source: trunk/MagicSoft/Mars/ganymed.rc@ 7699

Last change on this file since 7699 was 7656, checked in by tbretz, 19 years ago
*** empty log message ***
File size: 7.2 KB
Line 
1# ==========================================================================
2#############################################################################
3# ==========================================================================
4# General
5# ==========================================================================
6#############################################################################
7# ==========================================================================
8
9# -------------------------------------------------------------------------
10# Use this if you want to setup the logging stream for the jobs
11# (overwrites command line options)
12# -------------------------------------------------------------------------
13#MLog.VerbosityLevel: 2
14#MLog.DebugLevel: 1
15#MLog.NoColors: yes
16
17# ==========================================================================
18#############################################################################
19# ==========================================================================
20# Cuts
21# ==========================================================================
22#############################################################################
23# ==========================================================================
24
25# -------------------------------------------------------------------------
26# Use this if you want to write output to somewhere here you can give
27# the output path
28# -------------------------------------------------------------------------
29#MJCuts.PathOut: .
30
31# -------------------------------------------------------------------------
32# Use this to setup binnings. For more details see: MBinning::ReadEnv
33# -------------------------------------------------------------------------
34BinningAlpha.Raw: 36 0 90
35BinningFalseSource.Raw: 91 -1.5 1.5
36#BinningTheta.Raw: 50 0 60 cos
37BinningWidth.Raw: 50 0 1
38BinningLength.Raw: 25 0 1
39BinningDist.Raw: 25 0 2
40BinningMaxDist.Raw: 25 0 2
41
42# -------------------------------------------------------------------------
43# Using the starguider for pointing correction.
44# To switch it off use "MPointingDevCalc.MaxAbsDev: -1"
45# -------------------------------------------------------------------------
46#MPointingDevCalc.MaxAbsDev: 15
47#MPointingDevCalc.NumMinStars: 8
48#MPointingDevCalc.NsbLevel: 3.0
49#MPointingDevCalc.NsbMin: 30
50#MPointingDevCalc.NsbMax: 60
51#MPointingDevCalc.Dx -7
52#MPointingDevCalc.Dy 16
53
54# -------------------------------------------------------------------------
55# Setup the misfocussing correction
56# -------------------------------------------------------------------------
57#MSrcPosCorrect.Dx: 0
58#MSrcPosCorrect.Dy: 0
59
60# -------------------------------------------------------------------------
61# Setup fit mode and ranges
62# -------------------------------------------------------------------------
63#MAlphaFitter.SignalIntegralMax: 15
64#MAlphaFitter.SignalFitMax: 25
65#MAlphaFitter.BackgroundFitMin: 35
66#MAlphaFitter.BackgroundFitMax: 75
67#MAlphaFitter.ScaleMin: 35
68#MAlphaFitter.ScaleMax: 80
69#MAlphaFitter.PolynomOrder: 2
70#MAlphaFitter.ScaleMode: None
71
72# -------------------------------------------------------------------------
73# Define here which histogram class to use to determin the signal.
74# Currently availyble: MHAlpha, MHTheta <default>
75# -------------------------------------------------------------------------
76#MJCut.NameHist: MHAlpha
77
78# -------------------------------------------------------------------------
79# To get a meaningfull false source plot in wobble mode use magic cuts
80# and the following two lines.
81# -------------------------------------------------------------------------
82MJCut.NameHistFS: MHDisp
83
84MHDisp.Smearing: 0.06
85#MHDisp.Wobble: Yes
86#MHDisp.ScaleMin: 0.325
87#MHDisp.ScaleMax: 0.475
88
89# -------------------------------------------------------------------------
90# To get use a random source position in the off data with the distribution
91# in the camera of the on-data
92# -------------------------------------------------------------------------
93#MJCut.RandomSourcePosition: Yes
94
95# -------------------------------------------------------------------------
96# There are three cuts:
97# Cut0: After energy estimation, before writing summary file
98# Cut1: After writing summary file before filling false source plots
99# Cut2: After filling false source plots before filling alpha plots
100# Cut3: After filling alpha plots (eg. Alpha cuts) for image parameter
101# display
102# -------------------------------------------------------------------------
103Cut0.Inverted: Yes
104Cut1.Inverted: Yes
105Cut2.Inverted: Yes
106Cut3.Inverted: Yes
107
108# Get rid of triangular events...
109Cut0.Condition: ({0} || {1}) && {2} && {3} && {4} && {5} && {6}
110Cut0.0: MImagePar.fNumSatPixelsHG < 1
111Cut0.1: MHillas.GetArea*(MGeomCam.fConvMm2Deg^2) > (0.003*MImagePar.fNumSatPixelsHG) + 0.0325
112Cut0.2: MNewImagePar.fNumUsedPixels>5
113Cut0.3: MNewImagePar.fLeakage1 < 0.3
114Cut0.4: MImagePar.fNumSatPixelsLG<2
115Cut0.5: MImagePar.fNumIslands<3
116Cut0.6: log10(MNewImagePar.fConc1) < (-0.371)*log10(MHillas.fSize) + 0.596
117
118# ---------- SETUP FOR ONOFF-MODE -----------
119MAlphaFitter.ScaleMin: 0.137
120MAlphaFitter.ScaleMax: 0.640
121MAlphaFitter.BackgroundFitMin: 0.137
122MAlphaFitter.BackgroundFitMax: 1.000
123MAlphaFitter.PolynomOrder: 1
124MAlphaFitter.ScaleMode: OffRegion
125MAlphaFitter.SignalFunction: ThetaSq
126
127Cut1.Condition: MFMagicCuts
128Cut1.ThetaCut: None
129Cut1.Param0: 1.3245
130Cut1.Param1: 0.22
131Cut1.Param2: 0.215
132Cut1.Param3: 5.486
133Cut1.Param4: 0.0897
134Cut1.Param5: -0.07
135Cut1.Param6: 8.2957
136Cut1.Param7: 0.8677
137
138# ---------- SETUP FOR WOBBLE-MODE -----------
139#MAlphaFitter.ScaleMode: none
140#MAlphaFitter.BackgroundFitMin: 0.09
141#MAlphaFitter.BackgroundFitMax: 0.25
142#MAlphaFitter.SignalFunction: ThetaSq
143#Cut1.Condition: MFMagicCuts
144#Cut1.ThetaCut: Off
145#Cut1.Param0: 1.221
146#Cut1.Param1: 0.233161
147#Cut1.Param2: 0.234233
148#Cut1.Param3: 5.23611
149#Cut1.Param4: 0.109593
150#Cut1.Param5: -0.095321
151#Cut1.Param6: 13.425
152#Cut1.Param7: 1.04343
153
154# Be carefull: The spectrum might be done with a different binning
155# This might change the scale factor
156MHThetaSq.NumBinsSignal: 3
157MHThetaSq.NumBinsTotal: 75
158
159# -------------------------------------------------------------------------
160# Setup cuts in false source plot
161# -------------------------------------------------------------------------
162#MHFalseSource.DistMin: 0.55
163#MHFalseSource.DistMax: 0.55
164#MHFalseSource.DWMin: 0.55
165#MHFalseSource.DWMax: 0.55
166
167# -------------------------------------------------------------------------
168# Use this to executa a task (eg to calc hadronness) before Cut1
169# -------------------------------------------------------------------------
170# CalcHadronness: MRanForestCalc
171# CalcHadronness.FileName: rf-separation.root
172# CalcHadronness.NameOutput: Hadronness
173# CalcHadronness.Debug: No
174
175# -------------------------------------------------------------------------
176# Use this to executa a task (eg to calc disp) before Cut1
177# -------------------------------------------------------------------------
178# CalcDisp: MRanForestCalc
179# CalcDisp.FileName: rf-disp.root
180# CalcDisp.NameOutput: Disp
181# CalcDisp.Debug: No
182# Cut1.CalcDisp: No
Note: See TracBrowser for help on using the repository browser.