHillas according to TDAS 02-03
3088
3089 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3090
3091 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3092
3093 - Added fCosDeltaAlpha to MHillasSrc
3094
3095 - The numbers of photons used to calculate fConc and fConc1 in
3096 MHillasExt are now scaled with the pixel size, so that one get
3097 a four times smaller value for the bigger pixels in the outer ring.
3098
3099 - added new task to smooth the camera contents (MCameraSmooth)
3100
3101 - added possibility to use interpolated pixel values for blind pixels
3102 instead of removing it completely from the analysis
3103
3104 - Implemented the possibility to save the whole eventloop with
3105 its setup to a file. This information can be read and from
3106 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3107 and MEvtLoop::MakeMacro. If you find something not working, please
3108 report - this stuff is still in a beta phase.
3109
3110 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3111 file having crab starfield, but also for all following files - fixed
3112
3113 - MTaskList::PrintStatistics can now be instructud to print also the
3114 title, too: use PrintStatistics(0, kTRUE)
3115
3116 - Changed the image cleaning so that pixels with to many 'used'
3117 neighbors are left used (to get rid of 'holes' in events)
3118
3119 - Introduced more output to the camera displays
3120
3121 - Added an array of histograms (eg one hist per run), MHArray
3122
3123 - Added a _preliminary_ version of the reader for CT1 PreProc files
3124 (MCT1ReadPreProc)
3125
3126 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3127 (thanks to Raquel)
3128
3129 - added the first energy estimator (MEnergyEstParam, estimate.C,
3130 estfit.C) using a parametrization
3131
3132 - Added some new Monte Carlo paremeter containers used to store
3133 setup information from the MC chain (MMcConfigRunHeader,
3134 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3135
3136
3137
3138 *** Version 0.7 (2002/04/30)
3139
3140 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3141 the pedestal mean value was saved incorrectly. For files from
3142 this versions we substract 0.5 from the pedestal mean.
3143 WARNING: This may effect your results, so don't wonder...
3144
3145 - First implementation of an algorithm using only triggered events
3146 for the collection area calculation
3147
3148 - Ascii Output can now also be used for parameter containers which
3149 doesn't overload MParCointainer::AsciiWrite
3150
3151 - The Ascii Output is now also capable of writing single data members
3152 of one container
3153
3154 - You are now able to change the order of the values written to the
3155 ascii file
3156
3157 - You can now specify a conversion factor for each data member written
3158 to an ascii file. This may be usefull to change the units of the
3159 data member (eg. degrees instead of millimeters in case of the
3160 hillas parameters)
3161
3162 - Replaced old MHillas by a new structure which allows you to extend
3163 the parameters stored in MHillas very easily:
3164 see MHillas and MHillasExt
3165
3166 - Added classes to handle source dependancy of image parameters:
3167 see MHillasSrc
3168
3169 - Added container (MBinning) to have a standard input for the binning
3170 in different histograms (eg. the Energy bins should be the same in
3171 all histograms)
3172
3173 - Changed Hillas histograms from mm to deg
3174
3175 - Added the flexible binning to the hillas histograms
3176
3177 - Added a filter for the alpha parameter (MFAlpha)
3178
3179 - It is now possible to write single data members of a class object to
3180 an output stream instead of the whole container only
3181
3182 - Added a generalized filter for a data member:
3183 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3184
3185 - Added a generalized Filter parser for more difficult filter rules
3186 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3187
3188 - Added new Monte Carlo histograms:
3189 MHMcEnergyImpact and MHMcEfficiency
3190
3191 - Added many new histograms needed for the flux calculation.
3192
3193 - Added a generalized histograms which can fill and show up to three
3194 data members in either a one-, two- or three-dimensional histogram, eg:
3195 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3196
3197 - Added:
3198 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3199 * calculation of <Theta> as a function of time (MHThetabarTime)
3200 they are needed in the flux calculation in
3201 order to select for a given bin in Theta (or time) the appropriate
3202 effective collection area, which is assumed to be given as a function
3203 of Theta and the true energy
3204
3205 - Added calculation of the migration matrix in the energy
3206 (MHMcEnergyMigration):
3207 the migration matrix describes the migration from the true (E_true)
3208 to the estimated energy (E_est); it is needed to determine the
3209 distribution of E_true from the measured distribution of E_est
3210 by unfolding
3211
3212 - changed the color palette in the camera display to DeapSea.
3213
3214
3215
3216 *** Version 0.6 (2002/01/15)
3217
3218 - Introduce the option of disable pixels (MBlindPixels and
3219 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3220 able to deal with Star Field NSB.
3221
3222 - Fixed a bug in the pedestals substraction
3223
3224 - Introduced verbosity levels
3225
3226 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3227
3228 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3229 work correctly (thanks to Abelardo)
3230
3231 - Introduced correct treatment of the diffuse Night Sky Background
3232 and NSB (MMcPedestalNSB)
3233
3234 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3235
3236 - Introduced MMcRunHeaders which contains monte carlo run informations
3237
3238 - Added a 'Print'-Task (MPrint) which calls the Print function
3239 of a parameter container for each event
3240
3241 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3242
3243 - changes to be more efficient with root 3.02/06
3244
3245 - root 3.02/06 fixes:
3246 + the memory leak when reading MRawEvtData
3247 + loosing more time than necessary to update the progress bar
3248
3249 - MWriteAsciiFile is now capable of writing more than one container
3250 in a line. For example: To be able to write Monte Carlo and
3251 Hillas values (energy and alpha) in one line.
3252
3253
3254
3255 *** Version 0.5 (2001/11/06)
3256
3257 - Added new GUI functionality (Analysis)
3258
3259 - Added a camera display to be able to display events in the camera
3260 together with the calculated hillas ellipse
3261
3262 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3263 object at any state of the analysis, so that the output are several
3264 states
3265
3266 - Fixed a bug in the collection area error calculation
3267 (Thanks to Ciro and Abelardo)
3268
3269 - Fixed a bug which causes merpp to crash in some environments
3270
3271 - Implemented auto enabling scheme for Branches to speed up reading
3272 a lot (see MReadTree and MTask)
3273
3274 - Fixed a bug in the Histogram classes which caused histograms to
3275 be written to a file by MWriteRootFile without request
3276
3277 - changed the object I/O from the old stylish root I/O to the new
3278 'auto evolution scheme' This was done only for classes which are not
3279 yet used in Monte Carlo files, so that these files are still readable.
3280
3281 - Added support for a progress bar in MEvtLoop and MReadTree
3282 (see the Analysis Window in Mars for an example)
3283
3284 - Fixed a bug in the package creation which disturbed the conversion
3285 between a mars version unpacked from a tar file and the repository.
3286
3287 - Changed the code to writer merpped (converted into root format)
3288 raw files, to get faster (around 10%)
3289
3290
3291
3292 *** Version 0.4 (2001/09/20)
3293
3294 - This release is made to compile on a root version >= 3.00
3295
3296 - Fixed a bug which causes MReadTree to read the first file only
3297
3298 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3299
3300 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3301
3302 - Added a task to write several container to a root file (MWriteRootFile)
3303
3304 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3305
3306 - Added calculation of the collection area (MMcCollectionAreaCalc)
3307
3308 - fixed some bugs in the Hillas calculation
3309
3310 - added filters to be able to control the task execution dependent on
3311 a parameter (for example: the number of level 1 triggers in a MC-file)
3312
3313
3314
3315 *** Version 0.3 (2001/04/23)
3316
3317 - Many demo macros added
3318
3319 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3320
3321 - Hillas Calculation added
3322
3323 - Standard image cleaning available
3324
3325 - MReadTree is now able to handle more than one file
3326 (Remark: of the same structure)
3327
3328 - Now we are able to display events in a first version of the
3329 Camera event display. To do this we must run the macro
3330 "macros/readCT1.C" to read data from CT1.
3331
3332
3333
3334 *** Version 0.2 (2001/01/24)
3335
3336 - First Implementation of a Gui to read the raw data. Start the
3337 gui with the command mars.
3338
3339
3340
3341 *** Version 0.1 (2000/12/20)
3342
3343 - First official release 0.1
3344
3345 - Changes:
3346
3347 + changed calling style of MRawPixelIterator from do...while to
3348 while-loop
Note: See TracBrowser for help on using the repository browser.