source: trunk/MagicSoft/Mars/NEWS@ 9614

Last change on this file since 9614 was 9595, checked in by tbretz, 14 years ago
*** empty log message ***
File size: 138.2 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * On some systems (version of make?) the __LINUX__ definition was not set
8 when compiling. This lead to MTime(-1) not working properly. Fixed.
9
10 * The status display is now able to write a plain root file which means
11 that the MStatusArray container is omitted and the TCanvas are written
12 to the file directly. This allows to write files which are accessible
13 from a plain root (without MARS) if no MARS objects are contained
14 in the TCanvas'. In turn the reading of files which contains
15 objects and TCanvas' but no MStatusArray object has been improved.
16
17 * MMcEvt.fPhi and MMcEvt.fTheta have been moved to its base class
18 MMcEvtBasic. Consequently, the direction of the primary shower
19 is not lost in the OriginalMC tree anymore
20
21 ;ceres:
22
23 * Allow for individual mirrors with parabolic shape (for details see
24 MReflector::ReadFile)
25
26 * As an additional output artificial star-files are written. They
27 contain star output compatible output based on the signal as
28 in the artificial callisto output files.
29
30 * The trigger channel which issued the trigger is now stored in
31 MRawEvtHeader::fNumTriggerLvl1
32
33 * The number of photons in the calibration signal is now distributed
34 by a possonian instead of a Gauss.
35
36 * implemented new file-naming scheme (corsika run-number is new
37 tranfered to the ceres output as file-number). Therefore a new option
38 has been implemented to set an artificial run-number:
39 ---run-number=12345
40
41
42
43== Version 2.4 (2009/12/23) ==
44
45 ;general:
46
47 * Added a new palette "temp" to MH::SetPalette which should resample
48 a temperature
49
50 * Added consistency check for two consecutive runs
51
52 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
53 has been disconnected and the L1 (L1TPU) has directly been connected
54 to another bit in the trigger pattern. This has been fixed by an
55 update of the decoding. Both bits are now or'ed together.
56
57 * Added a new camera layout MGeomCamFact which is the "four rectangular
58 pixels ordered in a hexagonal geometry" layout
59
60 * All programs now store the command line as TNamed "CommandLine"
61
62 * the environment variable OSTYPE should now be obsolete. Instead
63 the output of "uname -s" converted to lower cases is used
64
65 * The Makefiles should now detect the OSTYPE automatically using
66 uname. This should make the setting of OSTYPE obsolete
67
68 ;showplot:
69
70 * If a file without a MStatusArray is opened all object (not just
71 canvases) found in the file are drawn. Note that this may result
72 in empty tabs.
73
74 ;ceres:
75
76 * The night sky noise is now scaled with the sensitive area and
77 is given in units per square centimeter
78
79 * The night-sky noise now also takes the cones transmission
80 into account
81
82 * The night sky noise can now be calculated from a night-sky
83 spctrum
84
85 * A transmission curve for the cones can now be given
86
87 * Added the possibility to add a cut after the image parameter
88 calculation (''Cut'')
89
90 * updated the PDE of the GAPDs with a more reliable curve from
91 the meeting page (linear extrapolate below 350nm)
92
93 * The impact distribution in the event distrbutions is now
94 perpendicular to Alt/Az and the histogram is displayed in 1D
95
96 * The GAPD PDE has been updated
97
98 * PDEs and mirror reflectivities have been linearily extrapolated
99 to match the wavelegth range between 290nm and 900nm
100
101 * There is no default pulse shape anymoe it must be given in
102 the resource file
103
104 * Fixed a bug which caused the aerosol coefficient to be incorrectly
105 initialized. The effect might be random but seems to be small.
106
107 * Now accepts sequence files as input
108
109 * creation of pedestal and calibration files is now steered by
110 --mode (see ceres help)
111
112 * Instead of initializing the whole G-APD chip (all cells) before
113 each event (which is rather time consuming) a time evolution before
114 each event is now simulated which is enough to recovere every cell
115 to 99.999% of its response taking the background rate into account.
116 This is in total about a factor of ten faster and should not be
117 less accurate because under normal conditions the recovering cells
118 and the newly hitten cells will hardly be identical (due to
119 statistical reasons)
120
121 * improved the trigger algorithm which is now faster and allows easily
122 for multiplicity triggers
123
124 * The PDC flag in the file name is now correctly written
125
126 * A "PreCut" has been added which can be used after reading the events
127 to select them even before any calculation is done.
128
129 ;merpp:
130
131 * The new drive reports which contain also the status of the starguider
132 are now implemented, but the starting date (17/05/09) is preliminary.
133
134 ;callisto:
135
136 * Fixed a bug which prevented MAGIC Monte Carlo file from being
137 calibrated (ceres files worked)
138
139 * updated (Muon) calibration constants of period 62, 63, 72-75
140
141 ;star:
142
143 * allow to run thru even if discriminator threshold are missing
144 (they are not used for analysis so far anyway)
145
146 ;ganymed:
147
148 * added new starguider calibration for sequences since 1000534
149
150 ;database:
151
152 * added possiblity to query/plot data from certain source (with
153 regular expressions) in plotdb.php
154
155 * new feature in showplots*.php: on mouse-over additional information
156 on the sequence is displayed
157
158 * tables on database website have also 'Last' link now
159
160 * new version of builddatasets.php with more comfortable sequence
161 selection
162
163 * new features in builddatasets.php:
164 - user management
165 - 'Get Data Set File' button
166 - 'Display Selected Sequences' button
167 - 'Display Not Selected Sequences' button
168 - 'Select all' buttons
169
170 * builddatasets.php: added possibility to update data sets in the
171 database
172
173 * added limit for cloudiness for sequences in the tab 'Limits'
174
175 ;automation:
176
177 * jobmanager can be used more flexible now: via environnent variable
178 $AUTOMATIONSETUP more than one jobmanager per user can be started
179 using the same MARS version
180 Usage: export AUTOMATIONSETUP=mysetup ; /fullpath/jobmanager
181 and provide a file Mars/datacenter/scripts/setup.mysetup
182
183
184
185== Version 2.3 (2009/03/07) ==
186
187 ;SUGGESTION
188
189 * There is no need to re-run any data because no change took place which
190 could have an effect on the output. However, if you want a
191 meaningful SrcPos plot for your MCs in sponde you must re-process
192 star for your MCs first.
193
194 ;REMARK
195
196 * File produced with this release containing a camera geometry (which
197 are basically all files were produced as default) will not be readable
198 by older releases.
199
200 ;general
201
202 * fixed a few small bugs which could cause the display to crash in ganymed
203 and sponde
204
205 * in sequence file the date can now be omittet. In this case the
206 leading date with the underscore is missing in the expected filename
207
208 * the geometry class now also supports other geometries than just hexagons
209
210 ;automation
211
212 * added magnetic field Azimuth direction (ARRANG), currently
213 at ~ -7deg at La Palma
214
215 ;database
216
217 * plotdb.php: added default (sequences) for startup, added possibility
218 to set size of plot
219
220 * added a new table ''RunDataCheck'' which containes the rates after
221 image cleaning for every run which succeeded star. It can be
222 plotted using ''plotrundb.C''
223
224 ;merpp
225
226 * added support for Arehucas Version >= 200812140
227
228 * added support for Arehucas Version >= 200809030
229
230 ;mars
231
232 * The display now also displays the trigger pattern
233
234 * The display can now display ceres reflector (_R_) files
235
236 ;ceres
237
238 * added a uniformly distributed one-bin time jitter for the start of the
239 digitization. Otherwise the first photon would be digitized always with
240 the same alignment to the bins
241
242 * Added a plot showing the production height of the photons
243
244 * Moved the particle id from the event header to the run header
245
246 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
247
248 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
249
250 * Added many new options to control the tasks. For deatils see ''ceres.rc''
251
252 * Removed obsolete plots in pedestal and calibration mode
253
254 * Removed the non-NightSky photons from the plots where they are just
255 disturbing
256
257 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
258
259 * The daq event number now represents the readout number
260
261 * The camera ''electronics'' can now be ''switched off''
262
263 * A new tab ''Info'' now display basic things like the reflector
264 layout
265
266 * Improved reading speed for corsika files
267
268 * Improved memory handling (if a large ampount of memory was needed
269 for a single event all further events were stored in the same
270 memory and it was never freed, so the program took this memory
271 until the end)
272
273 * Converted the code from MMCS' reflector program to MSimAtmosphere
274 (instead of the tables build in for MAGIC Winter and Summer
275 atmosphere we use the values written by Corsika fitted to the
276 tabulated atmosphere given as input)
277
278 * For caluclating the displayed image parameters in ceres a basic
279 image cleaning removing isolated pixels is now done.
280
281 * The magnetic field direction (ARRANG) is now taken into account
282
283 * Added plot for the energy threshold after trigger ''Threshold''
284
285 * Added plot for the effective collection area after trigger ''TrigArea''
286
287 ;star
288
289 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
290
291 * The definition of fConcCore has slightly changed. The numbers
292 might decrease a little bit (the effect should be rather small)
293
294 ;ganymed
295
296 * added pointing model 328198
297
298 ;sponde
299
300 * The SrcPos plot for your MCs was so far meaningless because it just
301 displayes the MSrcPosCam data from the input star-files. Unfortunately,
302 this containes was never written to the star-files yet.
303
304 * A new Tab 'OnTime' is available which is an effective on-time
305 fit as in star but for all data. This is mainly for manual cross-check
306 of the effective on-time
307
308 * In some circumstances it might be necessary to re-calculate the
309 eff. on-time from the fit in the new tab, e.g. when a zenith distance
310 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
311
312 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
313 it to its own output file (for convinience)
314
315
316
317== Version 2.2 (2009/01/30) ==
318
319 ;SUGGESTION
320
321 * This release doesn't contain a major change which is expected to
322 change your results. Nevertheless there are small changes to
323 the calibration which can effect at least the first few hundred
324 events in any (mainly MUX and even more SUM) sequence a little bit.
325 So it is recommended although not necessary to reset your sequences
326 in the database before further processing.
327
328 ;NEW
329
330 * A first implementation of a Monte Carlo simulation program
331 (ceres - Camera Electronics and REflector Simulation) has been
332 implemented. It can simulate a full telescope already including
333 a complete reflector simulation and a flexible trigger and readout
334 simulation. Currently, no perfect setup is implemented and
335 especially the output of the program (data structure) should
336 be considered alpha state. Also the user interface is not yet
337 ready.
338
339 ;general
340
341 * All command line options after -- are now interpreted as
342 arguments (usually everything which doesn't start with a minus)
343 rather than options (usually everything which starts with a
344 minus). This allows to use file names starting with a -
345
346 * In all resource files you can now initialize the random number
347 generator. For details see: MJob::InitRandomNumberGenerator
348
349 * added a new program called ''readcorsika''. It's purpose is (in analogy
350 to readraw and readdaq) to read a Corsika output file (for now
351 only cherenkov output is supported) and print its contents in a
352 human readable form. It can also write the contents of this file
353 into a root-file.
354
355 * The calculation of the maximum distance to the origin in a MGeomCam
356 has been improved (edges might be further away than the sides).
357 This is just a tiny change but it might change the appearance of
358 the radial profiles a little bit.
359
360 * The default binning of the center-of-gravity plot has slightly been
361 increased
362
363 ;Database
364
365 * Added informations about the DC currents (fMinCurrents, fMedCurrents
366 and fMaxCurrents). The values are retrieved from the plots showing
367 the average DC currents of all pixels versus time.
368
369 * Websites with tables have now the opportunity to remove lines
370 ('-' button at beginning of each line) and get all lines back
371 ('+' at top of the column)
372
373 * Websites: added option to query only sequences containing sumtrigger
374 events
375
376 * Websites: added option to group by date (year, month, night) for runs
377 and sequences and enabled that combining of different group-bys,
378 e.g. status, date and source is possible
379
380 ;automatic analyis
381
382 * Rewritten producing plots in the web.
383 New plots, namely the output of plotoptical.C (extinction curve from
384 KVA), plotstat.C (status of the automatic analysis (percentage of
385 processed, analysed data etc.)) and plotusage.C (statistics of the
386 condor usage in the data center) has been are available now next to the
387 plots of plotdb.C
388 Mean values from the plots (output of the macro) are provided in a
389 txt file now.
390 The creation of the plots for callisto, star and ganymed in the web is
391 now steered via database. Consequently the plots are faster and
392 reliable up-to-date.
393 For all plots, a new layout is available facilitating the browsing
394 through the plots and providing additional information on the
395 displayed values. (tabs.php) These plots are linked from the DB
396 websites and the wiki.
397
398 ;statusdisplay
399
400 * The ''Loop'' entry in the menu bar now contains an option to pause
401 the loop and to process single events.
402
403 ;merpp
404
405 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
406 instead of RunHeaders)
407
408 * Now allows to merpp files newer than 2008/09/03.
409
410 * Added fixes for wrong (wrong or double) run- and file-numbers
411 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
412
413 ;callisto
414
415 * Extracting the pulse position for the pulse position check events
416 with sum trigger were denied. This decreased the statistics
417 extremely and therefor the resulting puse position was calculated
418 quite weak. Now sum events pass the calculation if and only if they
419 have also a level 1 trigger.
420
421 * the extraction of pedestal events and pulse position from the
422 first data events is now more automatic and makes sure that
423 a more precise number of events is extracted independent of
424 the ratio with which pedestal events or events with signals
425 are contained in the data.
426
427 * Updated Muon calibration constants for all MUX data (teh changes were
428 all smaller than 5%)
429
430 ;star
431
432 * For the calculation of the effective on time all sum-triggered events
433 were skipped. Now all Level1-triggeres events will pass. This might
434 result in a slight inaccuracy of the effective on time.
435
436 ;ganymed
437
438 * If the source position is more than 1deg away from the camera
439 center an error is raised now.
440
441 * Hopefully fixed the bug ''ganymed crashes when resized''
442
443 ;sponde
444
445 * Fixed a problem which causes the fitted spectral slope to be displayed
446 incorrectly. If you use MJSpectrum::FormFlux in your macros make
447 sure that the parameter 0 of your fit is negative.
448
449 * Added a histogram showing the read source position of your MCs
450
451
452
453== Version 2.1.1 (2008/08/04) ==
454
455 ;Database
456
457 * Added the median number of photo electrons from the calibration
458 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
459 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
460
461 * Added fTotOnTime, which is the on-time as given by the run-headers
462 (in contradiction to fAbsOnTime which comes from CC)
463
464 * Added new primaries for the new data structure (Magic II): for the
465 tables dealing with sequences (SequenceBuild Status, Sequences,
466 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
467 this is the telescope number (fTelescopeNumber) for the tables dealing
468 with runs (RunData and RunProcessStatus) this is in addition the file
469 number (fFileNumber)
470
471 * Added column fPriority to the status tables to be able to steer the order
472 in which the data is processed. As default the run, sequence and dataset
473 number are used.
474
475 ;automatic analyis
476
477 * Adapted scripts to the new data structure: They can handle now different
478 telescopes (getting the information as usual from the database).
479 The paths for Magic 2 are not yet implemented.
480
481 ;general
482
483 * should work now with root 5.20/00 (please note that root 5.20/00
484 we encounter crahses in the status display which are ot yet
485 understood)
486
487 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
488 instead of the base name of the file. This makes them easier to
489 access from the code
490
491 * Default Monte Carlo names in MSequence do not require the _E at
492 the end anymore
493
494 * where abrrevating a sequence file with a sequence number is possible
495 also "telescope:sequence" is now accepted, e.g.:
496 star 2:2000123 --out=output
497 see the programs' help for more details.
498
499 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
500 from the database. See the constructors for more details.
501
502 * MReadTree now supports friends
503
504 * MReadTree can now read also files not written by MARS and store
505 the data encapsulated in emulated MParContainers
506
507 * added a new starguider calibration valid since 15.1.08
508
509 ;showplot
510
511 * showplot can now read more than one file at once. This is especially
512 inetersting if reading files containing pure canvases
513
514 ;merpp
515
516 * we merpp the dc currents now also from the camera reports (they have
517 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
518
519 * In the automatic analysis we omit merpping of the currents from the
520 caco files and use the lower rate camera reports from the cc files
521 instead
522
523 * merpp has been redisigned to allow merpping of the cc-reports
524 of a whole sequence. This allows to design a very simple analysis:
525 mkdir output
526 ./callisto 100776 --out=output
527 ./merpp 100776 output
528 ./star 100776 --ind=output --out=output
529 Instead of the sequence number also sequence files are accepted.
530
531 * Implemented a fix for run-numbers between 1001348 and 1001396
532 which were incorrectly assigned by the cc.
533
534
535 ;callisto
536
537 * added a filter again which was was removed in the last release.
538 it removed the most brightest events. This should not change
539 any analysis result because these events are so bright that
540 they cannot be analysed anyway, but the bad-pixel plots doesn't
541 show outliers.
542
543 * updated muon calibration constants for the periods 51-57,
544 58-63 and 67-
545
546 ;star
547
548 * The camera currents are now displayed with the rate of the camera
549 reports instead of the caco reports
550
551 ;ganymed
552
553 * if mc camera files are new enough (>=8) the source position in the
554 camera is now calculated from the stored telscope and shower
555 orientation (Note, that this might not be suitable in all cases
556 depending on the aim of the study. These case still needs
557 implementation)
558
559
560
561== Version 2.1 (2008/06/18) ==
562
563 ;Database
564
565 * introduced average temperature and wind speed from star-files
566
567 * introduced average values from Pyrometer (mainly Cloudiness)
568
569 * introduced the ratio of accepted calibration events in the
570 calibration run
571
572 * introduced the average rates of the different trigger pattern,
573 e.g. the rate of pedestal and calibration events, from the signal-file
574
575 ;general
576
577 * fixed GroupBy options in plot*.C macros
578
579 * only display KVA points (not the Tuorla points) in plotoptical.C
580
581 * all programs now allow to add resources to the ones from the resource
582 file or overwrite them from the command line. This can be done like this
583 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
584 if something seems to be wrong you can debug what the program is doing
585 using the option --debug-env=3
586
587 * increased the diversity of debug levels. That also means that with -v3
588 you get now less output, i.e. only the output which is important for
589 an analysis. To get more output which helps for debugging try 4, 5 and 6.
590
591 * fixed a problem in the task synchronizing the reading of the reports
592 and the data stream. The effect was that in some circumstances the last
593 events of some trees could have been skipped. Since this is only a
594 very tiny part of the data no severe effect to your analysis results
595 is expected (an exception might be very short, i.e. singel runs,
596 datasets).
597
598 * Dataset file now allow to include the sequence file directly within
599 the dataset file and also allow to exclude single runs from the dataset.
600 (for more details see Class reference of MDataSet)
601
602 * Sequence files now allow for excluding runs from the analysis
603 (for more details see Class reference of MSequence)
604
605 * added code to process the sum-trigger flag
606
607 * the histogram classes MH3 and MHn now support profile histograms
608
609 * the histogram classes MH3 and MHn now support labels at the axis
610
611 * the Random Forest Train-classes (MJTRain*) now store the used datasets
612 in the output file
613
614 * the MFMagicCuts have a new option to allow a linear area cut (for
615 special studies)
616
617 * The liniking of the shared object is now done into a file defined
618 by 'mktemp'. This should be a local file system which accelerates
619 liniking a lot.
620
621 * The code has been prepared for compilation with root 5.18/00d
622
623 * The MHEnergyEst histogram now shows the distribution of
624 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
625 and (Eest-Emc)/Emc vs Emc.
626
627 * fixed mars (event display) for merpped raw-data and MC data
628
629 * adapted the synatx of sequence files to allow for the new run/file
630 scheme. For more details see class description of MSequence
631
632 ;showplot
633
634 * Added support for tiff files
635
636 * Added support for csv files (tables containing tab number,
637 name and title)
638
639 * Tabs now can have a title which is displayed in the postscript file
640
641 * When multiple file are written at once (e.g. pngs from a display)
642 it is now possible to use the tab name and or tab number in the
643 file name. For details see showplos's help.
644
645 ;merpp
646
647 * Implemented cc file version 2008-02-20/0
648
649 * Implemented cc file version 2008-05-19/0
650
651 * With new options merpping can be restricted (in addition to the
652 run-number) also by telescope and file number.
653 For details see "merpp --help"
654
655 * Implemented raw data format 11 (the most important change, except
656 from plenty of changes in the format definition, is the addition
657 of the file-number in the header) If nobody makes a mistake this
658 format should have the advantage that it is by definition forward
659 compatible, so old programs will be able to read newer formats.
660
661 * Added Pyrometer information to default output (stored in a new Tree
662 Pyrometer, needs a complete new merpp, i.e. new calibration)
663
664 * Merpping (also update) can now be restricted to one single report.
665 For example:
666 If you want to update an old file with Pyrometer information call
667 merpp --only=Pyrometer --update
668
669 ;callisto
670
671 * in the pedestal processing now at least 50 processed events are
672 required for succeeding.
673
674 * the signal and calib files now contain also the sequence information
675
676 * the two MPedestalCam in the calib file now have proper names
677 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
678
679 * Both pedestal cams now contain the number of events processed
680
681 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
682 i.e. for the extraction of the calibration pulses basically the average
683 over all events of the first slice instead of all slices was used.
684 Since pedestal and calibration constants are continously recalculated
685 this only effected the very first events of every sequence.
686
687 * For the extraction of the position of the maximum sample now the
688 extraction range is set automatically to the extraction window,
689 before the whole accessible range was used.
690
691 * If the number of samples in the events and the number of samples
692 in the run-header disagrees now an error is raised (this can
693 happen in not well simulated Monte Carlo files)
694
695 * In the case of MUX-data pedestal events with the lvl1 trigger flag
696 could survive into the pedestal calculation -- fixed.
697
698 * Tab "TrigPat" added showing the distribution of the trigger pattern
699 as found in the run-files (normalized with the run length)
700
701 * The selection of events from the trigger pattern has been improved.
702 If the trigger pattern is corrupted events won't pass anymore.
703
704 * Added a new command line option --dev-null to suppress output of
705 Y-files (this is useful for test cases)
706
707 * added a new tab "CalPos" showing the arrival time of extracted
708 interleaved calibration events
709
710 * Using the new --test switch you can now calibrate the calibration
711 file
712
713 ;star
714
715 * the star file now contains also the sequence information
716
717 * Added a new command line option --dev-null to suppress output of
718 I-files (this is useful for test cases)
719
720 * Tab "Rate" added showing the distribution of the trigger pattern
721 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
722 the Y-files (normalized with the run length)
723
724 * The effective on-time calculation doesn't use events with only
725 sum-trigger anymore
726
727 * The data in the MHWeather tab has been reorganized. The never
728 working solar radiation has been removed and the data from
729 the pyrometer (cloudiness, air and sky temperature) is
730 displayed in addition.
731
732 ;ganymed/sponde
733
734 * Now data points are even shown correctly if they have error bars larger
735 than one sigma. Points with null or negative significances are omitted.
736
737 * DrawNicePlot now allows to set a projection range
738
739 * Updates pointing models. One is applied after the implementation
740 of the new LUTS in August, the other one is applied after the
741 next major change of the pointing model in October. Note that
742 these models are preliminary and give wrong results below Zd=65deg
743
744 ;sponde
745
746 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
747
748 * a new option "--force-runtime" is available. In case of very short
749 datasets (for light-curves) which are in the order of a few
750 minutes the calculated effective on-time is not very acurate because
751 it is quantizised in the order of a minute. Therefore you can switch
752 to using the real run-time instead (remakrt: this ignores any
753 dead-time!)
754
755 * a more analytical way is used to "fill" Monte Carlos into regions
756 of impact parameters which have not been simulated because the
757 trigger efficiency is assumed to be 0.
758
759 * estimated sensitivity curves for hi and lo zenith angles are shown
760 scaled to the correct observation time and collection area
761
762 * the Monte Carlo events after cuts are now written to the output file
763 if an output file given
764
765
766
767 *** Version 2.0 (2007/09/03)
768
769 - database: the position used for the pulse pos check was missing
770 in the callisto output and could thus not be filled into the DB.
771 Also the old values seemed not exactly the PulsePos used for
772 teh check.
773
774 - general: Resource file now allow an Include-Resource, i.e. you can
775 read a resource file with default settings, include it in your
776 resource file and overwrite the settings in your file. More than
777 one include file is allowed. Inclusions can be iterative.
778 Include: mydefaults.rc yourdefaults.rc
779 The resources in the first file have higher priority than the
780 second file.
781
782 - general: Now the output files (calib*.root, etc) also contain the
783 resource file (to check it open it in the TBrowser and choose Print()
784 from the context menu)
785
786 - general: Dataset files now allow to overwrite the default path
787 to search for sequence and data files. Note, that the program
788 option and individual resources will overwrite it. For example:
789 SequencePath: /magic/montecarlo/sequences
790 DataPath: /magic/montecarlo/star
791
792 - general: Fixed a problem with variables in MDataPhrase. It seems
793 that only optimdisp (didn't work) was effected.
794
795 - general: Some improvements to the optim and train processing. For
796 example the ststud window now got a proper title.
797
798 - general: The "Status Display: " was removed from the window title
799 within an Eventloop.
800
801 - general: added a new flexible histogram-class (MHn) which can be used
802 for example in testing after optimizations or training to produce
803 user defined histograms.
804
805 - general: The Random Forest now allows attaching an evaluation
806 function which is applied to its output. This allows to train
807 on whatever you like (eg. train on log10(energy), but return
808 energy)
809
810 - general: The Random Forest training of energy (trainenergy.c) and
811 disp (traindisp.C) has been improved by more graphical output to
812 judge the result.
813
814 - general: The training of energy (trainenergy.C) has been improved
815 a lot by training on a different quantity than energy. It gives
816 a result which is highly independant of the source spectrum
817 and shows lower bias than all other options.
818
819 - general: Dataset files are allowed to contain collections of
820 datasets. For more details see the class reference of MDataSet.
821
822 - general: The default WobbleMode in a datset file now (if not
823 overwritten) is "auto", i.e. wobble mode is set if the dataset
824 doesn't contain off-sequences.
825
826 - merpp: Merpp can read file format version 9 now. Please realize
827 that for file format version 9 the extraction range is different
828 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
829 the first and last 15 slices have been removed from all MUX data.
830
831 - mars: Similar to writing movies you can now select events which
832 should be displayed in your display. Therefore add the following
833 lines to your mars.rc:
834 MFEvtNumber.FileName: ganymed00223552.root
835 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
836 The input file can be a ganymed-file after (ganymed*.root) or
837 before (ganymed*-summary.root) file. For example to select all events
838 from your on sample after cuts (excluding the ThetaSq cut) use
839 MFEvtNumber.Selector: DataType.fVal>0.5
840 To show all events from your on-sample after quality cuts
841 use the summary file instead.
842
843 - mars: new ways to call mars are implemented. Instead
844 of calling
845 mars filename.root
846 you can now also use
847 mars sequence.txt
848 or
849 mars sequence.txt inputpath
850 or replace sequence.txt by the sequence number if the default
851 sequence file should be used.
852
853 - mars: The default size has been increased
854
855 - mars: There are two new heckboxes which allow to switch off
856 the calculated image parameters
857
858 - callisto: was broken for MCs... fixed.
859
860 - callisto: improved calculation of spline coefficients a lot. This
861 leads to a further improvement of the event rate calibrating MUX
862 data of about 15% (175evt/s instead of 150evt/s)
863
864 - callisto: finally the raw data we read is now real 16bit (with
865 10bit precision) for MUX data and not a stripped 8bit number
866 anymore. Due to scaling of the numbers (without precision loss
867 into an [0-256[ range, the final numbers for pedestal, pedestalrms
868 and extacted signal don't change. However, at all places where
869 raw data is directly accessed (eg. saturation and variation
870 limits in the signal- and pedestal-extraction) the numbers
871 refer still to the data's 16bit range.
872
873 - callisto: The maximum arrival time difference used in the bad
874 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
875 for both, old FADC and MUX-FADC, data.
876
877 - callisto: Be aware that callisto is now calibrating the arrival time
878 in nanoseconds rather than time slices. Also all following tasks
879 have been changed to assume ns units now. If you star data
880 calibrated with an older version it might be necessary to adapt
881 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
882 to obtain optimal results. The plot in the PulsePos tab
883 will now be in ns, too. This might also mean that the Muon
884 analysis in star might not work as perfect as expected as long
885 as old files read in.
886
887 - callisto: The calibration constants of earlier updates got lost
888 somehow. All constants have been updated.
889
890 - star: The PSF is now determined from the profile of the ArcWidth
891 instead of arcwidth/radius. The old way gave to much weight
892 to the bins with low statistics. The reference lines have been
893 updated.
894
895 - star: For speed reasons events suitable for the muon analysis
896 are now also preselected by fConcCOG<0.1 which seems to be a very
897 good preselector for muons.
898
899 - star: is now calculating a new timing parameter the Slope along
900 the major and minor axis of the shower. Therefore a numerical
901 solution of a line-fit is used. To use MHillasExt.fSlopeLong
902 and MHillasExt.fSlopeTrans don't forget to multiply it with
903 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
904
905 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
906 have been removed from MNewImagePar. They have never been good for
907 anything.
908
909 - star: Implemented a new recursive algorithm which is supposed to be
910 faster. Also implemented new cleaning oiptions, which are:
911 + CleanLevel0:
912 The cleaning level above single core pixels can be kept
913 + KeepIsolatedPixels:
914 Define whether single core pixels should be kept
915 + TimeLevel1:
916 The coincidence window in nanoseconds to single used neighbors
917 + TimeLevel2:
918 The coincidence window in nanoseconds to two used neighbors
919 + PostCleanType:
920 MOde in which a time dependent post cleaning should be applied
921 0: No post cleaning
922 1: Require for each used pixels at least one used neighbor
923 within a time-window of CleanLevel1
924 2: Require for each used pixels at least two used neighbor
925 within a time-window of CleanLevel2
926 3: Require first two and second one used neighbor
927 within a time-window of CleanLevel1 and fCleanLevel2
928 respectively
929 + RecoverIsolatedPixels:
930 - recoveres isolated core pixels if they have a used neighbor
931
932 - mars/star: The new default cleaning is:
933 + CleanLevel1: 6.0
934 + CleanLevel2: 3.0
935 + CleanTime1: 1.75
936 + CleanTime2: 1.75
937 + PostCleanType: 3
938
939 - star/ganymed: The old spark-cuts have been replaced by new ones.
940 These new spark cuts have been cross checked with the sequences
941 84720 (before splitter), 101041 (after splitter) and 223539 (new
942 FADCs). In all cases they seperate pretty well, but of course not
943 perfect. Monte Carlos have suggested to tighten the cuts a little
944 bit further at low sizes. This has been done.
945
946 - ganymed: IMPORTANT - The spark cuts have been changed to match
947 all available data more or less well. This might mean that for
948 YOUR data there are still sparks visible.
949 Whenever you do an analysis you have to make sure that NO sparks
950 survive your cuts!
951
952 - ganymed: The old hadronness and size cuts have gotten new indices
953 (10, 11). The old indices 8 and 9 now mean an additional condition
954 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
955 If you want to switch off this cut just move the line far away enough,
956 e.g. by setting c[9] to -500. Please update your ganymed.rc files
957 accordingly!
958 The unit of c[9] is deg. It is the dist at which your cut will
959 cross the slope==0. The unit of the slope is ns/deg. So if
960 you readin files calibrated with an older Mars-version you
961 have to adapt the default value for c[9] to the FADCs:
962 - Multiply by two for the MUX FADCs (run number > 200.000)
963 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
964 - Multiply by 42 for the meaning of life (run number = 200.000)
965
966 - ganymed: The old Cut0 is now called CutQ and is calculated before
967 the source position is caluclated. If you need a quality cut
968 including source dependant data (be very carefull with this!)
969 you have to use Cut0 instead.
970
971 - ganymed: now properly supports three off regions in wobble mode.
972 It will be the default from now on in ganymed_wobble.rc. To change
973 the number of off-regions use
974 NumOffSourcePositions: 1
975 in your ganymed.rc. Also by default no off-theta cut will be done
976 anymore so that you will get a background level higher than the
977 signal level in your ThetaSq plot for ThetaSq>0.2.
978 Due to this be carefull changing the scaling mode away from
979 "None". You will underestimate your signal if your scale interval
980 is not properly set.
981 (Rem: ThetaSqN is no longer needed)
982
983 - ganymed: is now storing the events of all (on- and off-)
984 source positions even in the case of more than one off-source
985 position. This should allow sponde to work properly and the
986 energy estimation is done correctly in all cases (without any
987 "nearest position" trick)
988
989 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
990 with a real pointing model for the starguider is done, calibrated
991 with more than thousand tpoints taken from this date on.
992
993 - ganymed: was broken for Wobble-MCs... fixed.
994
995 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
996 has changed. Note that your old ganymed.rc will be incompatible
997 with the new algorithms! Please check the ganymed.rc files and
998 the class description of MFMagicCuts for more information.
999 It is recommended at the moment to use identical Disp-Parametrizations
1000 for on/off- and wobble-mode. If cuts are optimized only
1001 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
1002 should be optimized. All other values should be kept as they are.
1003 If you want to do an anylsis without timing a parameters, you can
1004 switch off the timing cuts by seeting parameter 7 to a very small
1005 value (eg. -99). To remove the slope parameter from the disp
1006 paremtrization set parameter 8 to 0.
1007
1008 - ganymed: The distribution of observation time versus zenith
1009 angle is now shown for off- AND on-data.
1010
1011 - ganymed: The contents of the source position plot are no longer
1012 averaged, thus a lot of (fake) events between the two wobble
1013 positions have disappeared.
1014
1015 - ganymed: There is a new tab "CutT" it contains the VsSize plots
1016 with the CutT, whihc is defined in ganymed.rc, applied. It
1017 is resonable to use your theta-cut for it, to see if there is
1018 something strange (sparks!) in your signal-region.
1019
1020 - ganymed: To choose a dataset from a collection in a dataset file
1021 use the new command line option "--dataset=12345"
1022
1023 - optim, sponde: should now properly support three off-regions.
1024 Just produce your ganymed summary files with three off-regions.
1025 optim and sponde will automatically get all off events from
1026 all off-regions from this file. Please do not forget to
1027 set the scaling in optimwobble.C properly:
1028 fit.SetScaleUser(1./3);
1029 it is not yet read in automatically (will follow soon).
1030 In the case of fixed Scale you can also use
1031 cuts.SetThetaCut(MFMagicCuts::kOn);
1032 no off-cut needed.
1033 Be carefull in case of three off-regions when switching on
1034 scale mode. Make sure that the scale interval is set correctly.
1035
1036 - sponde: sponde.rc and sponde_onoff.rc are now idetical
1037
1038 - sponde: the resouce files have been rewritten with a lot of
1039 comments and a well working parametrization for an energy estimator
1040
1041 - sponde: In the estimated energy versus monte carlo energy plot the
1042 contents where exchanged.... fixed.
1043
1044 - sponde: the so called "accurate"-mode has been removed. It didn't
1045 give any improvement in accuracy, only decreased execution speed.
1046
1047 - sponde: the so called "simple"-mode has been removed. It didn't
1048 give any improvement in simple.
1049
1050 - sponde: the so called "refill"-mode has been removed. It was anyhow
1051 not implemented.
1052
1053 - sponde: now checks whether the theta distribution of your on-data
1054 and the theta-distribution of your Monte Carlo sample (after
1055 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
1056 sample is incomplete) execution is stopped. Execution can be forced
1057 using the new option --force-theta. Use this option with care!
1058
1059 - sponde: Proper collection areas can now be constructed also from
1060 Monte Carlo samples generated with different maximum impact
1061 parameters. Note that in previous version you neither got
1062 a warning or failure, nor was there any obvious sign that the
1063 collection area was overestimated due to usage of files with
1064 different maximum impact parameters.
1065
1066 - sponde: If MC files with different lower energy limits are used
1067 the primary MC spectrum is artificially completed down to the
1068 lowest energy used at all. WARNING: that this gives correct
1069 collection areas ONLY if none of the events in this region would
1070 survive your cuts at all.
1071
1072 - sponde: the output file now contains more information about
1073 the spectrum (eg. the full 2D collection area histogram).
1074 Note, that this information can only be written to the file
1075 if it is stored automatically via command line argument.
1076 If you only store the status display from within the display
1077 the information is lost.
1078
1079 - sponde: added a new tab "Disp". It shows the residual of the disp
1080 (Disp-Dist) versus several parameters and it is meant to judge the
1081 quality of the disp estimator. In the ideal case the residual is zero
1082 and doesn't depend on any variable. The tab is displayed after
1083 CutQ and Cut0.
1084
1085 - sponde: added a new tab "Energy". It shows the residual of the
1086 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1087 several parameters and it is meant to judge the quality of the
1088 energy estimator. In the ideal case the residual is zero
1089 and doesn't depend on any variable. In reality even a good estimator
1090 can show residuals versus Monte Carlo energy. The tab is displayed
1091 after all cuts.
1092
1093 - sponde: added a new tab "EventDist" showing the unweighted real
1094 absolute number of events of your sample after cuts. This tells
1095 you how many events with this energy you had in your MC files.
1096 The same information you get from the error bars of the weighted
1097 histograms, but this is less intuitive.
1098
1099 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1100 for comparison. It is not meant to show these curves in
1101 publications, they are only for production.
1102
1103 - sponde: The OriginalMC tree with the events produced by corsika
1104 is now processed only once
1105
1106 - sponde: Finally fixed most annoying bug, which has effected the
1107 last bin of the collection area. It was the problem that binnings
1108 of root histograms are from 1 to n (included) but there was a C-like
1109 loop in sponde from 0 to n (excluded). Now the loop also includes
1110 correctly under- and overflow-bins. The worse thing with this is,
1111 that for the events in the highest bin not only the bin-content
1112 was wrong, but also the weights applied to these events, which could
1113 in pricipal effect also other parts of the distribution (eg. due
1114 to energy estimation). Fortunately it effected only a few events
1115 in most cases.
1116
1117
1118
1119 *** Version 1.2 (2007/05/14)
1120
1121 - database: The database now has two new values Unsuitable50 and
1122 Unsuitable01. They express the number of pixels which are
1123 unsuitable for more than 50%, respectively more than 1%, of
1124 all calibrated event. It is a more accurate number than the
1125 previously used numbers, because they only take the first
1126 calibration (ignoring the interleaved calibrations) into account.
1127
1128 - database: The database now has two other new values UnsuitableMax and
1129 DeadMax. They express the maximum number of pixels which were
1130 unsuitable, respectively dead, during the sequence. Because
1131 of high pedestal rms (cars passing) a few events with very high
1132 numbers of unsuitable pixels can happen. Not to suffer from this
1133 effect we don't take the highest 0.1% of the numbers into account.
1134
1135 - general: fixed a bug which caused callisto and star to stop working
1136 properly because the callisto output was currupted
1137
1138 - general: a script called scripts/makemovie has been added which
1139 simplified the process of producing several movies from a single
1140 sequence with different setup.
1141
1142 - callisto: Some more code cleanup. Started to remove old obsolete
1143 code from cvs.
1144
1145 - callisto: The extraction of the pedestal with the extractor was
1146 not random. It seems that extracting at one position is still biased
1147 (for example in the first or last slices we could still suffer from
1148 switching noise) Now it is completely random.
1149
1150 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1151 pedestal files) individual pixels could be skipped due to high
1152 variations. This was already the case for the pedestal extraction
1153 from the lo-gains since the beginning and properly handled
1154 there, but was introduced in the extraction from the pedestal files
1155 a while ago. To calculate the average value it was still divided
1156 by the number of events procesed not by the number of summands
1157 really summed. This let to a pedestal which was a tiny amount too
1158 small (for a few piels in the order of 0.1%). This led to an slightly
1159 positive offset of the randomly extracted pedestal for a few pixels.
1160 I doubt that this has a big effect on the result, because the effect
1161 on the individual numbers is quite small. Due to this it is suggested
1162 that you rerun your calibration to make sure you are without any
1163 avoidable bias.
1164
1165 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1166 the median rms of the absolute arrival time and expressed in significance
1167 levels. This replaces the old meaning of an abolute upper limit. An
1168 absolute upper limit doesn't make much sense, because in our data
1169 all arrival times are shifted at the same time (in fact it might be
1170 a shift of the artificial trigger w.r.t. to the light flash).
1171
1172 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1173 of the number of unsuitable pixels over the whole sequence. This
1174 is usefull mainly to judge if an intermediate calibration had
1175 problems.
1176
1177 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1178 of the number of dead pixels over the whole sequence. Dead pixels
1179 in this context are unmapped pixels, i.e. pixels which could not
1180 be interpolated, and thus are ignored in the further analysis.
1181
1182 - callisto: It is now possible to use the position of the maximum
1183 of the spline as arrival time instead of the leading edge even
1184 when using the integral for the signal. Therefor set the extraction
1185 type to kIntegralRel ("IntegralRelative") and the relative height
1186 ("HeightTm") to -1:
1187 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1188 MJPedestalC1.ExtractSignal.HeightTm: -1
1189
1190
1191
1192
1193 *** Version 1.1 (2007/04/27)
1194
1195 - general: The new class MGeomCamDwarf contains the camera geometry
1196 for our prefered Dwarf camera and can be used to create general
1197 geometries of roundish or hexagonal cameras.
1198
1199 - mars: The default cleaning is now abolute 8.5/4.0.
1200
1201 - mars: The resource file mars.rc now contains examples for MUX data
1202
1203 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1204 data containing only 10-bit information is still cooked down to
1205 8-bit, by cutting away the lowest 8-bit.
1206
1207 - merpp: When reading raw data the data is now stored in a single
1208 array. The lo-gain array is obsolete. The interface stays the same.
1209
1210 - callisto: To process the new MUX data use the resource file
1211 callisto_mux.rc
1212
1213 - callisto: The -root and -raw options to read merpped raw data have
1214 been removed
1215
1216 - callisto: If the -mc option is given the sequence-name can now be
1217 replaced by the MC sequence number
1218
1219 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1220 -mc option can now be omitted
1221
1222 - callisto: Started further simplification by removing obsolete
1223 dependancies on MCalibIntensity*Cams.
1224
1225 - callisto: removed unsused intensity calibration from MJCalibration
1226 for further simplification
1227
1228 - callisto: for simplification removed references to
1229 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1230 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1231 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1232 (this should at minimum change nothing at all, and at maximum
1233 improve thing if these containers where somewhere not handled
1234 properly)
1235
1236 - callisto: Added the option to write an event movie. Please use
1237 this option with care (huge files) but exessively to understand
1238 our events. For further documentation please refer to the
1239 IACT wiki
1240 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1241
1242 - callisto: Improved binning for the pulse position check histogram
1243
1244 - callisto: The code calculating the pulse position checknow takes
1245 the pedestal into account
1246
1247 - callisto: The arrival time is now stored with full precision this
1248 helps to get rid of artefacts in histograms. For the signal this
1249 is not necessray because it is displayed in log-scale anyhow
1250
1251 - callisto: Fixed a problem with internal exclusions. Pixels which
1252 have once been marked as unsuitable didn't get the necessary
1253 histograms filled anymore to be rechecked with each interleaved
1254 calibration.
1255
1256 - callisto: The relative arrival time resolution (the rms of the
1257 relative arrival time offset) is now checked against its
1258 median and the median deviation, instead of the average
1259 plus an absolute offset.
1260
1261 - callisto: The relative arrival time offset is now calculated
1262 w.r.t. its median not w.r.t. to an artificial reference pixel.
1263
1264 - callisto: The relative time calibration now marks pixels with
1265 outlaying offset as unsuitable
1266
1267 - callisto: The interleaved relative time calibration has been switched
1268 on. The advantage is that pixels which are marked as outliers
1269 now can recover. An improvement over time is not expected, because
1270 the relative time calibration seems stable.
1271
1272 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1273 option can now be omitted.
1274
1275 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1276 or the option "-mc" is specified as default the monte carlo datacenter
1277 paths (/magic/montecarlo/...) are used if not overwritten in the
1278 dataset file.
1279
1280 - ganymed: The output files now contain run- and event-number for all
1281 events, accessible as RunNumber.fVal and EvtNumber.fVal
1282
1283 - ganymed: Added a plot showing the source position in the camera also
1284 for wobble mode
1285
1286 - ganymed: In addition to the existing task which can be setup to
1287 be executed after Cut1 a final task called "EstimateEnergy"
1288 has been added, executed before writing the final output
1289 (ganymed00000000.root). The task setup in all three cases
1290 can be choosen individually. (For all three(!) cases you
1291 can for example choose MRanForestCalc. For examples see all
1292 sponde*.rc and all ganymed*rc)
1293
1294 - ganymed: If a container "MEstimatedEnergy" is found in the
1295 parameter list (eg. because it was setup by MEstimateEnergy)
1296 it will be written to the output file.
1297
1298
1299
1300 *** Version 1.0 (2007/02/16)
1301
1302 - database: Website to plot values from the database has been added.
1303
1304 - database: The rate of spark events as found by star is now kept
1305 and the rate after cleaning is now with spark events subtracted
1306
1307 - general: The changes to the interpretation of phrases lead to
1308 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1309
1310 - general: Added example files how you can create your own calendar
1311 (eg. as christmas present) with Mars. Just run
1312 root macros/tutorials/calendar.C
1313
1314 - general: Added a possibility to display grouped data in the plotdb.C
1315 macro (and similar macros). This allows to plot hourly, nightly,
1316 weekly, monthly and yearly averages.
1317 For more details see the plotall function of the macro
1318
1319 - general: fixed the error display of the camera display. It showed
1320 wrong results.
1321
1322 - general: fixed a memory leak when reading many MStatusDisplays
1323
1324 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1325 between a spherical and a parabolic mirror
1326
1327 - callisto: We have a new pulse position check which takes the properties
1328 of the extractor automatically into account. So no need to set
1329 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1330 left is done. If possible the lo-gain extraction start and hi-gain
1331 extraction end is changed accordingly. If no proper extraction range
1332 can be set (hi-gain too much to the left) an error is raised.
1333
1334 - callisto: New swapped pixels have been found and corrected
1335
1336 - callisto: Redone the signal extraction this includes:
1337 + Unified the algorithms to extract the pedestal for all pedestal
1338 extractions done
1339 + Unification of hi- and lo-gain into one array
1340 + Unification of hi- and lo-gain extraction for Spline and
1341 Digital Filter (means now exactly the same algorithm is used,
1342 not a copy-and-pasted one)
1343 + Store pedestal subtracted data in a common place
1344 + Improved extraction algorithms. If the algorithms search a
1345 maximum but don't find one they don't return the maximum anymore
1346 + Improved the extraction such that a information for signal
1347 and time which is consistent is returned
1348 + replaced the numerical spline with a (not slower) analytical
1349 solution
1350 + Lowered the saturation limit from 250 to 245 to make sure that
1351 we are far away in all pixels from problems with the clock-noise
1352 + The start of the lo-gain extraction is calculated from the hi-gain
1353 arrival time. In case of saturation an estimation is used.
1354 + the hi-gain window was extended to slice 16. This allows extraction
1355 of very late pulses in single pixels or of huge hadron showers.
1356 + Now uses the lo-gain extraction range for pedestal extraction,
1357 not the hi-gain range in the lo-gain
1358
1359 - callisto: New hi-/lo-gain calibration constants have been produced
1360 for all periods from the statistic of the whole period. They are
1361 now used automatically depending on the periods. The old constants
1362 where deviation in avarega about 2%-3%. The constants are very
1363 stable from period to period (<<1%) except for exchanged channels.
1364 In a few cases the constants used so far were off by 1%-2% (maybe
1365 temperature effects?)
1366
1367 - callisto: To gain obsolete space we do not write the
1368 MPedestalFundamental anymore. Also calibration and bad pixel
1369 treatment is not done for it anymore because it has never been used.
1370
1371 - callisto: Fixed a bug in the seuqence handling which caused the
1372 light condition to be ignored
1373
1374 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1375 basically the same as "Cleaned" but the distribution devided into
1376 the events fullfilling a spark cut or being rejected by it.
1377 This cut can be changed from star.rc (see example inside) by
1378 the "SparkCut" directive
1379
1380 - star: Star displays now the average individual pixel-rate (IPR) versus
1381 time and the average discriminator threshold (DT) of all pixels.
1382
1383 - optim: fixed a problem with the optim-macros which was due to a bug
1384 in the new phrase parsing
1385
1386 - ganymed: To get a nice FalseSource plot (instead of the all-information
1387 debug plot displayed as a standard plot) use the context menu
1388 somewhere between the two upper plots, click on "DrawNicePlot"
1389 and enjoy the result. (It is the same context menu which contains
1390 the other options)
1391 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1392
1393 - ganymed/optim/train: The cut program, trainings- and optimization
1394 macros could run with less files found than expected from the
1395 sequence-files. No the execution is stopped in this case.
1396
1397 - ganymed: now stores the dataset in the output file with all information
1398 contained (as sequence number, sequence path, data path) so that the
1399 used dataset file can be recreated complete from the output
1400
1401 - sponde: now also allows the uasge of random forest
1402
1403 - sponde: added a plot showing the cut efficiency
1404
1405 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1406 errors (eg. effecting the collection area) because the errors of the
1407 two histograms were swapped in the calculation, which makes a difference
1408 in the case the histograms contains weighted events. Aditionally the
1409 totalarea was incorrectly taken into account, which results in too small
1410 errors, which makes a difference at low statistics were the errors
1411 or the collection area dominate.
1412
1413
1414
1415 *** Version 0.10.3 (2006/10/23)
1416
1417 - database: Implemented ObservationMode flag in websites.
1418
1419 - database: For sequences there is now also the stoptime available on the
1420 websites.
1421
1422 - database: Removed ManuallyChanged flag from sequence-info websites,
1423 as it is not needed anymore with the new sequence building algorithm.
1424
1425 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1426 Class for calculation of confidence intervals (upper limits).
1427 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1428 Please read the class instruction of TRolke for more information.
1429
1430 - general: The programs now return 0xfe if the requested resource file
1431 doesn't exist.
1432
1433 - general: Errors comming from root itself are now not output to
1434 stderr anymore but to our default (colored) log-stream.
1435
1436 - general: Changed the interface to TFormula such that now everything
1437 is parsed by TFormula, which should allow to use phrases even
1438 without paranthesis correctly parsed.
1439
1440 - callisto: replaced the AdHoc number of effective integration slices
1441 in the digital filter by an average of the correct number, averaged
1442 over all possible set of weights. This also gives correct numbers
1443 for the lo-gains which were totally wrong before.
1444
1445 - callisto: drastically reduced memory consumption by not storing
1446 all intermediate calibration results in memory anymore (we might
1447 write them into a file in the future)
1448
1449 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1450 debug plot displayed as a standard plot) use the context menu
1451 somewhere between the two upper plots, click on "DrawNicePlot"
1452 and enjoy the result. (It is the same context menu which contains
1453 the "DrawAll" option)
1454 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1455
1456
1457
1458 *** Version 0.10.2 (2006/10/15)
1459
1460 - general: changed the building of the sequence files such, that
1461 the source-/project name in case of wobble-sources is not the
1462 source/project of the first data run anymore but the new generalized
1463 wobble source/project
1464
1465 - general: Added some functions to MAstro to calculate sun and
1466 moon properties
1467
1468 - general: Added two new macros (starvisday.C and starvisyear.C)
1469 which allow to plot the visibility of several stars in one day
1470 or of one star along one year
1471
1472
1473
1474 *** Version 0.10.1 (2006/10/11)
1475
1476 - general: HTML logging output was distorted... fixed.
1477
1478 - general: Changed the writing of the sequencefiles such that only
1479 as many pedestal files as giving at least 1000 pedestal events which
1480 are nearby the first calibration run are used as pedestal runs
1481
1482 - sponde: In the calculation of the collection area(s) and the
1483 distribution for MOnte Carlo and estimated energy the error
1484 calculation was wrong because root didn't take the errors
1485 properly into account... fixed.
1486
1487
1488
1489 *** Version 0.10 (2006/10/10)
1490
1491 - general: all executables now check consistency of the root version
1492 installed with the root version used for compilation. The return
1493 code in this case is 255.
1494
1495 - general: The algorithm to build seqeunces has been redesigned
1496 completly. It is now more flexible in terms of a resource file
1497 resources/sequences.rc which can be used to partly overwrite
1498 the default algorithm and defined the important part of the
1499 algorithm. It also takes correctly into account several ways
1500 of taking wobble-data. Currently the new algorithm doesn't take
1501 the number of pedestal events anymore into account (so a sequence
1502 could have much less than 1000 pedestal events and data runs are
1503 no-more used instead)
1504
1505 - general: a lot of small changes to make the code compatible with
1506 root 5.12/00 and gcc 4.1
1507
1508 - general: Fixed some warnings thrown if more warnings are switched
1509 on in the compiler
1510
1511 - general: Added a function to MMath which returns the Median of
1512 the distribution abs(y[i]-median) but at 68:32 division instead
1513 of 50:50, which is somehow the median counterpart of the rms.
1514
1515 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1516 even if they are compressed with gzip (recommended compression
1517 is with "-1")
1518
1519 - showplot:
1520 + batch mode creation of image files now works with root 5.12/00
1521 + added support for writing bmp (though it never produces
1522 bmp which can be read by programs like xv or gimp)
1523 + added support for xml
1524 + added new option to start the display with a different size, by
1525 --display-width=nnn or --display-height=nnn
1526 + added options to define the canvas size when the display is started
1527 --canvas-width=nnn or --canvas-height=nnn
1528 the option can also be used for batch-mode conversion
1529 + added an option which automatically fits the display size to the
1530 desktop-size: --auto-size
1531
1532 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1533
1534 - merpp: allow the reports to have 1000ms due to a bug in the camera
1535 program.
1536
1537 - callisto: New swapped pixels have been found and corrected. For
1538 details see MRawRunHeader::FixAssignment()
1539
1540 - callisto: Callisto now raises an error if one of the input files could
1541 not be opened.
1542
1543 - callisto: In some rare cases it could happen that in the signal
1544 extraction of the digital filter the extractor returned nonsense
1545 results due a wrong initializion of a variable (this happens in
1546 cases in which the extracted signal is exactly zero or the
1547 digital filter couldn't slide because of a too small extraction
1548 window, which could happen in the lo-gain extraction)
1549
1550 - callisto: The lo-gains have been marked as valid in some cases
1551 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1552 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1553 smaller than the number of slices (fLoGainWindowSize) needed
1554 by the lo-gain extractor
1555
1556 - callisto: Updated absolute calibration constants (muon calibration)
1557
1558 - callisto: fixed a bug which caused the hi-gain saturation not
1559 to be handled properly in the spline (the position of the
1560 saturation was calculated incorrectly)
1561
1562 - callisto: fixed a bug which gave weird results if hi- _and_
1563 lo-gain could not be extracted properly. In some cases hi-
1564 and lo-gain have not been extracted at all and the random result
1565 got calibrated. In other cases the hi-gain was saturating and the
1566 lo-gain has not been extracted. For this a completly arbitraty
1567 scale factor was applied to the result from extracting the
1568 charge of the saturating hi-gain.
1569
1570 - callisto: improves handling of extracted signal if lo- and/or
1571 hi-gain could not be extracted properly. If no appropriate
1572 calibration of either the signal or the arrival time is possible
1573 the pixel is now markes as unsuitable instead of estimated.
1574
1575 - callisto: Fixed a problem in the spline extraction which gave
1576 weird results if the signal was extracted from the first (and
1577 highest) slice (as a workaround extraction from the first
1578 slice has been forbidden)
1579
1580 - callisto: Fixed a bug regarding the use of the QE which doesn't
1581 effect the result because the default is used anyhow.
1582 (The bug was there since 14/07/2005)
1583
1584 - callisto: Changed the default for fgLoGainStartShift to -2.4
1585
1586 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1587 factors to be always 10 for all pixels as soon as the first
1588 calibration update has happend.
1589
1590 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1591 was off by more than one slice (which gives wrong values for
1592 pixels which have saturated the hi-gain) This was a problem
1593 mainly for timing studies, not so much for the automatic standard
1594 analysis. Also the values for the Spline have been changed slightly:
1595 + Digital Filter from 1.70 to 0.95
1596 + Spline from 1.39 to 1.30
1597 The numbers were sorted out by an extensive test in the
1598 test-database.
1599
1600 - callisto: Removed the tab showing the average calibrated arrival
1601 time. It never gave useful information.
1602
1603 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1604 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1605 and both were extracted because the hi-gain was above the
1606 LoGainSwitch.
1607
1608 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1609 lo-gain pulse position (after application of LoGainOffset, which
1610 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1611 have saturated and both were extracted because the hi-gain was above
1612 the LoGainSwitch.
1613
1614 - callisto: After extensive tests a new threshold level for determination
1615 of the pulse position has been found at 50phe. This is due to the
1616 fact that for lower pulses the arrival time changes its average
1617 behaviour dramatically. It tends to the average of the extraction
1618 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1619
1620 - callisto: Added two more plots to the calibration part. The average
1621 extracted signal and the average extracted arrival time as
1622 extracted by the signal extractor (This can help debugging problems
1623 because it doesn't involve a fit)
1624
1625 - star: changed the fit for the effective on time such that initial
1626 values are calculated automatically now instead of using build
1627 in values. This makes the fit more indepedant of the underlaying
1628 rates. With a test of ~350 sequences in the test database it could
1629 be shown that the new fit gives the same result +/-1sek.
1630 The highest deviation was +5s the lowest -10s. You can now control
1631 the bahaviour with two resource values:
1632 MHEffectiveOnTime.FistBin: 3
1633 MHEffectiveOnTime.NumEvents: 12000
1634 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1635 from the resulting gamma candidates
1636
1637 - star: The Center histogram in MHHillas is now by default displayed
1638 with the colz draw-option
1639
1640 - ganymed: now produces valid error codes if failed
1641
1642 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1643 with the option "hadronness" instead of "area" or "both" if
1644 you want to use both cuts. The hadronness cut includes a fixed
1645 cut in hadronness (index 8) and a fixed cut in size (index 9).
1646
1647 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1648 the M3Long of the anti source to be not properly evaluated
1649 (actually is was evaluated as a unique random number) in case
1650 of optimization with anti-theta cut switched on. This might have
1651 lead to improper, but not necessarily wrong, optimization results.
1652
1653 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1654 how to use random forest
1655
1656 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1657 ganymed_onoff.rc. Seems to be unintentional that they were different.
1658
1659 - sponde: Since the introduction of the possibility to define a
1660 normalization energy instead of using the integral the default
1661 was not using the integral anymore but a normalization energy of
1662 1GeV. It is now the integral again.
1663
1664 - sponde: Fixed a problem in the weighting which did not allow
1665 a MC slope of -1.
1666
1667
1668
1669 *** Version 0.9.6 (2006/05/24)
1670
1671 - general: changed the binning of the azimuthal profile of the camera
1672 such that it is aligned with the 60deg boundaries.
1673
1674 - merpp: better handling of problems with the TH, TD part of the
1675 CC-REPORT for files older than 200507190 and 200412210
1676 respectively
1677
1678 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1679
1680 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1681
1682 - callisto: if an arrival time is extracted outside the fadc range is
1683 was set to the boundary before. Now a random number is assigned
1684 instead to avoid unfortunate coincidences of arrival times just
1685 by this arbitrary value.
1686
1687 - callisto: added a new option to callisto.rc which allows
1688 to set the maximum arrival time difference allowed for the
1689 badpixel algorithm to determin whether a pixels belongs to a shower:
1690 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1691
1692 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1693 to 0.9 as suggested by Stefan due to a recent study on the fraction
1694 of pixels surviving the image cleaning
1695
1696 - callisto: switched off error in case of "pulse is too much to the left"
1697
1698 - callisto: The extraction window is not adapted anymore. This means that
1699 the pulse is extracted from the full range. The draw-back is that the
1700 background (pedestal) will become slightly higher. Switching on/off
1701 the PulsePosCheck in the callisto.rc only effects filling the
1702 histograms.
1703 WARNING: If the pulse is too much to the left data is calibrated!
1704 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1705 in the database to make sure that your data is valid!
1706
1707 - star: Show also the number of stars correlated correctly by the
1708 starguider
1709
1710 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1711 than one off-source region in wobble-mode. To use it add the following to
1712 your ganymed_wobble.rc:
1713 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1714 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1715 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1716 + Cut1.ThetaCut: None
1717 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1718
1719 - ganymed: in the case the latest report is older than a default (currently
1720 one minute) and the current report will be skip the starguider
1721 correction and calibration will be reset. The maximum age can be
1722 setup from ganymed.rc by (minutes):
1723 MPointingDevCalc.MaxAge: 1.5
1724
1725 - ganymed: A first implementation showing all size-bins for the theta-sq
1726 resp. alpha-plots in a single tab automatically
1727
1728
1729
1730 *** Version 0.9.5.1 (2006/05/05)
1731
1732 - general: Added a new option "zdiff" to the Makefile which runs
1733 "cvs diff" as "make diff" would do, but with compression
1734
1735 - general: accelerated MTFillMatrix (used for eample in all training
1736 and optimization macros) by skipping some obsolete calles in the
1737 eventloop the first and second loop could be accelerated by ~20%
1738
1739 - general: Added a missing feature in the MFilterList class which
1740 prevented MFEnergySlope from working correctly in trainenergy.C
1741
1742 - general: Accelerated the random forest training and usage a bit
1743
1744 - merpp: Adapted to new raw data file format version 6
1745
1746 - merpp: fixed a problem with reading the starguider reports
1747 after 6.3.2006
1748
1749 - callisto: At some times six pixels had to be exchanged manually in the
1750 data. If the pixels to be swaped are both not found, an error was raised
1751 and calibration was stopped. Now it is assumed they are intentially not
1752 mapped and the Error has been changed to a Warning.
1753
1754 - star: Added new image cleaning based on the arrival time of the shower.
1755 The new cleaning can be accessed using the parameter "Time" instead of
1756 the the old one (like "Absolute) in the star.rc-file.
1757 Recommended parameters:
1758 + MImgCleanStd.CleanLevel1: 8.2
1759 + MImgCleanStd.CleanLevel2: 5
1760 + MImgCleanStd.CleanRings: 2
1761 + MImgCleanStd.KeepSinglePixels: No
1762
1763 - star: Simplified the calculation of the effective on time. By letting
1764 the fit start in the third bin the result should become more stable.
1765 The fit quality is now ignored for the theta-plot which is not used
1766 in the analysis later. Still better pre-cut which, for example,
1767 remove events triggered by car-light (rate changing on a short
1768 time-scale) are missing.
1769
1770 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1771 for optimization (kWeakSource) which is suggested by the Berlin
1772 people for weak sources.
1773
1774 - macros: plotdb.C:
1775 + if no dataset and no time-interval is given only sequences with
1776 an effective on-time above five minutes are plotted anymore
1777 + added a new tab "RelTime" displaying the relative on-time
1778 (effective on-time divided by the observation time)
1779
1780 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1781 the optimization became a lot faster
1782
1783 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1784 To display them just delete the pads displayed on top.
1785
1786 - ganymed: fixed a bug which could cause strange behaviour in wobble
1787 mode if no starguider information was available due to an incorrect
1788 initialization of the starguider calibration
1789
1790 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1791 be changed from within the plot. It can also be setup from the
1792 resource file using:
1793 + MHDisp.fScaleMin: 0.325
1794 + MHDisp.fScaleMax: 0.475
1795
1796 - ganymed, showplot: Fixed a problem with the fit to the off-data
1797 (HistOff) which could cause a time lag or an inifinite loop.
1798 The bug did not effect the results at all.
1799
1800 - sponde: Added a new tab showing the effective collection area after
1801 trigger (including the software trigger)
1802
1803 - sponde: MMcSpectrumWeight has a new option which allows to define
1804 the scaling factor not by the integral of the events but at
1805 a defined energy:
1806 e.g. MMcSpectrumWeight.NormEnergy: 200
1807
1808 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1809 eventloops the loop could be accelerated by ~20%
1810
1811
1812
1813 *** Version 0.9.5 (2006/03/13)
1814
1815 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1816 and added the standard Disp-parametrization
1817
1818 - macros: added a new macro datacenter/macros/plotstat.C allowing
1819 to plot statistics about the data processing
1820
1821 - macros: added a new macro to plot the muon correction coefficients
1822 versus period (macros/plot/mucal.C)
1823
1824 - showplot: path inflation for ganymed files was broken
1825
1826 - callisto: Fixed an important bug. When the number of saturating pixels
1827 were calculated the bad pixel information already available from the
1828 calibration was ignored. This yields wrong values in case pixels
1829 are broken and saturate all the time or randomly.
1830
1831 - callisto: Updated Muon calibration constants. Spline data now also uses
1832 different values for different periods
1833
1834 - star: The time-evolution shown in the effective on-time plot now displays
1835 the axis range (if there are no holes it should be similar to the
1836 effective on-time)
1837
1838 - star: Added two new image parameters:
1839 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1840 the three pixels next to the center of gravity and the size
1841 + MNewImagePar.fConcCore: The ratio of the signals of all
1842 pixels inside or touching the ellipse and the size
1843
1844 - ganymed: now stops in requested source isn't found in catalog file
1845
1846 - ganymed: Many improvements to the phi-plot in wobble mode:
1847 + with a template the ideal background is displayed
1848 + a possible camera inhomogeneity is taken into account
1849 + the anti theta cut is better supported
1850 + the phi cut is automatically calculated from the theta cut
1851 See the examples in ganymed_wobble.rc for more details.
1852
1853 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1854 times the bin-width instead of the absolute energy
1855
1856 - ganymed: New cuts for on/off and wobble mode
1857
1858 - ganymed: The smearing of the False Source plot has been increased
1859 to 0.06
1860
1861 - ganymed: The starguider calibration can now be changed from the
1862 resource file.
1863 See the examples in ganymed*.rc for more details.
1864
1865 - ganymed: added a new option for on-/off-observations
1866 MJCut.RandomSourcePosition
1867 If switched on the distribution of observation time of the source
1868 position in the camera is calculated from the on-data and randomly
1869 applied with this distrbution to the off-data.
1870
1871 - ganymed: by skipping some obsolete calles in the eventloop the
1872 first and second loop could be accelerated by ~20%
1873
1874 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1875 position in the off-data randomly according to its distribution in the
1876 on-data.
1877
1878
1879
1880 *** Version 0.9.4.3 (2006/02/13)
1881
1882 - general: Fixed a bug in most of the programs which prevented the
1883 compile date in the startup message to be displayed
1884
1885 - general: Simplified program calls. The following abbreviations
1886 are now possible:
1887 showlog callisto 55599
1888 showplot signal 55599
1889 star 55599
1890 callisto 55999
1891 ganymed 2
1892 In this cases the corrsponding root-, log-, sequence- or dataset-
1893 filename is automatically compiled using the default datacenter
1894 paths ("/magic/*")
1895
1896 - general: Fixed a long outstanding bug which made axis tick marks
1897 disappear if MDataFormula was used (eg. abs(x))
1898
1899 - general: Updated MMath with new functions to calculate the results of
1900 a exponential, logarithmic and powerlaw fits analytically.
1901
1902 - general: Updated some macros with comments:
1903 + macros/optim/optimdisp.C
1904 + macros/optim/optimenergy.C
1905 + macros/optim/optimwobble.C:
1906
1907 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1908 files) now allows adding a pre-cut like in the optimization. E.g. this
1909 is useful to perform g/h-separation cuts before training the random
1910 forest.
1911
1912 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1913 correctly assigned in the raw data assignement table. A fix to correct
1914 the assignment tabel have been implemented.
1915
1916 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1917 by 90, 180 and 270 deg.
1918
1919 - general: the macro plotdb.C now allows to highlight sequences belonging
1920 to a datset. For more details see the descritions in the macro.
1921
1922 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1923 of the display, it gave wrong results espacially for big sizes.
1924 Now the embedded canvas should always have a ratio width/height=3/2.
1925 The "Size" options have been updated with values fitting the 3/2
1926 size ratio.
1927
1928 - RanForest:
1929 + Updated the random forest classes to support also the
1930 regression method implemented by Thomas H.
1931 + added new tutorial macro how to train the random forest
1932 for energy estimation (macros/optim/rfenergyest.C)
1933 + new classes to train the random forest (still in development)
1934 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1935 + new tutorial macros for random forest training in macros/train
1936 trainenergy.C, traindisp.C, trainseparation.C
1937
1938 - mars: now allows to setup a cut in the resource file mars.rc to choose
1939 the events to be displayed, eg:
1940 Cut.Condition: {0} && {1}
1941 Cut.0: MHillas.fSize>100
1942 Cut.1: MHillas.fSize<900
1943
1944 - merpp: Made aware of the new .rep format 200510250. This includes
1945 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1946 the discriminator thresholds (MCameraTD) and the disciminator
1947 delays (MCameraTD). All of them come with the CC report and are therefor
1948 written to the CC tree.
1949
1950 - callisto: fixed a bug in the calculation of the arrival times in
1951 the Digital Filter. They were all shifted by the same amount
1952 fHiGainFirst. This caused an offset in the order of the position of
1953 the left border of the extraction window in the times calculated
1954 from high-gain and from low-gain. The bug effected only the absolute
1955 arrival times. The bug was there since 30.1.2005.
1956
1957 - callisto: Changed the ExtractionWindow for the pulse position check
1958 such that the camera inhomogeneity becomes as less as possible and
1959 comparable to the pulso position check switched off. More details
1960 on the study will be given at our result web-page.
1961
1962 - ganymed: ganymed.rc, ganymed_onoff.rc:
1963 changed to new cuts trained with 1ES1218 and Crab-data
1964 for maximum sigma*log10(excess)
1965
1966 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1967 a new option was implemented to estimate Disp (CalcDisp)
1968
1969 - ganymed: Implemented two new options which allow
1970 to overwrite the default path to search for the sequence files
1971 --ins=/magic/sequences
1972 and where to search for the image data
1973 --ind=/magic/data/star
1974
1975 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1976 dx/dy from the resource file by
1977 MSrcPosCorrect.Dx
1978 MSrcPosCorrect.Dy
1979
1980 - ganymed: fixed reading the source catalog. Only as many chars
1981 as the requested source name had were compared (If a source
1982 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1983 were requested it could happen that the coordinates of
1984 "1ES1218" were read) The source coordinates are now printed
1985 in addition to its name to the logging output.
1986
1987 - ganymed: changed the background fit in the case of a ThetaSq function
1988 from a polynomial to a exponential, this should give a big improvement
1989 for on-only analysis'
1990
1991 - ganymed/sponde: Calculation of the error of single size-/energy-
1992 bins now uses Li/Ma (5) instead of LiMa (17)
1993
1994 - sponde: Added a plot E^2*dN/dE
1995
1996 - sponde: The energy estimator plot should now show values like
1997 they are commonly used.
1998
1999 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
2000 (a powerlaw with cutoff didn't work before)
2001
2002
2003
2004 *** Version 0.9.4.2 (2005/10/01)
2005
2006 - general: added new tutorial macro macros/tutorials/threshold.C:
2007 how to calculate the threshold
2008
2009 - general: added a new game. Start it from the interpreter with
2010 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
2011 and MagicReversi)
2012
2013 - general: neighbor pixels in MGeoms are now sorted clockwise
2014
2015 - merpp: made aware of new format 20050829-0
2016
2017 - callisto: New scale factors from muon analysis, stored in new
2018 resource file resources/calibration.rc
2019
2020 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
2021 the eventloop if something went wrong. This is necessary for the
2022 automatic processing
2023
2024 - callisto: Implemented a new treatment for the time information
2025 developed by S.Ruegamer, this should give much better response than
2026 the old very primitive algorithm. This is especially important
2027 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
2028 treatment was buggy! As neighbor pixels to interpolate the
2029 arrival times always the pixels 0 to 5 were taken)
2030
2031 - callisto: In addition to the new treatment of arrival times the
2032 decision of the treatment whether a pixel contains shower
2033 information or not is used to improve the signal interpolation
2034 further. Previously interpolated pixels showed a non-zero signal
2035 do the peak searching signal extractors. Having a signal pixel
2036 beside raised the signal above the cleaning level. Thus the
2037 pixel survived cleaning to often but with a too low mean signal.
2038 By replacing empty pixels with a gaus (mean and rms from the
2039 corresponding Area entries in MPedPhotCam) this effect can
2040 be supressed.
2041
2042 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
2043 got lost when the events were stored by the calibration... fixed.
2044 (This was no problem for normal image cleaning because the pixel
2045 content was artificially set to 0 not surviving standard cleaning
2046 algorithm)
2047
2048 - callisto: Fixed a bug which caused the random and peak-search pedestal
2049 extracted with an extractor to be exchanged for the first (roughly)
2050 500 events (*Extractor and *ExtractorRndm).
2051 (They were simply exchanged in callisto.cc) This bug might have been
2052 introduced in Mars 0.9.4 when the order of calculation of the two
2053 types of pedestal in callisto got exchanged. The bug only effects
2054 the first seconds of data of each sequence.
2055
2056 - star: Taking the arrival time of Muons into account the calculation
2057 of the parameters could be made independant of the noise
2058 (pedestal rms). The dependance was due to the bias of the peak search
2059 extractor. Now only a ZA dependamcy is left which is not yet fully
2060 understood.
2061
2062 - ganymed: The sequences were still not sorted correctly in any case,
2063 because they were sorted by the full qualified path name. Now they
2064 are sorted by their sequence number.
2065
2066 - ganymed: new values for the spark-event-cut
2067
2068 - sponde: required missing MEnergyEst from ganymed.root... fixed.
2069
2070
2071
2072 *** Version 0.9.4.1 (2005/08/18)
2073
2074 - callisto: fixed some problems with the calibration in case of
2075 inteleaved events. Therefor the final and some intermediate
2076 fits are skipped which would take place on partly filled #
2077 histograms and gave wrong results or failed completely.
2078
2079 - callisto: If the intermediate finalization of the histograms
2080 calculating the mean charge of the calibration signal fails
2081 it is counted now and printed in PostProcess of MCalibCalcFromPast.
2082
2083 - ganymed: Fixed some bugs which caused problems in On-only mode.
2084 Still the false source plot doesn't give reasonable results.
2085
2086
2087
2088 *** Version 0.9.4 (2005/08/05)
2089
2090 - general: Fixed the ZA binning. It did not correctly fit the
2091 MC binning
2092
2093 - general: Added a class to correct for the missfocussing in
2094 April (MSrcPosCorrect)
2095
2096 - general: Random Forest energy estimator should now work properly
2097
2098 - general: MHCamera now displays the profiles in deg instead of mm
2099
2100 - general: MH::SetPalette offers a lot of new palettes
2101
2102 - general: MHillas - the case of CorrXY==0 is now handled properly
2103
2104 - general: implemented the possibility to change the line and
2105 marker style of a sky-grid drawn by MAstroCatalog
2106
2107 - general: Runs in sequences and datasets are now automatically
2108 ordered (it is assumed that the order of their filenames correctly
2109 represents the order of observations) to ensure correct reading
2110 of the subsystem data
2111
2112 - general: Runs cannot be added to a sequence twice anymore. Also
2113 Sequences cannot be added twice anymore to a dataset.
2114
2115 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2116 It gave wrong results by 1./2pi
2117
2118 - showplot: got a new option to start a root interpreter, too
2119
2120 - mars: now displays a rough estimate of Disp and the third moment
2121
2122 - mars: now displays the event time MTime if available
2123
2124 - mars: show muon parameters graphically
2125
2126 - mars: now the file to open can be given as commandline
2127 argument
2128
2129 - merpp: Added support for new arehucas version >= 200507190
2130 implementing values for three temperature sensors in the
2131 counting house (MCameraAUX) and the name of the HV settings file
2132 (MCameraHV).
2133
2134 - merrp: Also fixed some problems with wrong versions numbers stated
2135 by arehucas and implemented some fixed for old versions (<200407070)
2136
2137 - callisto: MCalibrationHiLoCam can now be printed from its context
2138 menu, eg in the TBrowser
2139
2140 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2141 - 1.39 (MExtractTimeAndChargeSpline)
2142 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2143 This is important mainly for timing studies.
2144
2145 - callisto: Changed limits in MHCalibrationChargeCalc from
2146 - -100.125 to -98 (fgChargeHiGainFirst)
2147 - 1899.875 to 1902. (fgChargeHiGainLast)
2148 - -100.25 to -99 (fgChargeLoGainFirst)
2149 - 899.75 to 901. (fgChargeLoGainLast)
2150 Introduced new limits:
2151 - fgNumLoGainBlackoutLimit: 0.05
2152 - fgLoGainBlackoutLimit: 3.5
2153 - fgLoGainPickupLimit: 3.5
2154
2155 - callisto: The handling of automatic weights for the digital filter
2156 has been improved. There are now new calibration weights special
2157 for Monte Carlo calibrations.
2158
2159 - callisto: Updated Muon scale with latest results (1% difference
2160 for most data, 5% for Mar/Apr'05)
2161
2162 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2163 was saturated and the blackout-events in the low-gain exceed the
2164 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2165 This excludes those pixels which have a saturating high-gain
2166 channel, but the low-gain switch does not switch often enough
2167 to make the distribution reliable.
2168
2169 - callisto: fix a bug counting the number of saturated events. Up to now,
2170 the number of saturated slices was counted (which is one for a not too
2171 high number), but for some (pathological) pixels, many more slices
2172 saturated and produced wrong limits.
2173
2174 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2175 + MCalibrationRelTimeCam.CheckFitResults: Yes
2176 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2177 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2178 + MCalibrationRelTimeCam.CheckOscillations: Yes
2179
2180 - callisto: introduce max. number of events for intercalibration,
2181 the rest gets skipped. Default: 4096
2182 The calibration causes too many un-reliable pixels if more
2183 than about 5000 events are treated (@500 Hz) because of the
2184 mode hopping of the VCSels. However, in the past, some
2185 calibration runs have been taken (erroneously) with more
2186 than 5000 events, especially the intensity scans where
2187 a good precision is needed.
2188
2189 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2190 photo-electrons for the spline extractor by 1-2% (correctly).
2191
2192 - callisto: The intercalibration is now done using a full f-factor
2193 method instead of a simple update. This makes things slower but
2194 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2195 changes.
2196
2197 - callisto: MPedestalY3 now uses the same extraction range as the data
2198 as calculated by MPedestalY2
2199
2200 - callisto: A check of the fraction of allowed unsuitable (10%) and
2201 unreliable (30%) pixels has been addded when the conversion is
2202 calculated from interleaved events
2203
2204 - star: fixed a bug which caused MEffectiveOnTime containers not to
2205 be written. In the worst case they were skipped almost all, in the
2206 best case they were all ok. It depends on how often the new value
2207 was assigned just with an event which was skipped later by another
2208 task
2209
2210 - star: new histograms MHPointing and MHRate
2211
2212 - star: New tab (Currents) displaying the time evolution of the mean
2213 DC currents
2214
2215 - star: New tab (MeanRms) displaying the time volution of the mean
2216 Pedestal Rms
2217
2218 - star: Output now contains MReportStarguider
2219
2220 - star: Improved muon analysis. Due to the absense of a constant
2221 for the gaus fit for arc width and the fact that the arcwidth
2222 plot was a histogram instead of a profile the resulting psf
2223 became pedestal rms dependant
2224
2225 - ganymed: added new plot (MHPhi) for wobble mode as described in
2226 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2227
2228 - ganymed: corrects now (correctly?) for the misspointing in
2229 May/April 05
2230
2231 - ganymed: Two new default templates for ganymed.rc are avilable:
2232 ganymed_onoff.rc and ganymed_wobble.rc
2233
2234 - ganymed: The first version of MFMagicCuts has been released
2235
2236 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2237
2238 - ganymed, sponde: There are two new options to determin the number
2239 of bins for the signal region (NumBinsSignal) and the number of
2240 total bins (NumBinsTotal) in the MHThetaSq histogram
2241
2242 - ganymed: optimized palettes for MHDisp
2243
2244 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2245 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2246 sqrt(2) to large
2247
2248 - ganymed: The false source plot (MHDisp) is now based on Disp
2249 and a background model determined in the first loop is
2250 subtracted
2251
2252 - ganymed: MFMagicCuts are now available in the cvs. The correct
2253 solution for the disp ambiguity problem is now calculated using
2254 the third moment. The third moment cut therefor is skipped.
2255
2256 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2257 already determined by the third moment along the major axis and
2258 so its actual sign is aligned along the major axis of the shower.
2259
2260 - ganymed: If starguider data is available it is taken into account
2261 when calculating the source position. This is especially important
2262 for wobble data at high zenith angles and culmination data.
2263
2264 - ganymed: If available the starguider data is taken into account as
2265 good as it is possible without a starguider calibration. To switch
2266 it off add
2267 MPointingDevCalc.MaxAbsDev: -1
2268 to your ganymed.rc
2269
2270 - sponde: the zenith angle distribution is now weighted instead of
2271 choosen by default. This gurantees higher statistics in the highest
2272 and lowest energy bins. To switch this behaviour off use...
2273
2274 - sponde: now automatically displays the energy threshold
2275
2276
2277
2278 *** Version 0.9.3 (2005/06/03)
2279
2280 - general: MMcEvt now derived from MMcEvtBasic which should
2281 have no influence on compatibility with older camera files
2282
2283 - general: Implemented a new option to MReadReports which allows
2284 to force reading of the first event of some trees (eg. Drive-tree)
2285 before any other tree.
2286
2287 - general: Made a fix to MPointingPosCalc which assumes that the
2288 run-type is real-data if Process is called before ReInit, such
2289 that also the very first Drive-events in a run are treated
2290 correctly.
2291
2292 - shoplot now displays the filename in the title bar of the window
2293
2294 - merpp: new options: --auto-time-start --auto-time-stop which
2295 allow to cut updating with slow-control at the start- or
2296 (previousle --auto-time only allowed: and) stop-time of
2297 the run stored in the runheader.
2298
2299 - callisto: changed default of fgFallTimeHiGain in
2300 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2301 already set as default in callisto_Dec04Jan05.rc
2302
2303 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2304 now changes the filename for new weights automatically for
2305 cosmics, MC and for different calibration colors.
2306
2307 - callisto: a problem with the order of some code cause the
2308 name of the weights file in MPedestalY2 to be ignored.
2309 Wrongly the calibration_UV weights were used instead
2310 of the cosmics weights set in callisto.rc.
2311
2312 - callisto: should allow ct1 pulser data when the color is
2313 explicitly set also for pretty new runs
2314
2315 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2316 to introduce an additional scale factor (should be around 1)
2317 to adapt for slight deviations in different extractors from
2318 the MC calibration. For MC calibrations the scale factor
2319 is fixed to 1
2320
2321 - callisto: MFCosmics should handle very high signals a bit
2322 more accurate now
2323
2324 - callisto: when calculating the mean pedestal rms for different
2325 pixel sizes or sectors also kUnsuitableEvt is now taken into
2326 account - not only kUnsuitableRun
2327
2328 - callisto: '-raw' option is now the default
2329
2330 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2331 This has the advantage that mean values in the calibration (eg
2332 arrival times) are calculated more accuratly.
2333
2334 - callisto: In the resource file callisto_Dec04Jan05.rc
2335 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2336
2337 - callisto: new Hi-/Lo-Gain intercalibration constants
2338 hilocalib_sp1.root and hilocalib_sp1_mc.root
2339
2340 - callisto: changed default for MJPedestalY2.MaxEvents
2341 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2342
2343 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2344 has changed from 9.0 to 6.0. This is necessary to exclude two very
2345 ringing pixels in September which - when kept - destroy the image
2346 cleaning around them (Markus G.)
2347
2348 - callisto: (!) The Muon analysis of all data taken so far has
2349 suggested that different extractors give slightly different
2350 absolute results after calibration, due to there different
2351 handling of the calibration- and cosmics pulse shape. Although
2352 the over all calibration seems to be a bit to pesimistic (or
2353 the MC seems to be a little bit - 3-5% - too much attenuated).
2354 There for correction factors have been introduced which correct
2355 the calibration constants by
2356 0.956937799 for Digital Filter (callisto.rc)
2357 and
2358 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2359 calibration. The main advantage is, that both data types can
2360 be easily analysed together and compared to the same MC sample.
2361 The factors are choosen such, that the reference is now a
2362 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2363
2364 - star: fixed a bug which caused the first bin of the histograms
2365 vs time to disapear in PostProcess. This gave wrong results
2366 on the screen. The output and all following programs not
2367 directly accessing the histograms haven't been affected
2368
2369 - star, ganymed: Made sure that always the first Drive-tree event
2370 is read and Processed before the first data event was read.
2371
2372 - ganymed: implemented the possibility to replace the standard
2373 false source plot with a different one. For example: If
2374 you want to use a Disp based FS plot use the resource:
2375 NameHistFS: MHDisp
2376 For details about the requirements of these plots look
2377 at the corresponding classes
2378
2379 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2380 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2381 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2382 case MAlphaFitter is setup correctly. For On-Only optimization
2383 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2384 RunOn() instead of Run(). For energy estimation MJOptimize
2385 has been replaced by MJOptimizeEnergy
2386
2387 - sponde: The input MC spectrum can now be weighted to fake a
2388 different spectrum. This is done via MMcSpectrumWeight. For
2389 more details see the class description and sponde.rc
2390
2391 - sponde: The paremeter comparsion plots are not scaled by
2392 their entries anymore. Instead the MC plot is scaled by using
2393 the result spectrum of the analysis. If the input MC spectrum
2394 and the result spectrum has different slopes the absolut
2395 normalization is normally wrong.
2396
2397
2398
2399 *** Version 0.9.2 (2005/05/20)
2400
2401 - general: Changed the default paths for calibrated data and image
2402 files. (The implemented access to these files doesn't yet exist)
2403
2404 - general: support for MRunIter has been removed from the job classes
2405 (use the setter functions of MSeqeunce instead)
2406
2407 - general: ProcessFile has been renamed to Process in all job classes,
2408 because ProcessFile is missleading
2409
2410 - general: The storage of the palette in MHCamera is now possible
2411
2412 - general: new bits describing unsuitable and unreliable pixels have
2413 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2414 kDeadPedestalRms, kFluctuatingArrivalTimes
2415
2416 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2417 versions newer than V200404070
2418
2419 - general: support for cc file versions newer than V200504130. Added
2420 support for active loads (MCameraActiveLoad) and central pixel
2421 (MCameraCentralPixel)
2422
2423 - general: added new histograms for image parameters versus size
2424 (MHVsSize)
2425
2426 - general: The eventloop now automatically calls PrintStatistics
2427
2428 - Status Display: Improved support for printing:
2429 + A default can now be set in .rootrc (for more details see
2430 MStatusDisplay::PrintPS)
2431 + A print dialog is opened so that printer and command line
2432 can be canged
2433
2434 - showlog: improved such that it handles different verbosity levels
2435 more accurate now. This mean you can suppress output when
2436 using showlog.
2437
2438 - showplot: improved
2439 + The new graphics formats have been implemented
2440 (pdf, svg, png, jpg and xpm)
2441 + Implemented an interface for printing. Because you can change
2442 the printing command from the command line you can use all
2443 the nice postscript tool. To print a booklet for example call:
2444 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2445 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2446 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2447
2448 - callisto: fixed a bug in the recognition of the calibration bit
2449 pattern. Concerns only intensity calibration. (The strength of the
2450 intensity has been updated in some cases)
2451
2452 - callisto: add a filter against PIN Diode events when running over
2453 calibration runs since some of the recent calibration runs have
2454 been taken with Pin Diode.
2455
2456 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2457 39943, 44833 in the calibration (MCalibColorSet)
2458
2459 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2460 been set to 1e-18 in callisto_Dec04_Jan05.rc
2461
2462 - callisto: in callisto_Dec04Jan05.rc: set value for
2463 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2464 statistics for the calculation of the mean pulse time
2465 of the cosmisc
2466
2467 - callisto: the charge limit in the calibration has been raised
2468 from 2.5 to 4.5
2469
2470 - callisto: new setup read from callisto.rc
2471 + MCalibCalcFromPast.fNumEventsDump
2472 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2473 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2474
2475 - callisto: MExtractTimeAndChargeSpline extractor:
2476 + The integration ranges were shifted by 0.2 FADC slices to the right.
2477 + unreliable handling of floating point values caused different
2478 results on different platform or with different compiler options:
2479 The new algorithm is numerically exact and more accurate because
2480 it doesn't calculate the integration position by multiple times
2481 adding the step-size (which results in numerical uncertanties
2482 exspecially if multiplied with large numbers)
2483 + A lot of fixes have been introduced which effects integrating the
2484 spline at the edges of the valid range. In this case any memory
2485 was randomly accessed. This behaviour can be tested replacing
2486 all MArrayF by TArrayF which perform a range check (but of course
2487 they are a lot slower)
2488 ! No result obtained with the Spline before can be trusted! Due to
2489 random memory access it might by completely random!
2490
2491 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2492 + extraction range in the high gain to 4.
2493 + weights file to cosmics_weights46.dat
2494
2495 - callisto:
2496 + introduce the check for fluctuating arrival times.
2497 + set charge limit to from 2.5 to 4.5
2498 + introduce asymmetric exclusion due to "deviating number of phes":
2499 Default: -9.0 +4.5
2500 + make deviating number of phes unsuitable (see David's findings).
2501
2502 - callisto: fixed the display of unsuitable pixels. The old change
2503 to a real profile in MHCamera broke it.
2504
2505 - callisto: The cosmics filter is used in MJCalibration now
2506 independant of the pulser color (formaly it was used only for
2507 CT1-pulser data). The threshold of number of max empty pixels
2508 has been raised from 2% to 5% in MJCalibration. The maximum
2509 fraction of rejected event is 50% otherwise the calibration has
2510 failed. The filter now ignores unsuitable pixels.
2511 Setup the filter from callisto.rc using "ContCosmics"
2512 (see MFCosmics::ReadEnv)
2513
2514 - callisto: changed default for fgOffsetFromLogain back
2515 from -2.8 to -1.8 in digital filter.
2516
2517 - callisto: for the common extractors
2518 + MExtractFixedWindow
2519 * MExtractTimeAndChargeSlidingWindow
2520 * MExtractTimeAndChargeSpline
2521 * MExtractTimeAndChargeDigitalFilter
2522 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2523 and fResolutionPerPheLoGain
2524
2525 - callisto: Updated the hi-/lo-gain intercalibration constants
2526 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2527 hilocalib_df6.root
2528
2529 - callisto: The default lo-gain extraction window for the
2530 MExtractTimeAndChargeSlidingWindow extractor has been increased
2531 from 6 to 8 to take the stretch of the pusle into account
2532
2533 - callisto (!!!): fixed an important bug in the setting of the
2534 incoming pedestal pointer to the signal extractor extracting
2535 pedestals. This bug caused the pedestals not to be subtracted
2536 correctly in the calibration afterwards. The effect was about 10%
2537 too high conversion factors for the digital filter and the spline
2538 and more than 40% for the sliding window.
2539 The bug existed since end of February! (Markus G.)
2540
2541 - star: added muon support to star. A new tab "MHMuonPar" is
2542 displayed. The lower right plot is an estimate of the point spread
2543 function. A reference value is displayed. To get the real PSF
2544 you must compare with MC. The setup for the muon analysis
2545 is done in star.rc. More informations can be found in
2546 MHSingleMuon and MHCalibParCalc
2547
2548 - star: The weather data is now displayed in star
2549
2550 - star: MEventRateCalc handles the calculation of the event rate more
2551 accurate now in case of the start of a new run inside a sequence
2552
2553 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2554 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2555 changed only minimally
2556
2557 - ganymed: (MJCut and MJOptimize) now displayes the number of
2558 excess events versus size. The energy estimation is done in
2559 MJSpectrum (sponde)
2560
2561 - ganymed: got support for using other variables than Alpha, eg. Theta.
2562 Therefor you need a class deriving from MHAlpha which supports
2563 this variable (one is already existing: MHTheta, which is now the
2564 default in ganymed). It is setup through ganymed.rc
2565
2566 - added a full featured spectrum program (sponde) which reads
2567 ganymed output and monte carlos and compiles a spectrum
2568
2569
2570
2571 *** Version 0.9.1 (2005/04/14)
2572
2573 - Fix bug on the arrival time reconstruction when using Digital
2574 Filter (in some marginal cases (10%) times were reconstructed shifted
2575 by 0.2 slices)
2576
2577 - all executables now return 2 where in previous versions -1 has
2578 been returned (gave problems with shell-scripts)
2579
2580 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2581 also done with a intercalibration input file
2582
2583 - a bug in the time fine adjustment of the digital filter has been fixed
2584
2585 - a lot of small fixes to calling TPad::Divide with a margin==0
2586
2587 - MStatusDisplay now shows the memory usage
2588
2589 - added a memory leak statistic after the eventloop
2590
2591 - MHadronness replaced by MParameterD
2592
2593 - MEnergyEst replaced by MParameterD
2594
2595 - wobble mode can now be switched on from the data-set
2596
2597 - switched on bad pixel detection for a pedestal level
2598 which is more than 5 times the variance
2599
2600 - Fixed default paths to be correct for the new data center
2601
2602 - Fixed handling of drive data. The pointing position in now
2603 copied to MPointingPos inside star for real and MC events
2604
2605 - made sure, that the sequences in a dataset are sorted by
2606 their number to ensure the correct synchronization
2607
2608 - added all resource files necessary to handle spline extraction
2609 of signal for the late 2004 and the early 2005 data
2610
2611 - update the reference lines for the december data
2612
2613 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2614 This is important for the Dec. and Jan. data where the calibration
2615 pulse position changes much.
2616
2617 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2618 filter. This corrects only an defective extraction of the MC at
2619 low-gain signals lower than 90 phes.
2620
2621 - fixed some slowdown in calibrating data with interleaved events from
2622 Jan and Dec. As a workaround made the pretty palette the default.
2623 The inverse Deep Blue Sea has a bug which slows down long calibration
2624 runs a lot.
2625
2626 - implemented new values from new starguider report as defined
2627 in TDAS00-07 V7.1 (eg SkyBrighness)
2628
2629 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2630 in starguider report (If you merpp the same reports with this version
2631 you'll get the correct units (arcmin) but a different result
2632 than with old versions (wrong units))
2633
2634 - Now the status display can also write PNG, JPEG and XPM (other file
2635 formats are still unsupported by root)
2636
2637 - added a lot of scripts and macros in directory datacenter used
2638 for automatic processing
2639
2640
2641
2642 *** Version 0.9 (2005/03/23)
2643
2644 - Calibration is now done autmatically into photo-electrons like
2645 decided by the Collaboration Board
2646
2647 - Reference lines in the display can be read from resource file
2648
2649 - Interlaced calibration events can be handled by callisto
2650
2651 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2652 and applied in callisto.
2653
2654 - class MJCalibTest can be called by callisto
2655
2656 - callisto can now run with three data types: rawdata, rootdata, MC
2657
2658 - added two classes mreport/MReportStarguider.cc and
2659 mreport/MReportStarguider.h for implementing starguider-data
2660
2661 - the output of merpp-update now contains starguider information:
2662 MReportStarguider and MTimeStarguider
2663
2664 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2665 values were lower than they should. This was more visible for high
2666 energy (Size) events.
2667
2668 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2669
2670 - added a new loop to callisto to support the correct extraction of
2671 the pedestal and pedestal rms through the signal extractor
2672
2673 - added class to perform fourier tranformation of a hexagonal structure
2674 (MHexagonalFT)
2675
2676 - added class to perform fourier tranformation of a hexagonal structure
2677 in a tasklist (MHexagonalFTCalc) example: hft.C
2678
2679 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2680 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2681 small pixels, example: extendcam.C
2682
2683 - added possibility to write data to memory (TTree) using MWriteRootFile
2684
2685 - added possibility to read a TTree stored only in memory by MReadTree
2686
2687 - new classes to deal with the interleaved calibration events:
2688 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2689
2690 - implemented filters to callisto to skip calibration events
2691
2692 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2693 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2694 the slices by statistics
2695 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2696 signal extractor without randomization
2697 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2698 with the signal extractor with randomization (extraction window is
2699 randomly fixed)
2700 The three kind of pedestal is not yet implemented (for speed reasons) as
2701 long as nobody really needs it:
2702 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2703 extracted with the signal extractor with randomization
2704
2705 - callisto now finds the pulse position in the data automatically
2706
2707 - implemented data reduction in calibrated data by reducing the precision
2708 of the stored floating point values (pedestal, rms and signal) to
2709 roughly 0.5%
2710
2711 - fixed showplot to make file format conversion (eg. converting a
2712 status display stored in a root file into a postscript file) in
2713 batch mode possible:
2714 showplot -b --save-as-ps[=outfile.ps] infile.root
2715
2716 - Allow class names as part of filter rules, eg
2717 (MFSupercuts) && (MHillas.fSize>100)
2718
2719 - fixed a lot of stuff to allow all programs to process MonteCarlo
2720 camera files.
2721
2722 - enhanced possibility to debug reading of resource file
2723
2724 - MDataChain should handle priorities of operator more
2725 accurate now
2726
2727 - completely revised the container in which the signal is stored
2728 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2729 * the new implementation is faster and
2730 * needs less storage space
2731
2732 - FIRST version which can process Monte Carlos through the
2733 whole chain of programs (callisto, star, etc)
2734
2735 - implemented new image parameters for the border length of
2736 the shower image (MNewImagePar2)
2737
2738 - implemented wobble-mode in ganymed
2739
2740 - new class (MJOptimize) taking care of all optimization processes
2741
2742
2743
2744 *** Version 0.8.6 (2004/10/05)
2745
2746 - New combined signal and time extractor
2747 MExtractTimeAndChargeDigitalFilter
2748
2749 - The Report for the trigger section in the CC run summary has been
2750 updated, and now the IPRs (Individual Pixel Rates) are available.
2751
2752 - new macros for database interaction: filldotrun.C, filldotrbk.C
2753
2754 - added new program which can convert colored output which was redirected
2755 into a file back into colored text (for example to display it with
2756 more): showlog
2757
2758 - added new program to display an MStatusArray of plots (stored with
2759 MStatusDisplay) from a file: showplot
2760
2761 - Added support for Sequences (MSequence). Sequences are blocks of run
2762 files containing the same calibration and belonging to the same
2763 source
2764
2765 - Added a new task (MTaskEnv) which can be used in setup files to switch
2766 between different tasks (for example to choose a signal extractor)
2767
2768 - Implemented automatic file splitting in MWriteRootFile
2769
2770 - After image cleaning an island index is assigned to all used pixels.
2771 The index corresponds to the order of the islands in size.
2772
2773 - added a cleaning which takes signal height _and_ arrival time into
2774 account: probability cleaning (for more details see MImgCleanStd)
2775
2776 - added a cleaning which takes takes the absolute number of photons
2777 times the area ratio as cleaning level
2778 (for more details see MImgCleanStd)
2779
2780 - Changed calculation of image parameters such, that it can be done
2781 for all used pixels or the pixels with a defined island index only
2782
2783 - implemented new image parameters displaying the number of islands,
2784 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2785
2786 - event display in executable changed to support also calibrated files
2787 (done with MJCalibrateSignal)
2788
2789 - added program doing the calibration and the signal extraction
2790 and signal calibration: callisto Most part of the setup is done
2791 by a resource file: callisto.rc
2792
2793 - implemented support for pixels with negative IDs (Raw file format
2794 version 4)
2795
2796 - implemented an new option in merpp (--auto-time) to get the time
2797 range for cc and/or caco data from the run header of the raw data
2798
2799 - New star-program (star and MJStar). Taking calibrated data from
2800 callisto/MJCalibrateSignal as input. The setup is done through
2801 a resource file: star.rc
2802
2803 - Added possibility to setup the eventloop in the mars-executable
2804 Camera Display by a resource file: mars.rc
2805
2806 - The the mars-executable Camera Display can now also read
2807 calibrated data files written by callisto/MJCalibrateSignal
2808
2809 - Added a new class which can calculate the source position in
2810 the camera from a pointing model known to be correct and
2811 the pointing model used for observations (MSrcPosFromModel)
2812
2813 - added a new version of the class calculating the effective on-time
2814 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2815 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2816 MHTimeDiffTheta.
2817
2818 - added the possibility to count how often a signal is above (or
2819 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2820 can replace MHTriggerLvl0)
2821
2822 - added ore convinient ways to set the axis-titles of your histograms
2823 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2824 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2825
2826
2827
2828 *** Version 0.8.5 (2004/08/06)
2829
2830 - new Signal Extractors: MExtractFixedWindowSpline
2831 and MExtractAmplitudeSpline
2832
2833 - implementes interleave in merpp to be able to merpp parts of a file
2834
2835 - implemented force-functionality to merpp
2836
2837 - star display to display star catalogs (MAstroCatalog)
2838
2839 - star display to 'mirror' stars to the camera (MAstroCamera)
2840
2841 - implemented a new cleaning option which allows cleaning scaled with
2842 the real ratio of the rms depending on the pixel size, not only the
2843 square root of the pixelsize (MImgCleanStd, MCameraData)
2844
2845 - removed obsolete MBlind* classes
2846
2847 - Signal extractor taking the AB flag into account implemented (this makes
2848 an odd number of slices for signal extraction possible
2849 (MExtractSignalABcorr)
2850
2851 - implemented a class extracting the pedestal from the raw-data (events)
2852 itself using empty lo-gain (MpedCalcFromLoGain)
2853
2854 - Added mean values to MPedPhotCam
2855
2856 - Added Makefile for Darwin (this OS is NOT officially supported!)
2857
2858
2859
2860 *** Version 0.8.4 (2004/04/19)
2861
2862 - new fast arrival time extractor using cubic splines:
2863 MExtractTimeFastSpline
2864
2865 - implementes multi-argument support in MDataChain
2866 ("pow(a, b)")
2867
2868 - implemented double reference support in MDataChain
2869 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2870
2871 - added support in MF for expressiond like
2872 "MHillas.fWidth<2*<MHillas.fLength"
2873
2874 - MDataChain is now able to support variables like [0], [1], ...
2875 which can be used in fit functions as parameters. The interface
2876 is implemented through the new virtual function
2877 MParContainer::SetVariables
2878
2879 - added new class MArrivalTimeCam/MArrivalTimePix:
2880 Storage containers to hold the ArrivalTime of the camera/pixel
2881
2882 - added new classes for the calibration of relative arrival times:
2883 MCalibrationRelTimePix and MCalibrationRelTimeCam
2884
2885 - added new classes to extract the signal of the blind pixel and the
2886 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2887
2888 - added new classes for the bad-pixels treatment (MBadPixels*)
2889 which are more powerfull than the old ones (MBlindPixel*)
2890 and will replace them.
2891
2892 - added filter against cosmics: MFCosmics
2893
2894 - added new class MArrivalTimeCalc2:
2895 Calculates the arrival time as the signal weighted mean of the time
2896 slices in the maximum window
2897
2898 - added a new macro call pointspreadfucntion.C that fits with a 2D
2899 gaussian the DC spot for an star. It gives you the RMS of
2900 the PSF and the center of the star, very useful for misspointing
2901 studies.
2902
2903 - added support for multi-telescope camera files. Added classes
2904 MStereoCalc and MStereoPar, classes to calculate and store shower
2905 parameters calculated from the data of two telescopes, for the MC
2906 studies regarding the MAGIC clone.
2907
2908 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2909 MC data calibrated in photons instead of ADC counts.
2910
2911 - added three macros to show the calibration and analysis chain of
2912 MC data. The macro starmc.C does both calibration and analysis, producing
2913 an output containing Hillas parameters for each event. The macro
2914 mccalibrate.C does just the calibration and writes out a file containing
2915 pixel information in photons instead of FADC data. The macro starmc2.C
2916 reads in such a file and produces an output with Hillas parameters.
2917
2918 - added MPedPhotCalc to compute pedestals in units of photons, see
2919 macro pedphotcalc.C
2920
2921 - added all class to perform the calibration, see macro calibration.C
2922
2923 - added class MFFT to perform Fast Fourier Transforms
2924
2925 - added class MSimulatedAnnealing to perform simulated annealing
2926 minimizations
2927
2928 - added new macro bootcampstandardanalysis.C which holds the skeleton
2929 of the analysis chain discussed in the december bootcamp.
2930
2931 - added support for DAQ raw data file format V2
2932
2933 - implemented an arbitrary time stamp for the events from raw-data
2934 files with file version<3. It is calculated from the run number,
2935 the date of start and the FADC clock tick from the first module
2936
2937 - implemented the correct decoding of the event time-stamp
2938 coming from the DAQ for raw-data files with file-version>2
2939
2940 - added a new classes storing the pedestals in units of photons:
2941 MPedPhotPix, MPedPhotCam
2942
2943 - added support for DC current files from the camera control
2944
2945 - added support for start- and stop-time when merpping report files
2946
2947 - added MReportCC storing the weather data from the CC-REPORT
2948
2949 - added class to fill trainings and test matrices (MTFillMatrix)
2950
2951 - added a filter performing a software trigger (MFSoftwareTrigger)
2952
2953 - Added classes to perform parts of the standard analysis (Jobs):
2954 + MJPedestals
2955 + MJCalibration
2956 + MJExtractSignal
2957 Note: All of them are preliminary!
2958
2959 - Added Iterator to iterate over files giving only the run-number
2960
2961 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2962 the evolution of a sector vs time
2963
2964
2965
2966 *** Version 0.8.3 (2003/12/05)
2967
2968 - adapted Random Forest classes to allow the use with MC
2969 multi-telescope files which can be produced with the coming
2970 camera version 0.7.
2971
2972 - added classes to read and interprete central control report files
2973 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2974
2975 - enhanced merpp (the executable) to support .raw and .rep files.
2976
2977 - added classes for light calibration (MCalibration* and
2978 MHCalibration*) by Markus Gaug. Further work has to be and will
2979 be done soon.
2980
2981 - Added a preliminary 'synchronizer' (MReadReports) which will
2982 replace MReadMarsFile as soon as it is finished.
2983
2984 - Added a tutorial macro demonstrating how report files are merpped
2985 and how they can be read from the root file in the correct order
2986 of time (readrep.C)
2987
2988 - Added a generalized histogram (similar to MH3) called MVsTime
2989 which allows to plot variables (or rules - MDataChain - of
2990 variables) vs time. For an example have a look at tempvstime.C.
2991
2992 - Changed the name of the event trees:
2993 + Events --> Events
2994 + PedEvents --> Pedestals
2995 + CalEvents --> Calibration
2996
2997 - changed name of MTime in the event trees from MRawEvtTime to MTime
2998
2999 - added displaying the sector indices to the mars event display
3000
3001 - Magic Online Analysis (MOnA) implemented in a first version
3002 (see mona.cc, MOnlineDump and MOnlineDisplay)
3003
3004 - added classes to calculate event rate
3005 (preliminary: MEventRateCalc, MEventRate)
3006
3007 - added new executable 'readdaq' to read *.raw files from the DAQ directly
3008
3009 - added classes dealing with the telescope pointing position (MPointing*)
3010
3011 - implemented the 'final' Mars time stamp based on some experiences with
3012 the new 'Synchonizer'
3013
3014
3015
3016 *** Version 0.8.2 (2003/11/10)
3017
3018 - accelerated standard analysis by a factor of 6-8 ...
3019 + doing precalculations in MGeomCam for the pixel area ratio
3020 + creating a look up table for the single pixels in MCerPhotEvt
3021
3022 - added task to calculates weights in case you want to 'change'
3023 the energy spectrum of a monte carlo file
3024 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
3025
3026 - added a new executable star which implements the
3027 star.C macro as precompiled executable. Currently a flexible
3028 setup is not possible, but a 'input card' setup will follow.
3029
3030 - Starting to implement Multi-Telescope-Support based on the
3031 upcomming camera version 0.7. The base for a general support
3032 is implemented and the star-functionality is proven to work.
3033
3034 - Replaced Event-Display in and Camera-Display in the Mars GUI
3035 executable by a more convinient display base on MStatusDisplay.
3036
3037 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
3038
3039
3040
3041 *** Version 0.8.1 (2003/10/20)
3042
3043 - added signal subtraction for pure on data by means of fitting
3044 the background in the off region or by performing a combined
3045 signal/background fit. Provides necessary histograms for
3046 obtaining energy spectra and a light curve.
3047
3048 - added classes to perform and study the selection of the
3049 2nd Level Trigger on MC data (example in triglvl2.C macro)
3050
3051 - added pedestal calculation
3052
3053 - implemented "democratic cleaning" (tail cut value proportional
3054 to pixel area) according to Wolfgang's suggestion.
3055
3056 - added Sigmabar treatment (calculation and basic histogramming)
3057
3058 - added basic routines to apply padding
3059
3060 - added first implementation of MARS-based source visibility plotter
3061 (needs to be linked against slalib, preliminary version)
3062
3063 - enhanced functionality of data chains: random numbers, conversion
3064 functions and access to MHMatrix objects
3065
3066 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
3067 numbers under certain circumstances (runs with 0 events included)
3068
3069 - fixed a bug in the general filter MF (didn't work on some systems
3070 at all)
3071
3072 - fixed a bug in chaining files, which caused the analysis to crash or
3073 ignore files
3074
3075 - implemented more geometry classes describing the parameters used
3076 to simulate the PMT camera
3077
3078 - added new Monte Carlo classes containing the setup of the different
3079 programs in the MC chain.
3080
3081 - added a (preliminary) general task to evaluate chi-square of a given
3082 parameter in an eventloop.
3083
3084 - first implementation of a container describing the observatory
3085 location (Long, Lat, etc)
3086
3087 - added Random Forest - method for g/h-separation
3088
3089 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3090 (this means, that it is compiling, but not yet fully tested)
3091
3092 - added a new status display which can show the present status
3093 of histograms while an eventloop is running (MStatusDisplay,
3094 an example can be found at status.C)
3095
3096 - reorganized directories:
3097 classes describing the image --> mimage
3098 classes containing Monte Carlo Histograms --> mhistmc
3099 classes for Random Forest method --> mranforest
3100
3101 - added (event-)weights to fill histograms
3102
3103 - colors in logging output to screen
3104
3105 - changes to the Image Parameter declaration:
3106 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3107 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3108 + MHillasExt now derives from MParContainer instead of MHillas
3109 --> Files written with the old definition are more or less unreadable
3110
3111 - reading of reflector files
3112
3113 - display data from reflector files in the camera
3114
3115 - implemented currents (and display them in the camera)
3116
3117 - logarithmic scale in camera
3118
3119 - added class to iterate through directory contents (MDirIter)
3120
3121
3122
3123 *** Version 0.8 (2002/11/18)
3124
3125 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3126
3127 - corrected 48(!) wrong entries in the Next Neighbor table of the
3128 Magic Camera (all in the inner part of the outer ring, mostly
3129 missing a single NN)
3130
3131 - Fixed a bug in the table describing the Next Neighbours of the
3132 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3133 have any neighbour)
3134
3135 - changed trigrate.C: now it calculates the pure NSB triggers from
3136 a camera file (generated with no showers), so there is no need
3137 to introduce them by hand in the BgR array (for more details
3138 please ask Abelardo)
3139
3140 - added MHHadronness (and MHadronness) as a general facility to evaluate
3141 the quality of a gamma-hadron seperation method
3142
3143 - changed MWriteAsciiFile to accept rules (MDataChain)
3144
3145 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3146 must be replaced by calles to MWriteAsciiFile::AddColumn and
3147 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3148 changed.
3149
3150 - Implemented generalized event-matrices (one row per event)
3151 (MHMatrix)
3152
3153 - implemented the one dimensional composite probabilities
3154 (MHCompProb, MCompProbCalc, comprob.C)
3155
3156 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3157 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3158
3159 - Added a camera display displaying the pixel numbers to the
3160 event display gui.
3161
3162 - Added Monte Carlo Informations to event display gui
3163
3164 - Changed the camera display to display the pixel numbering
3165
3166 - Added three buttons to the camera display to change the palette
3167
3168 - Added the number of used and core pixels after image cleaning
3169 to MHillas
3170
3171 - Changed the algorithm used in MHillas according to TDAS 02-03
3172
3173 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3174
3175 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3176
3177 - Added fCosDeltaAlpha to MHillasSrc
3178
3179 - The numbers of photons used to calculate fConc and fConc1 in
3180 MHillasExt are now scaled with the pixel size, so that one get
3181 a four times smaller value for the bigger pixels in the outer ring.
3182
3183 - added new task to smooth the camera contents (MCameraSmooth)
3184
3185 - added possibility to use interpolated pixel values for blind pixels
3186 instead of removing it completely from the analysis
3187
3188 - Implemented the possibility to save the whole eventloop with
3189 its setup to a file. This information can be read and from
3190 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3191 and MEvtLoop::MakeMacro. If you find something not working, please
3192 report - this stuff is still in a beta phase.
3193
3194 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3195 file having crab starfield, but also for all following files - fixed
3196
3197 - MTaskList::PrintStatistics can now be instructud to print also the
3198 title, too: use PrintStatistics(0, kTRUE)
3199
3200 - Changed the image cleaning so that pixels with to many 'used'
3201 neighbors are left used (to get rid of 'holes' in events)
3202
3203 - Introduced more output to the camera displays
3204
3205 - Added an array of histograms (eg one hist per run), MHArray
3206
3207 - Added a _preliminary_ version of the reader for CT1 PreProc files
3208 (MCT1ReadPreProc)
3209
3210 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3211 (thanks to Raquel)
3212
3213 - added the first energy estimator (MEnergyEstParam, estimate.C,
3214 estfit.C) using a parametrization
3215
3216 - Added some new Monte Carlo paremeter containers used to store
3217 setup information from the MC chain (MMcConfigRunHeader,
3218 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3219
3220
3221
3222 *** Version 0.7 (2002/04/30)
3223
3224 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3225 the pedestal mean value was saved incorrectly. For files from
3226 this versions we substract 0.5 from the pedestal mean.
3227 WARNING: This may effect your results, so don't wonder...
3228
3229 - First implementation of an algorithm using only triggered events
3230 for the collection area calculation
3231
3232 - Ascii Output can now also be used for parameter containers which
3233 doesn't overload MParCointainer::AsciiWrite
3234
3235 - The Ascii Output is now also capable of writing single data members
3236 of one container
3237
3238 - You are now able to change the order of the values written to the
3239 ascii file
3240
3241 - You can now specify a conversion factor for each data member written
3242 to an ascii file. This may be usefull to change the units of the
3243 data member (eg. degrees instead of millimeters in case of the
3244 hillas parameters)
3245
3246 - Replaced old MHillas by a new structure which allows you to extend
3247 the parameters stored in MHillas very easily:
3248 see MHillas and MHillasExt
3249
3250 - Added classes to handle source dependancy of image parameters:
3251 see MHillasSrc
3252
3253 - Added container (MBinning) to have a standard input for the binning
3254 in different histograms (eg. the Energy bins should be the same in
3255 all histograms)
3256
3257 - Changed Hillas histograms from mm to deg
3258
3259 - Added the flexible binning to the hillas histograms
3260
3261 - Added a filter for the alpha parameter (MFAlpha)
3262
3263 - It is now possible to write single data members of a class object to
3264 an output stream instead of the whole container only
3265
3266 - Added a generalized filter for a data member:
3267 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3268
3269 - Added a generalized Filter parser for more difficult filter rules
3270 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3271
3272 - Added new Monte Carlo histograms:
3273 MHMcEnergyImpact and MHMcEfficiency
3274
3275 - Added many new histograms needed for the flux calculation.
3276
3277 - Added a generalized histograms which can fill and show up to three
3278 data members in either a one-, two- or three-dimensional histogram, eg:
3279 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3280
3281 - Added:
3282 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3283 * calculation of <Theta> as a function of time (MHThetabarTime)
3284 they are needed in the flux calculation in
3285 order to select for a given bin in Theta (or time) the appropriate
3286 effective collection area, which is assumed to be given as a function
3287 of Theta and the true energy
3288
3289 - Added calculation of the migration matrix in the energy
3290 (MHMcEnergyMigration):
3291 the migration matrix describes the migration from the true (E_true)
3292 to the estimated energy (E_est); it is needed to determine the
3293 distribution of E_true from the measured distribution of E_est
3294 by unfolding
3295
3296 - changed the color palette in the camera display to DeapSea.
3297
3298
3299
3300 *** Version 0.6 (2002/01/15)
3301
3302 - Introduce the option of disable pixels (MBlindPixels and
3303 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3304 able to deal with Star Field NSB.
3305
3306 - Fixed a bug in the pedestals substraction
3307
3308 - Introduced verbosity levels
3309
3310 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3311
3312 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3313 work correctly (thanks to Abelardo)
3314
3315 - Introduced correct treatment of the diffuse Night Sky Background
3316 and NSB (MMcPedestalNSB)
3317
3318 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3319
3320 - Introduced MMcRunHeaders which contains monte carlo run informations
3321
3322 - Added a 'Print'-Task (MPrint) which calls the Print function
3323 of a parameter container for each event
3324
3325 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3326
3327 - changes to be more efficient with root 3.02/06
3328
3329 - root 3.02/06 fixes:
3330 + the memory leak when reading MRawEvtData
3331 + loosing more time than necessary to update the progress bar
3332
3333 - MWriteAsciiFile is now capable of writing more than one container
3334 in a line. For example: To be able to write Monte Carlo and
3335 Hillas values (energy and alpha) in one line.
3336
3337
3338
3339 *** Version 0.5 (2001/11/06)
3340
3341 - Added new GUI functionality (Analysis)
3342
3343 - Added a camera display to be able to display events in the camera
3344 together with the calculated hillas ellipse
3345
3346 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3347 object at any state of the analysis, so that the output are several
3348 states
3349
3350 - Fixed a bug in the collection area error calculation
3351 (Thanks to Ciro and Abelardo)
3352
3353 - Fixed a bug which causes merpp to crash in some environments
3354
3355 - Implemented auto enabling scheme for Branches to speed up reading
3356 a lot (see MReadTree and MTask)
3357
3358 - Fixed a bug in the Histogram classes which caused histograms to
3359 be written to a file by MWriteRootFile without request
3360
3361 - changed the object I/O from the old stylish root I/O to the new
3362 'auto evolution scheme' This was done only for classes which are not
3363 yet used in Monte Carlo files, so that these files are still readable.
3364
3365 - Added support for a progress bar in MEvtLoop and MReadTree
3366 (see the Analysis Window in Mars for an example)
3367
3368 - Fixed a bug in the package creation which disturbed the conversion
3369 between a mars version unpacked from a tar file and the repository.
3370
3371 - Changed the code to writer merpped (converted into root format)
3372 raw files, to get faster (around 10%)
3373
3374
3375
3376 *** Version 0.4 (2001/09/20)
3377
3378 - This release is made to compile on a root version >= 3.00
3379
3380 - Fixed a bug which causes MReadTree to read the first file only
3381
3382 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3383
3384 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3385
3386 - Added a task to write several container to a root file (MWriteRootFile)
3387
3388 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3389
3390 - Added calculation of the collection area (MMcCollectionAreaCalc)
3391
3392 - fixed some bugs in the Hillas calculation
3393
3394 - added filters to be able to control the task execution dependent on
3395 a parameter (for example: the number of level 1 triggers in a MC-file)
3396
3397
3398
3399 *** Version 0.3 (2001/04/23)
3400
3401 - Many demo macros added
3402
3403 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3404
3405 - Hillas Calculation added
3406
3407 - Standard image cleaning available
3408
3409 - MReadTree is now able to handle more than one file
3410 (Remark: of the same structure)
3411
3412 - Now we are able to display events in a first version of the
3413 Camera event display. To do this we must run the macro
3414 "macros/readCT1.C" to read data from CT1.
3415
3416
3417
3418 *** Version 0.2 (2001/01/24)
3419
3420 - First Implementation of a Gui to read the raw data. Start the
3421 gui with the command mars.
3422
3423
3424
3425 *** Version 0.1 (2000/12/20)
3426
3427 - First official release 0.1
3428
3429 - Changes:
3430
3431 + changed calling style of MRawPixelIterator from do...while to
3432 while-loop
Note: See TracBrowser for help on using the repository browser.