1\section{Signal Reconstruction Algorithms \label{sec:algorithms}}
2
3{\it Missing coding:
4\begin{itemize}
5\item Real fit to the expected pulse shape \ldots Hendrik, Wolfgang ???
6\end{itemize}
7}
8
9\subsection{Implementation of Signal Extractors in MARS}
10
11All signal extractor classes are stored in the MARS-directory {\textit{\bf msignal/}}.
12There, the base classes {\textit{\bf MExtractor}}, {\textit{\bf MExtractTime}}, {\textit{\bf MExtractTimeAndCharge}} and
13all individual extractors can be found. Figure~\ref{fig:extractorclasses} gives a sketch of the
14inheritances of each class and what each class calculates.
15
16\begin{figure}[htp]
17\includegraphics[width=0.99\linewidth]{ExtractorClasses.eps}
18\caption{Sketch of the inheritances of three examplary MARS signal extractor classes:
19MExtractFixedWindow, MExtractTimeFastSpline and MExtractTimeAndChargeDigitalFilter}
20\label{fig:extractorclasses}
21\end{figure}
22
23The following base classes for the extractor tasks are used:
24\begin{description}
25\item[MExtractor:\xspace] This class provides the basic data members equal for all extractors which are:
26 \begin{enumerate}
27 \item Global extraction ranges, parameterized by the variables
28 {\textit{\bf fHiGainFirst, fHiGainLast, fLoGainFirst, fLoGainLast}} and the function {\textit{\bf SetRange()}}.
29 The ranges always {\textit{\bf include}} the edge slices.
30 \item An internal variable {\textit{\bf fHiLoLast}} regulating the overlap of the desired high-gain
31 extraction range into the low-gain array.
32 \item The maximum possible FADC value, before the slice is declared as saturated, parameterized
33 by the variable {\textit{\bf fSaturationLimit}} (default:\,254).
34 \item The typical delay between high-gain and low-gain slices, expressed in FADC slices and parameterized
35 by the variable {\textit{\bf fOffsetLoGain}} (default:\,1.51)
36 \item Pointers to the used storage containers {\textit{\bf MRawEvtData, MRawRunHeader, MPedestalCam}}
37 and~{\textit{\bf MExtractedSignalCam}}, parameterized by the variables
38 {\textit{\bf fRawEvt, fRunHeader, fPedestals}} and~{\textit{\bf fSignals}}.
39 \item Names of the used storage containers to be searched for in the parameter list, parameterized
40 by the variables {\textit{\bf fNamePedestalCam}} and~{\textit{\bf fNameSignalCam}} (default: ``MPedestalCam''
41 and~''MExtractedSignalCam'').
42 \item The equivalent number of FADC samples, used for the calculation of the pedestal RMS and then the
43 number of photo-electrons with the F-Factor method (see eq.~\ref{eq:rmssubtraction} and
44 section~\ref{sec:photo-electrons}). This number is parameterized by the variables
45 {\textit{\bf fNumHiGainSamples}} and~{\textit{\bf fNumLoGainSamples}}.
46 \end{enumerate}
47
48 {\textit {\bf MExtractor}} is able to loop over all events, if the {\textit{\bf Process()}}-function is not overwritten.
49 It uses the following (virtual) functions, to be overwritten by the derived extractor class:
50
51 \begin{enumerate}
52 \item void {\textit {\bf FindSignalHiGain}}(Byte\_t* firstused, Byte\_t* logain, Float\_t\& sum, Byte\_t\& sat) const
53 \item void {\textit {\bf FindSignalLoGain}}(Byte\_t* firstused, Float\_t\& sum, Byte\_t\& sat) const
54 \end{enumerate}
55
56 where the pointers ``firstused'' point to the first used FADC slice declared by the extraction ranges,
57 the pointer ``logain'' points to the beginning of the ``low-gain'' FADC slices array (to be used for
58 pulses reaching into the low-gain array) and the variables ``sum'' and ``sat'' get filled with the
59 extracted signal and the number of saturating FADC slices, respectively.
60 \par
61 The pedestals get subtracted automatically {\textit {\bf after}} execution of these two functions.
62
63\item[MExtractTime:\xspace] This class provides - additionally to those already declared in {\textit{\bf MExtractor}} -
64 the basic data members equal for all time extractors which are:
65 \begin{enumerate}
66 \item Pointer to the used storage container {\textit{\bf MArrivalTimeCam}}
67 parameterized by the variables
68 {\textit{\bf fArrTime}}.
69 \item The name of the used ``MArrivalTimeCam''-container to be searched for in the parameter list,
70 parameterized by the variables {\textit{\bf fNameTimeCam}} (default: ``MArrivalTimeCam'' ).
71 \end{enumerate}
72
73 {\textit {\bf MExtractTime}} is able to loop over all events, if the {\textit{\bf Process()}}-function is not
74 overwritten.
75 It uses the following (virtual) functions, to be overwritten by the derived extractor class:
76
77 \begin{enumerate}
78 \item void {\textit {\bf FindTimeHiGain}}(Byte\_t* firstused, Float\_t\& time, Float\_t\& dtime, Byte\_t\& sat, const MPedestlPix \&ped) const
79 \item void {\textit {\bf FindTimeLoGain}}(Byte\_t* firstused, Float\_t\& time, Float\_t\& dtime, Byte\_t\& sat, const MPedestalPix \&ped) const
80 \end{enumerate}
81
82 where the pointers ``firstused'' point to the first used FADC slice declared by the extraction ranges,
83 and the variables ``time'', ``dtime'' and ``sat'' get filled with the
84 extracted arrival time, its error and the number of saturating FADC slices, respectively.
85 \par
86 The pedestals can be used for the arrival time extraction via the reference ``ped''.
87
88\item[MExtractTimeAndCharge:\xspace] This class provides - additionally to those already declared in
89 {\textit{\bf MExtractor}} and {\textit{\bf MExtractTime}} -
90 the basic data members equal for all time and charge extractors which are:
91 \begin{enumerate}
92 \item The actual extraction window sizes, parameterized by the variables
93 {\textit{\bf fWindowSizeHiGain}} and {\textit{\bf fWindowSizeLoGain}}.
94 \item The shift of the low-gain extraction range start w.r.t. to the found high-gain arrival
95 time, parameterized by the variable {\textit{\bf fLoGainStartShift}} (default: -2.8)
96 \end{enumerate}
97
98 {\textit {\bf MExtractTimeAndCharge}} is able to loop over all events, if the {\textit{\bf Process()}}-function is not
99 overwritten.
100 It uses the following (virtual) functions, to be overwritten by the derived extractor class:
101
102 \begin{enumerate}
103 \item void {\textit {\bf FindTimeAndChargeHiGain}}(Byte\_t* firstused, Byte\_t* logain, Float\_t\& sum, Float\_t\& dsum,
104 Float\_t\& time, Float\_t\& dtime, Byte\_t\& sat,
105 const MPedestlPix \&ped, const Bool\_t abflag) const
106 \item void {\textit {\bf FindTimeAndChargeLoGain}}(Byte\_t* firstused, Float\_t\& sum, Float\_t\& dsum,
107 Float\_t\& time, Float\_t\& dtime, Byte\_t\& sat,
108 const MPedestalPix \&ped, const Bool\_t abflag) const
109 \end{enumerate}
110
111 where the pointers ``firstused'' point to the first used FADC slice declared by the extraction ranges,
112 the pointer ``logain'' point to the beginning of the low-gain FADC slices array (to be used for
113 pulses reaching into the ``low-gain'' array),
114 the variables ``sum'', ``dsum'' get filled with the
115 extracted signal and its error. The variables ``time'', ``dtime'' and ``sat'' get filled with the
116 extracted arrival time, its error and the number of saturating FADC slices, respectively.
117 \par
118 The pedestals can be used for the extraction via the reference ``ped'', also the AB-flag is given
119 for AB-clock noise correction.
120\end{description}
121
122
123\subsection{Pure Signal Extractors}
124
125The pure signal extractors have in common that they reconstruct only the
126charge, but not the arrival time. All treated extractors here derive from the MARS-base
127class {\textit{\bf MExtractor}} which provides the following facilities:
128
129\begin{itemize}
130\item The global extraction limits can be set from outside
131\item FADC saturation is kept track of
132\end{itemize}
133
134The following adjustable parameters have to be set from outside:
135\begin{description}
136\item[Global extraction limits:\xspace] Limits in between which the extractor is allowed
137to extract the signal, for high gain and low gain, respectively.
138\end{description}
139
140As the pulses jitter by about one FADC slice,
141not every pulse lies exactly within the optimal limits, especially if one takes small
142extraction windows.
143Moreover, the readout position with respect to the trigger position has changed a couple
144of times during last year, therefore a very careful adjustment of the extraction limits
145is mandatory before using these extractors.
146
147\subsubsection{Fixed Window}
148
149This extractor is implemented in the MARS-class {\textit{\bf MExtractFixedWindow}}.
150It simply adds the FADC slice contents in the assigned ranges.
151As it does not correct for the clock-noise, only an even number of samples is allowed.
152Figure~\ref{fig:fixedwindowsketch} gives a sketch of the used extraction ranges for this
153paper and two typical calibration pulses.
154
155\begin{figure}[htp]
156 \includegraphics[width=0.49\linewidth]{MExtractFixedWindow_5Led_UV.eps}
157 \includegraphics[width=0.49\linewidth]{MExtractFixedWindow_23Led_Blue.eps}
158\caption[Sketch extraction ranges MExtractFixedWindow]{%
159Sketch of the extraction ranges for the extractor {\textit{\bf MExtractFixedWindow}}
160for two typical calibration pulses (pedestals have been subtracted) and a typical inner pixel.
161The pulse would be shifted half a slice to the right for an outer pixel. }
162\label{fig:fixedwindowsketch}
163\end{figure}
164
165
166\subsubsection{Fixed Window with Integrated Cubic Spline}
167
168This extractor is implemented in the MARS-class {\textit{\bf MExtractFixedWindowSpline}}. It
169uses a cubic spline algorithm, adapted from \cite{NUMREC} and integrates the
170spline interpolated FADC slice values from a fixed extraction range. The edge slices are counted as half.
171As it does not correct for the clock-noise, only an odd number of samples is allowed.
172Figure~\ref{fig:fixedwindowsplinesketch} gives a sketch of the used extraction ranges for this
173paper and two typical calibration pulses.
174
175\begin{figure}[htp]
176 \includegraphics[width=0.49\linewidth]{MExtractFixedWindowSpline_5Led_UV.eps}
177 \includegraphics[width=0.49\linewidth]{MExtractFixedWindowSpline_23Led_Blue.eps}
178\caption[Sketch extraction ranges MExtractFixedWindowSpline]{%
179Sketch of the extraction ranges for the extractor {\textit{\bf MExtractFixedWindowSpline}}
180for two typical calibration pulses (pedestals have been subtracted) and a typical inner pixel.
181The pulse would be shifted half a slice to the right for an outer pixel. }
182\label{fig:fixedwindowsplinesketch}
183\end{figure}
184
185\subsubsection{Fixed Window with Global Peak Search}
186
187This extractor is implemented in the MARS-class {\textit{\bf MExtractFixedWindowPeakSearch}}.
188The basic idea of this extractor is to correct for coherent movements in arrival time for all pixels,
189as e.g. caused by the trigger jitter.
190In a first loop, it fixes a reference point defined as the highest sum of
191consecutive non-saturating FADC slices in a (smaller) peak-search window.
192\par
193In a second loop over the pixels,
194it adds the FADC contents starting from a pre-defined offset from the obtained peak-search window
195over an extraction window of a pre-defined window size.
196It loops twice over all pixels in every event, because it has to find the reference point, first.
197As it does not correct for the clock-noise, only an even number of samples is allowed.
198For a high intensity calibration run causing high-gain saturation in the whole camera, this
199extractor apparently fails since only dead pixels are taken into account in the peak search
200 which cannot produce a saturated signal.
201For this special case, we modified {\textit{\bf MExtractFixedWindowPeakSearch}}
202such to define the peak search window as the one starting from the mean position of the first saturating slice.
203\par
204The following adjustable parameters have to be set from outside:
205\begin{description}
206\item[Peak Search Window:\xspace] Defines the ``sliding window'' size within which the peaking sum is
207searched for (default: 4 slices)
208\item[Offset from Window:\xspace] Defines the offset of the start of the extraction window w.r.t. the
209starting point of the obtained peak search window (default: 1 slice)
210\item[Low-Gain Peak shift:\xspace] Defines the shift in the low-gain with respect to the peak found
211in the high-gain (default: 1 slice)
212\end{description}
213
214Figure~\ref{fig:fixedwindowpeaksearchsketch} gives a sketch of the possible peak-search and extraction
215window positions in two typical calibration pulses.
216
217\begin{figure}[htp]
218 \includegraphics[width=0.49\linewidth]{MExtractFixedWindowPeakSearch_5Led_UV.eps}
219 \includegraphics[width=0.49\linewidth]{MExtractFixedWindowPeakSearch_23Led_Blue.eps}
220\caption[Sketch extraction ranges MExtractFixedWindowPeakSearch]{%
221Sketch of the extraction ranges for the extractor {\textit{\bf MExtractFixedWindowPeakSearch}}
222for two typical calibration pulses (pedestals have been subtracted) and a typical inner pixel.
223The pulse would be shifted half a slice to the right for an outer pixel. }
224\label{fig:fixedwindowpeaksearchsketch}
225\end{figure}
226
227\subsection{Combined Extractors}
228
229The combined extractors have in common that they reconstruct the arrival time and
230the charge at the same time and for the same pulse.
231All treated combined extractors here derive from the MARS-base
232class {\textit{\bf MExtractTimeAndCharge}} which itself derives from MExtractor and MExtractTime.
233It provides the following facilities:
234
235\begin{itemize}
236\item Only one loop over all pixels is performed.
237\item The individual FADC slice values get the clock-noise-corrected pedestals immediately subtracted.
238\item The low-gain extraction range is adapted dynamically, based on the computed arrival time
239 from the high-gain samples.
240\item Extracted times from the low-gain samples get corrected for the intrinsic time delay of the low-gain
241 pulse.
242\item The global extraction limits can be set from outside.
243\item FADC saturation is kept track of.
244\end{itemize}
245
246The following adjustable parameters have to be set from outside, additionally to those declared in the
247base classes MExtractor and MExtractTime:
248
249\begin{description}
250\item[Global extraction limits:\xspace] Limits in between which the extractor is allowed
251to search. They are fixed by the extractor for the high-gain, but re-adjusted for
252every event in the low-gain, depending on the arrival time found in the low-gain.
253However, the dynamically adjusted window is not allowed to pass beyond the global
254limits.
255\item[Low-gain start shift:\xspace] Global shift between the computed high-gain arrival
256time and the start of the low-gain extraction limit (corrected for the intrinsic time offset).
257This variable tells where the extractor is allowed to start searching for the low-gain signal
258if the high-gain arrival time is known. It avoids that the extractor gets confused by possible high-gain
259signals leaking into the ``low-gain'' region (default: -2.8).
260\end{description}
261
262\subsubsection{Sliding Window with Amplitude-Weighted Time}
263
264This extractor is implemented in the MARS-class {\textit{\bf MExtractTimeAndChargeSlidingWindow}}.
265It extracts the signal from a sliding window of an adjustable size, for high-gain and low-gain
266individually (default: 6 and 6). The signal is the one which maximizes the summed
267(clock-noise and pedestal-corrected) consecutive FADC slice contents.
268\par
269The amplitude-weighted arrival time is calculated from the window with
270the highest FADC slice contents integral using the following formula:
271
272\begin{equation}
273 t = \frac{\sum_{i=i_0}^{i_0+ws} s_i \cdot i}{\sum_{i=i_0}^{i_0t+ws} i}
274\end{equation}
275where $i$ denotes the FADC slice index, starting from $i_0$
276window and running over a window of size $ws$. $s_i$ the clock-noise and
277pedestal-corrected FADC slice contents at slice position $i$.
278\par
279The following adjustable parameters have to be set from outside:
280\begin{description}
281\item[Window sizes:\xspace] Independently for high-gain and low-gain (default: 6,6)
282\end{description}
283
284\begin{figure}[htp]
285 \includegraphics[width=0.49\linewidth]{MExtractTimeAndChargeSlidingWindow_5Led_UV.eps}
286 \includegraphics[width=0.49\linewidth]{MExtractTimeAndChargeSlidingWindow_23Led_Blue.eps}
287\caption[Sketch calculated arrival times MExtractTimeAndChargeSlidingWindow]{%
288Sketch of the calculated arrival times for the extractor {\textit{\bf MExtractTimeAndChargeSlidingWindow}}
289for two typical calibration pulses (pedestals have been subtracted) and a typical inner pixel.
290The extraction window sizes modify the position of the (amplitude-weighted) mean FADC-slices slightly.
291The pulse would be shifted half a slice to the right for an outer pixel. }
292\label{fig:slidingwindowsketch}
293\end{figure}
294
295\subsubsection{Cubic Spline with Sliding Window or Amplitude Extraction}
296
297This extractor is implemented in the MARS-class {\textit{\bf MExtractTimeAndChargeSpline}}.
298It interpolates the FADC contents using a cubic spline algorithm, adapted from \cite{NUMREC}.
299In a second step, it searches for the position of the spline maximum. From then on, two
300possibilities are offered:
301
302\begin{description}
303\item[Extraction Type Amplitude:\xspace] The amplitude of the spline maximum is taken as charge signal
304and the (precisee) position of the maximum is returned as arrival time. This type is faster, since it
305performs not spline intergraion.
306\item[Extraction Type Integral:\xspace] The integrated spline between maximum position minus
307rise time (default: 1.5 slices) and maximum position plus fall time (default: 4.5 slices)
308is taken as charge signal and the position of the half maximum left from the position of the maximum
309is returned as arrival time (default).
310The low-gain signal stretches the rise and fall time by a stretch factor (default: 1.5). This type
311is slower, but yields more precise results (see section~\ref{sec:performance}) .
312The charge integration resolution is set to 0.1 FADC slices.
313\end{description}
314
315The following adjustable parameters have to be set from outside:
316
317\begin{description}
318\item[Charge Extraction Type:\xspace] The amplitude of the spline maximum can be chosen while the position
319of the maximum is returned as arrival time. This type is fast. \\
320Otherwise, the integrated spline between maximum position minus rise time (default: 1.5 slices)
321and maximum position plus fall time (default: 4.5 slices) is taken as signal and the position of the
322half maximum is returned as arrival time (default).
323The low-gain signal stretches the rise and fall time by a stretch factor (default: 1.5). This type
324is slower, but more precise. The charge integration resolution is 0.1 FADC slices.
325\item[Rise Time and Fall Time:\xspace] Can be adjusted for the integration charge extraction type.
326\item[Resolution:\xspace] Defined as the maximum allowed difference between the calculated half maximum value and
327the computed spline value at the arrival time position. Can be adjusted for the half-maximum time extraction
328type.
329\item[Low Gain Stretch:\xspace] Can be adjusted to account for the larger rise and fall times in the
330low-gain as compared to the high gain pulses (default: 1.5)
331\end{description}
332
333\begin{figure}[htp]
334 \includegraphics[width=0.49\linewidth]{MExtractTimeAndChargeSpline_5Led_UV.eps}
335 \includegraphics[width=0.49\linewidth]{MExtractTimeAndChargeSpline_23Led_Blue.eps}
336\caption[Sketch calculated arrival times MExtractTimeAndChargeSpline]{%
337Sketch of the calculated arrival times for the extractor {\textit{\bf MExtractTimeAndChargeSpline}}
338for two typical calibration pulses (pedestals have been subtracted) and a typical inner pixel.
339The extraction window sizes modify the position of the (amplitude-weighted) mean FADC-slices slightly.
340The pulse would be shifted half a slice to the right for an outer pixel. }
341\label{fig:splinesketch}
342\end{figure}
343
344\subsubsection{Digital Filter}
345
346This extractor is implemented in the MARS-class {\textit{\bf MExtractTimeAndChargeDigitalFilter}}.
347
348
349The goal of the digital filtering method \cite{OF94,OF77} is to optimally reconstruct the amplitude and time origin of a signal with a known signal shape
350from discrete measurements of the signal. Thereby, the noise contribution to the amplitude reconstruction is minimized.
351
352For the digital filtering method, three assumptions have to be made:
353
354\begin{itemize}
355\item{The normalized signal shape has to be independent of the signal amplitude.}
356\item{The noise properties have to be independent of the signal amplitude.}
357\item{The noise auto-correlation matrix does not change its form significantly with time.}
358\end{itemize}
359
360\par
361\ldots {\textit{\bf IS THIS TRUE FOR MAGIC???? }} \ldots
362\par
363
364Let $g(t)$ be the normalized signal shape, $E$ the signal amplitude and $\tau$ the time shift
365of the physical signal from the predicted signal shape. Then the time dependence of the signal, $y(t)$, is given by:
366
367\begin{equation}
368y(t)=E \cdot g(t-\tau) + b(t) \ ,
369\end{equation}
370
371where $b(t)$ is the time-dependent noise contribution. For small time shifts $\tau$ (usually smaller than
372one FADC slice width),
373the time dependence can be linearized by the use of a Taylor expansion:
374
375\begin{equation} \label{shape_taylor_approx}
376y(t)=E \cdot g(t) - E\tau \cdot \dot{g}(t) + b(t) \ ,
377\end{equation}
378
379where $\dot{g}(t)$ is the time derivative of the signal shape. Discrete
380measurements $y_i$ of the signal at times $t_i \ (i=1,...,n)$ have the form:
381
382\begin{equation}
383y_i=E \cdot g_i- E\tau \cdot \dot{g}_i +b_i \ .
384\end{equation}
385
386The correlation of the noise contributions at times $t_i$ and $t_j$ can be expressed in the
387noise autocorrelation matrix $\boldsymbol{B}$:
388
389\begin{equation}
390B_{ij} = \langle b_i b_j \rangle - \langle b_i \rangle \langle b_j
391\rangle \ .
392\label{eq:autocorr}
393\end{equation}
394%\equiv \langle b_i b_j \rangle with $\langle b_i \rangle = 0$.
395
396The signal amplitude $E$, and the product of amplitude and time shift $E \tau$, can be estimated from the given set of
397measurements $\boldsymbol{y} = (y_1, ... ,y_n)$ by minimizing the excess noise contribution with respect to the known noise
398auto-correlation:
399
400\begin{eqnarray}
401\chi^2(E, E\tau) &=& \sum_{i,j}(y_i-E g_i-E\tau \dot{g}_i) (\boldsymbol{B}^{-1})_{ij} (y_j - E g_j-E\tau \dot{g}_j) \\
402&=& (\boldsymbol{y} - E
403\boldsymbol{g} - E\tau \dot{\boldsymbol{g}})^T \boldsymbol{B}^{-1} (\boldsymbol{y} - E \boldsymbol{g}- E\tau \dot{\boldsymbol{g}}) \ ,
404\end{eqnarray}
405
406where the last expression is matricial.
407$\chi^2$ is a continuous function of $\tau$ and will have to be discretized itself for a
408desired resolution.
409$\chi^2$ is in principle independent from the noise auto-correlation matrix if always the correct noise level is calculated there.
410In our case however, we decided to use one same matrix $\boldsymbol{B}$ for all levels of night-sky background since increases
411in the noise level lead only to a multiplicative factor for all matrix elements and thus do not affect the position of the minimum of $\chi^2$.
412The minimum of $\chi^2$ is obtained for:
413
414\begin{equation}
415\frac{\partial \chi^2(E, E\tau)}{\partial E} = 0 \qquad \text{and} \qquad \frac{\partial \chi^2(E, E\tau)}{\partial(E\tau)} = 0 \ .
416\end{equation}
417
418
419Taking into account that $\boldsymbol{B}$ is a symmetric matrix, this leads to the following
420two equations for the estimated amplitude $\overline{E}$ and the estimation for the product of amplitude
421and time offset $\overline{E\tau}$:
422
423\begin{eqnarray}
4240&=&-\boldsymbol{g}^T\boldsymbol{B}^{-1}\boldsymbol{y}
425 +\boldsymbol{g}^T\boldsymbol{B}^{-1}\boldsymbol{g}\overline{E}
426 +\boldsymbol{g}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}\overline{E\tau}
427\\
4280&=&-\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\boldsymbol{y}
429 +\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\boldsymbol{g}\overline{E}
430 +\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}\overline{E\tau} \ .
431\end{eqnarray}
432
433Solving these equations one gets the following solutions:
434
435\begin{equation}
436\overline{E}(\tau) = \boldsymbol{w}_{\text{amp}}^T (\tau)\boldsymbol{y} \quad \mathrm{with} \quad
437 \boldsymbol{w}_{\text{amp}}
438 = \frac{ (\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}) \boldsymbol{B}^{-1} \boldsymbol{g} -(\boldsymbol{g}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}) \boldsymbol{B}^{-1} \dot{\boldsymbol{g}}}
439 {(\boldsymbol{g}^T \boldsymbol{B}^{-1} \boldsymbol{g})(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}) -(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\boldsymbol{g})^2 } \ ,
440\end{equation}
441
442\begin{equation}
443\overline{E\tau}(\tau)= \boldsymbol{w}_{\text{time}}^T(\tau) \boldsymbol{y} \quad
444 \mathrm{with} \quad \boldsymbol{w}_{\text{time}}
445 = \frac{ ({\boldsymbol{g}}^T\boldsymbol{B}^{-1}{\boldsymbol{g}}) \boldsymbol{B}^{-1} \dot{\boldsymbol{g}} -(\boldsymbol{g}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}) \boldsymbol{B}^{-1} {\boldsymbol{g}}}
446 {(\boldsymbol{g}^T \boldsymbol{B}^{-1} \boldsymbol{g})(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}) -(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\boldsymbol{g})^2 } \ .
447\end{equation}
448
449Thus $\overline{E}$ and $\overline{E\tau}$ are given by a weighted sum of the discrete measurements $y_i$
450with the digital filtering weights for the amplitude, $w_{\text{amp}}(\tau)$, and time shift, $w_{\text{time}}(\tau)$
451where the time dependency gets discretized once again leading to a set of weights samples which themselves depend on the
452discretized time $\tau$.
453\par
454Note the remaining time dependency of the two weights samples which follow from the dependency of $\boldsymbol{g}$ and
455$\dot{\boldsymbol{g}}$ on the position of the pulse with respect to the FADC bin positions.
456\par
457Because of the truncation of the Taylor series in equation (\ref{shape_taylor_approx}) the above results are
458only valid for vanishing time offsets $\tau$. For non-zero time offsets one has to iterate the problem using
459the time shifted signal shape $g(t-\tau)$.
460
461The covariance matrix $\boldsymbol{V}$ of $\overline{E}$ and $\overline{E\tau}$ is given by:
462
463\begin{equation}
464\left(\boldsymbol{V}^{-1}\right)_{i,j}
465 =\frac{1}{2}\left(\frac{\partial^2 \chi^2(E, E\tau)}{\partial \alpha_i \partial \alpha_j} \right) \quad
466 \text{with} \quad \alpha_i,\alpha_j \in \{E, E\tau\} \ .
467\end{equation}
468
469The expected contribution of the noise to the estimated amplitude, $\sigma_E$, is:
470
471\begin{equation}
472\sigma_E^2=\boldsymbol{V}_{E,E}
473 =\frac{\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}}
474 {(\boldsymbol{g}^T \boldsymbol{B}^{-1} \boldsymbol{g})(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}) -(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\boldsymbol{g})^2} \ .
475\label{eq:of_noise}
476\end{equation}
477
478The expected contribution of the noise to the estimated timing, $\sigma_{\tau}$, is:
479
480\begin{equation}
481E^2 \cdot \sigma_{\tau}^2=\boldsymbol{V}_{E\tau,E\tau}
482 =\frac{{\boldsymbol{g}}^T\boldsymbol{B}^{-1}{\boldsymbol{g}}}
483 {(\boldsymbol{g}^T \boldsymbol{B}^{-1} \boldsymbol{g})(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\dot{\boldsymbol{g}}) -(\dot{\boldsymbol{g}}^T\boldsymbol{B}^{-1}\boldsymbol{g})^2} \ .
484\label{eq:of_noise_time}
485\end{equation}
486
487For the MAGIC signals, as implemented in the MC simulations, a pedestal RMS of a single FADC slice of 4 FADC counts introduces an error in the
488reconstructed signal and time of:
489
490\begin{equation}
491\sigma_E \approx 8.3 \ \mathrm{FADC\ counts} \qquad \sigma_{\tau} \approx \frac{6.5\ \Delta T_{\mathrm{FADC}}}{(E\ /\ \mathrm{FADC\ counts})} \ ,
492\label{eq:of_noise_calc}
493\end{equation}
494
495\par
496\ldots {\textit{\bf CALCULATE THESE NUMBERS FOR 6 SLICES! }} \ldots
497\par
498
499where $\Delta T_{\mathrm{FADC}} = 3.33$ ns is the sampling interval of the MAGIC FADCs.
500
501
502For an IACT there are two types of background noise. On the one hand, there is the constantly present
503electronics noise,
504on the other hand, the light of the night sky introduces a sizeable background noise to the measurement of
505Cherenkov photons from air showers.
506
507The electronics noise is largely white, uncorrelated in time. The noise from the night sky background photons
508is the superposition of the
509detector response to single photo electrons following a Poisson distribution in time.
510Figure \ref{fig:noise_autocorr_allpixels} shows the noise
511autocorrelation matrix for an open camera. The large noise autocorrelation in time of the current FADC
512system is due to the pulse shaping with a shaping constant of 6 ns.
513
514In general, the amplitude and time weights, $\boldsymbol{w}_{\text{amp}}$ and $\boldsymbol{w}_{\text{time}}$, depend on the pulse shape, the
515derivative of the pulse shape and the noise autocorrelation. In the high gain samples the correlated night sky background noise dominates over
516the white electronics noise. Thus different noise levels just cause the noise autocorrelation matrix $\boldsymbol{B}$ to change by a same factor,
517which cancels out in the weights calculation. Thus in the high gain the weights are to a very good approximation independent of the night
518sky background noise level.
519
520Contrary to that in the low gain samples ... .
521\ldots
522\ldots {\textit{\bf SITUATION FOR LOW-GAIN SAMPLES! }} \ldots
523\par
524
525
526
527\begin{figure}[h!]
528\begin{center}
529\includegraphics[totalheight=7cm]{noise_autocorr_AB_36038_TDAS.eps}
530\end{center}
531\caption[Noise autocorrelation one pixel.]{Noise autocorrelation
532matrix $\boldsymbol{B}$ for open camera including the noise due to night sky background fluctuations
533for one single pixel (obtained from 1000 events).}
534\label{fig:noise_autocorr_1pix}
535\end{figure}
536
537\begin{figure}[htp]
538\begin{center}
539\includegraphics[totalheight=7cm]{noise_38995_smallNSB_all396.eps}
540\includegraphics[totalheight=7cm]{noise_39258_largeNSB_all396.eps}
541\includegraphics[totalheight=7cm]{noise_small_over_large.eps}
542\end{center}
543\caption[Noise autocorrelation average all pixels.]{Noise autocorrelation
544matrix $\boldsymbol{B}$ for open camera and averaged over all pixels. The top figure shows $\boldsymbol{B}$
545obtained with camera pointing off the galactic plane (and low night sky background fluctuations).
546The central figure shows $\boldsymbol{B}$ with the camera pointing into the galactic plane
547(high night sky background) and the
548bottom plot shows the ratio between both. One can see that the entries of $\boldsymbol{B}$ do not
549simply scale with the amount of night sky background.}
550\label{fig:noise_autocorr_allpixels}
551\end{figure}
552
553Using the average reconstructed pulpo pulse shape, as shown in figure \ref{fig:pulpo_shape_low}, and the
554reconstructed noise autocorrelation matrix from a pedestal run
555
556\par
557\ldots {\textit{\bf WHICH RUN (RUN NUMBER, WHICH NSB?, WHICH PIXELS ??}} \ldots
558\par
559
560with random triggers, the digital filter
561weights are computed. Figures \ref{fig:w_time_MC_input_TDAS} and \ref{fig:w_amp_MC_input_TDAS} show the
562parameterization of the amplitude and timing weights for the MC pulse shape as a function of the ...
563
564\par
565\ldots {\textit{\bf MISSING END OF SENTENCE }} \ldots
566\par
567
568\begin{figure}[h!]
569\begin{center}
570\includegraphics[totalheight=7cm]{w_time_MC_input_TDAS.eps}
571\end{center}
572\caption[Time weights.]{Time weights $w_{\mathrm{time}}(t_0) \ldots w_{\mathrm{time}}(t_5)$ for a window size of 6 FADC slices for the pulse shape
573used in the MC simulations. The first weight $w_{\mathrm{time}}(t_0)$ is plotted as a function of the relative time $t_{\text{rel}}$ the trigger and the
574FADC clock in the range $[-0.5,0.5[ \ T_{\text{ADC}}$, the second weight in the range $[0.5,1.5[ \ T_{\text{ADC}}$ and so on. A binning resolution
575of $0.1\,T_{\text{ADC}}$ has been chosen.} \label{fig:w_time_MC_input_TDAS}
576\end{figure}
577
578\begin{figure}[h!]
579\begin{center}
580\includegraphics[totalheight=7cm]{w_amp_MC_input_TDAS.eps}
581\end{center}
582\caption[Amplitude weights.]{Amplitude weights $w_{\mathrm{amp}}(t_0) \ldots w_{\mathrm{amp}}(t_5)$ for a window size of 6 FADC slices for the
583pulse shape used in the MC simulations. The first weight $w_{\mathrm{amp}}(t_0)$ is plotted as a function of the relative time $t_{\text{rel}}$
584the trigger and the FADC clock in the range $[-0.5,0.5[ \ T_{\text{ADC}}$, the second weight in the range $[0.5,1.5[ \ T_{\text{ADC}}$ and so on.
585A binning resolution of $0.1\, T_{\text{ADC}}$ has been chosen.} \label{fig:w_amp_MC_input_TDAS}
586\end{figure}
587
588In the current implementation a two step procedure is applied to reconstruct the signal. The weight functions $w_{\mathrm{amp}}(t)$
589and $w_{\mathrm{time}}(t)$ are computed numerically with a resolution of $1/10$ of an FADC slice.
590In the first step the quantities $e_{i_0}$ and $e\tau_{i_0}$ are computed using a window of $n$ slices:
591
592\begin{equation}
593e_{i_0}=\sum_{i=i_0}^{i_0+n-1} w_{\mathrm{amp}}(t_i)y(t_{i+i_0}) \qquad (e\tau)_{i_0}=\sum_{i=i_0}^{i_0+n-1} w_{\mathrm{time}}(t_i)y(t_{i+i_0})
594\end{equation}
595
596for all possible signal start slices $i_0$. Let $i_0^*$ be the signal start slice with the largest $e_{i_0}$.
597Then in a second step the timing offset $\tau$ is calculated:
598
599\begin{equation}
600\tau=\frac{(e\tau)_{i_0^*}}{e_{i_0^*}}
601\label{eq:offsettau}
602\end{equation}
603
604and the weights iterated:
605
606\begin{equation}
607E=\sum_{i=i_0^*}^{i_0^*+n-1} w_{\mathrm{amp}}(t_i - \tau)y(t_{i+i_0^*}) \qquad
608 E \theta=\sum_{i=i_0^*}^{i_0^*+n-1} w_{\mathrm{time}}(t_i - \tau)y(t_{i+i_0^*}) \ .
609\end{equation}
610
611The reconstructed signal is then taken to be $E$ and the reconstructed arrival time $t_{\text{arrival}}$ is
612
613\begin{equation}
614t_{\text{arrival}} = i_0^* + \tau + \theta \ .
615\end{equation}
616
617
618
619% This does not apply for MAGIC as the LONs are giving always a correlated noise (in addition to the artificial shaping)
620
621%In the case of an uncorrelated noise with zero mean the noise autocorrelation matrix is:
622
623%\begin{equation}
624%\boldsymbol{B}_{ij}= \langle b_i b_j \rangle \delta_{ij} = \sigma^2(b_i) \ ,
625%\end{equation}
626
627%where $\sigma(b_i)$ is the standard deviation of the noise of the discrete measurements. Equation (\ref{of_noise}) than becomes:
628
629
630%\begin{equation}
631%\frac{\sigma^2(b_i)}{\sigma_E^2} = \sum_{i=1}^{n}{g_i^2} - \frac{\sum_{i=1}^{n}{g_i \dot{g}_i}}{\sum_{i=1}^{n}{\dot{g}_i^2}} \ .
632%\end{equation}
633
634
635\begin{figure}[h!]
636\begin{center}
637\includegraphics[totalheight=7cm]{amp_sliding.eps}
638\includegraphics[totalheight=7cm]{time_sliding.eps}
639\end{center}
640\caption[Digital filter weights applied.]{Digital filter weights applied to the recorded FADC time slices of
641one calibration pulse. The left plot shows the result of the applied amplitude weights
642$e(t_0)=\sum_{i=0}^{i=n-1} w_{\mathrm{amp}}(t_0+i \cdot T_{\text{ADC}})y(t_0+i \cdot T_{\text{ADC}})$ and
643the right plot shows the result of the applied timing weights
644$e\tau(t_0)=\sum_{i=0}^{i=n-1} w_{\mathrm{time}}(t_0+i \cdot T_{\text{ADC}})y(t_0+i \cdot T_{\text{ADC}})$ .}
645\label{fig:amp_sliding}
646\end{figure}
647
648
649\ldots
650\textit {\bf FIGURE~\ref{fig:shape_fit_TDAS} shows what???}
651\ldots
652
653Figure \ref{fig:shape_fit_TDAS} shows the FADC slices of a single MC event together with the result of a full
654fit of the input MC pulse shape to the simulated FADC samples together with the result of the numerical fit
655using the digital filter.
656
657
658\begin{figure}[h!]
659\begin{center}
660\includegraphics[totalheight=7cm]{shape_fit_TDAS.eps}
661\end{center}
662\caption[Shape fit.]{Full fit to the MC pulse shape with the MC input shape and a numerical fit using the
663digital filter.} \label{fig:shape_fit_TDAS}
664\end{figure}
665
666
667\ldots {\it Hendrik ... }
668
669The following free adjustable parameters have to be set from outside:
670
671\begin{description}
672\item[Weights File:\xspace] An ascii-file containing the weights, the binning resolution and
673the window size. Currently, the following weight files have been created:
674\begin{itemize}
675\item "cosmics\_weights.dat'' with a window size of 6 FADC slices
676\item "cosmics\_weights4.dat'' with a window size of 4 FADC slices
677\item "calibration\_weights\_blue.dat'' with a window size of 6 FADC slices
678\item "calibration\_weights4\_blue.dat'' with a window size of 4 FADC slices
679\item "calibration\_weights\_UV.dat'' with a window size of 6 FADC slices and in the low-gain the
680calibration weigths obtained from blue pulses\footnote{UV-pulses saturating the high-gain are not yet
681available.}.
682\item "calibration\_weights4\_UV.dat'' with a window size of 4 FADC slices and in the low-gain the
683calibration weigths obtained from blue pulses\footnote{UV-pulses saturating the high-gain are not yet
684available.}.
685\item "cosmics\_weights\_logaintest.dat'' with a window size of 6 FADC slices and swapped high-gain and low-gain
686weights. This file is only used for stability tests.
687\item "cosmics\_weights4\_logaintest.dat'' with a window size of 4 FADC slices and swapped high-gain and low-gain
688weights. This file is only used for stability tests.
689\item "calibration\_weights\_UV\_logaintest.dat'' with a window size of 6 FADC slices and swapped high-gain and low-gain
690weights. This file is only used for stability tests.
691\item "calibration\_weights4\_UV\_logaintest.dat'' with a window size of 4 FADC slices and swapped high-gain and low-gain
692weights. This file is only used for stability tests.
693\item "calibration\_weights\_blue\_logaintest.dat'' with a window size of 6 FADC slices and swapped high-gain and low-gain
694weights. This file is only used for stability tests.
695\item "calibration\_weights4\_blue\_logaintest.dat'' with a window size of 4 FADC slices and swapped high-gain and low-gain
696weights. This file is only used for stability tests.
697\end{itemize}
698\end{description}
699
700\begin{figure}[htp]
701 \includegraphics[width=0.49\linewidth]{MExtractTimeAndChargeDigitalFilter_5Led_UV.eps}
702 \includegraphics[width=0.49\linewidth]{MExtractTimeAndChargeDigitalFilter_23Led_Blue.eps}
703\caption[Sketch calculated arrival times MExtractTimeAndChargeDigitalFilter]{%
704Sketch of the calculated arrival times for the extractor {\textit{MExtractTimeAndChargeDigitalFilter}}
705for two typical calibration pulses (pedestals have been subtracted) and a typical inner pixel.
706The extraction window sizes modify the position of the (amplitude-weighted) mean FADC-slices slightly.
707The pulse would be shifted half a slice to the right for an outer pixels. }
708\label{fig:dfsketch}
709\end{figure}
710
711\subsubsection{Digital Filter with Global Peak Search}
712
713This extractor is implemented in the MARS-class {\textit{\bf MExtractTimeAndChargeDigitalFilterPeakSearch}}.
714
715The idea of this extractor is to combine {\textit{\bf MExtractFixedWindowPeakSearch}} and
716{\textit{\bf MExtractTimeAndChargeDigitalFilter}} in order to correct for coherent movements in arrival time
717for all pixels and still use the digital filter fit capabilities.
718 \par
719
720In a first loop, it fixes a reference point defined as the highest sum of
721consecutive non-saturating FADC slices in a (smaller) peak-search window.
722\par
723In a second loop over the pixels,
724it uses the digital filter algorithm within a reduced extraction window.
725It loops twice over all pixels in every event, because it has to find the reference point, first.
726
727As in the case of {\textit{\bf MExtractFixedWindowPeakSearch}}, for a high intensity calibration run
728causing high-gain saturation in the whole camera, this
729extractor apparently fails since only dead pixels
730are taken into account in the peak search which cannot produce a saturated signal.
731
732\par
733For this special case, the extractor then defines the peak search window
734as the one starting from the mean position of the first saturating slice.
735\par
736The following adjustable parameters have to be set from outside, additionally to the ones to be
737set in {\textit{\bf MExtractTimeAndChargeDigitalFilter}}:
738\begin{description}
739\item[Peak Search Window:\xspace] Defines the ``sliding window'' size within which the peaking sum is
740searched for (default: 2 slices)
741\item[Offset left from Peak:\xspace] Defines the left offset of the start of the extraction window w.r.t. the
742starting point of the obtained peak search window (default: 3 slices)
743\item[Offset right from Peak:\xspace] Defines the right offset of the of the extraction window w.r.t. the
744starting point of the obtained peak search window (default: 3 slices)
745\item[Limit for high gain failure events:\xspace] Defines the limit of the number of events which failed
746to be in the high-gain window before the run is rejected.
747\item[Limit for low gain failure events:\xspace] Defines the limit of the number of events which failed
748to be in the low-gain window before the run is rejected.
749\end{description}
750
751In principle, the ``offsets'' can be chosen very small, because both showers and calibration pulses spread
752over a very small time interval, typically less than one FADC slice. However, the MAGIC DAQ produces
753artificial jumps of two FADC slices from time to time\footnote{in 5\% of the events per pixel in December 2004},
754so the 3 slices are made in order not to reject these pixels already with the extractor.
755
756\subsubsection{Real Fit to the Expected Pulse Shape }
757
758This extractor is not yet implemented as MARS-class...
759\par
760It fits the pulse shape to a Landau convoluted with a Gaussian using the following
761parameters:...
762
763\ldots {\it Hendrik, Wolfgang ... }
764
765\begin{figure}[h!]
766\begin{center}
767\includegraphics[totalheight=7cm]{probability_fit_0ns.eps}
768\end{center}
769\caption[Fit Probability.]{Probability of the fit with the input signal shape to the simulated FADC samples
770including electronics and NSB noise.} \label{fig:w_amp_MC_input_TDAS.eps}
771\end{figure}
772
773
774
775\subsection{Used Extractors for this Analysis}
776
777We tested in this TDAS the following parameterized extractors:
778
779\begin{description}
780\item[MExtractFixedWindow]: with the following intialization, if {\textit{maxbin}} defines the
781 mean position of the high-gain FADC slice which carries the pulse maximum \footnote{The function
782{\textit{MExtractor::SetRange(higain first, higain last, logain first, logain last)}} sets the extraction
783range with the high gain start bin {\textit{higain first}} to (including) the last bin {\textit{higain last}}.
784Analoguously for the low gain extraction range. Note that in MARS, the low-gain FADC samples start with
785the index 0 again, thus {\textit{maxbin+0.5}} means in reality {\textit{maxbin+15+0.5}}. }
786:
787\begin{enumerate}
788\item SetRange({\textit{maxbin}}-1,{\textit{maxbin}}+2,{\textit{maxbin}}+0.5,{\textit{maxbin}}+3.5);
789\item SetRange({\textit{maxbin}}-1,{\textit{maxbin}}+2,{\textit{maxbin}}-0.5,{\textit{maxbin}}+4.5);
790\item SetRange({\textit{maxbin}}-2,{\textit{maxbin}}+3,{\textit{maxbin}}-0.5,{\textit{maxbin}}+4.5);
791\item SetRange({\textit{maxbin}}-2,{\textit{maxbin}}+5,{\textit{maxbin}}-0.5,{\textit{maxbin}}+6.5);
792\item SetRange({\textit{maxbin}}-3,{\textit{maxbin}}+10,{\textit{maxbin}}-1.5,{\textit{maxbin}}+7.5);
793\suspend{enumerate}
794\item[MExtractFixedWindowSpline]: with the following initialization, if {\textit{maxbin}} defines the
795 mean position of the high-gain FADC slice carrying the pulse maximum \footnote{The function
796{\textit{MExtractor::SetRange(higain first, higain last, logain first, logain last)}} sets the extraction
797range with the high gain start bin {\textit{higain first}} to (including) the last bin {\textit{higain last}}.
798Analoguously for the low gain extraction range. Note that in MARS, the low-gain FADC samples start with
799the index 0 again, thus {\textit{maxbin+0.5}} means in reality {\textit{maxbin+15+0.5}}.}:
800\resume{enumerate}
801\item SetRange({\textit{maxbin}}-1,{\textit{maxbin}}+3,{\textit{maxbin}}+0.5,{\textit{maxbin}}+4.5);
802\item SetRange({\textit{maxbin}}-1,{\textit{maxbin}}+3,{\textit{maxbin}}-0.5,{\textit{maxbin}}+5.5);
803\item SetRange({\textit{maxbin}}-2,{\textit{maxbin}}+4,{\textit{maxbin}}-0.5,{\textit{maxbin}}+5.5);
804\item SetRange({\textit{maxbin}}-2,{\textit{maxbin}}+6,{\textit{maxbin}}-0.5,{\textit{maxbin}}+7.5);
805\item SetRange({\textit{maxbin}}-3,{\textit{maxbin}}+11,{\textit{maxbin}}-1.5,{\textit{maxbin}}+8.5);
806\suspend{enumerate}
807\item[MExtractFixedWindowPeakSearch]: with the following initialization: \\
808SetRange(0,18,2,14); and:
809\resume{enumerate}
810\item SetWindows(2,2,2); SetOffsetFromWindow(0);
811\item SetWindows(4,4,2); SetOffsetFromWindow(1);
812\item SetWindows(4,6,4); SetOffsetFromWindow(0);
813\item SetWindows(6,6,4); SetOffsetFromWindow(1);
814\item SetWindows(8,8,4); SetOffsetFromWindow(1);
815\item SetWindows(14,10,4); SetOffsetFromWindow(2);
816\suspend{enumerate}
817\item[MExtractTimeAndChargeSlidingWindow]: with the following initialization: \\
818\resume{enumerate}
819\item SetWindowSize(2,2); SetRange(5,11,7,11);
820\item SetWindowSize(4,4); SetRange(5,13,6,12);
821\item SetWindowSize(4,6); SetRange(5,13,5,13);
822\item SetWindowSize(6,6); SetRange(4,14,5,13);
823\item SetWindowSize(8,8); SetRange(4,16,4,14);
824\item SetWindowSize(14,10); SetRange(5,10,7,11);
825\suspend{enumerate}
826\item[MExtractTimeAndChargeSpline]: with the following initialization:
827\resume{enumerate}
828\item SetChargeType(MExtractTimeAndChargeSpline::kAmplitude); \\
829SetRange(5,10,7,10);
830\suspend{enumerate}
831SetChargeType(MExtractTimeAndChargeSpline::kIntegral); \\
832and:
833\resume{enumerate}
834\item SetRiseTime(0.5); SetFallTime(0.5); SetRange(5,10,7,11);
835\item SetRiseTime(0.5); SetFallTime(1.5); SetRange(5,11,7,12);
836\item SetRiseTime(1.0); SetFallTime(3.0); SetRange(4,12,5,13);
837\item SetRiseTime(1.5); SetFallTime(4.5); SetRange(4,14,3,13);
838\suspend{enumerate}
839\item[MExtractTimeAndChargeDigitalFilter]: with the following initialization:
840\resume{enumerate}
841\item SetWeightsFile(``cosmics\_weights.dat''); SetRange(4,14,5,13);
842\item SetWeightsFile(``cosmics\_weights4.dat''); SetRange(5,13,6,12);
843\item SetWeightsFile(``calibration\_weights\_UV.dat'');
844\item SetWeightsFile(``calibration\_weights4\_UV.dat'');
845\item SetWeightsFile(``calibration\_weights\_blue.dat'');
846\item SetWeightsFile(``calibration\_weights4\_blue.dat'');
847\item SetWeightsFile(``cosmic\_weights\_logain6.dat'');
848\item SetWeightsFile(``cosmic\_weights\_logain4.dat'');
849\item SetWeightsFile(``calibration\_weights\_UV\_logaintest.dat'');
850\item SetWeightsFile(``calibration\_weights4\_UV\_logaintest.dat'');
851\item SetWeightsFile(``calibration\_weights\_blue\_logaintest.dat'');
852\item SetWeightsFile(``calibration\_weights4\_blue\_logaintest.dat'');
853\suspend{enumerate}
854\item[MExtractTimeAndChargeDigitalFilterPeakSearch]: with the following initialization:
855\resume{enumerate}
856\item SetWeightsFile(``calibration\_weights4\_UV.dat''); SetRange(0,20,0,14); \\
857 SetOffsetLeftFromPeak(3); SetOffsetRightFromPeak(3); \\
858 SetPeakSearchWindowSize(2);
859\suspend{enumerate}
860\item[``Real Fit'']: (not yet implemented, one try)
861\resume{enumerate}
862\item Real Fit
863\end{enumerate}
864\end{description}
865
866Note that the extractors \#34 through \#39 are used only to test the stability of the extraction against
867changes in the pulse-shape.
868
869References: \cite{OF77,OF94}.
870
871
872%%% Local Variables:
873%%% mode: latex
874%%% TeX-master: "MAGIC_signal_reco"
875%%% End:
Note: See TracBrowser for help on using the repository browser.