source: trunk/MagicSoft/Mars/NEWS@ 9565

Last change on this file since 9565 was 9565, checked in by tbretz, 15 years ago
*** empty log message ***
File size: 136.9 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * On some systems (version of make?) the __LINUX__ definition was not set
8 when compiling. This lead to MTime(-1) not working properly. Fixed.
9
10 ;ceres:
11
12 * Allow for individual mirrors with parabolic shape (for details see
13 MReflector::ReadFile)
14
15
16
17== Version 2.4 (2009/12/23) ==
18
19 ;general:
20
21 * Added a new palette "temp" to MH::SetPalette which should resample
22 a temperature
23
24 * Added consistency check for two consecutive runs
25
26 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
27 has been disconnected and the L1 (L1TPU) has directly been connected
28 to another bit in the trigger pattern. This has been fixed by an
29 update of the decoding. Both bits are now or'ed together.
30
31 * Added a new camera layout MGeomCamFact which is the "four rectangular
32 pixels ordered in a hexagonal geometry" layout
33
34 * All programs now store the command line as TNamed "CommandLine"
35
36 * the environment variable OSTYPE should now be obsolete. Instead
37 the output of "uname -s" converted to lower cases is used
38
39 * The Makefiles should now detect the OSTYPE automatically using
40 uname. This should make the setting of OSTYPE obsolete
41
42 ;showplot:
43
44 * If a file without a MStatusArray is opened all object (not just
45 canvases) found in the file are drawn. Note that this may result
46 in empty tabs.
47
48 ;ceres:
49
50 * The night sky noise is now scaled with the sensitive area and
51 is given in units per square centimeter
52
53 * The night-sky noise now also takes the cones transmission
54 into account
55
56 * The night sky noise can now be calculated from a night-sky
57 spctrum
58
59 * A transmission curve for the cones can now be given
60
61 * Added the possibility to add a cut after the image parameter
62 calculation (''Cut'')
63
64 * updated the PDE of the GAPDs with a more reliable curve from
65 the meeting page (linear extrapolate below 350nm)
66
67 * The impact distribution in the event distrbutions is now
68 perpendicular to Alt/Az and the histogram is displayed in 1D
69
70 * The GAPD PDE has been updated
71
72 * PDEs and mirror reflectivities have been linearily extrapolated
73 to match the wavelegth range between 290nm and 900nm
74
75 * There is no default pulse shape anymoe it must be given in
76 the resource file
77
78 * Fixed a bug which caused the aerosol coefficient to be incorrectly
79 initialized. The effect might be random but seems to be small.
80
81 * Now accepts sequence files as input
82
83 * creation of pedestal and calibration files is now steered by
84 --mode (see ceres help)
85
86 * Instead of initializing the whole G-APD chip (all cells) before
87 each event (which is rather time consuming) a time evolution before
88 each event is now simulated which is enough to recovere every cell
89 to 99.999% of its response taking the background rate into account.
90 This is in total about a factor of ten faster and should not be
91 less accurate because under normal conditions the recovering cells
92 and the newly hitten cells will hardly be identical (due to
93 statistical reasons)
94
95 * improved the trigger algorithm which is now faster and allows easily
96 for multiplicity triggers
97
98 * The PDC flag in the file name is now correctly written
99
100 * A "PreCut" has been added which can be used after reading the events
101 to select them even before any calculation is done.
102
103 ;merpp:
104
105 * The new drive reports which contain also the status of the starguider
106 are now implemented, but the starting date (17/05/09) is preliminary.
107
108 ;callisto:
109
110 * Fixed a bug which prevented MAGIC Monte Carlo file from being
111 calibrated (ceres files worked)
112
113 * updated (Muon) calibration constants of period 62, 63, 72-75
114
115 ;star:
116
117 * allow to run thru even if discriminator threshold are missing
118 (they are not used for analysis so far anyway)
119
120 ;ganymed:
121
122 * added new starguider calibration for sequences since 1000534
123
124 ;database:
125
126 * added possiblity to query/plot data from certain source (with
127 regular expressions) in plotdb.php
128
129 * new feature in showplots*.php: on mouse-over additional information
130 on the sequence is displayed
131
132 * tables on database website have also 'Last' link now
133
134 * new version of builddatasets.php with more comfortable sequence
135 selection
136
137 * new features in builddatasets.php:
138 - user management
139 - 'Get Data Set File' button
140 - 'Display Selected Sequences' button
141 - 'Display Not Selected Sequences' button
142 - 'Select all' buttons
143
144 * builddatasets.php: added possibility to update data sets in the
145 database
146
147 * added limit for cloudiness for sequences in the tab 'Limits'
148
149 ;automation:
150
151 * jobmanager can be used more flexible now: via environnent variable
152 $AUTOMATIONSETUP more than one jobmanager per user can be started
153 using the same MARS version
154 Usage: export AUTOMATIONSETUP=mysetup ; /fullpath/jobmanager
155 and provide a file Mars/datacenter/scripts/setup.mysetup
156
157
158
159== Version 2.3 (2009/03/07) ==
160
161 ;SUGGESTION
162
163 * There is no need to re-run any data because no change took place which
164 could have an effect on the output. However, if you want a
165 meaningful SrcPos plot for your MCs in sponde you must re-process
166 star for your MCs first.
167
168 ;REMARK
169
170 * File produced with this release containing a camera geometry (which
171 are basically all files were produced as default) will not be readable
172 by older releases.
173
174 ;general
175
176 * fixed a few small bugs which could cause the display to crash in ganymed
177 and sponde
178
179 * in sequence file the date can now be omittet. In this case the
180 leading date with the underscore is missing in the expected filename
181
182 * the geometry class now also supports other geometries than just hexagons
183
184 ;automation
185
186 * added magnetic field Azimuth direction (ARRANG), currently
187 at ~ -7deg at La Palma
188
189 ;database
190
191 * plotdb.php: added default (sequences) for startup, added possibility
192 to set size of plot
193
194 * added a new table ''RunDataCheck'' which containes the rates after
195 image cleaning for every run which succeeded star. It can be
196 plotted using ''plotrundb.C''
197
198 ;merpp
199
200 * added support for Arehucas Version >= 200812140
201
202 * added support for Arehucas Version >= 200809030
203
204 ;mars
205
206 * The display now also displays the trigger pattern
207
208 * The display can now display ceres reflector (_R_) files
209
210 ;ceres
211
212 * added a uniformly distributed one-bin time jitter for the start of the
213 digitization. Otherwise the first photon would be digitized always with
214 the same alignment to the bins
215
216 * Added a plot showing the production height of the photons
217
218 * Moved the particle id from the event header to the run header
219
220 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
221
222 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
223
224 * Added many new options to control the tasks. For deatils see ''ceres.rc''
225
226 * Removed obsolete plots in pedestal and calibration mode
227
228 * Removed the non-NightSky photons from the plots where they are just
229 disturbing
230
231 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
232
233 * The daq event number now represents the readout number
234
235 * The camera ''electronics'' can now be ''switched off''
236
237 * A new tab ''Info'' now display basic things like the reflector
238 layout
239
240 * Improved reading speed for corsika files
241
242 * Improved memory handling (if a large ampount of memory was needed
243 for a single event all further events were stored in the same
244 memory and it was never freed, so the program took this memory
245 until the end)
246
247 * Converted the code from MMCS' reflector program to MSimAtmosphere
248 (instead of the tables build in for MAGIC Winter and Summer
249 atmosphere we use the values written by Corsika fitted to the
250 tabulated atmosphere given as input)
251
252 * For caluclating the displayed image parameters in ceres a basic
253 image cleaning removing isolated pixels is now done.
254
255 * The magnetic field direction (ARRANG) is now taken into account
256
257 * Added plot for the energy threshold after trigger ''Threshold''
258
259 * Added plot for the effective collection area after trigger ''TrigArea''
260
261 ;star
262
263 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
264
265 * The definition of fConcCore has slightly changed. The numbers
266 might decrease a little bit (the effect should be rather small)
267
268 ;ganymed
269
270 * added pointing model 328198
271
272 ;sponde
273
274 * The SrcPos plot for your MCs was so far meaningless because it just
275 displayes the MSrcPosCam data from the input star-files. Unfortunately,
276 this containes was never written to the star-files yet.
277
278 * A new Tab 'OnTime' is available which is an effective on-time
279 fit as in star but for all data. This is mainly for manual cross-check
280 of the effective on-time
281
282 * In some circumstances it might be necessary to re-calculate the
283 eff. on-time from the fit in the new tab, e.g. when a zenith distance
284 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
285
286 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
287 it to its own output file (for convinience)
288
289
290
291== Version 2.2 (2009/01/30) ==
292
293 ;SUGGESTION
294
295 * This release doesn't contain a major change which is expected to
296 change your results. Nevertheless there are small changes to
297 the calibration which can effect at least the first few hundred
298 events in any (mainly MUX and even more SUM) sequence a little bit.
299 So it is recommended although not necessary to reset your sequences
300 in the database before further processing.
301
302 ;NEW
303
304 * A first implementation of a Monte Carlo simulation program
305 (ceres - Camera Electronics and REflector Simulation) has been
306 implemented. It can simulate a full telescope already including
307 a complete reflector simulation and a flexible trigger and readout
308 simulation. Currently, no perfect setup is implemented and
309 especially the output of the program (data structure) should
310 be considered alpha state. Also the user interface is not yet
311 ready.
312
313 ;general
314
315 * All command line options after -- are now interpreted as
316 arguments (usually everything which doesn't start with a minus)
317 rather than options (usually everything which starts with a
318 minus). This allows to use file names starting with a -
319
320 * In all resource files you can now initialize the random number
321 generator. For details see: MJob::InitRandomNumberGenerator
322
323 * added a new program called ''readcorsika''. It's purpose is (in analogy
324 to readraw and readdaq) to read a Corsika output file (for now
325 only cherenkov output is supported) and print its contents in a
326 human readable form. It can also write the contents of this file
327 into a root-file.
328
329 * The calculation of the maximum distance to the origin in a MGeomCam
330 has been improved (edges might be further away than the sides).
331 This is just a tiny change but it might change the appearance of
332 the radial profiles a little bit.
333
334 * The default binning of the center-of-gravity plot has slightly been
335 increased
336
337 ;Database
338
339 * Added informations about the DC currents (fMinCurrents, fMedCurrents
340 and fMaxCurrents). The values are retrieved from the plots showing
341 the average DC currents of all pixels versus time.
342
343 * Websites with tables have now the opportunity to remove lines
344 ('-' button at beginning of each line) and get all lines back
345 ('+' at top of the column)
346
347 * Websites: added option to query only sequences containing sumtrigger
348 events
349
350 * Websites: added option to group by date (year, month, night) for runs
351 and sequences and enabled that combining of different group-bys,
352 e.g. status, date and source is possible
353
354 ;automatic analyis
355
356 * Rewritten producing plots in the web.
357 New plots, namely the output of plotoptical.C (extinction curve from
358 KVA), plotstat.C (status of the automatic analysis (percentage of
359 processed, analysed data etc.)) and plotusage.C (statistics of the
360 condor usage in the data center) has been are available now next to the
361 plots of plotdb.C
362 Mean values from the plots (output of the macro) are provided in a
363 txt file now.
364 The creation of the plots for callisto, star and ganymed in the web is
365 now steered via database. Consequently the plots are faster and
366 reliable up-to-date.
367 For all plots, a new layout is available facilitating the browsing
368 through the plots and providing additional information on the
369 displayed values. (tabs.php) These plots are linked from the DB
370 websites and the wiki.
371
372 ;statusdisplay
373
374 * The ''Loop'' entry in the menu bar now contains an option to pause
375 the loop and to process single events.
376
377 ;merpp
378
379 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
380 instead of RunHeaders)
381
382 * Now allows to merpp files newer than 2008/09/03.
383
384 * Added fixes for wrong (wrong or double) run- and file-numbers
385 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
386
387 ;callisto
388
389 * Extracting the pulse position for the pulse position check events
390 with sum trigger were denied. This decreased the statistics
391 extremely and therefor the resulting puse position was calculated
392 quite weak. Now sum events pass the calculation if and only if they
393 have also a level 1 trigger.
394
395 * the extraction of pedestal events and pulse position from the
396 first data events is now more automatic and makes sure that
397 a more precise number of events is extracted independent of
398 the ratio with which pedestal events or events with signals
399 are contained in the data.
400
401 * Updated Muon calibration constants for all MUX data (teh changes were
402 all smaller than 5%)
403
404 ;star
405
406 * For the calculation of the effective on time all sum-triggered events
407 were skipped. Now all Level1-triggeres events will pass. This might
408 result in a slight inaccuracy of the effective on time.
409
410 ;ganymed
411
412 * If the source position is more than 1deg away from the camera
413 center an error is raised now.
414
415 * Hopefully fixed the bug ''ganymed crashes when resized''
416
417 ;sponde
418
419 * Fixed a problem which causes the fitted spectral slope to be displayed
420 incorrectly. If you use MJSpectrum::FormFlux in your macros make
421 sure that the parameter 0 of your fit is negative.
422
423 * Added a histogram showing the read source position of your MCs
424
425
426
427== Version 2.1.1 (2008/08/04) ==
428
429 ;Database
430
431 * Added the median number of photo electrons from the calibration
432 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
433 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
434
435 * Added fTotOnTime, which is the on-time as given by the run-headers
436 (in contradiction to fAbsOnTime which comes from CC)
437
438 * Added new primaries for the new data structure (Magic II): for the
439 tables dealing with sequences (SequenceBuild Status, Sequences,
440 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
441 this is the telescope number (fTelescopeNumber) for the tables dealing
442 with runs (RunData and RunProcessStatus) this is in addition the file
443 number (fFileNumber)
444
445 * Added column fPriority to the status tables to be able to steer the order
446 in which the data is processed. As default the run, sequence and dataset
447 number are used.
448
449 ;automatic analyis
450
451 * Adapted scripts to the new data structure: They can handle now different
452 telescopes (getting the information as usual from the database).
453 The paths for Magic 2 are not yet implemented.
454
455 ;general
456
457 * should work now with root 5.20/00 (please note that root 5.20/00
458 we encounter crahses in the status display which are ot yet
459 understood)
460
461 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
462 instead of the base name of the file. This makes them easier to
463 access from the code
464
465 * Default Monte Carlo names in MSequence do not require the _E at
466 the end anymore
467
468 * where abrrevating a sequence file with a sequence number is possible
469 also "telescope:sequence" is now accepted, e.g.:
470 star 2:2000123 --out=output
471 see the programs' help for more details.
472
473 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
474 from the database. See the constructors for more details.
475
476 * MReadTree now supports friends
477
478 * MReadTree can now read also files not written by MARS and store
479 the data encapsulated in emulated MParContainers
480
481 * added a new starguider calibration valid since 15.1.08
482
483 ;showplot
484
485 * showplot can now read more than one file at once. This is especially
486 inetersting if reading files containing pure canvases
487
488 ;merpp
489
490 * we merpp the dc currents now also from the camera reports (they have
491 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
492
493 * In the automatic analysis we omit merpping of the currents from the
494 caco files and use the lower rate camera reports from the cc files
495 instead
496
497 * merpp has been redisigned to allow merpping of the cc-reports
498 of a whole sequence. This allows to design a very simple analysis:
499 mkdir output
500 ./callisto 100776 --out=output
501 ./merpp 100776 output
502 ./star 100776 --ind=output --out=output
503 Instead of the sequence number also sequence files are accepted.
504
505 * Implemented a fix for run-numbers between 1001348 and 1001396
506 which were incorrectly assigned by the cc.
507
508
509 ;callisto
510
511 * added a filter again which was was removed in the last release.
512 it removed the most brightest events. This should not change
513 any analysis result because these events are so bright that
514 they cannot be analysed anyway, but the bad-pixel plots doesn't
515 show outliers.
516
517 * updated muon calibration constants for the periods 51-57,
518 58-63 and 67-
519
520 ;star
521
522 * The camera currents are now displayed with the rate of the camera
523 reports instead of the caco reports
524
525 ;ganymed
526
527 * if mc camera files are new enough (>=8) the source position in the
528 camera is now calculated from the stored telscope and shower
529 orientation (Note, that this might not be suitable in all cases
530 depending on the aim of the study. These case still needs
531 implementation)
532
533
534
535== Version 2.1 (2008/06/18) ==
536
537 ;Database
538
539 * introduced average temperature and wind speed from star-files
540
541 * introduced average values from Pyrometer (mainly Cloudiness)
542
543 * introduced the ratio of accepted calibration events in the
544 calibration run
545
546 * introduced the average rates of the different trigger pattern,
547 e.g. the rate of pedestal and calibration events, from the signal-file
548
549 ;general
550
551 * fixed GroupBy options in plot*.C macros
552
553 * only display KVA points (not the Tuorla points) in plotoptical.C
554
555 * all programs now allow to add resources to the ones from the resource
556 file or overwrite them from the command line. This can be done like this
557 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
558 if something seems to be wrong you can debug what the program is doing
559 using the option --debug-env=3
560
561 * increased the diversity of debug levels. That also means that with -v3
562 you get now less output, i.e. only the output which is important for
563 an analysis. To get more output which helps for debugging try 4, 5 and 6.
564
565 * fixed a problem in the task synchronizing the reading of the reports
566 and the data stream. The effect was that in some circumstances the last
567 events of some trees could have been skipped. Since this is only a
568 very tiny part of the data no severe effect to your analysis results
569 is expected (an exception might be very short, i.e. singel runs,
570 datasets).
571
572 * Dataset file now allow to include the sequence file directly within
573 the dataset file and also allow to exclude single runs from the dataset.
574 (for more details see Class reference of MDataSet)
575
576 * Sequence files now allow for excluding runs from the analysis
577 (for more details see Class reference of MSequence)
578
579 * added code to process the sum-trigger flag
580
581 * the histogram classes MH3 and MHn now support profile histograms
582
583 * the histogram classes MH3 and MHn now support labels at the axis
584
585 * the Random Forest Train-classes (MJTRain*) now store the used datasets
586 in the output file
587
588 * the MFMagicCuts have a new option to allow a linear area cut (for
589 special studies)
590
591 * The liniking of the shared object is now done into a file defined
592 by 'mktemp'. This should be a local file system which accelerates
593 liniking a lot.
594
595 * The code has been prepared for compilation with root 5.18/00d
596
597 * The MHEnergyEst histogram now shows the distribution of
598 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
599 and (Eest-Emc)/Emc vs Emc.
600
601 * fixed mars (event display) for merpped raw-data and MC data
602
603 * adapted the synatx of sequence files to allow for the new run/file
604 scheme. For more details see class description of MSequence
605
606 ;showplot
607
608 * Added support for tiff files
609
610 * Added support for csv files (tables containing tab number,
611 name and title)
612
613 * Tabs now can have a title which is displayed in the postscript file
614
615 * When multiple file are written at once (e.g. pngs from a display)
616 it is now possible to use the tab name and or tab number in the
617 file name. For details see showplos's help.
618
619 ;merpp
620
621 * Implemented cc file version 2008-02-20/0
622
623 * Implemented cc file version 2008-05-19/0
624
625 * With new options merpping can be restricted (in addition to the
626 run-number) also by telescope and file number.
627 For details see "merpp --help"
628
629 * Implemented raw data format 11 (the most important change, except
630 from plenty of changes in the format definition, is the addition
631 of the file-number in the header) If nobody makes a mistake this
632 format should have the advantage that it is by definition forward
633 compatible, so old programs will be able to read newer formats.
634
635 * Added Pyrometer information to default output (stored in a new Tree
636 Pyrometer, needs a complete new merpp, i.e. new calibration)
637
638 * Merpping (also update) can now be restricted to one single report.
639 For example:
640 If you want to update an old file with Pyrometer information call
641 merpp --only=Pyrometer --update
642
643 ;callisto
644
645 * in the pedestal processing now at least 50 processed events are
646 required for succeeding.
647
648 * the signal and calib files now contain also the sequence information
649
650 * the two MPedestalCam in the calib file now have proper names
651 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
652
653 * Both pedestal cams now contain the number of events processed
654
655 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
656 i.e. for the extraction of the calibration pulses basically the average
657 over all events of the first slice instead of all slices was used.
658 Since pedestal and calibration constants are continously recalculated
659 this only effected the very first events of every sequence.
660
661 * For the extraction of the position of the maximum sample now the
662 extraction range is set automatically to the extraction window,
663 before the whole accessible range was used.
664
665 * If the number of samples in the events and the number of samples
666 in the run-header disagrees now an error is raised (this can
667 happen in not well simulated Monte Carlo files)
668
669 * In the case of MUX-data pedestal events with the lvl1 trigger flag
670 could survive into the pedestal calculation -- fixed.
671
672 * Tab "TrigPat" added showing the distribution of the trigger pattern
673 as found in the run-files (normalized with the run length)
674
675 * The selection of events from the trigger pattern has been improved.
676 If the trigger pattern is corrupted events won't pass anymore.
677
678 * Added a new command line option --dev-null to suppress output of
679 Y-files (this is useful for test cases)
680
681 * added a new tab "CalPos" showing the arrival time of extracted
682 interleaved calibration events
683
684 * Using the new --test switch you can now calibrate the calibration
685 file
686
687 ;star
688
689 * the star file now contains also the sequence information
690
691 * Added a new command line option --dev-null to suppress output of
692 I-files (this is useful for test cases)
693
694 * Tab "Rate" added showing the distribution of the trigger pattern
695 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
696 the Y-files (normalized with the run length)
697
698 * The effective on-time calculation doesn't use events with only
699 sum-trigger anymore
700
701 * The data in the MHWeather tab has been reorganized. The never
702 working solar radiation has been removed and the data from
703 the pyrometer (cloudiness, air and sky temperature) is
704 displayed in addition.
705
706 ;ganymed/sponde
707
708 * Now data points are even shown correctly if they have error bars larger
709 than one sigma. Points with null or negative significances are omitted.
710
711 * DrawNicePlot now allows to set a projection range
712
713 * Updates pointing models. One is applied after the implementation
714 of the new LUTS in August, the other one is applied after the
715 next major change of the pointing model in October. Note that
716 these models are preliminary and give wrong results below Zd=65deg
717
718 ;sponde
719
720 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
721
722 * a new option "--force-runtime" is available. In case of very short
723 datasets (for light-curves) which are in the order of a few
724 minutes the calculated effective on-time is not very acurate because
725 it is quantizised in the order of a minute. Therefore you can switch
726 to using the real run-time instead (remakrt: this ignores any
727 dead-time!)
728
729 * a more analytical way is used to "fill" Monte Carlos into regions
730 of impact parameters which have not been simulated because the
731 trigger efficiency is assumed to be 0.
732
733 * estimated sensitivity curves for hi and lo zenith angles are shown
734 scaled to the correct observation time and collection area
735
736 * the Monte Carlo events after cuts are now written to the output file
737 if an output file given
738
739
740
741 *** Version 2.0 (2007/09/03)
742
743 - database: the position used for the pulse pos check was missing
744 in the callisto output and could thus not be filled into the DB.
745 Also the old values seemed not exactly the PulsePos used for
746 teh check.
747
748 - general: Resource file now allow an Include-Resource, i.e. you can
749 read a resource file with default settings, include it in your
750 resource file and overwrite the settings in your file. More than
751 one include file is allowed. Inclusions can be iterative.
752 Include: mydefaults.rc yourdefaults.rc
753 The resources in the first file have higher priority than the
754 second file.
755
756 - general: Now the output files (calib*.root, etc) also contain the
757 resource file (to check it open it in the TBrowser and choose Print()
758 from the context menu)
759
760 - general: Dataset files now allow to overwrite the default path
761 to search for sequence and data files. Note, that the program
762 option and individual resources will overwrite it. For example:
763 SequencePath: /magic/montecarlo/sequences
764 DataPath: /magic/montecarlo/star
765
766 - general: Fixed a problem with variables in MDataPhrase. It seems
767 that only optimdisp (didn't work) was effected.
768
769 - general: Some improvements to the optim and train processing. For
770 example the ststud window now got a proper title.
771
772 - general: The "Status Display: " was removed from the window title
773 within an Eventloop.
774
775 - general: added a new flexible histogram-class (MHn) which can be used
776 for example in testing after optimizations or training to produce
777 user defined histograms.
778
779 - general: The Random Forest now allows attaching an evaluation
780 function which is applied to its output. This allows to train
781 on whatever you like (eg. train on log10(energy), but return
782 energy)
783
784 - general: The Random Forest training of energy (trainenergy.c) and
785 disp (traindisp.C) has been improved by more graphical output to
786 judge the result.
787
788 - general: The training of energy (trainenergy.C) has been improved
789 a lot by training on a different quantity than energy. It gives
790 a result which is highly independant of the source spectrum
791 and shows lower bias than all other options.
792
793 - general: Dataset files are allowed to contain collections of
794 datasets. For more details see the class reference of MDataSet.
795
796 - general: The default WobbleMode in a datset file now (if not
797 overwritten) is "auto", i.e. wobble mode is set if the dataset
798 doesn't contain off-sequences.
799
800 - merpp: Merpp can read file format version 9 now. Please realize
801 that for file format version 9 the extraction range is different
802 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
803 the first and last 15 slices have been removed from all MUX data.
804
805 - mars: Similar to writing movies you can now select events which
806 should be displayed in your display. Therefore add the following
807 lines to your mars.rc:
808 MFEvtNumber.FileName: ganymed00223552.root
809 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
810 The input file can be a ganymed-file after (ganymed*.root) or
811 before (ganymed*-summary.root) file. For example to select all events
812 from your on sample after cuts (excluding the ThetaSq cut) use
813 MFEvtNumber.Selector: DataType.fVal>0.5
814 To show all events from your on-sample after quality cuts
815 use the summary file instead.
816
817 - mars: new ways to call mars are implemented. Instead
818 of calling
819 mars filename.root
820 you can now also use
821 mars sequence.txt
822 or
823 mars sequence.txt inputpath
824 or replace sequence.txt by the sequence number if the default
825 sequence file should be used.
826
827 - mars: The default size has been increased
828
829 - mars: There are two new heckboxes which allow to switch off
830 the calculated image parameters
831
832 - callisto: was broken for MCs... fixed.
833
834 - callisto: improved calculation of spline coefficients a lot. This
835 leads to a further improvement of the event rate calibrating MUX
836 data of about 15% (175evt/s instead of 150evt/s)
837
838 - callisto: finally the raw data we read is now real 16bit (with
839 10bit precision) for MUX data and not a stripped 8bit number
840 anymore. Due to scaling of the numbers (without precision loss
841 into an [0-256[ range, the final numbers for pedestal, pedestalrms
842 and extacted signal don't change. However, at all places where
843 raw data is directly accessed (eg. saturation and variation
844 limits in the signal- and pedestal-extraction) the numbers
845 refer still to the data's 16bit range.
846
847 - callisto: The maximum arrival time difference used in the bad
848 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
849 for both, old FADC and MUX-FADC, data.
850
851 - callisto: Be aware that callisto is now calibrating the arrival time
852 in nanoseconds rather than time slices. Also all following tasks
853 have been changed to assume ns units now. If you star data
854 calibrated with an older version it might be necessary to adapt
855 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
856 to obtain optimal results. The plot in the PulsePos tab
857 will now be in ns, too. This might also mean that the Muon
858 analysis in star might not work as perfect as expected as long
859 as old files read in.
860
861 - callisto: The calibration constants of earlier updates got lost
862 somehow. All constants have been updated.
863
864 - star: The PSF is now determined from the profile of the ArcWidth
865 instead of arcwidth/radius. The old way gave to much weight
866 to the bins with low statistics. The reference lines have been
867 updated.
868
869 - star: For speed reasons events suitable for the muon analysis
870 are now also preselected by fConcCOG<0.1 which seems to be a very
871 good preselector for muons.
872
873 - star: is now calculating a new timing parameter the Slope along
874 the major and minor axis of the shower. Therefore a numerical
875 solution of a line-fit is used. To use MHillasExt.fSlopeLong
876 and MHillasExt.fSlopeTrans don't forget to multiply it with
877 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
878
879 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
880 have been removed from MNewImagePar. They have never been good for
881 anything.
882
883 - star: Implemented a new recursive algorithm which is supposed to be
884 faster. Also implemented new cleaning oiptions, which are:
885 + CleanLevel0:
886 The cleaning level above single core pixels can be kept
887 + KeepIsolatedPixels:
888 Define whether single core pixels should be kept
889 + TimeLevel1:
890 The coincidence window in nanoseconds to single used neighbors
891 + TimeLevel2:
892 The coincidence window in nanoseconds to two used neighbors
893 + PostCleanType:
894 MOde in which a time dependent post cleaning should be applied
895 0: No post cleaning
896 1: Require for each used pixels at least one used neighbor
897 within a time-window of CleanLevel1
898 2: Require for each used pixels at least two used neighbor
899 within a time-window of CleanLevel2
900 3: Require first two and second one used neighbor
901 within a time-window of CleanLevel1 and fCleanLevel2
902 respectively
903 + RecoverIsolatedPixels:
904 - recoveres isolated core pixels if they have a used neighbor
905
906 - mars/star: The new default cleaning is:
907 + CleanLevel1: 6.0
908 + CleanLevel2: 3.0
909 + CleanTime1: 1.75
910 + CleanTime2: 1.75
911 + PostCleanType: 3
912
913 - star/ganymed: The old spark-cuts have been replaced by new ones.
914 These new spark cuts have been cross checked with the sequences
915 84720 (before splitter), 101041 (after splitter) and 223539 (new
916 FADCs). In all cases they seperate pretty well, but of course not
917 perfect. Monte Carlos have suggested to tighten the cuts a little
918 bit further at low sizes. This has been done.
919
920 - ganymed: IMPORTANT - The spark cuts have been changed to match
921 all available data more or less well. This might mean that for
922 YOUR data there are still sparks visible.
923 Whenever you do an analysis you have to make sure that NO sparks
924 survive your cuts!
925
926 - ganymed: The old hadronness and size cuts have gotten new indices
927 (10, 11). The old indices 8 and 9 now mean an additional condition
928 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
929 If you want to switch off this cut just move the line far away enough,
930 e.g. by setting c[9] to -500. Please update your ganymed.rc files
931 accordingly!
932 The unit of c[9] is deg. It is the dist at which your cut will
933 cross the slope==0. The unit of the slope is ns/deg. So if
934 you readin files calibrated with an older Mars-version you
935 have to adapt the default value for c[9] to the FADCs:
936 - Multiply by two for the MUX FADCs (run number > 200.000)
937 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
938 - Multiply by 42 for the meaning of life (run number = 200.000)
939
940 - ganymed: The old Cut0 is now called CutQ and is calculated before
941 the source position is caluclated. If you need a quality cut
942 including source dependant data (be very carefull with this!)
943 you have to use Cut0 instead.
944
945 - ganymed: now properly supports three off regions in wobble mode.
946 It will be the default from now on in ganymed_wobble.rc. To change
947 the number of off-regions use
948 NumOffSourcePositions: 1
949 in your ganymed.rc. Also by default no off-theta cut will be done
950 anymore so that you will get a background level higher than the
951 signal level in your ThetaSq plot for ThetaSq>0.2.
952 Due to this be carefull changing the scaling mode away from
953 "None". You will underestimate your signal if your scale interval
954 is not properly set.
955 (Rem: ThetaSqN is no longer needed)
956
957 - ganymed: is now storing the events of all (on- and off-)
958 source positions even in the case of more than one off-source
959 position. This should allow sponde to work properly and the
960 energy estimation is done correctly in all cases (without any
961 "nearest position" trick)
962
963 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
964 with a real pointing model for the starguider is done, calibrated
965 with more than thousand tpoints taken from this date on.
966
967 - ganymed: was broken for Wobble-MCs... fixed.
968
969 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
970 has changed. Note that your old ganymed.rc will be incompatible
971 with the new algorithms! Please check the ganymed.rc files and
972 the class description of MFMagicCuts for more information.
973 It is recommended at the moment to use identical Disp-Parametrizations
974 for on/off- and wobble-mode. If cuts are optimized only
975 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
976 should be optimized. All other values should be kept as they are.
977 If you want to do an anylsis without timing a parameters, you can
978 switch off the timing cuts by seeting parameter 7 to a very small
979 value (eg. -99). To remove the slope parameter from the disp
980 paremtrization set parameter 8 to 0.
981
982 - ganymed: The distribution of observation time versus zenith
983 angle is now shown for off- AND on-data.
984
985 - ganymed: The contents of the source position plot are no longer
986 averaged, thus a lot of (fake) events between the two wobble
987 positions have disappeared.
988
989 - ganymed: There is a new tab "CutT" it contains the VsSize plots
990 with the CutT, whihc is defined in ganymed.rc, applied. It
991 is resonable to use your theta-cut for it, to see if there is
992 something strange (sparks!) in your signal-region.
993
994 - ganymed: To choose a dataset from a collection in a dataset file
995 use the new command line option "--dataset=12345"
996
997 - optim, sponde: should now properly support three off-regions.
998 Just produce your ganymed summary files with three off-regions.
999 optim and sponde will automatically get all off events from
1000 all off-regions from this file. Please do not forget to
1001 set the scaling in optimwobble.C properly:
1002 fit.SetScaleUser(1./3);
1003 it is not yet read in automatically (will follow soon).
1004 In the case of fixed Scale you can also use
1005 cuts.SetThetaCut(MFMagicCuts::kOn);
1006 no off-cut needed.
1007 Be carefull in case of three off-regions when switching on
1008 scale mode. Make sure that the scale interval is set correctly.
1009
1010 - sponde: sponde.rc and sponde_onoff.rc are now idetical
1011
1012 - sponde: the resouce files have been rewritten with a lot of
1013 comments and a well working parametrization for an energy estimator
1014
1015 - sponde: In the estimated energy versus monte carlo energy plot the
1016 contents where exchanged.... fixed.
1017
1018 - sponde: the so called "accurate"-mode has been removed. It didn't
1019 give any improvement in accuracy, only decreased execution speed.
1020
1021 - sponde: the so called "simple"-mode has been removed. It didn't
1022 give any improvement in simple.
1023
1024 - sponde: the so called "refill"-mode has been removed. It was anyhow
1025 not implemented.
1026
1027 - sponde: now checks whether the theta distribution of your on-data
1028 and the theta-distribution of your Monte Carlo sample (after
1029 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
1030 sample is incomplete) execution is stopped. Execution can be forced
1031 using the new option --force-theta. Use this option with care!
1032
1033 - sponde: Proper collection areas can now be constructed also from
1034 Monte Carlo samples generated with different maximum impact
1035 parameters. Note that in previous version you neither got
1036 a warning or failure, nor was there any obvious sign that the
1037 collection area was overestimated due to usage of files with
1038 different maximum impact parameters.
1039
1040 - sponde: If MC files with different lower energy limits are used
1041 the primary MC spectrum is artificially completed down to the
1042 lowest energy used at all. WARNING: that this gives correct
1043 collection areas ONLY if none of the events in this region would
1044 survive your cuts at all.
1045
1046 - sponde: the output file now contains more information about
1047 the spectrum (eg. the full 2D collection area histogram).
1048 Note, that this information can only be written to the file
1049 if it is stored automatically via command line argument.
1050 If you only store the status display from within the display
1051 the information is lost.
1052
1053 - sponde: added a new tab "Disp". It shows the residual of the disp
1054 (Disp-Dist) versus several parameters and it is meant to judge the
1055 quality of the disp estimator. In the ideal case the residual is zero
1056 and doesn't depend on any variable. The tab is displayed after
1057 CutQ and Cut0.
1058
1059 - sponde: added a new tab "Energy". It shows the residual of the
1060 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1061 several parameters and it is meant to judge the quality of the
1062 energy estimator. In the ideal case the residual is zero
1063 and doesn't depend on any variable. In reality even a good estimator
1064 can show residuals versus Monte Carlo energy. The tab is displayed
1065 after all cuts.
1066
1067 - sponde: added a new tab "EventDist" showing the unweighted real
1068 absolute number of events of your sample after cuts. This tells
1069 you how many events with this energy you had in your MC files.
1070 The same information you get from the error bars of the weighted
1071 histograms, but this is less intuitive.
1072
1073 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1074 for comparison. It is not meant to show these curves in
1075 publications, they are only for production.
1076
1077 - sponde: The OriginalMC tree with the events produced by corsika
1078 is now processed only once
1079
1080 - sponde: Finally fixed most annoying bug, which has effected the
1081 last bin of the collection area. It was the problem that binnings
1082 of root histograms are from 1 to n (included) but there was a C-like
1083 loop in sponde from 0 to n (excluded). Now the loop also includes
1084 correctly under- and overflow-bins. The worse thing with this is,
1085 that for the events in the highest bin not only the bin-content
1086 was wrong, but also the weights applied to these events, which could
1087 in pricipal effect also other parts of the distribution (eg. due
1088 to energy estimation). Fortunately it effected only a few events
1089 in most cases.
1090
1091
1092
1093 *** Version 1.2 (2007/05/14)
1094
1095 - database: The database now has two new values Unsuitable50 and
1096 Unsuitable01. They express the number of pixels which are
1097 unsuitable for more than 50%, respectively more than 1%, of
1098 all calibrated event. It is a more accurate number than the
1099 previously used numbers, because they only take the first
1100 calibration (ignoring the interleaved calibrations) into account.
1101
1102 - database: The database now has two other new values UnsuitableMax and
1103 DeadMax. They express the maximum number of pixels which were
1104 unsuitable, respectively dead, during the sequence. Because
1105 of high pedestal rms (cars passing) a few events with very high
1106 numbers of unsuitable pixels can happen. Not to suffer from this
1107 effect we don't take the highest 0.1% of the numbers into account.
1108
1109 - general: fixed a bug which caused callisto and star to stop working
1110 properly because the callisto output was currupted
1111
1112 - general: a script called scripts/makemovie has been added which
1113 simplified the process of producing several movies from a single
1114 sequence with different setup.
1115
1116 - callisto: Some more code cleanup. Started to remove old obsolete
1117 code from cvs.
1118
1119 - callisto: The extraction of the pedestal with the extractor was
1120 not random. It seems that extracting at one position is still biased
1121 (for example in the first or last slices we could still suffer from
1122 switching noise) Now it is completely random.
1123
1124 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1125 pedestal files) individual pixels could be skipped due to high
1126 variations. This was already the case for the pedestal extraction
1127 from the lo-gains since the beginning and properly handled
1128 there, but was introduced in the extraction from the pedestal files
1129 a while ago. To calculate the average value it was still divided
1130 by the number of events procesed not by the number of summands
1131 really summed. This let to a pedestal which was a tiny amount too
1132 small (for a few piels in the order of 0.1%). This led to an slightly
1133 positive offset of the randomly extracted pedestal for a few pixels.
1134 I doubt that this has a big effect on the result, because the effect
1135 on the individual numbers is quite small. Due to this it is suggested
1136 that you rerun your calibration to make sure you are without any
1137 avoidable bias.
1138
1139 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1140 the median rms of the absolute arrival time and expressed in significance
1141 levels. This replaces the old meaning of an abolute upper limit. An
1142 absolute upper limit doesn't make much sense, because in our data
1143 all arrival times are shifted at the same time (in fact it might be
1144 a shift of the artificial trigger w.r.t. to the light flash).
1145
1146 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1147 of the number of unsuitable pixels over the whole sequence. This
1148 is usefull mainly to judge if an intermediate calibration had
1149 problems.
1150
1151 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1152 of the number of dead pixels over the whole sequence. Dead pixels
1153 in this context are unmapped pixels, i.e. pixels which could not
1154 be interpolated, and thus are ignored in the further analysis.
1155
1156 - callisto: It is now possible to use the position of the maximum
1157 of the spline as arrival time instead of the leading edge even
1158 when using the integral for the signal. Therefor set the extraction
1159 type to kIntegralRel ("IntegralRelative") and the relative height
1160 ("HeightTm") to -1:
1161 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1162 MJPedestalC1.ExtractSignal.HeightTm: -1
1163
1164
1165
1166
1167 *** Version 1.1 (2007/04/27)
1168
1169 - general: The new class MGeomCamDwarf contains the camera geometry
1170 for our prefered Dwarf camera and can be used to create general
1171 geometries of roundish or hexagonal cameras.
1172
1173 - mars: The default cleaning is now abolute 8.5/4.0.
1174
1175 - mars: The resource file mars.rc now contains examples for MUX data
1176
1177 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1178 data containing only 10-bit information is still cooked down to
1179 8-bit, by cutting away the lowest 8-bit.
1180
1181 - merpp: When reading raw data the data is now stored in a single
1182 array. The lo-gain array is obsolete. The interface stays the same.
1183
1184 - callisto: To process the new MUX data use the resource file
1185 callisto_mux.rc
1186
1187 - callisto: The -root and -raw options to read merpped raw data have
1188 been removed
1189
1190 - callisto: If the -mc option is given the sequence-name can now be
1191 replaced by the MC sequence number
1192
1193 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1194 -mc option can now be omitted
1195
1196 - callisto: Started further simplification by removing obsolete
1197 dependancies on MCalibIntensity*Cams.
1198
1199 - callisto: removed unsused intensity calibration from MJCalibration
1200 for further simplification
1201
1202 - callisto: for simplification removed references to
1203 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1204 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1205 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1206 (this should at minimum change nothing at all, and at maximum
1207 improve thing if these containers where somewhere not handled
1208 properly)
1209
1210 - callisto: Added the option to write an event movie. Please use
1211 this option with care (huge files) but exessively to understand
1212 our events. For further documentation please refer to the
1213 IACT wiki
1214 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1215
1216 - callisto: Improved binning for the pulse position check histogram
1217
1218 - callisto: The code calculating the pulse position checknow takes
1219 the pedestal into account
1220
1221 - callisto: The arrival time is now stored with full precision this
1222 helps to get rid of artefacts in histograms. For the signal this
1223 is not necessray because it is displayed in log-scale anyhow
1224
1225 - callisto: Fixed a problem with internal exclusions. Pixels which
1226 have once been marked as unsuitable didn't get the necessary
1227 histograms filled anymore to be rechecked with each interleaved
1228 calibration.
1229
1230 - callisto: The relative arrival time resolution (the rms of the
1231 relative arrival time offset) is now checked against its
1232 median and the median deviation, instead of the average
1233 plus an absolute offset.
1234
1235 - callisto: The relative arrival time offset is now calculated
1236 w.r.t. its median not w.r.t. to an artificial reference pixel.
1237
1238 - callisto: The relative time calibration now marks pixels with
1239 outlaying offset as unsuitable
1240
1241 - callisto: The interleaved relative time calibration has been switched
1242 on. The advantage is that pixels which are marked as outliers
1243 now can recover. An improvement over time is not expected, because
1244 the relative time calibration seems stable.
1245
1246 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1247 option can now be omitted.
1248
1249 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1250 or the option "-mc" is specified as default the monte carlo datacenter
1251 paths (/magic/montecarlo/...) are used if not overwritten in the
1252 dataset file.
1253
1254 - ganymed: The output files now contain run- and event-number for all
1255 events, accessible as RunNumber.fVal and EvtNumber.fVal
1256
1257 - ganymed: Added a plot showing the source position in the camera also
1258 for wobble mode
1259
1260 - ganymed: In addition to the existing task which can be setup to
1261 be executed after Cut1 a final task called "EstimateEnergy"
1262 has been added, executed before writing the final output
1263 (ganymed00000000.root). The task setup in all three cases
1264 can be choosen individually. (For all three(!) cases you
1265 can for example choose MRanForestCalc. For examples see all
1266 sponde*.rc and all ganymed*rc)
1267
1268 - ganymed: If a container "MEstimatedEnergy" is found in the
1269 parameter list (eg. because it was setup by MEstimateEnergy)
1270 it will be written to the output file.
1271
1272
1273
1274 *** Version 1.0 (2007/02/16)
1275
1276 - database: Website to plot values from the database has been added.
1277
1278 - database: The rate of spark events as found by star is now kept
1279 and the rate after cleaning is now with spark events subtracted
1280
1281 - general: The changes to the interpretation of phrases lead to
1282 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1283
1284 - general: Added example files how you can create your own calendar
1285 (eg. as christmas present) with Mars. Just run
1286 root macros/tutorials/calendar.C
1287
1288 - general: Added a possibility to display grouped data in the plotdb.C
1289 macro (and similar macros). This allows to plot hourly, nightly,
1290 weekly, monthly and yearly averages.
1291 For more details see the plotall function of the macro
1292
1293 - general: fixed the error display of the camera display. It showed
1294 wrong results.
1295
1296 - general: fixed a memory leak when reading many MStatusDisplays
1297
1298 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1299 between a spherical and a parabolic mirror
1300
1301 - callisto: We have a new pulse position check which takes the properties
1302 of the extractor automatically into account. So no need to set
1303 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1304 left is done. If possible the lo-gain extraction start and hi-gain
1305 extraction end is changed accordingly. If no proper extraction range
1306 can be set (hi-gain too much to the left) an error is raised.
1307
1308 - callisto: New swapped pixels have been found and corrected
1309
1310 - callisto: Redone the signal extraction this includes:
1311 + Unified the algorithms to extract the pedestal for all pedestal
1312 extractions done
1313 + Unification of hi- and lo-gain into one array
1314 + Unification of hi- and lo-gain extraction for Spline and
1315 Digital Filter (means now exactly the same algorithm is used,
1316 not a copy-and-pasted one)
1317 + Store pedestal subtracted data in a common place
1318 + Improved extraction algorithms. If the algorithms search a
1319 maximum but don't find one they don't return the maximum anymore
1320 + Improved the extraction such that a information for signal
1321 and time which is consistent is returned
1322 + replaced the numerical spline with a (not slower) analytical
1323 solution
1324 + Lowered the saturation limit from 250 to 245 to make sure that
1325 we are far away in all pixels from problems with the clock-noise
1326 + The start of the lo-gain extraction is calculated from the hi-gain
1327 arrival time. In case of saturation an estimation is used.
1328 + the hi-gain window was extended to slice 16. This allows extraction
1329 of very late pulses in single pixels or of huge hadron showers.
1330 + Now uses the lo-gain extraction range for pedestal extraction,
1331 not the hi-gain range in the lo-gain
1332
1333 - callisto: New hi-/lo-gain calibration constants have been produced
1334 for all periods from the statistic of the whole period. They are
1335 now used automatically depending on the periods. The old constants
1336 where deviation in avarega about 2%-3%. The constants are very
1337 stable from period to period (<<1%) except for exchanged channels.
1338 In a few cases the constants used so far were off by 1%-2% (maybe
1339 temperature effects?)
1340
1341 - callisto: To gain obsolete space we do not write the
1342 MPedestalFundamental anymore. Also calibration and bad pixel
1343 treatment is not done for it anymore because it has never been used.
1344
1345 - callisto: Fixed a bug in the seuqence handling which caused the
1346 light condition to be ignored
1347
1348 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1349 basically the same as "Cleaned" but the distribution devided into
1350 the events fullfilling a spark cut or being rejected by it.
1351 This cut can be changed from star.rc (see example inside) by
1352 the "SparkCut" directive
1353
1354 - star: Star displays now the average individual pixel-rate (IPR) versus
1355 time and the average discriminator threshold (DT) of all pixels.
1356
1357 - optim: fixed a problem with the optim-macros which was due to a bug
1358 in the new phrase parsing
1359
1360 - ganymed: To get a nice FalseSource plot (instead of the all-information
1361 debug plot displayed as a standard plot) use the context menu
1362 somewhere between the two upper plots, click on "DrawNicePlot"
1363 and enjoy the result. (It is the same context menu which contains
1364 the other options)
1365 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1366
1367 - ganymed/optim/train: The cut program, trainings- and optimization
1368 macros could run with less files found than expected from the
1369 sequence-files. No the execution is stopped in this case.
1370
1371 - ganymed: now stores the dataset in the output file with all information
1372 contained (as sequence number, sequence path, data path) so that the
1373 used dataset file can be recreated complete from the output
1374
1375 - sponde: now also allows the uasge of random forest
1376
1377 - sponde: added a plot showing the cut efficiency
1378
1379 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1380 errors (eg. effecting the collection area) because the errors of the
1381 two histograms were swapped in the calculation, which makes a difference
1382 in the case the histograms contains weighted events. Aditionally the
1383 totalarea was incorrectly taken into account, which results in too small
1384 errors, which makes a difference at low statistics were the errors
1385 or the collection area dominate.
1386
1387
1388
1389 *** Version 0.10.3 (2006/10/23)
1390
1391 - database: Implemented ObservationMode flag in websites.
1392
1393 - database: For sequences there is now also the stoptime available on the
1394 websites.
1395
1396 - database: Removed ManuallyChanged flag from sequence-info websites,
1397 as it is not needed anymore with the new sequence building algorithm.
1398
1399 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1400 Class for calculation of confidence intervals (upper limits).
1401 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1402 Please read the class instruction of TRolke for more information.
1403
1404 - general: The programs now return 0xfe if the requested resource file
1405 doesn't exist.
1406
1407 - general: Errors comming from root itself are now not output to
1408 stderr anymore but to our default (colored) log-stream.
1409
1410 - general: Changed the interface to TFormula such that now everything
1411 is parsed by TFormula, which should allow to use phrases even
1412 without paranthesis correctly parsed.
1413
1414 - callisto: replaced the AdHoc number of effective integration slices
1415 in the digital filter by an average of the correct number, averaged
1416 over all possible set of weights. This also gives correct numbers
1417 for the lo-gains which were totally wrong before.
1418
1419 - callisto: drastically reduced memory consumption by not storing
1420 all intermediate calibration results in memory anymore (we might
1421 write them into a file in the future)
1422
1423 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1424 debug plot displayed as a standard plot) use the context menu
1425 somewhere between the two upper plots, click on "DrawNicePlot"
1426 and enjoy the result. (It is the same context menu which contains
1427 the "DrawAll" option)
1428 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1429
1430
1431
1432 *** Version 0.10.2 (2006/10/15)
1433
1434 - general: changed the building of the sequence files such, that
1435 the source-/project name in case of wobble-sources is not the
1436 source/project of the first data run anymore but the new generalized
1437 wobble source/project
1438
1439 - general: Added some functions to MAstro to calculate sun and
1440 moon properties
1441
1442 - general: Added two new macros (starvisday.C and starvisyear.C)
1443 which allow to plot the visibility of several stars in one day
1444 or of one star along one year
1445
1446
1447
1448 *** Version 0.10.1 (2006/10/11)
1449
1450 - general: HTML logging output was distorted... fixed.
1451
1452 - general: Changed the writing of the sequencefiles such that only
1453 as many pedestal files as giving at least 1000 pedestal events which
1454 are nearby the first calibration run are used as pedestal runs
1455
1456 - sponde: In the calculation of the collection area(s) and the
1457 distribution for MOnte Carlo and estimated energy the error
1458 calculation was wrong because root didn't take the errors
1459 properly into account... fixed.
1460
1461
1462
1463 *** Version 0.10 (2006/10/10)
1464
1465 - general: all executables now check consistency of the root version
1466 installed with the root version used for compilation. The return
1467 code in this case is 255.
1468
1469 - general: The algorithm to build seqeunces has been redesigned
1470 completly. It is now more flexible in terms of a resource file
1471 resources/sequences.rc which can be used to partly overwrite
1472 the default algorithm and defined the important part of the
1473 algorithm. It also takes correctly into account several ways
1474 of taking wobble-data. Currently the new algorithm doesn't take
1475 the number of pedestal events anymore into account (so a sequence
1476 could have much less than 1000 pedestal events and data runs are
1477 no-more used instead)
1478
1479 - general: a lot of small changes to make the code compatible with
1480 root 5.12/00 and gcc 4.1
1481
1482 - general: Fixed some warnings thrown if more warnings are switched
1483 on in the compiler
1484
1485 - general: Added a function to MMath which returns the Median of
1486 the distribution abs(y[i]-median) but at 68:32 division instead
1487 of 50:50, which is somehow the median counterpart of the rms.
1488
1489 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1490 even if they are compressed with gzip (recommended compression
1491 is with "-1")
1492
1493 - showplot:
1494 + batch mode creation of image files now works with root 5.12/00
1495 + added support for writing bmp (though it never produces
1496 bmp which can be read by programs like xv or gimp)
1497 + added support for xml
1498 + added new option to start the display with a different size, by
1499 --display-width=nnn or --display-height=nnn
1500 + added options to define the canvas size when the display is started
1501 --canvas-width=nnn or --canvas-height=nnn
1502 the option can also be used for batch-mode conversion
1503 + added an option which automatically fits the display size to the
1504 desktop-size: --auto-size
1505
1506 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1507
1508 - merpp: allow the reports to have 1000ms due to a bug in the camera
1509 program.
1510
1511 - callisto: New swapped pixels have been found and corrected. For
1512 details see MRawRunHeader::FixAssignment()
1513
1514 - callisto: Callisto now raises an error if one of the input files could
1515 not be opened.
1516
1517 - callisto: In some rare cases it could happen that in the signal
1518 extraction of the digital filter the extractor returned nonsense
1519 results due a wrong initializion of a variable (this happens in
1520 cases in which the extracted signal is exactly zero or the
1521 digital filter couldn't slide because of a too small extraction
1522 window, which could happen in the lo-gain extraction)
1523
1524 - callisto: The lo-gains have been marked as valid in some cases
1525 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1526 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1527 smaller than the number of slices (fLoGainWindowSize) needed
1528 by the lo-gain extractor
1529
1530 - callisto: Updated absolute calibration constants (muon calibration)
1531
1532 - callisto: fixed a bug which caused the hi-gain saturation not
1533 to be handled properly in the spline (the position of the
1534 saturation was calculated incorrectly)
1535
1536 - callisto: fixed a bug which gave weird results if hi- _and_
1537 lo-gain could not be extracted properly. In some cases hi-
1538 and lo-gain have not been extracted at all and the random result
1539 got calibrated. In other cases the hi-gain was saturating and the
1540 lo-gain has not been extracted. For this a completly arbitraty
1541 scale factor was applied to the result from extracting the
1542 charge of the saturating hi-gain.
1543
1544 - callisto: improves handling of extracted signal if lo- and/or
1545 hi-gain could not be extracted properly. If no appropriate
1546 calibration of either the signal or the arrival time is possible
1547 the pixel is now markes as unsuitable instead of estimated.
1548
1549 - callisto: Fixed a problem in the spline extraction which gave
1550 weird results if the signal was extracted from the first (and
1551 highest) slice (as a workaround extraction from the first
1552 slice has been forbidden)
1553
1554 - callisto: Fixed a bug regarding the use of the QE which doesn't
1555 effect the result because the default is used anyhow.
1556 (The bug was there since 14/07/2005)
1557
1558 - callisto: Changed the default for fgLoGainStartShift to -2.4
1559
1560 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1561 factors to be always 10 for all pixels as soon as the first
1562 calibration update has happend.
1563
1564 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1565 was off by more than one slice (which gives wrong values for
1566 pixels which have saturated the hi-gain) This was a problem
1567 mainly for timing studies, not so much for the automatic standard
1568 analysis. Also the values for the Spline have been changed slightly:
1569 + Digital Filter from 1.70 to 0.95
1570 + Spline from 1.39 to 1.30
1571 The numbers were sorted out by an extensive test in the
1572 test-database.
1573
1574 - callisto: Removed the tab showing the average calibrated arrival
1575 time. It never gave useful information.
1576
1577 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1578 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1579 and both were extracted because the hi-gain was above the
1580 LoGainSwitch.
1581
1582 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1583 lo-gain pulse position (after application of LoGainOffset, which
1584 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1585 have saturated and both were extracted because the hi-gain was above
1586 the LoGainSwitch.
1587
1588 - callisto: After extensive tests a new threshold level for determination
1589 of the pulse position has been found at 50phe. This is due to the
1590 fact that for lower pulses the arrival time changes its average
1591 behaviour dramatically. It tends to the average of the extraction
1592 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1593
1594 - callisto: Added two more plots to the calibration part. The average
1595 extracted signal and the average extracted arrival time as
1596 extracted by the signal extractor (This can help debugging problems
1597 because it doesn't involve a fit)
1598
1599 - star: changed the fit for the effective on time such that initial
1600 values are calculated automatically now instead of using build
1601 in values. This makes the fit more indepedant of the underlaying
1602 rates. With a test of ~350 sequences in the test database it could
1603 be shown that the new fit gives the same result +/-1sek.
1604 The highest deviation was +5s the lowest -10s. You can now control
1605 the bahaviour with two resource values:
1606 MHEffectiveOnTime.FistBin: 3
1607 MHEffectiveOnTime.NumEvents: 12000
1608 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1609 from the resulting gamma candidates
1610
1611 - star: The Center histogram in MHHillas is now by default displayed
1612 with the colz draw-option
1613
1614 - ganymed: now produces valid error codes if failed
1615
1616 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1617 with the option "hadronness" instead of "area" or "both" if
1618 you want to use both cuts. The hadronness cut includes a fixed
1619 cut in hadronness (index 8) and a fixed cut in size (index 9).
1620
1621 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1622 the M3Long of the anti source to be not properly evaluated
1623 (actually is was evaluated as a unique random number) in case
1624 of optimization with anti-theta cut switched on. This might have
1625 lead to improper, but not necessarily wrong, optimization results.
1626
1627 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1628 how to use random forest
1629
1630 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1631 ganymed_onoff.rc. Seems to be unintentional that they were different.
1632
1633 - sponde: Since the introduction of the possibility to define a
1634 normalization energy instead of using the integral the default
1635 was not using the integral anymore but a normalization energy of
1636 1GeV. It is now the integral again.
1637
1638 - sponde: Fixed a problem in the weighting which did not allow
1639 a MC slope of -1.
1640
1641
1642
1643 *** Version 0.9.6 (2006/05/24)
1644
1645 - general: changed the binning of the azimuthal profile of the camera
1646 such that it is aligned with the 60deg boundaries.
1647
1648 - merpp: better handling of problems with the TH, TD part of the
1649 CC-REPORT for files older than 200507190 and 200412210
1650 respectively
1651
1652 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1653
1654 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1655
1656 - callisto: if an arrival time is extracted outside the fadc range is
1657 was set to the boundary before. Now a random number is assigned
1658 instead to avoid unfortunate coincidences of arrival times just
1659 by this arbitrary value.
1660
1661 - callisto: added a new option to callisto.rc which allows
1662 to set the maximum arrival time difference allowed for the
1663 badpixel algorithm to determin whether a pixels belongs to a shower:
1664 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1665
1666 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1667 to 0.9 as suggested by Stefan due to a recent study on the fraction
1668 of pixels surviving the image cleaning
1669
1670 - callisto: switched off error in case of "pulse is too much to the left"
1671
1672 - callisto: The extraction window is not adapted anymore. This means that
1673 the pulse is extracted from the full range. The draw-back is that the
1674 background (pedestal) will become slightly higher. Switching on/off
1675 the PulsePosCheck in the callisto.rc only effects filling the
1676 histograms.
1677 WARNING: If the pulse is too much to the left data is calibrated!
1678 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1679 in the database to make sure that your data is valid!
1680
1681 - star: Show also the number of stars correlated correctly by the
1682 starguider
1683
1684 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1685 than one off-source region in wobble-mode. To use it add the following to
1686 your ganymed_wobble.rc:
1687 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1688 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1689 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1690 + Cut1.ThetaCut: None
1691 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1692
1693 - ganymed: in the case the latest report is older than a default (currently
1694 one minute) and the current report will be skip the starguider
1695 correction and calibration will be reset. The maximum age can be
1696 setup from ganymed.rc by (minutes):
1697 MPointingDevCalc.MaxAge: 1.5
1698
1699 - ganymed: A first implementation showing all size-bins for the theta-sq
1700 resp. alpha-plots in a single tab automatically
1701
1702
1703
1704 *** Version 0.9.5.1 (2006/05/05)
1705
1706 - general: Added a new option "zdiff" to the Makefile which runs
1707 "cvs diff" as "make diff" would do, but with compression
1708
1709 - general: accelerated MTFillMatrix (used for eample in all training
1710 and optimization macros) by skipping some obsolete calles in the
1711 eventloop the first and second loop could be accelerated by ~20%
1712
1713 - general: Added a missing feature in the MFilterList class which
1714 prevented MFEnergySlope from working correctly in trainenergy.C
1715
1716 - general: Accelerated the random forest training and usage a bit
1717
1718 - merpp: Adapted to new raw data file format version 6
1719
1720 - merpp: fixed a problem with reading the starguider reports
1721 after 6.3.2006
1722
1723 - callisto: At some times six pixels had to be exchanged manually in the
1724 data. If the pixels to be swaped are both not found, an error was raised
1725 and calibration was stopped. Now it is assumed they are intentially not
1726 mapped and the Error has been changed to a Warning.
1727
1728 - star: Added new image cleaning based on the arrival time of the shower.
1729 The new cleaning can be accessed using the parameter "Time" instead of
1730 the the old one (like "Absolute) in the star.rc-file.
1731 Recommended parameters:
1732 + MImgCleanStd.CleanLevel1: 8.2
1733 + MImgCleanStd.CleanLevel2: 5
1734 + MImgCleanStd.CleanRings: 2
1735 + MImgCleanStd.KeepSinglePixels: No
1736
1737 - star: Simplified the calculation of the effective on time. By letting
1738 the fit start in the third bin the result should become more stable.
1739 The fit quality is now ignored for the theta-plot which is not used
1740 in the analysis later. Still better pre-cut which, for example,
1741 remove events triggered by car-light (rate changing on a short
1742 time-scale) are missing.
1743
1744 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1745 for optimization (kWeakSource) which is suggested by the Berlin
1746 people for weak sources.
1747
1748 - macros: plotdb.C:
1749 + if no dataset and no time-interval is given only sequences with
1750 an effective on-time above five minutes are plotted anymore
1751 + added a new tab "RelTime" displaying the relative on-time
1752 (effective on-time divided by the observation time)
1753
1754 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1755 the optimization became a lot faster
1756
1757 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1758 To display them just delete the pads displayed on top.
1759
1760 - ganymed: fixed a bug which could cause strange behaviour in wobble
1761 mode if no starguider information was available due to an incorrect
1762 initialization of the starguider calibration
1763
1764 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1765 be changed from within the plot. It can also be setup from the
1766 resource file using:
1767 + MHDisp.fScaleMin: 0.325
1768 + MHDisp.fScaleMax: 0.475
1769
1770 - ganymed, showplot: Fixed a problem with the fit to the off-data
1771 (HistOff) which could cause a time lag or an inifinite loop.
1772 The bug did not effect the results at all.
1773
1774 - sponde: Added a new tab showing the effective collection area after
1775 trigger (including the software trigger)
1776
1777 - sponde: MMcSpectrumWeight has a new option which allows to define
1778 the scaling factor not by the integral of the events but at
1779 a defined energy:
1780 e.g. MMcSpectrumWeight.NormEnergy: 200
1781
1782 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1783 eventloops the loop could be accelerated by ~20%
1784
1785
1786
1787 *** Version 0.9.5 (2006/03/13)
1788
1789 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1790 and added the standard Disp-parametrization
1791
1792 - macros: added a new macro datacenter/macros/plotstat.C allowing
1793 to plot statistics about the data processing
1794
1795 - macros: added a new macro to plot the muon correction coefficients
1796 versus period (macros/plot/mucal.C)
1797
1798 - showplot: path inflation for ganymed files was broken
1799
1800 - callisto: Fixed an important bug. When the number of saturating pixels
1801 were calculated the bad pixel information already available from the
1802 calibration was ignored. This yields wrong values in case pixels
1803 are broken and saturate all the time or randomly.
1804
1805 - callisto: Updated Muon calibration constants. Spline data now also uses
1806 different values for different periods
1807
1808 - star: The time-evolution shown in the effective on-time plot now displays
1809 the axis range (if there are no holes it should be similar to the
1810 effective on-time)
1811
1812 - star: Added two new image parameters:
1813 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1814 the three pixels next to the center of gravity and the size
1815 + MNewImagePar.fConcCore: The ratio of the signals of all
1816 pixels inside or touching the ellipse and the size
1817
1818 - ganymed: now stops in requested source isn't found in catalog file
1819
1820 - ganymed: Many improvements to the phi-plot in wobble mode:
1821 + with a template the ideal background is displayed
1822 + a possible camera inhomogeneity is taken into account
1823 + the anti theta cut is better supported
1824 + the phi cut is automatically calculated from the theta cut
1825 See the examples in ganymed_wobble.rc for more details.
1826
1827 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1828 times the bin-width instead of the absolute energy
1829
1830 - ganymed: New cuts for on/off and wobble mode
1831
1832 - ganymed: The smearing of the False Source plot has been increased
1833 to 0.06
1834
1835 - ganymed: The starguider calibration can now be changed from the
1836 resource file.
1837 See the examples in ganymed*.rc for more details.
1838
1839 - ganymed: added a new option for on-/off-observations
1840 MJCut.RandomSourcePosition
1841 If switched on the distribution of observation time of the source
1842 position in the camera is calculated from the on-data and randomly
1843 applied with this distrbution to the off-data.
1844
1845 - ganymed: by skipping some obsolete calles in the eventloop the
1846 first and second loop could be accelerated by ~20%
1847
1848 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1849 position in the off-data randomly according to its distribution in the
1850 on-data.
1851
1852
1853
1854 *** Version 0.9.4.3 (2006/02/13)
1855
1856 - general: Fixed a bug in most of the programs which prevented the
1857 compile date in the startup message to be displayed
1858
1859 - general: Simplified program calls. The following abbreviations
1860 are now possible:
1861 showlog callisto 55599
1862 showplot signal 55599
1863 star 55599
1864 callisto 55999
1865 ganymed 2
1866 In this cases the corrsponding root-, log-, sequence- or dataset-
1867 filename is automatically compiled using the default datacenter
1868 paths ("/magic/*")
1869
1870 - general: Fixed a long outstanding bug which made axis tick marks
1871 disappear if MDataFormula was used (eg. abs(x))
1872
1873 - general: Updated MMath with new functions to calculate the results of
1874 a exponential, logarithmic and powerlaw fits analytically.
1875
1876 - general: Updated some macros with comments:
1877 + macros/optim/optimdisp.C
1878 + macros/optim/optimenergy.C
1879 + macros/optim/optimwobble.C:
1880
1881 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1882 files) now allows adding a pre-cut like in the optimization. E.g. this
1883 is useful to perform g/h-separation cuts before training the random
1884 forest.
1885
1886 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1887 correctly assigned in the raw data assignement table. A fix to correct
1888 the assignment tabel have been implemented.
1889
1890 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1891 by 90, 180 and 270 deg.
1892
1893 - general: the macro plotdb.C now allows to highlight sequences belonging
1894 to a datset. For more details see the descritions in the macro.
1895
1896 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1897 of the display, it gave wrong results espacially for big sizes.
1898 Now the embedded canvas should always have a ratio width/height=3/2.
1899 The "Size" options have been updated with values fitting the 3/2
1900 size ratio.
1901
1902 - RanForest:
1903 + Updated the random forest classes to support also the
1904 regression method implemented by Thomas H.
1905 + added new tutorial macro how to train the random forest
1906 for energy estimation (macros/optim/rfenergyest.C)
1907 + new classes to train the random forest (still in development)
1908 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1909 + new tutorial macros for random forest training in macros/train
1910 trainenergy.C, traindisp.C, trainseparation.C
1911
1912 - mars: now allows to setup a cut in the resource file mars.rc to choose
1913 the events to be displayed, eg:
1914 Cut.Condition: {0} && {1}
1915 Cut.0: MHillas.fSize>100
1916 Cut.1: MHillas.fSize<900
1917
1918 - merpp: Made aware of the new .rep format 200510250. This includes
1919 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1920 the discriminator thresholds (MCameraTD) and the disciminator
1921 delays (MCameraTD). All of them come with the CC report and are therefor
1922 written to the CC tree.
1923
1924 - callisto: fixed a bug in the calculation of the arrival times in
1925 the Digital Filter. They were all shifted by the same amount
1926 fHiGainFirst. This caused an offset in the order of the position of
1927 the left border of the extraction window in the times calculated
1928 from high-gain and from low-gain. The bug effected only the absolute
1929 arrival times. The bug was there since 30.1.2005.
1930
1931 - callisto: Changed the ExtractionWindow for the pulse position check
1932 such that the camera inhomogeneity becomes as less as possible and
1933 comparable to the pulso position check switched off. More details
1934 on the study will be given at our result web-page.
1935
1936 - ganymed: ganymed.rc, ganymed_onoff.rc:
1937 changed to new cuts trained with 1ES1218 and Crab-data
1938 for maximum sigma*log10(excess)
1939
1940 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1941 a new option was implemented to estimate Disp (CalcDisp)
1942
1943 - ganymed: Implemented two new options which allow
1944 to overwrite the default path to search for the sequence files
1945 --ins=/magic/sequences
1946 and where to search for the image data
1947 --ind=/magic/data/star
1948
1949 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1950 dx/dy from the resource file by
1951 MSrcPosCorrect.Dx
1952 MSrcPosCorrect.Dy
1953
1954 - ganymed: fixed reading the source catalog. Only as many chars
1955 as the requested source name had were compared (If a source
1956 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1957 were requested it could happen that the coordinates of
1958 "1ES1218" were read) The source coordinates are now printed
1959 in addition to its name to the logging output.
1960
1961 - ganymed: changed the background fit in the case of a ThetaSq function
1962 from a polynomial to a exponential, this should give a big improvement
1963 for on-only analysis'
1964
1965 - ganymed/sponde: Calculation of the error of single size-/energy-
1966 bins now uses Li/Ma (5) instead of LiMa (17)
1967
1968 - sponde: Added a plot E^2*dN/dE
1969
1970 - sponde: The energy estimator plot should now show values like
1971 they are commonly used.
1972
1973 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1974 (a powerlaw with cutoff didn't work before)
1975
1976
1977
1978 *** Version 0.9.4.2 (2005/10/01)
1979
1980 - general: added new tutorial macro macros/tutorials/threshold.C:
1981 how to calculate the threshold
1982
1983 - general: added a new game. Start it from the interpreter with
1984 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1985 and MagicReversi)
1986
1987 - general: neighbor pixels in MGeoms are now sorted clockwise
1988
1989 - merpp: made aware of new format 20050829-0
1990
1991 - callisto: New scale factors from muon analysis, stored in new
1992 resource file resources/calibration.rc
1993
1994 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1995 the eventloop if something went wrong. This is necessary for the
1996 automatic processing
1997
1998 - callisto: Implemented a new treatment for the time information
1999 developed by S.Ruegamer, this should give much better response than
2000 the old very primitive algorithm. This is especially important
2001 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
2002 treatment was buggy! As neighbor pixels to interpolate the
2003 arrival times always the pixels 0 to 5 were taken)
2004
2005 - callisto: In addition to the new treatment of arrival times the
2006 decision of the treatment whether a pixel contains shower
2007 information or not is used to improve the signal interpolation
2008 further. Previously interpolated pixels showed a non-zero signal
2009 do the peak searching signal extractors. Having a signal pixel
2010 beside raised the signal above the cleaning level. Thus the
2011 pixel survived cleaning to often but with a too low mean signal.
2012 By replacing empty pixels with a gaus (mean and rms from the
2013 corresponding Area entries in MPedPhotCam) this effect can
2014 be supressed.
2015
2016 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
2017 got lost when the events were stored by the calibration... fixed.
2018 (This was no problem for normal image cleaning because the pixel
2019 content was artificially set to 0 not surviving standard cleaning
2020 algorithm)
2021
2022 - callisto: Fixed a bug which caused the random and peak-search pedestal
2023 extracted with an extractor to be exchanged for the first (roughly)
2024 500 events (*Extractor and *ExtractorRndm).
2025 (They were simply exchanged in callisto.cc) This bug might have been
2026 introduced in Mars 0.9.4 when the order of calculation of the two
2027 types of pedestal in callisto got exchanged. The bug only effects
2028 the first seconds of data of each sequence.
2029
2030 - star: Taking the arrival time of Muons into account the calculation
2031 of the parameters could be made independant of the noise
2032 (pedestal rms). The dependance was due to the bias of the peak search
2033 extractor. Now only a ZA dependamcy is left which is not yet fully
2034 understood.
2035
2036 - ganymed: The sequences were still not sorted correctly in any case,
2037 because they were sorted by the full qualified path name. Now they
2038 are sorted by their sequence number.
2039
2040 - ganymed: new values for the spark-event-cut
2041
2042 - sponde: required missing MEnergyEst from ganymed.root... fixed.
2043
2044
2045
2046 *** Version 0.9.4.1 (2005/08/18)
2047
2048 - callisto: fixed some problems with the calibration in case of
2049 inteleaved events. Therefor the final and some intermediate
2050 fits are skipped which would take place on partly filled #
2051 histograms and gave wrong results or failed completely.
2052
2053 - callisto: If the intermediate finalization of the histograms
2054 calculating the mean charge of the calibration signal fails
2055 it is counted now and printed in PostProcess of MCalibCalcFromPast.
2056
2057 - ganymed: Fixed some bugs which caused problems in On-only mode.
2058 Still the false source plot doesn't give reasonable results.
2059
2060
2061
2062 *** Version 0.9.4 (2005/08/05)
2063
2064 - general: Fixed the ZA binning. It did not correctly fit the
2065 MC binning
2066
2067 - general: Added a class to correct for the missfocussing in
2068 April (MSrcPosCorrect)
2069
2070 - general: Random Forest energy estimator should now work properly
2071
2072 - general: MHCamera now displays the profiles in deg instead of mm
2073
2074 - general: MH::SetPalette offers a lot of new palettes
2075
2076 - general: MHillas - the case of CorrXY==0 is now handled properly
2077
2078 - general: implemented the possibility to change the line and
2079 marker style of a sky-grid drawn by MAstroCatalog
2080
2081 - general: Runs in sequences and datasets are now automatically
2082 ordered (it is assumed that the order of their filenames correctly
2083 represents the order of observations) to ensure correct reading
2084 of the subsystem data
2085
2086 - general: Runs cannot be added to a sequence twice anymore. Also
2087 Sequences cannot be added twice anymore to a dataset.
2088
2089 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2090 It gave wrong results by 1./2pi
2091
2092 - showplot: got a new option to start a root interpreter, too
2093
2094 - mars: now displays a rough estimate of Disp and the third moment
2095
2096 - mars: now displays the event time MTime if available
2097
2098 - mars: show muon parameters graphically
2099
2100 - mars: now the file to open can be given as commandline
2101 argument
2102
2103 - merpp: Added support for new arehucas version >= 200507190
2104 implementing values for three temperature sensors in the
2105 counting house (MCameraAUX) and the name of the HV settings file
2106 (MCameraHV).
2107
2108 - merrp: Also fixed some problems with wrong versions numbers stated
2109 by arehucas and implemented some fixed for old versions (<200407070)
2110
2111 - callisto: MCalibrationHiLoCam can now be printed from its context
2112 menu, eg in the TBrowser
2113
2114 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2115 - 1.39 (MExtractTimeAndChargeSpline)
2116 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2117 This is important mainly for timing studies.
2118
2119 - callisto: Changed limits in MHCalibrationChargeCalc from
2120 - -100.125 to -98 (fgChargeHiGainFirst)
2121 - 1899.875 to 1902. (fgChargeHiGainLast)
2122 - -100.25 to -99 (fgChargeLoGainFirst)
2123 - 899.75 to 901. (fgChargeLoGainLast)
2124 Introduced new limits:
2125 - fgNumLoGainBlackoutLimit: 0.05
2126 - fgLoGainBlackoutLimit: 3.5
2127 - fgLoGainPickupLimit: 3.5
2128
2129 - callisto: The handling of automatic weights for the digital filter
2130 has been improved. There are now new calibration weights special
2131 for Monte Carlo calibrations.
2132
2133 - callisto: Updated Muon scale with latest results (1% difference
2134 for most data, 5% for Mar/Apr'05)
2135
2136 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2137 was saturated and the blackout-events in the low-gain exceed the
2138 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2139 This excludes those pixels which have a saturating high-gain
2140 channel, but the low-gain switch does not switch often enough
2141 to make the distribution reliable.
2142
2143 - callisto: fix a bug counting the number of saturated events. Up to now,
2144 the number of saturated slices was counted (which is one for a not too
2145 high number), but for some (pathological) pixels, many more slices
2146 saturated and produced wrong limits.
2147
2148 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2149 + MCalibrationRelTimeCam.CheckFitResults: Yes
2150 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2151 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2152 + MCalibrationRelTimeCam.CheckOscillations: Yes
2153
2154 - callisto: introduce max. number of events for intercalibration,
2155 the rest gets skipped. Default: 4096
2156 The calibration causes too many un-reliable pixels if more
2157 than about 5000 events are treated (@500 Hz) because of the
2158 mode hopping of the VCSels. However, in the past, some
2159 calibration runs have been taken (erroneously) with more
2160 than 5000 events, especially the intensity scans where
2161 a good precision is needed.
2162
2163 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2164 photo-electrons for the spline extractor by 1-2% (correctly).
2165
2166 - callisto: The intercalibration is now done using a full f-factor
2167 method instead of a simple update. This makes things slower but
2168 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2169 changes.
2170
2171 - callisto: MPedestalY3 now uses the same extraction range as the data
2172 as calculated by MPedestalY2
2173
2174 - callisto: A check of the fraction of allowed unsuitable (10%) and
2175 unreliable (30%) pixels has been addded when the conversion is
2176 calculated from interleaved events
2177
2178 - star: fixed a bug which caused MEffectiveOnTime containers not to
2179 be written. In the worst case they were skipped almost all, in the
2180 best case they were all ok. It depends on how often the new value
2181 was assigned just with an event which was skipped later by another
2182 task
2183
2184 - star: new histograms MHPointing and MHRate
2185
2186 - star: New tab (Currents) displaying the time evolution of the mean
2187 DC currents
2188
2189 - star: New tab (MeanRms) displaying the time volution of the mean
2190 Pedestal Rms
2191
2192 - star: Output now contains MReportStarguider
2193
2194 - star: Improved muon analysis. Due to the absense of a constant
2195 for the gaus fit for arc width and the fact that the arcwidth
2196 plot was a histogram instead of a profile the resulting psf
2197 became pedestal rms dependant
2198
2199 - ganymed: added new plot (MHPhi) for wobble mode as described in
2200 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2201
2202 - ganymed: corrects now (correctly?) for the misspointing in
2203 May/April 05
2204
2205 - ganymed: Two new default templates for ganymed.rc are avilable:
2206 ganymed_onoff.rc and ganymed_wobble.rc
2207
2208 - ganymed: The first version of MFMagicCuts has been released
2209
2210 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2211
2212 - ganymed, sponde: There are two new options to determin the number
2213 of bins for the signal region (NumBinsSignal) and the number of
2214 total bins (NumBinsTotal) in the MHThetaSq histogram
2215
2216 - ganymed: optimized palettes for MHDisp
2217
2218 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2219 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2220 sqrt(2) to large
2221
2222 - ganymed: The false source plot (MHDisp) is now based on Disp
2223 and a background model determined in the first loop is
2224 subtracted
2225
2226 - ganymed: MFMagicCuts are now available in the cvs. The correct
2227 solution for the disp ambiguity problem is now calculated using
2228 the third moment. The third moment cut therefor is skipped.
2229
2230 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2231 already determined by the third moment along the major axis and
2232 so its actual sign is aligned along the major axis of the shower.
2233
2234 - ganymed: If starguider data is available it is taken into account
2235 when calculating the source position. This is especially important
2236 for wobble data at high zenith angles and culmination data.
2237
2238 - ganymed: If available the starguider data is taken into account as
2239 good as it is possible without a starguider calibration. To switch
2240 it off add
2241 MPointingDevCalc.MaxAbsDev: -1
2242 to your ganymed.rc
2243
2244 - sponde: the zenith angle distribution is now weighted instead of
2245 choosen by default. This gurantees higher statistics in the highest
2246 and lowest energy bins. To switch this behaviour off use...
2247
2248 - sponde: now automatically displays the energy threshold
2249
2250
2251
2252 *** Version 0.9.3 (2005/06/03)
2253
2254 - general: MMcEvt now derived from MMcEvtBasic which should
2255 have no influence on compatibility with older camera files
2256
2257 - general: Implemented a new option to MReadReports which allows
2258 to force reading of the first event of some trees (eg. Drive-tree)
2259 before any other tree.
2260
2261 - general: Made a fix to MPointingPosCalc which assumes that the
2262 run-type is real-data if Process is called before ReInit, such
2263 that also the very first Drive-events in a run are treated
2264 correctly.
2265
2266 - shoplot now displays the filename in the title bar of the window
2267
2268 - merpp: new options: --auto-time-start --auto-time-stop which
2269 allow to cut updating with slow-control at the start- or
2270 (previousle --auto-time only allowed: and) stop-time of
2271 the run stored in the runheader.
2272
2273 - callisto: changed default of fgFallTimeHiGain in
2274 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2275 already set as default in callisto_Dec04Jan05.rc
2276
2277 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2278 now changes the filename for new weights automatically for
2279 cosmics, MC and for different calibration colors.
2280
2281 - callisto: a problem with the order of some code cause the
2282 name of the weights file in MPedestalY2 to be ignored.
2283 Wrongly the calibration_UV weights were used instead
2284 of the cosmics weights set in callisto.rc.
2285
2286 - callisto: should allow ct1 pulser data when the color is
2287 explicitly set also for pretty new runs
2288
2289 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2290 to introduce an additional scale factor (should be around 1)
2291 to adapt for slight deviations in different extractors from
2292 the MC calibration. For MC calibrations the scale factor
2293 is fixed to 1
2294
2295 - callisto: MFCosmics should handle very high signals a bit
2296 more accurate now
2297
2298 - callisto: when calculating the mean pedestal rms for different
2299 pixel sizes or sectors also kUnsuitableEvt is now taken into
2300 account - not only kUnsuitableRun
2301
2302 - callisto: '-raw' option is now the default
2303
2304 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2305 This has the advantage that mean values in the calibration (eg
2306 arrival times) are calculated more accuratly.
2307
2308 - callisto: In the resource file callisto_Dec04Jan05.rc
2309 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2310
2311 - callisto: new Hi-/Lo-Gain intercalibration constants
2312 hilocalib_sp1.root and hilocalib_sp1_mc.root
2313
2314 - callisto: changed default for MJPedestalY2.MaxEvents
2315 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2316
2317 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2318 has changed from 9.0 to 6.0. This is necessary to exclude two very
2319 ringing pixels in September which - when kept - destroy the image
2320 cleaning around them (Markus G.)
2321
2322 - callisto: (!) The Muon analysis of all data taken so far has
2323 suggested that different extractors give slightly different
2324 absolute results after calibration, due to there different
2325 handling of the calibration- and cosmics pulse shape. Although
2326 the over all calibration seems to be a bit to pesimistic (or
2327 the MC seems to be a little bit - 3-5% - too much attenuated).
2328 There for correction factors have been introduced which correct
2329 the calibration constants by
2330 0.956937799 for Digital Filter (callisto.rc)
2331 and
2332 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2333 calibration. The main advantage is, that both data types can
2334 be easily analysed together and compared to the same MC sample.
2335 The factors are choosen such, that the reference is now a
2336 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2337
2338 - star: fixed a bug which caused the first bin of the histograms
2339 vs time to disapear in PostProcess. This gave wrong results
2340 on the screen. The output and all following programs not
2341 directly accessing the histograms haven't been affected
2342
2343 - star, ganymed: Made sure that always the first Drive-tree event
2344 is read and Processed before the first data event was read.
2345
2346 - ganymed: implemented the possibility to replace the standard
2347 false source plot with a different one. For example: If
2348 you want to use a Disp based FS plot use the resource:
2349 NameHistFS: MHDisp
2350 For details about the requirements of these plots look
2351 at the corresponding classes
2352
2353 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2354 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2355 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2356 case MAlphaFitter is setup correctly. For On-Only optimization
2357 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2358 RunOn() instead of Run(). For energy estimation MJOptimize
2359 has been replaced by MJOptimizeEnergy
2360
2361 - sponde: The input MC spectrum can now be weighted to fake a
2362 different spectrum. This is done via MMcSpectrumWeight. For
2363 more details see the class description and sponde.rc
2364
2365 - sponde: The paremeter comparsion plots are not scaled by
2366 their entries anymore. Instead the MC plot is scaled by using
2367 the result spectrum of the analysis. If the input MC spectrum
2368 and the result spectrum has different slopes the absolut
2369 normalization is normally wrong.
2370
2371
2372
2373 *** Version 0.9.2 (2005/05/20)
2374
2375 - general: Changed the default paths for calibrated data and image
2376 files. (The implemented access to these files doesn't yet exist)
2377
2378 - general: support for MRunIter has been removed from the job classes
2379 (use the setter functions of MSeqeunce instead)
2380
2381 - general: ProcessFile has been renamed to Process in all job classes,
2382 because ProcessFile is missleading
2383
2384 - general: The storage of the palette in MHCamera is now possible
2385
2386 - general: new bits describing unsuitable and unreliable pixels have
2387 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2388 kDeadPedestalRms, kFluctuatingArrivalTimes
2389
2390 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2391 versions newer than V200404070
2392
2393 - general: support for cc file versions newer than V200504130. Added
2394 support for active loads (MCameraActiveLoad) and central pixel
2395 (MCameraCentralPixel)
2396
2397 - general: added new histograms for image parameters versus size
2398 (MHVsSize)
2399
2400 - general: The eventloop now automatically calls PrintStatistics
2401
2402 - Status Display: Improved support for printing:
2403 + A default can now be set in .rootrc (for more details see
2404 MStatusDisplay::PrintPS)
2405 + A print dialog is opened so that printer and command line
2406 can be canged
2407
2408 - showlog: improved such that it handles different verbosity levels
2409 more accurate now. This mean you can suppress output when
2410 using showlog.
2411
2412 - showplot: improved
2413 + The new graphics formats have been implemented
2414 (pdf, svg, png, jpg and xpm)
2415 + Implemented an interface for printing. Because you can change
2416 the printing command from the command line you can use all
2417 the nice postscript tool. To print a booklet for example call:
2418 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2419 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2420 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2421
2422 - callisto: fixed a bug in the recognition of the calibration bit
2423 pattern. Concerns only intensity calibration. (The strength of the
2424 intensity has been updated in some cases)
2425
2426 - callisto: add a filter against PIN Diode events when running over
2427 calibration runs since some of the recent calibration runs have
2428 been taken with Pin Diode.
2429
2430 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2431 39943, 44833 in the calibration (MCalibColorSet)
2432
2433 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2434 been set to 1e-18 in callisto_Dec04_Jan05.rc
2435
2436 - callisto: in callisto_Dec04Jan05.rc: set value for
2437 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2438 statistics for the calculation of the mean pulse time
2439 of the cosmisc
2440
2441 - callisto: the charge limit in the calibration has been raised
2442 from 2.5 to 4.5
2443
2444 - callisto: new setup read from callisto.rc
2445 + MCalibCalcFromPast.fNumEventsDump
2446 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2447 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2448
2449 - callisto: MExtractTimeAndChargeSpline extractor:
2450 + The integration ranges were shifted by 0.2 FADC slices to the right.
2451 + unreliable handling of floating point values caused different
2452 results on different platform or with different compiler options:
2453 The new algorithm is numerically exact and more accurate because
2454 it doesn't calculate the integration position by multiple times
2455 adding the step-size (which results in numerical uncertanties
2456 exspecially if multiplied with large numbers)
2457 + A lot of fixes have been introduced which effects integrating the
2458 spline at the edges of the valid range. In this case any memory
2459 was randomly accessed. This behaviour can be tested replacing
2460 all MArrayF by TArrayF which perform a range check (but of course
2461 they are a lot slower)
2462 ! No result obtained with the Spline before can be trusted! Due to
2463 random memory access it might by completely random!
2464
2465 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2466 + extraction range in the high gain to 4.
2467 + weights file to cosmics_weights46.dat
2468
2469 - callisto:
2470 + introduce the check for fluctuating arrival times.
2471 + set charge limit to from 2.5 to 4.5
2472 + introduce asymmetric exclusion due to "deviating number of phes":
2473 Default: -9.0 +4.5
2474 + make deviating number of phes unsuitable (see David's findings).
2475
2476 - callisto: fixed the display of unsuitable pixels. The old change
2477 to a real profile in MHCamera broke it.
2478
2479 - callisto: The cosmics filter is used in MJCalibration now
2480 independant of the pulser color (formaly it was used only for
2481 CT1-pulser data). The threshold of number of max empty pixels
2482 has been raised from 2% to 5% in MJCalibration. The maximum
2483 fraction of rejected event is 50% otherwise the calibration has
2484 failed. The filter now ignores unsuitable pixels.
2485 Setup the filter from callisto.rc using "ContCosmics"
2486 (see MFCosmics::ReadEnv)
2487
2488 - callisto: changed default for fgOffsetFromLogain back
2489 from -2.8 to -1.8 in digital filter.
2490
2491 - callisto: for the common extractors
2492 + MExtractFixedWindow
2493 * MExtractTimeAndChargeSlidingWindow
2494 * MExtractTimeAndChargeSpline
2495 * MExtractTimeAndChargeDigitalFilter
2496 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2497 and fResolutionPerPheLoGain
2498
2499 - callisto: Updated the hi-/lo-gain intercalibration constants
2500 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2501 hilocalib_df6.root
2502
2503 - callisto: The default lo-gain extraction window for the
2504 MExtractTimeAndChargeSlidingWindow extractor has been increased
2505 from 6 to 8 to take the stretch of the pusle into account
2506
2507 - callisto (!!!): fixed an important bug in the setting of the
2508 incoming pedestal pointer to the signal extractor extracting
2509 pedestals. This bug caused the pedestals not to be subtracted
2510 correctly in the calibration afterwards. The effect was about 10%
2511 too high conversion factors for the digital filter and the spline
2512 and more than 40% for the sliding window.
2513 The bug existed since end of February! (Markus G.)
2514
2515 - star: added muon support to star. A new tab "MHMuonPar" is
2516 displayed. The lower right plot is an estimate of the point spread
2517 function. A reference value is displayed. To get the real PSF
2518 you must compare with MC. The setup for the muon analysis
2519 is done in star.rc. More informations can be found in
2520 MHSingleMuon and MHCalibParCalc
2521
2522 - star: The weather data is now displayed in star
2523
2524 - star: MEventRateCalc handles the calculation of the event rate more
2525 accurate now in case of the start of a new run inside a sequence
2526
2527 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2528 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2529 changed only minimally
2530
2531 - ganymed: (MJCut and MJOptimize) now displayes the number of
2532 excess events versus size. The energy estimation is done in
2533 MJSpectrum (sponde)
2534
2535 - ganymed: got support for using other variables than Alpha, eg. Theta.
2536 Therefor you need a class deriving from MHAlpha which supports
2537 this variable (one is already existing: MHTheta, which is now the
2538 default in ganymed). It is setup through ganymed.rc
2539
2540 - added a full featured spectrum program (sponde) which reads
2541 ganymed output and monte carlos and compiles a spectrum
2542
2543
2544
2545 *** Version 0.9.1 (2005/04/14)
2546
2547 - Fix bug on the arrival time reconstruction when using Digital
2548 Filter (in some marginal cases (10%) times were reconstructed shifted
2549 by 0.2 slices)
2550
2551 - all executables now return 2 where in previous versions -1 has
2552 been returned (gave problems with shell-scripts)
2553
2554 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2555 also done with a intercalibration input file
2556
2557 - a bug in the time fine adjustment of the digital filter has been fixed
2558
2559 - a lot of small fixes to calling TPad::Divide with a margin==0
2560
2561 - MStatusDisplay now shows the memory usage
2562
2563 - added a memory leak statistic after the eventloop
2564
2565 - MHadronness replaced by MParameterD
2566
2567 - MEnergyEst replaced by MParameterD
2568
2569 - wobble mode can now be switched on from the data-set
2570
2571 - switched on bad pixel detection for a pedestal level
2572 which is more than 5 times the variance
2573
2574 - Fixed default paths to be correct for the new data center
2575
2576 - Fixed handling of drive data. The pointing position in now
2577 copied to MPointingPos inside star for real and MC events
2578
2579 - made sure, that the sequences in a dataset are sorted by
2580 their number to ensure the correct synchronization
2581
2582 - added all resource files necessary to handle spline extraction
2583 of signal for the late 2004 and the early 2005 data
2584
2585 - update the reference lines for the december data
2586
2587 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2588 This is important for the Dec. and Jan. data where the calibration
2589 pulse position changes much.
2590
2591 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2592 filter. This corrects only an defective extraction of the MC at
2593 low-gain signals lower than 90 phes.
2594
2595 - fixed some slowdown in calibrating data with interleaved events from
2596 Jan and Dec. As a workaround made the pretty palette the default.
2597 The inverse Deep Blue Sea has a bug which slows down long calibration
2598 runs a lot.
2599
2600 - implemented new values from new starguider report as defined
2601 in TDAS00-07 V7.1 (eg SkyBrighness)
2602
2603 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2604 in starguider report (If you merpp the same reports with this version
2605 you'll get the correct units (arcmin) but a different result
2606 than with old versions (wrong units))
2607
2608 - Now the status display can also write PNG, JPEG and XPM (other file
2609 formats are still unsupported by root)
2610
2611 - added a lot of scripts and macros in directory datacenter used
2612 for automatic processing
2613
2614
2615
2616 *** Version 0.9 (2005/03/23)
2617
2618 - Calibration is now done autmatically into photo-electrons like
2619 decided by the Collaboration Board
2620
2621 - Reference lines in the display can be read from resource file
2622
2623 - Interlaced calibration events can be handled by callisto
2624
2625 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2626 and applied in callisto.
2627
2628 - class MJCalibTest can be called by callisto
2629
2630 - callisto can now run with three data types: rawdata, rootdata, MC
2631
2632 - added two classes mreport/MReportStarguider.cc and
2633 mreport/MReportStarguider.h for implementing starguider-data
2634
2635 - the output of merpp-update now contains starguider information:
2636 MReportStarguider and MTimeStarguider
2637
2638 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2639 values were lower than they should. This was more visible for high
2640 energy (Size) events.
2641
2642 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2643
2644 - added a new loop to callisto to support the correct extraction of
2645 the pedestal and pedestal rms through the signal extractor
2646
2647 - added class to perform fourier tranformation of a hexagonal structure
2648 (MHexagonalFT)
2649
2650 - added class to perform fourier tranformation of a hexagonal structure
2651 in a tasklist (MHexagonalFTCalc) example: hft.C
2652
2653 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2654 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2655 small pixels, example: extendcam.C
2656
2657 - added possibility to write data to memory (TTree) using MWriteRootFile
2658
2659 - added possibility to read a TTree stored only in memory by MReadTree
2660
2661 - new classes to deal with the interleaved calibration events:
2662 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2663
2664 - implemented filters to callisto to skip calibration events
2665
2666 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2667 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2668 the slices by statistics
2669 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2670 signal extractor without randomization
2671 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2672 with the signal extractor with randomization (extraction window is
2673 randomly fixed)
2674 The three kind of pedestal is not yet implemented (for speed reasons) as
2675 long as nobody really needs it:
2676 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2677 extracted with the signal extractor with randomization
2678
2679 - callisto now finds the pulse position in the data automatically
2680
2681 - implemented data reduction in calibrated data by reducing the precision
2682 of the stored floating point values (pedestal, rms and signal) to
2683 roughly 0.5%
2684
2685 - fixed showplot to make file format conversion (eg. converting a
2686 status display stored in a root file into a postscript file) in
2687 batch mode possible:
2688 showplot -b --save-as-ps[=outfile.ps] infile.root
2689
2690 - Allow class names as part of filter rules, eg
2691 (MFSupercuts) && (MHillas.fSize>100)
2692
2693 - fixed a lot of stuff to allow all programs to process MonteCarlo
2694 camera files.
2695
2696 - enhanced possibility to debug reading of resource file
2697
2698 - MDataChain should handle priorities of operator more
2699 accurate now
2700
2701 - completely revised the container in which the signal is stored
2702 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2703 * the new implementation is faster and
2704 * needs less storage space
2705
2706 - FIRST version which can process Monte Carlos through the
2707 whole chain of programs (callisto, star, etc)
2708
2709 - implemented new image parameters for the border length of
2710 the shower image (MNewImagePar2)
2711
2712 - implemented wobble-mode in ganymed
2713
2714 - new class (MJOptimize) taking care of all optimization processes
2715
2716
2717
2718 *** Version 0.8.6 (2004/10/05)
2719
2720 - New combined signal and time extractor
2721 MExtractTimeAndChargeDigitalFilter
2722
2723 - The Report for the trigger section in the CC run summary has been
2724 updated, and now the IPRs (Individual Pixel Rates) are available.
2725
2726 - new macros for database interaction: filldotrun.C, filldotrbk.C
2727
2728 - added new program which can convert colored output which was redirected
2729 into a file back into colored text (for example to display it with
2730 more): showlog
2731
2732 - added new program to display an MStatusArray of plots (stored with
2733 MStatusDisplay) from a file: showplot
2734
2735 - Added support for Sequences (MSequence). Sequences are blocks of run
2736 files containing the same calibration and belonging to the same
2737 source
2738
2739 - Added a new task (MTaskEnv) which can be used in setup files to switch
2740 between different tasks (for example to choose a signal extractor)
2741
2742 - Implemented automatic file splitting in MWriteRootFile
2743
2744 - After image cleaning an island index is assigned to all used pixels.
2745 The index corresponds to the order of the islands in size.
2746
2747 - added a cleaning which takes signal height _and_ arrival time into
2748 account: probability cleaning (for more details see MImgCleanStd)
2749
2750 - added a cleaning which takes takes the absolute number of photons
2751 times the area ratio as cleaning level
2752 (for more details see MImgCleanStd)
2753
2754 - Changed calculation of image parameters such, that it can be done
2755 for all used pixels or the pixels with a defined island index only
2756
2757 - implemented new image parameters displaying the number of islands,
2758 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2759
2760 - event display in executable changed to support also calibrated files
2761 (done with MJCalibrateSignal)
2762
2763 - added program doing the calibration and the signal extraction
2764 and signal calibration: callisto Most part of the setup is done
2765 by a resource file: callisto.rc
2766
2767 - implemented support for pixels with negative IDs (Raw file format
2768 version 4)
2769
2770 - implemented an new option in merpp (--auto-time) to get the time
2771 range for cc and/or caco data from the run header of the raw data
2772
2773 - New star-program (star and MJStar). Taking calibrated data from
2774 callisto/MJCalibrateSignal as input. The setup is done through
2775 a resource file: star.rc
2776
2777 - Added possibility to setup the eventloop in the mars-executable
2778 Camera Display by a resource file: mars.rc
2779
2780 - The the mars-executable Camera Display can now also read
2781 calibrated data files written by callisto/MJCalibrateSignal
2782
2783 - Added a new class which can calculate the source position in
2784 the camera from a pointing model known to be correct and
2785 the pointing model used for observations (MSrcPosFromModel)
2786
2787 - added a new version of the class calculating the effective on-time
2788 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2789 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2790 MHTimeDiffTheta.
2791
2792 - added the possibility to count how often a signal is above (or
2793 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2794 can replace MHTriggerLvl0)
2795
2796 - added ore convinient ways to set the axis-titles of your histograms
2797 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2798 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2799
2800
2801
2802 *** Version 0.8.5 (2004/08/06)
2803
2804 - new Signal Extractors: MExtractFixedWindowSpline
2805 and MExtractAmplitudeSpline
2806
2807 - implementes interleave in merpp to be able to merpp parts of a file
2808
2809 - implemented force-functionality to merpp
2810
2811 - star display to display star catalogs (MAstroCatalog)
2812
2813 - star display to 'mirror' stars to the camera (MAstroCamera)
2814
2815 - implemented a new cleaning option which allows cleaning scaled with
2816 the real ratio of the rms depending on the pixel size, not only the
2817 square root of the pixelsize (MImgCleanStd, MCameraData)
2818
2819 - removed obsolete MBlind* classes
2820
2821 - Signal extractor taking the AB flag into account implemented (this makes
2822 an odd number of slices for signal extraction possible
2823 (MExtractSignalABcorr)
2824
2825 - implemented a class extracting the pedestal from the raw-data (events)
2826 itself using empty lo-gain (MpedCalcFromLoGain)
2827
2828 - Added mean values to MPedPhotCam
2829
2830 - Added Makefile for Darwin (this OS is NOT officially supported!)
2831
2832
2833
2834 *** Version 0.8.4 (2004/04/19)
2835
2836 - new fast arrival time extractor using cubic splines:
2837 MExtractTimeFastSpline
2838
2839 - implementes multi-argument support in MDataChain
2840 ("pow(a, b)")
2841
2842 - implemented double reference support in MDataChain
2843 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2844
2845 - added support in MF for expressiond like
2846 "MHillas.fWidth<2*<MHillas.fLength"
2847
2848 - MDataChain is now able to support variables like [0], [1], ...
2849 which can be used in fit functions as parameters. The interface
2850 is implemented through the new virtual function
2851 MParContainer::SetVariables
2852
2853 - added new class MArrivalTimeCam/MArrivalTimePix:
2854 Storage containers to hold the ArrivalTime of the camera/pixel
2855
2856 - added new classes for the calibration of relative arrival times:
2857 MCalibrationRelTimePix and MCalibrationRelTimeCam
2858
2859 - added new classes to extract the signal of the blind pixel and the
2860 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2861
2862 - added new classes for the bad-pixels treatment (MBadPixels*)
2863 which are more powerfull than the old ones (MBlindPixel*)
2864 and will replace them.
2865
2866 - added filter against cosmics: MFCosmics
2867
2868 - added new class MArrivalTimeCalc2:
2869 Calculates the arrival time as the signal weighted mean of the time
2870 slices in the maximum window
2871
2872 - added a new macro call pointspreadfucntion.C that fits with a 2D
2873 gaussian the DC spot for an star. It gives you the RMS of
2874 the PSF and the center of the star, very useful for misspointing
2875 studies.
2876
2877 - added support for multi-telescope camera files. Added classes
2878 MStereoCalc and MStereoPar, classes to calculate and store shower
2879 parameters calculated from the data of two telescopes, for the MC
2880 studies regarding the MAGIC clone.
2881
2882 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2883 MC data calibrated in photons instead of ADC counts.
2884
2885 - added three macros to show the calibration and analysis chain of
2886 MC data. The macro starmc.C does both calibration and analysis, producing
2887 an output containing Hillas parameters for each event. The macro
2888 mccalibrate.C does just the calibration and writes out a file containing
2889 pixel information in photons instead of FADC data. The macro starmc2.C
2890 reads in such a file and produces an output with Hillas parameters.
2891
2892 - added MPedPhotCalc to compute pedestals in units of photons, see
2893 macro pedphotcalc.C
2894
2895 - added all class to perform the calibration, see macro calibration.C
2896
2897 - added class MFFT to perform Fast Fourier Transforms
2898
2899 - added class MSimulatedAnnealing to perform simulated annealing
2900 minimizations
2901
2902 - added new macro bootcampstandardanalysis.C which holds the skeleton
2903 of the analysis chain discussed in the december bootcamp.
2904
2905 - added support for DAQ raw data file format V2
2906
2907 - implemented an arbitrary time stamp for the events from raw-data
2908 files with file version<3. It is calculated from the run number,
2909 the date of start and the FADC clock tick from the first module
2910
2911 - implemented the correct decoding of the event time-stamp
2912 coming from the DAQ for raw-data files with file-version>2
2913
2914 - added a new classes storing the pedestals in units of photons:
2915 MPedPhotPix, MPedPhotCam
2916
2917 - added support for DC current files from the camera control
2918
2919 - added support for start- and stop-time when merpping report files
2920
2921 - added MReportCC storing the weather data from the CC-REPORT
2922
2923 - added class to fill trainings and test matrices (MTFillMatrix)
2924
2925 - added a filter performing a software trigger (MFSoftwareTrigger)
2926
2927 - Added classes to perform parts of the standard analysis (Jobs):
2928 + MJPedestals
2929 + MJCalibration
2930 + MJExtractSignal
2931 Note: All of them are preliminary!
2932
2933 - Added Iterator to iterate over files giving only the run-number
2934
2935 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2936 the evolution of a sector vs time
2937
2938
2939
2940 *** Version 0.8.3 (2003/12/05)
2941
2942 - adapted Random Forest classes to allow the use with MC
2943 multi-telescope files which can be produced with the coming
2944 camera version 0.7.
2945
2946 - added classes to read and interprete central control report files
2947 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2948
2949 - enhanced merpp (the executable) to support .raw and .rep files.
2950
2951 - added classes for light calibration (MCalibration* and
2952 MHCalibration*) by Markus Gaug. Further work has to be and will
2953 be done soon.
2954
2955 - Added a preliminary 'synchronizer' (MReadReports) which will
2956 replace MReadMarsFile as soon as it is finished.
2957
2958 - Added a tutorial macro demonstrating how report files are merpped
2959 and how they can be read from the root file in the correct order
2960 of time (readrep.C)
2961
2962 - Added a generalized histogram (similar to MH3) called MVsTime
2963 which allows to plot variables (or rules - MDataChain - of
2964 variables) vs time. For an example have a look at tempvstime.C.
2965
2966 - Changed the name of the event trees:
2967 + Events --> Events
2968 + PedEvents --> Pedestals
2969 + CalEvents --> Calibration
2970
2971 - changed name of MTime in the event trees from MRawEvtTime to MTime
2972
2973 - added displaying the sector indices to the mars event display
2974
2975 - Magic Online Analysis (MOnA) implemented in a first version
2976 (see mona.cc, MOnlineDump and MOnlineDisplay)
2977
2978 - added classes to calculate event rate
2979 (preliminary: MEventRateCalc, MEventRate)
2980
2981 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2982
2983 - added classes dealing with the telescope pointing position (MPointing*)
2984
2985 - implemented the 'final' Mars time stamp based on some experiences with
2986 the new 'Synchonizer'
2987
2988
2989
2990 *** Version 0.8.2 (2003/11/10)
2991
2992 - accelerated standard analysis by a factor of 6-8 ...
2993 + doing precalculations in MGeomCam for the pixel area ratio
2994 + creating a look up table for the single pixels in MCerPhotEvt
2995
2996 - added task to calculates weights in case you want to 'change'
2997 the energy spectrum of a monte carlo file
2998 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2999
3000 - added a new executable star which implements the
3001 star.C macro as precompiled executable. Currently a flexible
3002 setup is not possible, but a 'input card' setup will follow.
3003
3004 - Starting to implement Multi-Telescope-Support based on the
3005 upcomming camera version 0.7. The base for a general support
3006 is implemented and the star-functionality is proven to work.
3007
3008 - Replaced Event-Display in and Camera-Display in the Mars GUI
3009 executable by a more convinient display base on MStatusDisplay.
3010
3011 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
3012
3013
3014
3015 *** Version 0.8.1 (2003/10/20)
3016
3017 - added signal subtraction for pure on data by means of fitting
3018 the background in the off region or by performing a combined
3019 signal/background fit. Provides necessary histograms for
3020 obtaining energy spectra and a light curve.
3021
3022 - added classes to perform and study the selection of the
3023 2nd Level Trigger on MC data (example in triglvl2.C macro)
3024
3025 - added pedestal calculation
3026
3027 - implemented "democratic cleaning" (tail cut value proportional
3028 to pixel area) according to Wolfgang's suggestion.
3029
3030 - added Sigmabar treatment (calculation and basic histogramming)
3031
3032 - added basic routines to apply padding
3033
3034 - added first implementation of MARS-based source visibility plotter
3035 (needs to be linked against slalib, preliminary version)
3036
3037 - enhanced functionality of data chains: random numbers, conversion
3038 functions and access to MHMatrix objects
3039
3040 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
3041 numbers under certain circumstances (runs with 0 events included)
3042
3043 - fixed a bug in the general filter MF (didn't work on some systems
3044 at all)
3045
3046 - fixed a bug in chaining files, which caused the analysis to crash or
3047 ignore files
3048
3049 - implemented more geometry classes describing the parameters used
3050 to simulate the PMT camera
3051
3052 - added new Monte Carlo classes containing the setup of the different
3053 programs in the MC chain.
3054
3055 - added a (preliminary) general task to evaluate chi-square of a given
3056 parameter in an eventloop.
3057
3058 - first implementation of a container describing the observatory
3059 location (Long, Lat, etc)
3060
3061 - added Random Forest - method for g/h-separation
3062
3063 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3064 (this means, that it is compiling, but not yet fully tested)
3065
3066 - added a new status display which can show the present status
3067 of histograms while an eventloop is running (MStatusDisplay,
3068 an example can be found at status.C)
3069
3070 - reorganized directories:
3071 classes describing the image --> mimage
3072 classes containing Monte Carlo Histograms --> mhistmc
3073 classes for Random Forest method --> mranforest
3074
3075 - added (event-)weights to fill histograms
3076
3077 - colors in logging output to screen
3078
3079 - changes to the Image Parameter declaration:
3080 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3081 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3082 + MHillasExt now derives from MParContainer instead of MHillas
3083 --> Files written with the old definition are more or less unreadable
3084
3085 - reading of reflector files
3086
3087 - display data from reflector files in the camera
3088
3089 - implemented currents (and display them in the camera)
3090
3091 - logarithmic scale in camera
3092
3093 - added class to iterate through directory contents (MDirIter)
3094
3095
3096
3097 *** Version 0.8 (2002/11/18)
3098
3099 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3100
3101 - corrected 48(!) wrong entries in the Next Neighbor table of the
3102 Magic Camera (all in the inner part of the outer ring, mostly
3103 missing a single NN)
3104
3105 - Fixed a bug in the table describing the Next Neighbours of the
3106 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3107 have any neighbour)
3108
3109 - changed trigrate.C: now it calculates the pure NSB triggers from
3110 a camera file (generated with no showers), so there is no need
3111 to introduce them by hand in the BgR array (for more details
3112 please ask Abelardo)
3113
3114 - added MHHadronness (and MHadronness) as a general facility to evaluate
3115 the quality of a gamma-hadron seperation method
3116
3117 - changed MWriteAsciiFile to accept rules (MDataChain)
3118
3119 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3120 must be replaced by calles to MWriteAsciiFile::AddColumn and
3121 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3122 changed.
3123
3124 - Implemented generalized event-matrices (one row per event)
3125 (MHMatrix)
3126
3127 - implemented the one dimensional composite probabilities
3128 (MHCompProb, MCompProbCalc, comprob.C)
3129
3130 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3131 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3132
3133 - Added a camera display displaying the pixel numbers to the
3134 event display gui.
3135
3136 - Added Monte Carlo Informations to event display gui
3137
3138 - Changed the camera display to display the pixel numbering
3139
3140 - Added three buttons to the camera display to change the palette
3141
3142 - Added the number of used and core pixels after image cleaning
3143 to MHillas
3144
3145 - Changed the algorithm used in MHillas according to TDAS 02-03
3146
3147 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3148
3149 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3150
3151 - Added fCosDeltaAlpha to MHillasSrc
3152
3153 - The numbers of photons used to calculate fConc and fConc1 in
3154 MHillasExt are now scaled with the pixel size, so that one get
3155 a four times smaller value for the bigger pixels in the outer ring.
3156
3157 - added new task to smooth the camera contents (MCameraSmooth)
3158
3159 - added possibility to use interpolated pixel values for blind pixels
3160 instead of removing it completely from the analysis
3161
3162 - Implemented the possibility to save the whole eventloop with
3163 its setup to a file. This information can be read and from
3164 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3165 and MEvtLoop::MakeMacro. If you find something not working, please
3166 report - this stuff is still in a beta phase.
3167
3168 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3169 file having crab starfield, but also for all following files - fixed
3170
3171 - MTaskList::PrintStatistics can now be instructud to print also the
3172 title, too: use PrintStatistics(0, kTRUE)
3173
3174 - Changed the image cleaning so that pixels with to many 'used'
3175 neighbors are left used (to get rid of 'holes' in events)
3176
3177 - Introduced more output to the camera displays
3178
3179 - Added an array of histograms (eg one hist per run), MHArray
3180
3181 - Added a _preliminary_ version of the reader for CT1 PreProc files
3182 (MCT1ReadPreProc)
3183
3184 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3185 (thanks to Raquel)
3186
3187 - added the first energy estimator (MEnergyEstParam, estimate.C,
3188 estfit.C) using a parametrization
3189
3190 - Added some new Monte Carlo paremeter containers used to store
3191 setup information from the MC chain (MMcConfigRunHeader,
3192 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3193
3194
3195
3196 *** Version 0.7 (2002/04/30)
3197
3198 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3199 the pedestal mean value was saved incorrectly. For files from
3200 this versions we substract 0.5 from the pedestal mean.
3201 WARNING: This may effect your results, so don't wonder...
3202
3203 - First implementation of an algorithm using only triggered events
3204 for the collection area calculation
3205
3206 - Ascii Output can now also be used for parameter containers which
3207 doesn't overload MParCointainer::AsciiWrite
3208
3209 - The Ascii Output is now also capable of writing single data members
3210 of one container
3211
3212 - You are now able to change the order of the values written to the
3213 ascii file
3214
3215 - You can now specify a conversion factor for each data member written
3216 to an ascii file. This may be usefull to change the units of the
3217 data member (eg. degrees instead of millimeters in case of the
3218 hillas parameters)
3219
3220 - Replaced old MHillas by a new structure which allows you to extend
3221 the parameters stored in MHillas very easily:
3222 see MHillas and MHillasExt
3223
3224 - Added classes to handle source dependancy of image parameters:
3225 see MHillasSrc
3226
3227 - Added container (MBinning) to have a standard input for the binning
3228 in different histograms (eg. the Energy bins should be the same in
3229 all histograms)
3230
3231 - Changed Hillas histograms from mm to deg
3232
3233 - Added the flexible binning to the hillas histograms
3234
3235 - Added a filter for the alpha parameter (MFAlpha)
3236
3237 - It is now possible to write single data members of a class object to
3238 an output stream instead of the whole container only
3239
3240 - Added a generalized filter for a data member:
3241 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3242
3243 - Added a generalized Filter parser for more difficult filter rules
3244 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3245
3246 - Added new Monte Carlo histograms:
3247 MHMcEnergyImpact and MHMcEfficiency
3248
3249 - Added many new histograms needed for the flux calculation.
3250
3251 - Added a generalized histograms which can fill and show up to three
3252 data members in either a one-, two- or three-dimensional histogram, eg:
3253 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3254
3255 - Added:
3256 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3257 * calculation of <Theta> as a function of time (MHThetabarTime)
3258 they are needed in the flux calculation in
3259 order to select for a given bin in Theta (or time) the appropriate
3260 effective collection area, which is assumed to be given as a function
3261 of Theta and the true energy
3262
3263 - Added calculation of the migration matrix in the energy
3264 (MHMcEnergyMigration):
3265 the migration matrix describes the migration from the true (E_true)
3266 to the estimated energy (E_est); it is needed to determine the
3267 distribution of E_true from the measured distribution of E_est
3268 by unfolding
3269
3270 - changed the color palette in the camera display to DeapSea.
3271
3272
3273
3274 *** Version 0.6 (2002/01/15)
3275
3276 - Introduce the option of disable pixels (MBlindPixels and
3277 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3278 able to deal with Star Field NSB.
3279
3280 - Fixed a bug in the pedestals substraction
3281
3282 - Introduced verbosity levels
3283
3284 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3285
3286 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3287 work correctly (thanks to Abelardo)
3288
3289 - Introduced correct treatment of the diffuse Night Sky Background
3290 and NSB (MMcPedestalNSB)
3291
3292 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3293
3294 - Introduced MMcRunHeaders which contains monte carlo run informations
3295
3296 - Added a 'Print'-Task (MPrint) which calls the Print function
3297 of a parameter container for each event
3298
3299 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3300
3301 - changes to be more efficient with root 3.02/06
3302
3303 - root 3.02/06 fixes:
3304 + the memory leak when reading MRawEvtData
3305 + loosing more time than necessary to update the progress bar
3306
3307 - MWriteAsciiFile is now capable of writing more than one container
3308 in a line. For example: To be able to write Monte Carlo and
3309 Hillas values (energy and alpha) in one line.
3310
3311
3312
3313 *** Version 0.5 (2001/11/06)
3314
3315 - Added new GUI functionality (Analysis)
3316
3317 - Added a camera display to be able to display events in the camera
3318 together with the calculated hillas ellipse
3319
3320 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3321 object at any state of the analysis, so that the output are several
3322 states
3323
3324 - Fixed a bug in the collection area error calculation
3325 (Thanks to Ciro and Abelardo)
3326
3327 - Fixed a bug which causes merpp to crash in some environments
3328
3329 - Implemented auto enabling scheme for Branches to speed up reading
3330 a lot (see MReadTree and MTask)
3331
3332 - Fixed a bug in the Histogram classes which caused histograms to
3333 be written to a file by MWriteRootFile without request
3334
3335 - changed the object I/O from the old stylish root I/O to the new
3336 'auto evolution scheme' This was done only for classes which are not
3337 yet used in Monte Carlo files, so that these files are still readable.
3338
3339 - Added support for a progress bar in MEvtLoop and MReadTree
3340 (see the Analysis Window in Mars for an example)
3341
3342 - Fixed a bug in the package creation which disturbed the conversion
3343 between a mars version unpacked from a tar file and the repository.
3344
3345 - Changed the code to writer merpped (converted into root format)
3346 raw files, to get faster (around 10%)
3347
3348
3349
3350 *** Version 0.4 (2001/09/20)
3351
3352 - This release is made to compile on a root version >= 3.00
3353
3354 - Fixed a bug which causes MReadTree to read the first file only
3355
3356 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3357
3358 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3359
3360 - Added a task to write several container to a root file (MWriteRootFile)
3361
3362 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3363
3364 - Added calculation of the collection area (MMcCollectionAreaCalc)
3365
3366 - fixed some bugs in the Hillas calculation
3367
3368 - added filters to be able to control the task execution dependent on
3369 a parameter (for example: the number of level 1 triggers in a MC-file)
3370
3371
3372
3373 *** Version 0.3 (2001/04/23)
3374
3375 - Many demo macros added
3376
3377 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3378
3379 - Hillas Calculation added
3380
3381 - Standard image cleaning available
3382
3383 - MReadTree is now able to handle more than one file
3384 (Remark: of the same structure)
3385
3386 - Now we are able to display events in a first version of the
3387 Camera event display. To do this we must run the macro
3388 "macros/readCT1.C" to read data from CT1.
3389
3390
3391
3392 *** Version 0.2 (2001/01/24)
3393
3394 - First Implementation of a Gui to read the raw data. Start the
3395 gui with the command mars.
3396
3397
3398
3399 *** Version 0.1 (2000/12/20)
3400
3401 - First official release 0.1
3402
3403 - Changes:
3404
3405 + changed calling style of MRawPixelIterator from do...while to
3406 while-loop
Note: See TracBrowser for help on using the repository browser.