3In this section, we describe the tests performed using light pulses of different colour,
4pulse shapes and intensities with the MAGIC LED Calibration Pulser Box \cite{hardware-manual}.
5\par
6The LED pulser system is able to provide fast light pulses of 3--4\,ns FWHM
7with intensities ranging from 3--4 to more than 500 photo-electrons in one inner photo-multiplier of the
8camera. These pulses can be produced in three colours {\textit {\bf green, blue}} and
9{\textit{\bf UV}}.
10
11\begin{table}[htp]
12\centering
13\begin{tabular}{|c|c|c|c|c|c|c|}
14\hline
15\hline
16\multicolumn{7}{|c|}{The possible pulsed light colours} \\
17\hline
18\hline
19Colour & Wavelength & Spectral Width & Min. Nr. & Max. Nr. & Secondary & FWHM \\
20 & [nm] & [nm] & Phe's & Phe's & Pulses & Pulse [ns]\\
21\hline
22Green & 520 & 40 & 6 & 120 & yes & 3--4 \\
23\hline
24Blue & 460 & 30 & 6 & 500 & yes & 3--4 \\
25\hline
26UV & 375 & 12 & 3 & 50 & no & 2--3 \\
27\hline
28\hline
29\end{tabular}
30\caption{The pulser colours available from the calibration system}
31\label{tab:pulsercolours}
32\end{table}
33
34Table~\ref{tab:pulsercolours} lists the available colours and intensities and
35figures~\ref{fig:pulseexample1leduv} and~\ref{fig:pulseexample23ledblue} show exemplary pulses
36as registered by the FADCs.
37Whereas the UV-pulse is very stable, the green and blue pulses show sometimes smaller secondary
38pulses after about 10--40\,ns from the main pulse.
39One can see that the very stable UV-pulses are unfortunately only available in such intensities as to
40not saturate the high-gain readout channel. However, the brightest combination of light pulses easily
41saturates all channels in the camera, but does not reach a saturation of the low-gain readout.
42\par
43Our tests can be classified into three subsections:
44
45\begin{enumerate}
46\item Un-calibrated pixels and events: These tests measure the percentage of failures of the extractor
47resulting either in a pixel declared as un-calibrated or in an event which produces a signal ouside
48of the expected Gaussian distribution.
49\item Number of photo-electrons: These tests measure the reconstructed numbers of photo-electrons, their
50spread over the camera and the ratio of the obtained mean values for outer and inner pixels, respectively.
51\item Linearity tests: These tests measure the linearity of the extractor with respect to pulses of
52different intensity and colour.
53\item Time resolution: These tests show the time resolution and stability obtained with different
54intensities and colours.
55\end{enumerate}
56
57\begin{figure}[htp]
58\centering
59\includegraphics[width=0.48\linewidth]{1LedUV_Pulse_Inner.eps}
60\includegraphics[width=0.48\linewidth]{1LedUV_Pulse_Outer.eps}
61\caption{Example of a calibration pulse from the lowest available intensity (1\,Led UV).
62The left plot shows the signal obtained in an inner pixel, the right one the signal in an outer pixel.
63Note that the pulse height fluctuates much more than suggested from these pictures. Especially, a
64zero-pulse is also possible.}
65\label{fig:pulseexample1leduv}
66\end{figure}
67
68\begin{figure}[htp]
69\centering
70\includegraphics[width=0.48\linewidth]{23LedsBlue_Pulse_Inner.eps}
71\includegraphics[width=0.48\linewidth]{23LedsBlue_Pulse_Outer.eps}
72\caption{Example of a calibration pulse from the highest available mono-chromatic intensity (23\,Leds Blue).
73The left plot shows the signal obtained in an inner pixel, the right one the signal in an outer pixel.
74One the left side of both plots, the (saturated) high-gain channel is visible,
75on the right side from FADC slice 18 on,
76the delayed low-gain
77pulse appears. Note that in the left plot, there is a secondary pulses visible in the tail of the
78high-gain pulse. }
79\label{fig:pulseexample23ledblue}
80\end{figure}
81
82We used data taken on the 7$^{th}$ of June, 2004 with different pulser LED combinations, each taken with
8316384 events. 19 different calibration configurations have been tested.
84The corresponding MAGIC data run numbers range from nr. 31741 to 31772. These data was taken
85before the latest camera repair access which resulted in a replacement of about 2\% of the pixels known to be
86mal-functionning at that time.
87There is thus a lower limit to the number of un-calibrated pixels of about 1.5--2\% of known
88mal-functionning photo-multipliers.
89\par
90Although we had looked at and tested all colour and extractor combinations resulting from these data,
91we refrain ourselves to show here only exemplary behaviour and results of extractors.
92All plots, including those which are not displayed in this TDAS, can be retrieved from the following
93locations:
94
95\begin{verbatim}
96http://www.magic.ifae.es/~markus/pheplots/
97http://www.magic.ifae.es/~markus/timeplots/
98\end{verbatim}
99
100%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
101
102\subsection{Un-Calibrated Pixels and Events}
103
104The MAGIC calibration software incorporates a series of checks to sort out mal-functionning pixels.
105Except for the software bug searching criteria, the following exclusion criteria can apply:
106
107\begin{enumerate}
108\item The reconstructed mean signal is less than 2.5 times the extractor resolution $R$ from zero.
109(2.5 Pedestal RMS in the case of the simple fixed window extractors, see section~\ref{sec:pedestals}).
110This criterium essentially cuts out
111dead pixels.
112\item The reconstructed mean signal error is smaller than its value. This criterium cuts out
113signal distributions which fluctuate so much that their RMS is bigger than its mean value. This
114criterium cuts out ``ringing'' pixels or mal-functionning extractors.
115\item The reconstructed mean number of photo-electrons lies 4.5 sigma outside
116the distribution of photo-electrons obtained with the inner or outer pixels in the camera, respectively.
117This criterium cuts out pixels channels with apparently deviating (hardware) behaviour compared to
118the rest of the camera readout\footnote{This criteria is not applied any more in the standard analysis,
119although here, we kept using it}.
120\item All pixels with reconstructed negative mean signal or with a
121mean numbers of photo-electrons smaller than one. Pixels with a negative pedestal RMS subtracted
122sigma occur, especially when stars are focussed onto that pixel during the pedestal taking (resulting
123in a large pedestal RMS), but have moved to another pixel during the calibration run. In this case, the
124number of photo-electrons would result artificially negative. If these
125channels do not show any other deviating behaviour, their number of photo-electrons gets replaced by the
126mean number of photo-electrons in the camera, and the channel is further calibrated as normal.
127\end{enumerate}
128
129Moreover, the number of events are counted which have been reconstructed outside a 5 sigma region
130from the mean signal. These events are called ``outliers''. Figure~\ref{fig:outlier} shows a typical
131outlier obtained with the digital filter applied to a low-gain signal and figure~\ref{fig:unsuited:all}
132shows the average number of all excluded pixels and outliers obtained from all 19 calibration configurations.
133One can already see that the largest window sizes yield a high number of un-calibrated pixels, mostly
134due to the missing ability to recognize the low-intensity pulses (see later). One can also see that
135the amplitude extracting spline yields a higher number of outliers than the rest of the extractors.
136The global champion in lowest number of un-calibrated pixels results to be
137{\textit{\bf MExtractTimeAndChargeDigitalFilter}} with the correct calibration weights over 4 FADC slices
138(extractor \#31). The one with the lowest number of outliers is
139{\textit{\bf MExtractFixedWindowPeakSearch}} with an extraction range of 2 slices (extractor \#11).
140
141\begin{figure}[htp]
142\centering
143\includegraphics[width=0.95\linewidth]{Outlier.eps}
144\caption{Example of an event classified as ``un-calibrated''. The histogram has been obtained
145using the digital filter (extractor \#32) applied to a high-intensity blue pulse (run 31772).
146The event marked as ``outlier'' clearly has been mis-reconstructed. It lies outside the 5 sigma
147region from the fitted mean.}
148\label{fig:outlier}
149\end{figure}
150
151\begin{figure}[htp]
152\centering
153\includegraphics[height=0.75\textheight]{UnsuitVsExtractor-all.eps}
154\caption{Uncalibrated pixels and pixels outside of the Gaussian distribution averaged over all available
155calibration runs.}
156\label{fig:unsuited:all}
157\end{figure}
158
159The following figures~\ref{fig:unsuited:5ledsuv},~\ref{fig:unsuited:1leduv},~\ref{fig:unsuited:2ledsgreen}
160and~\ref{fig:unsuited:23ledsblue} show the resulting numbers of un-calibrated pixels and events for
161different colours and intensities. Because there is a strong anti-correlation between the number of
162excluded channels and the number of outliers per event, we have chosen to show these numbers together.
163
164\par
165
166\begin{figure}[htp]
167\centering
168\includegraphics[height=0.95\textheight]{UnsuitVsExtractor-5LedsUV-Colour-13.eps}
169\caption{Uncalibrated pixels and pixels outside of the Gaussian distribution for a typical calibration
170pulse of UV-light which does not saturate the high-gain readout.}
171\label{fig:unsuited:5ledsuv}
172\end{figure}
173
174\begin{figure}[htp]
175\centering
176\includegraphics[height=0.95\textheight]{UnsuitVsExtractor-1LedUV-Colour-04.eps}
177\caption{Uncalibrated pixels and pixels outside of the Gaussian distribution for a very low
178intensity pulse.}
179\label{fig:unsuited:1leduv}
180\end{figure}
181
182\begin{figure}[htp]
183\centering
184\includegraphics[height=0.95\textheight]{UnsuitVsExtractor-2LedsGreen-Colour-02.eps}
185\caption{Uncalibrated pixels and pixels outside of the Gaussian distribution for a typical green pulse.}
186\label{fig:unsuited:2ledsgreen}
187\end{figure}
188
189\begin{figure}[htp]
190\centering
191\includegraphics[height=0.95\textheight]{UnsuitVsExtractor-23LedsBlue-Colour-00.eps}
192\caption{Uncalibrated pixels and pixels outside of the Gaussian distribution for a high-intensity blue pulse.}
193\label{fig:unsuited:23ledsblue}
194\end{figure}
195
196One can see that in general, big extraction windows raise the
197number of un-calibrated pixels and are thus less stable. Especially for the very low-intensity
198\textit{\bf 1Led\,UV}-pulse, the big extraction windows summing 8 or more slices, cannot calibrate more
199than 50\%
200of the inner pixels (fig.~\ref{fig:unsuited:1leduv}). This is an expected behavior since big windows
201add up more noise which in turn makes the search for the small signal more difficult.
202\par
203In general, one can also find that all ``sliding window''-algorithms (extractors \#17-32) discard
204less pixels than the corresponding ``fixed window''-ones (extractors \#1--16). The digital filter with
205the correct weights (extractors \#30-33) discards the least number of pixels and is also robust against
206slight modifications of its weights (extractors \#28--30). The robustness gets lost when the high-gain and
207low-gain weights are inverted (extractors \#31--39, see fig.~\ref{fig:unsuited:23ledsblue}).
208\par
209Also the ``spline'' algorithms on small
210windows (extractors \#23--25) discard less pixels than the previous extractors.
211\par
212It seems also that the spline algorithm extracting the amplitude of the signal produces an over-proportional
213number of excluded events in the low-gain. The same, however in a less significant manner, holds for
214the digital filter with high-low-gain inverted weights. The limit of stability with respect to
215changes in the pulse form seems to be reached, there.
216\par
217Concerning the numbers of outliers, one can conclude that in general, the numbers are very low never exceeding
2180.1\% except for the ampltiude-extracting spline which seems to mis-reconstruct a certain type of events.
219\par
220In conclusion, already this first test excludes all extractors with too large window sizes because
221they are not able to extract cleanly small signals produced by about 4 photo-electrons. Moreover,
222some extractors do not reproduce the signals as expected in the low-gain.
223
224%The excluded extractors are:
225%\begin{itemize}
226%\item: MExtractFixedWindow Nr. 3--5
227%\item: MExtractFixedWindowSpline Nr. 6--11 (all)
228%\item: MExtractFixedWindowPeakSearch Nr. 14--16
229%\item: MExtractTimeAndChargeSlidingWindow Nr. 21--22
230%\item: MExtractTimeAndChargeSpline Nr. 23 and 27
231%\end{itemize}
232
233\clearpage
234
235%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
236
237\subsection{Number of Photo-Electrons \label{sec:photo-electrons}}
238
239Assuming that the readout chain adds only negligible noise to the one
240introduced by the photo-multiplier itself, one can make the assumption that the variance of the
241true signal $S$ is the amplified Poisson variance of the number of photo-electrons,
242multiplied with the excess noise of the photo-multiplier which itself is
243characterized by the excess-noise factor $F$.
244
245\begin{equation}
246Var(S) = F^2 \cdot Var(N_{phe}) \cdot \frac{<S>^2}{<N_{phe}>^2}
247\label{eq:excessnoise}
248\end{equation}
249
250After introducing the effect of the night-sky background (eq.~\ref{eq:rmssubtraction})
251in formula~\ref{eq:excessnoise} and assuming that the variance of the number of photo-electrons is equal
252to the mean number of photo-electrons (because of the Poisson distribution),
253one obtains an expression to retrieve the mean number of photo-electrons impinging on the pixel from the
254mean extracted signal $<\widehat{S}>$,
255its variance $Var(\widehat{S})$ and the RMS of the extracted signal obtained from
256pure pedestal runs $R$ (see section~\ref{sec:ffactor}):
257
258\begin{equation}
259<N_{phe}> \approx F^2 \cdot \frac{<\widehat{S}>^2}{Var(\widehat{S}) - R^2}
260\label{eq:pheffactor}
261\end{equation}
262
263In theory, eq.~\ref{eq:pheffactor} must not depend on the extractor! Effectively, we will use it to test the
264quality of our extractors by requiring that a valid extractor yields the same number of photo-electrons
265for all pixels of a same type and does not deviate from the number obtained with other extractors.
266As the camera is flat-fielded, but the number of photo-electrons impinging on an inner and an outer pixel is
267different, we also use the ratio of the mean numbers of photo-electrons from the outer pixels to the one
268obtained from the inner pixels as a test variable. In the ideal case, it should always yield its central
269value of about 2.6$\pm$0.1~\cite{michele-diploma}.
270\par
271In our case, there is an additional complication due to the fact that the green and blue coloured light pulses
272show secondary pulses which destroy the Poisson behaviour of the number of photo-electrons. We will
273have to split our sample of extractors into those being affected by the secondary pulses and those
274being immune to this effect.
275\par
276Figures~\ref{fig:phe:5ledsuv},~\ref{fig:phe:1leduv},~\ref{fig:phe:2ledsgreen}~and~\ref{fig:phe:23ledsblue} show
277some of the obtained results. Although one can see a rather good stability for the standard
278{\textit{\bf 5\,Leds\,UV}}\ pulse, except for the extractors {\textit{\bf MExtractFixedWindowPeakSearch}}, initialized
279with an extraction window of 2 slices and {\textit{\bf MExtractTimeAndChargeDigitalFilter}}, initialized with
280an extraction window of 4 slices (extractor \#29).
281\par
282There is a considerable difference for all shown non-standard pulses. Especially the pulses from green
283and blue LEDs
284show a clear dependency of the number of photo-electrons on the extraction window. Only the largest
285extraction windows seem to catch the entire range of (jittering) secondary pulses and get the ratio
286of outer vs. inner pixels right. However, they (obviously) over-estimate the number of photo-electrons
287in the primary pulse.
288\par
289The strongest discrepancy is observed in the low-gain extraction (fig.~\ref{fig:phe:23ledsblue}) where all
290fixed window extractors with too small extraction windows fail to reconstruct the correct numbers.
291This has to do with the fact that
292the fixed window extractors fail to do catch a significant part of the (larger) pulse because of the
2931~FADC slice event-to-event jitter.
294
295
296\begin{figure}[htp]
297\centering
298\includegraphics[height=0.92\textheight]{PheVsExtractor-5LedsUV-Colour-13.eps}
299\caption{Number of photo-electrons from a typical, not saturating calibration pulse of colour UV,
300reconstructed with each of the tested signal extractors.
301The first plots shows the number of photo-electrons obtained for the inner pixels, the second one
302for the outer pixels and the third shows the ratio of the mean number of photo-electrons for the
303outer pixels divided by the mean number of photo-electrons for the inner pixels. Points
304denote the mean of all not-excluded pixels, the error bars their RMS.}
305\label{fig:phe:5ledsuv}
306\end{figure}
307
308\begin{figure}[htp]
309\centering
310\includegraphics[height=0.92\textheight]{PheVsExtractor-1LedUV-Colour-04.eps}
311\caption{Number of photo-electrons from a typical, very low-intensity calibration pulse of colour UV,
312reconstructed with each of the tested signal extractors.
313The first plots shows the number of photo-electrons obtained for the inner pixels, the second one
314for the outer pixels and the third shows the ratio of the mean number of photo-electrons for the
315outer pixels divided by the mean number of photo-electrons for the inner pixels. Points
316denote the mean of all not-excluded pixels, the error bars their RMS.}
317\label{fig:phe:1leduv}
318\end{figure}
319
320\begin{figure}[htp]
321\centering
322\includegraphics[height=0.92\textheight]{PheVsExtractor-2LedsGreen-Colour-02.eps}
323\caption{Number of photo-electrons from a typical, not saturating calibration pulse of colour green,
324reconstructed with each of the tested signal extractors.
325The first plots shows the number of photo-electrons obtained for the inner pixels, the second one
326for the outer pixels and the third shows the ratio of the mean number of photo-electrons for the
327outer pixels divided by the mean number of photo-electrons for the inner pixels. Points
328denote the mean of all not-excluded pixels, the error bars their RMS.}
329\label{fig:phe:2ledsgreen}
330\end{figure}
331
332
333\begin{figure}[htp]
334\centering
335\includegraphics[height=0.92\textheight]{PheVsExtractor-23LedsBlue-Colour-00.eps}
336\caption{Number of photo-electrons from a typical, high-gain saturating calibration pulse of colour blue,
337reconstructed with each of the tested signal extractors.
338The first plots shows the number of photo-electrons obtained for the inner pixels, the second one
339for the outer pixels and the third shows the ratio of the mean number of photo-electrons for the
340outer pixels divided by the mean number of photo-electrons for the inner pixels. Points
341denote the mean of all not-excluded pixels, the error bars their RMS.}
342\label{fig:phe:23ledsblue}
343\end{figure}
344
345One can see that all extractors using a large window belong to the class of extractors being affected
346by the secondary pulses, except for the digital filter. The only exception to this rule is the digital filter
347which - despite of its 6 slices extraction window - seems to filter out all the secondary pulses.
348\par
349The extractor {\textit{\bf MExtractFixedWindowPeakSearch}} at low extraction windows apparently yields chronically low
350numbers of photo-electrons. This is due to the fact that the decision to fix the extraction window is
351made sometimes by an inner pixel and sometimes by an outer one since the camera is flat-fielded and the
352pixel carrying the largest non-saturated peak-search window is more or less found by a random signal
353fluctuation. However, inner and outer pixels have a systematic offset of about 0.5 to 1 FADC slices.
354Thus, the extraction fluctuates artificially for one given channel which results in a systematically
355large variance and thus in a systematically low reconstructed number of photo-electrons. This test thus
356excludes the extractors \#11--13.
357\par
358Moreover, one can see that the extractors applying a small fixed window do not get the ratio of
359photo-electrons correctly between outer to inner pixels for the green and blue pulses.
360\par
361The extractor {\textit{\bf MExtractTimeAndChargeDigitalFilter}} seems to be stable against modifications in the
362exact form of the weights in the high-gain readout channel since all applied weights yield about
363the same number of photo-electrons and the same ratio of outer vs. inner pixels. This statement does not
364hold any more for the low-gain, as can be seen in figure~\ref{fig:phe:23ledsblue}. There, the application
365of high-gain weights to the low-gain signal (extractors \#34--39) produces a too low number of photo-electrons
366and also a too low ratio of outer vs. inner pixels.
367\par
368All sliding window and spline algorithms yield a stable ratio of outer vs. inner pixels in the low-gain,
369however the effect of raising the number of photo-electrons with the extraction window is very pronounced.
370Note that in figure~\ref{fig:phe:23ledsblue}, the number of photo-electrons rises by about a factor 1.4,
371which is slightly higher than in the case of the high-gain channel (figure~\ref{fig:phe:2ledsgreen}).
372\par
373Concluding, there is no fixed window extractor yielding the correct number of photo-electrons
374for the low-gain, except for the largest extraction window of 8 and 10 low-gain slices.
375Either the number of photo-electrons itself is wrong or the ratio of outer vs. inner pixels is
376not correct. All sliding window algorithms seem to reproduce the correct numbers if one takes into
377account the after-pulse behaviour of the light pulser itself. The digital filter seems to be
378unstable against exchanging the pulse form to match the slimmer high-gain pulses, though.
379
380\par
381\ldots {\textit{\bf EXCLUDED : CW4, UV4 No stability High-gain vs. LoGain}}
382\par
383
384\subsection{Linearity Tests}
385
386In this section, we test the lineary of the extractors. As the photo-multiplier and the subsequent
387optical transmission devices~\cite{david} is a linear device over a
388wide dynamic range, the number of photo-electrons per charge has to remain constant over the tested
389linearity region. We will show here only examples of extractors which were not already excluded in the
390previous section.
391\par
392A first test concerns the stability of the conversion factor: mean number of averaged photo-electrons
393per FADC counts over the
394tested intensity region. A much more detailed investigation on the linearity will be shwon in a
395separate TDAS~\cite{tdas-calibration}.
396
397
398\begin{figure}[htp]
399\centering
400\includegraphics[width=0.95\linewidth]{PheVsCharge-3.eps}
401\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
402exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
403A fixed window extractor on a window size of 6 high-gain and 6 low-gain slices has been used (extractor \#3). }
404\label{fig:linear:phevscharge3}
405\end{figure}
406
407\begin{figure}[htp]
408\centering
409\includegraphics[width=0.95\linewidth]{PheVsCharge-8.eps}
410\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
411exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
412A fixed window spline extractor on a window size of 6 high-gain and 6 low-gain slices has been used
413(extractor \#8). }
414\label{fig:linear:phevscharge8}
415\end{figure}
416
417\begin{figure}[htp]
418\centering
419\includegraphics[width=0.95\linewidth]{PheVsCharge-14.eps}
420\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
421exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
422A fixed window peak search extractor on a window size of 6 high-gain and 6 low-gain slices has been used
423(extractor \#14). }
424\label{fig:linear:phevscharge14}
425\end{figure}
426
427\begin{figure}[htp]
428\centering
429\includegraphics[width=0.95\linewidth]{PheVsCharge-20.eps}
430\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
431exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
432A sliding window extractor on a window size of 6 high-gain and 6 low-gain slices has been used
433 (extractor \#20). }
434\label{fig:linear:phevscharge20}
435\end{figure}
436
437\begin{figure}[htp]
438\centering
439\includegraphics[width=0.95\linewidth]{PheVsCharge-25.eps}
440\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
441exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
442An integrating spline extractor on a sliding window and a window size of 2 high-gain and 3 low-gain slices
443has been used (extractor \#25). }
444\label{fig:linear:phevscharge25}
445\end{figure}
446
447\begin{figure}[htp]
448\centering
449\includegraphics[width=0.95\linewidth]{PheVsCharge-27.eps}
450\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
451exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
452An integrating spline extractor on a sliding window and a window size of 6 high-gain and 7 low-gain slices
453has been used (extractor \#27). }
454\label{fig:linear:phevscharge27}
455\end{figure}
456
457\begin{figure}[htp]
458\centering
459\includegraphics[width=0.95\linewidth]{PheVsCharge-30.eps}
460\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
461exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
462A digital filter extractor on a window size of 6 high-gain and 6 low-gain slices has been used
463with UV-weights (extractor \#30). }
464\label{fig:linear:phevscharge30}
465\end{figure}
466
467\begin{figure}[htp]
468\centering
469\includegraphics[width=0.95\linewidth]{PheVsCharge-31.eps}
470\caption{Example of a the development of the conversion factor FADC counts to photo-electrons for two
471exemplary inner pixels (upper plots) and two exemplary outer ones (lower plots).
472A digital filter extractor on a window size of 4 high-gain and 4 low-gain slices has been used
473 (extractor \#31). }
474\label{fig:linear:phevscharge31}
475\end{figure}
476
477\clearpage
478
479\subsection{Time Resolution}
480
481The extractors \#17--32 are able to extract also the arrival time of each pulse. The calibration
482delivers a fast-rising pulse, uniform over the camera in signal size and time.
483We estimate the time-uniformity to better
484than 300\,ps, a limit due to the different travel times of the light between inner and outer parts of the
485camera. Since the calibraion does not permit a precise measurement of the absolute arrival time, we measure
486the relative arrival time for every channel with respect to a reference channel (usually pixel Nr.\,1):
487
488\begin{equation}
489\delta t_i = t_i - t_1
490\end{equation}
491
492where $t_i$ denotes the reconstructed arrival time of pixel number $i$ and $t_1$ the reconstructed
493arrival time of the reference pixel nr. 1 (software numbering). For one calibration run, one can then fill
494histograms of $\delta t_i$ for each pixel and fit them to the expected Gaussian distribution. The fits
495yield a mean $\mu(\delta t_i)$, comparable to
496systematic offsets in the signal delay, and a sigma $\sigma(\delta t_i)$, a measure of the
497combined time resolutions of pixel $i$ and pixel 1. Assuming that the PMTs and readout channels are
498of a same kind, we obtain an approximate absolute time resolution of pixel $i$ by:
499
500\begin{equation}
501t^{res}_i \approx \sigma(\delta t_i)/sqrt(2)
502\end{equation}
503
504Figures~\ref{fig:reltimesinner10leduv} and~\ref{fig:reltimesouter10leduv} show distributions of $\delta t_i$
505for
506one typical inner pixel and one typical outer pixel and a non-saturating calibration pulse of UV-light,
507obtained with three different extractors. One can see that the first two yield a Gaussian distribution
508to a good approximation, whereas the third extractor shows a three-peak structure and cannot be fitted.
509We discarded that particular extractor for this reason.
510
511\begin{figure}[htp]
512\centering
513\includegraphics[width=0.3\linewidth]{RelArrTime_Pixel97_10LedUV_Extractor32.eps}
514\includegraphics[width=0.32\linewidth]{RelArrTime_Pixel97_10LedUV_Extractor23.eps}
515\includegraphics[width=0.32\linewidth]{RelArrTime_Pixel97_10LedUV_Extractor17.eps}
516\caption{Example of a two distributions of relative arrival times of an inner pixel with respect to
517the arrival time of the reference pixel Nr. 1. The left plot shows the result using the digital filter
518 (extractor \#32), the central plot shows the result obtained with the half-maximum of the spline and the
519right plot the result of the sliding window with a window size of 2 FADC slices (extractor \#17). A
520medium sized UV-pulse (10Leds UV) has been used which does not saturate the high-gain readout channel.}
521\label{fig:reltimesinner10leduv}
522\end{figure}
523
524\begin{figure}[htp]
525\centering
526\includegraphics[width=0.31\linewidth]{RelArrTime_Pixel400_10LedUV_Extractor32.eps}
527\includegraphics[width=0.31\linewidth]{RelArrTime_Pixel400_10LedUV_Extractor23.eps}
528\includegraphics[width=0.31\linewidth]{RelArrTime_Pixel400_10LedUV_Extractor17.eps}
529\caption{Example of a two distributions of relative arrival times of an outer pixel with respect to
530the arrival time of the reference pixel Nr. 1. The left plot shows the result using the digital filter
531 (extractor \#32), the central plot shows the result obtained with the half-maximum of the spline and the
532right plot the result of the sliding window with a window size of 2 FADC slices (extractor \#17). A
533medium sized UV-pulse (10Leds UV) has been used which does not saturate the high-gain readout channel.}
534\label{fig:reltimesouter10leduv}
535\end{figure}
536
537Figures~\ref{fig:reltimesinner10ledsblue} and~\ref{fig:reltimesouter10ledsblue} show distributions of
538$<\delta t_i>$ for
539one typical inner and one typical outer pixel and a high-gain-saturating calibration pulse of blue-light,
540obtained with two different extractors. One can see that the first (extractor \#23) yields a Gaussian
541distribution to a good approximation.
542
543\begin{figure}[htp]
544\centering
545\includegraphics[width=0.31\linewidth]{RelArrTime_Pixel97_10LedBlue_Extractor23.eps}
546\includegraphics[width=0.31\linewidth]{RelArrTime_Pixel97_10LedBlue_Extractor32.eps}
547\caption{Example of a two distributions of relative arrival times of an inner pixel with respect to
548the arrival time of the reference pixel Nr. 1. The left plot shows the result using the half-maximum of the spline (extractor \#23), the right plot shows the result obtained with the digital filter
549(extractor \#32). A
550medium sized Blue-pulse (10Leds Blue) has been used which saturates the high-gain readout channel.}
551\label{fig:reltimesinner10ledsblue}
552\end{figure}
553
554
555
556\begin{figure}[htp]
557\centering
558\includegraphics[width=0.31\linewidth]{RelArrTime_Pixel400_10LedBlue_Extractor23.eps}
559\includegraphics[width=0.31\linewidth]{RelArrTime_Pixel400_10LedBlue_Extractor32.eps}
560\caption{Example of a two distributions of relative arrival times of an outer pixel with respect to
561the arrival time of the reference pixel Nr. 1. The left plot shows the result using the half-maximum of the spline (extractor \#23), the right plot shows the result obtained with the digital filter
562(extractor \#32). A
563medium sized Blue-pulse (10Leds Blue) has been used which saturates the high-gain readout channel.}
564\label{fig:reltimesouter10ledsblue}
565\end{figure}
566
567%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
568
569\begin{figure}[htp]
570\centering
571\includegraphics[width=0.95\linewidth]{UnsuitTimeVsExtractor-5LedsUV-Colour-12.eps}
572\caption{Reconstructed arrival time resolutions from a typical, not saturating calibration pulse
573of colour UV, reconstructed with each of the tested arrival time extractors.
574The first plots shows the time resolutions obtained for the inner pixels, the second one
575for the outer pixels. Points
576denote the mean of all not-excluded pixels, the error bars their RMS.}
577\label{fig:time:5ledsuv}
578\end{figure}
579
580\begin{figure}[htp]
581\centering
582\includegraphics[width=0.95\linewidth]{UnsuitTimeVsExtractor-1LedUV-Colour-04.eps}
583\caption{Reconstructed arrival time resolutions from the lowest intensity calibration pulse
584of colour UV (carrying a mean number of 4 photo-electrons),
585reconstructed with each of the tested arrival time extractors.
586The first plots shows the time resolutions obtained for the inner pixels, the second one
587for the outer pixels. Points
588denote the mean of all not-excluded pixels, the error bars their RMS.}
589\label{fig:time:1leduv}
590\end{figure}
591
592\begin{figure}[htp]
593\centering
594\includegraphics[width=0.95\linewidth]{UnsuitTimeVsExtractor-2LedsGreen-Colour-02.eps}
595\caption{Reconstructed arrival time resolutions from a typical, not saturating calibration pulse
596of colour Green, reconstructed with each of the tested arrival time extractors.
597The first plots shows the time resolutions obtained for the inner pixels, the second one
598for the outer pixels. Points
599denote the mean of all not-excluded pixels, the error bars their RMS.}
600\label{fig:time:2ledsgreen}
601\end{figure}
602
603\begin{figure}[htp]
604\centering
605\includegraphics[width=0.95\linewidth]{UnsuitTimeVsExtractor-23LedsBlue-Colour-00.eps}
606\caption{Reconstructed arrival time resolutions from the highest intensity calibration pulse
607of colour blue, reconstructed with each of the tested arrival time extractors.
608The first plots shows the time resolutions obtained for the inner pixels, the second one
609for the outer pixels. Points
610denote the mean of all not-excluded pixels, the error bars their RMS.}
611\label{fig:time:23ledsblue}
612\end{figure}
613
614%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
615
616\begin{figure}[htp]
617\centering
618\includegraphics[width=0.95\linewidth]{TimeResExtractor-5LedsUV-Colour-12.eps}
619\caption{Reconstructed arrival time resolutions from a typical, not saturating calibration pulse
620of colour UV, reconstructed with each of the tested arrival time extractors.
621The first plots shows the time resolutions obtained for the inner pixels, the second one
622for the outer pixels. Points
623denote the mean of all not-excluded pixels, the error bars their RMS.}
624\label{fig:time:5ledsuv}
625\end{figure}
626
627\begin{figure}[htp]
628\centering
629\includegraphics[width=0.95\linewidth]{TimeResExtractor-1LedUV-Colour-04.eps}
630\caption{Reconstructed arrival time resolutions from the lowest intensity calibration pulse
631of colour UV (carrying a mean number of 4 photo-electrons),
632reconstructed with each of the tested arrival time extractors.
633The first plots shows the time resolutions obtained for the inner pixels, the second one
634for the outer pixels. Points
635denote the mean of all not-excluded pixels, the error bars their RMS.}
636\label{fig:time:1leduv}
637\end{figure}
638
639\begin{figure}[htp]
640\centering
641\includegraphics[width=0.95\linewidth]{TimeResExtractor-2LedsGreen-Colour-02.eps}
642\caption{Reconstructed arrival time resolutions from a typical, not saturating calibration pulse
643of colour Green, reconstructed with each of the tested arrival time extractors.
644The first plots shows the time resolutions obtained for the inner pixels, the second one
645for the outer pixels. Points
646denote the mean of all not-excluded pixels, the error bars their RMS.}
647\label{fig:time:2ledsgreen}
648\end{figure}
649
650\begin{figure}[htp]
651\centering
652\includegraphics[width=0.95\linewidth]{TimeResExtractor-23LedsBlue-Colour-00.eps}
653\caption{Reconstructed arrival time resolutions from the highest intensity calibration pulse
654of colour blue, reconstructed with each of the tested arrival time extractors.
655The first plots shows the time resolutions obtained for the inner pixels, the second one
656for the outer pixels. Points
657denote the mean of all not-excluded pixels, the error bars their RMS.}
658\label{fig:time:23ledsblue}
659\end{figure}
660
661
662\begin{figure}[htp]
663\centering
664\includegraphics[width=0.95\linewidth]{TimeResVsCharge-Area-21.eps}
665\caption{Reconstructed mean arrival time resolutions as a function of the extracted mean number of
666photo-electrons for the weighted sliding window with a window size of 8 FADC slices (extractor \#21).
667Error bars denote the
668spread (RMS) of the time resolutions over the investigated channels.
669The marker colours show the applied
670pulser colour, except for the last (green) point where all three colours were used.}
671\label{fig:time:dep20}
672\end{figure}
673
674\begin{figure}[htp]
675\centering
676\includegraphics[width=0.95\linewidth]{TimeResVsCharge-Area-24.eps}
677\caption{Reconstructed mean arrival time resolutions as a function of the extracted mean number of
678photo-electrons for the half-maximum searching spline (extractor \#23). Error bars denote the
679spread (RMS) of the time resolutions over the investigated channels.
680The marker colours show the applied
681pulser colour, except for the last (green) point where all three colours were used.}
682\label{fig:time:dep23}
683\end{figure}
684
685
686\begin{figure}[htp]
687\centering
688\includegraphics[width=0.95\linewidth]{TimeResVsCharge-Area-30.eps}
689\caption{Reconstructed mean arrival time resolutions as a function of the extracted signal
690for the digital filter with UV weights and 6 slices (extractor \#30). Error bars denote the
691spread (RMS) of the time resolutions over the investigated channels.
692The marker colours show the applied
693pulser colour, except for the last (green) point where all three colours were used.}
694\label{fig:time:dep30}
695\end{figure}
696
697
698\begin{figure}[htp]
699\centering
700\includegraphics[width=0.95\linewidth]{TimeResVsCharge-Area-31.eps}
701\caption{Reconstructed mean arrival time resolutions as a function of the extracted signal
702for the digital filter with UV weights and 4 slices (extractor \#32). Error bars denote the
703spread (RMS) of the time resolutions over the investigated channels.
704The marker colours show the applied
705pulser colour, except for the last (green) point where all three colours were used.}
706\label{fig:time:dep32}
707\end{figure}
708
709%%% Local Variables:
710%%% mode: latex
711%%% TeX-master: "MAGIC_signal_reco"
712%%% End:
Note: See TracBrowser for help on using the repository browser.