source: trunk/MagicSoft/Mars/NEWS@ 9497

Last change on this file since 9497 was 9497, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 135.6 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 * Added consistency check for two consecutive runs
11
12 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
13 has been disconnected and the L1 (L1TPU) has directly been connected
14 to another bit in the trigger pattern. This has been fixed by an
15 update of the decoding. Both bits are now or'ed together.
16
17 * Added a new camera layout MGeomCamFact which is the "four rectangular
18 pixels ordered in a hexagonal geometry" layout
19
20 * All programs now store the command line as TNamed "CommandLine"
21
22 * the environment variable OSTYPE should now be obsolete. Instead
23 the output of "uname -s" converted to lower cases is used
24
25 ;showplot:
26
27 * If a file without a MStatusArray is opened all object (not just
28 canvases) found in the file are drawn. Note that this may result
29 in empty tabs.
30
31 ;ceres:
32
33 * The night sky noise is now scaled with the sensitive area and
34 is given in units per square centimeter
35
36 * Added the possibility to add a cut after the image parameter
37 calculation (''Cut'')
38
39 * updated the PDE of the GAPDs with a more reliable curve from
40 the meeting page (linear extrapolate below 350nm)
41
42 * The impact distribution in the event distrbutions is now
43 perpendicular to Alt/Az and the histogram is displayed in 1D
44
45 * The GAPD PDE has been updated
46
47 * PDEs and mirror reflectivities have been linearily extrapolated
48 to match the wavelegth range between 290nm and 900nm
49
50 * There is no default pulse shape anymoe it must be given in
51 the resource file
52
53 * Fixed a bug which caused the aerosol coefficient to be incorrectly
54 initialized. The effect might be random but seems to be small.
55
56 * Now accepts sequence files as input
57
58 * creation of pedestal and calibration files is now steered by
59 --mode (see ceres help)
60
61 * Instead of initializing the whole G-APD chip (all cells) before
62 each event (which is rather time consuming) a time evolution before
63 each event is now simulated which is enough to recovere every cell
64 to 99.999% of its response taking the background rate into account.
65 This is in total about a factor of ten faster and should not be
66 less accurate because under normal conditions the recovering cells
67 and the newly hitten cells will hardly be identical (due to
68 statistical reasons)
69
70 * improved the trigger algorithm which is now faster and allows easily
71 for multiplicity triggers
72
73 * The PDC flag in the file name is now correctly written
74
75 * A "PreCut" has been added which can be used after reading the events
76 to select them even before any calculation is done.
77
78 ;merpp:
79
80 * The new drive reports which contain also the status of the starguider
81 are now implemented, but the starting date (17/05/09) is preliminary.
82
83 ;callisto:
84
85 * Fixed a bug which prevented MAGIC Monte Carlo file from being
86 calibrated (ceres files worked)
87
88 ;star:
89
90 * allow to run thru even if discriminator threshold are missing
91 (they are not used for analysis so far anyway)
92
93 ;ganymed:
94
95 * added new starguider calibration for sequences since 1000534
96
97 ;database:
98
99 * added possiblity to query/plot data from certain source (with
100 regular expressions) in plotdb.php
101
102 * new feature in showplots*.php: on mouse-over additional information
103 on the sequence is displayed
104
105 ;automation:
106
107 * jobmanager can be used more flexible now: via environnent variable
108 $AUTOMATIONSETUP more than one jobmanager per user can be started
109 using the same MARS version
110 Usage: export AUTOMATIONSETUP=mysetup ; /fullpath/jobmanager
111 and provide a file Mars/datacenter/scripts/setup.mysetup
112
113
114
115== Version 2.3 (2009/03/07) ==
116
117 ;SUGGESTION
118
119 * There is no need to re-run any data because no change took place which
120 could have an effect on the output. However, if you want a
121 meaningful SrcPos plot for your MCs in sponde you must re-process
122 star for your MCs first.
123
124 ;REMARK
125
126 * File produced with this release containing a camera geometry (which
127 are basically all files were produced as default) will not be readable
128 by older releases.
129
130 ;general
131
132 * fixed a few small bugs which could cause the display to crash in ganymed
133 and sponde
134
135 * in sequence file the date can now be omittet. In this case the
136 leading date with the underscore is missing in the expected filename
137
138 * the geometry class now also supports other geometries than just hexagons
139
140 ;automation
141
142 * added magnetic field Azimuth direction (ARRANG), currently
143 at ~ -7deg at La Palma
144
145 ;database
146
147 * plotdb.php: added default (sequences) for startup, added possibility
148 to set size of plot
149
150 * added a new table ''RunDataCheck'' which containes the rates after
151 image cleaning for every run which succeeded star. It can be
152 plotted using ''plotrundb.C''
153
154 ;merpp
155
156 * added support for Arehucas Version >= 200812140
157
158 * added support for Arehucas Version >= 200809030
159
160 ;mars
161
162 * The display now also displays the trigger pattern
163
164 * The display can now display ceres reflector (_R_) files
165
166 ;ceres
167
168 * added a uniformly distributed one-bin time jitter for the start of the
169 digitization. Otherwise the first photon would be digitized always with
170 the same alignment to the bins
171
172 * Added a plot showing the production height of the photons
173
174 * Moved the particle id from the event header to the run header
175
176 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
177
178 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
179
180 * Added many new options to control the tasks. For deatils see ''ceres.rc''
181
182 * Removed obsolete plots in pedestal and calibration mode
183
184 * Removed the non-NightSky photons from the plots where they are just
185 disturbing
186
187 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
188
189 * The daq event number now represents the readout number
190
191 * The camera ''electronics'' can now be ''switched off''
192
193 * A new tab ''Info'' now display basic things like the reflector
194 layout
195
196 * Improved reading speed for corsika files
197
198 * Improved memory handling (if a large ampount of memory was needed
199 for a single event all further events were stored in the same
200 memory and it was never freed, so the program took this memory
201 until the end)
202
203 * Converted the code from MMCS' reflector program to MSimAtmosphere
204 (instead of the tables build in for MAGIC Winter and Summer
205 atmosphere we use the values written by Corsika fitted to the
206 tabulated atmosphere given as input)
207
208 * For caluclating the displayed image parameters in ceres a basic
209 image cleaning removing isolated pixels is now done.
210
211 * The magnetic field direction (ARRANG) is now taken into account
212
213 * Added plot for the energy threshold after trigger ''Threshold''
214
215 * Added plot for the effective collection area after trigger ''TrigArea''
216
217 ;star
218
219 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
220
221 * The definition of fConcCore has slightly changed. The numbers
222 might decrease a little bit (the effect should be rather small)
223
224 ;ganymed
225
226 * added pointing model 328198
227
228 ;sponde
229
230 * The SrcPos plot for your MCs was so far meaningless because it just
231 displayes the MSrcPosCam data from the input star-files. Unfortunately,
232 this containes was never written to the star-files yet.
233
234 * A new Tab 'OnTime' is available which is an effective on-time
235 fit as in star but for all data. This is mainly for manual cross-check
236 of the effective on-time
237
238 * In some circumstances it might be necessary to re-calculate the
239 eff. on-time from the fit in the new tab, e.g. when a zenith distance
240 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
241
242 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
243 it to its own output file (for convinience)
244
245
246
247== Version 2.2 (2009/01/30) ==
248
249 ;SUGGESTION
250
251 * This release doesn't contain a major change which is expected to
252 change your results. Nevertheless there are small changes to
253 the calibration which can effect at least the first few hundred
254 events in any (mainly MUX and even more SUM) sequence a little bit.
255 So it is recommended although not necessary to reset your sequences
256 in the database before further processing.
257
258 ;NEW
259
260 * A first implementation of a Monte Carlo simulation program
261 (ceres - Camera Electronics and REflector Simulation) has been
262 implemented. It can simulate a full telescope already including
263 a complete reflector simulation and a flexible trigger and readout
264 simulation. Currently, no perfect setup is implemented and
265 especially the output of the program (data structure) should
266 be considered alpha state. Also the user interface is not yet
267 ready.
268
269 ;general
270
271 * All command line options after -- are now interpreted as
272 arguments (usually everything which doesn't start with a minus)
273 rather than options (usually everything which starts with a
274 minus). This allows to use file names starting with a -
275
276 * In all resource files you can now initialize the random number
277 generator. For details see: MJob::InitRandomNumberGenerator
278
279 * added a new program called ''readcorsika''. It's purpose is (in analogy
280 to readraw and readdaq) to read a Corsika output file (for now
281 only cherenkov output is supported) and print its contents in a
282 human readable form. It can also write the contents of this file
283 into a root-file.
284
285 * The calculation of the maximum distance to the origin in a MGeomCam
286 has been improved (edges might be further away than the sides).
287 This is just a tiny change but it might change the appearance of
288 the radial profiles a little bit.
289
290 * The default binning of the center-of-gravity plot has slightly been
291 increased
292
293 ;Database
294
295 * Added informations about the DC currents (fMinCurrents, fMedCurrents
296 and fMaxCurrents). The values are retrieved from the plots showing
297 the average DC currents of all pixels versus time.
298
299 * Websites with tables have now the opportunity to remove lines
300 ('-' button at beginning of each line) and get all lines back
301 ('+' at top of the column)
302
303 * Websites: added option to query only sequences containing sumtrigger
304 events
305
306 * Websites: added option to group by date (year, month, night) for runs
307 and sequences and enabled that combining of different group-bys,
308 e.g. status, date and source is possible
309
310 ;automatic analyis
311
312 * Rewritten producing plots in the web.
313 New plots, namely the output of plotoptical.C (extinction curve from
314 KVA), plotstat.C (status of the automatic analysis (percentage of
315 processed, analysed data etc.)) and plotusage.C (statistics of the
316 condor usage in the data center) has been are available now next to the
317 plots of plotdb.C
318 Mean values from the plots (output of the macro) are provided in a
319 txt file now.
320 The creation of the plots for callisto, star and ganymed in the web is
321 now steered via database. Consequently the plots are faster and
322 reliable up-to-date.
323 For all plots, a new layout is available facilitating the browsing
324 through the plots and providing additional information on the
325 displayed values. (tabs.php) These plots are linked from the DB
326 websites and the wiki.
327
328 ;statusdisplay
329
330 * The ''Loop'' entry in the menu bar now contains an option to pause
331 the loop and to process single events.
332
333 ;merpp
334
335 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
336 instead of RunHeaders)
337
338 * Now allows to merpp files newer than 2008/09/03.
339
340 * Added fixes for wrong (wrong or double) run- and file-numbers
341 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
342
343 ;callisto
344
345 * Extracting the pulse position for the pulse position check events
346 with sum trigger were denied. This decreased the statistics
347 extremely and therefor the resulting puse position was calculated
348 quite weak. Now sum events pass the calculation if and only if they
349 have also a level 1 trigger.
350
351 * the extraction of pedestal events and pulse position from the
352 first data events is now more automatic and makes sure that
353 a more precise number of events is extracted independent of
354 the ratio with which pedestal events or events with signals
355 are contained in the data.
356
357 * Updated Muon calibration constants for all MUX data (teh changes were
358 all smaller than 5%)
359
360 ;star
361
362 * For the calculation of the effective on time all sum-triggered events
363 were skipped. Now all Level1-triggeres events will pass. This might
364 result in a slight inaccuracy of the effective on time.
365
366 ;ganymed
367
368 * If the source position is more than 1deg away from the camera
369 center an error is raised now.
370
371 * Hopefully fixed the bug ''ganymed crashes when resized''
372
373 ;sponde
374
375 * Fixed a problem which causes the fitted spectral slope to be displayed
376 incorrectly. If you use MJSpectrum::FormFlux in your macros make
377 sure that the parameter 0 of your fit is negative.
378
379 * Added a histogram showing the read source position of your MCs
380
381
382
383== Version 2.1.1 (2008/08/04) ==
384
385 ;Database
386
387 * Added the median number of photo electrons from the calibration
388 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
389 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
390
391 * Added fTotOnTime, which is the on-time as given by the run-headers
392 (in contradiction to fAbsOnTime which comes from CC)
393
394 * Added new primaries for the new data structure (Magic II): for the
395 tables dealing with sequences (SequenceBuild Status, Sequences,
396 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
397 this is the telescope number (fTelescopeNumber) for the tables dealing
398 with runs (RunData and RunProcessStatus) this is in addition the file
399 number (fFileNumber)
400
401 * Added column fPriority to the status tables to be able to steer the order
402 in which the data is processed. As default the run, sequence and dataset
403 number are used.
404
405 ;automatic analyis
406
407 * Adapted scripts to the new data structure: They can handle now different
408 telescopes (getting the information as usual from the database).
409 The paths for Magic 2 are not yet implemented.
410
411 ;general
412
413 * should work now with root 5.20/00 (please note that root 5.20/00
414 we encounter crahses in the status display which are ot yet
415 understood)
416
417 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
418 instead of the base name of the file. This makes them easier to
419 access from the code
420
421 * Default Monte Carlo names in MSequence do not require the _E at
422 the end anymore
423
424 * where abrrevating a sequence file with a sequence number is possible
425 also "telescope:sequence" is now accepted, e.g.:
426 star 2:2000123 --out=output
427 see the programs' help for more details.
428
429 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
430 from the database. See the constructors for more details.
431
432 * MReadTree now supports friends
433
434 * MReadTree can now read also files not written by MARS and store
435 the data encapsulated in emulated MParContainers
436
437 * added a new starguider calibration valid since 15.1.08
438
439 ;showplot
440
441 * showplot can now read more than one file at once. This is especially
442 inetersting if reading files containing pure canvases
443
444 ;merpp
445
446 * we merpp the dc currents now also from the camera reports (they have
447 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
448
449 * In the automatic analysis we omit merpping of the currents from the
450 caco files and use the lower rate camera reports from the cc files
451 instead
452
453 * merpp has been redisigned to allow merpping of the cc-reports
454 of a whole sequence. This allows to design a very simple analysis:
455 mkdir output
456 ./callisto 100776 --out=output
457 ./merpp 100776 output
458 ./star 100776 --ind=output --out=output
459 Instead of the sequence number also sequence files are accepted.
460
461 * Implemented a fix for run-numbers between 1001348 and 1001396
462 which were incorrectly assigned by the cc.
463
464
465 ;callisto
466
467 * added a filter again which was was removed in the last release.
468 it removed the most brightest events. This should not change
469 any analysis result because these events are so bright that
470 they cannot be analysed anyway, but the bad-pixel plots doesn't
471 show outliers.
472
473 * updated muon calibration constants for the periods 51-57,
474 58-63 and 67-
475
476 ;star
477
478 * The camera currents are now displayed with the rate of the camera
479 reports instead of the caco reports
480
481 ;ganymed
482
483 * if mc camera files are new enough (>=8) the source position in the
484 camera is now calculated from the stored telscope and shower
485 orientation (Note, that this might not be suitable in all cases
486 depending on the aim of the study. These case still needs
487 implementation)
488
489
490
491== Version 2.1 (2008/06/18) ==
492
493 ;Database
494
495 * introduced average temperature and wind speed from star-files
496
497 * introduced average values from Pyrometer (mainly Cloudiness)
498
499 * introduced the ratio of accepted calibration events in the
500 calibration run
501
502 * introduced the average rates of the different trigger pattern,
503 e.g. the rate of pedestal and calibration events, from the signal-file
504
505 ;general
506
507 * fixed GroupBy options in plot*.C macros
508
509 * only display KVA points (not the Tuorla points) in plotoptical.C
510
511 * all programs now allow to add resources to the ones from the resource
512 file or overwrite them from the command line. This can be done like this
513 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
514 if something seems to be wrong you can debug what the program is doing
515 using the option --debug-env=3
516
517 * increased the diversity of debug levels. That also means that with -v3
518 you get now less output, i.e. only the output which is important for
519 an analysis. To get more output which helps for debugging try 4, 5 and 6.
520
521 * fixed a problem in the task synchronizing the reading of the reports
522 and the data stream. The effect was that in some circumstances the last
523 events of some trees could have been skipped. Since this is only a
524 very tiny part of the data no severe effect to your analysis results
525 is expected (an exception might be very short, i.e. singel runs,
526 datasets).
527
528 * Dataset file now allow to include the sequence file directly within
529 the dataset file and also allow to exclude single runs from the dataset.
530 (for more details see Class reference of MDataSet)
531
532 * Sequence files now allow for excluding runs from the analysis
533 (for more details see Class reference of MSequence)
534
535 * added code to process the sum-trigger flag
536
537 * the histogram classes MH3 and MHn now support profile histograms
538
539 * the histogram classes MH3 and MHn now support labels at the axis
540
541 * the Random Forest Train-classes (MJTRain*) now store the used datasets
542 in the output file
543
544 * the MFMagicCuts have a new option to allow a linear area cut (for
545 special studies)
546
547 * The liniking of the shared object is now done into a file defined
548 by 'mktemp'. This should be a local file system which accelerates
549 liniking a lot.
550
551 * The code has been prepared for compilation with root 5.18/00d
552
553 * The MHEnergyEst histogram now shows the distribution of
554 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
555 and (Eest-Emc)/Emc vs Emc.
556
557 * fixed mars (event display) for merpped raw-data and MC data
558
559 * adapted the synatx of sequence files to allow for the new run/file
560 scheme. For more details see class description of MSequence
561
562 ;showplot
563
564 * Added support for tiff files
565
566 * Added support for csv files (tables containing tab number,
567 name and title)
568
569 * Tabs now can have a title which is displayed in the postscript file
570
571 * When multiple file are written at once (e.g. pngs from a display)
572 it is now possible to use the tab name and or tab number in the
573 file name. For details see showplos's help.
574
575 ;merpp
576
577 * Implemented cc file version 2008-02-20/0
578
579 * Implemented cc file version 2008-05-19/0
580
581 * With new options merpping can be restricted (in addition to the
582 run-number) also by telescope and file number.
583 For details see "merpp --help"
584
585 * Implemented raw data format 11 (the most important change, except
586 from plenty of changes in the format definition, is the addition
587 of the file-number in the header) If nobody makes a mistake this
588 format should have the advantage that it is by definition forward
589 compatible, so old programs will be able to read newer formats.
590
591 * Added Pyrometer information to default output (stored in a new Tree
592 Pyrometer, needs a complete new merpp, i.e. new calibration)
593
594 * Merpping (also update) can now be restricted to one single report.
595 For example:
596 If you want to update an old file with Pyrometer information call
597 merpp --only=Pyrometer --update
598
599 ;callisto
600
601 * in the pedestal processing now at least 50 processed events are
602 required for succeeding.
603
604 * the signal and calib files now contain also the sequence information
605
606 * the two MPedestalCam in the calib file now have proper names
607 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
608
609 * Both pedestal cams now contain the number of events processed
610
611 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
612 i.e. for the extraction of the calibration pulses basically the average
613 over all events of the first slice instead of all slices was used.
614 Since pedestal and calibration constants are continously recalculated
615 this only effected the very first events of every sequence.
616
617 * For the extraction of the position of the maximum sample now the
618 extraction range is set automatically to the extraction window,
619 before the whole accessible range was used.
620
621 * If the number of samples in the events and the number of samples
622 in the run-header disagrees now an error is raised (this can
623 happen in not well simulated Monte Carlo files)
624
625 * In the case of MUX-data pedestal events with the lvl1 trigger flag
626 could survive into the pedestal calculation -- fixed.
627
628 * Tab "TrigPat" added showing the distribution of the trigger pattern
629 as found in the run-files (normalized with the run length)
630
631 * The selection of events from the trigger pattern has been improved.
632 If the trigger pattern is corrupted events won't pass anymore.
633
634 * Added a new command line option --dev-null to suppress output of
635 Y-files (this is useful for test cases)
636
637 * added a new tab "CalPos" showing the arrival time of extracted
638 interleaved calibration events
639
640 ;star
641
642 * the star file now contains also the sequence information
643
644 * Added a new command line option --dev-null to suppress output of
645 I-files (this is useful for test cases)
646
647 * Tab "Rate" added showing the distribution of the trigger pattern
648 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
649 the Y-files (normalized with the run length)
650
651 * The effective on-time calculation doesn't use events with only
652 sum-trigger anymore
653
654 * The data in the MHWeather tab has been reorganized. The never
655 working solar radiation has been removed and the data from
656 the pyrometer (cloudiness, air and sky temperature) is
657 displayed in addition.
658
659 ;ganymed/sponde
660
661 * Now data points are even shown correctly if they have error bars larger
662 than one sigma. Points with null or negative significances are omitted.
663
664 * DrawNicePlot now allows to set a projection range
665
666 * Updates pointing models. One is applied after the implementation
667 of the new LUTS in August, the other one is applied after the
668 next major change of the pointing model in October. Note that
669 these models are preliminary and give wrong results below Zd=65deg
670
671 ;sponde
672
673 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
674
675 * a new option "--force-runtime" is available. In case of very short
676 datasets (for light-curves) which are in the order of a few
677 minutes the calculated effective on-time is not very acurate because
678 it is quantizised in the order of a minute. Therefore you can switch
679 to using the real run-time instead (remakrt: this ignores any
680 dead-time!)
681
682 * a more analytical way is used to "fill" Monte Carlos into regions
683 of impact parameters which have not been simulated because the
684 trigger efficiency is assumed to be 0.
685
686 * estimated sensitivity curves for hi and lo zenith angles are shown
687 scaled to the correct observation time and collection area
688
689 * the Monte Carlo events after cuts are now written to the output file
690 if an output file given
691
692
693
694 *** Version 2.0 (2007/09/03)
695
696 - database: the position used for the pulse pos check was missing
697 in the callisto output and could thus not be filled into the DB.
698 Also the old values seemed not exactly the PulsePos used for
699 teh check.
700
701 - general: Resource file now allow an Include-Resource, i.e. you can
702 read a resource file with default settings, include it in your
703 resource file and overwrite the settings in your file. More than
704 one include file is allowed. Inclusions can be iterative.
705 Include: mydefaults.rc yourdefaults.rc
706 The resources in the first file have higher priority than the
707 second file.
708
709 - general: Now the output files (calib*.root, etc) also contain the
710 resource file (to check it open it in the TBrowser and choose Print()
711 from the context menu)
712
713 - general: Dataset files now allow to overwrite the default path
714 to search for sequence and data files. Note, that the program
715 option and individual resources will overwrite it. For example:
716 SequencePath: /magic/montecarlo/sequences
717 DataPath: /magic/montecarlo/star
718
719 - general: Fixed a problem with variables in MDataPhrase. It seems
720 that only optimdisp (didn't work) was effected.
721
722 - general: Some improvements to the optim and train processing. For
723 example the ststud window now got a proper title.
724
725 - general: The "Status Display: " was removed from the window title
726 within an Eventloop.
727
728 - general: added a new flexible histogram-class (MHn) which can be used
729 for example in testing after optimizations or training to produce
730 user defined histograms.
731
732 - general: The Random Forest now allows attaching an evaluation
733 function which is applied to its output. This allows to train
734 on whatever you like (eg. train on log10(energy), but return
735 energy)
736
737 - general: The Random Forest training of energy (trainenergy.c) and
738 disp (traindisp.C) has been improved by more graphical output to
739 judge the result.
740
741 - general: The training of energy (trainenergy.C) has been improved
742 a lot by training on a different quantity than energy. It gives
743 a result which is highly independant of the source spectrum
744 and shows lower bias than all other options.
745
746 - general: Dataset files are allowed to contain collections of
747 datasets. For more details see the class reference of MDataSet.
748
749 - general: The default WobbleMode in a datset file now (if not
750 overwritten) is "auto", i.e. wobble mode is set if the dataset
751 doesn't contain off-sequences.
752
753 - merpp: Merpp can read file format version 9 now. Please realize
754 that for file format version 9 the extraction range is different
755 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
756 the first and last 15 slices have been removed from all MUX data.
757
758 - mars: Similar to writing movies you can now select events which
759 should be displayed in your display. Therefore add the following
760 lines to your mars.rc:
761 MFEvtNumber.FileName: ganymed00223552.root
762 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
763 The input file can be a ganymed-file after (ganymed*.root) or
764 before (ganymed*-summary.root) file. For example to select all events
765 from your on sample after cuts (excluding the ThetaSq cut) use
766 MFEvtNumber.Selector: DataType.fVal>0.5
767 To show all events from your on-sample after quality cuts
768 use the summary file instead.
769
770 - mars: new ways to call mars are implemented. Instead
771 of calling
772 mars filename.root
773 you can now also use
774 mars sequence.txt
775 or
776 mars sequence.txt inputpath
777 or replace sequence.txt by the sequence number if the default
778 sequence file should be used.
779
780 - mars: The default size has been increased
781
782 - mars: There are two new heckboxes which allow to switch off
783 the calculated image parameters
784
785 - callisto: was broken for MCs... fixed.
786
787 - callisto: improved calculation of spline coefficients a lot. This
788 leads to a further improvement of the event rate calibrating MUX
789 data of about 15% (175evt/s instead of 150evt/s)
790
791 - callisto: finally the raw data we read is now real 16bit (with
792 10bit precision) for MUX data and not a stripped 8bit number
793 anymore. Due to scaling of the numbers (without precision loss
794 into an [0-256[ range, the final numbers for pedestal, pedestalrms
795 and extacted signal don't change. However, at all places where
796 raw data is directly accessed (eg. saturation and variation
797 limits in the signal- and pedestal-extraction) the numbers
798 refer still to the data's 16bit range.
799
800 - callisto: The maximum arrival time difference used in the bad
801 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
802 for both, old FADC and MUX-FADC, data.
803
804 - callisto: Be aware that callisto is now calibrating the arrival time
805 in nanoseconds rather than time slices. Also all following tasks
806 have been changed to assume ns units now. If you star data
807 calibrated with an older version it might be necessary to adapt
808 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
809 to obtain optimal results. The plot in the PulsePos tab
810 will now be in ns, too. This might also mean that the Muon
811 analysis in star might not work as perfect as expected as long
812 as old files read in.
813
814 - callisto: The calibration constants of earlier updates got lost
815 somehow. All constants have been updated.
816
817 - star: The PSF is now determined from the profile of the ArcWidth
818 instead of arcwidth/radius. The old way gave to much weight
819 to the bins with low statistics. The reference lines have been
820 updated.
821
822 - star: For speed reasons events suitable for the muon analysis
823 are now also preselected by fConcCOG<0.1 which seems to be a very
824 good preselector for muons.
825
826 - star: is now calculating a new timing parameter the Slope along
827 the major and minor axis of the shower. Therefore a numerical
828 solution of a line-fit is used. To use MHillasExt.fSlopeLong
829 and MHillasExt.fSlopeTrans don't forget to multiply it with
830 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
831
832 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
833 have been removed from MNewImagePar. They have never been good for
834 anything.
835
836 - star: Implemented a new recursive algorithm which is supposed to be
837 faster. Also implemented new cleaning oiptions, which are:
838 + CleanLevel0:
839 The cleaning level above single core pixels can be kept
840 + KeepIsolatedPixels:
841 Define whether single core pixels should be kept
842 + TimeLevel1:
843 The coincidence window in nanoseconds to single used neighbors
844 + TimeLevel2:
845 The coincidence window in nanoseconds to two used neighbors
846 + PostCleanType:
847 MOde in which a time dependent post cleaning should be applied
848 0: No post cleaning
849 1: Require for each used pixels at least one used neighbor
850 within a time-window of CleanLevel1
851 2: Require for each used pixels at least two used neighbor
852 within a time-window of CleanLevel2
853 3: Require first two and second one used neighbor
854 within a time-window of CleanLevel1 and fCleanLevel2
855 respectively
856 + RecoverIsolatedPixels:
857 - recoveres isolated core pixels if they have a used neighbor
858
859 - mars/star: The new default cleaning is:
860 + CleanLevel1: 6.0
861 + CleanLevel2: 3.0
862 + CleanTime1: 1.75
863 + CleanTime2: 1.75
864 + PostCleanType: 3
865
866 - star/ganymed: The old spark-cuts have been replaced by new ones.
867 These new spark cuts have been cross checked with the sequences
868 84720 (before splitter), 101041 (after splitter) and 223539 (new
869 FADCs). In all cases they seperate pretty well, but of course not
870 perfect. Monte Carlos have suggested to tighten the cuts a little
871 bit further at low sizes. This has been done.
872
873 - ganymed: IMPORTANT - The spark cuts have been changed to match
874 all available data more or less well. This might mean that for
875 YOUR data there are still sparks visible.
876 Whenever you do an analysis you have to make sure that NO sparks
877 survive your cuts!
878
879 - ganymed: The old hadronness and size cuts have gotten new indices
880 (10, 11). The old indices 8 and 9 now mean an additional condition
881 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
882 If you want to switch off this cut just move the line far away enough,
883 e.g. by setting c[9] to -500. Please update your ganymed.rc files
884 accordingly!
885 The unit of c[9] is deg. It is the dist at which your cut will
886 cross the slope==0. The unit of the slope is ns/deg. So if
887 you readin files calibrated with an older Mars-version you
888 have to adapt the default value for c[9] to the FADCs:
889 - Multiply by two for the MUX FADCs (run number > 200.000)
890 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
891 - Multiply by 42 for the meaning of life (run number = 200.000)
892
893 - ganymed: The old Cut0 is now called CutQ and is calculated before
894 the source position is caluclated. If you need a quality cut
895 including source dependant data (be very carefull with this!)
896 you have to use Cut0 instead.
897
898 - ganymed: now properly supports three off regions in wobble mode.
899 It will be the default from now on in ganymed_wobble.rc. To change
900 the number of off-regions use
901 NumOffSourcePositions: 1
902 in your ganymed.rc. Also by default no off-theta cut will be done
903 anymore so that you will get a background level higher than the
904 signal level in your ThetaSq plot for ThetaSq>0.2.
905 Due to this be carefull changing the scaling mode away from
906 "None". You will underestimate your signal if your scale interval
907 is not properly set.
908 (Rem: ThetaSqN is no longer needed)
909
910 - ganymed: is now storing the events of all (on- and off-)
911 source positions even in the case of more than one off-source
912 position. This should allow sponde to work properly and the
913 energy estimation is done correctly in all cases (without any
914 "nearest position" trick)
915
916 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
917 with a real pointing model for the starguider is done, calibrated
918 with more than thousand tpoints taken from this date on.
919
920 - ganymed: was broken for Wobble-MCs... fixed.
921
922 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
923 has changed. Note that your old ganymed.rc will be incompatible
924 with the new algorithms! Please check the ganymed.rc files and
925 the class description of MFMagicCuts for more information.
926 It is recommended at the moment to use identical Disp-Parametrizations
927 for on/off- and wobble-mode. If cuts are optimized only
928 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
929 should be optimized. All other values should be kept as they are.
930 If you want to do an anylsis without timing a parameters, you can
931 switch off the timing cuts by seeting parameter 7 to a very small
932 value (eg. -99). To remove the slope parameter from the disp
933 paremtrization set parameter 8 to 0.
934
935 - ganymed: The distribution of observation time versus zenith
936 angle is now shown for off- AND on-data.
937
938 - ganymed: The contents of the source position plot are no longer
939 averaged, thus a lot of (fake) events between the two wobble
940 positions have disappeared.
941
942 - ganymed: There is a new tab "CutT" it contains the VsSize plots
943 with the CutT, whihc is defined in ganymed.rc, applied. It
944 is resonable to use your theta-cut for it, to see if there is
945 something strange (sparks!) in your signal-region.
946
947 - ganymed: To choose a dataset from a collection in a dataset file
948 use the new command line option "--dataset=12345"
949
950 - optim, sponde: should now properly support three off-regions.
951 Just produce your ganymed summary files with three off-regions.
952 optim and sponde will automatically get all off events from
953 all off-regions from this file. Please do not forget to
954 set the scaling in optimwobble.C properly:
955 fit.SetScaleUser(1./3);
956 it is not yet read in automatically (will follow soon).
957 In the case of fixed Scale you can also use
958 cuts.SetThetaCut(MFMagicCuts::kOn);
959 no off-cut needed.
960 Be carefull in case of three off-regions when switching on
961 scale mode. Make sure that the scale interval is set correctly.
962
963 - sponde: sponde.rc and sponde_onoff.rc are now idetical
964
965 - sponde: the resouce files have been rewritten with a lot of
966 comments and a well working parametrization for an energy estimator
967
968 - sponde: In the estimated energy versus monte carlo energy plot the
969 contents where exchanged.... fixed.
970
971 - sponde: the so called "accurate"-mode has been removed. It didn't
972 give any improvement in accuracy, only decreased execution speed.
973
974 - sponde: the so called "simple"-mode has been removed. It didn't
975 give any improvement in simple.
976
977 - sponde: the so called "refill"-mode has been removed. It was anyhow
978 not implemented.
979
980 - sponde: now checks whether the theta distribution of your on-data
981 and the theta-distribution of your Monte Carlo sample (after
982 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
983 sample is incomplete) execution is stopped. Execution can be forced
984 using the new option --force-theta. Use this option with care!
985
986 - sponde: Proper collection areas can now be constructed also from
987 Monte Carlo samples generated with different maximum impact
988 parameters. Note that in previous version you neither got
989 a warning or failure, nor was there any obvious sign that the
990 collection area was overestimated due to usage of files with
991 different maximum impact parameters.
992
993 - sponde: If MC files with different lower energy limits are used
994 the primary MC spectrum is artificially completed down to the
995 lowest energy used at all. WARNING: that this gives correct
996 collection areas ONLY if none of the events in this region would
997 survive your cuts at all.
998
999 - sponde: the output file now contains more information about
1000 the spectrum (eg. the full 2D collection area histogram).
1001 Note, that this information can only be written to the file
1002 if it is stored automatically via command line argument.
1003 If you only store the status display from within the display
1004 the information is lost.
1005
1006 - sponde: added a new tab "Disp". It shows the residual of the disp
1007 (Disp-Dist) versus several parameters and it is meant to judge the
1008 quality of the disp estimator. In the ideal case the residual is zero
1009 and doesn't depend on any variable. The tab is displayed after
1010 CutQ and Cut0.
1011
1012 - sponde: added a new tab "Energy". It shows the residual of the
1013 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1014 several parameters and it is meant to judge the quality of the
1015 energy estimator. In the ideal case the residual is zero
1016 and doesn't depend on any variable. In reality even a good estimator
1017 can show residuals versus Monte Carlo energy. The tab is displayed
1018 after all cuts.
1019
1020 - sponde: added a new tab "EventDist" showing the unweighted real
1021 absolute number of events of your sample after cuts. This tells
1022 you how many events with this energy you had in your MC files.
1023 The same information you get from the error bars of the weighted
1024 histograms, but this is less intuitive.
1025
1026 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1027 for comparison. It is not meant to show these curves in
1028 publications, they are only for production.
1029
1030 - sponde: The OriginalMC tree with the events produced by corsika
1031 is now processed only once
1032
1033 - sponde: Finally fixed most annoying bug, which has effected the
1034 last bin of the collection area. It was the problem that binnings
1035 of root histograms are from 1 to n (included) but there was a C-like
1036 loop in sponde from 0 to n (excluded). Now the loop also includes
1037 correctly under- and overflow-bins. The worse thing with this is,
1038 that for the events in the highest bin not only the bin-content
1039 was wrong, but also the weights applied to these events, which could
1040 in pricipal effect also other parts of the distribution (eg. due
1041 to energy estimation). Fortunately it effected only a few events
1042 in most cases.
1043
1044
1045
1046 *** Version 1.2 (2007/05/14)
1047
1048 - database: The database now has two new values Unsuitable50 and
1049 Unsuitable01. They express the number of pixels which are
1050 unsuitable for more than 50%, respectively more than 1%, of
1051 all calibrated event. It is a more accurate number than the
1052 previously used numbers, because they only take the first
1053 calibration (ignoring the interleaved calibrations) into account.
1054
1055 - database: The database now has two other new values UnsuitableMax and
1056 DeadMax. They express the maximum number of pixels which were
1057 unsuitable, respectively dead, during the sequence. Because
1058 of high pedestal rms (cars passing) a few events with very high
1059 numbers of unsuitable pixels can happen. Not to suffer from this
1060 effect we don't take the highest 0.1% of the numbers into account.
1061
1062 - general: fixed a bug which caused callisto and star to stop working
1063 properly because the callisto output was currupted
1064
1065 - general: a script called scripts/makemovie has been added which
1066 simplified the process of producing several movies from a single
1067 sequence with different setup.
1068
1069 - callisto: Some more code cleanup. Started to remove old obsolete
1070 code from cvs.
1071
1072 - callisto: The extraction of the pedestal with the extractor was
1073 not random. It seems that extracting at one position is still biased
1074 (for example in the first or last slices we could still suffer from
1075 switching noise) Now it is completely random.
1076
1077 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1078 pedestal files) individual pixels could be skipped due to high
1079 variations. This was already the case for the pedestal extraction
1080 from the lo-gains since the beginning and properly handled
1081 there, but was introduced in the extraction from the pedestal files
1082 a while ago. To calculate the average value it was still divided
1083 by the number of events procesed not by the number of summands
1084 really summed. This let to a pedestal which was a tiny amount too
1085 small (for a few piels in the order of 0.1%). This led to an slightly
1086 positive offset of the randomly extracted pedestal for a few pixels.
1087 I doubt that this has a big effect on the result, because the effect
1088 on the individual numbers is quite small. Due to this it is suggested
1089 that you rerun your calibration to make sure you are without any
1090 avoidable bias.
1091
1092 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1093 the median rms of the absolute arrival time and expressed in significance
1094 levels. This replaces the old meaning of an abolute upper limit. An
1095 absolute upper limit doesn't make much sense, because in our data
1096 all arrival times are shifted at the same time (in fact it might be
1097 a shift of the artificial trigger w.r.t. to the light flash).
1098
1099 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1100 of the number of unsuitable pixels over the whole sequence. This
1101 is usefull mainly to judge if an intermediate calibration had
1102 problems.
1103
1104 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1105 of the number of dead pixels over the whole sequence. Dead pixels
1106 in this context are unmapped pixels, i.e. pixels which could not
1107 be interpolated, and thus are ignored in the further analysis.
1108
1109 - callisto: It is now possible to use the position of the maximum
1110 of the spline as arrival time instead of the leading edge even
1111 when using the integral for the signal. Therefor set the extraction
1112 type to kIntegralRel ("IntegralRelative") and the relative height
1113 ("HeightTm") to -1:
1114 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1115 MJPedestalC1.ExtractSignal.HeightTm: -1
1116
1117
1118
1119
1120 *** Version 1.1 (2007/04/27)
1121
1122 - general: The new class MGeomCamDwarf contains the camera geometry
1123 for our prefered Dwarf camera and can be used to create general
1124 geometries of roundish or hexagonal cameras.
1125
1126 - mars: The default cleaning is now abolute 8.5/4.0.
1127
1128 - mars: The resource file mars.rc now contains examples for MUX data
1129
1130 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1131 data containing only 10-bit information is still cooked down to
1132 8-bit, by cutting away the lowest 8-bit.
1133
1134 - merpp: When reading raw data the data is now stored in a single
1135 array. The lo-gain array is obsolete. The interface stays the same.
1136
1137 - callisto: To process the new MUX data use the resource file
1138 callisto_mux.rc
1139
1140 - callisto: The -root and -raw options to read merpped raw data have
1141 been removed
1142
1143 - callisto: If the -mc option is given the sequence-name can now be
1144 replaced by the MC sequence number
1145
1146 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1147 -mc option can now be omitted
1148
1149 - callisto: Started further simplification by removing obsolete
1150 dependancies on MCalibIntensity*Cams.
1151
1152 - callisto: removed unsused intensity calibration from MJCalibration
1153 for further simplification
1154
1155 - callisto: for simplification removed references to
1156 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1157 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1158 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1159 (this should at minimum change nothing at all, and at maximum
1160 improve thing if these containers where somewhere not handled
1161 properly)
1162
1163 - callisto: Added the option to write an event movie. Please use
1164 this option with care (huge files) but exessively to understand
1165 our events. For further documentation please refer to the
1166 IACT wiki
1167 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1168
1169 - callisto: Improved binning for the pulse position check histogram
1170
1171 - callisto: The code calculating the pulse position checknow takes
1172 the pedestal into account
1173
1174 - callisto: The arrival time is now stored with full precision this
1175 helps to get rid of artefacts in histograms. For the signal this
1176 is not necessray because it is displayed in log-scale anyhow
1177
1178 - callisto: Fixed a problem with internal exclusions. Pixels which
1179 have once been marked as unsuitable didn't get the necessary
1180 histograms filled anymore to be rechecked with each interleaved
1181 calibration.
1182
1183 - callisto: The relative arrival time resolution (the rms of the
1184 relative arrival time offset) is now checked against its
1185 median and the median deviation, instead of the average
1186 plus an absolute offset.
1187
1188 - callisto: The relative arrival time offset is now calculated
1189 w.r.t. its median not w.r.t. to an artificial reference pixel.
1190
1191 - callisto: The relative time calibration now marks pixels with
1192 outlaying offset as unsuitable
1193
1194 - callisto: The interleaved relative time calibration has been switched
1195 on. The advantage is that pixels which are marked as outliers
1196 now can recover. An improvement over time is not expected, because
1197 the relative time calibration seems stable.
1198
1199 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1200 option can now be omitted.
1201
1202 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1203 or the option "-mc" is specified as default the monte carlo datacenter
1204 paths (/magic/montecarlo/...) are used if not overwritten in the
1205 dataset file.
1206
1207 - ganymed: The output files now contain run- and event-number for all
1208 events, accessible as RunNumber.fVal and EvtNumber.fVal
1209
1210 - ganymed: Added a plot showing the source position in the camera also
1211 for wobble mode
1212
1213 - ganymed: In addition to the existing task which can be setup to
1214 be executed after Cut1 a final task called "EstimateEnergy"
1215 has been added, executed before writing the final output
1216 (ganymed00000000.root). The task setup in all three cases
1217 can be choosen individually. (For all three(!) cases you
1218 can for example choose MRanForestCalc. For examples see all
1219 sponde*.rc and all ganymed*rc)
1220
1221 - ganymed: If a container "MEstimatedEnergy" is found in the
1222 parameter list (eg. because it was setup by MEstimateEnergy)
1223 it will be written to the output file.
1224
1225
1226
1227 *** Version 1.0 (2007/02/16)
1228
1229 - database: Website to plot values from the database has been added.
1230
1231 - database: The rate of spark events as found by star is now kept
1232 and the rate after cleaning is now with spark events subtracted
1233
1234 - general: The changes to the interpretation of phrases lead to
1235 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1236
1237 - general: Added example files how you can create your own calendar
1238 (eg. as christmas present) with Mars. Just run
1239 root macros/tutorials/calendar.C
1240
1241 - general: Added a possibility to display grouped data in the plotdb.C
1242 macro (and similar macros). This allows to plot hourly, nightly,
1243 weekly, monthly and yearly averages.
1244 For more details see the plotall function of the macro
1245
1246 - general: fixed the error display of the camera display. It showed
1247 wrong results.
1248
1249 - general: fixed a memory leak when reading many MStatusDisplays
1250
1251 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1252 between a spherical and a parabolic mirror
1253
1254 - callisto: We have a new pulse position check which takes the properties
1255 of the extractor automatically into account. So no need to set
1256 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1257 left is done. If possible the lo-gain extraction start and hi-gain
1258 extraction end is changed accordingly. If no proper extraction range
1259 can be set (hi-gain too much to the left) an error is raised.
1260
1261 - callisto: New swapped pixels have been found and corrected
1262
1263 - callisto: Redone the signal extraction this includes:
1264 + Unified the algorithms to extract the pedestal for all pedestal
1265 extractions done
1266 + Unification of hi- and lo-gain into one array
1267 + Unification of hi- and lo-gain extraction for Spline and
1268 Digital Filter (means now exactly the same algorithm is used,
1269 not a copy-and-pasted one)
1270 + Store pedestal subtracted data in a common place
1271 + Improved extraction algorithms. If the algorithms search a
1272 maximum but don't find one they don't return the maximum anymore
1273 + Improved the extraction such that a information for signal
1274 and time which is consistent is returned
1275 + replaced the numerical spline with a (not slower) analytical
1276 solution
1277 + Lowered the saturation limit from 250 to 245 to make sure that
1278 we are far away in all pixels from problems with the clock-noise
1279 + The start of the lo-gain extraction is calculated from the hi-gain
1280 arrival time. In case of saturation an estimation is used.
1281 + the hi-gain window was extended to slice 16. This allows extraction
1282 of very late pulses in single pixels or of huge hadron showers.
1283 + Now uses the lo-gain extraction range for pedestal extraction,
1284 not the hi-gain range in the lo-gain
1285
1286 - callisto: New hi-/lo-gain calibration constants have been produced
1287 for all periods from the statistic of the whole period. They are
1288 now used automatically depending on the periods. The old constants
1289 where deviation in avarega about 2%-3%. The constants are very
1290 stable from period to period (<<1%) except for exchanged channels.
1291 In a few cases the constants used so far were off by 1%-2% (maybe
1292 temperature effects?)
1293
1294 - callisto: To gain obsolete space we do not write the
1295 MPedestalFundamental anymore. Also calibration and bad pixel
1296 treatment is not done for it anymore because it has never been used.
1297
1298 - callisto: Fixed a bug in the seuqence handling which caused the
1299 light condition to be ignored
1300
1301 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1302 basically the same as "Cleaned" but the distribution devided into
1303 the events fullfilling a spark cut or being rejected by it.
1304 This cut can be changed from star.rc (see example inside) by
1305 the "SparkCut" directive
1306
1307 - star: Star displays now the average individual pixel-rate (IPR) versus
1308 time and the average discriminator threshold (DT) of all pixels.
1309
1310 - optim: fixed a problem with the optim-macros which was due to a bug
1311 in the new phrase parsing
1312
1313 - ganymed: To get a nice FalseSource plot (instead of the all-information
1314 debug plot displayed as a standard plot) use the context menu
1315 somewhere between the two upper plots, click on "DrawNicePlot"
1316 and enjoy the result. (It is the same context menu which contains
1317 the other options)
1318 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1319
1320 - ganymed/optim/train: The cut program, trainings- and optimization
1321 macros could run with less files found than expected from the
1322 sequence-files. No the execution is stopped in this case.
1323
1324 - ganymed: now stores the dataset in the output file with all information
1325 contained (as sequence number, sequence path, data path) so that the
1326 used dataset file can be recreated complete from the output
1327
1328 - sponde: now also allows the uasge of random forest
1329
1330 - sponde: added a plot showing the cut efficiency
1331
1332 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1333 errors (eg. effecting the collection area) because the errors of the
1334 two histograms were swapped in the calculation, which makes a difference
1335 in the case the histograms contains weighted events. Aditionally the
1336 totalarea was incorrectly taken into account, which results in too small
1337 errors, which makes a difference at low statistics were the errors
1338 or the collection area dominate.
1339
1340
1341
1342 *** Version 0.10.3 (2006/10/23)
1343
1344 - database: Implemented ObservationMode flag in websites.
1345
1346 - database: For sequences there is now also the stoptime available on the
1347 websites.
1348
1349 - database: Removed ManuallyChanged flag from sequence-info websites,
1350 as it is not needed anymore with the new sequence building algorithm.
1351
1352 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1353 Class for calculation of confidence intervals (upper limits).
1354 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1355 Please read the class instruction of TRolke for more information.
1356
1357 - general: The programs now return 0xfe if the requested resource file
1358 doesn't exist.
1359
1360 - general: Errors comming from root itself are now not output to
1361 stderr anymore but to our default (colored) log-stream.
1362
1363 - general: Changed the interface to TFormula such that now everything
1364 is parsed by TFormula, which should allow to use phrases even
1365 without paranthesis correctly parsed.
1366
1367 - callisto: replaced the AdHoc number of effective integration slices
1368 in the digital filter by an average of the correct number, averaged
1369 over all possible set of weights. This also gives correct numbers
1370 for the lo-gains which were totally wrong before.
1371
1372 - callisto: drastically reduced memory consumption by not storing
1373 all intermediate calibration results in memory anymore (we might
1374 write them into a file in the future)
1375
1376 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1377 debug plot displayed as a standard plot) use the context menu
1378 somewhere between the two upper plots, click on "DrawNicePlot"
1379 and enjoy the result. (It is the same context menu which contains
1380 the "DrawAll" option)
1381 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1382
1383
1384
1385 *** Version 0.10.2 (2006/10/15)
1386
1387 - general: changed the building of the sequence files such, that
1388 the source-/project name in case of wobble-sources is not the
1389 source/project of the first data run anymore but the new generalized
1390 wobble source/project
1391
1392 - general: Added some functions to MAstro to calculate sun and
1393 moon properties
1394
1395 - general: Added two new macros (starvisday.C and starvisyear.C)
1396 which allow to plot the visibility of several stars in one day
1397 or of one star along one year
1398
1399
1400
1401 *** Version 0.10.1 (2006/10/11)
1402
1403 - general: HTML logging output was distorted... fixed.
1404
1405 - general: Changed the writing of the sequencefiles such that only
1406 as many pedestal files as giving at least 1000 pedestal events which
1407 are nearby the first calibration run are used as pedestal runs
1408
1409 - sponde: In the calculation of the collection area(s) and the
1410 distribution for MOnte Carlo and estimated energy the error
1411 calculation was wrong because root didn't take the errors
1412 properly into account... fixed.
1413
1414
1415
1416 *** Version 0.10 (2006/10/10)
1417
1418 - general: all executables now check consistency of the root version
1419 installed with the root version used for compilation. The return
1420 code in this case is 255.
1421
1422 - general: The algorithm to build seqeunces has been redesigned
1423 completly. It is now more flexible in terms of a resource file
1424 resources/sequences.rc which can be used to partly overwrite
1425 the default algorithm and defined the important part of the
1426 algorithm. It also takes correctly into account several ways
1427 of taking wobble-data. Currently the new algorithm doesn't take
1428 the number of pedestal events anymore into account (so a sequence
1429 could have much less than 1000 pedestal events and data runs are
1430 no-more used instead)
1431
1432 - general: a lot of small changes to make the code compatible with
1433 root 5.12/00 and gcc 4.1
1434
1435 - general: Fixed some warnings thrown if more warnings are switched
1436 on in the compiler
1437
1438 - general: Added a function to MMath which returns the Median of
1439 the distribution abs(y[i]-median) but at 68:32 division instead
1440 of 50:50, which is somehow the median counterpart of the rms.
1441
1442 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1443 even if they are compressed with gzip (recommended compression
1444 is with "-1")
1445
1446 - showplot:
1447 + batch mode creation of image files now works with root 5.12/00
1448 + added support for writing bmp (though it never produces
1449 bmp which can be read by programs like xv or gimp)
1450 + added support for xml
1451 + added new option to start the display with a different size, by
1452 --display-width=nnn or --display-height=nnn
1453 + added options to define the canvas size when the display is started
1454 --canvas-width=nnn or --canvas-height=nnn
1455 the option can also be used for batch-mode conversion
1456 + added an option which automatically fits the display size to the
1457 desktop-size: --auto-size
1458
1459 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1460
1461 - merpp: allow the reports to have 1000ms due to a bug in the camera
1462 program.
1463
1464 - callisto: New swapped pixels have been found and corrected. For
1465 details see MRawRunHeader::FixAssignment()
1466
1467 - callisto: Callisto now raises an error if one of the input files could
1468 not be opened.
1469
1470 - callisto: In some rare cases it could happen that in the signal
1471 extraction of the digital filter the extractor returned nonsense
1472 results due a wrong initializion of a variable (this happens in
1473 cases in which the extracted signal is exactly zero or the
1474 digital filter couldn't slide because of a too small extraction
1475 window, which could happen in the lo-gain extraction)
1476
1477 - callisto: The lo-gains have been marked as valid in some cases
1478 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1479 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1480 smaller than the number of slices (fLoGainWindowSize) needed
1481 by the lo-gain extractor
1482
1483 - callisto: Updated absolute calibration constants (muon calibration)
1484
1485 - callisto: fixed a bug which caused the hi-gain saturation not
1486 to be handled properly in the spline (the position of the
1487 saturation was calculated incorrectly)
1488
1489 - callisto: fixed a bug which gave weird results if hi- _and_
1490 lo-gain could not be extracted properly. In some cases hi-
1491 and lo-gain have not been extracted at all and the random result
1492 got calibrated. In other cases the hi-gain was saturating and the
1493 lo-gain has not been extracted. For this a completly arbitraty
1494 scale factor was applied to the result from extracting the
1495 charge of the saturating hi-gain.
1496
1497 - callisto: improves handling of extracted signal if lo- and/or
1498 hi-gain could not be extracted properly. If no appropriate
1499 calibration of either the signal or the arrival time is possible
1500 the pixel is now markes as unsuitable instead of estimated.
1501
1502 - callisto: Fixed a problem in the spline extraction which gave
1503 weird results if the signal was extracted from the first (and
1504 highest) slice (as a workaround extraction from the first
1505 slice has been forbidden)
1506
1507 - callisto: Fixed a bug regarding the use of the QE which doesn't
1508 effect the result because the default is used anyhow.
1509 (The bug was there since 14/07/2005)
1510
1511 - callisto: Changed the default for fgLoGainStartShift to -2.4
1512
1513 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1514 factors to be always 10 for all pixels as soon as the first
1515 calibration update has happend.
1516
1517 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1518 was off by more than one slice (which gives wrong values for
1519 pixels which have saturated the hi-gain) This was a problem
1520 mainly for timing studies, not so much for the automatic standard
1521 analysis. Also the values for the Spline have been changed slightly:
1522 + Digital Filter from 1.70 to 0.95
1523 + Spline from 1.39 to 1.30
1524 The numbers were sorted out by an extensive test in the
1525 test-database.
1526
1527 - callisto: Removed the tab showing the average calibrated arrival
1528 time. It never gave useful information.
1529
1530 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1531 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1532 and both were extracted because the hi-gain was above the
1533 LoGainSwitch.
1534
1535 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1536 lo-gain pulse position (after application of LoGainOffset, which
1537 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1538 have saturated and both were extracted because the hi-gain was above
1539 the LoGainSwitch.
1540
1541 - callisto: After extensive tests a new threshold level for determination
1542 of the pulse position has been found at 50phe. This is due to the
1543 fact that for lower pulses the arrival time changes its average
1544 behaviour dramatically. It tends to the average of the extraction
1545 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1546
1547 - callisto: Added two more plots to the calibration part. The average
1548 extracted signal and the average extracted arrival time as
1549 extracted by the signal extractor (This can help debugging problems
1550 because it doesn't involve a fit)
1551
1552 - star: changed the fit for the effective on time such that initial
1553 values are calculated automatically now instead of using build
1554 in values. This makes the fit more indepedant of the underlaying
1555 rates. With a test of ~350 sequences in the test database it could
1556 be shown that the new fit gives the same result +/-1sek.
1557 The highest deviation was +5s the lowest -10s. You can now control
1558 the bahaviour with two resource values:
1559 MHEffectiveOnTime.FistBin: 3
1560 MHEffectiveOnTime.NumEvents: 12000
1561 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1562 from the resulting gamma candidates
1563
1564 - star: The Center histogram in MHHillas is now by default displayed
1565 with the colz draw-option
1566
1567 - ganymed: now produces valid error codes if failed
1568
1569 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1570 with the option "hadronness" instead of "area" or "both" if
1571 you want to use both cuts. The hadronness cut includes a fixed
1572 cut in hadronness (index 8) and a fixed cut in size (index 9).
1573
1574 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1575 the M3Long of the anti source to be not properly evaluated
1576 (actually is was evaluated as a unique random number) in case
1577 of optimization with anti-theta cut switched on. This might have
1578 lead to improper, but not necessarily wrong, optimization results.
1579
1580 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1581 how to use random forest
1582
1583 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1584 ganymed_onoff.rc. Seems to be unintentional that they were different.
1585
1586 - sponde: Since the introduction of the possibility to define a
1587 normalization energy instead of using the integral the default
1588 was not using the integral anymore but a normalization energy of
1589 1GeV. It is now the integral again.
1590
1591 - sponde: Fixed a problem in the weighting which did not allow
1592 a MC slope of -1.
1593
1594
1595
1596 *** Version 0.9.6 (2006/05/24)
1597
1598 - general: changed the binning of the azimuthal profile of the camera
1599 such that it is aligned with the 60deg boundaries.
1600
1601 - merpp: better handling of problems with the TH, TD part of the
1602 CC-REPORT for files older than 200507190 and 200412210
1603 respectively
1604
1605 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1606
1607 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1608
1609 - callisto: if an arrival time is extracted outside the fadc range is
1610 was set to the boundary before. Now a random number is assigned
1611 instead to avoid unfortunate coincidences of arrival times just
1612 by this arbitrary value.
1613
1614 - callisto: added a new option to callisto.rc which allows
1615 to set the maximum arrival time difference allowed for the
1616 badpixel algorithm to determin whether a pixels belongs to a shower:
1617 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1618
1619 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1620 to 0.9 as suggested by Stefan due to a recent study on the fraction
1621 of pixels surviving the image cleaning
1622
1623 - callisto: switched off error in case of "pulse is too much to the left"
1624
1625 - callisto: The extraction window is not adapted anymore. This means that
1626 the pulse is extracted from the full range. The draw-back is that the
1627 background (pedestal) will become slightly higher. Switching on/off
1628 the PulsePosCheck in the callisto.rc only effects filling the
1629 histograms.
1630 WARNING: If the pulse is too much to the left data is calibrated!
1631 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1632 in the database to make sure that your data is valid!
1633
1634 - star: Show also the number of stars correlated correctly by the
1635 starguider
1636
1637 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1638 than one off-source region in wobble-mode. To use it add the following to
1639 your ganymed_wobble.rc:
1640 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1641 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1642 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1643 + Cut1.ThetaCut: None
1644 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1645
1646 - ganymed: in the case the latest report is older than a default (currently
1647 one minute) and the current report will be skip the starguider
1648 correction and calibration will be reset. The maximum age can be
1649 setup from ganymed.rc by (minutes):
1650 MPointingDevCalc.MaxAge: 1.5
1651
1652 - ganymed: A first implementation showing all size-bins for the theta-sq
1653 resp. alpha-plots in a single tab automatically
1654
1655
1656
1657 *** Version 0.9.5.1 (2006/05/05)
1658
1659 - general: Added a new option "zdiff" to the Makefile which runs
1660 "cvs diff" as "make diff" would do, but with compression
1661
1662 - general: accelerated MTFillMatrix (used for eample in all training
1663 and optimization macros) by skipping some obsolete calles in the
1664 eventloop the first and second loop could be accelerated by ~20%
1665
1666 - general: Added a missing feature in the MFilterList class which
1667 prevented MFEnergySlope from working correctly in trainenergy.C
1668
1669 - general: Accelerated the random forest training and usage a bit
1670
1671 - merpp: Adapted to new raw data file format version 6
1672
1673 - merpp: fixed a problem with reading the starguider reports
1674 after 6.3.2006
1675
1676 - callisto: At some times six pixels had to be exchanged manually in the
1677 data. If the pixels to be swaped are both not found, an error was raised
1678 and calibration was stopped. Now it is assumed they are intentially not
1679 mapped and the Error has been changed to a Warning.
1680
1681 - star: Added new image cleaning based on the arrival time of the shower.
1682 The new cleaning can be accessed using the parameter "Time" instead of
1683 the the old one (like "Absolute) in the star.rc-file.
1684 Recommended parameters:
1685 + MImgCleanStd.CleanLevel1: 8.2
1686 + MImgCleanStd.CleanLevel2: 5
1687 + MImgCleanStd.CleanRings: 2
1688 + MImgCleanStd.KeepSinglePixels: No
1689
1690 - star: Simplified the calculation of the effective on time. By letting
1691 the fit start in the third bin the result should become more stable.
1692 The fit quality is now ignored for the theta-plot which is not used
1693 in the analysis later. Still better pre-cut which, for example,
1694 remove events triggered by car-light (rate changing on a short
1695 time-scale) are missing.
1696
1697 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1698 for optimization (kWeakSource) which is suggested by the Berlin
1699 people for weak sources.
1700
1701 - macros: plotdb.C:
1702 + if no dataset and no time-interval is given only sequences with
1703 an effective on-time above five minutes are plotted anymore
1704 + added a new tab "RelTime" displaying the relative on-time
1705 (effective on-time divided by the observation time)
1706
1707 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1708 the optimization became a lot faster
1709
1710 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1711 To display them just delete the pads displayed on top.
1712
1713 - ganymed: fixed a bug which could cause strange behaviour in wobble
1714 mode if no starguider information was available due to an incorrect
1715 initialization of the starguider calibration
1716
1717 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1718 be changed from within the plot. It can also be setup from the
1719 resource file using:
1720 + MHDisp.fScaleMin: 0.325
1721 + MHDisp.fScaleMax: 0.475
1722
1723 - ganymed, showplot: Fixed a problem with the fit to the off-data
1724 (HistOff) which could cause a time lag or an inifinite loop.
1725 The bug did not effect the results at all.
1726
1727 - sponde: Added a new tab showing the effective collection area after
1728 trigger (including the software trigger)
1729
1730 - sponde: MMcSpectrumWeight has a new option which allows to define
1731 the scaling factor not by the integral of the events but at
1732 a defined energy:
1733 e.g. MMcSpectrumWeight.NormEnergy: 200
1734
1735 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1736 eventloops the loop could be accelerated by ~20%
1737
1738
1739
1740 *** Version 0.9.5 (2006/03/13)
1741
1742 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1743 and added the standard Disp-parametrization
1744
1745 - macros: added a new macro datacenter/macros/plotstat.C allowing
1746 to plot statistics about the data processing
1747
1748 - macros: added a new macro to plot the muon correction coefficients
1749 versus period (macros/plot/mucal.C)
1750
1751 - showplot: path inflation for ganymed files was broken
1752
1753 - callisto: Fixed an important bug. When the number of saturating pixels
1754 were calculated the bad pixel information already available from the
1755 calibration was ignored. This yields wrong values in case pixels
1756 are broken and saturate all the time or randomly.
1757
1758 - callisto: Updated Muon calibration constants. Spline data now also uses
1759 different values for different periods
1760
1761 - star: The time-evolution shown in the effective on-time plot now displays
1762 the axis range (if there are no holes it should be similar to the
1763 effective on-time)
1764
1765 - star: Added two new image parameters:
1766 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1767 the three pixels next to the center of gravity and the size
1768 + MNewImagePar.fConcCore: The ratio of the signals of all
1769 pixels inside or touching the ellipse and the size
1770
1771 - ganymed: now stops in requested source isn't found in catalog file
1772
1773 - ganymed: Many improvements to the phi-plot in wobble mode:
1774 + with a template the ideal background is displayed
1775 + a possible camera inhomogeneity is taken into account
1776 + the anti theta cut is better supported
1777 + the phi cut is automatically calculated from the theta cut
1778 See the examples in ganymed_wobble.rc for more details.
1779
1780 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1781 times the bin-width instead of the absolute energy
1782
1783 - ganymed: New cuts for on/off and wobble mode
1784
1785 - ganymed: The smearing of the False Source plot has been increased
1786 to 0.06
1787
1788 - ganymed: The starguider calibration can now be changed from the
1789 resource file.
1790 See the examples in ganymed*.rc for more details.
1791
1792 - ganymed: added a new option for on-/off-observations
1793 MJCut.RandomSourcePosition
1794 If switched on the distribution of observation time of the source
1795 position in the camera is calculated from the on-data and randomly
1796 applied with this distrbution to the off-data.
1797
1798 - ganymed: by skipping some obsolete calles in the eventloop the
1799 first and second loop could be accelerated by ~20%
1800
1801 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1802 position in the off-data randomly according to its distribution in the
1803 on-data.
1804
1805
1806
1807 *** Version 0.9.4.3 (2006/02/13)
1808
1809 - general: Fixed a bug in most of the programs which prevented the
1810 compile date in the startup message to be displayed
1811
1812 - general: Simplified program calls. The following abbreviations
1813 are now possible:
1814 showlog callisto 55599
1815 showplot signal 55599
1816 star 55599
1817 callisto 55999
1818 ganymed 2
1819 In this cases the corrsponding root-, log-, sequence- or dataset-
1820 filename is automatically compiled using the default datacenter
1821 paths ("/magic/*")
1822
1823 - general: Fixed a long outstanding bug which made axis tick marks
1824 disappear if MDataFormula was used (eg. abs(x))
1825
1826 - general: Updated MMath with new functions to calculate the results of
1827 a exponential, logarithmic and powerlaw fits analytically.
1828
1829 - general: Updated some macros with comments:
1830 + macros/optim/optimdisp.C
1831 + macros/optim/optimenergy.C
1832 + macros/optim/optimwobble.C:
1833
1834 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1835 files) now allows adding a pre-cut like in the optimization. E.g. this
1836 is useful to perform g/h-separation cuts before training the random
1837 forest.
1838
1839 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1840 correctly assigned in the raw data assignement table. A fix to correct
1841 the assignment tabel have been implemented.
1842
1843 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1844 by 90, 180 and 270 deg.
1845
1846 - general: the macro plotdb.C now allows to highlight sequences belonging
1847 to a datset. For more details see the descritions in the macro.
1848
1849 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1850 of the display, it gave wrong results espacially for big sizes.
1851 Now the embedded canvas should always have a ratio width/height=3/2.
1852 The "Size" options have been updated with values fitting the 3/2
1853 size ratio.
1854
1855 - RanForest:
1856 + Updated the random forest classes to support also the
1857 regression method implemented by Thomas H.
1858 + added new tutorial macro how to train the random forest
1859 for energy estimation (macros/optim/rfenergyest.C)
1860 + new classes to train the random forest (still in development)
1861 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1862 + new tutorial macros for random forest training in macros/train
1863 trainenergy.C, traindisp.C, trainseparation.C
1864
1865 - mars: now allows to setup a cut in the resource file mars.rc to choose
1866 the events to be displayed, eg:
1867 Cut.Condition: {0} && {1}
1868 Cut.0: MHillas.fSize>100
1869 Cut.1: MHillas.fSize<900
1870
1871 - merpp: Made aware of the new .rep format 200510250. This includes
1872 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1873 the discriminator thresholds (MCameraTD) and the disciminator
1874 delays (MCameraTD). All of them come with the CC report and are therefor
1875 written to the CC tree.
1876
1877 - callisto: fixed a bug in the calculation of the arrival times in
1878 the Digital Filter. They were all shifted by the same amount
1879 fHiGainFirst. This caused an offset in the order of the position of
1880 the left border of the extraction window in the times calculated
1881 from high-gain and from low-gain. The bug effected only the absolute
1882 arrival times. The bug was there since 30.1.2005.
1883
1884 - callisto: Changed the ExtractionWindow for the pulse position check
1885 such that the camera inhomogeneity becomes as less as possible and
1886 comparable to the pulso position check switched off. More details
1887 on the study will be given at our result web-page.
1888
1889 - ganymed: ganymed.rc, ganymed_onoff.rc:
1890 changed to new cuts trained with 1ES1218 and Crab-data
1891 for maximum sigma*log10(excess)
1892
1893 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1894 a new option was implemented to estimate Disp (CalcDisp)
1895
1896 - ganymed: Implemented two new options which allow
1897 to overwrite the default path to search for the sequence files
1898 --ins=/magic/sequences
1899 and where to search for the image data
1900 --ind=/magic/data/star
1901
1902 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1903 dx/dy from the resource file by
1904 MSrcPosCorrect.Dx
1905 MSrcPosCorrect.Dy
1906
1907 - ganymed: fixed reading the source catalog. Only as many chars
1908 as the requested source name had were compared (If a source
1909 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1910 were requested it could happen that the coordinates of
1911 "1ES1218" were read) The source coordinates are now printed
1912 in addition to its name to the logging output.
1913
1914 - ganymed: changed the background fit in the case of a ThetaSq function
1915 from a polynomial to a exponential, this should give a big improvement
1916 for on-only analysis'
1917
1918 - ganymed/sponde: Calculation of the error of single size-/energy-
1919 bins now uses Li/Ma (5) instead of LiMa (17)
1920
1921 - sponde: Added a plot E^2*dN/dE
1922
1923 - sponde: The energy estimator plot should now show values like
1924 they are commonly used.
1925
1926 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1927 (a powerlaw with cutoff didn't work before)
1928
1929
1930
1931 *** Version 0.9.4.2 (2005/10/01)
1932
1933 - general: added new tutorial macro macros/tutorials/threshold.C:
1934 how to calculate the threshold
1935
1936 - general: added a new game. Start it from the interpreter with
1937 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1938 and MagicReversi)
1939
1940 - general: neighbor pixels in MGeoms are now sorted clockwise
1941
1942 - merpp: made aware of new format 20050829-0
1943
1944 - callisto: New scale factors from muon analysis, stored in new
1945 resource file resources/calibration.rc
1946
1947 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1948 the eventloop if something went wrong. This is necessary for the
1949 automatic processing
1950
1951 - callisto: Implemented a new treatment for the time information
1952 developed by S.Ruegamer, this should give much better response than
1953 the old very primitive algorithm. This is especially important
1954 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1955 treatment was buggy! As neighbor pixels to interpolate the
1956 arrival times always the pixels 0 to 5 were taken)
1957
1958 - callisto: In addition to the new treatment of arrival times the
1959 decision of the treatment whether a pixel contains shower
1960 information or not is used to improve the signal interpolation
1961 further. Previously interpolated pixels showed a non-zero signal
1962 do the peak searching signal extractors. Having a signal pixel
1963 beside raised the signal above the cleaning level. Thus the
1964 pixel survived cleaning to often but with a too low mean signal.
1965 By replacing empty pixels with a gaus (mean and rms from the
1966 corresponding Area entries in MPedPhotCam) this effect can
1967 be supressed.
1968
1969 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1970 got lost when the events were stored by the calibration... fixed.
1971 (This was no problem for normal image cleaning because the pixel
1972 content was artificially set to 0 not surviving standard cleaning
1973 algorithm)
1974
1975 - callisto: Fixed a bug which caused the random and peak-search pedestal
1976 extracted with an extractor to be exchanged for the first (roughly)
1977 500 events (*Extractor and *ExtractorRndm).
1978 (They were simply exchanged in callisto.cc) This bug might have been
1979 introduced in Mars 0.9.4 when the order of calculation of the two
1980 types of pedestal in callisto got exchanged. The bug only effects
1981 the first seconds of data of each sequence.
1982
1983 - star: Taking the arrival time of Muons into account the calculation
1984 of the parameters could be made independant of the noise
1985 (pedestal rms). The dependance was due to the bias of the peak search
1986 extractor. Now only a ZA dependamcy is left which is not yet fully
1987 understood.
1988
1989 - ganymed: The sequences were still not sorted correctly in any case,
1990 because they were sorted by the full qualified path name. Now they
1991 are sorted by their sequence number.
1992
1993 - ganymed: new values for the spark-event-cut
1994
1995 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1996
1997
1998
1999 *** Version 0.9.4.1 (2005/08/18)
2000
2001 - callisto: fixed some problems with the calibration in case of
2002 inteleaved events. Therefor the final and some intermediate
2003 fits are skipped which would take place on partly filled #
2004 histograms and gave wrong results or failed completely.
2005
2006 - callisto: If the intermediate finalization of the histograms
2007 calculating the mean charge of the calibration signal fails
2008 it is counted now and printed in PostProcess of MCalibCalcFromPast.
2009
2010 - ganymed: Fixed some bugs which caused problems in On-only mode.
2011 Still the false source plot doesn't give reasonable results.
2012
2013
2014
2015 *** Version 0.9.4 (2005/08/05)
2016
2017 - general: Fixed the ZA binning. It did not correctly fit the
2018 MC binning
2019
2020 - general: Added a class to correct for the missfocussing in
2021 April (MSrcPosCorrect)
2022
2023 - general: Random Forest energy estimator should now work properly
2024
2025 - general: MHCamera now displays the profiles in deg instead of mm
2026
2027 - general: MH::SetPalette offers a lot of new palettes
2028
2029 - general: MHillas - the case of CorrXY==0 is now handled properly
2030
2031 - general: implemented the possibility to change the line and
2032 marker style of a sky-grid drawn by MAstroCatalog
2033
2034 - general: Runs in sequences and datasets are now automatically
2035 ordered (it is assumed that the order of their filenames correctly
2036 represents the order of observations) to ensure correct reading
2037 of the subsystem data
2038
2039 - general: Runs cannot be added to a sequence twice anymore. Also
2040 Sequences cannot be added twice anymore to a dataset.
2041
2042 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2043 It gave wrong results by 1./2pi
2044
2045 - showplot: got a new option to start a root interpreter, too
2046
2047 - mars: now displays a rough estimate of Disp and the third moment
2048
2049 - mars: now displays the event time MTime if available
2050
2051 - mars: show muon parameters graphically
2052
2053 - mars: now the file to open can be given as commandline
2054 argument
2055
2056 - merpp: Added support for new arehucas version >= 200507190
2057 implementing values for three temperature sensors in the
2058 counting house (MCameraAUX) and the name of the HV settings file
2059 (MCameraHV).
2060
2061 - merrp: Also fixed some problems with wrong versions numbers stated
2062 by arehucas and implemented some fixed for old versions (<200407070)
2063
2064 - callisto: MCalibrationHiLoCam can now be printed from its context
2065 menu, eg in the TBrowser
2066
2067 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2068 - 1.39 (MExtractTimeAndChargeSpline)
2069 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2070 This is important mainly for timing studies.
2071
2072 - callisto: Changed limits in MHCalibrationChargeCalc from
2073 - -100.125 to -98 (fgChargeHiGainFirst)
2074 - 1899.875 to 1902. (fgChargeHiGainLast)
2075 - -100.25 to -99 (fgChargeLoGainFirst)
2076 - 899.75 to 901. (fgChargeLoGainLast)
2077 Introduced new limits:
2078 - fgNumLoGainBlackoutLimit: 0.05
2079 - fgLoGainBlackoutLimit: 3.5
2080 - fgLoGainPickupLimit: 3.5
2081
2082 - callisto: The handling of automatic weights for the digital filter
2083 has been improved. There are now new calibration weights special
2084 for Monte Carlo calibrations.
2085
2086 - callisto: Updated Muon scale with latest results (1% difference
2087 for most data, 5% for Mar/Apr'05)
2088
2089 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2090 was saturated and the blackout-events in the low-gain exceed the
2091 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2092 This excludes those pixels which have a saturating high-gain
2093 channel, but the low-gain switch does not switch often enough
2094 to make the distribution reliable.
2095
2096 - callisto: fix a bug counting the number of saturated events. Up to now,
2097 the number of saturated slices was counted (which is one for a not too
2098 high number), but for some (pathological) pixels, many more slices
2099 saturated and produced wrong limits.
2100
2101 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2102 + MCalibrationRelTimeCam.CheckFitResults: Yes
2103 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2104 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2105 + MCalibrationRelTimeCam.CheckOscillations: Yes
2106
2107 - callisto: introduce max. number of events for intercalibration,
2108 the rest gets skipped. Default: 4096
2109 The calibration causes too many un-reliable pixels if more
2110 than about 5000 events are treated (@500 Hz) because of the
2111 mode hopping of the VCSels. However, in the past, some
2112 calibration runs have been taken (erroneously) with more
2113 than 5000 events, especially the intensity scans where
2114 a good precision is needed.
2115
2116 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2117 photo-electrons for the spline extractor by 1-2% (correctly).
2118
2119 - callisto: The intercalibration is now done using a full f-factor
2120 method instead of a simple update. This makes things slower but
2121 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2122 changes.
2123
2124 - callisto: MPedestalY3 now uses the same extraction range as the data
2125 as calculated by MPedestalY2
2126
2127 - callisto: A check of the fraction of allowed unsuitable (10%) and
2128 unreliable (30%) pixels has been addded when the conversion is
2129 calculated from interleaved events
2130
2131 - star: fixed a bug which caused MEffectiveOnTime containers not to
2132 be written. In the worst case they were skipped almost all, in the
2133 best case they were all ok. It depends on how often the new value
2134 was assigned just with an event which was skipped later by another
2135 task
2136
2137 - star: new histograms MHPointing and MHRate
2138
2139 - star: New tab (Currents) displaying the time evolution of the mean
2140 DC currents
2141
2142 - star: New tab (MeanRms) displaying the time volution of the mean
2143 Pedestal Rms
2144
2145 - star: Output now contains MReportStarguider
2146
2147 - star: Improved muon analysis. Due to the absense of a constant
2148 for the gaus fit for arc width and the fact that the arcwidth
2149 plot was a histogram instead of a profile the resulting psf
2150 became pedestal rms dependant
2151
2152 - ganymed: added new plot (MHPhi) for wobble mode as described in
2153 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2154
2155 - ganymed: corrects now (correctly?) for the misspointing in
2156 May/April 05
2157
2158 - ganymed: Two new default templates for ganymed.rc are avilable:
2159 ganymed_onoff.rc and ganymed_wobble.rc
2160
2161 - ganymed: The first version of MFMagicCuts has been released
2162
2163 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2164
2165 - ganymed, sponde: There are two new options to determin the number
2166 of bins for the signal region (NumBinsSignal) and the number of
2167 total bins (NumBinsTotal) in the MHThetaSq histogram
2168
2169 - ganymed: optimized palettes for MHDisp
2170
2171 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2172 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2173 sqrt(2) to large
2174
2175 - ganymed: The false source plot (MHDisp) is now based on Disp
2176 and a background model determined in the first loop is
2177 subtracted
2178
2179 - ganymed: MFMagicCuts are now available in the cvs. The correct
2180 solution for the disp ambiguity problem is now calculated using
2181 the third moment. The third moment cut therefor is skipped.
2182
2183 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2184 already determined by the third moment along the major axis and
2185 so its actual sign is aligned along the major axis of the shower.
2186
2187 - ganymed: If starguider data is available it is taken into account
2188 when calculating the source position. This is especially important
2189 for wobble data at high zenith angles and culmination data.
2190
2191 - ganymed: If available the starguider data is taken into account as
2192 good as it is possible without a starguider calibration. To switch
2193 it off add
2194 MPointingDevCalc.MaxAbsDev: -1
2195 to your ganymed.rc
2196
2197 - sponde: the zenith angle distribution is now weighted instead of
2198 choosen by default. This gurantees higher statistics in the highest
2199 and lowest energy bins. To switch this behaviour off use...
2200
2201 - sponde: now automatically displays the energy threshold
2202
2203
2204
2205 *** Version 0.9.3 (2005/06/03)
2206
2207 - general: MMcEvt now derived from MMcEvtBasic which should
2208 have no influence on compatibility with older camera files
2209
2210 - general: Implemented a new option to MReadReports which allows
2211 to force reading of the first event of some trees (eg. Drive-tree)
2212 before any other tree.
2213
2214 - general: Made a fix to MPointingPosCalc which assumes that the
2215 run-type is real-data if Process is called before ReInit, such
2216 that also the very first Drive-events in a run are treated
2217 correctly.
2218
2219 - shoplot now displays the filename in the title bar of the window
2220
2221 - merpp: new options: --auto-time-start --auto-time-stop which
2222 allow to cut updating with slow-control at the start- or
2223 (previousle --auto-time only allowed: and) stop-time of
2224 the run stored in the runheader.
2225
2226 - callisto: changed default of fgFallTimeHiGain in
2227 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2228 already set as default in callisto_Dec04Jan05.rc
2229
2230 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2231 now changes the filename for new weights automatically for
2232 cosmics, MC and for different calibration colors.
2233
2234 - callisto: a problem with the order of some code cause the
2235 name of the weights file in MPedestalY2 to be ignored.
2236 Wrongly the calibration_UV weights were used instead
2237 of the cosmics weights set in callisto.rc.
2238
2239 - callisto: should allow ct1 pulser data when the color is
2240 explicitly set also for pretty new runs
2241
2242 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2243 to introduce an additional scale factor (should be around 1)
2244 to adapt for slight deviations in different extractors from
2245 the MC calibration. For MC calibrations the scale factor
2246 is fixed to 1
2247
2248 - callisto: MFCosmics should handle very high signals a bit
2249 more accurate now
2250
2251 - callisto: when calculating the mean pedestal rms for different
2252 pixel sizes or sectors also kUnsuitableEvt is now taken into
2253 account - not only kUnsuitableRun
2254
2255 - callisto: '-raw' option is now the default
2256
2257 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2258 This has the advantage that mean values in the calibration (eg
2259 arrival times) are calculated more accuratly.
2260
2261 - callisto: In the resource file callisto_Dec04Jan05.rc
2262 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2263
2264 - callisto: new Hi-/Lo-Gain intercalibration constants
2265 hilocalib_sp1.root and hilocalib_sp1_mc.root
2266
2267 - callisto: changed default for MJPedestalY2.MaxEvents
2268 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2269
2270 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2271 has changed from 9.0 to 6.0. This is necessary to exclude two very
2272 ringing pixels in September which - when kept - destroy the image
2273 cleaning around them (Markus G.)
2274
2275 - callisto: (!) The Muon analysis of all data taken so far has
2276 suggested that different extractors give slightly different
2277 absolute results after calibration, due to there different
2278 handling of the calibration- and cosmics pulse shape. Although
2279 the over all calibration seems to be a bit to pesimistic (or
2280 the MC seems to be a little bit - 3-5% - too much attenuated).
2281 There for correction factors have been introduced which correct
2282 the calibration constants by
2283 0.956937799 for Digital Filter (callisto.rc)
2284 and
2285 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2286 calibration. The main advantage is, that both data types can
2287 be easily analysed together and compared to the same MC sample.
2288 The factors are choosen such, that the reference is now a
2289 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2290
2291 - star: fixed a bug which caused the first bin of the histograms
2292 vs time to disapear in PostProcess. This gave wrong results
2293 on the screen. The output and all following programs not
2294 directly accessing the histograms haven't been affected
2295
2296 - star, ganymed: Made sure that always the first Drive-tree event
2297 is read and Processed before the first data event was read.
2298
2299 - ganymed: implemented the possibility to replace the standard
2300 false source plot with a different one. For example: If
2301 you want to use a Disp based FS plot use the resource:
2302 NameHistFS: MHDisp
2303 For details about the requirements of these plots look
2304 at the corresponding classes
2305
2306 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2307 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2308 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2309 case MAlphaFitter is setup correctly. For On-Only optimization
2310 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2311 RunOn() instead of Run(). For energy estimation MJOptimize
2312 has been replaced by MJOptimizeEnergy
2313
2314 - sponde: The input MC spectrum can now be weighted to fake a
2315 different spectrum. This is done via MMcSpectrumWeight. For
2316 more details see the class description and sponde.rc
2317
2318 - sponde: The paremeter comparsion plots are not scaled by
2319 their entries anymore. Instead the MC plot is scaled by using
2320 the result spectrum of the analysis. If the input MC spectrum
2321 and the result spectrum has different slopes the absolut
2322 normalization is normally wrong.
2323
2324
2325
2326 *** Version 0.9.2 (2005/05/20)
2327
2328 - general: Changed the default paths for calibrated data and image
2329 files. (The implemented access to these files doesn't yet exist)
2330
2331 - general: support for MRunIter has been removed from the job classes
2332 (use the setter functions of MSeqeunce instead)
2333
2334 - general: ProcessFile has been renamed to Process in all job classes,
2335 because ProcessFile is missleading
2336
2337 - general: The storage of the palette in MHCamera is now possible
2338
2339 - general: new bits describing unsuitable and unreliable pixels have
2340 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2341 kDeadPedestalRms, kFluctuatingArrivalTimes
2342
2343 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2344 versions newer than V200404070
2345
2346 - general: support for cc file versions newer than V200504130. Added
2347 support for active loads (MCameraActiveLoad) and central pixel
2348 (MCameraCentralPixel)
2349
2350 - general: added new histograms for image parameters versus size
2351 (MHVsSize)
2352
2353 - general: The eventloop now automatically calls PrintStatistics
2354
2355 - Status Display: Improved support for printing:
2356 + A default can now be set in .rootrc (for more details see
2357 MStatusDisplay::PrintPS)
2358 + A print dialog is opened so that printer and command line
2359 can be canged
2360
2361 - showlog: improved such that it handles different verbosity levels
2362 more accurate now. This mean you can suppress output when
2363 using showlog.
2364
2365 - showplot: improved
2366 + The new graphics formats have been implemented
2367 (pdf, svg, png, jpg and xpm)
2368 + Implemented an interface for printing. Because you can change
2369 the printing command from the command line you can use all
2370 the nice postscript tool. To print a booklet for example call:
2371 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2372 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2373 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2374
2375 - callisto: fixed a bug in the recognition of the calibration bit
2376 pattern. Concerns only intensity calibration. (The strength of the
2377 intensity has been updated in some cases)
2378
2379 - callisto: add a filter against PIN Diode events when running over
2380 calibration runs since some of the recent calibration runs have
2381 been taken with Pin Diode.
2382
2383 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2384 39943, 44833 in the calibration (MCalibColorSet)
2385
2386 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2387 been set to 1e-18 in callisto_Dec04_Jan05.rc
2388
2389 - callisto: in callisto_Dec04Jan05.rc: set value for
2390 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2391 statistics for the calculation of the mean pulse time
2392 of the cosmisc
2393
2394 - callisto: the charge limit in the calibration has been raised
2395 from 2.5 to 4.5
2396
2397 - callisto: new setup read from callisto.rc
2398 + MCalibCalcFromPast.fNumEventsDump
2399 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2400 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2401
2402 - callisto: MExtractTimeAndChargeSpline extractor:
2403 + The integration ranges were shifted by 0.2 FADC slices to the right.
2404 + unreliable handling of floating point values caused different
2405 results on different platform or with different compiler options:
2406 The new algorithm is numerically exact and more accurate because
2407 it doesn't calculate the integration position by multiple times
2408 adding the step-size (which results in numerical uncertanties
2409 exspecially if multiplied with large numbers)
2410 + A lot of fixes have been introduced which effects integrating the
2411 spline at the edges of the valid range. In this case any memory
2412 was randomly accessed. This behaviour can be tested replacing
2413 all MArrayF by TArrayF which perform a range check (but of course
2414 they are a lot slower)
2415 ! No result obtained with the Spline before can be trusted! Due to
2416 random memory access it might by completely random!
2417
2418 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2419 + extraction range in the high gain to 4.
2420 + weights file to cosmics_weights46.dat
2421
2422 - callisto:
2423 + introduce the check for fluctuating arrival times.
2424 + set charge limit to from 2.5 to 4.5
2425 + introduce asymmetric exclusion due to "deviating number of phes":
2426 Default: -9.0 +4.5
2427 + make deviating number of phes unsuitable (see David's findings).
2428
2429 - callisto: fixed the display of unsuitable pixels. The old change
2430 to a real profile in MHCamera broke it.
2431
2432 - callisto: The cosmics filter is used in MJCalibration now
2433 independant of the pulser color (formaly it was used only for
2434 CT1-pulser data). The threshold of number of max empty pixels
2435 has been raised from 2% to 5% in MJCalibration. The maximum
2436 fraction of rejected event is 50% otherwise the calibration has
2437 failed. The filter now ignores unsuitable pixels.
2438 Setup the filter from callisto.rc using "ContCosmics"
2439 (see MFCosmics::ReadEnv)
2440
2441 - callisto: changed default for fgOffsetFromLogain back
2442 from -2.8 to -1.8 in digital filter.
2443
2444 - callisto: for the common extractors
2445 + MExtractFixedWindow
2446 * MExtractTimeAndChargeSlidingWindow
2447 * MExtractTimeAndChargeSpline
2448 * MExtractTimeAndChargeDigitalFilter
2449 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2450 and fResolutionPerPheLoGain
2451
2452 - callisto: Updated the hi-/lo-gain intercalibration constants
2453 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2454 hilocalib_df6.root
2455
2456 - callisto: The default lo-gain extraction window for the
2457 MExtractTimeAndChargeSlidingWindow extractor has been increased
2458 from 6 to 8 to take the stretch of the pusle into account
2459
2460 - callisto (!!!): fixed an important bug in the setting of the
2461 incoming pedestal pointer to the signal extractor extracting
2462 pedestals. This bug caused the pedestals not to be subtracted
2463 correctly in the calibration afterwards. The effect was about 10%
2464 too high conversion factors for the digital filter and the spline
2465 and more than 40% for the sliding window.
2466 The bug existed since end of February! (Markus G.)
2467
2468 - star: added muon support to star. A new tab "MHMuonPar" is
2469 displayed. The lower right plot is an estimate of the point spread
2470 function. A reference value is displayed. To get the real PSF
2471 you must compare with MC. The setup for the muon analysis
2472 is done in star.rc. More informations can be found in
2473 MHSingleMuon and MHCalibParCalc
2474
2475 - star: The weather data is now displayed in star
2476
2477 - star: MEventRateCalc handles the calculation of the event rate more
2478 accurate now in case of the start of a new run inside a sequence
2479
2480 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2481 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2482 changed only minimally
2483
2484 - ganymed: (MJCut and MJOptimize) now displayes the number of
2485 excess events versus size. The energy estimation is done in
2486 MJSpectrum (sponde)
2487
2488 - ganymed: got support for using other variables than Alpha, eg. Theta.
2489 Therefor you need a class deriving from MHAlpha which supports
2490 this variable (one is already existing: MHTheta, which is now the
2491 default in ganymed). It is setup through ganymed.rc
2492
2493 - added a full featured spectrum program (sponde) which reads
2494 ganymed output and monte carlos and compiles a spectrum
2495
2496
2497
2498 *** Version 0.9.1 (2005/04/14)
2499
2500 - Fix bug on the arrival time reconstruction when using Digital
2501 Filter (in some marginal cases (10%) times were reconstructed shifted
2502 by 0.2 slices)
2503
2504 - all executables now return 2 where in previous versions -1 has
2505 been returned (gave problems with shell-scripts)
2506
2507 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2508 also done with a intercalibration input file
2509
2510 - a bug in the time fine adjustment of the digital filter has been fixed
2511
2512 - a lot of small fixes to calling TPad::Divide with a margin==0
2513
2514 - MStatusDisplay now shows the memory usage
2515
2516 - added a memory leak statistic after the eventloop
2517
2518 - MHadronness replaced by MParameterD
2519
2520 - MEnergyEst replaced by MParameterD
2521
2522 - wobble mode can now be switched on from the data-set
2523
2524 - switched on bad pixel detection for a pedestal level
2525 which is more than 5 times the variance
2526
2527 - Fixed default paths to be correct for the new data center
2528
2529 - Fixed handling of drive data. The pointing position in now
2530 copied to MPointingPos inside star for real and MC events
2531
2532 - made sure, that the sequences in a dataset are sorted by
2533 their number to ensure the correct synchronization
2534
2535 - added all resource files necessary to handle spline extraction
2536 of signal for the late 2004 and the early 2005 data
2537
2538 - update the reference lines for the december data
2539
2540 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2541 This is important for the Dec. and Jan. data where the calibration
2542 pulse position changes much.
2543
2544 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2545 filter. This corrects only an defective extraction of the MC at
2546 low-gain signals lower than 90 phes.
2547
2548 - fixed some slowdown in calibrating data with interleaved events from
2549 Jan and Dec. As a workaround made the pretty palette the default.
2550 The inverse Deep Blue Sea has a bug which slows down long calibration
2551 runs a lot.
2552
2553 - implemented new values from new starguider report as defined
2554 in TDAS00-07 V7.1 (eg SkyBrighness)
2555
2556 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2557 in starguider report (If you merpp the same reports with this version
2558 you'll get the correct units (arcmin) but a different result
2559 than with old versions (wrong units))
2560
2561 - Now the status display can also write PNG, JPEG and XPM (other file
2562 formats are still unsupported by root)
2563
2564 - added a lot of scripts and macros in directory datacenter used
2565 for automatic processing
2566
2567
2568
2569 *** Version 0.9 (2005/03/23)
2570
2571 - Calibration is now done autmatically into photo-electrons like
2572 decided by the Collaboration Board
2573
2574 - Reference lines in the display can be read from resource file
2575
2576 - Interlaced calibration events can be handled by callisto
2577
2578 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2579 and applied in callisto.
2580
2581 - class MJCalibTest can be called by callisto
2582
2583 - callisto can now run with three data types: rawdata, rootdata, MC
2584
2585 - added two classes mreport/MReportStarguider.cc and
2586 mreport/MReportStarguider.h for implementing starguider-data
2587
2588 - the output of merpp-update now contains starguider information:
2589 MReportStarguider and MTimeStarguider
2590
2591 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2592 values were lower than they should. This was more visible for high
2593 energy (Size) events.
2594
2595 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2596
2597 - added a new loop to callisto to support the correct extraction of
2598 the pedestal and pedestal rms through the signal extractor
2599
2600 - added class to perform fourier tranformation of a hexagonal structure
2601 (MHexagonalFT)
2602
2603 - added class to perform fourier tranformation of a hexagonal structure
2604 in a tasklist (MHexagonalFTCalc) example: hft.C
2605
2606 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2607 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2608 small pixels, example: extendcam.C
2609
2610 - added possibility to write data to memory (TTree) using MWriteRootFile
2611
2612 - added possibility to read a TTree stored only in memory by MReadTree
2613
2614 - new classes to deal with the interleaved calibration events:
2615 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2616
2617 - implemented filters to callisto to skip calibration events
2618
2619 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2620 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2621 the slices by statistics
2622 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2623 signal extractor without randomization
2624 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2625 with the signal extractor with randomization (extraction window is
2626 randomly fixed)
2627 The three kind of pedestal is not yet implemented (for speed reasons) as
2628 long as nobody really needs it:
2629 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2630 extracted with the signal extractor with randomization
2631
2632 - callisto now finds the pulse position in the data automatically
2633
2634 - implemented data reduction in calibrated data by reducing the precision
2635 of the stored floating point values (pedestal, rms and signal) to
2636 roughly 0.5%
2637
2638 - fixed showplot to make file format conversion (eg. converting a
2639 status display stored in a root file into a postscript file) in
2640 batch mode possible:
2641 showplot -b --save-as-ps[=outfile.ps] infile.root
2642
2643 - Allow class names as part of filter rules, eg
2644 (MFSupercuts) && (MHillas.fSize>100)
2645
2646 - fixed a lot of stuff to allow all programs to process MonteCarlo
2647 camera files.
2648
2649 - enhanced possibility to debug reading of resource file
2650
2651 - MDataChain should handle priorities of operator more
2652 accurate now
2653
2654 - completely revised the container in which the signal is stored
2655 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2656 * the new implementation is faster and
2657 * needs less storage space
2658
2659 - FIRST version which can process Monte Carlos through the
2660 whole chain of programs (callisto, star, etc)
2661
2662 - implemented new image parameters for the border length of
2663 the shower image (MNewImagePar2)
2664
2665 - implemented wobble-mode in ganymed
2666
2667 - new class (MJOptimize) taking care of all optimization processes
2668
2669
2670
2671 *** Version 0.8.6 (2004/10/05)
2672
2673 - New combined signal and time extractor
2674 MExtractTimeAndChargeDigitalFilter
2675
2676 - The Report for the trigger section in the CC run summary has been
2677 updated, and now the IPRs (Individual Pixel Rates) are available.
2678
2679 - new macros for database interaction: filldotrun.C, filldotrbk.C
2680
2681 - added new program which can convert colored output which was redirected
2682 into a file back into colored text (for example to display it with
2683 more): showlog
2684
2685 - added new program to display an MStatusArray of plots (stored with
2686 MStatusDisplay) from a file: showplot
2687
2688 - Added support for Sequences (MSequence). Sequences are blocks of run
2689 files containing the same calibration and belonging to the same
2690 source
2691
2692 - Added a new task (MTaskEnv) which can be used in setup files to switch
2693 between different tasks (for example to choose a signal extractor)
2694
2695 - Implemented automatic file splitting in MWriteRootFile
2696
2697 - After image cleaning an island index is assigned to all used pixels.
2698 The index corresponds to the order of the islands in size.
2699
2700 - added a cleaning which takes signal height _and_ arrival time into
2701 account: probability cleaning (for more details see MImgCleanStd)
2702
2703 - added a cleaning which takes takes the absolute number of photons
2704 times the area ratio as cleaning level
2705 (for more details see MImgCleanStd)
2706
2707 - Changed calculation of image parameters such, that it can be done
2708 for all used pixels or the pixels with a defined island index only
2709
2710 - implemented new image parameters displaying the number of islands,
2711 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2712
2713 - event display in executable changed to support also calibrated files
2714 (done with MJCalibrateSignal)
2715
2716 - added program doing the calibration and the signal extraction
2717 and signal calibration: callisto Most part of the setup is done
2718 by a resource file: callisto.rc
2719
2720 - implemented support for pixels with negative IDs (Raw file format
2721 version 4)
2722
2723 - implemented an new option in merpp (--auto-time) to get the time
2724 range for cc and/or caco data from the run header of the raw data
2725
2726 - New star-program (star and MJStar). Taking calibrated data from
2727 callisto/MJCalibrateSignal as input. The setup is done through
2728 a resource file: star.rc
2729
2730 - Added possibility to setup the eventloop in the mars-executable
2731 Camera Display by a resource file: mars.rc
2732
2733 - The the mars-executable Camera Display can now also read
2734 calibrated data files written by callisto/MJCalibrateSignal
2735
2736 - Added a new class which can calculate the source position in
2737 the camera from a pointing model known to be correct and
2738 the pointing model used for observations (MSrcPosFromModel)
2739
2740 - added a new version of the class calculating the effective on-time
2741 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2742 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2743 MHTimeDiffTheta.
2744
2745 - added the possibility to count how often a signal is above (or
2746 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2747 can replace MHTriggerLvl0)
2748
2749 - added ore convinient ways to set the axis-titles of your histograms
2750 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2751 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2752
2753
2754
2755 *** Version 0.8.5 (2004/08/06)
2756
2757 - new Signal Extractors: MExtractFixedWindowSpline
2758 and MExtractAmplitudeSpline
2759
2760 - implementes interleave in merpp to be able to merpp parts of a file
2761
2762 - implemented force-functionality to merpp
2763
2764 - star display to display star catalogs (MAstroCatalog)
2765
2766 - star display to 'mirror' stars to the camera (MAstroCamera)
2767
2768 - implemented a new cleaning option which allows cleaning scaled with
2769 the real ratio of the rms depending on the pixel size, not only the
2770 square root of the pixelsize (MImgCleanStd, MCameraData)
2771
2772 - removed obsolete MBlind* classes
2773
2774 - Signal extractor taking the AB flag into account implemented (this makes
2775 an odd number of slices for signal extraction possible
2776 (MExtractSignalABcorr)
2777
2778 - implemented a class extracting the pedestal from the raw-data (events)
2779 itself using empty lo-gain (MpedCalcFromLoGain)
2780
2781 - Added mean values to MPedPhotCam
2782
2783 - Added Makefile for Darwin (this OS is NOT officially supported!)
2784
2785
2786
2787 *** Version 0.8.4 (2004/04/19)
2788
2789 - new fast arrival time extractor using cubic splines:
2790 MExtractTimeFastSpline
2791
2792 - implementes multi-argument support in MDataChain
2793 ("pow(a, b)")
2794
2795 - implemented double reference support in MDataChain
2796 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2797
2798 - added support in MF for expressiond like
2799 "MHillas.fWidth<2*<MHillas.fLength"
2800
2801 - MDataChain is now able to support variables like [0], [1], ...
2802 which can be used in fit functions as parameters. The interface
2803 is implemented through the new virtual function
2804 MParContainer::SetVariables
2805
2806 - added new class MArrivalTimeCam/MArrivalTimePix:
2807 Storage containers to hold the ArrivalTime of the camera/pixel
2808
2809 - added new classes for the calibration of relative arrival times:
2810 MCalibrationRelTimePix and MCalibrationRelTimeCam
2811
2812 - added new classes to extract the signal of the blind pixel and the
2813 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2814
2815 - added new classes for the bad-pixels treatment (MBadPixels*)
2816 which are more powerfull than the old ones (MBlindPixel*)
2817 and will replace them.
2818
2819 - added filter against cosmics: MFCosmics
2820
2821 - added new class MArrivalTimeCalc2:
2822 Calculates the arrival time as the signal weighted mean of the time
2823 slices in the maximum window
2824
2825 - added a new macro call pointspreadfucntion.C that fits with a 2D
2826 gaussian the DC spot for an star. It gives you the RMS of
2827 the PSF and the center of the star, very useful for misspointing
2828 studies.
2829
2830 - added support for multi-telescope camera files. Added classes
2831 MStereoCalc and MStereoPar, classes to calculate and store shower
2832 parameters calculated from the data of two telescopes, for the MC
2833 studies regarding the MAGIC clone.
2834
2835 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2836 MC data calibrated in photons instead of ADC counts.
2837
2838 - added three macros to show the calibration and analysis chain of
2839 MC data. The macro starmc.C does both calibration and analysis, producing
2840 an output containing Hillas parameters for each event. The macro
2841 mccalibrate.C does just the calibration and writes out a file containing
2842 pixel information in photons instead of FADC data. The macro starmc2.C
2843 reads in such a file and produces an output with Hillas parameters.
2844
2845 - added MPedPhotCalc to compute pedestals in units of photons, see
2846 macro pedphotcalc.C
2847
2848 - added all class to perform the calibration, see macro calibration.C
2849
2850 - added class MFFT to perform Fast Fourier Transforms
2851
2852 - added class MSimulatedAnnealing to perform simulated annealing
2853 minimizations
2854
2855 - added new macro bootcampstandardanalysis.C which holds the skeleton
2856 of the analysis chain discussed in the december bootcamp.
2857
2858 - added support for DAQ raw data file format V2
2859
2860 - implemented an arbitrary time stamp for the events from raw-data
2861 files with file version<3. It is calculated from the run number,
2862 the date of start and the FADC clock tick from the first module
2863
2864 - implemented the correct decoding of the event time-stamp
2865 coming from the DAQ for raw-data files with file-version>2
2866
2867 - added a new classes storing the pedestals in units of photons:
2868 MPedPhotPix, MPedPhotCam
2869
2870 - added support for DC current files from the camera control
2871
2872 - added support for start- and stop-time when merpping report files
2873
2874 - added MReportCC storing the weather data from the CC-REPORT
2875
2876 - added class to fill trainings and test matrices (MTFillMatrix)
2877
2878 - added a filter performing a software trigger (MFSoftwareTrigger)
2879
2880 - Added classes to perform parts of the standard analysis (Jobs):
2881 + MJPedestals
2882 + MJCalibration
2883 + MJExtractSignal
2884 Note: All of them are preliminary!
2885
2886 - Added Iterator to iterate over files giving only the run-number
2887
2888 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2889 the evolution of a sector vs time
2890
2891
2892
2893 *** Version 0.8.3 (2003/12/05)
2894
2895 - adapted Random Forest classes to allow the use with MC
2896 multi-telescope files which can be produced with the coming
2897 camera version 0.7.
2898
2899 - added classes to read and interprete central control report files
2900 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2901
2902 - enhanced merpp (the executable) to support .raw and .rep files.
2903
2904 - added classes for light calibration (MCalibration* and
2905 MHCalibration*) by Markus Gaug. Further work has to be and will
2906 be done soon.
2907
2908 - Added a preliminary 'synchronizer' (MReadReports) which will
2909 replace MReadMarsFile as soon as it is finished.
2910
2911 - Added a tutorial macro demonstrating how report files are merpped
2912 and how they can be read from the root file in the correct order
2913 of time (readrep.C)
2914
2915 - Added a generalized histogram (similar to MH3) called MVsTime
2916 which allows to plot variables (or rules - MDataChain - of
2917 variables) vs time. For an example have a look at tempvstime.C.
2918
2919 - Changed the name of the event trees:
2920 + Events --> Events
2921 + PedEvents --> Pedestals
2922 + CalEvents --> Calibration
2923
2924 - changed name of MTime in the event trees from MRawEvtTime to MTime
2925
2926 - added displaying the sector indices to the mars event display
2927
2928 - Magic Online Analysis (MOnA) implemented in a first version
2929 (see mona.cc, MOnlineDump and MOnlineDisplay)
2930
2931 - added classes to calculate event rate
2932 (preliminary: MEventRateCalc, MEventRate)
2933
2934 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2935
2936 - added classes dealing with the telescope pointing position (MPointing*)
2937
2938 - implemented the 'final' Mars time stamp based on some experiences with
2939 the new 'Synchonizer'
2940
2941
2942
2943 *** Version 0.8.2 (2003/11/10)
2944
2945 - accelerated standard analysis by a factor of 6-8 ...
2946 + doing precalculations in MGeomCam for the pixel area ratio
2947 + creating a look up table for the single pixels in MCerPhotEvt
2948
2949 - added task to calculates weights in case you want to 'change'
2950 the energy spectrum of a monte carlo file
2951 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2952
2953 - added a new executable star which implements the
2954 star.C macro as precompiled executable. Currently a flexible
2955 setup is not possible, but a 'input card' setup will follow.
2956
2957 - Starting to implement Multi-Telescope-Support based on the
2958 upcomming camera version 0.7. The base for a general support
2959 is implemented and the star-functionality is proven to work.
2960
2961 - Replaced Event-Display in and Camera-Display in the Mars GUI
2962 executable by a more convinient display base on MStatusDisplay.
2963
2964 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2965
2966
2967
2968 *** Version 0.8.1 (2003/10/20)
2969
2970 - added signal subtraction for pure on data by means of fitting
2971 the background in the off region or by performing a combined
2972 signal/background fit. Provides necessary histograms for
2973 obtaining energy spectra and a light curve.
2974
2975 - added classes to perform and study the selection of the
2976 2nd Level Trigger on MC data (example in triglvl2.C macro)
2977
2978 - added pedestal calculation
2979
2980 - implemented "democratic cleaning" (tail cut value proportional
2981 to pixel area) according to Wolfgang's suggestion.
2982
2983 - added Sigmabar treatment (calculation and basic histogramming)
2984
2985 - added basic routines to apply padding
2986
2987 - added first implementation of MARS-based source visibility plotter
2988 (needs to be linked against slalib, preliminary version)
2989
2990 - enhanced functionality of data chains: random numbers, conversion
2991 functions and access to MHMatrix objects
2992
2993 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2994 numbers under certain circumstances (runs with 0 events included)
2995
2996 - fixed a bug in the general filter MF (didn't work on some systems
2997 at all)
2998
2999 - fixed a bug in chaining files, which caused the analysis to crash or
3000 ignore files
3001
3002 - implemented more geometry classes describing the parameters used
3003 to simulate the PMT camera
3004
3005 - added new Monte Carlo classes containing the setup of the different
3006 programs in the MC chain.
3007
3008 - added a (preliminary) general task to evaluate chi-square of a given
3009 parameter in an eventloop.
3010
3011 - first implementation of a container describing the observatory
3012 location (Long, Lat, etc)
3013
3014 - added Random Forest - method for g/h-separation
3015
3016 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3017 (this means, that it is compiling, but not yet fully tested)
3018
3019 - added a new status display which can show the present status
3020 of histograms while an eventloop is running (MStatusDisplay,
3021 an example can be found at status.C)
3022
3023 - reorganized directories:
3024 classes describing the image --> mimage
3025 classes containing Monte Carlo Histograms --> mhistmc
3026 classes for Random Forest method --> mranforest
3027
3028 - added (event-)weights to fill histograms
3029
3030 - colors in logging output to screen
3031
3032 - changes to the Image Parameter declaration:
3033 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3034 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3035 + MHillasExt now derives from MParContainer instead of MHillas
3036 --> Files written with the old definition are more or less unreadable
3037
3038 - reading of reflector files
3039
3040 - display data from reflector files in the camera
3041
3042 - implemented currents (and display them in the camera)
3043
3044 - logarithmic scale in camera
3045
3046 - added class to iterate through directory contents (MDirIter)
3047
3048
3049
3050 *** Version 0.8 (2002/11/18)
3051
3052 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3053
3054 - corrected 48(!) wrong entries in the Next Neighbor table of the
3055 Magic Camera (all in the inner part of the outer ring, mostly
3056 missing a single NN)
3057
3058 - Fixed a bug in the table describing the Next Neighbours of the
3059 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3060 have any neighbour)
3061
3062 - changed trigrate.C: now it calculates the pure NSB triggers from
3063 a camera file (generated with no showers), so there is no need
3064 to introduce them by hand in the BgR array (for more details
3065 please ask Abelardo)
3066
3067 - added MHHadronness (and MHadronness) as a general facility to evaluate
3068 the quality of a gamma-hadron seperation method
3069
3070 - changed MWriteAsciiFile to accept rules (MDataChain)
3071
3072 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3073 must be replaced by calles to MWriteAsciiFile::AddColumn and
3074 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3075 changed.
3076
3077 - Implemented generalized event-matrices (one row per event)
3078 (MHMatrix)
3079
3080 - implemented the one dimensional composite probabilities
3081 (MHCompProb, MCompProbCalc, comprob.C)
3082
3083 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3084 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3085
3086 - Added a camera display displaying the pixel numbers to the
3087 event display gui.
3088
3089 - Added Monte Carlo Informations to event display gui
3090
3091 - Changed the camera display to display the pixel numbering
3092
3093 - Added three buttons to the camera display to change the palette
3094
3095 - Added the number of used and core pixels after image cleaning
3096 to MHillas
3097
3098 - Changed the algorithm used in MHillas according to TDAS 02-03
3099
3100 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3101
3102 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3103
3104 - Added fCosDeltaAlpha to MHillasSrc
3105
3106 - The numbers of photons used to calculate fConc and fConc1 in
3107 MHillasExt are now scaled with the pixel size, so that one get
3108 a four times smaller value for the bigger pixels in the outer ring.
3109
3110 - added new task to smooth the camera contents (MCameraSmooth)
3111
3112 - added possibility to use interpolated pixel values for blind pixels
3113 instead of removing it completely from the analysis
3114
3115 - Implemented the possibility to save the whole eventloop with
3116 its setup to a file. This information can be read and from
3117 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3118 and MEvtLoop::MakeMacro. If you find something not working, please
3119 report - this stuff is still in a beta phase.
3120
3121 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3122 file having crab starfield, but also for all following files - fixed
3123
3124 - MTaskList::PrintStatistics can now be instructud to print also the
3125 title, too: use PrintStatistics(0, kTRUE)
3126
3127 - Changed the image cleaning so that pixels with to many 'used'
3128 neighbors are left used (to get rid of 'holes' in events)
3129
3130 - Introduced more output to the camera displays
3131
3132 - Added an array of histograms (eg one hist per run), MHArray
3133
3134 - Added a _preliminary_ version of the reader for CT1 PreProc files
3135 (MCT1ReadPreProc)
3136
3137 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3138 (thanks to Raquel)
3139
3140 - added the first energy estimator (MEnergyEstParam, estimate.C,
3141 estfit.C) using a parametrization
3142
3143 - Added some new Monte Carlo paremeter containers used to store
3144 setup information from the MC chain (MMcConfigRunHeader,
3145 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3146
3147
3148
3149 *** Version 0.7 (2002/04/30)
3150
3151 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3152 the pedestal mean value was saved incorrectly. For files from
3153 this versions we substract 0.5 from the pedestal mean.
3154 WARNING: This may effect your results, so don't wonder...
3155
3156 - First implementation of an algorithm using only triggered events
3157 for the collection area calculation
3158
3159 - Ascii Output can now also be used for parameter containers which
3160 doesn't overload MParCointainer::AsciiWrite
3161
3162 - The Ascii Output is now also capable of writing single data members
3163 of one container
3164
3165 - You are now able to change the order of the values written to the
3166 ascii file
3167
3168 - You can now specify a conversion factor for each data member written
3169 to an ascii file. This may be usefull to change the units of the
3170 data member (eg. degrees instead of millimeters in case of the
3171 hillas parameters)
3172
3173 - Replaced old MHillas by a new structure which allows you to extend
3174 the parameters stored in MHillas very easily:
3175 see MHillas and MHillasExt
3176
3177 - Added classes to handle source dependancy of image parameters:
3178 see MHillasSrc
3179
3180 - Added container (MBinning) to have a standard input for the binning
3181 in different histograms (eg. the Energy bins should be the same in
3182 all histograms)
3183
3184 - Changed Hillas histograms from mm to deg
3185
3186 - Added the flexible binning to the hillas histograms
3187
3188 - Added a filter for the alpha parameter (MFAlpha)
3189
3190 - It is now possible to write single data members of a class object to
3191 an output stream instead of the whole container only
3192
3193 - Added a generalized filter for a data member:
3194 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3195
3196 - Added a generalized Filter parser for more difficult filter rules
3197 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3198
3199 - Added new Monte Carlo histograms:
3200 MHMcEnergyImpact and MHMcEfficiency
3201
3202 - Added many new histograms needed for the flux calculation.
3203
3204 - Added a generalized histograms which can fill and show up to three
3205 data members in either a one-, two- or three-dimensional histogram, eg:
3206 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3207
3208 - Added:
3209 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3210 * calculation of <Theta> as a function of time (MHThetabarTime)
3211 they are needed in the flux calculation in
3212 order to select for a given bin in Theta (or time) the appropriate
3213 effective collection area, which is assumed to be given as a function
3214 of Theta and the true energy
3215
3216 - Added calculation of the migration matrix in the energy
3217 (MHMcEnergyMigration):
3218 the migration matrix describes the migration from the true (E_true)
3219 to the estimated energy (E_est); it is needed to determine the
3220 distribution of E_true from the measured distribution of E_est
3221 by unfolding
3222
3223 - changed the color palette in the camera display to DeapSea.
3224
3225
3226
3227 *** Version 0.6 (2002/01/15)
3228
3229 - Introduce the option of disable pixels (MBlindPixels and
3230 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3231 able to deal with Star Field NSB.
3232
3233 - Fixed a bug in the pedestals substraction
3234
3235 - Introduced verbosity levels
3236
3237 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3238
3239 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3240 work correctly (thanks to Abelardo)
3241
3242 - Introduced correct treatment of the diffuse Night Sky Background
3243 and NSB (MMcPedestalNSB)
3244
3245 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3246
3247 - Introduced MMcRunHeaders which contains monte carlo run informations
3248
3249 - Added a 'Print'-Task (MPrint) which calls the Print function
3250 of a parameter container for each event
3251
3252 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3253
3254 - changes to be more efficient with root 3.02/06
3255
3256 - root 3.02/06 fixes:
3257 + the memory leak when reading MRawEvtData
3258 + loosing more time than necessary to update the progress bar
3259
3260 - MWriteAsciiFile is now capable of writing more than one container
3261 in a line. For example: To be able to write Monte Carlo and
3262 Hillas values (energy and alpha) in one line.
3263
3264
3265
3266 *** Version 0.5 (2001/11/06)
3267
3268 - Added new GUI functionality (Analysis)
3269
3270 - Added a camera display to be able to display events in the camera
3271 together with the calculated hillas ellipse
3272
3273 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3274 object at any state of the analysis, so that the output are several
3275 states
3276
3277 - Fixed a bug in the collection area error calculation
3278 (Thanks to Ciro and Abelardo)
3279
3280 - Fixed a bug which causes merpp to crash in some environments
3281
3282 - Implemented auto enabling scheme for Branches to speed up reading
3283 a lot (see MReadTree and MTask)
3284
3285 - Fixed a bug in the Histogram classes which caused histograms to
3286 be written to a file by MWriteRootFile without request
3287
3288 - changed the object I/O from the old stylish root I/O to the new
3289 'auto evolution scheme' This was done only for classes which are not
3290 yet used in Monte Carlo files, so that these files are still readable.
3291
3292 - Added support for a progress bar in MEvtLoop and MReadTree
3293 (see the Analysis Window in Mars for an example)
3294
3295 - Fixed a bug in the package creation which disturbed the conversion
3296 between a mars version unpacked from a tar file and the repository.
3297
3298 - Changed the code to writer merpped (converted into root format)
3299 raw files, to get faster (around 10%)
3300
3301
3302
3303 *** Version 0.4 (2001/09/20)
3304
3305 - This release is made to compile on a root version >= 3.00
3306
3307 - Fixed a bug which causes MReadTree to read the first file only
3308
3309 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3310
3311 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3312
3313 - Added a task to write several container to a root file (MWriteRootFile)
3314
3315 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3316
3317 - Added calculation of the collection area (MMcCollectionAreaCalc)
3318
3319 - fixed some bugs in the Hillas calculation
3320
3321 - added filters to be able to control the task execution dependent on
3322 a parameter (for example: the number of level 1 triggers in a MC-file)
3323
3324
3325
3326 *** Version 0.3 (2001/04/23)
3327
3328 - Many demo macros added
3329
3330 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3331
3332 - Hillas Calculation added
3333
3334 - Standard image cleaning available
3335
3336 - MReadTree is now able to handle more than one file
3337 (Remark: of the same structure)
3338
3339 - Now we are able to display events in a first version of the
3340 Camera event display. To do this we must run the macro
3341 "macros/readCT1.C" to read data from CT1.
3342
3343
3344
3345 *** Version 0.2 (2001/01/24)
3346
3347 - First Implementation of a Gui to read the raw data. Start the
3348 gui with the command mars.
3349
3350
3351
3352 *** Version 0.1 (2000/12/20)
3353
3354 - First official release 0.1
3355
3356 - Changes:
3357
3358 + changed calling style of MRawPixelIterator from do...while to
3359 while-loop
Note: See TracBrowser for help on using the repository browser.