source: trunk/MagicSoft/Mars/mjobs/MJCalibration.cc@ 4308

Last change on this file since 4308 was 4304, checked in by reyes, 20 years ago
*** empty log message ***
File size: 40.2 KB
Line 
1/* ======================================================================== *\
2!
3! *
4! * This file is part of MARS, the MAGIC Analysis and Reconstruction
5! * Software. It is distributed to you in the hope that it can be a useful
6! * and timesaving tool in analysing Data of imaging Cerenkov telescopes.
7! * It is distributed WITHOUT ANY WARRANTY.
8! *
9! * Permission to use, copy, modify and distribute this software and its
10! * documentation for any purpose is hereby granted without fee,
11! * provided that the above copyright notice appear in all copies and
12! * that both that copyright notice and this permission notice appear
13! * in supporting documentation. It is provided "as is" without express
14! * or implied warranty.
15! *
16!
17!
18! Author(s): Thomas Bretz, 1/2004 <mailto:tbretz@astro.uni-wuerzburg.de>
19! Markus Gaug, 02/2004 <mailto:markus@ifae.es>
20!
21! Copyright: MAGIC Software Development, 2000-2004
22!
23!
24\* ======================================================================== */
25/////////////////////////////////////////////////////////////////////////////
26//
27// MJCalibration
28//
29// Do one calibration loop over serious of runs with the same pulser
30// colour and the same intensity. The following containers (rectangular) and
31// tasks (ellipses) are called to produce an MCalibrationChargeCam and to
32// update the MCalibrationQECam: (MCalibrate is not called from this class)
33//
34//Begin_Html
35/*
36<img src="images/CalibClasses.gif">
37*/
38//End_Html
39//
40// Different signal extractors can be set with the command SetExtractor()
41// Only extractors deriving from MExtractor can be set, default is MExtractSlidingWindow
42//
43// Different arrival time extractors can be set with the command SetTimeExtractor()
44// Only extractors deriving from MExtractTime can be set, default is MExtractTimeSpline
45//
46// At the end of the eventloop, plots and results are displayed, depending on
47// the flags set (see DisplayResult())
48//
49// If the flag SetFullDisplay() is set, all MHCameras will be displayed.
50// if the flag SetDataCheckDisplay() is set, only the most important ones are displayed
51// Otherwise, (default: SetNormalDisplay()), a good selection of plots is given
52//
53// If the flag SetDataCheck() is set, the calibration is used as in the data check at
54// La Palma, which mean especially running on raw data files.
55//
56// The absolute light calibration devices Blind Pixel and PIN Diode can be switched on
57// and off with the commands:
58//
59// - SetUseBlindPixel(Bool_t )
60// - SetUsePINDiode(Bool_t )
61//
62// See also: MHCalibrationChargePix, MHCalibrationChargeCam, MHGausEvents
63// MHCalibrationChargeBlindPix, MHCalibrationChargePINDiode
64// MCalibrationChargePix, MCalibrationChargeCam, MCalibrationChargeCalc
65// MCalibrationChargeBlindPix, MCalibrationChargePINDiode,
66// MCalibrationQECam, MBadPixelsPix, MBadPixelsCam
67//
68// If the flag RelTimeCalibration() is set, a calibration of the relative arrival
69// times is also performed. The following containers (rectangular) and
70// tasks (ellipses) are called to produce an MCalibrationRelTimeCam used by
71// MCalibrateTime to correct timing offset between pixels: (MCalibrateTime is not
72// called from this class)
73//
74//Begin_Html
75/*
76<img src="images/RelTimeClasses.gif">
77*/
78//End_Html
79//
80// Different arrival time extractors can be set directly with the command SetTimeExtractor(MExtractor *)
81//
82// See also: MHCalibrationRelTimePix, MHCalibrationRelTimeCam, MHGausEvents
83// MCalibrationRelTimePix, MCalibrationRelTimeCam
84// MBadPixelsPix, MBadPixelsCam
85//
86/////////////////////////////////////////////////////////////////////////////
87#include "MJCalibration.h"
88
89#include <TFile.h>
90#include <TStyle.h>
91#include <TCanvas.h>
92#include <TSystem.h>
93
94#include "MLog.h"
95#include "MLogManip.h"
96
97#include "MRunIter.h"
98#include "MParList.h"
99#include "MTaskList.h"
100#include "MEvtLoop.h"
101
102#include "MHCamera.h"
103#include "MGeomCam.h"
104
105#include "MPedestalCam.h"
106#include "MCalibrationCam.h"
107#include "MCalibrationQECam.h"
108#include "MCalibrationChargeCam.h"
109#include "MCalibrationChargePINDiode.h"
110#include "MCalibrationChargeBlindPix.h"
111#include "MCalibrationChargeCalc.h"
112
113#include "MHGausEvents.h"
114#include "MHCalibrationCam.h"
115#include "MHCalibrationChargeCam.h"
116#include "MHCalibrationChargeBlindPix.h"
117#include "MHCalibrationRelTimeCam.h"
118#include "MCalibrationRelTimeCam.h"
119#include "MCalibrationRelTimeCalc.h"
120
121#include "MReadMarsFile.h"
122#include "MRawFileRead.h"
123#include "MGeomApply.h"
124#include "MBadPixelsMerge.h"
125#include "MBadPixelsCam.h"
126#include "MExtractTime.h"
127#include "MExtractor.h"
128#include "MExtractPINDiode.h"
129#include "MExtractBlindPixel.h"
130#include "MExtractSlidingWindow.h"
131#include "MExtractTimeSpline.h"
132#include "MFCosmics.h"
133#include "MContinue.h"
134#include "MFillH.h"
135
136#include "MArrivalTimeCam.h"
137
138#include "MStatusDisplay.h"
139
140ClassImp(MJCalibration);
141
142using namespace std;
143
144const Int_t MJCalibration::gkIFAEBoxInaugurationRun = 20113;
145// --------------------------------------------------------------------------
146//
147// Default constructor.
148//
149// - Sets fRuns to 0, fExtractor to NULL, fTimeExtractor to NULL, fColor to kNONE,
150// fDisplay to kNormalDisplay, fRelTime to kFALSE, fDataCheck to kFALSE,
151// - SetUseBlindPixel()
152// - SetUsePINDiode()
153//
154MJCalibration::MJCalibration(const char *name, const char *title)
155 : fRuns(0), fExtractor(NULL), fTimeExtractor(NULL),
156 fColor(MCalibrationCam::kNONE), fDisplayType(kNormalDisplay),
157 fRelTimes(kFALSE), fDataCheck(kFALSE)
158{
159
160 fName = name ? name : "MJCalibration";
161 fTitle = title ? title : "Tool to create the calibration constants for one calibration run";
162
163 SetUseBlindPixel();
164 SetUsePINDiode();
165
166}
167
168
169// --------------------------------------------------------------------------
170//
171// Display the results in MStatusDisplay:
172//
173// - Add "Calibration" to the MStatusDisplay title
174// - Retrieve the MGeomCam from MParList
175// - Initialize the following MHCamera's:
176// 1) MCalibrationPix::GetMean()
177// 2) MCalibrationPix::Sigma()
178// 3) MCalibrationChargePix::GetRSigma()
179// 4) MCalibrationChargePix::GetRSigmaPerCharge()
180// 5) MCalibrationChargePix::GetPheFFactorMethod()
181// 6) MCalibrationChargePix::GetMeanConvFADC2Phe()
182// 7) MCalibrationChargePix::GetMeanFFactorFADC2Phot()
183// 8) MCalibrationQEPix::GetQECascadesFFactor()
184// 9) MCalibrationQEPix::GetQECascadesBlindPixel()
185// 10) MCalibrationQEPix::GetQECascadesPINDiode()
186// 11) MCalibrationQEPix::GetQECascadesCombined()
187// 12) MCalibrationQEPix::IsAverageQEFFactorAvailable()
188// 13) MCalibrationQEPix::IsAverageQEBlindPixelAvailable()
189// 14) MCalibrationQEPix::IsAverageQEPINDiodeAvailable()
190// 15) MCalibrationQEPix::IsAverageQECombinedAvailable()
191// 16) MCalibrationChargePix::IsHiGainSaturation()
192// 17) MCalibrationPix::GetHiLoMeansDivided()
193// 18) MCalibrationPix::GetHiLoSigmasDivided()
194// 19) MCalibrationChargePix::GetHiGainPickup()
195// 20) MCalibrationChargePix::GetLoGainPickup()
196// 21) MCalibrationChargePix::GetHiGainBlackout()
197// 22) MCalibrationChargePix::GetLoGainBlackout()
198// 23) MCalibrationPix::IsExcluded()
199// 24) MBadPixelsPix::IsUnsuitable(MBadPixelsPix::kUnsuitableRun)
200// 25) MBadPixelsPix::IsUnsuitable(MBadPixelsPix::kUnreliableRun)
201// 26) MBadPixelsPix::IsUncalibrated(MBadPixelsPix::kHiGainOscillating)
202// 27) MBadPixelsPix::IsUncalibrated(MBadPixelsPix::kLoGainOscillating)
203// 28) MCalibrationChargePix::GetAbsTimeMean()
204// 29) MCalibrationChargePix::GetAbsTimeRms()
205//
206// If the flag SetFullDisplay() is set, all MHCameras will be displayed.
207// if the flag SetDataCheckDisplay() is set, only the most important ones are displayed
208// and otherwise, (default: SetNormalDisplay()), a good selection of plots is given
209//
210void MJCalibration::DisplayResult(MParList &plist)
211{
212 if (!fDisplay)
213 return;
214
215 //
216 // Update display
217 //
218 TString title = fDisplay->GetTitle();
219 title += "-- Calibration ";
220 title += fRuns->GetRunsAsString();
221 title += " --";
222 fDisplay->SetTitle(title);
223
224 //
225 // Get container from list
226 //
227 MGeomCam &geomcam = *(MGeomCam*)plist.FindObject("MGeomCam");
228
229 // Create histograms to display
230 MHCamera disp1 (geomcam, Form("%s%s","Charge",(fRuns->GetRunsAsFileName()).Data()),
231 "Fitted Mean Charges");
232 MHCamera disp2 (geomcam, Form("%s%s","SigmaCharge",(fRuns->GetRunsAsFileName()).Data()),
233 "Sigma of Fitted Charges");
234 MHCamera disp3 (geomcam, Form("%s%s","RSigma",(fRuns->GetRunsAsFileName()).Data()),
235 "Reduced Sigmas");
236 MHCamera disp4 (geomcam, Form("%s%s","RSigmaPerCharge",(fRuns->GetRunsAsFileName()).Data()),
237 "Reduced Sigma per Charge");
238 MHCamera disp5 (geomcam, Form("%s%s","NumPhes",(fRuns->GetRunsAsFileName()).Data()),
239 "Nr. of Phe's (F-Factor Method)");
240 MHCamera disp6 (geomcam, Form("%s%s","ConvFADC2Phes",(fRuns->GetRunsAsFileName()).Data()),
241 "Conversion Factor (F-Factor Method)");
242 MHCamera disp7 (geomcam, Form("%s%s","TotalFFactor",(fRuns->GetRunsAsFileName()).Data()),
243 "Total F-Factor (F-Factor Method)");
244 MHCamera disp8 (geomcam, Form("%s%s","CascadesQEFFactor",(fRuns->GetRunsAsFileName()).Data()),
245 "Cascades QE (F-Factor Method)");
246 MHCamera disp9 (geomcam, Form("%s%s","CascadesQEBlindPix",(fRuns->GetRunsAsFileName()).Data()),
247 "Cascades QE (Blind Pixel Method)");
248 MHCamera disp10(geomcam, Form("%s%s","CascadesQEPINDiode",(fRuns->GetRunsAsFileName()).Data()),
249 "Cascades QE (PIN Diode Method)");
250 MHCamera disp11(geomcam, Form("%s%s","CascadesQECombined",(fRuns->GetRunsAsFileName()).Data()),
251 "Cascades QE (Combined Method)");
252 MHCamera disp12(geomcam, Form("%s%s","FFactorValid",(fRuns->GetRunsAsFileName()).Data()),
253 "Pixels with valid F-Factor calibration");
254 MHCamera disp13(geomcam, Form("%s%s","BlindPixelValid",(fRuns->GetRunsAsFileName()).Data()),
255 "Pixels with valid BlindPixel calibration");
256 MHCamera disp14(geomcam, Form("%s%s","PINdiodeValid",(fRuns->GetRunsAsFileName()).Data()),
257 "Pixels with valid PINDiode calibration");
258 MHCamera disp15(geomcam, Form("%s%s","CombinedValid",(fRuns->GetRunsAsFileName()).Data()),
259 "Pixels with valid Combined calibration");
260 MHCamera disp16(geomcam, Form("%s%s","Saturation",(fRuns->GetRunsAsFileName()).Data()),
261 "Pixels with saturated Hi Gain");
262 MHCamera disp17(geomcam, Form("%s%s","ConversionMeans",(fRuns->GetRunsAsFileName()).Data()),
263 "Conversion HiGain.vs.LoGain Means");
264 MHCamera disp18(geomcam, Form("%s%s","ConversionSigmas",(fRuns->GetRunsAsFileName()).Data()),
265 "Conversion HiGain.vs.LoGain Sigmas");
266 MHCamera disp19(geomcam, Form("%s%s","HiGainPickup",(fRuns->GetRunsAsFileName()).Data()),
267 "Number Pickup events Hi Gain");
268 MHCamera disp20(geomcam, Form("%s%s","LoGainPickup",(fRuns->GetRunsAsFileName()).Data()),
269 "Number Pickup events Lo Gain");
270 MHCamera disp21(geomcam, Form("%s%s","HiGainBlackout",(fRuns->GetRunsAsFileName()).Data()),
271 "Number Blackout events Hi Gain");
272 MHCamera disp22(geomcam, Form("%s%s","LoGainBlackout",(fRuns->GetRunsAsFileName()).Data()),
273 "Number Blackout events Lo Gain");
274 MHCamera disp23(geomcam, Form("%s%s","Excluded",(fRuns->GetRunsAsFileName()).Data()),
275 "Pixels previously excluded");
276 MHCamera disp24(geomcam, Form("%s%s","UnSuitable",(fRuns->GetRunsAsFileName()).Data()),
277 "Pixels not suited for further analysis");
278 MHCamera disp25(geomcam, Form("%s%s","UnReliable",(fRuns->GetRunsAsFileName()).Data()),
279 "Pixels not reliable for further analysis");
280 MHCamera disp26(geomcam, Form("%s%s","HiGainOscillating",(fRuns->GetRunsAsFileName()).Data()),
281 "Oscillating Pixels High Gain");
282 MHCamera disp27(geomcam, Form("%s%s","LoGainOscillating",(fRuns->GetRunsAsFileName()).Data()),
283 "Oscillating Pixels Low Gain");
284 MHCamera disp28(geomcam, Form("%s%s","AbsTimeMean",(fRuns->GetRunsAsFileName()).Data()),
285 "Abs. Arrival Times");
286 MHCamera disp29(geomcam, Form("%s%s","AbsTimeRms",(fRuns->GetRunsAsFileName()).Data()),
287 "RMS of Arrival Times");
288 MHCamera disp30(geomcam, Form("%s%s","MeanTime",(fRuns->GetRunsAsFileName()).Data()),
289 "Mean Rel. Arrival Times");
290 MHCamera disp31(geomcam, Form("%s%s","SigmaTime",(fRuns->GetRunsAsFileName()).Data()),
291 "Sigma Rel. Arrival Times");
292 MHCamera disp32(geomcam, Form("%s%s","TimeProb",(fRuns->GetRunsAsFileName()).Data()),
293 "Probability of Time Fit");
294 MHCamera disp33(geomcam, Form("%s%s","TimeNotFitValid",(fRuns->GetRunsAsFileName()).Data()),
295 "Pixels with not valid fit results");
296 MHCamera disp34(geomcam, Form("%s%s","TimeOscillating",(fRuns->GetRunsAsFileName()).Data()),
297 "Oscillating Pixels");
298
299 // Fitted charge means and sigmas
300 disp1.SetCamContent(fCalibrationCam, 0);
301 disp1.SetCamError( fCalibrationCam, 1);
302 disp2.SetCamContent(fCalibrationCam, 2);
303 disp2.SetCamError( fCalibrationCam, 3);
304
305 // Reduced Sigmas and reduced sigmas per charge
306 disp3.SetCamContent(fCalibrationCam, 5);
307 disp3.SetCamError( fCalibrationCam, 6);
308 disp4.SetCamContent(fCalibrationCam, 7);
309 disp4.SetCamError( fCalibrationCam, 8);
310
311 // F-Factor Method
312 disp5.SetCamContent(fCalibrationCam, 9);
313 disp5.SetCamError( fCalibrationCam, 10);
314 disp6.SetCamContent(fCalibrationCam, 11);
315 disp6.SetCamError( fCalibrationCam, 12);
316 disp7.SetCamContent(fCalibrationCam, 13);
317 disp7.SetCamError( fCalibrationCam, 14);
318
319 // Quantum Efficiencies
320 disp8.SetCamContent (fQECam, 0 );
321 disp8.SetCamError (fQECam, 1 );
322 disp9.SetCamContent (fQECam, 2 );
323 disp9.SetCamError (fQECam, 3 );
324 disp10.SetCamContent(fQECam, 4 );
325 disp10.SetCamError (fQECam, 5 );
326 disp11.SetCamContent(fQECam, 6 );
327 disp11.SetCamError (fQECam, 7 );
328
329 // Valid flags
330 disp12.SetCamContent(fQECam, 8 );
331 disp13.SetCamContent(fQECam, 9 );
332 disp14.SetCamContent(fQECam, 10);
333 disp15.SetCamContent(fQECam, 11);
334
335 // Conversion Hi-Lo
336 disp16.SetCamContent(fCalibrationCam, 25);
337 disp17.SetCamContent(fCalibrationCam, 16);
338 disp17.SetCamError (fCalibrationCam, 17);
339 disp18.SetCamContent(fCalibrationCam, 18);
340 disp18.SetCamError (fCalibrationCam, 19);
341
342 // Pickup and Blackout
343 disp19.SetCamContent(fCalibrationCam, 21);
344 disp20.SetCamContent(fCalibrationCam, 22);
345 disp21.SetCamContent(fCalibrationCam, 23);
346 disp22.SetCamContent(fCalibrationCam, 24);
347
348 // Pixels with defects
349 disp23.SetCamContent(fCalibrationCam, 20);
350 disp24.SetCamContent(fBadPixels, 1);
351 disp25.SetCamContent(fBadPixels, 3);
352
353 // Oscillations
354 disp26.SetCamContent(fBadPixels, 10);
355 disp27.SetCamContent(fBadPixels, 11);
356
357 // Arrival Times
358 disp28.SetCamContent(fCalibrationCam, 26);
359 disp28.SetCamError( fCalibrationCam, 27);
360 disp29.SetCamContent(fCalibrationCam, 27);
361
362 disp1.SetYTitle("Q [FADC counts]");
363 disp2.SetYTitle("\\sigma_{Q} [FADC counts]");
364
365 disp3.SetYTitle("\\sqrt{\\sigma^{2}_{Q} - RMS^{2}_{Ped}} [FADC Counts]");
366 disp4.SetYTitle("Red.Sigma/<Q> [1]");
367
368 disp5.SetYTitle("Nr. Phe's [1]");
369 disp6.SetYTitle("Conv.Factor [PhE/FADC counts]");
370 disp7.SetYTitle("Total F-Factor [1]");
371
372 disp8.SetYTitle("QE [1]");
373 disp9.SetYTitle("QE [1]");
374 disp10.SetYTitle("QE [1]");
375 disp11.SetYTitle("QE [1]");
376
377 disp12.SetYTitle("[1]");
378 disp13.SetYTitle("[1]");
379 disp14.SetYTitle("[1]");
380 disp15.SetYTitle("[1]");
381 disp16.SetYTitle("[1]");
382
383 disp17.SetYTitle("<Q>(High)/<Q>(Low) [1]");
384 disp18.SetYTitle("\\sigma_{Q}(High)/\\sigma_{Q}(Low) [1]");
385
386 disp19.SetYTitle("[1]");
387 disp20.SetYTitle("[1]");
388 disp21.SetYTitle("[1]");
389 disp22.SetYTitle("[1]");
390 disp23.SetYTitle("[1]");
391 disp24.SetYTitle("[1]");
392 disp25.SetYTitle("[1]");
393 disp26.SetYTitle("[1]");
394 disp27.SetYTitle("[1]");
395
396 disp28.SetYTitle("Mean Abs. Time [FADC slice]");
397 disp29.SetYTitle("RMS Abs. Time [FADC slices]");
398
399 if (fRelTimes)
400 {
401
402 disp30.SetCamContent(fRelTimeCam,0);
403 disp30.SetCamError( fRelTimeCam,1);
404 disp31.SetCamContent(fRelTimeCam,2);
405 disp31.SetCamError( fRelTimeCam,3);
406 disp32.SetCamContent(fRelTimeCam,4);
407 disp33.SetCamContent(fBadPixels,20);
408 disp34.SetCamContent(fBadPixels,21);
409
410 disp30.SetYTitle("Time Offset [FADC units]");
411 disp31.SetYTitle("Timing resolution [FADC units]");
412 disp32.SetYTitle("P_{Time} [1]");
413 disp33.SetYTitle("[1]");
414 disp34.SetYTitle("[1]");
415 }
416
417 if (fDisplayType == kDataCheckDisplay)
418 {
419 TCanvas &c1 = fDisplay->AddTab("Fit.Charge");
420 c1.Divide(3, 3);
421
422 disp1.CamDraw(c1, 1, 3, 2);
423 disp4.CamDraw(c1, 2, 3, 2);
424 disp28.CamDraw(c1, 3, 3, 2);
425
426 // F-Factor
427 TCanvas &c2 = fDisplay->AddTab("Phe's");
428 c2.Divide(3,4);
429
430 disp6.CamDraw(c2, 1, 3, 2, 1);
431 disp7.CamDraw(c2, 2, 3, 2, 1);
432 disp8.CamDraw(c2, 3, 3, 2, 1);
433
434 // QE's
435 TCanvas &c3 = fDisplay->AddTab("QE's");
436 c3.Divide(3,4);
437
438 disp8.CamDraw(c3, 1, 3, 2, 1);
439 disp9.CamDraw(c3, 2, 3, 2, 1);
440 disp10.CamDraw(c3, 3, 3, 2, 1);
441
442 // Defects
443 TCanvas &c4 = fDisplay->AddTab("Defect");
444 c4.Divide(2,2);
445
446 disp24.CamDraw(c4, 1, 2, 0);
447 disp25.CamDraw(c4, 2, 2, 0);
448
449 if (fRelTimes)
450 {
451 // Rel. Times
452 TCanvas &c5 = fDisplay->AddTab("Rel. Times");
453 c5.Divide(2,4);
454
455 disp30.CamDraw(c5, 1, 2, 2);
456 disp31.CamDraw(c5, 2, 2, 2);
457 }
458
459
460 return;
461 }
462
463 if (fDisplayType == kNormalDisplay)
464 {
465
466 // Charges
467 TCanvas &c11 = fDisplay->AddTab("Fit.Charge");
468 c11.Divide(2, 4);
469
470 disp1.CamDraw(c11, 1, 2, 5, 1);
471 disp2.CamDraw(c11, 2, 2, 5, 1);
472
473 // Reduced Sigmas
474 TCanvas &c12 = fDisplay->AddTab("Red.Sigma");
475 c12.Divide(2,4);
476
477 disp3.CamDraw(c12, 1, 2, 5, 1);
478 disp4.CamDraw(c12, 2, 2, 5, 1);
479
480 // F-Factor
481 TCanvas &c13 = fDisplay->AddTab("Phe's");
482 c13.Divide(3,4);
483
484 disp5.CamDraw(c13, 1, 3, 5, 1);
485 disp6.CamDraw(c13, 2, 3, 5, 1);
486 disp7.CamDraw(c13, 3, 3, 5, 1);
487
488 // QE's
489 TCanvas &c14 = fDisplay->AddTab("QE's");
490 c14.Divide(4,4);
491
492 disp8.CamDraw(c14, 1, 4, 5, 1);
493 disp9.CamDraw(c14, 2, 4, 5, 1);
494 disp10.CamDraw(c14, 3, 4, 5, 1);
495 disp11.CamDraw(c14, 4, 4, 5, 1);
496
497 // Defects
498 TCanvas &c15 = fDisplay->AddTab("Defect");
499 // c15.Divide(5,2);
500 c15.Divide(4,2);
501
502 /*
503 disp23.CamDraw(c15, 1, 5, 0);
504 disp24.CamDraw(c15, 2, 5, 0);
505 disp25.CamDraw(c15, 3, 5, 0);
506 disp26.CamDraw(c15, 4, 5, 0);
507 disp27.CamDraw(c15, 5, 5, 0);
508 */
509 disp24.CamDraw(c15, 1, 4, 0);
510 disp25.CamDraw(c15, 2, 4, 0);
511 disp26.CamDraw(c15, 3, 4, 0);
512 disp27.CamDraw(c15, 4, 4, 0);
513
514 // Abs. Times
515 TCanvas &c16 = fDisplay->AddTab("Abs. Times");
516 c16.Divide(2,3);
517
518 disp28.CamDraw(c16, 1, 2, 5);
519 disp29.CamDraw(c16, 2, 2, 5);
520
521 if (fRelTimes)
522 {
523 // Rel. Times
524 TCanvas &c17 = fDisplay->AddTab("Rel. Times");
525 c17.Divide(2,4);
526
527 disp30.CamDraw(c17, 1, 2, 5, 1);
528 disp31.CamDraw(c17, 2, 2, 5, 1);
529 }
530
531 return;
532 }
533
534 if (fDisplayType == kFullDisplay)
535 {
536
537 MHCalibrationCam *cam = (MHCalibrationCam*)plist.FindObject("MHCalibrationChargeCam");
538
539 for (Int_t sector=1;sector<cam->GetAverageSectors();sector++)
540 {
541 cam->GetAverageHiGainSector(sector).DrawClone("all");
542 cam->GetAverageLoGainSector(sector).DrawClone("all");
543 }
544
545 // Charges
546 TCanvas &c21 = fDisplay->AddTab("Fit.Charge");
547 c21.Divide(2, 4);
548
549 disp1.CamDraw(c21, 1, 2, 2, 1);
550 disp2.CamDraw(c21, 2, 2, 2, 1);
551
552 // Reduced Sigmas
553 TCanvas &c23 = fDisplay->AddTab("Red.Sigma");
554 c23.Divide(2,4);
555
556 disp3.CamDraw(c23, 1, 2, 2, 1);
557 disp4.CamDraw(c23, 2, 2, 2, 1);
558
559 // F-Factor
560 TCanvas &c24 = fDisplay->AddTab("Phe's");
561 c24.Divide(3,5);
562
563 disp5.CamDraw(c24, 1, 3, 2, 1, 1);
564 disp6.CamDraw(c24, 2, 3, 2, 1, 1);
565 disp7.CamDraw(c24, 3, 3, 2, 1, 1);
566
567 // QE's
568 TCanvas &c25 = fDisplay->AddTab("QE's");
569 c25.Divide(4,5);
570
571 disp8.CamDraw(c25, 1, 4, 2, 1, 1);
572 disp9.CamDraw(c25, 2, 4, 2, 1, 1);
573 disp10.CamDraw(c25, 3, 4, 2, 1, 1);
574 disp11.CamDraw(c25, 4, 4, 2, 1, 1);
575
576 // Validity
577 TCanvas &c26 = fDisplay->AddTab("Valid");
578 c26.Divide(4,2);
579
580 disp12.CamDraw(c26, 1, 4, 0);
581 disp13.CamDraw(c26, 2, 4, 0);
582 disp14.CamDraw(c26, 3, 4, 0);
583 disp15.CamDraw(c26, 4, 4, 0);
584
585 // Other info
586 TCanvas &c27 = fDisplay->AddTab("HiLoGain");
587 c27.Divide(3,3);
588
589 disp16.CamDraw(c27, 1, 3, 0);
590 disp17.CamDraw(c27, 2, 3, 1);
591 disp18.CamDraw(c27, 3, 3, 1);
592
593 // Pickup
594 TCanvas &c28 = fDisplay->AddTab("Pickup");
595 c28.Divide(4,2);
596
597 disp19.CamDraw(c28, 1, 4, 0);
598 disp20.CamDraw(c28, 2, 4, 0);
599 disp21.CamDraw(c28, 3, 4, 0);
600 disp22.CamDraw(c28, 4, 4, 0);
601
602 // Defects
603 TCanvas &c29 = fDisplay->AddTab("Defect");
604 // c29.Divide(5,2);
605 c29.Divide(4,2);
606
607 disp24.CamDraw(c29, 1, 4, 0);
608 disp25.CamDraw(c29, 2, 4, 0);
609 disp26.CamDraw(c29, 3, 4, 0);
610 disp27.CamDraw(c29, 4, 4, 0);
611
612 // Abs. Times
613 TCanvas &c30 = fDisplay->AddTab("Abs. Times");
614 c30.Divide(2,3);
615
616 disp28.CamDraw(c30, 1, 2, 2);
617 disp29.CamDraw(c30, 2, 2, 1);
618
619 if (fRelTimes)
620 {
621 // Rel. Times
622 TCanvas &c31 = fDisplay->AddTab("Rel. Times");
623 c31.Divide(3,5);
624
625 disp30.CamDraw(c31, 1, 3, 2, 1, 1);
626 disp31.CamDraw(c31, 2, 3, 2, 1, 1);
627 disp32.CamDraw(c31, 3, 3, 4, 1, 1);
628
629 // Time Defects
630 TCanvas &c32 = fDisplay->AddTab("Time Def.");
631 c32.Divide(2,2);
632
633 disp33.CamDraw(c32, 1, 2, 0);
634 disp34.CamDraw(c32, 2, 2, 0);
635
636 MHCalibrationCam *cam = (MHCalibrationCam*)plist.FindObject("MHCalibrationRelTimeCam");
637
638 for (Int_t sector=1;sector<cam->GetAverageSectors();sector++)
639 {
640 cam->GetAverageHiGainSector(sector).DrawClone("fourierevents");
641 cam->GetAverageLoGainSector(sector).DrawClone("fourierevents");
642 }
643
644 }
645
646 return;
647 }
648}
649
650
651
652// --------------------------------------------------------------------------
653//
654// Find the colour of the pulsing LED:
655// - If the run number is smaller than gkIFAEBoxInaugurationRun, take MCalibrationCam::kCT1
656// - Otherwise find the colour out of the run name
657// - If no colour is found, return kFALSE
658//
659Bool_t MJCalibration::FindColor()
660{
661
662 const UInt_t nruns = fRuns->GetNumRuns();
663
664 if (nruns == 0)
665 return kFALSE;
666
667 TArrayI arr = fRuns->GetRuns();
668
669 if (arr[nruns-1] < gkIFAEBoxInaugurationRun)
670 {
671 *fLog << "Found colour kCT1 in runs: " << fRuns->GetRunsAsString() << endl;
672 fColor = MCalibrationCam::kCT1;
673 return kTRUE;
674 }
675
676 TString filenames;
677 ((MDirIter*)fRuns)->Reset();
678
679 while (!(filenames=((MDirIter*)fRuns)->Next()).IsNull())
680 {
681
682 filenames.ToLower();
683
684 //
685 // Here starts the list of runs where the shifters did not put
686 // a colour, but which have been found out by other means
687 //
688 if (filenames.Contains("_27474_"))
689 if (fColor == MCalibrationCam::kNONE)
690 {
691 *fLog << "Sorry, run 27474 was taken with CLOSED LIDS. It should not be used! "
692 << "Selected runs were: " << filenames << endl;
693 fColor = MCalibrationCam::kNONE;
694 return kFALSE;
695 }
696 else if (fColor != MCalibrationCam::kNONE)
697 {
698 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
699 return kFALSE;
700 }
701
702 if (filenames.Contains("_26924_"))
703 if (fColor == MCalibrationCam::kNONE)
704 {
705 *fLog << "Found colour: kGREEN in " << filenames << endl;
706 fColor = MCalibrationCam::kGREEN;
707 }
708 else if (fColor != MCalibrationCam::kGREEN)
709 {
710 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
711 return kFALSE;
712 }
713
714
715 if (filenames.Contains("_26568_"))
716 if (fColor == MCalibrationCam::kNONE)
717 {
718 *fLog << "Found colour: kGREEN in " << filenames << endl;
719 fColor = MCalibrationCam::kGREEN;
720 }
721 else if (fColor != MCalibrationCam::kGREEN)
722 {
723 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
724 return kFALSE;
725 }
726
727 if (filenames.Contains("_26412_"))
728 if (fColor == MCalibrationCam::kNONE)
729 {
730 *fLog << "Found colour: kGREEN in " << filenames << endl;
731 fColor = MCalibrationCam::kGREEN;
732 }
733 else if (fColor != MCalibrationCam::kGREEN)
734 {
735 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
736 return kFALSE;
737 }
738
739
740 if (filenames.Contains("_26409_"))
741 if (fColor == MCalibrationCam::kNONE)
742 {
743 *fLog << "Found colour: kGREEN in " << filenames << endl;
744 fColor = MCalibrationCam::kGREEN;
745 }
746 else if (fColor != MCalibrationCam::kGREEN)
747 {
748 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
749 return kFALSE;
750 }
751
752 if (filenames.Contains("_26408_"))
753 if (fColor == MCalibrationCam::kNONE)
754 {
755 *fLog << "Found colour: kGREEN in " << filenames << endl;
756 fColor = MCalibrationCam::kGREEN;
757 }
758 else if (fColor != MCalibrationCam::kGREEN)
759 {
760 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
761 return kFALSE;
762 }
763
764
765 if (filenames.Contains("_26402_"))
766 if (fColor == MCalibrationCam::kNONE)
767 {
768 *fLog << "Found colour: kBLUE in " << filenames << endl;
769 fColor = MCalibrationCam::kBLUE;
770 }
771 else if (fColor != MCalibrationCam::kBLUE)
772 {
773 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
774 return kFALSE;
775 }
776
777 if (filenames.Contains("_20661_"))
778 if (fColor == MCalibrationCam::kNONE)
779 {
780 *fLog << "Found colour: kGREEN in " << filenames << endl;
781 fColor = MCalibrationCam::kGREEN;
782 }
783 else if (fColor != MCalibrationCam::kGREEN)
784 {
785 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
786 return kFALSE;
787 }
788
789 if (filenames.Contains("_20660_"))
790 if (fColor == MCalibrationCam::kNONE)
791 {
792 *fLog << "Found colour: kGREEN in " << filenames << endl;
793 fColor = MCalibrationCam::kGREEN;
794 }
795 else if (fColor != MCalibrationCam::kGREEN)
796 {
797 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
798 return kFALSE;
799 }
800
801 //
802 // Here start the runs where the shifter put
803 // the colour
804 //
805 if (filenames.Contains("green"))
806 if (fColor == MCalibrationCam::kNONE)
807 {
808 *fLog << "Found colour: kGREEN in " << filenames << endl;
809 fColor = MCalibrationCam::kGREEN;
810 }
811 else if (fColor != MCalibrationCam::kGREEN)
812 {
813 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
814 return kFALSE;
815 }
816
817 if (filenames.Contains("blue"))
818 if (fColor == MCalibrationCam::kNONE)
819 {
820 *fLog << "Found colour: kBLUE in " << filenames << endl;
821 fColor = MCalibrationCam::kBLUE;
822 }
823 else if (fColor != MCalibrationCam::kBLUE)
824 {
825 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
826 return kFALSE;
827 }
828
829 if (filenames.Contains("uv"))
830 if (fColor == MCalibrationCam::kNONE)
831 {
832 *fLog << "Found colour: kUV in " << filenames << endl;
833 fColor = MCalibrationCam::kUV;
834 }
835 else if (fColor != MCalibrationCam::kUV)
836 {
837 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
838 return kFALSE;
839 }
840
841 if (filenames.Contains("ct1"))
842 if (fColor == MCalibrationCam::kNONE)
843 {
844 *fLog << "Found colour: kCT1 in " << filenames << endl;
845 fColor = MCalibrationCam::kCT1;
846 }
847 else if (fColor != MCalibrationCam::kCT1)
848 {
849 *fLog << err << "Different colour found in " << filenames << "... abort" << endl;
850 return kFALSE;
851 }
852
853 }
854
855 if (fColor == MCalibrationCam::kNONE)
856 {
857 *fLog << "No colour found in filenames of runs: " << fRuns->GetRunsAsString()
858 << "... abort" << endl;
859 return kFALSE;
860 }
861
862 return kTRUE;
863}
864
865
866
867
868// --------------------------------------------------------------------------
869//
870// Retrieve the output file written by WriteResult()
871//
872const char* MJCalibration::GetOutputFile() const
873{
874
875 if (!fRuns)
876 return "";
877
878 return Form("%s/%s-F1.root", (const char*)fOutputPath, (const char*)fRuns->GetRunsAsFileName());
879}
880
881
882Bool_t MJCalibration::IsUseBlindPixel() const
883{
884 return TESTBIT(fDevices,kUseBlindPixel);
885}
886
887
888Bool_t MJCalibration::IsUsePINDiode() const
889{
890 return TESTBIT(fDevices,kUsePINDiode);
891}
892
893
894
895
896
897// --------------------------------------------------------------------------
898//
899// Call the ProcessFile(MPedestalCam)
900//
901Bool_t MJCalibration::Process(MPedestalCam &pedcam)
902{
903 if (!ReadCalibrationCam())
904 return ProcessFile(pedcam);
905
906 return kTRUE;
907}
908
909// --------------------------------------------------------------------------
910//
911// Execute the task list and the eventloop:
912//
913// - Check if there are fRuns, otherwise return
914// - Check the colour of the files in fRuns (FindColor()), otherwise return
915// - Check for consistency between run numbers and number of files
916// - Add fRuns to MReadMarsFile
917// - Put into MParList:
918// 1) MPedestalCam (pedcam)
919// 2) MCalibrationQECam (fQECam)
920// 3) MCalibrationChargeCam (fCalibrationCam)
921// 4) MCalibrationRelTimeCam (fRelTimeCam) (only if flag fRelTimes is chosen)
922// 5) MBadPixelsCam (fBadPixels)
923// 6) MCalibrationChargePINDiode
924// 7) MCalibrationChargeBlindPix
925// - Put into the MTaskList:
926// 1) MReadMarsFile
927// 2) MBadPixelsMerge
928// 3) MGeomApply
929// 4) MExtractor
930// 5) MExtractPINDiode
931// 6) MExtractBlindPixel
932// 7) MExtractTime (only if flag fRelTimes is chosen)
933// 8) MContinue(MFCosmics)
934// 9) MFillH("MHCalibrationChargePINDiode", "MExtractedSignalPINDiode")
935// 10) MFillH("MHCalibrationChargeBlindPix", "MExtractedSignalBlindPixel")
936// 11) MFillH("MHCalibrationChargeCam", "MExtractedSignalCam")
937// 12) MFillH("MHCalibrationChargeCam", "MExtractedSignalCam")
938// 13) MCalibrationChargeCalc
939// 14) MFillH("MHCalibrationRelTimeCam", "MArrivalTimeCam") (only if flag fRelTimes is chosen)
940// 15) MCalibrationRelTimeCalc
941// - Execute MEvtLoop
942// - DisplayResult()
943// - WriteResult()
944//
945Bool_t MJCalibration::ProcessFile(MPedestalCam &pedcam)
946{
947 if (!fRuns)
948 {
949 *fLog << err << "No Runs choosen... abort." << endl;
950 return kFALSE;
951 }
952
953 if (fRuns->GetNumRuns() != fRuns->GetNumEntries())
954 {
955 *fLog << err << "Number of files found doesn't match number of runs... abort."
956 << fRuns->GetNumRuns() << " vs. " << fRuns->GetNumEntries() << endl;
957 return kFALSE;
958 }
959
960 *fLog << inf;
961 fLog->Separator(GetDescriptor());
962
963 if (!FindColor())
964 return kFALSE;
965
966 *fLog << "Calculate MCalibrationCam from Runs " << fRuns->GetRunsAsString() << endl;
967 *fLog << endl;
968
969 // Setup Tasklist
970 MParList plist;
971 MTaskList tlist;
972 plist.AddToList(&tlist);
973
974 MReadMarsFile read("Events");
975 MRawFileRead rawread(NULL);
976
977 if (fDataCheck)
978 {
979 rawread.AddFiles(*fRuns);
980 tlist.AddToList(&rawread);
981 }
982 else
983 {
984 read.DisableAutoScheme();
985 static_cast<MRead&>(read).AddFiles(*fRuns);
986 tlist.AddToList(&read);
987 }
988
989 plist.AddToList(&pedcam);
990 plist.AddToList(&fBadPixels);
991 plist.AddToList(&fQECam);
992 plist.AddToList(&fCalibrationCam);
993 plist.AddToList(&fCalibrationBlindPix);
994 plist.AddToList(&fCalibrationPINDiode);
995 plist.AddToList(&fRelTimeCam);
996
997 MGeomApply apply;
998 // MBadPixelsMerge merge(&fBadPixels);
999 MExtractPINDiode pinext;
1000 MExtractBlindPixel blindext;
1001 MExtractSlidingWindow extract2;
1002 MExtractTimeSpline timespline;
1003 MCalibrationChargeCalc calcalc;
1004 calcalc.SetOutputPath(fOutputPath);
1005 calcalc.SetOutputFile(Form("%s-ChargeCalibStat.txt",(const char*)fRuns->GetRunsAsFileName()));
1006
1007 MCalibrationRelTimeCalc timecalc;
1008 timecalc.SetOutputPath(fOutputPath);
1009 timecalc.SetOutputFile(Form("%s-TimeCalibStat.txt",(const char*)fRuns->GetRunsAsFileName()));
1010
1011 //
1012 // As long as there are no DM's, have to colour by hand
1013 //
1014 calcalc.SetPulserColor(fColor);
1015
1016 MFillH fillpin("MHCalibrationChargePINDiode", "MExtractedSignalPINDiode");
1017 MFillH fillbnd("MHCalibrationChargeBlindPix", "MExtractedSignalBlindPixel");
1018 MFillH fillcam("MHCalibrationChargeCam", "MExtractedSignalCam");
1019 MFillH filltme("MHCalibrationRelTimeCam", "MArrivalTimeCam");
1020 fillpin.SetNameTab("PINDiode");
1021 fillbnd.SetNameTab("BlindPix");
1022 fillcam.SetNameTab("Charge");
1023 filltme.SetNameTab("RelTimes");
1024
1025 if (fDataCheck)
1026 {
1027 fillcam.SetDrawOption("datacheck");
1028 fillbnd.SetDrawOption("datacheck");
1029 fillpin.SetDrawOption("datacheck");
1030 filltme.SetDrawOption("datacheck");
1031 }
1032
1033 if (fDisplayType == kFullDisplay)
1034 {
1035 fillcam.SetDrawOption("all");
1036 filltme.SetDrawOption("all");
1037 }
1038
1039
1040 //
1041 // Apply a filter against cosmics
1042 // (will have to be needed in the future
1043 // when the calibration hardware-trigger is working)
1044 //
1045 MFCosmics cosmics;
1046 MContinue cont(&cosmics);
1047
1048 // tlist.AddToList(&merge);
1049 tlist.AddToList(&apply);
1050
1051 if (fExtractor)
1052 tlist.AddToList(fExtractor);
1053 else
1054 {
1055 *fLog << warn << GetDescriptor()
1056 << ": No extractor has been chosen, take default MExtractSlidingWindow " << endl;
1057 tlist.AddToList(&extract2);
1058 }
1059
1060
1061 tlist.AddToList(&pinext);
1062 tlist.AddToList(&blindext);
1063
1064 if (fRelTimes)
1065 {
1066 if (fTimeExtractor)
1067 tlist.AddToList(fTimeExtractor);
1068 else
1069 {
1070 *fLog << warn << GetDescriptor()
1071 << ": No extractor has been chosen, take default MTimeExtractSpline " << endl;
1072 tlist.AddToList(&timespline);
1073 }
1074 }
1075
1076 if (fColor == MCalibrationCam::kCT1)
1077 tlist.AddToList(&cont);
1078
1079 tlist.AddToList(&fillcam);
1080
1081 if (IsUsePINDiode())
1082 tlist.AddToList(&fillpin);
1083 if (IsUseBlindPixel())
1084 tlist.AddToList(&fillbnd);
1085
1086 tlist.AddToList(&calcalc);
1087
1088 if (fRelTimes)
1089 {
1090 tlist.AddToList(&filltme);
1091 tlist.AddToList(&timecalc);
1092 }
1093
1094
1095 // Create and setup the eventloop
1096 MEvtLoop evtloop(fName);
1097 evtloop.SetParList(&plist);
1098 evtloop.SetDisplay(fDisplay);
1099 evtloop.SetLogStream(fLog);
1100
1101 // Execute first analysis
1102 if (!evtloop.Eventloop())
1103 {
1104 *fLog << err << GetDescriptor() << ": Failed." << endl;
1105 return kFALSE;
1106 }
1107
1108 tlist.PrintStatistics();
1109
1110 DisplayResult(plist);
1111
1112 if (!WriteResult())
1113 return kFALSE;
1114
1115 *fLog << inf << GetDescriptor() << ": Done." << endl;
1116
1117 return kTRUE;
1118}
1119
1120// --------------------------------------------------------------------------
1121//
1122// Read the following containers from GetOutputFile()
1123// - MCalibrationChargeCam
1124// - MCalibrationQECam
1125// - MBadPixelsCam
1126//
1127Bool_t MJCalibration::ReadCalibrationCam()
1128{
1129
1130 const TString fname = GetOutputFile();
1131
1132 if (gSystem->AccessPathName(fname, kFileExists))
1133 {
1134 *fLog << err << "Input file " << fname << " doesn't exist." << endl;
1135 return kFALSE;
1136 }
1137
1138 *fLog << inf << "Reading from file: " << fname << endl;
1139
1140 TFile file(fname, "READ");
1141 if (fCalibrationCam.Read()<=0)
1142 {
1143 *fLog << err << "Unable to read MCalibrationChargeCam from " << fname << endl;
1144 return kFALSE;
1145 }
1146
1147 if (fQECam.Read()<=0)
1148 {
1149 *fLog << err << "Unable to read MCalibrationQECam from " << fname << endl;
1150 return kFALSE;
1151 }
1152
1153
1154 if (fRelTimes)
1155 if (fRelTimeCam.Read()<=0)
1156 {
1157 *fLog << err << "Unable to read MCalibrationRelTimeCam from " << fname << endl;
1158 return kFALSE;
1159 }
1160
1161 if (file.FindKey("MBadPixelsCam"))
1162 {
1163 MBadPixelsCam bad;
1164 if (bad.Read()<=0)
1165 {
1166 *fLog << err << "Unable to read MBadPixelsCam from " << fname << endl;
1167 return kFALSE;
1168 }
1169 fBadPixels.Merge(bad);
1170 }
1171
1172 if (fDisplay /*&& !fDisplay->GetCanvas("Pedestals")*/) // FIXME!
1173 fDisplay->Read();
1174
1175 return kTRUE;
1176}
1177
1178
1179// --------------------------------------------------------------------------
1180//
1181// Set the path for output files, written by WriteResult()
1182//
1183void MJCalibration::SetOutputPath(const char *path)
1184{
1185 fOutputPath = path;
1186 if (fOutputPath.EndsWith("/"))
1187 fOutputPath = fOutputPath(0, fOutputPath.Length()-1);
1188}
1189
1190// --------------------------------------------------------------------------
1191//
1192// Set the useage of the Blind Pixel device
1193//
1194void MJCalibration::SetUseBlindPixel(const Bool_t b)
1195{
1196 b ? SETBIT(fDevices,kUseBlindPixel) : CLRBIT(fDevices,kUseBlindPixel);
1197}
1198
1199// --------------------------------------------------------------------------
1200//
1201// Set the useage of the PIN Diode device
1202//
1203void MJCalibration::SetUsePINDiode(const Bool_t b)
1204{
1205 b ? SETBIT(fDevices,kUsePINDiode) : CLRBIT(fDevices,kUsePINDiode);
1206}
1207
1208// --------------------------------------------------------------------------
1209//
1210// Write the result into the output file GetOutputFile(), if fOutputPath exists.
1211//
1212// The following containers are written:
1213// - MStatusDisplay
1214// - MCalibrationChargeCam
1215// - MCalibrationChargeBlindPix
1216// - MCalibrationQECam
1217// - MBadPixelsCam
1218//
1219Bool_t MJCalibration::WriteResult()
1220{
1221 if (fOutputPath.IsNull())
1222 return kTRUE;
1223
1224 const TString oname(GetOutputFile());
1225
1226 *fLog << inf << "Writing to file: " << oname << endl;
1227
1228 TFile file(oname, "UPDATE");
1229
1230 if (fDisplay && fDisplay->Write()<=0)
1231 {
1232 *fLog << err << "Unable to write MStatusDisplay to " << oname << endl;
1233 return kFALSE;
1234 }
1235
1236 if (fCalibrationCam.Write()<=0)
1237 {
1238 *fLog << err << "Unable to write MCalibrationChargeCam to " << oname << endl;
1239 return kFALSE;
1240 }
1241
1242 if (fCalibrationBlindPix.Write()<=0)
1243 {
1244 *fLog << err << "Unable to write MCalibrationChargeBlindPix to " << oname << endl;
1245 return kFALSE;
1246 }
1247
1248 if (fCalibrationPINDiode.Write()<=0)
1249 {
1250 *fLog << err << "Unable to write MCalibrationChargePINDiode to " << oname << endl;
1251 return kFALSE;
1252 }
1253
1254 if (fQECam.Write()<=0)
1255 {
1256 *fLog << err << "Unable to write MCalibrationQECam to " << oname << endl;
1257 return kFALSE;
1258 }
1259
1260 if (fRelTimes)
1261 if (fRelTimeCam.Write()<=0)
1262 {
1263 *fLog << err << "Unable to write MCalibrationQECam to " << oname << endl;
1264 return kFALSE;
1265 }
1266
1267 if (fBadPixels.Write()<=0)
1268 {
1269 *fLog << err << "Unable to write MBadPixelsCam to " << oname << endl;
1270 return kFALSE;
1271 }
1272
1273 return kTRUE;
1274
1275}
1276