| 1 | #ifndef MARS_MCalibrationQEPix
|
|---|
| 2 | #define MARS_MCalibrationQEPix
|
|---|
| 3 |
|
|---|
| 4 | #ifndef MARS_MCalibrationPix
|
|---|
| 5 | #include "MCalibrationPix.h"
|
|---|
| 6 | #endif
|
|---|
| 7 |
|
|---|
| 8 | #ifndef ROOT_TArrayF
|
|---|
| 9 | #include "TArrayF.h"
|
|---|
| 10 | #endif
|
|---|
| 11 |
|
|---|
| 12 | #ifndef ROOT_TArrayC
|
|---|
| 13 | #include "TArrayC.h"
|
|---|
| 14 | #endif
|
|---|
| 15 |
|
|---|
| 16 | #ifndef MARS_MCalibrationCam
|
|---|
| 17 | #include "MCalibrationCam.h"
|
|---|
| 18 | #endif
|
|---|
| 19 |
|
|---|
| 20 | class MCalibrationQEPix : public MCalibrationPix
|
|---|
| 21 | {
|
|---|
| 22 | private:
|
|---|
| 23 |
|
|---|
| 24 | static const Float_t gkDefaultQEGreen; //! Default QE at 520 nm (now set to: 0.192)
|
|---|
| 25 | static const Float_t gkDefaultQEBlue; //! Default QE at 460 nm (now set to: 0.27 )
|
|---|
| 26 | static const Float_t gkDefaultQEUV; //! Default QE at 370 nm (now set to: 0.285)
|
|---|
| 27 | static const Float_t gkDefaultQECT1; //! Default QE at 370 nm (now set to: 0.285)
|
|---|
| 28 | static const Float_t gkDefaultQEGreenErr; //! Uncertainty Def. QE at 520 nm (now set to: 0.05)
|
|---|
| 29 | static const Float_t gkDefaultQEBlueErr; //! Uncertainty Def. QE at 460 nm (now set to: 0.07)
|
|---|
| 30 | static const Float_t gkDefaultQEUVErr; //! Uncertainty Def. QE at 370 nm (now set to: 0.07)
|
|---|
| 31 | static const Float_t gkDefaultQECT1Err; //! Uncertainty Def. QE at 370 nm (now set to: 0.07)
|
|---|
| 32 |
|
|---|
| 33 | TArrayF fQEBlindPixel; // Calibrated QEs (Blind Pixel Method)
|
|---|
| 34 | TArrayF fQEBlindPixelVar; // Variance cal. QEs (Blind Pixel Method)
|
|---|
| 35 | TArrayF fQECombined; // Calibrated QEs (Combined Method)
|
|---|
| 36 | TArrayF fQECombinedVar; // Variance cal. QEs (Combined Method)
|
|---|
| 37 | TArrayF fQEFFactor; // Calibrated QEs (F-Factor Method)
|
|---|
| 38 | TArrayF fQEFFactorVar; // Variance cal. QEs (F-Factor Method)
|
|---|
| 39 | TArrayF fQEPINDiode; // Calibrated QEs (PIN Diode Method)
|
|---|
| 40 | TArrayF fQEPINDiodeVar; // Variance cal. QEs (PIN Diode Method)
|
|---|
| 41 |
|
|---|
| 42 | Float_t fAvNormBlindPixel; // Normalization w.r.t. default QE (Blind Pixel Method)
|
|---|
| 43 | Float_t fAvNormBlindPixelVar; // Variance norm. w.r.t. def. QE (Blind Pixel Method)
|
|---|
| 44 | Float_t fAvNormCombined; // Normalization w.r.t. default QE (Combined Method)
|
|---|
| 45 | Float_t fAvNormCombinedVar; // Variance norm. w.r.t. def. QE (Combined Method)
|
|---|
| 46 | Float_t fAvNormFFactor; // Normalization w.r.t. default QE (F-Factor Method)
|
|---|
| 47 | Float_t fAvNormFFactorVar; // Variance norm. w.r.t. def. QE (F-Factor Method)
|
|---|
| 48 | Float_t fAvNormPINDiode; // Normalization w.r.t. default QE (PIN Diode Method)
|
|---|
| 49 | Float_t fAvNormPINDiodeVar; // Variance norm. w.r.t. def. QE (PIN Diode Method)
|
|---|
| 50 | Float_t fAverageQE; // Average QE for Cascade spectrum (default 0.18)
|
|---|
| 51 |
|
|---|
| 52 | TArrayC fValidFlags; // Bit-field for valid flags, one array entry for each color
|
|---|
| 53 | Byte_t fAvailableFlags; // Bit-field for available flags
|
|---|
| 54 |
|
|---|
| 55 | enum { kBlindPixelMethodValid, kFFactorMethodValid,
|
|---|
| 56 | kPINDiodeMethodValid, kCombinedMethodValid,
|
|---|
| 57 | kAverageQEBlindPixelAvailable, kAverageQEFFactorAvailable,
|
|---|
| 58 | kAverageQEPINDiodeAvailable, kAverageQECombinedAvailable };
|
|---|
| 59 |
|
|---|
| 60 | void AddAverageBlindPixelQEs( const MCalibrationCam::PulserColor_t col, Float_t &wav, Float_t &sumw );
|
|---|
| 61 | void AddAverageCombinedQEs ( const MCalibrationCam::PulserColor_t col, Float_t &wav, Float_t &sumw );
|
|---|
| 62 | void AddAverageFFactorQEs ( const MCalibrationCam::PulserColor_t col, Float_t &wav, Float_t &sumw );
|
|---|
| 63 | void AddAveragePINDiodeQEs ( const MCalibrationCam::PulserColor_t col, Float_t &wav, Float_t &sumw );
|
|---|
| 64 |
|
|---|
| 65 | const Float_t GetAvNormBlindPixelRelVar() const;
|
|---|
| 66 | const Float_t GetAvNormCombinedRelVar() const;
|
|---|
| 67 | const Float_t GetAvNormFFactorRelVar() const;
|
|---|
| 68 | const Float_t GetAvNormPINDiodeRelVar() const;
|
|---|
| 69 |
|
|---|
| 70 | public:
|
|---|
| 71 |
|
|---|
| 72 | static const Float_t gkDefaultAverageQE; //! Default QE folded into Cascade spectrum (now set to: 0.18)
|
|---|
| 73 | static const Float_t gkDefaultAverageQEErr; //! Uncertainty Def. QE Cascade spectrum (now set to: 0.02)
|
|---|
| 74 |
|
|---|
| 75 | MCalibrationQEPix(const char *name=NULL, const char *title=NULL);
|
|---|
| 76 | ~MCalibrationQEPix() {}
|
|---|
| 77 |
|
|---|
| 78 | void Clear(Option_t *o="");
|
|---|
| 79 |
|
|---|
| 80 | // Getters
|
|---|
| 81 |
|
|---|
| 82 | const Float_t GetAverageQE ( const Float_t zenith=0. ) const;
|
|---|
| 83 | const Float_t GetAverageQERelVar( const Float_t zenith=0. ) const;
|
|---|
| 84 |
|
|---|
| 85 | Float_t GetDefaultQE ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 86 | Float_t GetDefaultQERelVar ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 87 | Float_t GetQEBlindPixel ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 88 | Float_t GetQEBlindPixelErr ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 89 | Float_t GetQEBlindPixelRelVar ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 90 | Float_t GetQECascadesBlindPixel ( const Float_t zenith=0.) const;
|
|---|
| 91 | Float_t GetQECascadesBlindPixelErr ( const Float_t zenith=0.) const;
|
|---|
| 92 | Float_t GetQECascadesBlindPixelVar ( const Float_t zenith=0.) const;
|
|---|
| 93 | Float_t GetQECascadesCombined ( const Float_t zenith=0.) const;
|
|---|
| 94 | Float_t GetQECascadesCombinedErr ( const Float_t zenith=0.) const;
|
|---|
| 95 | Float_t GetQECascadesCombinedVar ( const Float_t zenith=0.) const;
|
|---|
| 96 | Float_t GetQECascadesFFactor ( const Float_t zenith=0.) const;
|
|---|
| 97 | Float_t GetQECascadesFFactorErr ( const Float_t zenith=0 ) const;
|
|---|
| 98 | Float_t GetQECascadesFFactorVar ( const Float_t zenith=0 ) const;
|
|---|
| 99 | Float_t GetQECascadesPINDiode ( const Float_t zenith=0.) const;
|
|---|
| 100 | Float_t GetQECascadesPINDiodeErr ( const Float_t zenith=0.) const;
|
|---|
| 101 | Float_t GetQECascadesPINDiodeVar ( const Float_t zenith=0.) const;
|
|---|
| 102 | Float_t GetQECombined ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 103 | Float_t GetQECombinedErr ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 104 | Float_t GetQECombinedRelVar ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 105 | Float_t GetQEFFactor ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 106 | Float_t GetQEFFactorErr ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 107 | Float_t GetQEFFactorRelVar ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 108 | Float_t GetQEPINDiode ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 109 | Float_t GetQEPINDiodeErr ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 110 | Float_t GetQEPINDiodeRelVar ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 111 |
|
|---|
| 112 | Bool_t IsAverageQEBlindPixelAvailable () const;
|
|---|
| 113 | Bool_t IsAverageQECombinedAvailable () const;
|
|---|
| 114 | Bool_t IsAverageQEFFactorAvailable () const;
|
|---|
| 115 | Bool_t IsAverageQEPINDiodeAvailable () const;
|
|---|
| 116 | Bool_t IsBlindPixelMethodValid () const;
|
|---|
| 117 | Bool_t IsBlindPixelMethodValid ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 118 | Bool_t IsCombinedMethodValid () const;
|
|---|
| 119 | Bool_t IsCombinedMethodValid ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 120 | Bool_t IsFFactorMethodValid () const;
|
|---|
| 121 | Bool_t IsFFactorMethodValid ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 122 | Bool_t IsPINDiodeMethodValid () const;
|
|---|
| 123 | Bool_t IsPINDiodeMethodValid ( const MCalibrationCam::PulserColor_t col ) const;
|
|---|
| 124 |
|
|---|
| 125 | // Setters
|
|---|
| 126 | void SetAverageQE ( const Float_t f ) { fAverageQE = f; }
|
|---|
| 127 | void SetAvNormBlindPixel ( const Float_t f ) { fAvNormBlindPixel = f; }
|
|---|
| 128 | void SetAvNormBlindPixelVar ( const Float_t f ) { fAvNormBlindPixelVar = f; }
|
|---|
| 129 | void SetAvNormCombined ( const Float_t f ) { fAvNormCombined = f; }
|
|---|
| 130 | void SetAvNormCombinedVar ( const Float_t f ) { fAvNormCombinedVar = f; }
|
|---|
| 131 | void SetAvNormFFactor ( const Float_t f ) { fAvNormFFactor = f; }
|
|---|
| 132 | void SetAvNormFFactorVar ( const Float_t f ) { fAvNormFFactorVar = f; }
|
|---|
| 133 | void SetAvNormPINDiode ( const Float_t f ) { fAvNormPINDiode = f; }
|
|---|
| 134 | void SetAvNormPINDiodeVar ( const Float_t f ) { fAvNormPINDiodeVar = f; }
|
|---|
| 135 | void SetAverageQEBlindPixelAvailable ( const Bool_t b=kTRUE );
|
|---|
| 136 | void SetAverageQECombinedAvailable ( const Bool_t b=kTRUE );
|
|---|
| 137 | void SetAverageQEFFactorAvailable ( const Bool_t b=kTRUE );
|
|---|
| 138 | void SetAverageQEPINDiodeAvailable ( const Bool_t b=kTRUE );
|
|---|
| 139 | void SetBlindPixelMethodValid ( const Bool_t b, const MCalibrationCam::PulserColor_t col);
|
|---|
| 140 | void SetCombinedMethodValid ( const Bool_t b, const MCalibrationCam::PulserColor_t col);
|
|---|
| 141 | void SetFFactorMethodValid ( const Bool_t b, const MCalibrationCam::PulserColor_t col);
|
|---|
| 142 | void SetPINDiodeMethodValid ( const Bool_t b, const MCalibrationCam::PulserColor_t col);
|
|---|
| 143 | void SetQEBlindPixel ( Float_t f, MCalibrationCam::PulserColor_t col) { fQEBlindPixel [col] = f; }
|
|---|
| 144 | void SetQEBlindPixelVar ( Float_t f, MCalibrationCam::PulserColor_t col) { fQEBlindPixelVar[col] = f; }
|
|---|
| 145 | void SetQECombined ( Float_t f, MCalibrationCam::PulserColor_t col) { fQECombined [col] = f; }
|
|---|
| 146 | void SetQECombinedVar ( Float_t f, MCalibrationCam::PulserColor_t col) { fQECombinedVar [col] = f; }
|
|---|
| 147 | void SetQEFFactor ( Float_t f, MCalibrationCam::PulserColor_t col) { fQEFFactor [col] = f; }
|
|---|
| 148 | void SetQEFFactorVar ( Float_t f, MCalibrationCam::PulserColor_t col) { fQEFFactorVar [col] = f; }
|
|---|
| 149 | void SetQEPINDiode ( Float_t f, MCalibrationCam::PulserColor_t col) { fQEPINDiode [col] = f; }
|
|---|
| 150 | void SetQEPINDiodeVar ( Float_t f, MCalibrationCam::PulserColor_t col) { fQEPINDiodeVar [col] = f; }
|
|---|
| 151 |
|
|---|
| 152 | // Updates
|
|---|
| 153 | Bool_t UpdateBlindPixelMethod();
|
|---|
| 154 | Bool_t UpdateCombinedMethod ();
|
|---|
| 155 | Bool_t UpdateFFactorMethod ();
|
|---|
| 156 | Bool_t UpdatePINDiodeMethod ();
|
|---|
| 157 |
|
|---|
| 158 | ClassDef(MCalibrationQEPix, 1) // Container Quantum Efficieny Calibration Results Pixel
|
|---|
| 159 | };
|
|---|
| 160 |
|
|---|
| 161 | #endif
|
|---|
| 162 |
|
|---|